WorldWideScience
1

Calcification of subcutaneously implanted type I collagen sponges. Effects of formaldehyde and glutaraldehyde pretreatments.  

UK PubMed Central (United Kingdom)

Although collagen-containing implants are widely used in various surgical applications, there has been relatively little attention paid to the possibility that this type of biomaterial may undergo pathologic...Full Text Available

1986-01-01

3

Excessive bleeding in the floor of the mouth after endosseus implant placement: a report of two cases  

British Library Electronic Table of Contents (United Kingdom)

Placement of dental implants in the interforaminal region of the edentulous mandible is considered a safe and routine surgical procedure. Hemorrhage in the floor of the mouth has been reported as a rare, potentially life-threatening complication related to the placement of implants in this region. In this case report the authors present an immediate and a delayed case of massive bleeding in the floor of the mouth after implant placement. This highly vascularized region is vulnerable and bleeding can be induced easily by instrumentation, causing a vascular trauma, usually by perforation of lingual periostium. In almost all cases the expanding hematoma formation starts during surgery. The effect of the vasoconstrictive agent in the local anesthesic combined with an injury of the lingual arte...

2010-01-01

4

Kenai River Salmon ... a Unique Resource in South-Central ...  

Science.gov (United States)

... Accession Number : ADA323711. Title : Kenai River Salmon ... a Unique Resource in South-Central Alaska. Descriptive ...

5

Reversible downregulation of endocrine and germinative testicular function (hormonal castration) in the dog with the GnRH-Agonist Azagly-Nafarelin as a removable implant "Gonazon"; a preclinical trial  

British Library Electronic Table of Contents (United Kingdom)

Downregulation of anterior pituitary GnRH-receptors by application of a slow release GnRH-implant offers an effective and reversible alternative to surgical castration of the male dog. Aim of the present study was to test the efficacy and the underlying mechanisms of a new non-biodegradable controlled-release device implant (Gonazon, Intervet, containing 18.5mg of the GnRH-agonist Azagly-Nafarelin). Eight male beagle dogs were implanted s.c. at the para-umbilical region. In four dogs implant removal was after 180 days (group 1), in the other four dogs after 365 days (group 2). Eleven weeks after implantation availability of LH was reduced (p<0.0001) by 70%. After an initial increase lasting for about 4 days, testosterone (T) and estradiol (E2) concentrations decreased (p<0.0001) to basal l...

2009-01-01

7

Combined bony closure of oroantral fistula and sinus lift with mandibular bone grafts for subsequent dental implant placement  

British Library Electronic Table of Contents (United Kingdom)

Sinus lifting and reconstruction of localized alveolar defects are often required after closure of a large oroantral fistula (OAF) to allow for subsequent implant installation. This study describes a combined surgical technique that involves sinus lifting, bony closure, and reconstruction of the alveolar defect at the site of an OAF. The sinus membrane was reconstructed as a continuous layer by combining the residual sinus membrane with a rotated part of oral mucosa around the OAF. Autogenous bone from the chin and/or ramus was grafted into the prepared sinus space and alveolar defect, and the graft was covered by a buccal advancement flap. This technique was used to treat 8 patients who had large OAFs in the posterior maxillary region. The treatment was successful in all cases, and the te...

2011-01-01

8

Genetic Monitoring and Evaluation Program for Supplemented Populations of Salmon and Steelhead in the Snake River Basin, 1990-1991 Annual Report.  

Energy Technology Data Exchange (ETDEWEB)

This is the first report of research for an ongoing study to evaluate the genetic effects of using hatchery-reared fish to supplement natural populations of chinook salmon and steelhead in the Snake River Basin.

1991-08-01

9

Plasma-based ion implantation and deposition: A review of physics,technology, and applications  

Energy Technology Data Exchange (ETDEWEB)

After pioneering work in the 1980s, plasma-based ion implantation (PBII) and plasma-based ion implantation and deposition (PBIID) can now be considered mature technologies for surface modification and thin film deposition. This review starts by looking at the historical development and recalling the basic ideas of PBII. Advantages and disadvantages are compared to conventional ion beam implantation and physical vapor deposition for PBII and PBIID, respectively, followed by a summary of the physics of sheath dynamics, plasma and pulse specifications, plasma diagnostics, and process modeling. The review moves on to technology considerations for plasma sources and process reactors. PBII surface modification and PBIID coatings are applied in a wide range of situations. They include the by-now traditional tribological applications of reducing wear and corrosion through the formation of hard, tough, smooth, low-friction and ...

2005-05-16

11

Multielement determination of major-to-ultratrace elements in salmon egg by ICP-AES and ICP-MS  

Energy Technology Data Exchange (ETDEWEB)

The multielement determination of major-to-ultratrace elements in salmon egg was carried out by ICP-AES and ICP-MS. First, salmon eggs (30 eggs used) were digested with conc. nitric acid and 60% perchloric acid by heating almost to dryness repeatedly. Finally, the residues of salmon eggs were dissolved in 1 M nitric acid and the sample solutions were analyzed by ICP-AES and ICP-MS. About 40 elements could be determined over the concentration range in 9 orders of magnitude. The concentrations of bio-essential elements, such as Zn, Fe, and Cu, in salmon egg were 10-100 times higher than those in human blood serum. In addition, the major-to-ultratrace elements in cell cytoplasm and cell membrane were separately determined in a similar manner to those in whole egg cell. The concentrations of most bio-essential elements were higher in cell cytoplasm than in cell membrane, while those of Fe and Cu were higher ...

2002-04-01

12

Prevention of Mechanical Failures in Implanted Spinal Cord Stimulation Systems  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction. Spinal cord stimulation (SCS) is an effective procedure for the treatment of neuropathic extremity pain, with success rates approaching 70%. However, mechanical failures, including breakage and migration, can significantly limit the long-term effectiveness of SCS. A systematic analysis of surgical techniques was undertaken by a consensus group, coupled with extensive in vivo and in vitro biomechanical testing of system components. Methods. A computer model based on morphometric data was used to predict movement in a standard SCS system between an anchored lead and pulse generator placed in various locations. These displacements were then used to determine a realistic range of forces exerted on components of the SCS system. Laboratory fixtures were constructed to subj...

2006-01-01

13

Snake River Fall Chinook Salmon Life History Investigations, Annual Report 2008.  

Energy Technology Data Exchange (ETDEWEB)

This study was initiated to provide empirical data and analyses on the dam passage timing, travel rate, survival, and life history variation of fall Chinook salmon that are produced in the Clearwater River. The area of interest for this study focuses on the lower four miles of the Clearwater River and its confluence with the Snake River because this is an area where many fish delay their seaward migration. The goal of the project is to increase our understanding of the environmental and biological factors that affect juvenile life history of fall Chinook salmon in the Clearwater River. The following summaries are provided for each of the individual chapters in this report.

2009-09-15

14

1998 evaluation of juvenile fall chinook salmon stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the second year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fish species, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1998 field season.

15

Inlay-onlay grafting for three-dimensional reconstruction of the posterior atrophic maxilla with mandibular bone  

British Library Electronic Table of Contents (United Kingdom)

This prospective study describes and evaluates a surgical approach for 3D reconstruction of the posterior maxilla with autogenous mandibular bone in 16 patients (mean age 51 years). Bone blocks were harvested from the mandible and used as lateral or vertical block grafts (onlay); they were also partially milled and used for sinus elevation (inlay). In 4 cases, anorganic bovine bone was added at the periphery of the blocks. 4 months after grafting, implants were placed in a second operation and loaded after 12 weeks. Lateral and vertical augmentations were measured immediately after grafting and at re-entry for implant placement. Mean lateral augmentation performed was 5.5mm, reduced to 4.3mm (p<0.01) after 4 months' healing. Mean vertical augmentation was 3.2mm, reduced to 2.1mm (p<0.01) a...

2010-01-01

18

Treatment of peripheral aneurysms by dacron-covered nitinol stents; Behandlung arterieller Aneurysmen der Becken-Bein-Gefaesse mittels Dacron-ummantelter Nitinol-Stents  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. ...

1998-03-01

20

Exxon Valdez oil spill. State/federal natural resource damage assessment final report. Sockeye salmon overescapement. Fish/shellfish study number 27  

Energy Technology Data Exchange (ETDEWEB)

The authors examined the effects of large escapements of sockeye salmon in to the Kenai River and into Red and Akalura Lakes on Kodiak Island. Estimated smolt numbers outmigrating from the Kenai River decreased from 30 million in 1989 to under 500,000 in 1992. Decreased overwintering survival of age-0 juvenile sockeye salmon rearing in Skilak and Kenai lakes is the major contributor to this decline. Preliminary examination of limnological data from Skilak and Kenai Lakes provided no obvious explanation for this major decline in winter survival of juvenile sockeye. Due to differences in diel vertical migration of zooplankton among glacial lakes on the Kenai Peninsula with varying planktivores levels, the authors hypothesize that behavioral changes of zooplankton induced by predation may be a major contributor to the juvenile sockeye decline.

1993-07-01

21

Oxygen Implanted Materials  

International Science & Technology Center (ISTC)

Development of Oxygen Ion-Implanted Collector materials for Thermal Emission Converters of Thermal Energy into the Electric One.

22

Control of Phosphorus Transient Enhanced Diffusion using Co-implantation  

CERN Document Server

Control of Phosphorus Transient Enhanced Diffusion using Co-implantation

2006-01-01

23

Some medical applications of thermomechanically treated titanium nickelide  

Energy Technology Data Exchange (ETDEWEB)

An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first publication the ...

2001-11-01

24

cDNA cloning and sequence analysis of preproendothelin-1 (PPET-1) from salmon, Oncorhynchus keta.  

Science.gov (United States)

The presence of endothelin (ET)-like immunoreactivity and the cardiovascular effects of mammalian ET-1 in fish have been reported. To identify ET-related peptides in fish, we screened the cDNA library of the salmon (Oncorhynchus keta) stomach by means of rapid amplification of cDNA ends, and we cloned cDNAs encoding an ET-related peptide. The salmon ET-related sequence of 21 amino acids is identical to the trout ET-1 peptide recently purified from kidney specimens of Oncorhynchus mykiss. The deduced amino acid sequence of salmon pre-proET-1 (PPET-1) comprises 244 amino acids, including a putative signal sequence and mature ET-1, as well as big ET-1 and ET-1-like sequences. This precursor, the first reported PPET-1 sequence for Salmoniformes, Teleostei, has low homology with the sequences of human, mouse, frog (Xenopus laevis), and zebrafish (Danio rerio) PPET-1 (26%, 29%, 24%, and 39%, respectively). PMID:16740985

2006-06-01

25

Juvenile salmon with high standard metabolic rates have higher energy costs but can process meals faster  

UK PubMed Central (United Kingdom)

Basal or standard metabolic rate (SMR) has been found to exhibit substantial intraspecific variation in a range of taxa, but the consequences of this variation are little understood. Here we explore...Full Text Available

2009-06-07

26

Genotype-specific responses in Atlantic salmon (Salmo salar) subject to dietary fish oil replacement by vegetable oil: a liver transcriptomic analysis  

UK PubMed Central (United Kingdom)

BackgroundExpansion of aquaculture is seriously limited by reductions in fish oil (FO) supply for aquafeeds. Terrestrial alternatives such as vegetable oils (VO) have been investigated...Full Text Available

27

Desmozoon lepeophtherii n. gen., n. sp., (Microsporidia: Enterocytozoonidae) infecting the salmon louse Lepeophtheirus salmonis (Copepoda: Caligidae)  

UK PubMed Central (United Kingdom)

BackgroundA microsporidian was previously reported to infect the crustacean parasite, Lepeophtheirus salmonis (Krøyer, 1837) (Copepoda, Caligidae), on farmed...Full Text Available

28

2001 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach of the Columbia River. The evaluation, in the fifth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2001 field season.

29

2000 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the fourth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2000 field season.

30

1999 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River, annual report 1999.; ANNUAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the third year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1999 field season.

31

Organisation of care for Swedish patients with an implantable cardioverter defibrillator, a national survey  

British Library Electronic Table of Contents (United Kingdom)

Aim.- To describe the clinical aspects of implantable cardioverter defibrillators care in Sweden with focus on organisation, the role and education of nurses, patient information and education and areas in need of improvement. Background.- Implantable cardioverter defibrillators implantations have developed rapidly in recent years and are now an established arrhythmia treatment. The expanding indication for implantable cardioverter defibrillators implantation demands new competencies and resources in the implantable cardioverter defibrillators team members. Methods.- Participants were recruited among physicians and nurses in all of the hospitals implanting implantable cardioverter defibrillators (n-=-16). Data were collected by a questionnaire. Additionally, all written educational materia...

2011-01-01

32

Minimally Invasive Orthopedic Surgery: Arthroscopy  

UK PubMed Central (United Kingdom)

Arthroscopy, a minimally invasive alternative to standard open surgical techniques and now the most commonly performed orthopedic surgical procedure, was one of the greatest advances in orthopedic surgery...Full Text Available

2000-07-01

35

Ovarian Cancer  

Medline Plus

... opening the abdomen surgically. This surgery may be laparoscopic, using special scopes. It could also be an ...

37

Brief laboratory report: surgical drape flammability.  

Science.gov (United States)

Fires in the operating room continue to present a hazard to patients, at times with catastrophic and debilitating results. Recent data from closed claim files reveal oxygen, electrosurgical unit (ESU), and surgical drapes are common components of the fire triangle in the operating room. In this era of biotechnological sophistication, why are surgical drapes flammable? The purpose of this study was to test the flammability of different surgical drape materials and to determine the time to ignition using a bipolar ESU device in 21%, 35%, and 100% oxygen concentrations. Results show that regardless of oxygen concentration surgical drapes, when exposed to close contact with the ESU, are flammable. Time to ignition decreases with increasing concentrations of oxygen as expected. One of the surgical drapes tested was advertised to the hospital as nonflammable. Future research should focus ...

2006-10-01

38

Investigations into the early life history of naturally produced spring chinook salmon and summer steelhead in the Grande Ronde River Basin : annual report 2000 : project period 1 October 1999 to 30 November 2000.; ANNUAL  

International Nuclear Information System (INIS)

The authors determined migration timing and abundance of juvenile spring chinook salmon Oncorhynchus tshawytscha and juvenile steelhead/rainbow trout O. mykiss from three populations in the Grande Ronde River basin. Based on migration timing and abundance, two distinct life-history strategies of juvenile spring chinook and O.mykiss could be distinguished. An early migrant group left upper rearing areas from July through January with a peak in the fall. A late migrant group descended from upper rearing areas from February through June with a peak in the spring.

39

Injuries of the tibio-talar joint and preoperative planning. Verletzungen des oberen Sprunggelenks aus unfallchirurgischer Sicht  

Energy Technology Data Exchange (ETDEWEB)

The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with concomitant compartment ...

1991-12-01

40

High-field MR imaging in the follow-up of patients with valvular and composite tubular aortic prostheses  

International Nuclear Information System (INIS)

Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a thrombosed one) at the graft level. In one ...

41

Snake River Sockeye Salmon Habitat and Limnological Research; 1995 Annual Report.  

Energy Technology Data Exchange (ETDEWEB)

This report contains studies which are part of the Bonneville Power Administration`s program to protect, mitigate, and enhance fish and wildlife affected by the development and operation of hydroelectric facilities on the Columbia River and its tributaries. Attention is focused on population monitoring studies in the Sawtooth Valley Lakes. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

1996-05-01

42

Osseointegration of zirconia implants: an SEM observation of the bone-implant interface  

UK PubMed Central (United Kingdom)

BackgroundThe successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics,...Full Text Available

43

Optical and Structural Characteristics of Heavily Boron-Implanted CdTe.  

Science.gov (United States)

Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. Various diagnostic techniques were used to assess the structural and electronic properties of these crystals in their as-implante...

1988-01-01

44

Music perception in cochlear implant users and its relationship with psychophysical capabilities  

UK PubMed Central (United Kingdom)

This article describes issues concerning music perception with cochlear implants, discusses why music perception is usually poor in cochlear implant users, reviews relevant data, and describes...Full Text Available

2008-01-01

45

Complications of NewColorIris implantation in phakic eyes: a review  

UK PubMed Central (United Kingdom)

Purpose:To provide a literature review of implant related complications from bilateral NewColorIris implantation (Kahn Medical Devices, Panama City, Panama).Methods:A...Full Text Available

2011-01-01

46

Evaluate Potential Means of Rebuilding Sturgeon Populations in the Snake River between Lower Granite and Hells Canyon Dams, 2000 Annual Report.  

Energy Technology Data Exchange (ETDEWEB)

The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This 2000 annual report covers the fourth year of sampling of this multi-year study. In 2000 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon rivers. The Snake River was sampled between Lower Granite Dam (rkm 174) and the mouth of the Salmon River (rkm 303), and the Salmon River was sampled from its mouth upstream to Hammer Creek (rkm 84). A total of 53,277 hours of setline effort and 630 hours of hook-and-line effort was employed in 2000. A total of 538 white sturgeon were captured and tagged in the Snake River and 25 in the ...

2003-03-01

47

Surgical approach for high-energy posterior tibial plateau fractures  

UK PubMed Central (United Kingdom)

Background:High-energy fractures of posterior tibial plateau always need surgical treatment. Generally, posterior fragments of these fractures could not be exposed and reduced...Full Text Available

2011-03-01

48

Progressive Management of Open Surgical Repair of Achilles Tendon Rupture  

UK PubMed Central (United Kingdom)

A 33-year-old man sustained an acute Achilles tendon rupture which was surgically repaired. Early nonweight-bearing range of motion and strengthening of the ankle and the repaired muscle unit was allowed...Full Text Available

1994-12-01

49

Mouth Opening During Sleep may be a Critical Predictor of Surgical Outcome after Uvulopalatopharyngoplasty for Obstructive Sleep Apnea  

UK PubMed Central (United Kingdom)

Study Objectives:To evaluate the value of mouth opening during sleep for predicting surgical outcomes after uvulopalatopharyngoplasty (UPPP).Methods:Retrospectively,...Full Text Available

2010-04-15

50

Accelerated surgical stay programs. A mechanism to reduce health care costs.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To increase cost-efficiency while maintaining the standard of medical care, an accelerated surgical stay program for patients having breast surgery was instituted. SUMMARY BACKGROUND DATA:...Full Text Available

1994-04-01

51

A Combination of Dual-mode 2,940 nm Er:YAG Laser Ablation with Surgical Excision for Treating Medium-sized Congenital Melanocytic Nevus  

UK PubMed Central (United Kingdom)

BackgroundThere are various treatment options for congenital melanocytic nevus (CMN), including surgical excision, dermabrasions, curettage, laser treatment, chemical peels and cryosurgery....Full Text Available

2009-05-01

52

Surgical Counter-Terrorism: Targeting Individuals as an ...  

Science.gov (United States)

... Tanzania, and the attack on the USS COLE. ... vis another has no bearing on the legality of the attack. If the person attacked is a combatant, the use of ...

2003-02-03

53

State of Surgery in Tropical Africa: A Review  

British Library Electronic Table of Contents (United Kingdom)

This is a review of recently published literature on surgery in tropical Africa. It presents the current state of surgical need and surgical practice on the continent. We discuss the enormous burden of surgical pathology (as far as it is known) and the access to and acceptability of surgery. We also describe the available facilities in terms of equipment and manpower. The study looked at the effects of the human immunodeficiency virus, the role of traditional healers, anesthesia, and the economics of surgery. Medical training and research are discussed, as are medical migration out of Africa and the concept of task shifting, where surgical procedures are performed by others when surgeons are not available. It closes with recommendations for involvement and action in this area of great glob...

2011-01-01

54

Correction of skeletal Class II-anterior deep bite and prominent chin by forced surgical rotation of the mandible  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this paper is to describe a technique of forced surgical rotation of the mandible used in skeletal Class II patients with deep bite and prominent chin. Posterior occlusal composite onlays combined with preoperative orthodontic treatment without anterior intrusion increase the posterior rotational component of the surgical mandibular advancement, when removed during operation. This manoeuvre allows for the surgical closure of the posterior open bite, while anteriorly the deep bite is opened. This technique avoids bimaxillary rotation surgery with dorsal impaction in mild to moderate cases. In any case, a chin setback osteotomy with compromised aesthetics can be avoided.

2010-01-01

55

Osseointegration of zirconia implants compared with titanium: an in vivo study  

UK PubMed Central (United Kingdom)

BackgroundTitanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental...Full Text Available

56

Neural Tissues from the Implanted Stem Cells  

International Science & Technology Center (ISTC)

Morphological, Electrophysiological and Behavioral Investigations of the Nervous Tissue Developed from the Embryonic Matrix Zone Cells of the Dorsolateral Walls of Lateral Ventricles, Implanted into the Lesioned Regions of the Adult Rat's Brain

57

Behavior of osteoblastic cells cultured on titanium and structured zirconia surfaces  

UK PubMed Central (United Kingdom)

BackgroundOsseointegration is crucial for the long-term success of dental implants and depends on the tissue reaction at the tissue-implant interface. Mechanical properties and biocompatibility...Full Text Available

58

Aphakic macular oedema following prosthetic lens implantation.  

UK PubMed Central (United Kingdom)

Fluorescein angiography of the iris was performed on patients with plastic lens implants with cystoid oedema of the macula, and the nature of the vascular changes was compared with controls provided...Full Text Available

1977-05-01

59

A clinician's guide to surgical fires. How they occur, how to prevent them, how to put them out.  

Science.gov (United States)

Surgical fires--fires that occur on or in a surgical patient--are a rare but devastating complication of surgical procedures. They can happen during almost any kind of operation and can have dire consequences for both the patient and the hospital. The risk of surgical fires can be minimized as long as everyone on the surgical team understands how fires start and what to do when they occur. It's important to recognize the interaction among ignition sources, oxidizers, and fuels--the three sides of the classic fire triangle. What's more, staff members need to be alert to "hidden" fire risks, such as unsuspected oxygen-enriched atmospheres and less-than-obvious fuels. They also need to be drilled in the correct steps for responding to fires. In this guide, we describe the elements of surgical fires, including the types of equipment and materials that make up each ...

2003-01-01

60

Evaluate Potential Means of Rebuilding Sturgeon Populations in the Snake River between Lower Granite and Hells Canyon Dams, 2001 Annual Report.  

Energy Technology Data Exchange (ETDEWEB)

The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This 2001 annual report covers the fifth year of sampling of this multi-year study. In 2001 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon rivers. The Snake River was sampled between Lower Granite Dam (rkm 174) and the mouth of the Salmon River (rkm 303), and the Salmon River was sampled from its mouth upstream to Hammer Creek (rkm 84). A total of 45,907 hours of setline effort and 186 hours of hook-and-line effort was employed in 2001. A total of 390 white sturgeon were captured and tagged in the Snake River and 12 in the ...

2003-03-01

61

Evaluate Potenial Means of Rebuilding Sturgeon Populations in the Snake River between Lower Granite and Hells Canyon Dams, 2002 Annual Report.  

Energy Technology Data Exchange (ETDEWEB)

The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This report presents a summary of results from the 1997-2002 Phase II data collection and represents the end of phase II. From 1997 to 2001 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon. A total of 1,785 white sturgeon were captured and tagged in the Snake River and 77 in the Salmon River. Since 1997, 25.8 percent of the tagged white sturgeon have been recaptured. Relative density of white sturgeon was highest in the free-flowing segment of the Snake River, with reduced densities of fish in Lower Granite Reservoir, and low densities the Salmon ...

2004-02-01

65

Pitting corrosion resistance of silicon-implanted stainless steels  

International Nuclear Information System (INIS)

The pitting corrosion resistance of three different types of stainless steel implanted with silicon is investigated using the potentiokinetic polarization technique. The specimens are tested in 3% NaCl and 0.1 N HCl solutions. Silicon ion implantation inhibits pitting corrosion of the steels in both aqueous media. The corrosion resistance depends on the silicon dose. Post implantation annealing only slightly alters the localized corrosion. (author).

66

Multi-functional Biocompatible Coatings  

International Science & Technology Center (ISTC)

Multi-functional Bioactive Nano-structured Coatings for Load-Bearing Implants

67

Modeling of defect-phosphorus pair diffusion in phosphorus-implanted silicon  

International Nuclear Information System (INIS)

The point-defect-impurity pair diffusion model proposed recently by Mulvaney and Richardson is adopted and modified to simulate the coupled diffusion of phosphorus and self-interstitials in phosphorus-implanted silicon. The assumption of implantation-induced, but empirically determined initial interstitial distributions of Gaussian shape allows a simulation of the net effect of transient enhanced diffusion. As a result an improved modeling of phosphorus diffusion in silicon is achieved for a broad range of ion-implantation and annealing conditions. (author).

73

Retrospective analysis of porcelain failures of metal ceramic crowns and fixed partial dentures supported by 729 implants in 152 patients: Patient-specific and implant-specific predictors of ceramic failure  

British Library Electronic Table of Contents (United Kingdom)

Statement of problem Porcelain fracture associated with an implant-supported, metal ceramic crown or fixed partial denture occurs at a higher rate than in tooth-supported restorations, according to the literature. Implant-specific and patient-specific causes of ceramic failure have not been fully evaluated. Purpose The purpose of this retrospective study was to evaluate the potential statistical predictors for porcelain fracture of implant-supported, metal ceramic restorations. Material and Methods Over a 6-month period, a consecutive series of patients having previously received implant-supported, metal ceramic fixed restorations were examined during periodic recall appointments. The number of supporting implants, number of dental units, type of restoration, date of prosthesis insertion, ...

2009-01-01

74

Electrical properties of focused-ion-beam boron-implanted silicon  

International Nuclear Information System (INIS)

Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).

75

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si{sup 2+}, 1.0-MeV He{sup +} and 340-keV H{sup +}) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted ...

2007-03-15

76

Effect of Al and Be ions pre-implantation on formation and growth of helium bubbles in SiC/SiC composites  

International Nuclear Information System (INIS)

The effect of Al and Be ions pre-implantation on microstructural change and, the formation and growth of He bubbles in SiC/SiC composite was investigated. Four kinds of ion implanted specimens were prepared with 100 appm Al, 1000 appm Al, 100 appm Be and 1000 appm Be implanted. No microstructural change was observed in the matrices and fibers of SiC/SiC composites implanted with Al or Be ions up to 1000 appm. The un-implanted and Al or Be pre-implanted SiC/SiC composites were simultaneously irradiated to 10 dpa using triple ion-beams (6.0-MeV Si"2"+, 1.0-MeV He"+ and 340-keV H"+) at 1000 deg. C. Helium bubbles were formed in every matrix and fiber irradiated by triple ion-beams. The size of He bubbles in the matrix was increased by implanting Al or Be ions and increased with increasing amount of implanted Al or Be ions. ...

2007-03-01

77

High current implantation of negative copper ions into silica glasses  

Energy Technology Data Exchange (ETDEWEB)

High-current implantation of Cu{sup {minus}} ions into silica glasses has been demonstrated using mA-class negative ion beams at 60 keV. Negative ion implantation has an advantage to alleviate specimen charging for insulating substrates and has attained high dose rates, up to 260 {micro}A/cm{sup 2}. Spherical Cu colloids form in the silica glasses without additional thermal annealing. Optical absorption and reflection of the implanted specimens vary with the current density, even at a fixed dose level. A beam-induced surface plasma may affect the high current implantation.

1997-12-01

78

Computed tomography of the mediastinal lesion  

Energy Technology Data Exchange (ETDEWEB)

Authors retrospectively analyzed the CT findings of mediastinal lesions in surgically or clinically confirmed 37 cases at Kosin Medical College during recent 4 years from September 1979 to August 1983. 1. Among 37 caes, malignant lymphoma were 7 cases, thymoma and vascular lesion or anomaly were 5 cases respectively, benign teratoma and tuberculous mediastinal lymphadenitis and neurogenic tumor were 4 cases respectively, pericardial cyst were 2 cases, bronchogenic cyst, non-specific cyst, pancreatic pseudocyst, mesothelioma, Bochdalek hernia was 1 case respectively. 2. The sex ratio between male and female was about 1 : 1 and the majority of the patients with malignant lymphoma and teratoma was under 20 years old. 3. CT findings of the each mediastinal lesion. 1) Primary mediastinal malignant lymphoma. (1) A large, matted, continuous and midline-crossing mass was observed in the superior and the anterior mediastinums in all cases. (2) In 3 cases, irregular lower ...

1984-09-15

79

XPS study of passive films formed on molybdenum-implanted austenitic stainless steels  

Energy Technology Data Exchange (ETDEWEB)

Austenitic stainless steels have been implanted with molybdenum ions (Mo[sup +], 100 keV, 2.5 x 10[sup 16] atoms cm[sup -2]). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of [approx] 1000 A with a maximum molybdenum concentration of [approx] 9 at.% Mo located at [approx] 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H[sub 2]SO[sub 4] have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted ...

1992-06-01

80

XPS study of passive films formed on molybdenum-implanted austenitic stainless steels  

International Nuclear Information System (INIS)

Austenitic stainless steels have been implanted with molybdenum ions (Mo"+, 100 keV, 2.5 x 10"1"6 atoms cm"-"2). The implanted material has been characterized by XPS and RBS. The implanted region has a thickness of #approx# 1000 A with a maximum molybdenum concentration of #approx# 9 at.% Mo located at #approx# 210 A from the surface. The effects of implanted molybdenum on the passivation of the alloy in 0.5 M H_2SO_4 have been investigated by electrochemistry and XPS. After XPS analysis the samples were transferred without exposure to air into a glove-box with an inert atmosphere. The electrochemical behaviour of the alloy is significantly modified by the implanted molybdenum. The major effect is that the activation peak disappears. A bilayer structure (outer hydroxide/inner oxide) of the passive film is observed for both the implanted and ...

1991-10-01

81

Corrosion behaviour of molybdenum-implanted stainless steel  

Energy Technology Data Exchange (ETDEWEB)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of ...

1990-01-01

82

Corrosion behaviour of molybdenum-implanted stainless steel  

International Nuclear Information System (INIS)

A low-molybdenum austenitic stainless steel (UNS S30100) has been surface implanted with molybdenum ions, using various doses of 50 keV and 140 keV ions at room temperature. It is found that in aqueous sulphate/chloride solutions similar to the constitution of sea-waters the implantation does not affect the potentiostatically-determined critical pitting potential, but does change the density and morphology of corrosion pits. Pitting initiation after the addition of chloride at a fixed potential indicates little change in the time for measurable current increase, but the rate of increase of the current is much lower for implanted material. Detailed examination using optical microscopy, scanning electron microscopy, transmission electron microscopy and selected area diffraction suggests that the pits produced in implanted material are hemispherical with smooth covers of unattacked alloy. The use of ...

1989-09-01

83

The characteristics of surface oxidation and corrosion resistance of nitrogen implanted zircaloy-4  

International Nuclear Information System (INIS)

This work is concerned with the development and application of ion implantation techniques for improving the corrosion resistance of zircaloy-4. The corrosion resistance in nitrogen implanted zircaloy-4 under a 120 keV nitrogen ion beam at an ion dose of 3 x 10"1"7 cm"-"2 depends on the implantation temperature. The characteristics of surface oxidation and corrosion resistance were analyzed with the change of implantation temperature. It is shown that as implantation temperature rises from 100 to 724 C, the colour of specimen surface changes from its original colour to light yellow at 100 C, golden at 175 C, pink at 300 C, blue at 440 C and dark blue at 550 C. As the implantation temperature goes above 640 C, the colour of surface changes to light black, and the surface becomes a little rough. The corrosion resistance of zircaloy-4 implanted ...

84

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

85

Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator  

Energy Technology Data Exchange (ETDEWEB)

The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10{sup 14} cm{sup -2}) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.

2004-12-15

86

Implant damage and redistribution of indium in indium-implanted thin silicon-on-insulator  

International Nuclear Information System (INIS)

The indium implant damage and diffusion behavior in thin silicon-on-insulator (SOI) with a 200 nm top silicon layer were studied for different implantation energies and doses. Rutherford backscattering spectrometry in the channeling mode (RBS/C) was used to characterize the implant damage before and after annealing. Secondary ion mass spectrometry (SIMS) was used to study the indium transient enhanced diffusion (TED) behavior in the top Si layer of the SOI structure. An anomalous redistribution of indium after relatively high energy (200 keV) and dose (1 x 10"1"4 cm"-"2) implantation was observed in both bulk Si and SOI substrates. However, there exist differences in these two substrates that are attributable to the more predominant out-diffusion of indium as well as the influence of the buried oxide layer in the SOI structure.

2004-12-15

87

Diffusion modeling of ion implanted boron in Si during RTA: Correlation of extended defect formation and annealing with the enhanced diffusion of boron  

International Nuclear Information System (INIS)

Accurate modeling of the enhanced diffusion of boron during rapid thermal annealing has been accomplished by incorporating the effects of extended defect formation and annealing on enhanced diffusion into a multizone, semiempirical model. The multizone model divides the implant profile into three zones defining regions of different defects and diffusion enhancements. The model also contains the initial enhanced diffusion and the transient diffusion effects associated with the dissolution of defect clusters and the annealing of extended defects, respectively. The saturation time for transient-enhanced diffusion contains an exponential function of implant dose in order to model the increase in point defect generated with higher implant dose. As a result, the model accurately simulates the boron diffusion profile over a wide range of implant doses and also shows the immobile boron peak of precipitated ...

88

A study on yellow luminescence in O and C ion implanted GaN  

International Nuclear Information System (INIS)

The effects of O and C ion implantation with different implantation doses on the yellow luminescence (YL) from unintentional doped n-type GaN have been studied by the photoluminescence (PL) spectra. O and C ions were implanted in the GaN samples with different doses from 1.0 x l013 to 1.0 x l017cm-2. Post-annealing was done in a quartz open-tube furnace under flowing N2 gas for 30 min at 950 degree C. By comparing with N ion implanted samples, it is assumed that different deep-level centers involving in the YL were produced in GaN after O and C ion implantation. In addition, with a dose of 1017 cm-2, the concentration of deep C centers involving in the YL was enhanced markedly. (authors)

2008-08-01

89

Urethrorectal fistula in a horse.  

UK PubMed Central (United Kingdom)

Anomalies of the urethra are uncommon. Urethrorectal fistula in horses has only been reported in foals and only in conjunction with other congenital anomalies. This report describes the diagnosis, surgical...Full Text Available

1999-02-01

90

Traumatic retinal detachment.  

UK PubMed Central (United Kingdom)

Seventy-seven patients developed retinal breaks following an episode of ocular contusion, and 65 (84.4%) of these developed rhegmatogenous retinal detachment. Surgical treatment successfully restored...Full Text Available

1991-01-01

91

Surgical navigation using audio feedback.  

Science.gov (United States)

Current medical visualization technology intended for positional guidance in surgical applications may only ever have limited utility in the operating room due to the preexisting visual requirements of surgical practice. Additionally, visual systems impose limits as a result of their high latency, poor image resolution, problems with stereopsis and physical strain upon the user. Audio technology is relatively unexamined in the broad range of available methodologies for medical devices. The potential to translate surgical instrument position into audio feedback presents a novel solution to the human factors and engineering problems faced by visual display technology because audio technology employs a rich and as yet unburdened sensory modality. We describe an experimental system we have developed for investigating this new interface design approach using commercially available hardware. PMID:10173065

1997-01-01

92

Surgical dislocation of the hip and the management of femoroacetabular impingement: results of the Christchurch experience  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background:- Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. Methods:- We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. Results:- There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index ...

2011-01-01

93

Recent advances in the management of carcinoma of the rectum  

UK PubMed Central (United Kingdom)

In the last two decades rectal cancer has changed from a surgically managed disease into a multidisciplinary treatment model resulting in considerable improvements in the survival and outcome. This...Full Text Available

94

Quality of Surgical Instruments  

UK PubMed Central (United Kingdom)

INTRODUCTIONMany surgeons will have encountered the scissors that would not cut, and the artery clip that comes off in a deep difficult location, but it would be reasonable to assume...Full Text Available

2006-07-01

95

Peritonectomy procedures.  

UK PubMed Central (United Kingdom)

OBJECTIVE: New surgical procedures designed to assist in the treatment of peritoneal surface malignancy were sought. BACKGROUND: Decisions regarding the treatment of cancer depend on the anatomic location...Full Text Available

1995-01-01

96

Percutaneous tracheostomy  

UK PubMed Central (United Kingdom)

Background:Percutaneous tracheostomy (PT) has gained an increasing acceptance as an alternative to the conventional surgical tracheostomy (ST). In experienced hands, and with...Full Text Available

1999-01-01

97

Minimally Invasive Parathyroidectomy Using Surgical Sonography  

UK PubMed Central (United Kingdom)

Minimally invasive parathyroidectomy is the procedure of choice for primary hyperparathyroidism due to parathyroid adenoma. Localization of the offending adenoma in minimally invasive parathyroidectomy...Full Text Available

98

Local excision as a treatment for tumors of ampulla of Vater  

UK PubMed Central (United Kingdom)

BackgroundAlthough local excision (ampullectomy) was first described by Halsted in 1899, its adequacy as an alternative surgical treatment for the ampullary tumors is still a matter...Full Text Available

99

Investigation of drug delivery by iontophoresis in a surgical wound utilizing microdialysis  

UK PubMed Central (United Kingdom)

Purpose:This study investigated the penetration of lidocaine around and through a sutured incision following the application of iontophoretic and passive patches...Full Text Available

2008-08-01

100

If I Had - Morbid Obesity  

Medline Plus

... for a stapling or division of tissue the creation of a small gastric pouch which then assists ... follow up. Laparoscopic gastric bypass entails the surgical creation of a small gastric pouch, typically about an ...

101

Endometriosis  

Medline Plus

... endometriosis can be seen is by doing a laparoscopy. A laparoscopy is a surgical procedure used to look at ... of the abdomen using special scopes. During a laparoscopy, the doctor is able to take small samples ...

102

A cost-utility analysis of open and endoscopic carpal tunnel release  

UK PubMed Central (United Kingdom)

BACKGROUNDOpen carpal tunnel release (OCTR) is the standard procedure for the surgical treatment of carpal tunnel syndrome. With the advent of minimally invasive surgery, endoscopic...Full Text Available

2006-01-01

103

Whole-mount specimens in the analysis of en bloc samples obtained from revisions of resurfacing hip implants  

UK PubMed Central (United Kingdom)

BackgroundModern metal-on-metal hip resurfacing implants are being increasingly used for young and active patients, although the long-term outcome and failure mechanisms of these...Full Text Available

2010-06-01

104

Transient enhanced diffusion of Sb and B due to MeV silicon implants  

Energy Technology Data Exchange (ETDEWEB)

We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si{sup +} ion implants at very high doses ({approx}10{sup 16}cm{sup {minus}2}). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation ({approx}700 at 740{degree}C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of {l_brace}311{r_brace} defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV ...

1997-06-01

105

Transient enhanced diffusion of Sb and B due to MeV silicon implants  

International Nuclear Information System (INIS)

We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si"+ ion implants at very high doses (#approx#10"1"6cm"-"2). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation (#approx#700 at 740 degree C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of #left brace#311#right brace# defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant ...

106

Time-resolved reflectance studies of silicon during laser thermal processing of amorphous silicon gates on ultrathin gate oxides  

International Nuclear Information System (INIS)

In this paper, we report the systematic investigation on the melt characteristics of silicon during laser thermal processing (LTP) of amorphous silicon (a-Si) gates on ultrathin gate oxides. LTP is used to reduce the gate depletion effect in advanced semiconductor devices. The influence of implantation-induced damage and chemical inhomogeneities on the melt behavior of ion-implanted a-Si is studied using in situ time-resolved reflectance (TRR) measurements and ex situ secondary ion mass spectrometry. The results from TRR measurements indicate the presence of a buried melt for a-Si implanted with B"+ at a subamorphizing dose. In contrast, such a melt behavior is not observed during LTP of undoped a-Si and a-Si implanted with As"+ at an amorphizing dose. We attribute the marked difference in the melt characteristics to the competitive effects between compositional inhomogeneities and the extent of ...

2004-06-01

107

Sensitivity of psychophysical measures to signal processor modifications in cochlear implant users  

UK PubMed Central (United Kingdom)

Experienced users of the Clarion cochlear implant were tested acutely with the HiResolution (HiRes) and HiRes Fidelity120 (F120) processing strategies. Three psychophysically-based tests were...Full Text Available

2010-04-01

108

Production and stability of implanted Pd-Si hydride  

Energy Technology Data Exchange (ETDEWEB)

Combining in situ Rutherford backscattering and electrical transport measurements on low-temperature hydrogen-implanted amorphous Pd/sub 80/Si/sub 20/ films, we have studied the correlation between the hydrogen content and the resistivity.

1983-05-01

109

Paying for treatments? Influences on negotiating clinical need and decision-making for dental implant treatment  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study is to examine how clinicians and patients negotiate clinical need and treatment decisions within a context of finite resources. Dental implant treatment...Full Text Available

110

Patient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve  

UK PubMed Central (United Kingdom)

Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation...Full Text Available

2010-06-28

111

Noise Susceptibility of Cochlear Implant Users: The Role of Spectral Resolution and Smearing  

UK PubMed Central (United Kingdom)

The latest-generation cochlear implant devices provide many deaf patients with good speech recognition in quiet listening conditions. However, speech recognition deteriorates rapidly as the level of...Full Text Available

2005-03-01

112

Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV ...

1999-03-01

113

Mechanism for the reduction of interstitial supersaturations in MeV-implanted silicon  

International Nuclear Information System (INIS)

We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si ...

1999-03-01

114

Effects of Semantic Context and Feedback on Perceptual Learning of Speech Processed through an Acoustic Simulation of a Cochlear Implant  

UK PubMed Central (United Kingdom)

The effect of feedback and materials on perceptual learning was examined in normal hearing listeners exposed to cochlear implant simulations. Generalization was most robust when feedback paired...Full Text Available

2010-02-01

115

Early Wound Healing Following One-Stage Dental Implant Placement With and Without Antibiotic Prophylaxis: A Pilot Study  

UK PubMed Central (United Kingdom)

BackgroundOne-stage implant placement has clinically acceptable treatment outcomes. Among other advantages, it may allow investigation of early wound healing. The...Full Text Available

2008-10-01

116

Discrimination of Schroeder-Phase Harmonic Complexes by Normal-Hearing and Cochlear-Implant Listeners  

UK PubMed Central (United Kingdom)

The temporal fine structure (TFS) of sound contributes significantly to the perception of music and speech in noise. The evaluation of new strategies to improve TFS delivery in cochlear implants (CIs)...Full Text Available

2008-03-01

117

Observation of a surface peak in low energy implant depth profiles in silicon  

Energy Technology Data Exchange (ETDEWEB)

In situ Auger sputter depth profiles of saturation implants of 3 keV N/sub 2//sup +/ in silicon at room temperature exhibit a sharp peak in the nitrogen concentration in the outermost layers, followed by a monotonic decrease. No broad plateau was observed. The energy of the Auger line corresponding to the Si(2p) core electron excitation, monitored throughout the profiling, exhibits a chemical shift of up to 7 eV at the surface peak concentration. Inert gas ion post-bombardment of unsaturated implants significantly modifies the profile, and supports the suggestion that the surface peak arises through radiation enhanced diffusion of implanted atoms.

1984-03-01

118

NEUROPLASTICITY and INNOVATION  

Science.gov (United States)

OF VOCALIZED SPEECH THROUGH. ANALYSIS OF NEURAL SIGNALS. " SYNTHETIC TELEPATHY- WIRELESS. TRANSMISSION OF DECODED. THOUGHTS. " IMPLANTABLE MEMORY-ELIMINATES ...

119

Interstitial injection in silicon after high-dose, low-energy arsenic implantation and annealing  

International Nuclear Information System (INIS)

In this work, we investigate the interstitial injection into the silicon lattice due to high-dose, low-energy arsenic implantation. The approach consists in monitoring the diffusion of the arsenic profile as well as of the boron profile in buried #delta#-doped layers, when amounts of the as-implanted arsenic profile are removed by low-temperature wet silicon etching. The experimental results indicate that the contribution of the implantation damage to the transient enhanced diffusion of boron, and thus the interstitial injection, is not the main one. On the contrary, interstitial generation due to arsenic clustering seems to be more important for the present conditions.

2005-11-14

120

Guidance for Industry  

Science.gov (United States)

... central venous catheters (tunneled [eg, Hickman], subcutaneously implanted [eg, Porta-cath], and nontunneled), peripherally inserted central venous catheters ...

121

Alignment accuracy of focused ion beam implantation  

Energy Technology Data Exchange (ETDEWEB)

The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.

1987-06-01

122

Solutions to defect-related problems in implanted silicon by controlled injection of vacancies by high-energy ion irradiation  

Energy Technology Data Exchange (ETDEWEB)

Amorphization and a dual implant technique have been used to manipulate residual defects that persist following implantation and post-implant thermal treatments. Residual defects can often be attributed to ion-induced defect excesses. A defect is considered to be excess when it occurs in a localized region at a concentration greater than its complement. Sources of excess defects include spatially separated Frenkel pairs, excess interstitials resulting from the implanted atoms, and sputtering. Preamorphizing prior to dopant implantation has been proposed to eliminate dopant broadening due to ion channeling as well as dopant diffusion during subsequent annealing. However, transient-enhanced diffusion (TED) of implanted boron has been observed in pre-amorphized Si. The defects driving this enhanced boron diffusion are thought to be the extended interstitial-type ...

1999-06-01

123

Solutions to defect-related problems in implanted silicon by controlled injection of vacancies by high-energy ion irradiation  

International Nuclear Information System (INIS)

Amorphization and a dual implant technique have been used to manipulate residual defects that persist following implantation and post-implant thermal treatments. Residual defects can often be attributed to ion-induced defect excesses. A defect is considered to be excess when it occurs in a localized region at a concentration greater than its complement. Sources of excess defects include spatially separated Frenkel pairs, excess interstitials resulting from the implanted atoms, and sputtering. Preamorphizing prior to dopant implantation has been proposed to eliminate dopant broadening due to ion channeling as well as dopant diffusion during subsequent annealing. However, transient-enhanced diffusion (TED) of implanted boron has been observed in pre-amorphized Si. The defects driving this enhanced boron diffusion are thought to be the extended interstitial-type ...

1999-06-01

124

On the theory of transient enhanced diffusion in boron-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion in boron-implanted silicon is interpreted as being due to the fact that during rapid thermal annealing a relaxation process takes place, associated with quasi-chemical reactions including defects. A simple analytical model makes it possible to describe the annealing mechanism on a microscopic scale in terms of reaction-diffusion processes. The measured dependences of the boron diffusion coefficient of the enhanced diffusion on time, temperature and implantation energy are satisfactorily explained. (author).

1991-01-01

125

On the theory of transient enhanced diffusion in boron-implanted silicon  

International Nuclear Information System (INIS)

Transient enhanced diffusion in boron-implanted silicon is interpreted as being due to the fact that during rapid thermal annealing a relaxation process takes place, associated with quasi-chemical reactions including defects. A simple analytical model makes it possible to describe the annealing mechanism on a microscopic scale in terms of reaction-diffusion processes. The measured dependences of the boron diffusion coefficient of the enhanced diffusion on time, temperature and implantation energy are satisfactorily explained. (author).

126

Improvement of the parameters of shallow p"+-n-junctions in silicon by additional carbon implantation and step-by-step thermal treatments  

International Nuclear Information System (INIS)

In this article carbon co-implantation and step-by-step thermal treatments of shallow p"+-n-junctions formation were used with the purpose of extended defect suppression and reduction of boron transient enhanced diffusion. A substantial improvement of the structural and electrical parameters of shallow p"+-n-junctions has been achieved by using the additional carbon implantation and step-by-step thermal treatments. (authors)

127

Implantation-plasma treatment of martensitic steel and titanium alloy  

Energy Technology Data Exchange (ETDEWEB)

One of the effective methods of deep modification of the surface of steels and alloys is the combination of ion implantation and plasma nitriding. In this work, the long-range effect is demonstrated in the case of combination of the effect of high- and low-energy ions of nitrogen on a martensitic steel for each ion implantation is usually not effective, and a titanium alloy used widely in industry.

2001-07-01

128

Preoperative factors predictive of postoperative decimal visual acuity ? 1.0 following surgical treatment for idiopathic epiretinal membrane  

UK PubMed Central (United Kingdom)

Purpose:To report the preoperative best-corrected visual acuity (BCVA) and foveal thickness (FT) values that lead to a postoperative decimal BCVA of ≥1.0 after surgical removal...Full Text Available

2011-01-01

129

The effect of excimer laser pretreatment on diffusion and activation of boron implanted in silicon  

International Nuclear Information System (INIS)

We have investigated the effect of excimer laser annealing (ELA) on transient enhanced diffusion (TED) and activation of boron implanted in Si during subsequent rapid thermal annealing (RTA). It is observed that ELA with partial melting of the implanted region causes reduction of TED in the region that remains solid during ELA, where the diffusion length of boron is reduced by a factor of #approx#4 as compared to the as-implanted sample. This is attributed to several mechanisms such as liquid-state annealing of a fraction of the implantation induced defects, introduction of excess vacancies during ELA, and solid-state annealing of the defects beyond the maximum melting depth by the heat wave propagating into the Si wafer. The ELA pretreatment provides a substantially improved electrical activation of boron during subsequent RTA.

2005-11-07

130

Status and progress in ion implantation technology for semiconductor device manufacturing  

International Nuclear Information System (INIS)

Rapid growth in implant applications in the fabrication of semiconductors has encouraged a dramatic increase in the range of energies, beam currents and ion species used. The challenges of a wider energy range, higher beam currents, continued reduction in contamination, improved angle integrity and larger substrates have motivated the development of many innovations. Advanced processes in submicron device production uses up to twenty implantation steps. Thus the outstanding growth of this industry has led to the evolution of a thriving business of hundreds of implantation equipment systems each year with very specific requirements. The present paper reviews the principal process requirements which resulted in the evolution of the equipment technology, and describes the recent trends in the ion implanter technology all three principal categories: high current, medium current and high energy. (author)

1998-12-08

131

RHEED, AES and XPS studies of the passive films formed on ion implanted stainless steel  

International Nuclear Information System (INIS)

P-implantation (10"1"7 ions cm"-"2, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H_2SO_4+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H_2SO_4. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.

2005-05-26

132

RHEED, AES and XPS studies of the passive films formed on ion implanted stainless steel  

Energy Technology Data Exchange (ETDEWEB)

P-implantation (10/sup 17/ ions cm/sup -2/, 40 KeV) into 304 stainless steel (ss) has been carried out, and an amorphous surface alloy was formed. Polarization studies in deaerated 1N H/sub 2/SO/sub 4/+ 2% NaCl showed that P-implantation improved both the general and localized corrosion resistance of 304 ss. A comparative study has been carried out between the implanted and unimplanted steel to determine what influence P-implantation has upon the properties of the passive film formed 1N H/sub 2/SO/sub 4/. The influence of Cl ions on pre-formed passive films was also studied. RHEED, XPS and AES were used to evaluate the nature of the passive films formed in these studies.

1981-12-01

133

Photosensitivity and imaging characteristics of ion-implanted PLZT ceramics  

International Nuclear Information System (INIS)

We reported in previous papers that both the near-uv and the visible photosensitivities of ferroelectric-phase PLZT (lead lanthanum zirconate titanate) ceramics are increased by as much as four orders of magnitude by ion implantation or a combination of thermal diffusion of Al and ion implantation. New results are presented here on high-energy (1 MeV) implants of Al and Ni and coimplants of Al + Ne and Ni + Ne, and these results are compared with earlier 500 keV implants of Al and Cr and coimplants of Al + Ne and Cr + Ne as surface modification techniques for increasing the visible photosensitivity of PLZT. The important role of grain size in determining optimum contrast and resolution of stored optical information is described in terms of new experimental results.

1985-08-12

134

Ion implantation into concave polymer surface  

Energy Technology Data Exchange (ETDEWEB)

A new technique for ion implantation into concave surface of insulating materials is proposed and experimentally studied. The principle is roughly described by referring to modifying inner surface of a PET (polyethylene terephthalate) bottle. An electrode that is supplied with positive high-voltage pulses is inserted into the bottle. Both plasma formation and ion implantation are simultaneously realized by the same high-voltage pulses. Ion sheath with a certain thickness that depends on plasma parameters is formed just on the inner surface of the bottle. Since the plasma potential is very close to that of the electrode, ions from the plasma are accelerated in the sheath and implanted perpendicularly into the bottle's inner surface. Laser Raman spectroscopy shows that the inner surface of an ion-implanted PET bottle is modified into DLC (diamond-like carbon). Gas permeation measurement shows ...

2006-01-15

135

Influence of substitutional carbon incorporation on implanted-indium-related defects and transient enhanced diffusion  

International Nuclear Information System (INIS)

It has been demonstrated that, by incorporating a thin #approx#20 nm Si_1_-_yC_y (with y as low as 0.1%) layer at the deep indium implant end-of-range (EOR) region, the EOR defects and enhanced diffusion behavior associated with indium implant can be eliminated. The Si_1_-_yC_y layer was grown epitaxially followed by a silicon epitaxy cap of 60 nm. Indium implantations were performed at 1x10"1"4 cm"-"2 at 115 keV followed by spike annealing at 1050 deg. C. The experimentally observed EOR defect and enhanced diffusion elimination are explained based on the undersaturation of implantation-induced silicon interstitials with the presence of substitutional carbon at the Si_1_-_yC_y layer.

2003-11-17

136

In-vitro evaluation of corrosion resistance of nitrogen ion implanted titanium simulated body fluid  

International Nuclear Information System (INIS)

Titanium and its alloy Ti6Al4V enjoy widespread use in various biomedical applications because of favourable local tissue response, higher corrosion resistance and fatigue strength than the stainless steels and cobalt-chromium alloy previously used. The study reported in this paper aims to optimize the conditions of nitrogen ion implantation on commercially pure titanium and to correlate the implantation parameters to the corrosion resistance. X-ray photoelectron spectroscopy was used to analyse surface concentration and the implantation processes. An improvement in the electrochemical behaviour of the passive film was shown to occur with nitrogen ion implantation on titanium, in simulated body fluids. (UK).

137

Implantation processing of Si: A unified approach to understanding ion-induced defects and their impact  

Energy Technology Data Exchange (ETDEWEB)

A model is presented to account for the effects of ion-induced defects during implantation processing of Si. It will be shown that processing is quite generally affected by the presence of defect excesses rather than the total number of defects. a defect is considered excess if it represents a surplus locally of one defect type over its compliment. Processing spanning a wide range of implantation conditions will be presented to demonstrate that the majority of the total defects played little or no role in the process. This is a direct result of the ease with which the spatially correlated Frenkel pairs recombine either dynamically or during a post-implantation annealing. Based upon this model, a method will be demonstrated for manipulating or engineering the excess defects to modify their effects. In particular high-energy, self-ions are shown to inject vacancies into a boron implanted region resulting ...

1997-05-01

138

Effect of recoil implantation of oxygen on boron enhanced diffusion in silicon  

International Nuclear Information System (INIS)

In device fabrication, dopants are frequently implanted into silicon through silicon dioxide masks. A consequence of this technique is the co-implantation of recoiled oxygen into the substrate. This study investigates the effect of recoiled oxygen on the widely observed transient enhanced boron diffusion. Comparison of the spreading resistance profiles of annealed through-oxide and directly implanted samples reveals that transient enhanced diffusion of boron can be suppressed by the former process. Continued annealing of the through-oxide implanted silicon recovers the enhanced diffusion of boron. This behavior is believed to be due to precipitation of recoiled oxygen. The mechanisms leading to the above observations are discussed and transmission electron microscopy support presented. 11 refs., 5 figs.

1989-04-25

139

Bacterial adhesion reduction on a biocompatible Si^+ ion implanted austenitic stainless steel  

British Library Electronic Table of Contents (United Kingdom)

The colonization of an implant surface by bacteria is an extremely important medical problem, which often leads to the failure of medical devices. Modern surface modification techniques, such as ion implantation, can confer to the surfaces very different properties from those of the bulk underlying material. In this work, austenitic stainless steel 316 LVM has been superficially modified by Si^+ ion implantation. The effect of surface modification on the biocompatibility and bacterial adhesion to 316 LVM stainless steel has been investigated. To this aim, human mesenchymal stem cells (hMSCs), as precursor of osteoblastic cells, and bacterial strains relevant in infections related to orthopedic implants, i.e., Staphylococcus aureus and Staphylococcus epidermidis, have been assayed. For the ...

2011-01-01

140

Annealing of silicon implanted with arsine and hydrogen ions  

Energy Technology Data Exchange (ETDEWEB)

Arsenic and hydrogen ions produced from a mixture of arsine and hydrogen gas were implanted with a dose of 3 x 10{sup 15} As{sup +} ions/cm{sup 2} into silicon using an ion-shower implanter. The dominant ionic species implanted into the silicon were As{sub 2}H{sup +}, AsH{sup +}, H{sub 5}{sup +}, and H{sub 3}{sup +} ions. Arsenic atoms diffused into the silicon with large diffusion coefficients during annealing at 700 and 800 C. However, when the implanted silicon was annealed at 900 C, the arsenic atoms diffused into a deeper region in the silicon with a very small diffusion coefficient that was independent of concentration. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

2003-01-01

141

Heated lipiodol as an embolization agent for transhepatic arterial embolization in VX2 rabbit liver cancer model  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the therapeutic effect of heated (60 deg. C) lipiodol via hepatic artery administration in a rabbit model of VX2 liver cancer. Materials and methods: Thirty male New Zealand white rabbits were randomly divided into three groups with 10 rabbits assigned to each group. VX2 carcinoma cells were surgically implanted into the left hepatic lobe. The tumors were allowed to grow for 2 weeks, and studies were performed until the diameter of the tumors detected by ultrasonograph reached 2-3 cm. Under anesthesia, trans-catheter hepatic arterial embolization was performed and doxorubicin-lipiodol (37 deg. C) (1 mL), lipiodol (60 deg. C) (1 mL) or control (physiological saline (37 deg. C) (1 mL)) solution was injected into the hepatic arteries of animals in the three groups. One week later, the volume of the tumor was measured by ultrasonograph again. The serum of all rabbits was collected before injection and at 4 and 7 days after ...

2010-02-15

142

XPS study of the passive films formed on nitrogen-implanted austenitic stainless steels  

Energy Technology Data Exchange (ETDEWEB)

Austenitic stainless steels (304-type) have been implanted with nitrogen ions in order to investigate the effects of implanted nitrogen on their electrochemical behaviour and on the nature of the passive film formed on the steels in acid (0.5M H{sub 2}SO{sub 4}). Alloys with two nitrogen doses have been prepared (2.5x10{sup 16} and 2x10{sup 17} N atoms/cm{sup 2}). The implanted alloys have been characterized by {sup 15}N-NRA (nuclear reaction analysis) and XPS (X-ray photoelectron spectroscopy). Alloy surfaces with well-defined N concentrations were prepared, prior to the electrochemical measurements, by argon-ion sputtering of the implanted material for a fixed time in order to reach a well-defined point on the nitrogen depth profile. The samples were then transferred without exposure to air to an electrochemical cell mounted in an inert gas glove box. The implanted nitrogen ...

1992-05-01

143

XPS study of the passive films formed on nitrogen-implanted austenitic stainless steels  

International Nuclear Information System (INIS)

Austenitic stainless steels (304-type) have been implanted with nitrogen ions in order to investigate the effects of implanted nitrogen on their electrochemical behaviour and on the nature of the passive film formed on the steels in acid (0.5M H_2SO_4). Alloys with two nitrogen doses have been prepared (2.5x10"1"6 and 2x10"1"7 N atoms/cm"2). The implanted alloys have been characterized by "1"5N-NRA (nuclear reaction analysis) and XPS (X-ray photoelectron spectroscopy). Alloy surfaces with well-defined N concentrations were prepared, prior to the electrochemical measurements, by argon-ion sputtering of the implanted material for a fixed time in order to reach a well-defined point on the nitrogen depth profile. The samples were then transferred without exposure to air to an electrochemical cell mounted in an inert gas glove box. The implanted nitrogen modifies the electrochemical ...

1992-01-01

144

Modification of the passivity of iron based alloys through ion implantation  

International Nuclear Information System (INIS)

As an unconventional surface alloying process, ion implantation has been utilized to improve the active-passive behavior and the pitting resistance of martensitic M50 engineering alloy. In a field simulation study, Cr-implantation only at 150 kev to a fluence of 2 x 10"1"7 ions/cm"2 prevented pitting. The best pitting resistance of the steel was obtained with multiple implantations of Cr and Mo. The intermixing effect of high fluence P-implantation into 304 stainless produced an amorphous surface alloy. The removal of the grain boundaries and the uniformity of the resulting structure had a great influence on corrosion properties. REED analysis indicated that the anodic passive films formed on P-implanted 304 stainless steel at 250 mV (SCE) in 0.5M H_2SO_4 was amorphous. Phosphorus and boron were implanted into 316 stainless steel to study the passivity of 316 ...

1764-01-01

145

Modelisation of boron diffusion from ultra-low-energy implantation in crystalline silicon  

Energy Technology Data Exchange (ETDEWEB)

We have investigated and modeled the boron diffusion in silicon following ultra-low-energy implantation (500 eV). It is well known that reducing implant energies is an effective way to eliminate transient enhanced diffusion due to the excess of interstitials from the implant. However, for sub-keV B implants diffusion remains enhanced. This enhancement is linked to the presence of a silicon boride layer located at the silicon surface which creates interstitials. This phenomenon is named 'boron enhanced diffusion' (BED). The BED effect is of obvious interest since it counteracts the advantage obtained by reducing the ion implantation energy. For these reasons, we have investigated the diffusion of low-energy boron implanted in crystalline silicon and tested a complete simulation program, which takes into account the effect of boron precipitation ...

2003-12-31

146

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO_2 films  

International Nuclear Information System (INIS)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to ...

147

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO[sub 2] films  

Energy Technology Data Exchange (ETDEWEB)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to ...

1993-07-16

148

Enhanced diffusion of dopants in vacancy supersaturation produced by MeV implantation  

Energy Technology Data Exchange (ETDEWEB)

The diffusion of Sb and B markers has been studied in vacancy supersaturations produced by MeV Si implantation in float zone (FZ) silicon and bonded etch-back silicon-on-insulator (BESOI) substrates. MeV Si implantation produces a vacancy supersaturated near-surface region and an interstitial-rich region at the projected ion range. Transient enhanced diffusion (TED) of Sb in the near surface layer was observed as a result of a 2 MeV Si{sup +}, 1 {times} 10{sup 16}/cm{sup 2}, implant. A 4{times} larger TED of Sb was observed in BESOI than in FZ silicon, demonstrating that the vacancy supersaturation persists longer in BESOI than in FZ. B markers in samples with MeV Si implant showed a factor of 10{times} smaller diffusion relative to markers without the MeV Si{sup +} implant. This data demonstrates that a 2 MeV Si{sup +} implant injects vacancies into the near ...

1997-04-01

149

Doping of silicon carbide by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

A brief survey is given of some recent results on doping of 4H- and 6H-SiC by ion implantation. The doses and energies used are between 10{sup 9} and 10{sup 15} cm{sup -2} and 100 keV and 5 MeV, respectively, and B and Al ions (p-type dopants) are predominantly studied. After low dose implantation ({<=}10{sup 10} cm{sup -2}) a strong compensation is observed in n-type samples and this holds irrespective of implantation temperature up to 600 C. However, at higher doses (10{sup 14}-10{sup 15} Al/cm{sup 2}) the rate of defect recombination (annihilation) increases substantially during hot implants ({>=}200 C), and in these samples one type of structural defect dominates after post-implant annealing at 1700-2000 C. The defect is identified as a dislocation loop composed of clustered interstitial atoms inserted on the basal plane in the hexagonal crystal structure. Finally, ...

2001-07-01

150

Tucannon River Spring Chinook Captive Broodstock Program Final Environmental Assessment and Finding of No Significant Impact  

Energy Technology Data Exchange (ETDEWEB)

Bonneville Power Administration (BPA) is proposing to fund the Tucannon River Spring Chinook Captive Broodstock Program, a small-scale production initiative designed to increase numbers of a weak but potentially recoverable population of spring chinook salmon in the Tucannon River in the State of Washington. BPA has prepared an Environmental Assessment (EA) (DOE/EA-l326) evaluating the proposed project. Based on the analysis in the EA, BPA has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an Environmental Impact Statement (EIS) is not required, and BPA is issuing this Finding of No Significant Impact (FONSI).

2000-05-24

151

Development and validation of control materials for the measurement of vitamin D3 in selected US foods  

British Library Electronic Table of Contents (United Kingdom)

As part of the United States Department of Agricultures (USDA) National Food and Nutrient Analysis Program (NFNAP), food composition data for vitamin D in the USDA National Nutrient Database for Standard Reference are being updated and expanded, focusing on high priority foods and validated analytical methodology. A lack of certified reference materials and analytical methods validated for these key foods required the development of five matrix-specific control composite materials (CC) (canned salmon and vitamin D3 fortified cereal, orange juice, milk, and cheese). Each of six experienced laboratories (research and commercial) analyzed vitamin D3 in five subsamples of each CC in five separate analytical batches, with one subsample of each material in each run. Research laboratories perform...

2008-01-01

152

Assess Current and Potential Salmonid Production in Rattlesnake Creek Associated with Restoration Efforts; Yakama Indian Nation, Annual Report 2002-2003.  

Energy Technology Data Exchange (ETDEWEB)

This document represents the FY2002 BPA contract Statement of Work for the Yakama Nation (YN) portion of the project entitled 'Assessment of current and potential salmonid production in Rattlesnake Creek associated with restoration efforts'. The purpose of the project is to complete detailed surveys of water quality, fish populations, habitat conditions and riparian health in the Rattlesnake Creek sub-basin of the White Salmon River in south central Washington. Results of the surveys will be used to establish Rattlesnake Creek sub-basin baseline environmental factors prior to anticipated removal of Condit Dam in 2006 and enable cost-effective formulation of future watershed restoration strategies.

2003-05-01

153

Preventing surgical fires: who needs to be educated?  

Science.gov (United States)

BACKGROUND AND CASE STUDY: Surgical fires are rare but preventable. During facial surgery for a 68-year-old man, a fire broke out, resulting in first- and second-degree burns after a nasal cannula ignited in an oxygen-rich environment because of improper draping and tenting. DISCUSSION: Operating room (OR) fires can be prevented if any component of the "fire triangle"-fuels, ignition sources, and oxidizers-is reduced or eliminated. The use of supplemental oxygen in the OR via nasal cannulae, nebulizers, and oxygen cylinders must always considered a potential source of fire. Deficits in knowledge among the surgical team with respect to the prevention and management of surgical fires were apparent. A plan was put into place to improve fire safety education, entailing an educational program that is included in intern and resident orientation. Surgical fire safety training was also put into place for ...

2005-09-01

154

Orthognathic treatment with maxillary and mandibular anterior segmental osteotomy  

British Library Electronic Table of Contents (United Kingdom)

This case report presents a case that underwent orthognathic treatment with anterior segmental osteotomies on both jaws. The patient was a 26-year-old female with maxillary protrusion, lip incompetence with an everted vermilion border. The overbite was +1.0mm, overjet +1.0mm. The pre-surgical orthodontic treatment included the extraction of the four first premolars and a multi-bracket treatment was started. After 12 months of pre-surgical orthodontic treatment, both the anterior maxillary and the anterior mandibular segments were retracted surgically by 5.5mm. The total treatment period was 18 months. An anterior segmental osteotomy can induce the remarkable structural changes for bimaxillary lip protrusion patients.

2009-01-01

155

Fifteen-year follow-up of a patient with beta thalassaemia and extramedullary haematopoietic tissue compressing the spinal cord  

Energy Technology Data Exchange (ETDEWEB)

A long-term follow-up of a patient with beta thalassaemia with intra- and extraspinal extramedullary haematopoietic tissue compressing the spinal cord is presented. Extramedullary haematopoietic nodules are a rare cause of spinal cord compression and should be included in the differential diagnosis, especially in patients from Mediterranean countries. Treatment with radiation therapy solely failed, giving rise to the need of surgical intervention. Surgical decompression of the spine and the removal of the culprit lesion compressing the spine were performed. Postinterventional radiation therapy was applied to the spine. A relapse had to be treated again by surgical means combined with postinterventional radiation therapy. A complete relief of the symptoms and control of the lesion could be obtained.

2005-04-01

156

Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5{times}10{sup 12} to 1{times}10{sup 14}/cm{sup 2} evolves into a distribution of {l_brace}311{r_brace} interstitial agglomerates during the initial annealing stages at 670{endash}815{degree}C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of ...

1997-05-01

157

Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5x10"1"2 to 1x10"1"4/cm"2 evolves into a distribution of #left brace#311#right brace# interstitial agglomerates during the initial annealing stages at 670 endash 815 degree C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from ...

158

Work plan addendum for the remedial investigation and feasibility study of the Salmon Site  

Energy Technology Data Exchange (ETDEWEB)

This document is intended as an addendum to the Remedial Investigation and Feasibility Study (RI/FS) Work Plan for the Salmon Site (SS) (formerly the Tatum Dome Test Site) Lamar County, Mississippi. The original work plan - Remedial Investigation and Feasibility Study of the Tatum Dome Test Site, Lamar County, Mississippi (herein after called the Work Plan) was approved by the state of Mississippi in 1992 and was intended as the operative document for investigative activities at the Tatum Dome Test Site. Subsequent to the approval of the document a series of activities were undertaken under the auspices of the work plan. This document is organized in the same manner as the original work plan: (1) Introduction; (2) Site Background and History; (3) Initial Evaluation; (4) Data Quality Objectives; (5) RI/FS Tasks; (6) Project Schedule; (7) Project Management; and (8) Reference. This addendum will identify changes to the original work plan that are necessary because of ...

1995-11-01

159

Survival Estimates for the Passage of Juvenile Salmonids through Snake River Dams and Reservoirs, 1996 Annual Report  

Energy Technology Data Exchange (ETDEWEB)

In 1996, the National Marine Fisheries Service and the University of Washington completed the fourth year of a multi-year study to estimate survival of juvenile salmonids (Oncorhynchus spp.) passing through dams and reservoirs on the Snake River. Actively migrating smolts were collected near the head of Lower Granite Reservoir and at Lower Granite Dam, tagged with passive integrated transponder (PIT) tags, and released to continue their downstream migration. Individual smolts were subsequently detected at PIT-tag detection facilities at Lower Granite, Little Goose, Lower Monumental, McNary, John Day and Bonneville Dams. Survival estimates were calculated using the Single-Release (SR) and Paired-Release (PR) Models. Timing of releases of tagged hatchery steelhead (O. mykiss) from the head of Lower Granite Reservoir and yearling chinook salmon (O. tshawytscha) from Lower Granite Dam in 1996 spanned the major portion of their juvenile migrations. Specific research ...

1998-02-01

160

Understanding and controlling transient enhanced dopant diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during initial annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, the authors have used B doping marker layers in Si to probe the injection of interstitials from near-surface, non-amorphizing Si implants during annealing. The in-diffusion of interstitials is limited by trapping at impurities and has an activation energy of {approximately}3.5 eV. Substitutional C is the dominant trapping center with a binding energy of 2--2.5 eV. The high interstitial supersaturation adjacent to the implant damage drives substitutional B into metastable clusters at concentrations below the B solid solubility limit. Transmission electron microscopy shows that the interstitials driving TED are emitted from {l_brace}311{r_brace} defect clusters in the damage region at a rate which ...

1995-12-31

161

Understanding and controlling transient enhanced dopant diffusion in silicon  

International Nuclear Information System (INIS)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during initial annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, the authors have used B doping marker layers in Si to probe the injection of interstitials from near-surface, non-amorphizing Si implants during annealing. The in-diffusion of interstitials is limited by trapping at impurities and has an activation energy of #approx#3.5 eV. Substitutional C is the dominant trapping center with a binding energy of 2--2.5 eV. The high interstitial supersaturation adjacent to the implant damage drives substitutional B into metastable clusters at concentrations below the B solid solubility limit. Transmission electron microscopy shows that the interstitials driving TED are emitted from #left brace#311#right brace# defect clusters in the damage region at a rate which ...

162

The effect of boron implant energy on transient enhanced diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) of boron in silica after low energy boron implantation and annealing was investigated using boron-doping superlattices (DSLs) grown by low temperature molecular beam epitaxy. Boron ions were implanted at 5, 10, 20, and 40 keV at a constant dose of 2{times}10{sup 14}/cm{sup 2}. Subsequent annealing was performed at 750{degree}C for times of 3 min, 15 min, and 2 h in a nitrogen ambient. The broadening of the boron spikes was measured by secondary ion mass spectroscopy and simulated. Boron diffusivity enhancement was quantified as a function of implant energy. Transmission electron microscopy results show that {l_angle}311{r_angle} defects are only seen for implant energies {ge}10 keV at this dose and that the density increases with energy. DSL studies indicate the point defect concentration in the background decays much slower when {l_angle}311{r_angle} defects are ...

1997-02-01

163

Reduction of transient diffusion from 1{endash}5 keV Si{sup +} ion implantation due to surface annihilation of interstitials  

Energy Technology Data Exchange (ETDEWEB)

The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1{times}10{sup 14} cm{sup {minus}2} Si{sup +} was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050{degree}C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si{sup +} ion range is observed at all temperatures, extrapolating to {approximately}1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of {lt}10 nm. The data presented here ...

1997-11-01

164

Reduction of transient diffusion from 1 endash 5 keV Si"+ ion implantation due to surface annihilation of interstitials  

International Nuclear Information System (INIS)

The reduction of transient enhanced diffusion (TED) with reduced implantation energy has been investigated and quantified. A fixed dose of 1x10"1"4 cm"-"2 Si"+ was implanted at energies ranging from 0.5 to 20 keV into boron doping superlattices and enhanced diffusion of the buried boron marker layers was measured for anneals at 810, 950, and 1050 degree C. A linearly decreasing dependence of diffusivity enhancement on decreasing Si"+ ion range is observed at all temperatures, extrapolating to #approx#1 for 0 keV. This is consistent with our expectation that at zero implantation energy there would be no excess interstitials from the implantation and hence no TED. Monte Carlo modeling and continuum simulations are used to fit the experimental data. The results are consistent with a surface recombination length for interstitials of <10 nm. The data presented here demonstrate that in the range of ...

165

Low temperature formation of shallow p{sup +}n junctions by BF{sub 2}{sup +} implantation into thin Pd{sub 2}Si films on Si substrates  

Energy Technology Data Exchange (ETDEWEB)

Excellent silicided shallow p{sup +}n junctions have been successfully achieved by the implantation of BF{sub 2}{sup +} ions into thin Pd{sub 2}Si films on Si substrates to a dose of 5 {times} 10{sup 15} cm{sup {minus}2} and subsequent low temperature (even at 550 C) furnace annealing. The formed junctions have been characterized for respective implantation conditions. In this experiment, the implant energy is the key role in obtaining a low leakage diode. Reverse current density of about 3 nA/cm{sup 2} and an ideality factor of about 1.05 can be attained by the implantation of BF{sub 2}{sup +} ions at 80 keV and subsequent annealing at 550 C. The junction depth is about 0.09 {mu}m, measured by the spread resistance method. As compared with the results of unimplanted specimens, the implantation of BF{sub 2}{sup +} ions into a thin Pd{sub 2}Si layer can stabilize the silicide film ...

1995-05-01

166

Low energy boron implantation in silicon: (1) reduction of channeling tail by careful alignments. (2) Transient diffusion during rapid thermal annealing  

Energy Technology Data Exchange (ETDEWEB)

An attempt was made to minimize the channeling tail by implantation along a random equivalent direction following a careful alignment of the target. In order to analytically determine the random equivalent directions, critical angles for channeling were mapped on a stereogram. Boron ions with energies of 17 and 45 keV are implanted along specified directions determined from the map. The depth distribution of the dopant is profiled by SIMS and the effects of water orientation upon the channeling tail are noted. Industrial common use of a 7/sup 0/ tilt is not optimum. However, implantation with the wafer tilted at 5.5 +/- 0.5/sup 0/ from the surface normal and rotated at 7.0 +/- 0.5/sup 0/ from a (100) plane shows the least channel-tail compared to implantation along other directions. Rapid thermal annealing (RTA) is a promising annealing method for shallow junction formation. Transient enhanced diffusion ...

1985-01-01

167

Low energy boron implantation in silicon: (1) reduction of channeling tail by careful alignments. (2) Transient diffusion during rapid thermal annealing  

International Nuclear Information System (INIS)

An attempt was made to minimize the channeling tail by implantation along a random equivalent direction following a careful alignment of the target. In order to analytically determine the random equivalent directions, critical angles for channeling were mapped on a stereogram. Boron ions with energies of 17 and 45 keV are implanted along specified directions determined from the map. The depth distribution of the dopant is profiled by SIMS and the effects of water orientation upon the channeling tail are noted. Industrial common use of a 7"0 tilt is not optimum. However, implantation with the wafer tilted at 5.5 +/- 0.5"0 from the surface normal and rotated at 7.0 +/- 0.5"0 from a (100) plane shows the least channel-tail compared to implantation along other directions. Rapid thermal annealing (RTA) is a promising annealing method for shallow junction formation. Transient enhanced diffusion of ...

168

Human bone matrix gelatin as a clinical alloimplant. A retrospective review of 160 cases.  

Science.gov (United States)

Bone matrix gelatin, prepared by sequential chemical treatment including decalcification with 0.6 N hydrochloric acid [9], was used as an alloimplant for the treatment of benign bone tumours, tumorous conditions of bone, acetabular dysplasia, delayed union, traumatic bone defects and other disorders. The bone matrix gelatin implanted into bone defects was incorporated successfully in 98% of implantations, excluding cases of infection, tumour recurrence and recurrence of tumorous conditions. The material was also implanted into ten bone sites as an onlay but in five it was resorbed without new bone formation. The incorporation of the bone matrix gelatin into the recipient bed was completed from 6 to 33 months (average 14.9 months) after implantation. Wound infection complicated 5 of 165 implantations (3%) in previously uninfected sites. Low grade fever persisting after the tenth ...

1985-01-01

169

Electrical and structural properties of ion-implanted and post-annealed silicide films  

Energy Technology Data Exchange (ETDEWEB)

The changes in the electrical and structural properties of metal-silicide films caused by ion implantation and subsequent thermal annealing have been investigated. Epitaxial silicide films such as those of CoSi/sub 2/, NiSi/sub 2/ and Pd/sub 2/Si grown on Si(111) substrates were implanted with Ar ions and annealed in a vacuum furnace at temperatures ranging from 200 to 800/sup 0/C. Rutherford backscattering and channeling techniques and the four-point probe method were used to measure the crystalline quality and the sheet resistance of the films, respectively. It was found that the sheet resistances of CoSi/sub 2/, NiSi/sub 2/ and Pd/sub 2/Si films were increased by factors of 70, 6, and 3, respectively, by implantation to a dose of 1 x 10/sup 16/ Ar-ions/cm/sup 2/, but that they were almost restored by subsequent annealing to the values before implantation. A phase transformation from Pd/sub 2/Si to ...

1982-05-01

170

Electrical and structural properties of ion-implanted and post-annealed silicide films  

International Nuclear Information System (INIS)

The changes in the electrical and structural properties of metal-silicide films caused byion implantation and subsequent thermal annealing have been investigated. Epitaxial silicide films such as those of CoSi"2, NiSi"2 and Pd"2Si grown on Si(111) substrates were implanted with Ar ions and annealed in a vacuum furnace at temperatures ranging from 200 to 800_0C. Rutherford backscattering and channeling techniques and the four-point probe method were used to measure the crystalline quality and the sheet resistance of the films, respectively. It was found that the sheet resistances of CoSi"2, NiSi"2 and Pd"2Si films were increased by factors of 70, 6, and 3, respectively, by implantation to a dose of 1 x 10_1_6 Ar-ions/cm_2, but that they were almost restored by subsequent annealing to the values before implantation. A phase transformation from Pd"2Si to PdSi was also observed in the high-temperature ...

171

Diffusion modeling of ion implanted boron in Si during RTA: Correlation of extended defect formation and annealing with the enhanced diffusion of boron. [Rapid Thermal Annealing  

Energy Technology Data Exchange (ETDEWEB)

Accurate modeling of the enhanced diffusion of boron during rapid thermal annealing has been accomplished by incorporating the effects of extended defect formation and annealing on enhanced diffusion into a multizone, semiempirical model. The multizone model divides the implant profile into three zones defining regions of different defects and diffusion enhancements. The model also contains the initial enhanced diffusion and the transient diffusion effects associated with the dissolution of defect clusters and the annealing of extended defects, respectively. The saturation time for transient-enhanced diffusion contains an exponential function of implant dose in order to model the increase in point defect generated with higher implant dose. As a result, the model accurately simulates the boron diffusion profile over a wide range of implant doses and also shows the immobile boron peak of precipitated ...

1993-01-01

172

Defects induced by focused ion beam implantation in GaAs  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of defects induced by Si and Ga focused ion beam (FIB) implantation in n-GaAs have been investigated by means of deep-level transient spectroscopy (DLTS), C--V carrier profiling, and resistance measurements. The DLTS spectra of Si and Ga FIB implanted samples annealed at temperatures up to 500 /sup 0/C are apparently identical to one another and show three different electron traps with an activation energy between 0.25 and 0.6 eV. The resistance increases by more than five orders of magnitude by Si and Ga FIB implantation due to the induced defects. However, it is restored to initial values after annealing at 600 /sup 0/C, except for a sample of Ga implantation with a dose higher than 10/sup 14/ cm/sup 2/ . For annealing of induced defects, there are no intrinsic problems for FIB implantation with a dose lower than 10/sup 13/ cm/sup 2/ .

1988-05-01

173

Defects induced by focused ion beam implantation in GaAs  

International Nuclear Information System (INIS)

The characteristics of defects induced by Si and Ga focused ion beam (FIB) implantation in n-GaAs have been investigated by means of deep-level transient spectroscopy (DLTS), C--V carrier profiling, and resistance measurements. The DLTS spectra of Si and Ga FIB implanted samples annealed at temperatures up to 500 "0C are apparently identical to one another and show three different electron traps with an activation energy between 0.25 and 0.6 eV. The resistance increases by more than five orders of magnitude by Si and Ga FIB implantation due to the induced defects. However, it is restored to initial values after annealing at 600 "0C, except for a sample of Ga implantation with a dose higher than 10"1"4 cm"2 . For annealing of induced defects, there are no intrinsic problems for FIB implantation with a dose lower than 10"1"3 cm"2.

174

Current trends in ion implantation  

Energy Technology Data Exchange (ETDEWEB)

As semiconductor device dimensions continue to shrink, the drive beyond 250 nm is creating significant problems for the device processor. In particular, trends toward shallower-junctions, lower thermal budgets and simplified processing steps present severe challenges to ion implantation. In parallel with greater control of the implant process goes the need for a better understanding of the physical processes involved during implantation and subsequent activation annealing. For instance, the need for an understanding of dopant-defect interaction is paramount as defects mediate a number of technologically important phenomena such as transient enhanced diffusion and impurity gettering. This paper will outline the current trends in the ion implantation and some of the challenges it faces in the next decade, as described in the semiconductor roadmap. It will highlight some recent positron annihilation work ...

2001-07-01

175

Anomalous phosphorus diffusion in Si during postimplantation annealing  

Energy Technology Data Exchange (ETDEWEB)

The transient behavior of P diffusion in Si implanted with As or Ge above the amorphizing threshold has been investigated. Annealing at 720{degree}C after Ge implantation induces extensive P segregation into the extended defect layer formed by implantation damage. This segregation is attributed to P trapping to end-of-range {l_brace}311{r_brace} defects and dislocation loops. For As implantation, P segregation was also observed only after 1 min annealing. However, in contrast to the Ge implantation, in the As-implanted samples, significant P depletion occurs in the As-tail region after further annealing. Nonequilibrium simulation that takes into account both Fermi-level and electric field effects shows the P depletion during transient enhanced diffusion. Furthermore, simulation results based on the coexistence of neutral and positively charged ...

2001-06-11

176

Annealing and diffusion characteristics of boron-through-oxide implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

The author investigates the diffusion and damage-annealing characteristics as a result of boron implantation through a surface oxide into the silicon, a process that is commonly realized in the fabrication of p-n junctions. Defect structures were examined using plan-view and cross-section transmission-electron microscopies. It is shown that recoil-implanted oxygen plays a critical role in determining the above annealing characteristics. For instance, transient-enhanced diffusion of boron, as is widely observed for boron-implanted silicon, does not occur in the case of through-oxide implantation. The initial suppression of the defect-enhanced diffusion lasts for a limited period of time after which enhanced diffusion occurs again. The so-called incubated enhanced diffusion' is characterized as due to recoiled-oxygen precipitation-emitting point defect that enhances boron motion. The incubation ...

1991-01-01

177

Annealing and diffusion characteristics of boron-through-oxide implanted silicon  

International Nuclear Information System (INIS)

The author investigates the diffusion and damage-annealing characteristics as a result of boron implantation through a surface oxide into the silicon, a process that is commonly realized in the fabrication of p-n junctions. Defect structures were examined using plan-view and cross-section transmission-electron microscopies. It is shown that recoil-implanted oxygen plays a critical role in determining the above annealing characteristics. For instance, transient-enhanced diffusion of boron, as is widely observed for boron-implanted silicon, does not occur in the case of through-oxide implantation. The initial suppression of the defect-enhanced diffusion lasts for a limited period of time after which enhanced diffusion occurs again. The so-called incubated enhanced diffusion' is characterized as due to recoiled-oxygen precipitation-emitting point defect that enhances boron motion. The incubation time ...

178

A detailed physical model for ion implant induced damage in silicon  

Energy Technology Data Exchange (ETDEWEB)

A unified physically based ion implantation damage model has been developed which successfully predicts both the impurity profiles and the damage profiles for a wide range of implant conditions for arsenic, phosphorus, BF{sub 2}, and boron implants into single-crystal silicon. In addition, the amorphous layer thicknesses predicted by this new damage model are also in excellent agreement with experimental measurements. This damage model is based on the physics of point defects in silicon, and explicitly simulates the defect production, diffusion, and their interactions which include interstitial-vacancy recombination, clustering of same type of defects, defect-impurity complex formation, emission of mobile defects from clusters, and surface effects for the first time. New computationally efficient algorithms have been developed to overcome the barrier of the excessive computational requirements. In addition, the new model ...

1998-06-01

179

A detailed physical model for ion implant induced damage in silicon  

International Nuclear Information System (INIS)

A unified physically based ion implantation damage model has been developed which successfully predicts both the impurity profiles and the damage profiles for a wide range of implant conditions for arsenic, phosphorus, BF_2, and boron implants into single-crystal silicon. In addition, the amorphous layer thicknesses predicted by this new damage model are also in excellent agreement with experimental measurements. This damage model is based on the physics of point defects in silicon, and explicitly simulates the defect production, diffusion, and their interactions which include interstitial-vacancy recombination, clustering of same type of defects, defect-impurity complex formation, emission of mobile defects from clusters, and surface effects for the first time. New computationally efficient algorithms have been developed to overcome the barrier of the excessive computational requirements. In addition, the new model has ...

1998-06-01

180

Urinary tract infection in children.  

UK PubMed Central (United Kingdom)

During 1968-77, 572 consecutive children with one or more positive urine cultures who were referred by their family doctors to one paediatric surgical outpatient clinic were investigated and prospectively...Full Text Available

1984-08-04

181

Urinary symptoms and impact on quality of life in women after treatment for endometrial cancer  

UK PubMed Central (United Kingdom)

The primary objective of our study is to describe urinary symptoms in women treated for endometrial cancer. We performed a cross-sectional survey of women who had undergone surgical treatment...Full Text Available

2009-02-01

182

Tracheo-innominate artery erosion: Successful surgical management of a devastating complication.  

UK PubMed Central (United Kingdom)

Successful management of a patient with tracheo-innominate artery erosion requires the rapid institution of specific resuscitative and operative measures. Ten patients seen at the Charity Hospital of...Full Text Available

1976-08-01

183

The CORONIS Trial. International study of caesarean section surgical techniques: a randomised fractional, factorial trial  

UK PubMed Central (United Kingdom)

BackgroundCaesarean section is one of the most commonly performed operations on women throughout the world. Rates have increased in recent years – about 20–25% in...Full Text Available

184

Surgical management and outcome analysis of stage III pediatric empyema thoracis  

UK PubMed Central (United Kingdom)

Aim:Report of 125 pediatric patients of empyema thoracis treated by open decortication, highlighting the presentation, delay in referral, operative findings, the response...Full Text Available

2010-01-01

185

Surgical Management of Solid-Pseudopapillary Neoplasms of the Pancreas (Franz or Hamoudi Tumors): A Large Single-Institutional Series  

UK PubMed Central (United Kingdom)

BACKGROUNDSolid-pseudopapillary neoplasms (SPNs) are rare pancreatic tumors with malignant potential. Clinicopathologic characteristics and outcomes of patients with...Full Text Available

2009-05-01

186

Surgery for hip fractures: Does surgical delay affect outcomes?  

UK PubMed Central (United Kingdom)

Hip fractures are associated with a high rate of mortality and profound temporary and sometimes permanent impairment of quality of life. Current guidelines indicate that surgeons should perform surgery...Full Text Available

2011-01-01

187

Spinal Cord Stimulation for Intractable Visceral Pain due to Chronic Pancreatitis  

UK PubMed Central (United Kingdom)

Pain caused by chronic pancreatitis is medically intractable and resistant to conventional interventional or surgical treatment. We report a case of spinal cord stimulation (SCS) for intractable pain...Full Text Available

2009-08-01

188

Single-Hair Follicular Unit Transplant for Stable Vitiligo  

UK PubMed Central (United Kingdom)

Follicular unit transplant (FUT) is one of the surgical procedures which has been recently used to repigment a stable vitiligo patch. Single-hair FUT was done for a 30-year-old male with stable vitiligo...Full Text Available

2011-01-01

189

Sigma-1 receptor agonist fluvoxamine for postoperative delirium in older adults: report of three cases  

UK PubMed Central (United Kingdom)

BackgroundPostoperative delirium is a topic of great importance in the geriatric surgical specialty. Although antipsychotic drugs are the medications most frequently used to treat...Full Text Available

190

Scalp Angiosarcoma Remission with Bevacizumab and Radiotherapy without Surgery: A Case Report and Review of the Literature  

UK PubMed Central (United Kingdom)

Angiosarcoma (AS) is a rare and aggressive vascular neoplasm with very poor prognosis. Patients with extensive cutaneous AS who are not surgical candidates have very limited options since there is no...Full Text Available

2011-01-01

191

Quality-of-Life and Surgical Treatments for Rectal Cancer-a Longitudinal Analysis Using the California Cancer Registry  

UK PubMed Central (United Kingdom)

BackgroundHeterogeneous results for research investigating health-related quality of life (HRQL) in patients undergoing sphincter-ablating procedures for rectal cancer...Full Text Available

2010-08-01

192

Progress in Treatment of Thoracoabdominal and Abdominal Aortic Aneurysms Involving Celiac, Superior Mesenteric, and Renal Arteries  

UK PubMed Central (United Kingdom)

This is a report of surgical treatment of thoracoabdominal aortic aneurysms and aneurysms of the abdominal aorta from which the visceral vessels arise during the 18 year period from April 5, 1960,...Full Text Available

1978-09-01

193

Prognostic determinants for survival after resection/ablation of a large hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

Background:Liver resection of large hepatocellular carcinomas (HCC), measuring at least 10 cm remains a controversial debate. Multiple studies on HCCs treated with surgical resection...Full Text Available

2009-06-01

194

Positional Stretching of the Coracohumeral Ligament on a Patient with Adhesive Capsulitis: A Case Report  

UK PubMed Central (United Kingdom)

Idiopathic frozen shoulder is a common medical diagnosis for patients seeking physical therapy. Radiographic and surgical evidence exists that describes the coracohumeral ligament (CHL) as a major contributor...Full Text Available

2009-01-01

195

Percutaneous endoscopic lumbar discectomy for migrated disc herniation: classification of disc migration and surgical approaches  

UK PubMed Central (United Kingdom)

Percutaneous endoscopic lumbar discectomy (PELD) for migrated disc herniations is technically demanding due to the absence of the technical guideline. The purposes of this study were to propose a radiologic...Full Text Available

2007-03-01

196

Pain and pain-related interference in adults with lower-limb amputation: Comparison of knee-disarticulation, transtibial, and transfemoral surgical sites  

UK PubMed Central (United Kingdom)

Pain and pain-related interference with physical function have not been thoroughly studied in individuals who have undergone knee-disarticulation amputations. The principal aim of this study...Full Text Available

2009-01-01

197

PLESIOTHERAPY FOR NON-MELANOMA SKIN CANCER: INNOVATING TO OVERCOME!  

UK PubMed Central (United Kingdom)

Background:The non-surgical management of non-melanoma skin cancers is an area requiring clinical investigation. Radiotherapy has a role in treatment for a defined subset...Full Text Available

2010-10-01

198

Nonsteroidal Selective Androgen Receptor Modulators Enhance Female Sexual Motivation  

UK PubMed Central (United Kingdom)

Women experience a decline in estrogen and androgen levels after natural or surgically induced menopause, effects that are associated with a loss of sexual desire and bone mineral density. Studies in...Full Text Available

2010-08-01

199

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D ...

2008-04-15

200

Medico-legal autopsy in postoperative hemodynamic collapse following coronary artery bypass surgery  

UK PubMed Central (United Kingdom)

Sudden unexpected postoperative hemodynamic collapse with a high mortality develops in 1–3% of patients undergoing coronary artery bypass surgery (CABG). The contribution of surgical graft complications...Full Text Available

2011-03-01

201

Management of poor-prognosis testicular germ cell tumors  

UK PubMed Central (United Kingdom)

Currently, the outcome of patients with intermediate-and poor-risk germ cell tumors at diagnosis is optimized by the use of risk-appropriate chemotherapy and post-chemotherapy surgical resection of...Full Text Available

2010-01-01

202

MR findings in acute Lyme disease affecting the knee. A case report  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report a case with primarily unspecific arthralgia after surgical therapy of hallux valgus deformity and consecutive reflex sympathetic dystrophy in which MR led to the diagnosis of Lyme disease. (orig.)

2002-07-01

203

Low-frequency sound transmission through a g... [J Acoust Soc...  

Science.gov (United States)

and antibody responses of rhesus macaques exposed to the human gammaretrovirus XMRV. J Virol. 2011 May ;85(9):4547-57. Epub 2011 Feb 16 . PubMed Surgical staging of early...

2011-10-15

204

Long-term disease-free survival after surgical resection for multiple bone metastases from rectal cancer  

UK PubMed Central (United Kingdom)

Bone metastasis of primary colorectal cancer is uncommon. When it occurs, it is usually a late manifestation of disease and is indicative of poor prognosis. We describe a patient with multiple metachronous...Full Text Available

2011-08-10

205

Investigation and management of adrenal disease  

British Library Electronic Table of Contents (United Kingdom)

Disorders of the adrenal gland are rare and complex, with many potential pitfalls in their management. An understanding of embryology, anatomy, physiology and biochemistry is crucial. Surgical treatment may be required for syndromes of hormonal excess and/or suspicion of neoplasia.

2011-01-01

206

Intraoperative and external beam irradiation for locally advanced colorectal cancer.  

UK PubMed Central (United Kingdom)

In view of poor local control rates obtained with standard treatment, intraoperative radiation (IORT) using electrons was combined with external beam irradiation and surgical resection, with or without...Full Text Available

1988-01-01

207

Impact of periodic health examination on surgical treatment for uterine fibroids in Beijing: a case-control study  

UK PubMed Central (United Kingdom)

BackgroundDuring the past 2 decades, there has been a rapid proliferation of "health examination center (HEC)" across China. The effects of their services on public's health have...Full Text Available

208

Giant Lipoma of Posterior Neck with Bleeding Decubitus Ulcer: A Rare Entity  

UK PubMed Central (United Kingdom)

Giant lipomas are benign soft tissue tumours. They are found relatively rarely on the posterior part of the neck. Bleeding pressure ulcer in this giant tumour is a rare presentation. Surgical interventions...Full Text Available

2010-05-01

209

Familial occurrence of unilateral giant breasts in Nigeria: a possible new genetic entity.  

UK PubMed Central (United Kingdom)

Four cases of unilateral giant breasts from two unrelated families are described. Three of the patients were managed surgically. It is speculated from a review of available published reports that this...Full Text Available

1984-04-01

210

Effect of Surgical Alteration of the Rat Gastrointestinal Tract On the Growth and Development of Hymenolepis Diminuta  

Science.gov (United States)

... Gastrointestinal Tract On the Growth and Development of Hymenolepis DiminutaKerry L. Dwinell, Paul Bass, Gordon L. Telford, ... central (CNS) nervous systems in the development of Hymenolepis diminuta usi...

211

Diagnostic Dilemma in an Unusual Case of Common Bile Duct Obstruction  

UK PubMed Central (United Kingdom)

Biliary obstructions are rarely caused by a foreign body and have received sparse attention. We present an unusual case with pruritis and abdominal pain caused by impacted full length surgical gauze...Full Text Available

2011-06-01

212

Design of the Endobronchial Valve for Emphysema Palliation Trial (VENT): a non-surgical method of lung volume reduction  

UK PubMed Central (United Kingdom)

BackgroundLung volume reduction surgery is effective at improving lung function, quality of life, and mortality in carefully selected individuals with advanced emphysema. Recently,...Full Text Available

213

Congenital anal anomalies in two families with the Opitz G syndrome.  

UK PubMed Central (United Kingdom)

Five children from two families presented to a regional neonatal surgical unit between 1959 and 1984 with congenital anal anomalies and other malformations resulting from an autosomal dominant inherited...Full Text Available

1987-11-01

214

Clinical Strategy for the Management of Solid Pseudopapillary Tumor of the Pancreas: Aggressive or Less?  

UK PubMed Central (United Kingdom)

Objective: To further delineate the clinicopathological and radiological features of solid pseudopapillary tumor (SPT) of the pancreas and summarize the surgical therapy strategy for this tumor. Methods:...Full Text Available

215

Clinical Features and Treatments of Upper Lumbar Disc Herniations  

UK PubMed Central (United Kingdom)

ObjectiveDisc herniations at the L1-L2 and L2-L3 levels are different from those at lower levels of the lumbar spine with regard to clinical characteristics and surgical outcome....Full Text Available

2010-08-01

216

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

217

CT evaluation of acetabular fractures  

International Nuclear Information System (INIS)

The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

1986-01-01

218

Appearance of beta-endorphin-like immunoreactivity in human ventricular cerebrospinal fluid upon analgesic electrical stimulation.  

UK PubMed Central (United Kingdom)

beta-Endorphin-like immunoreactivity in human ventricular cerebrospinal fluid was measured with a specific radioimmunoassay. The subjects were undergoing a surgical procedure for relief of chronic intractable...Full Text Available

1978-10-01

219

Adult Morgagni Hernia: The Need for Clinical Awareness, Early Diagnosis and Prompt Surgical Intervention  

UK PubMed Central (United Kingdom)

We report an unusual case of strangulated diaphragmatic (Morgagni) hernia resulting in ischaemia of the small and large bowel, which was initially diagnosed as a pneumonia. This case highlights the...Full Text Available

2008-11-01

220

A randomized-controlled trial of low-dose doxycycline for periodontitis in smokers  

UK PubMed Central (United Kingdom)

Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available

2007-04-01

221

A non-invasive technique for standing surgical repair of urinary bladder rupture in a post-partum mare: a case report  

UK PubMed Central (United Kingdom)

An 11-year-old mare presented 36 hours after foaling with a ruptured bladder. Uroperitoneum was diagnosed on ultrasound and from the creatinine concentration of the peritoneal fluid. Bladder endoscopy...Full Text Available

222

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

223

Self-interstitial supersaturation during Ostwald ripening of end-of-range defects in ion-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

Modified Ostwald ripening theory is used to calculate the time evolution of the size distribution function of extended end-of-range defects in ion implanted silicon. This allows the authors to compare the time dependent self-interstitial supersaturation during post-implantation annealing in the presence of Frank-type stacking faults with that in the presence of {l_brace}311{r_brace}-defects. It is shown that the latter affect self-interstitial concentrations up to the point where they dissolve whereas the former are irrelevant from the point of view of transient enhanced diffusion.

1996-12-01

224

Precipitation, phase transformation, and enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

This paper describes Z-contrast scanning transmission electron microscopy used to study the connection between dopant precipitation and phase transformation in high dose In"+ and Sb"+ implanted Si. In the case of In, the observations confirm a heterogeneous nucleation model. Images of the precursor precipitates give the first measurement of the diffusion coefficient in amorphous Si, with an enhancement of 10"7 over tracer crystalline values. With Sb"+ implants enhanced homogeneous nucleation is observed. The connection between these results and the transient enhanced diffusion observed in crystallized Si is discussed.

225

Plasma immersion ion implantation. (Latest citations from the EI Compendex*plus database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning plasma immersion ion implantation (PIII) and equipment. PIII is a new technique to implant plasma ions into materials for surface modification and treatment. Topics include plasma nitriding, semiconductor doping, ion energy distribution, ion dose, pulsed plasma, metal plasma, and defect passivation. References also review applications in semiconductor device and integrated circuit manufacture, silicon material fabrication, aerospace bearings, carbon coatings on metals, and ceramic coatings. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

1998-01-01

226

Nanostructure of Si-Ge near-surface layers produced by ion implantation and laser annealing  

International Nuclear Information System (INIS)

An annealing with the nanosecond laser light pulse is applied for crystal lattice reconstruction of a disturbed near-surface layer, which was created in semiconductor material as a result of the implantation process. Radiation with energy density higher than the threshold value causes the melting of the surface layer and than the epitaxial recrystallization from the melt on a different substrate. Structural changes occurring in the Ge implanted Si crystals after annealing with different energy densities are investigated by means of the cross-section high-resolution transmission electron microscopy. (author)

2001-09-23

227

Modeling of dislocation loop growth and transient enhanced diffusion in silicon for amorphizing implants  

Energy Technology Data Exchange (ETDEWEB)

It has been observed that dislocation loops form and grow during annealing of silicon wafers implanted at doses above the amorphization threshold. Dislocation loops can act to store interstitials for prolonged periods of anneals, sustaining an interstitial super-saturation and thus causing substantial transient enhanced diffusion (TED). The authors have developed a comprehensive model which, in combination with a model and parameters for {l_brace}311{r_brace} defects from previous work, accounts for the formation and evolution of dislocation loops during ion implant annealing, as well as giving the correct TED behavior.

1997-11-01

228

Modeling of dislocation loop growth and transient enhanced diffusion in silicon for amorphizing implants  

International Nuclear Information System (INIS)

It has been observed that dislocation loops form and grow during annealing of silicon wafers implanted at doses above the amorphization threshold. Dislocation loops can act to store interstitials for prolonged periods of anneals, sustaining an interstitial super-saturation and thus causing substantial transient enhanced diffusion (TED). The authors have developed a comprehensive model which, in combination with a model and parameters for #left brace#311#right brace# defects from previous work, accounts for the formation and evolution of dislocation loops during ion implant annealing, as well as giving the correct TED behavior.

1996-12-02

229

Application of high energy ion beam for the control of boron diffusion  

Energy Technology Data Exchange (ETDEWEB)

For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10{sup 15} to 1 x 10{sup 16} cm{sup -2}. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.

2006-01-15

230

Application of high energy ion beam for the control of boron diffusion  

International Nuclear Information System (INIS)

For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10"1"5 to 1 x 10"1"6 cm"-"2. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.

2006-01-01

231

A spatial damage energy distribution calculation for ion-implanted materials  

International Nuclear Information System (INIS)

A simple method allowing easy calculation of the spatial damage energy distributions for ion-implanted materials is presented. The direct procedure takes account of the variation with depth of the lateral spreading of implanted ions, as well as the effects of energy transport by the recoiling target atoms. The subsequent computer program LUPIN-3D provides three-dimensional damage distributions and allows the construction of damage energy mappings. Various substrates of technological interest are investigated and several fields of application of the calculation are envisaged. The density of cascades can therefore be determined and heterogeneous amorphization models can be implemented. (orig.).

1989-01-01

232

Prognostic implications of pulmonary hypertension in patients with severe aortic stenosis  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveWe sought to determine the clinical outcomes of patients undergoing surgical aortic valve replacement with hemodynamically confirmed severe pulmonary hypertension and aortic stenosis and compare them with the outcomes of patients not undergoing aortic valve replacement and patients undergoing aortic valve replacement with mild-to-moderate pulmonary hypertension. MethodsA total of 317 patients with severe aortic stenosis (aortic valve area 35 mm Hg) was present in 81 patients, of whom 35 (43.2%) underwent surgical aortic valve replacement. We compared the clinical outcomes of these 35 patients with the 46 patient...

2011-01-01

233

Field surgery on a future conventional battlefield: strategy and wound management.  

Science.gov (United States)

Most papers appearing in the surgical literature dealing with wound ballistics concern themselves with wound management in the civilian setting. The pathophysiology of modern war wounds is contrasted with ballistic wounds commonly encountered in peacetime, but it should be noted that even in peacetime the modern terrorist may have access to sophisticated military weaponry, and that patients injured by them may fall within the catchment area of any civilian hospital. Management problems associated with both wound types are highlighted; areas of controversy are discussed. The orthodox military surgical approach to ballistic wounds is expounded and defended. PMID:1996857

1991-01-01

234

Efficient application of medical imaging methods. Graded diagnostics for surgical and internal medical problems. Rationeller Einsatz bildgebender Verfahren. Gestufte Diagnostik bei chirurgischen und internistischen Krankheitsbildern  

Energy Technology Data Exchange (ETDEWEB)

The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.

1985-01-01

235

Transient-enhanced diffusion during furnace and rapid thermal annealing of ion-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

A transient-enhanced diffusion has been observed during the furnace or rapid thermal annealing of ion-implanted silicon. We have studied this transient in detail and show that, for doses of Group V dopants sufficient to amorphize the silicon, it arises from the trapping of interstitials by dopant atoms during implantation. These are retained during solidphase-epitaxial (SPE) growth, but can be released by additional thermal processing to cause the observed transient and the formation of a band of extended defects. We have measured the enhanced diffusion coefficients and the duration of the transient for Sb-implanted Si by careful furnace annealing experiments. We obtain general expressions which predict the effects of the transient during any thermal processing based on SPE growth (furnace, CW laser, or rapid thermal annealing). We show that there is no analogous mechanism of vacancy trapping by Group III elements.

1985-08-01

236

Transient-enhanced diffusion during furnace and rapid thermal annealing of ion-implanted silicon  

International Nuclear Information System (INIS)

A transient-enhanced diffusion has been observed during the furnace or rapid thermal annealing of ion-implanted silicon. We have studied this transient in detail and show that, for doses of Group V dopants sufficient to amorphize the silicon, it arises from the trapping of interstitials by dopant atoms during implantation. These are retained during solidphase-epitaxial (SPE) growth, but can be released by additional thermal processing to cause the observed transient and the formation of a band of extended defects. We have measured the enhanced diffusion coefficients and the duration of the transient for Sb-implanted Si by careful furnace annealing experiments. We obtain general expressions which predict the effects of the transient during any thermal processing based on SPE growth (furnace, CW laser, or rapid thermal annealing). We show that there is no analogous mechanism of vacancy trapping by Group III elements.

237

Transient enhanced diffusion and gettering of dopants in ion implanted silicon  

International Nuclear Information System (INIS)

We have studied in detail the transient enhanced diffusion observed during furnace or rapid-thermal-annealing of ion-implanted Si. We show that the effect originates in the trapping of Si atoms by dopant atoms during implantation, which are retained during solid-phase-epitaxial (SPE) growth but released by subsequent annealing to cause a transient dopant precipitation or profile broadening. The interstitials condense to form a band of dislocation loops located at the peak of the dopant profile, which may be distinct from the band formed at the original amorphous/crystalline interface. The band can develop into a network and effectively getter the dopant. We discuss the conditions under which the various effects may or may not be observed, and discuss conflicting observations on As"+ implanted Si.

1984-11-26

238

Transient enhanced diffusion and gettering of dopants in ion implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

The authors have studied in detail the transient enhanced diffusion observed during furnace or rapid-thermal-annealing of ion-implanted Si. The authors show that the effect originates in the trapping of Si atoms by dopant atoms during implantation, which are retained during solid-phase epitaxial (SPE) growth but released by subsequent annealing to cause a transient dopant precipitation or profile broadening. The interstitials condense to form a band of dislocation loops located at the peak of the dopant profile, which may be distinct from the band formed at the original amorphous/crystalline interface. The band can develop into a network and effectively getter the dopant. They discuss the conditions under which the various effects may or may not be observed, and discuss preliminary observations on As/sup +/ implanted Si. 12 references, 12 figures.

1986-01-01

239

Transient enhanced diffusion and gettering of dopants in ion implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

We have studied in detail the transient enhanced diffusion observed during furnace or rapid-thermal-annealing of ion-implanted Si. We show that the effect originates in the trapping of Si atoms by dopant atoms during implantation, which are retained during solid-phase-epitaxial (SPE) growth but released by subsequent annealing to cause a transient dopant precipitation or profile broadening. The interstitials condense to form a band of dislocation loops located at the peak of the dopant profile, which may be distinct from the band formed at the original amorphous/crystalline interface. The band can develop into a network and effectively getter the dopant. We discuss the conditions under which the various effects may or may not be observed, and discuss conflicting observations on As/sup +/ implanted Si.

1984-01-01

240

Transient enhanced diffusion and gettering of dopants in ion implanted silicon  

International Nuclear Information System (INIS)

The authors have studied in detail the transient enhanced diffusion observed during furnace or rapid-thermal-annealing of ion-implanted Si. The authors show that the effect originates in the trapping of Si atoms by dopant atoms during implantation, which are retained during solid-phase epitaxial (SPE) growth but released by subsequent annealing to cause a transient dopant precipitation or profile broadening. The interstitials condense to form a band of dislocation loops located at the peak of the dopant profile, which may be distinct from the band formed at the original amorphous/crystalline interface. The band can develop into a network and effectively getter the dopant. They discuss the conditions under which the various effects may or may not be observed, and discuss preliminary observations on As"+ implanted Si. 12 references, 12 figures.

241

The effect of ion implantation of Ar on the aqueous corrosion resistance of Zr-4 alloy  

International Nuclear Information System (INIS)

The effect of ion implantation on the aqueous corrosion resistance of Zr-4 in deaerated 1N H_2SO_4 was studied with the potentiokinetic technique. The Zr-4 alloy was bombarded with 5x10"1"4-2x10"1"6 Ar/cm"2 of 190 keV. It was found that the passive current density of Zr-4 decreases with increasing implantation dose. Photoelectrochemical results show that the ion implantation of Ar in Zr-4 raises the flatband potential of its passive film. AES was employed to analyze the surface of the passive film of Zr-4. The decrease in passive current density may be attributed to a thickening oxide layer on Zr-4 and a decrease in concentration of oxygen vacancies in its passive film. ((orig.)).

242

Surgeons' beliefs and perceptions about removal of orthopaedic implants  

UK PubMed Central (United Kingdom)

BackgroundThe routine removal of orthopaedic fixation devices after fracture healing remains an issue of debate. There are no evidence-based guidelines on this matter, and little...Full Text Available

243

Suppression of transient enhanced diffusion following {ital in} {ital situ} photoexcitation during boron ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The effect of {ital in} {ital situ} photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B{sup +} implantation at 35 keV for a dose of 5{times}10{sup 14} cm{sup {minus}2} at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 {degree}C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 {degree}C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

1995-10-09

244

Suppression of transient enhanced diffusion following in situ photoexcitation during boron ion implantation  

International Nuclear Information System (INIS)

The effect of in situ photoexcitation during boron ion implantation on subsequent transient enhanced B diffusion in Si has been investigated. Photoexcitation using a mercury arc lamp was performed during B"+ implantation at 35 keV for a dose of 5x10"1"4 cm"-"2 at 177 K. A reduction in the electrical activation dip, i.e., reverse annealing effect, in the temperature range 550--700 degree C was observed. Also, the transient enhanced diffusion of B, measured using SIMS following 800 degree C, 30 min annealing, was suppressed. Both effects demonstrate that the creation of self-interstitials during the implantation process is significantly reduced. copyright 1995 American Institute of Physics.

245

Selective radiochemical separation for indium determination at ppb levels in ion-implanted semiconductor-grade silicon  

Energy Technology Data Exchange (ETDEWEB)

A specific radiochemical procedure for indium determination in semiconductor-grade silicon, using an inorganic ion exchanger (cerium oxalate) is proposed.

1982-12-23

247

Plasma processing: a novel method to reduce the transient enhanced diffusion of boron implanted in silicon  

International Nuclear Information System (INIS)

In this paper a novel method is presented, based on the use of plasma processing, to suppress the transient enhanced diffusion of boron implanted in silicon. We found for silicon samples processed with plasma and subsequently boron implanted that the anomalous diffusion of the dopant atoms at the beginning of the annealing process is almost completely suppressed. This phenomenon is interpreted in terms of capture of the ion beam generated interstitials by the dislocations induced by the plasma processing. At room temperature the dislocations are observed to grow in size after the boron implant, attesting their efficiency as trapping centres for interstitials. Moreover, varying the plasma process conditions we can establish a general relation between the presence of the trapping centres induced by the plasma processing and the suppression of the transient diffusion.

1999-01-01

248

Optical and Structural Characteristics of Heavily Boron ...  

Science.gov (United States)

... Abstract : Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. ...

1988-05-24

249

NASA partners with teacher institute NASA strives to improve computers  

Science.gov (United States)

of the digital hearing aid technology that led to the cochlear implant. Former. Marshall Space Flight Center engineers. John Richardson and Joseph Howard ...

250

Microradiographic examination with the mammographic device 'TUR' after enossal implantation of glass ceramics (bio-vitroceramics)  

International Nuclear Information System (INIS)

As to all sinter variations the microradiographic analysis showed that about 86 to 90 % of the implant surface were enclosed split-free with newly formed bone 16 weeks post operationem. A silicat salt addition of the test variation Ap_4_0KS_1_5 and Ap_4_0KS_3_0 did not cause a negative influence on bone regeneration. On the surface of all test implants a double layer was revealed radiologically, consisting of a 30 - 40 #mu#m thick bone near X-ray impermeable area and an X-ray permeable area of maximum 120 #mu#m thickness directed to the nucleus of the implant.

251

Microradiographic examination with the mammographic device 'TUR' after enossal implantation of glass ceramics (bio-vitroceramics)  

Energy Technology Data Exchange (ETDEWEB)

As to all sinter variations the microradiographic analysis showed that about 86 to 90 % of the implant surface were enclosed split-free with newly formed bone 16 weeks post operation. A silicate salt addition of the test variation Ap/sub 40/KS/sub 15/ and Ap/sub 40/KS/sub 30/ did not cause a negative influence on bone regeneration. On the surface of all test implants a double layer was revealed radiologically, consisting of a 30 - 40 ..mu..m thick bone near X-ray impermeable area and an X-ray permeable area of maximum 120 ..mu..m thickness directed to the nucleus of the implant.

1984-01-01

252

Enhancement of electrical conductivity of ion-implanted polymer films  

Energy Technology Data Exchange (ETDEWEB)

The electrical conductivity of ion-implanted films of Nylon 66, Polypropylene (PP), Poly(tetrafluoroethylene) (Teflon) and mainly Poly (ethylene terephthalate) (PET) was determined by DC measurements at voltages up to 4500 V and compared with the corresponding values of pristine films. Measurements were made at 21/sup 0/C +/- 1/sup 0/C and 65 +/- 2% RH. The electrical conductivity of PET films implanted with F/sup +/, Ar/sup +/, or As/sup +/ ions at energies of 50 keV increases by seven orders of magnitude as the fluence increases from 1 x 10/sup 18/ to 1 x 10/sup 20/ ions/m/sup 2/. The conductivity of films implanted with As/sup +/ was approximately one order greater than those implanted with Ar/sup +/, which in turn was approximately one-half order greater than those implanted with F/sup +/. The conductivity of the most conductive film approx.1 S/m) was almost 14 orders of ...

1985-01-01

253

Early Loading after 21 Days of Healing of Nonsubmerged Titanium Implants with a Chemically Modified Sandblasted and Acid-Etched Surface: Two-Year Results of a Prospective Two-Center Study  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT Purpose: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. Material and Methods: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations i...

2010-01-01

254

Diffusion of antimony in silicon in the presence of point defects  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the diffusion of Sb in Si in the presence of defects injected by high-energy implantation of Si ions at room temperature. MeV ion implantation increases the concentrations of vacancies, which induce transient-enhanced diffusion of Sb deposited in Si. We observed a significant enhancement of Sb diffusion. Secondary ions mass spectroscopy has been performed on the implanted samples before and after annealing. Rutherford-backscattering spectrometry has been used to characterize the high-energy implantation damage. By fitting diffusion profiles to a linear diffusive model, information about atomic scale diffusion of Sb, i.e. the generation rate of mobile state Sb and its mean migration length were extracted.

2007-08-15

255

Diffusion of antimony in silicon in the presence of point defects  

International Nuclear Information System (INIS)

We have investigated the diffusion of Sb in Si in the presence of defects injected by high-energy implantation of Si ions at room temperature. MeV ion implantation increases the concentrations of vacancies, which induce transient-enhanced diffusion of Sb deposited in Si. We observed a significant enhancement of Sb diffusion. Secondary ions mass spectroscopy has been performed on the implanted samples before and after annealing. Rutherford-backscattering spectrometry has been used to characterize the high-energy implantation damage. By fitting diffusion profiles to a linear diffusive model, information about atomic scale diffusion of Sb, i.e. the generation rate of mobile state Sb and its mean migration length were extracted.

2007-08-01

256

Depth Profiling of N and C in Ion Implanted ZnO and Si Using Deuterium Induced Nuclear Reaction Analysis  

International Nuclear Information System (INIS)

Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x1014 ions cm-2. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm-1 compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced 12C(d,p)13C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion ...

2008-11-03

257

Crystal Chemistry of Ceramic/Mineral Systems  

Science.gov (United States)

... 1. Reeber, RR, Kusy, RP, Yu, N. and Chu, WK " Formation of a Solid Lubricant in Boron Carbide by Nitrogen Ion Implantation and Laser Annealing ...

1992-12-08

258

Creation of nitrogen-vacancy centres in diamond with high resolution  

International Nuclear Information System (INIS)

Nowadays, diamond and the nitrogen-vacancy (NV) colour centres constitute the best solid-state system in view of quantum-computing applications. It has also been shown recently that single NV centres could be used as nanoscale magnetic sensors. Such applications require the creation of single NV centres with very high resolution and with a high efficiency. The nano-implanter at the university of Bochum provides low energy nitrogen ions which can be implanted through a hole pierced in the tip of an atomic force microscope. Ultrapure diamond samples have been implanted with spot sizes of 50nm and less. Stimulated Emission Depletion (STED) microscopy has been used to characterise and resolve the implanted spots.

2010-03-21

259

Boron-enhanced-diffusion of boron: The limiting factor for ultra-shallow junctions  

Energy Technology Data Exchange (ETDEWEB)

Reducing implant energy is an effective way to eliminate transient enhanced diffusion (TED) due to excess interstitials from the implant. It is shown that TED from a fixed Si dose implanted at energies from 0.5 to 20 keV into boron doping-superlattices decreases linearly with decreasing Si ion range, virtually disappearing at sub-keV energies. However, for sub-keV B implants diffusion remains enhanced and x{sub j} is limited to {ge} 100 nm at 1,050 C. The authors term this enhancement, which arises in the presence of B atomic concentrations at the surface of {approx} 6%, Boron-Enhanced-Diffusion (BED).

1997-12-01

261

#left brace#311#right brace# Defects in ion-implanted silicon: The cause of transient diffusion, and a mechanism for dislocation formation  

International Nuclear Information System (INIS)

Ion implantation is used at several critical stages of Si integrated circuit manufacturing. The authors show how #left brace#311#right brace# defects arising after implantation are responsible for both enhanced dopant diffusion during annealing, and stable dislocations post-anneal. They observe #left brace#311#right brace# defects in the earliest stages of an anneal. They subsequently undergo rapid Ostwald ripening and evaporation. At low implant doses evaporation dominates, and they can quantitatively relate the interstitials emitted from these defects to the transient enhancement in diffusivity of dopants such as B and P. At higher doses Ostwald ripening is significant, and they observe the defects to undergo a series of unfaulting reactions to form both Frank loops and perfect dislocations. They demonstrate the ability to control both diffusion and dislocations by the addition of small amounts of carbon impurities.

1995-03-20

262

Study of silicon damage caused by ultra-low energy boron implantation  

International Nuclear Information System (INIS)

Ultra-shallow junction formation in deep submicron Si devices is limited by anomalous diffusion of the dopant, which is related to the release of interstitials from defect clusters formed during the implantation of energetic ions or the subsequent annealing. The work described in this dissertation is concerned with the effects of low energy B ion implantation, especially damage formation, clustering and its annealing. After a review of the stopping and ranges of energetic ions in Si, the formation of implant damage, in particular of point defects, their migration, agglomeration and annihilation, including the involvement of dopant ions, is considered. A description of the Salford ultra low energy implanter is given and the main analysis technique, medium ion energy scattering (MEIS) reviewed. Additional analytical techniques used, such as secondary ion mass spectrometry (SIMS), 4-point probe and cross ...

263

Transient enhanced diffusion from decaborane molecular ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion (TED) from implantation of 5thinspkeVthinspB{sub 10}H{sub 14} and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10{sup 14} and 10{sup 15}thinspcm{sup {minus}2}. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10{sup 15}thinspcm{sup {minus}2}thinspB dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by ...

1998-10-01

264

Transient enhanced diffusion from decaborane molecular ion implantation  

International Nuclear Information System (INIS)

Transient enhanced diffusion (TED) from implantation of 5keVB_1_0H_1_4 and 0.5 keV B ions has been quantified and compared for nominal boron doses of 10"1"4 and 10"1"5cm"-"2. Boron diffusivity during annealing was extracted from secondary ion mass spectroscopy depth profiles of diffused marker layers in boron doping-superlattices and the actual implanted B dose was independently measured by nuclear reaction analysis. Comparable enhancements were observed from both ions. Transmission electron microscopy analysis revealed that both boron- and decaborane-implanted samples were amorphized at a nominal 10"1"5cm"-"2B dose. A comparison with data from low energy Si implants revealed a similar dependence of diffusivity enhancement on implant dose. These findings are consistent with the understanding that TED is caused by the interstitial supersaturation resulting from a number of excess ...

1998-10-01

265

Transient enhanced diffusion and deactivation of ion-implanted As in strained Si  

International Nuclear Information System (INIS)

First results on the effects of strain on transient enhanced diffusion and deactivation of As-implanted ultrashallow junctions are presented. A significant effect of strain on the magnitude and timescale of transient enhanced diffusion is observed, which is consistent with the stabilization of interstitial-type defects by tensile strain. Our results show no significant impact of strain on As electrical activity during the deactivation timescale accessed in this study.

2005-08-01

266

The Significance of Clopidogrel Low-Responsiveness on Stent Thrombosis and Cardiac Death Assessed by the Verifynow P2Y12 Assay in Patients With Acute Coronary Syndrome Within 6 Months After Drug-Eluting Stent Implantation  

UK PubMed Central (United Kingdom)

Background and ObjectivesClopidogrel resistance or low-responsiveness may be associated with recurrent atherothrombotic events after drug-eluting stent (DES) implantation. We prospectively...Full Text Available

2009-12-01

267

Simulation of arsenic diffusion during rapid thermal annealing of silicon layers doped with low-energy high-dose ion implantation  

International Nuclear Information System (INIS)

The model of transient enhanced diffusion of ion-implanted As is formulated and the finite-difference method for numerical solution of the system of equations obtained is developed. The nonuniform distribution of point defects near the interface and more accurate description of arsenic clustering are simultaneously taken into account. Simulation of As diffusion during rapid annealing gives a reasonable agreement with the experimental data. (authors)

2005-09-01

268

Recommendations and quality control in brachytherapy; Recommandations pour le controle de qualite en curietherapie  

Energy Technology Data Exchange (ETDEWEB)

Brachytherapy consists of sealed radioactive source implantation. The diversity in the nature of radioelements, in their energy and activity requires strict implantation and utilization rules. These rules include radioactive source physical parameters check, after-loading machine and treatment planning system quality assurance and safe and reproducible dosimetric systems. Patient and medical workers information guarantee radioprotection and prevention of accidental exposures. (authors)

2002-11-01

269

Pitting and intergranular corrosion resistances of nitrogen ion implanted type 304 stainless steel  

International Nuclear Information System (INIS)

Type 304 stainless steel (SS) specimens sensitised at 873 K and 973 K for 1, 10 and 100 hours respectively were ion implanted using a 150 keV accelerator at an energy of 70 keV in two different doses of nitrogen namely 1 x 10"1"6 to 1 x 10"1"7 ions/cm"2. Ion implantation at 1 x 10"1"6 ions/cm"2 did not show any improvement in pitting resistance, however, the specimens implanted at 1 x 10"1"7 ions/cm"2 showed significant increase in pitting corrosion resistance when potentiodynamic anodic polarisation studies were carried out in acidic chloride medium. For specimens aged at 873 K, nitrogen ion implantation at 1 x 10"1"6 ions/cm"2 increased the intergranular corrosion susceptibility compared to that of unimplanted specimens. However, at the dose of 1 x 10"1"7 ions/cm"2, insignificant IGC attack was noticed. The IGC resistance increased with increase in the dose for all the specimens aged at 973 K, and the ...

1998-05-24

270

Outcome of in-the-bag implanted square-edge polymethyl methacrylate intraocular lenses with and without primary posterior capsulotomy in pediatric traumatic cataract  

UK PubMed Central (United Kingdom)

Purpose:To study the outcome of in-the-bag implanted square-edge polymethyl methacrylate (PMMA) intraocular lenses (IOL) with and without primary posterior capsulotomy in...Full Text Available

2011-09-01

271

Optical image storage in ion implanted PLZT ceramics  

International Nuclear Information System (INIS)

We have demonstrated that optical images can be stored in transparent lead-lanthanum-zirconate-titanate (PLZT) ceramics by exposure to near-UV light with photon energies greater than the band gap energy of approx. equal to 3.35 eV. The image storage process relies on optically induced changes in the switching properties of ferroelectric domains (photoferroelectric effect). Stored images are nonvolatile but can be erased by uniform UV illumination and simultaneous application of an electric field. Although high quality images, with contrast variations of >= 100:1 and spatial resolution of approx. equal to 10 #mu#m, can be stored using the photoferroelectric effect, relatively high exposure energies (approx. equal to 100 mJ/cm"2) are required to store these images. This large exposure energy severely limits the range of possible applications of nonvolatile image storage in PLZT ceramics. We have recently found from studies of H, He and Ar implanted PLZT that the ...

272

Introduction to corrosion of bioimplants  

British Library Electronic Table of Contents (United Kingdom)

The review provides a general idea about the types of metallic alloys and the pure metals used as implant materials in dental and orthopedic surgery. Their corrosive behavior in both real solutions and various media that model human biological fluids is described. Based on the literature data, it is concluded that multicomponent alloys containing titanium, niobium, zirconium, tungsten, molybdenum, aluminum, and silicon are the most resistant to corrosion. Implants made of different types of stainless steel are preferred when manufacturing orthopedic devices for short-term use.

2011-01-01

273

Boron uphill diffusion during ultrashallow junction formation  

International Nuclear Information System (INIS)

The recently observed phenomenon of boron uphill diffusion during low-temperature annealing of ultrashallow ion-implanted junctions in silicon has been investigated. It is shown that the effect is enhanced by preamorphization, and that an increase in the depth of the preamorphized layer reduces uphill diffusion in the high-concentration portion of boron profile, while increasing transient enhanced diffusion in the tail. The data demonstrate that the magnitude of the uphill diffusion effect is determined by the proximity of boron and implant damage to the silicon surface.

2003-05-26

274

A study of palladium silicide formed by focused ion beam implantation of palladium ions  

Science.gov (United States)

The formation and properties of Pd{sub 2}Si formed by focused ion beam implantation of Pd ions into Si is presented in this thesis. An extensive microstructural study using transmission electron microscopy was undertaken and the as-implanted as well as annealed microstructure is shown. Results of other analysis techniques such as Rutherford back scattering and secondary ion mass spectrometry etc. are also presented. Kinetic information on the growth of Pd{sub 2}Si obtained by both microstructural and resistance measurements indicates that the activation energy for growth of the silicide is around 0.36 to 0.39 eV. This can be compared with the normally reported value of 1.5 eV for Pd{sub 2}Si formed by annealing thin film Pd on Si. The growth of the silicide was found to follow t{sup 1/2} kinetics. Microstructural observation of the as-implanted samples showed extensive in-situ formation of Pd{sub 2}Di and also surprisingly ...

1989-01-01

275

A study of palladium silicide formed by focused ion beam implantation of palladium ions  

International Nuclear Information System (INIS)

The formation and properties of Pd_2Si formed by focused ion beam implantation of Pd ions into Si is presented in this thesis. An extensive microstructural study using transmission electron microscopy was undertaken and the as-implanted as well as annealed microstructure is shown. Results of other analysis techniques such as Rutherford back scattering and secondary ion mass spectrometry etc. are also presented. Kinetic information on the growth of Pd_2Si obtained by both microstructural and resistance measurements indicates that the activation energy for growth of the silicide is around 0.36 to 0.39 eV. This can be compared with the normally reported value of 1.5 eV for Pd_2Si formed by annealing thin film Pd on Si. The growth of the silicide was found to follow t"1"/"2 kinetics. Microstructural observation of the as-implanted samples showed extensive in-situ formation of Pd_2Di and also surprisingly few defect structures. ...

276

5.6-nm p"+/n junction formation for sub-0.05-#mu#m PMOSFETs by using low-energy B_1_0H_1_4 ion implantation  

International Nuclear Information System (INIS)

Decaborane (B_1_0H_1_4) cluster ions were implanted into n-Si(100) substrates to fabricate shallow p"+/n junctions. Implant energies of 2 keV, 5 keV, and 20 keV, equivalent to implant energies of the monomer boron ion of 174 eV, 435 eV, and 1.74 keV, respectively, were used at dosages of 1 X 10"1"2 /cm"2 and 1 X 10"1"3 /cm"2. The implanted samples were then subjected to activation annealing at 800 .deg. C, 900 .deg. C, and 1000 .deg. C for 10 s. By using secondary ion mass spectrometry (SIMS) depth profiles, we determined that the depth of the shallow junction (D_s) at a dosage of 1 X 10"1"3 /cm"2 was in the range 12 nm - 45 nm after annealing at 1000 .deg. C. D_s and transient enhanced diffusion (TED) were greatly reduced at implant energies lower than 5 keV, but thermal diffusion (TD) smoothly decreased. In particular, TED was suppressed in the p"+/n junction ...

2004-06-01

277

Third order optical nonlinearity of colloidal metal nanoclusters formed by MeV ion implantation  

Energy Technology Data Exchange (ETDEWEB)

We report the results of characterization of nonlinear refractive index of the composite material produced by MeV Ag ion implantation of LiNbO{sub 3} crystal (z-cut). The material after implantation exhibited a linear optical absorption spectrum with the surface plasmon peak near 430 nm attributed to the colloidal silver nanoclusters. Heat treatment of the material at 500 C caused a shift of the absorption peak to 550 nm. The nonlinear refractive index of the sample after heat treatment was measured in the region of the absorption peak with the Z-scan technique using a tunable picosecond laser source (4.5 ps pulse width). The experimental data were compared against the reference sample made of MeV Cu implanted silica with the absorption peak in the same region. The nonlinear index of the Ag implanted LiNbO{sub 3} sample produced at five times less fluence is on average two times greater than that of the ...

1998-05-01

278

The impact of nitrogen co-implantation on boron ultra-shallow junction formation and underlying physical understanding  

International Nuclear Information System (INIS)

In this paper, we show that boron transient enhanced diffusion can be reduced to different extents by varying the distribution of nitrogen atoms in the junction. This is attributed to the relative location of nitrogen atoms with respect to boron profile and end-of-range defect band, affecting the interactions between dopants and defects upon annealing. In addition, variations in boron dopant activation and deactivation are also observed. Similar to fluorine co-implantation, it is proposed that nitrogen atoms react with vacancy point defects to form nitrogen-vacancy clusters that will trap the interstitials emitted from end-of-range defects. However, we report that the interstitial sink efficiency of nitrogen atoms is not as good as the co-implanted carbon atoms, which is noticed from the dopant deactivation curves. In terms of extended defect evolution, the results clearly indicate that end-of-range defects can be stabilized by choosing the ...

2008-12-05

279

Metallic implants and exposure to radiofrequency radiation  

International Nuclear Information System (INIS)

There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches"1. The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to ...

280

Mechanism for transient-enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

High-dose ion implantation followed by solid-phase-epitaxial (SPE) growth is now a well-established technique for the production of supersaturated silicon alloys. However, these alloys also contain a high supersaturation of silicon interstitials, which give rise to transient, greatly enhanced dopant diffusion with subsequent heating. In this contribution, the authors present a study of a series of Si-Sb alloys of various concentrations which were made by Sb implantation under various conditions to deduce the origin of the observed transient diffusion. A multiple implant scheme was employed to produce samples with an approximately uniform dopant concentration from 40 to 150 nm in depth, but with the amorphous layer extending to a depth of 380 nm. By scaling the implant doses, alloys with different concentrations in the uniform region were produced, allowing an accurate measure of diffusion coefficients ...

1985-03-01

281

Formation of high resistivity regions in [ital p]-type Al[sub 0. 5]In[sub 0. 5]P by ion implantation  

Science.gov (United States)

Ion implantation has been applied to magnesium-doped Al[sub 0.5]In[sub 0.5]P to produce high resistivity regions for the first time. Hydrogen, oxygen, and argon ions were implanted at a base dose ranging from 5[times]10[sup 12] to 5[times]10[sup 14] cm[sup [minus]2] and annealed from 400 to 900 [degree]C. Hydrogen did not appreciably compensate the In[sub 0.5]Al[sub 0.5]P layer while oxygen and argon produced sheet resistances up to 1[times]10[sup 9] [Omega]/[open square]. After annealing at 800 [degree]C, regions with high dose oxygen implants maintained a sheet resistance above 1[times]10[sup 7] [Omega]/[open square], while regions with high dose argon implants recovered most of the unimplanted conductivity.

1993-12-06

282

Experimental studies on reconstruction of peripheral arteries by high voltage cathode ray irradiated allografts  

International Nuclear Information System (INIS)

The use of cathode ray irradiated arterial allografts on the reconstruction of small peripheral arteries is described. The fate of irradiated arterial allografts implanted subcutaneously in rats was compared histologically with that of allografts which were fresh, frozen or stored in 70% alcohol. Follow-up studies were made of 10 dogs in which irradiated arterial allografts had been implanted in the femoral artery to be evaluated; long term patency by arteriography, gross and histologic changes of the implanted allografts, and the luminal surface of the implanted allografts by scanning electron microscopic studies. For the purpose of antigenic studies, extracts of canine arteries which had been irradiated, frozen or stored in 70% alcohol, were prepared and tested by the following immunological methods: precipitation, Ouchterlony gel diffusion, and passive cutaneous anaphylaxis. From the results obtained ...

1976-01-01

283

Effect of silicon ion implantation upon the structure and corrosion resistance of the surface layer of stainless steel 316L, Vitalium and titanium alloy Ti6Al14V  

International Nuclear Information System (INIS)

Samples of 316L stainless steel, Vitalium and Ti6A14V titanium alloy have been implanted with doses of 1.5, 3, and 4.5 x 10"1"7 Si"+/cm"2. Transmission electron microscopy shows that during ion implantation amorphous layers are formed. When samples of titanium alloy were implanted with a dose of 0.5 x 10"1"7 Si"+/cm"2, the implanted layer consisted of a dispersion of fine silicide crystallites instead of being amorphous. The corrosion resistance was analyzed by electrochemical techniques in 0.9% NaCl at the temperature of 37 C. The increase of corrosion resistance has been observed as a result of structural modifications of the surface layer. (author). 7 refs, 4 tabs.

284

Dependence of anomalous phosphorus diffusion in silicon on depth position of defects created by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion of phosphorus in silicon has been investigated for implants below and above the threshold for a complete amorphization. Rapid thermal processes (electron beam) and conventional furnaces have been used for the annealing. In the case of implants below amorphization, a strong enhanced diffusion, proportional to the amount of damage produced, has been observed. The extent of the phenomenon is practically independent of the damage depth position. In contrast to this, the formation of extended defects at the original amorphous-crystalline interface makes the diffusivity strongly dependent on depth in the case of post-amorphized samples. No enhanced diffusion effect is observed if the dopant is confined in the amorphous layer, while a remarkable increase in the diffusivity is detected for the dopant located in the crystalline region beyond the amorphous-crystalline interface. Damage distribution after ...

1989-03-01

285

Comparative study of the osseointegration of dental implants after different bone augmentation techniques: vascularized femur flap, non-vascularized femur graft and mandibular bone graft  

British Library Electronic Table of Contents (United Kingdom)

Abstract Objectives: The purpose of this study was to evaluate the osseointegration of the dental implants placed into the mandible augmented with different techniques in pigs. Material and methods: Four adult domestic pigs were used. Horizontal augmentation of the mandible was performed in animals by using vascularized femur flap (VFF), non-vascularized femur graft (NVFG) and monocortical mandibular block graft (MG). After 5 months of healing 10 dental implants were placed into each augmented site. The pigs were sacrificed after 3 months of healing. Undecalcified sections were prepared for histomorphometric analysis. Results: Mean bone-implant contact (BIC) values for implants placed into MG, NVFG and VFF were 57.38 11.97%, 76.5 7.88%, 76.53 8.15%, respectively. The BIC values of NVFG and...

2011-01-01

286

Atomistic modeling of the effects of dose and implant temperature on dopant diffusion and amorphization in Si  

International Nuclear Information System (INIS)

We discuss atomistic simulations of ion implantation and annealing of Si over a wide range of ion dose and substrate temperatures. The DADOS Monte Carlo model has been extended to include the formation of amorphous regions, and this allows simulations of dopant diffusion at high doses. As the dose of ions increases, the amorphous regions formed by cascades eventually overlap, and a continuous amorphous layer is formed. In that case, most of the excess interstitials generated by the implantation are swept to the surface as the amorphous layer regrows, and do not diffuse in the crystalline region. This process reduces the amount of transient enhanced diffusion (TED) during annealing. This model also reproduces the dynamic annealing during high temperature implants. In this case, the local amorphous regions regrow as the implant proceeds, without the formation of a continuous amorphous layer. For ...

2001-06-01

287

A study of corrosion resistance behavior for W + C dual implanted H13 steel  

International Nuclear Information System (INIS)

The surface layer optimized in resistance of corrosion and wear has been obtained by W + C dual implantation on H13 steel. The electrochemical polarization measurements show that the peak current density I_D is increased and then saturated with increasing of voltage scanning loops. The I_D is 100 times smaller than that of H13 steel, and 2-3 times smaller than that of tungsten. Then influence of dual implantation order on corrosion resistance is also studied. The I_D for W_5C_8 implanted first with W is half of that for C_5W_5 implanted first with C. The corrosion resistance structure of the samples after corrosion is observed by SEM. The X-ray analysis indicates that the structure consists of disperse phases of WC, W_2C, FeW, Fe_2W, FeW_2C and iron carbides. It is shown from Auger analysis that the optimum complex layer for corrosion resistance consists of thin carbon film on surface, disperse phases ...

288

A kinetic Monte Carlo annealing assessment of the dominant features from ion implant simulations  

International Nuclear Information System (INIS)

Ion implantation and subsequent annealing are essential stages in today's advanced CMOS processing. Although the dopant implanted profile can be accurately predicted by analytical fits calibrated with SIMS profiles, the damage has to be estimated with a binary collision approximation implant simulator. Some models have been proposed, like the '+n', in an attempt to simplify the anneal simulation. We have used the atomistic kinetic Monte Carlo dados to elucidate which are the implant modeling features most relevant in the simulation of transient enhanced diffusion (TED). For the experimental conditions studied we find that the spatial correlation of the I, V Frenkel pairs is not critical in order to yield the correct I supersaturation, that can be simulated just taking into account the net I-V excess distribution. In contrast to, simulate impurity clustering/deactivation when there is an impurity ...

2004-12-15

289

Yakima River Species Interactions Studies, Annual Report 1999.  

Energy Technology Data Exchange (ETDEWEB)

Species interactions research and monitoring was initiated in 1989 to investigate ecological interactions among fish in response to proposed supplementation of salmon and steelhead in the upper Yakima River basin. This is the eighth of a series of progress reports that address species interactions research and pre-supplementation monitoring of fishes in the Yakima River basin. Data have been collected prior to supplementation to characterize the ecology and demographics of non-target taxa (NTT) and target taxon, and develop methods to monitor interactions and supplementation success. Major topics of this report are associated with implementing NTT monitoring prescriptions for detecting potential impacts of hatchery supplementation, hatchery fish interactions, and monitoring fish predation indices. This report is organized into four chapters, with a general introduction preceding the first chapter. This annual report summarizes data collected primarily by the ...

2001-06-01

290

White River Falls Fish Passage Project, Tygh Valley, Oregon : Final Technical Report, Volume III, Appendix B, Fisheries Report; Appendix C, Engineering Alternative Evaluation; Appendix D, Benefit/Cost Analysis.  

Energy Technology Data Exchange (ETDEWEB)

Studies were conducted to describe current habitat conditions in the White River basin above White River Falls and to evaluate the potential to produce anadromous fish. An inventory of spawning and rearing habitats, irrigation diversions, and enhancement opportunities for anadromous fish in the White River drainage was conducted. Survival of juvenile fish at White River Falls was estimated by releasing juvenile chinook and steelhead above the falls during high and low flow periods and recapturing them below the falls in 1983 and 1984. Four alternatives to provide upstream passage for adult salmon and steelhead were developd to a predesign level. The cost of adult passage and the estimated run size of anadromous fish were used to determine the benefit/cost of the preferred alternative. Possible effects of the introduction of anadromous fish on resident fish and on nearby Oak Springs Hatchery were evaluated. This included an inventory of resident species, a genetic ...

1985-06-01

291

Summary Report for Bureau of Fisheries Stream Habitat Surveys: Cowlitz River Basin, 1934-1942 Final Report.  

Energy Technology Data Exchange (ETDEWEB)

This document contains summary reports of stream habitat surveys, conducted in the Cowlitz River basin, by the Bureau of Fisheries (BOF, now National Marine Fisheries Service) from 1938-1942. These surveys were part of a larger project to survey streams in the Columbia River basin that provided, or had provided, spawning and rearing habitat for salmon and steelhead. The purpose of the survey was, as described by Rich, [open quotes]to determine the present condition of the various tributaries with respect to their availability and usefulness for the migration, breeding, and rearing of migratory fishes[close quotes]. Current estimates of the loss of anadromous fish habitat in the Columbia River Basin are based on a series of reports published from 1949-1952 by the U.S. Fish and Wildlife Service. The reports were brief, qualitative accounts of over 5000 miles of stream surveys conducted by the BOF from 1934-1946. Despite their brevity, these BOF reports have formed ...

1995-01-01

292

Metal leaching and acid mine drainage in British Columbia; La lixiviation des metaux et le drainage acide en Colombie-Britannique  

Energy Technology Data Exchange (ETDEWEB)

This poster presentation dealt with a brief overview of the practices in effect in British Columbia related to metal leaching and acid mine drainage. The metals mined in the province include coal, gold, silver, copper, molybdenum, lead, and zinc. Some mines operate under the surface, while others are strip mines, etc. under a variety of climactic conditions and a host of different mining companies, such as Cominco, Placer Dome and Noranda. The primary objective is the prevention of negative environmental impacts on land and in the water. Salmon and other fish need to be protected. A secondary objective is the minimization of impacts on the biota, which requires a detailed study of ecological risks. The solution often lies in soil covering. To illustrate, the author described the situation at Huckleberry Mines Ltd. and the remedial action that was implemented, and discussed the results on the beavers. In conclusion, the author discussed the strategies implemented by ...

2000-07-01

293

Columbia River Coordinated Information System (CIS); Phase II Cooperative Agreement, 1992 Technical Report.  

Energy Technology Data Exchange (ETDEWEB)

Anadromous salmon in the Columbia River Basin are presently far below historic level of production, due to the impacts of development in the basin. To halt the downward trend in production and ultimately increase returns, the Northwest Power Planning Council developed the Columbia River Basin Fish and Wildlife Program. The Program outlines a coordinated plan for restoring anadromous salmonid runs to the basin. The goals and objectives outlined in the Program require addressing a complex set of problems that encompass a broad range of social, political, economic and biological issues. Resolution of these problems will require the efforts of a number of federal, state, and tribal agencies that have regulatory authority over activities that either directly or indirectly affect anadromous salmonids in the basin. Resource managers have realized the need for coordination in these efforts. The Coordinated Information System is designed to share information critical to ...

1993-05-01

294

Usefulness of Computed Tomography in pre-surgical evaluation of maxillo-facial pathology with rapid prototyping and surgical pre-planning by virtual reality  

International Nuclear Information System (INIS)

Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been preformed on 12 patients ...

2005-11-01

295

The role of surgical margins in treatment of Ewing's sarcoma family tumors: Experience of a single institution with 512 patients treated with adjuvant and neoadjuvant chemotherapy  

International Nuclear Information System (INIS)

Purpose: To evaluate the importance of surgical margins for local and systemic control of Ewing's sarcoma family tumors (ESFT). Methods and Materials: Between 1979 and 1999, 512 patients with ESFTs entered 4 different adjuvant and neoadjuvant studies performed at a single institution. Of these patients, 335 were treated with surgery alone (196) or surgery followed by radiotherapy at doses of 44.8 Gy (139). We compared their outcome with that of the 177 patients who were locally treated by radiotherapy at 60 Gy. Results: Local control (88.8% vs. 80.2%, p < 0.009) and 5-year disease-free survival (63.8% vs. 47.6%, p < 0.0007) were significantly better in patients treated with surgery and, among them, in those with adequate surgical margins (96.6% vs. 71,7%, p < 0.0008, and 69.6% vs. 46.3%, p < 0.0002). Nonetheless, better results were observed only in extremity tumors. Conclusions: Surgery is better than radiotherapy in cases of ...

2006-07-01

296

Fecal incontinence in operated cases for anorectal malformations  

International Nuclear Information System (INIS)

In spite of great progress in surgical treatment of anorectal malformations, fecal incontinence is still, in variable degrees, a frequent and unpleasant postsurgical sequela. The most frequent causes of incontinence are: 1) the incorrect placement of the pulled-through colon in the levator ani and sphincteric muscular complex during abdomino-perineal surgical procedures; 2) the poor development of sphinteric musculature; 3) the associated sacral anomalies. Postoperative CT helps to evaluate all the above-mentioned conditions, in view of possible new surgical procedure for improving continence (besides postoperative CT can help in choosing the more suitable surgical technique). Nine patients, aged 3 to 13 years (2 with good continence and 7 with various degrees of incontinence), were studied with pelvic postoperative CT. In the cases (2) with good continence the CT picture was: good development of ...

1989-01-01

297

Ultra shallow P+/N junctions using plasma immersion ion implantation and laser annealing for sub 0.1#mu#m CMOS devices  

International Nuclear Information System (INIS)

Classical beam line ion implantation is limited to low energies and cannot achieve P+/N junctions requested for <45nm ITRS node. RTA (rapid thermal annealing) needs to be improved for dopants activation and damage reductions. Spike annealing process also induces a large diffusion mainly due to TED (transient enhanced diffusion). Compared to conventional beam line ion implantation limited to a minimum energy implantation of 200eV, plasma immersion ion implantation (PIII) is an emerging technique to get ultimate shallow profiles (as-implanted) due to no lower limitation of energy and high dose rate. On the another hand, laser thermal processing (LTP) allows to obtain very shallow junction with no TED, abrupt profile and activated depth control. In this paper, we show the implementation of the BF_3 PIII associated with the LTP. Ions from BF_3"+ plasma have been ...

2005-08-01

298

The effects of cosmic radiation on implantable medical devices  

Energy Technology Data Exchange (ETDEWEB)

Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A ...

1996-12-31

299

Impurity and clustering effects on defect evolution in ion-implanted Si  

Energy Technology Data Exchange (ETDEWEB)

A detailed investigation of the damage formation and evolution in ion-implanted crystalline Si is presented. Deep-level transient spectroscopy has been used to monitor room temperature migration of point defect complexes and evolution from simple point-like defect complexes to defect clusters and even extended defects. Si samples were implanted with Si or He ions with energies of 145 keV-3MeV, to fluences in the range 5x10[sup 8]-5x10[sup 13]cm[sup -2]. The effects of thermal annealing, in the range 100-680 C and 10 min-15h, were also explored. A systematic comparison of defect complexes formation and evolution in ion-implanted or electron-irradiated Si samples with a different impurity content were used to assess the role of impurities (C and O), extra implanted ion and defect clustering on the nature and thermal stability of residual damage. In particular, an interstitial excess directly resulting ...

1998-10-01

300

Effects of mesh-assisted carbon plasma immersion ion implantation on the surface properties of insulating silicon carbide ceramics  

International Nuclear Information System (INIS)

Plasma immersion ion implantation (PIII) is an effective materials modification and synthesis technique but has seldom been applied to ceramic materials due to the high electrical resistance that reduces the ion bombardment energy and sometimes causes serious electrical arcing in the instrument. Even in cases where PIII is applicable, the surface properties of the implanted insulating materials can be seriously affected due to the low ion energy and materials damage from electrical arcing. In order to enhance the surface and mechanical properties such as wear resistance of ceramic materials used in many industrial applications, surface modification is needed. In this work, we conduct carbon implantation into sintered #alpha#-SiC (silicon carbides that are widely used in vacuum ceramic bearings) using mesh-assisted plasma immersion ion implantation to enhance the surface properties. The use of a ...

2004-03-01

301

The use of biodegradable polylactic acid barrier materials in the treatment of grade II periodontal furcation defects in humans--Part II: A multicenter investigative surgical study.  

Science.gov (United States)

This study evaluated whether differences in design of 3-dimensional polylactic acid barriers (EPi-Guide and Guidor) would influence hard tissue results in the treatment of Grade II furcations in humans. A multicenter study was conducted, using 40 patients with moderate to advanced bilateral chronic adult periodontitis of the mandibular first or second molars. After flap access, debridement, and root preparation, surgical bone level measurements were taken and membranes were placed on a random basis. Surgical reentry occurred at 1 year. Data collected from all 3 investigative centers were pooled and analyzed using an analysis of variance appropriate for a counterbalancing design. Both barrier materials resulted in significant gains of attachment level and defect reduction. The composite reduction in the vertical component of the osseous defects was greater in the sites treated with Epi-Guide as compared to those treated with Guidor; the ...

1999-02-01

302

Radionuclear estimation with {sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy of recurrent hepatocellular carcinoma after non-surgical treatment  

Energy Technology Data Exchange (ETDEWEB)

{sup 99m}Tc-N-pyridoxyl-5-methyl-tryptophan (PMT) scintigraphy, which exhibits highly specific for the diagnosis of primary hepatocellular carcinoma (HCC), was performed for recurrent HCC following non-surgical treatment. Eighty-four patients (total 351 examinations) were selected for the study. The ability of PMT scintigraphy to diagnose recurrent HCC after treatment was compared with that of computed tomography, ultrasonography and angiography. The results showed that sixty-three (75%) of 84 cases demonstrated positive findings during our follow-up period, most of the tumors initially showing positive findings remained PMT positive when they recurred and PMT studies shortly after treatment demonstrated wider tracer uptake rather than the actual tumor area. In conclusion, PMT scintigraphy for patients with HCC after non-surgical treatment exhibited high accuracy in identifying viable HCC only for tumors indicating positive findings. (author)

1997-10-01

303

Localization of islet cell tumors by dynamic CT: comparison with plain CT, arteriography, sonography, and venous sampling  

Energy Technology Data Exchange (ETDEWEB)

Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level localized the pathology in the transverse plane and greatly aided in ...

1984-09-01

304

Ultrashallow P{sup +}/N junction formation by plasma ion implantation  

Energy Technology Data Exchange (ETDEWEB)

We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B{sub 2}H{sub 6} plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B{sub 2}H{sub 6} plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for ...

2000-12-01

305

Ultrashallow P"+/N junction formation by plasma ion implantation  

International Nuclear Information System (INIS)

We investigated the electrical characteristics and the junction depth of ultra-shallow junctions formed by using the plasma-doping method. Compared with ultra-low energy boron-ion implantation at 500 eV, the junctions formed with the plasma-doping process exhibited shallow junction depths and low sheet resistances. The junction depths of the plasma-doped samples were 150 A and 330 A after annealing for 10 s at 900 .deg. C and 950 .deg. C, respectively. For the same junction depth, the sheet resistance of the B_2H_6 plasma-doped sample was an order of magnitude less than that of the 500-eV B-ion implanted sample. Cross-sectional transmission electron microscopy and deep level transient spectroscopy showed that the defects formed by the B_2H_6 plasma-doping process could be removed by annealing at 950 .deg. C for 10 s. The scaling of metal-oxide-semiconductor field-effect-transistor (MOSFET) device channel lengths for high-speed application ...

2000-12-01

306

Vacancy engineering by optimized laser irradiation in boron-implanted, preamorphized silicon substrate  

International Nuclear Information System (INIS)

In this letter, the effect of vacancies generated by preirradiated laser on dopant diffusion and activation in preamorphized silicon substrate has been studied. Laser-induced melting in silicon was used to generate excess vacancies near the maximum melt depth before silicon substrate amorphization and subsequent boron implantation. We demonstrate that by matching the preirradiated laser melt depth with the implant amorphize depth, it can effectively reduce the silicon self-interstitials released from the end-of-range defect band. The results show great suppression in boron transient enhanced diffusion and significant removal of end-of-range defects. This is attributed to the recombination of laser-generated excess vacancies with preamorphizing induced free silicon interstitials at the end-of-range region.

2008-05-19

307

Transient enhanced diffusion in B/sup +/ and P/sup +/ implanted silicon  

International Nuclear Information System (INIS)

The authors report the transient enhanced diffusion of supersaturated phosphorous in ion-implanted SPE grown Si. Precipitation proceeds rapidly to a metastable SiP phase, which can be converted to an orthorhombic form or re-dissolved by subsequent heat treatment. The effects are strongly temperature dependent, and consistent with the trapped interstitial model. The behavior of different dopants follow their relative interstitialcy diffusion coefficients. The results suggest that ion implantation induced point defects dominate over thermally activated point defects during low temperature and certain rapid thermal processing, controlling dopant deactiviation and diffusion in crystalline or amorphous silicon, and can also affect the SPE growth rate.

308

The fraction of substitutional boron in silicon during ion implantation and thermal annealing  

Energy Technology Data Exchange (ETDEWEB)

We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from {ital ab initio} calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800{degree}C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. {copyright} {ital 1998 American Institute of Physics.}

1998-05-01

309

The fraction of substitutional boron in silicon during ion implantation and thermal annealing  

International Nuclear Information System (INIS)

We present results from a kinetic Monte Carlo simulation of boron transient enhanced diffusion (TED) in silicon. Our approach avoids the use of phenomenological fits to experimental data by using a complete and self-consistent set of values for defect and dopant energetics derived mostly from ab initio calculations. The results predict that, during annealing of 40 keV B-implanted Si at 800 degree C, there exists a time window during which all the implanted boron atoms are substitutional. At earlier or later times, the interactions between free silicon self-interstitials and boron atoms drive the growth of boron clusters and result in an inactive boron fraction. The results show that the majority of boron TED takes place during the growth period of interstitial clusters and not during their dissolution. copyright 1998 American Institute of Physics.

1998-05-01

310

Study of point defect detectors in Si  

International Nuclear Information System (INIS)

The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well

1999-05-01

311

Redistribution of implanted dopants after metal-silicide formation  

Science.gov (United States)

The redistribution of implanted As and Sb following metal-silicide formation of Pt, Pd, and Ni has been studied. The phases of the silicides used were PtSi, Pd/sub 2/Si, and NiSi. Investigations with Rutherford backscattering analysis showed that after the formation of the silicides, the Sb was always found in the silicide layer near the surface of the samples, whereas PtSi and Pd/sub 2/Si caused a partial rejection of As for implanted doses of 2 x 10/sup 15/ cm/sup -2/ and higher. No rejection of As was found after the formation of NiSi. The results are discussed in terms of solid solubilities and impurity-metal compound formation. The data presented has implications in the fabrication of Ohmic contacts and the adjustments of the heights of Schottky barriers on silicon.

1978-12-01

312

Redistribution of implanted dopants after metal-silicide formation  

International Nuclear Information System (INIS)

The redistribution of implanted As and Sb following metal-silicide formation of Pt, Pd, and Ni has been studied. The phases of the silicides used were PtSi, Pd_2Si, and NiSi. Investigations with Rutherford backscattering analysis showed that after the formation of the silicides, the Sb was always found in the silicide layer near the surface of the samples, whereas PtSi and Pd_2Si caused a partial rejection of As for implanted doses of 2 x 10"1"5 cm"-"2 and higher. No rejection of As was found after the formation of NiSi. The results are discussed in terms of solid solubilities and impurity-metal compound formation. The data presented has implications in the fabrication of Ohmic contacts and the adjustments of the heights of Schottky barriers on silicon.

313

Prediction of transient-enhanced diffusion during rapid thermal annealing of ion-implanted silicon  

International Nuclear Information System (INIS)

There have been several reports of transient-enhanced diffusion during furnace or rapid thermal annealing of ion-implanted silicon and some reports of no enhancement. In this contribution, the authors show that many of the observed effects can be accounted for by an interstitial trapping mechanism, in which large numbers of Si atoms are trapped by group V dopant atoms in the amorphous material during implantation. These trapped atoms are retained during solid-phase-epitaxial (SPE) growth, but can be released later during thermal processing to give the transient-enhanced diffusion. The authors present a model which can predict the transient effects (or lack of them) for any concentration of Sb, Bi, or As dopants sufficient to amorphize the silicon and any thermal processing technology which relies on SPE growth (furnace, cw laser, or rapid thermal annealing).

1985-03-01

314

Microstructure, mechanical properties and fracture behavior of #alpha# particle irradiated type 316 stainless steel  

International Nuclear Information System (INIS)

The present work is a research of the effect of helium on the microstructure, mechanical properties and fracture behaviors of a type 316 austenitic steel. Helium implantation was performed by 30-MeV #alpha#-particle injection on very small size specimens, using a cyclotron. Average helium content in a He-deposited region was up to 2000 appm He. In the case of 2000appm He implantation, intergranular fracture was sometimes observed on the helium deposited region after tensile test at room temperature. At elevated temperature test, however, this material showed the transition of fracture mode from transgranular-ductile fracture at 773K to intergranular fracture at 873. In the case of 500 appm He implantation, the transition of fracture mode was recognized at a temperature range of 873K to 973K. (author).

315

Mechanical properties and fracture behavior of #alpha# particle irradiated type 316 stainless steel at high temperature  

International Nuclear Information System (INIS)

The effect of helium on the mechanical properties and fracture behaviors of a type 316 austenitic steel is presented. Helium implantation was performed by 30-MeV #alpha#-particle injection on very small, thin specimens, using a cyclotron accelerator. Average helium content in the He-deposited region was 50 to 2000 appm He. These specimens showed the transition of fracture mode from transgranular to intergranular fracture in elevated temperature tests. The transition temperature decreased with increase in the amount of implanted helium. For example, in the case of 2000 appm and 500 appm He implantation, the transition temperatures were between 773 and 873 K and 873 and 973 K, respectively. (orig.).

316

Long-term changes in graft height after maxillary sinus floor elevation with different grafting materials: radiographic evaluation with a minimum follow-up of 4.5 years  

British Library Electronic Table of Contents (United Kingdom)

Abstract Objective: To compare the vertical dimensional changes with regard to graft height in a long-term follow-up in patients treated with two different grafting materials used in maxillary sinus floor elevation procedures. Material and methods: Twenty consecutive patients were included. One group was grafted with autogenous bone from the mandible (chin area), and the other group was augmented with a 100%b-tricalcium phosphate (b-TCP). During a 4- to 5-year period, in each patient, at least five panoramic radiographs were made. These panoramic radiographs were used for morphometric measurements, at three different locations. The three locations were the first bone to implant contact at the distal side of the second most posterior implant (L1), halfway between this implant and the most p...

2009-01-01

317

Intestinal Ischemia for estenosis of the superior mesenteric artery, Treatment with angioplastia and stent implant  

International Nuclear Information System (INIS)

Chronic mesenteric arterial ischemia is an uncommon condition associated a high morbidity and mortality. It is most Commonly caused by atherosclerotic occlusive disease. Patients may suffer epigastric or periumbilical postprandial pain ten to thirty minutes after eating. A case of chronic mesenteric artery stenosis, the diagnosis was performance with colonoscopy and biopsy. We present a case report of a patient with chronic mesenteric ischemia. Mesenteric arteriography was performed and documented estenosis of the mesenteric superior artery. Then percutaneous arteriography with angioplasty and implant of stent was performed. The patients became completely asymptomatic and normal colon mucous is observed in control colonoscopy. The purpose of this report is to present the case endoscopy, clinic and radiological features and to describe the percutaneous angioplasty and implant of stent. We believe that angioplasty treatment offers and improvement ...

318

Influence of fluorine on the simulation of the transient enhanced diffusion of 15 keV BF_2"+ ion implantation into silicon  

International Nuclear Information System (INIS)

We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF_2"+) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF_2"+ implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.

2002-01-01

319

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

320

Effect of zinc and its form of supply on production and quality of coffee beans  

British Library Electronic Table of Contents (United Kingdom)

Abstract BACKGROUND: In Brazil, the usual forms of zinc (Zn) supply to coffee plants have limitations that compromise the element availability to the plant. This study proposes to test an alternative approach to supplying the nutrient to Coffea arabica L. using trunk implanted zinc tablets. Additionally, the effect of Zn on the production and quality of coffee beans was also evaluated. RESULTS: The highest total coffee bean production was recorded in plants implanted with Zn tablets (TA), while the lowest was recorded in the control treatment, without zinc supply (WZn), reaching a bianual production of 188.2 and 130.1 60-kg bags of processed beans per hectare, respectively. In the treatments where Zn were applied as tablet implantation or as foliage spraying (SZn); the bean size was larger...

2011-01-01

321

Characterization of polysilicon thin-film transistors with asymmetric source/drain implantation  

Energy Technology Data Exchange (ETDEWEB)

The effect of asymmetry tilt angle ion implantation on polysilicon thin-film transistors (TFTs) device characteristics are investigated. This asymmetric source/drain (S/D) TFTs structure exhibits low leakage current and suppressed kink effect due to the relief of higher electric field near the drain junction side. It is shown that the optimal implantation tilt angle is 30 deg. in our annealing condition. And the anomalous off-state current is more than two orders of magnitude lower than that of the conventional TFTs. By well controlled the LDD region, this structure can act as a conventional structure in the on-state and the turn-on current will not be degraded. Besides, the device under severe hot carrier bias stress shows better hot carrier endurance.

2005-08-01

322

Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten  

Energy Technology Data Exchange (ETDEWEB)

On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

1990-09-01

323

Atomic scale models of Ion implantation and dopant diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

We review our recent work on an atomistic approach to the development of predictive process simulation tools. First principles methods, molecular dynamics simulations, and experimental results are used to construct a database of defect and dopant energetics in Si. This is used as input for kinetic Monte Carlo simulations. C and B trapping of the Si self- interstitial is shown to help explain the enormous disparity in its measured diffusivity. Excellent agreement is found between experiments and simulations of transient enhanced diffusion following 20-80 keV B implants into Si, and with those of 50 keV Si implants into complex B-doped structures. Our simulations predict novel behavior of the time evolution of the electrically active B fraction during annealing.

1999-03-01

324

Anti-Infection Dip Suggestions for the Coloplast Titan Inflatable Penile Prosthesis in the Era of the Infection Retardant Coated Implant  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction.- Infection is the worst complication seen with inflatable penile prosthesis (IPP). Both the American Medical Systems (AMS) and Coloplast IPP have infection retardant coatings. AMS is coated at the factory with rifampicin and minocycline (InhibiZone). The Coloplast IPP has a hydrophilic coating covalently bonded to its components that will absorb any aqueous solution before implantation and provides increased surface lubricity to decrease bacterial adherence. Aim.- We tested several antibiotic dips comparing zones of inhibition (ZOI) against five commonly infecting bacteria with coated Coloplast implants. Results were compared with those ZOI created with strips of an AMS IPP precoated with InhibiZone. Methods.- Pieces of sterile Coloplast Titan IPP were dipped in (i) ...

2011-01-01

325

Surgical management of osteoradionecrosis of the temporal bone  

Energy Technology Data Exchange (ETDEWEB)

The surgical management of osteoradionecrosis of the temporal bone has met with limited success because of the difficulty in accurate assessment of the viability of nonnecrotic bone intraoperatively. Failure to resect all nonviable bone results in recurrence of a necrotic focus. With the use of hyperbaric oxygen therapy to stabilize marginal bone and oral tetracycline to label viable bone preoperatively, removal of all nonviable bone can be accomplished. Postoperatively, a second course of hyperbaric therapy enhances wound healing, thus assuring a successful outcome. This article details a successful systematic approach that was developed to resect a necrotic focus in the temporal bone of a 10-year-old boy who had undergone a full course of radiotherapy for treatment of a rhabdomyosarcoma.

1988-03-01

326

Surgical aspects of intestinal injury due to pelvic radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is suggested.

1985-04-01

327

Single Setting Bilateral Laparoscopic Orchiopexy for Bilateral Intra-Abdominal Testicles  

British Library Electronic Table of Contents (United Kingdom)

Purpose The laparoscopic surgical approach to unilateral intra-abdominal testis has replaced the open approach at several large centers. There is considerable literature on experience with unilateral intra-abdominal testes but little on the management of bilateral intra-abdominal testes. We assessed the feasibility and safety of performing single setting bilateral laparoscopic orchiopexy in boys with bilateral intra-abdominal testes. Materials and Methods A single surgeon experience was reviewed. The surgical technique was similar in all cases and on each side, including infra-umbilical access, diagnostic evaluation, peritoneal mobilization lateral to the spermatic vessels and inferior to the vas deferens, gubernacular transection, and a decision for or against a Fowler-Stephens procedure ...

2008-01-01

328

Reduction in incidence of deep sternal wound infections: Random or real?  

British Library Electronic Table of Contents (United Kingdom)

Objective Comorbidities predisposing cardiac surgical patients toward deep sternal wound infection, such as diabetes and obesity, are rising in the United States. Longitudinal analysis of risk factors, morbidity, and mortality was performed to assessed effects of these health trends on deep sternal wound infection rates. Methods In this retrospective analysis of all median sternotomies performed at a single institution from 1991 through 2006, demographic and surgical characteristics were identified from a prospective database. The cohort was separated into periods from 1992 through 2001 and 2002 through 2006 to identify longitudinal trends in risk factors for deep sternal wound infection. Univariate and matched multivariable analyses were performed. Results Overall, study population had in...

2010-01-01

329

Prevention of death from ingested ruthenium-106 by colectomy  

International Nuclear Information System (INIS)

Two dogs were given 3.0 mCi/kg body weight of "1"0"6Ru-"1"0"6Rh and two were given 4.0 mCi/kg. At 5 days after treatment, one dog from each dose level was colectomized. The dog given the larger dose but not surgically treated was killed in extremis due to acute lower bowel injury at 18 days. The other dog, given 3.0 mCi/kg but not surgically treated, was killed in a moribund condition at 145 days after dosing. The rectum had perforated. The colectomized dogs recovered from intestinal injury and showed no radiation damage at the termination of the study.

1977-05-01

330

Percutaneous nephrolithotomy for staghorn kidney stones in elderly patients  

British Library Electronic Table of Contents (United Kingdom)

Purpose We retrospectively analyzed the results of percutaneous nephrolithotomy operations for treatment of staghorn kidney stone disease in elderly patients and compared surgical parameters and outcomes with a control group of young adult patients. Patients and method Between 2002 and 2010, 300 consecutive patients underwent percutaneous nephrolithotomy operation for treatment of staghorn kidney stone disease. Forty-five of the patients were older than 65?years and considered to be in elderly group. Thirty-seven of the patients were between the ages 18 and 36?years and considered to be the control group. Surgical parameters and outcomes were compared between groups. Results There were no significant differences between groups for stone area, operation time, difference in hemoglobin levels...

2011-01-01

331

Outcomes of extremely low risk prostate cancer following radical prostatectomy  

British Library Electronic Table of Contents (United Kingdom)

The optimal management of men with very favorable clinicopathological factors who develop biochemical recurrence (BCR) after radical prostatectomy (RP) has not been previously reported. Both local and systemic recurrences are unlikely in this cohort. This study examines their management and outcomes. Between October 2000 to March 2010, 1627 men underwent open RP by a single surgeon. In all, 448 (27.5%) met the following criteria for extremely low risk disease: preoperative PSA level <10?ng?ml?1, clinical stage T1c/T2a, Gleason score ?6, estimated cancer volume in the surgical specimen ?5% and no evidence for positive surgical margin. Undetectable PSA was defined as ?0.04?ng?ml?1. BCR was defined as PSA ?0.2?ng?ml&#...

2011-01-01

332

Outcome of peripherally inserted central venous catheters in surgical and medical neonates  

British Library Electronic Table of Contents (United Kingdom)

Background/Purpose: Peripherally inserted central venous catheters (PICCs) are commonly used for neonatal vascular access. The aim of this study was to look at PICC line complication rates and possible predictors of PICC infection in a neonatal intensive care unit. Method: This was a prospective study of 226 neonates who had PICCs on our neonatal intensive care unit between January 2006 and June 2009. Complete data was available on 218 neonates who had 294 PICC lines. Criteria for catheter-related sepsis was positive blood cultures (peripheral/central) and/or a positive catheter tip culture after removal in the presence of a clinical suspicion of line sepsis. Results: Of 218 neonates, 132 (169 lines) were medical, and 86 (125 lines) were surgical. Our PICC line infection rate was 17 infect...

2011-01-01

333

Functional MRI-compatible laparoscopic surgery training simulator  

British Library Electronic Table of Contents (United Kingdom)

Abstract During the past few years, laparoscopy has become the gold standard for some surgical procedures and its applications continue to expand. Because of multiple factors such as loss of tactile perception, two-dimensional visualization of the three-dimensional surgical field, and demanding bimanual hand-eye coordination, special training is required to achieve proficiency with laparoscopy. In this study, as the first step toward evidence-based development of strategies to improve the quality of laparoscopy training from brain activity and behavior relationships, a laparoscopy training simulator was developed for use in functional MRI. Experiments confirmed the functional MRI compatibility of the device. Representative behavioral and functional MRI results for two subjects showed the f...

2011-01-01

334

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be considered in the appropriate selection of a device. (author)

335

Determinants of postoperative visual recovery in suprasellar meningiomas  

British Library Electronic Table of Contents (United Kingdom)

Purpose Suprasellar meningiomas usually present with visual deterioration, including decreased visual acuity and/or visual field defects. Suprasellar meningiomas have a close relationship with the optic apparatus, arteries of the anterior circulation, pituitary stalk and hypothalamus, which makes safe surgical resection a challenge especially with dissection around an already compromised optic apparatus. In this report 21 patients operated on for a suprasellar meningioma over a 4-year period are reviewed. Postoperative outcome and visual recovery are evaluated, including analysis of its determinants. Methods Over a 4-year period (2002?2006), patients surgically treated for suprasellar meningiomas were included in this retrospective study. All tumors were located at the tuberculum sellae an...

2010-01-01

336

Visual and refractive outcome of one-site phacotrabeculectomy compared with temporal approach phacoemulsification  

UK PubMed Central (United Kingdom)

BackgroundWe aimed to compare visual and refractive outcome following phacoemulsification and intraocular lens implant (IOL) and combined one-site phacotrabeculectomy.MethodWe...Full Text Available

2008-09-01

337

Use of cephalometric analysis for implant placement in a patient with an edentulous maxilla with a severe Class III intermaxillary relationship.  

Science.gov (United States)

A patient with a totally edentulous maxilla and a seVere Class III intermaxillary relationship in the anterior region was treated by implants. In the mandible, there were 10 teeth between the second premolars. The inclination and width of the maxillary anterior residual bone were measured on cephalometric X-ray film obtained before treatment. The results of cephalometric analysis did not support clockwise rotation of the mandible or lingual angling of the maxillary anterior teeth by use of prosthesis to improve the Class III relationship. Ten implants were simultaneously placed in the maxilla. Then, a maxillary temporary full bridge was seated after reduction of the crown lengths of the mandibular anterior teeth. An apically positioned flap operation was performed to eliminate periodontal pockets and to obtain clinically suitable crown lengths of the mandibular anterior teeth. A noncemented, screw-retained maxillary full bridge and a ...

2004-01-01

338

Transient enhanced diffusion in ion-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

We discuss the transient-enhanced diffusion of Sb, As, P, In, Ga, and B in ion-implanted Si, where the near-surface region has been amorphized by the dopant or by a self-implantation process. With Sb, a large transient diffusion enhancement is observed proportional to dopant concentration. For Sb, As, P, and In, the enhancement follows the relative interstitialcy diffusion coefficient. We believe this behavior is caused by stable implantation-induced point defects present in the amorphous surface layer, which decay during thermal processing to release high concentrations of self-interstitials. This process occurs in competition with the solid phase epitaxial (SPE) growth process, and for high dopant concentrations can occur in the amorphous phase ahead of the crystallization front. We believe this may be the origin of the dopant redistribution which can occur during SPE growth, which sets the upper limit to the dopant ...

1987-03-01

339

Transcatheter stent implantation to treat aortic coarctation in infancy.  

UK PubMed Central (United Kingdom)

A ten week old girl who had previously undergone a palliative procedure for the hypoplastic left heart syndrome had unrelieved aortic coarctation that did not respond to standard balloon dilatation....Full Text Available

1993-01-01

340

The inhibition of staphylococcus epidermidis biofilm formation by vancomycin-modified titanium alloy and implications for the treatment of periprosthetic infection  

UK PubMed Central (United Kingdom)

Peri-prosthetic infections are notoriously difficult to treat as the biomaterial implant is ideal for bacterial adhesion and biofilm formation, resulting in decreased antibiotic sensitivity....Full Text Available

2008-12-01

341

The effect of preamorphization energy on ultrashallow junction formation following ultrahigh-temperature annealing of ion-implanted silicon  

International Nuclear Information System (INIS)

High-power arc lamp design has enabled ultrahigh-temperature (UHT) annealing as an alternative to conventional rapid thermal processing (RTP) for ultrashallow junction formation. The time duration of the UHT annealing technique is significantly reduced from those obtained through conventional RTP. This difference in time may offer the ability to maintain a highly activated ultrashallow junction without being subjected to transient enhanced diffusion (TED), which is typically observed during postimplant thermal processing. In this study, two 200-mm (100) n-type Czochralski-grown Si wafers were preamorphized with either a 48- or a 5-keV Ge"+ implant to 5x10"1"4 cm"2, and subsequently implanted with 3-keV BF_2"+ molecular ions to 6x10"1"4 cm"2. The wafers were sectioned and annealed under various conditions in order to investigate the effects of the UHT annealing technique on the resulting junction characteristics. The main point of the paper is ...

2005-02-15

342

The development of multiple probe microdialysis sampling in the stomach  

UK PubMed Central (United Kingdom)

A multiple probe approach of implanting microdialysis probes into each separate tissue layer would better represent sampling from the stomach. Presently, microdialysis sampling experiments are...Full Text Available

2008-09-10

343

The association between metal allergy, total hip arthroplasty, and revision  

UK PubMed Central (United Kingdom)

Background and purpose It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following...Full Text Available

2009-12-04

344

The Use of Particulate Bone Grafts From the Mandible for Maxillary Sinus Floor Augmentation Before Placement of Surface-Modified Implants: Results From Bone Grafting to Delivery of the Final Fixed Prosthesis  

British Library Electronic Table of Contents (United Kingdom)

PurposeThis prospective study followed 61 patients who were partially dentulous and considered to have insufficient bone volume for routine implant treatment and consequently underwent sinus inlay bone grafting.Patients and MethodsThe patients were treated with maxillary sinus floor augmentation with particulated autogenous bone from the mandibular ramus/corpus. After a healing period, dental implants (n = 180) were installed.ResultsRadiographic examination revealed average residual vertical bone heights of 6.5 mm in the first premolar region, 3.8 mm in the second premolar region, 3.5 mm in the first molar region, and 2.6 mm in the second molar region. The average implant lengths were 12 mm in the first premolar region and 11 mm in the second premolar, first, and second molar regions. All ...

2008-01-01

345

The Oxidation Behavior of CoCrAlY, CoCrAl and Yttrium ...  

Science.gov (United States)

... ADD137758. Title : The Oxidation Behavior of CoCrAlY, CoCrAl and Yttrium-Implanted CoCrAl Alloys Compared and Contrasted,. ...

1987-11-01

346

Temporal Interactions during Paired-Electrode Stimulation in Two Retinal Prosthesis Subjects  

UK PubMed Central (United Kingdom)

Purpose.Since 2002, six blind patients have undergone implantation of an epiretinal 4 × 4 electrode array designed to directly stimulate the remaining cells of the retina...Full Text Available

2011-01-01

347

Simulation of p-type diffusion in compound semiconductor: the case of beryllium implanted in InGaAs  

Energy Technology Data Exchange (ETDEWEB)

A system of equations describing transient enhanced diffusion of beryllium in InGaAs due to kick-out mechanism or due to formation, migration, and dissociation of the pairs ''beryllium atom-group III self-interstitial'' is proposed and analyzed. Simulation of coupled diffusion of beryllium atoms and self-interstitials in InGaAs during rapid thermal annealing was done for the case of dual implantation. For the experiment under consideration the first ion implantation of phosphorus atoms produced the region of extended defects that led to ''uphill'' diffusion of implanted Be in the defect region and in the vicinity of the surface. The suggested reason of ''uphill'' diffusion could be related to the nonuniform distribution of group III self-interstitials that was formed due to the absorption of point defects on the ...

2006-10-15

348

Removable Partial Denture in a Cleft Lip and Palate Patient: A Case Report  

UK PubMed Central (United Kingdom)

This clinical report described the oral rehabilitation of a cleft lip and palate patient with removable partial denture. Although implant-supported fixed treatment was presented as part of the optimum...Full Text Available

2008-10-01

349

Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy  

Energy Technology Data Exchange (ETDEWEB)

Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly ...

1997-09-01

350

Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy  

International Nuclear Information System (INIS)

Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly ...

1996-09-15

351

Prospective randomized controlled trial of an injectable esophageal prosthesis versus a sham procedure for endoscopic treatment of gastroesophageal reflux disease  

UK PubMed Central (United Kingdom)

BackgroundThis study aimed to assess whether endoscopic implantation of an injectable esophageal prosthesis, the Gatekeeper Reflux Repair System (GK), is a safe and effective therapy...Full Text Available

2010-06-01

352

Previous heat treatment inducing different plasma nitriding behaviors in martensitic stainless steels  

International Nuclear Information System (INIS)

In this work we report a study of the induced changes in structure and corrosion behavior of martensitic stainless steels nitrided by plasma immersion ion implantation (PI"3) at different previous heat treatments. The samples were characterized by x-ray diffraction and glancing angle x-ray diffraction, scanning electron microscopy, energy dispersive x-ray spectroscopy, and potentiodynamic measurements. Depending on the proportion of retained austenite in the unimplanted material, different phase transformations are obtained at lower and intermediate temperatures of nitrogen implantation. At higher temperatures, the great mobility of the chromium yields CrN segregations like spots in random distribution, and the #alpha#"'-martensite is degraded to#alpha#-Fe (ferrite). The nitrided layer thickness follows a fairly linear relationship with the temperature and a parabolic law with the process time. The corrosion resistance depends strongly on ...

2006-09-01

353

Plasma immersion ion implantation (PIII) of metals; Plasmaimmersionsionenimplantation metallischer Werkstoffe  

Energy Technology Data Exchange (ETDEWEB)

Plasma Immersion Ion Implantation (PIII) is a new hybrid technology for surface treatment of materials based on the principles of plasma nitriding and ion implantation. The equipment and the operation of the system are introduced. As well as providing an alternate method of ion implantation, it is possible to combine energetic ion bombardment with plasma nitriding. Different metal materials and treatment conditions have been studied. The capability of PIII-treatment to improve the properties of a wide range of metals has been proven. Application for forming tools and their industrial test has been successful. (orig.) [Deutsch] Die Plasmaimmersionsimplantation (PIII) ist eine neue Hybridtechnologie zur Behandlung von Werkstoffoberflaechen und basiert auf den Prinzipien des Plasmanitrierens und der Ionenimplantation. Die Anlagentechnik und die Arbeitsweise werden vorgestellt. Verfahrensspezifische Vorteile entstehen durch die ...

1995-01-01

354

Palliation of malignant esophageal obstruction and fistulas with self expandable metallic stents  

UK PubMed Central (United Kingdom)

AIM: To evaluate the efficacy of self expandable metallic stents (SEMS) in patients with malignant esophageal obstruction and fistulas.METHODS: SEMS were implanted in the presence of fluoroscopic...Full Text Available

2010-12-07

355

Oxygen-concentration dependent enhancement of positive secondary ion emission from silicon  

Energy Technology Data Exchange (ETDEWEB)

The enhancement of positive secondary ion yields of silicon due to the presence of oxygen has been investigated quantitatively by low-energy (5 keV) oxygen implantation. Implantation and sputter profiling with 9 keV In/sup +/ were performed in the same ion microprobe instrument. Depth profiles of substrate and implanted oxygen atoms were measured for fluences ranging from 5x10/sup 15/ to 4x10/sup 16/ O-atoms/cm/sup 2/. The oxygen concentration, c(O), in the sample was deduced from the implanted fluence and the range distribution in the Gaussian approximation. It was found that the oxygen-enhanced Si/sup +/ intensity is proportional to c(O)sup(x) (with x=1.4) in the concentration regime, 1.5<=c(O)<=30 at%. The O/sup +/ intensity shows a similar dependence for c(O)> or approx.20 at.%.

1983-12-15

356

Neointimal hyperplasia persists at six months after sirolimus-eluting stent implantation in diabetic porcine  

UK PubMed Central (United Kingdom)

BackgroundObservational clinical studies have shown that patients with diabetes have less favorable results after percutaneous coronary intervention compared with the non-diabetic...Full Text Available

357

Morbidity using subcutaneous ports and efficacy of vancomycin flushing in cancer.  

UK PubMed Central (United Kingdom)

An evaluation of totally implanted venous access systems inserted in 163 consecutive children with cancer is reported. From 1988 to 1994, 180 subcutaneous ports were inserted in children more than 1...Full Text Available

1995-04-01

358

MRT in differentiation between tumour and implant material in the postoperative sella. Differenzierung zwischen Tumor und Implantatmaterial in der postoperativen Sella mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T[sub 1] weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method ...

1993-06-01

359

MRT in differentiation between tumour and implant material in the postoperative sella  

International Nuclear Information System (INIS)

MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T_1 weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method of ...

360

Left Main Stent Thrombosis Complicated by Eptifibatide-Induced Acute Thrombocytopenia  

UK PubMed Central (United Kingdom)

A 57-year-old man with a history of coronary artery disease and placement of an implantable cardioverter-defibrillator presented at our emergency room with an anterior ST-elevation myocardial infarction....Full Text Available

2011-01-01

361

Heterotopic transcatheter tricuspid valve implantation: first-in-man application of a novel approach to tricuspid regurgitation  

UK PubMed Central (United Kingdom)

AimsTranscatheter treatment of heart valve disease is well established today. However, for the treatment of tricuspid regurgitation (TR), no effective catheter-based approach is...Full Text Available

2011-05-01

362

Expression of calbindin-D28k and its regulation by estrogen in the human endometrium during the menstrual cycle  

UK PubMed Central (United Kingdom)

Human endometrium resists embryo implantation except during the 'window of receptivity'. A change in endometrial gene expression is required for the development of receptivity. Uterine calbindin-D28k...Full Text Available

363

Experiments on the formation of the A 15-compounds Nb-Sn and Nb-Ge by ion implantation  

International Nuclear Information System (INIS)

Nb_3Sn films (Tsub(c)=17.8 K) were obtained by implantation of Sn"+ ions into Nb films (1500 A thick) after subsequent annealing. The annealing temperature required for the formation of the A15 phase in the implanted films was about 100 K higher than for Nb-Sn sandwich films evaporated at 300 K. The influence of the Sn concentration and of the annealing temperature was studied by measuring the sample resistance. The Nb-Sn compounds formed during the annealing process were analysed by measurements of the Moessbauer-effect of "1"1"9Sn. The implantation method was also used to produce Nb-Ge films with a ratio Ge/Nb approximately 1/3. The Ge-concentration and the temperature of the Nb-target (300-1070 K) were varied. These variations as well as subsequent annealing at 600-850"0C did not lead to superconducting transition temperatures above 8 K. (Auth.).

364

Effects of introducing low-frequency harmonics in the perception of vocoded telephone speech1  

UK PubMed Central (United Kingdom)

Several studies have demonstrated that telephone use presents a challenge for most cochlear implant (CI) users, and this is attributed mainly to the narrow bandwidth (300–3400 Hz) introduced...Full Text Available

2010-09-01

365

Effects of an Alpha-4 Integrin Inhibitor on Restenosis in a New Porcine Model Combining Endothelial Denudation and Stent Placement  

UK PubMed Central (United Kingdom)

Restenosis remains the main complication of balloon angioplasty and/or stent implantation. Preclinical testing of new pharmacologic agents preventing restenosis largely rely on porcine models, where...Full Text Available

366

Effect of energy and dose on transient-enhanced diffusion and defect microstructure in low energy high dose As{sup +} implanted Si  

Energy Technology Data Exchange (ETDEWEB)

(001) CZ silicon wafers were implanted with arsenic (As{sup +}) at energies of 10--50 keV to doses of 2 {times} 10{sup 14} to 5 {times} 10{sup 15}/cm{sup 2}. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface recombination of ...

1997-11-01

367

Effect of energy and dose on transient-enhanced diffusion and defect microstructure in low energy high dose As"+ implanted Si  

International Nuclear Information System (INIS)

(001) CZ silicon wafers were implanted with arsenic (As"+) at energies of 10--50 keV to doses of 2 x 10"1"4 to 5 x 10"1"5/cm"2. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface recombination of point defects, As ...

1996-12-02

368

Diffusion simulations of boron implanted at low energy (500 eV) in crystalline silicon  

Energy Technology Data Exchange (ETDEWEB)

Several models have been proposed for the simulation of boron diffusion during annealing after implantation in silicon. It has been shown that transient enhanced diffusion (TED) tends to disappear at sub-keV implant energies. Under these conditions boron concentration is higher than the boron solubility limit value, precipitation phenomena occur. Extended defects ({l_brace}3 1 1{r_brace}, EOR) formation and boron precipitation affect both the redistribution during the annealing and activation of the boron. For these reasons, we have investigated the diffusion of low energy boron implanted in crystalline silicon and tested a complete simulation program which takes into account the effects of type I defects as a sink for self-interstitials and of boron precipitation. Experimental results have been simulated and consistent parameters have been found to fit the data. Boron enhanced diffusion effect has been studied. Model ...

2004-02-01

369

Diffusion simulations of boron implanted at low energy (500 eV) in crystalline silicon  

International Nuclear Information System (INIS)

Several models have been proposed for the simulation of boron diffusion during annealing after implantation in silicon. It has been shown that transient enhanced diffusion (TED) tends to disappear at sub-keV implant energies. Under these conditions boron concentration is higher than the boron solubility limit value, precipitation phenomena occur. Extended defects (#left brace#3 1 1#right brace#, EOR) formation and boron precipitation affect both the redistribution during the annealing and activation of the boron. For these reasons, we have investigated the diffusion of low energy boron implanted in crystalline silicon and tested a complete simulation program which takes into account the effects of type I defects as a sink for self-interstitials and of boron precipitation. Experimental results have been simulated and consistent parameters have been found to fit the data. Boron enhanced diffusion effect has been studied. ...

2004-02-01

370

Diffusion mechanism of implanted Be in GaAs  

Energy Technology Data Exchange (ETDEWEB)

The transient enhanced diffusion of low and high dose implanted beryllium in undoped gallium arsenide during post-implant rapid thermal annealing in the temperature range of 700-900 C for 60-240 s has been studied and successfully simulated by the kick-out diffusion model, involving singly positively charged Be interstitials and doubly positively charged Ga self-interstitials. Using the ''plus one'' approach for Ga interstitial generation after implantation with the local Ga interstitial sink concept as well as the appropriate initial and boundary conditions for involved mobile species, and taking into account Fermi-level and built-in electric field effects, the obtained partial differential equations have been solved numerically by means of an explicit finite difference method. The thermal equilibrium concentrations and the diffusivities of Be and Ga interstitials, all as a function of ...

2008-01-15

371

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so ...

372

Develop techniques for ion implantation of PLZT [lead-lanthanum-zirconate-titanate] for adaptive optics  

International Nuclear Information System (INIS)

Research was conducted at Pacific Northwest Laboratory to develop high photosensitivity adaptive optical elements utilizing ion implanted lanthanum-doped lead-zirconate-titanate (PLZT). One centimeter square samples were prepared by implanting ferroelectric and anti-ferroelectric PLZT with a variety of species or combinations of species. These included Ne, O, Ni, Ne/Cr, Ne/Al, Ne/Ni, Ne/O, and Ni/O, at a variety of energies and fluences. An indium-tin oxide (ITO) electrode coating was designed to give a balance of high conductivity and optical transmission at near uv to near ir wavelengths. Samples were characterized for photosensitivity; implanted layer thickness, index of refraction, and density; electrode (ITO) conductivity; and in some cases, residual stress curvature. Thin film anti-ferroelectric PLZT was deposited in a preliminary experiment. The structure was amorphous with x-ray diffraction showing the beginnings of ...

373

Corrosion and histopathological studies on anode materials for implantable power sources. [In vivo corrosion studies on anode material  

Science.gov (United States)

The biocompatibility and corrosion resistance of various materials for use as sacrificial anodes in in vivo hybrid fuel cells were studied. Aluminium, zinc, and magnesium alloy AZ31B were studied, and the results are discussed.

1974-01-01

374

Comparison and co-relation of invasive and noninvasive methods of ejection fraction measurement.  

UK PubMed Central (United Kingdom)

BACKGROUND: Accurate estimation of left ventricular ejection fraction (LVEF) has assumed great significance in the era of automatic implantable cardioverter defibrillators (AICDs), and a low EF may...Full Text Available

2007-11-01

375

CoSi_2 nanostructures by writing FIB ion beam synthesis  

International Nuclear Information System (INIS)

A mass separated focused ion beam (FIB) is a very useful tool to fabricate nanostructures by writing implantation within an ion beam synthesis process. In these investigations the IMSA-OrsayPhysics FIB, equipped with a Co_3_6Nd_6_4 alloy liquid metal ion source, was applied. Si(100) and (111) wafers were implanted with 60 keV Co"+"+ ions in the dose range of 2 . 10"1"6 to 2 . 10"1"7 cm"-"2. Implantation parameters were investigated, like pixel dwell time, relaxation time (time between two cycles), dose rate as well as the pixel overlapping factor. The subsequent annealing was done in a two step process, namely 600 deg. C for 60 min and 1000 deg. C for 30 min in a N_2 ambient. The results obtained by SEM investigations in terms of continuous nanowire structures following the direction and interrupted CoSi_2 pattern in the direction show a clear dependence on the time scale as well as the scanning mode of the irradiation. ...

2006-07-01

376

Circulation, bone scans, and tetracycline labeling in microvascularized and vascular bundle implanted rib grafts  

Energy Technology Data Exchange (ETDEWEB)

The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized ...

1984-11-01

377

Characterization of iron nitrides prepared by spark erosion, plasma nitriding, and plasma immersion ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The effect of the nitrogen uptake in {alpha}-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic {alpha}-Fe phase (50%). The 20% of specimen volume form {alpha}'-Fe and {alpha}''-Fe{sub 16}N{sub 2} phases. The last 30% occupy the {gamma}'-Fe{sub 4}N, ferro- and paramagnetic {epsilon} phases, and {gamma}-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into {alpha}-iron particles which results in the formation of paramagnetic {epsilon}({zeta})-Fe{sub 2}N phase. This phase also dominates the surface of {alpha}-iron ...

2001-09-01

378

Characterization of iron nitrides prepared by spark erosion, plasma nitriding, and plasma immersion ion implantation  

International Nuclear Information System (INIS)

The effect of the nitrogen uptake in #alpha#-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic #alpha#-Fe phase (50%). The 20% of specimen volume form #alpha#'-Fe and #alpha#''-Fe_1_6N_2 phases. The last 30% occupy the #gamma#'-Fe_4N, ferro- and paramagnetic #epsilon# phases, and #gamma#-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into #alpha#-iron particles which results in the formation of paramagnetic #epsilon#(#zeta#)-Fe_2N phase. This phase also dominates the surface of #alpha#-iron specimen implanted by nitrogen using ...

2001-09-01

379

Case series of maxillary sinus augmentation with biphasic calcium phosphate: a clinical and radiographic study  

UK PubMed Central (United Kingdom)

PurposeThe aim of this study was to evaluate 3.5 years-cumulative survival rate of implants placed on augmented sinus using Osteon, a bone graft material, and to assess the height...Full Text Available

2011-04-01

380

Case Reports: Fractures of Threaded Cups: Rare Complications of a Well-established Implant  

UK PubMed Central (United Kingdom)

The use of cementless threaded cups in THA is a well-established treatment. Fractures of the cups are rare complications recorded in individual cases with material defects being discussed as the primary...Full Text Available

2009-03-01

381

Boron-enhanced diffusion of boron from ultralow-energy ion implantation  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050&hthinsp;{degree}C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1{percent} and 10{percent}, though it appears to be closer to 1{percent} for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3{times}10{sup 14} and 1{times}10{sup 15} cm{sup {minus}2}. It is proposed that the excess interstitials responsible for BED are produced during ...

1999-04-01

382

Boron-enhanced diffusion of boron from ultralow-energy ion implantation  

International Nuclear Information System (INIS)

We have investigated the diffusion enhancement mechanism of boron-enhanced diffusion (BED), wherein boron diffusivity is enhanced four to five times over the equilibrium diffusivity at 1050 ampersand hthinsp;degree C in the proximity of a silicon layer containing a high boron concentration. It is demonstrated that BED is driven by excess interstitials injected from the high boron concentration layer during annealing. For evaporated layers, BED is observed above a threshold boron concentration between 1% and 10%, though it appears to be closer to 1% for B-implanted layers. For sub-keV B implants above the threshold, BED dominates over the contribution from transient-enhanced diffusion to junction depth. For 0.5 keV B, this threshold implantation dose lies between 3x10"1"4 and 1x10"1"5 cm"-"2. It is proposed that the excess interstitials responsible for BED are produced during the formation of a silicon boride phase in the ...

1999-04-01

383

Atomistic calculations of ion implantation in Si: Point defect and transient enhanced diffusion phenomena  

Energy Technology Data Exchange (ETDEWEB)

A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5{times}10{sup 13} cm{sup {minus}2} Si into (001)Si, followed by a high temperature (815{degree}C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the {open_quote}{open_quote}+1{close_quote}{close_quote} model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in ...

1996-01-01

384

Atomistic calculations of ion implantation in Si: Point defect and transient enhanced diffusion phenomena  

International Nuclear Information System (INIS)

A new atomistic approach to Si device process simulation is presented. It is based on a Monte Carlo diffusion code coupled to a binary collision program. Besides diffusion, the simulation includes recombination of vacancies and interstitials, clustering and re-emission from the clusters, and trapping of interstitials. We discuss the simulation of a typical room-temperature implant at 40 keV, 5x10"1"3 cm"-"2 Si into (001)Si, followed by a high temperature (815 degree C) anneal. The damage evolves into an excess of interstitials in the form of extended defects and with a total number close to the implanted dose. This result explains the success of the open-quote open-quote+1 close-quote close-quote model, used to simulate transient diffusion of dopants after ion implantation. It is also in agreement with recent transmission electron microscopy observations of the number of interstitials stored in (311) defects. copyright 1996 ...

385

Annealing behavior of radiation damages in metal-silicides  

International Nuclear Information System (INIS)

The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).

386

Toward a predictive atomistic model of ion implantation and dopant diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

We review the development and application of kinetic Monte Carlo simulations to investigate defect and dopant diffusion in ion implanted silicon. In these type of Monte Carlo models, defects and dopants are treated at the atomic scale, and move according to reaction rates given as input principles. These input parameters can be obtained from first principles calculations and/or empirical molecular dynamics simulations, or can be extracted from fits to experimental data. Time and length scales differing several orders of magnitude can be followed with this method, allowing for direct comparison with experiments. The different approaches are explained and some results presented.

1998-09-18

387

Reduced boron diffusion under interstitial injection in fluorine implanted silicon  

International Nuclear Information System (INIS)

Point defect injection studies are performed to investigate how fluorine implantation influences the diffusion of boron marker layers in both the vacancy-rich and interstitial-rich regions of the fluorine damage profile. A 185 keV, 2.3x10"1"5 cm"-"2 F"+ implant is made into silicon samples containing multiple boron marker layers and rapid thermal annealing is performed at 1000 deg. C for times of 15-120 s. The boron and fluorine profiles are characterized by secondary ion mass spectroscopy and the defect structures by transmission electron microscopy (TEM). Fluorine implanted samples surprisingly show less boron diffusion under interstitial injection than those under inert anneal. This effect is particularly noticeable for boron marker layers located in the interstitial-rich region of the fluorine damage profile and for short anneal times (15 s). TEM images show a band of dislocation loops around the range of the fluorine ...

2007-12-01

388

Randomization of heavily damaged regions in annealed low energy Ge{sup +}-implanted (0 0 1)Si  

Energy Technology Data Exchange (ETDEWEB)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge{sup +}-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-15

389

Randomization of heavily damaged regions in annealed low energy Ge"+-implanted (0 0 1)Si  

International Nuclear Information System (INIS)

Apparent growth of amorphous layers during low temperature annealing was observed in low energy Ge"+-implanted (0 0 1)Si by high-resolution transmission electron microscopy. The occurrence of abnormal growth is due to the randomization of heavily damaged regions beneath the original amorphous/crystalline interfaces. The randomization process is attributed to the strain, incurred by the presence of a high density of large Ge atoms in the heavily damaged Si substrate, relaxation to lower the free energy of the systems. The randomization upon annealing may be fruitfully applied to minimize the transient enhanced diffusion in shallow junction formation.

2004-01-01

390

Plasma source ion implantation of ammonia into electroplated chromium  

Energy Technology Data Exchange (ETDEWEB)

Ammonia gas (NH{sub 3}) has been used as a nitrogen source for plasma source ion implantation processing of electroplated chromium. No evidence was found of increased hydrogen concentrations in the bulk material, implying that ammonia can be used without risking hydrogen embrittlement. The retained nitrogen dose of 2.1 {times} 10{sup 17} N-at/cm{sup 2} is sufficient to increase the surface hardness of electroplated Cr by 24% and decrease the wear rate by a factor of 4.

1995-02-01

391

Low temperature proton irradiation of amorphous Pd/sub 80/Si/sub 20/ prepared by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The damage induced by low-temperature proton irradiation in amorphous Pd/sub 80/Si/sub 20/ prepared by ion implantation is studied via electrical resistivity measurements. Our experimental results concerning the initial damage rate and the resistivity saturation are compared to the results obtained for electron and high energy /sup 16/O irradiation of amorphous Pd/sub 80/Si/sub 20/ quenched from the melt. The resistivity curve is analyzed in terms of irradiation-induced point defects.

1984-05-01

392

Implantation of single-impurity Fe and its magnetic coupling in Er studied by TDPAD  

Energy Technology Data Exchange (ETDEWEB)

Single Fe impurities were implanted in an Er single crystal and found to occupy both substitutional and interstitial sites, below a temperature of 200 K. The local susceptibility of Fe on both sites follows a Curie-Weiss law and exhibits a positive local Curie constant, indicating an antiferromagnetic coupling between the Fe and the surrounding Er moments. The corresponding nuclear spin relaxation rates follow a Korringa law as a function of temperature, confirming the dominance of local magnetism and the formation of local moments on each of the sites occupied by Fe.

2004-05-01

393

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

394

Free electron laser (FEL) annealing of diamond  

International Nuclear Information System (INIS)

Free Electron Laser (FEL) with wide wavelength tunability has been developed and used for various applications. We report the structural-changes in P-ion-implanted diamond when we can achieve resonant excitation of the vibrations of specific bonds in the lattice of target (P-C) by using FEL. The change of property was analyzed by SIMS and Raman spectroscopy. After 5.8 #mu#m-FEL irradiation, we observed the crystallization of amorphous structure which was induced by P-ion-implantation. These results indicated the FEL annealing of diamond at room temperature. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

1998-09-02

395

Effects of avalanche hole injection in fluorinated SiO[sub 2] MOS capacitors  

Energy Technology Data Exchange (ETDEWEB)

Significantly improved immunity to hot-hole damage of the SiO[sub 2]/Si structure is achieved by a shallow fluorine implantation into the poly-Si gate of MOS capacitors followed by a drive-in process. Compared to the nonfluorinated control, the fluorinated samples exhibit a dramatic reduction of both hole trapping probability and interface-trap generation under avalanche hole injection conditions. The degree of such an improvement increases monotonically as a function of the F implantation dose (up to 10[sup 16]/cm[sup 2]). Significant decrease of the hole detrapping rate is also observed in fluorinated samples. Possible mechanisms are discussed.

1993-04-01

396

Dextranomer/hyaluronic acid copolymer (Deflux) implants mimicking distal ureteral calculi on CT  

Energy Technology Data Exchange (ETDEWEB)

Periureteral or subtrigonal injection of dextranomer/hyaluronic acid (Dx/HA) copolymer (Deflux, Q-Med, Uppsala, Sweden) is an increasingly common endoscopic treatment for vesicoureteral reflux. We report a confusing radiographic finding of bilateral calcified Dx/HA injections initially thought to represent bilateral distal ureteral stones in a boy who presented with intermittent periumbilical pain. Urologists, radiologists, and emergency room physicians should be aware of the potential for calcification of ureteral implants of Dx/HA, and of the potentially confusing radiographic images that may result. (orig.)

2008-01-15

397

Defect engineering via ion implantation to control B diffusion in Si  

International Nuclear Information System (INIS)

The processes which are currently studied in the fabrication of B-doped ultra shallow junctions (USJ) usually involve a preamorphization step to reduce B channelling effect during implantation and to improve B electrical activation. At this stage a high amount of Si interstitial atoms (Is), which dramatically increases the B diffusivity, is introduced. The introduction of voids in Si is a promising tool to control B transient enhanced diffusion (TED), because of their ability to capture Is. In this work the efficiency of a cavity band to reduce B TED is checked in silicon interstitial supersaturation conditions, obtained by high dose Si implantation. He is implanted either at 10 keV or at 50 keV with a fluence of 5 x 10"1"6 cm"-"2. Conventional techniques to introduce and activate the B (conventional ion implantation and rapid thermal annealing (RTA)) are applied in order to have a better control of the ...

2009-03-15

398

Characterization and wear tests of steel surfaces implanted with oxygen, aluminum, and carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

A number of screening tests were performed to determine ion species that effectively reduce wear rates when implanted in four industrial steels. Ball bearing steel 100Cr6 (AISI 52100) showed a wear rate reduction by a factor of 20 when implanted with carbon dioxide to a dose of 5x10{sup 17} cm{sup -2} with a non-mass-separated ion beam and by a factor of {>=}20 when implanted with 5x10{sup 17} cm{sup -2} oxygen ions. For the ferritic and martensite steels X90CrMoV18 (AISI 440B, unhardened and hardened) also a strong wear reduction after implantation of oxygen ions was found. Co-implantation of aluminum and oxygen also reduces wear rates of X90CrMoV18, of S6-5-2 (AISI M2), and of 100Cr6, respectively. For comparison, thin oxide layers were grown in a low-temperature thermal oxidation process. These experiments also yielded reduced wear rates by a factor of 10. The surfaces were ...

1991-07-01

399

Boron depth profiles and residual damage following rapid thermal annealing of low-temperature BSi molecular ion implantation in silicon  

Energy Technology Data Exchange (ETDEWEB)

The influence of substrate temperature on both the implantation and post-annealing characteristics of molecular-ion-implanted 5 x 10{sup 14} cm{sup -2} 77 keV BSi in silicon was investigated in terms of boron depth profiles and damage microstructures. The substrate temperatures under investigation consisted of room temperature (RT) and liquid nitrogen temperature (LT). Post-annealing treatments were performed using rapid thermal annealing (RTA) at 1050 deg, C for 25 s. Boron depth profiles and damage microstructures in both the as-implanted and as-annealed specimens were determined using secondary ion mass spectrometry (SIMS) and transmission electron microscopy (TEM), respectively. The as-implanted results revealed that, compared to the RT specimen, the LT specimen yields a shallower boron depth profile with a reduced tail into the bulk. An amorphous layer containing a smooth amorphous-to-crystalline ...

2007-08-15

400

[Heart injuries: diagnosis and therapy].  

Science.gov (United States)

The clinical manifestation of wounds of the heart is determined by the mode, site and size of the injury as well as the structure of the pericardial and myocardial lesion. Diagnosis can be confirmed by ECG and echocardiography. Only 20% of the patients with penetrating wounds of the heart live for more than 30 minutes. Pericardio-centesis should be used only to gain time for a safe sternotomy, cardiac decompression and suture of the wound of the heart. An aggressive surgical approach is mandatory. Cardiopulmonary bypass is necessary only to correct of concomitant lesions. PMID:1983618

1990-01-01

401

[Enzymatic pancreatogenic omental bursitis].  

Science.gov (United States)

The most common causes of omental sac collections (OSC) are necrotic pancreatitis (90%) and pancreatic trauma (10%). Acute OSC is a form of local peritonitis in acute pancreatitis, subacute OSC are caused by internal pancreatic fistulas. The clinical and radiological signs, enzymatic activity of the exudate, morphological features of peritonitis were investigated. Treatment of acute OSC included conservative measures, of subacute OSC-surgical procedures. PMID:9163152

1996-01-01

402

True aneurysm originating from the costocervical trunk: surgical excision for recurrence after successful proximal coil embolization.  

Science.gov (United States)

A rare, true aneurysm of a branch of the right subclavian artery is described. Transcatheter coil embolization of the feeder artery was successful in obliterating blood flow into the aneurysm and the mass reduced in size. However, the aneurysm reenlarged over the next week of follow-up due to development and enlargement of the collateral vascular network. Extirpation of the aneurysm was performed. Histopathological examination revealed a true aneurysm. PMID:11833847

2002-01-01

403

Role of CT in TNM staging of laryngeal and hypopharyngeal tumors  

International Nuclear Information System (INIS)

70 patients with squamouscell carcinoma of larynx and hypopharynx were examined by computed tomography; the TNM staging of tumors by CT, by endoscopy and by surgical operation was reviewed. CT proved to be reliable both to recognize the presence of neoplasms, with the exception of those very superficial, and their deep spreading to preepiglottic and paralaryngeal spaces, to the soft tissues of the neck and to the cartilages. Therefore CT is the examination of choice in laryngeal neoplasms staging, because it precisely completes the clinical and endoscopical informations.

1986-01-01

404

Nuclear methods monitor nutrition  

International Nuclear Information System (INIS)

Neutron activation of nitrogen and hydrogen in the body, the isotope dilution technique and the measurement of naturally radioactive potassium in the body are among the new nuclear methods, now under collaborative development by the Australian Nuclear Scientific and Technology Organization and medical specialists from several Sydney hospitals. These methods allow medical specialists to monitor the patient's response to various diets and dietary treatments in cases of cystic fibrosis, anorexia nervosa, long-term surgical trauma, renal diseases and AIDS. ills.

405

Imaging findings of central nervous system neuroepithelial cysts  

Energy Technology Data Exchange (ETDEWEB)

Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.

1998-05-01

406

Hypodiploidy, Ki-67 growth fraction and prognosis of surgically resected lung cancers.  

UK PubMed Central (United Kingdom)

One hundred and thirty-seven lung cancer patients (123 non-small-cell lung cancers (NSCLC), 10 small-cell lung cancers (SCLC) and four carcinoid tumours) who underwent surgery in an attempt at complete...Full Text Available

1996-09-01

407

Endocavitary radiotherapy of rectal tumours; Endokavitaer straalebehandling ved distale rectum tumorers  

Energy Technology Data Exchange (ETDEWEB)

The authors describe their experience of endocavitary radiotherapy of adenomas and carcinomas of the lower rectum. The method is an alternative for patients who cannot undergo standard surgical procedure or do no want a permanent colostomy. This method is cheap, fast and causes little discomfort to the patients, gives reasonable long-term results and has low morbidity. 11 refs., 4 figs., 2 tabs.

1997-02-01

408

Cerebral sparganosis. Case report.  

Science.gov (United States)

The tapeworm Spirometra mansonoides infects man worldwide, particularly in Asian countries. Rarely, the central nervous system is involved; such a case is presented here. In the total of 12 reported cases, including the case described, the worm presented clinically as a mass suspicious for neoplasm or chronic abscess cavity. Surgical removal was invariably curative in each case. Although infrequent, the possibility of tapeworm infection should be entertained in the evaluation of intracranial masses in patients who have visited exotic locales. PMID:2191089

1990-07-01

409

Case of an unusual clinical and radiological presentation of pulmonary metastasis from a costal chondrosarcoma after wide surgical resection: A transbronchial biopsy is recommended  

UK PubMed Central (United Kingdom)

Chondrosarcomas are the most frequently occurring primary malignant chest wall tumors. Furthermore, the lungs serve as the most frequent sites for metastases. Pulmonary metastases from sarcomas usually...Full Text Available

410

CT manifestations of ileal dysgenesis  

Energy Technology Data Exchange (ETDEWEB)

Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)

2007-02-15

411

Biosoluble surgical material from 2,3-dialdehyde cellulose.  

Science.gov (United States)

Dialdehyde cellulose (DAC) was prepared by periodate oxidation of various cellulosic materials in the form of sutures and bandages. The suitability of using DAC for making bioabsorbable sutures and antimicrobial wound dressing bandages was studied. The investigations indicated that DAC combines the requisite mechanical strength with an inherent antimicrobial nature. It was found that the oxidation of cellulose to yield DAC also rendered it bioabsorbable. The DAC was coated with different concentrations of urea formaldehyde in order to improve the mechanical properties for making sutures. PMID:3719037

1986-05-01

412

Analysis of Computer Experiments with Multiple Noise Sources  

DEFF Research Database (Denmark)

In this paper we present a modeling framework for analyzing computer models with two types of variations. The paper is based on a case study of an orthopedic surgical unit, which has both controllable and uncontrollable factors. Our results show that this structure of variation can be modeled effectively with linear mixed effects models and generalized additive models. Copyright (C) 2009 John Wiley & Sons, Ltd.

2010-01-01

413

Eelgrass Enhancement and Restoration in the Lower Columbia River Estuary, Period of Performance: Feb 2008-Sep 2009.  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the ability to enhance distribution of eelgrass (Zostera marina) in the Columbia River Estuary to serve as refuge and feeding habitat for juvenile salmon, Dungeness crab, and other fish and wildlife. We strongly suspected that limited eelgrass seed dispersal has resulted in the present distribution of eelgrass meadows, and that there are other suitable places for eelgrass to survive and form functional meadows. Funded as part of the Bonneville Power Administration's call for Innovative Projects, we initiated a multistage study in 2008 that combined modeling, remote sensing, and field experimentation to: (1) Spatially predict habitat quality for eelgrass; (2) Conduct experimental plantings; and (3) Evaluate restoration potential. Baseline in-situ measurements and remote satellite observations were acquired for locations in the Lower Columbia River Estuary (LCRE) to determine ambient habitat conditions. These were ...

2009-09-08

414

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to ...

2000-08-01

415

The effects of energy non-monochromaticity of "1"1B ion beams on "1"1B diffusion  

International Nuclear Information System (INIS)

We have shown that energy contamination introduced by ion beam deceleration technology that is used to increase the beam currents available for low energy boron implants, can affect fabricated junctions adversely. A 4 keV "1"1B beam is extracted and retarded by a potential of -3.5 keV for 0.5 keV "1"1B implantation, or by a potential of -3.8 keV for 0.2 keV "1"1B implantation. Intentional beam contamination was introduced by turning off the retarding potential to allow the 4 keV "1"1B ions to irradiate Si wafers directly. The percentage of contamination, at levels of 0.1%, 0.2% and 0.3% was introduced. Rapid thermal annealing of all the implanted samples was performed under N_2 ambient at 1050 deg. C for 1 s. The dopant tail profiles themselves are not significant if the contamination levels are low. However, the much higher damage level coming from high energy contamination increases the transient ...

2005-08-01

416

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors; Combined with hyperthermia  

Energy Technology Data Exchange (ETDEWEB)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial ...

1990-05-01

417

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors  

International Nuclear Information System (INIS)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial ...

1990-01-01

418

Si and Si/P implants in In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P  

Science.gov (United States)

Si and Si/P ion implantation doping of In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P has been studied for several Si and P doses at energies of 90 and 100 keV, respectively. For single Si implants in InGaP a maximum Hall sheet electron concentration of 1.33{times}10{sup 13} cm{sup {minus}2} is achieved for a Si dose of 5{times}10{sup 13} cm{sup {minus}2}. When an optimum dose (2.5{times}10{sup 13} cm{sup {minus}2}) P coimplant is performed this electron concentration is increased by 65{percent}. The same dose Si implants in InAlP show a maximum effective activation of 3.9{percent} with no P coimplantation and 5.2{percent} with a P-implant dose 1.5 times the silicon dose. The apparent donor ionization energies are estimated from variable temperature Hall measurements to be 2{endash}5 meV for InGaP and {approximately}80 meV for InAlP. The deeper level in InAlP is attributed to the DX level found in ...

1996-06-01

419

On Boron Diffusion in MgF{sub 2}  

Science.gov (United States)

The MgF{sub 2} monocrystals were irradiated at room temperature with 390 keV B{sup +} ions up to the fluence of 10{sup 16} cm{sup -2}. The irradiated samples were (isochronally and isothermally) annealed in high vacuum at the temperatures 200 deg. C, 300 deg. C, 400 deg. C, 500 deg. C, 600 deg. C and 700 deg. C for the times ranging from 2-100 hours. After each annealing step, the boron depth distribution was determined using the neutron depth profiling technique. As implanted, the depth distributions of boron exhibited standard Gaussian-like forms, but the evaluated profile parameters, R{sub P} = 960 nm and {delta}R{sub P} = 140 nm, were higher than those calculated using the SRIM code (R{sub P} = 870 nm and {delta}R{sub P} = 115 nm). Annealing at temperatures up to 400 deg. C did not change the depth profiles. Annealing at 600 deg. C, however, led to a one-way gradual transfer of the boron atoms from the site of implantation towards the ...

2009-03-10

420

Nucleation, growth and dissolution of extended defects in implanted Si: impact on dopant diffusion  

Energy Technology Data Exchange (ETDEWEB)

Transient Enhanced Diffusion (TED) of boron in silicon is driven by the large supersaturations of self-interstitial silicon atoms left after implantation which also often lead to the nucleation and subsequent growth, upon annealing, of extended defects. In this paper we review selected experimental results and concepts concerning boron diffusion and/or defect behavior which have recently emerged with the ion implantation community and briefly indicate how they are, or will be, currently used to improve 'predictive simulations' softwares aimed at predicting TED. In a first part, we focus our attention on TED and on the formation of defects in the case of 'direct' implantation of boron in silicon. In a second part, we review our current knowledge of the defects and of the diffusion behavior of boron when annealing preamorphised Si. In a last part, we try to compare these two cases and to ...

1999-01-01

421

Nucleation, growth and dissolution of extended defects in implanted Si: impact on dopant diffusion  

International Nuclear Information System (INIS)

Transient Enhanced Diffusion (TED) of boron in silicon is driven by the large supersaturations of self-interstitial silicon atoms left after implantation which also often lead to the nucleation and subsequent growth, upon annealing, of extended defects. In this paper we review selected experimental results and concepts concerning boron diffusion and/or defect behavior which have recently emerged with the ion implantation community and briefly indicate how they are, or will be, currently used to improve 'predictive simulations' softwares aimed at predicting TED. In a first part, we focus our attention on TED and on the formation of defects in the case of 'direct' implantation of boron in silicon. In a second part, we review our current knowledge of the defects and of the diffusion behavior of boron when annealing preamorphised Si. In a last part, we try to compare these two cases and to find out what are the reasons for some ...

1999-01-01

422

Influence of irradiation spectrum and implanted ions on the amorphization of ceramics  

Energy Technology Data Exchange (ETDEWEB)

Polycrystalline Al2O3, magnesium aluminate spinel (MgAl2O4), MgO, Si3N4, and SiC were irradiated with various ions at 200-450 K, and microstructures were examined following irradiation using cross-section TEM. Amorphization was not observed in any of the irradiated oxide ceramics, despsite damage energy densities up to {similar_to}7 keV/atom (70 displacements per atom). On the other hand, SiC readily amorphized after damage levels of {similar_to}0.4 dpa at room temperature (RT). Si3N4 exhibited intermediate behavior; irradiation with Fe{sup 2+} ions at RT produced amorphization in the implanted ion region after damage levels of {similar_to}1 dpa. However, irradiated regions outside the implanted ion region did not amorphize even after damage levels > 5 dpa. The amorphous layer in the Fe-implanted region of Si3N4 did not appear if the specimen was simultaneoulsy irradiated with 1-MeV He{sup +} ions at RT. By comparison ...

1995-12-31

423

Adaptive meshing technique applied to an orthopaedic finite element contact problem.  

Science.gov (United States)

Finite element methods have been applied extensively and with much success in the analysis of orthopaedic implants. Recently a growing interest has developed, in the orthopaedic biomechanics community, in how numerical models can be constructed for the optimal solution of problems in contact mechanics. New developments in this area are of paramount importance in the design of improved implants for orthopaedic surgery. Finite element and other computational techniques are widely applied in the analysis and design of hip and knee implants, with additional joints (ankle, shoulder, wrist) attracting increased attention. The objective of this investigation was to develop a simplified adaptive meshing scheme to facilitate the finite element analysis of a dual-curvature total wrist implant. Using currently available software, the analyst has great flexibility in mesh generation, but must prescribe element ...

2004-01-01

424

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal involvement. Patients without ...

2000-08-01

425

Tribological behavior of duplex coating improved by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

In the present paper the tribological behavior of the coatings are discussed. Duplex coatings were applied on cold working steel 100Cr6. Samples were plasma nitrided at different thickness of plasma surface layers. TiN was deposited with a classic BALZERS PVD equipment and subsequent ion implantation. Ion implantation was provided with N{sup 5+} ions. The other samples were produced with IBAD technology in DANFYSIK chamber. Wear resistance and exchanges of friction coefficient were measured with on-line test using special designed tribology equipment. Following the tests, the wear zone morphology and characteristics of surface layer structure as well as important properties were investigated by scanning electron microscopy (SEM) and X-ray diffraction analysis (XRD). Scratch adhesion testing was performed using commercially available equipment. Energy dispersive X-ray analysis (EDAX) of the wear-scars on pins provided essential information on ...

2004-07-01

426

The Reduction of TED in Ion Implanted Silicon  

International Nuclear Information System (INIS)

The leading challenge in the continued scaling of junctions made by ion implantation and annealing is the control of the undesired transient enhanced diffusion (TED) effect. Spike annealing has been used as a means to reduce this effect and has proven successful in previous nodes. The peak temperature in this process is typically 1050 deg. C and the time spent within 50 deg. C of the peak is of the order of 1.5 seconds. As technology advances along the future scaling roadmap, further reduction or elimination of the enhanced diffusion effect is necessary. We have shown that raising the peak temperature to 1175 deg. C or more and reduction of the anneal time at peak temperature to less than a millisecond is effective in eliminating enhanced diffusion. We show that it is possible to employ a sequence of millisecond anneal followed by spike anneal to obtain profiles that do not exhibit gradient degradation at the junction and have junction depth and sheet resistance ...

2008-11-03

427

Study of iodine migration in zirconia using stable and radioactive ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using radioactive {sup 131}I ...

1998-03-01

428

Positioning of self-assembled InAs quantum dots by focused ion beam implantation  

International Nuclear Information System (INIS)

Self-assembled quantum dots (QDs) are envisioned as building blocks for realization of novel nanoelectronic devices, for which the site-selective growth is highly desirable. This thesis presents a successful route toward selective positioning of self-assembled InAs QDs on patterned GaAs surface by combination of in situ focused ion beam (FIB) implantation and molecular beam epitaxy (MBE) technology. First, a buffer layer of GaAs was grown by MBE before a square array of holes with a pitch of 1-2 #mu#m was fabricated by FIB implantation of Ga and In, ions respectively. Later, an in-situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by FIB. The influence of ion dose, annealing parameters and InAs amount was investigated in this work. With optimized parameters, more than 50 % single dot occupancy per hole is achieved. Furthermore, the photoluminescence spectra from ...

2006-07-01

429

Plasma nitriding of stainless steels at low temperatures  

Energy Technology Data Exchange (ETDEWEB)

To avoid the drop in corrosion resistance of stainless steels in conventional nitriding (precipitation of CrN), low-temperature techniques like ion implantation, plasma immersion ion implantation (PIII, PI{sup 3}) and low-temperature plasma nitriding were developed. In this investigation, four stainless-steel grades (ferritic: X6Cr17, austenitic-ferritic: X2CrNiMoN22.5.3, austenitic: X8CrNiTi18.10 and X5CrNi18.10) were plasma-nitrided between 250 and 500 C. Nitrogen-enriched layers with a high nitrogen content were produced, leading to a significant increase in surface hardness. X-ray diffraction indicated that CrN did not precipitate if treatment temperatures did not exceed 400 C. 'Expanded austenite' formed in the austenitic and duplex steels and {epsilon}-nitride (Fe{sub 2}N{sub 1-x}) in the ferritic steel. The optically visible structure of the nitrided cases is comparable with that of the PIII layers, with higher charging ...

1999-09-01

430

Optimization of advanced PMOS junctions using Ge, B and F co-implants  

International Nuclear Information System (INIS)

The main challenges for PMOS ultra shallow junction formation remain the transient enhanced diffusion (TED) and the solid solubility limit of boron in silicon. It has been demonstrated that low energy boron implantation and spike annealing are key in meeting the 90nm technology node ITRS requirements. To meet the 65nm technology requirements many studies have used fluorine co-implantation with boron and Si"+ or Ge"+ pre-amorphization (PAI) and spike annealing. Although using BF_2"+ can be attractive for its high throughput, self-amorphization and the presence of fluorine, many studies have shown that the fluorine successfully reduce TED, its energy needs to be well optimized with respect to the boron's, therefore BF_2"+ does not present the right fluorine/boron energy ratio for the optimum junction formation. In this work we optimize the fluorine energy for boron energies down to 200eV. We show the dependence of optimized junction on Ge"+ ...

2005-08-01

431

Kinetic Monte Carlo (KMC) simulations for boron diffusion in ion-implanted crystalline materials  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we report kinetic Monte Carlo study on the diffusion behavior of boron in silicon crystal, more particularly on the transient enhanced diffusion (TED) of boron in silicon during implantation and annealing. Firstly, the accuracy of our KMC code was verified by investigating the time evolutionary behavior of interstitial (I) and vacancy (V) when a silicon substrate is implanted with silicon dose with an energy of 10 keV and with a dose of 1 X 10{sup 14} ions/cm{sup 2}. To investigate the influence of native defects (I, V) on boron diffusion, a single and multi boron markers grown by MBE were employed. The simulation results revealed that the precursor of boron cluster (BI{sub 2}) is dominant at the initial stage of annealing, which explains the boron TED phenomenon in terms of the concentration of boron complexes and I, V clusters, respectively. The formation of {l_brace}311{r_brace} defects and dislocation loop were observed from ...

2004-11-15

432

Kinetic Monte Carlo (KMC) simulations for boron diffusion in ion-implanted crystalline materials  

International Nuclear Information System (INIS)

In this paper, we report kinetic Monte Carlo study on the diffusion behavior of boron in silicon crystal, more particularly on the transient enhanced diffusion (TED) of boron in silicon during implantation and annealing. Firstly, the accuracy of our KMC code was verified by investigating the time evolutionary behavior of interstitial (I) and vacancy (V) when a silicon substrate is implanted with silicon dose with an energy of 10 keV and with a dose of 1 X 10"1"4 ions/cm"2. To investigate the influence of native defects (I, V) on boron diffusion, a single and multi boron markers grown by MBE were employed. The simulation results revealed that the precursor of boron cluster (BI_2) is dominant at the initial stage of annealing, which explains the boron TED phenomenon in terms of the concentration of boron complexes and I, V clusters, respectively. The formation of #left brace#311#right brace# defects and dislocation loop were observed from the ...

2004-11-01

433

Ion beams in silicon processing and characterization  

Energy Technology Data Exchange (ETDEWEB)

General trends in integrated circuit technology toward smaller device dimensions, lower thermal budgets, and simplified processing steps present severe physical and engineering challenges to ion implantation. These challenges, together with the need for physically based models at exceedingly small dimensions, are leading to a new level of understanding of fundamental defect science in Si. In this article, we review the current status and future trends in ion implantation of Si at low and high energies with particular emphasis on areas where recent advances have been made and where further understanding is needed. Particularly interesting are the emerging approaches to defect and dopant distribution modeling, transient enhanced diffusion, high energy implantation and defect accumulation, and metal impurity gettering. Developments in the use of ion beams for analysis indicate much progress has been made in one-dimensional ...

1997-05-01

434

Investigation on boron transient enhanced diffusion induced by the advanced P{sup +}/N ultra-shallow junction fabrication processes  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P{sup +}/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B{sup +} and BF{sub 2}{sup +} ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF{sub 3} as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit ...

2005-08-01

435

Investigation on boron transient enhanced diffusion induced by the advanced P"+/N ultra-shallow junction fabrication processes  

International Nuclear Information System (INIS)

In this paper, we propose to characterize boron transient enhanced diffusion (TED) for processes currently used for P"+/N ultra-shallow junctions (USJ) fabrication. Indeed, the fundamental understanding of boron diffusion for low energy boron implantation is mandatory to evaluate the scalability of such processes for the coming complementary metal-oxide-semiconductor (CMOS) transistor generations. In these experiments, we characterize the boron anomalous diffusion, thanks to boron buried marker-layers obtained by epitaxial growth. B"+ and BF_2"+ ultra-low energy (ULE) implantations and plasma doping (PLAD) using BF_3 as precursor gas are carried out to compare the two techniques used for advanced USJ fabrication. Boron diffusion behaviors are analyzed via secondary ion mass spectrometry for annealing at 700 deg. C for 5 min and 15 min. Finally this paper brings some physical insights explaining the technological benefit coming from PLAD ...

2005-08-01

436

Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon  

Energy Technology Data Exchange (ETDEWEB)

Ion implantation of Si (60 keV, 1{times}10{sup 14}/cm{sup 2}) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1{times}10{sup 18} and 1{times}10{sup 19}/cm{sup 3}. Following post-implantation annealing at 740{degree}C for 15 min to allow agglomeration of the available interstitials into elongated {l_brace}311{r_brace} defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in {l_brace}311{r_brace} defects as a function of boron concentration, up to nearly complete disappearance of the {l_brace}311{r_brace} defects at boron concentrations of 1{times}10{sup 19}/cm{sup 3}. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and ...

1996-09-01

437

Interactions of ion-implantation-induced interstitials with boron at high concentrations in silicon  

International Nuclear Information System (INIS)

Ion implantation of Si (60 keV, 1x10"1"4/cm"2) has been used to introduce excess interstitials into silicon predoped with high background concentrations of B, which were varied between 1x10"1"8 and 1x10"1"9/cm"3. Following post-implantation annealing at 740 degree C for 15 min to allow agglomeration of the available interstitials into elongated #left brace#311#right brace# defects, the density of the agglomerated interstitials was determined by plan-view transmission electron microscopy observation of the defects. We report a significant reduction in the fraction of excess interstitials trapped in #left brace#311#right brace# defects as a function of boron concentration, up to nearly complete disappearance of the #left brace#311#right brace# defects at boron concentrations of 1x10"1"9/cm"3. The reduction of the excess interstitial concentration is interpreted in terms of boron-interstitial clustering, and implications for transient-enhanced ...

438

Influence of fluorine on the simulation of the transient enhanced diffusion of 15 keV BF{sub 2}{sup +} ion implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF{sub 2}{sup +}) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF{sub 2}{sup +} implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental ...

2002-01-01

439

Helium ion implantation in SiAlON: Characterisation of cavity structures using TEM and IBA  

International Nuclear Information System (INIS)

Highly swollen nanoporous layers produced in material surfaces by He implantation are of special interest for applications such as catalysis. Here we investigate whether nanoporous layers can be produced in the covalently bonded insulating ceramic, SiAlON. The retention of highly swollen porous structures in thinned TEM sections prepared from such hard brittle materials is particularly challenging. We have successfully prepared such sections both parallel to, and perpendicular to, the implanted surface. At intermediate doses the bubble structures are very similar to those found in metals. At high helium doses local swellings at depths around the mean projected range of the He ions (#approx#360 nm) are estimated to be well in excess of 200%. Bubble structures are stable under heating to temperatures up to 1200 deg. C. It is found that the highly cavitated layer is buried below a crystalline overlayer of compact SiAlON. This overlayer is ...

2000-05-02

440

Formation of stable dopant interstitials during ion implantation of silicon  

Energy Technology Data Exchange (ETDEWEB)

High concentrations of self-interstitials are trapped by dopant atoms during ion implantation into Si. For group V dopants, these complexes are sufficiently stable to survive solid-phase-epitaxial (SPE) growth but break up on subsequent thermal processing and cause a transient-enhanced diffusion. Dopant diffusion coefficients are enhanced by up to five orders of magnitude over tracer values and are characterized by an activation energy of approximately one half of the tracer values. In the case of group III dopants, any complexes formed during implantation do not survive SPE growth but a second source of self-interstitials becomes significant and leads to similar transient effects. This is the damaged layer underlying the original amorphous/crystalline interface. These observations provide direct evidence for long-range self-interstitial migration in Si, and we believe these are the first observations of the interstitialcy diffusion mechanism ...

1986-05-01

441

Formation of stable dopant interstitials during ion implantation of silicon  

International Nuclear Information System (INIS)

High concentrations of self-interstitials are trapped by dopant atoms during ion implantation into Si. For group V dopants, these complexes are sufficiently stable to survive solid-phase-epitaxial (SPE) growth but break up on subsequent thermal processing and cause a transient-enhanced diffusion. Dopant diffusion coefficients are enhanced by up to five orders of magnitude over tracer values and are characterized by an activation energy of approximately one half of the tracer values. In the case of group III dopants, any complexes formed during implantation do not survive SPE growth but a second source of self-interstitials becomes significant and leads to similar transient effects. This is the damaged layer underlying the original amorphous/crystalline interface. These observations provide direct evidence for long-range self-interstitial migration in Si, and we believe these are the first observations of the interstitialcy diffusion mechanism ...

442

Effect of hydrostatic pressure on photoluminescence spectra from structures with Si nanocrystals fabricated in SiO_2 matrix  

International Nuclear Information System (INIS)

The effect of hydrostatic pressure applied at high temperature on photoluminescence of Si-implanted SiO_2 films was studied. A 'blue'-shift of PL spectrum from the SiO_2 films implanted with Si"+ ions to total dose of 1.2x10"1"7 cm"-"2 with increase in hydrostatic pressure was observed. For the films implanted with Si"+ions to a total dose of 4.8x10"1"6 cm"-"2 high temperature annealing under high hydrostatic pressure (12 kbar) causes a 'red'-shift of photoluminescence spectrum. The 'red' photoluminescence bands are attributed to Si nanocrystals while the 'blue' ones are related to Si nanocrystals of reduced size or chains of silicon atoms or Si-Si defects. A decrease in size of Si nanocluster occurs in result of the pressure-induced decrease in the diffusion of silicon atoms. (author)

2001-09-23

443

Effect of helium implantation on the mechanical properties and the microstructure of the martensitic 12% Cr-steel 1. 4914  

Energy Technology Data Exchange (ETDEWEB)

Tensile specimens of the normalized and tempered fully martensitic steel DIN 1.4914 were helium implanted up to 340 appm within the temperature range 300-720/sup 0/C using a 104 MeV alpha particle beam. The high He/damage ratio of 1850 appm He/dpa allowed to determine the effect of helium on material properties. After irradiation tensile strength and ductility were investigated mainly at test temperatures equal to the irradiation temperatures. While short time irradiations with helium contents up to 100 appm have shown no visible effect on the tensile behaviour at all temperatures investigated, long time irradiations reduced the material strength at irradiation temperatures above about 440/sup 0/C. This irradiation induced softening obscured the predicted minor hardening effect of the observed He-bubbles completely and increases with irradiation time and temperature. The fracture mode of helium-implanted and control specimens is found to remain ...

1988-07-01

444

Defect suppression of indium end-of-range during solid phase epitaxy annealing using Si{sub 1-y}C {sub y} in silicon  

Energy Technology Data Exchange (ETDEWEB)

We report on the elimination of defect formation which is associated with high dose indium implantations under solid phase epitaxial regrowth (SPER) annealing conditions of 650-800 deg. C. This is achieved by incorporating a layer of epitaxially grown Si{sub 1-y}C {sub y} layer, strategically located at the end-of-range (EOR) of the implant profile. An indium implant of 115 keV at 1 x 10{sup 14} cm{sup -2} was performed followed by annealing at temperature ranges of 650-800 deg. C. Samples with the Si{sub 1-y}C {sub y} layer revealed the elimination of secondary EOR defects with effectively suppressed indium transient enhanced diffusion (TED), indicating the function of carbon as an efficient sink for silicon interstitials at reduced annealing temperatures, in the SPER dopant activation regime.

2006-05-10

445

Control of diffusion of implanted boron in preamorphized Si: Elimination of interstitial defects at the amorphous-crystal interface  

Energy Technology Data Exchange (ETDEWEB)

Transient-enhanced diffusion (TED) during thermal annealing of ion-implanted B in Si is well established and attributed to the ion-induced, excess interstitials. On the other hand, the mechanism to account for TED of B in preamorphized (PA) Si remains unclear. Enhanced diffusion of the B persists in regrown layers even though the ion-induced interstitial defects responsible for TED in B{sup +}-only implanted Si are eliminated following regrowth. To test the hypothesis that TED in PA Si results from the {open_quotes}excess{close_quotes} interstitial-type defects below the amorphous-crystalline (a-c) interface, a buried PA layer has been recrystallized from the surface inward to the SiO{sub 2} interface of silicon-on-insulator material to eliminate all possible sources of excess interstitials. The effect on B diffusion and the role of the residual interstitial-type defects will be discussed. {copyright} {ital 1999 American Institute of Physics.}

1999-02-01

446

A transient enhanced diffusion model of lattice restoration during rapid thermal annealing (RTA)  

International Nuclear Information System (INIS)

A transient-enhanced diffusion has been observed during the furnace or rapid thermal annealing of As-implanted Si. The relations of the enhanced diffusion to residual defects and lattice restoration have been studied in detail. The As concentration profiles and residual defects are measured. It is found from the data that the lattice has been restored when the implanted sample is annealed at 1150 deg C (or 1050 deg C) for 1s. The defect density decreases rapidly with increase of annealing time (from 1 to 12s). The enhanced diffusion coefficient maximum appears in the annealing time ranging from 1 to 5s. Allmost a 'complete' annealing of displacemet damage is obtained and the diffusion coefficient is less than that in above-mentioned conditions when the implanted samples are annealed at 1150 deg C in the time ranging from 12 to 20s. the mechanism of lattice restoration and enhanced diffusion in annealing process have been ...

447

A comparative study on ultra-shallow junction formation using co-implantation with fluorine or carbon in pre-amorphized silicon  

Energy Technology Data Exchange (ETDEWEB)

The main driver in ultra-shallow formation for the 65 nm technology node and beyond is to find solutions that both reduce boron transient enhanced diffusion and can be integrated in the CMOS process flow. To this end, many studies have recently focused on using co-doping techniques with fluorine and most recently with carbon. In most cases, one or both of these is co-implanted with a dopant specie in pre-amorphized silicon. In this work, we show a comparative study of fluorine or carbon co-implanted with low-energy boron to form source and drain extension junctions for PMOS devices. We will show that by a systematic optimization of germanium, boron, fluorine or carbon energies and doses, spike annealing technology can be extended to the 65 nm node. These results will be used to discuss how the different formed junctions offer potential solutions for either low-power or high-performance PMOS device fabrication.

2005-12-05

448

[Treatment strategies in osteochondral lesions of the talus. Review of the literature].  

Science.gov (United States)

The aim of this study was to compare the results of different treatment strategies for osteochondral defects (OCD) of the talus. Electronic databases from 1966 to June 2000 were systematically screened. Thirty-nine studies fulfilled our inclusion criteria. No randomized clinical trials could be identified. The results of nonoperative treatment were described in 14 studies, of excision alone in 4, of excision and curettage in 10, of excision, curettage and drilling in 21, of cancellous bone grafting in 2, of fixation in 3, and of osteochondral transplantation in 1. Good or excellent results were found in 45% of the cases. Comparison of different surgical procedures showed that excision, curettage and drilling resulted in the highest mean success rate (86%), followed by excision and curettage (76%) and excision alone (38%). From the results of this systematic review we conclude that nonoperative treatment and excision alone are not to be recommended for treatment of ...

2001-01-01

449

Tribological and corrosion testing of surface engineered surgical grade CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

One of the main causes of hip prostheses failure is the premature wear of its components. Wear of metal-on-metal joints is a concern due to the toxicity and biological reaction of wear debris and metallic corrosion. The main aim of the present study was to investigate the tribological and corrosion behavior of surface engineering CoCrMo alloy. Different surface conditions were obtained on surgical grade wrought CoCrMo alloy: plasma nitrided (520^oC by 7h at gas mixture of 10% N2+90% H2), PVD coated (monolayer CrN and multilayer (TiN/CrN)x3) and modified using duplex surface engineering technology (a combination of the two previous approaches: plasma nitriding followed by plasma assisted PVD). Surfaces were characterized using scanning electron microscopy, nanoindentation, AFM and scratch t...

2011-01-01

450

Surgical treatments for post-irradiation intestinal injury in uterine cervix cancer patients  

Energy Technology Data Exchange (ETDEWEB)

We examined 19 patients with post-irradiation intestinal injury in the uterine cervix cancer for 12 years between 1985 and 1996. We discuss the usefulness and complications of surgery, mainly colostomy. The patients aged from 36 to 80 (average age 61) were treated, and their disease states were 12 cases of rectovaginal fistula, 2 of small intestinal fisfula, 1 of rectum posterior membranous fistula, 3 of proctostenosis, and 14 of proctitis with hemorrhage (including duplication). Surgical methods used were 18 cases of colostomy (2 cases were treated under peritoneum mirror) and 2 of enterocolostomy (including duplication). Eleven out of 19 patients who underwent surgery are alive now. Generally the post-irradiation intestinal injury was intractable, and the method of treatments were limited due to the coexistence of various diseases. The colostomy is safe and less invasive. Therefore patients with uterine cervix cancer having various complications can obtain high ...

1997-06-01

451

Sprengel deformity in a nine-year-old boy: diagnosis and therapy; Sprengel-Deformitaet bei einem neunjaehrigen Jungen: Diagnostik und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Sprengel deformity is a congential malformation with usually unilateral elevation and medial rotation of the scapula. An omovertebral bone is generally present. Associated skeletal malformations are frequently present. Though functional impairment is mild, the cosmetic and psycho-social impairment can be considerable. The prognosis of early surgical therapy is good. The presented case also justifies surgical correction in the older child. (orig.) [German] Die Sprengel-Deformitaet ist eine angeborene Fehlbildung mit meist einseitiger Elevation und Medialrotation der Skapula. Meist ist ein Os omovertebrale vorhanden. Assoziierte skelettale Fehlbildungen sind haeufig. Obgleich funktionell wenig einschraenkend, ist die kosmetische und psycho-soziale Beeintraechtigung oft erheblich. Die Prognose der fruehen operativen Therapie ist gut. Der vorliegende Fall ermutigt zur operativen Therapie auch im hoeheren Kindesalter. (orig.)

2003-02-01

452

Radiofrequency ablation of lung and liver lesions using CT fluoroscopy  

International Nuclear Information System (INIS)

Full text: Tumour ablation with radiofrequency (RF) energy is a relatively new procedure for the treatment of focal malignant disease. At our institution this is currently being used in the treatment of certain liver and lung lesions with the patients involved being enrolled in clinical trials. The poster describes the technique used at our institution for the placement of the radiofrequency ablation electrode using CT fluoroscopy. Criteria for patient selection are included. Complications from the procedure are described, as well as follow up appearances and results. Our results from the treatment of primary and secondary lesions in the liver correlate well with published literature. Treatment is still not as successful as surgical resection but there is significantly less morbidity. Where this method may be appropriate is when the patient is not a candidate for surgical resection. The treatment of colorectal metastases in the lung shows early ...

2002-06-01

453

Proximal cholangiocarcinoma. Prognostic factor and effectiveness of post operative radiotherapy  

International Nuclear Information System (INIS)

To define the prognostic factors after surgical resection and evaluate the effectiveness of Post Operative Radiotherapy (PORT) in cases with cholangiocarcinoma, 44 cases with proximal cholangiocarcinoma were examined. The mean observation period was 20.6 months, and the survival rates 1, 3 and 5 years after the resection were 79.9%, 59.8% and 39.3%, respectively. Univariate analysis revealed that the presence of lymph node metastasis and absence of PORT were significant poor prognostic factors. Multivariate analysis revealed that the absence of PORT was a significant poor prognostic factor. The survival rates for 1 and 3 years after the resection were 80.0% and 40.0% in the curable A/B and PORT (-) group, and 100% and 53.3% in curable C and PORT (+) group. There were no local reccurences in the pathologically classified hm2 and em2 patients who underwent PORT. Even when the surgical margin is positive for the carcinoma pathologically, it is ...

2000-10-01

454

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee  

International Nuclear Information System (INIS)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight lesions in 13% to 40% of the cases. Single, combined and bland ...

455

MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings  

International Nuclear Information System (INIS)

The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver involvement in 80% of the cases. The number of ...

2008-10-01

456

Internal medical therapy of gastrointestinal stroma tumors; Internistische Therapie gastrointestinaler Stromatumoren  

Energy Technology Data Exchange (ETDEWEB)

Until recently no active treatment for advanced or metastatic gastrointestinal stroma tumors (GIST) was available. The tyrosine kinase inhibitor imatinib has revolutionized the treatment of this disease and the median overall survival now reaches 5 years. The standard dose of imatinib is 400 mg per day. Locally advanced GIST should be treated with systemic therapy prior to surgical resection. Imatinib was recently licensed for adjuvant therapy following complete surgical removal of GIST in patients with a significant risk of recurrence. (orig.) [German] Bis vor einigen Jahren existierte keine wirksame systemische Therapie fuer fortgeschrittene oder metastasierte gastrointestinale Stromatumoren (GIST). Der Tyrosinkinaseinhibitor Imatinib hat die Behandlung dieser Tumoren revolutioniert, die mediane Ueberlebenszeit liegt heute bei etwa 5 Jahren. Die Standarddosierung von Imatinib betraegt initial 400 mg/Tag. Lokal fortgeschrittene Tumoren werden ...

2009-12-15

457

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the temporal squamous epithelium to the ...

458

Evolution of virtual CT laparoscopy for preoperative imaging in laparoscopic cholecystectomy  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to determine the feasibility of virtual endoscopy, named as ''virtual CT laparoscopy'', in the hepatobiliary system prior to laparoscopic cholecystectomy. We applied this technique to 28 patients suspected of having biliary disease. These images were compared and analyzed qualitatively based on visualization of the structures critical to operative cholangiography and surgical findings. Twenty-four patients, who underwent laparoscopic cholecystectomy, were evaluated as follows: the common bile duct and the hepatic duct were adequately visualized in 23 (96%) of the 24 patients, the cystic duct in 21 (88%), the gallbladder opacification in 20 (83%), the liver inferior surface in 20 (83%). Four patients had anatomic variations detected virtual CT laparoscopy and were proven by operative cholangiography and surgical findings. We emphasize that our new technique may contribute to the ...

2002-06-01

459

Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis  

Energy Technology Data Exchange (ETDEWEB)

To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of the appendiceal wall was observed in all 29 cases of phlegmonous appendicitis ...

2001-08-01

460

Diagnosis for the cancer extension of cholangiocarcinoma. The current status  

International Nuclear Information System (INIS)

Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or middle/lower ductal, is different. MDCT-MPR and ...

2010-07-01

461

A clinical perspective on common forms of acquired heterotopic ossification  

Energy Technology Data Exchange (ETDEWEB)

The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury HO is removed at 1.5 ...

1991-02-01

462

A clinical perspective on common forms of acquired heterotopic ossification  

International Nuclear Information System (INIS)

The clinical courses of heterotopic ossification (HO) as a consequence of trauma and central nervous system insults have many similarities as well as dissimilarities. Detection is commonly noted at two months. The incidence of clinically significant HO is 10%-20%. Approximately 10% of the HO is massive and causes severe restriction in joint motion or ankylosis. The most common sign and symptom are decreased range of motion and pain. The locations are the proximal limbs and joints. Sites of HO about a joint may vary according to the etiology of the HO. Roentgenographic evolution of HO occurs during a six-month period in the majority of patients. Treatment modalities include diphosphonates, indomethacin, radiation, range of motion exercises, and surgical excision. Surgical timing differs according to etiology: traumatic HO may be resected at six months; spinal cord injury HO is excised at one year; and traumatic brain injury HO is removed at 1.5 ...

463

Evolution of surfaces properties for 100Cr6 steel by implantation and ionic mixing; Evolution des proprietes de surface de l`acier 100Cr6 par implantation et melange ioniques  

Energy Technology Data Exchange (ETDEWEB)

Physico-chemical characterizations performed on samples of 100Cr6 steel implanted both with boron and nitrogen revealed the formation of boron nitride along with the following new phases: Fe{sub 1-x}(B, N), Fe{sub 2-x}(B, N) and Fe{sub 3-x}(B, N). A thorough analysis of boron NITRIDE (5BN) indicates that a low ion current density (3 {mu}A.cm{sup -2}) in the case of the boron plus nitrogen sequence favours the formation of sp{sup 2} bonds (hexagonal-BN) while a higher ion current density (6{mu}A.cm{sup -2}) promotes sp{sup 3} bonds (cubic-BN) in the opposite sequence. Tribological tests carried out on these samples revealed that nitrogen and boron implantations do not lead to any significant improvement of friction and wear at variance with the results obtained by others authors. However, on a set samples accidentally contaminated with carbon during implantation, we noticed a considerable improvement of these tribological ...

1996-07-09

464

Value of computed Tomography in re-staging patients undergoing second-look laparotomy for ovarian cancer  

International Nuclear Information System (INIS)

Twenty-five patients with ovarian carcinoma who had been operated and treated with chemotherapy underwent clinical examination and CT before reintervention (second-look laparotomy) to detect the presence of eventual recurrences. The prediction of recurrence based on CT and clinical findings was compared with the surgical findings at reintervention. CT proved to be more accurate than clinical examination in detecting recurrences; this was especially true for masses in the abdominal cavity, with the exception of small peritoneal nodules. The authors suggest the use of CT for staging the patients candidate to reintervention. This might help to avoid reintervantion in patients with persistent disease and to plan treatment.

1991-01-01

465

The successful treatment of lupus pernio with the flashlamp pulsed dye laser.  

Science.gov (United States)

Lupus pernio of the nose is the most characteristic cutaneous lesion of sarcoidosis. It is cosmetically disfiguring and can be the cause of significant morbidity. In particular, the affected skin is often red or purple due to increased vasculature. It is particularly resistant to both surgical and medical therapy. We describe a patient with lupus pernio affecting her nose, which showed a dramatic improvement following treatment with the pulse dye laser (PDL). A biopsy taken after treatment showed the continued presence of sarcoidal granulomas. We therefore feel that treatment with the PDL is an effective tool in improving the cosmetic appearance of lupus pernio, but does not influence the underlying disease process. PMID:11360426

1999-01-01

466

Temporary endovascular control of a bleeding aortoenteric fistula by transcatheter coil embolization.  

Science.gov (United States)

A 67-year-old man presented with gastrointestinal bleeding resulting from a fistula between the aortic stump and the fourth part of the duodenum 14 months after an axillobifemoral bypass, graft excision, and aortic stump closure for aortic graft infection. The patient initially refused any attempt at definitive surgical treatment so coil embolization of the aortic stump was performed via a brachial approach. Coil embolization may be a useful adjunct in the management of such difficult problems. This approach may buy time and allow careful planning of a definitive treatment or may serve as a palliative procedure in inoperable patients. PMID:15947052

2005-06-01

467

Role of Surgery After Chemotherapy in B-Cell Lymphoma of Thymus Causing Airway Compression and Right Ventricle Outflow Tract Obstruction  

British Library Electronic Table of Contents (United Kingdom)

Primary B-cell lymphoma of thymus is uncommon. We describe the case of a 23-year-old woman with a history of shortness of breath and distended neck veins of 1-month duration. A chest roentgenogram and computed tomographic chest scan of the showed a large anterior mediastinal mass. Tru-cut biopsy revealed primary B-cell lymphoma of thymus. She underwent chemotherapy with no symptomatic improvement. Post-chemotherapy computed tomographic scan of the chest showed no appreciable reduction in tumor size. Surgical excision was carried out with excellent results.

2011-01-01

468

Cutaneous and subcutaneous Ewing's sarcoma: an indolent disease  

International Nuclear Information System (INIS)

Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy of the mass at the time of referral. They ...

2000-01-15

469

Computed tomography in the evaluation of soft tissue tumors  

International Nuclear Information System (INIS)

In order to evaluate the role of Computed Tomography (CT) in prediction of nature, staging and follow-up of soft-tessue tumors, the authors examined by CT 124 patients with soft tissue neoplasms who later underwent surgery (116 cases) or fine needle biopsy (8 cases). Comparison between CT and surgical or anatomical results showed that CT was able to correctly predict the benignancy or malignancy of the masses in 76% of cases but it was very seldom able to allow an hystological prediction. On the contrary CT was found to be a very useful tool for pre-therapeutic staging and follow-up of the tumors, because it gave many diagnostic information which influenced therapeutic choiches and strategies.

1986-01-01

470

CT-pathologic correlation of focal area of ground-glass attenuation (GGA) in the peripheral lung  

Energy Technology Data Exchange (ETDEWEB)

We compared the characteristics on thin-section CT images with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)

2001-07-01

471

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

472

A case study of trastuzumab treatment for metastatic breast cancer in pregnancy: fetal risks and management of cerebral metastases  

British Library Electronic Table of Contents (United Kingdom)

Trastuzumab increases survival amongst women with human epidermal growth factor receptor (HER)-2 receptor positive metastatic breast cancer, but maternal and fetal risks are associated with advanced disease and its treatment in pregnancy. We present a case of a primigravid with HER-2 positive metastatic breast cancer who received trastuzumab throughout pregnancy. She presented with cerebral metastases, requiring surgical decompression and resection. Reversible oligohydramnios developed during pregnancy. Fetal safety data on trastuzumab in pregnancy is limited, but case reports suggest a recurring pattern of (mostly reversible) oligohydramnios.

2011-01-01

473

Useful vacancies: Positron beam interrogation of fluorine-vacancy complexes in semiconductor device structures  

Energy Technology Data Exchange (ETDEWEB)

The formation, migration and agglomeration in silicon of fluorine-vacancy complexes have been monitored by single-detector Doppler broadening spectroscopy. After electronics engineers found that fluorine ion implantation effectively eliminated the transient-enhanced diffusion of dopants in the creation of ultra-shallow junctions, a vital step in the further miniaturization of device structures, positron beams have played a pivotal role in providing an insight into the mechanisms underlying this phenomenon, being able to detect FV complexes in implanted and annealed samples. Secondary Ion Mass Spectrometry has provided complementary information on fluorine concentrations so that the nature of the F{sub m}V{sub n} complexes can be further assessed. New results on Si and SiGe structures are presented.

2008-10-31

474

Treatment of hilar cholangiocarcinoma with inserting biliary double stents  

International Nuclear Information System (INIS)

Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 #+-# 29) #mu#mol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

2004-10-01

475

Structure and properties of stainless steels after plasma immersion ion implantation and plasma nitriding; Struktur und Eigenschaften nichtrostender Staehle nach einer Plasmaimmersionsionenimplantation und einer Plasmanitrierung  

Energy Technology Data Exchange (ETDEWEB)

Stainless steels can be nitrided at temperatures {<=}400 C to increase their hardness and wear resistance without a decreasing of their excellent corrosion resistance. Structure and properties of the surface layers produced by plasma nitriding and plasma immersion ion implantation in this temperature range were tested. There are negligible differences in the structure of the produced surface layers in spite of different interaction principles of the used technologies. However there are clear differences between the case of different steels. The case of ferritic chromium steels mainly consists of {epsilon}-nitride. Whereas the cases of austenitic and ferritic austenitic steels are characterized by expanded austenite. The corrosion resistance of the steels is reduced by nitriding only, if evident CrN-formation occurs. (orig.) 11 refs.

1999-08-01

476

Structure and Optical Properties of Silicon Layers with GaSb Nanocrystals Created by Ion-Beam Synthesis  

International Nuclear Information System (INIS)

We have studied the ion-beam synthesis of GaSb nanocrystals in Si by high-fluence '' hot '' implantation of Sb and Ga ions followed by thermal annealing. The Rutherford backscattering, transmission electron microscopy/transmission electron diffraction, Raman spectroscopy and photoluminescence were used to characterize the implanted layers. It was found that the nanocrystal size increases from 5 to 60 nm in the samples annealed at 900"oC up to 20-90 nm in those annealed at 1100"oC. For the samples annealed at 900"oC a broad band in the region of 0.75-1.05 eV is registered in the photoluminescence spectra. The nature of this photoluminescence band is discussed. (author)

2011-07-01

477

Silicon oxide conductivity of hydrogen ion implanted polysilicon thin film transistors  

Energy Technology Data Exchange (ETDEWEB)

The influence of hydrogen ion implantation into the channel polysilicon of polysilicon thin film transistors on gate oxide conductivity has been investigated. Data for effective tunnelling barriers at the gate oxide/channel polysilicon interface are presented. A value of 1.2eV for samples with boron doped channel polysilicon is calculated. For hydrogenated boron doped samples tunnelling barriers higher than 2.1 eV are obtained. The tunnelling barriers for phosphorus doped samples are impurity concentration dependent and decrease with increasing phosphorus concentration in the range 3 x 10{sup 17} to 3 x 10{sup 19} cm{sup -3}. (Author).

1996-10-01

478

Silicon oxide conductivity of hydrogen ion implanted polysilicon thin film transistors  

International Nuclear Information System (INIS)

The influence of hydrogen ion implantation into the channel polysilicon of polysilicon thin film transistors on gate oxide conductivity has been investigated. Data for effective tunnelling barriers at the gate oxide/channel polysilicon interface are presented. A value of 1.2eV for samples with boron doped channel polysilicon is calculated. For hydrogenated boron doped samples tunnelling barriers higher than 2.1 eV are obtained. The tunnelling barriers for phosphorus doped samples are impurity concentration dependent and decrease with increasing phosphorus concentration in the range 3 x 10"1"7 to 3 x 10"1"9 cm"-"3. (Author).

479

Raney-platinum film electrodes for potentially implantable glucose fuel cells. Part 2: Glucose-tolerant oxygen reduction cathodes  

British Library Electronic Table of Contents (United Kingdom)

We report the fabrication and characterization of glucose-tolerant Raney-platinum cathodes for oxygen reduction in potentially implantable glucose fuel. Fabricated by extraction of aluminum from 1mm thin platinum-aluminum bi-layers annealed at 300^oC, the novel cathodes show excellent resistance against hydrolytic and oxidative attack. This renders them superior over previous cathodes fabricated from hydrogel-bound catalyst particles. Annealing times of 60, 120, and 240min result in approximately 400-550nm thin porous films (roughness factors ~100-150), which contain platinum and aluminum in a ratio of ~9:1. Aluminum release during electrode operation can be expected to have no significant effect on physiological normal levels, which promises good biocompatibility. Annealing time has a dis...

2010-01-01

480

Raney-platinum film electrodes for potentially implantable glucose fuel cells. Part 1: Nickel-free glucose oxidation anodes  

British Library Electronic Table of Contents (United Kingdom)

We present a novel fabrication route yielding Raney-platinum film electrodes intended as glucose oxidation anodes for potentially implantable fuel cells. Fabrication roots on thermal alloying of an extractable metal with bulk platinum at 200^oC for 48h. In contrast to earlier works using carcinogenic nickel, we employ zinc as potentially biocompatible alloying partner. Microstructure analysis indicates that after removal of extractable zinc the porous Raney-platinum film (roughness factor ~2700) consists predominantly of the Pt3Zn phase. Release of zinc during electrode operation can be expected to have no significant effect on physiological normal levels in blood and serum, which promises good biocompatibility. In contrast to previous anodes based on hydrogel-bound catalyst particles the ...

2010-01-01

481

Optimizing boron junctions through point defect and stress engineering using carbon and germanium co-implants  

International Nuclear Information System (INIS)

We report the fabrication of p"+/n junctions using Ge"+, C"+, and B"+ co-implantation and a spike anneal. The best junction exhibits a depth of 26 nm, vertical abruptness of 3 nm/decade, and sheet resistance of 520 Ohm/square. The junction location is defined by where the boron concentration drops to 10"1"8 cm"-"3. These junctions are close to the International Technology Roadmap specifications for the 65 nm technology node and are achieved by careful engineering of amorphization, stresses, and point defects. Advanced simulation of boron diffusion is used to understand and optimize the process window. The simulations show that the optimum process completely suppresses the transient-enhanced diffusion of boron and the formation of boron-interstitial clusters. This increases the boron solubility to 20% above the equilibrium solid-state solubility.

2005-08-01

482

Optimized pre-amorphization conditions for the formation of highly activated ultra shallow junctions in silicon-on insulator  

International Nuclear Information System (INIS)

Pre-amorphization of ultrashallow implanted boron in Silicon-on-insulator is optimized to produce an abrupt box-like doping profile with negligible electrical deactivation and significantly reduced transient enhanced diffusion. The effect is achieved by positioning the as-implanted amorphous/crystalline interface close to the buried oxide interface, to minimize interstitials whilst leaving a single-crystal seed to support solid-phase epitaxy. Based on a simple physical model of our results, we estimate that the interface between the Si overlayer and the buried oxide is an efficient interstitial sink with a recombination length of the order of 10nm or less under our experimental conditions. (author)

2008-12-01

483

Modeling of phosphorus diffusion in Ge accounting for a cubic dependence of the diffusivity with the electron concentration  

International Nuclear Information System (INIS)

Up to now, P diffusion in Ge is modeled with an effective diffusivity involving at most a quadratic dependence with the free electron concentration (n). However, recent theoretical studies suggest the existence of a triply negatively charged state for the free vacancy in germanium and experimental data indicate that the E center (PV pair) in Ge has a double acceptor state. These two facts would be consistent with a diffusivity model involving a cubic dependence with n. In this paper the validity of this approach is checked for both pure thermal diffusion (intrinsic and extrinsic) and implanted phosphorus, using either our own experiments or other data available from the literature. Although some discrepancies still exist in some cases for the redistribution of implanted P, it is shown that the introduction of this cubic dependence significantly improves the overall agreement as compared with the usual model.

2010-02-26

484

Linearized augmented-plane-wave method for quasi-unidimensional systems: Carbyne and nanotube (Sc@C{sub 20})  

Energy Technology Data Exchange (ETDEWEB)

The advent of carbon nanotubes, which are graphite layers convoluted in cylinders several nanometers in diameter and several micrometers in length, as well as the experiments on implanting metal atoms in such tubes open the way to producing nanoconductors and other materials with unique properties. For theorists, the basic challenge is interpreting and predicting the structure and properties of these systems. The linearized augmented-plane-wave method (LAPW) is one of the most accurate methods in the theory of the electronic structure of solids. A generalization of this method for quasi-two-dimensional systems, surface electronic states, and layered crystals is known. The LAPW theory for quasi-unidimensional systems, which exhibit translational symmetry in one direction, has been absent thus far. In this paper, the authors suggest a version of such a theory and use this method to calculate the electronic structure of carbyne (a linear chain of carbon atoms) and ...

1995-10-01

485

Information-seeking behaviour and coping style of women opting for either implant or DIEP-flap breast reconstruction  

British Library Electronic Table of Contents (United Kingdom)

Background: High satisfaction rates have been reported after autologous breast reconstruction. Yet, most mastectomy patients receive implant reconstructions (ImBR). Independent and active decision makers have shown mainly to choose for autologous reconstructions, such as the Deep inferior epigastric perforator (DIEP) flap (DiepBR). To further explore the decision making to opt for either ImBR or DiepBR, we investigated patient knowledge, informational resources used, effect of plastic surgeons' advice, coping style and personal independence. Methods: A total of 153 women, who were planned for DiepBR or ImBR preoperatively, completed a study-specific and standardised validated psychological questionnaire. Analyses were aimed at information-seeking behaviour, personal independence and coping...

2011-01-01

486

Hydroxyapatite coating enhances polyethylene terephthalate artificial ligament graft osseointegration in the bone tunnel  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to investigate whether hydroxyapatite (HAp) coating could induce polyethylene terephthalate (PET) artificial ligament graft osseointegration in the bone tunnel. Twenty-four New Zealand white rabbits underwent artificial ligament graft transplantation in bilateral proximal tibia tunnels. One limb was implanted with HAp-coated PET graft, and the contralateral limb was implanted with non-HAp-coated PET graft as control. The rabbits were randomly sacrificed at four and eight?weeks after surgery. The loads to failure of the experimental group at eight?weeks were significantly higher than those of the control group (p?=?0.0057). Histologically, application of HAp coating induced new bone formation between graft and bone at eight?weeks compared with the controls. Rea...

2011-01-01

487

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

488

Growth meachnisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films  

Energy Technology Data Exchange (ETDEWEB)

Growth mechanisms and thermal stability of ion-beam-induced epitaxial Pd/sub 2/Si films are investigated using Rutherford backscattering and channelling techniques. Epitaxial growth of Pd/sub 2/Si films was observed at room temperature by argon ion implantation into as-deposited Pd/Si(111) structures and furnace-annealed Pd/sub 2/Si(polycrystalline)/Pd/sub 2/Si(epitaxial)/Si(111) structures. Some additional experiments to check the growth mechanisms are also presented, in which the implantation energies, substrate orientations and dose rates were changed. Finally, the stability of the ion-beam-induced epitaxial Pd/sub 2/Si films on subsequent furnace annealing is studied.

1982-06-11

489

Enhanced diffusion from interstitial trapping during solid-phase-epitaxial growth of silicon alloys. Draft  

Energy Technology Data Exchange (ETDEWEB)

During the recrystallization by solid-phase-epitaxial (SPE) growth of supersaturated silicon alloys, a high concentration of interstitials is trapped. These are released by subsequent heating causing a transient (greatly enhanced) diffusion of the substitutional dopant by an interstitialcy mechanism. The enhancement may be as much as five orders of magnitude over tracer values, and shows an activation energy of only 1.8 +- 0.2 eV. Following the transient, the interstitials condense into loops, allowing an independent estimate to be made of their concentration. From these observations, we propose that during ion implantation, a fraction of the implanted dopants can acquire their natural valency, and retain it as the crystallization interface passes. For group V dopants this creates the trapped interstitials, giving transient enhanced diffusion when they are released by subsequent annealing.

1984-08-01

490

Enhanced diffusion from interstitial trapping during solid-phase-epitaxial growth of silicon alloys  

Energy Technology Data Exchange (ETDEWEB)

During the recrystallization by solid-phase-expitaxial (SPE) growth of supersaturated silicon alloys, a high concentration of interstitials is trapped. These are released by subsequent heating causing a transient (greatly enhanced) diffusion of the substitutional dopant by an interstitialcy mechanism. The enhancement may be as much as five orders of magnitude over tracer values, and shows an activation energy of only 1.8 +/- 0.2 eV. Following the transient, the interstitials condense into loops, allowing an independent estimate to be made of their concentration. From these observations, it is proposed that during ion implantation, a fraction of the implanted dopants can acquire their natural valency, and retain it as the crystallization interface passes. For group V dopants this creates the trapped interstitials, giving transient enhanced diffusion when they are released by subsequent annealing. 12 references, 6 figures.

1984-01-01

491

Energetic ion beams in semiconductor processing: Summary of a DOE panel study  

Energy Technology Data Exchange (ETDEWEB)

The trend toward smaller dimensions in integrated circuit technology presents severe physical and engineering challenges for ion implantation. These challenges, together with the need for physically-based models at exceedingly small dimensions, are leading to a new level of understanding of fundamental defect science in silicon. Recently the DOE Council on Materials requested that our panel examine the current status and future research opportunities in the area of ion beams in semiconductor processing. Particularly interesting are the emerging approaches to defect and dopant distribution modeling, transient enhanced diffusion, high energy implantation and defect accumulation, and metal impurity gettering. These topics were explored both from the perspective of emerging science issues and technology challenges.

1995-12-31

492

Determination of the helium thermal diffusion coefficient in britholite using a NRA method: new results  

International Nuclear Information System (INIS)

Dimensioning of actinides waste packages for long duration storage has to take into account helium production from natural decay and release rates from the material. For the latter, we propose here an improved method for the determination of the helium diffusion coefficient in britholite, to be used for minor actinides storage. This work is based on results we previously published using the classical three steps method: "3He implantation on a Van de Graaff facility, "3He profile determination analysing the protons resulting from the "3He(d,p)"4He reaction in a nuclear microprobe, evolution of the helium profile during annealings. Taking explicitly into account the incident deuterons energy stragglings allows us to show that the implanted helium profiles are bimodal, each component leading to a different helium diffusion coefficient.

2005-02-01

493

DBR laser with nondynamic plasma grating formed by focused ion beam implanted dopants  

Energy Technology Data Exchange (ETDEWEB)

A static plasma grating has been demonstrated experimentally in a large optical cavity FIB-DBR GaAlAs/GaAs laser diode. The grating is formed by implanting stripes of dopants with a focused ion beam (FIB). The dopants ionize to form periodic fluctuations in the carrier concentration which, through the Kramers-Kronig relations, form an index grating. A model of the grating strength for optimization of the laser design is developed and presented here. The computed results show that /kappa/ can be increased by more than an order of magnitude over the 15 cm/sup -1/ experimentally. Therefore, FIB-DBR (or -DFB) lasers with performance comparable to that of conventional DBR (or DFB) lasers can be expected.

1989-06-01

494

DBR laser with nondynamic plasma grating formed by focused ion beam implanted dopants  

International Nuclear Information System (INIS)

A static plasma grating has been demonstrated experimentally in a large optical cavity FIB-DBR GaAlAs/GaAs laser diode. The grating is formed by implanting stripes of dopants with a focused ion beam (FIB). The dopants ionize to form periodic fluctuations in the carrier concentration which, through the Kramers-Kronig relations, form an index grating. A model of the grating strength for optimization of the laser design is developed and presented here. The computed results show that #kappa# can be increased by more than an order of magnitude over the 15 cm"-"1 experimentally. Therefore, FIB-DBR (or -DFB) lasers with performance comparable to that of conventional DBR (or DFB) lasers can be expected.

495

Cardiac Pacing: Memories of a Bygone Era  

British Library Electronic Table of Contents (United Kingdom)

The first cardiac pacemaker implants occurred in the late 1950s and involved insertion of epicardial or epimyocardial leads and abdominal pulse generators. By the mid 1960s, cardiologists were making attempts to insert transvenous leads into the right ventricle. These early unipolar leads had large, polished, high polarization electrodes, no fixation device, and no lumen in which to place a stylet for lead positioning. The lead implantation procedures were usually long and the irradiation to both patient and operator excessive. Pulse generators were powered by zinc-mercury cells, which were large, unreliable, and prone to sudden output failure. Postoperative complications such as lead dislodgement, exit block, and premature power source failure were very common with most patients requiring...

2008-01-01

496

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

Energy Technology Data Exchange (ETDEWEB)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of {approximately}2E13cm{sup {minus}2}. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

1995-12-31

497

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

International Nuclear Information System (INIS)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of #approx#2E13cm"-"2. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

498

Biological effects and physical safety aspects of NMR imaging and in vivo spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An assessment is made of the biological effects and physical hazards of static and time-varying fields associated with the NMR devices that are being used for clinical imaging and in vivo spectroscopy. A summary is given of the current state of knowledge concerning the mechanisms of interaction and the bioeffects of these fields. Additional topics that are discussed include: (1) physical effects on pacemakers and metallic implants such as aneurysm clips, (2) human health studies related to the effects of exposure to nonionizing electromagnetic radiation, and (3) extant guidelines for limiting exposure of patients and medical personnel to the fields produced by NMR devices. On the basis of information available at the present time, it is concluded that the fields associated with the current generation of NMR devices do not pose a significant health risk in themselves. However, rigorous guidelines must be followed to avoid the physical interaction of these fields ...

1985-08-01

499

Atomic scale simulations of arsenic ion implantation and annealing in silicon  

International Nuclear Information System (INIS)

We present results of multiple-time-scale simulations of 5, 10 and 15 keV low temperature ion implantation of arsenic on silicon (100), followed by high temperature anneals. The simulations start with a molecular dynamics (MD) calculation of the primary state of damage after 10ps. The results are then coupled to a kinetic Monte Carlo (MC) simulation of bulk defect diffusion and clustering. Dose accumulation is achieved considering that at low temperatures the damage produced in the lattice is stable. After the desired dose is accumulated, the system is annealed at 800 degrees C for several seconds. The results provide information on the evolution for the damage microstructure over macroscopic length and time scales and affords direct comparison to experimental results. We discuss the database of inputs to the MC model and how it affects the diffusion process.

2004-12-15

500

A novel EPROM device fabricated using focused boron ion-beam implantation  

Energy Technology Data Exchange (ETDEWEB)

A novel floating-gate avalanche injection (FAMOS) type erasable programmable read-only memory (EPROM) device is demonstrated, with a heavily focused ion-beam (FIB) implanted region of about 0.2-..mu..m width at the drain edge of the channel. This heavily B/sup +/-doped region permits a higher electric field near the drain edge, resulting in a remarkable increase of the hot-carrier generation rate, and reduces both the programming voltage and programming time. A three-dimensional device simulator, CADDETH, predicted that the electric field at the drain edge would increase by about six times, which would lead to hot-carrier generation efficiency three orders of magnitude higher.

1987-06-01