WorldWideScience

Sample records for sagittal tape-symphysis pubis

  1. Acute Osteomyelitis of the Symphysis Pubis after Inguinal Hernia Surgery

    Directory of Open Access Journals (Sweden)

    Recep Tekin

    2015-01-01

    Full Text Available Osteomyelitis of pubic symphysis is infectious inflammatory condition of the symphysis pubis and rare complication of surgery around inguinal and groin region. It should be kept in mind in the differential diagnosis of lower pelvic pain and should be sought in cases of pelvic insufficiency fractures. Herein, we present a case of a 55-year-old man with osteomyelitis of the symphysis pubis following inguinal hernia surgery for diagnosis and management of this rare condition.

  2. Intrapartum Pubic Symphysis Disruption

    African Journals Online (AJOL)

    Dhar S, Anderton JM. Rupture of the symphysis pubis during labor. Clin Orthop Relat Res 1992;283:252‑7. 6. Putschar WG. The structure of the human symphysis pubis with special consideration of parturition and its sequelae. Am. J Phys Anthropol 1976;45 (3 pt 2):589‑94. 7. Kharrazi FD, Rodgers WB, Kennedy JG, Lhowe ...

  3. Arthroscopic pubic symphysis debridement and adductor enthesis repair in athletes with athletic pubalgia: technical note and video illustration.

    Science.gov (United States)

    Hopp, Sascha; Tumin, Masjudin; Wilhelm, Peter; Pohlemann, Tim; Kelm, Jens

    2014-11-01

    We elaborately describe our novel arthroscopic technique of the symphysis pubis in athletes with osteitis pubis and concomitant adductor enthesopathy who fail to conservative treatment modalities. The symphysis pubis is debrided arthroscopically and the degenerated origin of adductor tendon (enthesis) is excised and reattached. With our surgical procedure the stability of the symphysis pubis is successfully preserved and the adductor longus enthesopathy simultaneously addressed in the same setting.

  4. Artritis séptica del pubis en dos deportistas Septic arthritis of the pubic symphysis in two athletes

    Directory of Open Access Journals (Sweden)

    José A. Andrews

    2012-06-01

    Full Text Available La artritis séptica de pubis u osteomielitis púbica es la infección que compromete la sínfisis pubiana y su articulación. Es poco frecuente, representando menos del 1% de las osteomielitis. Afecta más a menudo a atletas jóvenes y a mujeres que se someten a cirugía ginecológica o urológica. Se presenta con fiebre y dolor púbico, irradiado a genitales, que aumenta con la movilización de la cadera lo que produce claudicación de la marcha. Debe hacerse el diagnóstico diferencial con la osteítis del pubis que es una condición inflamatoria estéril. La punción guiada por imagen suele ser necesaria para el diagnóstico diferencial con la osteítis del pubis. El diagnóstico se basa en la clínica apoyada en el aislamiento microbiológico, métodos por imágenes e incremento de las proteínas de fase aguda. Los agentes etiológicos más comúnmente encontrados son Staphylococcus aureus, seguidos de bacilos gram negativos, o pueden ser polimicrobianos en posquirúrgicos. El tratamiento antibiótico se ajusta al germen aislado por cultivo, además de antiinflamatorios y reposo. El desbridamiento quirúrgico se requiere hasta en el 55% de los casos. Se recomiendan antibióticos por 6 semanas. Se presentan dos casos de osteomielitis del pubis por S. aureus, con buena respuesta al tratamiento. Ambos pacientes eran jóvenes y deportistas.Septic arthritis of the pubic symphysis, so called osteomyelitis pubis is the infection which involves pubic symphysis and its joint. It is a rare condition, representing less than one percent of all cases of osteomyelitis. It affects most frequently young athletes and women undergoing gynecologic or urologic surgery. It presents itself with fever and pubic pain which irradiates to the genitals and increases when hip is mobilized, and this fact produces gait claudication. Differential diagnosis should be made with pubic osteitis, which is a sterile inflammatory condition. Diagnosis is based on clinic

  5. Osteitis pubis ameliorated after tooth extraction: a case report.

    Science.gov (United States)

    Fukushi, Jun-ichi; Nakashima, Yasuharu; Iwamoto, Yukihide

    2013-03-01

    Osteitis pubis is a non-infective inflammation of the symphysis pubis, which is known to be associated with trauma, athletic exertion, urological or gynecological surgery, or with rheumatic conditions such as seronegative spondyloarthropathies. In this report, we describe a case of osteitis pubis whose symptoms were completely ameliorated following tooth extraction attributable to periodontitis. A 57-year-old female patient developed osteitis pubis, presenting with pain in the groin area with an elevated Creactive protein (CRP; 4.4 mg/dl) and radiological erosive changes in symphysis pubis. Prednisolone (5 mg/day) and etodolac were prescribed, but the patient's symptoms improved only partially and remained persistent. One year from the patient's first visit, three teeth were extracted due to severe chronic periodontitis, which she had been suffering from for years. Soon after the above tooth extraction, her symptoms appeared completely resolved, and the patient's CRP was decreased to nearly normal levels in 4 weeks. Human leukocyte antigen (HLA)-typing analysis revealed a positive result for HLA-A11, A24, and B54. Because HLA-B54 cross-reacts with HLA-B27, the patient's osteitis pubis was considered to be a form of reactive arthritis associated with periodontitis.

  6. Report of two cases of tuberculosis of pubis

    Energy Technology Data Exchange (ETDEWEB)

    Jung, L W; Jeon, B H; Kim, B S [Busan National University College of Medicine, Busan (Korea, Republic of)

    1972-12-15

    Two cases of the tuberculosis of pubis were reported which confirmed by the x-ray and microscopic findings, a case was 12 years old boy, and the other was 13 years old boy, who complained tenderness and moderate swelling over the symphysis pubis region, slight limping gait, and local redness and hotness. Their family histories were not contributory. The x-ray findings of the chest showed the old hilar lymphadenopathy with almost fibroconsolidated patterns, and the pelvis showed the destructions of the pubis with sequestrums and hazy shadows around the pubis, but no evidence of any productive bony changes. The operation was done, and the specimen showed the edematous connective tissues infiltrated with chronic inflammatory cells and granulomatas, which were composed of the epitheloid cells, macrophages, fibroblasts and small round cells.

  7. Endoscopic Pubic Symphysectomy for Athletic Osteitis Pubis.

    Science.gov (United States)

    Matsuda, Dean K; Sehgal, Bantoo; Matsuda, Nicole A

    2015-06-01

    Osteitis pubis is a common form of athletic pubalgia associated with femoroacetabular impingement. Endoscopic pubic symphysectomy was developed as a less invasive option than open surgical curettage for recalcitrant osteitis pubis. This technical note demonstrates the use of the anterior and suprapubic portals in the supine lithotomy position for endoscopic burr resection of pubic symphyseal fibrocartilage and hyaline endplates. Key steps include use of the suprapubic portal for burr resection of the posteroinferior symphysis and preservation of the posterior and arcuate ligaments. Endoscopic pubic symphysectomy is a minimally invasive bone-conserving surgery that retains stability and may be useful in the treatment of recalcitrant osteitis pubis or osteoarthritis. It nicely complements arthroscopic surgery for femoroacetabular impingement and may find broader application in this group of co-affected athletes.

  8. Imaging assessment of osteitis pubis; Avaliacao por imagem da osteite pubica

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Alexia Abuhid; Ferreira, Ana Paula Alves; Leite, Ana Rachel Albuquerque de Moura; Guido, Daniela Araujo; Rodrigues, Rogeria Nobre [Axial Centro de Imagem, Belo Horizonte, MG (Brazil)]. E-mail: ce@cidbh.com.br; Araujo, Rodrigo Otavio Dias [Minas Tenis Clube, Belo Horizonte, MG (Brazil); Lasmar, Rodrigo Campos Pace [Faculdade de Ciencias Medicas de Minas Gerais, Belo Horizonte, MG (Brazil). Curso de Fisioterapia

    2005-10-15

    Objective: to assess the physiopathological aspects of osteitis pubis and the findings seen on imaging methods, emphasizing the usefulness of Flamingo view radiographs and the diagnostic aspects of Magnetic resonance images. Material and Method: magnetic resonance images of ten patients (eight of them professional athletes) referring symptoms in the inguinal regional were retrospectively evaluated. For some of these patients Flaming view radiographs were performed. Results: in all studied patients magnetic resonance imaging was the only diagnostic method capable of showing the different phases os osteitis pubis, from acute cases with pubic bone marrow edematous changes to chronic cases with involvement of other pelvic joints. Flamingo view radiographs were performed in six patients and three of them were diagnosed with vertical pubis symphyseal instability greater than 2 mm of vertical displacement. This diagnosis was confirmed by instability tests using orthopedic manoeuvres. Conclusion: magnetic resonance imaging was the most helpful method for the diagnosis of different phases of osteitis pubis whereas conventional X-ray was inconclusive in the initial phases. Flamingo view radiographs were extremely important to show vertical instability of the pubic symphysis, which in combination with osteitis pubis can be the cause of failure of nonoperative treatment. (author)

  9. Management of chronic symphysis pubis pain following child birth with spinal cord stimulator.

    LENUS (Irish Health Repository)

    Idrees, Ahsan

    2012-01-01

    The case of a 39 year old woman who had diastasis of pubic symphysis following childbirth and later developed severe chronic neuropathic pain and disability is presented. She received extensive surgical and medical treatment for 6 years with no improvement of symptoms. The VNRS (Visual Numerical Rating Scale) pain score was 7\\/10 or more most of the time. This was quite disabling in terms of her quality of life. A spinal cord stimulator was inserted after failure of other modalities of pain management which resulted in dramatic improvement in the quality of life measured with SF-36 questionnaire. Her pain score became 0\\/10 VNRS and she was free from opioids and psychotropic medications within 3 months post insertion. Spinal cord stimulator can be considered for the management of pain due to diastasis of pubic symphysis, not amenable to other therapies.

  10. COMPARATIVE STUDY BETWEEN THE PUBIS OF ASYMPTOMATIC ATHLETES AND NON-ATHLETES WITH MRI.

    Science.gov (United States)

    Branco, Rodrigo Castelo; da Costa Fontenelle, César Rubens; Miranda, Leandro Marques; Junior, Yonder Archanjo Ching San; Vianna, Evandro Miguelote

    2010-01-01

    To compare the magnetic resonance imaging findings from the pubis of professional soccer players without any history or clinical findings of groin pain, and from sedentary individuals, also without symptoms, and to determine the prevalence of changes compatible with pubic overload. Nineteen professional soccer players without complaints of groin pain and seventeen sedentary individuals, also asymptomatic, underwent magnetic resonance imaging of the pubis. The results from the examinations were analyzed regarding the presence of degenerative changes, boned medullary edema and tendinopathy, and the two study groups were compared. High prevalence of bone edema, tendinopathy and degenerative findings in the pubic symphysis was seen in the athletes, with statistically significant higher odds ratios and relative risk in the population studied. Professional soccer players are at a higher risk of developing changes in the pubic region, shown in magnetic resonance images, compared with sedentary individuals. These findings are not necessarily caused by groin pain, and are probably related to intense exertion.

  11. Pediculosis pubis

    Directory of Open Access Journals (Sweden)

    Chang Patricia

    2011-07-01

    Full Text Available We report a male patient of 24 years old with itching at groin and pubis. Pubic hair test showed the presence of lices (fig.2-4.Pediculosis is an infestation of man and animals by insects Anoplura (Lice Vampire ectoparasites. It´s important poor hygiene, promiscuity, fomites, sexual transmission. Etiology: Pediculus humanus capitis, Human Pediculus corporis, Phthirus pubis or pubic lice. Clinically pediculosis can be classify in :head lice, body lice, pubic pediculosis. Phthirus pubis or crab lice is the agent of pediculus pubis, the sites affected are pubic region other sites as thighs, trunk, armpit, eyebrows, eyelashes, beard and scalp. Pruritus hematic crusts, excoriations, stains 0.5 cm -1 blue cerulean spots may be associated with other STD. The diagnosis is based in the clinical aspect and observes the parasite. Phthirus short pubis or pubic lice parasite, it´s size: 0.8-1.2 mm his first legs resemble those of a crab with sucking, slow walking 10 cm / min. Treatment is based on head lice or nits destruction benzyl benzoate 25% 8 to 12 hrs once, crotramiton 10% 1 / day x 8 days and ivermectin 200 micrograms / kg in a single dose.

  12. Usefulness of perineal ultrasonography after tension-free vaginal tape procedure for stress urinary incontinence

    International Nuclear Information System (INIS)

    Yoon, Seong Kuk

    2005-01-01

    To evaluate the usefulness of perineal ultrasonography after a tension-free vaginal tape (TVT) procedure in women with stress urinary incontinence. Thirty-four patients with stress urinary incontinence who underwent the TVT procedure were included in this study. We compared the perineal ultrasonography findings before and after the procedure. The mean age was 49 years (rang: 32-75 years) and the mean follow-up time was 9.5 days (range: 5-19 days). We obtained the entire sagittal image of the bladder neck, urethra, urethrovesical junction and symphysis pubis. The posterior urethrovesical angle (PUVA) and descent of the bladder neck at rest and during stress, and the diameter of proximal urethra at rest were all evaluated. We compared these ultrasonographic changes before and after the procedure. Before the TVT procedure, the PUVA was 134.7 ± 5.9 .deg. at rest and 146.8 ± 8.5 .deg. during stress, and the difference between PUVA at rest and during stress was 12.2 ± 7.3 .deg. . After the TVT procedure, the PUVA significantly decreased to 125.6 ± 7.5 .deg. at rest and 132.5 ± 8.3 .deg. during stress, and the difference also significantly decreased to 7.0 ± 5.0 .deg. (ρ < 0.01). Before the procedure, the descent of the bladder neck was 17 ± 7.0 mm, while the descent significantly decreased to 7.7 ± 4.1 mm after the procedure (ρ < 0.01). Before the procedure, the diameter of the proximal urethra was 5.6 ± 1.4 mm at rest, but the diameter was 5.5 ± 1.1 mm, without significant change, after the procedure. Follow-up perineal ultrasonography after the TVT procedure may be useful for evaluating changes including the PUVA, descent and appearance of the bladder neck

  13. Usefulness of perineal ultrasonography after tension-free vaginal tape procedure for stress urinary incontinence

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seong Kuk [Donga University College of Medicine, Busan (Korea, Republic of)

    2005-07-15

    To evaluate the usefulness of perineal ultrasonography after a tension-free vaginal tape (TVT) procedure in women with stress urinary incontinence. Thirty-four patients with stress urinary incontinence who underwent the TVT procedure were included in this study. We compared the perineal ultrasonography findings before and after the procedure. The mean age was 49 years (rang: 32-75 years) and the mean follow-up time was 9.5 days (range: 5-19 days). We obtained the entire sagittal image of the bladder neck, urethra, urethrovesical junction and symphysis pubis. The posterior urethrovesical angle (PUVA) and descent of the bladder neck at rest and during stress, and the diameter of proximal urethra at rest were all evaluated. We compared these ultrasonographic changes before and after the procedure. Before the TVT procedure, the PUVA was 134.7 {+-} 5.9 .deg. at rest and 146.8 {+-} 8.5 .deg. during stress, and the difference between PUVA at rest and during stress was 12.2 {+-} 7.3 .deg. . After the TVT procedure, the PUVA significantly decreased to 125.6 {+-} 7.5 .deg. at rest and 132.5 {+-} 8.3 .deg. during stress, and the difference also significantly decreased to 7.0 {+-} 5.0 .deg. ({rho} < 0.01). Before the procedure, the descent of the bladder neck was 17 {+-} 7.0 mm, while the descent significantly decreased to 7.7 {+-} 4.1 mm after the procedure ({rho} < 0.01). Before the procedure, the diameter of the proximal urethra was 5.6 {+-} 1.4 mm at rest, but the diameter was 5.5 {+-} 1.1 mm, without significant change, after the procedure. Follow-up perineal ultrasonography after the TVT procedure may be useful for evaluating changes including the PUVA, descent and appearance of the bladder neck.

  14. Artritis séptica del pubis en dos deportistas Septic arthritis of the pubic symphysis in two athletes

    OpenAIRE

    José A. Andrews; Daniel Rizzato Lede; Melisa Senderovsky; Bárbara C. Finn; Nicholas Emery; Federico Bottaro; Julio E. Bruetman; Pablo Young

    2012-01-01

    La artritis séptica de pubis u osteomielitis púbica es la infección que compromete la sínfisis pubiana y su articulación. Es poco frecuente, representando menos del 1% de las osteomielitis. Afecta más a menudo a atletas jóvenes y a mujeres que se someten a cirugía ginecológica o urológica. Se presenta con fiebre y dolor púbico, irradiado a genitales, que aumenta con la movilización de la cadera lo que produce claudicación de la marcha. Debe hacerse el diagnóstico diferencial con la osteítis d...

  15. Maailma esimene täispuhutav pubi

    Index Scriptorium Estoniae

    2007-01-01

    Briti firma Airquee Ltd on toonud turule maailma esimese täispuhutava pubi. Põrandapinda on selles PVC-st valmistatud hoones üle 80 m2, hoone on 7 metrit kõrge. Pubi on projekteerinud waleslane Andi Francis. Ill.: värv. välisvaade

  16. Presence of Inguinal Hernia in Soccer Players with Osteitis Pubis

    Directory of Open Access Journals (Sweden)

    Ali Eraslan

    2017-11-01

    Conclusion: The study revealed that soccer players with osteitis pubis may have concomitant inguinal hernia, and that osteitis pubis may develop in soccer players who have undergone hernia repair. In addition, more severe osteitis pubis findings on the same side with hernia indicate that the two pathologies occur with common mechanisms. It should not be forgotten that inguinal hernia be considered in the differential diagnosis of osteitis pubis, which it may accompany. Conservative methods are mostly used in the treatment of osteitis pubis, whereas the treatment of inguinal hernia is surgery. If only one entity is diagnosed when both are present, the success of treatment will decrease.

  17. Evaluation of symphysis pubis and sacroiliac joint distances in skeletally immature patients: A computerized tomography study of 1020 individuals.

    Science.gov (United States)

    Kalenderer, Önder; Turgut, Ali; Bacaksız, Tayfun; Bilgin, Emre; Kumbaracı, Mert; Akkan, Hasan Ali

    2017-03-01

    The aim of this study was to create a reference about normal pubic symphysis and sacroiliac joint widths of children and adolescents. A total of 1020 computerized tomography axial scans of patients without pelvic injury between 2 and 18 year-old were studied. The narrowest width of pubic symphysis and bilateral sacroiliac joints were measured. The average pubic symphyseal width at 2 years old boys was 6.35 ± 1.06 mm (4.88-9.13 mm). The average of right and left sacroiliac joints' widths at 2 years old boys was 4.56 ± 0.65 mm (3.59-6.07 mm) and 4.58 ± 0.66 mm (3.44-5.74 mm), respectively. The average pubic symphyseal width of 2 years old girls was 5.85 ± 1.14 mm (4.06-8.20 mm). The average of right and left sacroiliac joints' widths at 2 years old girls was found 4.36 ± 0.56 mm (3.50-5.37 mm) and 4.42 ± 0.59 mm (3.58-5.73 mm), respectively. The average pubic symphyseal width at 18 years old boys was found 3.68 ± 1.30 mm (1.90-5.79 mm). The average of right and left sacroiliac joints' widths at 18 years old boys was found 1.97 ± 0.21 mm (1.73-2.41 mm) and 2.04 ± 0.30 mm (1.70-2.65 mm), respectively. The average pubic symphyseal width at 18 years old girls was 3.92 ± 0.52 mm (2.97-4.76 mm). The average of right and left sacroiliac joints' widths at 18 years old girls was found 2.34 ± 0.40 mm (1.58-3.34 mm) and 2.33 ± 0.37 mm (1.58-3.10 mm), respectively. Our results suggest that one should be suspicious about pelvic injury if the width of pubic symphysis is over 10 mm and width of sacroiliac joint is over 8 mm especially in patients younger than 10 years-old. Level III Diagnostic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  18. Red herring: Acute back pain after combined spinal epidural for labor analgesia

    Directory of Open Access Journals (Sweden)

    Yoong Chuan Tay

    2018-04-01

    Full Text Available Symphysis pubis diastases complicate 1:300 to 1:30,000 pregnancies. Peripartum pain in chronological sequence with labor epidural analgesia often attracts instinctive causation and distress. Predisposing risk factors include macrosomia, short second stage of labor, forceps use, multiparity, small pelvis, intense uterine contractions, previous pelvic ring pathology and trauma. A gestational diabetic primigravid parturient presents with acute post-partum back pain after an uneventful analgesic labor epidural. Her pain distributed over the right paravertebral L5-S1 region without radiculopathy, worsened with positional change and accompanied by urinary incontinence, precluding child care. Spine imaging incidentally revealed a 38 mm symphysis pubis diastasis. A pelvic binder by orthopaedics aided physiotherapy and ambulation. Pubic diastases are usually conservatively managed, unless separation exceeds 5 cm when early surgery may improve functional outcomes. Although symptoms may recur in subsequent pregnancies, it does not preclude vaginal delivery. Early recognition and prompt management aim to reduce parturient morbidity and promote resumption of activity. Keywords: Symphysis pubis diasthesis, Pubic symphysis diasthesis, Post-epidural pain, Labor epidural pain, Post-partum pain

  19. Defining forces that are associated with shoulder dystocia: the use of a mathematic dynamic computer model.

    Science.gov (United States)

    Gonik, Bernard; Zhang, Ning; Grimm, Michele J

    2003-04-01

    A computer model was modified to study the impact of maternal endogenous and clinician-applied exogenous delivery loads on the contact force between the anterior fetal shoulder and the maternal symphysis pubis. Varying endogenous and exogenous loads were applied, and the contact force was determined. Experiments also examined the effect of pelvic orientation and the direction of load application on contact force behind the symphysis pubis. Exogenous loading forces (50-100 N) resulted in anterior shoulder contact forces of 107 to 127 N, with delivery accomplished at 100 N of applied load. Higher contact forces (147-272 N) were noted for endogenously applied loads (100-400 N), with delivery occurring at 400 N of maternal force. Pelvic rotation from lithotomy to McRoberts' positioning resulted in reduced contact forces. Downward lateral flexion of the fetal head led to little difference in contact force but required 30% more exogenous load to achieve delivery. Compared with clinician-applied exogenous force, larger maternally derived endogenous forces are needed to clear the impacted anterior fetal shoulder. This is associated with >2 times more contact force by the obstructing symphysis pubis. McRoberts' positioning reduces shoulder-symphysis pubis contact force. Lateral flexion of the fetal head results in the larger forces that are needed for delivery but has little effect on contact force. Model refinements are needed to examine delivery forces and brachial plexus stretching more specifically.

  20. Prevalence of Pthirus pubis (Anoplura: Pediculidae) among sex workers in urban Jos, Nigeria.

    Science.gov (United States)

    Imandeh, N G

    1993-11-01

    Between May and October 1992, 374 sex workers comprising of 372 prostitutes and 2 homosexuals were examined for Pthirus pubis infestation. While none of the homosexuals was found to be infested, 52.69% of the prostitutes were infested with the highest and lowest infestation in the 40-49 year old group and 20-29 year old group respectively. The educational level was found to determine the extent of disease awareness among the sex workers. Questions are raised about the role of Pthirus pubis is AIDS transmission among sex workers.

  1. The effect of dynamic femoroacetabular impingement on pubic symphysis motion: a cadaveric study.

    Science.gov (United States)

    Birmingham, Patrick M; Kelly, Bryan T; Jacobs, Robert; McGrady, Linda; Wang, Mei

    2012-05-01

    A link between femoroacetabular impingement and athletic pubalgia has been reported clinically. One proposed origin of athletic pubalgia is secondary to repetitive loading of the pubic symphysis, leading to instability and parasymphyseal tendon and ligament injury. Hypothesis/ The purpose of this study was to investigate the effect of simulated femoral-based femoroacetabular impingement on rotational motion at the pubic symphysis. The authors hypothesize that the presence of a cam lesion leads to increased relative symphyseal motion. Controlled laboratory study. Twelve hips from 6 fresh-frozen human cadaveric pelvises were used to simulate cam-type femoroacetabular impingement. The hips were held in a custom jig and maximally internally rotated at 90° of flexion and neutral adduction. Three-dimensional motion of the pubic symphysis was measured by a motion-tracking system for 2 states: native and simulated cam. Load-displacement plots were generated between the internal rotational torque applied to the hip and the responding motion in 3 anatomic planes of the pubic symphysis. As the hip was internally rotated, the motion at the pubic symphysis increased proportionally with the degrees of the rotation as well as the applied torque measured at the distal femur for both states. The primary rotation of the symphysis was in the transverse plane and on average accounted for more than 60% of the total rotation. This primary motion caused the anterior aspect of the symphyseal joint to open or widen, whereas the posterior aspect narrowed. At the torque level of 18.0 N·m, the mean transverse rotation in degrees was 0.89° ± 0.35° for the native state and 1.20° ± 0.41° for cam state. The difference between cam and the native groups was statistically significant (P pubalgia.

  2. ORIGINAL ARTICLE ORIG ORIG CT for upper abdominal pathology ...

    African Journals Online (AJOL)

    ORIG. 14. SA JOURNAL OF RADIOLOGY • March 2007. ORIG. Abstract. Background. Current practice at our institution for routine abdominal. CT includes coverage from the diaphragm to the symphysis pubis and therefore includes pelvic organs. Limited upper abdominal imaging exists in other modalities, and tailoring the ...

  3. Quantitation of mandibular symphysis volume as a source of bone grafting.

    Science.gov (United States)

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2010-06-01

    Autogenous intramembranous bone graft present several advantages such as minimal resorption and high concentration of bone morphogenetic proteins. A method for measuring the amount of bone that can be harvested from the symphysis area has not been reported in real patients. The aim of the present study was to intrasurgically quantitate the volume of the symphysis bone graft that can be safely harvested in live patients and compare it with AutoCAD (version 16.0, Autodesk, Inc., San Rafael, CA, USA) tomographic calculations. AutoCAD software program quantitated symphysis bone graft in 40 patients using computerized tomographies. Direct intrasurgical measurements were recorded thereafter and compared with AutoCAD data. The bone volume was measured at the recipient sites of a subgroup of 10 patients, 6 months post sinus augmentation. The volume of bone graft measured by AutoCAD averaged 1.4 mL (SD 0.6 mL, range: 0.5-2.7 mL). The volume of bone graft measured intrasurgically averaged 2.3 mL (SD 0.4 mL, range 1.7-2.8 mL). The statistical difference between the two measurement methods was significant. The bone volume measured at the recipient sites 6 months post sinus augmentation averaged 1.9 mL (SD 0.3 mL, range 1.3-2.6 mL) with a mean loss of 0.4 mL. AutoCAD did not overestimate the volume of bone that can be safely harvested from the mandibular symphysis. The use of the design software program may improve surgical treatment planning prior to sinus augmentation.

  4. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    Science.gov (United States)

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  5. Selective Nonoperative Management of Penetrating Torso Injury From Combat Fragmentation Wounds

    Science.gov (United States)

    2008-02-01

    outlines the paradigm of care: “Penetrating inju- ries below the nipples , above the symphysis pubis, and between the posterior axillary lines must be...abdo- men and were hemodynamically stable and without abdom- inal pain or tenderness. CT scan of some of these casualties revealed fragments in the lumen

  6. Review Article

    African Journals Online (AJOL)

    2007-12-02

    Dec 2, 2007 ... Introduction. What prompted this review article is because of the wrong notion that the only standard abdominal incision is the midline incision. Cases have been seen in which an abdominal incision extends from the xyphoid process to the symphysis pubis just to remove a perforated appendix! The reason ...

  7. 64-year-old male with septic arthritis of the pubic symphysis

    Directory of Open Access Journals (Sweden)

    Mark Lee

    2011-09-01

    Full Text Available Septic arthritis of the pubic symphysis is a rare disease. Typical clinical features include fever, pubic or groin pain, pain with hip motion, and painful or waddling gait. Identified predisposing factors to develop an infection in pubic joint include female incontinence surgery or postpartum period; sports, especially soccer; pelvic malignancy; and intravenous drug abuse. The most often identified microorganisms were Staphylococcus aureus and Pseudomonas aeruginosa. Osteomyelitis complicates the majority of cases, and about half of the patients require surgical debridement along with a prolonged antibiotic treatment. We report a case of Streptococcus anginosus septic arthritis of the pubic symphysis. The patient did not have any of the above risk factors.

  8. 64-year-old male with septic arthritis of the pubic symphysis

    Directory of Open Access Journals (Sweden)

    Ewa Konik

    2011-10-01

    Full Text Available Septic arthritis of the pubic symphysis is a rare disease. Typical clinical features include fever, pubic or groin pain, pain with hip motion, and painful or waddling gait. Identified predisposing factors to develop an infection in pubic joint include female incontinence surgery or postpartum period; sports, especially soccer; pelvic malignancy; and intravenous drug abuse. The most often identified microorganisms were Staphylococcus aureus and Pseudomonas aeruginosa. Osteomyelitis complicates the majority of cases, and about half of the patients require surgical debridement along with a prolonged antibiotic treatment. We report a case of Streptococcus anginosus septic arthritis of the pubic symphysis. The patient did not have any of the above risk factors.

  9. Relationship between the position of upper and lower incisors and the internal structure of symphysis

    International Nuclear Information System (INIS)

    Suzuki, Kayou; Nishide, Masashi; Ishii, Yasumasa; Enomoto, Yutaka; Kawamura, Akira; Kasai, Kazutaka

    2002-01-01

    The aim of this study was to investigate the relationship between the position of the upper and lower incisors and cortical bone thickness and CT value of mandibular symphysis obtained by CT images and cephalograms. The specimens were 24 dry skulls of mordern Japanese males (mean age 29 years) without marked crowding and missing tooth, which had been preserved in the Tokyou University Museum. The data were transferred to a workstation, and CT value and thickness of cortical bone were measured. The dentofacial morphology was investigated with a lateral cephalogram. The results were as follows; The thickness of cortal bone was more thicker in order of basal, lingual and labial cortical bone. The CT value showed the same tendency as cortical bone thickness. Significant correlation coefficients were found between cortical bone thickness and CT value in 30, 60, 90, 120 degree areas. The inclination of upper incisors was negatively related to the CT value in basal and lingual region of symphysis. The inclination of lower incisors was positively related to the CT value in basal and lingual region of symphysis. The interincisor angle was positively related to the CT value in basal region of symphysis. In conclusion, the results of this study suggested that the labio-lingual inclination of the upper and lower incisors was associated with the CT value of basal region of sysphysis. It is suggested that the internal structures of symphysis which relate to the occlusion types of incisors are affected by function of masticatory muscles. (author)

  10. Agreement between fiber optic and optoelectronic systems for quantifying sagittal plane spinal curvature in sitting.

    Science.gov (United States)

    Cloud, Beth A; Zhao, Kristin D; Breighner, Ryan; Giambini, Hugo; An, Kai-Nan

    2014-07-01

    Spinal posture affects how individuals function from a manual wheelchair. There is a need to directly quantify spinal posture in this population to ultimately improve function. A fiber optic system, comprised of an attached series of sensors, is promising for measuring large regions of the spine in individuals sitting in a wheelchair. The purpose of this study was to determine the agreement between fiber optic and optoelectronic systems for measuring spinal curvature, and describe the range of sagittal plane spinal curvatures in natural sitting. Able-bodied adults (n = 26, 13 male) participated. Each participant assumed three sitting postures: natural, slouched (accentuated kyphosis), and extension (accentuated lordosis) sitting. Fiber optic (ShapeTape) and optoelectronic (Optotrak) systems were applied to the skin over spinous processes from S1 to C7 and used to measure sagittal plane spinal curvature. Regions of kyphosis and lordosis were identified. A Cobb angle-like method was used to quantify lordosis and kyphosis. Generalized linear model and Bland-Altman analyses were used to assess agreement. A strong correlation exists between curvature values obtained with Optotrak and ShapeTape (R(2) = 0.98). The mean difference between Optotrak and ShapeTape for kyphosis in natural, extension, and slouched postures was 4.30° (95% LOA: -3.43 to 12.04°), 3.64° (95% LOA: -1.07 to 8.36°), and 4.02° (95% LOA: -2.80 to 10.84°), respectively. The mean difference for lordosis, when present, in natural and extension postures was 2.86° (95% LOA: -1.18 to 6.90°) and 2.55° (95% LOA: -3.38 to 8.48°), respectively. In natural sitting, the mean ± SD of kyphosis values was 35.07 ± 6.75°. Lordosis was detected in 8/26 participants: 11.72 ± 7.32°. The fiber optic and optoelectronic systems demonstrate acceptable agreement for measuring sagittal plane thoracolumbar spinal curvature. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. US in pubalgia.

    Science.gov (United States)

    Balconi, Giuseppe

    2011-09-01

    There is considerable confusion over the word "pubalgia" with regard to the definition and the etiological causes of this condition. The term pubalgia should be used to indicate disabling pain affecting the pubic region in people who practise sports. Pubalgia affects 10% of those who practise sports and it is particularly prevalent in football players. According to the literature, about 40% of cases of pubalgia are caused by overuse of the symphysis pubis with progressive lesions affecting the rectus abdominal muscles, adductors (rectal-adductor syndrome) and the symphysis itself (osteitis pubis and joint injury). An initial study of the tendons is carried out by ultrasound (US) whereas magnetic resonance imaging (MRI) should be performed to study the bones and joints.Another 40% of cases of pubalgia are caused by "sports hernia" defined as anteroinferior abdominal wall insufficiency. These alterations can only be identified at dynamic US examination.About 20% of cases of pubalgia are caused by diseases of the neighboring structures or joints such as diseases of the hip, iliopsoas, hamstring, sacred iliac or nerves, or by urogenital diseases.

  12. Age- and gender-related characteristics of the pubic symphysis and triradiate cartilage in pediatric computed tomography

    International Nuclear Information System (INIS)

    Bayer, Joerg; Suedkamp, Norbert P.; Reising, Kilian; Neubauer, Jakob; Saueressig, Ulrich

    2016-01-01

    There is little information on the pubic symphysis' normal CT appearance in children. We sought to generate age-, gender- and maturity-related symphyseal width appearances in CT scans. Pelvic CT scans performed for any reason during a 6-year period in patients younger than 18 years were retrospectively analyzed. The symphysis width was measured in the axial plane and the triradiate cartilage was classified as open or closed. Four hundred twenty-seven CT scans were evaluated and 350 remained for analysis. Age- and gender-related measurements of the symphysis width are illustrated on various centile graphs. When grouping children by age in years 0-6, 7-11, 12-15 and 16-17, mean (standard deviation) symphysis width was 5.4 mm (0.9), 5.3 mm (1.1), 4.1 mm (1.1) and 3.5 mm (1.0), respectively, in girls and 5.9 mm (1.3), 5.4 mm (1.2), 5.2 mm (1.1) and 4.0 mm (1.0), respectively, in boys. Boys and girls were significantly different in the age groups 12-15 years (P<0.001) and 16-17 years (P=0.04). In the mature pelvis, the symphyseal gap is significantly (P<0.001) shorter in both genders, and in girls compared to boys (P=0.04). The pubic symphysis width in children differs according to age, gender and maturity. The reference values published herein may help detect symphyseal injury. (orig.)

  13. Age- and gender-related characteristics of the pubic symphysis and triradiate cartilage in pediatric computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Joerg; Suedkamp, Norbert P.; Reising, Kilian [Medical Centre -University of Freiburg, Department of Orthopedics and Trauma Surgery, Freiburg (Germany); Neubauer, Jakob [Medical Centre - University of Freiburg, Department of Radiology, Freiburg (Germany); Saueressig, Ulrich [Kreiskrankenhaus Emmendingen, Department of Radiology, Emmendingen (Germany)

    2016-11-15

    There is little information on the pubic symphysis' normal CT appearance in children. We sought to generate age-, gender- and maturity-related symphyseal width appearances in CT scans. Pelvic CT scans performed for any reason during a 6-year period in patients younger than 18 years were retrospectively analyzed. The symphysis width was measured in the axial plane and the triradiate cartilage was classified as open or closed. Four hundred twenty-seven CT scans were evaluated and 350 remained for analysis. Age- and gender-related measurements of the symphysis width are illustrated on various centile graphs. When grouping children by age in years 0-6, 7-11, 12-15 and 16-17, mean (standard deviation) symphysis width was 5.4 mm (0.9), 5.3 mm (1.1), 4.1 mm (1.1) and 3.5 mm (1.0), respectively, in girls and 5.9 mm (1.3), 5.4 mm (1.2), 5.2 mm (1.1) and 4.0 mm (1.0), respectively, in boys. Boys and girls were significantly different in the age groups 12-15 years (P<0.001) and 16-17 years (P=0.04). In the mature pelvis, the symphyseal gap is significantly (P<0.001) shorter in both genders, and in girls compared to boys (P=0.04). The pubic symphysis width in children differs according to age, gender and maturity. The reference values published herein may help detect symphyseal injury. (orig.)

  14. Clinical implications of a close vicinity of nervus dorsalis penis/clitoridis and os pubis

    Czech Academy of Sciences Publication Activity Database

    Šedý, Jiří; Naňka, O.; Špačková, J.; Jarolím, L.

    2008-01-01

    Roč. 5, č. 7 (2008), s. 1572-1581 ISSN 1743-6095 R&D Projects: GA MŠk 1M0538 Institutional research plan: CEZ:AV0Z50390512; CEZ:AV0Z50110509 Keywords : Dorsal Nerve of Penis * Dorsal Nerve of Clitoris * Pubis Subject RIV: FH - Neurology Impact factor: 5.393, year: 2008

  15. Lower incisor dentoalveolar compensation and symphysis dimensions among Class I and III malocclusion patients with different facial vertical skeletal patterns.

    Science.gov (United States)

    Molina-Berlanga, Núria; Llopis-Perez, Jaume; Flores-Mir, Carlos; Puigdollers, Andreu

    2013-11-01

    To compare lower incisor dentoalveolar compensation and mandible symphysis morphology among Class I and Class III malocclusion patients with different facial vertical skeletal patterns. Lower incisor extrusion and inclination, as well as buccal (LA) and lingual (LP) cortex depth, and mandibular symphysis height (LH) were measured in 107 lateral cephalometric x-rays of adult patients without prior orthodontic treatment. In addition, malocclusion type (Class I or III) and facial vertical skeletal pattern were considered. Through a principal component analysis (PCA) related variables were reduced. Simple regression equation and multivariate analyses of variance were also used. Incisor mandibular plane angle (P Class I P  =  .03 and Class III P  =  .01) and a positive correlation with LH (Class I P  =  .01 and Class III P  =  .02) in both groups. Within the Class III group, there was a negative correlation between the mandibular plane and LP (P  =  .02). PCA showed that the tendency toward a long face causes the symphysis to elongate and narrow. In Class III, alveolar narrowing is also found in normal faces. Vertical facial pattern is a significant factor in mandibular symphysis alveolar morphology and lower incisor positioning, both for Class I and Class III patients. Short-faced Class III patients have a widened alveolar bone. However, for long-faced and normal-faced Class III, natural compensation elongates the symphysis and influences lower incisor position.

  16. The role of allofibroblasts transplantation in cartilaginous tissue regeneration process

    OpenAIRE

    Khadjibaev Аbdukhakim Muminovich; Tilyakov Akbar Buriyevich; Magrupov Bokhodir Asadullaevich; Urazmetova Maisa Dmitriyevna; Ubaydullaev Bobur Sabirovich

    2017-01-01

    Aim of investigation. Ground of embryonal allofibroblasts in the process of cartilaginous tissue regeneration. Material and methods. Investigation is based on the study the results of stimulation cartilaginous tissue regeneration process in the conditions of embryonal allofibroblasts application in 24 experimental sexually mature rabbits in which the model of symphysis pubis rupture with its following recovery have been used. Pieces of cartilaginous tissue have been fixed in 10% neutral forma...

  17. Grading Scale of Radiographic Findings in the Pubic Bone and Symphysis in Athletes

    International Nuclear Information System (INIS)

    Besjakov, J.; Scheele, C. von; Ekberg, O.; Gentz, C. F.; Westlin, N.E.

    2003-01-01

    Purpose: Radiographic abnormalities in the pubic bone and symphysis are often seen in athletes with groin pain. The aim was to create a grading scale of such radiologic changes. Material and Methods: Plain radiography of the pelvic ring including the pubic bone and the symphysis was performed in 20 male athletes, age 19-35, with long-standing uni- or bilateral groin pain. We used two control groups: Control group 1: 20 healthy age-matched men who had undergone radiologic examination of the pelvis due to trauma. Control group 2: 120 adults (66 men and 54 women) in 9 age groups between 15 and 90 years of age. These examinations were also evaluated for interobserver variance. Results and Conclusion: The grading scale was based on the type and the amount of the different changes, which were classified as follows: No bone changes (grade 0), slight bone changes (grade 1), intermediate changes (grade 2), and advanced changes (grade 3). The grading scale is easy to interpret and an otherwise troublesome communication between the radiologist and the physician was avoided. There was a high interobserver agreement with a high kappa value (0.8707). Male athletes with long-standing groin pain had abnormal bone changes in the symphysis significantly more frequently and more severely (p>0.001) than their age-matched references. In asymptomatic individuals such abnormalities increased in frequency with age both in men and women

  18. How much vertical displacement of the symphysis indicates instability after pelvic injury?

    Science.gov (United States)

    Golden, Robert D; Kim, Hyunchul; Watson, Jeffrey D; Oliphant, Bryant W; Doro, Christopher; Hsieh, Adam H; Osgood, Greg M; O'Toole, Robert V

    2013-02-01

    Measures of pubic symphyseal widening are used by at least two classification systems as determinants of injury grade. Recent work has challenged the commonly used parameter of 2.5 cm of pubic symphysis as an accurate marker of pelvic injury grade and has suggested a role of rotation in the flexion-extension plane as a determinant of pelvic stability. We investigated pelvic stability in the flexion-extension plane to determine a threshold of rotational displacement of the hemipelvis above which the potential for instability exists. Cadaveric specimens were mounted onto a servohydraulic biaxial testing machine and subjected to a vertically directed flexion moment. Position of hemipelvis was recorded using a three-dimensional motion capture system and video recording. Displacement of the pubic symphysis and changes in length and position of the sacrospinous and sacrotuberous ligaments were recorded. Amount of force applied was measured and recorded. A yield point was determined as the first point at which the force plot exhibited a decrease in force and was correlated to the corresponding displacement. The mean vertical displacement of the pubic symphysis at the yield point was 16 mm (95% confidence interval, 11-22 mm). Mean sacrospinous ligament strain at yield point was 4% (range, 1.0-9.5%). Pelves with vertical rotational symphyseal displacement of less than 11 mm can reasonably be expected to have rotational stability in the flexion-extension plane. Those with displacement of greater than 22 mm can be expected to have lost some integrity regarding resistance to pelvic flexion. These values may allow clinicians to infer pelvic stability from amount of vertical symphyseal displacement.

  19. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    International Nuclear Information System (INIS)

    Tuite, M.J.; Asinger, D.; Orwin, J.F.

    2001-01-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  20. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Asinger, D; Orwin, J F [Dept. of Radiology, Univ. of Wisconsin Hospital and Clinics, Madison, WI (United States)

    2001-05-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  1. Abdominoplastia y pexia de pubis: estandarización de medidas

    Directory of Open Access Journals (Sweden)

    O. Ballestas-Campo

    2014-06-01

    Full Text Available La abdominoplastia es el procedimiento de elección para corregir la flacidez abdominal, la lipodistrofia supra e infraumbilical y la diástasis de los rectos abdominales. Los nuevos métodos añaden liposucción para definir el contorno corporal. Presentamos una estandarización de medidas para lograr una cicatriz abdominal baja y pexia pubiana en casos de lipodistrofias tipo III y IV de Matarasso. Realizamos un estudio observacional, descriptivo y retrospectivo, evaluando las historias clínicas y las fotografías sobre 420 mujeres, con edades entre 18 y 63 años, intervenidas entre 2004 y 2011. Basamos la técnica quirúrgica en los siguientes principios: referencias anatómicas; medidas estandarizadas con la paciente de pie sobre zapatos de tacón alto para el trazado de una incisión suprapúbica baja, siguiendo diseño de los autores; pexia de pubis y región inguinal; cicatriz suprapúbica baja cubierta por un biquini estándar. El 70,95 % de los casos (298 pacientes correspondieron a abdomen grado IV de lipodistrofia, el 28,57 % (120 pacientes al grado III y el 0,47 % (2 pacientes al grado II según Matarasso. Las complicaciones más frecuentes fueron: seroma, (4,04 % , alteraciones cicatríciales (7,37 % , necrosis parcial y epidermolisis (2,38 % y estenosis umbilical (1,19 % . Como conclusión creemos que la estandarización de medidas para el diseño de la cicatriz en la abdominoplastia permite obtener resultados estéticos predecibles y funcionales buenos: cicatriz baja cubierta por un biquini o ropa interior estándar, cicatriz umbilical ovalada, pexia de pubis y excelente definición del contorno abdominal y corporal, con baja tasa de complicaciones.

  2. CLINICAL TESTS FOR THE ASSESSMENT OF THE PELVIC GIRDLE PAIN IN PREGNANCY AND POSTPARTUM

    Directory of Open Access Journals (Sweden)

    Darija Šćepanović

    2018-02-01

    Full Text Available Background: Pregnancy-related pelvic girdle pain (PGP refers to the pain in the lumbosacral region, the sacroiliac joints and the symphysis pubis joint. The results of the high methodological quality studies indicate that the point prevalence of pregnant women suffering from PGP is about 20 %. Pregnancy-related PGP requires a comprehensive physiotherapy assessment in order to make or confirm a diagnosis, plan the treatment and evaluate the patient’s condi- tion. Physiotherapy assessment includes clinical diagnostic tests which should satisfy the criteria of safety, feasibility, reliability, sensitivity, specificity and validity. The aim of the present paper was to systematically review the literature on clinical diagnostic tests of PGP in order to determine which clinical tests meet the necessary criteria and are appropriate for clinical examination of PGP in pregnancy and postpartum. Methods: PubMed, Cinahl, Embase, Index Medicus databases and the Cochrane controlled trials reg- ister from 1980 to 2008 were searched using the key words, pregnancy/pelvic girdle pain, pregnancy/clinical tests/sacroiliac joint/symphysis pubis. Only the articles/texts in English and Slovene were reviewed unless translated abstract was available. Additional manual searches of the reference lists in books and review articles were undertaken. Along with the randomized clinical studies the literature search encompassed also the basic studies. Results: Nine studies evaluating the tests for clinical examination of the pregnancy-related PGP met the criteria for inclusion in this review. The studies evaluated and analysed six provocation tests for the sacroiliac joint, namely, the Posterior pelvic pain provocation test (P4, Patrick’s Faber test, palpation of the long dorsal ligament, compression test, separation test, Menell’s test as well as two provocation tests for the symphysis pubis joint (pain palpation and a modified Trendelenburg test and one functional

  3. [Forensic Analysis of the Characteristics of Pelvic Fracture in 65 Road Traffic Accident Death Cases].

    Science.gov (United States)

    Zhang, W

    2016-12-01

    To analyze the characteristics and mechanisms of pelvic fractures in the cases of road traffic accident deaths. Total 65 cases of road traffic accident deaths with pelvic fracture were collected, and the sites, characteristics and injury mechanisms of pelvic fracture were statistically analyzed. Among the 65 cases of pelvic fracture, 38 cases of dislocation of sacroiliac joint were found, and most combined with pubis symphysis separation or fracture of pubis. In the fractures of pubis, ischium and acetabulum, linear fractures were most common, while comminuted fractures were most common in sacrum and coccyx fractures. There were 54 cases combined with pelvic soft tissue injury, and 8 cases with pelvic organ injury and 44 cases with abdominal organ injury. In the types of pelvic ring injury, 32 cases were separation, 49.32%, followed by compression, 26.15% and only one case was verticality, 1.54%. Detailed and comprehensive examination of the body and determination of the pelvic fracture type contribute to analyze the mechanisms of injury. Copyright© by the Editorial Department of Journal of Forensic Medicine

  4. US in pubalgia

    OpenAIRE

    Balconi, Giuseppe

    2011-01-01

    There is considerable confusion over the word “pubalgia” with regard to the definition and the etiological causes of this condition. The term pubalgia should be used to indicate disabling pain affecting the pubic region in people who practise sports. Pubalgia affects 10% of those who practise sports and it is particularly prevalent in football players. According to the literature, about 40% of cases of pubalgia are caused by overuse of the symphysis pubis with progressive lesions affecting th...

  5. Management of fractures of the mandibular body and symphysis.

    Science.gov (United States)

    Goodday, Reginald H B

    2013-11-01

    Mandibular fracture, specifically in the symphysis and body regions combined, is the most common facial fracture requiring hospitalization in North America. The primary treatment objective is to restore form and function by achieving anatomic reduction and placing fixation that eliminates mobility of the bone fragments. Several treatment options and surgical techniques are available for performing closed or open reduction. Special considerations are necessary when treating pediatric patients and fractures of the edentulous mandible. Complications relating to the tooth and denture-bearing regions of the mandible include infection, nonunion, and neurosensory changes. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Miniplate for osteosynthesis in a 9-year-old with symphysis fracture: clinical report.

    Science.gov (United States)

    Srinivasan, Ila; Kumar, Naveen; Jaganathan, Udhya; Bhandari, Arihant

    2013-09-01

    Osteosynthesis using minimum material in pediatric mandibular fractures is the key, due to the limited space available in the mandible, especially in the mental foramen and apical region. There is an important role of open reduction and rigid internal fixation in re-establishing facial height, width and projection. During the early years of growth and development, there is a high osteogenic potential of the bones. The thick periosteum allows for rapid consolidation and remodeling at the site of fracture. Primary teeth have short, bulbous crowns which compromise stable maxillomandibular fixation during fracture reduction and stabilization using traditional methods. Further, stability of the fractured segments may be hampered because of the displaced or mobile permanent anterior teeth in the mixed dentition along the line of fracture. This clinical report outlines the use of miniplate with monocortical screws in a 9-year-old boy with symphysis fracture. How to cite this article: Srinivasan I, Kumar N, Jaganathan U, Bhandari A. Miniplate for Osteosynthesis in a 9-Year-Old with Symphysis Fracture: Clinical Report. Int J Clin Pediatr Dent 2013;6(3):213-216.

  7. The use of the T1 sagittal angle in predicting overall sagittal balance of the spine.

    Science.gov (United States)

    Knott, Patrick T; Mardjetko, Steven M; Techy, Fernando

    2010-11-01

    A balanced sagittal alignment of the spine has been shown to strongly correlate with less pain, less disability, and greater health status scores. To restore proper sagittal balance, one must assess the position of the occiput relative to the sacrum. The assessment of spinal balance preoperatively can be challenging, whereas predicting postoperative balance is even more difficult. This study was designed to evaluate and quantify multiple factors that influence sagittal balance. Retrospective analysis of existing spinal radiographs. A retrospective review of 52 adult spine patient records was performed. All patients had full-column digital radiographs that showed all the important skeletal landmarks necessary for accurate measurement. The average age of the patient was 53 years. Both genders were equally represented. The radiographs were measured using standard techniques to obtain the following parameters: scoliosis in the coronal plane; lordosis or kyphosis of the cervical, thoracic, and lumbar spine; the T1 sagittal angle (angle between a horizontal line and the superior end plate of T1); the angle of the dens in the sagittal plane; the angle of the dens in relation to the occiput; the sacral slope; the pelvic incidence; the femoral-sacral angle; and finally, the sagittal vertical axis (SVA) measured from both the dens of C2 and from C7. It was found that the SVA when measured from the dens was on average 16 mm farther forward than the SVA measured from C7 (p<.0001). The dens plumb line (SVA(dens)) was then used in the study. An analysis was done to examine the relationship between SVA(dens) and each of the other measurements. The T1 sagittal angle was found to have a moderate positive correlation (r=0.65) with SVA(dens), p<.0001, indicating that the amount of sagittal T1 tilt can be used as a good predictor of overall sagittal balance. When examining the other variables, it was found that cervical lordosis had a weak correlation (r=0.37) with SVA(dens) that was

  8. Tape edge study in a linear tape drive with single-flanged guides

    International Nuclear Information System (INIS)

    Goldade, A.V.; Bhushan, Bharat

    2004-01-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge

  9. MRI in patients with chronic pubalgia: Is precise useful information provided to the surgeon? A case-control study.

    Science.gov (United States)

    Larbi, A; Pesquer, L; Reboul, G; Omoumi, P; Perozziello, A; Abadie, P; Loriaut, P; Copin, P; Ducouret, E; Dallaudière, B

    2016-10-01

    Recent studies described that MRI is a good examination to assess damage in chronic athletic pubalgia (AP). However, to our knowledge, no studies focus on systematic correlation of precise tendon or parietal lesion in MRI with surgery and histological assessment. Therefore, we performed a case-control study to determine if MRI can precisely assess Adductor longus (AL) tendinopathy and parietal lesion, compared with surgery and histology. MRI can determine if AP comes from pubis symphysis, musculotendinous or inguinal orifice structures. Eighteen consecutive patients were enrolled from November 2011 to April 2013 for chronic AP. To constitute a control group, we also enrolled 18 asymptomatic men. All MRI were reviewed in consensus by 2 skeletal radiologists for pubic symphysis, musculotendinous, abdominal wall assessment and compared to surgery and histology findings. Regarding pubis symphysis, we found 4 symmetric bone marrow oedema (14%), 2 secondary cleft (7%) and 2 superior ligaments lesions (7%). For AL tendon, we mainly found 13 asymmetric bone marrow oedema (46%), 15 hyperaemia (54%). Regarding abdominal wall, the deep inguinal orifice size in the group of symptomatic athletes and the control group was respectively 27.3±6.4mm and 23.8±6.3mm. The correlation between MRI and surgery/histology was low: 20% for the AL tendon and 9% for the abdominal wall. If we chose the criteria "affected versus unaffected", this correlation became higher: 100% for AL tendon and 73% for the abdominal wall. MRI chronic athletic pubalgia concerns preferentially AL tendinopathy and deep inguinal canal dehiscence with high correlation to surgery/histology when only considering the item "affected versus unaffected" despite low correlation when we try to precisely grade these lesions. III: case-control study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Tape transport mechanism

    International Nuclear Information System (INIS)

    Groh, E.F.; McDowell, W.; Modjeski, N.S.; Keefe, D.J.; Groer, P.

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer

  11. Sagittal crest formation in great apes and gibbons.

    Science.gov (United States)

    Balolia, Katharine L; Soligo, Christophe; Wood, Bernard

    2017-06-01

    The frequency of sagittal crest expression and patterns of sagittal crest growth and development have been documented in hominoids, including some extinct hominin taxa, and the more frequent expression of the sagittal crest in males has been traditionally linked with the need for larger-bodied individuals to have enough attachment area for the temporalis muscle. In the present study, we investigate sagittal cresting in a dentally mature sample of four hominoid taxa (Pan troglodytes schweinfurthii, Gorilla gorilla gorilla, Pongo pygmaeus pygmaeus and Hylobates lar). We investigate whether sagittal crest size increases with age beyond dental maturity in males and females of G. g. gorilla and Po. pyg. pygmaeus, and whether these taxa show sex differences in the timing of sagittal crest development. We evaluate the hypothesis that the larger sagittal crest of males may not be solely due to the requirement for a larger surface area than the un-crested cranial vault can provide for the attachment of the temporalis muscle, and present data on sex differences in temporalis muscle attachment area and sagittal crest size relative to cranial size. Gorilla g. gorilla and Po. pyg. pygmaeus males show significant relationships between tooth wear rank and sagittal crest size, and they show sagittal crest size differences between age groups that are not found in females. The sagittal crest emerges in early adulthood in the majority of G. g. gorilla males, whereas the percentage of G. g. gorilla females possessing a sagittal crest increases more gradually. Pongo pyg. pygmaeus males experience a three-fold increase in the number of specimens exhibiting a sagittal crest in mid-adulthood, consistent with a secondary growth spurt. Gorilla g. gorilla and Po. pyg. pygmaeus show significant sex differences in the size of the temporalis muscle attachment area, relative to cranial size, with males of both taxa showing positive allometry not shown in females. Gorilla g

  12. Surgical management of complete penile duplication accompanied by multiple anomalies.

    Science.gov (United States)

    Karaca, Irfan; Turk, Erdal; Ucan, A Basak; Yayla, Derya; Itirli, Gulcin; Ercal, Derya

    2014-09-01

    Diphallus (penile duplication) is very rare and seen once every 5.5 million births. It can be isolated, but is usually accompanied by other congenital anomalies. Previous studies have reported many concurrent anomalies, such as bladder extrophy, cloacal extrophy, duplicated bladder, scrotal abnormalities, hypospadias, separated symphysis pubis, intestinal anomalies and imperforate anus; no penile duplication case accompanied by omphalocele has been reported. We present the surgical management of a patient with multiple anomalies, including complete penile duplication, hypo-gastric omphalocele and extrophic rectal duplication.

  13. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  14. Time-dependent regulation of morphological changes and cartilage differentiation markers in the mouse pubic symphysis during pregnancy and postpartum recovery.

    Science.gov (United States)

    Castelucci, Bianca Gazieri; Consonni, Sílvio Roberto; Rosa, Viviane Souza; Sensiate, Lucimara Aparecida; Delatti, Paula Cristina Rugno; Alvares, Lúcia Elvira; Joazeiro, Paulo Pinto

    2018-01-01

    Animal models commonly serve as a bridge between in vitro experiments and clinical applications; however, few physiological processes in adult animals are sufficient to serve as proof-of-concept models for cartilage regeneration. Intriguingly, some rodents, such as young adult mice, undergo physiological connective tissue modifications to birth canal elements such as the pubic symphysis during pregnancy; therefore, we investigated whether the differential expression of cartilage differentiation markers is associated with cartilaginous tissue morphological modifications during these changes. Our results showed that osteochondral progenitor cells expressing Runx2, Sox9, Col2a1 and Dcx at the non-pregnant pubic symphysis proliferated and differentiated throughout pregnancy, giving rise to a complex osteoligamentous junction that attached the interpubic ligament to the pubic bones until labour occurred. After delivery, the recovery of pubic symphysis cartilaginous tissues was improved by the time-dependent expression of these chondrocytic lineage markers at the osteoligamentous junction. This process potentially recapitulates embryologic chondrocytic differentiation to successfully recover hyaline cartilaginous pads at 10 days postpartum. Therefore, we propose that this physiological phenomenon represents a proof-of-concept model for investigating the mechanisms involved in cartilage restoration in adult animals.

  15. Circummandibular Wiring of Symphysis Fracture in a Five-Year-Old Child

    Directory of Open Access Journals (Sweden)

    Krishna Priya Vellore

    2013-01-01

    Full Text Available The treatment of pediatric maxillofacial fractures is unique due to the psychological, physiological, developmental, and anatomical characteristics of children. Method. This case report describes the management of symphysis fracture of mandible in a 5-year-old boy. The fracture was treated by acrylic splint with circummandibular wiring. Results. The splint was removed after 3 weeks. The patient had no complaints, and radiograph revealed a healed fracture. Conclusion. The clinical outcome in the present case indicates the management of mandibular fractures in pediatric patients using acrylic splint with circummandibular wiring.

  16. Anatomic landmarks of fluoroscopy guided puncture of the pulseless femoral artery

    International Nuclear Information System (INIS)

    Jeon, Min Hee; Han, Gi Seok; Kim, Sung Jin; Park, Kil Sun; Cha, Sang Hoon; Bae, Il Hun; Lee, Seung Young

    2006-01-01

    We wanted to improve puncturing the pulseless femoral artery by evaluating the anatomic landmarks that suggest the course of the femoral artery on fluoroscopy. We analyzed 37 hemipelvis spot images that were centered on the arterial sheath after puncture of the femoral artery. The inguinal angles were measured between the inguinal line connecting the anterior superior iliac spine and the symphysis pubis, and the line of the arterial sheath. Inguinal ligament ratios were measured as the distance from the symphysis pubis to the arterial sheath to the length of the inguinal ligament on the inguinal line. The femoral head ratios were measured as the distance from the medial margin of the femur head to the arterial sheath to the transverse length of the femur head. The mean inguinal angle was 66.5 and the mean inguinal ligament ratio was 0.42 (± 0.03). The mean femoral head ratio was 0.08 (± 0.18). In comparing the men and women, there was no significant difference in the inguinal angle and the femoral head ratio, but the inguinal distance ratio was larger in women (men: 0.41 ± 0.033, women: 0.44 ± 0.031, ρ < 0.05). The femoral artery generally courses just lateral to the medial margin of the femur head (femoral head ratio: 0.08) and the medial 40% of the inguinal ligament (inguinal ligament ratio: 0.42). So, consideration of these relations may be helpful for puncturing the pulseless femoral artery

  17. MR appearance of parasymphyseal insufficiency fractures of the os pubis

    Energy Technology Data Exchange (ETDEWEB)

    Hosono, Mariko; Fujimoto, Ryota; Konishi, Junji [Department of Nuclear Medicine, Faculty of Medicine, Kyoto University, 54 Shogoin-kawahara-cho, Sakyo-ku, Kyoto (Japan); Kobayashi, Hisataka [Nulcear Medicine Department, National Institutes of Health, Building 10, Room 1C-401, Bethesda, MD 20892 (United States); Tsutsui, Kazushige [Department of Radiology, Japanese Red Cross Society Wakayama Medical Center, Wakayama (Japan); Kotoura, Yoshihiko [Department of Orthopaedic Surgery, Nagahama City Hospital, Nagahama, Shiga (Japan); Tsuboyama, Tadao; Nakamura, Takashi [Department of Orthopaedic Surgery, Faculty of Medicine, Kyoto University, Kyoto (Japan); Hayashi, Hikaru [Department of Orthopaedic Surgery, Japanese Red Cross Society Wakayama Medical Center, Wakayama (Japan)

    1997-09-01

    Objective. To clarify the MRI features of parasymphyseal insufficiency fractures of the os pubis. Design and patients. MRI was performed in four postmenopausal women with parasymphyseal insufficiency fractures. The diagnosis was confirmed with plain films in every patient. T1-weighted and T2-weighted images were obtained in four patients using a 1.5-T unit. Postcontrast T1-weighted imaging was also done in three patients. Results and conclusions. MRI of pubic parasymphyseal insufficiency fracture characteristically demonstrates a hyperintense mass lesion with a hypointense rim on T2-weighted imaging, showing peripheral and septal enhancement after contrast administration. It is important to have this entity in mind in patients with osteoporosis, especially in patients with a history of pelvic irradiation for malignant disease, so as not to misinterpret it as a chondroid tumor or bone metastasis. (orig.). With 2 figs., 2 tabs.

  18. Tape dig selv!

    DEFF Research Database (Denmark)

    Andersen, Bente Annie Sørine; Neergaard, Christian; Seest, Kristian

    Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives......Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives...

  19. Retropubic cartilaginous cyst presenting as stress urinary incontinence

    DEFF Research Database (Denmark)

    Elmelund, Marlene; Thind, Peter; Klarskov, Niels

    2015-01-01

    A pubic cartilaginous cyst is a rare condition and is considered a result of degenerative changes in the symphysis pubis, mainly described in elderly multiparous women. There are only a few reported cases in the literature, and patients presented most frequently with a painful vaginal/vulvar mass....... This case report is the first to describe a patient with rapidly progressing stress urinary incontinence (SUI) due to a retropubic cartilaginous cyst. The patient in this case underwent surgical intervention; symptoms improved postoperatively, suggesting that surgical intervention in symptomatic patients...

  20. Sagittal crest formation in great apes and gibbons

    OpenAIRE

    Balolia, K. L.; Soligo, C.; Wood, B.

    2017-01-01

    The frequency of sagittal crest expression and patterns of sagittal crest growth and development have been documented in hominoids, including some extinct hominin taxa, and the more frequent expression of the sagittal crest in males has been traditionally linked with the need for larger-bodied individuals to have enough attachment area for the temporalis muscle. In the present study, we investigate sagittal cresting in a dentally mature sample of four hominoid taxa (Pan troglodytes schweinfur...

  1. Analysis of sagittal spinopelvic parameters in achondroplasia.

    Science.gov (United States)

    Hong, Jae-Young; Suh, Seung-Woo; Modi, Hitesh N; Park, Jong-Woong; Park, Jung-Ho

    2011-08-15

    Prospective radiological analysis of patients with achondroplasia. To analyze sagittal spinal alignment and pelvic orientation in achondroplasia patients. Knowledge of sagittal spinopelvic parameters is important for the treatment of achondroplasia, because they differ from those of the normal population and can induce pain. The study and control groups were composed of 32 achondroplasia patients and 24 healthy volunteers, respectively. All underwent lateral radiography of the whole spine including hip joints. The radiographic parameters examined were sacral slope (SS), pelvic tilt, pelvic incidence (PI), S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis (LL1, LL2), and sagittal balance. Statistical analysis was performed to identify significant differences between the two groups. In addition, correlations between parameters and symptoms were sought. Sagittal spinopelvic parameters, namely, pelvic tilt, pelvic incidence, S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis 1 and sagittal balance were found to be significantly different in the patient and control groups (P achondroplasia patients and normal healthy controls. The present study shows that sagittal spinal and pelvic parameters can assist the treatment of spinal disorders in achondroplasia patients.

  2. Effect of kinesiotaping, non-elastic taping and bracing on segmental foot kinematics during drop landing in healthy subjects and subjects with chronic ankle instability.

    Science.gov (United States)

    Kuni, B; Mussler, J; Kalkum, E; Schmitt, H; Wolf, S I

    2016-09-01

    To evaluate the effects of kinesiotape, non-elastic tape, and soft brace on segmental foot kinematics during drop landing in subjects with chronic ankle instability and healthy subjects. Controlled study with repeated measurements. Three-dimensional motion analysis laboratory. Twenty participants with chronic ankle instability and 20 healthy subjects. The subjects performed drop landings with 17 retroreflective markers on the foot and lower leg in four conditions: barefoot, with kinesiotape, with non-elastic tape and with a soft brace. Ranges of motion of foot segments using a foot measurement method. In participants with chronic ankle instability, midfoot movement in the frontal plane (inclination of the medial arch) was reduced significantly by non-elastic taping, but kinesiotaping and bracing had no effect. In healthy subjects, both non-elastic taping and bracing reduced that movement. In both groups, non-elastic taping and bracing reduced rearfoot excursion in inversion/eversion significantly, which indicates a stabilisation effect. No such effect was found with kinesiotaping. All three methods reduced maximum plantar flexion significantly. Non-elastic taping stabilised the midfoot best in patients with chronic ankle instability, while kinesiotaping did not influence foot kinematics other than to stabilise the rearfoot in the sagittal plane. ClinicalTrials.gov NCT01810471. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  3. Assessment of the mandibular symphysis of Caucasian Brazilian adults with well-balanced faces and normal occlusion: the influence of gender and facial type

    Directory of Open Access Journals (Sweden)

    Karine Evangelista Martins Arruda

    2012-06-01

    Full Text Available OBJECTIVE: This study aimed to establish cephalometric reference values for mandibular symphysis in adults. Dentoalveolar, skeletal and soft tissue variables were measured considering the influence of gender and facial type. METHODS: The sample consisted of sixty cephalometric radiographs of white Brazilian adult patients, with a mean age of 27 years and 6 months, who had not undergone orthodontic treatment and who presented well-balanced faces and normal occlusion. The sample was standardized according to gender (30 males and 30 females and facial type (20 were dolichofacial, 20 mesofacial and 20 brachyfacial. RESULTS: The results showed that male and female symphyses are similar, except for symphyseal height, which was greater in males. In terms of facial type, the dolichofacial group presented narrower symphysis in dentoalveolar and basal areas, with a more accentuated lingual dentoalveolar inclination. CONCLUSION: The brachyfacial group showed broader symphysis in the dentoalveolar and basal areas and a greater buccal dentoalveolar inclination. The projection of the chin was 6.67 mm below the subnasal vertical line and there was no significant difference between the genders or facial types.

  4. A test of Hartnett's revisions to the pubic symphysis and fourth rib methods on a modern sample.

    Science.gov (United States)

    Merritt, Catherine E

    2014-05-01

    Estimating age at death is one of the most important aspects of creating a biological profile. Most adult age estimation methods were developed on North American skeletal collections from the early to mid-20th century, and their applicability to modern populations has been questioned. In 2010, Hartnett used a modern skeletal collection from the Maricopia County Forensic Science Centre to revise the Suchey-Brooks pubic symphysis method and the İşcan et al. fourth rib methods. The current study tests Hartnett's revised methods as well as the original Suchey-Brooks and İşcan et al. methods on a modern sample from the William Bass Skeletal Collection (N = 313, mean age = 58.5, range 19-92). Results show that the Suchey-Brooks and İşcan et al. methods assign individuals to the correct phase 70.8% and 57.5% of the time compared with Hartnett's revised methods at 58.1% and 29.7%, respectively, with correctness scores based on one standard deviation of the mean rather than the entire age range. Accuracy and bias scores are significantly improved for Hartnett's revised pubic symphysis method and marginally better for Hartnett's revised fourth rib method, suggesting that the revised mean ages at death of Hartnett's phases better reflect this modern population. Overall, both Hartnett's revised methods are reliable age estimation methods. For the pubic symphysis, there are significant improvements in accuracy and bias scores, especially for older individuals; however, for the fourth rib, the results are comparable to the original İşcan et al. methods, with some improvement for older individuals. © 2014 American Academy of Forensic Sciences.

  5. Chin Symphysis Bone, Allograft, and Platelet-Rich Fibrin: Is the Combination Effective in Repair of Alveolar Cleft?

    Science.gov (United States)

    Movahedian Attar, Bijan; Naghdi, Navid; Etemadi Sh, Milad; Mehdizadeh, Mojdeh

    2017-05-01

    Secondary grafting of alveolar defects with iliac crest bone is a common treatment method in cleft patients. The aim of this study was to evaluate the effectiveness of the combination of symphysis bone, allograft, and platelet-rich fibrin in regeneration of alveolar defects compared with iliac bone graft. In this randomized clinical trial, patients with unilateral alveolar defects were divided randomly into two categories. Group A comprised patients in whom the combination of chin symphysis bone plus allogeneic bone material plus leukocyte- and platelet-rich fibrin was considered for treatment. Group B comprised patients in whom iliac bone graft was considered. Cone beam computed tomography before treatment and 1 year postoperatively was used for measurement of bone formation (bone volume in cubic centimeters). The data were analyzed by paired t and χ 2 tests via SPSS software (version 23; IBM, Armonk, NY). P platelet-rich fibrin is a proper combination for bone regeneration in alveolar defects with a small to moderate volume range. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Comprehensive Analysis of Mandibular Residual Asymmetry after Bilateral Sagittal Split Ramus Osteotomy Correction of Menton Point Deviation.

    Science.gov (United States)

    Lin, Han; Zhu, Ping; Lin, Qiuping; Huang, Xiaoqiong; Xu, Yue; Yang, Xiaoping

    2016-01-01

    Facial asymmetry often persists even after mandibular deviation corrected by the bilateral sagittal split ramus osteotomy (BSSRO) operation, since the reference facial sagittal plane for the asymmetry analysis is usually set up before the mandibular menton (Me) point correction. Our aim is to develop a predictive and quantitative method to assess the true asymmetry of the mandible after a midline correction performed by a virtual BSSRO, and to verify its availability by evaluation of the post-surgical improvement. A retrospective cohort study was conducted at the Hospital of Stomatology, Sun Yat-sen University (China) of patients with pure hemi-mandibular elongation (HE) from September 2010 through May 2014. Mandibular models were reconstructed from CBCT images of patients with pre-surgical orthodontic treatment. After mandibular de-rotation and midline alignment with virtual BSSRO, the elongation hemi-mandible was virtually mirrored along the facial sagittal plane. The residual asymmetry, defined as the superimposition and boolean operation of the mirrored elongation side on the normal side, was calculated, including the volumetric differences and the length of transversal and vertical asymmetry discrepancy. For more specific evaluation, both sides of the hemi-mandible were divided into the symphysis and parasymphysis (SP), mandibular body (MB), and mandibular angle (MA) regions. Other clinical variables include deviation of Me point, dental midline and molar relationship. The measurement of volumetric discrepancy between the two sides of post-surgical hemi-mandible were also calculated to verify the availability of virtual surgery. Paired t-tests were computed and the P value was set at .05. This study included 45 patients. The volume differences were 407.8±64.8 mm3, 2139.1±72.5 mm3, and 422.5±36.9 mm3; residual average transversal discrepancy, 1.9 mm, 1.0 mm, and 2.2 mm; average vertical discrepancy, 1.1 mm, 2.2 mm, and 2.2 mm (before virtual surgery). The

  7. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Chihaya, E-mail: chihaya.kurihara@jp.fujikura.com [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka [Kyushu University, 744 Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan)

    2016-11-15

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I{sub c} measurement, we found that our new multi-filamentary tape could provide almost equal I{sub c} compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  8. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    International Nuclear Information System (INIS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-01-01

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I_c measurement, we found that our new multi-filamentary tape could provide almost equal I_c compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  9. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  10. Enhancing the low-level tape layer of CERN Tape Archive software

    CERN Document Server

    AUTHOR|(CDS)2160814; Ruse, Laura Cristina; Vasilescu, Laura

    CERN manages the largest scientific data archive in the HEP domain. The archive currently holds over 180 Petabytes, with forecasts of up to 100PB of new data added per year. Considering this numbers, the most cost-effective solution for storage in terms of capacity and maintenance is represented by magnetic tapes. The drawback of this solution is the access time which can raise to several minutes for a series of files. In an environment where very large volumes of physics data are being traded from tape to disk and vice versa, this issue becomes a serious performance bottleneck. This thesis introduces two low-level tape access optimizations: first, adding support for the Recommended Access Order (RAO), a mechanism offered by the tape hardware infrastructure to compute the file order corresponding to the minimum access time. We will present our solution for including RAO in the file retrieval operations in CERN tape archive software in order to benefit from the reduced reading time. The second optimization ...

  11. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  12. The usefulness of sagittal reformation for diagnosis of sternal fracture

    Energy Technology Data Exchange (ETDEWEB)

    Im, Dong Jin; Hahn, Seok; Kim, Young Ju [Dept. of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2014-01-15

    The purpose of our study was to evaluate the usefulness of sagittal reformation of chest computed tomography for the diagnosis of sternal fracture after trauma. We retrospectively reviewed medical records and chest computer tomography (CT) of 716 patients in the emergency department after trauma between January and December 2010. Two radiologists investigated chest CT images. We investigated numbers and locations of sternal fractures on axial images only and on both axial and sagittal images for each radiologist. First, radiologist found sternal fractures in 58 patients (70.7%) on only axial images, and 80 (97.5%) on both axial and sagittal images. Second, radiologist found fractures in 67 patients (81.7%) on axial image only and 81 (98.7%) on both axial and sagittal images. The sensitivity increased after adding sagittal reformation images for each radiologist (p < 0.05, respectively). On the axial images, the interobserver agreement was low (k 0.596) between the two radiologists. However, on both axial and sagittal images, the interobserver agreement increased (k = 0.872). Sagittal reformation of chest CT increases the chance of diagnosis for sternal fracture and leads to early diagnosis resulting in appropriate treatment.

  13. The usefulness of sagittal reformation for diagnosis of sternal fracture

    International Nuclear Information System (INIS)

    Im, Dong Jin; Hahn, Seok; Kim, Young Ju

    2014-01-01

    The purpose of our study was to evaluate the usefulness of sagittal reformation of chest computed tomography for the diagnosis of sternal fracture after trauma. We retrospectively reviewed medical records and chest computer tomography (CT) of 716 patients in the emergency department after trauma between January and December 2010. Two radiologists investigated chest CT images. We investigated numbers and locations of sternal fractures on axial images only and on both axial and sagittal images for each radiologist. First, radiologist found sternal fractures in 58 patients (70.7%) on only axial images, and 80 (97.5%) on both axial and sagittal images. Second, radiologist found fractures in 67 patients (81.7%) on axial image only and 81 (98.7%) on both axial and sagittal images. The sensitivity increased after adding sagittal reformation images for each radiologist (p < 0.05, respectively). On the axial images, the interobserver agreement was low (k 0.596) between the two radiologists. However, on both axial and sagittal images, the interobserver agreement increased (k = 0.872). Sagittal reformation of chest CT increases the chance of diagnosis for sternal fracture and leads to early diagnosis resulting in appropriate treatment.

  14. Why the long face? The mechanics of mandibular symphysis proportions in crocodiles.

    Directory of Open Access Journals (Sweden)

    Christopher W Walmsley

    Full Text Available BACKGROUND: Crocodilians exhibit a spectrum of rostral shape from long snouted (longirostrine, through to short snouted (brevirostrine morphologies. The proportional length of the mandibular symphysis correlates consistently with rostral shape, forming as much as 50% of the mandible's length in longirostrine forms, but 10% in brevirostrine crocodilians. Here we analyse the structural consequences of an elongate mandibular symphysis in relation to feeding behaviours. METHODS/PRINCIPAL FINDINGS: Simple beam and high resolution Finite Element (FE models of seven species of crocodile were analysed under loads simulating biting, shaking and twisting. Using beam theory, we statistically compared multiple hypotheses of which morphological variables should control the biomechanical response. Brevi- and mesorostrine morphologies were found to consistently outperform longirostrine types when subject to equivalent biting, shaking and twisting loads. The best predictors of performance for biting and twisting loads in FE models were overall length and symphyseal length respectively; for shaking loads symphyseal length and a multivariate measurement of shape (PC1- which is strongly but not exclusively correlated with symphyseal length were equally good predictors. Linear measurements were better predictors than multivariate measurements of shape in biting and twisting loads. For both biting and shaking loads but not for twisting, simple beam models agree with best performance predictors in FE models. CONCLUSIONS/SIGNIFICANCE: Combining beam and FE modelling allows a priori hypotheses about the importance of morphological traits on biomechanics to be statistically tested. Short mandibular symphyses perform well under loads used for feeding upon large prey, but elongate symphyses incur high strains under equivalent loads, underlining the structural constraints to prey size in the longirostrine morphotype. The biomechanics of the crocodilian mandible are largely

  15. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15?h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ank...

  16. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    Science.gov (United States)

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  17. Perineal ultrasonography in women with stress-incontinence and controls - the role of the pelvic floor muscles

    NARCIS (Netherlands)

    WIJMA, J; TINGA, DJ; VISSER, GHA

    1991-01-01

    With a curved array real-time ultrasound scanning machine and the probe placed sagittally onto the vulva, symphysis, bladder, urethra and the pelvic floor can be visualized in one frame. With this technique we studied 10 women with stress incontinence and 10 control women. In both groups active

  18. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    Science.gov (United States)

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Comparative adequecy of colpocystourethrorectography and transrectal sonography in female urinary incontinence

    International Nuclear Information System (INIS)

    Braccini, G.; Pannocchia, P.; Alderigi, L.; Gigoni, R.; Calderazzi, A.

    1991-01-01

    In order to investigate the diagnostic reliability of transrectal US in the study of female urinary incontinence, the authors compared the static images obtained by means of colpocystourethrorectography with the ones obtained with transrectal US. The study population included 30 patients suffering from urinary incontinence. US images were obtained both at rest and during Valsalva's maneuver, some minutes before cystourethrography and employing part of its preparation (vesical filling with 250 cc of iodine contrast medium and positioning of a metallic bead chain in the urethra). On static images obtained with cystourethrography and transrectal US both at rest and during Valsalva, 4 parameters were evaluated: anterior and posterior vesical angles, urethral axis angle, and distance between symphysis pubis and urethral-vesical junction. As for posterior vesical angle, urethral axis angle, and symphysis-junction distance, the statistical comparison of the results did non demonstrate any significant differences. Anterior vesical angle was not included because it is too difficult to measure by transrectal US. In our experience, transrectal US was capable of yielding accurate information similar to that obtained with colpocystourethrorectography. 25 refs

  20. Acute proximal junctional failure in patients with preoperative sagittal imbalance.

    Science.gov (United States)

    Smith, Micah W; Annis, Prokopis; Lawrence, Brandon D; Daubs, Michael D; Brodke, Darrel S

    2015-10-01

    Proximal junctional failure (PJF) is a recognized complication of spinal deformity surgery. Acute PJF (APJF) has recently been demonstrated to be 5.6% in the adult spinal deformity (ASD) population. The incidence and rate of return to the operating room for APJF have not been specifically investigated in individuals with sagittal imbalance. The purpose of this study was to report the incidence of APJF in patients with preoperative sagittal imbalance and the rate of return to the operating room for APJF. This study is based on a retrospective review of prospectively collected database of ASD patients. One hundred seventy-three consecutive patients were included with preoperative sagittal imbalance according to one of the following common parameters: sagittal vertical axis (SVA) greater than 50 mm, global sagittal alignment greater than 45°, or pelvic incidence minus lumbar lordosis greater than 10°. Outcome measure was presence and/or absence of APJF defined as fracture at the upper instrumented vertebra (UIV) or UIV+1, failure of UIV fixation, 15° or more proximal junctional kyphosis, or need for extension of instrumentation within 6 months of surgery. We performed radiographic measurements on X-rays at preoperative, immediate postoperative, and 6-month follow-up visits. The APJF rate was reported for the entire patient population with preoperative sagittal imbalance. Acute PJF incidence was calculated postoperatively for each of the accepted sagittal balance parameters and/or formulas. Patients with persistent postoperative sagittal imbalance were compared with the sagittally balanced group. We also assessed for threshold values. Acute PJF was observed in 60 of 173 patients (35%) and was least common in fusions with the UIV in the upper thoracic (UT) spine (p=.035). Of those who developed APJF, 21.7% required surgery. Proximal junctional kyphosis 15° or more was the most common form of APJF in fusions to the UT spine but least likely to need revision (p=.014

  1. FUNCTIONAL DISABILITY, SAGITTAL ALIGNMENT AND PELVIC BALANCE IN LUMBAR SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Luis Muñiz Luna

    2016-03-01

    Full Text Available ABSTRACT Objectives: To demonstrate the recovery of lumbar sagittal pelvic alignment and sagittal pelvic balance after surgical reduction of lumbar spondylolisthesis and establish the benefits of the surgery for reduction and fixation of the lumbar spondylolisthesis with 360o circumferential arthrodesis for 2 surgical approaches by clinical and functional evaluation. Method: Eight patients with lumbar spondylolisthesis treated with surgical reduction and fixation of listhesis and segmental circumferential fusion with two surgical approaches were reviewed. They were evaluated before and after treatment with Oswestry, Visual Analogue for pain and Odom scales, performing radiographic measurement of lumbar sagittal alignment and pelvic sagittal balance with the technique of pelvic radius. Results: Oswestry scales and EVA reported improvement of symptoms after treatment in 8 cases; the Odom scale had six outstanding cases reported. The lumbar sagittal alignment presented a lumbosacral lordosis angle and a lumbopelvic lordosis angle reduced in 4 cases and increased in 4 other cases; pelvic sagittal balance increased the pelvic angle in 4 cases and decreased in 3 cases and the sacral translation of the hip axis to the promontory increased in 6 cases. Conclusion: The surgical procedure evaluated proved to be useful by modifying the lumbar sagittal alignment and the pelvic balance, besides reducing the symptoms, enabling the patient to have mobility and movement and the consequent satisfaction with the surgery.

  2. EFFECT OF KINESIO TAPE VERSUS ATHLETIC TAPE ON MYOELECTRIC ACTIVITY OF ANKLE MUSCLES IN PATIENTS WITH CHRONIC ANKLE SPRAIN

    Directory of Open Access Journals (Sweden)

    Asmaa F Abdelmonem

    2018-04-01

    Full Text Available Background: Sprained ankle a common orthopedic injury. The standard treatment for ankle sprains remains nonoperative. Ankle taping was used to protect and prevent ligaments excessive strain. So, the current study aimed at investigating the effect of spa-care Kinesio tape versus standard white athletic tape on myoelectric activities (EMG of ankle evertors (peroneus longus and invertors (tibialis anterior in a chronic ankle sprain. Methods: A convenient sample of 30 patients with a chronic ankle sprain (18 females and 12 males were included in this study. Their mean age ±SD was 24 ±1.2 years. Their height was 175±4.8 cm among men & 163±5.2 cm for females, and weight was 85±5.2 kg for males & 74±5.5 kg for women. It was a within-group design in which the same participant experienced the two types of taping compared to no taping condition. Root mean square (RMS was measured while participants were moving the isokinetic dynamometer at an angular velocity of 120°/sec using concentric contraction mode through full ankle range of motion. The EMG (RMS of evertors and invertors was measured immediately after the three taping ways (no tape, Kinesio tape, and athletic tape with a one-week interval between each taping. Results: Spa-care Kinesiotape significantly reduced evertors and invertors EMG (RMS compared with no tape or athletic tape in patients with chronic ankle sprain. Mean± SD of the evertors was 0.7 (±0.1 for no tape and 0.58 (±0.2 for Kinesio tape. The P value was 0.000 for kinesio tape in evertors compared with no tape. Also, mean± SD of the invertors was 0.87 (±0.23 for no tape, and 0.54 (±0.1 for Kinesio tape and the P value was 0.001 for Kinesio tape in invertors compared with no tape. Conclusion: Spa-care Kinesio tape may be useful for reducing EMG activity of ankle muscles in a chronic ankle sprain.

  3. Flow structure and heat transfer in a square duct fitted with dual/quadruple twisted-tapes: Influence of tape configuration

    International Nuclear Information System (INIS)

    Eiamsa-ard, S.; Changcharoen, W.

    2015-01-01

    Numerical predictions reported of thermohydraulic characteristics of square ducts equipped with dual and quadruple twisted tapes (DTs and QTs) with different configurations. The studied cases include (1) dual co-tapes (Co-DTs), (2) dual counter-tapes (C-DTs), (3) diagonal dual counter-tapes (C-DDTs), (4) diagonal dual co-tapes (Co-DDTs), (5) quadruple co-tapes (Co-QTs), (6) quadruple counter tapes (CC-QTs) and (7) quadruple counter-tapes (PC-QTs). The results of these cases are compared with those of a smooth duct (a duct without tape insert) and also the one with a single tape (ST). The prediction involves using the RNG k-ε turbulent model under constant wall heat flux condition in the turbulent flow regime for the Reynolds number ranging from 6000 to 14000. The prediction indicates that thermohydraulic characteristics in ducts with twisted tape are strongly dependent on number and configuration of tapes. However, the influence of tape number is more significant than that of tape configuration. Heat transfer and friction increase as tape number increases. QTs offer superior heat transfer to DTs but their thermal performance factors are lower. For the tape inserts determined, DTs with diagonal configuration (Co-DDTs and C-DDTs) is the best design as the tapes offer the best thermal performance. The highest thermal performance factors given by Co-DTs, Co-DDTs, C-DTs, C-DDTs, Co-QTs, PC-QTs and CC-QTs, are around 1.21, 1.35, 1.25, 1.38, 1.08, 1.18, and 1.22, respectively

  4. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  5. Tape write-efficiency improvements in CASTOR

    International Nuclear Information System (INIS)

    Murray, S; Bahyl, V; Cancio, G; Cano, E; Lo Presti, G; Lo Re, G; Ponce, S; Kotlyar, V

    2012-01-01

    The CERN Advanced STORage manager (CASTOR) is used to archive to tape the physics data of past and present physics experiments. For reasons of physical storage space, all of the tape resident data in CASTOR are repacked onto higher density tapes approximately every two years. Improving the performance of writing files smaller than 2GB to tape is essential in order to keep the time needed to repack all of the tape resident data within a period of no more than 1 year. This paper reports on the solution to writing efficiently to tape that is currently in its early deployment phases at CERN.

  6. Paper Punch Tape

    CERN Multimedia

    Physicists coded and recorded their programs through series of holes on punch paper tape or on punched cards. It was popular in the 1970s due to its high throughput speed and low cost, paper tape was one of the original data storage methods for computers. Information was encoded in the distinct pattern of holes punched in the paper; the paper itself was oiled to facilitate being run through the reading mechanism and to prevent tears due to brittleness. Though the paper was cheap, it had low storage capacity (only a few dozen kilobytes per roll) and the machinery involved in punching the holes was quite expensive. Higher capacity alternatives, such as magnetic tape, has get developped.

  7. Award of two contracts for the renting of magnetic tape drives and tape libraries for LHC data storage and the purchase of the associated tape cartridges

    CERN Document Server

    2005-01-01

    This document concerns the award of two contracts for the renting and possible subsequent purchase of magnetic tape drives and tape libraries for LHC data storage. The Finance Committee is invited to agree to the procedure described in section 3 of this document for the evaluation and possible subsequent purchase of tape drives and tape libraries for the storage of data from the LHC experiments. Subject to approval of this procedure, the Finance Committee is further invited to approve the negotiation of a contract for the renting of tape drives and tape libraries for evaluation purposes from IBM, for an amount of 579 707 Swiss francs, and from StorageTek, for an amount of 472 297 Swiss francs, during the period January 2006 â?" March 2007, plus the purchase of the associated tape cartridges for amounts of 202 500 Swiss francs and 284 748 Swiss francs respectively. The Finance Committee will be informed of the results of the evaluation by the end of 2006 and, subject to the outcome, will be invited to approve...

  8. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Wen-Dien Chang

    2015-01-01

    Full Text Available Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS. Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life.

  9. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    Directory of Open Access Journals (Sweden)

    Biju Chetri

    2016-04-01

    Full Text Available Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected. The subjects were randomly divided into two groups i.e. Group A and Group B. Group A received taping, iontophoresis with plantar fascia stretching. Group B received taping and plantar fascia stretching. A total of 6 treatment sessions were given on alternate days over a period of two weeks for both the groups. Results: VAS and FFI scores across baseline and post intervention showed a significant improvement statistically in their mean scores between Groups A and B (P<0.05. Between group comparison of VAS and FFI scores, it showed that subject treated with Iontophoresis in combination with taping and plantar fascia stretch (Group A had significant improvement in VAS and functional ability when compared to subjects treated with taping and plantar fascia stretching alone (Group B. Conclusion: Iontophoresis along with Taping and plantar fascia stretching gave an additional benefit when compared with Taping and plantar fascia stretching alone in reducing pain and improving function in plantar fasciitis.

  10. Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Azoulay, Robin; Sebag, Guy; Mazda, Keyvan

    2013-06-01

    Radiological reproducibility study. To assess intra and interobserver reliability of radiographic measurements for global sagittal balance parameters and sagittal spine curves, including cervical spine. Sagittal spine balance in adolescent idiopathic scoliosis (AIS) is a main issue and many studies have been reported, showing that coronal and sagittal deformities often involve sagittal cervical unbalance. Global sagittal balance aims to obtain a horizontal gaze and gravity line at top of hips when subject is in a static position, involving adjustment of each spine curvature in the sagittal plane. To our knowledge, no study did use a methodologically validated imaging analysis tool able to appreciate sagittal spine contours and distances in AIS and especially in the cervical region. Lateral full-spine low-dose EOS radiographs were performed in 75 patients divided in three groups (control subjects, AIS, operated AIS). Three observers digitally analyzed twice each radiograph and 11 sagittal measures were collected for each image. Reliability was assessed calculating intraobserver Pearson's r correlation coefficient, interobserver intra-class correlation coefficient (ICC) completed with a two-by-two Bland-Altman plot analysis. This measurement method has shown excellent intra and interobserver reliability in all parameters, sagittal curvatures, pelvic parameters and global sagittal balance. This study validated a simple and efficient tool in AIS sagittal contour analysis. It defined new relevant landmarks allowing to characterize cervical segmental curvatures and cervical involvement in global balance.

  11. Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience.

    Science.gov (United States)

    Yu, Ke-He; Hong, Jian-Jun; Guo, Xiao-Shan; Zhou, Dong-Sheng

    2015-09-22

    The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18-54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.

  12. Back to the future: sagittal CT in the evaluation of COPD

    International Nuclear Information System (INIS)

    Hightower, Jessica S.; Amadi, Chiemezie; Den, Elana; Schmitt, James E.; Shah, Rosita M.; Miller, Wallace T.

    2016-01-01

    To identify features of obstructive airway disease on sagittal reconstruction, compare the accuracy of findings to traditional imaging characteristics of COPD, and determine the fraction of additional cases identified using new characteristics. The study was approved by the centre's Institutional Review Board and is HIPAA compliant. Two hundred sixteen patients with HRCT and spirometry within a 3-month window were included. Four radiologists evaluated each HRCT for traditional characteristics of COPD and new quantitative and qualitative features of obstruction on axial and sagittal reconstructions. Imaging characteristics were assessed for correlation with the spirometric diagnosis of obstructive airway disease. Quantitative and qualitative findings on sagittal reconstruction are highly specific for COPD (specificity >90 %). Features of hyperinflation on sagittal reconstruction are more accurate predictors of obstruction than traditional axial measures, with greater interobserver reliability (hyperinflation left hemidiaphragm: accuracy: 70.08 % ± 2.49 %; kappa: 0.511 versus traditional measures: accuracy: 62.00 % ± 5.38 %; kappa: 0.407). Sagittal reconstruction identified 27-70 % more patients with COPD than traditional axial findings (p < 0.05). Analysis of sagittal reconstruction enables greater accuracy and specificity in the diagnosis of obstructive airway disease compared to traditional measures on axial imaging. Use of sagittal reconstructions can help identify up to 70 % more patients with COPD than traditional imaging findings alone. (orig.)

  13. The mandibular symphysis as a starting point for the occlusal-level reconstruction of panfacial fractures with bicondylar fractures and interruption of the maxillary and mandibular arches: report of two cases.

    Science.gov (United States)

    Pau, Mauro; Reinbacher, Knut Ernst; Feichtinger, Matthias; Navysany, Kawe; Kärcher, Hans

    2014-06-01

    Panfacial fractures represent a challenge, even for experienced maxillofacial surgeons, because all references for reconstructing the facial skeleton are missing. Logical reconstructive sequencing based on a clear understanding of the correlation between projection and the widths and lengths of facial subunits should enable the surgeon to achieve correct realignment of the bony framework of the face and to prevent late deformity and functional impairment. Reconstruction is particularly challenging in patients presenting with concomitant fractures at the Le Fort I level and affecting the palate, condyles, and mandibular symphysis. In cases without bony loss and sufficient dentition, we believe that accurate fixation of the mandibular symphysis can represent the starting point of a reconstructive sequence that allows successful reconstruction at the Le Fort I level. Two patients were treated in our department by reconstruction starting in the occlusal area through repair of the mandibular symphysis. Both patients considered the postoperative facial shape and profile to be satisfactory and comparable to the pre-injury situation. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Anthropometric outcome of sagittal craniosynostosis following surgery

    International Nuclear Information System (INIS)

    Takagi, Toshinori; Morota, Nobuhito; Ihara, Satoshi; Kaneko, Tsuyoshi

    2011-01-01

    Several studies have shown good short-term outcomes after surgery for sagittal synostosis. However, the improvement in head shape usually regresses over the long term. The aim of this study was to compare anthropometric changes after surgery between osteoplastic expansion surgery and distraction osteogenesis for correcting sagittal synostosis. From November 2002 through December 2008, 17 patients with sagittal synostosis were analyzed. Anthropometric changes were assessed with cephalic indices obtained with computed tomography of the skull. The age of the patients at the time of surgery ranged from 2 to 25 months (mean, 8.2 months), and the follow-up period ranged from 6 to 63 months (mean, 17 months). In 16 patients, the cephalic index showed improvement immediately after surgery but gradually decreased in the follow-up period. The improving rate was decreased more after osteoplastic expansion surgery than after distraction osteogenesis (p<0.01). Although long-term follow-up is necessary, morphological improvement persists to a greater degree after distraction surgery. (author)

  15. Pedicle subtraction osteotomy in elderly patients with degenerative sagittal imbalance.

    Science.gov (United States)

    Cho, Kyu-Jung; Kim, Ki-Tack; Kim, Whoan-Jeang; Lee, Sang-Hoon; Jung, Jae-Hoon; Kim, Young-Tae; Park, Hae-Bong

    2013-11-15

    Retrospective, radiographical analysis. To evaluate pedicle subtraction osteotomy (PSO) as a means of correcting severe degenerative sagittal imbalance in elderly patients. PSO in patients with degenerative sagittal imbalance is likely to cause more complications than in patients with iatrogenic flatback deformity. This study analyzed 34 patients who underwent fusion to the sacrum, with a minimum 2-year follow-up. Age of the patients were in the range from 58 to 73 with the mean at 65.5 years. PSO was performed at one segment in all cases, consisting of L3 (n = 26), L4 (n = 4), L2 (n = 3), and L1 (n = 1). The average number of levels fused was 8.15. Ten patients had structural interbody fusion at the lumbosacral junction. Applying PSO at one segment, the mean correction of the lordotic angle at the osteotomy site was 33.3°, of which the loss of correction (LOC) was 4.0° at the last visit. The correction of lumbar lordosis was 33.7° and the LOC was 8.5°. The sagittal C7 plumb was 215.9 mm before surgery, corrected to 35.1 mm after surgery, and changed to 95.9 mm by the last visit. The correction of the sagittal C7 plumb was 119.9 mm and the LOC was 60.9 mm. There was substantial LOC in lumbar lordosis and sagittal C7 plumb. In 10 patients with addition of posterior lumbar interbody fusion, the LOC of lumbar lordosis was 7.4°, which was less than 9° in those without it. PSO for the correction of degenerative sagittal imbalance in elderly patients resulted in correction of sagittal alignment with a significant LOC of lumbar lordosis and sagittal C7 plumb. The LOC of lumbar lordosis occurred at both the osteotomy and non-osteotomy site. The addition of anterior column support is helpful to maintain correction and reduce complications. N/A.

  16. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the S...

  17. An enhanced computational method for age-at-death estimation based on the pubic symphysis using 3D laser scans and thin plate splines.

    Science.gov (United States)

    Stoyanova, Detelina; Algee-Hewitt, Bridget F B; Slice, Dennis E

    2015-11-01

    The pubic symphysis is frequently used to estimate age-at-death from the adult skeleton. Assessment methods require the visual comparison of the bone morphology against age-informative characteristics that represent a series of phases. Age-at-death is then estimated from the age-range previously associated with the chosen phase. While easily executed, the "morphoscopic" process of feature-scoring and bone-to-phase-matching is known to be subjective. Studies of method and practitioner error demonstrate a need for alternative tools to quantify age-progressive change in the pubic symphysis. This article proposes a more objective, quantitative method that analyzes three-dimensional (3D) surface scans of the pubic symphysis using a thin plate spline algorithm (TPS). This algorithm models the bending of a flat plane to approximately match the surface of the bone and minimizes the bending energy required for this transformation. Known age-at-death and bending energy were used to construct a linear model to predict age from observed bending energy. This approach is tested with scans from 44 documented white male skeletons and 12 casts. The results of the surface analysis show a significant association (regression p-value = 0.0002 and coefficient of determination = 0.2270) between the minimum bending energy and age-at-death, with a root mean square error of ≈19 years. This TPS method yields estimates comparable to established methods but offers a fully integrated, objective and quantitative framework of analysis and has potential for use in archaeological and forensic casework. © 2015 Wiley Periodicals, Inc.

  18. Walking sagittal balance correction by pedicle subtraction osteotomy in adults with fixed sagittal imbalance.

    Science.gov (United States)

    Yagi, Mitsuru; Kaneko, Shinjiro; Yato, Yoshiyuki; Asazuma, Takashi; Machida, Masafumi

    2016-08-01

    Pedicle subtraction osteotomy (PSO) is widely used to treat severe fixed sagittal imbalance. However, the effect of PSO on balance has not been fully documented. The aim of this study was to assess dynamic walking balance after PSO to treat fixed sagittal imbalance. Gait and balance were assessed in 15 consecutive adult female patients who had been treated by PSO for a fixed sagittal imbalance and compare patients' preop and postop dynamic walking balance with that of 15 age- and gender-matched healthy volunteers (HV). Each patient's chart, X-rays, pre and postop SRS22 outcome scores, and ODI were reviewed. Means were compared by Mann-Whitney U test and Chi-square test. The mean age was 66.3 years (51-74 years). The mean follow-up was 2.7 years (2-3.5 years). The C7PL and GL, measured on the force platform, were both improved from 24.2 ± 7.3 cm and 27.6 ± 9.4 to 5.4 ± 2.6 cm and 7.2 ± 3.4 cm, respectively. The baseline hip ROM was significantly smaller in patients compared to HV, whereas no significant difference was observed in the knee or ankle ROM. The pelvic tilt (preop -0.4° ± 1.4°, postop 8.9° ± 1.0°), and maximum hip-extension angle (preop -1.2° ± 14.2°, postop -11.2° ± 7.2°) were also improved after surgery. Cadence (116 s/min), stance-swing ratio (stance 63.2 % vs. swing 36.8 %), and stride (98.0 cm) were all increased after surgery. On the other hand, gait velocity was significantly slower in the PSO group at both pre and postop than in HV (PSO 53.3 m/min at preop and 58.8 m/min at postop vs. HV 71.1 m/min, p = 0.04). Despite a mild residual spinal-pelvic malalignment, PSO restored sagittal alignment and balance satisfactorily and has improved the gait pattern.

  19. Application for the Tape Station

    CERN Document Server

    Solero, A

    2003-01-01

    The Tape Station is used as an Isolde facility to observe the variations of intensity and the lifespan of certain isotopes. A Siemens Simatic FM-352-5 module controls the Tape Station in a PLC system then a DSC controls the PLC, which will be controlled the Tape station program. During the Isolde consolidation project, the Tape Station has been rebuilt, and the control system has been fully integrated in the PS control. Finally, a new application has been written in JAVA Development kit 1.4 and the PS Java environment. The main purpose of this note is to explain how to use this program.

  20. Effect of kinesio-taping on ankle joint stability

    Directory of Open Access Journals (Sweden)

    Mervat A. Mohamed

    2016-05-01

    Full Text Available Ankle Instability is characterized by recurrent giving way and often develops after repeated lateral ankle sprains. Kinesiotape is more elastic than traditional athletic tape and is becoming increasingly popular. It is reported to decrease pain, improve muscle function, circulation and proprioception, however, research examining the effects of Kinesiotape in ankle instability is limited. The objective of this study was to determine if applying Kinesiotape to unstable ankle may improve performance in the Star Excursion Balance Test (SEBT, which has been shown to be a sensitive and reliable measure for quantifying dynamic balance. Thirty subjects with first degree ankle sprain were participated in this study. SEBT was used to test the subject dynamic balance under three conditions; without taping, with white athletic tape and with kinesiotape. One way repeated measure ANOVA using Greenhouse-Geisser corrections were conducted to evaluate differences in SEBT for the three conditions. Pairwise comparison of the outcome measures in the three occasions (without taping, with athletic taping, and with kinesio taping revealed statistically significant differences of all outcomes between occasion 1 (without taping and occasion 2 (with athletic taping favoring the athletic taping (p < 0.05. Also, a statistically significant difference between occasion 1 (without taping and occasion 3 (with kinesio taping were found (p < 0.05 favoring kinesio taping. Moreover, pairwise comparison of the ankle stability outcomes using athletic taping versus kinesio taping indicated a statistically significant difference (p < 0.05 in favor of kinesio taping measures. Conclusion: kinesiotape has superior effect than athletic tape in patients with first degree ankle sprain and can be used safely for improving ankle joint stability.

  1. Traumatic Hemipelvectomy with Free Gluteus Maximus Fillet Flap Covers: A Case Report

    Directory of Open Access Journals (Sweden)

    WI Faisham

    2012-07-01

    Full Text Available threatening injury. We report a case of a 16-year-old boy involved in a traffic accident who presented with an almost circumferential pelvic wound with wide diastasis of the right sacroiliac joint and symphysis pubis. The injury was associated with complete avulsion of external and internal iliac vessels as well as the femoral and sciatic nerves. He also had ipsilateral open comminuted fractures of the femur and tibia. Emergency debridement and completion of amputation with preservation of the posterior gluteal flap and primary anastomosis of the inferior gluteal vessels to the internal iliac artery stump were performed. A free fillet flap was used to close the massive exposed area.

  2. The neutron beam users tape management system

    International Nuclear Information System (INIS)

    Lyall, B.; Johnson, M.W.

    1977-02-01

    Systems are described for dealing with data collected at the High Flux Reactor, Institut Laue-Langevin, Grenoble and brought on magnetic tape to the Neutron Beam Research Unit at the Rutherford Laboratory. The first system, named GNAT, was designed to archive the incoming 800 bpi tapes onto 6250 bpi tapes (to enable them to return to the ILL). The archiving program, besides choosing the archive tapes, keeping a record of the data sets archived, and writing the archive tape, should be able to cope with incoming tapes whose formats are somewhat different from the standard IBM format. The second system, named FONT, was designed to maintain a record of all the tapes in the NBRU's possession, their whereabouts and what data, if any, are on them. (U.K.)

  3. Tape Storage and CRC Protection

    CERN Document Server

    Ha, Karel

    2014-01-01

    Over 100 Petabytes of data is stored on several kind of physical support, namely disks and tapes. Data on any physical support or traveling on a data link (network, fibre channel...) can be subject to silent data corruption. A possible improvement is introducing end-to-end data integrity from the filesystem down to the tape layer. For the tape back-end it can be done by using Logical Block Protection, which computes and compares CRC checksum of every single block of data. During my work, I improved on-the-fly CRC calculation for the tape storage system, which was achieved by introducing a multithreaded implementation - a technique applicable to arbitrary CRC algorithm. Finally, I per...

  4. Lenke 1 and 5: changes in sagittal balance

    Directory of Open Access Journals (Sweden)

    Delson Valdemir Pessin

    2014-09-01

    Full Text Available OBJECTIVE: To assess in a cross-sectional study whether there are changes in sagittal balance in patients with adolescent idiopathic scoliosis Lenke types 1 and 5 compared with patients without pathology of the spine and compare the values of the parameters of normal subjects with the parameters found in the literature. METHODS: We measured the values of the parameters of sagittal balance of 21 patients with scoliosis and 14 patients without scoliosis in panoramic radiographs or simply collected data previously measured from the medical records. We compared the mean values of normal subjects, the mean values found in the literature, and the means between normal subjects and patients with scoliosis. For this, we used the Student t test. RESULTS: Using a confidence interval of 5% (p < 0.05 and the Student t test we obtained statistical significance in the comparison of two parameters of sagittal balance between normal subjects and patients with scoliosis. We observed similarities in the measurements of the average parameters of normal subjects with regard to the work already published. CONCLUSIONS: The adolescent idiopathic scoliosis causes changes in two parameters of sagittal balance with statistical significance but suggests changes in all other parameters. As for comparison with previously published work, the results were similar.

  5. Analisis Perilaku Konsumen Proll Tape di Jember

    OpenAIRE

    Kusmiati, Ati; Widjayanti, Lenny; Risaldi, Feri

    2009-01-01

    Proll tape is a agroindustrial product which used agriculture product as a basic material. It is a diversification product from tape and mixed with some flavour. It can be found in the gift store. Proll tape marketing strategic will influence consumer behaviour in the decision buying. Consumer buy proll tape as a gift as beside on their own consumption. Consumer considers proll tape has a good quality so that it can fill consumer needed. Purpose of the research to find out the influence facto...

  6. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  7. Spinal Schmorl's nodes: Sagittal sectional imaging and pathological examination

    International Nuclear Information System (INIS)

    Silberstein, M.; Opeskin, K.

    1999-01-01

    The presence, location and number of Schmorl's nodes was determined in the thoracolumbar spines of 70 motor vehicle accident victims using radiographic examination of a midline sagittal section and subsequent pathological examinations, including histology. In 28% of spines, a greater number of Schmorl's nodes were identified with radiography, while in 44%, pathological examination revealed a greater number of nodes. The visibility of Schmorl's nodes was enhanced by using a sagittal radiographic approach, and, in contrast to previous work, nodes below 0.5 cm 2 were readily detected. The results of the present study offer an additional imaging technique for postmortem analysis of the spine, and support the use of sagittal MR imaging for the evaluation of this condition. Copyright (1999) Blackwell Science Pty Ltd

  8. Caught (Unfortunately) on Tape

    Science.gov (United States)

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  9. HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

    International Nuclear Information System (INIS)

    Kang, Myung Hun; Ku, Myung Hwan; Cha, Guee Soo; Lim, Hyoung Woo

    2015-01-01

    The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively

  10. Tape casting fluorinated YBC123

    International Nuclear Information System (INIS)

    Taylor, J.A.T.; Luke, D.M.; Whiteley, B.A.

    1991-01-01

    Tape casting the superconducting Ba-Y-Cu oxide was accomplished by several laboratories and show promise for being a versatile forming technique. The major problem is low current density, probably due to lack of grain alignment and grain boundary related weak links. The latter problem may be due to formation of carbonates and hydroxides during binder burnout. Preliminary work done at Alfred shows that a bimodal powder size distribution displays significant alignment after tape casting and that F treated powder is resistant to attack by steam at 100C. Such corrosion resistant powder cast as form tape should survive the binder burnout without the detrimental grain boundary phases that develop from reaction of the superconducting phase, steam and carbon dioxide. This paper presents the results of an investigation of tape casting fluorinated powder with a bimodal size distribution

  11. Safety brake for tape reels

    Science.gov (United States)

    Carle, C. E.

    1977-01-01

    All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

  12. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    OpenAIRE

    Biju Chetri, U.T. Ifthikar Ali, Madhusmita Koch, Abhijit Dutta

    2016-01-01

    Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected...

  13. Influence of implant rod curvature on sagittal correction of scoliosis deformity.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2014-08-01

    Deformation of in vivo-implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. To analyze the changes of the implant rod's angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. Twenty adolescent idiopathic scoliosis patients underwent surgery. Average age at the time of operation was 14 years. The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. Two implant rods were attached to the concave and convex side of the spinal deformity. The preoperative implant rod geometry was measured before surgical implantation. The postoperative implant rod geometry after surgery was measured by computed tomography. The implant rod angle of curvature at the sagittal plane was obtained from the implant rod geometry. The angle of curvature between the implant rod extreme ends was measured before implantation and after surgery. The sagittal curvature between the corresponding spinal levels of healthy adolescents obtained by previous studies was compared with the implant rod angle of curvature to evaluate the sagittal curve correction. The difference between the postoperative implant rod angle of curvature and normal spine sagittal curvature of the corresponding instrumented level was used to evaluate over or under correction of the sagittal deformity. The implant rods at the concave side of deformity of all patients were significantly deformed after surgery. The average degree of rod deformation Δθ at the concave and convex sides was 15.8° and 1.6°, respectively. The average preoperative and postoperative implant rod angle of curvature at the concave side was 33.6° and 17.8

  14. Strategy for robot motion and path planning in robot taping

    Science.gov (United States)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  15. Centrally managed tapes at DESY

    International Nuclear Information System (INIS)

    Hell, O.

    1994-01-01

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years

  16. Tape-cast sensors and method of making

    Science.gov (United States)

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  17. Levitation characteristics of HTS tape stacks

    Energy Technology Data Exchange (ETDEWEB)

    Pokrovskiy, S. V.; Ermolaev, Y. S.; Rudnev, I. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-03-15

    Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing of tapes and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

  18. Traumatic hemipelvectomia in one year old girl. Report of case

    Directory of Open Access Journals (Sweden)

    Fernando Medina González

    2006-01-01

    Full Text Available The trauma of pelvis is a complex condition that implies injuries of vital organs putting in risk the life of the patient. The traumatic hemipelvectomy is a extremely severe pelvic injury and is fatal almost always, caused generally to events of high energy. It causes traumatic dislocation of the sacroiliac joint and the symphysis pubis, and to the femoral vessels are avulsioned. Because survival rate it is so low it require prompt medical attention. In this pathology type dissabling and prostetic wear is very difficult. In the medical literature there is not report of any patient ho survived this type of lesion under three year's old. We report a case of traumatic hemipelvectomy in a girl of 21 months who survived a traffic accident.

  19. Preparation and characterization of Bi-2223 tapes

    International Nuclear Information System (INIS)

    Hense, K.; Kirchmayr, H.; Kovac, P.; Lackner, R.; Mueller, M.; Pachla, W.; Pitel, J.; Polak, M.; Usak, P.

    2003-01-01

    In a concerted action between Austrian, Slovakian and Polish research institutes Bi-2223 tapes have been prepared and characterized by different physical methods. Metallographic studies by optical as well as electron microscopy, measurements of critical current (angle dependent) and losses have been performed. Properties of individual filaments extracted from multifilamentary tapes were also studied. Uniformity of local I C of these filaments were considerably lower than that of the whole tape. This indicates that improvement of filament homogeneity could improve the over all J C in tapes. The application of these tapes for optimized magnet coils will also be discussed. From these investigations a better understanding of the mechanisms, limiting the critical current could be achieved and more optimized preparation methods can be envisioned

  20. Superior sagittal sinus thrombosis: a rare complication of nephrotic syndrome.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1999-10-01

    Full Text Available A two and half year-old-male child, known case of steroid responsive nephrotic syndrome presented with fever and vomiting of acute onset. He was diagnosed to have superior sagittal sinus thrombosis on a contrast computerised tomographic scan of brain. Recovery was complete without anticoagulant therapy. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome.

  1. Reel-to-reel substrate tape polishing system

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  2. Ubiquitous Graphene Electronics on Scotch Tape

    Science.gov (United States)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  3. Reproduction of superior sagittal sinus animal model by bypass transplantation of biomaterial graft

    Directory of Open Access Journals (Sweden)

    Qing-yong LUO

    2011-03-01

    Full Text Available Objective To establish the beagles model of superior sagittal sinus bypass graft,and explore the feasibility of reconstruction of superior sagittal sinus with biomaterials using this model.Methods Eight adult male beagles(weight: 12.5-22.0kg were involved in the present study.The superior sagittal sinus was exposed and blocked via bone window,and then anastomosed side-to-end to the biomaterial graft under the dedicated microscope of neurosurgery surgery,expectant treatment such as anti-inflammatory was given for the animals.The digital subtraction venography(DSV and color Doppler flow imaging(CDFI of superior sagittal sinus were performed in 1,2,4 and 8 weeks after the operation.Eight weeks after the operation,all the animals were sacrificed and the material graft was examined histologically.Results The DSV and CDFI of superior sagittal sinus showed that the stomas of 2 beagles were with slight stenosis and high flow velocity,of 1 beagle with small leakage and low flow velocity,while of other 5 beagles were normal.The histological examination showed endothelial cells were growing on the graft and superior sagittal sinus,and crawling toward the lumen of graft 8 weeks after the operation.Conclusion The beagles model of superior sagittal sinus bypass graft was established successfully.The short-term effect of the model was satisfactory,while further work should be performed to determine the long-term effects.

  4. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  5. Design of double tape recorder data acquisition system

    International Nuclear Information System (INIS)

    Guo Tianrui; Du Yifei

    1995-01-01

    In the data acquisition system supported by the microcomputer tape recorder, as the acquisition speed is often limited by the low speed of tape recorder, so a double tape recorder system is designed. In this system, two tape recorders are used in on-line acquisition system simultaneously. One DMA channel used is one designed for soft disk driver, another DMA channel used is one retained for user. By this way, the speed of tape writing could be increased to nearly twice as much. In order to prevent the data confusion, the authors open two data buffers in system and write different mark in each buffer, then write the data block to two tape recorders according to the mark. The system complies with the principle: 'Double write, Double read'

  6. Diagnostics of sources of disturbances and distribution of vibrations over the width of a tape in tape-feed mechanisms

    Science.gov (United States)

    Kenstavichyus, A. B. B.

    1973-01-01

    Disturbances created by certain assemblies and components of tape-feed mechanisms (TFM) and acting on a moving magnetic tape are studied. The method, based on elements of digital logic, is established by stress-strain diagrams of the longitudinal deformations and vibrations across the width of a magnetic tape. Experimental studies were carried out for determination of the functional relationships of longitudinal deformations in a section of magnetic tape to the magnitude of roller play, tension vibrations rate of movement, and elasticity of magnetic tapes. A block diagram of the measurements is shown. Appropriate digital computer algorithms and programs were proposed for statistical analysis of the data obtained. Estimates of the mathematical expectation, dispersion, intercorrelation function, energy spectral density, and distribution pattern of the random process values were calculated.

  7. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  8. Mid-sagittal plane and mid-sagittal surface optimization in brain MRI using a local symmetry measure

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Skoglund, Karl; Ryberg, Charlotte

    2005-01-01

    , the mid-sagittal plane is not always planar, but a curved surface resulting in poor partitioning of the brain hemispheres. To account for this, this paper also investigates an optimization strategy which fits a thin-plate spline surface to the brain data using a robust least median of squares estimator...

  9. Tape SCSI monitoring and encryption at CERN

    Science.gov (United States)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  10. Sagittal synostosis in X-linked hypophosphatemic rickets and related diseases

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, Guido [Texas Scottish Rite Hospital, Department of Radiology, Dallas, TX (United States)

    2007-08-15

    The recent observations of two new cases of X-linked hypophosphatemic rickets associated with premature closure of the sagittal suture prompted a review of similar cases seen in this institution. To review the clinical records and skull radiographs of 28 children with hypophosphatemic rickets in order to investigate the frequency and type of craniosynostosis and other cranial vault changes seen in these conditions and to review the literature for relevant findings. Clinical and imaging records were reviewed on 28 patients with hypophosphatemic rickets, all younger than 18 years. Most patients had X-linked hypophosphatemic rickets and a few had autosomal-dominant hypophosphatemic rickets or were non-familial cases. Of the 28 patients, 13 had sagittal synostosis. Dolichocephaly was present in ten patients. The configuration of the cranial vault in some of these ten patients with dolichocephaly varied somewhat from that seen in nonsyndromic sagittal synostosis. In one patient, a Chiari I malformation was demonstrated by MRI. In another patient with increased intracranial pressure the sagittal suture closure was associated with lambdoidal synostosis. Dolichocephaly was not present in three patients, suggesting that the synostosis started later than in the other patients, probably in the second year of life, a period of slower brain growth than in the first year. The two patients in this group of three showed thickening and sclerosis of the cranial vault of uncertain etiology. There is an increased risk of sagittal synostosis in hypophosphatemic rickets and related diseases in children. The appearance of the cranial vault in this type of synostosis can vary from that seen in nonsyndromic synostosis. In this setting, careful clinical and imaging follow-up is warranted. (orig.)

  11. Sagittal synostosis in X-linked hypophosphatemic rickets and related diseases

    International Nuclear Information System (INIS)

    Currarino, Guido

    2007-01-01

    The recent observations of two new cases of X-linked hypophosphatemic rickets associated with premature closure of the sagittal suture prompted a review of similar cases seen in this institution. To review the clinical records and skull radiographs of 28 children with hypophosphatemic rickets in order to investigate the frequency and type of craniosynostosis and other cranial vault changes seen in these conditions and to review the literature for relevant findings. Clinical and imaging records were reviewed on 28 patients with hypophosphatemic rickets, all younger than 18 years. Most patients had X-linked hypophosphatemic rickets and a few had autosomal-dominant hypophosphatemic rickets or were non-familial cases. Of the 28 patients, 13 had sagittal synostosis. Dolichocephaly was present in ten patients. The configuration of the cranial vault in some of these ten patients with dolichocephaly varied somewhat from that seen in nonsyndromic sagittal synostosis. In one patient, a Chiari I malformation was demonstrated by MRI. In another patient with increased intracranial pressure the sagittal suture closure was associated with lambdoidal synostosis. Dolichocephaly was not present in three patients, suggesting that the synostosis started later than in the other patients, probably in the second year of life, a period of slower brain growth than in the first year. The two patients in this group of three showed thickening and sclerosis of the cranial vault of uncertain etiology. There is an increased risk of sagittal synostosis in hypophosphatemic rickets and related diseases in children. The appearance of the cranial vault in this type of synostosis can vary from that seen in nonsyndromic synostosis. In this setting, careful clinical and imaging follow-up is warranted. (orig.)

  12. Effect of binder concentration and blade gap on Yttria stabilized Zirconia tapes obtained by tape casting

    Energy Technology Data Exchange (ETDEWEB)

    Mena Garcia, J.; Reyes Rojas, A.; Rodriguez Gonzalez, C.A.; Hernandez Paz, J.; Garcia Casillas, P.E.; Enriquez Carrejo, J.L.; Camacho Montes, H.

    2016-07-01

    The tape casting method has kept its interest over the years due to the wide spectrum of its applications and its economic viability in comparison to other techniques focused on micrometric thin films. Two key parameters for tape casting are the binder relative amount and the Dr. Blade gap. The binder relative amount has a strong influence on the rheological properties for the ceramic YSZ slurry (ethanol, butanone, TEA, PVB, PEG, DEP). The coefficient K and the exponent m of the Cross model are reported to be inside the ranges 152.25-231.12 and 0.00987-0.26646 for PVB binder weight percentage concentrations between 6% and 12%. It is possible to describe the ceramic tape thickness dependence by means of a linear relation depending on the Dr. Blade gap whose linear coefficients (slope) are equal to 0.0350 and 0.2171 for green and sintered tapes respectively, with the YSZ slurry of the present work. (Author)

  13. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  14. Increasing the efficiency of tape-based storage backends

    International Nuclear Information System (INIS)

    Bessone, Nicola; Cancio, German; Murray, Steve; Taurelli, Giulia

    2010-01-01

    HSM systems such as the CERN's Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for increasing the performance of repacking data from old to newer generation tape media with substantially reduced hardware costs. In this paper, we will describe the improvements for migration policies and priorities, as well as the proposed tape format and the changes which will be applied to the architecture of the CASTOR mass storage system.

  15. Methods and systems for fabricating high quality superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  16. Increasing the efficiency of tape-based storage backends

    CERN Document Server

    Bessone, N; Murray, S; Taurelli, G; CERN. Geneva. IT Department

    2010-01-01

    HSM systems such as the CERN’s Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for incre...

  17. Role of perineal ultrasonography in postoperative evaluation of patients with stress incontinence

    International Nuclear Information System (INIS)

    Ko, Seog Wan; Jeong, Yong Yeon; Kang, Heoung Keun; Chung, Tae Woong; Seo, Jeong Jin; Park, Jin Gyoon; Kwon, Dong Deuk

    2001-01-01

    To evaluate the effectiveness of perineal ultrasonography in the evaluation of female stress incontinence after surgical management. Perineal ultrasonography was performed in 19 patients who were surgically treated for stress incontinence and this was performed in erect position. Nineteen patients were divided into two groups, group A for 11 patients with resolved incontinent after surgery and group B for 8 patients with persistent incontinence even after surgery. Using a sagittal scan of the anterior pelvis at the level of the symphysis pubis, the posterior urethrovesical angel (PUVA) and descent of the bladder neck were measured at rest and during stress (Valsalva maneuver), and these measured values obtained before and after surgery were compared between two groups, group A and B. Postoperative PUVA and descent of the bladder neck were decreased when compared with preoperative values measured at rest and during stress in both groups. There was a statistically significant difference in the postoperative PUVA between two groups (p< 0.05). The mean increment of PUVA during stress after surgery was 6.3 ± 3.8. deg in group A and 14.6 ± 6.4. deg in group B, respectively, showing statistically significant difference (p< 0.05). There was also a statistically difference in the mean descent of the bladder neck during stress after surgery between the two groups (p<0.05). The measurement and comparison of PUVA and descent of the bladder neck by perineal ultrasonography before and after surgery in patients with stress incontinence offered useful and objective information in evaluating the effectiveness of surgical management in females stress incontinence, the stress effectiveness in the stress incontinence.

  18. Synostosis Between Pubic Bones due to Neurogenic, Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Subramanian Vaidyanathan

    2006-01-01

    Full Text Available Neurogenic, heterotopic ossification is characterised by the formation of new, extraosseous (ectopic bone in soft tissue in patients with neurological disorders. A 33-year-old female, who was born with spina bifida, paraplegia, and diastasis of symphysis pubis, had indwelling urethral catheter drainage and was using oxybutynin bladder instillations. She was prescribed diuretic for swelling of feet, which aggravated bypassing of catheter. Hence, suprapubic cystostomy was performed. Despite anticholinergic therapy, there was chronic urine leak around the suprapubic catheter and per urethra. Therefore, the urethra was mobilised and closed. After closure of the urethra, there was no urine leak from the urethra, but urine leak persisted around the suprapubic catheter. Cystogram confirmed the presence of a Foley balloon inside the bladder; there was no urinary fistula. The Foley balloon ruptured frequently, leading to extrusion of the Foley catheter. X-ray of abdomen showed heterotopic bone formation bridging the gap across diastasis of symphysis pubis. CT of pelvis revealed heterotopic bone lying in close proximity to the balloon of the Foley catheter; the sharp edge of heterotopic bone probably acted like a saw and led to frequent rupture of the balloon of the Foley catheter. Unique features of this case are: (1 temporal relationship of heterotopic bone formation to suprapubic cystostomy and chronic urine leak; (2 occurrence of heterotopic ossification in pubic region; (3 complications of heterotopic bone formation viz. frequent rupture of the balloon of the Foley catheter by the irregular margin of heterotopic bone and difficulty in insertion of suprapubic catheter because the heterotopic bone encroached on the suprapubic track; (4 synostosis between pubic bones as a result of heterotopic ossification..Common aetiological factors for neurogenic, heterotopic ossification, such as forceful manipulation, trauma, or spasticity, were absent in this

  19. Sagittal synostosis: I. Preoperative morphology of the skull

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the preoperative morphology of the skull in sagittal synostosis in an objective and quantified way. The shapes of the skulls of 105 patients with isolated premature synostosis of the sagittal suture ( SS group) were studied and compared with those......, skull base, and orbit ( 42 in the lateral and 46 in the frontal projections), the production of plots of mean shape for each group, and the intergroup comparison of a series of 81 variables ( linear distance between selected landmarks, and angles defined by groups of three landmarks). Data from...... skull width. Comparison of the mean values of an SS subgroup to age-matched normative data showed a longer (p differ significantly...

  20. Training intensity and sagittal curvature of the spine in male and female artistic gymnasts.

    Science.gov (United States)

    Sanz-Mengibar, Jose M; Sainz-de-Baranda, Pilar; Santonja-Medina, Fernando

    2018-04-01

    Specific adaptations of the spine in the sagittal plane have been described according to different sports disciplines. The goal of this study was to describe the integrative diagnosis of the sagittal morphotype of the spine in male and female artistic gymnasts. Forty-eight gymnasts were measured with an inclinometer. Thoracic and lumbar curves were quantified in standing position, in Sit and Reach and Slump Sitting in order to assess the sagittal spine posture and analyze if adaptations were related to training intensity. Correlation values of the sagittal plane spine measurements showed significantly increased thoracic kyphosis in men (-0.445, Partistic gymnastics; however, this sport seems to cause specific adaptations in postural hypolordosis, functional thoracic kyphosis and lumbar kyphotic attitude during sitting and trunk flexion. The implications of the functional adaptations observed in our results may require a preventive intervention in male and female artistic gymnasts can be assessed with the integrative diagnosis of the sagittal morphotype of the spine.

  1. Sagittal imbalance in patients with lumbar spinal stenosis and outcomes after simple decompression surgery.

    Science.gov (United States)

    Shin, E Kyung; Kim, Chi Heon; Chung, Chun Kee; Choi, Yunhee; Yim, Dahae; Jung, Whei; Park, Sung Bae; Moon, Jung Hyeon; Heo, Won; Kim, Sung-Mi

    2017-02-01

    Lumbar spinal stenosis (LSS) is the most common lumbar degenerative disease, and sagittal imbalance is uncommon. Forward-bending posture, which is primarily caused by buckling of the ligamentum flavum, may be improved via simple decompression surgery. The objectives of this study were to identify the risk factors for sagittal imbalance and to describe the outcomes of simple decompression surgery. This is a retrospective nested case-control study PATIENT SAMPLE: This was a retrospective study that included 83 consecutive patients (M:F=46:37; mean age, 68.5±7.7 years) who underwent decompression surgery and a minimum of 12 months of follow-up. The primary end point was normalization of sagittal imbalance after decompression surgery. Sagittal imbalance was defined as a C7 sagittal vertical axis (SVA) ≥40 mm on a 36-inch-long lateral whole spine radiograph. Logistic regression analysis was used to identify the risk factors for sagittal imbalance. Bilateral decompression was performed via a unilateral approach with a tubular retractor. The SVA was measured on serial radiographs performed 1, 3, 6, and 12 months postoperatively. The prognostic factors for sagittal balance recovery were determined based on various clinical and radiological parameters. Sagittal imbalance was observed in 54% (45/83) of patients, and its risk factors were old age and a large mismatch between pelvic incidence and lumbar lordosis. The 1-year normalization rate was 73% after decompression surgery, and the median time to normalization was 1 to 3 months. Patients who did not experience SVA normalization exhibited low thoracic kyphosis (hazard ratio [HR], 1.04; 95% confidence interval [CI], 1.02-1.10) (pimbalance was observed in more than 50% of LSS patients, but this imbalance was correctable via simple decompression surgery in 70% of patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. DICOM implementation on online tape library storage system

    Science.gov (United States)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  3. Melt processing of Yb-123 tapes

    International Nuclear Information System (INIS)

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-01-01

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J c increased with decrease in pO 2 . The highest I c obtained was 52 A at 4.2 K

  4. The Influence of Natural Head Position on the Cervical Sagittal Alignment

    Directory of Open Access Journals (Sweden)

    Kuan Wang

    2017-01-01

    Full Text Available Introduction. This study investigated the relationship between the parameters related to the natural head position and cervical segmental angles and alignment of patients with neck pain. Material and Methods. The lateral radiographs of the cervical spine were collected from 103 patients and were used to retrospectively analyze the correlation between the natural head position, cervical local sagittal angles, and alignment. Sagittal measurements were as follows: cervical curvature classification, slope of McGregor’s line (McGS, local sagittal angles (C0–C2 angle, C2–C5 angle, C5–C7 angle, and C2–C7 angle, T1 slope, center of gravity of the head to sagittal vertical axis (CG–C7 SVA, and local sagittal alignment (C0–C2 SVA and C2–C7 SVA. Results. McGS was significantly correlated to C0–C2 angle (r=0.57, C0–C2 SVA (r=−0.53, C2–C7 SVA (r=−0.28, and CG–C7 SVA (r=−0.47. CG–C7 SVA was also significantly correlated to curvature type (r=0.27, C5–C7 angle (r=−0.37, and C2–C7 angle (r=−0.39. Conclusions. A backward shift with an extended head position may accompany a relatively normal curvature of the cervical spine. The effect of posture control in relieving abnormal mechanical state of the cervical spine needs to be further confirmed by biomechanical analysis.

  5. Transmission electron microscopy investigation of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Andersen, L.G.; Bals, S.; Tendeloo, G. Van

    2001-01-01

    during the tape processing, (3) a study of the grain boundaries on an atomic scale, including intergrowth investigations. Tapes with different process parameters have been compared with respect to the microstructure. A fully processed tape has on the average 50% thicker Bi-2223 grains than a tape after......The microstructure of (Bi,Pb)(2)Sr2Ca2CuOx (Bi-2223) tapes has been investigated by means of transmission electron microscopy (TEM) and high-resolution TEM. The emphasis has been placed on: (1) an examination of the grain morphology and size, (2) grain and colony boundary angles, which are formed...

  6. Perceived Organizational Red Tape and Organizational Performance in Public Services

    DEFF Research Database (Denmark)

    Jacobsen, Christian Bøtcher; Jakobsen, Mads Leth

    2018-01-01

    The claim that perceived organizational red tape hampers public services has become a central theme in public administration research. Surprisingly, however, few scholars have empirically examined the impact of perceived red tape on organizational performance. This study empirically analyzes how...... perceived organizational red tape among managers and frontline staff relates to objectively measured performance. The data consists of survey responses from teachers and principals at Danish upper secondary schools combined with grade-level administrative performance data. Based on theories of red tape...... and motivation crowding, we hypothesize that perceived organizational red tape reduces performance within such organizations. The empirical result is a small, negative relationship between staff perception of red tape and performance, and no relationship between manager-perceived red tape and performance....

  7. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    Science.gov (United States)

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  8. Melt formed superconducting joint between superconducting tapes

    International Nuclear Information System (INIS)

    Benz, M.G.; Knudsen, B.A.; Rumaner, L.E.; Zaabala, R.J.

    1992-01-01

    This patent describes a superconducting joint between contiguous superconducting tapes having an inner laminate comprised of a parent-metal layer selected from the group niobium, tantalum, technetium, and vanadium, a superconductive intermetallic compound layer on the parent-metal layer, a reactive-metal layer that is capable of combining with the parent-metal and forming the superconductive intermetallic compound, the joint comprising: a continuous precipitate of the superconductive intermetallic compound fused to the tapes forming a continuous superconducting path between the tapes

  9. Sagittal alignment after single cervical disc arthroplasty.

    Science.gov (United States)

    Guérin, Patrick; Obeid, Ibrahim; Gille, Olivier; Bourghli, Anouar; Luc, Stéphane; Pointillart, Vincent; Vital, Jean-Marc

    2012-02-01

    Prospective study. To analyze the sagittal balance after single-level cervical disc replacement (CDR) and range of motion (ROM). To define clinical and radiologic parameters those have a significant correlation with segmental and overall cervical curvature after CDR. Clinical outcomes and ROM after CDR with Mobi-C (LDR, Troyes, France) prosthesis have been documented in few studies. No earlier report of this prosthesis has studied correlations between static and dynamic parameters or those between static parameters and clinical outcomes. Forty patients were evaluated. Clinical outcome was assessed using the Short Form-36 questionnaire, Neck Disability Index, and a Visual Analog Scale. Spineview software (Surgiview, Paris, France) was used to investigate sagittal balance parameters and ROM. The mean follow-up was 24.3 months (range: 12 to 36 mo). Clinical outcomes were satisfactory. There was a significant improvement of Short Form-36, Neck Disability Index, and Visual Analog Scale scores. Mean ROM was 8.3 degrees preoperatively and 11.0 degrees postoperatively (P=0.013). Mean preoperative C2C7 curvature was 12.8 and 16.0 degrees at last follow-up (P=0.001). Mean preoperative functional spinal unit (FSU) angle was 2.3 and 5.3 degrees postoperatively (P<0.0001). Mean postoperative shell angle was 5.5 degrees. There was a significant correlation between postoperative C2C7 alignment and preoperative C2C7 alignment, change of C2C7 alignment, preoperative and postoperative FSU angle, and prosthesis shell angle. There was also a significant correlation between postoperative FSU angle and preoperative C2C7 alignment, preoperative FSU angle, change of FSU angle, and prosthesis shell angle. Regression analysis showed that prosthesis shell angle and preoperative FSU angle contributed significantly to postoperative FSU angle. Moreover, preoperative C2C7 alignment, preoperative FSU angle, postoperative FSU angle, and prosthesis shell angle contributed significantly to

  10. Multiple Generations on Video Tape Recorders.

    Science.gov (United States)

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  11. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, K. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)], E-mail: Kazunari.Motohashi@jp.sony.com; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)

    2008-11-15

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M{sub r}t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape.

  12. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    International Nuclear Information System (INIS)

    Motohashi, K.; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S.

    2008-01-01

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M r t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape

  13. Strategic Considerations for Effective Sagittal Resection of the Mandible to Achieve a Slim and Attractive Jawline.

    Science.gov (United States)

    Park, Sanghoon; Lee, Tae Sung

    2018-01-01

    Sagittal resection of the mandible has been widely used to reduce the width of the lower face and is usually carried out in combination with a mandibular contouring procedure. However, the surgical outcomes of this procedure are unclear because sagittal resection is rarely performed as a single procedure. The authors clarify misunderstandings regarding this procedure and introduce an improved strategic approach for sagittal resection of the mandible. Under general anesthesia, mandible contouring was performed first with a curved osteotomy, followed by sagittal resection of the outer cortex of mandible. The amount and extent of each procedure was determined in accordance with preoperative analysis. From 2012 to 2014, a consecutive series of 212 patients who underwent mandible contouring surgery without concomitant chin surgery were included in the study. A total of 189 patients underwent both mandibular contouring surgery and sagittal resection, whereas 13 underwent only sagittal resection and 10 underwent only mandibular contouring surgery. All operations were carried out successfully without any severe complications, and most patients had satisfactory aesthetic outcomes. The authors found that the sagittal resection of the mandible should be performed in accordance with the shape of the mandible to effectively reduce facial width and achieve better aesthetic outcomes for both profile and frontal views. In an outcurved-type mandible, conventional mandibular contouring may be effective alone, whereas sagittal resection focusing on removing the mandible body region is essential for incurved-type mandibles. In straight line-type mandibles, both procedures are necessary. Therapeutic, IV.

  14. SAGITTAL DIAMETER OF FORAMEN MAGNUM IN NORMAL POPULATION: AN MRI STUDY

    OpenAIRE

    Lakshmi

    2015-01-01

    Lower position of cerebellar tonsils was frequently noticed in Western studies. In some of the studies, sagittal diameter of foramen magnum was found to be larger in cases of Chiari malformation. However, there are no Indian studies for comparison. Our study was proposed to determine the standard values for sagittal diameter of foramen magnum in various age groups and both sexes. This gives a guideline for further studies in pathological conditions like Craniovertebral Junctional ...

  15. Preparing superconducting nanopowder based YBCO/Ag tapes

    DEFF Research Database (Denmark)

    Paturi, P.; Raittila, J.; Grivel, J.C.

    2002-01-01

    YBCO nanopowder consisting of 1-3 nm thick and 40 nm wide particles has been used to make silver clad superconducting tapes. After annealing in nitrogen at 945 degreesC for 10 h a critical current of 5.02 A (3300 A/cm(2)) was attained, Annealing in mixed atmosphere of oxygen and nitrogen was also...... carried out and this procedure produced tapes with a critical current of 2.83 A (2200 A/cm(2)). These tapes show very good characteristics in magnetic fields. (C) 2002 Elsevier Science B.V. All rights reserved....

  16. 'Lumbar Degenerative Kyphosis' Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception.

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-03-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal deformity. Unlike what its name suggests, LDK does not only include sagittal balance disorder of the lumbar spine and kyphosis, but also sagittal balance disorder of the whole spine and little lordosis of the lumbar spine. Moreover, this disease is closely related to the occupation of female farmers and an outdated Asian life style. These reasons necessitate a change in the nomenclature of this disorder to prevent misunderstanding. We suggest the name "primary degenerative sagittal imbalance" (PDSI), which encompasses degenerative sagittal misalignments of unknown origin in the whole spine in older-age patients, and is associated with back muscle wasting. LDK may be regarded as a subgroup of PDSI related to an occupation in agriculture. Conservative treatments such as exercise and physiotherapy are recommended as first-line treatments for patients with PDSI, and surgical treatment is considered only if conservative treatments failed. The measurement of spinopelvic parameters for sagittal balance is important prior to deformity corrective surgery. LDK can be considered a subtype of PDSI that is more likely to occur in female farmers, and hence the use of LDK as a global term for all degenerative sagittal imbalance disorders is better avoided. To avoid confusion, we recommend PDSI as a newer, more accurate diagnostic term instead of LDK.

  17. Fabrication of Polyimide-Matrix/Carbon and Boron-Fiber Tape

    Science.gov (United States)

    Belvin, Harry L.; Cano, Roberto J.; Treasure, Monte; Shahood, Thomas W.

    2007-01-01

    The term HYCARB denotes a hybrid composite of polyimide matrices reinforced with carbon and boron fibers. HYCARB and an improved process for fabricating dry HYCARB tapes have been invented in a continuing effort to develop lightweight, strong composite materials for aerospace vehicles. Like other composite tapes in this line of development, HYCARB tapes are intended to be used to build up laminated structures having possibly complex shapes by means of automated tow placement (ATP) - a process in which a computer-controlled multiaxis machine lays down prepreg tape or tows. The special significance of the present process for making dry HYCARB for ATP is that it contributes to the reduction of the overall cost of manufacturing boron-reinforced composite-material structures while making it possible to realize increased compression strengths. The present process for making HYCARB tapes incorporates a "wet to dry" process developed previously at Langley Research Center. In the "wet to dry" process, a flattened bundle of carbon fiber tows, pulled along a continuous production line between pairs of rollers, is impregnated with a solution of a poly(amide acid) in N-methyl-2-pyrrolidinone (NMP), then most of the NMP is removed by evaporation in hot air. In the present case, the polyamide acid is, more specifically, that of LaRC. IAX (or equivalent) thermoplastic polyimide, and the fibers are, more specifically, Manganite IM7 (or equivalent) polyacrylonitrile- based carbon filaments that have a diameter of 5.2 m and are supplied in 12,000-filament tows. The present process stands in contrast to a prior process in which HYCARB tape was made by pressing boron fibers into the face of a wet carbon-fiber/ poly(amide acid) prepreg tape . that is, a prepreg tape from which the NMP solvent had not been removed. In the present process, one or more layer(s) of side-by-side boron fibers are pressed between dry prepreg tapes that have been prepared by the aforementioned gwet to dry h

  18. Measuring Fractional Anisotropy of the Corpus Callosum Using Diffusion Tensor Imaging: Mid-Sagittal versus Axial Imaging Planes

    International Nuclear Information System (INIS)

    Kim, Eung Yeop; Park, Hae Jeong; Kim, Dong Hyun; Lee, Seung Koo; Kim, Jin Na

    2008-01-01

    Many diffusion tensor imaging (DTI) studies of the corpus callosum (CC) have been performed with a relatively thick slice thickness in the axial plane, which may result in underestimating the fractional anisotropy (FA) of the CC due to a partial volume effect. We hypothesized that the FA of the CC can be more accurately measured by using mid-sagittal DTI. We compared the FA values of the CC between the axial and mid-sagittal DTI. Fourteen healthy volunteers underwent MRI at 3.0 T. DTI was performed in both the mid-sagittal and axial planes. One 5-mm mid-sagittal image and twenty-five 2-mm axial images were obtained for the CC. The five regions of interest (ROIs) that included the prefrontal (I), premotor and supplementary motor (II), motor (III), sensory (IV) and parietal, temporal and occipital regions (V) were drawn along the border of the CC on each sagittal FA map. The FA values obtained from each region were compared between the two sagittal maps. The FA values of all the regions, except for region V, were significantly increased on the mid-sagittal imaging. The FA values in region IV were significantly underestimated on the mid-sagittal image from the axial imaging, compared with those in the regions I and V (p = 0.037 and p = 0.001, respectively). The FA values of the CC were significantly higher on the midsagittal DTI than those on the axial DTI in regions I-IV, and particularly in the region IV. Mid-sagittal DTI may provide more accurate FA values of the CC than can the axial DTI, and mid-sagittal DTI may be more desirable for studies that compare between patients and healthy subjects

  19. Experimental Tape Casting of Adjacently Graded Materials for Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina

    encompass modification of the entire tape caster into a multi chamber unit, establishment of the optimal operating parameters such as casting gap, speed, and slurry level in the tape caster reservoir, and elucidation of the impact of chamber partition design on the quality of the final tape. The second...... of the side-by-side tape casting technique: recognising critical parameters which affect the quality of a graded tape, shape and position of the interface area. Studied parameters can be divided into two categories: operational parameters and slurry formulation optimisation. The operational parameters...

  20. Sagittal Alignment As a Predictor of Clinical Adjacent Segment Pathology requiring Surgery after Anterior Cervical Arthrodesis

    Science.gov (United States)

    Park, Moon Soo; Kelly, Michael P.; Lee, Dong-Ho; Min, Woo-Kie; Rahman, Ra’Kerry K.; Riew, K. Daniel

    2014-01-01

    BACKGROUND CONTEXT Postoperative malalignment of the cervical spine may alter cervical spine mechanics, and put patients at risk for clinical adjacent segment pathology requiring surgery. PURPOSE To investigate whether a relationship exists between cervical spine sagittal alignment and clinical adjacent segment pathology requiring surgery (CASP-S) following anterior cervical fusion (ACF). STUDY DESIGN Retrospective matched study. PATIENT SAMPLE One hundred twenty two patients undergoing ACF from 1996 to 2008 were identified, with a minimum of 2 year follow-up. OUTCOME MEASURES Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior endplate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. METHODS One hundred twenty two patients undergoing ACF from 1996 to 2008 were identified, with a minimum of 1 year follow-up. Patients were divided into groups according to the development of CASP requiring surgery (Control / CASP-S) and by number/location of levels fused. Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior endplate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. Appropriate statistical tests were performed to calculate relationships between the variables and the development of CASP-S. No funds were received in support of this work. No benefits in any form have been or will be received from a commercial party related

  1. Comparison of accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions: An exvivo study

    Directory of Open Access Journals (Sweden)

    Asieh Zamani Naser

    2010-01-01

    Full Text Available Background: Radiographic examination of TMJ is indicated when there are clinical signs of pathological conditions, mainly bone changes that may influence the diagnosis and treatment planning. The purpose of this study was to evaluate and to compare the validity and diagnostic accuracy of uncorrected and corrected sagittal tomographic images in the detection of simulated mandibular condyle erosions. Methods : Simulated lesions were created in 10 dry mandibles using a dental round bur. Using uncorrected and corrected sagittal tomography techniques, mandibular condyles were imaged by a Cranex Tome X-ray unit before and after creating the lesions. The uncorrected and corrected tomography images were examined by two independent observers for absence or presence of a lesion. The accuracy for detecting mandibular condyle lesions was expressed as sensitivity, specificity, and validity values. Differences between the two radiographic modalities were tested by Wilcoxon for paired data tests. Inter-observer agreement was determined by Cohen′s Kappa. Results: The sensitivity, specificity and validity were 45%, 85% and 30% in uncorrected sagittal tomographic images, respectively, and 70%, 92.5% and 60% in corrected sagittal tomographic images, respectively. There was a significant statistical difference between the accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions (P = 0.016. The inter-observer agreement was slight for uncorrected sagittal tomography and moderate for corrected sagittal tomography. Conclusion: The accuracy of corrected sagittal tomography is significantly higher than that of uncorrected sagittal tomography. Therefore, corrected sagittal tomography seems to be a better modality in detection of mandibular condyle erosions.

  2. Tamper tape seals

    International Nuclear Information System (INIS)

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R ampersand D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique open-quotes fingerprintclose quotes characteristics that can be accessed as desired

  3. Direct CT scanning of the lesser pelvis - frontal vs sagittal plane

    International Nuclear Information System (INIS)

    Khadzhigeorgiev, G.; Lichev, A.

    1994-01-01

    Whenever axial scanning alone is used, the anatomical patterns of the true pelvis and the organs contained in it, particularly in women, give rise to diagnostic difficulties during CT assessment of neoplasms originating from these organs. The high demands on precision characterization of the pathological changes in the pelvis minor organs necessitate the obtaining of reliable density and size measurement data, not merely from the axial plane, but from the frontal and sagittal ones as well. The deficient information afforded by secondary reconstruction of the pelvis mind images requires an mandatory evaluation of the potentialities of direct frontal and direct sagittal scanning of the pelvis minor using standard CT equipment. Information yielded by images from direct frontal and direct sagittal pelvis minor scanning as well as diagnostic problems where application of this type of scanning is indicated operational difficulties and their overcoming, are among the issues discussed. 8 figs., 7 refs

  4. A comparison of cephalometric analyses for assessing sagittal jaw relationship

    International Nuclear Information System (INIS)

    Erum, G.; Fida, M.

    2008-01-01

    To compare the seven methods of cephalometric analysis for assessing sagittal jaw relationship and to determine the level of agreement between them. Seven methods, describing anteroposterior jaw relationships (A-B plane, ANB, Wits, AXB, AF-BF, FABA and Beta angle) were measured on the lateral cephalographs of 85 patients. Correlation analysis, using Cramer's V-test, was performed to determine the possible agreement between the pair of analyses. The mean age of the sample, comprising 35 males and 50 females was 15 years and 3 months. Statistically significant relationships were found among seven sagittal parameters with p-value <0.001. Very strong correlation was found between AXB and AF-BF distance (r=0.924); and weak correlation between ANB and Beta angle (r=0.377). Wits appraisal showed the greatest coefficient of variability. Despite varying strengths of association, statistically significant correlations were found among seven methods for assessing sagittal jaw relationship. FABA and A-B plane may be used to predict the skeletal class in addition to the established ANB angle. (author)

  5. PARAMETERS FOR THE EVALUATION OF CERVICAL SAGITTAL BALANCE IN IDIOPATHIC SCOLIOSIS

    Directory of Open Access Journals (Sweden)

    MAURICIO COELHO LIMA

    Full Text Available ABSTRACT Objective: There are no values defined as standard in the literature for the parameters of assessment of cervical sagittal balance in patients with idiopathic scoliosis. This study describes the sagittal cervical parameters in patients with idiopathic scoliosis. Methods: Study carried out in a tertiary public hospital in patients with adolescent idiopathic scoliosis, through the evaluation of panoramic radiographs in lateral view. The Cobb method was used to evaluate cervical lordosis from C2 to C7, distance from the center of gravity (COG of the skull to C7, measurement of T1 slope, thoracic inlet angle (TIA, neck tilt, and plumb line from C7 to S1 (SVA C7-S1. A statistical analysis was performed, to demonstrate the relationship between the alignment of the thoracic spine in the sagittal plane and the cervical sagittal balance of patients with scoliosis. Results: Thirty-four patients were female (69.4% and 15 male (30.6%. The mean values for COG-C7 were 0.71 mm (median 0.8 mm/standard deviation [SD]= 0.51 mm. For Cobb C2-C7, the mean was -11.7° (median -10°/SD= 20.4°. The mean slope of T1 was 23.5° (median 25°/SD= 9.5°. The mean cervical version was 58.8° (median 60°/DP= 15.4°. The mean TIA was 81.8° (median 85°/SD= 16.7°. The mean plumb line C7-S1 was -0.28 (-0.3/SD= 1.0. Conclusion: The analysis of the results showed that the mean values for the cervical lordosis are lower than the values described as normal in the literature, suggesting a loss of sagittal cervical balance in these patients.

  6. Kinesio Taping Fundamentals for the Equine Athlete.

    Science.gov (United States)

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Sagittal plane analysis of the spine and pelvis in degenerative lumbar scoliosis.

    Science.gov (United States)

    Han, Fei; Weishi, Li; Zhuoran, Sun; Qingwei, Ma; Zhongqiang, Chen

    2017-01-01

    Previous studies have reported the normative values of pelvic sagittal parameters, but no study has analyzed the sagittal spino-pelvic alignment in degenerative lumbar scoliosis (DLS) and its role in the pathogenesis. Retrospective analysis was applied to 104 patients with DLS, together with 100 cases of asymptomatic young adults as a control group and another control group consisting of 145 cases with cervical spondylosis. The coronal and sagittal parameters were measured on the anteroposterior and lateral radiograph of the whole spine in the DLS group as well as in the two control groups. Statistical analysis showed that the DLS group had a higher pelvic incidence (PI) value (50.5° ± 10.2°), than the normal control group (with PI 47.2° ± 8.8°) and the cervical spondylosis group (46.9° ± 9.1°). In DLS group, there were 38 cases (36.5%) complicated with degenerative lumbar spondylolisthesis, who had higher PI values than patients without it. Besides, the lumbar lordosis (LL) and sacral slope (SS) of DLS group were lower; the scoliosis Cobb's angle was correlated with pelvic tilt (PT); thoracic kyphosis was correlated with LL, SS, and PT; and LL was correlated with other sagittal parameters. Patients with DLS may have a higher PI, which may impact the pathogenesis of DLS. A high PI value is probably associated with the high prevalence of degenerative lumbar spondylolisthesis among DLS patients. In DLS patients, the lumbar spine maintains the ability of regulating the sagittal balance, and the regulation depends more on thoracic curve.

  8. Three-dimensional modelling of metal evaporated tape

    International Nuclear Information System (INIS)

    Kay, G.E.

    1999-06-01

    As developments in magnetic recording increase, the demands for high density recording media continue to rise. One particular medium developed towards meeting these needs is the commercially successful metal evaporated (ME) tape. To provide a deeper understanding of the magnetic processes occurring in recording media, theoretical studies are carried out to complement experimental observations. Therefore, this thesis is concerned with developing a micromagnetic model to simulate the magnetic behaviour of ME tape. ME tape consists of bundles of granular columns which are tilted towards the film normal. The morphology of the film influences the magnetic behaviour and a 3D model is developed in this thesis to represent the columnar structure and the granular nature of ME tape. A Monte Carlo algorithm, consisting of a 'move and grow' procedure, is developed to generate an irregular system of spherical grains whose radii were generated from a log-normal distribution. This structure provides the foundation for modelling columns of ME tape. Initially an isolated column of ME tape was investigated. Grains were considered to be single domain and the dynamic process of the magnetic moments was explored by the Landau-Lifschitz equation. The model demonstrated that as the strength of the exchange coupling parameter increased, then moments which were strongly coupled resisted large negative fields and square hysteresis loops with a high coercivity were produced. Reversal of the moments was observed to be initiated at the ends of a column and then propagated throughout the column. This was attributed to large demagnetising fields and was particularly evident in the model with aligned easy axes. If the easy axes were randomly orientated then more disorder was present in the model and moments rotated incoherently. This produced hysteresis loops that were less square than those of the aligned model. The results also showed how the microstructure influenced the reversal processes

  9. Forensic utility of the carbon isotope ratio of PVC tape backings

    Science.gov (United States)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  10. Kejadian mikropenis pada anak obes

    Directory of Open Access Journals (Sweden)

    Siswanto Basuki

    2009-07-01

    Full Text Available Background : Obese children are more likely to have less testosterone, which may lead to disorder of penile development. Objectives : To assess the association between obesity in children and the occurrence of micropenis.  Methods : TA cross sectional study was carried out in 36 obese and 28 non- obese pubertal male children (10-13 years old and 49 obese and 36 non-obese prepubertal male children (4-7 years old. Obesity was defined as body mass index (BMI equivalent to or above the 95th percentile of the CDC 2000 growth reference standard. Length of the penis was measured perpendicular to the surface of the os symphysis pubis to the tip of the glans penis. Skinfold thickness was measured on the area of mons pubis using a caliper. Volume of the testis was measured using an orchidometer.  Results : The mean (SD of penis length in 36 pubertal obese and 28 non-obese children were 5.56 (1.14 cm and 6.05 (1.37 cm, respectively; whereas the mean (SD of penis length in 49 pre-pubertal obese and 39 non-obese children were 5.09 (0.76 cm and 5.36 (0.56 cm, respectively. There was significant difference in the mean (95% CI length of penis in pubertal obese and non-obese children (p = 0.04. Fisher's exact test showed that the occurrence of micropenis was not associated with obesity, age, fat thickness on mons pubis, and volume of the testicles. Conclusion : There was no significant difference in the occurrence of micropenis, but there was significant difference in the mean length of penis in obese children and children with normal age-related body mass index.

  11. Sports hernia or groin disruption injury? Chronic athletic groin pain: a retrospective study of 100 patients with long-term follow-up.

    Science.gov (United States)

    Garvey, J F W; Hazard, H

    2014-01-01

    Chronic groin pain (athletic pubalgia) is a common problem in sports such as football, hockey, cricket, baseball and athletics. Multiple co-existing pathologies are often present which commonly include posterior inguinal canal wall deficiency, conjoint tendinopathy, adductor tendinopathy, osteitis pubis and peripheral nerve entrapment. The mechanism of injury remains unclear but sports that involve either pivoting on a single leg (e.g. kicking) or a sudden change in direction at speed are most often associated with athletic pubalgia. These manoeuvres place large forces across the bony pelvis and its soft tissue supports, accounting for the usual clinical presentation of multiple symptomatic abnormalities forming one pattern of injury. The diagnoses encountered in this series of 100 patients included rectus abdominis muscle atrophy/asymmetry (22), conjoint tendinopathy (16), sports (occult, incipient) hernia (16), groin disruption injury (16), classical hernia (11) traumatic osteitis pubis (5), and avulsion fracture of the pubic bone (4). Surgical management was generally undertaken only after failed conservative therapy of 3-6 months, but some professionals who have physiotherapy during the football season went directly to surgery at the end of the football season. A variety of operations were performed including groin reconstruction (15), open hernia repair with or without mesh (11), sports hernia repair (Gilmore) (7) laparoscopic repair (3), conjoint tendon repair (3) and adductor tenotomy (3). Sixty-six patients were available for follow at an average of 13 years after initial consultation and the combined success rate for both conservative treatment and surgery was 94%. The authors believe that athletic pubalgia or sports hernia should be considered as a 'groin disruption injury', the result of functional instability of the pelvis. The surgical approach is aimed at strengthening the anterior pelvic soft tissues that support and stabilise the symphysis pubis.

  12. Influence of implant rod curvature on sagittal correction of scoliosis deformity

    DEFF Research Database (Denmark)

    Salmingo, Remel A.; Tadano, Shigeru; Abe, Yuichiro

    2014-01-01

    of the implant rod’s angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. STUDY DESIGN: A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. PATIENT SAMPLE: Twenty adolescent idiopathic......BACKGROUND CONTEXT: Deformation of in vivo–implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. PURPOSE: To analyze the changes...... scoliosis patients underwent surgery. Average age at the time of operation was 14 years. OUTCOME MEASURES: The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. METHODS: Two implant rods were attached to the concave and convex side...

  13. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    Science.gov (United States)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  14. Effects of ultrasound therapy with taping PNF training and PNF training with taping in treatment and rehabilitation of sports injuries of high ankle sprain

    Directory of Open Access Journals (Sweden)

    D L Charly Daniel

    2017-01-01

    Conclusions: It was concluded that combining ultrasound with taping and PNF training with taping were found to be more beneficial in the treatment and rehabilitation of high ankle sprain injury. The combined effect of UT, PNF training, and taping may be explored by future researchers.

  15. AC power losses in Bi-2223/Ag HTS tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Reilly, D.; Mueller, K.-H.; Herrmann, J.

    1998-01-01

    Full text: We report measurements at 77 K of the transport ac losses of Bi-2223/Ag composite tapes. The investigated tapes vary from single filament to multifilament construction and include both conventional tapes and other conductor shapes with twisted filaments. The self-field ac losses were determined at 77 K and 60 Hz as a function of ac current amplitude (0 - 100 A). We observe different behaviour among tapes depending on their quality and strain history. For 'good' virgin tapes the experimental data are well described by the Norris equations for the dependence of power loss P on the amplitude I m of the transport current. The data of good monofilament tapes are fitted to the Norris equation P ∼ I m n for an elliptical cross section (ie. n = 3) and the data of good multifilament tapes are fitted to the Norris equation for a rectangular strip (ie. n = 4). Many specimens, however, show a range of behaviour with lower values of n. Based on our work on the effect of strain on the dc transport properties of tapes, we carried out detailed investigations of the effect of controlled applied bend strain on the ac loss. Our results show that irreversible damage to superconducting filaments (ie. cracks) cause the ac loss to rise and n to decrease with increasing strain. In addition, applied strains much greater than the irreversible strain limit cause the ac loss to increase by several orders of magnitude and become ohmic in character with n = 2. Theoretical work is in progress to model the observed behaviour

  16. The longitudinal sagittal growth changes of maxilla and mandible according to quantitative cervical vertebral maturation.

    Science.gov (United States)

    Chen, Lili; Lin, Jiuxiang; Xu, Tianmin; Long, Xiaosi

    2009-04-01

    To investigate the longitudinal sagittal growth changes of maxilla and mandible according to the quantitative cervical vertebral maturation (QCVM) for adolescents with normal occlusion, mixed longitudinal data were used. The samples included 87 adolescents aged from 8 to 18 y old with normal occlusion (32 males, 55 females) selected from 901 candidates. Sequential lateral cephalograms and hand-wrist films were taken once a year, lasting for 6 y. The longitudinal sagittal growth changes of maxilla and mandible according to QCVM were measured. There were some significant differences between maxilla and mandible according to QCVM. The sagittal growth change of maxilla showed a trend towards high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. The sagittal growth change of mandible showed a trend towards accelerating velocity-->high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. With sagittal relationship, growth magnitude was almost the same between maxilla and mandible at QCVM stage I. At stage II the growth of mandible exceeded that of maxilla and growth in mandible continued at stages III and IV, while the maxilla ceased to grow. Growth magnitude was greater and the growth duration was longer with male mandible. It is concluded that the longitudinal sagittal growth changes of maxilla and mandible on the basis of QCVM is of value in the orthodontic practice.

  17. Data analysis of event tape and connection

    International Nuclear Information System (INIS)

    Gong Huili

    1995-01-01

    The data analysis on the VAX-11/780 computer is briefly described, the data is from the recorded event tape of JUHU data acquisition system on the PDP-11/44 computer. The connection of the recorded event tapes of the XSYS data acquisition system on VAX computer is also introduced

  18. Transobturator tapes are preferable over transvaginal tapes for the management of female stress urinary incontinence: Against

    Directory of Open Access Journals (Sweden)

    Arun Chawla

    2009-01-01

    Full Text Available Midurethral placement of tension-free vaginal tapes with a transvaginal route for stress urinary incontinence achieves higher and better long-term success rates than the transobturator route. Bladder perforations are reported more in transvaginal tape (TVT but incidences of vaginal erosions, extrusion, and groin pain are exceedingly more in TOT groups. There is no clear evidence that transobturator tape (TOT is associated with less post-operative voiding problems than TVT. Major complications such as bowel injuries and significant vascular injuries with TVT are rare. TVT has been found to be superior to TOT and preferable in technically demanding conditions such as prior anti-incontinence operation failures, obese women, and very elevated and scarred lateral cul-de sac. TVT is always preferred in severe grades of stress urinary incontinence and with patients of intrinsic sphincter deficiency (ISD with little or no urethral mobility.

  19. ‘Lumbar Degenerative Kyphosis’ Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-01-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal deformity. Unlike what its name suggests, LDK does not only include sagittal balance disorder of the lumbar spine and kyphosis, but also sagittal balance disorder of the whole spine and little lordosis of the lumbar spine. Moreover, this disease is closely related to the occupation of female farmers and an outdated Asian life style. These reasons necessitate a change in the nomenclature of this disorder to prevent misunderstanding. We suggest the name “primary degenerative sagittal imbalance” (PDSI), which encompasses degenerative sagittal misalignments of unknown origin in the whole spine in older-age patients, and is associated with back muscle wasting. LDK may be regarded as a subgroup of PDSI related to an occupation in agriculture. Conservative treatments such as exercise and physiotherapy are recommended as first-line treatments for patients with PDSI, and surgical treatment is considered only if conservative treatments failed. The measurement of spinopelvic parameters for sagittal balance is important prior to deformity corrective surgery. LDK can be considered a subtype of PDSI that is more likely to occur in female farmers, and hence the use of LDK as a global term for all degenerative sagittal imbalance disorders is better avoided. To avoid confusion, we recommend PDSI as a newer, more accurate diagnostic term instead of LDK. PMID:28264231

  20. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  1. Carbon Nanotube-Based Synthetic Gecko Tapes

    Science.gov (United States)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  2. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    International Nuclear Information System (INIS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-01-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour. (paper)

  3. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    Science.gov (United States)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  4. Radiographic Outcomes of Postoperative Taping Following Hallux Valgus Correction.

    Science.gov (United States)

    Ponzio, Danielle Y; Pedowitz, David I; Verma, Kushagra; Maltenfort, Mitchell G; Winters, Brian S; Raikin, Steven M

    2015-07-01

    Traditionally, hallux valgus operative correction has been accompanied by serial spica taping of the great toe during the postoperative period. We retrospectively reviewed 187 adult patients who underwent proximal first metatarsal osteotomy with a modified McBride procedure in 2008-2009 (n = 83) and 2011-2012 (n = 104). Postoperatively, to maintain the corrected position of the hallux, patients from 2008 through 2009 underwent weekly spica taping, while patients from 2011 through 2012 utilized a toe separator. The hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured using anteroposterior weight-bearing preoperative, 2-week postoperative non-weight-bearing, and 3-month weight-bearing final follow-up radiographs. A mixed-effects linear regression model identified differences between the treatment groups over time, and a t test compared actual radiographic differences at final follow-up. The mixed-effects model revealed no significant difference in the HVA over time when comparing patients taped to those not taped at the preoperative (33 ± 6 vs 33 ± 6), 2-week postoperative (10 ± 7 vs 9 ± 6), and 3-month follow-up (14 ± 6 vs 11 ± 7) visits (P = .08). At final follow-up, the HVA was lower for the group that was not taped, but the difference (2.5 degrees) was below the minimal clinically important difference (MCID) (P = .015, 95% CI 0.5-4.5). For IMA, there was improved maintenance of correction over time in the patients that were not taped compared to those taped at the preoperative (15 ± 3 vs 15 ± 3), 2-week postoperative (2 ± 2 vs 3 ± 3), and 3-month follow-up (5 ± 4 vs 7 ± 4) visits (P = .002). At final follow-up, the IMA was lower for the group that was not taped, but the difference (1.7 degrees) was below the MCID (P = .004, 95% CI 0.7-2.9). We report no radiographic benefit of postoperative taping after hallux valgus correction. The present study challenges the previous dogma of postoperative spica taping as the protocol is cost and

  5. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  6. Bending strain study of Bi-2223/Ag tapes using Hall sensor magnetometry

    International Nuclear Information System (INIS)

    Lahtinen, M.; Paasi, J.; Sarkaniemi, J.; Han, Z.; Freltoft, T.

    1996-01-01

    The influence of room temperature bending on critical current (I c ) of Bi-2223/Ag tapes is studied by Hall sensor magnetometry, four-point method and scanning electron microscopy. Hall sensor magnetometry allows one to assess tape homogeneity and the amount of mechanical damage caused by bending. The microstructure of the Bi-2223 ceramic is found to strongly affect the tape behavior under bending strain. In a tape with moderate I c = 6.1 A at 77 K and a porous ceramic core, crack propagation took place normal to the Ag-ceramic interface, whereas in tapes with dense core, I c above 10 A at 77 K, cracks propagated in the tape plane. In monofilamentary tapes core homogeneity correlated with good bending strain performance. In multifilamentary tapes crack propagation between filaments was prohibited by the Ag matrix, thus leading to enhanced strain tolerance. In the high I c tapes studied, bending to 25 mm radius resulted in 1%--2% I c degradation

  7. Simulation and analysis of tape spring for deployed space structures

    Science.gov (United States)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  8. Location of the ovaries in girls from newborn to 18 years of age: reconsidering ovarian shielding

    International Nuclear Information System (INIS)

    Bardo, Dianna M.E.; Schenk, Kellie; Black, Michelle; Zaritzky, Mario F.

    2009-01-01

    Guidelines for ovarian shielding are to place a lead shield in the midline of the abdomen at the level of the umbilicus. However, the ovaries are routinely seen at other locations on all types of imaging examinations. To determine the position of the ovaries in girls, newborn to 18 years of age, in order to assess efficacy of ovarian shield placement. We identified 336 girls who underwent lumbar spine and pelvic MRI. Images were reviewed noting the position of the ovaries relative to anatomic landmarks: symphysis pubis, iliac crest and anterior superior iliac spine (ASIS). In 174 girls a total of 307 ovaries were visualized. The girls were divided into three age groups and analyzed together. Right and left ovaries were analyzed together. The mean, 95% confidence interval (CI), standard deviations and range were calculated. The ovaries lay at or below the iliac crest (the level of the umbilicus), most often just medial to the ASIS and above the pubic symphysis in girls of all ages. Current methods of shielding only the midline of the pelvis for the purpose of reducing radiation dose to the ovaries during radiographic imaging are ineffective given that the ovaries are almost always positioned laterally in the pelvis. Therefore current shielding techniques should be changed; lead ovarian shields should be placed in a lateral position or even abandoned if relevant anatomy will be obscured. (orig.)

  9. The angle of inclination of the native ACL in the coronal and sagittal planes.

    Science.gov (United States)

    Reid, Jonathan C; Yonke, Bret; Tompkins, Marc

    2017-04-01

    The purpose of this cross-sectional study was to evaluate the angle of inclination of the native anterior cruciate ligament (ACL) in both the sagittal and coronal planes and to evaluate these findings based on sex, height, BMI, and skeletal maturity. Inclusion criteria for the study included patients undergoing routine magnetic resonance imaging (MRI) of the knee at a single outpatient orthopedic center who had an intact ACL on MRI. Measurements of the angle of inclination were made on MRIs in both the sagittal and coronal planes. Patients were compared based on sex, height, BMI, and skeletal maturity. One-hundred and eighty-eight patients were included (36 skeletally immature/152 skeletally mature; 98 male/90 female). The overall angle of inclination was 74.3° ± 4.8° in the coronal plane and 46.9° ± 4.9° in the sagittal plane. Skeletally immature patients (coronal: 71.8° ± 6.1°; sagittal: 44.7° ± 5.5°) were significantly different in both coronal and sagittal planes (P = 0.04 and 0.01, respectively) from skeletally mature patients (coronal: 75.3° ± 4.7°; sagittal: 47.4° ± 4.7°). There were no differences based on sex, height, or BMI. There are differences between the angle of inclination findings in this study and other studies, which could be due to MRI and measurement techniques. Clinically, skeletal maturity may be important to account for when using the ACL angle of inclination to evaluate anatomic ACL reconstruction. Prognostic retrospective study, Level of evidence III.

  10. Buffer layers grown by replicating the texture of an original template tape

    International Nuclear Information System (INIS)

    Lim, Sunme; Yoo, Jaeun; Park, Chan; Youm, Dojun

    2007-01-01

    We propose a fabrication method of the buffer layers, whose biaxial textures are replicated from an original template tape. The purpose of this method is economical texturing process for coated conductors. At first we prepared a biaxially textured metal tape (TM-tape). Then a sacrifice layer (SA), a buffer layer (BU) and a thick metallic layer (SM) were sequentially deposited on the TM-tape. SA-layer and BU-layer were deposited epitaxially to copy the texture of the TM-tape. SA-layer was dissoluble in water. SM-layer with the textured BU-layer was separated and could be used for a supporting tape for the further growth of a superconducting layer. In this way, it is possible to reuse the original textured TM-tape many times. In this paper, we report the results of our experiments, in which we used a biaxially Ni tape, BaO film, STO film, and a thick Ag film for TM-tape, SA-layer, BU-layer, and SM-layer, respectively. The Ag/STO layers were successfully separated form the Ni tape by dissolving the BaO layer in water. The texture quality of the STO layer was well secured after the separation

  11. Overcurrent experiments on HTS tape and cable conductor

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Jensen, Kim Høj; Træholt, Chresten

    2001-01-01

    their critical current. In this light, it is important to investigate the response of HTS tapes and cable conductors to overcurrents several times the critical current. A number of experiments have been performed on HTS tapes and cable conductors, with currents up to 20 times the critical current. During...... overcurrent experiments, the voltage, and the temperature were measured as functions of time in order to investigate the dynamic behavior of the HTS tape and cable conductor. After each experiment, damage to the superconductors was assessed by measuring the critical current. Preliminary results show...... that within seconds an HTS tape (critical current=17 A) heats above room temperature with an overcurrent larger than 140 A. Similar overcurrent experiments showed that a HTS cable conductor could sustain damage with overcurrents exceeding 10 times the critical current of the cable conductor....

  12. Superconducting flat tape cable magnet

    Science.gov (United States)

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  13. Investigation of reconstruction conditions in sagittal-plane multiplanar reconstruction of the temporal bone

    International Nuclear Information System (INIS)

    Suzuki, Miyako; Yoshikawa, Hiroshi; Hosokawa, Akira; Ichikawa, Ginichiro; Kobayashi, Kenichi; Ando, Ichiro

    2002-01-01

    In recent years, it has become possible to quickly obtain a large amount of 3D data with high continuity by helical CT scanning, in which the body is scanned continuously in a helical fashion. MPR (multiplanar reconstruction) can be performed using this data to generate images in arbitrary sectional planes, making it possible to obtain sagittal-plane images of the highest quality, which is useful for surgical planning. However, the procedures involved are rather complicated. Therefore, this study was conducted to investigate conditions for standardization of sagittal-plane MPR examinations performed using Xvigor CT scanners and Xtension. The results showed that a slice interval of 1 mm, no imaging filter, a zooming factor of 1.5, a window level of 350, and a window width of 3500 are the optimal imaging conditions. The stapes can be visualized in 70% of cases with sagittal-plane MPR based on axial images, and can be recognized at surgery in 75% or more of cases. Images of consistent quality can be obtained by standardizing the conditions for sagittal-plane MPR, which should prove advantageous in the clinical setting. (author)

  14. Methods of Measuring Stress Relaxation in Composite Tape Springs

    Science.gov (United States)

    2015-03-26

    10 3. Cure Cycle Recommended for Patz F7 Prepreg . . . . . . . . . . . . . . . . . . . . . 17 4. Typical Stress...unique and dimensionally complex parts. Hand lay-up is the method by which prepreg tape or fibers are laid down and then the matrix is then ‘painted’ on...structure. Hand lay-up using a prepreg tape stands out as the inexpensive choice for the unique low number production of tape springs and should

  15. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R.; Keene, J.S.; Graf, B.K.

    1992-01-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.)

  16. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R. (Univ. of Wisconsin Hospital and Clinics, Dept. of Radiology, Madison, WI (United States)); Keene, J.S.; Graf, B.K. (Univ. of Wisconsin Hospital and Clinics, Div. of Orthopedic Surgery, Madison, WI (United States))

    1992-02-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.).

  17. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    Science.gov (United States)

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  18. Ankle taping does not impair performance in jump or balance tests.

    Science.gov (United States)

    Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.

  19. Noninvasive Optoelectronic Assessment of Induced Sagittal Imbalance Using the Vicon System.

    Science.gov (United States)

    Ould-Slimane, Mourad; Latrobe, Charles; Michelin, Paul; Chastan, Nathalie; Dujardin, Franck; Roussignol, Xavier; Gauthé, Rémi

    2017-06-01

    Spinal diseases often induce gait disorders with multifactorial origins such as lumbar pain, radicular pain, neurologic complications, or spinal deformities. However, radiography does not permit an analysis of spinal dynamics; therefore, sagittal balance dynamics during gait remain largely unexplored. This prospective and controlled pilot study assessed the Vicon system for detecting sagittal spinopelvic imbalance, to determine the correlations between optoelectronic and radiographic parameters. Reversible anterior sagittal imbalance was induced in 24 healthy men using a thoracolumbar corset. Radiographic, optoelectronic, and comparative analyses were conducted. Corset wearing induced significant variations in radiographic parameters indicative of imbalance; the mean C7-tilt and d/D ratio increased by 15° ± 7.4° and 359%, respectively, whereas the mean spinosacral angle decreased by 16.8° ± 8° (all P imbalance; the mean spinal angle increased by 15.4° ± 5.6° (P imbalance detected using the Vicon system. Optoelectronic C7'S1' correlated with radiographic C7-tilt and d/D ratio. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. A previously unreported variant of the synostotic sagittal suture: Case report and review of salient literature

    Directory of Open Access Journals (Sweden)

    Madison Budinich

    2016-12-01

    Full Text Available Introduction: Sagittal synostosis is a rare congenital disease caused by the premature fusion of the sagittal suture. Craniosynostosis occurs for a variety of reasons, different for every case, and often the etiology is unclear but the anomaly can frequently be seen as part of Crouzon's or Apert's syndromes. Herein, we discuss a rare case of craniosynostosis where the patient presented with a, to our knowledge, a previously undescribed variant of sagittal synostosis. Case report: A 3-month-old female infant presented to a craniofacial clinic for a consultation regarding an abnormal head shape. Images of the skull were performed, demonstrating that the patient had craniosynostosis. The patient displayed no other significant symptoms besides abnormalities in head shape. The sagittal suture was found to extend into the occipital bone where it was synostotic. Conclusion: To our knowledge, a synostotic sagittal suture has not been reported that extended posteriorly it involve the occipital bone. Those who interpret imaging or operate on this part of the skull should consider such a variation. Keywords: Anatomy, Craniosynostosis, Skull, Malformation, Pediatrics

  1. Pediatric Tape: Accuracy and Medication Delivery in the National Park Service

    Directory of Open Access Journals (Sweden)

    Danielle D. Campagne

    2015-10-01

    Full Text Available Introduction: The objective is to evaluate the accuracy of medication dosing and the time to medication administration in the prehospital setting using a novel length-based pediatric emergency resuscitation tape. Methods: This study was a two-period, two-treatment crossover trial using simulated pediatric patients in the prehospital setting. Each participant was presented with two emergent scenarios; participants were randomized to which case they encountered first, and to which case used the National Park Service (NPS emergency medical services (EMS length-based pediatric emergency resuscitation tape. In the control (without tape case, providers used standard methods to determine medication dosing (e.g. asking parents to estimate the patient’s weight; in the intervention (with tape case, they used the NPS EMS length-based pediatric emergency resuscitation tape. Each scenario required dosing two medications (Case 1 [febrile seizure] required midazolam and acetaminophen; Case 2 [anaphylactic reaction] required epinephrine and diphenhydramine. Twenty NPS EMS providers, trained at the Parkmedic/Advanced Emergency Medical Technician level, served as study participants. Results: The only medication errors that occurred were in the control (no tape group (without tape: 5 vs. with tape: 0, p=0.024. Time to determination of medication dose was significantly shorter in the intervention (with tape group than the control (without tape group, for three of the four medications used. In case 1, time to both midazolam and acetaminophen was significantly faster in the intervention (with tape group (midazolam: 8.3 vs. 28.9 seconds, p=0.005; acetaminophen: 28.6 seconds vs. 50.6 seconds, p=0.036. In case 2, time to epinephrine did not differ (23.3 seconds vs. 22.9 seconds, p=0.96, while time to diphenhydramine was significantly shorter in the intervention (with tape group (13 seconds vs. 37.5 seconds, p<0.05. Conclusion: Use of a length-based pediatric emergency

  2. Benefits of sagittal-oblique MRI reconstruction of anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Nenezić, D.

    2015-01-01

    Full text: MRI examination of the anterior cruciate ligament (ACL) of the knee gives valuable information for conventional, physiatrist and/or arthroscopic microinvasiv treatment. three planar MRI examination and 3D reconstructions are highly precise in the analysis of the intra and periarticular structures, with exceptions of anterior cruciate ligament. Direct contact with the roof of the intercondilar fossa (in the full extension during the examination) and its specific orientation makes visualization of ACL diagnostically problematic. In a one year period precise protocol for MRI visualization of ACL was tested and applied as “Sagittal Oblique MRI Reconstruction”. In short, it has been Angled biplanar reconstruction in the parasagital and paratransversal planes (patientrelated and arbitrary selected in full extension), on T2, 2mm slice and 0,2 mm gap. 153 MRI examinations of the patients with lesions of the ACL were included in the study in the Clinical Center of Montenegro during 2005 year. Beside standard Knee MRI protocol all patients had the Sagittal Oblique MRI reconstruction of ACL and the Flexion MRI examination, to compare with. The Sagittal Oblique MRI reconstruction of ACL it is adapted to the concrete morphology of the patients ACL and it does not depend of the volume of the examined knee. In comparison with the Standard Knee MRI protocol and with the Flexion MRI examination, the Sagittal Oblique MRI reconstruction of ACL takes less time to perform, and the ligament is shown in fool length at three to five slices, which is more than with the both compared protocols. Sagittal Oblique MRI Reconstruction of ACL is therefore patient dependable, orientated in shape of concrete ligament of the patient’s knee. In combination with age, occupation, physical activity and level of patients while to contribute in healing process, the Sagittal Oblique MRI reconstruction of ACL contribute to scholastic approach, as highest benefit to patients with

  3. INFLUENCE OF THE SAGITTAL BALANCE ON THE CLINICAL OUTCOME IN SPINAL FUSION

    Directory of Open Access Journals (Sweden)

    Marcela Almeida Campos Coutinho

    2016-03-01

    Full Text Available ABSTRACT Objective: Evaluates which radiographic parameters of the sagittal and spinopelvic balance influence the clinical and functional outcomes of a sample of patients undergoing spinal fusion. Methods: We studied 32 patients who underwent spinal fusion. Radiographs of the total spine were obtained from all patients. The clinical and functional parameters studied were analysis of pain by visual analogic scale (VAS and Oswestry and SRS-30 questionnaires. We analyzed the correlation between the clinical and functional parameters and radiographic parameters of the sagittal and spinopelvic balance. Results: There was no significant correlation between parameters pelvic incidence (PI, pelvic tilt (PT, lumbar lordosis (LL and difference between PI and LL (PI-LL and clinical parameters (p > 0.05 and r <0.2. Significant correlation were identified only between Sagittal Vertical Axis (SVA and Satisfaction with Treatment domain of SRS-30 (r = 0.402 e p = 0.023 and between thoracic kyphosis (TK and the total SRS-30 (r = 0.419 and p = 0.017. Conclusions: According to the study results, it was not possible to precisely characterize the role of the parameters of the sagittal and spinopelvic balance in the post-operative analysis of the clinical outcome of spinal fusion. There was a significant correlation only between SVA and the Satisfaction with Treatment domain of SRS-30 and between TK and total SRS-30.

  4. Tracking errors in tractography of the gastrocnemius muscle. A comparison between the transverse and sagittal planes

    International Nuclear Information System (INIS)

    Aoki, Takako; Tohdoh, Yukihiro; Tawara, Noriyuki; Okuwaki, Toru; Horiuchi, Akira; Itagaki, Takuma; Niitsu, Mamoru

    2010-01-01

    In scans taken in conventional direction, tracking errors may occur when using a streamline-based algorithm for the tractography of the gastrocnemius muscle. To solve errors in tracking, we applied tractography to the musculotendinous junction and performed fiber tracking on the gastrocnemius muscle of 10 healthy subjects with their written informed consent. We employed a spin-echo diffusion tensor imaging (SE-DTI) sequence with 6-direction diffusion gradient sensitization and acquired DTI images at 1.5 tesla using a body array coil with parallel imaging. We compared tractography obtained in the transverse and sagittal planes using anatomical reference and found that the gastrocnemius muscle and musculotendinous junction were significantly better visualized on sagittal scans and in 3 regions of interest. We utilized Mann-Whitney U-test to determine significant differences between rates of concordance (P 2 value of skeletal muscle is around 50 ms, and TE should be as short as possible. A streamline-based algorithm is based on the continuity of a vector. It is easy to take running of the muscle fiber in sagittal scan. Therefore, tracking error is hard to occur. In conclusion, sagittal scanning may be one way to eliminate tracking errors in the tractography of the gastrocnemius muscle. Tracking errors were smaller with sagittal scans than transverse scans, and sagittal scans allow better fiber tracking. (author)

  5. Measurement and Finite Element Model Validation of Immature Porcine Brain-Skull Displacement during Rapid Sagittal Head Rotations.

    Science.gov (United States)

    Pasquesi, Stephanie A; Margulies, Susan S

    2018-01-01

    Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain-skull displacement in the neonatal piglet head ( n  = 3) at the sagittal midline during six rapid non-impact rotations (two rotations per specimen) with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain-skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain-skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain-skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain-skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations.

  6. Measurement and Finite Element Model Validation of Immature Porcine Brain–Skull Displacement during Rapid Sagittal Head Rotations

    Science.gov (United States)

    Pasquesi, Stephanie A.; Margulies, Susan S.

    2018-01-01

    Computational models are valuable tools for studying tissue-level mechanisms of traumatic brain injury, but to produce more accurate estimates of tissue deformation, these models must be validated against experimental data. In this study, we present in situ measurements of brain–skull displacement in the neonatal piglet head (n = 3) at the sagittal midline during six rapid non-impact rotations (two rotations per specimen) with peak angular velocities averaging 51.7 ± 1.4 rad/s. Marks on the sagittally cut brain and skull/rigid potting surfaces were tracked, and peak values of relative brain–skull displacement were extracted and found to be significantly less than values extracted from a previous axial plane model. In a finite element model of the sagittally transected neonatal porcine head, the brain–skull boundary condition was matched to the measured physical experiment data. Despite smaller sagittal plane displacements at the brain–skull boundary, the corresponding finite element boundary condition optimized for sagittal plane rotations is far less stiff than its axial counterpart, likely due to the prominent role of the boundary geometry in restricting interface movement. Finally, bridging veins were included in the finite element model. Varying the bridging vein mechanical behavior over a previously reported range had no influence on the brain–skull boundary displacements. This direction-specific sagittal plane boundary condition can be employed in finite element models of rapid sagittal head rotations. PMID:29515995

  7. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

    Science.gov (United States)

    Han, Hyuk-Soo; Kang, Seung-Baik; Jo, Chris H; Kim, Sun-Hong; Lee, Jung-Ha

    2010-10-01

    Experimental and clinical studies on the accuracy of the intramedullary alignment method have produced different results, and few have addressed accuracy in the sagittal plane. Reported deviations are not only attributable to the alignment method but also to radiological errors. The purpose of this study was to evaluate the accuracy of the intramedullary alignment method in the sagittal plane using computed tomography (CT) and 3-dimensional imaging software. Thirty-one TKAs were performed using an intramedullary alignment method involving the insertion of a long 8-mm diameter rod into the medullary canal to the distal metaphysis of the tibia. All alignment instruments were set to achieve an ideal varus/valgus angle of 0° in the coronal plane and a tibial slope of 0° in the sagittal plane. The accuracy of the intramedullary alignment system was assessed by measuring the coronal tibial component angle and sagittal tibial slope angles, i.e., angles between the tibial anatomical axis and the tangent to the medial and lateral tibial plateau or the cut-surface. The mean coronal tibial component angle was 88.5° ± 1.2° and the mean tibial component slope in the sagittal plane was 1.6° ± 1.2° without anterior slope. Our intramedullary tibial alignment method, which involves passing an 8-mm diameter long rod through the tibial shaft isthmus, showed good accuracy (less than 3 degrees of variation and no anterior slope) in the sagittal plane in neutral or varus knees.

  8. Conjoined lumbosacral nerve roots compromised by disk herniation: sagittal shoulder sign for the preoperative diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Chang Ho [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Korea University College of Medicine, Department of Radiology, Anam Hospital, Seoul (Korea); Shin, Myung Jin; Kim, Sung Moon; Lee, Sang Hoon; Kim, Hee Kyung; Ryu, Jeong Ah [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Lee, Choon-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Orthopedic Surgery, Seoul (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Department of Radiology, Kangwon (Korea)

    2008-03-15

    The objective was to determine the importance of the ''sagittal shoulder sign'' on magnetic resonance (MR) images for the diagnosis of conjoined lumbosacral nerve roots (CLNR) that are compromised by herniated disks. Magnetic resonance images of 11 patients (6 men and 5 women; age range, 25-71 years; average age, 48.7 years) with surgically proven CLNR, which was compromised by herniated disks, were retrospectively evaluated by two musculoskeletal radiologists. MR images were evaluated for the presence or absence of the sagittal shoulder sign - a vertical structure connecting two consecutive nerve roots and overlying disk on the sagittal MR images. The radiologists noted the type of accompanying disk herniation and bony spinal canal changes, as well as other characteristic MR features of CLNR, the common passage of two consecutive nerve roots through the neural foramen on axial MR images. The sagittal shoulder sign was identified with a mean frequency of 90.9% by the two observers (in 10 of 11 patients). The common passage of two consecutive nerve roots through the neural foramen on axial MR images was identified with a mean frequency of 59.1% (in 7 and 6 out of 11 patients, by observers 1 and 2, respectively). Good interobserver agreement for the sagittal shoulder sign was present (k = 0.621, p < 0.05). Observation of the sagittal shoulder sign may prove helpful for diagnosing CLNR in patients with disk herniation. In particular, this sign appears to be useful when there is no evidence of CLNR on axial MR images. (orig.)

  9. Delamination behaviour in differently copper laminated REBCO coated conductor tapes under transverse loading

    Energy Technology Data Exchange (ETDEWEB)

    Gorospe, Alking [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Department of Engineering, Aurora State College of Technology, Baler Aurora 3200 (Philippines); Nisay, Arman [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Shin, Hyung-Seop, E-mail: hsshin@andong.ac.kr [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of)

    2014-09-15

    Highlights: • I{sub c} degradation behavior under transverse tension loading in different CC tape structure. • Weibull distribution analysis applied on delamination mechanism of CC tape. • Delamination mechanism on CC tapes depending on copper lamination type. • SEM and WDS mapping analysis of delamination sites under transverse loading. - Abstract: Laminated HTS coated conductor (CC) tapes having a unique multi-layer structure made them vulnerable when exposed to transverse loading. Electromechanical transport properties of these CC tapes can be affected by excessive transverse stresses. Due to the coefficient of thermal expansion (CTE) mismatch and incompatibility among constituent materials used in coil applications, delamination among layers occurs and causes critical current, I{sub c} degradation in the CC tapes. In this study, the delamination behaviors in copper (Cu) solder-laminated CC tapes by soldering and surround Cu-stabilized ones by electroplating under transverse tension loading were investigated. Similarly to the surround Cu-stabilized CC tapes in our previous reports, the Cu solder-laminated CC tapes also showed an abrupt and gradual I{sub c} degradation behavior. However, the Cu solder-laminated CC tapes showed different delamination morphologies as compared to the surround Cu-stabilized CC tapes; the superconducting side and the substrate side of the Cu solder laminated CC tapes were totally separated by delamination. On the other hand, the brass laminate did not show any significant effect on the delamination strength when it is added upon the surround Cu-stabilized CC tapes.

  10. Adhesive tape exfoliation

    DEFF Research Database (Denmark)

    Bohr, Jakob

    2015-01-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful...

  11. Kinesio® Tape Barrier Does Not Inhibit Intramuscular Cooling During Cryotherapy.

    Science.gov (United States)

    Lyman, Katie J; McCrone, Michael; Hanson, Thomas A; Mellinger, Christopher D; Gange, Kara

    2018-05-29

    Allied health care professionals commonly apply cryotherapy as treatment for acute musculoskeletal trauma and the associated symptoms. Understanding the impact of a tape barrier on intramuscular temperature can assist in determining treatment duration for effective cryotherapy. To determine whether Kinesio® Tape acts as a barrier that affects intramuscular temperature during cryotherapy application. A repeated-measures, counterbalanced design in which the independent variable was tape application and the dependent variable was muscle temperature as measured by thermocouples placed 1 cm beneath the adipose layer. Additional covariates for robustness were BMI and adipose thickness. University research laboratory. 19 male college students with no contraindications to cryotherapy, no known sensitivity to Kinesio® Tape, and no reported quadriceps injury within the past six months. Topical cryotherapy: crushed-ice bags of 1 kg and 0.5 kg. Intramuscular temperature. The tape barrier had no statistically significant effect on muscle temperature. The pattern of temperature change was indistinguishable between participants with and without tape application. Findings suggest health care professionals can combine cryotherapy with a Kinesio® Tape application without any need for adjustments to cryotherapy duration.

  12. Enhancement of turbulent flow heat transfer in a tube with modified twisted tapes

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Y.G.; Zhao, C.H.; Song, C.F. [College of Environmental Science and Engineering, Taiyuan University of Technology, Taiyuan (China)

    2012-12-15

    Numerical simulations were performed to study the fluid flow and heat transfer in a tube with staggered twisted tapes with central holes. In the range of Reynolds numbers between 6000 and 28 000, the modified twisted tapes increased the Nusselt number by 76.2 {proportional_to} 149.7 % and the friction factor by 380.2 {proportional_to} 443.8 % compared to the smooth tube. Compared to the typical twisted tapes, the modified twisted tapes produced an acceleration flow through the triangle regions leading to the enhancement of heat transfer, and the holes in the modified tapes reduced the severe pressure loss. It was found that the modified twisted tapes decreased the friction factor by 8.0 {proportional_to} 16.1 % and enhanced the heat transfer by 34.1 {proportional_to} 46.8 % in comparison with the typical tapes. These results indicated that the performance ratio values of the tube with modified twisted tapes were higher than 1.0 in the range of Reynolds numbers studied. The computed performance ratios of the tube with modified twisted tapes were much higher than those of the tube with typical twisted tapes. This means that the integrated performance of the tube with staggered twisted tapes with central holes is superior to that of the tube with typical twisted tapes. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. Molten carbonate fuel cell integral matrix tape and bubble barrier

    International Nuclear Information System (INIS)

    Reiser, C.A.; Maricle, D.L.

    1983-01-01

    A molten carbonate fuel cell matrix material is described made up of a matrix tape portion and a bubble barrier portion. The matrix tape portion comprises particles inert to molten carbonate electrolyte, ceramic particles and a polymeric binder, the matrix tape being flexible, pliable and having rubber-like compliance at room temperature. The bubble barrier is a solid material having fine porosity preferably being bonded to the matrix tape. In operation in a fuel cell, the polymer binder burns off leaving the matrix and bubble barrier providing superior sealing, stability and performance properties to the fuel cell stack

  14. Fabrication of laminated Bi-2212/Ag multifilamentary tape

    Science.gov (United States)

    Yuan, D.-W.; Majer, W. J.; Francavilla, T. L.

    2000-03-01

    The powder-in-tube (PIT) process has been successfully used to make long lengths of Ag-sheathed oxide superconductors. A modified PIT approach is proposed to fabricate conductors with laminated Bi-2212 configurations. Ag/Bi-2212 tapes consisting of seven laminae were produced with various thicknesses ranging from 0.38 to 0.25 mm. The use of a turkshead was found to be beneficial, yielding tapes with good dimensional integrity and consistency. Critical current density (Jc ) values greater than 105 A cm-2 (0.01 T and Bicons/Journals/Common/perp" ALT="perp" ALIGN="TOP"/> tape surface) have been attained for tapes of different thicknesses. Nonetheless, Jc was found to be related to the average thickness of individual Bi-2212 lamina. It is believed that excessive cold working accounts for the decrease in Jc with decreasing size below a threshold value. The enhancement of Jc is attributed to the high Bi-2212 grain alignment along the Ag-oxide interfaces and uniform dimensions within the laminate conductors.

  15. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    International Nuclear Information System (INIS)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B.; Brooks, Jeffrey J.

    2018-01-01

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  16. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B. [Yale New Haven Health Bridgeport Hospital, Bridgeport, CT (United States); Brooks, Jeffrey J. [Orthopedic Surgery and Sports Medicine Center, New Canaan, CT (United States)

    2018-04-15

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  17. The relationship between changes of cervical sagittal alignment after anterior cervical discectomy and fusion and spino-pelvic sagittal alignment under roussouly classification: a four-year follow-up study.

    Science.gov (United States)

    Huang, Dong-Ning; Yu, Miao; Xu, Nan-Fang; Li, Mai; Wang, Shao-Bo; Sun, Yu; Jiang, Liang; Wei, Feng; Liu, Xiao-Guang; Liu, Zhong-Jun

    2017-02-20

    Anterior cervical discectomy and fusion (ACDF) is widely used in the treatment of cervical degenerative disease; however, the variation of cervical sagittal alignment changes after ACDF has been rarely explored. The purpose of this study is to determine the relationship between changes of cervical sagittal alignment after ACDF and spino-pelvic sagittal alignment under Roussouly classification. A cohort of 133 Chinese cervical spondylotic patients who received ACDF from 2011 to 2012 was recruited. All patients were categorized with Roussouly Classification. Lateral X-ray images of global spine were obtained, and preoperative and postoperative parameters were measured and analyzed, including C2-C7 angles (C2-C7), C0-C7 angles (C0-C7), external auditory meatus (EAM) tilt, sacral slope (SS), thoracic kyphosis (TK), lumbar lordosis (LL), spinal sacral angles (SSA), Superior adjacent inter-vertebral angle (SAIV), inferior adjacent inter-vertebral angle (IAIV) and et al. The Wilcoxon signed-rank test was used for intragroup comparisons preoperatively and at postoperative 48 months. Among the parameters, C2-C7 and C0-C7 showed significant increase, while EAM TK, and IAIV decreased significantly. In type I, EAM and TK decreased significantly, however SS showed a significant increase; in type II, TK showed a significant decrease, but SSA showed a significant increase; in type III, a significant increase of C0-C7 was observed with a significant decrease in EAM, nevertheless, LL, SS and SSA showed significant decreases; and in type IV, C2-C7 showed a significant increase and EAM decreased significantly. The percentage of lordotic alignment in cervical spine increased, which was presenting in type I, III and IV. Nevertheless, the amount of patients with straight cervical alignment increased in type II. The backward movement of head occurs is the compensatory mechanism in cervical sagittal alignment modifications after ACDF. The compensatory alteration of spino-pelvic sagittal

  18. The relationship between changes of cervical sagittal alignment after anterior cervical discectomy and fusion and spino-pelvic sagittal alignment under roussouly classification: a four-year follow-up study

    Directory of Open Access Journals (Sweden)

    Dong-Ning Huang

    2017-02-01

    Full Text Available Abstract Background Anterior cervical discectomy and fusion (ACDF is widely used in the treatment of cervical degenerative disease; however, the variation of cervical sagittal alignment changes after ACDF has been rarely explored. The purpose of this study is to determine the relationship between changes of cervical sagittal alignment after ACDF and spino-pelvic sagittal alignment under Roussouly classification. Methods A cohort of 133 Chinese cervical spondylotic patients who received ACDF from 2011 to 2012 was recruited. All patients were categorized with Roussouly Classification. Lateral X-ray images of global spine were obtained, and preoperative and postoperative parameters were measured and analyzed, including C2–C7 angles (C2–C7, C0–C7 angles (C0–C7, external auditory meatus (EAM tilt, sacral slope (SS, thoracic kyphosis (TK, lumbar lordosis (LL, spinal sacral angles (SSA, Superior adjacent inter-vertebral angle (SAIV, inferior adjacent inter-vertebral angle (IAIV and et al. The Wilcoxon signed-rank test was used for intragroup comparisons preoperatively and at postoperative 48 months. Results Among the parameters, C2–C7 and C0–C7 showed significant increase, while EAM TK, and IAIV decreased significantly. In type I, EAM and TK decreased significantly, however SS showed a significant increase; in type II, TK showed a significant decrease, but SSA showed a significant increase; in type III, a significant increase of C0–C7 was observed with a significant decrease in EAM, nevertheless, LL, SS and SSA showed significant decreases; and in type IV, C2–C7 showed a significant increase and EAM decreased significantly. The percentage of lordotic alignment in cervical spine increased, which was presenting in type I, III and IV. Nevertheless, the amount of patients with straight cervical alignment increased in type II. Conclusion The backward movement of head occurs is the compensatory mechanism in cervical sagittal alignment

  19. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    Science.gov (United States)

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  20. Sputtered thin films for high density tape recording

    NARCIS (Netherlands)

    Nguyen, L.T.

    This thesis describes the investigation of sputtered thin film media for high density tape recording. As discussed in Chapter 1, to meet the tremendous demand of data storage, the density of recording tape has to be increased continuously. For further increasing the bit density the key factors are:

  1. StorageTek RedWood SD-3 tape drive

    CERN Multimedia

    1995-01-01

    A helical scan recording drive, with a high-speed rotating head sweeping across the tape every few micrometers. Based on a professional video recording system, modified to be suitable for digital data recording. These are commonly used with large computer systems, typically in conjunction with a robotic tape library.

  2. Accuracy of the sagittal vertical axis in a standing lateral radiograph as a measurement of balance in spinal deformities

    NARCIS (Netherlands)

    van Royen, B.J.; Toussaint, H.M.; Kingma, I.; Bot, S.D.M.; Caspers, M.; Harlaar, J.

    1998-01-01

    Sagittal balance of the spine is becoming an important issue in the assessment of the degree of spinal deformity. On a standing lateral full- length radiograph of the spine, the plumb line, or sagittal vertical axis (SVA), can be used to determine the spinal sagittal balance. In this procedure

  3. Sagittal plane tilting deformity of the patellofemoral joint: a new concept in patients with chondromalacia patella.

    Science.gov (United States)

    Aksahin, Ertugrul; Aktekin, Cem Nuri; Kocadal, Onur; Duran, Semra; Gunay, Cüneyd; Kaya, Defne; Hapa, Onur; Pepe, Murad

    2017-10-01

    The aims of this study were to evaluate sagittal plane alignment in patients with chondromalacia patella via magnetic resonance imaging (MRI), analyse the relationships between the location of the patellar cartilaginous lesions and sagittal alignment and finally investigate the relationships between the sagittal plane malalignment and patellofemoral loadings using by finite element analysis. Fifty-one patients who were diagnosed with isolated modified Outerbridge grade 3-4 patellar chondromalacia based on MRI evaluation and 51 control subjects were evaluated. Chondromalacia patella patients were divided into three subgroups according to the chondral lesion location as superior, middle and inferior. The patella-patellar tendon angle (P-PT) was used for evaluation of sagittal alignment of patellofemoral joint. Each subgroup was compared with control group by using P-PT angle. To investigate the biomechanical effects of sagittal plane malpositioning on patellofemoral joint, bone models were created at 30°, 60° and 90° knee flexion by using mean P-PT angles, which obtained from patients with chondromalacia patellae and control subjects. The total loading and contact area values of the patellofemoral joints were investigated by finite element analysis. The mean age of all participants was 52.9 ± 8.2 years. The mean P-PT angle was significantly lower in chondromalacia group (142.1° ± 3.6°) compared to control group (144.5° ± 5.3°) (p = 0.008). Chondral lesions were located in superior, middle and inferior zones in 16, 20 and 15 patients, respectively. The mean P-PT angles in patients with superior (141.8 ± 2.7) and inferior subgroups (139.2 ± 2.3) were significantly lower than the values in the control group (p chondromalacia than in the control models at the same flexion degrees. There were increased loadings at 30° and 90° flexions in the sagittal patellar tilt models. This study revealed that sagittal plain malpositioning of the

  4. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2010-10-15

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  5. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T; Nguyen, H. D.; Takehara, K.; Etoh, T. G.

    2010-01-01

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  6. An automated magnetic tape vault at CERN computer center

    CERN Multimedia

    Claudia Marcelloni

    2008-01-01

    The rapidly changing data processing landscape the underlying long-term storage technology remains the tried and tested magnetic tape. This robust and mature technology is used to store the complete LHC data set, from which a fraction of the data is copied to overlying disk caches for fast and widespread access. The handling of the magnetic tape cartridges is now fully automated, as they are racked in vaults where they are moved between the storage shelves and the tape drives by robotic arms.

  7. Correlation Between Echodefecography and 3-Dimensional Vaginal Ultrasonography in the Detection of Perineal Descent in Women With Constipation Symptoms.

    Science.gov (United States)

    Murad-Regadas, Sthela M; Pinheiro Regadas, Francisco Sergio; Rodrigues, Lusmar V; da Silva Vilarinho, Adjra; Buchen, Guilherme; Borges, Livia Olinda; Veras, Lara B; da Cruz, Mariana Murad

    2016-12-01

    Defecography is an established method of evaluating dynamic anorectal dysfunction, but conventional defecography does not allow for visualization of anatomic structures. The purpose of this study was to describe the use of dynamic 3-dimensional endovaginal ultrasonography for evaluating perineal descent in comparison with echodefecography (3-dimensional anorectal ultrasonography) and to study the relationship between perineal descent and symptoms and anatomic/functional abnormalities of the pelvic floor. This was a prospective study. The study was conducted at a large university tertiary care hospital. Consecutive female patients were eligible if they had pelvic floor dysfunction, obstructed defecation symptoms, and a score >6 on the Cleveland Clinic Florida Constipation Scale. Each patient underwent both echodefecography and dynamic 3-dimensional endovaginal ultrasonography to evaluate posterior pelvic floor dysfunction. Normal perineal descent was defined on echodefecography as puborectalis muscle displacement ≤2.5 cm; excessive perineal descent was defined as displacement >2.5 cm. Of 61 women, 29 (48%) had normal perineal descent; 32 (52%) had excessive perineal descent. Endovaginal ultrasonography identified 27 of the 29 patients in the normal group as having anorectal junction displacement ≤1 cm (mean = 0.6 cm; range, 0.1-1.0 cm) and a mean anorectal junction position of 0.6 cm (range, 0-2.3 cm) above the symphysis pubis during the Valsalva maneuver and correctly identified 30 of the 32 patients in the excessive perineal descent group. The κ statistic showed almost perfect agreement (κ = 0.86) between the 2 methods for categorization into the normal and excessive perineal descent groups. Perineal descent was not related to fecal or urinary incontinence or anatomic and functional factors (sphincter defects, pubovisceral muscle defects, levator hiatus area, grade II or III rectocele, intussusception, or anismus). The study did not include a

  8. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    OpenAIRE

    Brendon A. Parsons; Olivia Lin Smith; Myeong Chae; Veljko Dragojlovic

    2015-01-01

    Summary In a PTFE tape phase-vanishing reaction (PV-PTFE), a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better...

  9. A new method of measurement of tension on a moving magnetic tape

    Science.gov (United States)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  10. [Efficacy of the application of kinesio tape in patients with stroke].

    Science.gov (United States)

    Ortiz-Ramirez, J; Perez-De la Cruz, S

    2017-02-16

    To review the effects achieved by the kinesio tape in patients with stroke in scientific studies published on date and to discuss these findings may be of interest to neurology. An exhaustive search in the main scientific databases using keywords such as kinesio tape, kinesiotaping, musculoskeletal tape, taping medical concept was carried out. Citations of selected articles and scientific papers published on the website of the Spanish Association of Neuromuscular Bandage were analyzed. Experimental, quasi-experimental, clinical trials and case studies published were used, without limit date, with therapeutical treatment purpose provide important results. Eight articles have met the inclusion criteria. There are eight studies that examine the effect on kinesio tape on lower limb, gait and balance in this kind of therapy, even upper limb and swallowing problems that these patients could present. The kinesio tape in neurological patients can be a complementary technique that empirically provides benefits. However, better methodological quality studies demonstrating the effects attributed to him are still needed.

  11. Recovery of recordings from heat damaged magnetic tapes

    Science.gov (United States)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  12. Modification of critical current in HTSC tape conductors by a ferromagnetic layer

    International Nuclear Information System (INIS)

    Goemoery, F; Souc, J; Seiler, E; Vojenciak, M; Granados, X

    2008-01-01

    In some applications of tape conductors from high temperature superconductors (HTSC) the magnetic field is created by the transported current itself. This is e.g. the case of power transmission cables or current leads. Quite complex distribution of local magnetic field determines then the ability of the superconducting element to carry electrical current. We have investigated how much the critical current of a tape conductor can be changed by putting a ferromagnetic layer in the vicinity of the HTSC material. Numerical procedure has been developed to resolve the current and field distribution in such superconductor-ferromagnet composite tape. Theoretical predictions have been confirmed by experiments on sample made from Bi-2223/Ag composite tape. The critical current of such tape can be improved by placing a soft ferromagnetic material at the tape's edges. On the other hand, the calculations show that the ferromagnetic substrate of YBCO coated tape reduces its self-field critical current

  13. How PE tape performs under concrete coating

    International Nuclear Information System (INIS)

    Dritt, H.J.

    1984-01-01

    The program objectives were to evaluate the performance of polyethylene tape plant coating and fusion bonded epoxy powder systems with particular respect to the following: 1. Concrete coating application procedures; 2. The shear resistance during laying and retrieving operations of the coating at the various interfaces (a) Pipe and anti-corrosion coating; (b) Anti-corrosion coating and outerwrap; (c) Overlap areas of the anti-corrosion and outerwrap layers; (d) Between concrete and the various corrosion coatings during laying and retrieving operations. 3. Resistance to damage of the coating as a consequence of cracking or slippage of the concrete weight coating. 4. Ability of various coatings to withstand the damage during concrete application by both impact and compression methods; 5. Evaluation of tape and shrink sleeve joint coatings at the cut-back area as well as performance of tape under hot asphalt coating

  14. Superior sagittal sinus thrombosis: a rare complication in a child with nephrotic syndrome

    International Nuclear Information System (INIS)

    Pirogovsky, A.; Adi, M.; Barzilai, N.; Dagan, A.; Sinai, L.; Sthoeger, D.; Tabachnik, E.

    2001-01-01

    A 2-year-old boy with new-onset nephrotic syndrome developed recurrent vomiting, apathy and papilloedema. Superior sagittal sinus thrombosis was diagnosed on cranial CT and MRI. He gradually recovered after treatment with heparin, fresh frozen plasma and warfarin with complete resolution of the thrombosis after 1 month. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome in children. Early diagnosis is essential for institution of anticoagulation therapy and a successful outcome. (orig.)

  15. Superior sagittal sinus thrombosis: a rare complication in a child with nephrotic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Pirogovsky, A.; Adi, M.; Barzilai, N. [Dept. of Radiology, Kaplan Medical Center, Rehovot (Israel); Dagan, A.; Sinai, L.; Sthoeger, D. [Div. of Paediatrics, Kaplan Medical Center, Rehovot (Israel); Tabachnik, E. [Div. of Paediatrics, Kaplan Medical Center, Rehovot (Israel); Paediatric ICU, Kaplan Hospital, Rehovot (Israel)

    2001-10-01

    A 2-year-old boy with new-onset nephrotic syndrome developed recurrent vomiting, apathy and papilloedema. Superior sagittal sinus thrombosis was diagnosed on cranial CT and MRI. He gradually recovered after treatment with heparin, fresh frozen plasma and warfarin with complete resolution of the thrombosis after 1 month. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome in children. Early diagnosis is essential for institution of anticoagulation therapy and a successful outcome. (orig.)

  16. Suprapubic micturition cystourethrography

    Energy Technology Data Exchange (ETDEWEB)

    Mohammed, S.H.

    Suprapubic micturition cystourethrography is performed by puncturing the bladder aseptically, in the midline, 1 to 2 cm above the symphysis pubis with an 18 to 21 gauge needle. The needle is pointed 10 to 15/sup 0/ cranially to avoid puncture of the trigonum and urethra. Anaesthesia, antibiotic protection, and diuretics are not necessary. In 225 examinations performed on 200 patients, the only complications noted were transient haematuria (1.5%) and slight extravasation of contrast medium through the puncture sites (8%). None required any therapeutic measures. In 4 patients puncturing of the bladder needed ultrasound guidance. The technique is ideal for the study of vesicoureteral reflux, neurogenic bladder, urethral strictures, posterior urethral valves and other urethral pathology. It is also useful in balloon catheter dilatation of urethral strictures. Suprapubic micturition cystourethrography is safe, efficient and time-saving. It is well accepted by the patients and carries little risk of urinary infection.

  17. Suprapubic micturition cystourethrography

    International Nuclear Information System (INIS)

    Mohammed, S.H.; Kamuzu Central Hospital, Lilongwe

    1988-01-01

    Suprapubic micturition cystourethrography is performed by puncturing the bladder aseptically, in the midline, 1 to 2 cm above the symphysis pubis with an 18 to 21 gauge needle. The needle is pointed 10 to 15 0 cranially to avoid puncture of the trigonum and urethra. Anaesthesia, antibiotic protection, and diuretics are not necessary. In 225 examinations performed on 200 patients, the only complications noted were transient haematuria (1.5%) and slight extravasation of contrast medium through the puncture sites (8%). None required any therapeutic measures. In 4 patients puncturing of the bladder needed ultrasound guidance. The technique is ideal for the study of vesicoureteral reflux, neurogenic bladder, urethral strictures, posterior urethral valves and other urethral pathology. It is also useful in balloon catheter dilatation of urethral strictures. Suprapubic micturition cystourethrography is safe, efficient and time-saving. It is well accepted by the patients and carries little risk of urinary infection. (orig.)

  18. Estudo comparativo por ressonância magnética de púbis entre atletas e sedentários assintomáticos Comparative study between the pubis of asymptomatic athletes and non-athletes with MRI

    Directory of Open Access Journals (Sweden)

    Rodrigo Castelo Branco

    2010-01-01

    Full Text Available OBJETIVO: Comparar os achados na ressonância magnética do púbis de atletas profissionais de futebol, sem histórico ou clínica de pubalgia, com sedentários também assintomáticos, determinando a prevalência de alterações compatíveis com sobrecarga púbica. MÉTODOS: Dezenove atletas profissionais de futebol, sem queixas álgicas na região púbica, e 17 sedentários, também assintomáticos, foram submetidos à ressonância magnética do púbis. Os resultados dos exames foram analisados quanto à presença de alterações degenerativas, edema medular ósseo e tendinopatia, comparando ambos os grupos estudados. RESULTADOS: Foi encontrada alta prevalência de edema ósseo e tendinopatia, bem como alterações degenerativas da sínfise púbica no grupo de atletas, encontrando-se valores maiores de odds ratio e risco relativo, com significância estatística na população estudada. CONCLUSÃO: Atletas profissionais de futebol apresentam maior risco de desenvolver alterações na região púbica, evidenciadas na ressonância magnética, se comparados a indivíduos sedentários. Estes achados não são obrigatoriamente causa de pubalgia, estando provavelmente relacionados a esforço intenso.OBJECTIVE: To compare the magnetic resonance imaging findings of the pubis of professional soccer players, without history of or clinical groin pain, and non-athletes, also without symptoms, determining the prevalence of changes compatible with pubic overload. METHODS: Nineteen professional soccer players without complaints of groin pain and seventeen non-athletes, also asymptomatic, underwent pubic magnetic resonance images. Exam findings were analyzed for the presence of degenerative changes, medullar edema and tendinopathy, comparing both groups. RESULTS: High prevalence of bone edema, tendinopathy and degenerative findings in the pubic symphysis was seen in athletes, with statistically significant higher odds ratios and relative risk for the

  19. Outcome of transvaginal mesh and tape removed for pain only.

    Science.gov (United States)

    Hou, Jack C; Alhalabi, Feras; Lemack, Gary E; Zimmern, Philippe E

    2014-09-01

    Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  20. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    Directory of Open Access Journals (Sweden)

    Brendon A. Parsons

    2015-06-01

    Full Text Available In a PTFE tape phase-vanishing reaction (PV-PTFE, a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better describe the process of solvent transport in PV-PTFE bromination reactions. Though PTFE tape has been reported as impermeable to some compounds, such as dimethyl phthalate, solvent adsorption to the tape altered its permeability and allowed diffusion through channels of solvent within the PTFE tape. In this case, the solvent-filled pores of the PTFE tape are chemically more akin to the adsorbed solvent rather than to the PTFE fluorous structure. The solvent uptake effect, which was frequently observed in the course of PV-PTFE reactions, can be related to the surface tension of the solvent and the polarity of the solvent relative to the reagent. The lack of pores in bulk PTFE prevents solvents from altering its permeability and, therefore, bulk PTFE is impermeable to most solvents and reagents. However, bromine, which is soluble in liquid fluorous media, diffused through the bulk PTFE. A better understanding of the PTFE phase barrier will make it possible to further optimize the PV-PTFE reaction design.

  1. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-01-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane. Key points An increased shoe collar height effectively reduced ankle joint ROM in the sagittal plane in weight-bearing dorsiflexion maneuver. Shoe collar height did not affect sagittal plane ankle kinematics and had no effect on performance during realistic jumping. Shoe collar height can affect the ankle plantarflexion torque and peak power during the push-off phase in lay-up jump. PMID:29238255

  2. Guinea-pig interpubic joint (symphysis pubica relaxation at parturition: Underlying cellular processes that resemble an inflammatory response

    Directory of Open Access Journals (Sweden)

    Muñoz-de-Toro Mónica

    2003-11-01

    Full Text Available Abstract Background At term, cervical ripening in coordination with uterine contractions becomes a prerequisite for a normal vaginal delivery. Currently, cervical ripening is considered to occur independently from uterine contractions. Many evidences suggest that cervical ripening resembles an inflammatory process. Comparatively little attention has been paid to the increased flexibility of the pelvic symphysis that occurs in many species to enable safe delivery. The aim of this study was to investigate whether the guinea-pig interpubic joint relaxation process observed during late pregnancy and parturition resembles an inflammatory process. Methods Samples of pubic symphysis were taken from pregnant guinea-pigs sacrificed along gestation, parturition and postpartum. Serial sections of paraffin-embedded tissues were used to measure the interpubic distance on digitalized images, stained with Giemsa to quantify leukocyte infiltration and to describe the vascular area changes, or studied by the picrosirius-polarization method to evaluate collagen remodeling. P4 and E2 serum levels were measured by a sequential immunometric assay. Results Data showed that the pubic relaxation is associated with an increase in collagen remodeling. In addition, a positive correlation between E2 serum levels and the increase in the interpubic distance was found. On the other hand, a leukocyte infiltration in the interpubic tissue around parturition was described, with the presence of almost all inflammatory cells types. At the same time, histological images show an increase in vascular area (angiogenesis. Eosinophils reached their highest level immediately before parturition; whereas for the neutrophilic and mononuclear infiltration higher values were recorded one day after parturition. Correlation analysis showed that eosinophils and mononuclear cells were positively correlated with E2 levels, but only eosinophilic infiltration was associated with collagen remodeling

  3. Sagittal alignment and complications following lumbar 3-column osteotomy: does the level of resection matter?

    Science.gov (United States)

    Ferrero, Emmanuelle; Liabaud, Barthelemy; Henry, Jensen K; Ames, Christopher P; Kebaish, Khaled; Mundis, Gregory M; Hostin, Richard; Gupta, Munish C; Boachie-Adjei, Oheneba; Smith, Justin S; Hart, Robert A; Obeid, Ibrahim; Diebo, Bassel G; Schwab, Frank J; Lafage, Virginie

    2017-11-01

    OBJECTIVE Three-column osteotomy (3CO) is a demanding technique that is performed to correct sagittal spinal malalignment. However, the impact of the 3CO level on pelvic or truncal sagittal correction remains unclear. In this study, the authors assessed the impact of 3CO level and postoperative apex of lumbar lordosis on sagittal alignment correction, complications, and revisions. METHODS In this retrospective study of a multicenter spinal deformity database, radiographic data were analyzed at baseline and at 1- and 2-year follow-up to quantify spinopelvic alignment, apex of lordosis, and resection angle. The impact of 3CO level and apex level of lumbar lordosis on the sagittal correction was assessed. Logistic regression analyses were performed, controlling for cofounders, to investigate the effects of 3CO level and apex level on intraoperative and postoperative complications as well as on the need for subsequent revision surgery. RESULTS A total of 468 patients were included (mean age 60.8 years, mean body mass index 28.1 kg/m 2 ); 70% of patients were female. The average 3CO resection angle was 25.1° and did not significantly differ with regard to 3CO level. There were no significant correlations between the 3CO level and amount of sagittal vertical axis or pelvic tilt correction. The postoperative apex level significantly correlated with greater correction of pelvic tilt (2° per more caudal level, R = -0.2, p = 0.006). Lower-level 3CO significantly correlated with revisions for pseudarthrosis (OR = 3.88, p = 0.001) and postoperative motor deficits (OR = 2.02, p = 0.026). CONCLUSIONS In this study, a more caudal lumbar 3CO level did not lead to greater sagittal vertical axis correction. The postoperative apex of lumbar lordosis significantly impacted pelvic tilt. 3CO levels that were more caudal were associated with more postoperative motor deficits and revisions.

  4. Bad splits in bilateral sagittal split osteotomy: systematic review of fracture patterns.

    Science.gov (United States)

    Steenen, S A; Becking, A G

    2016-07-01

    An unfavourable and unanticipated pattern of the mandibular sagittal split osteotomy is generally referred to as a 'bad split'. Few restorative techniques to manage the situation have been described. In this article, a classification of reported bad split pattern types is proposed and appropriate salvage procedures to manage the different types of undesired fracture are presented. A systematic review was undertaken, yielding a total of 33 studies published between 1971 and 2015. These reported a total of 458 cases of bad splits among 19,527 sagittal ramus osteotomies in 10,271 patients. The total reported incidence of bad split was 2.3% of sagittal splits. The most frequently encountered were buccal plate fractures of the proximal segment (types 1A-F) and lingual fractures of the distal segment (types 2A and 2B). Coronoid fractures (type 3) and condylar neck fractures (type 4) have seldom been reported. The various types of bad split may require different salvage approaches. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  5. Influence of the sagittal anatomy of the pelvis on the intercrestal line position.

    Science.gov (United States)

    Horduna, M; Legaye, J

    2008-03-01

    The line joining the two iliac crests is classically regarded as the anatomical landmark determining the inter-vertebral space L4-L5 for the spinal punctures. Its variability has been reported but never related to predictive clinical anatomic factors identifying patients groups in which there is increased risk of miscalculation of the spinal level. Two sagittal pelvic anatomical angles, called 'pelvic incidence' and 'pelvic lordosis' were measured on lateral X-rays of the pelvis of 132 normal individuals and 49 spondylolysis patients. The values were compared with the sagittal projection of the intercrestal line on the disco-vertebral lumbar structures. A strict relation was observed between this projection of the intercrestal line and the sagittal pelvic anatomical angles. The greater the pelvic incidence, the higher the intercrestal line was projected, all the more in patients with spondylolysis with a listhesis or a disc narrowing. The relation between the pelvic sagittal angles and the intercrestal line projection explains the variability described for this anatomical landmark. It implies precautions minimizing neurological risk in the case of a puncture carried out more cranially than expected, particularly for high values of pelvic incidence occurring in spinal pathologies such as spondylolysis, in the elderly or in the obese patients. In these cases, we recommend the use of spinal imaging during the procedure to assist selection of the desired insertion level.

  6. POSTOPERATIVE URINARY RETENTION AND EARLY REPOSITION OF TENSION-FREE VAGINAL TAPE

    Directory of Open Access Journals (Sweden)

    Marijan Lužnik

    2003-12-01

    Full Text Available Background. The purpose of this article is to show a possible method of treatment of postoperative urinary retention after an initial tension-free vaginal tape.Methods. From December 1999 to May 2003 we performed one hundred TVT procedures at our department, among them five women had postoperative urinary retention evaluated with catheterization. Revision and reposition of tension-free vaginal tape were performed if retention of urine was over 100 ml.Results. Urinary retention after an initial tension-free vaginal tape was successfully treated by early reposition of tension-free vaginal tape. This resulted in immediate residualfree voiding and continence, which remained unchanged at 6 week and 3 month follow-up.Conclusions. Postoperative urinary retention may be treated by reposition instead of dissection or elongation of the tension-free vaginal tape.

  7. White House Tapes of the Nixon Administration, 1971 to 1973

    Data.gov (United States)

    National Archives and Records Administration — This dataset provides information about the Nixon Administration's White House Tapes. The White House Tapes contain sound recordings of President Richard Nixon's...

  8. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an adhesive tape solvent is a device that consists of a liquid such as 1,1,2-trichloro-1,2,2-trifluoroethane...

  9. Accelerated aging studies and environmental stability of prototype tamper tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Wright, C.W. [Pacific Northwest Lab., Richland, WA (United States); Bunk, A.R. [Battelle Columbus Lab., OH (United States)] [and others

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  10. Red Tape dan Perilaku Masyarakat dalam Pelayanan Izin Usaha Perdagangan di Kota Makassar

    OpenAIRE

    Lukman, Lukman

    2015-01-01

    : Red tape as pathology has long been the focus of an expert study of bureaucracy. Early scholarly attempts conceptualized red tape at the individual level as in Merton's classic thesis (1940) about goal displacement. Waldo (1946) one man's red tape is another man's system. Kaufman (1977) one person's red tape may be another's treasured safeguard. Osborne and Gaebler (1992) good people trapped in bad systems. Bozeman and Feneey (2011) red tape is often used as a synonym of the term procedures...

  11. Delamination behaviour of GdBCO coated conductor tapes under transverse tension

    International Nuclear Information System (INIS)

    Gorospe, A.; Nisay, A.; Dizon, J.R.; Shin, H.S.

    2013-01-01

    Highlights: •Installation of a test frame which gives precisely aligned transverse load. •Investigation of I c degradation behaviour depending on the type of sample delamination. •Inhomogeneity of the CC tapes caused large variation on delamination strength. •SEM and EDS analysis of delamination sites under transverse loading. -- Abstract: The electromechanical property behaviour of 2G coated conductor (CC) tapes fabricated by multi-layer deposition process both in the in-plane and transverse direction should be understood. The CC tapes are used in the fabrication of epoxy resin-impregnated coils. In such case, the Lorentz force due to the high magnetic field applied as well as the thermal stress due to the difference in coefficient of thermal expansion (CTE) among constituent layers during cooling to cryogenic temperature will induce transversely applied load to the surface of CC tapes in coils. Hence, the CC tape should have a good mechanical property in the transverse direction in order to maintain its superior performance under magnetic field. In this study, a test frame which gives precisely aligned transverse load was devised. Using the fixture, the delamination behaviours including the delamination strength of the GdBCO CC tapes under transverse tensile loading were investigated. Large variation on the delamination strength of the CC tapes was recorded and might have resulted from the slit edge effect and the inhomogeneity of the CC tapes. The I c degradation behaviour under transverse load was related to the location where delamination occurred in the sample

  12. Symphysis-fundal height curve in the diagnosis of fetal growth deviations

    Directory of Open Access Journals (Sweden)

    Djacyr Magna Cabral Freire

    2010-12-01

    Full Text Available OBJECTIVE: To validate a new symphysis-fundal curve for screening fetal growth deviations and to compare its performance with the standard curve adopted by the Brazilian Ministry of Health. METHODS: Observational study including a total of 753 low-risk pregnant women with gestational age above 27 weeks between March to October 2006 in the city of João Pessoa, Northeastern Brazil. Symphisys-fundal was measured using a standard technique recommended by the Brazilian Ministry of Health. Estimated fetal weight assessed through ultrasound using the Brazilian fetal weight chart for gestational age was the gold standard. A subsample of 122 women with neonatal weight measurements was taken up to seven days after estimated fetal weight measurements and symphisys-fundal classification was compared with Lubchenco growth reference curve as gold standard. Sensitivity, specificity, positive and negative predictive values were calculated. The McNemar χ2 test was used for comparing sensitivity of both symphisys-fundal curves studied. RESULTS: The sensitivity of the new curve for detecting small for gestational age fetuses was 51.6% while that of the Brazilian Ministry of Health reference curve was significantly lower (12.5%. In the subsample using neonatal weight as gold standard, the sensitivity of the new reference curve was 85.7% while that of the Brazilian Ministry of Health was 42.9% for detecting small for gestational age. CONCLUSIONS: The diagnostic performance of the new curve for detecting small for gestational age fetuses was significantly higher than that of the Brazilian Ministry of Health reference curve.

  13. Dynamic response of HTS composite tapes to pulsed currents

    International Nuclear Information System (INIS)

    Meerovich, V; Sokolovsky, V; Prigozhin, L; Rozman, D

    2006-01-01

    Dynamic voltage-current characteristics of an HTS Ag/BiSCCO composite tape are studied both experimentally and theoretically. The tape is subjected to pulsed currents with different shapes and magnitudes and voltage traces are measured using the four-point method with different locations of potential taps on the sample surface. Clockwise and anticlockwise hysteresis loops are obtained for the same sample depending on the location of the potential taps. The dynamic characteristics deviate substantially from the DC characteristic, especially in the range of low voltages where a criterion for the critical current value is usually chosen (1-10 μV cm -1 ). The critical current determined from dynamic characteristics and its change with the pulse magnitude depend on the location of the potential taps and on the curve branch chosen for the critical current determination (ascending or descending). The theoretical analysis is based on a model of the magnetic flux diffusion into a composite tape for a superconductor described by the flux creep characteristic. Numerical simulation based on this model gives results in good agreement with the experimental ones and explains the observed peculiarities of the dynamic characteristics of HTS composite tapes. The difference between the magnetic diffusion into a tape and a slab is discussed

  14. Reliability of the xipho-pubic angle in patients with sagittal imbalance of the spine.

    Science.gov (United States)

    Langella, Francesco; Villafañe, Jorge H; Ismael, Maryem; Buric, Josip; Piazzola, Andrea; Lamartina, Claudio; Berjano, Pedro

    2018-04-01

    Proximal junctional kyphosis (PJK) is a frequent complication that compromises the outcomes of spinal surgery, especially for adult deformity. To the date no single risk factor or cause has been identified that explains its occurrence. The purpose of this study was to investigate the test-retest reliability of the radiologic measurements using xipho-pubic angle (XPA) for subjects undergoing surgery for sagittal misalignment of the spine. Retrospective observational cross-sectional study of prospectively collected data. Full-spine standing lateral radiographs of 50 patients who underwent surgery for fixed sagittal imbalance (preoperative and postoperative) were evaluated. Internal consistency, reproducibility, concurrent validity, and discriminative ability of the XPA. Two physicians measured XPA on the 100 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), were calculated for inter and intraobserver agreement. Test-retest reliability of XPA measurement was excellent for pre- (ICC=0.98; P=0.001) and post-surgical (ICC=0.86; P=0.001) radiographs of subjects with sagittal imbalance of the spine. XPA was able to discriminate between preoperative and postoperative radiographs F=17.924, Pimbalance for both raters. There were significant differences between pre- vs. postoperative XPA, pelvic tilt, lumbar lordosis and sagittal vertical axis values (all Pimbalance.

  15. Relationship between thoracic hypokyphosis, lumbar lordosis and sagittal pelvic parameters in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Clément, Jean-Luc; Geoffray, Anne; Yagoubi, Fatima; Chau, Edouard; Solla, Federico; Oborocianu, Ioana; Rampal, Virginie

    2013-11-01

    Sagittal spine and pelvic alignment of adolescent idiopathic scoliosis (AIS) is poorly described in the literature. It generally reports the sagittal alignment with regard to the type of curve and never correlated to the thoracic kyphosis. The objective of this study is to investigate the relationship between thoracic kyphosis, lumbar lordosis and sagittal pelvic parameters in thoracic AIS. Spinal and pelvic sagittal parameters were evaluated on lateral radiographs of 86 patients with thoracic AIS; patients were separated into hypokyphosis group (n = 42) and normokyphosis group (n = 44). Results were statistically analyzed. The lumbar lordosis was lower in the hypokyphosis group, due to the low proximal lordosis. The thoracic kyphosis was not correlated with any pelvic parameters but with the proximal lordosis. The pelvic incidence was correlated with sacral slope, pelvic tilt, lumbar lordosis and highly correlated with distal lumbar lordosis in the two groups. There was a significant linear regression between thoracic kyphosis and proximal lordosis and between pelvic incidence and distal lordosis. We can consider that the proximal part of the lordosis depends on the thoracic kyphosis and the distal part depends on the pelvic incidence. The hypokyphosis in AIS is independent of the pelvic parameters and could be described as a structural parameter, characteristic of the scoliotic deformity.

  16. ANKLE TAPING DOES NOT IMPAIR PERFORMANCE IN JUMP OR BALANCE TESTS

    Directory of Open Access Journals (Sweden)

    Javier Abián-Vicén

    2008-09-01

    Full Text Available This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96. The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed

  17. Study on influence of irradiation vulcanization to silicon rubber autohesive tape's properties

    International Nuclear Information System (INIS)

    Chen Chun; Tang Jian; Wu Ling; Han Yingchun; Zhou Hong; Mo Yan; Fu Haijun

    2006-01-01

    After using 60 Co γ-ray to irradiate vulcanization silicon rubber autohesive tape, the effect of absorbed dose to the autohesive tape's tensile strength, elongation at break, autohesion and breakdown voltage strength and dose rate's effect to the autohesive tape's properties were studied. The results indicate that autohesive tape's tensile strength increases and the elongation at break decreases with the increasing dose. Under the dose of 25 kGy, the tape's autohesion increases with the increasing dose. When the dose is up to 25 kGy, the tape's autohesion achieves to the maximum, and then decreases with the increasing dose. Absorbed dose has no effect to the tape's breakdown voltage strength, and the dose rate has no effect to the autohesive tape's properties. (authors)

  18. Kinesio Taping to generate skin convolutions is not better than sham taping for people with chronic non-specific low back pain: a randomised trial

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-06-01

    Full Text Available Question: For people with chronic low back pain, does Kinesio Taping, applied according to the treatment manual to create skin convolutions, reduce pain and disability more than a simple application without convolutions? Design: Randomised trial with concealed allocation, intention-to-treat analysis and blinded assessment of some outcomes. Participants: 148 participants with chronic non-specific low back pain. Intervention: Experimental group participants received eight sessions (over four weeks of Kinesio Taping applied according to the Kinesio Taping Method treatment manual (ie, 10 to 15% tension applied in flexion to create skin convolutions in neutral. Control group participants received eight sessions (over four weeks of Kinesio Taping with no tension, creating no convolutions. Outcome measures: The primary outcome measures were pain intensity and disability after the four-week intervention. Secondary outcomes were pain intensity and disability 12 weeks after randomisation, and global perceived effect at both four and 12 weeks after randomisation. Results: Applying Kinesio Tape to create convolutions in the skin did not significantly change its effect on pain (MD–0.4 points, 95% CI–1.3 to 0.4 or disability (MD–0.3 points, 95% CI–1.9 to 1.3 at four weeks. There was a small difference in favour of the experimental group for the secondary outcome of global perceived effect (MD 1.4 points, 95% CI 0.3 to 2.5 at four weeks. No significant between-group differences were observed for the other secondary outcomes. Conclusion: Kinesio Taping applied with stretch to generate convolutions in the skin was no more effective than simple application of the tape without tension for the outcomes measured. These results challenge the proposed mechanism of action of this therapy. Trial registration: Brazilian Registry of Clinical Trials, RBR-7ggfkv. [Parreira PCS, Costa LCM, Takahashi R, Hespanhol Junior LC, da Luz Junior MA, da Silva TM, Costa LOP

  19. CLEARANCE OF ARCHIVE TAPE VAULT (BUILDING 186)

    CERN Multimedia

    EP Division

    1999-01-01

    The archive tape vault is being cleared to make way for the LHC experiments silicon facility.Experiments were contacted in February to arrange for the extended storage or destruction of archived volumes. Any who have not yet done so are asked to contactR. Minchin/IT immediately.This is also an opportunity to clear unused tapes or cartridges from around the site and have them destroyed ecologically. Please contact ep.smi.helpdesk@cern.ch to arrange for collection.A.E. Ball/EP-SMI

  20. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  1. Extensor Tendon Instability Due to Sagittal Band Injury in a Martial Arts Athlete: A Case Report.

    Science.gov (United States)

    Kochevar, Andrew; Rayan, Ghazi

    2017-03-01

    A Taekwondo participant sustained a hand injury from punching an opponent that resulted in painful instability of the ring finger extensor digitorum communis tendon due to sagittal band damage. His symptoms resolved after reconstructive surgery on the sagittal band (SB) with stabilization of the extensor tendon over the metacarpophalangeal joint.

  2. Anterior sagittal transanorectal approach to the posterior urethra in the pediatric age group.

    Science.gov (United States)

    Rossi, F; De Castro, R; Ceccarelli, P L; Dòmini, R

    1998-09-01

    Surgical access to the posterior urethra is often difficult and several surgical solutions have been proposed. We suggest an anterior sagittal transanorectal approach based on splitting the anterior rectal wall only. This alternative technique provides excellent exposure to the retrourethral region, permitting simple and safe surgery. Between 1994 and 1996 we performed surgery via the anterior sagittal transanorectal approach in 8 patients with a mean age of 9.06 years. Patients included 1 girl with a posttraumatic urethrovaginal fistula, 3 with intersex disorders (2 with mixed gonadal dysgenesis raised as boys and 1 with male dysgenetic pseudohermaphroditism with an enlarged urtricle) and 4 boys (1 with penile agenesis raised as girl, 2 with urethral duplication and 1 with prostatic rhabdomyosarcoma). The patient was placed in a knee-chest position. A midline sagittal incision was made through the anterior anorectal wall only and deepened through the perineal body to expose the posterior urethra and retrovesical space. After the pathological condition was corrected the anterior rectal wall and perineal body were reconstructed. The operation was completed with protective colostomy. In our final patient with prostatic rhabdomyosarcoma the anterior sagittal transanorectal approach was used without colostomy. Anorectal manometry was done 6 months postoperatively. All patients were completely continent of stool and urine. Convalescence was unremarkable in all cases. Postoperative manometry in 7 patients revealed no differences from preoperative measurements. This procedure should be considered a useful alternative to other techniques for various congenital and acquired pelvic disorders.

  3. Mirror-Touch and Ticker Tape Perceptions in Synesthesia

    Directory of Open Access Journals (Sweden)

    Charlotte Anne Chun

    2013-11-01

    Full Text Available A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia’s connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person’s arm being stroked can evoke physical touch sensation on one’s own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker’s mouth. To explore synesthesia’s associations with these phenomena, a diverse group (n=3,743 was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1,017 eligible respondents, synesthetes (across all subtypes reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However effect size was small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2 to 4% and sequence-space synesthesia (9 to 14%. Within synesthesia, grapheme-personification, also called ordinal-linguistic personification was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect

  4. String and Sticky Tape Experiments.

    Science.gov (United States)

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  5. Impact of sagittal spinopelvic alignment on clinical outcomes after decompression surgery for lumbar spinal canal stenosis without coronal imbalance.

    Science.gov (United States)

    Hikata, Tomohiro; Watanabe, Kota; Fujita, Nobuyuki; Iwanami, Akio; Hosogane, Naobumi; Ishii, Ken; Nakamura, Masaya; Toyama, Yoshiaki; Matsumoto, Morio

    2015-10-01

    The object of this study was to investigate correlations between sagittal spinopelvic alignment and improvements in clinical and quality-of-life (QOL) outcomes after lumbar decompression surgery for lumbar spinal canal stenosis (LCS) without coronal imbalance. The authors retrospectively reviewed data from consecutive patients treated for LCS with decompression surgery in the period from 2009 through 2011. They examined correlations between preoperative or postoperative sagittal vertical axis (SVA) and radiological parameters, clinical outcomes, and health-related (HR)QOL scores in patients divided according to SVA. Clinical outcomes were assessed according to Japanese Orthopaedic Association (JOA) and visual analog scale (VAS) scores. Health-related QOL was evaluated using the Roland-Morris Disability Questionnaire (RMDQ) and the JOA Back Pain Evaluation Questionnaire (JOABPEQ). One hundred nine patients were eligible for inclusion in the study. Compared to patients with normal sagittal alignment prior to surgery (Group A: SVA imbalance (Group B: SVA ≥ 50 mm) had significantly smaller lumbar lordosis and thoracic kyphosis angles and larger pelvic tilt. In Group B, there was a significant decrease in postoperative SVA compared with the preoperative SVA (76.3 ± 29.7 mm vs. 54.3 ± 39.8 mm, p = 0.004). The patients in Group B with severe preoperative sagittal imbalance (SVA > 80 mm) had residual sagittal imbalance after surgery (82.8 ± 41.6 mm). There were no significant differences in clinical and HRQOL outcomes between Groups A and B. Compared to patients with normal postoperative SVA (Group C: SVA imbalance. Decompression surgery improved the SVA value in patients with preoperative sagittal imbalance; however, the patients with severe preoperative sagittal imbalance (SVA > 80 mm) had residual imbalance after decompression surgery. Both clinical and HRQOL outcomes were negatively affected by postoperative residual sagittal imbalance.

  6. On the weld strength of in situ tape placed reinforcements on weave reinforced structures

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, Bert; Akkerman, Remko

    2012-01-01

    Unidirectionally reinforced thermoplastic tapes were welded onto woven fabric reinforced laminates using a laser assisted tape placement process. A mandrel peel setup was used to quantify the interfacial fracture toughness between the tape and the laminate as a measure for weld strength. The tape

  7. Alphabet Soup: Sagittal Balance Correction Osteotomies of the Spine-What Radiologists Should Know.

    Science.gov (United States)

    Takahashi, T; Kainth, D; Marette, S; Polly, D

    2018-04-01

    Global sagittal malalignment has been demonstrated to have correlation with clinical symptoms and is a key component to be restored in adult spinal deformity. In this article, various types of sagittal balance-correction osteotomies are reviewed primarily on the basis of the 3 most commonly used procedures: Smith-Petersen osteotomy, pedicle subtraction osteotomy, and vertebral column resection. Familiarity with the expected imaging appearance and commonly encountered complications seen on postoperative imaging studies following correction osteotomies is crucial for accurate image interpretation. © 2018 by American Journal of Neuroradiology.

  8. Evaluation of uterine peristalsis using cine MRI on the coronal plane in comparison with the sagittal plane.

    Science.gov (United States)

    Shitano, Fuki; Kido, Aki; Kataoka, Masako; Fujimoto, Koji; Kiguchi, Kayo; Fushimi, Yasutaka; Togashi, Kaori

    2016-01-01

    Uterine peristalsis is supposed to be closely related to the early stages of reproduction. Sperms are preferentially transported from the uterine cervix to the side of the tube with the dominant follicle. However, with respect to magnetic resonance imaging (MRI), uterine peristalsis has only been evaluated at the sagittal plane of cine MRI. To evaluate and compare uterine peristalsis both on sagittal and coronal planes using cine MRI. Internal ethics committee approval was obtained, and subjects provided informed written consent. Thirty-one women underwent MRI scans in the periovulatory phase of the menstrual cycle. Cine MR images obtained by fast advanced spin echo sequence at 3-T field strength magnet (Toshiba Medical Systems) were visually evaluated by two independent radiologists. The frequency and the direction of peristalsis, and the presence of outer myometrium conduction of signal intensities (OMC), were evaluated. The laterality of the dominant follicle was determined on axial images and compared with the peristaltic direction in fundus. The subjects in which peristaltic directions were more clearly recognized were significantly frequent in coronal planes than in sagittal planes (P < 0.05). There was no significant difference in the peristaltic frequency between the sagittal and the coronal plane. However, the OMC was more recognized in the coronal plane than in the sagittal plane (P < 0.05). Peristaltic waves conducted toward the possible ovulation side were observed in only three of the 10 subjects. OMC of uterine peristalsis was better demonstrated in the coronal plane compared to the sagittal plane. © The Foundation Acta Radiologica 2015.

  9. VHS-tape system for general purpose computer. For next generation mass storage system

    International Nuclear Information System (INIS)

    Ukai, K.; Takano, M.; Shinohara, M.; Niki, K.; Suzuki, Y.; Hamada, T.; Ogawa, M.

    1994-07-01

    Mass storage is one of the key technology of next generation computer system. A huge amount of data is produced on a field of particle and nuclear physics. These data are raw data of experiments, analysis data, Monte Carlo simulations data, etc. We search a storage device for these data at the point of view of capacity, price, size, transfer speed, etc. We have selected a VHS-tape (12.7 mm-tape, helical scan) from many storage devices. Characteristics of the VHS-tape are as follows; capacity of 14.5 GB, size of 460 cm 3 , price of 1,000 yen (S-VHS tape for video use), and 1.996 MB/sec transfer speed at a sustained mode. Last year, we succeeded to operate the VHS-tape system on a workstation as a I/O device with read/write speed of 1.5 MB/sec. We have tested a VHS-tape system by connecting to the channel of the general purpose computer (Fujitsu M-780/10S) in our institute. We obtained a read and write speeds of 1.07 MB/sec and 1.72 MB/sec by FORTRAN test programs, respectively. Read speeds of an open reel tape and a 3480 type cassete tape by the same test programs are 1.13 MB/sec and 2.54 MB/sec, respectively. Speeds of write operation are 1.09 MB/sec and 2.54 MB/sec for the open reel and 3480 cassete tape, respectively. A start motion of the VHS-tape for read/write operations needs about 60 seconds. (author)

  10. Torsional Properties of TiNi Shape Memory Alloy Tape for Rotary Actuator

    Science.gov (United States)

    Takeda, K.; Tobushi, H.; Mitsui, K.; Nishimura, Y.; Miyamoto, K.

    2012-12-01

    In order to develop novel shape memory actuators, the torsional deformation of a shape memory alloy (SMA) tape and the actuator models driven by the tape were investigated. The results obtained can be summarized as follows. In the SMA tape subjected to torsion, the martensitic transformation appears along both edges of the tape due to elongation of these elements and grows to the central part. The fatigue life in both the pulsating torsion and alternating torsion is expressed by the unified relationship of the dissipated work in each cycle. Based on an opening and closing door model and a solar-powered active blind model, the two-way rotary driving actuator with a small and simple mechanism can be developed by using torsion of the SMA tape.

  11. Gender difference of ankle stability in the sagittal and frontal planes.

    Science.gov (United States)

    Hanzlick, Harrison; Hyunglae Lee

    2017-07-01

    This paper offers quantification of ankle stability in relation to simulated haptic environments of varying stiffness. This study analyzes the stability trends of male and female subjects independently over a wide range of simulated environments after subjects were exposed to vigorous position perturbation. Ankle stability was quantified for both degrees-of-freedom of the ankle in the sagittal and frontal planes. Subjects' stability consistently decreased when exposed to environments of negative simulated stiffness. In the frontal plane, male and female subjects exhibited nearly identical stability levels. In the sagittal plane, however, male subjects demonstrated marginally more stability than female subjects in environments with negative stiffness. Results of this study are beneficial to understanding situations in which the ankle is likely to lose stability, potentially resulting in injury.

  12. Does Kinesiology tape counter exercise-related impairments of balance in the elderly?

    Science.gov (United States)

    Hosp, Simona; Csapo, Robert; Heinrich, Dieter; Hasler, Michael; Nachbauer, Werner

    2018-05-01

    Maintaining balance is an essential requirement for the performance of daily tasks and sporting activities, particularly in older adults to prevent falls and associated injuries. Kinesiology tape has gained great popularity in sports and is frequently used as a tool for performance enhancement. However, there is little research investigating its influence on balance. The purpose of this study was to evaluate the effect of Kinesiology tape on dynamic balance, postural stability and knee proprioception after physical activity in healthy, older adults. Twelve physically active, healthy men aged 63-77 years performed the test on two separate days, with and without Kinesiology tape at the knee joint (prospective intervention with cross-over design). Dynamic balance during an obstacle-crossing task, postural stability in a single-leg stance test, and knee joint position sense as a measure of proprioception were examined before and after 30 min of downhill walking on a treadmill. The influences of taping condition and physical activity on all parameters were statistically tested using factorial ANOVAs. Factorial ANOVA revealed significant time × taping condition interaction effects on all performance parameters (p postural stability and knee proprioception differed between the two taping conditions. The deterioration of performance was always greater when no tape was used. This study demonstrated that physical exercise significantly deteriorated dynamic balance, postural stability and knee proprioception in older men. These effects can be attenuated through the usage of Kinesiology tape. By preventing exercise-related impairments of balance, Kinesiology tape might help reduce the risk of sports-associated falls and associated injuries. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    Science.gov (United States)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  14. A software package to process an INIS magnetic tape on the VAX computer

    International Nuclear Information System (INIS)

    Omar, A.A.; Mohamed, F.A.

    1991-01-01

    This paper presents a software package whose function is to process the magnetic tapes distributed by the Atomic Energy Agency, on the VAX computers. These tapes contain abstracts of papers in the different branches of nuclear field and is supplied from the international Nuclear Information system (INIS). Two goals are aimed from this paper. First it gives a procedure to process any foreign magnetic tape on the VAX computers. Second, it solves the problem of reading the INIS tapes on a non IBM computer and thus allowing the specialists to gain from the large amount of information contained in these tapes. 11 fig

  15. Texture gradients in Fe-sheathed ex situ produced MgB2 tapes

    International Nuclear Information System (INIS)

    Lezza, P; Gladyshevskii, R; Abaecherli, V; Fluekiger, R

    2006-01-01

    Superconducting Fe-sheathed MgB 2 monofilamentary tapes have been fabricated by the powder-in-tube technique, varying the particle size of the starting MgB 2 powder and applying either cold or hot rolling during the last deformation process. Measurements of the critical current density J c with the magnetic field applied parallel or perpendicular to the tape surface revealed a pronounced anisotropy for the cold rolled tapes, which was found to increase with increasing particle size and magnetic field strength. The microstructural origin of the J c anisotropy was confirmed by means of x-ray diffraction performed on the filaments after mechanical removal of the sheath. The local texture was studied in a series of diffraction patterns collected at different distances from the filament centre, removing each time some 25 μm of the filament thickness. In the cold rolled tapes, the average orientation of the MgB 2 grains was found to approach a preferred orientation with the crystallographic c-axis perpendicular to the tape surface, near the interface with the sheath; however, the misalignment angle increased towards the centre of the tape. In the hot rolled tapes, for which no J c anisotropy was observed, the grains were found to be approximately randomly oriented. Roughness measurements performed on the side of the Fe sheath in contact with the MgB 2 filament are in agreement with the difference in texture observed for cold and hot rolled tapes

  16. Tape cast isotropic, fine-grained tungsten for thermo-cyclic loading applications

    Energy Technology Data Exchange (ETDEWEB)

    Sommerer, Mathias, E-mail: Mathias.Sommerer@tum.de [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); Li, Muyuan [Max-Planck-Institut für Plasma Physik, Boltzmannstraße 2, 85748 Garching (Germany); Werner, Ewald [Lehrstuhl für Werkstoffkunde und Werkstoffmechanik, Technische Universität München, Boltzmannstr. 15, 85748 Garching (Germany); Dewitz, Hubertus von; Walter, Steffen; Lampenscherf, Stefan [Siemens AG, Corporate Technology, Otto-Hahn-Ring 6, 81730 München (Germany); Arnold, Thomas [Siemens Healthcare GmbH, Henkestr. 127, 91052 Erlangen (Germany)

    2016-04-15

    Highlights: • The tape casting process for tungsten is described. • A set-up of a HHF test facility for standing anodes is presented. • The thermo-cyclic behavior of tape cast tungsten and a reference is investigated. • The evolution of crack patterns is described in dependency of HHF-loadings. • The surface roughness of X-ray anodes is related to the microstructural evolution. - Abstract: This paper introduces tape casting as a new route for the production of isotropic and fine-grained tungsten components. Microstructural and thermal properties of tape cast tungsten samples are determined. Thermal shock behavior according to the thermo-cyclic loading of standing X-ray anodes is investigated and compared to the behavior of a rolled tungsten grade. The development of surface roughness during the thermal shock loading is discussed in relation to the development of the grain structure and crack pattern. The fine-grained and stable microstructure of the tape cast material exhibits less roughening under such test conditions.

  17. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    Science.gov (United States)

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  18. Modelling of Tape Casting for Ceramic Applications

    DEFF Research Database (Denmark)

    Jabbari, Masoud

    was increased by improving the steady state model with a quasi-steady state analytical model. In order to control the most important process parameter, tape thickness, the two-doctor blade configuration was also modeled analytically. The model was developed to control the tape thickness based on the machine...... for magnetic refrigeration applications. Numerical models were developed to track the migration of the particles inside the ceramic slurry. The results showed the presence of some areas inside the ceramic in which the concentration of the particles is higher compared to other parts, creating the resulting...

  19. Video raster stereography back shape reconstruction: a reliability study for sagittal, frontal, and transversal plane parameters.

    Science.gov (United States)

    Schroeder, J; Reer, R; Braumann, K M

    2015-02-01

    As reliability of raster stereography was proved only for sagittal plane parameters with repeated measures on the same day, the present study was aiming at investigating variability and reliability of back shape reconstruction for all dimensions (sagittal, frontal, transversal) and for different intervals. For a sample of 20 healthy volunteers, intra-individual variability (SEM and CV%) and reliability (ICC ± 95% CI) were proved for sagittal (thoracic kyphosis, lumbar lordosis, pelvis tilt angle, and trunk inclination), frontal (pelvis torsion, pelvis and trunk imbalance, vertebral side deviation, and scoliosis angle), transversal (vertebral rotation), and functional (hyperextension) spine shape reconstruction parameters for different test-retest intervals (on the same day, between-day, between-week) by means of video raster stereography. Reliability was high for the sagittal plane (pelvis tilt, kyphosis and lordosis angle, and trunk inclination: ICC > 0.90), and good to high for lumbar mobility (0.86 < ICC < 0.97). Apart from sagittal plane spinal alignment, there was a lack of certainty for a high reproducibility indicated by wider ICC confidence intervals. So, reliability was fair to high for vertebral side deviation and the scoliosis angle (0.71 < ICC < 0.95), and poor to good for vertebral rotation values as well as for frontal plane upper body and pelvis position parameters (0.65 < ICC < 0.92). Coefficients for the between-day and between-week interval were a little lower than for repeated measures on the same day. Variability (SEM) was less than 1.5° or 1.5 mm, except for trunk inclination. Relative variability (CV) was greater in global trunk position and pelvis parameters (35-98%) than in scoliosis (14-20%) or sagittal sway parameters (4-8 %). Although we found a lower reproducibility for the frontal plane, raster stereography is considered to be a reliable method for the non-invasive, three-dimensional assessment of spinal alignment in normal non

  20. Transaction aware tape-infrastructure monitoring

    International Nuclear Information System (INIS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-01-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  1. Postural Consequences of Cervical Sagittal Imbalance: A Novel Laboratory Model.

    Science.gov (United States)

    Patwardhan, Avinash G; Havey, Robert M; Khayatzadeh, Saeed; Muriuki, Muturi G; Voronov, Leonard I; Carandang, Gerard; Nguyen, Ngoc-Lam; Ghanayem, Alexander J; Schuit, Dale; Patel, Alpesh A; Smith, Zachary A; Sears, William

    2015-06-01

    A biomechanical study using human spine specimens. To study postural compensations in lordosis angles that are necessary to maintain horizontal gaze in the presence of forward head posture and increasing T1 sagittal tilt. Forward head posture relative to the shoulders, assessed radiographically using the horizontal offset distance between the C2 and C7 vertebral bodies (C2-C7 [sagittal vertical alignment] SVA), is a measure of global cervical imbalance. This may result from kyphotic alignment of cervical segments, muscle imbalance, as well as malalignment of thoracolumbar spine. Ten cadaveric cervical spines (occiput-T1) were tested. The T1 vertebra was anchored to a tilting and translating base. The occiput was free to move vertically but its angular orientation was constrained to ensure horizontal gaze regardless of sagittal imbalance. A 5-kg mass was attached to the occiput to mimic head weight. Forward head posture magnitude and T1 tilt were varied and motions of individual vertebrae were measured to calculate C2-C7 SVA and lordosis across C0-C2 and C2-C7. Increasing C2-C7 SVA caused flexion of lower cervical (C2-C7) segments and hyperextension of suboccipital (C0-C1-C2) segments to maintain horizontal gaze. Increasing kyphotic T1 tilt primarily increased lordosis across the C2-C7 segments. Regression models were developed to predict the compensatory C0-C2 and C2-C7 angulation needed to maintain horizontal gaze given values of C2-C7 SVA and T1 tilt. This study established predictive relationships between radiographical measures of forward head posture, T1 tilt, and postural compensations in the cervical lordosis angles needed to maintain horizontal gaze. The laboratory model predicted that normalization of C2-C7 SVA will reduce suboccipital (C0-C2) hyperextension, whereas T1 tilt reduction will reduce the hyperextension in the C2-C7 segments. The predictive relationships may help in planning corrective strategy in patients experiencing neck pain, which may be

  2. A morphological description of the sagittal otoliths of two mormyrids ...

    African Journals Online (AJOL)

    The morphology of the sagittal otoliths of two South African mormyrid fish, Marcusenius macrolepidotus and Petrocephalus catostoma, were studied to determine possible morphological significance. The sagittae of M. macrolepidotus and P. catostoma are kidney-shaped and oblong, respectively. The ventral margin is ...

  3. Modelling and measurement of ac loss in BSCCO/Ag-tape windings

    International Nuclear Information System (INIS)

    Oomen, M P; Nanke, R; Leghissa, M

    2003-01-01

    High-temperature superconducting (HTS) transformers promise decreased weight and volume and higher efficiency. A 1 MVA HTS railway transformer was built and tested at Siemens AG. This paper deals with the prediction of ac loss in the BSCCO/Ag-tape windings. In a railway transformer the tape carries ac current in alternating field, the temperature differs from 77 K, tapes are stacked or cabled and overcurrents and higher harmonics occur. In ac-loss literature these issues are treated separately, if at all. We have developed a model that predicts the ac loss in sets of BSCCO/Ag-tape coils, and deals with the above-mentioned issues. The effect of higher harmonics on the loss in HTS tapes is considered for the first time. The paper gives a complete overview of the model equations and required input parameters. The model is validated over a wide range of the input parameters, using the measured critical current and ac loss of single tapes, single coils and sets of coils in the 1 MVA transformer. An accuracy of around 25% is achieved in all relevant cases. Presently the model is developed further, in order to describe other HTS materials and other types of applications

  4. Sagittal balance, a useful tool for neurosurgeons?

    Science.gov (United States)

    Villard, Jimmy; Ringel, Florian; Meyer, Bernhard

    2014-01-01

    New instrumentation techniques have made any correction of the spinal architecture possible. Sagittal balance has been described as an important parameter for assessing spinal deformity in the early 1970s, but over the last decade its importance has grown with the published results in terms of overall quality of life and fusion rate. Up until now, most of the studies have concentrated on spinal deformity surgery, but its use in the daily neurosurgery practice remains uncertain and may warrant further studies.

  5. Degradation characteristics of 2G HTS tapes with respect to an electrical breakdown

    International Nuclear Information System (INIS)

    Kang, Jong O; Lee, On You; Mo, Young Kyu; Kim, Jun Il; Bang, Seung Min; Lee, Hong Seok; Kang, Hyoung Ku; Lee, Jae Hun; Jang, Cheol Yeong

    2015-01-01

    The electrical insulation design for a superconducting coil system is important for developing high voltage superconducting apparatuses. Also, the degraded characteristics of superconducting tapes due to an electrical breakdown should be considered for superconducting coils design. In this study, the degradation characteristics of 2G high temperature superconducting (HTS) tapes were studied with respect to electrical breakdown tests. The degradation tests of 2G HTS tapes were performed with various stabilizer materials. The degradation characteristics of 2G HTS tapes such as critical current(Ic) and index number were observed by performing electrical breakdown tests. It was found that the characteristics such as Ic and index number can be degraded by an electrical breakdown. Moreover, it was concluded that the degradation characteristics of 2G HTS tapes were affected by a stabilizer material and applied breakdown voltage. The cross sectional view of 2G HTS tapes was observed by using a scanning electron microscope (SEM). As results, it is found that the degradation characteristics of 2G HTS tapes are concerned with hardness and electrical resistivity of stabilizer layers

  6. The Role of Proprioception in the Sagittal Setting of Anticipatory Postural Adjustments During Gait Initiation

    OpenAIRE

    Pereira Marcelo P.; Pelicioni Paulo H. Silva; Gobbi Lilian T.B.

    2015-01-01

    Purpose. Previous studies have studied the role of proprioception on the setting of anticipatory postural adjustments (APA) during gait initiation. However, these studies did not investigate the role of proprioception in the sagittal APA setting. We aimed to investigate the role of proprioception manipulation to induce APA sagittal adaptations on gait initiation. Methods. Fourteen healthy adults performed gait initiation without, and with, vibration applied before movement onset, and during m...

  7. Usefulness of the dynamic gadolinium-enhanced magnetic resonance imaging with simultaneous acquisition of coronal and sagittal planes for detection of pituitary microadenomas.

    Science.gov (United States)

    Lee, Han Bee; Kim, Sung Tae; Kim, Hyung-Jin; Kim, Keon Ha; Jeon, Pyoung; Byun, Hong Sik; Choi, Jin Wook

    2012-03-01

    Does dynamic gadolinium-enhanced imaging with simultaneous acquisition of coronal and sagittal planes improve diagnostic accuracy of pituitary microadenomas compared with coronal images alone? Fifty-six patients underwent 3-T sella MRI including dynamic simultaneous acquisition of coronal and sagittal planes after gadolinium injection. According to conspicuity, lesions were divided into four scores (0, no; 1, possible; 2, probable; 3, definite delayed enhancing lesion). Additional information on supplementary sagittal images compared with coronal ones was evaluated with a 4-point score (0, no; 1, possible; 2, probable; 3, definite additional information). Accuracy of tumour detection was calculated. Average scores for lesion detection of a combination of two planes, coronal, and sagittal images were 2.59, 2.32, and 2.18. 6/10 lesions negative on coronal images were detected on sagittal ones. Accuracy of a combination of two planes, of coronal and of sagittal images was 92.86%, 82.14% and 75%. Six patients had probable or definite additional information on supplementary sagittal images compared with coronal ones alone (10.71%). Dynamic MRI with combined coronal and sagittal planes was more accurate for detection of pituitary microadenomas than routinely used coronal images. Simultaneous dynamic enhanced acquisition can make study time fast and costs low. We present a new dynamic MRI technique for evaluating pituitary microadenomas • This technique provides simultaneous acquisition of contrast enhanced coronal and sagittal images. • This technique makes the diagnosis more accurate and reduces the examination time. • Such MR imaging only requires one single bolus of contrast agent.

  8. Electrical and mechanical properties of Bi-2223/Ag/barrier/Ag composite tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Goemoery, F.; Oduleye, O.O.; Alford, N.McN.; Pachla, W.; Diduszko, R.

    2000-01-01

    Bi-2223/Ag/barrier/Ag single-core tapes with various oxide barrier materials (BaZrO 3 , SrCO 3 , ZrO 2 and Al 2 O 3 ) have been prepared by PIT. The I-V curves and ac susceptibility measurements have been performed for tapes with identical heat treatment history. Young's moduli of these tape samples have been evaluated by three-point bending and the structure of barrier powders and BSCCO cores was analysed by SEM and XRD, respectively. It was found that the shape of I-V curves, the current transfer lengths and the mechanical properties of tapes are all affected by the oxide barrier type and the barrier thickness, as well as by its porosity and uniformity. This is because the oxide barrier controls the oxygen diffusion during the tape heat treatment and simultaneously the HTS phase formation kinetics, its purity and content within the superconducting core. On the base of the results obtained for single-core tapes, two kinds of multifilamentary composite were made and tested. (author)

  9. Tape measure to aid prescription in paediatric resuscitation.

    OpenAIRE

    Hughes, G; Spoudeas, H; Kovar, I Z; Millington, H T

    1990-01-01

    A tape measure, based on 50th centile weight for height and designed to permit easy drug dosage calculation, endotracheal tube size and DC cardioversion current dosages in childrens' emergencies, was tested for reliability by medical and nursing staff with varying paediatric experience. We found that the tape measure gave a reproducible estimate of weight and suggest that its use would facilitate decision making by inexperienced medical and nursing staff in paediatric resuscitation when there...

  10. Research on resistance characteristics of YBCO tape under short-time DC large current impact

    Science.gov (United States)

    Zhang, Zhifeng; Yang, Jiabin; Qiu, Qingquan; Zhang, Guomin; Lin, Liangzhen

    2017-06-01

    Research of the resistance characteristics of YBCO tape under short-time DC large current impact is the foundation of the developing DC superconducting fault current limiter (SFCL) for voltage source converter-based high voltage direct current system (VSC-HVDC), which is one of the valid approaches to solve the problems of renewable energy integration. SFCL can limit DC short-circuit and enhance the interrupting capabilities of DC circuit breakers. In this paper, under short-time DC large current impacts, the resistance features of naked tape of YBCO tape are studied to find the resistance - temperature change rule and the maximum impact current. The influence of insulation for the resistance - temperature characteristics of YBCO tape is studied by comparison tests with naked tape and insulating tape in 77 K. The influence of operating temperature on the tape is also studied under subcooled liquid nitrogen condition. For the current impact security of YBCO tape, the critical current degradation and top temperature are analyzed and worked as judgment standards. The testing results is helpful for in developing SFCL in VSC-HVDC.

  11. Three-dimensional finite element models of the human pubic symphysis with viscohyperelastic soft tissues.

    Science.gov (United States)

    Li, Zuoping; Alonso, Jorge E; Kim, Jong-Eun; Davidson, James S; Etheridge, Brandon S; Eberhardt, Alan W

    2006-09-01

    Three-dimensional finite element (FE) models of human pubic symphyses were constructed from computed tomography image data of one male and one female cadaver pelvis. The pubic bones, interpubic fibrocartilaginous disc and four pubic ligaments were segmented semi-automatically and meshed with hexahedral elements using automatic mesh generation schemes. A two-term viscoelastic Prony series, determined by curve fitting results of compressive creep experiments, was used to model the rate-dependent effects of the interpubic disc and the pubic ligaments. Three-parameter Mooney-Rivlin material coefficients were calculated for the discs using a heuristic FE approach based on average experimental joint compression data. Similarly, a transversely isotropic hyperelastic material model was applied to the ligaments to capture average tensile responses. Linear elastic isotropic properties were assigned to bone. The applicability of the resulting models was tested in bending simulations in four directions and in tensile tests of varying load rates. The model-predicted results correlated reasonably with the joint bending stiffnesses and rate-dependent tensile responses measured in experiments, supporting the validity of the estimated material coefficients and overall modeling approach. This study represents an important and necessary step in the eventual development of biofidelic pelvis models to investigate symphysis response under high-energy impact conditions, such as motor vehicle collisions.

  12. Body posture in the sagittal plane and scoliotic variables in girls aged 7-18

    Directory of Open Access Journals (Sweden)

    Jacek Wilczyński

    2018-02-01

    Introduction. The aim of the study was to analyze the correlation between the variable posture in the sagittal plane and the scoliotic variables. Material and methods. The study involved 28 girls aged 7-18 years with scoliotic posture and scoliosis. Body posture as well as the spine were examined using Moiré’s spatial photogrammetry and the Exhibeon digital radiography method. Based on the size of the spinal curvature, the following were distinguished: scoliotic postures: 1-9° and scoliosis: ≥10°. Results. There were 21 (75% with scoliotic posture and 7 (25% with scoliosis. The size of the thoracic kyphosis and lumbar lordosis was normal. Conclusions. Between the body postural variables in the sagittal plane and the scoliotic variables, both positive (direct proportional and negative (inversely proportional correlations occurred. In the selection of scoliosis treatment method, the size of the postural variables in the sagittal plane should be taken into account, and each patient’s case should be individually considered.

  13. Multilayer tape cast SOFC – Effect of anode sintering temperature

    DEFF Research Database (Denmark)

    Hauch, Anne; Birkl, Christoph; Brodersen, Karen

    2012-01-01

    Multilayer tape casting (MTC) is considered a promising, cost-efficient, up-scalable shaping process for production of planar anode supported solid oxide fuel cells (SOFC). Multilayer tape casting of the three layers comprising the half cell (anode support/active anode/electrolyte) can potentially...

  14. ICI optical data storage tape: An archival mass storage media

    Science.gov (United States)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  15. Osteomesophycnosis. A new case

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, H.; Lengerke, H.J. von; Mannkopf, H.; Ullrich, K.

    1989-07-01

    A 10-year old, mentally and physically normally developed girl complained of back pain following an accident. Radiological findings revealed an inhomogeneous, coarse osteosclerosis along the endplates and posterior parts of the ovoid shaped vertebral bodies, in the proximal and distal femora, proximal humeri and tibia epiphyses, and along the lateral aspects of the femoral necks. The pelvis presented a mottled appearance of the trabecular pattern at the symphysis pubis and the lateral parts of ischii and sclerosis in the acetabular region. The only laboratory abnormality was a high serum parathormone level. The family history revealed an autosomal dominant inheritance. The name proposed by Maroteaux for this skeletal disorder is osteomesopycnosis, as the lesions were localized to the spine, pelvis and sometimes proximal femur. The skull, ribs, long bones, hands and feet were not involved in the reported 12 cases. Radiographs of this patient showed in addition changes in the hand. This disease must be distinguished from atypical axial osteomalacia. (orig.).

  16. Bilateral sagittal split osteotomy versus distraction osteogenesis for mandibular advancements

    NARCIS (Netherlands)

    Baas, E.M.

    2015-01-01

    The aim of this thesis was to compare the treatment modality of distraction osteogenesis (DO) with the gold standard for mandibular advancement surgery. In fact we compare distraction osteogenesis with the standard of care, which is a conventional bilateral sagittal split osteotomy as described by

  17. Forensic Pollen Evidence from Clothes by the Tape Adhesive Method

    Directory of Open Access Journals (Sweden)

    Chun-Liang Wu

    2006-06-01

    Full Text Available Collection and identification of pollen is becoming important in forensic applications. Many criminal cases have been reported to link suspects to the crime scene by analysis of pollen. Several methods have been used in the pollen collection and analysis, but they are expensive and tedious. Therefore, it is important to develop a simple method to collect pollen grains from clothes. We tried to recover pollen from clothing surface by using the sticky tapes method. The tape adhesive method has been widely used for sample collection for various purposes, but the efficiency of recovery of invisible pollen from clothes has rarely been reported. Therefore, to test the efficiency of the tape adhesive method in recovering pollen from clothes is important. The first author wore clothes that were made from textile S made by the mixture of cotton 60% and polyester fiber 40% to collect pollen from 26 different areas mostly in the northern part of Taiwan and then used cellophane tape D (Sirchie Finger Print Lab., Inc-No. 131LT4 to recover them from different body parts. Twenty-six pollen taxa were detected in different parts of clothes depending upon what kind of plant the first author stayed near. From the results, we concluded that the tape adhesive method is suitable in recovering pollen from clothes. We have suggested that the tape adhesive method could be part of methods for collecting pollen from clothes of suspects. It is simpler, faster and less expensive than other methods.

  18. Fabrication of high edge-definition steel-tape gratings for optical encoders

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  19. Correlation and Reliability of Cervical Sagittal Alignment Parameters between Lateral Cervical Radiograph and Lateral Whole-Body EOS Stereoradiograph

    Science.gov (United States)

    Singhatanadgige, Weerasak; Kang, Daniel G.; Luksanapruksa, Panya; Peters, Colleen; Riew, K. Daniel

    2015-01-01

    Study Design  Retrospective analysis. Objective  To evaluate the correlation and reliability of cervical sagittal alignment parameters obtained from lateral cervical radiographs (XRs) compared with lateral whole-body stereoradiographs (SRs). Methods  We evaluated adults with cervical deformity using both lateral XRs and lateral SRs obtained within 1 week of each other between 2010 and 2014. XR and SR images were measured by two independent spine surgeons using the following sagittal alignment parameters: C2–C7 sagittal Cobb angle (SCA), C2–C7 sagittal vertical axis (SVA), C1–C7 translational distance (C1–7), T1 slope (T1-S), neck tilt (NT), and thoracic inlet angle (TIA). Pearson correlation and paired t test were used for statistical analysis, with intra- and interrater reliability analyzed using intraclass correlation coefficient (ICC). Results  A total of 35 patients were included in the study. We found excellent intrarater reliability for all sagittal alignment parameters in both the XR and SR groups with ICC ranging from 0.799 to 0.994 for XR and 0.791 to 0.995 for SR. Interrater reliability was also excellent for all parameters except NT and TIA, which had fair reliability. We also found excellent correlations between XR and SR measurements for most sagittal alignment parameters; SCA, SVA, and C1–C7 had r > 0.90, and only NT had r < 0.70. There was a significant difference between groups, with SR having lower measurements compared with XR for both SVA (0.68 cm lower, p < 0.001) and C1–C7 (1.02 cm lower, p < 0.001). There were no differences between groups for SCA, T1-S, NT, and TIA. Conclusion  Whole-body stereoradiography appears to be a viable alternative for measuring cervical sagittal alignment parameters compared with standard radiography. XR and SR demonstrated excellent correlation for most sagittal alignment parameters except NT. However, SR had significantly lower average SVA and C1–C7 measurements than XR

  20. Structural properties of superconducting Bi-2223/Ag tapes

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalck Andersen, L.

    2001-05-01

    The structural properties of silver clad high-T{sub c} superconducting ceramic tapes of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} (Bi-2223) have been investigated by means of synchrotron X-ray diffraction (including the 3DXRD microscope setup), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) with energy dispersive X-ray analysis (EDS). By synchrotron X-ray diffraction in situ studies of the phase development during the transformation of (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 1}Cu{sub 2}O{sub x} (Bi-2212) into Bi-2223, the stoichiometry changes and the texture have been performed during annealing in 8% O{sub 2} and in air. Furthermore, an annealing with two high temperature cycles has been performed to study the equilibrium phenomena. During heating (Ca,Sr){sub 2}PbO{sub 4} decomposes at temperatures between 700 deg. C and 840 deg.C. Simultaneously, the Bi-2212 lattice contracts, indicating an incorporation of Pb. Moreover, the grain mis-alignment decreases significantly. In air we have observed that Bi-2212 partly dissociates into (Ca,Sr){sub 2}CuO{sub 3} and a liquid at temperatures above 812 deg. C. At the annealing temperature Bi-2212 and (Ca,Sr){sub 2}CuO{sub 3} react with the liquid to form Bi-2223. The transformation mechanism is discussed. During cooling below {approx}750 deg.C (Ca,Sr){sub 2}CuO{sub 3} and the liquid mainly transform into Bi-2201. Below {approx}780 deg. C Bi-2223 decomposes to 3221. In addition, a two-step cooling experiment and a decomposition study have been performed in 8% O{sub 2}. By TEM the grain and colony size in the c-axis direction, the angles of c-axis tilt grain boundaries and the intergrowth content are investigated. A fully processed tape has on average 50% thicker grains than a tape after the 1st annealing. The angles of c-axis tilt grain boundaries are on average 14 deg. and 26 deg. for the fully processed tape and the tape after the 1st annealing, respectively. The intergrowth content (15%) and

  1. Engineering Critical Current Density Improvement in Ag- Bi-2223 Tapes

    DEFF Research Database (Denmark)

    Wang, W. G.; Seifi, Behrouz; Eriksen, Morten

    2000-01-01

    Ag alloy sheathed Bi-2223 multifilament tapes were produced by the powder-in-tube method. Engineering critical current density improvement has been achieved through both enhancement of critical current density by control of the thermal behavior of oxide powder and by an increase of the filling...... factor of the tapes. Phase evolution at initial sintering stage has been studied by a quench experiment in Ag-Bi-2223 tapes. The content, texture, and microstructure of various phases were determined by XRD and SEM. A novel process approach has been invented in which square wire was chosen rather than...

  2. The inhomogeneities of (Pb,Bi)2223 superconducting tapes and their detection

    International Nuclear Information System (INIS)

    Leeuwen, S. van

    1999-05-01

    This thesis consists of two parts: first, the inhomogeneities that were observed in high temperature superconducting (Pb,Bi)2223 tapes were studied followed by the design of two rigs which were built to detect them. These investigations concentrated on (Pb,Bi)2223 phase high temperature superconducting tapes. Superconductors and their applications were briefly evaluated. It was found that high temperature superconductors have unique properties which cannot be duplicated by their counterparts. However, it was noted that there are significant improvements to be made before they can be commercially viable. An investigation was carried out into the variation of core density within cross sections and along lengths of (Pb,Bi)2223 tapes during fabrication. It was observed that rolling and thermal treatment brought about a non-uniform core density in both these aspects of tile tape. This was followed by an investigation into the effect of core density on the formation of the (Pb,Bi)2223 phase. It was shown that a high core density formed the (Pb,Bi)2223 phase at a slower rate than a lower core density under the thermal treatment. A high core density and a slow heating rate produced smaller 2212 grains at the end of the incubation period. Smaller 2212 grains were thought to be linked to the faster formation of the (Pb,B1)2223 phase. The highest Jc was from a high core density tape which had the smaller 2212 grains at the end of incubation period. Smaller 2212 grains were thought to aid a more homogeneous conversion to the (Pb,Bi)2223 phase. Alloy-sheathed (Pb,Bi)2223 superconducting tapes were produced in order to fabricate a more homogeneous core density. It was found that the alloy sheath (with an addition of 15% wt Ag in the precursor powder) changed the characteristics of the core in several ways: the formation of the (Pb,Bi)2223 phase was homogeneous across the thickness of the core, a smaller 2212 grain size was formed at the end of the incubation period and a higher

  3. Ultrasound assessment of tension-free vaginal tape (TVT).

    Science.gov (United States)

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Posterior Surgery for Adolescent Idiopathic Scoliosis With Pedicle Screws and Ultrahigh-Molecular Weight Polyethylene Tape: Achieving the Ideal Thoracic Kyphosis.

    Science.gov (United States)

    Imagama, Shiro; Ito, Zenya; Wakao, Norimitsu; Ando, Kei; Hirano, Kenichi; Tauchi, Ryoji; Muramoto, Akio; Matsui, Hiroki; Matsumoto, Tomohiro; Sakai, Yoshihito; Katayama, Yoshito; Matsuyama, Yukihiro; Ishiguro, Naoki

    2016-10-01

    Prospective clinical case series. To describe our surgical procedure and results for posterior correction and fusion with a hybrid approach using pedicle screws, hooks, and ultrahigh-molecular weight polyethylene tape with direct vertebral rotation (DVR) (the PSTH-DVR procedure) for treatment of adolescent idiopathic scoliosis (AIS) with satisfactory correction in the coronal and sagittal planes. Introduction of segmental pedicle screws in posterior surgery for AIS has facilitated good correction and fusion. However, procedures using only pedicle screws have risks during screw insertion, higher costs, and decreased postoperative thoracic kyphosis. We have obtained good outcomes compared with segmental pedicle screw fixation in surgery for AIS using a relatively simple operative procedure (PSTH-DVR) that uses fewer pedicle screws. The subjects were 30 consecutive patients with AIS who underwent the PSTH-DVR procedure and were followed for a minimum of 2 years. Preoperative flexibility, preoperative and postoperative Cobb angles, correction rates, loss of correction, thoracic kyphotic angles (T5-T12), coronal balance, sagittal balance, and shoulder balance were measured on plain radiographs. Rib hump, operation time, estimated blood loss, spinal cord monitoring findings, complications, and scoliosis research society (SRS)-22 scores were also examined. The mean preoperative curve of 58.0 degrees (range, 40-96 degrees) was corrected to a mean of 9.9 degrees postoperatively, and the correction rate was 83.6%. Fusion was obtained in all patients without loss of correction. In 10 cases with preoperative kyphosis angles (T5-T12) correction of deformity with PSTH-DVR is equivalent to that of all-pedicle screw constructs. The procedure gives favorable correction, is advantageous for kyphosis compared with segmental screw fixation, and uses the minimum number of pedicle screws. Therefore, the PSTH-DVR procedure may be useful for treatment of idiopathic scoliosis.

  5. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2005-01-01

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample

  6. Comparison of self-field effects between Bi-2223/Ag tapes and pancake coils

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)]. E-mail: alam643@yahoo.com; Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Building Li Zhai, Room 209, Beijing 100084 (China)

    2005-08-15

    Knowledge on self-field behavior in HTS tape and coil becomes important for the design of HTS devices. We report on the comparative nature and influence of self-field in Bi-2223/Ag tape and pancake coils in terms of critical current and ac loss. Measured dc and ac properties of short tape and pancake coils are verified based on the self-field. It is proved that perpendicular component of self-field acting in opposite direction at the two halves of tape-width determines critical current in short tape and single-turn coil. On the other hand, perpendicular component of self-field pointed in the same direction at the two halves of tape-width determines critical current in multi-turn coils. Influence of magnitude and orientation of self-field on ac loss is also investigated for a series of pancake coils based on the measured self-field ac loss in short sample.

  7. Tape casting and partial melting of Bi-2212 thick films

    Energy Technology Data Exchange (ETDEWEB)

    Buhl, D.; Lang, T.; Heeb, B. [Nichtmetallische Werkstoffe, Zuerich (Switzerland)] [and others

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  8. Ankle Taping Does Not Impair Performance in Jump or Balance Tests

    OpenAIRE

    Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier

    2008-01-01

    This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests a...

  9. Spinal sagittal imbalance in patients with lumbar disc herniation: its spinopelvic characteristics, strength changes of the spinal musculature and natural history after lumbar discectomy.

    Science.gov (United States)

    Liang, Chen; Sun, Jianmin; Cui, Xingang; Jiang, Zhensong; Zhang, Wen; Li, Tao

    2016-07-22

    Spinal sagittal imbalance is a widely acknowledged problem, but there is insufficient knowledge regarding its occurrence. In some patients with lumbar disc herniation (LDH), their symptom is similar to spinal sagittal imbalance. The aim of this study is to illustrate the spinopelvic sagittal characteristics and identity the role of spinal musculature in the mechanism of sagittal imbalance in patients with LDH. Twenty-five adults with spinal sagittal imbalance who initially came to our clinic for treatment of LDH, followed by posterior discectomy were reviewed. The horizontal distance between C7 plumb line-sagittal vertical axis (C7PL-SVA) greater than 5 cm anteriorly with forward bending posture is considered as spinal sagittal imbalance. Radiographic parameters including thoracic kyphotic angle (TK), lumbar lordotic angle (LL), pelvic tilting angle (PT), sacral slope angle (SS) and an electromyography(EMG) index 'the largest recruitment order' were recorded and compared. All patients restored coronal and sagittal balance immediately after lumbar discectomy. The mean C7PL-SVA and trunk shift value decreased from (11.6 ± 6.6 cm, and 2.9 ± 6.1 cm) preoperatively to (-0.5 ± 2.6 cm and 0.2 ± 0.5 cm) postoperatively, while preoperative LL and SS increased from (25.3° ± 14.0° and 25.6° ± 9.5°) to (42.4° ± 10.2° and 30.4° ± 8.7°) after surgery (P imbalance caused by LDH is one type of compensatory sagittal imbalance. Compensatory mechanism of spinal sagittal imbalance mainly includes a loss of lumbar lordosis, an increase of thoracic kyphosis and pelvis tilt. Spinal musculature plays an important role in spinal sagittal imbalance in patients with LDH.

  10. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    LENUS (Irish Health Repository)

    Nolan, Damien

    2009-01-01

    BACKGROUND: Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape\\'s immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. METHODS: 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. RESULTS: Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. CONCLUSION: Low-Dye tape\\'s initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued

  11. Effect of the Kinesio tape to muscle activity and vertical jump performance in healthy inactive people

    Directory of Open Access Journals (Sweden)

    Lu Szu-Ching

    2011-08-01

    Full Text Available Abstract Background Elastic taping applied on the triceps surae has been commonly used to improve the performance of lower extremities. However, little objective evidence has been documented. The purpose of this study was to investigate the effect of elastic taping on the triceps surae during a maximal vertical jump. It was hypothesized that elastic taping to the triceps surae would increase muscle activity and cause positive effect to jump height. Methods Thirty-one healthy adults (19 males and 12 females with mean age, body weight and height for 25.3 ± 3.8 years old, 64.1 ± 6.2 kg, and 169.4 ± 7.3 cm, respectively were recruited. All participants performed vertical jump tests prior to (without taping and during elastic taping. Two elastic tapes, Kinesio tape and Mplacebo tape from two different manufacturers, were applied to the participants, respectively. Results The results showed that the vertical ground reaction force increased when Kinesio tape was applied even when the height of jump remained about constant. However, the height of the jump decreased, and there was no difference on the vertical ground reaction force in Mplacebo taping group. Although the EMG activity of medial gastrocnemius tended to increase in Kinesio taping group, we did not see differences in EMG activity for the medial gastrocnemius, tibialis anterior and soleus muscles in either group. Conclusions Based on the varied effects of Kinesio tape and Mplacebo tape, different intervention technique was suggested for specific purpose during vertical jump movement. Mplacebo tape was demanded for the benefits of stabilization, protection, and the restriction of motion at the ankle joint. On the other hand, the findings may implicate benefits for medial gastrocnemius muscle strength and push-off force when using Kinesio tape.

  12. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    Science.gov (United States)

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  13. ?Lumbar Degenerative Kyphosis? Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception

    OpenAIRE

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-01-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal...

  14. CORRELATION BETWEEN OBESITY, SAGITTAL BALANCE AND CLINICAL OUTCOME IN SPINAL FUSION

    Directory of Open Access Journals (Sweden)

    Marcel Machado da Motta

    2015-09-01

    Full Text Available Objective:To correlate obesity with radiographic parameters of spinal and spinopelvic balance in patients undergoing spinal arthrodesis, and to correlate obesity with clinical outcome of these patients.Methods:Observational retrospective study including patients who underwent spinal arthrodesis, with minimum follow-up period of three months. We measured waist circumference, as well as height and weight to calculate body mass index (BMI and obtained radiographs of the total column. The clinical parameters studied were pain by visual analog scale (VAS and the Oswestry questionnaire (ODI. Obesity correlated with radiographic parameters of the sagittal and spinopelvic balance and postoperative clinical parameters.Results:32 patients were analyzed. The higher the BMI, the greater the value of VAS found, but without statistical significance (p=0.83. There was also no correlation between BMI and the ODI questionnaire. Analyzing the abdominal circumference, there was no correlation between the VAS and ODI. There was no correlation between BMI or waist circumference and the radiographic parameters of global spinopelvic sagittal alignment. Regarding the postoperative results, there was no correlation between the mean BMI and waist circumference and the postoperative results for ODI and VAS (p=0.75 and p=0.7, respectively.Conclusions:The clinical outcomes of patients who undergone spinal fusion were not affected by the BMI and waist circumference. Also, there was no correlation between radiographic parameters of spinal and spinopelvic sagittal balance with obesity in patients previously treated with arthrodesis of the spine.

  15. Differences of Sagittal Lumbosacral Parameters between Patients with Lumbar Spondylolysis and Normal Adults.

    Science.gov (United States)

    Yin, Jin; Peng, Bao-Gan; Li, Yong-Chao; Zhang, Nai-Yang; Yang, Liang; Li, Duan-Ming

    2016-05-20

    Recent studies have suggested an association between elevated pelvic incidence (PI) and the development of lumbar spondylolysis. However, there is still lack of investigation for Han Chinese people concerning the normal range of spinopelvic parameters and relationship between abnormal sagittal parameters and lumbar diseases. The objective of the study was to investigate sagittal lumbosacral parameters of adult lumbar spondylolysis patients in Han Chinese population. A total of 52 adult patients with symptomatic lumbar spondylolysis treated in the General Hospital of Armed Police Force (Beijing, China) were identified as the spondylolysis group. All the 52 patients were divided into two subgroups, Subgroup A: 36 patients with simple lumbar spondylolysis, and Subgroup B: 16 patients with lumbar spondylolysis accompanying with mild lumbar spondylolisthesis (slip percentage spondylolysis group and the control group with independent-sample t- test. There were no statistically significant differences of all seven sagittal lumbosacral parameters between Subgroup A and Subgroup B. PI, PT, SS, and LL were higher (P spondylolysis group than those in the control group, but STA was lower (P spondylolysis group. Current study results suggest that increased PI and decreased STA may play important roles in the pathology of lumbar spondylolysis in Han Chinese population.

  16. Identification and quantification of glue-like off-odors in elastic therapeutic tapes.

    Science.gov (United States)

    Denk, Philipp; Buettner, Andrea

    2018-05-01

    Elastic therapeutic tapes are an important tool in the field of physical therapy and medicine. These tapes contain types of adhesive. However, sensory evaluations revealed the release of pronounced and irritating odors of the tapes. Negative odors were, amongst others, reported in elastic therapeutic tapes containing acrylic adhesives. In this study, the odor of four different tape samples was evaluated applying a descriptive analysis approach carried out by a trained sensory panel. Afterwards, the volatile compounds were recovered from the samples by solvent extraction and isolated by solvent-assisted flavor evaporation (SAFE). The obtained distillates were subsequently analyzed by gas chromatography-olfactometry (GC-O) and two-dimensional GC-O coupled with mass spectrometry (2D-GC-MS/O). To determine the most potent odorants in the distillates, odor extract dilution analyses (OEDA) were carried out. Thirty-one odorants were successfully identified using this approach, which were all described for the first time as odorants in tapes. Amongst the set of volatiles, unsaturated and saturated aldehydes were present, eliciting fatty, soapy, and citrus-like odor impressions, as well as a range of glue-like, moldy, and fruity smelling odor-active volatiles, such as 2-ethyl-1-hexanol, butyl benzoate, and 3-phenyltoluene. Based on their relative intensities, the concentrations of the glue-like smelling substances were determined: 2-ethyl-1-hexanol, present in all samples, was determined with concentrations ranging from 10 to 200 mg/kg in the investigated tapes.

  17. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  18. Device for stretching tapes or cables intended for manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Baudoin, J C; Oger, R

    1975-03-06

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device.

  19. Sagittal x-ray beam deviation at asymmetric inclined diffractors

    Czech Academy of Sciences Publication Activity Database

    Korytár, D.; Hrdý, Jaromír; Artemiev, Nikolai; Ferrari, C.; Freund, A.

    2001-01-01

    Roč. 8, - (2001), s. 1136-1139 ISSN 0909-0495 R&D Projects: GA MŠk OK 305; GA MPO PZ-CH/22 Institutional research plan: CEZ:AV0Z1010914 Keywords : x-ray optics * Si(111) W/grooved crystals * inclined diffraction * out-of-diffraction-plane beams * sagittal focusing Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.519, year: 2001

  20. Ring shaped laser for tape winding of an endless tube

    NARCIS (Netherlands)

    Leonardus, Lucky

    2012-01-01

    AFPT is a start-up company that provides laser-assisted technology for the production of a pressurized component such as tube, pressure vessel, etc made from or strengthened by fiber reinforced plastic (FRP) tape. The tape is laid precisely by a machine head (connected to a robot), melted with a

  1. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    Science.gov (United States)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  2. Pinning Mechanisms in YBCO Tapes

    CERN Document Server

    Spera, Marcello; Ballarino, Amalia

    2015-01-01

    In this thesis work, a study on flux pinning mechanisms of commercial YBCO tapes is presented. This study has been performed via critical current characterization using transport (via direct I-V curves) and magnetization (via a Vibrating Sample Magnetometer) measurements. The latter ones turned out to be better concerning the comprehension of the pinning landscape of the provided samples, as a wider range of magnetic fields and temperatures is available for those measurements in the setup I used. The comparison of the experimental data with existing theoretical models allowed me to draw a picture of the pinning mechanisms underlying in each sample, and they turned out to be quite different one another. Moreover, for high-performance research tapes, another interesting feature has been found: the counterplay between the self-field critical current and the in-field one. Very well engineered artificial pinning structures limit the self-field critical current density due to the hi...

  3. Tape functionality: position, change in shape, and outcome after TVT procedure--mid-term results.

    Science.gov (United States)

    Kociszewski, Jacek; Rautenberg, Oliver; Kolben, Sebastian; Eberhard, Jakob; Hilgers, Reinhard; Viereck, Volker

    2010-07-01

    This study evaluates the relevance of the tape position and change in shape (tape functionality) under in vivo conditions for mid-term outcome. Changes in the sonographic tension-free vaginal tape (TVT) position relative to the percentage urethral length and the tape-urethra distance were determined after 6 and 48 months in 41 women with stress urinary incontinence. At 48 months, 76% (31/41) of women were cured, 17% (7/41) were improved, and 7% (3/41) were failures. Disturbed bladder voiding was present in 12% (5/41), de novo urge incontinence in 7% (3/41). The median TVT position was at 63% of urethral length. Median tape-urethra distance was 2.7 mm, ranging from 2.9 mm in continent patients without complications to 1.1 mm in those with obstructive complications. Patients with postoperative urine loss had a median distance of 3.9 mm. The tape was stretched at rest and C-shaped during straining in 15 of 41 women (37%) at 48 months (all continent). Patients with this tape functionality at 6 months were also cured at 48 months in 86% of cases (19/22), and only 14% (3/22) showed recurrent incontinence. Mid-term data suggest an optimal outcome if the tape is positioned at least 2 mm from the urethra at the junction of the middle and distal thirds. Patients with optimal tape functionality at 6 months are likely to show mid-term therapeutic success.

  4. Optimization of the tape placement process parameters for carbon–PPS composites

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, B.; Visser, Roy; Akkerman, Remko

    2013-01-01

    The interrelation between process parameters, material properties and interlaminar bond strength is investigated for the laser assisted tape placement process. Unidirectionally carbon reinforced poly(phenylene sulfide) (PPS) tapes were welded onto carbon woven fabric reinforced PPS laminates. The

  5. Leak isolation self-repairing tape for a water storage vessel and piping against holes

    International Nuclear Information System (INIS)

    Nagaya, Kosuke; Sekiguchi, Takahiro; Chen, Zhichao; Murakami, Iwanori

    2007-01-01

    A new type taping for a water storage vessel or piping is presented, in which water leakage is isolated automatically by its self-repairing mechanism against holes. The self-repairing unit (sealant layer) is consisting of three pieces of net with polymer particles inside lattices. Polymer particles, which expand their volume with water, is used for having self-repairing forces. In ordinary tapes, water leaks along the boundary between the tape and the vessel. In order to retain the leak isolation force, this article first discusses a method for making the sealant tape, then develops a method for fixing the sealant to the vessel. The portion of water leakage can be checked on this tape, and the method of detecting the hole or crack portion of the vessel is also presented by using the tape. (author)

  6. Sagittal-lung CT measurements in the evaluation of asthma-COPD overlap syndrome: a distinctive phenotype from COPD alone.

    Science.gov (United States)

    Qu, Yanjuan; Cao, Yiyuan; Liao, Meiyan; Lu, Zhiyan

    2017-07-01

    This study aimed at investigating the capability of sagittal-lung computed tomography (CT) measurements in differentiating chronic obstructive pulmonary disease (COPD) and asthma-COPD overlap syndrome (ACOS). Clinical and high-resolution CT of 229 patients including 123 pure COPD patients and 106 ACOS patients were included. Sagittal-lung CT measurements in terms of bilateral lung height (LH), anterior-posterior lung diameter (APLD), diaphragm height (DH), and anterior sterno-diaphragmatic angle (ASDA), as well as inter-pulmonary septum length (IPSL) on axial images were measured both before and after bronchodilator (BD) administration. Comparisons of clinical characteristics and CT measurements between patient groups were performed. All pre-BD quantitative sagittal features measuring diaphragm flattening and hyperinflation were not significantly different between patients with COPD and patients with ACOS (P values all >0.05). Following BD administration, the ACOS patients exhibited lower left LH, bilateral APLD, and bilateral ASDA, but higher right DH, compared to pure COPD patients (P values all <0.05). Right LH, left DH and IPSL were not significantly different between patient groups. Besides, variations of all sagittal-lung CT measurements were significantly larger in patients with ACOS than in patients with pure COPD (P values all <0.001) and showed high performance in differentiating these two kinds of patient, with diagnostic sensitivities ranging from 76.4 to 97.2%, specificities ranging from 86.2 to 100.0%, and accuracies ranging from 80.9 to 90.7%. Sagittal-lung CT measurements allow for differentiating patients with ACOS from those with pure COPD. The ACOS patients had larger post-BD variations of sagittal-lung CT measurements than patients with pure COPD.

  7. Silica frit formulation for low temperature co-fired ceramic tapes (LTCC)

    International Nuclear Information System (INIS)

    Nor Hayati Alias; Che Seman Mahmood

    2006-01-01

    Glassifier agents or so called fluxes could function to lower down the melting temperature of a ceramic material. Two types of silica based glass frits have been formulated to undergo vitrification at temperature lower than 1000 degree C. Frit A powder is composing of 11% Sodium Carbonate, 11% Calcium Oxide,15% Plumbum Oxide and 10% MgO while Frit B is composing of 12% Boron Oxide, 5% Ceria, 11% Sodium Carbonate and 2% Magnesium Oxide as glassifier agent in Silica powder. Two different ceramic slurries were made from a-alumina powder with addition of either Frit A or Frit B and also dispersant, binder and plasticizers, followed by casting into 0.04 mm thickness alumina green tapes. The tapes were then fired at temperature 1000 degree C to burn out plastic binder system and to vitrify the glass frits. Scanning Electron Microscopy (SEM)/EDX techniques were carried out to observe the changes in microstructure of the tape due to vitrication of glass frits. Comparisons were made with alumina green tapes without any glass frit component and with Commercial LTCC DuPont 951 tape. (Author)

  8. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    Science.gov (United States)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  9. Patient goals after tension free vaginal tape operation

    DEFF Research Database (Denmark)

    Glavind, Karin; Bjørk, Jonna; Kousgaard, Sabrina Just

    INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology and Obstetr......INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology...

  10. New concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1980-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 millimeter wide recording tape 116 meters long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation

  11. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  12. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    Science.gov (United States)

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-14

    BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.

  13. Variations of cervical lordosis and head alignment after pedicle subtraction osteotomy surgery for sagittal imbalance.

    Science.gov (United States)

    Cecchinato, R; Langella, F; Bassani, R; Sansone, V; Lamartina, C; Berjano, P

    2014-10-01

    The variations of the cervical lordosis after correction of sagittal imbalance have been poorly studied. The aim of our study is to verify whether the cervical lordosis changes after surgery for sagittal imbalance. Thirty-nine patients were included in the study. Cervical, thoracic and lumbar spine, pelvic and lower-limb sagittal parameters were recorded. The cranial alignment was measured by the newly described Cranial Slope. The global cervical kyphosis (preop -43°, postop -31.5°) and the upper (preop -24.1°, postop -20.2°) and lower cervical kyphosis (preop -18.1°, postop -9.2°) were significantly reduced after surgical realignment of the trunk. A positive linear correlation was observed between the changes in T1 slope and the lower cervical lordosis, and between T1 slope and the global cervical alignment. The cervical lordosis is reduced by surgical correction of malalignment of the trunk, suggesting an adaptive role to maintain the head's neutral position.

  14. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Directory of Open Access Journals (Sweden)

    Yang Yang, Ying Fang, Xini Zhang, Junliang He, Weijie Fu

    2017-12-01

    Full Text Available The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively performed a weight-bearing dorsiflexion (WB-DF maneuver, drop jumps (DJs, and lay-up jumps (LJs. Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041 was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028 and power (p = 0.022 were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  15. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-12-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion-extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  16. The effect of rigid taping with tension on mechanical displacement of the skin and change in pain perception.

    Science.gov (United States)

    Chen, Shu-Mei; Lo, Sing Kai; Cook, Jill

    2018-04-01

    To investigate the effect of rigid taping that induces mechanical displacement of the skin on pain perception. Single group experiment design with repeated measures. Twenty-three active healthy volunteers (12 men and 11 women) participated in the study. All participants received three different taping procedures: no tape, taping with tension, and taping without tension. The order of three taping conditions was randomised. Skin displacement was measured during taping with tension. A pressure algometer was used to measure the level of pain perception once before taping, and again after each taping condition, in one testing session. The participants were blind to the values of their pressure pain threshold (PPT) during the experimental period. The mean±SD skin displacement in the condition of taping with tension was 2.58±0.49cm. There were significant differences in PPT between taping with tension and taping without tension (mean difference (mean diff)±standard error (SE) 36.43±4.22kPa, p=0.000) and no tape (mean diff±SE 44.31±3.13kPa, p=0.000). No significant difference in PPT between no tape and taping without tension was found (mean diff±SE 7.88±2.83kPa, p=0.067). Taping with tension increases the threshold of pressure pain perception. Therefore, stretch and compression caused by rigid taping with tension could disturb the nociceptive signal transmission and alter pain perception. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Solayar GN

    2017-07-01

    Full Text Available INTRODUCTION: Optimal coronal and sagittal component positioning is important in achieving a successful outcome following total knee arthroplasty (TKA. Modalities to determine post-operative alignment include plain radiography and computer tomography (CT imaging. This study aims to determine the accuracy and reliability of plain radiographs in measuring coronal and sagittal alignment following TKA. MATERIALS AND METHODS: A prospective, consecutive study of 58 patients undergoing TKA was performed comparing alignment data from plain radiographs and CT imaging. Hip- knee-angle (HKA, sagittal femoral angle (SFA and sagittal tibial angle (STA measurements were taken by two observers from plain radiographs and compared with CT alignment. Intra- and inter-observer correlation was calculated for each measurement. RESULTS: Intra-observer correlation was excellent for HKA (r>0.89 with a mean difference of 0.95 and STA (r>0.8 compared to SFA (r=0.5. When comparing modalities (radiographs vs CT, HKA estimations for both observers showed the least maximum and mean differences while SFA observations were the least accurate. CONCLUSION: Radiographic estimation of HKA showed excellent intra- and inter-observer correlation and corresponds well with CT imaging. However, radiographic estimation of sagittal plane alignment was less reliably measured and correlated less with CT imaging. Plain radiography was found to be inferior to CT for estimation of biplanar prosthetic alignment following TKA.

  18. Standard Practice for Sampling for Particulate Contamination by Tape Lift

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques. 1.2 This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing. 1.3 The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice. 1.4 This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested or for which the susceptibility to damage is unknown is not recommended. In general, metal...

  19. Experimental Investigations of Woven Textile Tape as Strain Sensor

    Science.gov (United States)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  20. Does the application of kinesiotape change scapular kinematics in healthy female handball players?

    Science.gov (United States)

    Van Herzeele, M; van Cingel, R; Maenhout, A; De Mey, K; Cools, A

    2013-11-01

    Elastic taping is widely used in sports medicine for correcting functional alignment and muscle recruitment. However, evidence regarding its influence on scapular dynamic positioning is scarce. This study aimed to investigate the effect of a specific kinesiotaping method on scapular kinematics in female elite handball players without shoulder complaints. 25 athletes (18.0±1.5 years) active in the highest national division were recruited. All subjects received an elastic adhesive tape (K-active tape©) with the purpose to correct scapular position. 3-dimensional scapular motion measurements were performed (Fastrak®) during humeral elevation in the sagittal, frontal and scapular plane. The results showed that taping has a moderate to large effect (Cohen's d>0.7) towards scapular posterior tilting, in all 3 planes of humeral movement and for all angles of elevation (mean posteriorizing effect of 4.23 °, 3.23 ° and 4.33 ° respectively for elevation in the sagittal, frontal and scapular plane, p0.7). Together these results suggest that kinesiotape application causes positive changes in scapular motion. This could support its use in sports medicine for preventing shoulder problems in overhead athletes. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Comparison of prostate contours between conventional stepping transverse imaging and Twister-based sagittal imaging in permanent interstitial prostate brachytherapy.

    Science.gov (United States)

    Kawakami, Shogo; Ishiyama, Hiromichi; Satoh, Takefumi; Tsumura, Hideyasu; Sekiguchi, Akane; Takenaka, Kouji; Tabata, Ken-Ichi; Iwamura, Masatsugu; Hayakawa, Kazushige

    2017-08-01

    To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultrasonography probe was inserted, with the patient in lithotomy position. Transverse images were obtained with stepping movement of the transverse transducer. In the same patient, sagittal images were also obtained through rotation of the sagittal transducer using the "Twister" mode. The differences of prostate size among the two types of image acquisitions were compared. The relationships among the difference of the two types of image acquisitions, dose-volume histogram (DVH) parameters on the post-implant computed tomography (CT) analysis, as well as other factors were analyzed. The sagittal image acquisitions showed a larger prostate size compared to the transverse image acquisitions especially in the anterior-posterior (AP) direction ( p transverse image acquisitions was correlated to DVH parameters such as D 90 ( R = 0.518, p = 0.019), and V 100 ( R = 0.598, p = 0.005). There were small but significant differences in the prostate contours between the transverse and the sagittal planning image acquisitions. Furthermore, our study suggested that the differences between the two types of image acquisitions might correlated to dosimetric results on CT analysis.

  2. Control program for punched paper tape for the PDP-8/1 computer

    International Nuclear Information System (INIS)

    German, U.

    1976-01-01

    A program was developed for the PDP-8/1 computer to control the punched paper tape supplied by the measuring instruments. Any departure from the program is detected by an optical reader which stops the tape and displays the error on an accumulator. This program which is suitable for large amounts of data punched on paper tape has been in use at the Beer-Sheva laboratories for detecting errors in the sample changing operation. (B.G.)

  3. Fabrication and properties of Ag-Bi2223 tapes with resistive barriers for filament decoupling

    International Nuclear Information System (INIS)

    Inada, Ryoji; Fukumoto, Yohei; Yasunami, Taeko; Nakamura, Yuichi; Oota, Akio; Li Chengshang; Zhang Pingxiang

    2007-01-01

    In this paper, we prepared the Bi2223 multifilamentary tapes with Ca 2 CuO 3 + Bi2212 as interfilamentary resistive barriers to suppress the electromagnetic coupling among the filaments under AC external magnetic field. The tapes with thin barrier layers of Ca 2 CuO 3 + 30 wt% Bi2212 around the filaments were prepared by using a standard powder-in-tube (PIT) method. The outside surface of monocore Ag-sheathed rods was coated by barrier materials. Then, the several coated monocore wires were stacked and packed into another Ag or Ag-Mg alloy tube. The packed tube was drawn and rolled into tape shape. The tape was subsequently sintered to form Bi2223 phase inside filaments. For the characterization of tapes, X-ray diffraction measurements were performed to investigate the phase formation inside the filaments. The uniformity of transport properties (J c ) for barrier tapes were evaluated on the order of several metre lengths and compared with the result for the tapes without barriers. Finally, AC loss characteristics under AC parallel transverse magnetic field were investigated to examine the effect of introducing the barriers on the filament decoupling

  4. Sagittal synostosis: II. Cranial morphology and growth after the modified pi-plasty

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the postoperative cranial growth and morphology after a modified pi-plasty for sagittal synostosis. The shape of the skull of 82 patients with isolated premature synostosis of the sagittal suture ( SS group) operated on with a modified pi-plasty was studied...... developed by Kreiborg, which included the digitisation of 89 landmarks of the calvaria, cranial base, and orbit ( 43 in the lateral and 46 in the frontal projections), the production of mean shape plots for each group, and the intergroup comparison of a series of 78 variables ( linear distance between...... selected landmarks, and angles defined by groups of three landmarks). Paired and unpaired t tests were used to assess the differences between the variables studied. These were accepted as significant for values of p...

  5. Is application of Kinesio tape to treat hyperlordosis more effective on abdominal muscles or hamstrings?

    Directory of Open Access Journals (Sweden)

    Sara Abolahrari Shirazi

    2018-01-01

    Full Text Available Background: Hyperlordosis is defined as an abnormal increase in the lumbar arch of >40°. This study compared two taping techniques include abdominal muscles and hamstrings taping for the treatment of lumbar hyperlordosis. Materials and Methods: The randomized clinical trial was performed in Shiraz, Iran, during June and September 2014. Thirty women aged 20–45 years old with at least 40° lumbar lordosis participated. The women were randomized into two groups (n = 15. Abdominal muscles taping was performed for the first group, whereas the other group underwent hamstrings taping with 30% tension. Lumbar lordosis was measured before, immediately after, and 24 h after taping. The two-way repeated measures analysis of variance was used to compare the two groups for lumbar lordosis angle. Results: No significant differences were detected between the lumbar lordosis angles before and immediately after taping in the two groups (P > 0.05. However, a significant reduction was observed in lordosis angle in the abdominal group and the hamstring group 24 h after taping relative to before intervention (P < 0.01. Conclusion: Taping of the abdominal and hamstring muscles was not effective immediately, whereas it decreased lordosis after 24 h.

  6. Numerical Modeling of the Side Flow in Tape Casting of a Non-Newtonian Fluid

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2013-01-01

    in the tape casting process is modeled numerically with ANSYS FLUENT in combination with an Ostwald-de Waele power law constitutive equation. Based on rheometer experiments, the constants in the Ostwald-de Waele power law are identified for the considered LSM material and applied in the numerical modeling......One of the most common ways used to produce multilayer ceramics (MLC) is tape casting. In this process, the dried tape thickness is of great interest to control the desired products and applications. One of the parameters that influences the final tape thickness is the side flow factor (a) which...... is mostly measured at the end of the process by a volumetric comparison of the tape which flowed outside the casting width to the tape within the casting width. This phenomenon has not been predicted theoretically yet in the literature. In this study, the flow of (La0.85Sr0.15)0.9MnO3 (LSM) slurry...

  7. Effects of functional taping compared with sham taping and minimal intervention on pain intensity and static postural control for patients with non-specific chronic low back pain: a randomised clinical trial protocol.

    Science.gov (United States)

    Jassi, F J; Del Antônio, T; Moraes, R; George, S Z; Chaves, T C

    2017-06-01

    To investigate the immediate and 1-month effects of functional taping to lumbar spine for pain intensity and postural control in patients with chronic non-specific low back pain. Randomised clinical trial. One hundred and twenty participants aged 18 to 50 years. Participants will be allocated at random to receive one of three interventions: functional star-shape taping for 7 days, sham functional taping for 7 days or minimal intervention, one session. The primary outcomes will be pain intensity and postural control. Four measurements of static posturography will be conducted: pre-intervention, immediately after application of the tape, 7 days post-intervention (after removal of the tape) and 1-month follow-up. The secondary outcomes will be low-back-pain-related disability, global perceived effect of treatment and fear avoidance beliefs. Primary and secondary outcomes will be assessed on three occasions: pre-intervention, 7 days post-intervention and at 1-month follow-up. All statistical analyses will be conducted following intention-to-treat principles, and the treatment effects will be calculated using linear mixed models. The results of this study will determine the effects of functional taping on pain intensity and postural control compared with sham taping and minimal intervention. NCT02546466. Copyright © 2016 Chartered Society of Physiotherapy. All rights reserved.

  8. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    Science.gov (United States)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  9. TVT ABBREVO: cadaveric study of tape position in foramen obturatum and adductor region.

    Science.gov (United States)

    Hubka, Petr; Nanka, Ondrej; Masata, Jaromir; Martan, Alois; Svabik, Kamil

    2016-07-01

    The aim of the study was to describe fixation of the TVT ABBREVO and establish whether the tape penetrates through obturator muscles and membrane (obturator complex) into the adductor region and, if so, how far it penetrates. Eight formalin-embalmed female cadavers were used to simulate TVT ABBREVO surgery (totalling 16 insertions). Following tape insertion, dissection was performed and ends of the tape were identified. In cases of penetration, the length of tape penetrating into the adductor region was measured. Of the 16 cases, the tape ended in the obturator membrane in eight, in the internal obturator muscle in one, and penetrated through the obturator membrane into the external obturator muscle in five, where it remained. In two cases, it penetrated through the obturator internus muscle, obturator membrane and obturator externus muscle into the group of thigh adductors; one penetration was by 3 mm and the second by 10 mm. No contact with the obturator nerve or its branches was noted in any case. No TVT contact with the obturator nerve was noted; tape penetrated into the adductor region in two of the 16 cases.

  10. Modelling of fluid flow in tape casting of thin ceramics: Analytical approaches and numerical investigations

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Many startup products such as multilayered inductors, multilayered varistors, piezoelectrics, ceramic fuel cells and lithium ion battery...... components are dependent upon tape casting technology. One of the growing sciences in the processing of ceramics by tape casting is the use of fluid flow analysis to control and enhance the final tapes. The fluid dynamics analysis of the ceramic slurries during tape casting is an efficient mean to elucidate...... the physical parameters crucial to the process. A review of the development of the tape casting process with particular focus on modelling the material flow is presented and in this context the current status is examined and future potential discussed....

  11. PERFORMANCE CHARACTERISTICS OF PARABOLIC SOLAR COLLECTOR WATER HEATER SYSTEM FITTED WITH NAIL TWISTED TAPES ABSORBER

    Directory of Open Access Journals (Sweden)

    K. SYED JAFAR

    2017-03-01

    Full Text Available In this paper, the experimental heat transfer, friction loss and thermal performance data for water flowing through the absorber tube fitted with two different twisted tape configurations in parabolic trough collector (PTC are presented. In the present work, a relative experimental study is carried out to investigate the performance of a PTC influenced by heat transfer through fluidabsorber wall mixing mechanism. The major findings of this experiment show that heat transport enhancement in the nail twisted tape collector perform significantly better than plain twisted tapes and also show that the smallest twisted tape ratio enhances the system performance remarkably maximizing the collector efficiency. The results suggest that the twisted tape and nail twisted tape would be a better option for high thermal energy collection in laminar region of the PTC system.

  12. Thermomechanical Analysis of Shape-Memory Composite Tape Spring

    Science.gov (United States)

    Yang, H.; Wang, L. Y.

    2013-06-01

    Intelligent materials and structures have been extensively applied for satellite designs in order to minimize the mass and reduce the cost in the launch of the spacecraft. Elastic memory composites (EMCs) have the ability of high-strain packaging and shape-memory effect, but increase the parts and total weight due to the additional heating system. Shape-memory sandwich structures Li and Wang (J. Intell. Mater. Syst. Struct. 22(14), 1605-1612, 2011) can overcome such disadvantage by using the metal skin acting as the heating element. However, the high strain in the micro-buckled metal skin decreases the deployment efficiency. This paper aims to present an insight into the folding and deployment behaviors of shape-memory composite (SMC) tape springs. A thermomechanical process was analyzed, including the packaging deformation at an elevated temperature, shape frozen at the low temperature and shape recovery after reheating. The result shows that SMC tape springs can significantly decrease the strain concentration in the metal skin, as well as exhibiting excellent shape frozen and recovery behaviors. Additionally, possible failure modes of SMC tape springs were also analyzed.

  13. Particle image velocimetry measurements of 2-dimensional velocity field around twisted tape

    Energy Technology Data Exchange (ETDEWEB)

    Song, Min Seop; Park, So Hyun; Kim, Eung Soo, E-mail: kes7741@snu.ac.kr

    2016-11-01

    Highlights: • Measurements of the flow field in a pipe with twisted tape were conducted by particle image velocimetry (PIV). • A novel matching index of refraction technique utilizing 3D printing and oil mixture was adopted to make the test section transparent. • Undistorted particle images were clearly captured in the presence of twisted tape. • 2D flow field in the pipe with twisted tape revealed the characteristic two-peak velocity profile. - Abstract: Twisted tape is a passive component used to enhance heat exchange in various devices. It induces swirl flow that increases the mixing of fluid. Thus, ITER selected the twisted tape as one of the candidates for turbulence promoting in the divertor cooling. Previous study was mainly focused on the thermohydraulic performance of the twisted tape. As detailed data on the velocity field around the twisted tape was insufficient, flow visualization study was performed to provide fundamental data on velocity field. To visualize the flow in a complex structure, novel matching index of refraction technique was used with 3-D printing and mixture of anise and mineral oil. This technique enables the camera to capture undistorted particle image for velocity field measurement. Velocity fields at Reynolds number 1370–9591 for 3 different measurement plane were obtained through particle image velocimetry. The 2-dimensional averaged velocity field data were obtained from 177 pair of instantaneous velocity fields. It reveals the characteristic two-peak flow motion in axial direction. In addition, the normalized velocity profiles were converged with increase of Reynolds numbers. Finally, the uncertainty of the result data was analyzed.

  14. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    Science.gov (United States)

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  15. The association between whole body sagittal balance and risk of falls among elderly patients seeking treatment for back pain.

    Science.gov (United States)

    Kim, J; Hwang, J Y; Oh, J K; Park, M S; Kim, S W; Chang, H; Kim, T-H

    2017-05-01

    The objective of this study was to assess the association between whole body sagittal balance and risk of falls in elderly patients who have sought treatment for back pain. Balanced spinal sagittal alignment is known to be important for the prevention of falls. However, spinal sagittal imbalance can be markedly compensated by the lower extremities, and whole body sagittal balance including the lower extremities should be assessed to evaluate actual imbalances related to falls. Patients over 70 years old who visited an outpatient clinic for back pain treatment and underwent a standing whole-body radiograph were enrolled. Falls were prospectively assessed for 12 months using a monthly fall diary, and patients were divided into fallers and non-fallers according to the history of falls. Radiological parameters from whole-body radiographs and clinical data were compared between the two groups. A total of 144 patients (120 female patients and 24 male patients) completed a 12-month follow-up for assessing falls. A total of 31 patients (21.5%) reported at least one fall within the 12-month follow-up. In univariate logistic regression analysis, the risk of falls was significantly increased in older patients and those with more medical comorbidities, decreased lumbar lordosis, increased sagittal vertical axis, and increased horizontal distance between the C7 plumb line and the centre of the ankle (C7A). Increased C7A was significantly associated with increased risk of falls even after multivariate adjustment. Whole body sagittal balance, measured by the horizontal distance between the C7 plumb line and the centre of the ankle, was significantly associated with risk of falls among elderly patients with back pain. Cite this article : J. Kim, J. Y. Hwang, J. K. Oh, M. S. Park, S. W. Kim, H. Chang, T-H. Kim. The association between whole body sagittal balance and risk of falls among elderly patients seeking treatment for back pain. Bone Joint Res 2017;6:-344. DOI: 10

  16. Fracture of fusion mass after hardware removal in patients with high sagittal imbalance.

    Science.gov (United States)

    Sedney, Cara L; Daffner, Scott D; Stefanko, Jared J; Abdelfattah, Hesham; Emery, Sanford E; France, John C

    2016-04-01

    As spinal fusions become more common and more complex, so do the sequelae of these procedures, some of which remain poorly understood. The authors report on a series of patients who underwent removal of hardware after CT-proven solid fusion, confirmed by intraoperative findings. These patients later developed a spontaneous fracture of the fusion mass that was not associated with trauma. A series of such patients has not previously been described in the literature. An unfunded, retrospective review of the surgical logs of 3 fellowship-trained spine surgeons yielded 7 patients who suffered a fracture of a fusion mass after hardware removal. Adult patients from the West Virginia University Department of Orthopaedics who underwent hardware removal in the setting of adjacent-segment disease (ASD), and subsequently experienced fracture of the fusion mass through the uninstrumented segment, were studied. The medical records and radiological studies of these patients were examined for patient demographics and comorbidities, initial indication for surgery, total number of surgeries, timeline of fracture occurrence, risk factors for fracture, as well as sagittal imbalance. All 7 patients underwent hardware removal in conjunction with an extension of fusion for ASD. All had CT-proven solid fusion of their previously fused segments, which was confirmed intraoperatively. All patients had previously undergone multiple operations for a variety of indications, 4 patients were smokers, and 3 patients had osteoporosis. Spontaneous fracture of the fusion mass occurred in all patients and was not due to trauma. These fractures occurred 4 months to 4 years after hardware removal. All patients had significant sagittal imbalance of 13-15 cm. The fracture level was L-5 in 6 of the 7 patients, which was the first uninstrumented level caudal to the newly placed hardware in all 6 of these patients. Six patients underwent surgery due to this fracture. The authors present a case series of 7

  17. IMMEDIATE EFFECT OF KINESIO VERSUS MCCONNELL TAPING ON PATELLOFEMORAL PAIN SYNDROME DURING FUNCTIONAL ACTIVITIES- A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Sai Kumar. N

    2015-12-01

    Full Text Available Background: Patellofemoral pain syndrome (PFPS is a condition presenting with anterior knee pain or pain behind the patella (retro-patellar pain. The purpose of the study is to find the immediate effect of Kinesio taping versus McConnell taping in patellofemoral pain syndrome subjects during functional activities- stair ascent, stair descent and squat lift. Methods: An experimental study design with three groups, 45 subjects with patellofemoral pain syndrome was randomized. 15 subjects into each Kinesiotaping group, McConnell group and Sham group. Kinesiotaping group received patellofemoral kinesio taping technique, McConnell group received McConnell taping technique and Sham group received sham taping technique. Outcome measure pain was measured using visual analogue scale during pre and post taping pain levels that were measured during three functional activities: stair ascent, stair descent and squat lift. Results: When analysed within the group using paired ‘t’ test and wilcoxon signed rank test, there is statistically significant improvement in post pain levels in KT, MT and Sham group during stair climbing, stair descent and squat lift. When compared measuring of pre and post pain levels between three groups, there is no significant change in pain level between Kinesio taping and McConnell taping as also compared to sham taping. Conclusion: The study concluded that Kinesio taping, McConnell taping and sham taping shown immediate effect on reducing pain during functional activities such as stair climbing, stair descent and squat lift with greater percentage of pain reduction was found following Kinesiotaping and McConnell taping.

  18. Bulky scalp metastasis and superior sagittal sinus thrombosis from a cervical adenocarcinoma: an unusual case

    International Nuclear Information System (INIS)

    Abhishek, A.; Ouseph, M. M.; Sharma, M.; Sharma, P.; Kamal, V.

    2008-01-01

    Distant cutaneous metastases from cervical malignancies are uncommon, with scalp metastases being exceptional events. We present the case of a 53-year-old postmenopausal lady with adenocarcinoma of the uterine cervix that metastasized to the scalp with superior sagittal sinus thrombosis 8 months after diagnosis. In contrast to the seven prior cases of scalp metastases of cervical squamous cell carcinoma reported in published reports, ours is the first documentation of such an occurrence in cervical adenocarcinoma. Superior sagittal sinus thrombosis has not been reported with this tumour in the past.

  19. Synergistic reinforcement of highly oriented poly(propylene) tapes by sepiolite nanoclay

    NARCIS (Netherlands)

    Bilotti, E.; Deng, H.; Zhang, R.; Lu, D.; Bras, W.; Fischer, H.R.; Peijs, T.

    2010-01-01

    This paper reports the properties of highly oriented nanocomposite tapes based on isotactic PP and needle-like sepiolite nanoclay, obtained by a solid state drawing process. The intrinsic 1D character of sepiolite allows its exploitation in 1D objects, such as oriented polymer fibres and tapes,

  20. Development of Powder-in-Tube Processed Iron Pnictide Wires and Tapes

    KAUST Repository

    Ma, Yanwei

    2011-06-01

    The development of PIT fabrication process of iron pnictide superconducting wires and tapes has been reviewed. Silver was found to be the best sheath material, since no reaction layer was observed between the silver sheath and the superconducting core. The grain connectivity of iron pnictide wires and tapes has been markedly improved by employing Ag or Pb as dopants. At present, critical current densities in excess of 3750 A /cm 2 (I c = 37.5 A) at 4.2 K have been achieved in Ag-sheathed SrKFeAs wires prepared with the above techniques, which is the highest value obtained in iron-based wires and tapes so far. Moreover, Ag-sheathed Sm-1111 superconducting tapes were successfully prepared by PIT method at temperatures as low as ̃ 900 °C, instead of commonly used temperatures of ̃ 1200 °C. These results demonstrate the feasibility of producing superconducting pnictide composite wires, even grain boundary properties require much more attention. © 2010 IEEE.

  1. Mandibular marginal contouring in oriental aesthetic surgery: refined surgical concept and operative procedure.

    Science.gov (United States)

    Satoh, Kaneshige; Mitsukawa, Nobuyuki

    2014-05-01

    In aesthetic mandibular contouring surgery, which is often conducted in Asians, the operative procedure is thought to deliver a more aesthetic mandibular shape by means of contouring conducted as a whole from the ramus to the symphysis. The authors describe the refined concept and operative procedures of mandibular marginal contouring. For the 7-year period from 2004 to 2011, mandibular marginal contouring has been used in 57 consecutive series of Japanese subjects. Patient ages ranged from 18 to 33 years, and the subjects included 15 men and 42 women. The surgery was carried out by cutting off the protruding deformed mandibular margin from the ramus to the symphysis. In 53 of 57 cases, the focus was on angle contouring. Concomitant genioplasty by horizontal osteotomy of the chin was conducted in 42 of 57 cases (recession, advancement, shortening, elongation, and correction of the shift variously). In 22 materials exhibiting bulk around the mandibular, the ramus to the body was excised sagittally and thinned. In all the patients, mandibular marginal contouring from the ramus to the symphysis was completed. Partial masseter muscle resection was conducted in 11 of 57 cases. Mandibular contouring effectively achieved a highly satisfactory result in all cases. The upper portion of the peripheral branch of the trunk of the mental nerve was dissected by an electric scalpel in 1 case but sutured immediately using an 8-0 nylon stitch. Transient palsy of the mental nerve was noticed in a few cases but subsided in 1 to 2 months. No particular complications were encountered. No secondary revision was required in this series. In mandibular angle plasty, mandibular marginal contouring from the ramus to the symphysis should be carried out by cutting off the angle keeping in mind the entire mandibular shape. This concept and the procedure can deliver greater patient satisfaction.

  2. Comparative Study of Skeletal Stability between Postoperative Skeletal Intermaxillary Fixation and No Skeletal Fixation after Bilateral Sagittal Split Ramus Osteotomy

    DEFF Research Database (Denmark)

    Hartlev, Jens; Godtfredsen, Erik; Andersen, Niels Trolle

    2014-01-01

    OBJECTIVES: The purpose of the present study was to evaluate skeletal stability after mandibular advancement with bilateral sagittal split osteotomy. MATERIAL AND METHODS: Twenty-six patients underwent single-jaw bilateral sagittal split osteotomy (BSSO) to correct skeletal Class II malocclusion....

  3. Temporary ectropion therapy by adhesive taping: a case study

    Directory of Open Access Journals (Sweden)

    Habermann Anke

    2008-07-01

    Full Text Available Abstract Introduction Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip. Patients and methods Ten patients with peripheral facial paresis and paralytic ectropion were treated with an adhesive strip to correct paralytic ectropion. We used "Steri-Strips" (45 × 6.0 mm, which were taped on the carefully cleaned skin of the lower eyelid and of the adjacent zygomatic region until the prognosis of the paresis was clarified. In addition to the examiner's evaluation of the lower lacrimal point in the lacrimal lake, subjective improvement of the symptoms was assessed using a visual analogue scale (VAS, 1–10. Results 9 patients reported a clear improvement of the symptoms after adhesive taping. There was a clear regression of tearing (VAS (median = 8; 1 = no improvement, 10 = very good improvement, the cosmetic impairment of the adhesive tape was low (VAS (median = 2.5; 1 = no impairment, 10 = severe impairment and most of the patients found the use of the adhesive strip helpful. There was slight reddening of the skin in one case and well tolerated by the facial skin in the other cases. Conclusion The cause and location of facial nerve damage are decisive for the type of surgical therapy. In potentially reversible facial paresis, procedures should be used that are easily performed and above all reversible without complications. Until a reliable prognosis of the paresis can be made, adhesive taping is suited for the temporary treatment of paralytic ectropion. Adhesive taping is simple and can be performed by the patient.

  4. Technical and economical evaluation of tape drip and drip line irrigation systems in a strawberry greenhouse

    Directory of Open Access Journals (Sweden)

    Soghra HOSSEINIAN

    2016-04-01

    Full Text Available This study was done in a strawberry greenhouse to examine the technical and the economical evaluation of two drip irrigation systems including the tape and the drip line in the northern part of Iran. The result showed that all of the technical indices with tape were higher than drip line, and due to statistical analysis reveal a significant difference (P < 0.05. Yield and water productivity (WP with tape were higher than drip line (P < 0.05. Benefit per drop (BPD and net benefit per drop (NBPD with tape were higher than drip line. Net present value, internal rate of capital return and benefit to cost ratio in drip line were higher than tape. In general, regarding technical evaluation tape was better than drip line, besides according to the economical evaluation the drip ­lines were better than tape.

  5. Elongated grains in cube textured nickel substrate tapes and flat wires

    International Nuclear Information System (INIS)

    Eickemeyer, J; Gueth, A; Holzapfel, B

    2008-01-01

    Cube textured nickel substrate tapes and flat wires with an increased grain aspect ratio were prepared from nickel micro-alloyed with silver plus yttrium and silver, respectively. Whereas the maximum grain aspect ratio for the tapes was about 6, this value reached up to 14 for the flat wires

  6. Percolation modelling for highly aligned polycrystalline superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, N A; Glowacki, B A; Evetts, J E [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); IRC in Superconductivity, Madingley Road, Cambridge CB3 0HE (United Kingdom)

    2000-11-01

    Surface and bulk texture measurements have been carried out on highly aligned NiFe tapes, suitable for use as coated conductor substrates. Data from small-area electron backscatter diffraction measurements are compared with those from bulk x-ray analysis in the development of a two-dimensional percolation model, and the two are shown to give very similar results. No evidence of grain-to-grain correlation is found. The model is then developed to assess how the properties of a superconducting layer grown epitaxially on buffered tapes will depend on parameters such as sample size, grain size and the extent of grain alignment. (author)

  7. Introital ultrasonography in female urinary incontinence

    Energy Technology Data Exchange (ETDEWEB)

    Weon, Young Cheol; Cho, Kyoung Sik; Lee, Jin Seong; Choi, Sang Hee; Kim, Keon Seok; Choo, Myung Soo [Ulsan Univ. Asan Medical Center, Seoul (Korea, Republic of)

    1996-06-01

    To evaluate the usefulness of introital ultrasonography in the assessment of female urinary incontinence. Introital ultrasonography was performed in fifteen with stress urinary incontinence(mean age 50) and six patients without symptoms of incontinence(mean age 37). Using a sagittal section of the anterior pelvis in the plane of the symphysis pubis the posterior urethrovesical angle, the pubourethral distance and the pubo-yregrak abgle were measured at rest and during stress(Valsalva's maneuver state). The student T-test and the ANOVA test were used in statistical analysis. The posterior urethrovesical angles of the controls were 125.3 deg ({+-}10.9) at rest and 125.7 deg ({+-}7.6) during stress. In the patients, the corresponding angles were 135.3 deg ({+-}11.3) and 139.6 deg({+-}10.8). The posterior urethrovesical angles increased 0.3 deg ({+-}4.7) in the controls and 5.6 deg ({+-}4.0) in the patients(p=0.018). In the controls, the pubo-urethral distances were 21.8 mm({+-}5.8) at rest and 18.2 mm({+-}7.1) during stress, while in the patients these distances were 18.4 mm({+-}3.9) and 12.6 mm({+-}4.4). The pubo-urethral distance decreased 3.5 mm ({+-}1.5) in the controls and 5.8 mm ({+-}2.3) in the patients(p=0.039). In the patients with mild incontinence(Grade I), the posterior urethrovesical angles increased 3.4 deg ({+-}2.8) : 132.3 deg ({+-}12.5) at rest and 135.6 deg (12.8) during stress. In the patients with moderate incontinence(Grade II), the angles increased 8.1 deg({+-}3.8) : 136.0 deg({+-}6.5) at rest and 144.1 deg({+-}5.9) during stress. The change of the posterior urethrovesical angle was related to the grade of urinary incontinence in the patients(p<0.05). There was no statistical significancy in the pubo-urethral angle (p=0.315). Introital ultrasonography may be useful for assessment of stress urinary incontinence.

  8. Dorsal free graft urethroplasty for urethral stricture by ventral sagittal urethrotomy approach.

    Science.gov (United States)

    Asopa, H S; Garg, M; Singhal, G G; Singh, L; Asopa, J; Nischal, A

    2001-11-01

    To explore the feasibility of applying a dorsal free graft to treat urethral stricture by the ventral sagittal urethrotomy approach without mobilizing the urethra. Twelve patients with long or multiple strictures of the anterior urethra were treated by a dorsal free full-thickness preputial or buccal mucosa graft. The urethra was not separated from the corporal bodies and was opened in the midline over the stricture. The floor of the urethra was incised, and an elliptical raw area was created over the tunica on which a free full-thickness graft of preputial or buccal mucosa was secured. The urethra was retubularized in one stage. After a follow-up of 8 to 40 months, one recurrence developed and required dilation. The ventral sagittal urethrotomy approach for dorsal free graft urethroplasty is not only feasible and successful, but is easy to perform.

  9. WAVELET ANALYSIS AND NEURAL NETWORK CLASSIFIERS TO DETECT MID-SAGITTAL SECTIONS FOR NUCHAL TRANSLUCENCY MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Giuseppa Sciortino

    2016-04-01

    Full Text Available We propose a methodology to support the physician in the automatic identification of mid-sagittal sections of the fetus in ultrasound videos acquired during the first trimester of pregnancy. A good mid-sagittal section is a key requirement to make the correct measurement of nuchal translucency which is one of the main marker for screening of chromosomal defects such as trisomy 13, 18 and 21. NT measurement is beyond the scope of this article. The proposed methodology is mainly based on wavelet analysis and neural network classifiers to detect the jawbone and on radial symmetry analysis to detect the choroid plexus. Those steps allow to identify the frames which represent correct mid-sagittal sections to be processed. The performance of the proposed methodology was analyzed on 3000 random frames uniformly extracted from 10 real clinical ultrasound videos. With respect to a ground-truth provided by an expert physician, we obtained a true positive, a true negative and a balanced accuracy equal to 87.26%, 94.98% and 91.12% respectively.

  10. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  11. Properties of hot pressed MgB2/Ti tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Melisek, T.; Fedor, J.; Cambel, V.; Morawski, A.; Kario, A.

    2009-01-01

    Hot axial and hot isostatic pressing was applied for single-core MgB 2 /Ti tapes. Differences in transport current density, n-exponents and critical current anisotropy are discussed and related to the grain connectivity influenced by pressing. The magnetic Hall probe scanning measurements allowed observing the isolated regions for axially hot pressed sample attributed to the longitudinally oriented cracks introduced by pressing. The highest current densities were measured for the tape subjected to hot isostatic pressing due to improved connectivity.

  12. Thermal conductivity measurement of HTS tapes and stacks for current lead applications

    International Nuclear Information System (INIS)

    Schwarz, Michael; Weiss, Klaus-Peter; Heller, Reinhard; Fietz, Walter H.

    2009-01-01

    The use of high-temperature-superconductors (HTS) within current leads offers a high potential to save cooling-power. The principle of HTS current leads is well established, e.g. for particle accelerators (LHC-CERN) but also on the commercial sector, which offer HTS current leads ready for use in small scale magnets and magnets systems. Future fusion machines currently under construction like ITER, W7-X or JT-60SA also will use HTS current leads. At the moment the standard material for HTS current leads is a Bi 2 Sr 2 Ca 2 Cu 3 O x (BSCCO)-AgAu composite tape. The common way to receive high current capacity current leads is to form stacks by sintering or soldering these tapes together. The solder changes the thermal conductivity of the stacks compared to the single tape in the temperature range from 4 K to 60 K. To estimate the heat flux from the warm environment to the cold application the measurement of the thermal conductivity of the soldered stack is mandatory. Therefore the thermal conductivity of stacks with different number of tapes is investigated. To measure the thermal conduction in the current flow direction, the axial heat flow method is used. Combining these results with FEM simulations gives the possibility to estimate the thermal conductivity normal to the flat tape plane. The resulting anisotropic thermal conductivity can be used to model the behaviour of the HTS tape under thermal disturbances more accurately.

  13. High rate of vaginal erosions associated with the mentor ObTape.

    Science.gov (United States)

    Yamada, Brian S; Govier, Fred E; Stefanovic, Ksenija B; Kobashi, Kathleen C

    2006-08-01

    The transobturator tape method is a newer surgical technique for the treatment of stress urinary incontinence. Limited data exist related to complications with this approach or the types of mesh products used. We report our experience with vaginal erosions associated with the Mentor ObTape and American Medical Systems Monarc transobturator slings. Beginning in December 2003 selected female patients with anatomic urinary incontinence were prospectively followed after placement of the Mentor ObTape. Beginning in January 2004 we also began using the American Medical Systems Monarc in similar patients. Patients were admitted overnight after surgery, discharged on oral antibiotics, and seen in the clinic at 6 weeks postoperatively. A total of 67 patients have undergone placement of the Mentor ObTape and 9 of those patients (13.4%) have had vaginal extrusions of the sling. Eight patients reported a history of persistent vaginal discharge. One patient presented initially to an outside facility with a left thigh abscess tracking to the left inguinal incision site. Each patient was taken back to the operating room for mesh removal. A total of 56 patients have undergone placement of the AMS Monarc and none have had any vaginal erosions. Our high rate of vaginal extrusion using the ObTape has led us to discontinue the use of this product in our institution. Continued followup of all of these patients will be of critical importance.

  14. Multi-Response Parameter Interval Sensitivity and Optimization for the Composite Tape Winding Process

    Science.gov (United States)

    Yu, Tao; Kang, Chao; Zhao, Pan

    2018-01-01

    The composite tape winding process, which utilizes a tape winding machine and prepreg tapes, provides a promising way to improve the quality of composite products. Nevertheless, the process parameters of composite tape winding have crucial effects on the tensile strength and void content, which are closely related to the performances of the winding products. In this article, two different object values of winding products, including mechanical performance (tensile strength) and a physical property (void content), were respectively calculated. Thereafter, the paper presents an integrated methodology by combining multi-parameter relative sensitivity analysis and single-parameter sensitivity analysis to obtain the optimal intervals of the composite tape winding process. First, the global multi-parameter sensitivity analysis method was applied to investigate the sensitivity of each parameter in the tape winding processing. Then, the local single-parameter sensitivity analysis method was employed to calculate the sensitivity of a single parameter within the corresponding range. Finally, the stability and instability ranges of each parameter were distinguished. Meanwhile, the authors optimized the process parameter ranges and provided comprehensive optimized intervals of the winding parameters. The verification test validated that the optimized intervals of the process parameters were reliable and stable for winding products manufacturing. PMID:29385048

  15. CORRELATION BETWEEN CERVICAL SAGITTAL ALIGNMENT AND FUNCTIONAL CAPACITY IN CERVICAL SPONDYLOSIS

    Directory of Open Access Journals (Sweden)

    Marcel Machado da Motta

    Full Text Available ABSTRACT Objective: To correlate the radiographic parameters of sagittal cervical alignment with quality of life and functional capacity in patients with cervical spondylosis under conservative treatment. Methods: This is an observational and prospective study in patients with cervical spondylosis under conservative treatment and without indication for surgery. The 52 patients included were divided into three groups: axial pain, radiculopathy, and cervical myelopathy. The radiographic parameters considered were cervical lordosis (CL, cervical sagittal vertical axis (CSVA, T1 slope (TS and the discrepancy between TS and CL (TS-CL. Quality of life and functional capacity were evaluated by the Neck Disability Index (NDI questionnaire. Pain was assessed by the Visual Analogue Scale (VAS. The correlation between the radiographic parameters and the clinical scores was evaluated by the Pearson correlations coefficient. Results: There was no difference in cervical radiographic parameters between the three groups. In the total of the sample, the mean value of the CSVA was 17.8o (±8.3o, CL, 22.4° (± 8.8°; TS, 29.3° (±6.6°, and TS-CL, 7.0° (±7.4°. Significant inverse correlation (r= -0.3, p=0.039 was observed between NDI and CL, but there was no significant correlation between CL and VAS. CSVA (p=0.541, TS (p=0.287 and TS-CL (p=0.287 had no significantly correlated with NDI or VAS. Conclusion: Considering patients with cervical spondylosis not candidates for surgery, the only sagittal parameter that correlated with functional capacity was LC. In these patients, the correlation between cervical alignment and quality of life needs to be better characterized.

  16. [Evaluation of the clinical results of non-surgical treatment for pediatric sagittal fracture of mandibular condyle].

    Science.gov (United States)

    Liu, Chang-kui; Tan, Xin-ying; Xu, Juan; Liu, Hua-wei; Liu, San-xia; Hu, Min

    2013-11-01

    To investigate the clinical results of occlusal splint in the treatment of sagittal fracture of mandibular condyle (SFMC) in children. Thirty-nine patients (48 condyles)aged 3-8 years with sagittal fracture of mandibular condyle were included in this study. All the patients were treated by occlusal splint.Slight open occlusion was maintained by occlusal splint for 3-6 months. Clinical and radiological examination was performed six mouths and every year after treatment. Good mandibular function was observed in 39 patients. Maximal mouth opening over 35 mm was achieved at 6 months. But 11 of the 39 patients presented with deviation on mouth opening at 6 months. The radiology showed an complete remodeling in 32 condyles (28 patients) and partial remodeling in 16 condyles (11 patients). Poor remodelling was not observed in any patients. Good clinical results can be obtained by using occlusal splint in the treatment of pediatric sagittal fracture of mandibular condyle.

  17. A rare complication in a child undergoing chemotherapy for acute lymphoblastic leukemia: Superior sagittal sinus thrombosis

    Directory of Open Access Journals (Sweden)

    Ting-Yao Wang

    2011-04-01

    Full Text Available We report the case of a 4-year-old boy with acute lymphoblastic leukemia in high-risk group who suffered from generalized tonic-colonic seizure evolving into status epilepticus, and subsequent left hemiparesis during his first reinduction chemotherapy, consisting of dexamethasone, vincristine, l-asparaginase, and epirubicin. Superior sagittal sinus and cerebral venous thrombosis, predominantly in right side, were proved by brain magnetic resonance imaging. After aggressive treatment with low-molecular weight heparin (LMWH, left hemiparesis improved in 1 week. And he was fully ambulatory 3 weeks later. The second cycle of reinduction chemotherapy was conducted smoothly with the concomitant use of LMWH. This case illustrates the strong correlation of the rare thrombotic complication, superior sagittal sinus thrombosis, and hypercoagulable status secondary to combination use of l-asparaginase and corticosteroid. Early and vigilant recognition of superior sagittal sinus thrombosis and prompt anticoagulation with LMWH may prevent further neurological damage.

  18. A comparison of economy and sagittal plane trunk movements among back-, back/front- and head-loading.

    Science.gov (United States)

    Hudson, Sean; Cooke, Carlton; Davies, Simeon; West, Sacha; Gamieldien, Raeeq; Low, Chris; Lloyd, Ray

    2018-05-14

    It has been suggested that freedom of movement in the trunk could influence load carriage economy. This study aimed to compare the economy and sagittal plane trunk movements associated with three load carriage methods that constrain posture differently. Eighteen females walked at 3 km.h -1 with loads of 0, 3, 6, 9, 12, 15 and 20 kg carried on the back, back/front and head. Load carriage economy was assessed using the Extra Load Index (ELI). Change in sagittal plane trunk forward lean and trunk angle excursion from unloaded to loaded walking were assessed. Results show no difference in economy between methods (p = 0.483), despite differences in the change in trunk forward lean (p = 0.001) and trunk angle excursion (p = 0.021) from unloaded to loaded walking. We conclude that economy is not different among the three methods of load carriage, despite significant differences in sagittal plane trunk movements.

  19. Conductive sub-layer of twisted-tape-induced swirl-flow heat transfer in vertical circular tubes with various twisted-tape inserts

    Science.gov (United States)

    Hata, K.; Fukuda, K.; Masuzaki, S.

    2018-04-01

    Twisted-tape-induced swirl-flow heat transfer due to exponentially increasing heat inputs with various exponential periods ( Q = Q 0 exp(t/τ), τ = 6.04 to 23.07 s) and twisted-tape-induced pressure drop was systematically measured for various mass velocities ( G = 4115 to 13,656 kg/m2 s), inlet liquid temperatures ( T in = 285.88 to 299.09 K), and inlet pressures ( P in = 847.45 to 943.29 kPa) using an experimental water loop flow. Measurements were made over a 59.2-mm effective length and three sections (upper, middle, and lower positions), within which four potential taps were spot-welded onto the outer surface of a 6-mm-inner-diameter, 69.6-mm-heated length, 0.4-mm-thickness platinum circular test tube. Type SUS304 twisted tapes with a width w = 5.6 mm, a thickness δ T = 0.6 mm, a total length l = 372 mm, and twist ratios y = 2.39 and 4.45 were employed in this study. The RANS equations (Reynolds Averaged Navier-Stokes Simulation) with a k-ɛ turbulence model for a circular tube 6 mm in diameter and 636 mm in length were numerically solved for heating of water with a heated section 6 mm in diameter and 70 mm in length using the CFD code, under the same conditions as the experimental ones and considering the temperature dependence of the thermo-physical properties concerned. The theoretical values of surface heat flux q on the circular tubes with twisted tapes with twist ratios y of 2.39 and 4.45 were found to be almost in agreement with the corresponding experimental values of heat flux q, with deviations of less than 30% for the range of temperature difference between the average heater inner surface temperature and the liquid bulk mean temperature ΔT L [ = T s,av - T L , T L = ( T in + T out )/2] considered in this study. The theoretical values of the local surface temperature T s , local average liquid temperature T f,av , and local liquid pressure drop ΔP x were found to be within almost 15% of the corresponding experimental ones. The thickness of the

  20. Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?

    OpenAIRE

    Yang, Jae-Man; Lee, Jung-Hoon

    2018-01-01

    Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin ...

  1. Risk factors affecting somatosensory function after sagittal split osteotomy

    DEFF Research Database (Denmark)

    Thygesen, Torben Henrik; Jensen, Allan Bardow; Helleberg, M

    2008-01-01

    Purpose The aim of this study was to evaluate potential individual and intraoperative risk factors associated with bilateral sagittal split osteotomy (BSSO) and to correlate the findings with postoperative changes in somatosensory function. Patients and Methods A total of 18 men and 29 women (mean...... and free dissection of the inferior alveolar nerve during BSSO increased self-reported changes in lower lip sensation and lower lip tactile threshold after BSSO (P discrimination (P

  2. Optimal compliance for amblyopia therapy: occlusion with a translucent tape on the lens.

    Science.gov (United States)

    Beneish, Raquel G; Polomeno, Robert C; Flanders, Michael E; Koenekoop, Robert K

    2009-10-01

    To demonstrate that optimal compliance to amblyopia therapy and a better visual outcome can be achieved by occluding the lens over the preferred eye with a translucent tape. Prospective study of amblyopic children. Eighty-four amblyopic children recruited from 2000 to 2006 at the Montreal Children's Vision Centre. A group of bilateral ametropes (mean age 3.8 years) were treated with glasses and occlusion of the sound eye with a translucent tape on the lens over the preferred eye, or an adhesive patch. The translucent tape reduced vision to hand motion at 0.3 m in the sound eye. Patients were divided into 2 groups depending on the treatment received. Group 1 (n = 36) was occluded with a translucent tape, and group 2 (n = 48) with a conventional adhesive patch, later replaced by the translucent tape. Twenty-five previously reported patients, treated with the conventional adhesive patch only, were used as controls (group 3). The mean amblyopic visual acuity was 20/100-2. Compliance was good in 36 patients (group 1), and was poor or deteriorated in 24/48 patients (group 2). Substituting the adhesive patch with a translucent tape permitted uninterrupted and prolonged occlusion, with a successful visual outcome. The amblyopic eye achieved a significantly better final vision (20/30+2; groups 1+2) than the controls (20/40+1; group 3) (p = 0.04). Sixty-four (76.19%) patients achieved >or=20/30. The translucent tape optimizes compliance and yields better vision by lengthening the duration of occlusion therapy and reducing the number of treatment failures due to noncompliance.

  3. Use of nitrogen cryogun for separating duct tape and recovery of latent fingerprints with a powder suspension method.

    Science.gov (United States)

    Bailey, James A; Crane, Jonathan Stuart

    2011-07-15

    Duct tape is sometimes recovered as physical evidence in crimes. The purpose of this study was to determine the quality of latent prints on the adhesive and non-adhesive surfaces of duct tape samples that were separated using three methods. Three hundred donor fingerprint impressions were deposited on duct tape. Sections of duct tape were affixed to sections of cardboard and a fingerprint placed on the non-adhesive surface of the tape. A second layer of duct tape was prepared and a fingerprint placed on the adhesive side of the tape and then the tape was affixed to the piece of tape on the cardboard. After a 24-h period, the samples were separated using gradual force, liquid nitrogen applied with a cryogun and an adhesive neutralizer to separate the layers of tape. The recovered fingerprints were processed with a fingerprint powder suspension method. The recovered fingerprint images were evaluated and rated as +1, +2, or +3. The liquid nitrogen spray separation method yielded the highest number of +3 prints. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. "Space slitter" for film or tape

    Science.gov (United States)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  5. Quantitative analysis of the effects of strain-state on the microstructure and Jc of BSCCO tapes

    International Nuclear Information System (INIS)

    Blumenthal, W.R.; Zhu, Y.T.; Sebring, R.J.; Lowe, T.C.; Asaro, R.J.

    1996-01-01

    After considerable optimization efforts, conventional thermomechanical processing of long, high temperature superconductors has not produced critical current densities (J c ) adequate for most liquid nitrogen temperature applications. New approaches are needed to improve the J c of superconducting tape produced by co-deforming a ductile silver sheath containing the superconducting oxide using the powder-in-tube process. This study investigates improvements in J c generated by modifying the strain-state during rolling of silver-sheathed Bi 2 Sr 2 Ca 2 Cu 3 O 10+x (BSCCO-2223) tape using quantitative image analysis of the different phases. Pure compression and combined compression-shear loading was achieved by embedding BSCCO-2223 tapes at different locations within thick steel blocks. High hydrostatic compressive stress was imposed by confining the tape width. Tapes deformed with combined shear-compression exhibited measurably higher J c values than tapes subjected to pure compression, but their microstructures showed little difference in the amount of nonconducting (including porosity) phase content. However, constraining the tape width resulted in the most significant increase in J c which corresponded to a much lower porosity and nonconducting phase volume in the oxide near the tape edge

  6. Normal anatomy of the female pelvis in axial, coronal, and sagittal planes demonstrated with reformatted CT

    International Nuclear Information System (INIS)

    Constant, O.C.; Cooke, J.C.; Parsons, C.A.

    1987-01-01

    Axial CT is used in assessing gynecologic malignancies. Accurate delineation of local tumor extent in carcinoma of the cervix is important in initial staging and in planning subsequent management. A modified scanning technique produces reformatted coronal and sagittal images, which demonstrate additional valuable information about the cardinal ligaments, parametria, ureters, boundaries between the cervix, bladder, and rectum, and extension to vagina and uterus. This information is illustrated by representative axial, coronal, and sagittal scans. Familiarity with normal appearances is essential to allow correct interpretation of pathology

  7. Ipsilateral wrist-ankle movements in the sagittal plane encoded in extrinsic reference frame.

    Science.gov (United States)

    Muraoka, Tetsuro; Ishida, Yuki; Obu, Takashi; Crawshaw, Larry; Kanosue, Kazuyuki

    2013-04-01

    When performing oscillatory movements of two joints in the sagittal plane, there is a directional constraint for performing such movements. Previous studies could not distinguish whether the directional constraint reflected movement direction encoded in the extrinsic (outside the body) reference frame or in the intrinsic (the participants' torso/head) reference frame since participants performed coordinated movements in a sitting position where the torso/head was stationary relative to the external world. In order to discern the reference frame in the present study, participants performed paced oscillatory movements of the ipsilateral wrist and ankle in the sagittal plane in a standing position so that the torso/head moved relative to the external world. The coordinated movements were performed in one of two modes of coordination, moving the hand upward concomitant with either ankle plantarflexion or ankle dorsiflexion. The same directional mode relative to extrinsic space was more stable and accurate as compared with the opposite directional mode. When forearm position was changed from the pronated position to the supinated position, similar results were obtained, indicating that the results were independent of a particular coupling of muscles. These findings suggest that the directional constraint on ipsilateral joints movements in the sagittal plane reflects movement direction encoded in the extrinsic reference frame. Copyright © 2013 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.

  8. Influence of bress laminate volume fraction on electromechanical properties of externally laminated coated conductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay M.; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Lee, Jae Hun; Lee, Hun Ju; Moon, Seung Hyun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-09-15

    The enhancement of mechanical properties of coated conductor (CC) tapes in practical application are usually achieved by reinforcing through lamination or electroplating metal layers on either sides of the CC tape. Mechanical or electromechanical properties of the CC tapes have been largely affected by the lamination structure under various loading modes such as tension, bending or even cyclic. In this study, the influence of brass laminate volume fraction on electromechanical properties of RCE-DR processed Gadolinium-barium-copper-oxide (GdBCO) CC tapes was investigated. The samples used were composed of single-side and both-side laminate of brass layer to the Cu-stabilized CC tape and their Ic behaviors were compared to those of the Cu-stabilized CC tape without external lamination. The stress/strain dependences of Ic in laminated CC tapes under uniaxial tension were analyzed and the irreversible stress/strain limits were determined. As a result, the increase of brass laminate volume fraction initially increased the irreversible strain limit and became gradual. The corresponding irreversible stress limit, however, showed no difference even though the brass laminate volume fraction increased to 3.4. But the irreversible load limit linearly increased with the brass laminate volume fraction.

  9. A new concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1981-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 mm wide recording tape 116 m long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation. (orig.)

  10. Is Postoperative Intensive Care Unit Care Necessary following Cranial Vault Remodeling for Sagittal Synostosis?

    Science.gov (United States)

    Wolfswinkel, Erik M; Howell, Lori K; Fahradyan, Artur; Azadgoli, Beina; McComb, J Gordon; Urata, Mark M

    2017-12-01

    Of U.S. craniofacial and neurosurgeons, 94 percent routinely admit patients to the intensive care unit following cranial vault remodeling for correction of sagittal synostosis. This study aims to examine the outcomes and cost of direct ward admission following primary cranial vault remodeling for sagittal synostosis. An institutional review board-approved retrospective review was undertaken of the records of all patients who underwent primary cranial vault remodeling for isolated sagittal craniosynostosis from 2009 to 2015 at a single pediatric hospital. Patient demographics, perioperative course, and outcomes were recorded. One hundred ten patients met inclusion criteria with absence of other major medical problems. Average age at operation was 6.7 months, with a mean follow-up of 19.8 months. Ninety-eight patients (89 percent) were admitted to a general ward for postoperative care, whereas the remaining 12 (11 percent) were admitted to the intensive care unit for preoperative or perioperative concerns. Among ward-admitted patients, there were four (3.6 percent) minor complications; however, there were no major adverse events, with none necessitating intensive care unit transfers from the ward and no mortalities. Average hospital stay was 3.7 days. The institution's financial difference in cost of intensive care unit stay versus ward bed was $5520 on average per bed per day. Omitting just one intensive care unit postoperative day stay for this patient cohort would reduce projected health care costs by a total of $540,960 for the study period. Despite the common practice of postoperative admission to the intensive care unit following cranial vault remodeling for sagittal craniosynostosis, the authors suggest that postoperative care be considered on an individual basis, with only a small percentage requiring a higher level of care. Therapeutic, III.

  11. Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-03-01

    Full Text Available Questions: Is Kinesio Taping more effective than a sham taping/placebo, no treatment or other interventions in people with musculoskeletal conditions? Is the addition of Kinesio Taping to other interventions more effective than other interventions alone in people with musculoskeletal conditions? Design: Systematic review of randomised trials. Participants: People with musculoskeletal conditions. Intervention: Kinesio Taping was compared with sham taping/placebo, no treatment, exercises, manual therapy and conventional physiotherapy. Outcome measures: Pain intensity, disability, quality of life, return to work, and global impression of recovery. Results: Twelve randomised trials involving 495 participants were included in the review. The effectiveness of the Kinesio Taping was tested in participants with: shoulder pain in two trials; knee pain in three trials; chronic low back pain in two trials; neck pain in three trials; plantar fasciitis in one trial; and multiple musculoskeletal conditions in one trial. The methodological quality of eligible trials was moderate, with a mean of 6.1 points on the 10-point PEDro Scale score. Overall, Kinesio Taping was no better than sham taping/placebo and active comparison groups. In all comparisons where Kinesio Taping was better than an active or a sham control group, the effect sizes were small and probably not clinically significant or the trials were of low quality. Conclusion: This review provides the most updated evidence on the effectiveness of the Kinesio Taping for musculoskeletal conditions. The current evidence does not support the use of this intervention in these clinical populations. PROSPERO registration: CRD42012003436. [Parreira PdCS, Costa LdCM, Hespanhol Junior LC, Lopes AD, Costa LOP (2014 Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review. Journal of Physiotherapy 60: 31–39

  12. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    International Nuclear Information System (INIS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-01-01

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  13. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Yang, Xinsheng, E-mail: xsyang@swjtu.edu.cn [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Zhao, Yong [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Superconductivity Research Group, School of Materials Science and Engineering, University of New South Wale, Sydney 2052, NSW (Australia)

    2015-12-15

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  14. Cost, operation and hospitalization times in distraction osteogenesis versus sagittal split osteotomy

    NARCIS (Netherlands)

    van Strijen, P. J.; Breuning, K. H.; Becking, A. G.; Perdijk, F. B. T.; Tuinzing, D. B.

    2003-01-01

    Distraction osteogenesis in 'common' surgical orthodontics is mentioned as an alternative for conventional sagittal split osteotomy. After a 'learning curve' in the surgical skills of distraction, the two techniques can be compared concerning time and cost aspects. Forty-seven patients (male n=28,

  15. Laser-assisted patterning of double-sided adhesive tapes for optofluidic chip integration

    Science.gov (United States)

    Zamora, Vanessa; Janeczka, Christian; Arndt-Staufenbiel, Norbert; Havlik, George; Queisser, Marco; Schröder, Henning

    2018-02-01

    Portable high-sensitivity biosensors exhibit a growing demand in healthcare, food industry and environmental monitoring sectors. Optical biosensors based on photonic integration platforms are attractive candidates due to their high sensitivity, compactness and multiplexing capabilities. However, they need a low-cost and reliable integration with the microfluidic system. Laser-micropatterned double-sided biocompatible adhesive tapes are promising bonding layers for hybrid integration of an optofluidic biochip. As a part of the EU-PHOCNOSIS project, double-sided adhesive tapes have been proposed to integrate the polymer microfluidic system with the optical integrated waveguide sensor chip. Here the adhesive tape should be patterned in a micrometer scale in order to create an interaction between the sample that flows through the polymer microchannel and the photonic sensing microstructure. Three laser-assisted structuring methods are investigated to transfer microchannel patterns to the adhesive tape. The test structure design consists of a single channel with 400 μm wide, 30 mm length and two circular receivers with 3 mm radius. The best structuring results are found by using the picosecond UV laser where smooth and straight channel cross-sections are obtained. Such patterned tapes are used to bond blank polymer substrates to blank silicon substrates. As a proof of concept, the hybrid integration is tested using colored DI-water. Structuring tests related to the reduction of channel widths are also considered in this work. The use of this technique enables a simple and rapid manufacturing of narrow channels (50-60 μm in width) in adhesive tapes, achieving a cheap and stable integration of the optofluidic biochip.

  16. A Review Of Referral Patterns For Sagittal Synostosis In Ireland: 2008-2013

    LENUS (Irish Health Repository)

    Berney, M J

    2018-01-01

    Sagittal synostosis (SS) is the commonest form of craniosynostosis. Children with sagittal synostosis in Ireland are treated in the National Paediatric Craniofacial Centre (NPCC) in Temple Street Children’s University Hospital. This retrospective study analysed the correlation between referral patterns to the unit and age at operation. The notes of 81 patients referred over a 5 year period (April 2008 – April 2013) to the NPCC with non-syndromic SS were reviewed and demographics and referral information were recorded. Of 81 patients reviewed, 60 (74%) were referred before 6 months of age, while 21 (26%) had late referrals. Neonatologists referred 100% of infants before 6 months, paediatricians referred 71%, and GPs 64%. Later referral was associated with a more complex referral pathway, including multiple-steps of referral and unnecessary investigations. Improved clinician knowledge and emphasis on the importance of early referral may lead to a reduction in late referrals.

  17. Comparison of Broselow tape measurements versus mother estimations of pediatric weights

    Directory of Open Access Journals (Sweden)

    Sherafat Akaberian

    2013-06-01

    Full Text Available Background Pediatric resuscitation is challenging for therapeutic group. The most physicians have limited experience in dealing with this situation. Appropriate dosing of the drugs depends on the body weight of the children that it is usually not feasible. There is need for a fast, convenient and reliable method for body weight estimation in children. The aim of this study was to assess the accuracy of Broselow tape in children of Bushehr city. Material and Methods: This cross-sectional study was conducted in the emergency department of Aliasghar hospital. Children were between 1 month and 14 years. Children with chronic disease, 334, ill children were excluded from study. Estimated weight measured based on Broselow tape and actual weight measured by digital scale, then estimated and actual weight were compared. The results were analyzed by SPSS Software Ver 18 and T-Test, Chi-Square Test. Results: findings showed that 43.2% of total subjects were female Mean of age were 43 months. 72.5% of tape body weights were within  10% error of actual body weights. 78.9% of tape body weight was within  15% error of actual body weights. There was no significant difference between boys and girls. Conclusion: Broslow tape was easy, fast and exact for body weight estimation in emergency situation .it is more exact of body weight estimation by parents or therapeutic group so it helps therapeutic group in emergency department for accounting of medication dosage and equipment sizes.

  18. Effect of athletic taping and kinesiotaping® on measurements of functional performance in basketball players with chronic inversion ankle sprains.

    Science.gov (United States)

    Bicici, Seda; Karatas, Nihan; Baltaci, Gul

    2012-04-01

    Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Crossover Study Design Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased performance. (Standing heel rise test: Athletic taping

  19. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    Science.gov (United States)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape

  20. Increase of horizontal stiffness for fixing mobile machine with vacuum pad by using filament tapes

    Science.gov (United States)

    Kim, H.-S.; Park, J.-K.; Ro, S.-K.

    2017-08-01

    This paper presents a method to increase fixing stiffness of mobile machine by using filament tapes. Mobile machine moves on a large workpiece for cutting, drilling, welding, and cleaning, etc., so for those works. The vacuum pads are generally used for attaching or detaching objects frequently. Of course, if the object is a metal body, the magnetic force can be used. The vacuum pads have an advantage that it can be used regardless of the magnetic property of the object, but it has a disadvantage that the fixing stiffness is not strong because the material is rubber. That’s why it is difficult to maintain the accurate position of the mobile machine as it could be shaken when being moved or fixed. Thus, this study proposed a method to increase the horizontal fixing stiffness of the mobile machine by using filament tapes to the side of the vacuum pads which compensate the shortcoming of the vacuum pads. Filament tapes are made by inserting special material filaments which have high rigidity into an existing tape to increase tensile strength. In the configuration of the proposed method, the vacuum pad forms the vertical fixing stiffness by suction force, and the filament tape forms the horizontal fixing stiffness by adhesive force. In order to verify the effectiveness of the proposed method, the experimental equipment to measure the fixing stiffness was fabricated, and the comparison experiment was carried out. First, the horizontal fixing stiffness of the vacuum pads and the filament tape was measured respectively as a baseline data, and then the same measurement of the combination of them was performed for the comparison. In addition, another experiment for comparison between Gecko films and filament tape was performed. The results showed that the horizontal fixing stiffness was significantly increased when the filament tape was used together with the vacuum pads, and the Gecko film was not as much effective as the filament tape in terms of the strength of the

  1. The Variation of Interface Formation with Slurry Viscosity Change in Side-By-Side Tape Casting

    DEFF Research Database (Denmark)

    Bulatova, Regina; Jabbari, Masoud; Andersen, Kjeld Bøhm

    Homogenous and flexible adjacently graded tapes were produced by casting the organic-based slurries simultaneously. To develop side-by-side tape casing (SBSTC), the material optimization, modernization of the doctor blade design, and parameters control of such processes as casting, drying, de......-bindering and sintering were studied. Solvent and binder concentrations were varied in order to optimize co-casting flow, as well as the drying and sintering shrinkage. Tapes were evaluated in terms of rheological behavior of the slurries, the green and sintered tape microstructure, the quality of the interface area...

  2. Research and development efforts relative to superconducting materials. Final report. [Nb/sub 3/Sn tapes

    Energy Technology Data Exchange (ETDEWEB)

    Adam, E; Beishcher, P; Marancik, W; Lucariello, R; Young, M

    1976-04-01

    Three processes for the production of low-loss superconducting tapes of Nb/sub 3/Sn were investigated. They are the rolled-bronze process, the electron beam (EB) bronze deposition process, and the high-rate sputtering process. Shortly after the start of the investigation, effort on the last two processes was suspended because the process-development time that would be needed to arrive at a suitable transmission-line tape appeared most likely to be the shortest with the rolled-bronze process. Long lengths of Nb/sub 3/Sn tapes were prepared by the rolled-bronze process from extruded and rolled bronze-clad niobium billets. Tapes were stabilized by removing the bronze layer after reaction and then coating the exposed Nb/sub 3/Sn with high-purity copper by EB evaporation. Several meters of high quality Nb/sub 3/Sn tapes were produced by the rolled-bronze process. Even when the tapes were stabilized with copper, the losses were as low as 1.8 ..mu..W/cm/sup 2/ at 4.2 K and a surface current density of 500 rms A/cm. Despite early curtailment of the effort on the EB bronze-deposition process, short samples of Nb/sub 3/Sn tapes were produced.

  3. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    Science.gov (United States)

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  4. The effect of kinesio taping in forward bending of the lumbar spine.

    Science.gov (United States)

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C; Barbosa, Aurélio de Melo

    2014-09-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping(®) technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping(®) influenced fascia mobility, allowing for slight improvement of lumbar flexibility.

  5. Zebrin II Is Expressed in Sagittal Stripes in the Cerebellum of Dragon Lizards (Ctenophorus sp.).

    Science.gov (United States)

    Wylie, Douglas R; Hoops, Daniel; Aspden, Joel W; Iwaniuk, Andrew N

    2016-01-01

    Aldolase C, also known as zebrin II (ZII), is a glycolytic enzyme that is expressed in cerebellar Purkinje cells of the vertebrate cerebellum. In both mammals and birds, ZII is expressed heterogeneously, such that there are sagittal stripes of Purkinje cells with high ZII expression (ZII+) alternating with stripes of Purkinje cells with little or no expression (ZII-). In contrast, in snakes and turtles, ZII is not expressed heterogeneously; rather all Purkinje cells are ZII+. Here, we examined the expression of ZII in the cerebellum of lizards to elucidate the evolutionary origins of ZII stripes in Sauropsida. We focused on the central netted dragon (Ctenophorus nuchalis) but also examined cerebellar ZII expression in 5 other dragon species (Ctenophorus spp.). In contrast to what has been observed in snakes and turtles, we found that in these lizards, ZII is heterogeneously expressed. In the posterior part of the cerebellum, on each side of the midline, there were 3 sagittal stripes consisting of Purkinje cells with high ZII expression (ZII+) alternating with 2 sagittal stripes with weaker ZII expression (ZIIw). More anteriorly, most of the Purkinje cells were ZII+, except laterally, where the Purkinje cells did not express ZII (ZII-). Finally, all Purkinje cells in the auricle (flocculus) were ZII-. Overall, the parasagittal heterogeneous expression of ZII in the cerebellum of lizards is similar to that in mammals and birds, and contrasts with the homogenous ZII+ expression seen in snakes and turtles. We suggest that a sagittal heterogeneous expression of ZII represents the ancestral condition in stem reptiles which was lost in snakes and turtles. © 2017 S. Karger AG, Basel.

  6. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    Science.gov (United States)

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  7. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    Science.gov (United States)

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  8. Computer tape library for collective dose assessments in the European Community

    International Nuclear Information System (INIS)

    Jones, J.A.; Kelly, G.N.

    1981-01-01

    A computer tape library has been established which can readily be applied to enable calculations to be made of the collective dose to the population of the European Community from radioactive effluent discharges within the EC. The background to the development of the tape library and details of its contents, method of application and availability are summarised in this note. (author)

  9. Development of a test procedure for cryogenic adhesive tapes; Entwicklung einer Testprozedur fuer kryogene Klebebaender

    Energy Technology Data Exchange (ETDEWEB)

    Funke, Thomas; Haberstroh, Christoph [TU Dresden (Germany). Bitzer-Professur fuer Kaelte-, Kryo- und Kompressorentechnik; Mayrhofer, Robert; Stipsitz, Johannes [RUAG Space GmbH, Wien (Austria)

    2016-07-01

    At cryostats and dewars for lowest temperatures - especially in connection with liquid-helium cooling at around 4 K, as well at the most applications of the superconductivity - often joints and shutters on the base of low-temperature suited adhesive tapes are required. A current method for the thermal isolation of cold surfaces is their covering with highly reflecting aluminium foils, which are fastened by adhesive aluminium tapes. Selection, usage, and reliability estimation of presumably suited adhesive tapes respectively aluminium tapes occurs presently rather heuristically. A corresponding testing apparature for the measurement of the maximal pulling force was developed and tested by means of a series of test measurements. The testing set-up and measurement results for the validation of the measurement concept with adhesive aluminium tapes are presented in this contribution.

  10. Uranium doping and neutron irradiation of Bi-2223 superconduction tapes for improved critical current density

    International Nuclear Information System (INIS)

    Moss, S.D.; Wang, W.G.; Dou, S.X.; Weinstein, R.

    1998-01-01

    It is demonstrated that a combination of neutron irradiation with uranium doping introduce fission tracks through a Bi-2223 tape which act as effective pinning centres, leading to a substantial increase in critical current. Preliminary data suggests that the combination of uranium doping and neutron irradiation produces improved flux pinning in Bi-2223 tapes over neutron irradiation alone. Before irradiation, SEM, DTA and XRD analyses were performed on the tapes. Both before and after irradiation the trapped maximum magnetic flux was measured at 77K. Before neutron irradiation, uranium doping has no effect on critical current. Preliminary SEM data suggested that the uranium is homogeneously distributed throughout the oxide core of the tape. The presence of 2212 and other secondary phases in the doped tapes suggest further refinement of the sintering procedure is necessary. (authors)

  11. Characteristics of joint resistance with different kinds of HTS tapes for heater trigger switch

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Je Yull; Park, Young Gun; Lee, Woo Seung; Jo, Hyun Chul; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of); Yoon, Yong Soo [Shin Ansan University, Ansan (Korea, Republic of)

    2014-03-15

    Recently, many researches on the system of superconducting power supply and superconducting magnetic energy storage (SMES) using high temperature superconducting (HTS) tapes has been progressed. Those kinds of superconducting devices use the heater trigger switches that have a control delay problem at moments of heating up and cooling down. One way to reduce the time delay is using a different HTS tape at trigger part. For example, HTS tape having lower critical temperature can reduce time delay of heating up and heating down stage for heater trigger operation. This paper deals with resistances joint with different kinds of HTS tapes which have different properties to verify usefulness of the suggested method. Three kinds of commercial HTS tapes with different specifications are selected as samples and two kinds of solders are used for comparison. Joint is performed with temperature and pressure controllable joint machine and the joint characteristics are analyzed under the repeatable conditions.

  12. Comparing the Effectiveness of Sagittal Balance, Foraminal Stenosis, and Preoperative Cord Rotation in Predicting Postoperative C5 Palsy.

    Science.gov (United States)

    Chugh, Arunit J S; Weinberg, Douglas S; Alonso, Fernando; Eubanks, Jason D

    2017-11-01

    Retrospective cohort review. To determine whether preoperative cord rotation is independently correlated with C5 palsy when analyzed alongside measures of sagittal balance and foraminal stenosis. Postoperative C5 palsy is a well-documented complication of cervical procedures with a prevalence of 4%-8%. Recent studies have shown a correlation with preoperative spinal cord rotation. There have been few studies, however, that have examined the role of sagittal balance and foraminal stenosis in the development of C5 palsy. A total of 77 patients who underwent cervical decompression-10 of whom developed C5 palsy-were reviewed. Sagittal balance was assessed using curvature angle and curvature index on radiographs and magnetic resonance image (MRI). Cord rotation was assessed on axial MRI. C4-C5 foraminal stenosis was assessed on sagittal MRI using area measurements and a grading scale. Demographics and information on surgical approach were gathered from chart review. Correlation with C5 palsy was performed by point-biserial, χ, and regression analyses. Point-biserial analysis indicated that only cord rotation showed significance (Pbalance did not correlate with presence of C5 palsy. Logistic regression model yielded cord rotation as the only significant independent predictor of C5 palsy. For every degree of axial cord rotation, the likelihood ratio for suffering a C5 palsy was 3.93 (95% confidence interval, 2.01-8.66; Ppoints to mechanisms other than direct compression as the etiology. In addition, the lack of correlation with postoperative changes in sagittal balance hints that measures of curvature angle and curvature index may not be appropriate to accurately predict this complication. Level 3.

  13. 'Twisted tape sign': Its significance in recurrent sigmoid volvulus

    International Nuclear Information System (INIS)

    Gopal, K.; Lim, Y.; Banerjee, B.

    2005-01-01

    Aim: Sigmoid volvulus is a common cause of intestinal obstruction in the elderly. Mild attacks of sigmoid volvulus may be more difficult to diagnose due to the lack of severity of symptoms which may resolve spontaneously only to recur after an interval. This study was a review of patients to assess the incidence of the 'twisted tape sign' and to evaluate the significance of its presence in cases of recurrent sigmoid volvulus. Methods and materials: A retrospective study over eight years revealed six cases of surgically confirmed recurrent sigmoid volvulus. Case records and barium enemas of all patients were reviewed. Results: Six patients were identified, including four men and two women, with a median age of 56 years. Diagnostic difficulties were encountered in four (67%) patients with a delay ranging between 10 and 37 months with a mean 17.3 months. Twisted tape sign was confirmed on all barium examinations retrospectively. Conclusion: Recognition of twisted tape sign on barium enema examination along with an appropriate clinical history would suggest a diagnosis of recurrent sigmoid volvulus

  14. Design and Test of a Thermal Triggered Persistent Current System using High Temperature Superconducting Tapes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Keun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Kang, Hyoungku [Electro-Mechanical Research Institute, Hyundai Heavy Industries, Yongin (Korea, Republic of); Ahn, Min Cheol [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yang, Seong Eun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yoon, Yong Soo [Department of Electrical Engineering, Ansan College of Technology, 671 Choji-Dong, Danwon-Gu, Ansan, 425-792 (Korea, Republic of); Lee, Sang Jin [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Ko, Tae Kuk [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of)

    2006-06-01

    A superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as high uniformity of magnetic field and reduced thermal loss. A high temperature superconducting (HTS) persistent current switch (PCS) system was designed and tested in this research. The HTS PCS was optimally designed using two different HTS tapes, second generation coated conductor (CC) HTS tape and Bi-2223 HTS tape by the finite element method (FEM) in thermal quench characteristic view. The CC tape is more prospective applicable wire in these days for its high n value and critical current independency from external magnetic field than Bi-2223 tape. Also a prototype PCS system using Bi-2223 tape was manufactured and tested. The PCS system consists of a PCS part, a heater which induces the PCS to quench, and a superconducting magnet. The test was performed in various conditions of transport current. An initial current decay appeared when the superconducting magnet was energized in a PCS system was analyzed. This paper would be foundation of HTS PCS researches.

  15. Sun StorageTek T9940 Tape Drive

    CERN Multimedia

    2002-01-01

    Technology allowed reuse of the same data cartridge at higher capacity with later model of the tape drive hence offering significant savings of the media cost. It has been use by the CERN from 2002 to 2008.

  16. Sagittal reconstruction computed tomography in metrizamide cisternography. Useful diagnostic procedure for malformations in craniovertebral junction and posterior fossa

    Energy Technology Data Exchange (ETDEWEB)

    Mochizuki, H.; Okita, N.; Fujii, T.; Yoshioka, M.; Saito, H. (Tohoku Univ., Sendai (Japan). School of Medicine)

    1982-08-01

    We studied the sagittal reconstruction technique in computed tomography with metrizamide. Ten ml of metrizamide, 170 mg iodine/ml in concentration, were injected by lumbar puncture. After diffusion of the injected metrizamide, axial computed tomograms were taken by thin slice width (5 mm) with overlapped technique. Then electrical sagittal reconstruction was carried out by optioned software. Injection of metrizamide, non-ionic water soluble contrast media, made clear contrasts among bone, brain parenchyma and cerebrospinal fluid with computed tomography. Sagittal reconstruction technique could reveal more precise details and accurate anatomical relations than ordinary axial computed tomography. This technique was applied on 3 cases (Arnold-Chiari malformation, large cisterna magna and partial agenesis cerebellar vermis), which demonstrated a useful diagnostic procedure for abnormalities of craniovertebral junction and posterior fossa. The adverse reactions of metrizamide were negligible in our series.

  17. Comparison study of cable geometries and superconducting tape layouts for high-temperature superconductor cables

    Science.gov (United States)

    Ta, Wurui; Shao, Tianchong; Gao, Yuanwen

    2018-04-01

    High-temperature superconductor (HTS) rare-earth-barium-copper-oxide (REBCO) tapes are very promising for use in high-current cables. The cable geometry and the layout of the superconducting tapes are directly related to the performance of the HTS cable. In this paper, we use numerical methods to perform a comparison study of multiple-stage twisted stacked-tape cable (TSTC) conductors to find better cable structures that can both improve the critical current and minimize the alternating current (AC) losses of the cable. The sub-cable geometry is designed to have a stair-step shape. Three superconducting tape layouts are chosen and their transport performance and AC losses are evaluated. The magnetic field and current density profiles of the cables are obtained. The results show that arrangement of the superconducting tapes from the interior towards the exterior of the cable based on their critical current values in descending order can enhance the cable's transport capacity while significantly reducing the AC losses. These results imply that cable transport capacity improvements can be achieved by arranging the superconducting tapes in a manner consistent with the electromagnetic field distribution. Through comparison of the critical currents and AC losses of four types of HTS cables, we determine the best structural choice among these cables.

  18. Progress in Jc and magnetic field performance of Bi-2223/Ag composite tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Katsaros, A.; Reilly, D.; Thorley, A.; Herrmann, J.

    1998-01-01

    Full text: The application of high-temperature superconductors to electric power systems is actively pursued by several commercial teams around the world. A promising candidate is the Bi-2223/Ag composite superconductor. For large scale commercial applications the conductor must meet certain engineering specifications including high current capacity in the presence of a self-generated magnetic field ranging from a few hundred mT in transmission cables to 1-2 T in transformers and current limiters, and to much higher fields in the case of superconducting coils for energy storage and magnets. In the last two years, a commercial consortium consisting of Metal Manufactures Ltd, University of Wollongong and CSIRO has focused on the development of Bi-2223/Ag composite tape suitable for use in electric power applications. The powder-in-tube process is used to produce conventional single filament and multifilament tapes and twisted conductors. An appropriate measure of 'process capability' is routine running of the process and evaluation of tape performance. In this paper we report on the electrical properties of Bi-2223/Ag composite tapes produced as part of the long-length product development. The transport critical current density of tapes is measured in magnetic fields up to 9 T (H parallel and H perpendicular tape-plane) and as a function of temperature (4 - 80 K). Transport ac losses are determined at 77 K and 60 Hz, and the bend strain performance is determined at 77 K for strains up to 1.5 %

  19. Automatic storage of single gamma spectra on magnetic tape. Programs Longo, Dire

    International Nuclear Information System (INIS)

    Los Arcos Merino, J.M.

    1978-01-01

    The program Longo provides the block size and the black number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a Multi-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program Dire has been written to transform the single gamma spectra into a new Fastrand disk file, storing the information in 36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then availables by standard Fortran V reading sentences. (author)

  20. Automatic storing of single gamma spectra on magnetic tape. Programs LONGO, DIRE

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.

    1978-01-01

    The program LONGO provides the block size and the block number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a MULTI-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program DIRE has been written to transform the single gamma spectra into a new FASTRAND disk file, storing the information in-36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then available by standard FORTRAN V reading sentences. (Author) 3 refs

  1. Performance Assessment in a Heat Exchanger Tube with Opposite/Parallel Wing Twisted Tapes

    Directory of Open Access Journals (Sweden)

    S. Eiamsa-ard

    2015-02-01

    Full Text Available The thermohydraulic performance in a tube containing a modified twisted tape with alternate-axes and wing arrangements is reported. This work aims to investigate the effects of wing arrangements (opposite (O and parallel (P wings at different wing shapes (triangle (Tri, rectangular (Rec, and trapezoidal (Tra wings and on the thermohydraulic performance characteristics. The obtained results show that wing twisted tapes with all wing shape arrangements (O-Tri/O-Rec/O-Tra/P-Tri/P-Rec/P-Tra give superior thermohydraulic performance and heat transfer rate to the typical twisted tape. In addition, the tapes with opposite wing arrangement of O-Tra, O-Rec, and O-Tri give superior thermohydraulic performances to those with parallel wing arrangement of P-Tra, P-Rec, and P-Tri around 2.7%, 3.5%, and 3.2%, respectively.

  2. Current distribution and enhancement of the engineering critical current density in multifilament Bi-2223 tapes

    DEFF Research Database (Denmark)

    Wang, W.G.; Jensen, M.B.; Kindl, B.

    2000-01-01

    The spatial distribution of the critical current density (Jc) and engineering critical current density (Je) along the tape width direction was studied by a cutting technique on Bi-2223 multifilamentary tapes. In general, an increase of Jc towards the centre of the tape was measured. We attribute...... microstructure with a great amount of secondary phases. Local variation of Jc was measured within the centre segment of the tape. This indicates the influence of other factors on Jc, such as filament shape, connectivity of the filaments, and sausaging. Enhancement of Je has been pursued in which average Je of 12...

  3. Numerical Analysis of Heat transfer Enhancement in a double pipe heat exchanger with a holed twisted tape

    Directory of Open Access Journals (Sweden)

    Kumar Akarsh

    2018-01-01

    Full Text Available In the present study numerical analysis of enhancement in heat transfer characteristics in a double pipe heat exchanger is studied using a holed twisted tape.The twisted tape with a constant twist ratio is inserted in a double pipe heat exchanger. Holes of diameter 1mm, 3 mm and 5 mm were drilled at regular pitch throughout the length of the tape. Numerical modeling of a double pipe heat exchanger with the holed twisted tape was constructed considering hot fluid flowing in the inner pipe and cold fluid through the annulus.Simulation was done for varied mass flow rates of hot fluid in the turbulent condition keeping the mass flow rate of cold fluid being constant. Thermal properties like Outlet temperatures, Nusselt number, overall heat transfer coefficient, heat transfer rate and pressure drop were determined for all the cases. Results indicated that normaltwisted tape without holes performed better than the bare tube. In the tested range of mass flow rates the average Nusselt number and heat transfer rate were increased by 85% and 34% respectively. Performance of Twisted tape with holes was slightly reduced than the normal twisted tape and it deteriorated further for higher values hole diameter. Pressure drop was found to be higher for the holed twisted tape than the normal tape.

  4. SUPLEMENTASI Lactobacillus acidophilus SNP-2 PADA TAPE DAN PENGARUHNYA PADA RELAWAN [Supplementation of Lactocbacillus acidophilus SNP-2 Into Tape and its Effect to the Volunteer

    Directory of Open Access Journals (Sweden)

    Endang S Rahayu1

    2004-08-01

    Full Text Available Functional food is defined as any potentially healthful food or food ingredient that may provide a health benefit beyond the traditional nutrients it contains. Many researches have been conducted on the health benefit of probiotic (life bacterial cells, one of the ingredient of functional foods. One of the potential bacteria used for probiotic agent and also involved in traditional fermented foods are lactic acid bacteria (LAB. Previous research showed that Lactobacillus acidophilus SNP-2 isolated from faecal material of healthy infant is resistant to acid and bile salt, and has an antagonistic effect against several enteric bacterial pathogens. The objective of this research was to study the effect of L. acidophilus SNP-2 as probiotic agent to the health benefits. These bacteria were supplemented into tape ketan (fermented sticky rice, the indigenous Indonesian fermented food. Tape ketan was chosen as the carrier of probiotic biomass based on the high population of LAB in this product, i.e., 1.3 x 108 CFU/g. Addition of L. acidophilus SNP-2 biomass prior to fermentation of tape ketan resulted in a higher total of LAB cells, i.e. 2.1 x 109 CFU/g compared to the amount of 1.5 x 108 CFU/g when the addition was done after fermentation. Consumption of tape ketan containing probiotic agent by the volunteers increased the population of lactobacilli (from 1.7x107 CFU/g to 9.9x107 CFU/g and decreased the population of enterobacteriacea (from 5.4x109 CFU/g to 4.4x108 in their faecal material. This phenomenon revealed that probiotic agent was able to colonize and inhibit the growth of enterobacteriaceae in the gastrointestinal tract. The result implied that tape ketan can be used as a carrier for probiotic agent and it can be categorized as functional food

  5. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    International Nuclear Information System (INIS)

    Jabbari, M.; Bulatova, R.; Tok, A.I.Y.; Bahl, C.R.H.; Mitsoulis, E.; Hattel, J.H.

    2016-01-01

    Highlights: • Brief review of the tape casting process for ceramics. • Role of fluid flow analysis in tape casting of ceramics. • Rheological classification of common fluids in tape casting. • Review of commonly used rheological behaviour for ceramics in tape casting. - Abstract: Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casting the rheological behaviour of the slurry as well as the material flow during casting are of utmost importance since these phenomena to a large extent determine the final properties and hence the quality of the cast product. During the last decades this has led to an increasing number of works in literature within fluid flow analysis of tape casting. In the present paper a review of the development of the tape casting process with particular focus on the rheological classifications as well as modelling the material flow is hence presented and in this context the current status is examined and future potential discussed.

  6. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jabbari, M., E-mail: mjab@mek.dtu.dk [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark); Bulatova, R. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, Building 779, Roskilde (Denmark); Tok, A.I.Y. [School of Materials Science & Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Bahl, C.R.H. [Department of Energy Conversion and Storage, Technical University of Denmark, Frederiksborgvej 399, Building 779, Roskilde (Denmark); Mitsoulis, E. [School of Mining Engineering and Metallurgy, National Technical University of Athens, Zografou, 15780 Athens (Greece); Hattel, J.H. [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark)

    2016-10-15

    Highlights: • Brief review of the tape casting process for ceramics. • Role of fluid flow analysis in tape casting of ceramics. • Rheological classification of common fluids in tape casting. • Review of commonly used rheological behaviour for ceramics in tape casting. - Abstract: Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casting the rheological behaviour of the slurry as well as the material flow during casting are of utmost importance since these phenomena to a large extent determine the final properties and hence the quality of the cast product. During the last decades this has led to an increasing number of works in literature within fluid flow analysis of tape casting. In the present paper a review of the development of the tape casting process with particular focus on the rheological classifications as well as modelling the material flow is hence presented and in this context the current status is examined and future potential discussed.

  7. The effect of tape casting operational parameters on the quality of adjacently graded ceramic film

    DEFF Research Database (Denmark)

    Bulatova, Regina; Gudik-Sørensen, Mads; Della Negra, Michela

    2016-01-01

    For small length tape casting of ceramic slurries varying green film thickness is often a problem. To optimise this, the following parameters were investigated: single blade, double blade, using a pump system and a modelled speed change mode have been analysed. Advantages and limitations of every...... method are described here. The tape casting experiments were built to be generic in order to allow the control of various processing conditions. From these results, the single-blade technique was chosen for a study of side-by-side tape casting. The influence of the geometric parameters of partitioning...... the casting tank into chambers, on the quality of graded tape was studied. Tape casting experiments at different speeds and partition tongue lengths in combination with rheological tests revealed that high casting speeds and absence of the partition under the blade are detrimental to the formation...

  8. [Ultrasound in monitoring of the second stage of labour].

    Science.gov (United States)

    Fouché, C J; Simon, E G; Potin, J; Perrotin, F

    2012-11-01

    In the second stage of labor, fetal head rotation and fetal head position are determinant for the management of labor to attempt a vaginal delivery or a cesarean section. However, digital examination is highly subjective. Nowadays, delivery rooms are often equipped with compact and high performance ultrasound systems. The clinical examination can be easily completed by quantified and reproducible methods. Transabdominal ultrasonography is a well-known and efficient way to determine the fetal head position. Nevertheless, ultrasound approach to assess fetal head descent is less widespread. We can use translabial or transperineal way to evaluate fetal head position. We describe precisely two different types of methods: the linear methods (3 different types) and the angles of progression (4 different types of measurement). Among all those methods, the main pelvic landmarks are the symphysis pubis and the fetal skull. The angle of progression appears promising but the assessment was restricted to occipitoanterior fetal position cases. In the coming years, ultrasound will likely play a greater role in the management of labor. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  9. Influence of powder pre-annealing on the phase formation and critical current of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Chen, X.P.; Grivel, Jean-Claude; Li, M.Y.

    2004-01-01

    . The effects of different precursors were investigated by XRD, SEM/EDS and critical current measurements. It has been found that both the microstructure and phase formation depended strongly on the different lead-rich phases, which determined the reactivity of the precursor. Tapes fabricated using...... the precursor with Ca2PbO4 phase (tape T1) had lower transformation rate of 2223 phase than tapes fabricated using the precursor with 3321 phase (tape T2). SEM results show that a large fraction of secondary phases with big particle size was formed in the tape T1 during the subsequent sintering, which might...

  10. Surgical treatment of sagittal fracture of mandibular condyle using long-screw osteosynthesis.

    Science.gov (United States)

    Luo, Shufang; Li, Bo; Long, Xing; Deng, Mohong; Cai, Hengxing; Cheng, Yong

    2011-07-01

    The retrospective study evaluated long-screw (bicortical screw) osteosynthesis used in the surgical treatment of sagittal fracture of the mandibular condyle and compared it with titanium plates and removal of the condylar fragment. Ninety-five patients with sagittal fracture of the mandibular condyle received open surgical treatment from 1997 to 2008. Among these patients, the condylar fragments were fixed with long screws in 56 cases (group A), were fixed with titanium plates in 12 cases (group B), and were completely removed in 24 cases (group C). Follow-up was carried out clinically and radiologically. The clinical features included limitation of mandibular mobility, occlusion disturbance, lateral deviation on mouth opening, joint pain, clicking, facial asymmetry, and patient's subjective evaluation. The radiologic parameters consisted of degree of bony resorption, bony change, change of osteosynthesis material, and shortening of mandibular ramus height. Anatomic reduction and functional restoration were obtained and no severe complication was detected in group A. However, 3 of 14 patients had severe osteoarthrosis and 2 of 14 patients had ankylosis in group B. In group C 3 of 24 patients had mandibular retrusion, 4 of 24 patients had front teeth open bite, 4 of 24 patients had severe osteoarthrosis, and 1 of 24 patients had ankylosis. The long-screw fixation group had a more favorable prognosis than the titanium plate group and the group in which removal of the condylar fragment was performed. The long-screw fixation technique might be suitable for use in the surgical treatment of sagittal fractures of the mandibular condyle. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Electromechanical characterization of superconducting wires and tapes at 77 K

    CERN Document Server

    Bjoerstad, Roger

    The strain dependency of the critical current in state-of-the-art cuprate high-temperature superconductors (HTS) has been characterized. A universal test machine (UTM) combined with a critical current measurement system has been used to characterize the mechanical and the superconducting properties of conductors immersed in an open liquid nitrogen dewar. A set-up has been developed in order to perform simultaneous measurements of the superconductor lattice parameter changes, critical current, as well as the stress and strain at 77 K in self-field in a high energy synchrotron beamline. The HTS tapes and wires studied were based on YBCO, Bi-2223 and Bi-2212. The YBCO tapes were produced by SuperPower and American Superconductors (AMSC). Two types of Bi-2223 tapes, HT and G, were produced by Sumitomo Electric Industries (SEI). The Bi-2212 wires were produced by Oxford Superconducting Technology (OST) using Nexans granulate precursor, before undergoing a specialized over pressure (OP) processing and heat treatmen...

  12. Effects of differently hardened brass foil laminate on the electromechanical property of externally laminated CC tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Mean, Byoung Jean; Lee, Jae Hun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-12-15

    The mechanical properties of REBCO coated conductor (CC) wires under uniaxial tension are largely determined by the thick component layers in the architecture, namely, the substrate and the stabilizer or even the reinforcement layer. Depending on device applications of the CC tapes, it is necessary to reinforce thin metallic foils externally to one-side or both sides of the CC tapes. Due to the external reinforcement of brass foils, it was found that this could increase the reversible strain limit from the Cu-stabilized CC tapes. In this study, the effects of differently hardened brass foil laminate on the electromechanical property of CC tapes were investigated under uniaxial tension loading. The tensile strain dependence of the critical current (I{sub c}) was measured at 77 K and self-field. Depending on whether the I{sub c} of CC tapes were measured during loading or after unloading, a reversible strain (or stress) limit could be determined, respectively. The both-sides of the Cu-stabilized CC tapes were laminated with brass foils with different hardness, namely 1/4H, 1H and EH. From the obtained results, it showed that the yield strength of the brass laminated CC tapes with EH brass foil laminate was comparable to the one of the Cu-stabilized CC tape due to its large yield strength even though its large volume fraction. It was found that the brass foil with different hardness was mainly sensitive on the stress dependence of I{sub c}, but not on the strain sensitivity due to the residual strain induced in the laminated CC tapes during unloading.

  13. Teaching with MARC Tapes

    Directory of Open Access Journals (Sweden)

    Pauline Atherton

    1970-03-01

    Full Text Available A computer based laboratory for library science students to use in class assignments and for independent projects has been developed and used for one year at Syracuse University. MARC Pilot Project tapes formed the data base. Different computer programs and various samples of the MARC file (48,POO records, approx. were used for search and retrieval operations. Data bases, programs, and seven different class assignments are described and evaluated for their impact on library education in gen- eral and individual students and faculty in particular.

  14. Quality of life and objective outcome assessment in women with tape division after surgery for stress urinary incontinence.

    Directory of Open Access Journals (Sweden)

    Daniela Ulrich

    Full Text Available Midurethral tapes may cause long-term complications such as voiding dysfunction, groin pain, de novo urgency or mesh erosion, which necessitate a reoperation. There is a paucity of data regarding health related quality of life in patients undergoing tape removal. The aim of the study was to evaluate quality of life (QoL and objective outcome after midurethral tape division or excision.All patients who underwent a midurethral tape division for voiding difficulties, pain or therapy resistant de novo overactive bladder between 1999 and 2014 were invited for follow-up. A control group with a suburethral tape without division was established in a 1:2 ratio and matched for age, tape used and year of tape insertion. Patients completed the Kings´ Health Questionnaire (KHQ, Incontinence Outcome Questionnaire, Female Sexual Function Index Questionnaire and the Patient Global Impression of Improvement score.Tape division or excision was performed in 32 women. Overall, 15 (60% of 25 women who were alive were available for clinical examination and completed the questionnaires. Tape division was performed for voiding dysfunction (n = 7, overactive bladder (n = 2, mesh extrusion (n = 3 and ongoing pain (n = 3. Median time to tape division/excision was 10 months. Three women in the tape division group had undergone reoperation for stress urinary incontinence (SUI. At a median follow-up of 11 years (IQR 9-13 subjective SUI rate was 53% (8/15 women in the tape division group and 17% (5/30 in the control group (p = 0.016, with no significant differences in objective SUI rates between groups. With regard to quality of life, the study group had significantly worse scores in the SUI related domains role limitation, physical limitation, severity measures and social limitations (KHQ compared to the control group.Women needing tape division or excision have lower SUI related QoL scores compared to controls mostly because of higher subjective SUI rates.

  15. The effectiveness of Kinesio Taping on pain and disability in cervical myofascial pain syndrome

    Directory of Open Access Journals (Sweden)

    Saime Ay

    Full Text Available Abstract Objective: The aim of this study was to investigate the effectiveness of Kinesio Taping and sham Kinesio Taping on pain, pressure pain threshold, cervical range of motion, and disability in cervical myofascial pain syndrome patients (MPS. Methods: This study was designed as a randomized, double-blind placebo controlled study. Sixty-one patients with MPS were randomly assigned into two groups. Group 1 (n = 31 was treated with Kinesio Taping and group 2 (n = 30 was treated sham taping five times by intervals of 3 days for 15 days. Additionally, all patients were given neck exercise program. Patients were evaluated according to pain, pressure pain threshold, cervical range of motion and disability. Pain was assessed by using Visual Analog Scale, pressure pain threshold was measured by using an algometer, and active cervical range of motion was measured by using goniometry. Disability was assessed with the neck pain disability index disability. Measurements were taken before and after the treatment. Results: At the end of the therapy, there were statistically significant improvements on pain, pressure pain threshold, cervical range of motion, and disability (p 0.05. Conclusion: This study shows that Kinesio Taping leads to improvements on pain, pressure pain threshold and cervical range of motion, but not disability in short time. Therefore, Kinesio Taping can be used as an alternative therapy method in the treatment of patients with MPS.

  16. Development of synthetic simulators for endoscope-assisted repair of metopic and sagittal craniosynostosis.

    Science.gov (United States)

    Eastwood, Kyle W; Bodani, Vivek P; Haji, Faizal A; Looi, Thomas; Naguib, Hani E; Drake, James M

    2018-06-01

    OBJECTIVE Endoscope-assisted repair of craniosynostosis is a safe and efficacious alternative to open techniques. However, this procedure is challenging to learn, and there is significant variation in both its execution and outcomes. Surgical simulators may allow trainees to learn and practice this procedure prior to operating on an actual patient. The purpose of this study was to develop a realistic, relatively inexpensive simulator for endoscope-assisted repair of metopic and sagittal craniosynostosis and to evaluate the models' fidelity and teaching content. METHODS Two separate, 3D-printed, plastic powder-based replica skulls exhibiting metopic (age 1 month) and sagittal (age 2 months) craniosynostosis were developed. These models were made into consumable skull "cartridges" that insert into a reusable base resembling an infant's head. Each cartridge consists of a multilayer scalp (skin, subcutaneous fat, galea, and periosteum); cranial bones with accurate landmarks; and the dura mater. Data related to model construction, use, and cost were collected. Eleven novice surgeons (residents), 9 experienced surgeons (fellows), and 5 expert surgeons (attendings) performed a simulated metopic and sagittal craniosynostosis repair using a neuroendoscope, high-speed drill, rongeurs, lighted retractors, and suction/irrigation. All participants completed a 13-item questionnaire (using 5-point Likert scales) to rate the realism and utility of the models for teaching endoscope-assisted strip suturectomy. RESULTS The simulators are compact, robust, and relatively inexpensive. They can be rapidly reset for repeated use and contain a minimal amount of consumable material while providing a realistic simulation experience. More than 80% of participants agreed or strongly agreed that the models' anatomical features, including surface anatomy, subgaleal and subperiosteal tissue planes, anterior fontanelle, and epidural spaces, were realistic and contained appropriate detail. More

  17. The Role of Proprioception in the Sagittal Setting of Anticipatory Postural Adjustments During Gait Initiation

    Directory of Open Access Journals (Sweden)

    Pereira Marcelo P.

    2015-12-01

    Full Text Available Purpose. Previous studies have studied the role of proprioception on the setting of anticipatory postural adjustments (APA during gait initiation. However, these studies did not investigate the role of proprioception in the sagittal APA setting. We aimed to investigate the role of proprioception manipulation to induce APA sagittal adaptations on gait initiation. Methods. Fourteen healthy adults performed gait initiation without, and with, vibration applied before movement onset, and during movement. In addition, the effects of two different vibration frequencies (80 and 120Hz were tested. Vibration was applied bilaterally on the tibialis anterior, rectus femoris and trapezius superior. The first step characteristics, ground reaction forces and CoP behaviour were assessed. Results. Vibration improved gait initiation performance regardless of the moment it was applied. CoP velocity during the initial phase of APA was increased by vibration only when it was applied before movement. When vibration was applied to disturb the movement, no effects on the CoP behaviour were observed. Manipulation of vibration frequency had no effects. Conclusions. Rather than proprioception manipulation, the results suggest that post-vibratory effects and attentional mechanisms were responsible for our results. Taken together, the results show that sagittal APA setting is robust to proprioception manipulation.

  18. Effects of Patellofemoral Taping on Patellofemoral Joint Alignment and Contact Area During Weight Bearing.

    Science.gov (United States)

    Ho, Kai-Yu; Epstein, Ryan; Garcia, Ron; Riley, Nicole; Lee, Szu-Ping

    2017-02-01

    Study Design Controlled laboratory study. Background Although it has been theorized that patellofemoral joint (PFJ) taping can correct patellar malalignment, the effects of PFJ taping techniques on patellar alignment and contact area have not yet been studied during weight bearing. Objective To examine the effects of 2 taping approaches (Kinesio and McConnell) on PFJ alignment and contact area. Methods Fourteen female subjects with patellofemoral pain and PFJ malalignment participated. Each subject underwent a pretaping magnetic resonance imaging (MRI) scan session and 2 MRI scan sessions after the application of the 2 taping techniques, which aimed to correct lateral patellar displacement. Subjects were asked to report their pain level prior to each scan session. During MRI assessment, subjects were loaded with 25% of body weight on their involved/more symptomatic leg at 0°, 20°, and 40° of knee flexion. The outcome measures included patellar lateral displacement (bisect-offset [BSO] index), mediolateral patellar tilt angle, patellar height (Insall-Salvati ratio), contact area, and pain. Patellofemoral joint alignment and contact area were compared among the 3 conditions (no tape, Kinesio, and McConnell) at 3 knee angles using a 2-factor, repeated-measures analysis of variance. Pain was compared among the 3 conditions using the Friedman test and post hoc Wilcoxon signed-rank tests. Results Our data did not reveal any significant effects of either McConnell or Kinesio taping on the BSO index, patellar tilt angle, Insall-Salvati ratio, or contact area across the 3 knee angles, whereas knee angle had a significant effect on the BSO index and contact area. A reduction in pain was observed after the application of the Kinesio taping technique. Conclusion In a weight-bearing condition, this preliminary study did not support the use of PFJ taping as a medial correction technique to alter the PFJ contact area or alignment of the patella. J Orthop Sports Phys Ther 2017

  19. Biomechanical study on the bladder neck and urethral positions: simulation of impairment of the pelvic ligaments.

    Science.gov (United States)

    Brandão, Sofia; Parente, Marco; Mascarenhas, Teresa; da Silva, Ana Rita Gomes; Ramos, Isabel; Jorge, Renato Natal

    2015-01-21

    Excessive mobility of the bladder neck and urethra are common features in stress urinary incontinence. We aimed at assessing, through computational modelling, the bladder neck position taking into account progressive impairment of the pelvic ligaments. Magnetic resonance images of a young healthy female were used to build a computational model of the pelvic cavity. Appropriate material properties and constitutive models were defined. The impairment of the ligaments was simulated by mimicking a reduction in their stiffness. For healthy ligaments, valsalva maneuver led to an increase in the α angle (between the bladder neck-symphysis pubis and the main of the symphysis) from 91.8° (at rest) to 105.7°, and 5.7 mm of bladder neck dislocation, which was similar to dynamic imaging of the same woman (α angle from 80° to 103.3°, and 5mm of bladder neck movement). For 95% impairment, they enlarged to 124.28° and 12 mm. Impairment to the pubourethral ligaments had higher effect than that of vaginal support (115° vs. 108°, and 9.1 vs. 7.3mm). Numerical simulation could predict urethral motion during valsalva maneuver, for both healthy and impaired ligaments. Results were similar to those of continent women and women with stress urinary incontinence published in the literature. Biomechanical analysis of the pubourethral ligaments complements the biomechanical study of the pelvic cavity in urinary incontinence. It may be useful in young women presenting stress urinary incontinence without imaging evidence of urethral and muscle lesions or organ descend during valsalva, and for whom fascial damage are not expected. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Low back pain during pregnancy and Kinesio tape application.

    Science.gov (United States)

    Reyhan, Aycan Çakmak; Dereli, Elif Elçin; Çolak, Tuğba Kuru

    2017-01-01

    Low back pain is a common problem during pregnancy. Although the pain usually occurs in the third trimester, it might be seen in the first trimester, too. There are various types of applications for the treatment of low back pain during pregnancy. However, there is a lack of evidence for the effectiveness of each method. If there is not an obvious deficit, bed rest, exercise, conventional physiotherapy, using protective principles for the lumbar area are recommended, since the main and the only complaint is low back pain. It is aimed in the current review to investigate the use of Kinesio tape in the low back pain seen during pregnancy and to review the literature related to this subject. There are only a few studies investigating the effect of Kinesio tape during pregnancy in the literature and they mostly did not aim to study the low back pain, further evidence and studies are needed to investigate the use of Kinesio tape for the low back pain seen during pregnancy as there is not evidence strong enough. Kinesiotape application aims to increase circulation and mobility, and regarding these gains decreased pain and increased performance are expected.

  1. Does Andrews facial analysis predict esthetic sagittal maxillary position?

    Science.gov (United States)

    Resnick, Cory M; Daniels, Kimberly M; Vlahos, Maryann

    2018-04-01

    Cephalometric analyses have limited utility in planning maxillary sagittal position for orthognathic surgery. In Six Elements of Orofacial Harmony, Andrews quantified maxillary position relative to forehead projection and angulation and proposed an ideal relationship. The purpose of this study was to investigate the ability of this technique to predict esthetic sagittal maxillary position. Survey study including a male and female with straight facial profiles, normal maxillary incisor angulations, and Angle's Class I. Maxillary position was modified on lateral photographs to create 5 images for each participant with incisor-goal anterior limit line (GALL) distances of -4, -2, 0, +2, and +4 mm. A series of health care professionals and laypeople were asked to rate each photo in order of attractiveness. A total of 100 complete responses were received. Incisor-GALL distances of +4 mm (41%) and +2 mm (40%) were most commonly considered "most esthetic" for the female volunteer (P < .001). For the male volunteer, there were 2 peak "most esthetic" responses: incisor-GALL distances of 0 mm (37%) and -4 mm (32%) (P < .001). Respondents considered maxillary incisor position 2 to 4 mm anterior to GALL most attractive in a woman and 0 to 4 mm posterior to GALL most esthetic in a man. Using these modified target distances, this analysis may be useful for orthognathic surgery planning. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Transforaminal Anterior Release for the Treatment of Fixed Sagittal Imbalance and Segmental Kyphosis, Minimum 2-Year Follow-Up Study.

    Science.gov (United States)

    Sweet, Fred A; Sweet, Andrea

    2015-09-01

    Retrospective review of prospectively accrued patient cohort. To report minimum 2 years' follow-up after a single-surgeon series of 47 consecutive patients in whom fixed sagittal imbalance or segmental kyphosis was treated with a novel unilateral transforaminal annular release. Fixed sagittal imbalance has been treated most recently with pedicle subtraction osteotomy with great success but is associated with significant blood loss and neurologic risk. Forty-seven consecutive patients with fixed sagittal imbalance (n = 29) or segmental kyphosis (n = 18) were treated by a single surgeon with a single-level transforaminal anterior release (TFAR) to effect an opening wedge correction. Sagittal and coronal correction was performed with in situ rod contouring. An interbody cage was captured in the disc space with rod compression. Radiographic and clinical outcome analysis was performed with a minimum 2-year follow-up (range 2-7.8 years). The average increase in lordosis was 36° (range 24°-56°) in the fixed sagittal deformity group. Coronal corrections averaged 34° (range 18°-48°). The average improvement in plumb line was 13.6 cm. There were four pseudarthroses, one at the TFAR. Average blood loss was 578 mL (range 200-1,200). One patient had a transient grade 4/5 anterior tibialis weakness. There were no vascular injuries or permanent neurologic deficits. There were significant improvements in the Oswestry Disability Index (p imbalance with relatively low blood loss and was found to be neurologically safe in this single-surgeon series. Therapeutic study, Level IV (case series, no control group). Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  3. Sagittal balance in scoliosis associated with Marfan syndrome: a stereoradiographic three-dimensional analysis.

    Science.gov (United States)

    Glard, Yann; Pomero, Vincent; Collignon, Patrick; Skalli, Wafa; Jouve, Jean-Luc; Bollini, Gérard

    2008-03-01

    Marfan syndrome (MFS) is a genetic disease often marked by the presence of scoliosis. There is no three-dimensional analysis of the deformity in the literature. Our aim was to determine what kind of sagittal balance defines scoliosis associated with MFS, namely a flexion deformity, as it is in scoliosis associated with Chiari I or an extension deformity, as in adolescent idiopathic scoliosis (AIS). To address this issue, we compared the presence or absence of a thoracic scoliosis with the presence or absence of a segment in extension in the thoracic spine. In our series, 30 patients diagnosed with Marfan syndrome were prospectively included. In each patient, personalized three-dimensional reconstruction from T1 to L5 of the spine was made using stereoradiography. The patients were first separated based on the presence or absence of thoracic scoliosis, in order to compare this with the presence or absence of a segment in extension in the thoracic spine. They were then classified into two groups based on the presence or absence of the segment in extension (meaning containing negative values of inter-vertebral sagittal rotation) in the thoracic spine. Among scoliotic patients with a thoracic scoliosis (17 cases), there were 13 (76.5% cases) with a segment in extension in the thoracic spine and 4 with no segment in extension. Our results showed that scoliosis associated with MFS is somehow original, demonstrating a sagittal balance in extension (as AIS) in about 80% of thoracic curves, but without this characteristic feature in about 20%.

  4. Prenatal MR imaging of Dandy-Walker complex: Midline sagittal area analysis

    International Nuclear Information System (INIS)

    Wong, Alex M.; Bilaniuk, Larissa T.; Zimmerman, Robert A.; Liu, P.L.

    2012-01-01

    Objective: To measure the mid-sagittal areas of vermis (VA) and of posterior fossa (PFA) and determine their differences among fetuses with various Dandy-Walker (DW) entities and control subjects. Methods: We reviewed data in 25 fetal patients with a MR diagnosis of DW complex including hypoplastic vermis (HV), HV with rotation (HVR), and mega cistern magna (MCM), and in 85 fetal controls with normal CNS. PFA and VA of each subject were manually traced on mid-sagittal MR images. Regarding each of VA and PFA, after age correction, we determined statistically significant differences among HVR, HV, MCM, and control groups. Results: The mean VA residue of MCM was greater than that of the control, which was in turn greater than those of HVR and HV. The mean PF residue of the control was smaller than all other groups. Conclusion: Fetuses with HVR or HV had smaller VA than fetuses with MCM or control subjects. Fetuses with MCM, HVR, or HV had larger PFA than control subjects. These results may be an early step leading to better understanding of the confusion about the PF anomalies in future.

  5. Comparing Outcomes and Cost of 3 Surgical Treatments for Sagittal Synostosis: A Retrospective Study Including Procedure-Related Cost Analysis.

    Science.gov (United States)

    Garber, Sarah T; Karsy, Michael; Kestle, John R W; Siddiqi, Faizi; Spanos, Stephen P; Riva-Cambrin, Jay

    2017-10-01

    Neurosurgical techniques for repair of sagittal synostosis include total cranial vault (TCV) reconstruction, open sagittal strip (OSS) craniectomy, and endoscopic strip (ES) craniectomy. To evaluate outcomes and cost associated with these 3 techniques. Via retrospective chart review with waiver of informed consent, the last consecutive 100 patients with sagittal synostosis who underwent each of the 3 surgical correction techniques before June 30, 2013, were identified. Clinical, operative, and process of care variables and their associated specific charges were analyzed along with overall charge. The study included 300 total patients. ES patients had fewer transfusion requirements (13% vs 83%, P cost savings compared with the TCV reconstruction. The charges were similar to those incurred with OSS craniectomy, but patients had a shorter length of stay and fewer revisions. Copyright © 2017 by the Congress of Neurological Surgeons

  6. Microstructure and superconducting properties of Bi-2223/Ag tapes fabricated in the two-step sintering process

    International Nuclear Information System (INIS)

    Lu, X.Y.; Nagata, A.; Sugawara, K.

    2008-01-01

    The microstructure and superconducting properties of Bi-2223/Ag tapes fabricated in the two-step sintering process were investigated. The tapes were then subjected to two heat treatments with an intermediate rolling. All the tapes were sintered at 835 deg. C for 24 h at initial sintering stage. A two-step sintering procedure was then used in the final sintering stage. In the first step, the tapes are sintered at 840-865 deg. C for 1 h. In the second step, they were sintered at 835 deg. C for 120 h. The results show that the first step sintering temperature has significant influence on the microstructure and the critical current density J c . The observed microstructures are consistent well with the different J c performances of the tapes first-step-sintered at different temperatures. The tape first-step-sintered at 850 deg. C, which has small secondary phases, stronger c-axis grain alignment, higher proportion of Bi-2223 phase, and no cracks, exhibits the highest J c value

  7. Short-Term Effects of Kinesio Taping on Muscle Recruitment Order During a Vertical Jump: A Pilot Study.

    Science.gov (United States)

    Mendez-Rebolledo, Guillermo; Ramirez-Campillo, Rodrigo; Guzman-Muñoz, Eduardo; Gatica-Rojas, Valeska; Dabanch-Santis, Alexis; Diaz-Valenzuela, Francisco

    2018-06-22

    Kinesio taping is commonly used in sports and rehabilitation settings with the aim of prevention and treatment of musculoskeletal injuries. However, limited evidence exists regarding the effects of 24 and 72 hours of kinesio taping on trunk and lower limb neuromuscular and kinetic performance during a vertical jump. The purpose of this study was to analyze the short-term effects of kinesio taping on height and ground reaction force during a vertical jump, in addition to trunk and lower limb muscle latency and recruitment order. Single-group pretest-posttest. University laboratory. Twelve male athletes from different sports (track and field, basketball, and soccer). They completed a single squat and countermovement jump at basal time (no kinesio taping), 24, and 72 hours of kinesio taping application on the gluteus maximus, biceps femoris, rectus femoris, gastrocnemius medialis, and longissimus. Muscle onset latencies were assessed by electromyography during a squat and countermovement jump, in addition to measurements of the jump height and normalized ground reaction force. The kinesio taping had no effect after 24 hours on either the countermovement or squat jump. However, at 72 hours, the kinesio taping increased the jump height (P = .02; d = 0.36) and normalized ground reaction force (P = .001; d = 0.45) during the countermovement jump. In addition, 72-hour kinesio taping reduced longissimus onset latency (P = .03; d = 1.34) and improved muscle recruitment order during a countermovement jump. These findings suggest that kinesio taping may improve neuromuscular and kinetic performance during a countermovement jump only after 72 hours of application on healthy and uninjured male athletes. However, no changes were observed on a squat jump. Future studies should incorporate a control group to verify kinesio taping's effects and its influence on injured athletes.

  8. Applied rolling and sensitivity of Bi(2223)/Ag tapes on Ic degradation by mechanical stress

    International Nuclear Information System (INIS)

    Kovac, P.; Bukva, P.; Husek, I.; Richens, P.E.; Jones, H.

    1999-01-01

    An experimental study of multicore Bi(2223)/Ag tapes, roll-sintered by different methods and subjected to bending and tension stresses has been performed. The tapes, of various technological histories, were bent and tensioned and subsequently the transport current was measured at each stressed state. Comparison of I c degradation curves shows that applied rolling may influence the sensitivity of Bi-2223 filaments against the mechanical stress. The existence of transverse microcracks caused by intermediate rolling leads to a higher sensitivity of the tape to bending. A lowering of critical current degradation was observed for two-axially rolled tapes having a higher filament density and better homogeneity prior to sintering treatment. (author)

  9. Functionally Graded Ceramics Fabricated with Side-by-Side Tape Casting for Use in Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina; Bahl, Christian; Andersen, Kjeld Bøhm

    2015-01-01

    Functionally graded ceramic tapes have been fabricated by a side-by-side tape casting technique. This study shows the possibility and describes the main principles of adjacent coflow of slurries resulting in formation of thin plates of graded ceramic material. Results showed that the small...... variations of solvent and binder system concentrations have a substantial effect on slurry viscosity. Varying these parameters showed that side-by-side tape casting with a well-defined interface area is possible for slurries with viscosities above 3500 mPa s at a casting shear rate of 3.3 s -1...... of developing this graded ceramic tape casting was applications of these specific magnetocaloric properties within the magnetic refrigeration technology....

  10. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    International Nuclear Information System (INIS)

    Lee, Myoung Seok; Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup; Park, Joong Shin; Jun, Jong Kwan

    2017-01-01

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP

  11. Value of sagittal color Doppler ultrasonography as a supplementary tool in the differential diagnosis of fetal cleft lip and palate

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myoung Seok [Dept. of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Cho, Jeong Yeon; Kim, Sang Youn; Kim, Seung Hyup [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Joong Shin; Jun, Jong Kwan [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2017-01-15

    The purpose of this study was to evaluate the feasibility and usefulness of sagittal color Doppler ultrasonography (CDUS) for the diagnosis of fetal cleft lip (CL) and cleft palate (CP). We performed targeted ultrasonography on 25 fetuses with CL and CP, taking coronal and axial images of the upper lip and maxillary alveolar arch in each case. The existence of defects in and malalignment of the alveolus on the axial image, hard palate defects on the midsagittal image, and flow-through defects on CDUS taken during fetal breathing or swallowing were assessed. We compared the ultrasonography findings with postnatal findings in all fetuses. Alveolar defects were detected in 16 out of 17 cases with CP and four out of eight cases with CL. Alveolar malalignment and hard palate defects were detected in 11 out of 17 cases and 14 out of 17 cases with CP, respectively, but not detected in any cases with CL. Communicating flow through the palate defect was detected in 11 out of 17 cases of CL with CP. The accuracy of detection in axial scans of an alveolar defect and malalignment was 80% and 76%, respectively. Accuracy of detection of in mid-sagittal images of hard palate defect and flow was 80% and 86%, respectively. The overall diagnostic accuracy of combined axial and sagittal images with sagittal CDUS was 92%. Sagittal CDUS of the fetal hard palate is a feasible method to directly reveal hard palate bony defects and flow through defects, which may have additional value in the differential diagnosis of fetal CL and CP.

  12. Phthalocyanine doping to improve critical current densities in MgB2 tapes

    International Nuclear Information System (INIS)

    Zhang Xianping; Ma Yanwei; Wang Dongliang; Gao Zhaoshun; Wang Lei; Qi Yanpeng; Awaji, Satoshi; Watanabe, Kazuo; Mossang, Eric

    2009-01-01

    Phthalocyanine-doped MgB 2 tapes were prepared by the in situ powder-in-tube method. The relationships between the critical current properties, crystallinity and microstructure were studied as a function of the phthalocyanine doping level. It is found that both H irr and H c2 were improved when MgB 2 samples were doped with phthalocyanine, which are mainly attributed to the effective carbon substitution and enhanced flux pinning strength caused by very fine grain sizes. Furthermore, compared to pure samples, the MgO content remained almost unchanged in all doped tapes, which is very beneficial to having better grain connectivity in MgB 2 . Significantly improved J c was obtained in the phthalocyanine-doped MgB 2 tapes, especially under high magnetic fields.

  13. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    Energy Technology Data Exchange (ETDEWEB)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z

    2004-10-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger.

  14. AC magnetic losses in Bi-2223/Ag tapes with different aspect ratios

    International Nuclear Information System (INIS)

    Fang, J.; Luo, X.M.; Chen, D.X.; Collings, E.W.; Lee, E.; Sumption, M.D.; Alamgir, A.K.M.; Yi, H.P.; Fang, J.G.; Gu, C.; Guo, S.Q.; Liu, M.L.; Xin, Y.; Han, Z.

    2004-01-01

    AC losses in multi-filamentary tapes depend on various parameters. Among them, the overall tape width and thickness are expected to have an important influence. In order to study this geometrical effect, five Bi-2223/Ag tapes with different aspect ratios from 5 to 26 have been prepared. AC losses have been measured at 77 K when a perpendicular AC magnetic field is applied. It has been found that at any frequencies the magnetic loss per cycle increases as the aspect ratio increases. For AC magnetic loss, with increasing frequency from 3 to 9000 Hz the losses as a function of frequency show a maximum if the field amplitude is much less than the full penetration field or increase continuously if the field amplitude is larger

  15. Prototype high-speed tape target transport for a laser plasma soft-x-ray projection lithography source

    International Nuclear Information System (INIS)

    Haney, S.J.; Berger, K.W.; Kubiak, G.D.; Rockett, P.D.; Hunter, J.

    1993-01-01

    A prototype high-speed tape target transport is constructed for use in a high-repetition-rate laser plasma source. To reduce plasma debris, a 1000--5000-A-thick film of target material is supported by thin Mylar tape backing. Tape is transported to the laser focal volume at a maximum velocity of 356 cm/s, a rate sufficient to accommodate laser repetition rates of 1 kHz. The transport is fully vacuum compatible and can be retracted and then isolated from the laser plasma vacuum enclosure during tape reel replacement. The operating characteristics of the transport are described

  16. Subjective alveolar nerve function after bilateral sagittal split osteotomy or distraction osteogenesis of mandible

    NARCIS (Netherlands)

    Baas, E.M.; Horsthuis, R.B.G.; de Lange, J.

    2012-01-01

    Purpose: The present retrospective cohort study compared the subjective inferior alveolar nerve (IAN) function after distraction osteogenesis (DOG) and bilateral sagittal split osteotomy (BSSO) in mandibular advancement surgery. Materials and Methods: Treatment consisted of correction of a

  17. Subjective Alveolar Nerve Function After Bilateral Sagittal Split Osteotomy or Distraction Osteogenesis of Mandible

    NARCIS (Netherlands)

    Baas, Erik M.; Horsthuis, Roy B. G.; de Lange, Jan

    2012-01-01

    Purpose: The present retrospective cohort study compared the subjective inferior alveolar nerve (IAN) function after distraction osteogenesis (DOG) and bilateral sagittal split osteotomy (BSSO) in mandibular advancement surgery. Materials and Methods: Treatment consisted of correction of a

  18. LANDSAT-D data format control book. Volume 6, appendix G: GSFC HDT-AM inventory tape (GHIT-AM)

    Science.gov (United States)

    1981-01-01

    The data format specifications of the Goddard HDT inventory tapes (GHITS), which accompany shipments of archival digital multispectral scanner image data (HDT-AM tapes), are defined. The GHIT is a nine-track, 1600-BPI tape which conforms to the ANSI standard and serves as an inventory and description of the image data included in the shipment. The archival MSS tapes (HDT-AMs) contain radiometrically corrected but geometrically uncorrected image data plus certain ancillary data necessary to perform the geometric corrections.

  19. The effectiveness of Kinesio Taping on pain and disability in cervical myofascial pain syndrome.

    Science.gov (United States)

    Ay, Saime; Konak, Hatice Ecem; Evcik, Deniz; Kibar, Sibel

    The aim of this study was to investigate the effectiveness of Kinesio Taping and sham Kinesio Taping on pain, pressure pain threshold, cervical range of motion, and disability in cervical myofascial pain syndrome patients (MPS). This study was designed as a randomized, double-blind placebo controlled study. Sixty-one patients with MPS were randomly assigned into two groups. Group 1 (n=31) was treated with Kinesio Taping and group 2 (n=30) was treated sham taping five times by intervals of 3 days for 15 days. Additionally, all patients were given neck exercise program. Patients were evaluated according to pain, pressure pain threshold, cervical range of motion and disability. Pain was assessed by using Visual Analog Scale, pressure pain threshold was measured by using an algometer, and active cervical range of motion was measured by using goniometry. Disability was assessed with the neck pain disability index disability. Measurements were taken before and after the treatment. At the end of the therapy, there were statistically significant improvements on pain, pressure pain threshold, cervical range of motion, and disability (pdisability (p>0.05). This study shows that Kinesio Taping leads to improvements on pain, pressure pain threshold and cervical range of motion, but not disability in short time. Therefore, Kinesio Taping can be used as an alternative therapy method in the treatment of patients with MPS. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  20. Eastern Baltic region vs. Western Europe: modelling age related changes in the pubic symphysis and the auricular surface.

    Science.gov (United States)

    Jatautis, Šarūnas; Jankauskas, Rimantas

    2018-02-01

    Objectives. The present study addresses the following two main questions: a) Is the pattern of skeletal ageing observed in well-known western European reference collections applicable to modern eastern Baltic populations, or are population-specific standards needed? b) What are the consequences for estimating the age-at-death distribution in the target population when differences in the estimates from reference data are not taken into account? Materials and methods. The dataset consists of a modern Lithuanian osteological reference collection, which is the only collection of this type in the eastern Baltic countries (n = 381); and two major western European reference collections, Coimbra (n = 264) and Spitalfields (n = 239). The age-related changes were evaluated using the scoring systems of Suchey-Brooks (Brooks & Suchey 1990) and Lovejoy et al. (1985), and were modelled via regression models for multinomial responses. A controlled experiment based on simulations and the Rostock Manifesto estimation protocol (Wood et al. 2002) was then carried out to assess the effect of using estimates from different reference samples and different regression models on estimates of the age-at-death distribution in the hypothetical target population. Results. The following key results were obtained in this study. a) The morphological alterations in the pubic symphysis were much faster among women than among men at comparable ages in all three reference samples. In contrast, we found no strong evidence in any of the reference samples that sex is an important factor to explain rate of changes in the auricular surface. b) The rate of ageing in the pubic symphysis seems to be similar across the three reference samples, but there is little evidence of a similar pattern in the auricular surface. That is, the estimated rate of age-related changes in the auricular surface was much faster in the LORC and the Coimbra samples than in the Spitalfields sample. c) The results of simulations

  1. Does taping in addition to physiotherapy improve the outcomes in subacromial impingement syndrome? A systematic review.

    Science.gov (United States)

    Saracoglu, Ismail; Emuk, Yusuf; Taspinar, Ferruh

    2018-04-01

    Taping is used with or without other interventions for many purposes, especially to manage pain and improve functional activity in patients with shoulder pain. The aim of this review was to determine whether any taping technique in addition to physiotherapy care is more effective than physiotherapy care alone in patients with shoulder impingement syndrome. A systematic search of Cochrane Database of Systematic Review, MEDLINE (EBSCO), Physiotherapy Evidence Database (PEDro), CINAHL (EBSCO), PUBMED, AMED, EMBASE (OVID), The Kinesio Kinesio® Taping Method, Kinesio® Tex Tape UK and International websites ( www.kinesiotaping.co.uk ; www.kinesiotaping.com ) was conducted to June 2015. The outcome measures were pain, disability, range of motion and muscle strength. As data were not suitable for meta-analysis, narrative synthesis were applied. Three randomized controlled trials and one controlled trial (135 patients) were included. The results were conflicting and weak on the effectiveness of taping as an adjunct therapy for improvement of pain, disability, range of motion and muscle strength. Clinical taping in addition to physiotherapy interventions (e.g. exercise, electrotherapy, and manual therapy) might be an optional modality for managing patients with shoulder impingement syndrome, especially for the initial stage of the treatment; however, we need further robust, placebo controlled and consistent studies to prove whether it is more effective than physiotherapy interventions without taping.

  2. Magnetic field profiles of NbTi tapes

    International Nuclear Information System (INIS)

    Migliori, A.; Taylor, R.D.; Bartlett, R.D.

    1976-01-01

    Magnetic field profile measurements were performed on stabilized NbTi tapes in zero applied field carrying large transport current densities. Field profile data were taken on large diameter superconducting sample loops at temperatures between 2 0 K and T/sub c/ (about 9.2 0 K) and several persistent currents up to I/sub c/(T), the maximum. The field profiles scaled with current, independent of temperature, at temperatures below 8.5 0 K and were well described by an elliptical shell approximation which left a current-free, field-free central region. Critical state models applied to this self-field situation proved inadequate. Complex profiles produced by trapped flux in the tape loop were described quantitatively by assuming concentric elliptical shells each with a different current density. The maximum current which could be persisted in the loop at each temperature was linear from 4 to 8.5 K. The effective resistance of the superconducting loop including its joint was less than 10 -13 ohms

  3. Nonlinear Model of Tape Wound Core Transformers

    Directory of Open Access Journals (Sweden)

    A. Vahedi

    2015-03-01

    Full Text Available Recently, tape wound cores due to their excellent magnetic properties, are widely used in different types of transformers. Performance prediction of these transformers needs an accurate model with ability to determine flux distribution within the core and magnetic loss. Spiral structure of tape wound cores affects the flux distribution and always cause complication of analysis. In this paper, a model based on reluctance networks method is presented for analysis of magnetic flux in wound cores. Using this model, distribution of longitudinal and transverse fluxes within the core can be determined. To consider the nonlinearity of the core, a dynamic hysteresis model is included in the presented model. Having flux density in different points of the core, magnetic losses can be calculated. To evaluate the validity of the model, results are compared with 2-D FEM simulations. In addition, a transformer designed for series-resonant converter and simulation results are compared with experimental measurements. Comparisons show accuracy of the model besides simplicity and fast convergence

  4. Artificial Intelligence Controls Tape-Recording Sequence

    Science.gov (United States)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  5. History and operation of INIS magnetic tape retrieval service in CSSR

    International Nuclear Information System (INIS)

    Blazek, J.

    The Nuclear Information Centre is responsible for the utilization of the INIS magnetic tape in Czechoslovakia as the country's national INIS centre. The tape has been used since 1974 for selective dissemination of information using an EC 1040 computer. Currently, users are provided with SDI searches, their copies (the so-called parasite searches) and retrospective searches. The organization of INIS-SDI services is described and the results are reported of the poll among the users of the services. (Ha)

  6. Analysis of transient state in HTS tapes under ripple DC load current

    Science.gov (United States)

    Stepien, M.; Grzesik, B.

    2014-05-01

    The paper concerns the analysis of transient state (quench transition) in HTS tapes loaded with the current having DC component together with a ripple component. Two shapes of the ripple were taken into account: sinusoidal and triangular. Very often HTS tape connected to a power electronic current supply (i.e. superconducting coil for SMES) that delivers DC current with ripples and it needs to be examined under such conditions. Additionally, measurements of electrical (and thermal) parameters under such ripple excitation is useful to tape characterization in broad range of load currents. The results presented in the paper were obtained using test bench which contains programmable DC supply and National Instruments data acquisition system. Voltage drops and load currents were measured vs. time. Analysis of measured parameters as a function of the current was used to tape description with quench dynamics taken into account. Results of measurements were also used to comparison with the results of numerical modelling based on FEM. Presented provisional results show possibility to use results of measurements in transient state to prepare inverse models of superconductors and their detailed numerical modelling.

  7. The evolution of the tape measure protein: units, duplications and losses

    Directory of Open Access Journals (Sweden)

    Poisson Guylaine

    2011-10-01

    Full Text Available Abstract Background A large family of viruses that infect bacteria, called phages, is characterized by long tails used to inject DNA into their victims' cells. The tape measure protein got its name because the length of the corresponding gene is proportional to the length of the phage's tail: a fact shown by actually copying or splicing out parts of DNA in exemplar species. A natural question is whether there exist units for these tape measures, and if different tape measures have different units and lengths. Such units would allow us to retrace the evolution of tape measure proteins using their duplication/loss history. The vast number of sequenced phages genomes allows us to attack this problem with a comparative genomics approach. Results Here we describe a subset of phages whose tape measure proteins contain variable numbers of an 11 amino acids sequence repeat, aligned with sequence similarity, structural properties, and simple arithmetics. This subset provides a unique opportunity for the combinatorial study of phage evolution, without the added uncertainties of multiple alignments, which are trivial in this case, or of protein functions, that are well established. We give a heuristic that reconstructs the duplication history of these sequences, using divergent strains to discriminate between mutations that occurred before and after speciation, or lineage divergence. The heuristic is based on an efficient algorithm that gives an exhaustive enumeration of all possible parsimonious reconstructions of the duplication/speciation history of a single nucleotide. Finally, we present a method that allows, when possible, to discriminate between duplication and loss events. Conclusions Establishing the evolutionary history of viruses is difficult, in part due to extensive recombinations and gene transfers, and high mutation rates that often erase detectable similarity between homologous genes. In this paper, we introduce new tools to address this

  8. Simulation of YBCO Tape and Coils in HTS Maglev System

    Directory of Open Access Journals (Sweden)

    Song Mengxiao

    2017-01-01

    Full Text Available In the process of running high temperature superconducting maglev train, the AC(Alternating Current loss of superconducting coil is directly related to its safe operation and operating cost. In this paper, the simulation model was built based on the finite element software COMSOL Multiphysics, and mainly simulated and calculated the AC losses of YBCO(Yttrium Barium Copper Oxide tape and coils. In this model, as the solving object, the singular and infinite long YBCO tape and coils model was solved with H-formulation and the nonlinear characteristic (E-J constitutive law and anisotrophy (B-J characteristic were taken into consideration as the theoretical foundation. Then on the basis of the model under maglev suspension system, AC losses under different amplitude and frequence AC currents were calculated. The results shows that under different frequencies and dynamic components, the local maximum AC loss of YBCO tape and coils occurs when the steady-state DC(Direct Current current is 30A. Then comparing with old maglev suspension system, the new system can greatly reduce the energy consumption and the material cost.

  9. Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

    International Nuclear Information System (INIS)

    Tomita, M; Suzuki, K; Fukumoto, Y; Ishihara, A; Akasaka, T; Kobayashi, Y; Maeda, A; Takayasu, M

    2015-01-01

    A 2 m length Twisted Stacked-Tape Cable (TSTC) conductor which was fabricated by 32-YBCO-tapes (4 mm width) with a 200 mm twist pitch was investigated at various temperatures near 77 K in subcooled- and pressurized-liquid nitrogen. The critical current of the TSTC cable which was 1.45 kA at 77 K measured from 64 K to 85 K by controlling the equilibrium vapor pressure of nitrogen bath and were varied from 3.65 kA at 64 K to 0.42 kA at 85 K. The temperature dependence of cables’ critical current agrees with that of the 4 mm width YBCO tape. These results are encouraging for applications of a compact Twisted Stacked-Tape Cable application in railway systems. (paper)

  10. Fabrication and Characterization of Graded Anodes for Anode-Supported Solid Oxide Fuel Cells by Tape Casting and Lamination

    DEFF Research Database (Denmark)

    Beltran-Lopez, J.F.; Laguna-Bercero, M.A.; Gurauskis, Jonas

    2014-01-01

    Graded anodes for anode-supported solid oxide fuel cells (SOFCs) are fabricated by tape casting and subsequent cold lamination of plates using different compositions. Rheological parameters are adjusted to obtain stable suspensions for tape casting. The conditions for the tape casting and laminat......Graded anodes for anode-supported solid oxide fuel cells (SOFCs) are fabricated by tape casting and subsequent cold lamination of plates using different compositions. Rheological parameters are adjusted to obtain stable suspensions for tape casting. The conditions for the tape casting...... and lamination will be described. Flexural strength of the reduced cermets measured using three-point bending configuration is 468±37MPa. The graded anode supports are characterized by scanning electron microscope observations, mercury porosimetry intrusion, and resistivity measurements, showing an adequate...... of tapes at room temperature without using plasticizers. This is made by the combination of two different binders with varying Tg (glass transition temperature) which resulted in plastic deformation at room temperature. Those results indicate that the proposed process is a cost-effective method...

  11. Study of the inhomogeneity of critical current under in-situ tensile stress for YBCO tape

    Science.gov (United States)

    Zhu, Y. P.; Chen, W.; Zhang, H. Y.; Liu, L. Y.; Pan, X. F.; Yang, X. S.; Zhao, Y.

    2018-07-01

    A Hall sensor system was used to measure the local critical current of YBCO tape with high spatial resolution under in-situ tensile stress. The hot spot generation and minimum quench energy of YBCO tape, which depended on the local critical current, was calculated through the thermoelectric coupling model. With the increase in tensile stress, the cracks which have different dimensions and critical current degradation arose more frequently and lowered the thermal stability of the YBCO tape.

  12. Field mapping measurements to determine spatial and field dependence of critical current density in YBCO tapes

    International Nuclear Information System (INIS)

    Leclerc, J.; Berger, K.; Douine, B.; Lévêque, J.

    2013-01-01

    Highlights: • A method for characterizing superconducting tapes from field mapping is presented. • A new and efficient field mapping apparatus has been setup. • This method allows the spatial characterization of superconducting tapes. • The critical current density is obtained as a function of the flux density. • This method has been experimentally tested on an YBCO tape. -- Abstract: In this paper a measurement method that allows the determination of the critical current density of superconducting tape from field mapping measurements is presented. This contact-free method allows obtaining characteristics of the superconductor as a function of the position and of the applied flux density. With some modifications, this technique can be used for reel-to-reel measurements. The determination of the critical current density is based on an inverse calculation. This involves calculating the current distribution in the tape from magnetic measurements. An YBaCuO tape has been characterized at 77 K. A defect in this superconductor has been identified. Various tests were carried out to check the efficiency of the method. The inverse calculation was tested theoretically and experimentally. Comparison with a transport current measurement was also performed

  13. BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Thomas, E-mail: thbaum@gmx.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Mueller, Dirk, E-mail: dirk.mueller@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Dobritz, Martin, E-mail: dobritz@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Rummeny, Ernst J., E-mail: institut@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Link, Thomas M., E-mail: thomas.link@radiology.ucsf.edu [Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, San Francisco, CA 94107 (United States); Bauer, Jan S., E-mail: jsb@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany)

    2011-11-15

    Purpose: To assess QCT equivalent BMD of the lumbar spine in sagittal reformations of routine abdominal contrast-enhanced MDCT with simple PACS measurement tools and to apply this method to MDCT datasets for differentiating patients with and without osteoporotic vertebral fractures. Materials and methods: Eight postmenopausal women (65 {+-} 5years) underwent standard QCT to assess BMD of L1-L3. Afterwards routine abdominal contrast-enhanced MDCT images of these women were obtained and apparent BMD of L1-L3 was measured using the sagittal reformations. The MDCT-to-QCT conversion equation for BMD was calculated with linear regression analysis. The conversion equation was applied to vertebral BMD datasets (L1-L3) of 75 postmenopausal women (66 {+-} 4years). Seventeen of the 75 patients had osteoporotic vertebral fractures. Results: BMD values of contrast-enhanced MDCT were on average 56 mg/ml higher than those of standard QCT. A correlation coefficient of r = 0.94 (p < 0.05) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMD{sub QCT} = 0.69 x BMD{sub MDCT} - 11 mg/ml. Accordingly converted BMD values of patients with vertebral fractures were significantly lower than those of patients without vertebral fractures (69 mg/ml vs. 85 mg/ml; p < 0.05). Using ROC analysis to differentiate patients with and without vertebral fractures, AUC = 0.72 was obtained for converted BMD values (p < 0.05). Short- and long-term reproducibility errors for BMD measurements in the sagittal reformations amounted 2.09% and 7.70%, respectively. Conclusion: BMD measurements of the spine could be computed in sagittal reformations of routine abdominal contrast-enhanced MDCT with minimal technical and time effort. Using the conversion equation, the acquired BMD data could differentiate patients with and without osteoporotic vertebral fractures.

  14. Chronic vaginal discharge and left leg edema after a transobturator tape procedure.

    Science.gov (United States)

    Kim, Tae-Hee; Lee, Hae-Hyeog; Kim, Jun-Mo

    2014-05-01

    We report on a patient who underwent total vaginal hysterectomy for urinary incontinence 8 years previously with a sling operation using transobturator tape (TOT). She was admitted to our hospital after complaints of vaginal discharge, foul odor, and bleeding, left thigh pain, and edema. Magnetic resonance imaging (MRI) and computed tomography (CT) revealed a fistula tract from the vagina or urethra with remnant sling tape. We removed the remnant tape using intraoperative ultrasonography. This case exemplifies the rare occurrence of a vaginal fistula extending to the obturator, adductor, and pectineus muscles combined with myositis after TOT placement. It is important that urogynecologists recognize that TOT procedures may result in complications accompanied by common recurrent vaginal symptoms, such as vaginal odor and spotting, which can be identified by MRI or CT.

  15. Test results of fault current limiter using YBCO tapes with shunt protection

    Energy Technology Data Exchange (ETDEWEB)

    Baldan, Carlos A; Lamas, Jerika S; Shigue, Carlos Y [Escola de Engenharia de Lorena, EEL USP, Lorena - SP (Brazil); Filho, Ernesto Ruppert, E-mail: cabaldan@gmail.co [Faculdade de Engenharia Eletrica, FEEC Unicamp, Campinas - SP (Brazil)

    2010-06-01

    A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper.

  16. NdFeB thick films prepared by tape casting

    International Nuclear Information System (INIS)

    Pawlowski, B.; Schwarzer, S.; Rahmig, A.; Toepfer, J.

    2003-01-01

    NdFeB films of thickness between 100 and 800 μm were prepared by tape casting of a slurry containing 84-95 wt% of commercial NdFeB powder (MQP-B, -Q and -S). After curing the flexible green tapes at 120 deg. C non-porous magnetic films are obtained. The remanence of the films is in the range of 350-450 mT and the coercivity is between 300 and 800 kA/m depending on the type of MQP powder used. The magnetic properties of the films are discussed in relation to film composition and type of magnetic material. For MEMS applications the thick films are magnetized with a multi-pole stripe pattern with 1 mm pole pitch. The induction at the surface of the films was measured with a Hall probe and compared to theoretical calculations. The results indicate that the films are completely magnetized regardless of the film thickness. Tape-casted NdFeB thick films are promising candidates for applications in micro-systems or actuators. Miniaturization of the magnet components is one of the key issues in the development of electromagnetic micro-systems, thus creating a need for replacement of small sintered magnets by magnetic thick film components. Other applications include encoders

  17. Development of Bi-based high critical current density superconducting tapes

    International Nuclear Information System (INIS)

    Swaminathan, G.

    1995-01-01

    In order to achieve the aim of developing suitable superconducting materials the main emphasis has to be made in the following areas viz., synthesizing powders, detailed study of sintering and phase conversion process in relation to the critical current density (J c ) on pellets and optimising of tape processing parameters. The bismuth system has been found to be more favourable for making wires and tapes because of its high transition temperature, good stability, does not require oxygen on cooling and is non-toxic. These have been the most convenient properties which made the BiSCO material the most popular one

  18. The new CERN tape software - getting ready for total performance

    CERN Document Server

    Cano, E; Kruse, D F; Kotlyar, V; Côme, D

    2015-01-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  19. Role of thoracoscopy for the sagittal correction of hypokyphotic adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Ferrero, E; Pesenti, S; Blondel, B; Jouve, J L; Mazda, K; Ilharreborde, B

    2014-12-01

    Thoracic adolescent idiopathic scoliosis (AIS) curves (Lenke 1-4) are often characterized by hypokyphosis. Sagittal alignment remains challenging to correct, even with recent posterior segmental instrumentation. Some authors recommend anterior endoscopic release (AER) to reduce anterior column height, and facilitate thoracic kyphosis correction. The aim of this study was to assess the contribution of AER to sagittal correction in hypokyphotic AIS. Fifty-six hypokyphotic (T4T12<20°) AIS patients were included. In group 1 (28 patients), patients first underwent AER, followed by posterior instrumentation and correction 5-7 days later. In group 2 (28 patients), patients underwent the same posterior procedure without AER. Posterior correction was performed in all cases using posteromedial translation and hybrid constructs consisting of lumbar pedicle screws and thoracic sublaminar bands. From radiological measurements performed using low-dose EOS radiographs, the correction of thoracic kyphosis was compared between the two groups. Groups 1 and 2 were comparable regarding demographic data and preoperative thoracic kyphosis (group 1: 11.7° ± 6.9° vs group 2: 12.1° ± 6.3°, p = 0.89). Postoperative thoracic kyphosis increase averaged 18.3° ± 13.6° in group 1 and 15.2° ± 9.0° in group 2. The benefit of anterior release was not statistically significant (p = 0.35). Although previous studies have suggested that thoracoscopic release improved correction compared to posterior surgery alone, the current study did not confirm this finding. Moreover, results of the current series showed that no significant benefit can be expected from AER in terms of sagittal plane improvement when the posteromedial translation technique is used, even in challenging hypokyphotic patients.

  20. Delayed latency of peroneal reflex to sudden inversion with ankle taping or bracing.

    Science.gov (United States)

    Shima, N; Maeda, A; Hirohashi, K

    2005-01-01

    The purpose of the present study was to examine the effects of ankle taping and bracing based on the peroneal reflex in the hypermobile and normal ankle joints with and without history of ankle injury. Thirty-six ankle joints of 18 collegiate American football athletes with and without previous history of injury were studied. The angle of talar tilt (TT) was measured by stress radiograph for classifying normal (TT5 degrees ) ankles. They were tested with taping, bracing, and without any supports as a control. The latency of peroneus longus muscle was measured by a sudden inversion of 25 degrees using surface EMG signals. The results of the present study show no significant three-way Group (hypermobile or normal ankles) by History (previously injured or uninjured ankles) by Condition (control, taping, or bracing) interaction, while Condition main effect was significant (p0.05). In conclusion, ankle taping and bracing delayed the peroneal reflex latency not only for hypermobile ankles and/or injured ankle joints but also for intact ankle joints.

  1. Association of baseline knee sagittal dynamic joint stiffness during gait and 2-year patellofemoral cartilage damage worsening in knee osteoarthritis.

    Science.gov (United States)

    Chang, A H; Chmiel, J S; Almagor, O; Guermazi, A; Prasad, P V; Moisio, K C; Belisle, L; Zhang, Y; Hayes, K; Sharma, L

    2017-02-01

    Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs angles during the loading response phase. Knee magnetic resonance imaging (MRI) scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations (GEE). Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); body mass index (BMI) 28.4 kg/m 2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR = 5.35, 95% CI: 2.37-12.05) and any PF (OR = 2.99, 95% CI: 1.27-7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  2. Distanced Data: Transcribing Other People's Research Tapes

    Science.gov (United States)

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  3. Localized leak detection utilizing moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    Moisture sensitive tape (MST) has been used in various nuclear power plants to detect leaks in reactor piping systems. The sensor assembly consists of MST, transponder, and sensor carrier, and is installed on the exterior of thermal insulation. The components, applications, installation, and purchasing information are discussed in the paper

  4. Global analysis of sagittal spinal alignment in major deformities: correlation between lack of lumbar lordosis and flexion of the knee.

    Science.gov (United States)

    Obeid, Ibrahim; Hauger, Olivier; Aunoble, Stéphane; Bourghli, Anouar; Pellet, Nicolas; Vital, Jean-Marc

    2011-09-01

    It has become well recognised that sagittal balance of the spine is the result of an interaction between the spine and the pelvis. Knee flexion is considered to be the last compensatory mechanism in case of sagittal imbalance, but only few studies have insisted on the relationship between spino-pelvic parameters and lower extremity parameters. Correlation between the lack of lumbar lordosis and knee flexion has not yet been established. A retrospective study was carried out on 28 patients with major spinal deformities. The EOS system was used to measure spinal and pelvic parameters and the knee flexion angle; the lack of lumbar lordosis was calculated after prediction of lumbar lordosis with two different formulas. Correlation analysis between the different measured parameters was performed. Lumbar lordosis correlated with sacral slope (r = -0.71) and moderately with knee flexion angle (r = 0.42). Pelvic tilt correlated moderately with knee flexion angle (r = 0.55). Lack of lumbar lordosis correlated best with knee flexion angle (r = 0.72 and r = 0.63 using the two formulas, respectively). Knee flexion as a compensatory mechanism to sagittal imbalance was well correlated to the lack of lordosis and, depending on the importance of the former parameter, the best procedure to correct sagittal imbalance could be chosen.

  5. Conventional Tape versus Kinesiotape for Hallux Valgus Correction

    Directory of Open Access Journals (Sweden)

    Nadia Lotfy Radwan

    2017-01-01

    Full Text Available This study was commenced to compare the effect of Kinesiotape (KT versus conventional tape (CT on HVA and IMA as well as the intensity of pain from HV deformity. Methodology: Female patients with age 45 to 60 years and diagnosed with mild to moderate HV were included in the study. The foot pain intensity was assessed by visual analogue scale (VAS before applying tape and after completion of the study. Results: The outcome measures of pain intensity showed a non-significant difference between both groups before intervention (p>0.05. Within both KT and CT groups, the pre-and post-treatment scores were significantly different (p˂0.05. In the comparison of the post treatment scores, there was a significant difference (p˂0.05 between both groups favouring the KT group..

  6. Effect of crystallization rate of initial alloy on magnetic properties of amorphous tape

    International Nuclear Information System (INIS)

    Roshchin, V.E.; Gribanov, V.P.; Shcherbakov, D.G.; Gun'kin, V.E.

    1994-01-01

    An investigation is made into mechanism and character of cooling rate effect when castings crytallizing on magnetic properties of rapidly quenched amorphous tape of Fe 78 B 12 Si 9 Ni 1 alloy. The increase of cooling rate and holding at heat for superheated melt is shown to result in a rise of Curie point of amorphous tape

  7. 10 years of 1:1 taping in Belgium - A selection of murder cases involving fibre examination.

    Science.gov (United States)

    De Wael, K; Lepot, L; Lunstroot, K; Gason, F

    2016-01-01

    Since 2002, the 1:1 tape lifting technique on murder victims has been introduced in Belgium. Thirty-six murder cases for which a fibre examination was carried out in our laboratory between 2002 and 2012 are reviewed. These cases all involved the collection of microtraces on 39 victims using a 1:1 taping or similar technique, called semi 1:1 taping. The degree of "positive outcomes" for investigative and comparative fibre cases is high. Especially in cases where the modus operandi of suspects had to be verified, the examination of the 1:1 tape lifting led to very useful fibre results. The findings from some of these fibre cases are used to illustrate the advantages, drawbacks and points of interest of the two collection techniques. These are also compared with the zonal taping technique, another microtrace collection technique applied on victims at the crime scene. Copyright © 2015 The Chartered Society of Forensic Sciences. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Effects of two different knee tape procedures on lower-limb kinematics and kinetics in recreational runners.

    Science.gov (United States)

    Howe, A; Campbell, A; Ng, L; Hall, T; Hopper, D

    2015-08-01

    The purpose of this study was to compare the effects of Mulligan's tape (MT) and kinesio tape (KT) with no tape (NT) on hip and knee kinematics and kinetics during running. Twenty-nine female recreational runners performed a series of 'run-throughs' along a 10-m runway under the three taping conditions. Two force plates and a 14-camera Vicon motion analysis system (Oxford Metrics, Inc., Oxford, UK) captured kinematic and kinetic data for each dependent variable from ground contact to toe off. Comparisons of each dependent variable under three taping conditions were assessed through Statistical Package for the Social Sciences (SPSS; SPSS, Inc., Chicago, Illinois, USA; P-value kinetics, between KT and NT (P = 1.000). MT appears to influence hip and knee biomechanics during running in an asymptomatic sample, whereas KT appeared to be biomechanically not different from NT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. An interactive tool for CT volume rendering and sagittal plane-picking of the prostate for radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Jani, Ashesh B.; Pelizzari, Charles A.; Chen, George T.Y.; Grzezcszuk, Robert P.; Vijayakumar, Srinivasan

    1997-01-01

    Objective: Accurate and precise target volume and critical structure definition is a basic necessity in radiotherapy. The prostate, particularly the apex (an important potential site of recurrence in prostate cancer patients), is a challenging structure to define using any modality, including conventional axial CT. Invasive or expensive techniques, such as retrograde urethrography or MRI, could be avoided if localization of the prostate were possible using information already available on the planning CT. Our primary objective was to build a software tool to determine whether volume rendering and sagittal plane-picking, which are CT-based, noninvasive visualization techniques, were of utility in radiotherapy treatment planning for the prostate. Methods: Using AVS (Application Visualization System) on a Silicon Graphics Indigo 2 High Impact workstation, we have developed a tool that enables the clinician to efficiently navigate a CT volume and to use volume rendering and sagittal plane-picking to better define structures at any anatomic site. We applied the tool to the specific example of the prostate to compare the two visualization techniques with the current standard of axial CT. The prostate was defined on 80-slice CT scans (scanning thickness 4mm, pixel size 2mm x 2mm) of prostate cancer patients using axial CT images, volume-rendered CT images, and sagittal plane-picked images. Results: The navigation of the prostate using the different visualization techniques qualitatively demonstrated that the sagittal plane-picked images, and even more so the volume-rendered images, revealed the prostate (particularly the lower border) better in relationship to the surrounding regional anatomy (bladder, rectum, pelvis, and penile structures) than did the axial images. A quantitative comparison of the target volumes obtained by navigating using the different visualization techniques demonstrated that, when compared to the prostate volume defined on axial CT, a larger volume

  10. Effects of scapular taping on the activity onset of scapular muscles and the scapular kinematics in volleyball players with rotator cuff tendinopathy.

    Science.gov (United States)

    Leong, Hio Teng; Ng, Gabriel Yin-Fat; Fu, Siu Ngor

    2017-06-01

    To examine the effect of scapular taping on the activity onset of scapular muscles and the scapular kinematics during arm elevation in volleyball players with rotator cuff (RC) tendinopathy. Randomized placebo-controlled repeated measures METHODS: Twenty-six male volleyball players with RC tendinopathy (mean age=23.6±3.3years) participated in the study. Electromyography (EMG) activity onset of upper trapezius (UT), middle trapezius (MT), lower trapezius (LT) and serratus anterior (SA) and the three-dimensional scapular kinematics quantified by using an acromial marker cluster method were compared with three scapular taping protocols, namely, no taping, therapeutic taping, and placebo taping. The MT, LT and SA activated significantly earlier in both therapeutic taping (all p<0.005) and placebo taping conditions than no taping conditions (all p<0.002). There was a small increase in the scapular upward rotation when therapeutic taping and no taping conditions were compared (p=0.007). Scapular taping may enhance the neuromotor control of the scapular muscles. Whether it provides adequate support for normal scapular kinematics during arm movement in athletes with RC tendinopathy await for further studies. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  11. Influence of twisted tape turbulence promoter on fouling reduction in microfiltration of milk proteins

    Directory of Open Access Journals (Sweden)

    Popović Svetlana S.

    2011-01-01

    Full Text Available Membrane filtration has become one of the major technologies in the food industry. It is widely applied in the dairy industry, and it is mostly used for the concentration and fractionation of milk proteins and for the whey processing. Of all pressure driven membrane processes, ultrafiltration is the most widely used. The major disadvantage of pressure driven membrane processes is severe fouling of membrane during filtration particularly when the fluids containing proteins are processed. Fouling with proteins is complex phenomenon because it occurs at the membrane surface as well as in the pores of membrane, and depends on the operating conditions and on the interactions of proteins and membrane material. In order to reduce fouling of the membrane different techniques have been developed, and one of them relies on the changing of the hydrodynamic conditions in the membrane or module. In this study, influence of twisted tape turbulence promoters on the fouling reduction in cross-flow microfiltration of skim milk was investigated. Twisted tapes with tree characteristic ratios of helix element length to the tape diameter (aspect ratio were studied. It was shown that twisted tapes with different aspect ratios reduce fouling of membrane by a factor of three or more. The presence of twisted tape induces changes in the flow patterns from straight to helicoidally thus producing turbulence flow at the lower cross-flow rates. Turbulence intensification prevents accumulation of proteins at membrane surface enabling reduction in reversible fouling what results in the reduction of overall membrane fouling. The best performance was achieved using a twisted tape with the lowest aspect ratio of 1.0. This promoter reduces fouling seven times at low transmembrane pressure and low cross-flow velocity. The twisted tape with aspect ratio 1.0 induces the most intensive turbulence, the longest helicoidal flow path, and appearance of vortices near the membrane surfaces

  12. Efek Interaksi Ragi Tape dan Ragi Roti terhadap Kadar Bioetanol Ketela Pohon (Manihot Utilissima, Pohl Varietas Mukibat

    Directory of Open Access Journals (Sweden)

    Tri Budi Kurniawan

    2014-09-01

    Full Text Available Ketela pohon (Manihot utilissima, Pohl varietas mukibat berpotensi sebagai bahan baku bioetanol. Penelitian bertujuan untuk mengetahui efek interaksi ragi tape dan ragi roti terhadap kadar bioetanol ketela pohon mukibat dan menentukan interaksi terendah yang efektif menghasilkan bioetanol yang dapat terbakar. Sampel yang digunakan adalah ketela pohon mukibat umur 7 bulan dengan berat rata-rata 500 gram. Penelitian menggunakan Rancangan Acak Lengkap pola faktorial, yaitu konsentrasi ragi tape (0%, 0,3%, 0,6% dan 0,9% dan konsentrasi ragi roti (0%, 0,3%, 0,6% dan 0,9% dengan 3 kali ulangan. Parameter yang diukur meliputi jumlah sel khamir (data pendukung dan kadar bioetanol (data utama. Data kadar bioetanol yang diperoleh dianalisis menggunakan anava dua arah dan dilanjutkan uji Duncan (DMRT pada taraf kesalahan 5%. Hasil penelitian menunjukkan ada pengaruh interaksi ragi tape dan ragi roti terhadap kadar bioetanol ketela pohon mukibat p>0,05. Konsentrasi ragi tape dan ragi roti yang tinggi menghasilkan kadar bioetanol yang tinggi. Interaksi ragi tape 0,6% dan ragi roti 0,3% (T2R1 merupakan interaksi terendah yang efektif menghasilkan kadar bioetanol yang dapat terbakar (36%. Interaksi ragi tape 0,9% dan ragi roti 0,9% (T3R3 menghasilkan kadar bioetanol tertinggi dengan rata-rata mencapai 49,8%.Cassava (Manihot utilissima, Pohl var Mukibat is potential for bioethanol feedstock. The study aimed to determine the effects of the interaction of bread yeast and tape yeast on the concentration of mukibat cassava bioethanol and to determine the lowest effective interaction can produce flammable bioethanol. The samples used were mukibat cassava aged 7 months with an average weight of 500 grams. Research design was completely randomized design factorial, tape yeast concentration (0%, 0.3%, 0.6% and 0.9% and the concentration of yeast bread (0%, 0.3%, 0.6% and 0.9% with 3 replications. Parameters measured include the number of yeast cells (supporting data

  13. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Bulatova, Regina; Tok, A. I Y

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casti...

  14. Sacral orientation and spondylolysis.

    Science.gov (United States)

    Peleg, Smadar; Dar, Gali; Steinberg, Nili; Masharawi, Youssef; Been, Ella; Abbas, Janan; Hershkovitz, Israel

    2009-12-01

    A descriptive study (based on skeletal material) was designed to measure sacral anatomic orientation (SAO) in individuals with and without spondylolysis. To test whether a relationship between SAO and spondylolysis exists. Spondylolysis is a stress fracture in the pars interarticularis (mainly of L5). The natural history of the phenomenon has been debated for years with opinions divided, i.e., is it a developmental condition or a stress fracture phenomenon. There is some evidence to suggest that sacral orientation can be a "key player" in revealing the etiology of spondylolysis. The pelvis was anatomically reconstructed and SAO was measured as the angle created between the intersection of a line running parallel to the superior surface of the sacrum and a line running between the anterior superior iliac spine (ASIS) and the anterior-superior edge of the symphysis pubis (PUBIS).SAO was measured in 99 adult males with spondylolysis and 125 adult males without spondylolysis. The difference between the groups was tested using an unpaired t test. Spondylolysis prevalence is significantly higher in African-Americans compared to European-Americans: 5.4% versus 2.04% in males (P < 0.001) and 2.31% versus 0.4%, P < 0.001 in females. SAO was significantly lower in the spondylolytic group (44.07 degrees +/- 11.46 degrees) compared to the control group (51.07 degrees +/- 8.46 degrees, P < 0.001). A more horizontally oriented sacrum leads to direct impingement on L5 pars interarticularis by both L4 inferior articular facet superiorly and S1 superior articular facet inferiorly. Repetitive stress due to standing (daily activities) or sitting increases the "pincer effect" on this area, and eventually may lead to incomplete synostosis of the neural arch.

  15. Simultaneous display of MRA and MPR in detecting vascular compression for trigeminal neuralgia or hemifacial spasm: comparison with oblique sagittal views of MRI

    International Nuclear Information System (INIS)

    Arbab, A.S.; Aoki, S.; Yoshikawa, T.; Kumagai, H.; Araki, T.; Nishiyama, Y.; Nagaseki, Y.; Nukui, H.

    2000-01-01

    A new technique, simultaneous display of magnetic resonance angiography (MRA) and multiplanar reconstruction (MPR), was performed by a workstation to identify the involved vessels in patients with trigeminal neuralgia (TN) or hemifacial spasm (HFS), and the results were compared with those of oblique sagittal MRI technique. Twelve patients with either HFS or TN were prospectively assessed by simultaneous display of MRA and MPR, and oblique sagittal techniques, to point out the neurovascular compression and to identify the involved vessels. Three-dimensional (3D) time-of-flight (TOF) spoiled gradient-echo (SPGR) images were acquired to create MRA and MPR. Oblique sagittal views were also created and displayed on films. A total of 15 vessels in 12 patients were identified as compressing vessels during surgery. Simultaneous display of MRA and MPR technique pointed out the presence of vessels at and/or around root entry/exit zone (REZ) in all 12 patients, but proper identification by the name of the individual vessel was correct in 13 of 15 cases. However, oblique sagittal technique indicated the presence of vessels at and/or around REZ in 11 patients, but only 8 of 14 vessels were correctly identified. Our new method, simultaneous display of MRA-MPR, facilitated correct identification of the involved vessels compared with the oblique sagittal view method. (orig.)

  16. Association of myelopathy scores with cervical sagittal balance and normalized spinal cord volume: analysis of 56 preoperative cases from the AOSpine North America Myelopathy study.

    Science.gov (United States)

    Smith, Justin S; Lafage, Virginie; Ryan, Devon J; Shaffrey, Christopher I; Schwab, Frank J; Patel, Alpesh A; Brodke, Darrel S; Arnold, Paul M; Riew, K Daniel; Traynelis, Vincent C; Radcliff, Kris; Vaccaro, Alexander R; Fehlings, Michael G; Ames, Christopher P

    2013-10-15

    Post hoc analysis of prospectively collected data. Development of methods to determine in vivo spinal cord dimensions and application to correlate preoperative alignment, myelopathy, and health-related quality-of-life scores in patients with cervical spondylotic myelopathy (CSM). CSM is the leading cause of spinal cord dysfunction. The association between cervical alignment, sagittal balance, and myelopathy has not been well characterized. This was a post hoc analysis of the prospective, multicenter AOSpine North America CSM study. Inclusion criteria for this study required preoperative cervical magnetic resonance imaging (MRI) and neutral sagittal cervical radiography. Techniques for MRI assessment of spinal cord dimensions were developed. Correlations between imaging and health-related quality-of-life scores were assessed. Fifty-six patients met inclusion criteria (mean age = 55.4 yr). The modified Japanese Orthopedic Association (mJOA) scores correlated with C2-C7 sagittal vertical axis (SVA) (r = -0.282, P = 0.035). Spinal cord volume correlated with cord length (r = 0.472, P balance (C2-C7 SVA) to myelopathy severity. We found a moderate negative correlation in kyphotic patients of cord volume and cross-sectional area to mJOA scores. The opposite (positive correlation) was found for lordotic patients, suggesting a relationship of cord volume to myelopathy that differs on the basis of sagittal alignment. It is interesting to note that sagittal balance but not kyphosis is tied to myelopathy score. Future work will correlate alignment changes to cord morphology changes and myelopathy outcomes. SUMMARY STATEMENTS: This is the first study to correlate sagittal balance (C2-C7 SVA) to myelopathy severity. We found a moderate negative correlation in kyphotic patients of cord volume and cross-sectional area to mJOA scores. The opposite (positive correlation) was found for lordotic patients, suggesting a relationship of cord volume to myelopathy that differs on the

  17. Influence of spinal sagittal alignment, body balance, muscle strength, and physical ability on falling of middle-aged and elderly males.

    Science.gov (United States)

    Imagama, Shiro; Ito, Zenya; Wakao, Norimitsu; Seki, Taisuke; Hirano, Kenichi; Muramoto, Akio; Sakai, Yoshihito; Matsuyama, Yukihiro; Hamajima, Nobuyuki; Ishiguro, Naoki; Hasegawa, Yukiharu

    2013-06-01

    Risk factors for falling in elderly people remain uncertain, and the effects of spinal factors and physical ability on body balance and falling have not been examined. The objective of this study was to investigate how factors such as spinal sagittal alignment, spinal range of motion, body balance, muscle strength, and gait speed influence falling in the prospective cohort study. The subjects were 100 males who underwent a basic health checkup. Balance, SpinalMouse(®) data, grip strength, back muscle strength, 10-m gait time, lumbar lateral standing radiographs, body mass index, and fall history over the previous year were examined. Platform measurements of balance included the distance of movement of the center of pressure (COP) per second (LNG/TIME), the envelopment area traced by movement of the COP (E AREA), and the LNG/E AREA ratio. The thoracic/lumbar angle ratio (T/L ratio) and sagittal vertical axis (SVA) were used as an index of sagittal balance. LNG/TIME and E AREA showed significant positive correlations with age, T/L ratio, SVA, and 10-m gait time; and significant negative correlations with lumbar lordosis angle, sacral inclination angle, grip strength and back muscle strength. Multiple regression analysis showed significant differences for LNG/TIME and E AREA with T/L ratio, SVA, lumbar lordosis angle and sacral inclination angle (R (2) = 0.399). Twelve subjects (12 %) had experienced a fall over the past year. Age, T/L ratio, SVA, lumbar lordosis angle, sacral inclination angle, grip strength, back muscle strength, 10-m gait time, height of the intervertebral disc, osteophyte formation in radiographs and LNG/E AREA differed significantly between fallers and non-fallers. The group with SVA > 40 mm (n = 18) had a significant higher number of subjects with a single fall (6 single fallers/18: p = 0.0075) and with multiple falls (4 multiple fallers/18: p = 0.0095). Good spinal sagittal alignment, muscle strength and 10-m gait speed improve body balance

  18. THE MID - TERM EFFECT OF KINESIO TAPING ON PEAK POWER OF QUADRICEPS AND HAMSTRING MUSCLES AFTER ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Amel Khabazan Mahdi

    2017-01-01

    Full Text Available Purpose: The aim of this study was to assess mid- term effect of Kinesio tape on peak power of quadriceps and hamstrings muscles after ACL reconstruction 24 hours after taping. Material: Thirty six men who had undergone ACL reconstruction and completed physiotherapy periods (6 months were assigned to no taping, placebo and taping groups. Peak power was tested before and 24 hours after taping by Isokinetic dynamometry. Data was analyzed by SPSS software 19. ANOVA and post hoc test (LSD were used for interpretive analysis. Results: The results showed that the effect of Kinesio tape on peak power of quadriceps muscles at velocities of 180°/s and 300°/s was significant. In the hamstring muscles, significant effects were obtained at velocities of 60°/s, 180°/s & 300°/s. Conclusion: Positive impacts of Kinesio tape on muscular peak power among athletes who had ACL reconstruction were observed. Regardless of psychological effect and reducing re - injury fear, Kinesio - tape causes to stabilize and increase effective range of motion of the knee, so it is recommended that in the explosive training, athletes who have ACL reconstruction should use tape to reduce the probability of re-injury and increase muscle power.

  19. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    International Nuclear Information System (INIS)

    Gu, C.; Alamgir, A.K.M.; Qu, T.M.; Han, Z.

    2008-01-01

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I c increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account

  20. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)], E-mail: guchen@tsinghua.edu.cn; Alamgir, A.K.M. [Faculty of Engineering, Yokohama National University, 75-9 Tokiwadai, Hodogaya, ku, Yokohama (Japan); Qu, T.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory for Advanced Materials Processing Technology, Ministry of Education (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)

    2008-09-15

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I{sub c} increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account.