WorldWideScience

Sample records for sagittal knee motion

  1. Knee motion variability in patients with knee osteoarthritis: the effect of self-reported instability

    Science.gov (United States)

    Gustafson, Jonathan A.; Robinson, Megan E.; Fitzgerald, G. Kelley; Tashman, Scott; Farrokhi, Shawn

    2015-01-01

    Background Knee osteoarthritis has been previously associated with a stereotypical knee-stiffening gait pattern and reduced knee joint motion variability due to increased antagonist muscle co-contractions and smaller utilized arc of motion during gait. However, episodic self-reported instability may be a sign of excessive motion variability for a large subgroup of patients with knee osteoarthritis. The objective of this work was to evaluate the differences in knee joint motion variability during gait in patients with knee osteoarthritis with and without self-reported instability compared to a control group of older adults with asymptomatic knees. Methods Forty-three subjects, 8 with knee osteoarthritis but no reports of instability (stable), 11 with knee osteoarthritis and self-reported instability (unstable), and 24 without knee osteoarthritis or instability (control) underwent Dynamic Stereo X-ray analysis during a decline gait task on a treadmill. Knee motion variability was assessed using parametric phase plots during the loading response phase of decline gait. Findings The stable group demonstrated decreased sagittal-plane motion variability compared to the control group (p=0.04), while the unstable group demonstrated increased sagittal-plane motion variability compared to the control (p=0.003) and stable groups (pknee motion variability in patients with knee osteoarthritis without self-reported instability supports previous research. However, presence of self-reported instability is associated with increased knee motion variability in patients with knee osteoarthritis and warrants further investigation. PMID:25796536

  2. Association of baseline knee sagittal dynamic joint stiffness during gait and 2-year patellofemoral cartilage damage worsening in knee osteoarthritis.

    Science.gov (United States)

    Chang, A H; Chmiel, J S; Almagor, O; Guermazi, A; Prasad, P V; Moisio, K C; Belisle, L; Zhang, Y; Hayes, K; Sharma, L

    2017-02-01

    Knee sagittal dynamic joint stiffness (DJS) describes the biomechanical interaction between change in external knee flexion moment and flexion angular excursion during gait. In theory, greater DJS may particularly stress the patellofemoral (PF) compartment and thereby contribute to PF osteoarthritis (OA) worsening. We hypothesized that greater baseline knee sagittal DJS is associated with PF cartilage damage worsening 2 years later. Participants all had OA in at least one knee. Knee kinematics and kinetics during gait were recorded using motion capture systems and force plates. Knee sagittal DJS was computed as the slope of the linear regression line for knee flexion moments vs angles during the loading response phase. Knee magnetic resonance imaging (MRI) scans were obtained at baseline and 2 years later. We assessed the association between baseline DJS and baseline-to-2-year PF cartilage damage worsening using logistic regression with generalized estimating equations (GEE). Our sample had 391 knees (204 persons): mean age 64.2 years (SD 10.0); body mass index (BMI) 28.4 kg/m 2 (5.7); 76.5% women. Baseline knee sagittal DJS was associated with baseline-to-2-year cartilage damage worsening in the lateral (OR = 5.35, 95% CI: 2.37-12.05) and any PF (OR = 2.99, 95% CI: 1.27-7.04) compartment. Individual components of baseline DJS (i.e., change in knee moment or angle) were not associated with subsequent PF disease worsening. Capturing the concomitant effect of knee kinetics and kinematics during gait, knee sagittal DJS is a potentially modifiable risk factor for PF disease worsening. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  3. How does knee pain affect trunk and knee motion during badminton forehand lunges?

    Science.gov (United States)

    Huang, Ming-Tung; Lee, Hsing-Hsan; Lin, Cheng-Feng; Tsai, Yi-Ju; Liao, Jen-Chieh

    2014-01-01

    Badminton requires extensive lower extremity movement and a precise coordination of the upper extremity and trunk movements. Accordingly, this study investigated motions of the trunk and the knee, control of dynamic stability and muscle activation patterns of individuals with and without knee pain. Seventeen participants with chronic knee pain and 17 healthy participants participated in the study and performed forehand forward and backward diagonal lunges. This study showed that those with knee pain exhibited smaller knee motions in frontal and horizontal planes during forward lunge but greater knee motions in sagittal plane during backward lunge. By contrast, in both tasks, the injured group showed a smaller value on the activation level of the paraspinal muscles in pre-impact phase, hip-shoulder separation angle, trunk forward inclination range and peak centre of mass (COM) velocity. Badminton players with knee pain adopt a more conservative movement pattern of the knee to minimise recurrence of knee pain. The healthy group exhibit better weight-shifting ability due to a greater control of the trunk and knee muscles. Training programmes for badminton players with knee pain should be designed to improve both the neuromuscular control and muscle strength of the core muscles and the knee extensor with focus on the backward lunge motion.

  4. Benefits of sagittal-oblique MRI reconstruction of anterior cruciate ligament of the knee

    International Nuclear Information System (INIS)

    Nenezić, D.

    2015-01-01

    Full text: MRI examination of the anterior cruciate ligament (ACL) of the knee gives valuable information for conventional, physiatrist and/or arthroscopic microinvasiv treatment. three planar MRI examination and 3D reconstructions are highly precise in the analysis of the intra and periarticular structures, with exceptions of anterior cruciate ligament. Direct contact with the roof of the intercondilar fossa (in the full extension during the examination) and its specific orientation makes visualization of ACL diagnostically problematic. In a one year period precise protocol for MRI visualization of ACL was tested and applied as “Sagittal Oblique MRI Reconstruction”. In short, it has been Angled biplanar reconstruction in the parasagital and paratransversal planes (patientrelated and arbitrary selected in full extension), on T2, 2mm slice and 0,2 mm gap. 153 MRI examinations of the patients with lesions of the ACL were included in the study in the Clinical Center of Montenegro during 2005 year. Beside standard Knee MRI protocol all patients had the Sagittal Oblique MRI reconstruction of ACL and the Flexion MRI examination, to compare with. The Sagittal Oblique MRI reconstruction of ACL it is adapted to the concrete morphology of the patients ACL and it does not depend of the volume of the examined knee. In comparison with the Standard Knee MRI protocol and with the Flexion MRI examination, the Sagittal Oblique MRI reconstruction of ACL takes less time to perform, and the ligament is shown in fool length at three to five slices, which is more than with the both compared protocols. Sagittal Oblique MRI Reconstruction of ACL is therefore patient dependable, orientated in shape of concrete ligament of the patient’s knee. In combination with age, occupation, physical activity and level of patients while to contribute in healing process, the Sagittal Oblique MRI reconstruction of ACL contribute to scholastic approach, as highest benefit to patients with

  5. Sagittal-Plane Knee Moment During Gait and Knee Cartilage Thickness.

    Science.gov (United States)

    Schmitz, Randy J; Harrison, David; Wang, Hsin-Min; Shultz, Sandra J

    2017-06-02

      Understanding the factors associated with thicker cartilage in a healthy population is important when developing strategies aimed at minimizing the cartilage thinning associated with knee osteoarthritis progression. Thicker articular cartilage is commonly thought to be healthier cartilage, but whether the sagittal-plane biomechanics important to gait are related to cartilage thickness is unknown.   To determine the relationship of a weight-bearing region of the medial femoral condyle's cartilage thickness to sagittal gait biomechanics in healthy individuals.   Descriptive laboratory study.   Laboratory.   Twenty-eight healthy participants (15 women: age = 21.1 ± 2.1 years, height = 1.63 ± 0.07 m, weight = 64.6 ± 9.9 kg; 13 men: age = 22.1 ± 2.9 years, height = 1.79 ± 0.05 m, weight = 75.2 ± 9.6 kg).   Tibiofemoral angle (°) was obtained via goniometric assessment, thickness of the medial femoral condyle cartilage (mm) was obtained via ultrasound imaging, and peak internal knee-extensor moment (% body weight · height) was measured during 10 trials of over-ground walking at a self-selected pace. We used linear regression to examine the extent to which peak internal knee-extensor moment predicted cartilage thickness after accounting for tibiofemoral angle and sex.   Sex and tibiofemoral angle (12.3° ± 3.2°) were entered in the initial step as control factors (R 2 = 0.01, P = .872). In the final step, internal knee-extensor moment (1.5% ± 1.3% body weight · height) was entered, which resulted in greater knee-extensor moment being related to greater cartilage thickness (2.0 ± 0.3 mm; R 2 Δ = 0.31, PΔ = .003).   Individuals who walked with a greater peak internal knee-extensor moment during gait had a cartilage structure that is generally considered beneficial in a healthy population. Our study offers promising findings that a potentially modifiable biomechanical factor is associated with cartilage status in a healthy population

  6. Global analysis of sagittal spinal alignment in major deformities: correlation between lack of lumbar lordosis and flexion of the knee.

    Science.gov (United States)

    Obeid, Ibrahim; Hauger, Olivier; Aunoble, Stéphane; Bourghli, Anouar; Pellet, Nicolas; Vital, Jean-Marc

    2011-09-01

    It has become well recognised that sagittal balance of the spine is the result of an interaction between the spine and the pelvis. Knee flexion is considered to be the last compensatory mechanism in case of sagittal imbalance, but only few studies have insisted on the relationship between spino-pelvic parameters and lower extremity parameters. Correlation between the lack of lumbar lordosis and knee flexion has not yet been established. A retrospective study was carried out on 28 patients with major spinal deformities. The EOS system was used to measure spinal and pelvic parameters and the knee flexion angle; the lack of lumbar lordosis was calculated after prediction of lumbar lordosis with two different formulas. Correlation analysis between the different measured parameters was performed. Lumbar lordosis correlated with sacral slope (r = -0.71) and moderately with knee flexion angle (r = 0.42). Pelvic tilt correlated moderately with knee flexion angle (r = 0.55). Lack of lumbar lordosis correlated best with knee flexion angle (r = 0.72 and r = 0.63 using the two formulas, respectively). Knee flexion as a compensatory mechanism to sagittal imbalance was well correlated to the lack of lordosis and, depending on the importance of the former parameter, the best procedure to correct sagittal imbalance could be chosen.

  7. Gender differences of sagittal knee and ankle biomechanics during stair-to-ground descent transition.

    Science.gov (United States)

    Hong, Yoon No Gregory; Shin, Choongsoo S

    2015-12-01

    Falls on stairs often result in severe injury and occur twice as frequently in women. However, gender differences in kinetics and kinematics during stair descent are unknown. Thus, this study aimed to determine whether gender differences of knee and ankle biomechanics exist in the sagittal plane during the stair-to-ground descending transition. It was hypothesized that 1) women would reveal higher ground-toe-trochanter angle and lower ground-toe length during stair-to-ground descent transition than men; and 2) women would reveal lower peak knee extension moment during stair-to-ground descent transition than men. Fifteen men and fifteen women were recruited and performed a stair descent activity. Kinetic and kinematic data were obtained using a force plate and motion capture system. The women performed the stair descent with a lower peak knee extension moment and a peak knee power at the early weight acceptance phase. The women also revealed a higher ground-toe-trochanter angle and a lower ground-toe length, which indicated a more forward position of the lower extremity relative to the toe contact point at both the initial contact and at the time of peak kinematic and kinetic events. This study found that knee and ankle kinematics and kinetics differed significantly between the genders due to differences in ground-toe-trochanter angle. Women have a different stair descending strategy that reduces the demand of the lower extremity muscle function, but this strategy seems to increase the risk of falls. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Does Knee Osteoarthritis Differentially Modulate Proprioceptive Acuity in the Frontal and Sagittal Planes of the Knee?

    Science.gov (United States)

    Cammarata, Martha L; Schnitzer, Thomas J; Dhaher, Yasin Y

    2012-01-01

    Objective Impaired proprioception may alter joint loading and contribute to the progression of knee osteoarthritis (OA). Though frontal plane loading at the knee contributes to OA, proprioception and its modulation with OA in this direction have not been examined. The aim of this study was to assess knee proprioceptive acuity in the frontal and sagittal planes in knee OA and healthy participants. We hypothesized that proprioceptive acuity will be decreased in the OA population in both planes of movement. Methods Thirteen persons with knee OA and fourteen healthy age-matched subjects participated. Proprioceptive acuity was assessed in varus, valgus, flexion, and extension using the threshold to detection of passive movement (TDPM). Repeated measures analysis of variance was used to assess differences in TDPM between subject groups and across movement directions. Linear regression analyses were performed to assess the correlation of TDPM between and within planes of movement. Results TDPM was found to be significantly higher (Pplanes of movement were only weakly correlated, especially in the OA group. Conclusions Consistent differences in TDPM between the OA and control groups across all movement directions suggest a global, not direction-specific, reduction in sensation in knee OA patients. PMID:21547895

  9. [Restricted motion after total knee arthroplasty].

    Science.gov (United States)

    Kucera, T; Urban, K; Karpas, K; Sponer, P

    2007-10-01

    The aim of the study was to ascertain what proportion of patients undergoing total knee arthroplasty (TKA) complain of restricted knee joint motion, and to investigate options for improvement of this situation. Our evaluation included a group of 796 patients treated with TKA at our department in the period from January 1, 1990, to December 31, 2004. In all cases, a condylar implant with preservation of the posterior cruciate ligaments was used. In addition to medical history, the range of motion, knee joint malalignment and radiological findings were assessed before surgery. After THA, the type of implant and complications, if any, were recorded, and improvement in joint motion was followed up. Based on the results of Kim et al., flexion contracture equal to or higher than 15 degrees and/or flexion less than 75 degrees were made the criteria of stiffness after THA. Patients with restricted THA motion who had aseptic or septic implant loosening were not included. Of the 796 evaluated patients, 32 (4.14 %) showed restricted motion after total knee arthroplasty, as assessed by the established criteria. In 16 patients, stiffness defined by these criteria had existed before surgery, and three patients showed an excessive production of adhesions and heterotopic ossifications. In three patients, the implantation procedure resulted in an elevated level of the original joint line and subsequent development of patella infera and increased tension of the posterior cruciate ligament. Four patients declined physical therapy and, in six, the main cause of stiffness could not be found. Seventeen patients did not require surgical therapy for restricted motion; TKA provided significant pain relief and they considered the range of motion achieved to be sufficient. One patient underwent redress 3 months after surgery, but with no success. Repeated releases of adhesions, replacement of a polyethylene liner and revision surgery of the extensor knee structures were performed in 15

  10. Knee joint passive stiffness and moment in sagittal and frontal planes markedly increase with compression.

    Science.gov (United States)

    Marouane, H; Shirazi-Adl, A; Adouni, M

    2015-01-01

    Knee joints are subject to large compression forces in daily activities. Due to artefact moments and instability under large compression loads, biomechanical studies impose additional constraints to circumvent the compression position-dependency in response. To quantify the effect of compression on passive knee moment resistance and stiffness, two validated finite element models of the tibiofemoral (TF) joint, one refined with depth-dependent fibril-reinforced cartilage and the other less refined with homogeneous isotropic cartilage, are used. The unconstrained TF joint response in sagittal and frontal planes is investigated at different flexion angles (0°, 15°, 30° and 45°) up to 1800 N compression preloads. The compression is applied at a novel joint mechanical balance point (MBP) identified as a point at which the compression does not cause any coupled rotations in sagittal and frontal planes. The MBP of the unconstrained joint is located at the lateral plateau in small compressions and shifts medially towards the inter-compartmental area at larger compression forces. The compression force substantially increases the joint moment-bearing capacities and instantaneous angular rigidities in both frontal and sagittal planes. The varus-valgus laxities diminish with compression preloads despite concomitant substantial reductions in collateral ligament forces. While the angular rigidity would enhance the joint stability, the augmented passive moment resistance under compression preloads plays a role in supporting external moments and should as such be considered in the knee joint musculoskeletal models.

  11. Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait.

    Science.gov (United States)

    Li, Jing-Sheng; Tsai, Tsung-Yuan; Felson, David T; Li, Guoan; Lewis, Cara L

    2017-01-01

    Knee joint pain is a common symptom in obese individuals and walking is often prescribed as part of management programs. Past studies in obese individuals have focused on standing alignment and kinematics in the sagittal and coronal planes. Investigation of 6 degree-of-freedom (6DOF) knee joint kinematics during standing and gait is important to thoroughly understand knee function in obese individuals with knee pain. This study aimed to investigate the 6DOF knee joint kinematics in standing and during gait in obese patients using a validated fluoroscopic imaging system. Ten individuals with obesity and knee pain were recruited. While standing, the knee was in 7.4±6.3°of hyperextension, 2.8±3.3° of abduction and 5.6±7.3° of external rotation. The femoral center was located 0.7±3.1mm anterior and 5.1±1.5mm medial to the tibial center. During treadmill gait, the sagittal plane motion, i.e., flexion/extension and anterior-posterior translation, showed a clear pattern. Specifically, obese individuals with knee pain maintained the knee in more flexion and more anterior tibial translation during most of the stance phase of the gait cycle and had a reduced total range of knee flexion when compared to a healthy non-obese group. In conclusion, obese individuals with knee pain used hyperextension knee posture while standing, but maintained the knee in more flexion during gait with reduced overall range of motion in the 6DOF analysis.

  12. The influence of heel height on sagittal plane knee kinematics during landing tasks in recreationally active and athletic collegiate females.

    Science.gov (United States)

    Lindenberg, Kelly M; Carcia, Christopher R; Phelps, Amy L; Martin, Robroy L; Burrows, Anne M

    2011-09-01

    To determine if heel height alters sagittal plane knee kinematics when landing from a forward hop or drop landing. Knee angles close to extension during landing are theorized to increase ACL injury risk in female athletes. Fifty collegiate females performed two single-limb landing tasks while wearing heel lifts of three different sizes (0, 12 & 24 mm) attached to the bottom of a sneaker. Using an electrogoniometer, sagittal plane kinematics (initial contact [KA(IC)], peak flexion [KA(Peak)], and rate of excursion [RE]) were examined. Repeated measures ANOVAs were used to determine the influence of heel height on the dependent measures. Forward hop task- KA(IC) with 0 mm, 12 mm, and 24 mm lifts were 8.88±6.5, 9.38±5.8 and 11.28±7.0, respectively. Significant differences were noted between 0 and 24 mm lift (psneaker significantly alters sagittal plane knee kinematics upon landing from a unilateral forward hop but not from a drop jump.

  13. Knee joint motion and muscle activation patterns are altered during gait in individuals with moderate hip osteoarthritis compared to asymptomatic cohort.

    Science.gov (United States)

    Rutherford, Derek; Moreside, Janice; Wong, Ivan

    2015-07-01

    Knee replacements are common after hip replacement for end stage osteoarthritis. Whether abnormal knee mechanics exist in moderate hip osteoarthritis remains undetermined and has implications for understanding early osteoarthritis joint mechanics. The purpose of this study was to determine whether three-dimensional (3D) knee motion and muscle activation patterns in individuals with moderate hip osteoarthritis differ from an asymptomatic cohort and whether these features differ between contra- and ipsilateral knees. 3D motions and medial and lateral quadriceps and hamstring surface electromyography were recorded on 20 asymptomatic individuals and 20 individuals with moderate hip osteoarthritis during treadmill walking, using standardized collection and processing procedures. Principal component analysis was used to derive electromyographic amplitude and temporal waveform features. 3D stance-phase range of motion was calculated. A 2-factor repeated analysis of variance determined significant within-group leg and muscle differences. Student's t-tests identified between group differences, with Bonferroni corrections where applicable (α=0.05). Lower sagittal plane motion between early and mid/late stance (5°, P=0.004, effect size: 0.96) and greater mid-stance quadriceps activity was found in the osteoarthritis group (P=0.01). Compared to the ipsilateral knee, a borderline significant increase in mid-stance hamstring activity was found in the contra-lateral knee of the hip osteoarthritis group (P=0.018). Bilateral knee mechanics were altered, suggesting potentially increased loads and knee muscle fatigue. There was no indication that one knee is more susceptible to osteoarthritis than the other, thus clinicians should include bilateral knee analysis when treating patients with hip osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. A Comparison of Plain Radiography with Computer Tomography in Determining Coronal and Sagittal Alignments following Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Solayar GN

    2017-07-01

    Full Text Available INTRODUCTION: Optimal coronal and sagittal component positioning is important in achieving a successful outcome following total knee arthroplasty (TKA. Modalities to determine post-operative alignment include plain radiography and computer tomography (CT imaging. This study aims to determine the accuracy and reliability of plain radiographs in measuring coronal and sagittal alignment following TKA. MATERIALS AND METHODS: A prospective, consecutive study of 58 patients undergoing TKA was performed comparing alignment data from plain radiographs and CT imaging. Hip- knee-angle (HKA, sagittal femoral angle (SFA and sagittal tibial angle (STA measurements were taken by two observers from plain radiographs and compared with CT alignment. Intra- and inter-observer correlation was calculated for each measurement. RESULTS: Intra-observer correlation was excellent for HKA (r>0.89 with a mean difference of 0.95 and STA (r>0.8 compared to SFA (r=0.5. When comparing modalities (radiographs vs CT, HKA estimations for both observers showed the least maximum and mean differences while SFA observations were the least accurate. CONCLUSION: Radiographic estimation of HKA showed excellent intra- and inter-observer correlation and corresponds well with CT imaging. However, radiographic estimation of sagittal plane alignment was less reliably measured and correlated less with CT imaging. Plain radiography was found to be inferior to CT for estimation of biplanar prosthetic alignment following TKA.

  15. Influence of Body Mass Index on Sagittal Knee Range of Motion and Gait Speed Recovery 1-Year After Total Knee Arthroplasty.

    Science.gov (United States)

    Bonnefoy-Mazure, Alice; Martz, Pierre; Armand, Stéphane; Sagawa, Yoshimasa; Suva, Domizio; Turcot, Katia; Miozzari, Hermes H; Lübbeke, Anne

    2017-08-01

    The purpose of this prospective study was to investigate the influence of body mass index (BMI) on gait parameters preoperatively and 1 year after total knee arthroplasty (TKA). Seventy-nine patients were evaluated before and 1 year after TKA using clinical gait analysis. The gait velocity, the knee range of motion (ROM) during gait, their gains (difference between baseline and 1 year after TKA), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), quality of life, and patient satisfaction were assessed. Nonobese (BMI gait speed and ROM gains. Adjustment was performed for gender, age, and WOMAC pain improvement. At baseline, gait velocity and knee ROM were significantly lower in obese compared with those in the nonobese patients (0.99 ± 0.27 m/s vs 1.11 ± 0.18 m/s; effect size, 0.53; P = .021; and ROM, 41.33° ± 9.6° vs 46.05° ± 8.39°; effect size, 0.52; P = .022). Univariate and multivariate linear regressions did not show any significant relation between gait speed gain or knee ROM gain and BMI. At baseline, obese patients were more symptomatic than nonobese (WOMAC pain: 36.1 ± 14.0 vs 50.4 ± 16.9; effect size, 0.9; P < .001), and their improvement was significantly higher (WOMAC pain gain, 44.5 vs 32.3; effect size, 0.59; P = .011). These findings show that all patients improved biomechanically and clinically, regardless of their BMI. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Position controlled Knee Rehabilitation Orthotic Device for Patients after Total Knee Replacement Arthroplasty

    Science.gov (United States)

    Wannaphan, Patsiri; Chanthasopeephan, Teeranoot

    2016-11-01

    Knee rehabilitation after total knee replacement arthroplasty is essential for patients during their post-surgery recovery period. This study is about designing one degree of freedom knee rehabilitation equipment to assist patients for their post-surgery exercise. The equipment is designed to be used in sitting position with flexion/extension of knee in sagittal plane. The range of knee joint motion is starting from 0 to 90 degrees angle for knee rehabilitation motion. The feature includes adjustable link for different human proportions and the torque feedback control at knee joint during rehabilitation and the control of flexion/extension speed. The motion of the rehabilitation equipment was set to move at low speed (18 degrees/sec) for knee rehabilitation. The rehabilitation link without additional load took one second to move from vertical hanging up to 90° while the corresponding torque increased from 0 Nm to 2 Nm at 90°. When extra load is added, the link took 1.5 seconds to move to 90° The torque is then increased from 0 Nm to 4 Nm. After a period of time, the speed of the motion can be varied. User can adjust the motion to 40 degrees/sec during recovery activity of the knee and users can increase the level of exercise or motion up to 60 degrees/sec to strengthen the muscles during throughout their rehabilitation program depends on each patient. Torque control is included to prevent injury. Patients can use the equipment for home exercise to help reduce the number of hospital visit while the patients can receive an appropriate therapy for their knee recovery program.

  17. Modelling of the Human Knee Joint Supported by Active Orthosis

    Science.gov (United States)

    Musalimov, V.; Monahov, Y.; Tamre, M.; Rõbak, D.; Sivitski, A.; Aryassov, G.; Penkov, I.

    2018-02-01

    The article discusses motion of a healthy knee joint in the sagittal plane and motion of an injured knee joint supported by an active orthosis. A kinematic scheme of a mechanism for the simulation of a knee joint motion is developed and motion of healthy and injured knee joints are modelled in Matlab. Angles between links, which simulate the femur and tibia are controlled by Simulink block of Model predictive control (MPC). The results of simulation have been compared with several samples of real motion of the human knee joint obtained from motion capture systems. On the basis of these analyses and also of the analysis of the forces in human lower limbs created at motion, an active smart orthosis is developed. The orthosis design was optimized to achieve an energy saving system with sufficient anatomy, necessary reliability, easy exploitation and low cost. With the orthosis it is possible to unload the knee joint, and also partially or fully compensate muscle forces required for the bending of the lower limb.

  18. Modelling of the Human Knee Joint Supported by Active Orthosis

    Directory of Open Access Journals (Sweden)

    Musalimov V.

    2018-02-01

    Full Text Available The article discusses motion of a healthy knee joint in the sagittal plane and motion of an injured knee joint supported by an active orthosis. A kinematic scheme of a mechanism for the simulation of a knee joint motion is developed and motion of healthy and injured knee joints are modelled in Matlab. Angles between links, which simulate the femur and tibia are controlled by Simulink block of Model predictive control (MPC. The results of simulation have been compared with several samples of real motion of the human knee joint obtained from motion capture systems. On the basis of these analyses and also of the analysis of the forces in human lower limbs created at motion, an active smart orthosis is developed. The orthosis design was optimized to achieve an energy saving system with sufficient anatomy, necessary reliability, easy exploitation and low cost. With the orthosis it is possible to unload the knee joint, and also partially or fully compensate muscle forces required for the bending of the lower limb.

  19. Estimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Frank J. Wouda

    2018-03-01

    Full Text Available Analysis of running mechanics has traditionally been limited to a gait laboratory using either force plates or an instrumented treadmill in combination with a full-body optical motion capture system. With the introduction of inertial motion capture systems, it becomes possible to measure kinematics in any environment. However, kinetic information could not be provided with such technology. Furthermore, numerous body-worn sensors are required for a full-body motion analysis. The aim of this study is to examine the validity of a method to estimate sagittal knee joint angles and vertical ground reaction forces during running using an ambulatory minimal body-worn sensor setup. Two concatenated artificial neural networks were trained (using data from eight healthy subjects to estimate the kinematics and kinetics of the runners. The first artificial neural network maps the information (orientation and acceleration of three inertial sensors (placed at the lower legs and pelvis to lower-body joint angles. The estimated joint angles in combination with measured vertical accelerations are input to a second artificial neural network that estimates vertical ground reaction forces. To validate our approach, estimated joint angles were compared to both inertial and optical references, while kinetic output was compared to measured vertical ground reaction forces from an instrumented treadmill. Performance was evaluated using two scenarios: training and evaluating on a single subject and training on multiple subjects and evaluating on a different subject. The estimated kinematics and kinetics of most subjects show excellent agreement (ρ>0.99 with the reference, for single subject training. Knee flexion/extension angles are estimated with a mean RMSE <5°. Ground reaction forces are estimated with a mean RMSE < 0.27 BW. Additionaly, peak vertical ground reaction force, loading rate and maximal knee flexion during stance were compared, however, no significant

  20. The effect of age and knee osteoarthritis on muscle activation patterns and knee joint biomechanics during dual belt treadmill gait.

    Science.gov (United States)

    Rutherford, Derek; Baker, Matthew; Wong, Ivan; Stanish, William

    2017-06-01

    To compare a group of individuals with moderate medial compartment knee osteoarthritis (OA) to both an age-matched asymptomatic group of older adults and younger adults to determine whether differences in knee joint muscle activation patterns and joint biomechanics exist during gait between these three groups. 20 young adults, 20 older adults, and 40 individuals with moderate knee OA were recruited. Using standardized procedures, surface electromyograms were recorded from the vastus lateralis and medialis, rectus femoris and the medial and lateral hamstrings. All individuals walked on a dual belt instrumented treadmill while segment motions and ground reaction forces were recorded. Sagittal plane motion and net external sagittal and frontal plane moments were calculated. Discrete measures and principal component analyses extracted amplitude and temporal waveform features. Analysis of Variance models using Bonferroni corrections determined between and within group differences in these gait features (α=0.05). Individuals with knee OA have distinct biomechanics and muscle activation patterns when compared to age-matched asymptomatic adults and younger adults whereas differences between the young and older adults were few and included only measures of muscle activation amplitude. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Association of knee confidence with pain, knee instability, muscle strength, and dynamic varus-valgus joint motion in knee osteoarthritis.

    Science.gov (United States)

    Skou, Søren T; Wrigley, Tim V; Metcalf, Ben R; Hinman, Rana S; Bennell, Kim L

    2014-05-01

    To investigate associations between self-reported knee confidence and pain, self-reported knee instability, muscle strength, and dynamic varus-valgus joint motion during walking. We performed a cross-sectional analysis of baseline data from 100 participants with symptomatic and radiographic medial tibiofemoral compartment osteoarthritis (OA) and varus malalignment recruited for a randomized controlled trial. The extent of knee confidence, assessed using a 5-point Likert scale item from the Knee Injury and Osteoarthritis Outcome Score, was set as the dependent variable in univariable and multivariable ordinal regression, with pain during walking, self-reported knee instability, quadriceps strength, and dynamic varus-valgus joint motion during walking as independent variables. One percent of the participants were not troubled with lack of knee confidence, 17% were mildly troubled, 50% were moderately troubled, 26% were severely troubled, and 6% were extremely troubled. Significant associations were found between worse knee confidence and higher pain intensity, worse self-reported knee instability, lower quadriceps strength, and greater dynamic varus-valgus joint motion. The multivariable model consisting of the same variables significantly accounted for 24% of the variance in knee confidence (P knee confidence is associated with higher pain, worse self-reported knee instability, lower quadriceps muscle strength, and greater dynamic varus-valgus joint motion during walking. Since previous research has shown that worse knee confidence is predictive of functional decline in knee OA, addressing lack of knee confidence by treating these modifiable impairments could represent a new therapeutic target. Copyright © 2014 by the American College of Rheumatology.

  2. Composition of The Knee Index, a novel three-dimensional biomechanical index for knee joint load, in subjects with mild to moderate knee osteoarthritis

    DEFF Research Database (Denmark)

    Clausen, Brian; Andriacchi, Tom; Nielsen, Dennis Brandborg

    Background Knee joint load is an important factor associated with progression of knee osteoarthritis. To provide an overall understanding of knee joint loading, the Knee Index (KI) has been developed to include moments from all three planes (frontal, sagittal and transversal). However, before KI...... index of joint load for the knee, in patients with mild to moderate knee osteoarthritis. Methods The contribution of frontal, sagittal and transversal plane knee moments to KI was investigated in 24 subjects (13 women, age: 58 ± 7.6 years, BMI: 27.1 ± 3.0) with clinically diagnosed mild to moderate knee...... kinematics (i.e. the knee adduction moment), and secondarily the sagittal plane kinematics (i.e. the knee flexion moment). This holds promise for using KI in clinical trials since both frontal and sagittal knee joint moments have been suggested to be associated with the knee osteoarthritis disease...

  3. Knee Motion Generation Method for Transfemoral Prosthesis Based on Kinematic Synergy and Inertial Motion.

    Science.gov (United States)

    Sano, Hiroshi; Wada, Takahiro

    2017-12-01

    Previous research has shown that the effective use of inertial motion (i.e., less or no torque input at the knee joint) plays an important role in achieving a smooth gait of transfemoral prostheses in the swing phase. In our previous research, a method for generating a timed knee trajectory close to able-bodied individuals, which leads to sufficient clearance between the foot and the floor and the knee extension, was proposed using the inertial motion. Limb motions are known to correlate with each other during walking. This phenomenon is called kinematic synergy. In this paper, we measure gaits in level walking of able-bodied individuals with a wide range of walking velocities. We show that this kinematic synergy also exists between the motions of the intact limbs and those of the knee as determined by the inertial motion technique. We then propose a new method for generating the motion of the knee joint using its inertial motion close to the able-bodied individuals in mid-swing based on its kinematic synergy, such that the method can adapt to the changes in the motion velocity. The numerical simulation results show that the proposed method achieves prosthetic walking similar to that of able-bodied individuals with a wide range of constant walking velocities and termination of walking from steady-state walking. Further investigations have found that a kinematic synergy also exists at the start of walking. Overall, our method successfully achieves knee motion generation from the initiation of walking through steady-state walking with different velocities until termination of walking.

  4. Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

    Science.gov (United States)

    Kuriyama, Shinichi; Hyakuna, Katsufumi; Inoue, Satoshi; Kawai, Yasutsugu; Tamaki, Yasuyuki; Ito, Hiromu; Matsuda, Shuichi

    2018-05-01

    This study retrospectively evaluated the fate of mismatch between an uncemented femoral component and each femoral cut surface (i.e., wedge-shaped gap) relative to sagittal mechanical alignment in total knee arthroplasty (TKA). Primary TKA was performed on 99 consecutive knees. The femoral components were aligned to the sagittal mechanical axis with CT-based navigation. All patients were assessed with postoperative true lateral radiographs. Bone-side surfaces of the uncemented femoral component were divided into five zones: anterior flange, anterior chamfer, posterior chamfer, posterior part, and distal part, which were defined as zones 1 to 5, respectively. Bone filling of wedge-shaped gaps in each zone was evaluated after 1 year. Femoral anterior notching did not occur. However, wedge-shaped gaps were observed in at least one zone in 23 of 99 knees (23%), most frequently in zone 5 (18%). There were 9 and 7 gaps in zones 1 and 2, respectively. The femoral component showed malpositioning of approximately 3° of flexion in cases with wedge-shaped gaps in zones 2 and/or 5. After one year, 67% (6/9) of zone 1, 100% (7/7) of zone 2, and 94% (17/18) of zone 5 wedge-shaped gaps were filled in with new bone. Femoral alignment relative to sagittal mechanical axis caused wedge-shaped gaps due to unstable anterior bone cutting through hard bone, but the small gaps were not clinically significant and filled in within one year. Sagittal setting of the femoral component should aim for the anatomical axis rather than the mechanical axis. IV.

  5. Improvements in knee biomechanics during walking are associated with increased physical activity after total knee arthroplasty.

    Science.gov (United States)

    Arnold, John B; Mackintosh, Shylie; Olds, Timothy S; Jones, Sara; Thewlis, Dominic

    2015-12-01

    Total knee arthroplasty (TKA) in people with knee osteoarthritis increases knee-specific and general physical function, but it has not been established if there is a relationship between changes in these elements of functional ability. This study investigated changes and relationships between knee biomechanics during walking, physical activity, and use of time after TKA. Fifteen people awaiting TKA underwent 3D gait analysis before and six months after surgery. Physical activity and use of time were determined in free-living conditions from a high resolution 24-h activity recall. After surgery, participants displayed significant improvements in sagittal plane knee biomechanics and improved their physical activity profiles, standing for 105 more minutes (p=0.001) and performing 64 min more inside chores on average per day (p=0.008). Changes in sagittal plane knee range of motion (ROM) and peak knee flexion positively correlated with changes in total daily energy expenditure, time spent undertaking moderate to vigorous physical activity, inside chores and passive transport (r=0.52-0.66, p=0.005-0.047). Restoration of knee function occurs in parallel and is associated with improvements in physical activity and use of time after TKA. Increased functional knee ROM is required to support improvements in total and context specific physical activity. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.

    Science.gov (United States)

    Han, Hyuk-Soo; Kang, Seung-Baik; Jo, Chris H; Kim, Sun-Hong; Lee, Jung-Ha

    2010-10-01

    Experimental and clinical studies on the accuracy of the intramedullary alignment method have produced different results, and few have addressed accuracy in the sagittal plane. Reported deviations are not only attributable to the alignment method but also to radiological errors. The purpose of this study was to evaluate the accuracy of the intramedullary alignment method in the sagittal plane using computed tomography (CT) and 3-dimensional imaging software. Thirty-one TKAs were performed using an intramedullary alignment method involving the insertion of a long 8-mm diameter rod into the medullary canal to the distal metaphysis of the tibia. All alignment instruments were set to achieve an ideal varus/valgus angle of 0° in the coronal plane and a tibial slope of 0° in the sagittal plane. The accuracy of the intramedullary alignment system was assessed by measuring the coronal tibial component angle and sagittal tibial slope angles, i.e., angles between the tibial anatomical axis and the tangent to the medial and lateral tibial plateau or the cut-surface. The mean coronal tibial component angle was 88.5° ± 1.2° and the mean tibial component slope in the sagittal plane was 1.6° ± 1.2° without anterior slope. Our intramedullary tibial alignment method, which involves passing an 8-mm diameter long rod through the tibial shaft isthmus, showed good accuracy (less than 3 degrees of variation and no anterior slope) in the sagittal plane in neutral or varus knees.

  7. Comparison of erector spinae and hamstring muscle activities and lumbar motion during standing knee flexion in subjects with and without lumbar extension rotation syndrome.

    Science.gov (United States)

    Kim, Si-hyun; Kwon, Oh-yun; Park, Kyue-nam; Kim, Moon-Hwan

    2013-12-01

    The aim of this study was to compare the activity of the erector spinae (ES) and hamstring muscles and the amount and onset of lumbar motion during standing knee flexion between individuals with and without lumbar extension rotation syndrome. Sixteen subjects with lumbar extension rotation syndrome (10 males, 6 females) and 14 healthy subjects (8 males, 6 females) participated in this study. During the standing knee flexion, surface electromyography (EMG) was used to measure muscle activity, and surface EMG electrodes were attached to both the ES and hamstring (medial and lateral) muscles. A three-dimensional motion analysis system was used to measure kinematic data of the lumbar spine. An independent-t test was conducted for the statistical analysis. The group suffering from lumbar extension rotation syndrome exhibited asymmetric muscle activation of the ES and decreased hamstring activity. Additionally, the group with lumbar extension rotation syndrome showed greater and earlier lumbar extension and rotation during standing knee flexion compared to the control group. These data suggest that asymmetric ES muscle activation and a greater amount of and earlier lumbar motion in the sagittal and transverse plane during standing knee flexion may be an important factor contributing to low back pain. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Bracing of the Reconstructed and Osteoarthritic Knee during High Dynamic Load Tasks.

    Science.gov (United States)

    Hart, Harvi F; Crossley, Kay M; Collins, Natalie J; Ackland, David C

    2017-06-01

    Lateral compartment osteoarthritis accompanied by abnormal knee biomechanics is frequently reported in individuals with knee osteoarthritis after anterior cruciate ligament reconstruction (ACLR). The aim of this study was to evaluate changes in knee biomechanics produced by an adjusted and unadjusted varus knee brace during high dynamic loading activities in individuals with lateral knee osteoarthritis after ACLR and valgus malalignment. Nineteen participants who had undergone ACLR 5 to 20 yr previously and had symptomatic and radiographic lateral knee osteoarthritis with valgus malalignment were assessed. Quantitative motion analysis experiments were conducted during hopping, stair ascent, and descent under three test conditions: (i) no brace, (ii) unadjusted brace with sagittal plane support and neutral frontal plane alignment, and (iii) adjusted brace with sagittal plane support and varus realignment (valgus to neutral). Sagittal, frontal, and transverse plane knee kinematics, external joint moment, and angular impulse data were calculated. Relative to an unbraced knee, braced conditions significantly increased knee flexion and adduction angles during hopping (P = 0.003 and P = 0.005; respectively), stair ascent (P = 0.003 and P stair ascent (P = 0.008) and flexion moments during stair descent (P = 0.006). There were no significant differences between the adjusted and the unadjusted brace conditions (P > 0.05). A knee brace, with or without varus alignment, can modulate knee kinematics and external joint moments during hopping, stairs ascent, and descent in individuals with predominant lateral knee osteoarthritis after ACLR. Longer-term use of a brace may have implications in slowing osteoarthritis progression.

  9. Non-Sagittal Knee Joint Kinematics and Kinetics during Gait on Level and Sloped Grounds with Unicompartmental and Total Knee Arthroplasty Patients

    Science.gov (United States)

    Komnik, Igor; David, Sina; Weiss, Stefan; Potthast, Wolfgang

    2016-01-01

    After knee arthroplasty (KA) surgery, patients experience abnormal kinematics and kinetics during numerous activities of daily living. Biomechanical investigations have focused primarily on level walking, whereas walking on sloped surfaces, which is stated to affect knee kinematics and kinetics considerably, has been neglected to this day. This study aimed to analyze over-ground walking on level and sloped surfaces with a special focus on transverse and frontal plane knee kinematics and kinetics in patients with KA. A three-dimensional (3D) motion analysis was performed by means of optoelectronic stereophogrammetry 1.8 ± 0.4 years following total knee arthroplasty (TKA) and unicompartmental arthroplasty surgery (UKA). AnyBody™ Modeling System was used to conduct inverse dynamics. The TKA group negotiated the decline walking task with reduced peak knee internal rotation angles compared with a healthy control group (CG). First-peak knee adduction moments were diminished by 27% (TKA group) and 22% (UKA group) compared with the CG during decline walking. No significant differences were detected between the TKA and UKA groups, regardless of the locomotion task. Decline walking exposed apparently more abnormal knee frontal and transverse plane adjustments in KA patients than level walking compared with the CG. Hence, walking on sloped surfaces should be included in further motion analysis studies investigating KA patients in order to detect potential deficits that might be not obvious during level walking. PMID:28002437

  10. Valgus-varus motion of the knee in normal level walking and stair climbing.

    Science.gov (United States)

    Yu, B; Stuart, M J; Kienbacher, T; Growney, E S; An, K-N

    1997-07-01

    OBJECTIVE: The knee valgus-varus moment and the knee angles were compared between normal level walking and stair climbing. DESIGN: Ten healthy subjects were tested for ascent, descent, and level walking. BACKGROUND: An understanding of the normal valgus-varus motion of the knee during stair climbing is needed to apply biomechanical analysis of stair climbing as a evaluation tool for knee osteoarthritis patients. METHODS: A motion analysis system, three force plates, and a flight of stairs were used to collect kinematic and kinetic data. The knee angles and moments were calculated from the collected kinematic and kinetic data. RESULTS: The knee varus angle for the maximum knee valgus moments in stair climbing was significantly greater than that in level walking. The knee valgus moment was significantly correlated to ground reaction forces and knee valgus-varus angle during stair climbing and level walking. CONCLUSIONS: There is a coupling between the knee valgus-varus motion and flexion-extension motion. Ground reaction forces are the major contributors to the within-subject variation in the knee valgus-varus moment during stair climbing and level walking. The knee valgus-varus angle is a major contributor to the between-subject variation in the knee valgus moment during stair climbing and level walking.

  11. Knee joint contact mechanics during downhill gait and its relationship with varus/valgus motion and muscle strength in patients with knee osteoarthritis.

    Science.gov (United States)

    Farrokhi, Shawn; Voycheck, Carrie A; Gustafson, Jonathan A; Fitzgerald, G Kelley; Tashman, Scott

    2016-01-01

    The objective of this exploratory study was to evaluate tibiofemoral joint contact point excursions and velocities during downhill gait and assess the relationship between tibiofemoral joint contact mechanics with frontal-plane knee joint motion and lower extremity muscle weakness in patients with knee osteoarthritis (OA). Dynamic stereo X-ray was used to quantify tibiofemoral joint contact mechanics and frontal-plane motion during the loading response phase of downhill gait in 11 patients with knee OA and 11 control volunteers. Quantitative testing of the quadriceps and the hip abductor muscles was also performed. Patients with knee OA demonstrated larger medial/lateral joint contact point excursions (p knee OA compared to their control counterparts (p = 0.02). Additionally, patients with knee OA demonstrated significantly increased frontal-plane varus motion excursions (p knee OA were linearly associated with greater frontal-plane varus motion excursions (p knee OA may be related to compromised frontal-plane joint stability but not with deficits in muscle strength.

  12. Ankle and knee kinetics between strike patterns at common training speeds in competitive male runners.

    Science.gov (United States)

    Kuhman, Daniel; Melcher, Daniel; Paquette, Max R

    2016-01-01

    The purpose of this study was to investigate the interaction of foot strike and common speeds on sagittal plane ankle and knee joint kinetics in competitive rear foot strike (RFS) runners when running with a RFS pattern and an imposed forefoot strike (FFS) pattern. Sixteen competitive habitual male RFS runners ran at two different speeds (i.e. 8 and 6 min mile(-1)) using their habitual RFS and an imposed FFS pattern. A repeated measures analysis of variance was used to assess a potential interaction between strike pattern and speed for selected ground reaction force (GRF) variables and, sagittal plane ankle and knee kinematic and kinetic variables. No foot strike and speed interaction was observed for any of the kinetic variables. Habitual RFS yielded a greater loading rate of the vertical GRF, peak ankle dorsiflexor moment, peak knee extensor moment, peak knee eccentric extensor power, peak dorsiflexion and sagittal plane knee range of motion compared to imposed FFS. Imposed FFS yielded greater maximum vertical GRF, peak ankle plantarflexor moment, peak ankle eccentric plantarflexor power and sagittal plane ankle ROM compared to habitual RFS. Consistent with previous literature, imposed FFS in habitual RFS reduces eccentric knee extensor and ankle dorsiflexor involvement but produce greater eccentric ankle plantarflexor action compared to RFS. These acute differences between strike patterns were independent of running speeds equivalent to typical easy and hard training runs in competitive male runners. Current findings along with previous literature suggest differences in lower extremity kinetics between habitual RFS and imposed FFS running are consistent among a variety of runner populations.

  13. Lateral trunk motion and knee pain in osteoarthritis of the knee: a cross-sectional study

    NARCIS (Netherlands)

    van der Esch, M.; Steultjens, M.P.M.; Harlaar, J.; van den Noort, J.C.; Knol, D.L.; Dekker, J.

    2011-01-01

    Background: Patients with osteoarthritis of the knee may change their gait in an attempt to reduce loading of the affected knee, thereby reducing pain. Especially changes in lateral trunk motion may be potentially effective, since these will affect the position of the centre of mass relative to the

  14. Fibre recruitment and shape changes of knee ligaments during motion: as revealed by a computer graphics-based model.

    Science.gov (United States)

    Lu, T W; O'Connor, J J

    1996-01-01

    A computer graphics-based model of the knee ligaments in the sagittal plane was developed for the simulation and visualization of the shape changes and fibre recruitment process of the ligaments during motion under unloaded and loaded conditions. The cruciate and collateral ligaments were modelled as ordered arrays of fibres which link attachment areas on the tibia and femur. Fibres slacken and tighten as the ligament attachment areas on the bones rotate and translate relative to each other. A four-bar linkage, composed of the femur, tibia and selected isometric fibres of the two cruciates, was used to determine the motion of the femur relative to the tibia during passive (unloaded) movement. Fibres were assumed to slacken in a Euler buckling mode when the distances between their attachments are less than chosen reference lengths. The ligament shape changes and buckling patterns are demonstrated with computer graphics. When the tibia is translated anteriorly or posteriorly relative to the femur by muscle forces and external loads, some ligament fibres tighten and are recruited progressively to transmit increasing shear forces. The shape changes and fibre recruitment patterns predicted by the model compare well qualitatively with experimental results reported in the literature. The computer graphics approach provides insight into the micro behaviour of the knee ligaments. It may help to explain ligament injury mechanisms and provide useful information to guide the design of ligament replacements.

  15. Effect of Acute Alterations in Foot Strike Patterns during Running on Sagittal Plane Lower Limb Kinematics and Kinetics

    Directory of Open Access Journals (Sweden)

    Kevin A. Valenzuela, Scott K. Lynn, Lisa R. Mikelson, Guillermo J. Noffal, Daniel A. Judelson

    2015-03-01

    Full Text Available subjects were identified through slow motion video playback (n = 21, age = 22.8±2.2 years, mass = 73.1±14.5 kg, height 1.75 ± 0.10 m. On day two, subjects performed five overground run trials in both their natural and unnatural strike patterns while motion and force data were collected. Data were collected over two days so that foot strike videos could be analyzed for group placement purposes. Several 2 (Foot Strike Pattern –forefoot strike [FFS], rearfoot strike [RFS] x 2 (Group – PFFG, PRFG mixed model ANOVAs (p < 0.05 were run on speed, active peak vertical ground reaction force (VGRF, peak early stance and mid stance sagittal ankle moments, sagittal plane hip and knee moments, ankle dorsiflexion ROM, and sagittal plane hip and knee ROM. There were no significant interactions or between group differences for any of the measured variables. Within subject effects demonstrated that the RFS condition had significantly lower (VGRF (RFS = 2.58 ± .21 BW, FFS = 2.71 ± 0.23 BW, dorsiflexion moment (RFS = -2.6 1± 0.61 Nm·kg-1, FFS = -3.09 ± 0.32 Nm·kg-1, and dorsiflexion range of motion (RFS = 17.63 ± 3.76°, FFS = 22.10 ± 5.08°. There was also a significantly higher peak plantarflexion moment (RFS = 0.23 ± 0.11 Nm·kg-1, FFS = 0.01 ± 0.01 Nm·kg-1, peak knee moment (RFS = 2.61 ± 0.54 Nm·kg-1, FFS = 2.39 ± 0.61 Nm·kg-1, knee ROM (RFS = 31.72 ± 2.79°, FFS = 29.58 ± 2.97°, and hip ROM (RFS = 42.72 ± 4.03°, FFS = 41.38 ± 3.32° as compared with the FFS condition. This research suggests that acute changes in foot strike patterns during shod running can create alterations in certain lower limb kinematic and kinetic measures that are not dependent on the preferred foot strike pattern of the individual. This research also challenges the contention that the impact transient spike in the vertical ground reaction force curve is only present during a rear foot strike type of running gait.

  16. Kinematic alterations of the lower limbs and pelvis during an ascending stairs task are associated with the degree of knee osteoarthritis severity.

    Science.gov (United States)

    Gonçalves, Glaucia Helena; Selistre, Luiz Fernando Approbato; Petrella, Marina; Mattiello, Stela Márcia

    2017-03-01

    Individuals with knee osteoarthritis (OA) generally demonstrate great difficulty in ascending stairs. The strategies and compensations used by these individuals in stair activities have not been fully established. The purpose of this study was to investigate the joint kinematics of the pelvis, hip, knee and ankle throughout the gait cycle, in the sagittal and frontal planes, in individuals with mild and moderate knee OA, during an ascending stairs task. Thirty-one individuals with knee OA and 19 controls were subjected to clinical and radiographic analysis, divided into three groups: control, mild knee OA, and moderate knee OA. Participants answered a self-reported questionnaire, carried out performance-based tests, and their kinematic data were recorded during an ascending stairs task using an eight-camera Qualisys 3D-Motion analysis system. The individuals with moderate degrees of knee OA demonstrated kinematic alterations in the pelvis, hip, knee, and ankle in the sagittal plane. The individuals with mild degrees of knee OA demonstrated kinematic alterations of the hip in the frontal plane, and kinematic alterations of the ankle in the sagittal plane. The ascending stairs task allowed verification of meaningful information regarding gait strategies used by individuals with mild and moderate knee OA. The strategies of these two groups of individuals are different for this task, although more pronounced in individuals with moderate knee OA. The findings should be taken into account in the development of rehabilitation programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Strain measurements of the tibial insert of a knee prosthesis using a knee motion simulator.

    Science.gov (United States)

    Sera, Toshihiro; Iwai, Yuya; Yamazaki, Takaharu; Tomita, Tetsuya; Yoshikawa, Hideki; Naito, Hisahi; Matsumoto, Takeshi; Tanaka, Masao

    2017-12-01

    The longevity of a knee prosthesis is influenced by the wear of the tibial insert due to its posture and movement. In this study, we assumed that the strain on the tibial insert is one of the main reasons for its wear and investigated the influence of the knee varus-valgus angles on the mechanical stress of the tibial insert. Knee prosthesis motion was simulated using a knee motion simulator based on a parallel-link six degrees-of-freedom actuator and the principal strain and pressure distribution of the tibial insert were measured. In particular, the early stance phase obtained from in vivo X-ray images was examined because the knee is applied to the largest load during extension/flexion movement. The knee varus-valgus angles were 0° (neutral alignment), 3°, and 5° malalignment. Under a neutral orientation, the pressure was higher at the middle and posterior condyles. The first and second principal strains were larger at the high and low pressure areas, respectively. Even for a 3° malalignment, the load was concentrated at one condyle and the positive first principal strain increased dramatically at the high pressure area. The negative second principal strain was large at the low pressure area on the other condyle. The maximum equivalent strain was 1.3-2.1 times larger at the high pressure area. For a 5° malalignment, the maximum equivalent strain increased slightly. These strain and pressure measurements can provide the mechanical stress of the tibial insert in detail for determining the longevity of an artificial knee joint.

  18. 3D knee segmentation based on three MRI sequences from different planes.

    Science.gov (United States)

    Zhou, L; Chav, R; Cresson, T; Chartrand, G; de Guise, J

    2016-08-01

    In clinical practice, knee MRI sequences with 3.5~5 mm slice distance in sagittal, coronal, and axial planes are often requested for the knee examination since its acquisition is faster than high-resolution MRI sequence in a single plane, thereby reducing the probability of motion artifact. In order to take advantage of the three sequences from different planes, a 3D segmentation method based on the combination of three knee models obtained from the three sequences is proposed in this paper. In the method, the sub-segmentation is respectively performed with sagittal, coronal, and axial MRI sequence in the image coordinate system. With each sequence, an initial knee model is hierarchically deformed, and then the three deformed models are mapped to reference coordinate system defined by the DICOM standard and combined to obtain a patient-specific model. The experimental results verified that the three sub-segmentation results can complement each other, and their integration can compensate for the insufficiency of boundary information caused by 3.5~5 mm gap between consecutive slices. Therefore, the obtained patient-specific model is substantially more accurate than each sub-segmentation results.

  19. The Effect of Sagittal Plane Deformities after Tibial Plateau Fractures to Functions and Instability of Knee Joint.

    Science.gov (United States)

    Erdil, M; Yildiz, F; Kuyucu, E; Sayar, Ş; Polat, G; Ceylan, H H; Koçyiğit, F

    2016-01-01

    The objective of this study is to evaluate the effect of posterior tibial slope after fracture healing on antero-posterior knee laxity, functional outcome and patient satisfaction. 126 patients who were treated for tibial plateau fractures between 2008-2013 in the orthopedics and traumatology department of our institution were evaluated for the study. Patients were treated with open reduction and internal fixation, arthroscopy assisted minimally invasive osteosynthesis or conservative treatment. Mean posterior tibial slope after the treatment was 6.91 ± 5.11 and there was no significant difference when compared to the uninvolved side 6.42 ± 4,21 (p = 0.794). Knee laxity in anterior-posterior plane was 6.14 ± 2.11 and 5.95 ± 2.25 respectively on healthy and injured side. The difference of mean laxity in anterior-posterior plane between two sides was statistically significant. In this study we found no difference in laxity between the injured and healthy knees. However Tegner score decreased significantly in patients who had greater laxity difference between the knees. We did not find significant difference between fracture type and laxity, IKDC functional scores independent of the ligamentous injury. In conclusion despite coronal alignment is taken into consideration in treatment of tibial plateau fractures, sagittal alignment is reasonably important for stability and should not be ignored.

  20. Reliability of sagittal plane hip, knee, and ankle joint angles from a single frame of video data using the GAITRite camera system.

    Science.gov (United States)

    Ross, Sandy A; Rice, Clinton; Von Behren, Kristyn; Meyer, April; Alexander, Rachel; Murfin, Scott

    2015-01-01

    The purpose of this study was to establish intra-rater, intra-session, and inter-rater, reliability of sagittal plane hip, knee, and ankle angles with and without reflective markers using the GAITRite walkway and single video camera between student physical therapists and an experienced physical therapist. This study included thirty-two healthy participants age 20-59, stratified by age and gender. Participants performed three successful walks with and without markers applied to anatomical landmarks. GAITRite software was used to digitize sagittal hip, knee, and ankle angles at two phases of gait: (1) initial contact; and (2) mid-stance. Intra-rater reliability was more consistent for the experienced physical therapist, regardless of joint or phase of gait. Intra-session reliability was variable, the experienced physical therapist showed moderate to high reliability (intra-class correlation coefficient (ICC) = 0.50-0.89) and the student physical therapist showed very poor to high reliability (ICC = 0.07-0.85). Inter-rater reliability was highest during mid-stance at the knee with markers (ICC = 0.86) and lowest during mid-stance at the hip without markers (ICC = 0.25). Reliability of a single camera system, especially at the knee joint shows promise. Depending on the specific type of reliability, error can be attributed to the testers (e.g. lack of digitization practice and marker placement), participants (e.g. loose fitting clothing) and camera systems (e.g. frame rate and resolution). However, until the camera technology can be upgraded to a higher frame rate and resolution, and the software can be linked to the GAITRite walkway, the clinical utility for pre/post measures is limited.

  1. Correlation between hip function and knee kinematics evaluated by three-dimensional motion analysis during lateral and medial side-hopping.

    Science.gov (United States)

    Itoh, Hiromitsu; Takiguchi, Kohei; Shibata, Yohei; Okubo, Satoshi; Yoshiya, Shinichi; Kuroda, Ryosuke

    2016-09-01

    [Purpose] Kinematic and kinetic characteristics of the limb during side-hopping and hip/knee interaction during this motion have not been clarified. The purposes of this study were to examine the biomechanical parameters of the knee during side hop and analyze its relationship with clinical measurements of hip function. [Subjects and Methods] Eleven male college rugby players were included. A three-dimensional motion analysis system was used to assess motion characteristics of the knee during side hop. In addition, hip range of motion and muscle strength were evaluated. Subsequently, the relationship between knee motion and the clinical parameters of the hip was analyzed. [Results] In the lateral touchdown phase, the knee was positioned in an abducted and externally rotated position, and increasing abduction moment was applied to the knee. An analysis of the interaction between knee motion and hip function showed that range of motion for hip internal rotation was significantly correlated with external rotation angle and external rotation/abduction moments of the knee during the lateral touchdown phase. [Conclusion] Range of motion for hip internal rotation should be taken into consideration for identifying the biomechanical characteristics in the side hop test results.

  2. Auricular Acupressure for Managing Postoperative Pain and Knee Motion in Patients with Total Knee Replacement: A Randomized Sham Control Study

    Directory of Open Access Journals (Sweden)

    Ling-hua Chang

    2012-01-01

    Full Text Available Background. Postoperative pain management remains a significant challenge for all healthcare providers. A randomized controlled trial was conducted to examine the adjuvant effects of auricular acupressure on relieving postoperative pain and improving the passive range of motion in patients with total knee replacement (TKR. Method. Sixty-two patients who had undergone a TKR were randomly assigned to the acupressure group and the sham control group. The intervention was delivered three times a day for 3 days. A visual analog scale (VAS and the Short-Form McGill Pain Questionnaire were used to assess pain intensity. Pain medication consumption was recorded, and the knee motion was measured using a goniometer. Results. The patients experienced a moderately severe level of pain postoperatively (VAS 58.66 ± 20.35 while being on the routine PCA. No differences were found in pain scores between the groups at all points. However, analgesic drug usage in the acupressure group patients was significantly lower than in the sham control group (<0.05, controlling for BMI, age, and pain score. On the 3rd day after surgery, the passive knee motion in the acupressure group patients was significantly better than in the sham control group patients (<0.05, controlling for BMI. Conclusion. The application of auricular acupressure at specific therapeutic points significantly reduces the opioid analgesia requirement and improves the knee motion in patients with TKR.

  3. Sex differences in proximal control of the knee joint.

    Science.gov (United States)

    Mendiguchia, Jurdan; Ford, Kevin R; Quatman, Carmen E; Alentorn-Geli, Eduard; Hewett, Timothy E

    2011-07-01

    Following the onset of maturation, female athletes have a significantly higher risk for anterior cruciate ligament (ACL) injury compared with male athletes. While multiple sex differences in lower-extremity neuromuscular control and biomechanics have been identified as potential risk factors for ACL injury in females, the majority of these studies have focused specifically on the knee joint. However, increasing evidence in the literature indicates that lumbo-pelvic (core) control may have a large effect on knee-joint control and injury risk. This review examines the published evidence on the contributions of the trunk and hip to knee-joint control. Specifically, the sex differences in potential proximal controllers of the knee as risk factors for ACL injury are identified and discussed. Sex differences in trunk and hip biomechanics have been identified in all planes of motion (sagittal, coronal and transverse). Essentially, female athletes show greater lateral trunk displacement, altered trunk and hip flexion angles, greater ranges of trunk motion, and increased hip adduction and internal rotation during sport manoeuvres, compared with their male counterparts. These differences may increase the risk of ACL injury among female athletes. Prevention programmes targeted towards trunk and hip neuromuscular control may decrease the risk for ACL injuries.

  4. Sex Differences in Proximal Control of the Knee Joint

    Science.gov (United States)

    Mendiguchia, Jurdan; Ford, Kevin R.; Quatman, Carmen E.; Alentorn-Geli, Eduard; Hewett, Timothy E.

    2014-01-01

    Following the onset of maturation, female athletes have a significantly higher risk for anterior cruciate ligament (ACL) injury compared with male athletes. While multiple sex differences in lower-extremity neuromuscular control and biomechanics have been identified as potential risk factors for ACL injury in females, the majority of these studies have focused specifically on the knee joint. However, increasing evidence in the literature indicates that lumbopelvic (core) control may have a large effect on knee-joint control and injury risk. This review examines the published evidence on the contributions of the trunk and hip to knee-joint control. Specifically, the sex differences in potential proximal controllers of the knee as risk factors for ACL injury are identified and discussed. Sex differences in trunk and hip biomechanics have been identified in all planes of motion (sagittal, coronal and transverse). Essentially, female athletes show greater lateral trunk displacement, altered trunk and hip flexion angles, greater ranges of trunk motion, and increased hip adduction and internal rotation during sport manoeuvres, compared with their male counterparts. These differences may increase the risk of ACL injury among female athletes. Prevention programmes targeted towards trunk and hip neuromuscular control may decrease the risk for ACL injuries. PMID:21688868

  5. Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor

    Directory of Open Access Journals (Sweden)

    Malchau Henrik

    2006-09-01

    Full Text Available Abstract Background There is currently a paucity of devices available for continuous, long-term monitoring of human joint motion. Non-invasive, inexpensive devices capable of recording human activity and joint motion have many applications for medical research. Such a device could be used to quantify range of motion outside the gait laboratory. The purpose of this study was to test the accuracy of the modified Intelligent Device for Energy Expenditure and Activity (IDEEA in measuring knee flexion angles, to detect different physical activities, and to quantify how often healthy subjects use deep knee flexion in the ambulatory setting. Methods We compared Biomotion Laboratory (BML "gold standard" data to simultaneous IDEEA measures of knee motion and gait, step up/down, and stair descent in 5 healthy subjects. In addition, we used a series of choreographed physical activities outside the BML to confirm the IDEEA's ability to accurately measure 7 commonly-performed physical activities. Subjects then continued data collection during ordinary activities outside the gait laboratory. Results Pooled correlations between the BML and IDEEA knee flexion angles were .97 +/- .03 for step up/down, .98 +/- .02 for stair descent, and .98 +/- .01 for gait. In the BML protocol, the IDEEA accurately identified gait, but was less accurate in identifying step up/down and stair descent. During sampling outside the BML, the IDEEA accurately detected walking, running, stair ascent, stair descent, standing, lying, and sitting. On average, subjects flexed their knees >120° for 0.17% of their data collection periods outside the BML. Conclusion The modified IDEEA system is a useful clinical tool for evaluating knee motion and multiple physical activities in the ambulatory setting. These five healthy subjects rarely flexed their knees >120°.

  6. Comparison of 2D-3D Measurements of Hallux and First Ray Sagittal Motion in Patients With and Without Hallux Valgus.

    Science.gov (United States)

    Swanson, Jessica E; Stoltman, Matthew G; Oyen, Cheyenne R; Mohrbacher, Jessica A; Orandi, Atefeh; Olson, Jeff M; Glasoe, Ward M

    2016-02-01

    Clinicians base treatment decisions on measures of hallux and first ray motion in the management of first metatarsophalangeal joint disorders. Women account for a majority of the patients. This study assessed the reliability of a 2D approach for the measurements of sagittal motion, and compared the result to a Cardan (3D) angle criterion standard and evaluated how hallux valgus (bunion) deformity affected the comparisons. Twenty-nine women (controls n = 10; bunion n = 19) were examined using a retrospective repeated measures design. Weightbearing magnetic resonance (MR) images were acquired to replicate the position of the foot during the stance phase of gait. The images were reconstructed into virtual bone models using computer processes, whereby measures of hallux and first ray motion were represented by 2D and 3D methods of measurement. An examiner measured 2D motion on the image data sets using a goniometer, and reliability was assessed. The 3D Cardan angle result was derived from a matrix calculation. The 2D-3D comparison of measurements was evaluated with an analysis of variance (ANOVA) model across gait conditions, run separate for groups. The 2D measurement was reliable (ICC ≥ 0.98, SEM ≤ 0.89 degrees). There was no method-by-condition interaction (F ≤ 1.37, P ≥ .25) between variables. No significant difference was detected between the 2D-3D measurements in the control group (F ≤ 1.24, P ≥ .30), but the measurements were statistically different (F ≥ 4.46, P ≤ .049) in the bunion group. This study described a reliable 2D approach for measuring hallux and first ray sagittal motion from weightbearing images. The 2D measurements were comparable to a Cardan angle component motion result in controls, but not in women with bunion. Joint motion measurements may augment clinical decision making. These results suggest that a 2D image-based approach may be adequate to estimate hallux and first ray sagittal motion, although bunion deformity creates out

  7. Observer-Based Human Knee Stiffness Estimation.

    Science.gov (United States)

    Misgeld, Berno J E; Luken, Markus; Riener, Robert; Leonhardt, Steffen

    2017-05-01

    We consider the problem of stiffness estimation for the human knee joint during motion in the sagittal plane. The new stiffness estimator uses a nonlinear reduced-order biomechanical model and a body sensor network (BSN). The developed model is based on a two-dimensional knee kinematics approach to calculate the angle-dependent lever arms and the torques of the muscle-tendon-complex. To minimize errors in the knee stiffness estimation procedure that result from model uncertainties, a nonlinear observer is developed. The observer uses the electromyogram (EMG) of involved muscles as input signals and the segmental orientation as the output signal to correct the observer-internal states. Because of dominating model nonlinearities and nonsmoothness of the corresponding nonlinear functions, an unscented Kalman filter is designed to compute and update the observer feedback (Kalman) gain matrix. The observer-based stiffness estimation algorithm is subsequently evaluated in simulations and in a test bench, specifically designed to provide robotic movement support for the human knee joint. In silico and experimental validation underline the good performance of the knee stiffness estimation even in the cases of a knee stiffening due to antagonistic coactivation. We have shown the principle function of an observer-based approach to knee stiffness estimation that employs EMG signals and segmental orientation provided by our own IPANEMA BSN. The presented approach makes realtime, model-based estimation of knee stiffness with minimal instrumentation possible.

  8. Markerless motion capture can provide reliable 3D gait kinematics in the sagittal and frontal plane

    DEFF Research Database (Denmark)

    Sandau, Martin; Koblauch, Henrik; Moeslund, Thomas B.

    2014-01-01

    Estimating 3D joint rotations in the lower extremities accurately and reliably remains unresolved in markerless motion capture, despite extensive studies in the past decades. The main problems have been ascribed to the limited accuracy of the 3D reconstructions. Accordingly, the purpose of the pr......Estimating 3D joint rotations in the lower extremities accurately and reliably remains unresolved in markerless motion capture, despite extensive studies in the past decades. The main problems have been ascribed to the limited accuracy of the 3D reconstructions. Accordingly, the purpose...... subjects in whom hip, knee and ankle joint were analysed. Flexion/extension angles as well as hip abduction/adduction closely resembled those obtained from the marker based system. However, the internal/external rotations, knee abduction/adduction and ankle inversion/eversion were less reliable....

  9. Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat

    DEFF Research Database (Denmark)

    Ageberg, Eva; Bennell, Kim L; Hunt, Michael A

    2010-01-01

    Muscle function may influence the risk of knee injury and outcomes following injury. Clinical tests, such as a single-limb mini squat, resemble conditions of daily life and are easy to administer. Fewer squats per 30 seconds indicate poorer function. However, the quality of movement, such as the ......, such as the medio-lateral knee motion may also be important. The aim was to validate an observational clinical test of assessing the medio-lateral knee motion, using a three-dimensional (3-D) motion analysis system. In addition, the inter-rater reliability was evaluated....

  10. Is digital photography an accurate and precise method for measuring range of motion of the hip and knee?

    Science.gov (United States)

    Russo, Russell R; Burn, Matthew B; Ismaily, Sabir K; Gerrie, Brayden J; Han, Shuyang; Alexander, Jerry; Lenherr, Christopher; Noble, Philip C; Harris, Joshua D; McCulloch, Patrick C

    2017-09-07

    Accurate measurements of knee and hip motion are required for management of musculoskeletal pathology. The purpose of this investigation was to compare three techniques for measuring motion at the hip and knee. The authors hypothesized that digital photography would be equivalent in accuracy and show higher precision compared to the other two techniques. Using infrared motion capture analysis as the reference standard, hip flexion/abduction/internal rotation/external rotation and knee flexion/extension were measured using visual estimation, goniometry, and photography on 10 fresh frozen cadavers. These measurements were performed by three physical therapists and three orthopaedic surgeons. Accuracy was defined by the difference from the reference standard, while precision was defined by the proportion of measurements within either 5° or 10°. Analysis of variance (ANOVA), t-tests, and chi-squared tests were used. Although two statistically significant differences were found in measurement accuracy between the three techniques, neither of these differences met clinical significance (difference of 1.4° for hip abduction and 1.7° for the knee extension). Precision of measurements was significantly higher for digital photography than: (i) visual estimation for hip abduction and knee extension, and (ii) goniometry for knee extension only. There was no clinically significant difference in measurement accuracy between the three techniques for hip and knee motion. Digital photography only showed higher precision for two joint motions (hip abduction and knee extension). Overall digital photography shows equivalent accuracy and near-equivalent precision to visual estimation and goniometry.

  11. Validity and inter-rater reliability of medio-lateral knee motion observed during a single-limb mini squat

    Directory of Open Access Journals (Sweden)

    Simic Milena

    2010-11-01

    Full Text Available Abstract Background Muscle function may influence the risk of knee injury and outcomes following injury. Clinical tests, such as a single-limb mini squat, resemble conditions of daily life and are easy to administer. Fewer squats per 30 seconds indicate poorer function. However, the quality of movement, such as the medio-lateral knee motion may also be important. The aim was to validate an observational clinical test of assessing the medio-lateral knee motion, using a three-dimensional (3-D motion analysis system. In addition, the inter-rater reliability was evaluated. Methods Twenty-five (17 women non-injured participants (mean age 25.6 years, range 18-37 were included. Visual analysis of the medio-lateral knee motion, scored as knee-over-foot or knee-medial-to-foot by two raters, and 3-D kinematic data were collected simultaneously during a single-limb mini squat. Frontal plane 2-D peak tibial, thigh, and knee varus-valgus angles, and 3-D peak hip internal-external rotation, and knee varus-valgus angles were calculated. Results Ten subjects were scored as having a knee-medial-to-foot position and 15 subjects a knee-over-foot position assessed by visual inspection. In 2-D, the peak tibial angle (mean 89.0 (SE 0.7 vs mean 86.3 (SE 0.4 degrees, p = 0.001 and peak thigh angle (mean 77.4 (SE 1.0 vs mean 81.2 (SE 0.5 degrees, p = 0.001 with respect to the horizontal, indicated that the knee was more medially placed than the ankle and thigh, respectively. Thus, the knee was in more valgus (mean 11.6 (SE 1.5 vs 5.0 (SE 0.8 degrees, p 0.90 and 96 between raters. Conclusions Medio-lateral motion of the knee can reliably be assessed during a single-leg mini-squat. The test is valid in 2-D, while the actual movement, in 3-D, is mainly exhibited as increased internal hip rotation. The single-limb mini squat is feasible and easy to administer in the clinical setting and in research to address lower extremity movement quality.

  12. Technical feasibility of personalized articulating knee joint distraction for treatment of tibiofemoral osteoarthritis.

    Science.gov (United States)

    Struik, T; Jaspers, J E N; Besselink, N J; van Roermund, P M; Plomp, S; Rudert, M J; Lafeber, F P J G; Mastbergen, S C

    2017-11-01

    Knee osteoarthritis is a highly prevalent degenerative joint disorder characterized by joint tissue damage and pain. Knee joint distraction has been introduced as a joint preserving surgical procedure to postpone knee arthroplasty. An often used standard externally fixation device for distraction poses a burden to patients due to the absence of joint flexion during the 6weeks treatment. Therefore, a personalized articulating distraction device was developed. The aim of this study was to test technical feasibility of this device. Based on an often applied rigid device, using equal bone pin positions and connectors, a hinge mechanism was developed consisting of a cam-following system for reproducing the complex joint-specific knee kinematics. In support, a device was developed for capturing the joint-specific sagittal plane articulation. The obtained kinematic data were translated into joint-specific cam shapes that were installed bilaterally in the hinge mechanism of the distraction device, as such providing personalized knee motion. Distraction of 5mm was performed within a range of motion of 30deg. joint flexion. Pre-clinical evaluation of the working principle was performed on human cadaveric legs and system stiffness characteristics were biomechanically evaluated. The desired range of motion was obtained and distraction was maintained under physiologically representative loading. Moreover, the joint-specific approach demonstrated tolerance of deviations from anatomical and alignment origin during initial placement of the developed distraction device. Articulation during knee distraction is considered technically feasible and has potential to decrease burden and improve acceptance of distraction therapy. Testing of clinical feasibility is warranted. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Effects of changing speed on knee and ankle joint load during walking and running.

    Science.gov (United States)

    de David, Ana Cristina; Carpes, Felipe Pivetta; Stefanyshyn, Darren

    2015-01-01

    Joint moments can be used as an indicator of joint loading and have potential application for sports performance and injury prevention. The effects of changing walking and running speeds on joint moments for the different planes of motion still are debatable. Here, we compared knee and ankle moments during walking and running at different speeds. Data were collected from 11 recreational male runners to determine knee and ankle joint moments during different conditions. Conditions include walking at a comfortable speed (self-selected pacing), fast walking (fastest speed possible), slow running (speed corresponding to 30% slower than running) and running (at 4 m · s(-1) ± 10%). A different joint moment pattern was observed between walking and running. We observed a general increase in joint load for sagittal and frontal planes as speed increased, while the effects of speed were not clear in the transverse plane moments. Although differences tend to be more pronounced when gait changed from walking to running, the peak moments, in general, increased when speed increased from comfortable walking to fast walking and from slow running to running mainly in the sagittal and frontal planes. Knee flexion moment was higher in walking than in running due to larger knee extension. Results suggest caution when recommending walking over running in an attempt to reduce knee joint loading. The different effects of speed increments during walking and running should be considered with regard to the prevention of injuries and for rehabilitation purposes.

  14. Reliable sagittal plane kinematic gait assessments are feasible using low-cost webcam technology.

    Science.gov (United States)

    Saner, Robert J; Washabaugh, Edward P; Krishnan, Chandramouli

    2017-07-01

    Three-dimensional (3-D) motion capture systems are commonly used for gait analysis because they provide reliable and accurate measurements. However, the downside of this approach is that it is expensive and requires technical expertise; thus making it less feasible in the clinic. To address this limitation, we recently developed and validated (using a high-precision walking robot) a low-cost, two-dimensional (2-D) real-time motion tracking approach using a simple webcam and LabVIEW Vision Assistant. The purpose of this study was to establish the repeatability and minimal detectable change values of hip and knee sagittal plane gait kinematics recorded using this system. Twenty-one healthy subjects underwent two kinematic assessments while walking on a treadmill at a range of gait velocities. Intraclass correlation coefficients (ICC) and minimal detectable change (MDC) values were calculated for commonly used hip and knee kinematic parameters to demonstrate the reliability of the system. Additionally, Bland-Altman plots were generated to examine the agreement between the measurements recorded on two different days. The system demonstrated good to excellent reliability (ICC>0.75) for all the gait parameters tested on this study. The MDC values were typically low (gait assessments using webcam technology can be reliably used for clinical and research purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Spinal sagittal balance substantially influences locomotive syndrome and physical performance in community-living middle-aged and elderly women.

    Science.gov (United States)

    Muramoto, Akio; Imagama, Shiro; Ito, Zenya; Hirano, Kenichi; Ishiguro, Naoki; Hasegawa, Yukiharu

    2016-03-01

    Spinal sagittal imbalance has been well known risk factor of decreased quality of life in the field of adult spinal deformity. However, the impact of spinal sagittal balance on locomotive syndrome and physical performance in community-living elderly has not yet been clarified. The present study investigated the influence of spinal sagittal alignment on locomotive syndrome (LS) and physical performance in community-living middle-aged and elderly women. A total of 125 women between the age of 40-88 years (mean 66.2 ± 9.7 years) who completed the questionnaires, spinal mouse test, physical examination and physical performance tests in Yakumo study were enrolled in this study. Participants answered the 25-Question Geriatric Locomotive Function Scale (GLFS-25), the visual analog scale (VAS) for low back pain (LBP), knee pain. LS was defined as having a score of >16 points on the GLFS-25. Using spinal mouse, spinal inclination angle (SIA), thoracic kyphosis angle (TKA), lumbar lordosis angle (LLA), sacral slope angle (SSA), thoracic spinal range of motion (TSROM), lumbar spinal range of motion (LSROM) were measured. Timed-up-and-go test (TUG), one-leg standing time with eyes open (OLS), and maximum stride, back muscle strength were also measured. The relationship between spinal sagittal parameters and GLFS-25, VAS and physical performance tests were analyzed. 26 people were diagnosed as LS and 99 were diagnosed as non-LS. LBP and knee pain were greater, physical performance tests were poorer, SIA were greater, LLA were smaller in LS group compared to non-LS group even after adjustment by age. SIA significantly correlated with GLFS-25, TUG, OLS and maximum stride even after adjustment by age. The cutoff value of SIA for locomotive syndrome was 6°. People with a SIA of 6° or greater were grouped as "Inclined" and people with a SIA of less than 6° were grouped as "Non-inclined". 21 people were "Inclined" and 104 were "Non-inclined". Odds ratio to fall in LS of

  16. The effects of the sagittal plane malpositioning of the patella and concomitant quadriceps hypotrophy on the patellofemoral joint: a finite element analysis.

    Science.gov (United States)

    Aksahin, Ertugrul; Kocadal, Onur; Aktekin, Cem N; Kaya, Defne; Pepe, Murad; Yılmaz, Serdar; Yuksel, H Yalcin; Bicimoglu, Ali

    2016-03-01

    Anterior knee pain is a common symptom after intramedullary nailing in tibia shaft fracture. Moreover, patellofemoral malalignment is also known to be a major reason for anterior knee pain. Patellofemoral malalignment predisposes to increased loading in patellar cartilage. In the previous study, we have demonstrated the quadriceps atrophy and patellofemoral malalignment after intramedullary nailing due to tibia shaft fracture. In this study, our aim was to clarify the effects of quadriceps atrophy and patellofemoral malalignment with the pathologic loading on the joint cartilage. Mesh models of patellofemoral joint were constructed with CT images and integrated with soft tissue components such as menisci and ligaments. Physiological and sagittal tilt models during extension and flexion at 15°, 30° and 60° were created generating eight models. All the models were applied with 137 N force to present the effects of normal loading and 115.7 N force for the simulation of quadriceps atrophy. Different degrees of loading were applied to evaluate the joint contact area and pressure value with the finite element analysis. There was increased patellofemoral contact area in patellar tilt models with respect to normal models. The similar loading patterns were diagnosed in all models at 0° and 15° knee flexion when 137 N force was applied. Higher loading values were obtained at 30° and 60° knee flexions in sagittal tilt models. Furthermore, in the sagittal tilt models, in which the quadriceps atrophy was simulated, the loadings at 30° and 60° knee flexion were higher than in the physiological ones. Sagittal malalignment of the patellofemoral joint is a new concept that results in different loading patterns in the patellofemoral joint biomechanics. This malalignment in sagittal plane leads to increased loading values on the patellofemoral joint at 30° and 60° of the knee flexions. This new concept should be kept in mind during the course of diagnosis and treatment

  17. Relationships between the center of pressure and the movements of the ankle and knee joints during the stance phase in patients with severe medial knee osteoarthritis.

    Science.gov (United States)

    Fukaya, Takashi; Mutsuzaki, Hirotaka; Okubo, Tomoyuki; Mori, Koichi; Wadano, Yasuyoshi

    2016-08-01

    The knee joint movement during the stance phase is affected by altered ankle movement and the center of pressure (COP). However the relationships between changes in the center of pressure (COP) and the altered kinematics and kinetics of the ankle and knee joints in patients with osteoarthritis (OA) of the knee are not well understood. The purpose of this study was to determine the relationships between changes in the COP and the altered kinematic and kinetic variables in ankle and knee joints during the stance phase in patients with medial knee OA. Fourteen patients with knee OA (21 knees) and healthy subjects were assessed by gait analysis using an eight-camera motion analysis system to record forward and lateral shifts in the COP and the angle and net internal moments of the knee and ankle joint. Spearman rank-correlation coefficients were used to determine the relationship between these results. In knees with medial OA, lateral shifts in the COP were correlated with knee flexion angle. Lateral shifts in the COP were correlated with the second peak of the knee extensor moment and correlated with the knee abductor moment. In patients with medial knee OA, lateral shifts in the COP were negatively correlated with the kinematic and kinetic variables in the sagittal plane of the knee joints. Controlling such lateral shifts in the COP may thus be an effective intervention for mechanical loads on the knee during the stance phase in patients with knee OA. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. The wrinkled patellar tendon: An indication of abnormality in the extensor mechanism of the knee

    International Nuclear Information System (INIS)

    Berlin, R.C.; Levinsohn, E.M.; Chrisman, H.

    1991-01-01

    Rupture of the quadriceps tendon is an uncommon condition which requires early diagnosis and treatment to avert prolonged disability. In four patients who had surgically confirmed quadriceps tendon rupture, lateral radiographs of the knee and/or sagittal magnetic resonance (MR) images demonstrated a corrugated appearance to the patellar tendon. Sagittal MR images of the knee following patellectomy in one patient and radiographs of a transverse fracture of the patella in another also demonstrated this appearance. MRI has superb contrast resolution which provides optimal visualization of the contour of the patellar tendon on sagittal images. A retrospective review of 50 consecutive knee MRI examinations was carried out to evaluate the appearance of the normal patellar tendon. In 49 of 50 patients, the sagittal images demonstrated a straight or nearly straight patellar tendon. A corrugated appearance of the patellar tendon on sagittal images indicates a reduction in the normal tensile force applied to it and indicates the need for careful evaluation of the patella and quadriceps tendon mechanism. (orig.)

  19. Clinical outcome of increased flexion gap after total knee arthroplasty. Can controlled gap imbalance improve knee flexion?

    Science.gov (United States)

    Ismailidis, P; Kuster, M S; Jost, B; Giesinger, K; Behrend, H

    2017-06-01

    Increased range of motion (ROM) while maintaining joint stability is the goal of modern total knee arthroplasty (TKA). A biomechanical study has shown that small increases in flexion gap result in decreased tibiofemoral force beyond 90° flexion. The purpose of this paper was to investigate clinical implications of controlled increased flexion gap. Four hundred and four TKAs were allocated into one of two groups and analysed retrospectively. In the first group (n = 352), flexion gap exceeded extension gap by 2.5 mm, while in the second group (n = 52) flexion gap was equal to the extension gap. The procedures were performed from 2008 to 2012. The patients were reviewed 12 months postoperatively. Objective clinical results were assessed for ROM, mediolateral and sagittal stability. Patient-reported outcome measures were the WOMAC score and the Forgotten Joint Score (FJS-12). After categorizing postoperative flexion into three groups (poor < 90°, satisfactory 91°-119°, good ≥ 120°) significantly more patients in group 1 achieved satisfactory or good ROM (p = 0.006). Group 1 also showed a significantly higher mean FJS-12 (group 1: 73, group 2: 61, p = 0.02). The mean WOMAC score was 11 in the first and 14 in the second group (n.s.). Increase in flexion gap did not influence knee stability. The clinical relevance of this study is that a controlled flexion gap increase of 2.5 mm may have a positive effect on postoperative flexion and patient satisfaction after TKA. Neither knee stability in the coronal and sagittal planes nor complications were influenced by a controlled increase in flexion gap. III.

  20. Knee Kinematic Improvement After Total Knee Replacement Using a Simplified Quantitative Gait Analysis Method

    Directory of Open Access Journals (Sweden)

    Hassan Sarailoo

    2013-10-01

    Full Text Available Objectives: The aim of this study was to extract suitable spatiotemporal and kinematic parameters to determine how Total Knee Replacement (TKR alters patients’ knee kinematics during gait, using a rapid and simplified quantitative two-dimensional gait analysis procedure. Methods: Two-dimensional kinematic gait pattern of 10 participants were collected before and after the TKR surgery, using a 60 Hz camcorder in sagittal plane. Then, the kinematic parameters were extracted using the gait data. A student t-test was used to compare the group-average of spatiotemporal and peak kinematic characteristics in the sagittal plane. The knee condition was also evaluated using the Oxford Knee Score (OKS Questionnaire to ensure thateach subject was placed in the right group. Results: The results showed a significant improvement in knee flexion during stance and swing phases after TKR surgery. The walking speed was increased as a result of stride length and cadence improvement, but this increment was not statistically significant. Both post-TKR and control groups showed an increment in spatiotemporal and peak kinematic characteristics between comfortable and fast walking speeds. Discussion: The objective kinematic parameters extracted from 2D gait data were able to show significant improvements of the knee joint after TKR surgery. The patients with TKR surgery were also able to improve their knee kinematics during fast walking speed equal to the control group. These results provide a good insight into the capabilities of the presented method to evaluate knee functionality before and after TKR surgery and to define a more effective rehabilitation program.

  1. A flexible wearable sensor for knee flexion assessment during gait.

    Science.gov (United States)

    Papi, Enrica; Bo, Yen Nee; McGregor, Alison H

    2018-05-01

    Gait analysis plays an important role in the diagnosis and management of patients with movement disorders but it is usually performed within a laboratory. Recently interest has shifted towards the possibility of conducting gait assessments in everyday environments thus facilitating long-term monitoring. This is possible by using wearable technologies rather than laboratory based equipment. This study aims to validate a novel wearable sensor system's ability to measure peak knee sagittal angles during gait. The proposed system comprises a flexible conductive polymer unit interfaced with a wireless acquisition node attached over the knee on a pair of leggings. Sixteen healthy volunteers participated to two gait assessments on separate occasions. Data was simultaneously collected from the novel sensor and a gold standard 10 camera motion capture system. The relationship between sensor signal and reference knee flexion angles was defined for each subject to allow the transformation of sensor voltage outputs to angular measures (degrees). The knee peak flexion angle from the sensor and reference system were compared by means of root mean square error (RMSE), absolute error, Bland-Altman plots and intra-class correlation coefficients (ICCs) to assess test-retest reliability. Comparisons of knee peak flexion angles calculated from the sensor and gold standard yielded an absolute error of 0.35(±2.9°) and RMSE of 1.2(±0.4)°. Good agreement was found between the two systems with the majority of data lying within the limits of agreement. The sensor demonstrated high test-retest reliability (ICCs>0.8). These results show the ability of the sensor to monitor knee peak sagittal angles with small margins of error and in agreement with the gold standard system. The sensor has potential to be used in clinical settings as a discreet, unobtrusive wearable device allowing for long-term gait analysis. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  2. Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position.

    Science.gov (United States)

    Cho, Kang Hee; Jeon, Yumi; Lee, Hyunkeun

    2016-04-01

    To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint.

  3. Patient Self-Assessed Passive Range of Motion of the Knee Cannot Replace Health Professional Measurements

    DEFF Research Database (Denmark)

    Borgbjerg, Jens; Madsen, Frank; Odgaard, Anders

    2017-01-01

    The purpose of this study was to investigate whether patients can accurately self-assess their knee passive range of motion (PROM). A picture-based questionnaire for patient self-assessment of knee PROM was developed and posted to patients. The self-assessed PROM from 58 patients was compared...... (≥ 10-degree flexion contracture). Surgeon- and patient-assessed knee PROM showed a mean difference (95% limits of agreement) of -2.1 degrees (-42.5 to 38.3 degrees) for flexion and -8.1 degrees (-28.8 to 12.7 degrees) for extension. The sensitivity of patient self-assessed PROM in identifying knee...

  4. Ground reaction forces and knee kinetics during single and repeated badminton lunges.

    Science.gov (United States)

    Lam, Wing Kai; Ding, Rui; Qu, Yi

    2017-03-01

    Repeated movement (RM) lunge that frequently executed in badminton might be used for footwear evaluation. This study examined the influence of single movement (SM) and RM lunges on the ground reaction forces (GRFs) and knee kinetics during the braking phase of a badminton lunge step. Thirteen male university badminton players performed left-forward lunges in both SM and RM sessions. Force platform and motion capturing system were used to measure GRFs and knee kinetics variables. Paired t-test was performed to determine any significant differences between SM and RM lunges regarding mean and coefficient of variation (CV) in each variable. The kinetics results indicated that compared to SM lunges, the RM lunges had shorter contact time and generated smaller maximum loading rate of impact force, peak knee anterior-posterior force, and peak knee sagittal moment but generated larger peak horizontal resultant forces (Ps < 0.05). Additionally, the RM lunges had lower CV for peak knee medial-lateral and vertical forces (Ps < 0.05). These results suggested that the RM testing protocols had a distinct loading response and adaptation pattern during lunge and that the RM protocol showed higher within-trial reliability, which may be beneficial for the knee joint loading evaluation under different interventions.

  5. Smartphone Photography as a Tool to Measure Knee Range of Motion.

    Science.gov (United States)

    Mica, Megan Conti; Wagner, Eric R; Shin, Alexander Y

    2018-01-01

    The objective of this study was to validate measuring knee range of motion (ROM) from smartphone photography. Thirty-two participants (64 knees) obtained smartphone photographs of knee flexion and extension. Surgeons obtained the same photographs and goniometric measurement of ROM. ROM was measured using Adobe Photoshop. Goniometer versus digital measurements, participant versus surgeon photographs, and interobserver measurements were analyzed. The average difference in goniometer and digital photograph measurements was 5°. The interclass correlation was .642(L) and .656(R). The Bland-Altman plots demonstrated that 29/32 digital measurements were within the 95% confidence interval (CI). Participants' versus researchers' photographs averaged a 2° difference. The interclass correlation was .924(L) and .91(R). Bland-Altman plots demonstrated that 31/32 measurements were within the 95% CI. Interobserver reliability averaged aROMdifference of 5°. The concordance coefficients were .647(L) and .723(R). Bland-Altman plots demonstrated that 30 of 32 digital measurements were within the 95% CI. Measuring knee ROM using smartphone digital photography is valid and reliable. (Journal of Surgical Orthopaedic Advances 27(1):52-57, 2018).

  6. Effects of Fatigue on Frontal Plane Knee Motion, Muscle Activity, and Ground Reaction Forces In Men and Women During Landing

    OpenAIRE

    Smith, Michael P.; Sizer, Phillip S.; James, C. Roger

    2009-01-01

    Women tear their Anterior Cruciate Ligament (ACL) 2-8 times more frequently than men. Frontal plane knee motion can produce a pathological load in the ACL. During a state of fatigue the muscles surrounding the knee joint may lose the ability to protect the joint during sudden deceleration while landing. The purpose of this study was to investigate the effects of fatigue and gender on frontal plane knee motion, EMG amplitudes, and GRF magnitudes during drop- jump landing. Pretest-posttest comp...

  7. Helical axes of skeletal knee joint motion during running.

    Science.gov (United States)

    van den Bogert, A J; Reinschmidt, C; Lundberg, A

    2008-01-01

    The purpose of this study was to determine the changes in the axis of rotation of the knee that occur during the stance phase of running. Using intracortical pins, the three-dimensional skeletal kinematics of three subjects were measured during the stance phase of five running trials. The stance phase was divided into equal motion increments for which the position and orientation of the finite helical axes (FHA) were calculated relative to a tibial reference frame. Results were consistent within and between subjects. At the beginning of stance, the FHA was located at the midepicondylar point and during the flexion phase moved 20mm posteriorly and 10mm distally. At the time of peak flexion, the FHA shifted rapidly by about 10-20mm in proximal and posterior direction. The angle between the FHA and the tibial transverse plane increased gradually during flexion, to about 15 degrees of medial inclination, and then returned to zero at the start of the extension phase. These changes in position and orientation of FHA in the knee should be considered in analyses of muscle function during human movement, which require moment arms to be defined relative to a functional rotation axis. The finding that substantial changes in axis of rotation occurred independent of flexion angle suggests that musculoskeletal models must have more than one kinematic degree-of-freedom at the knee. The same applies to the design of knee prostheses, if the goal is to restore normal muscle function.

  8. Gait adaptations with aging in healthy participants and people with knee-joint osteoarthritis.

    Science.gov (United States)

    Duffell, Lynsey D; Jordan, Stevan J; Cobb, Justin P; McGregor, Alison H

    2017-09-01

    The relationship between age and gait characteristics in people with and without medial compartment osteoarthritis (OA) remains unclear. We aimed to characterize this relationship and to relate biomechanical and structural parameters in a subset of OA patients. Twenty five participants with diagnosed unilateral medial knee OA and 84 healthy participants, with no known knee pathology were recruited. 3D motion capture was used to analyse sagittal and coronal plane gait parameters while participants walked at a comfortable speed. Participants were categorized according to age (18-30, 31-59 and 60+ years), and those with and without OA were compared between and within age groups. In a subset of OA patients, clinically available Computed Tomography images were used to assess joint structure. Differences in coronal plane kinematics at the hip and knee were noted in participants with OA particularly those who were older compared with our healthy controls, as well as increased knee moments. Knee adduction moment correlated with structural parameters in the subset of OA patients. Increased knee moments and altered kinematics were observed in older participants presenting with OA only, which seem to be related to morphological changes in the joint due to OA, as opposed to being related to the initial cause of medial knee OA. Copyright © 2017. Published by Elsevier B.V.

  9. Slightly flexed knee position within a standard knee coil: MR delineation of the anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, M.; Itai, Y. [Department of Radiology, Institute of Clinical Medicine, University of Tsukuba, Tennodai, Tsukuba, Ibaraki 305 (Japan); Ikeda, K. [Department of Orthopedic Surgery, Institute of Clinical Medicine, University of Tsukuba, Tennodai, Tsukuba, Ibaraki 305 (Japan)

    1998-02-01

    The purpose of this study was to assess the value of positioning the knee slightly flexed within a standard MR knee coil in delineation of the anterior cruciate ligament (ACL). Within the confined space of a commercially available knee coil, knee could bend as much as 30 , average 17 of flexion. Sets of oblique sagittal MR images were obtained at both fully extended and slightly flexed positions. Twenty-two normal knees and 18 knees with ACL tears were examined and paired MR images were evaluated by two observers. Compared with knee extension, the MR images for knee flexion provided better clarity in 57 % of reviews of full length of the ACL and 53 % of the femoral attachment. In the extended position the anterior margin of the ligament was obscured due to partial averaging with the intercondylar roof. We recommend examining the knee in an achievable flexed position within the standard knee coil. (orig.) With 3 figs., 1 tab., 6 refs.

  10. Slightly flexed knee position within a standard knee coil: MR delineation of the anterior cruciate ligament

    International Nuclear Information System (INIS)

    Niitsu, M.; Itai, Y.; Ikeda, K.

    1998-01-01

    The purpose of this study was to assess the value of positioning the knee slightly flexed within a standard MR knee coil in delineation of the anterior cruciate ligament (ACL). Within the confined space of a commercially available knee coil, knee could bend as much as 30 , average 17 of flexion. Sets of oblique sagittal MR images were obtained at both fully extended and slightly flexed positions. Twenty-two normal knees and 18 knees with ACL tears were examined and paired MR images were evaluated by two observers. Compared with knee extension, the MR images for knee flexion provided better clarity in 57 % of reviews of full length of the ACL and 53 % of the femoral attachment. In the extended position the anterior margin of the ligament was obscured due to partial averaging with the intercondylar roof. We recommend examining the knee in an achievable flexed position within the standard knee coil. (orig.)

  11. Evaluation of knee range of motion: Correlation between measurements using a universal goniometer and a smartphone goniometric application.

    Science.gov (United States)

    Dos Santos, Rafael Aparecido; Derhon, Viviane; Brandalize, Michelle; Brandalize, Danielle; Rossi, Luciano Pavan

    2017-07-01

    Goniometers are commonly used to measure range of motion in the musculoskeletal system. Recently smartphone goniometry applications have become available to clinicians. Compare angular measures using a universal goniometer and a smartphone application. Thirty four healthy women with at least 20° of limited range of motion regarding knee extension were recruited. Knee flexion angles of the dominant limb were measured with a universal goniometer and the ROM © goniometric application for the smartphone. Three trained examiners compared the two assessment tools. Strong correlations were found between the measures of the universal goniometer and smartphone application (Pearson's correlation and interclass correlation coefficient > 0.93). The measurements with both devices demonstrated low dispersion and little variation. Measurements obtained using the smartphone goniometric application analyzed are as reliable as those of a universal goniometer. This application is therefore a useful tool for the evaluation of knee range of motion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Infrapatellar plica of the knee: Revisited with MR arthrographies undertaken in the knee flexion position mimicking operative arthroscopic posture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Han; Song, Ho-Taek; Kim, Sungjun [Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752 (Korea, Republic of); Kim, Sung-Jae [Department of Orthopedic Surgery and Arthroscopic Surgery Unit, Yonsei University College of Medicine (Korea, Republic of); Suh, Jin-Suck, E-mail: jss@yuhs.ac [Department of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, 250 Seongsanno, Seodaemun-gu, Seoul 120-752 (Korea, Republic of)

    2012-10-15

    Purpose: To describe the appearance of the infrapatellar plica (IPP) on magnetic resonance arthrography (MRA) taken in 70° knee flexion, corresponding to the arthroscopic posture. Materials and methods: Twenty-two patients (23 knee joints) who underwent MRA with 70° knee flexion were enrolled. All patients underwent MRA with 70° knee flexion to simulate operative arthroscopy. The images included fat-suppressed T1-weighted spin echo axial, sagittal, and coronal images. The visualization and morphology of the IPP were retrospectively assessed by two musculoskeletal radiologists. Results: The IPP was demonstrated in 78.3% (n = 18/23) and was best visualized on the sagittal section through the intercondylar notch. The IPP manifested as a linear hypointense structure with variable thicknesses. The intercondylar component was delineated clearly, arising from the anterior intercondylar notch in parallel with the ACL and curving gently downward to attach to the infrapatellar fat pad. On the other hand, the Hoffa's fat pad component was not depicted clearly. The morphology of the IPP was either a separate type (60.9%) or a split type (17.4%). Conclusion: The IPPs can be visualized with a high rate of detection and various morphologic appearances must be appreciated under the review of a flexed knee MRA.

  13. Partial knee replacement

    Science.gov (United States)

    ... good range of motion in your knee. The ligaments in your knee are stable. However, most people with knee arthritis have a surgery called a total knee arthroplasty (TKA). Knee replacement is most often done in people age 60 ...

  14. Kinetics features changes before and after intra-articular hyaluronic acid injections in patients with knee osteoarthritis.

    Science.gov (United States)

    Tang, Alice Chu-Wen; Tang, Simon Fuk-Tan; Hong, Wei-Hsien; Chen, Hsieh-Ching

    2015-02-01

    To examine the kinetic features in patients with knee osteoarthritis (OA) after intra-articular hyaluronic acid (IAHA) injections in different time periods. A single group repeated measures study. Gait laboratory in a tertiary hospital. Twenty-five subjects with bilateral symptomatic knee OA and 15 healthy control subjects. Gait analyses were performed in both control and OA groups before (baseline), and after the completion of IAHA injections (1 week, 3 months, and 6 months). Knee pain and functional indices were assessed using a visual analogue scale (VAS) and the Lequesne function Index (LI). Joint kinetic changes were analyzed in the frontal and sagittal planes with 6-camera motion analysis system and two AMTI force plates. VAS and LI scores were both improved in OA group after IAHA injections (pinjections (pinjections can provide significant pain relief and improvement in activity of daily living function for patients with knee OA. However, the reduction in pain and the increase in knee adduction moment may last up to 6 months. This may cause excessive loading on the knee joints, which may further accelerate the rate of knee degeneration. As a result, longer study time is needed to determine whether the observed kinetic findings in this study are associated with detrimental outcomes on the knee joints. © 2015 Elsevier B.V. All rights reserved.

  15. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    International Nuclear Information System (INIS)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R.; Keene, J.S.; Graf, B.K.

    1992-01-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.)

  16. Signs of patellar chondromalacia on sagittal T2-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    De Smet, A.A.; Monu, J.U.; Fisher, D.R. (Univ. of Wisconsin Hospital and Clinics, Dept. of Radiology, Madison, WI (United States)); Keene, J.S.; Graf, B.K. (Univ. of Wisconsin Hospital and Clinics, Div. of Orthopedic Surgery, Madison, WI (United States))

    1992-02-01

    We incidentally noted distinctive high signal defects or fissures in the patellar articular cartilage on sagittal T2-weighted magnetic resonance (MR) images in 4 patients. At subsequent arthroscopy all 4 patients were found to have patellar chondromalacia. To determine the reliabilty of these signs, we retrospectively evaluated, in a blinded manner, sagittal T2-weighted MR images of the knee in 75 patients who were undergoing arthroscopic assessment of their patellar articular cartilage. We indentified high signal defects of fissures in the patellar cartilage of 5 patients. Patellar chondromalacia was noted at arthroscopy in all 5 patients. Arthroscopy demonstrated patellar chondromalacia in an additional 21 patients with normal MR images. We conclude that high signal defects or fissures on sagittal T2-weighted images are usefull signs of patellar chondromalacia. This single imaging sequence will, however, detect only a small number of the cartilage lesions that may be present. (orig.).

  17. Use of inpatient continuous passive motion versus no CPM in computer-assisted total knee arthroplasty.

    Science.gov (United States)

    Alkire, Martha R; Swank, Michael L

    2010-01-01

    Continuous passive motion (CPM) has shown positive effects on tissue healing, edema, hemarthrosis, and joint function (L. Brosseau et al., 2004). CPM has also been shown to increase short-term early flexion and decrease length of stay (LOS) ( L. Brosseau et al., 2004; C. M. Chiarello, C. M. S. Gundersen, & T. O'Halloran, 2004). The benefits of CPM for the population of patients undergoing computer-assisted total knee arthroplasty (TKA) have not been examined. The primary objective of this study was to determine whether the use of CPM following computer-assisted TKA resulted in differences in range of motion, edema/drainage, functional ability, and pain. This was an experimental, prospective, randomized study of patients undergoing unilateral, computer-assisted TKA. The experimental group received CPM thrice daily and physical therapy (PT) twice daily during their hospitalization. The control group received PT twice daily and no CPM during the hospital stay. Both groups received PT after discharge. Measurement included Knee Society scores, Western Ontario McMaster Osteoarthritis Index values, range of motion, knee circumference, and HemoVac drainage. Data were collected at various intervals from preoperatively through 3 months. Although the control group was found to be higher functioning preoperatively, there was no statistically significant difference in flexion, edema or drainage, function, or pain between groups through the 3-month study period.

  18. Influence of Different Hip Joint Centre Locations on Hip and Knee Joint Kinetics and Kinematics During the Squat

    Directory of Open Access Journals (Sweden)

    Sinclair Jonathan

    2014-12-01

    Full Text Available Identification of the hip joint centre (HJC is important in the biomechanical examination of human movement. However, there is yet to be any published information regarding the influence of different HJC locations on hip and knee joint kinetics during functional tasks. This study aimed to examine the influence of four different HJC techniques on 3- D hip and knee joint kinetics/kinematics during the squat. Hip and knee joint kinetics/kinematics of the squat were obtained from fifteen male participants using an eight camera motion capture system. The 3-D kinetics/kinematics of the squat were quantified using four hip joint centre estimation techniques. Repeated measures ANOVAs were used to compare the discrete parameters as a function of each HJC location. The results show that significant differences in joint angles and moment parameters were evident at both the hip and knee joint in the coronal and transverse planes. These observations indicate that when calculating non-sagittal joint kinetics/kinematics during the squat, researchers should carefully consider their HJC method as it may significantly affect the interpretation of their data.

  19. EFFECTS OF FATIGUE ON FRONTAL PLANE KNEE MOTION, MUSCLE ACTIVITY, AND GROUND REACTION FORCES IN MEN AND WOMEN DURING LANDING

    Directory of Open Access Journals (Sweden)

    Michael P. Smith

    2009-09-01

    Full Text Available Women tear their Anterior Cruciate Ligament (ACL 2-8 times more frequently than men. Frontal plane knee motion can produce a pathological load in the ACL. During a state of fatigue the muscles surrounding the knee joint may lose the ability to protect the joint during sudden deceleration while landing. The purpose of this study was to investigate the effects of fatigue and gender on frontal plane knee motion, EMG amplitudes, and GRF magnitudes during drop- jump landing. Pretest-posttest comparison group design was used. Twenty-six volunteers (14 women; 12 Men; Mean ± standard deviation age = 24.5 ± 2.7 yrs; height = 1.73 ± 0.09 m; mass = 74.3 ± 11.8 kg participated in the study. Knee frontal plane ranges of motion and positions, ground reaction force peak magnitudes, and surface EMG RMS amplitudes from five lower extremity muscles (vastus medialis, vastus lateralis, medial hamstring, lateral hamstring, and lateral gastrocnemius were obtained during the landing phase of a drop-jump. MANOVA and ANOVA indicated that peak GRF significantly (p < 0.05; 2.50 ± 0.75 BW vs. 2.06 ± 0.93 BW decreased during fatigued landings. No other variables exhibited a fatigue main effect, although there was a significant (p < 0.05 fatigue by gender interaction for the frontal plane range of motion from initial contact to max knee flexion variable. Follow-up analyses failed to reveal significant gender differences at the different levels of fatigue for this variable. Additionally, no variables exhibited a significant gender main effect. Single subject analysis indicated that fatigue significantly altered frontal plane knee motion, peak GRF, and EMG in some subjects and the direction of differences varied by individual. Fatigue altered some aspects of landing performance in both men and women, but there were no gender differences. Additionally, both group and single subject analyses provided valuable but different information about factors representing

  20. An empirical study using range of motion and pain score as determinants for continuous passive motion: outcomes following total knee replacement surgery in an adult population.

    Science.gov (United States)

    Tabor, Danielle

    2013-01-01

    The continuous passive motion (CPM) machine is one means by which to rehabilitate the knee after total knee replacement surgery. This study sought to determine which total knee replacement patients, if any, benefit from the use of the CPM machine. For the study period, most patients received active physical therapy. Patients were placed in the CPM machine if, on postoperative day 1, they had a range of motion less than or equal to 45° and/or pain score of 8 or greater on a numeric rating scale of 0-10, 0 being no pain and 10 being the worst pain. Both groups of patients healed at similar rates. The incidence of adverse events, length of stay, and functional outcomes was comparable between groups. Given the demonstrated lack of relative benefit to the patient and the cost of the CPM, this study supported discontinuing the routine use of the CPM.

  1. Posterior Tibial Slope Angle Correlates With Peak Sagittal and Frontal Plane Knee Joint Loading During Robotic Simulations of Athletic Tasks

    Science.gov (United States)

    Bates, Nathaniel A.; Nesbitt, Rebecca J.; Shearn, Jason T.; Myer, Gregory D.; Hewett, Timothy E.

    2017-01-01

    Background Tibial slope angle is a nonmodifiable risk factor for anterior cruciate ligament (ACL) injury. However, the mechanical role of varying tibial slopes during athletic tasks has yet to be clinically quantified. Purpose To examine the influence of posterior tibial slope on knee joint loading during controlled, in vitro simulation of the knee joint articulations during athletic tasks. Study Design Descriptive laboratory study. Methods A 6 degree of freedom robotic manipulator positionally maneuvered cadaveric knee joints from 12 unique specimens with varying tibial slopes (range, −7.7° to 7.7°) through drop vertical jump and sidestep cutting tasks that were derived from 3-dimensional in vivo motion recordings. Internal knee joint torques and forces were recorded throughout simulation and were linearly correlated with tibial slope. Results The mean (6SD) posterior tibial slope angle was 2.2° ± 4.3° in the lateral compartment and 2.3° ± 3.3° in the medial compartment. For simulated drop vertical jumps, lateral compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee adduction (r = 0.60–0.65), flexion (r = 0.64–0.66), lateral (r = 0.57–0.69), and external rotation torques (r = 0.47–0.72) as well as inverse correlations with peak abduction (r = −0.42 to −0.61) and internal rotation torques (r = −0.39 to −0.79). Only frontal plane torques were correlated during sidestep cutting simulations. For simulated drop vertical jumps, medial compartment tibial slope angle expressed moderate, direct correlations with peak internally generated knee flexion torque (r = 0.64–0.69) and lateral knee force (r = 0.55–0.74) as well as inverse correlations with peak external torque (r = −0.34 to 20.67) and medial knee force (r = −0.58 to −0.59). These moderate correlations were also present during simulated sidestep cutting. Conclusion The investigation supported the theory that increased posterior

  2. Agreement Between Visual Assessment and 2-Dimensional Analysis During Jump Landing Among Healthy Female Athletes.

    Science.gov (United States)

    Rabin, Alon; Einstein, Ofira; Kozol, Zvi

    2018-04-01

      Altered movement patterns, including increased frontal-plane knee movement and decreased sagittal-plane hip and knee movement, have been associated with several knee disorders. Nevertheless, the ability of clinicians to visually detect such altered movement patterns during high-speed athletic tasks is relatively unknown.   To explore the association between visual assessment and 2-dimensional (2D) analysis of frontal-plane knee movement and sagittal-plane hip and knee movement during a jump-landing task among healthy female athletes.   Cross-sectional study.   Gymnasiums of participating volleyball teams.   A total of 39 healthy female volleyball players (age = 21.0 ± 5.2 years, height = 172.0 ± 8.6 cm, mass = 64.2 ± 7.2 kg) from Divisions I and II of the Israeli Volleyball Association.   Frontal-plane knee movement and sagittal-plane hip and knee movement during jump landing were visually rated as good, moderate, or poor based on previously established criteria. Frontal-plane knee excursion and sagittal-plane hip and knee excursions were measured using free motion-analysis software and compared among athletes with different visual ratings of the corresponding movements.   Participants with different visual ratings of frontal-plane knee movement displayed differences in 2D frontal-plane knee excursion ( P < .01), whereas participants with different visual ratings of sagittal-plane hip and knee movement displayed differences in 2D sagittal-plane hip and knee excursions ( P < .01).   Visual ratings of frontal-plane knee movement and sagittal-plane hip and knee movement were associated with differences in the corresponding 2D hip and knee excursions. Visual rating of these movements may serve as an initial screening tool for detecting altered movement patterns during jump landings.

  3. Combining valgus knee brace and lateral foot wedges reduces external forces and moments in osteoarthritis patients

    NARCIS (Netherlands)

    Jafarnezhadgero, Amir Ali; Oliveira, Anderson S.; Mousavi, Seyed Hamed; Madadi-Shad, Morteza

    Osteoarthritis progression can be related to the external knee adduction and flexion moments during walking. Lateral foot wedges and knee braces have been used as treatment for osteoarthritis, but little is known about their influence on knee joint moments generated in the sagittal and frontal

  4. Comparison of Range of Motion After Total Knee Prosthesis According to Different Type of Prosthesis

    Directory of Open Access Journals (Sweden)

    Firat Seyfettinoglu

    2016-07-01

    Full Text Available Aim: The aim of this study is to determine the effectiveness and range of motion of different type of knee prosthesis. Material and Method: This study includes 180 of 225 patients (139 F, 41 M, average age: 65, range of age: 51-82 between April 2005 and September 2007 with the diagnosis of gonarthrosis. All patients underwent to primary total knee arthroplasty. Primary osteoartrhritis is the reason of gonarthrosis. The patients with secondary osteoartrhritis were excluded from the study. All the patients were operated by the same surgical team and rehabilitated after surgery. Patella didnt change any patient. PCL was protected in some of the patients and cut some of patients. Totally seven type prosthesis in 16 subgroup were applied to the patients. All measurement were done by the same surgeon. Average follow up period was 31 months (24-49 months. Results: Patients without subgrouping were tested according to the range of motion before and after surgery to the type of the prosthesis trademark. Range of motion was decreased with the usage of Rotaglide and LCS® type of prosthesis. Range of motion didnt change with the usage of Maxim and Kinemax type. The range of motion increased in the other trademark of prosthesis. Flexion angle was increased statistically significant with nexgen® and scorpio® prosthesis (p

  5. Predicting the Functional Roles of Knee Joint Muscles from Internal Joint Moments

    DEFF Research Database (Denmark)

    Flaxman, Teresa E; Alkjær, Tine; Simonsen, Erik B

    2017-01-01

    INTRODUCTION: Knee muscles are commonly labeled as flexors or extensors and aptly stabilize the knee against sagittal plane loads. However, how these muscles stabilize the knee against adduction-abduction and rotational loads remains unclear. Our study sought 1) to classify muscle roles as they r...... on its role in maintaining knee joint stability in the frontal and transverse loading planes. This is useful for delineating the roles of biarticular knee joint muscles and could have implications in robotics, musculoskeletal modeling, sports sciences, and rehabilitation....

  6. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  7. [CPM--Continuous Passive Motion: treatment of injured or operated knee-joints using passive movement. A meta-analysis of current literature].

    Science.gov (United States)

    Kirschner, P

    2004-04-01

    There is still a controversial discussion in literature about the use of motor driven splints in knee surgery--as the principle of continuous passive motion, CPM. For this reason it seemed useful for an evaluation to look through the papers which were published since 1990. It was obvious, that negative results were published often before this year, but this papers are still quoted standard works. In medical data bases subito-doc.de, medscape.com, medica.de and zbmed.de 230 papers were found by search CPM, continuous passive motion and arthromot. Coincidentally there was a search for authors who were already quoted in other papers. 36 papers concerning CPM after knee surgery were utilized. The role of CPM regarding the range of motion, swelling, duration of hospital stay, use of analgesics, costs, postoperative manipulations, wound healing and thrombo embolic complications was evaluated. Although the results of this partial retrospective, partial prospective, sometimes randomized or double blinded studies are in contradiction, there can only be found a trend to better results. New clinical studies for evidence based guidelines in the handling of continuous passive motion after knee surgery are necessary.

  8. Walking sagittal balance correction by pedicle subtraction osteotomy in adults with fixed sagittal imbalance.

    Science.gov (United States)

    Yagi, Mitsuru; Kaneko, Shinjiro; Yato, Yoshiyuki; Asazuma, Takashi; Machida, Masafumi

    2016-08-01

    Pedicle subtraction osteotomy (PSO) is widely used to treat severe fixed sagittal imbalance. However, the effect of PSO on balance has not been fully documented. The aim of this study was to assess dynamic walking balance after PSO to treat fixed sagittal imbalance. Gait and balance were assessed in 15 consecutive adult female patients who had been treated by PSO for a fixed sagittal imbalance and compare patients' preop and postop dynamic walking balance with that of 15 age- and gender-matched healthy volunteers (HV). Each patient's chart, X-rays, pre and postop SRS22 outcome scores, and ODI were reviewed. Means were compared by Mann-Whitney U test and Chi-square test. The mean age was 66.3 years (51-74 years). The mean follow-up was 2.7 years (2-3.5 years). The C7PL and GL, measured on the force platform, were both improved from 24.2 ± 7.3 cm and 27.6 ± 9.4 to 5.4 ± 2.6 cm and 7.2 ± 3.4 cm, respectively. The baseline hip ROM was significantly smaller in patients compared to HV, whereas no significant difference was observed in the knee or ankle ROM. The pelvic tilt (preop -0.4° ± 1.4°, postop 8.9° ± 1.0°), and maximum hip-extension angle (preop -1.2° ± 14.2°, postop -11.2° ± 7.2°) were also improved after surgery. Cadence (116 s/min), stance-swing ratio (stance 63.2 % vs. swing 36.8 %), and stride (98.0 cm) were all increased after surgery. On the other hand, gait velocity was significantly slower in the PSO group at both pre and postop than in HV (PSO 53.3 m/min at preop and 58.8 m/min at postop vs. HV 71.1 m/min, p = 0.04). Despite a mild residual spinal-pelvic malalignment, PSO restored sagittal alignment and balance satisfactorily and has improved the gait pattern.

  9. The sagittal stem alignment and the stem version clearly influence the impingement-free range of motion in total hip arthroplasty: a computer model-based analysis.

    Science.gov (United States)

    Müller, Michael; Duda, Georg; Perka, Carsten; Tohtz, Stephan

    2016-03-01

    The component alignment in total hip arthroplasty influences the impingement-free range of motion (ROM). While substantiated data is available for the cup positioning, little is known about the stem alignment. Especially stem rotation and the sagittal alignment influence the position of the cone in relation to the edge of the socket and thus the impingement-free functioning. Hence, the question arises as to what influence do these parameters have on the impingement-free ROM? With the help of a computer model the influence of the sagittal stem alignment and rotation on the impingement-free ROM were investigated. The computer model was based on the CT dataset of a patient with a non-cemented THA. In the model the stem version was set at 10°/0°/-10° and the sagittal alignment at 5°/0°/-5°, which resulted in nine alternative stem positions. For each position, the maximum impingement-free ROM was investigated. Both stem version and sagittal stem alignment have a relevant influence on the impingement-free ROM. In particular, flexion and extension as well as internal and external rotation capability present evident differences. In the position intervals of 10° sagittal stem alignment and 20° stem version a difference was found of about 80° in the flexion and 50° in the extension capability. Likewise, differences were evidenced of up to 72° in the internal and up to 36° in the external rotation. The sagittal stem alignment and the stem torsion have a relevant influence on the impingement-free ROM. To clarify the causes of an impingement or accompanying problems, both parameters should be examined and, if possible, a combined assessment of these factors should be made.

  10. Effects of prophylactic knee bracing on knee joint kinetics and kinematics during netball specific movements.

    Science.gov (United States)

    Sinclair, Jonathan K; Vincent, Hayley; Richards, Jim D

    2017-01-01

    To investigate the effects of a prophylactic knee brace on knee joint kinetics and kinematics during netball specific movements. Repeated measures. Laboratory. Twenty university first team level female netball players. Participants performed three movements, run, cut and vertical jump under two conditions (brace and no-brace). 3-D knee joint kinetics and kinematics were measured using an eight-camera motion analysis system. Knee joint kinetics and kinematics were examined using 2 × 3 repeated measures ANOVA whilst the subjective ratings of comfort and stability were investigated using chi-squared tests. The results showed no differences (p > 0.05) in knee joint kinetics. However the internal/external rotation range of motion was significantly (p < 0.05) reduced when wearing the brace in all movements. The subjective ratings of stability revealed that netballers felt that the knee brace improved knee stability in all movements. Further study is required to determine whether reductions in transverse plane knee range of motion serve to attenuate the risk from injury in netballers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Clinically assessed mediolateral knee motion: impact on gait

    DEFF Research Database (Denmark)

    Thorlund, Jonas Bloch; Creaby, Mark W; Simic, Milena

    2011-01-01

    Mediolateral knee movement can be assessed visually with clinical tests. A knee-medial-to-foot position is associated with an increased risk of knee injuries and pathologies. However, the implications of such findings on daily tasks are not well understood. The aim of this study was to investigat...... if a knee-medial-to-foot position assessed during a clinical test was associated with altered hip and knee joint kinematics and knee joint kinetics during gait compared with those with a knee-over-foot position....

  12. Knee joint changes in patients with neglected developmental hip dysplasia: a prospective case-control study.

    Science.gov (United States)

    Li, Qiwei; Kadhim, Muayad; Zhang, Lijun; Cheng, Xiangjun; Zhao, Qun; Li, Lianyong

    2014-12-01

    Few reports are available describing knee changes in neglected developmental dysplasia of the hip (DDH). The purpose of this study was to assess the radiographic morphology of knee joints in adults with neglected DDH. Thirty-seven patients (35 females and two males) with neglected DDH were prospectively recruited with an average age of 32.6 years. Twenty-three patients had unilateral and 14 patients had bilateral neglected DDH. Thirty-seven healthy individuals were recruited to form a matched control group. Three groups of knee joints were examined: affected knees (on the same side of the neglected DDH), unaffected knees (contralateral to the neglected DDH in patients with unilateral involvement), and control knees. A series of radiographic parameters of the knee joint were measured in the coronal and sagittal plane, and they were compared between patients and normal controls. In the coronal plane, the affected knees had increased valgus angulation related to increased height of the medial femoral condyle, decreased height of the lateral femoral condyle and decreased lateral distal femoral angle compared to control knees. In the sagittal plane, both distal femoral and proximal tibial joints of the affected knees developed a decrease in posterior angles. Additionally, the unaffected knees also developed radiographic changes compared to control knees. Patients with neglected DDH may develop changes in both knee joints. These changes should be considered during surgery to the hip, femur and knee to prevent potential complications. Level 2. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Increased conformity offers diminishing returns for reducing total knee replacement wear.

    Science.gov (United States)

    Fregly, Benjamin J; Marquez-Barrientos, Carlos; Banks, Scott A; DesJardins, John D

    2010-02-01

    Wear remains a significant problem limiting the lifespan of total knee replacements (TKRs). Though increased conformity between TKR components has the potential to decrease wear, the optimal amount and planes of conformity have not been investigated. Furthermore, differing conformities in the medial and lateral compartments may provide designers the opportunity to address both wear and kinematic design goals simultaneously. This study used a computational model of a Stanmore knee simulator machine and a previously validated wear model to investigate this issue for simulated gait. TKR geometries with different amounts and planes of conformity on the medial and lateral sides were created and tested in two phases. The first phase utilized a wide range of sagittal and coronal conformity combinations to blanket a physically realistic design space. The second phase performed a focused investigation of the conformity conditions from the first phase to which predicted wear volume was sensitive. For the first phase, sagittal but not coronal conformity was found to have a significant effect on predicted wear volume. For the second phase, increased sagittal conformity was found to decrease predicted wear volume in a nonlinear fashion, with reductions gradually diminishing as conformity increased. These results suggest that TKR geometric design efforts aimed at minimizing wear should focus on sagittal rather than coronal conformity and that at least moderate sagittal conformity is desirable in both compartments.

  14. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    International Nuclear Information System (INIS)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B.; Brooks, Jeffrey J.

    2018-01-01

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  15. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B. [Yale New Haven Health Bridgeport Hospital, Bridgeport, CT (United States); Brooks, Jeffrey J. [Orthopedic Surgery and Sports Medicine Center, New Canaan, CT (United States)

    2018-04-15

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  16. FUNCTIONAL IMPROVEMENT UP TO SIX MONTHS AFTER TOTAL KNEE ARTHROPLASTY: MEASURED BY KNEE RANGE OF MOTION AND SELF-REPORTED QUESTIONNAIRE

    Directory of Open Access Journals (Sweden)

    Mirjana Kocić

    2015-12-01

    Full Text Available The primary aim of this study was to assess knee range of motion (ROM as well as patients’ reported pain, stiffness and function up to six months after total knee arthroplasty (TKA. The secondary aim was to analyze the extent to which knee ROM correlates with patient-rated outcome. A prospective study included 60 patients with primary TKA for osteorthritis, admitted at Physical Medicine and Rehabilitation Clinic from April 2009 to October 2014. The patients were evaluated at 4 time points: at admission and at discharge, as well as at follow-up at 3 and at 6 months after surgery. The outcome parameters included: active knee ROM, as well as pain, stiffness and function according to self reported Western Ontario and McMaster Universities Osteoarthritis (WOMAC questionnaire. Statistically highly significant improvement in flexion and extension was observed from admission to all other assessment time points (p<0.001. Also, statistically significant improvement of all three WOMAC subscales (pain, stiffness and function was found between all assessments points (p<0.001. According to values of Spearman correlation coefficient, there was significant negative correlation of flexion with all WOMAC subscales at all assessment points, whereas correlation of extension with any assessed outcome parameter was without significance. It can be concluded that in TKA patients all outcome measures improved significantly from admission to 6 months follow-up. Knee flexion ROM negatively and moderately to strongly correlated with pain, stiffness and function, whereas correlation of extension with any assessed outcome measure was without significance.

  17. Dynamic knee alignment and collateral knee laxity and its variations in normal humans

    Directory of Open Access Journals (Sweden)

    Kamal eDeep

    2015-11-01

    Full Text Available Alignment of normal, arthritic and replaced human knees is a much debated subject as is the collateral ligamentous laxity. Traditional quantitative values have been challenged. Methods used to measure these are also not without flaws. Authors review the recent literature and a novel method of measurement of these values has been included. This method includes use of computer navigation technique in clinic setting for assessment of the normal or affected knee before the surgery. Computer navigation has been known for achievement of alignment accuracy during knee surgery. Now its use in clinic setting has added to the inventory of measurement methods. Authors dispel the common myth of straight mechanical axis in normal knees and also look at quantification of amount of collateral knee laxity. Based on the scientific studies it has been shown that the mean alignment is in varus in normal knees. It changes from lying non weight bearing position to standing weight bearing position in both coronal and the sagittal planes. It also varies with gender and race. The collateral laxity is also different for males and females. Further studies are needed to define the ideal alignment and collateral laxity which the surgeon should aim for individual knees.

  18. Effectiveness of prolonged use of continuous passive motion (CPM) as an adjunct to physiotherapy following total knee arthroplasty: Design of a randomised controlled trial [ISRCTN85759656

    Science.gov (United States)

    Lenssen, Anton F; Crijns, Yvonne HF; Waltjé, Eddie MH; Roox, George M; van Steyn, Mike JA; Geesink, Ruud JT; van den Brandt, Piet A; de Bie, Rob A

    2006-01-01

    Background Adequate and intensive rehabilitation is an important requirement for successful Total Knee Arthroplasty. The primary focus of early rehabilitation is ambulation of patients and regaining range of motion in the knee. Although research suggests that Continuous Passive Motion should be implemented in the first rehabilitation phase following surgery, there is substantial debate about the duration of each session and the total period of CPM application and. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. Methods In a randomised controlled trial we intend to investigate the efficacy of prolonged use of a continuous passive motion (CPM) device in the home situation as an adjunct to standardised physical therapy. The experimental treatment is compared to standardised physical therapy, in patients with osteoarthritis of the knee undergoing Total Knee Arthroplasty (TKA). Efficacy will be assessed in terms of faster improvements in range of motion and functional recovery. Seventy patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment (less than 80° of knee flexion at the time of discharge) will be randomised over two treatment groups, a usual care group and an experimental group The experimental group will receive CPM + physiotherapy for 17 consecutive days after surgery, whereas the usual care group will receive the same treatment during the in-hospital phase (i.e. about four days), followed by physical therapy alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after discharge, both groups will receive standardised PT. The primary focus of rehabilitation will be functional recovery (e.g. ambulation) and regaining range of motion (ROM) in the knee. Discussion Because

  19. Effectiveness of prolonged use of continuous passive motion (CPM) as an adjunct to physiotherapy following total knee arthroplasty: design of a randomised controlled trial [ISRCTN85759656].

    Science.gov (United States)

    Lenssen, Anton F; Crijns, Yvonne H F; Waltjé, Eddie M H; Roox, George M; van Steyn, Mike J A; Geesink, Ruud J T; van den Brandt, Piet A; de Bie, Rob A

    2006-02-23

    Adequate and intensive rehabilitation is an important requirement for successful Total Knee Arthroplasty. The primary focus of early rehabilitation is ambulation of patients and regaining range of motion in the knee. Although research suggests that Continuous Passive Motion should be implemented in the first rehabilitation phase following surgery, there is substantial debate about the duration of each session and the total period of CPM application and. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. In a randomised controlled trial we intend to investigate the efficacy of prolonged use of a continuous passive motion (CPM) device in the home situation as an adjunct to standardised physical therapy. The experimental treatment is compared to standardised physical therapy, in patients with osteoarthritis of the knee undergoing Total Knee Arthroplasty (TKA). Efficacy will be assessed in terms of faster improvements in range of motion and functional recovery. Seventy patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment (less than 80 degrees of knee flexion at the time of discharge) will be randomised over two treatment groups, a usual care group and an experimental group. The experimental group will receive CPM + physiotherapy for 17 consecutive days after surgery, whereas the usual care group will receive the same treatment during the in-hospital phase (i.e. about four days), followed by physical therapy alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after discharge, both groups will receive standardised PT. The primary focus of rehabilitation will be functional recovery (e.g. ambulation) and regaining range of motion (ROM) in the knee. Because restricted knee ROM affects

  20. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    OpenAIRE

    Hirschmann, Michael T; Konala, Praveen; Iranpour, Farhad; Kerner, Anna; Rasch, Helmut; Friederich, Niklaus F

    2011-01-01

    Abstract Background The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA). Methods Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10) and its anatomical distribution was mapped using a validated localization sch...

  1. Male and female runners demonstrate different sagittal plane mechanics as a function of static hamstring flexibility

    Directory of Open Access Journals (Sweden)

    D. S. Blaise Williams III

    2015-10-01

    Full Text Available ABSTRACTBackground:Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females.Objective: To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners.Method: Forty subjects (30.0±6.4 years participated and were placed in one of 4 groups: flexible males (n=10, inflexible males (n=10, flexible females (n=10, and inflexible females (n=10. All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility ANOVA (α=0.05.Results: Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05 and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01. For hip flexion at initial contact, a significant interaction existed (p<0.05. Flexible females (36.7±7.4º exhibited more hip flexion than inflexible females (27.9±4.6º, p<0.01 and flexible males (30.1±9.5º, p<0.05. No differences existed for knee angle at initial contact, peak knee angle, peak hip angle, or peak hip moment.Conclusion: Hamstring flexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners.

  2. Interactive videodisk atlas of knee anatomy

    International Nuclear Information System (INIS)

    McEnery, K.W.; Woods, J.W.; Glenn, W.F.; Rauschning, W.

    1987-01-01

    An interactive, computer-assisted atlas of knee anatomy has been developed. MR and CT images from normal volunteers and cryomicrotomed anatomic images were recorded on a laser viodeodisk. Computer software allows movement through the knee and correlation of radiographic images in the coronal, axial, and sagittal planes. Computer graphics are superimposed on the videodisk images. A high-resolution color graphics, touch-screen monitor is included in the computer system. Learning modules allow for rapid identification of specific structure by touching their location on the screen. Computer-created testing modules are available that provide for self-assessment

  3. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. Part I. Numerical model-based optimization.

    Science.gov (United States)

    Choi, Jang-Hwan; Fahrig, Rebecca; Keil, Andreas; Besier, Thor F; Pal, Saikat; McWalter, Emily J; Beaupré, Gary S; Maier, Andreas

    2013-09-01

    Human subjects in standing positions are apt to show much more involuntary motion than in supine positions. The authors aimed to simulate a complicated realistic lower body movement using the four-dimensional (4D) digital extended cardiac-torso (XCAT) phantom. The authors also investigated fiducial marker-based motion compensation methods in two-dimensional (2D) and three-dimensional (3D) space. The level of involuntary movement-induced artifacts and image quality improvement were investigated after applying each method. An optical tracking system with eight cameras and seven retroreflective markers enabled us to track involuntary motion of the lower body of nine healthy subjects holding a squat position at 60° of flexion. The XCAT-based knee model was developed using the 4D XCAT phantom and the optical tracking data acquired at 120 Hz. The authors divided the lower body in the XCAT into six parts and applied unique affine transforms to each so that the motion (6 degrees of freedom) could be synchronized with the optical markers' location at each time frame. The control points of the XCAT were tessellated into triangles and 248 projection images were created based on intersections of each ray and monochromatic absorption. The tracking data sets with the largest motion (Subject 2) and the smallest motion (Subject 5) among the nine data sets were used to animate the XCAT knee model. The authors defined eight skin control points well distributed around the knees as pseudo-fiducial markers which functioned as a reference in motion correction. Motion compensation was done in the following ways: (1) simple projection shifting in 2D, (2) deformable projection warping in 2D, and (3) rigid body warping in 3D. Graphics hardware accelerated filtered backprojection was implemented and combined with the three correction methods in order to speed up the simulation process. Correction fidelity was evaluated as a function of number of markers used (4-12) and marker distribution

  4. Effectiveness of prolonged use of continuous passive motion (CPM as an adjunct to physiotherapy following total knee arthroplasty: Design of a randomised controlled trial [ISRCTN85759656

    Directory of Open Access Journals (Sweden)

    Geesink Ruud JT

    2006-02-01

    Full Text Available Abstract Background Adequate and intensive rehabilitation is an important requirement for successful Total Knee Arthroplasty. The primary focus of early rehabilitation is ambulation of patients and regaining range of motion in the knee. Although research suggests that Continuous Passive Motion should be implemented in the first rehabilitation phase following surgery, there is substantial debate about the duration of each session and the total period of CPM application and. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. Methods In a randomised controlled trial we intend to investigate the efficacy of prolonged use of a continuous passive motion (CPM device in the home situation as an adjunct to standardised physical therapy. The experimental treatment is compared to standardised physical therapy, in patients with osteoarthritis of the knee undergoing Total Knee Arthroplasty (TKA. Efficacy will be assessed in terms of faster improvements in range of motion and functional recovery. Seventy patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment (less than 80° of knee flexion at the time of discharge will be randomised over two treatment groups, a usual care group and an experimental group The experimental group will receive CPM + physiotherapy for 17 consecutive days after surgery, whereas the usual care group will receive the same treatment during the in-hospital phase (i.e. about four days, followed by physical therapy alone (usual care in the first two weeks after hospital discharge. From 18 days to three months after discharge, both groups will receive standardised PT. The primary focus of rehabilitation will be functional recovery (e.g. ambulation and regaining range of motion (ROM in the knee

  5. MR imaging of the flexed knee: comparison to the extended knee in delineation of meniscal lesions

    International Nuclear Information System (INIS)

    Niitsu, M.; Itai, Y.; Endo, H.; Ikeda, K.

    2000-01-01

    The aim of this study was to obtain MR images in the flexed-knee position and to compare the diagnostic value to the extended position in delineation of the menisci. With a mobile knee brace and a flexible surface coil, the knee joint was either fully extended or bent to a semi-flexed position (average 45 of flexion) within a 1.5-T superconducting magnet. Sets of sagittal MR images were obtained for both the extended- and flexed-knee positions. Using the arthroscopic results as gold standards, 97 menisci were evaluated. Two observers interpreted each MR image of the extended and flexed positions independently without knowledge of the arthroscopic results. Flexed-knee MR images revealed 22 of the 27 arthroscopically proven torn menisci and 69 of the 70 intact menisci, for a sensitivity of 81.5 %, a specificity of 98.6 %, and an accuracy of 93.8 %. Extended-knee MR images indicated a sensitivity of 81.5 %, a specificity of 92.9 %, and an accuracy of 89.7 %. No statistically significant difference was found between the two positions. To enhance MR visualization of all the knee components, we recommend examining the knee in a flexed position within the magnet. (orig.)

  6. MR imaging of the flexed knee: comparison to the extended knee in delineation of meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, M.; Itai, Y. [Dept. of Radiology, Institute of Clinical Medicine, University of Tsukuba Tennodai, Tsukuba, Ibaraki (Japan); Endo, H. [Tsukuba Medical Center Hospital, Ibaraki (Japan); Ikeda, K. [Dept. of Orthopedic Surgery, University of Tsukuba Tennodai, Tsukuba (Japan)

    2000-11-01

    The aim of this study was to obtain MR images in the flexed-knee position and to compare the diagnostic value to the extended position in delineation of the menisci. With a mobile knee brace and a flexible surface coil, the knee joint was either fully extended or bent to a semi-flexed position (average 45 of flexion) within a 1.5-T superconducting magnet. Sets of sagittal MR images were obtained for both the extended- and flexed-knee positions. Using the arthroscopic results as gold standards, 97 menisci were evaluated. Two observers interpreted each MR image of the extended and flexed positions independently without knowledge of the arthroscopic results. Flexed-knee MR images revealed 22 of the 27 arthroscopically proven torn menisci and 69 of the 70 intact menisci, for a sensitivity of 81.5 %, a specificity of 98.6 %, and an accuracy of 93.8 %. Extended-knee MR images indicated a sensitivity of 81.5 %, a specificity of 92.9 %, and an accuracy of 89.7 %. No statistically significant difference was found between the two positions. To enhance MR visualization of all the knee components, we recommend examining the knee in a flexed position within the magnet. (orig.)

  7. The Effect of Music Listening on Pain, Heart Rate Variability, and Range of Motion in Older Adults After Total Knee Replacement.

    Science.gov (United States)

    Hsu, Chih-Chung; Chen, Su-Ru; Lee, Pi-Hsia; Lin, Pi-Chu

    2017-12-01

    The purpose of this study was to investigate the effects that listening and not listening to music had on pain relief, heart rate variability (HRV), and knee range of motion in total knee replacement (TKR) patients who underwent continuous passive motion (CPM) rehabilitation. We adopted a single-group quasi-experimental design. A sample of 49 TKR patients listened to music for 25 min during one session of CPM and no music during another session of CPM the same day for a total of 2 days. Results indicated that during CPM, patients exhibited a significant decrease in the pain level ( p listening to music compared with no music. This study demonstrated that listening to music can effectively decrease pain during CPM rehabilitation and improve the joint range of motion in patients who underwent TKR surgery.

  8. Relationship between flexion contractures of the joints of the lower extremities and the sagittal profile of the spine in patients with cerebral palsy: a preliminary report

    Directory of Open Access Journals (Sweden)

    Valery V. Umnov

    2016-11-01

    Full Text Available Background. The considerable incidence of kyphosis in patients with cerebral palsy (CP causes back pain and aggravates movement disorders. However, few studies have investigated the pathogenesis of this condition. Aim. To identify the relationship between patient motor abilities, the severity of flexion contractures of the knee and hip joints and spinal sagittal profile changes, and the impact on the latter by surgical correction of flexion contracture of the knee joint. Material and methods. The study cohort included 17 pediatric CP patients (11 boys and 6 girls with a mean age of 13.1 ± 1.3 (range, 10–16 years and level 2–4 spastic diplegia according to the Gross Motor Function Classification System. The relationship between radiological indicators of the spine sagittal profile and motor abilities of children, as well as the severity of flexion contractures at the hip and knee, and the degree of insufficiency of the active extension of the knee were investigated. Of these 17 patients, 12 underwent surgery to correct flexion contracture of the knee, which involved lengthening of leg flexors, to analyze the impact of contracture on the sagittal profile of the spine. The following radiological indicators were assessed: angle of thoracic kyphosis (CC, lordosis angle (UL of the lumbar spine, and sacral inclination angle (SS. The study included patients with a CC of at least 30°. Results. Results of an X-ray study showed that the severity of kyphosis was 50.7° ± 2.1°, lordosis was 30.3° ± 4.3°, and SS was 30.5° ± 3.3°. There was a significant association between kyphosis and flexion contracture of the knee joint, as well as between lordosis and insufficient active extension of the knee joint. After elimination of the flexion contracture of the knee, the degree of severity of the CC (thoracic kyphosis was unchanged, while UL (lordosis angle and SS (sacral inclination angle increased by approximately 10°. Conclusion. The severity of

  9. Reliability and measurement error of sagittal spinal motion parameters in 220 patients with chronic low back pain using a three-dimensional measurement device.

    Science.gov (United States)

    Mieritz, Rune M; Bronfort, Gert; Jakobsen, Markus D; Aagaard, Per; Hartvigsen, Jan

    2014-09-01

    A basic premise for any instrument measuring spinal motion is that reliable outcomes can be obtained on a relevant sample under standardized conditions. The purpose of this study was to assess the overall reliability and measurement error of regional spinal sagittal plane motion in patients with chronic low back pain (LBP), and then to evaluate the influence of body mass index, examiner, gender, stability of pain, and pain distribution on reliability and measurement error. This study comprises a test-retest design separated by 7 to 14 days. The patient cohort consisted of 220 individuals with chronic LBP. Kinematics of the lumbar spine were sampled during standardized spinal extension-flexion testing using a 6-df instrumented spatial linkage system. Test-retest reliability and measurement error were evaluated using interclass correlation coefficients (ICC(1,1)) and Bland-Altman limits of agreement (LOAs). The overall test-retest reliability (ICC(1,1)) for various motion parameters ranged from 0.51 to 0.70, and relatively wide LOAs were observed for all parameters. Reliability measures in patient subgroups (ICC(1,1)) ranged between 0.34 and 0.77. In general, greater (ICC(1,1)) coefficients and smaller LOAs were found in subgroups with patients examined by the same examiner, patients with a stable pain level, patients with a body mass index less than below 30 kg/m(2), patients who were men, and patients in the Quebec Task Force classifications Group 1. This study shows that sagittal plane kinematic data from patients with chronic LBP may be sufficiently reliable in measurements of groups of patients. However, because of the large LOAs, this test procedure appears unusable at the individual patient level. Furthermore, reliability and measurement error varies substantially among subgroups of patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. MRI of normal anterior cruciate ligament (ACL) and reconstructed ACL: comparison of when the knee is extended with when the knee is flexed

    International Nuclear Information System (INIS)

    Nakanishi, K.; Horibe, S.; Shiozaki, Y.; Ishida, T.; Narumi, Y.; Ikezoe, J.; Nakamura, H.

    1997-01-01

    The purpose of this study was to evaluate, using MRI, the morphology of normal anterior cruciate ligament (ACL) and ACL grafts when the knee was extended compared with when the knee was flexed. Eighteen normal controls and 22 ACL graft patients were studied. Spin-echo (SE) T1-weighted images (TR 330 ms/TE 15 ms, NEX 1) were obtained with a slice thickness of 3 mm. Oblique sagittal images parallel to the ACL were obtained at various flexed angles of the knee joint. In 12 of the 18 normal controls the ACL appeared convex toward the posterior side when the knee was extended and gradually became straight when the knee was flexed. In 15 of the 22 ACL graft patients the grafts appeared straight when the knee was extended and became convex toward the anterior side when the knee was flexed. It is concluded that the morphological changes seen on MR images of ACL grafts from when the knee is extended to when the knee is flexed are different from those in the normal ACL. (orig.). With 7 figs., 1 tab

  11. The Cruciate Ligaments in Total Knee Arthroplasty.

    Science.gov (United States)

    Parcells, Bertrand W; Tria, Alfred J

    2016-01-01

    The early knee replacements were hinge designs that ignored the ligaments of the knee and resurfaced the joint, allowing freedom of motion in a single plane. Advances in implant fixation paved the way for modern designs, including the posterior-stabilized (PS) total knee arthroplasty (TKA) that sacrifices both cruciate ligaments while substituting for the posterior cruciate ligament (PCL), and the cruciate-retaining (CR) TKA designs that sacrifice the anterior cruciate ligament but retain the PCL. The early bicruciate retaining (BCR) TKA designs suffered from loosening and early failures. Townley and Cartier designed BCR knees that had better clinical results but the surgical techniques were challenging.Kinematic studies suggest that normal motion relies on preservation of both cruciate ligaments. Unicompartmental knee arthroplasty retains all knee ligaments and closely matches normal motion, while PS and CR TKA deviate further from normal. The 15% to 20% dissatisfaction rate with current TKA has renewed interest in the BCR design. Replication of normal knee kinematics and proprioception may address some of the dissatisfaction.

  12. The angle of inclination of the native ACL in the coronal and sagittal planes.

    Science.gov (United States)

    Reid, Jonathan C; Yonke, Bret; Tompkins, Marc

    2017-04-01

    The purpose of this cross-sectional study was to evaluate the angle of inclination of the native anterior cruciate ligament (ACL) in both the sagittal and coronal planes and to evaluate these findings based on sex, height, BMI, and skeletal maturity. Inclusion criteria for the study included patients undergoing routine magnetic resonance imaging (MRI) of the knee at a single outpatient orthopedic center who had an intact ACL on MRI. Measurements of the angle of inclination were made on MRIs in both the sagittal and coronal planes. Patients were compared based on sex, height, BMI, and skeletal maturity. One-hundred and eighty-eight patients were included (36 skeletally immature/152 skeletally mature; 98 male/90 female). The overall angle of inclination was 74.3° ± 4.8° in the coronal plane and 46.9° ± 4.9° in the sagittal plane. Skeletally immature patients (coronal: 71.8° ± 6.1°; sagittal: 44.7° ± 5.5°) were significantly different in both coronal and sagittal planes (P = 0.04 and 0.01, respectively) from skeletally mature patients (coronal: 75.3° ± 4.7°; sagittal: 47.4° ± 4.7°). There were no differences based on sex, height, or BMI. There are differences between the angle of inclination findings in this study and other studies, which could be due to MRI and measurement techniques. Clinically, skeletal maturity may be important to account for when using the ACL angle of inclination to evaluate anatomic ACL reconstruction. Prognostic retrospective study, Level of evidence III.

  13. Male and female runners demonstrate different sagittal plane mechanics as a function of static hamstring flexibility.

    Science.gov (United States)

    Williams, D S Blaise; Welch, Lee M

    2015-01-01

    Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females. To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners. Forty subjects (30.0±6.4 years) participated and were placed in one of 4 groups: flexible males (n=10), inflexible males (n=10), flexible females (n=10), and inflexible females (n=10). All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility) ANOVA (α=0.05). Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05) and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01). For hip flexion at initial contact, a significant interaction existed (pHamstring flexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners.

  14. A study to find out the immediate effect of macquarie injury management group (mimg protocol on pain and range of motion in primary osteoarthritis knee patients- an interventional study

    Directory of Open Access Journals (Sweden)

    Dr. Shukla Yashasvi S.

    2016-10-01

    Full Text Available Osteoarthritis is a disorder of the diarthrodial joint, a slow degenerative disease clinically characterized by pain, loss of range of motion. On a radiograph seen as reduced joint space, formation of osteophytes, sclerosis of bone and deformity. Manual therapy has been proved to be an effective treatment method in knee osteoarthritis (OA, but there is a need to investigate effectiveness of MIMG manual therapy technique. There is limited evidence on effect of MIMG protocol in knee OA. To find the effectiveness of MIMG protocol on pain and range of motion in knee osteoarthritis. 30 subjects with the diagnosis of knee OA stage II and III on Kellegren Lawrence classification were recruited from Shree K.K.Sheth physiotherapy Centre, Rajkot, Gujarat. An interventional study was conducted on 30 subjects. The outcome measures were Pain and Range of Motion (ROM. The intra group comparison was statistically significant with p= <0.001. MIMG protocol is effective in treating OA knee. Hence it can be suggested as one of the treatment regime.

  15. Comparison of Joint Loading in Badminton Lunging between Professional and Amateur Badminton Players

    Science.gov (United States)

    Fu, Lin

    2017-01-01

    The knee and ankle are the two most injured joints associated with the sport of badminton. This study evaluates biomechanical factors between professional and amateur badminton players using an injury mechanism model. The aim of this study was to investigate the kinematic motion and kinetic loading differences of the right knee and ankle while performing a maximal right lunge. Amateur players exhibited greater ankle range of motion (p badminton players presented a greater knee joint moment in the sagittal (p badminton players should account for these findings to reduce potential injury to the ankle and knee. PMID:28694684

  16. MR imaging of the knee using fat suppression technique: a preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Jin Suck; Kim, Mi Hye; Cho, Jae Hyun; Park, Chang Yun; Lee, Yeon Hee [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kim, Yong Soo [Inje University College of Medicine, Kimhae (Korea, Republic of)

    1994-03-15

    The purpose of this study is to evaluate the usefulness of fat suppression technique for MR imaging of the knee. Twenty-eight knees of 26 patients were imaged at a 1.5 T MR system. Sagittal and coronal T2-weighted spin echo imaged (SET2) and sagittal fat suppression SET2(FSSE) were obtained in all cases. We used a chemical shift imaging method for fat suppression. We compared FSSE with SET2 in terms of the conspicuity of lesions of menisci, cruciate ligaments, cartilage, bone and soft tissue of the knee. Meniscal lesions were detected on FSSE and SET2 as well. FSSE depicted the lesion more conspicuously in 6 cases. For the depiction of ACL tear, SET2 was superior to FSSE in 5 cases. FSSE was better for the visualization of the normal structure of cartilage and it also depicted the cartilaginous lesions more conspicuously in 3 cases. Though bone bruise could be detected on both techniques, FSSE was better. FSSE could provide the improved delineation of menisci, cartilage, bone bruise and other soft tissues except the injuries of anterior cruciate ligament. Although FSSE is a reliable method, it can not replace SET2. It may be used as a complemental method in the imaging of the knee.

  17. Knee and hip sagittal and transverse plane changes after two fatigue protocols

    Science.gov (United States)

    Lucci, Shawn; Cortes, Nelson; Van Lunen, Bonnie; Ringleb, Stacie; Onate, James

    2013-01-01

    Fatigue has been shown to alter the biomechanics of lower extremity during landing tasks. To date, no study has examined the effects of two types of fatigue on kinetics and kinematics. Objectives This study was conducted to assess biomechanical differences between two fatigue protocols [Slow Linear Oxidative Fatigue Protocol (SLO-FP) and Functional Agility Short-Term Fatigue Protocol (FAST-FP)]. Design Single-group repeated measures design. Methods Fifteen female collegiate soccer players had to perform five successful trials of unanticipated sidestep cutting (SS) pre- and post-fatigue protocols. The SLO-FP consisted of an initial VO2peak test followed by 5-min rest, and a 30-min interval run. The FAST-FP consisted of 4 sets of a functional circuit. Biomechanical measures of the hip and knee were obtained at different instants while performing SS pre- and post-fatigue. Repeated 2 × 2 ANOVAs were conducted to examine task and fatigue differences. Alpha level set a priori at 0.05. Results During the FAST-FP, participants had increased knee internal rotation at initial contact (IC) (12.5 ± 5.9°) when compared to the SLO-FP (7.9 ± 5.4°, p < 0.001). For hip flexion at IC, pre-fatigue had increased angles (36.4 ± 8.4°) compared to post-fatigue (30.4 ± 9.3°, p = 0.003), also greater knee flexion during pre-fatigue (25.6 ± 6.8°) than post-fatigue (22.4 ± 8.4°, p = 0.022). Conclusion The results of this study showed that hip and knee mechanics were substantially altered during both fatigue conditions. PMID:21636322

  18. Cine MR imaging of internal derangements of the knee

    International Nuclear Information System (INIS)

    Niitsu, M.; Anno, I.; Ishikawa, N.; Akisada, M.; Fukubayashi, T.

    1990-01-01

    This paper assesses internal derangements of the knee joint by a new method of cine MR imaging. Cine MR imaging, involving cine acquisition of kinematic sagittal images during knee movement, was used to evaluate 51 symptomatic patients and 19 healthy subjects. Cine MR images of cruciate ligament fears showed disappearance of low-intensity bundles during knee movement, periodic appearance of joint fluid in the area of the ligament, and irregular tibial movement. Cine MR images of meniscal tears showed independent movement of meniscal fragments and periodic tear opening and closing. Twenty-seven of the 28 anterior cruciate ligament (ACL) tears confirmed arthroscopically were correctly identified with cine MR imaging, with a sensitivity of 96% and a specificity of 92%

  19. Anterior sagittal transanorectal approach to the posterior urethra in the pediatric age group.

    Science.gov (United States)

    Rossi, F; De Castro, R; Ceccarelli, P L; Dòmini, R

    1998-09-01

    Surgical access to the posterior urethra is often difficult and several surgical solutions have been proposed. We suggest an anterior sagittal transanorectal approach based on splitting the anterior rectal wall only. This alternative technique provides excellent exposure to the retrourethral region, permitting simple and safe surgery. Between 1994 and 1996 we performed surgery via the anterior sagittal transanorectal approach in 8 patients with a mean age of 9.06 years. Patients included 1 girl with a posttraumatic urethrovaginal fistula, 3 with intersex disorders (2 with mixed gonadal dysgenesis raised as boys and 1 with male dysgenetic pseudohermaphroditism with an enlarged urtricle) and 4 boys (1 with penile agenesis raised as girl, 2 with urethral duplication and 1 with prostatic rhabdomyosarcoma). The patient was placed in a knee-chest position. A midline sagittal incision was made through the anterior anorectal wall only and deepened through the perineal body to expose the posterior urethra and retrovesical space. After the pathological condition was corrected the anterior rectal wall and perineal body were reconstructed. The operation was completed with protective colostomy. In our final patient with prostatic rhabdomyosarcoma the anterior sagittal transanorectal approach was used without colostomy. Anorectal manometry was done 6 months postoperatively. All patients were completely continent of stool and urine. Convalescence was unremarkable in all cases. Postoperative manometry in 7 patients revealed no differences from preoperative measurements. This procedure should be considered a useful alternative to other techniques for various congenital and acquired pelvic disorders.

  20. Possibilities and limitations of novel in-vitro knee simulator.

    Science.gov (United States)

    Verstraete, Matthias A; Victor, Jan

    2015-09-18

    The ex-vivo evaluation of knee kinematics remains vital to understand the impact of surgical treatments such as total knee arthroplasty (TKA). To that extent, knee simulators have been developed. However, these simulators have mainly focused on the simulation of a squatting motion. The relevance of this motion pattern for patients' activities of daily living is however questionable as squatting is difficult for elderly patients. Walking, stairs and cycling are more relevant motion patterns. This paper presents the design and control of a simulator that allows to independently control the applied kinematic and kinetic boundary conditions to simulate these daily life activities. Thereby, the knee is left with five degrees of freedom; only the knee flexion is actively controlled. From a kinetic point of view, the quadriceps and hamstring muscles are loaded. Optionally, a varus/valgus moment can be applied, facilitating a dynamic evaluation of the knee's stability. The simulator is based on three control loops, whose synchronization appears satisfactory. The input for these control loops can be determined from either musculoskeletal simulations or in accordance to literature data for traditional knee simulators. This opens the door towards an improved understanding of the knee biomechanics and comparison between different applied motion and force patterns. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Does shoe heel design influence ground reaction forces and knee moments during maximum lunges in elite and intermediate badminton players?

    Science.gov (United States)

    Lam, Wing-Kai; Ryue, Jaejin; Lee, Ki-Kwang; Park, Sang-Kyoon; Cheung, Jason Tak-Man; Ryu, Jiseon

    2017-01-01

    Lunge is one frequently executed movement in badminton and involves a unique sagittal footstrike angle of more than 40 degrees at initial ground contact compared with other manoeuvres. This study examined if the shoe heel curvature design of a badminton shoe would influence shoe-ground kinematics, ground reaction forces, and knee moments during lunge. Eleven elite and fifteen intermediate players performed five left-forward maximum lunge trials with Rounded Heel Shoe (RHS), Flattened Heel Shoe (FHS), and Standard Heel Shoes (SHS). Shoe-ground kinematics, ground reaction forces, and knee moments were measured by using synchronized force platform and motion analysis system. A 2 (Group) x 3 (Shoe) ANOVA with repeated measures was performed to determine the effects of different shoes and different playing levels, as well as the interaction of two factors on all variables. Shoe effect indicated that players demonstrated lower maximum vertical loading rate in RHS than the other two shoes (P badminton lunge. The differences in impact loads and knee moments between elite and intermediate players may be useful in optimizing footwear design and training strategy to minimize the potential risks for impact related injuries in badminton.

  2. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-01-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane. Key points An increased shoe collar height effectively reduced ankle joint ROM in the sagittal plane in weight-bearing dorsiflexion maneuver. Shoe collar height did not affect sagittal plane ankle kinematics and had no effect on performance during realistic jumping. Shoe collar height can affect the ankle plantarflexion torque and peak power during the push-off phase in lay-up jump. PMID:29238255

  3. Comparing the Effects of Therapeutic Exercise and Hydrotherapy on Pain Severity and Knee Range of Motion in Patients with Hemophilia: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    V Mazloum

    2013-10-01

    . Results: Both experimental groups exhibited significant reduction of pain along with improved knee flexion and extension compared with the control group (P<0.001. Pain reduction in subjects treated in water treatment was significantly higher than exercise group in drought (P0.05. Conclusion: The use of therapeutic exercise in water with regular exercise rehabilitation for patients with hemophilia can be helpful to reduce pain and improve range of motion in hemophilia patients. The effect of exercise therapy on pain reduction is more effective compared to traditional pain therapy. Key words: Hydrotherapy, Exercise Therapy, Hemophilia, Knee Range of Motion

  4. Male and female runners demonstrate different sagittal plane mechanics as a function of static hamstring flexibility

    Science.gov (United States)

    Williams III, D. S. Blaise; Welch, Lee M.

    2015-01-01

    ABSTRACT Background: Injuries to runners are common. However, there are many potential contributing factors to injury. While lack of flexibility alone is commonly related to injury, there are clear differences in hamstring flexibility between males and females. Objective: To compare the effect of static hamstring length on sagittal plane mechanics between male and female runners. Method: Forty subjects (30.0±6.4 years) participated and were placed in one of 4 groups: flexible males (n=10), inflexible males (n=10), flexible females (n=10), and inflexible females (n=10). All subjects were free of injury at the time of data collection. Three-dimensional kinematics and kinetics were collected while subjects ran over ground across 2 force platforms. Sagittal plane joint angles and moments were calculated at the knee and hip and compared with a 2-way (sex X flexibility) ANOVA (α=0.05). Results: Males exhibited greater peak knee extension moment than females (M=2.80±0.47, F=2.48±0.52 Nm/kg*m, p=0.05) and inflexible runners exhibited greater peak knee extension moment than flexible runners (In=2.83±0.56, Fl=2.44±0.51 Nm/kg*m, p=0.01). For hip flexion at initial contact, a significant interaction existed (pHamstring flexibility results in different mechanical profiles in males and females. Flexibility in the hamstrings may result in decreased moments via active or passive tension. These differences may have implications for performance and injury in flexible female runners. PMID:26537812

  5. Case-control study to estimate the performance of dual-energy computed tomography for anterior cruciate ligament tears in patients with history of knee trauma

    Energy Technology Data Exchange (ETDEWEB)

    Glazebrook, Katrina N.; Leng, Shuai; Murthy, Naveen S.; Howe, B.M.; Ringler, Michael D.; McCollough, Cynthia H.; Fletcher, J.G. [Mayo Clinic, Department of Radiology, Rochester, MN (United States); Brewerton, Lee J. [Alberta Health Services South Zone, Department of Radiology, Lethbridge, Alberta (Canada); Carter, Rickey E. [Mayo Clinic, Department of Biostatistics, Rochester, MN (United States); Rhee, Peter C.; Dahm, Diane L.; Stuart, Michael J. [Mayo Clinic, Department of Orthopedics, Rochester, MN (United States)

    2014-03-15

    Computed tomography (CT) is used to assess for fracture after knee trauma, but identification of ligamentous injuries may also be beneficial. Our purpose is to assess the potential of dual-energy computed tomography (DECT) for the detection of complete anterior cruciate ligament (ACL) disruption. Sixteen patients with unilateral traumatic ACL disruption (average of 58 days following trauma) confirmed by MRI, and 11 control patients without trauma, underwent DECT of both knees. For each knee, axial, sagittal, and oblique sagittal images (with DECT bone removal, single-energy (SE) bone removal, and DECT tendon-specific color mapping) were reconstructed. Four musculoskeletal radiologists randomly evaluated the 324 DECT reconstructed series (54 knees with 6 displays) separately, to assess for ACL disruption using a five-point scale (1 = definitely not torn, to 5 = definitely torn). ROC analysis was used to compare performance across readers and displays. Sagittal oblique displays (mixed kV soft tissue, SE bone removal, and DECT bone removal) demonstrated higher areas under the curve for ACL disruption (AUC = 0.95, 0.93 and 0.95 respectively) without significant differences in performance between readers (p > 0.23). Inter-reader agreement was also better for these display methods (ICC range 0.62-0.69) compared with other techniques (ICC range 0.41-0.57). Mean sensitivity for ACL disruption was worst for DECT tendon-specific color map and axial images (24 % and 63 % respectively). DECT knee images with oblique sagittal reconstructions using either mixed kV or bone removal displays (either DECT or SE) depict ACL disruption in the subacute or chronic setting with reliable identification by musculoskeletal radiologists. (orig.)

  6. Global Rating Scales and Motion Analysis Are Valid Proficiency Metrics in Virtual and Benchtop Knee Arthroscopy Simulators.

    Science.gov (United States)

    Chang, Justues; Banaszek, Daniel C; Gambrel, Jason; Bardana, Davide

    2016-04-01

    Work-hour restrictions and fatigue management strategies in surgical training programs continue to evolve in an effort to improve the learning environment and promote safer patient care. In response, training programs must reevaluate how various teaching modalities such as simulation can augment the development of surgical competence in trainees. For surgical simulators to be most useful, it is important to determine whether surgical proficiency can be reliably differentiated using them. To our knowledge, performance on both virtual and benchtop arthroscopy simulators has not been concurrently assessed in the same subjects. (1) Do global rating scales and procedure time differentiate arthroscopic expertise in virtual and benchtop knee models? (2) Can commercially available built-in motion analysis metrics differentiate arthroscopic expertise? (3) How well are performance measures on virtual and benchtop simulators correlated? (4) Are these metrics sensitive enough to differentiate by year of training? A cross-sectional study of 19 subjects (four medical students, 12 residents, and three staff) were recruited and divided into 11 novice arthroscopists (student to Postgraduate Year [PGY] 3) and eight proficient arthroscopists (PGY 4 to staff) who completed a diagnostic arthroscopy and loose-body retrieval in both virtual and benchtop knee models. Global rating scales (GRS), procedure times, and motion analysis metrics were used to evaluate performance. The proficient group scored higher on virtual (14 ± 6 [95% confidence interval {CI}, 10-18] versus 36 ± 5 [95% CI, 32-40], p virtual scope (579 ±169 [95% CI, 466-692] versus 358 ± 178 [95% CI, 210-507] seconds, p = 0.02) and benchtop knee scope + probe (480 ± 160 [95% CI, 373-588] versus 277 ± 64 [95% CI, 224-330] seconds, p = 0.002). The built-in motion analysis metrics also distinguished novices from proficient arthroscopists using the self-generated virtual loose body retrieval task scores (4 ± 1 [95% CI, 3

  7. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Directory of Open Access Journals (Sweden)

    Yang Yang, Ying Fang, Xini Zhang, Junliang He, Weijie Fu

    2017-12-01

    Full Text Available The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively performed a weight-bearing dorsiflexion (WB-DF maneuver, drop jumps (DJs, and lay-up jumps (LJs. Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041 was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028 and power (p = 0.022 were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  8. Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?

    Science.gov (United States)

    Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie

    2017-12-01

    The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion-extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane.

  9. MRI findings of the knee in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Kanno, Hiromasa; Yuasa, Shoichi; Choukan, Toshinori; Oonuma, Shinichi; Matsunaga, Toshiki

    1996-01-01

    The studies were done to know in what extent MRI can image the pannus invasion and cysts in the subcartilagious tissues which are not revealed by the scout roentgenogram and how the synovial membrane can be enhanced by gadolinium-DTPA (Gd-DTPA). Twenty five knees in rheumatoid arthritis of 21 patients, mean age of 57.8 years, were subjected to the studies. Thirteen knees were in Larsen grade 0, 3 in grade I, 4 in grade II, 2 in grade III and 3 in grade IV, whose osteolytic degree were small. MRI system was 0.5 Tesla superconducting Toshiba MRT50A. Imaging was performed by the field echo method with 4 mm-thick slice of T1, T2 weighted images of sagittal and frontal sections, and 5 min after intravenous injection of Gd-DTPA, of T1 weighted images of frontal and sagittal sections. Subcartilagious cysts not detectable on the scout roentgenogram were found in 13 knees (52%) on the MRI image. MRI after Gd-DTPA gave the enhanced images of surroundings of joint capsule in 15 cases, of dotted or reticular synovial membrane in 2 and of joint capsule surroundings with dotted membrane in 2. One case showed no enhancement. MRI was thus found useful for detection of cysts and pannus in the early knee rheumatoid arthritis with insignificant osteolysis. MRI after Gd-DTPA enhanced the surroundings of joint capsule in most cases, and in some cases, the synovial membrane in a dotted or reticular manner, which was considered to show the dilated blood vessels or necrotic coagulations of synovial villi. (H.O.)

  10. MRI findings of the knee in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kanno, Hiromasa; Yuasa, Shoichi; Choukan, Toshinori; Oonuma, Shinichi; Matsunaga, Toshiki [Jusendo General Hospital, Koriyama, Fukushima (Japan)

    1996-03-01

    The studies were done to know in what extent MRI can image the pannus invasion and cysts in the subcartilagious tissues which are not revealed by the scout roentgenogram and how the synovial membrane can be enhanced by gadolinium-DTPA (Gd-DTPA). Twenty five knees in rheumatoid arthritis of 21 patients, mean age of 57.8 years, were subjected to the studies. Thirteen knees were in Larsen grade 0, 3 in grade I, 4 in grade II, 2 in grade III and 3 in grade IV, whose osteolytic degree were small. MRI system was 0.5 Tesla superconducting Toshiba MRT50A. Imaging was performed by the field echo method with 4 mm-thick slice of T1, T2 weighted images of sagittal and frontal sections, and 5 min after intravenous injection of Gd-DTPA, of T1 weighted images of frontal and sagittal sections. Subcartilagious cysts not detectable on the scout roentgenogram were found in 13 knees (52%) on the MRI image. MRI after Gd-DTPA gave the enhanced images of surroundings of joint capsule in 15 cases, of dotted or reticular synovial membrane in 2 and of joint capsule surroundings with dotted membrane in 2. One case showed no enhancement. MRI was thus found useful for detection of cysts and pannus in the early knee rheumatoid arthritis with insignificant osteolysis. MRI after Gd-DTPA enhanced the surroundings of joint capsule in most cases, and in some cases, the synovial membrane in a dotted or reticular manner, which was considered to show the dilated blood vessels or necrotic coagulations of synovial villi. (H.O.)

  11. TREATMENT OF DEEP PERIPROSTHETIC INFECTION OF KNEE JOINT

    Directory of Open Access Journals (Sweden)

    Ivantsov V. A.

    2018-03-01

    Full Text Available In connection with the increase in arthroplasty of joints, the problem of infectious complications becomes topical. The aim of the study was to increase the effectiveness of purulent complications treatment after total knee arthroplasty. Material and methods. Treatment of patients with deep periprosthetic infection of the knee joint dealt with surgical debridement with the preservation of endoprosthesis, its removal and placement of a cement spacer or with the removal of endoprosthesis and arthrodesis of the knee joint. Surgical debridement was related to the radical excision of necrotic tissues and the remains of the synovial membrane. To prepare the cement spacer bone cement "CEMFIX" or "GENTAFIX" impregnated with antibiotic was used. For arthrodesis of the knee joint, Medbiotech core apparatus (the Republic of Belarus superimposed on the limb in the frontal and sagittal planes was applied. Results. The use of a differentiated and individual approach to the treatment of deep periprosthetic infection of the knee joint enabled to obtain positive results in 85.6% of cases. Conclusions. The two-stage method of treatment of deep periprosthetic infection of the knee joint is preferred, as compared to a one-stage method, which enables to obtain better results.

  12. Three-dimensional kinematic and kinetic gait deviations in individuals with chronic anterior cruciate ligament deficient knee: A systematic review and meta-analysis.

    Science.gov (United States)

    Ismail, Shiek Abdullah; Button, Kate; Simic, Milena; Van Deursen, Robert; Pappas, Evangelos

    2016-06-01

    Altered joint motion that occurs in people with an anterior cruciate ligament deficient knee is proposed to play a role in the initiation of knee osteoarthritis, however, the exact mechanism is poorly understood. Although several studies have investigated gait deviations in individuals with chronic anterior cruciate ligament deficient knee in the frontal and transverse planes, no systematic review has summarized the kinematic and kinetic deviations in these two planes. We searched five electronic databases from inception to 14th October 2013, with key words related to anterior cruciate ligament, biomechanics and gait, and limited to human studies only. Two independent reviewers assessed eligibility based on predetermined inclusion/exclusion criteria and methodological quality was evaluated using the Strengthening the Reporting of Observational Studies in Epidemiology statement checklist. We identified 16 studies, totaling 183 subjects with anterior cruciate ligament deficient knee and 211 healthy subjects. Due to the variability in reported outcomes, we could only perform meta-analysis for 13 sagittal plane outcomes. The only significant finding from our meta-analysis showed that individuals with anterior cruciate ligament deficient knee demonstrated a significantly greater external hip flexor angular impulse compared to control (P=0.03). No consensus about what constitutes a typical walking pattern in individuals with anterior cruciate ligament deficient knee can be made, nor can conclusions be derived to explain if gait deviations in the frontal and transverse plane contributed to the development of the knee osteoarthritis among this population. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Sagittal plane gait characteristics in hip osteoarthritis patients with mild to moderate symptoms compared to healthy controls: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Eitzen Ingrid

    2012-12-01

    Full Text Available Abstract Background Existent biomechanical studies on hip osteoarthritic gait have primarily focused on the end stage of disease. Consequently, there is no clear consensus on which specific gait parameters are of most relevance for hip osteoarthritis patients with mild to moderate symptoms. The purpose of this study was to explore sagittal plane gait characteristics during the stance phase of gait in hip osteoarthritis patients not eligible for hip replacement surgery. First, compared to healthy controls, and second, when categorized into two subgroups of radiographic severity defined from a minimal joint space of ≤/>2 mm. Methods Sagittal plane kinematics and kinetics of the hip, knee and ankle joint were calculated for total joint excursion throughout the stance phase, as well as from the specific events initial contact, midstance, peak hip extension and toe-off following 3D gait analysis. In addition, the Western Ontario and McMaster Universities Osteoarthritis Index, passive hip range of motion, and isokinetic muscle strength of hip and knee flexion and extension were included as secondary outcomes. Data were checked for normality and differences evaluated with the independent Student’s t-test, Welch’s t-test and the independent Mann–Whitney U-test. A binary logistic regression model was used in order to control for velocity in key variables. Results Fourty-eight hip osteoarthritis patients and 22 controls were included in the final material. The patients walked significantly slower than the controls (p=0.002, revealed significantly reduced joint excursions of the hip (pp=0.011, and a reduced hip flexion moment at midstance and peak hip extension (p2 mm suggested that the observed deviations were more pronounced in patients with greater radiographic severity. The biomechanical differences were, however, not reflected in self-reported symptoms or function. Conclusions Reduced gait velocity, reduced sagittal plane joint excursion, and

  14. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    International Nuclear Information System (INIS)

    Tuite, M.J.; Asinger, D.; Orwin, J.F.

    2001-01-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  15. Angled oblique sagittal MR imaging of rotator cuff tears: comparison with standard oblique sagittal images

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J; Asinger, D; Orwin, J F [Dept. of Radiology, Univ. of Wisconsin Hospital and Clinics, Madison, WI (United States)

    2001-05-01

    Objective. To compare the accuracy for diagnosing rotator cuff tears of oblique coronal images supplemented with standard oblique sagittal images versus thinner-section angled oblique sagittal images.Design and patients. The study included 75 consecutive patients who had a shoulder MR scan followed by arthroscopy. MR images included oblique coronal, oblique sagittal (4 mm thick, 1 mm interslice gap), and angled oblique sagittal (3 mm/0.2 mm) images perpendicular to the lateral cuff. A musculoskeletal staff radiologist and fellow separately evaluated the cuff for tears on the oblique coronal images supplemented with either the oblique sagittal or the angled sagittal images.Results. For distinguishing a cuff tear from no tear, the staff radiologist had an accuracy of 0.76 (95% confidence interval: 0.67, 0.85) with the standard sagittal set, and 0.88 (0.80, 0.95) with the angled set (P=0.04). There was a nonsignificant improvement in accuracy for the fellow, calculated as 0.73 (0.63, 0.83) on the standard sagittal set and 0.76 (0.67, 0.85) on the angled set. Both readers also improved their diagnostic accuracy for partial-thickness tears with the angled set, although the improvement was statistically significant only for the staff radiologist.Conclusion. There is a slight improvement in accuracy for diagnosing rotator cuff tears, particularly partial-thickness tears, for the more experienced radiologist using thinner-section angled oblique sagittal images. These images may be useful as a supplemental sequence in patients where it is important to identify partial-thickness tears accurately. (orig.)

  16. The role of knee joint moments and knee impairments on self-reported knee pain during gait in patients with knee osteoarthritis.

    Science.gov (United States)

    O'Connell, Megan; Farrokhi, Shawn; Fitzgerald, G Kelley

    2016-01-01

    The association between high mechanical knee joint loading during gait with onset and progression of knee osteoarthritis has been extensively studied. However, less attention has been given to risk factors related to increased pain during gait. The purpose of this study was to evaluate knee joint moments and clinical characteristics that may be associated with gait-related knee pain in patients with knee osteoarthritis. Sixty-seven participants with knee osteoarthritis were stratified into three groups of no pain (n=18), mild pain (n=27), or moderate/severe pain (n=22) based on their self-reported symptoms during gait. All participants underwent three-dimensional gait analysis. Quadriceps strength, knee extension range of motion, radiographic knee alignment and self-reported measures of global pain and function were also quantified. The moderate/severe pain group demonstrated worse global pain (Pknee flexion moments during the midstance phase of gait compared to the no pain group (P=0.02). Additionally, the moderate/severe pain group demonstrated greater varus knee malalignment (P=0.009), which was associated with higher weight acceptance peak knee adduction moments (P=0.003) and worse global pain (P=0.003) and physical function scores (P=0.006). Greater knee flexion moment is present during the midstance phase of gait in patients with knee osteoarthritis and moderate/severe pain during gait. Additionally, greater varus malalignment may be a sign of increased global knee joint dysfunction that can influence many activities of daily living beyond gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Comparison of robot surgery modular and total knee arthroplasty kinematics.

    Science.gov (United States)

    Yildirim, Gokce; Fernandez-Madrid, Ivan; Schwarzkopf, Ran; Walker, Peter S; Karia, Raj

    2014-04-01

    The kinematics of seven knee specimens were measured from 0 to 120 degrees flexion using an up-and-down crouching machine. Motion was characterized by the positions of the centers of the lateral and medial femoral condyles in the anterior-posterior direction relative to a fixed tibia. A modular unicompartmental knee, trochlea flange, and patella resurfacing (multicompartmental knee [MCK] system) were implanted using a surgeon-interactive robot system that provided accurate surface matching. The MCK was tested, followed by standard cruciate retaining (CR) and posterior stabilized (PS) knees. The motion of the MCK was close to anatomic, especially on the medial side, in contrast to the CR and PS knees that showed abnormal motion features. Such a modular knee system, accurately inserted, has the potential for close to normal function in clinical application. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Hip joint biomechanics in those with and without post-traumatic knee osteoarthritis after anterior cruciate ligament injury.

    Science.gov (United States)

    Wellsandt, E; Zeni, J A; Axe, M J; Snyder-Mackler, L

    2017-12-01

    Anterior cruciate ligament injury results in altered kinematics and kinetics in the knee and hip joints that persist despite surgical reconstruction and rehabilitation. Abnormal movement patterns and a history of osteoarthritis are risk factors for articular cartilage degeneration in additional joints. The purpose of this study was to determine if hip joint biomechanics early after anterior cruciate ligament injury and reconstruction differ between patients with and without post-traumatic knee osteoarthritis 5years after reconstruction. The study's rationale was that individuals who develop knee osteoarthritis after anterior cruciate ligament injury may also demonstrate large alterations in hip joint biomechanics. Nineteen athletes with anterior cruciate ligament injury completed standard gait analysis before (baseline) and after (post-training) extended pre-operative rehabilitation and at 6months, 1year, and 2years after reconstruction. Weightbearing knee radiographs were completed 5years after reconstruction to identify medial compartment osteoarthritis. Five of 19 patients had knee osteoarthritis at 5years after anterior cruciate ligament reconstruction. Patients with knee osteoarthritis at 5years walked with smaller sagittal plane hip angles (P: 0.043) and lower sagittal (P: 0.021) and frontal plane (P: 0.042) external hip moments in the injured limb before and after reconstruction compared to those without knee osteoarthritis. The current findings suggest hip joint biomechanics may be altered in patients who develop post-traumatic knee osteoarthritis. Further study is needed to confirm whether the risk of non-traumatic hip pathology is increased after anterior cruciate ligament injury and if hip joint biomechanics influence its development. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Effectiveness of prolonged use of continuous passive motion (CPM, as an adjunct to physiotherapy, after total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Geesink Ruud JT

    2008-04-01

    Full Text Available Abstract Background Adequate and intensive rehabilitation is an important requirement for successful total knee arthroplasty. Although research suggests that Continuous Passive Motion (CPM should be implemented in the first rehabilitation phase after surgery, there is substantial debate about the duration of each session and the total period of CPM application. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. Methods In a randomised controlled trial we investigated the effectiveness of prolonged CPM use in the home situation as an adjunct to standardised PT. Efficacy was assessed in terms of faster improvements in range of motion (RoM and functional recovery, measured at the end of the active treatment period, 17 days after surgery. Sixty patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment were randomised over two treatment groups. The experimental group received CPM + PT for 17 consecutive days after surgery, whereas the usual care group received the same treatment during the in-hospital phase (i.e. about four days, followed by PT alone (usual care in the first two weeks after hospital discharge. From 18 days to three months after surgery, both groups received standardised PT. The primary focus of rehabilitation was functional recovery (e.g. ambulation and regaining RoM in the knee. Results Prolonged use of CPM slightly improved short-term RoM in patients with limited RoM at the time of discharge after total knee arthroplasty when added to a semi-standard PT programme. Assessment at 6 weeks and three months after surgery found no long-term effects of this intervention Neither did we detect functional benefits of the improved RoM at any of the outcome assessments. Conclusion Although results

  20. Effectiveness of prolonged use of continuous passive motion (CPM), as an adjunct to physiotherapy, after total knee arthroplasty

    Science.gov (United States)

    Lenssen, Ton AF; van Steyn, Mike JA; Crijns, Yvonne HF; Waltjé, Eddie MH; Roox, George M; Geesink, Ruud JT; Brandt, Piet A van den; De Bie, Rob A

    2008-01-01

    Background Adequate and intensive rehabilitation is an important requirement for successful total knee arthroplasty. Although research suggests that Continuous Passive Motion (CPM) should be implemented in the first rehabilitation phase after surgery, there is substantial debate about the duration of each session and the total period of CPM application. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. Methods In a randomised controlled trial we investigated the effectiveness of prolonged CPM use in the home situation as an adjunct to standardised PT. Efficacy was assessed in terms of faster improvements in range of motion (RoM) and functional recovery, measured at the end of the active treatment period, 17 days after surgery. Sixty patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment were randomised over two treatment groups. The experimental group received CPM + PT for 17 consecutive days after surgery, whereas the usual care group received the same treatment during the in-hospital phase (i.e. about four days), followed by PT alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after surgery, both groups received standardised PT. The primary focus of rehabilitation was functional recovery (e.g. ambulation) and regaining RoM in the knee. Results Prolonged use of CPM slightly improved short-term RoM in patients with limited RoM at the time of discharge after total knee arthroplasty when added to a semi-standard PT programme. Assessment at 6 weeks and three months after surgery found no long-term effects of this intervention Neither did we detect functional benefits of the improved RoM at any of the outcome assessments. Conclusion Although results indicate that prolonged CPM use

  1. Effectiveness of prolonged use of continuous passive motion (CPM), as an adjunct to physiotherapy, after total knee arthroplasty.

    Science.gov (United States)

    Lenssen, Ton A F; van Steyn, Mike J A; Crijns, Yvonne H F; Waltjé, Eddie M H; Roox, George M; Geesink, Ruud J T; van den Brandt, Piet A; De Bie, Rob A

    2008-04-29

    Adequate and intensive rehabilitation is an important requirement for successful total knee arthroplasty. Although research suggests that Continuous Passive Motion (CPM) should be implemented in the first rehabilitation phase after surgery, there is substantial debate about the duration of each session and the total period of CPM application. A Cochrane review on this topic concluded that short-term use of CPM leads to greater short-term range of motion. It also suggested, however, that future research should concentrate on the treatment period during which CPM should be administered. In a randomised controlled trial we investigated the effectiveness of prolonged CPM use in the home situation as an adjunct to standardised PT. Efficacy was assessed in terms of faster improvements in range of motion (RoM) and functional recovery, measured at the end of the active treatment period, 17 days after surgery. Sixty patients with knee osteoarthritis undergoing TKA and experiencing early postoperative flexion impairment were randomised over two treatment groups. The experimental group received CPM + PT for 17 consecutive days after surgery, whereas the usual care group received the same treatment during the in-hospital phase (i.e. about four days), followed by PT alone (usual care) in the first two weeks after hospital discharge. From 18 days to three months after surgery, both groups received standardised PT. The primary focus of rehabilitation was functional recovery (e.g. ambulation) and regaining RoM in the knee. Prolonged use of CPM slightly improved short-term RoM in patients with limited RoM at the time of discharge after total knee arthroplasty when added to a semi-standard PT programme. Assessment at 6 weeks and three months after surgery found no long-term effects of this intervention Neither did we detect functional benefits of the improved RoM at any of the outcome assessments. Although results indicate that prolonged CPM use might have a small short-term effect

  2. Temporal gene expression profiling of the rat knee joint capsule during immobilization-induced joint contractures.

    Science.gov (United States)

    Wong, Kayleigh; Sun, Fangui; Trudel, Guy; Sebastiani, Paola; Laneuville, Odette

    2015-05-26

    Contractures of the knee joint cause disability and handicap. Recovering range of motion is recognized by arthritic patients as their preference for improved health outcome secondary only to pain management. Clinical and experimental studies provide evidence that the posterior knee capsule prevents the knee from achieving full extension. This study was undertaken to investigate the dynamic changes of the joint capsule transcriptome during the progression of knee joint contractures induced by immobilization. We performed a microarray analysis of genes expressed in the posterior knee joint capsule following induction of a flexion contracture by rigidly immobilizing the rat knee joint over a time-course of 16 weeks. Fold changes of expression values were measured and co-expressed genes were identified by clustering based on time-series analysis. Genes associated with immobilization were further analyzed to reveal pathways and biological significance and validated by immunohistochemistry on sagittal sections of knee joints. Changes in expression with a minimum of 1.5 fold changes were dominated by a decrease in expression for 7732 probe sets occurring at week 8 while the expression of 2251 probe sets increased. Clusters of genes with similar profiles of expression included a total of 162 genes displaying at least a 2 fold change compared to week 1. Functional analysis revealed ontology categories corresponding to triglyceride metabolism, extracellular matrix and muscle contraction. The altered expression of selected genes involved in the triglyceride biosynthesis pathway; AGPAT-9, and of the genes P4HB and HSP47, both involved in collagen synthesis, was confirmed by immunohistochemistry. Gene expression in the knee joint capsule was sensitive to joint immobility and provided insights into molecular mechanisms relevant to the pathophysiology of knee flexion contractures. Capsule responses to immobilization was dynamic and characterized by modulation of at least three

  3. Early recovery after fast-track Oxford unicompartmental knee arthroplasty

    DEFF Research Database (Denmark)

    Munk, Stig; Dalsgaard, Jesper; Bjerggaard, Karin

    2012-01-01

    trauma. We investigated changes in leg-extension power (LEP) in the first month after MIS Oxford UKA and its relation to pain, knee motion, functional performance, and knee function. Patients and methods In 35 consecutive Oxford UKA patients, LEP was measured 1 week before and 1 month after surgery...... together with knee motion, knee swelling, the 30-second chair-stand test, and Oxford knee score. Assessment of knee pain at rest and walking was done using a visual analog scale. Results 30 patients were discharged on the day after surgery, and 5 on the second day after surgery. LEP and functional...... performance reached the preoperative level after 1 month. Only slight postoperative knee swelling was observed with rapid restoration of knee flexion and function. A high level of pain during the first postoperative night and day fell considerably thereafter. None of the patients needed physiotherapy...

  4. MR assessment of movement and morphologic change in the menisci during knee flexion

    International Nuclear Information System (INIS)

    Kawahara, Y.; Uetani, M.; Fuchi, K.; Eguchi, H.; Hayashi, K.

    1999-01-01

    To examine movement and morphologic alteration in the menisci during knee flexion. Twenty healthy knees were imaged at 0 degrees, 45 degrees, and 90 degrees of passive non-weight-bearing flexion in the sagittal plane with MR. In each meniscus, posterior movement distance during knee flexion and the ratio of anteroposterior (a.p.) diameter at flexion to that at extension were calculated. Each meniscus moved posteriorly during knee flexion. Movement was greater in the anterior horn than in the posterior horn, and greater in the medial meniscus than in the lateral meniscus (p<0.05). The a.p. diameter of each meniscus was reduced at flexion (p<0.05). Knee flexion normally leads to posterior movement and shortening of the a.p. diameter of the menisci, which may be related to the positioning and curvature of femoral condyles at the femorotibial contact point at knee flexion

  5. MR assessment of movement and morphologic change in the menisci during knee flexion

    International Nuclear Information System (INIS)

    Kawahara, Y.; Uetani, M.; Hayashi, K.; Fuchi, K.; Eguchi, H.

    1999-01-01

    Purpose: To examine movement and morphologic alteration in the menisci during knee flexion. Material and Methods: Twenty healthy knees were imaged at 0 , 45 , and 90 of passive non-weight-bearing flexion in the sagittal plane with MR. In each meniscus, posterior movement distance during knee flexion and the ratio of anteroposterior (a.p.) diameter at flexion to that at extension were calculated. Results: Each meniscus moved posteriorly during knee flexion. Movement was greater in the anterior horn than in the posterior horn, and greater in the medial meniscus than in the lateral meniscus (p<0.05). The a.p. diameter of each meniscus was reduced at flexion (p<0.05). Conclusion: Knee flexion normally leads to posterior movement and shortening of the a.p. diameter of the menisci, which may be related to the positioning and curvature of femoral condyles at the femorotibial contact point at knee flexion. (orig.)

  6. MR imaging of the knee in patients with rheumatic diseases

    International Nuclear Information System (INIS)

    Weissman, B.N.; Winalski, C.S.; Aliabadi, P.; Kikinis, R.; Shortkroff, S.; Sledge, C.B.

    1990-01-01

    This paper evaluates the MR appearances of the knees in patients with rheumatic diseases, including the grading of changes, quantification of changes, and the role of intravenous gadolinium. MR imaging of the knee was performed in 19 patients with arthritis, including rheumatoid arthritis (n = 11), juvenile rheumatoid arthritis (n = 2), Reiter syndrome (n = 2), Crohn arthritis (n = 1), and psoriatic arthritis (n = 3). Spin-echo images (T1, T2, and proton density weighted) were obtained in sagittal, coronal, and axial planes. T1-weighted axial images were obtained before and after intravenous injection of Gd-DTPA

  7. Clinical Outcomes in Men and Women following Total Knee Arthroplasty with a High-Flex Knee: No Clinical Effect of Gender.

    Science.gov (United States)

    Nassif, Jeffrey M; Pietrzak, William S

    2015-01-01

    While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based differences exist. We retrospectively compared the performance of the high-flex Vanguard knee (Biomet, Warsaw, IN) in 716 male and 1,069 female knees. Kaplan-Meier survivorship was 98.5% at 5.6-5.7 years for both genders. After 2 years, mean improvements in Knee Society Knee and Function scores for men and women (50.9 versus 46.3; 26.5 versus 23.1) and corresponding SF-12 Mental and Physical scores (0.2 versus 2.2; 13.7 versus 12.2) were similar with differences not clinically relevant. Postoperative motion gains as a function of preoperative motion level were virtually identical in men and women. This further confirms the suitability of unisex total knee prostheses for both men and women.

  8. Severe Heterotopic Ossification following Total Knee Replacement

    Directory of Open Access Journals (Sweden)

    Alexander L. Dodds

    2014-01-01

    Full Text Available Although the incidence of minor heterotopic ossification is probably higher than what is usually expected, severe heterotopic ossification (HO is an extremely rare event following total knee replacement surgery. We present the case of a 66-year-old woman who initially had achieved an excellent range of motion following bilateral uncemented rotating platform total knee replacement, before presenting with pain and loss of range of motion at 2 months after surgery. Severe HO was diagnosed on X-rays. Treatment consisted of nonoperative measures only, including physiotherapy with hydrotherapy and anti-inflammatories. She eventually regained her range of motion when seen at 8 months after operation. This case illustrates that nonoperative treatment without the use of radiotherapy or surgery can be used to safely resolve stiffness caused by HO after total knee replacement.

  9. Altered Knee and Ankle Kinematics During Squatting in Those With Limited Weight-Bearing–Lunge Ankle-Dorsiflexion Range of Motion

    Science.gov (United States)

    Dill, Karli E.; Begalle, Rebecca L.; Frank, Barnett S.; Zinder, Steven M.; Padua, Darin A.

    2014-01-01

    Context: Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. Objective: To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Design: Cross-sectional study. Setting: Sports medicine research laboratory. Patients or Other Participants: Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Main Outcome Measure(s): Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. Results: We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Conclusions: Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during

  10. Combined versus individual effects of a valgus knee brace and lateral wedge foot orthotic during stair use in patients with knee osteoarthritis.

    Science.gov (United States)

    Moyer, Rebecca; Birmingham, Trevor; Dombroski, Colin; Walsh, Robert; Giffin, J Robert

    2017-05-01

    The aim of this study was to investigate the combined and individual biomechanical effects of a valgus knee brace and a lateral wedge foot orthotic during stair ascent and descent in patients with knee osteoarthritis (OA). Thirty-five patients with varus alignment and medial knee OA were prescribed a custom valgus knee brace and lateral wedge foot orthotic. Knee angles and moments in the frontal and sagittal planes were determined from 3D gait analysis completed under four randomized conditions: (1) control (no knee brace or foot orthotic), (2) knee brace, (3) foot orthotic, and (4) combined knee brace and foot orthotic. Additional measures included the vertical ground reaction force, trunk lean, toe out and gait speed. During the combined use of a knee brace and foot orthotic, significant decreases in the knee adduction angle (2.17, 95%CI: 0.50-3.84, p=0.013) and 2nd peak EKAM (0.35, 95%CI: 0.17-0.52, pstair descent; and significant increases in the EKFM were observed during stair ascent (0.54, 95%CI: 0.30-0.78, pstair descent compared to ascent, except for toe out. Findings suggest greater effects on gait when both knee brace and foot orthotic are used together, resulting in a more normal gait pattern. However, whether or not a true change in knee joint load can be inferred when using these orthoses remains unclear. Further research is required to determine the clinical importance of the observed changes. Copyright © 2017. Published by Elsevier B.V.

  11. Effects of mid-foot contact area ratio on lower body kinetics/kinematics in sagittal plane during stair descent in women.

    Science.gov (United States)

    Lee, Jinkyu; Hong, Yoon No Gregory; Shin, Choongsoo S

    2016-07-01

    The mid-foot contact area relative to the total foot contact area can facilitate foot arch structure evaluation. A stair descent motion consistently provides initial fore-foot contact and utilizes the foot arch more actively for energy absorption. The purpose of this study was to compare ankle and knee joint angle, moment, and work in sagittal plane during stair descending between low and high Mid-Foot-Contact-Area (MFCA) ratio group. The twenty-two female subjects were tested and classified into two groups (high MFCA and low MFCA) using their static MFCA ratios. The ground reaction force (GRF) and kinematics of ankle and knee joints were measured while stair descending. During the period between initial contact and the first peak in vertical GRF (early absorption phase), ankle negative work for the low MFCA ratio group was 33% higher than that for the high MFCA ratio group (pcontact and peak dorsiflexion angle (early absorption phase+late absorption phase). The peak ankle dorsiflexion angle was smaller in the low MFCA ratio group (p<0.05). Our results suggest that strategy of energy absorption at the ankle and foot differs depending upon foot arch types classified by MFCA. The low MFCA ratio group seemed to absorb more impact energy using strain in the planar fascia during early absorption phase, whereas the high MFCA ratio group absorbed more impact energy using increased dorsiflexion during late absorption phase. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Assessment of knee laxity using a robotic testing device: a comparison to the manual clinical knee examination.

    Science.gov (United States)

    Branch, T P; Stinton, S K; Siebold, R; Freedberg, H I; Jacobs, C A; Hutton, W C

    2017-08-01

    The purpose of this study was to collect knee laxity data using a robotic testing device. The data collected were then compared to the results obtained from manual clinical examination. Two human cadavers were studied. A medial collateral ligament (MCL) tear was simulated in the left knee of cadaver 1, and a posterolateral corner (PLC) injury was simulated in the right knee of cadaver 2. Contralateral knees were left intact. Five blinded examiners carried out manual clinical examination on the knees. Laxity grades and a diagnosis were recorded. Using a robotic knee device which can measure knee laxity in three planes of motion: anterior-posterior, internal-external tibia rotation, and varus-valgus, quantitative data were obtained to document tibial motion relative to the femur. One of the five examiners correctly diagnosed the MCL injury. Robotic testing showed a 1.7° larger valgus angle, 3° greater tibial internal rotation, and lower endpoint stiffness (11.1 vs. 24.6 Nm/°) in the MCL-injured knee during varus-valgus testing when compared to the intact knee and 4.9 mm greater medial tibial translation during rotational testing. Two of the five examiners correctly diagnosed the PLC injury, while the other examiners diagnosed an MCL tear. The PLC-injured knee demonstrated 4.1 mm more lateral tibial translation and 2.2 mm more posterior tibial translation during varus-valgus testing when compared to the intact knee. The robotic testing device was able to provide objective numerical data that reflected differences between the injured knees and the uninjured knees in both cadavers. The examiners that performed the manual clinical examination on the cadaver knees proved to be poor at diagnosing the injuries. Robotic testing could act as an adjunct to the manual clinical examination by supplying numbers that could improve diagnosis of knee injury. Level II.

  13. Effect of trunk sagittal attitude on shoulder, thorax and pelvis three-dimensional kinematics in able-bodied subjects during gait.

    Directory of Open Access Journals (Sweden)

    Alberto Leardini

    Full Text Available It has been shown that an original attitude in forward or backward inclination of the trunk is maintained at gait initiation and during locomotion, and that this affects lower limb loading patterns. However, no studies have shown the extent to which shoulder, thorax and pelvis three-dimensional kinematics are modified during gait due to this sagittal inclination attitude. Thirty young healthy volunteers were analyzed during level walking with video-based motion analysis. Reflecting markers were mounted on anatomical landmarks to form a two-marker shoulder line segment, and a four-marker thorax and pelvis segments. Absolute and relative spatial rotations were calculated, for a total of 11 degrees of freedom. The subjects were divided into two groups of 15 according to the median of mean thorax inclination angle over the gait cycle. Preliminary MANOVA analysis assessed whether gender was an independent variable. Then two-factor nested ANOVA was used to test the possible effect of thorax inclination on body segments, planes of motion and gait periods, separately. There was no significant difference in all anthropometric and spatio-temporal parameters between the two groups, except for subject mass. The three-dimensional kinematics of the thorax and pelvis were not affected by gender. Nested ANOVA revealed group effect in all segment rotations apart those at the pelvis, in the sagittal and frontal planes, and at the push-off. Attitudes in sagittal thorax inclination altered trunk segments kinematics during gait. Subjects with a backward thorax showed less thorax-to-pelvis motion, but more shoulder-to-thorax and thorax-to-laboratory motion, less motion in flexion/extension and in lateral bending, and also less motion during push-off. This contributes to the understanding of forward propulsion and sideways load transfer mechanisms, fundamental for the maintenance of balance and the risk of falling.

  14. Tibial Eminence Involvement With Tibial Plateau Fracture Predicts Slower Recovery and Worse Postoperative Range of Knee Motion.

    Science.gov (United States)

    Konda, Sanjit R; Driesman, Adam; Manoli, Arthur; Davidovitch, Roy I; Egol, Kenneth A

    2017-07-01

    To examine 1-year functional and clinical outcomes in patients with tibial plateau fractures with tibial eminence involvement. Retrospective analysis of prospectively collected data. Academic Medical Center. All patients who presented with a tibial plateau fracture (Orthopaedic Trauma Association (OTA) 41-B and 41-C). Patients were divided into fractures with a tibial eminence component (+TE) and those without (-TE) cohorts. All patients underwent similar surgical approaches and fixation techniques for fractures. No tibial eminence fractures received fixation specifically. Short musculoskeletal functional assessment (SMFA), pain (Visual Analogue Scale), and knee range-of-motion (ROM) were evaluated at 3, 6, and 12 months postoperatively and compared between cohorts. Two hundred ninety-three patients were included for review. Patients with OTA 41-C fractures were more likely to have an associated TE compared with 41-B fractures (63% vs. 28%, P knee ROM (75.16 ± 51 vs. 86.82 ± 53 degree, P = 0.06). At 6 months, total SMFA and knee ROM was significantly worse in the +TE cohort (29 ± 17 vs. 21 ± 18, P ≤ 0.01; 115.6 ± 20 vs. 124.1 ± 15, P = 0.01). By 12 months postoperatively, only knee ROM remained significantly worse in the +TE cohort (118.7 ± 15 vs. 126.9 ± 13, P time points. Knee ROM remains worse throughout the postoperative period in the +TE cohort. Functional outcome improves less rapidly in the +TE cohort but achieves similar results by 1 year. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  15. Recruitment of knee joint ligaments

    NARCIS (Netherlands)

    Blankevoort, L.; Huiskes, H.W.J.; Lange, de A.

    1991-01-01

    On the basis of earlier reported data on the in vitro kinematics of passive knee-joint motions of four knee specimens, the length changes of ligament fiber bundles were determined by using the points of insertion on the tibia and femur. The kinematic data and the insertions of the ligaments were

  16. Biomechanical analysis of knee and trunk in badminton players with and without knee pain during backhand diagonal lunges.

    Science.gov (United States)

    Lin, Cheng-Feng; Hua, Shiang-Hua; Huang, Ming-Tung; Lee, Hsing-Hsan; Liao, Jen-Chieh

    2015-01-01

    The contribution of core neuromuscular control to the dynamic stability of badminton players with and without knee pain during backhand lunges has not been investigated. Accordingly, this study compared the kinematics of the lower extremity, the trunk movement, the muscle activation and the balance performance of knee-injured and knee-uninjured badminton players when performing backhand stroke diagonal lunges. Seventeen participants with chronic knee pain (injured group) and 17 healthy participants (control group) randomly performed two diagonal backhand lunges in the forward and backward directions, respectively. This study showed that the injured group had lower frontal and horizontal motions of the knee joint, a smaller hip-shoulder separation angle and a reduced trunk tilt angle. In addition, the injured group exhibited a greater left paraspinal muscle activity, while the control group demonstrated a greater activation of the vastus lateralis, vastus medialis and medial gastrocnemius muscle groups. Finally, the injured group showed a smaller distance between centre of mass (COM) and centre of pressure, and a lower peak COM velocity when performing the backhand backward lunge tasks. In conclusion, the injured group used reduced knee and trunk motions to complete the backhand lunge tasks. Furthermore, the paraspinal muscles contributed to the lunge performance of the individuals with knee pain, whereas the knee extensors and ankle plantar flexor played a greater role for those without knee pain.

  17. The use of the T1 sagittal angle in predicting overall sagittal balance of the spine.

    Science.gov (United States)

    Knott, Patrick T; Mardjetko, Steven M; Techy, Fernando

    2010-11-01

    A balanced sagittal alignment of the spine has been shown to strongly correlate with less pain, less disability, and greater health status scores. To restore proper sagittal balance, one must assess the position of the occiput relative to the sacrum. The assessment of spinal balance preoperatively can be challenging, whereas predicting postoperative balance is even more difficult. This study was designed to evaluate and quantify multiple factors that influence sagittal balance. Retrospective analysis of existing spinal radiographs. A retrospective review of 52 adult spine patient records was performed. All patients had full-column digital radiographs that showed all the important skeletal landmarks necessary for accurate measurement. The average age of the patient was 53 years. Both genders were equally represented. The radiographs were measured using standard techniques to obtain the following parameters: scoliosis in the coronal plane; lordosis or kyphosis of the cervical, thoracic, and lumbar spine; the T1 sagittal angle (angle between a horizontal line and the superior end plate of T1); the angle of the dens in the sagittal plane; the angle of the dens in relation to the occiput; the sacral slope; the pelvic incidence; the femoral-sacral angle; and finally, the sagittal vertical axis (SVA) measured from both the dens of C2 and from C7. It was found that the SVA when measured from the dens was on average 16 mm farther forward than the SVA measured from C7 (p<.0001). The dens plumb line (SVA(dens)) was then used in the study. An analysis was done to examine the relationship between SVA(dens) and each of the other measurements. The T1 sagittal angle was found to have a moderate positive correlation (r=0.65) with SVA(dens), p<.0001, indicating that the amount of sagittal T1 tilt can be used as a good predictor of overall sagittal balance. When examining the other variables, it was found that cervical lordosis had a weak correlation (r=0.37) with SVA(dens) that was

  18. The Relationships Between the Center of Mass Position and the Trunk, Hip, and Knee Kinematics in the Sagittal Plane: A Pilot Study on Field-Based Video Analysis for Female Soccer Players

    Directory of Open Access Journals (Sweden)

    Sasaki Shogo

    2015-03-01

    Full Text Available Athletes with non-contact anterior cruciate ligament tears have common features in the sagittal plane; namely, the body’s center of mass (COM is located posterior to the base of support, the trunk and knee joints are extended, and the hip angle is flexed. However, the relationships among these variables have not been assessed in field-based movements. This study sought to determine relationships between distances from the COM to the base of support and the trunk, hip, and knee positions in women while playing soccer. Sixty events (29 single-leg landing and 31 single-leg stopping events were analyzed using two-dimensional video analysis. The relationships among the measurement variables were determined using the Pearson’s product-moment correlation coefficient, and stepwise multiple linear regression models were used to explore the relationships between the COM position and the kinematic variables. The distance from the COM to the base of support displayed a moderate negative relationship with the trunk angle (r = - 0.623, p < .0001, r2 = 0.388 and a strong positive relationship with the limb angle (r = 0.869, p < .0001, r2 = 0.755. The limb, knee, and trunk angles were selected in the best regression model (adjusted r2 = 0.953, p < .0001, f2 = 20.277. These findings suggest that an increased trunk angle and a decreased limb angle at initial contact are associated with a safer COM position. Neuromuscular training may be useful for controlling the trunk and lower limb positions during dynamic activities.

  19. Sagittal plane tilting deformity of the patellofemoral joint: a new concept in patients with chondromalacia patella.

    Science.gov (United States)

    Aksahin, Ertugrul; Aktekin, Cem Nuri; Kocadal, Onur; Duran, Semra; Gunay, Cüneyd; Kaya, Defne; Hapa, Onur; Pepe, Murad

    2017-10-01

    The aims of this study were to evaluate sagittal plane alignment in patients with chondromalacia patella via magnetic resonance imaging (MRI), analyse the relationships between the location of the patellar cartilaginous lesions and sagittal alignment and finally investigate the relationships between the sagittal plane malalignment and patellofemoral loadings using by finite element analysis. Fifty-one patients who were diagnosed with isolated modified Outerbridge grade 3-4 patellar chondromalacia based on MRI evaluation and 51 control subjects were evaluated. Chondromalacia patella patients were divided into three subgroups according to the chondral lesion location as superior, middle and inferior. The patella-patellar tendon angle (P-PT) was used for evaluation of sagittal alignment of patellofemoral joint. Each subgroup was compared with control group by using P-PT angle. To investigate the biomechanical effects of sagittal plane malpositioning on patellofemoral joint, bone models were created at 30°, 60° and 90° knee flexion by using mean P-PT angles, which obtained from patients with chondromalacia patellae and control subjects. The total loading and contact area values of the patellofemoral joints were investigated by finite element analysis. The mean age of all participants was 52.9 ± 8.2 years. The mean P-PT angle was significantly lower in chondromalacia group (142.1° ± 3.6°) compared to control group (144.5° ± 5.3°) (p = 0.008). Chondral lesions were located in superior, middle and inferior zones in 16, 20 and 15 patients, respectively. The mean P-PT angles in patients with superior (141.8 ± 2.7) and inferior subgroups (139.2 ± 2.3) were significantly lower than the values in the control group (p chondromalacia than in the control models at the same flexion degrees. There were increased loadings at 30° and 90° flexions in the sagittal patellar tilt models. This study revealed that sagittal plain malpositioning of the

  20. Clinical Outcomes in Men and Women following Total Knee Arthroplasty with a High-Flex Knee: No Clinical Effect of Gender

    Directory of Open Access Journals (Sweden)

    Jeffrey M. Nassif

    2015-01-01

    Full Text Available While it is generally recognized that anatomical differences exist between the male and female knee, the literature generally refutes the clinical need for gender-specific total knee prostheses. It has been found that standard, unisex knees perform as well, or better, in women than men. Recently, high-flex knees have become available that mechanically accommodate increased flexion yet no studies have directly compared the outcomes of these devices in men and women to see if gender-based differences exist. We retrospectively compared the performance of the high-flex Vanguard knee (Biomet, Warsaw, IN in 716 male and 1,069 female knees. Kaplan-Meier survivorship was 98.5% at 5.6–5.7 years for both genders. After 2 years, mean improvements in Knee Society Knee and Function scores for men and women (50.9 versus 46.3; 26.5 versus 23.1 and corresponding SF-12 Mental and Physical scores (0.2 versus 2.2; 13.7 versus 12.2 were similar with differences not clinically relevant. Postoperative motion gains as a function of preoperative motion level were virtually identical in men and women. This further confirms the suitability of unisex total knee prostheses for both men and women.

  1. A DYNAMIC VALGUS INDEX THAT COMBINES HIP AND KNEE ANGLES: ASSESSMENT OF UTILITY IN FEMALES WITH PATELLOFEMORAL PAIN.

    Science.gov (United States)

    Scholtes, Sara A; Salsich, Gretchen B

    2017-06-01

    Two=dimensional motion analysis of lower=extremity movement typically focuses on the knee frontal plane projection angle, which considers the position of the femur and the tibia. A measure that includes the pelvis may provide a more comprehensive and accurate indicator of lower=extremity movement. Hypothesis/Purpose: The purpose of the study was to describe the utility of a two=dimensional dynamic valgus index (DVI) in females with patellofemoral pain. The hypothesis was that the DVI would be more reliable and valid than the knee frontal plane projection angle, be greater in females with patellofemoral pain during a single=limb squat than in females without patellofemoral pain, and decrease in females with patellofemoral pain following instruction. Study Design: Controlled Laboratory Study. Data were captured while participants performed single limb squats under two conditions: usual and corrected. Two=dimensional hip and knee angles and a DVI that combined the hip and knee angles were calculated. Three=dimensional sagittal, frontal, and transverse plane angles of the hip and knee and a DVI combining the frontal and transverse plane angles were calculated. The two=dimensional DVI demonstrated moderate reliability (ICC=0.74). The correlation between the two=dimensional and three=dimensional DVI's was 0.635 (ppatellofemoral pain demonstrated a greater two=dimensional DVI (31.14 °±13.36 °) than females without patellofemoral pain (18.30 °±14.97 °; p=0.010). Females with patellofemoral pain demonstrated a decreased DVI in the corrected (19.04 °±13.70 °) versus usual (31.14 °±13.36 °) condition (p=0.001). The DVI is a reliable and valid measure that may provide a more comprehensive assessment of lower=extremity movement patterns than the knee frontal plane projection angle in individuals with lower=extremity musculoskeletal pain problems. 2b.

  2. Soft tissue artifact compensation in knee kinematics by multi-body optimization: Performance of subject-specific knee joint models.

    Science.gov (United States)

    Clément, Julien; Dumas, Raphaël; Hagemeister, Nicola; de Guise, Jaques A

    2015-11-05

    Soft tissue artifact (STA) distort marker-based knee kinematics measures and make them difficult to use in clinical practice. None of the current methods designed to compensate for STA is suitable, but multi-body optimization (MBO) has demonstrated encouraging results and can be improved. The goal of this study was to develop and validate the performance of knee joint models, with anatomical and subject-specific kinematic constraints, used in MBO to reduce STA errors. Twenty subjects were recruited: 10 healthy and 10 osteoarthritis (OA) subjects. Subject-specific knee joint models were evaluated by comparing dynamic knee kinematics recorded by a motion capture system (KneeKG™) and optimized with MBO to quasi-static knee kinematics measured by a low-dose, upright, biplanar radiographic imaging system (EOS(®)). Errors due to STA ranged from 1.6° to 22.4° for knee rotations and from 0.8 mm to 14.9 mm for knee displacements in healthy and OA subjects. Subject-specific knee joint models were most effective in compensating for STA in terms of abduction-adduction, inter-external rotation and antero-posterior displacement. Root mean square errors with subject-specific knee joint models ranged from 2.2±1.2° to 6.0±3.9° for knee rotations and from 2.4±1.1 mm to 4.3±2.4 mm for knee displacements in healthy and OA subjects, respectively. Our study shows that MBO can be improved with subject-specific knee joint models, and that the quality of the motion capture calibration is critical. Future investigations should focus on more refined knee joint models to reproduce specific OA knee geometry and physiology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. KNEE ISOKINETIC TORQUE IMBALANCE IN FEMALE FUTSAL PLAYERS

    Directory of Open Access Journals (Sweden)

    Ana Carolina de Mello Alves Rodrigues

    Full Text Available ABSTRACT Introduction: The specificity of sports training can lead to muscle specialization with a possible change in the natural hamstring/quadriceps torque ratio (HQ ratio, constituting a risk factor for muscle injury at the joint angles in which muscle imbalance may impair dynamic stability. Objective: The aim was to evaluate the torque distribution of the hamstrings and quadriceps and the HQ ratio throughout the range of motion in order to identify possible muscle imbalances at the knee of female futsal athletes. Methods: Nineteen amateur female futsal athletes had their dominant limb HQ ratio evaluated in a series of five maximum repetitions of flexion/extension of the knee at 180°/second in the total joint range of motion (30° to 80°. The peak flexor and extensor torque and the HQ ratio (% were compared each 5° of knee motion using one-way repeated measures ANOVA and Tukey’s post hoc test (p<0.05 to determine the joint angles that present muscular imbalance. Results: Quadriceps torque was higher than 50° to 60° of knee flexion, while hamstrings torque was higher than 55° to 65°. The HQ ratio presented lower values than 30° to 45° of knee flexion and four athletes presented values lower than 60%, which may represent a risk of injury. However, the HQ ratio calculated by the peak torque showed only one athlete with less than 60%. Conclusion: The HQ ratio analyzed throughout the knee range of motion allowed identifying muscle imbalance at specific joint angles in female futsal players.

  4. Prevention and management of knee osteoarthritis and knee cartilage injury in sports.

    Science.gov (United States)

    Takeda, Hideki; Nakagawa, Takumi; Nakamura, Kozo; Engebretsen, Lars

    2011-04-01

    Articular cartilage defects in the knee of young or active individuals remain a problem in orthopaedic practice. These defects have limited ability to heal and may progress to osteoarthritis. The prevalence of knee osteoarthritis among athletes is higher than in the non-athletic population. The clinical symptoms of osteoarthritis are joint pain, limitation of range of motion and joint stiffness. The diagnosis of osteoarthritis is confirmed by the symptoms and the radiological findings (narrowing joint space, osteophyte formation and subchondral sclerosis). There is no strong correlation between symptoms and radiographic findings. The aetiology of knee osteoarthritis is multifactorial. Excessive musculoskeletal loading (at work or in sports), high body mass index, previous knee injury, female gender and muscle weakness are well-known risk factors. The high-level athlete with a major knee injury has a high incidence of knee osteoarthritis. Cartilage injuries are frequently observed in young and middle-aged active athletes. Often this injury precedes osteoarthritis. Reducing risk factors can decrease the prevalence of knee osteoarthritis. The prevention of knee injury, especially anterior cruciate ligament and meniscus injury in sports, is important to avoid progression of knee osteoarthritis.

  5. Validity and reliability of using photography for measuring knee range of motion: a methodological study

    Directory of Open Access Journals (Sweden)

    Adie Sam

    2011-04-01

    Full Text Available Abstract Background The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measuring knee range of motion using goniometry and photographic records. Methods Design: Methodology study assessing the validity and reliability of one method ('Marker Method' which uses a skin marker over the greater trochanter and another method ('Line of Femur Method' which requires estimation of the line of femur. Setting: Radiology and orthopaedic departments of two teaching hospitals. Participants: 31 volunteers (13 arthritic and 18 healthy subjects. Knee range of motion was measured radiographically and photographically using a goniometer. Three assessors were assessed for reliability and validity. Main outcomes: Agreement between methods and within raters was assessed using concordance correlation coefficient (CCCs. Agreement between raters was assessed using intra-class correlation coefficients (ICCs. 95% limits of agreement for the mean difference for all paired comparisons were computed. Results Validity (referenced to radiographs: Each method for all 3 raters yielded very high CCCs for flexion (0.975 to 0.988, and moderate to substantial CCCs for extension angles (0.478 to 0.678. The mean differences and 95% limits of agreement were narrower for flexion than they were for extension. Intra-rater reliability: For flexion and extension, very high CCCs were attained for all 3 raters for both methods with slightly greater CCCs seen for flexion (CCCs varied from 0.981 to 0.998. Inter-rater reliability: For both methods, very high ICCs (min to max: 0.891 to 0.995 were obtained for flexion and extension. Slightly higher coefficients were obtained

  6. Modelling knee flexion effects on joint power absorption and adduction moment.

    Science.gov (United States)

    Nagano, Hanatsu; Tatsumi, Ichiroh; Sarashina, Eri; Sparrow, W A; Begg, Rezaul K

    2015-12-01

    Knee osteoarthritis is commonly associated with ageing and long-term walking. In this study the effects of flexing motions on knee kinetics during stance were simulated. Extended knees do not facilitate efficient loading. It was therefore, hypothesised that knee flexion would promote power absorption and negative work, while possibly reducing knee adduction moment. Three-dimensional (3D) position and ground reaction forces were collected from the right lower limb stance phase of one healthy young male subject. 3D position was sampled at 100 Hz using three Optotrak Certus (Northern Digital Inc.) motion analysis camera units, set up around an eight metre walkway. Force plates (AMTI) recorded ground reaction forces for inverse dynamics calculations. The Visual 3D (C-motion) 'Landmark' function was used to change knee joint positions to simulate three knee flexion angles during static standing. Effects of the flexion angles on joint kinetics during the stance phase were then modelled. The static modelling showed that each 2.7° increment in knee flexion angle produced 2.74°-2.76° increments in knee flexion during stance. Increased peak extension moment was 6.61 Nm per 2.7° of increased knee flexion. Knee flexion enhanced peak power absorption and negative work, while decreasing adduction moment. Excessive knee extension impairs quadriceps' power absorption and reduces eccentric muscle activity, potentially leading to knee osteoarthritis. A more flexed knee is accompanied by reduced adduction moment. Research is required to determine the optimum knee flexion to prevent further damage to knee-joint structures affected by osteoarthritis. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. MRI assessment of knee osteoarthritis: Knee Osteoarthritis Scoring System (KOSS) - inter-observer and intra-observer reproducibility of a compartment-based scoring system

    International Nuclear Information System (INIS)

    Kornaat, Peter R.; Ceulemans, Ruth Y.T.; Kroon, Herman M.; Bloem, Johan L.; Riyazi, Naghmeh; Kloppenburg, Margreet; Carter, Wayne O.; Woodworth, Thasia G.

    2005-01-01

    To develop a scoring system for quantifying osteoarthritic changes of the knee as identified by magnetic resonance (MR) imaging, and to determine its inter- and intra-observer reproducibility, in order to monitor medical therapy in research studies. Two independent observers evaluated 25 consecutive MR examinations of the knee in patients with previously defined clinical symptoms and radiological signs of osteoarthritis. We acquired on a 1.5 T system: coronal and sagittal proton density- and T2-weighted dual spin echo (SE) images, sagittal three-dimensional T1-weighted gradient echo (GE) images with fat suppression, and axial dual turbo SE images with fat suppression. Images were scored for the presence of cartilaginous lesions, osteophytes, subchondral cysts, bone marrow edema, and for meniscal abnormalities. Presence and size of effusion, synovitis and Baker's cyst were recorded. All parameters were ranked on a previously defined, semiquantitative scale, reflecting increasing severity of findings. Kappa, weighted kappa and intraclass correlation coefficient (ICC) were used to determine inter- and intra-observer variability. Inter-observer reproducibility was good (ICC value 0.77). Inter- and intra-observer reproducibility for individual parameters was good to very good (inter-observer ICC value 0.63-0.91; intra-observer ICC value 0.76-0.96). The presented comprehensive MR scoring system for osteoarthritic changes of the knee has a good to very good inter-observer and intra-observer reproducibility. Thus the score form with its definitions can be used for standardized assessment of osteoarthritic changes to monitor medical therapy in research studies. (orig.)

  8. Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

    Directory of Open Access Journals (Sweden)

    Karade Vikas

    2012-10-01

    Full Text Available Abstract Background In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. Methods A comparative study of the accuracy of extramedullary and intramedullary tibial cutting guides was carried out in 92 megaprosthetic knee replacements for distal femoral tumors. For the proximal tibia cut for tibial component placement, an extramedullary guide was used in 65 patients and an intramedullary guide was used in 27 patients. Tibial component alignment angles were measured in postoperative X-rays with the help of CAD software. Results There was more varus placement in coronal plane with extramedullary cutting guide (−1.18 +/− 2.4 degrees than the intramedullary guide (−0.34 +/− 2.31 degrees but this did not reach statistical significance. The goal of 90 +/− 2 degrees alignment of tibial component was achieved in 54% of patients in the extramedullary group versus 67% in the intramedullary group. In terms of sagittal plane alignment, extramedullary guide showed less accurate results (2.09 +/− 2.4 degrees than intramedullary guide (0.50 +/− 3.80 degrees for tibial component alignment, though 78% of patients were aligned within the goal of 0–5 degrees of tibial slope angle in extramedullary group versus 63% in intramedullary group. The mean error in the measurements due to rotation of the knee during taking the X-rays was less than 0.1 degrees and distribution of the X-rays with the rotation of knee was similar in both the groups. Conclusions Overall, in megaprosthetic knee replacement intramedullary guides gave more accurate results in sagittal plane and exhibited similar variability as of extramedullary guides in coronal plane.

  9. Examining Ankle-Joint Laxity Using 2 Knee Positions and With Simulated Muscle Guarding.

    Science.gov (United States)

    Hanlon, Shawn; Caccese, Jaclyn; Knight, Christopher A; Swanik, Charles Buz; Kaminski, Thomas W

    2016-02-01

    Several factors affect the reliability of the anterior drawer and talar tilt tests, including the individual clinician's experience and skill, ankle and knee positioning, and muscle guarding. To compare gastrocnemius activity during the measurement of ankle-complex motion at different knee positions, and secondarily, to compare ankle-complex motion during a simulated trial of muscle guarding. Cross-sectional study. Research laboratory. Thirty-three participants aged 20.2 ± 1.7 years were tested. The ankle was loaded under 2 test conditions (relaxed, simulated muscle guarding) at 2 knee positions (0°, 90° of flexion) while gastrocnemius electromyography (EMG) activity was recorded. Anterior displacement (mm), inversion-eversion motion (°), and peak EMG amplitude values of the gastrocnemius (μV). Anterior displacement did not differ between the positions of 0° and 90° of knee flexion (P = .193). Inversion-eversion motion was greater at 0° of knee flexion compared with 90° (P ankle laxity at the 2 most common knee positions for anterior drawer testing; however, talar tilt testing may be best performed with the knee in 0° of knee flexion. Finally, our outcomes from the simulated muscle-guarding condition suggest that clinicians should use caution and be aware of reduced perceived laxity when performing these clinical examination techniques immediately postinjury.

  10. The influence of knee alignment on lower extremity kinetics during squats.

    Science.gov (United States)

    Slater, Lindsay V; Hart, Joseph M

    2016-12-01

    The squat is an assessment of lower extremity alignment during movement, however there is little information regarding altered joint kinetics during poorly performed squats. The purpose of this study was to examine changes in joint kinetics and power from altered knee alignment during a squat. Thirty participants completed squats while displacing the knee medially, anteriorly, and with neutral alignment (control). Sagittal and frontal plane torques at the ankle, knee, and hip were altered in the descending and ascending phase of the squat in both the medial and anterior malaligned squat compared to the control squat. Ankle and trunk power increased and hip power decreased in the medial malaligned squat compared to the control squat. Ankle, knee, and trunk power increased and hip power decreased in the anterior malaligned squat compared to the control squat. Changes in joint torques and power during malaligned squats suggest that altered knee alignment increases ankle and trunk involvement to execute the movement. Increased anterior knee excursion during squatting may also lead to persistent altered loading of the ankle and knee. Sports medicine professionals using the squat for quadriceps strengthening must consider knee alignment to reduce ankle and trunk involvement during the movement. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Quadriceps strength and anterior knee pain following tibia ...

    African Journals Online (AJOL)

    The tension generated on extension of the knee against a resistance using tensiometer was measured in Newton. The ranges of motion of the knees were documented, as well as Lysholm score which measures activities and document the presence and limitation caused by anterior knee pain. Results: A total of 36 patients ...

  12. Sagittal alignment after single cervical disc arthroplasty.

    Science.gov (United States)

    Guérin, Patrick; Obeid, Ibrahim; Gille, Olivier; Bourghli, Anouar; Luc, Stéphane; Pointillart, Vincent; Vital, Jean-Marc

    2012-02-01

    Prospective study. To analyze the sagittal balance after single-level cervical disc replacement (CDR) and range of motion (ROM). To define clinical and radiologic parameters those have a significant correlation with segmental and overall cervical curvature after CDR. Clinical outcomes and ROM after CDR with Mobi-C (LDR, Troyes, France) prosthesis have been documented in few studies. No earlier report of this prosthesis has studied correlations between static and dynamic parameters or those between static parameters and clinical outcomes. Forty patients were evaluated. Clinical outcome was assessed using the Short Form-36 questionnaire, Neck Disability Index, and a Visual Analog Scale. Spineview software (Surgiview, Paris, France) was used to investigate sagittal balance parameters and ROM. The mean follow-up was 24.3 months (range: 12 to 36 mo). Clinical outcomes were satisfactory. There was a significant improvement of Short Form-36, Neck Disability Index, and Visual Analog Scale scores. Mean ROM was 8.3 degrees preoperatively and 11.0 degrees postoperatively (P=0.013). Mean preoperative C2C7 curvature was 12.8 and 16.0 degrees at last follow-up (P=0.001). Mean preoperative functional spinal unit (FSU) angle was 2.3 and 5.3 degrees postoperatively (P<0.0001). Mean postoperative shell angle was 5.5 degrees. There was a significant correlation between postoperative C2C7 alignment and preoperative C2C7 alignment, change of C2C7 alignment, preoperative and postoperative FSU angle, and prosthesis shell angle. There was also a significant correlation between postoperative FSU angle and preoperative C2C7 alignment, preoperative FSU angle, change of FSU angle, and prosthesis shell angle. Regression analysis showed that prosthesis shell angle and preoperative FSU angle contributed significantly to postoperative FSU angle. Moreover, preoperative C2C7 alignment, preoperative FSU angle, postoperative FSU angle, and prosthesis shell angle contributed significantly to

  13. Fast three-dimensional MR imaging of the knee: A comparison with arthroscopy

    International Nuclear Information System (INIS)

    Tyrrell, R.; Gluckert, K.; Yulish, B.; Pathria, M.N.; Goodfellow, D.

    1987-01-01

    Fifty patients with suspected knee pathology were evaluated with fast volume imaging and compared to arthroscopy as a gold standard. The knee was imaged with FISP (repetition time 28 msec/echo time, 14 msec/flip angle, 40 degrees) in a sagittal plane generating 64 continguous slices in about 8 minutes. A numerical grading system that could be used for both MR and arthroscopy was devised. Results showed that there was a 95% agreement between MR and arthroscopy in meniscal tears; 100% correlation between MR and severely degenerated menisci; 100% agreement of partial cruciate tears; and high correlation for high-grade cartilage lesions

  14. The use of parallel imaging for MRI assessment of knees in children and adolescents.

    Science.gov (United States)

    Doria, Andrea S; Chaudry, Gulraiz A; Nasui, Cristina; Rayner, Tammy; Wang, Chenghua; Moineddin, Rahim; Babyn, Paul S; White, Larry M; Sussman, Marshall S

    2010-03-01

    Parallel imaging provides faster scanning at the cost of reduced signal-to-noise ratio (SNR) and increased artifacts. To compare the diagnostic performance of two parallel MRI protocols (PPs) for assessment of pathologic knees using an 8-channel knee coil (reference standard, conventional protocol [CP]) and to characterize the SNR losses associated with parallel imaging. Two radiologists blindly interpreted 1.5 Tesla knee MRI images in 21 children (mean 13 years, range 9-18 years) with clinical indications for an MRI scan. Sagittal proton density, T2-W fat-saturated FSE, axial T2-W fat-saturated FSE, and coronal T1-W (NEX of 1,1,1) images were obtained with both CP and PP. Images were read for soft tissue and osteochondral findings. There was a 75% decrease in acquisition time using PP in comparison to CP. The CP and PP protocols fell within excellent or upper limits of substantial agreement: CP, kappa coefficient, 0.81 (95% CIs, 0.73-0.89); PP, 0.80-0.81 (0.73-0.89). The sensitivity of the two PPs was similar for assessment of soft (0.98-1.00) and osteochondral (0.89-0.94) tissues. Phantom data indicated an SNR of 1.67, 1.6, and 1.51 (axial, sagittal and coronal planes) between CP and PP scans. Parallel MRI provides a reliable assessment for pediatric knees in a significantly reduced scan time without affecting the diagnostic performance of MRI.

  15. Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee

    LENUS (Irish Health Repository)

    Cashman, James P

    2011-08-20

    Abstract Background Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. Method A comparison of intramedullary versus extramedullary alignment jig was performed. Radiological alignment of tibial components and patient outcomes of 103 Triathlon total knee arthroplasties were analysed. Results Use of the intramedullary was found to be significantly more accurate in determining coronal alignment (p = 0.02) while use of the extramedullary jig was found to give more accurate results in sagittal alignment (p = 0.04). There was no significant difference in WOMAC or SF-36 at six months. Conclusion Use of an intramedullary jig is preferable for positioning of the tibial component using this knee system.

  16. Comprehensive profile of hip, knee and ankle ranges of motion in professional football players.

    Science.gov (United States)

    López-Valenciano, Alejandro; Ayala, Francisco; Vera-García, Francisco J; de Ste Croix, Mark; Hernández-Sánchez, Sergio; Ruiz-Pérez, Iñaki; Cejudo, Antonio; Santonja, Fernando

    2017-10-31

    Limited ranges of motion (ROM) have been considered as a primary risk factor for some football injuries, but only a few studies have analysed differences in lower extremity joints. The main purposes were (a) to describe the lower extremity ROM profile in professional football players; and (b) to examine differences between goalkeepers and outfield players. 82 professional male football players from 4 teams were measured in the 2013 pre-season. Measures of passive hip (flexion with knee flexed [PHFKF] and extended [PHFKE], extension [PHE], abduction [PHA], external [PHER] and internal [PHIR] rotation), knee (flexion [PKF]) and ankle (dorsiflexion with knee flexed [ADFKF] and extended [ADFKE]) ROMs were taken. Magnitude-based inferences exploring differences between player position and limb were made. 46% of all participants showed restricted PHFKE and/or around 30% showed restricted ADFKF ROM values. Contrarily, most players reported normal PHFKF, PHE, PHIR and PHER as well as PKF ROM scores with percentage values close to 100%. Bilateral meaningful differences for PHA, PHIR and PHER were found in approximately 30% of outfield players and goalkeepers. Statistical analysis found trivial differences between players for PHFKE, PHE, PHIR, PHER, ADFKE and ADFKF. However, moderate differences between players were found for PHFKF, PHA and PKF, with goalkeepers demonstrating higher values than outfield players. The findings of this study reinforce the necessity of prescribing exercises aimed at improving PHFKE and ADFKF ROM within everyday football training routines. In addition, as some bilateral deficits were observed, unilateral training should be considered where appropriate.

  17. Retrospective Evaluation Of MRI Findings Of Knee Joint In 255 Patients

    Directory of Open Access Journals (Sweden)

    Ahmet Mete

    2003-03-01

    Full Text Available Retrospective evaluation of knee MRI obtained from 255 cases and to demonstrate most common knee joint pathologies in our region.In our study knee joints of 255 cases who admitted to different clinics of our hospital with various complains of knee between October 1996 and December 1998 were examined in wide spectrum with MRI. Via 1.0 Tesla MRI device and special knee coil in sagittal, coronal and axial plains MRI images were obtained. The number of male and female patients were 173 and 82 and their ages were ranged between 14 and 70, and the mean age was 3413.The most common knee pathologies were intra-articular fluid (%58.04, medial (%46,66 and lateral (%12.55 meniscal injuries, anterior cruciate ligament injury (%17.25 and osteoarthritis (%14.9. The other important lesions were degeneration of medial and lateral meniscus, Baker’s cyst, bursitis, posterior cruciate ligament injury , medial and lateral collateral ligament injuries, synovial hypertrophy, chondromalasia of patella, and contusion.In our images of knee the most common lesions were injuries of meniscus and ligament. Because of being noninvasive technique for knee joint pathologies, capacity of multiplanar imaging, high contrast resolution and chance of detailed anatomic evaluation MR imaging was found to be most appropriate imaging technique for knee joint pathologies.

  18. Cervical spine motion: radiographic study

    International Nuclear Information System (INIS)

    Morgan, J.P.; Miyabayashi, T.; Choy, S.

    1986-01-01

    Knowledge of the acceptable range of motion of the cervical spine of the dog is used in the radiographic diagnosis of both developmental and degenerative diseases. A series of radiographs of mature Beagle dogs was used to identify motion within sagittal and transverse planes. Positioning of the dog's head and neck was standardized, using a restraining board, and mimicked those thought to be of value in diagnostic radiology. The range of motion was greatest between C2 and C5. Reports of severe disk degeneration in the cervical spine of the Beagle describe the most severely involved disks to be C4 through C7. Thus, a high range of motion between vertebral segments does not seem to be the cause for the severe degenerative disk disease. Dorsoventral slippage between vertebral segments was seen, but was not accurately measured. Wedging of disks was clearly identified. At the atlantoaxio-occipital region, there was a high degree of motion within the sagittal plane at the atlantoaxial and atlanto-occipital joints; the measurement can be a guideline in the radiographic diagnosis of instability due to developmental anomalies in this region. Lateral motion within the transverse plane was detected at the 2 joints; however, motion was minimal, and the measurements seemed to be less accurate because of rotation of the cervical spine. Height of the vertebral canal was consistently noted to be greater at the caudal orifice, giving some warning to the possibility of overdiagnosis in suspected instances of cervical spondylopathy

  19. Magnetic resonance imaging reflects cartilage proteoglycan degradation in the rabbit knee

    International Nuclear Information System (INIS)

    Paul, P.K.; O'Byrne, E.; Blancuzzi, V.; Wilson, D.; Gunson, D.; Douglas, F.L.; Wang Jinzhao; Mezrich, R.S.

    1991-01-01

    Cartilage degeneration in osteoarthritis is initiated by a loss of proteoglycan. Intra-articular injection of papain causes a reversible loss of proteoglycan in rabbit knees. Rabbits were scanned with magnetic resonance imaging (MRI), using a 1.5T Signa superconducting magnet with 3 inch surface coil. Spin echo sequences were performed in the coronal and sagittal planes at 0, 24, 48, and 72 h after intra-articular injection of papain to abtain T 1 , proton density, and T 2 -weighted images. Cartilage proteoglycan content was measured biochemically and histochemically. Reduced articular cartilage thickness in the MR images of papain-treated knees corresponded to changes in cartilage proteoglycan content. (orig.)

  20. Medium-term evaluation of total knee arthroplasty without patellar replacement

    Directory of Open Access Journals (Sweden)

    José Wanderley Vasconcelos

    2013-06-01

    Full Text Available OBJECTIVE: To mid-term evaluate patients who were submitted to total knee arthroplasty without patellar resurfacing. METHODS: It was realized a retrospective cross-sectional study of patients who were submitted to total knee arthroplasty without patellar resurfacing. In all patients clinical examination was done based on the protocol of the Knee Society Scoring System, which assessed pain, range of motion, stability, contraction, knee alignment and function, and radiological evaluation. RESULTS: A total of 36 patients were evaluated. Of these, 07 were operated only on left knee, 12 only on right knee and 17 were operated bilaterally, totaling 53 knees. Ages ranged from 26 to 84 years. Of the 53 knees evaluated, 33 (62.26% had no pain. The maximum flexion range of motion averaged 104.7°. No knee had difficulty in active extension. As to the alignment for anatomical axis twelve knees (22.64% showed deviation between 0° and 4° varus. Thirty-nine (75.49% knees showed pace without restriction and the femorotibial angle ranged between 3° varus and 13° valgus with an average of 5° valgus. The patellar index ranged from 0.2 to 1.1. CONCLUSION: Total knee arthroplasty whitout patellar resurfacing provides good results in mid-term evaluation.

  1. Associations between lower extremity muscle mass and multiplanar knee laxity and stiffness: a potential explanation for sex differences in frontal and transverse plane knee laxity.

    Science.gov (United States)

    Shultz, Sandra J; Pye, Michele L; Montgomery, Melissa M; Schmitz, Randy J

    2012-12-01

    Compared with men, women have disproportionally greater frontal (varus-valgus) and transverse (internal-external) plane laxity and lower stiffness, despite having similar sagittal (anterior-posterior) plane laxity and stiffness. While the underlying cause is unclear, the amount of lower extremity lean mass (LELM) may be a contributing factor. Lower extremity lean mass would be a stronger predictor of frontal and transverse plane laxity and incremental stiffness than the sagittal plane. Associations between LELM and stiffness would be stronger at lower force increments. Descriptive laboratory study. Sixty-three women and 30 men with no history of ligament injury were measured for knee laxity and incremental stiffness in the sagittal (-90- to 130-N posterior-to-anterior directed loads), frontal (±10-N·m varus-valgus torques), and transverse (±5-N·m internal-external rotation torques) planes and underwent dual-energy X-ray absorptiometry scans to measure LELM. Linear regressions examined the extent to which LELM predicted each laxity and stiffness value, while also accounting for a person's sex. Females (vs males) had greater laxity and less stiffness in the frontal and transverse planes but not the sagittal plane. Lower extremity lean mass was a poor predictor of sagittal laxity and stiffness (R (2) range = .021-.081; P > .06) but was a stronger predictor of frontal (R (2) range = .215-.567; P plane laxity and stiffness. Associations were stronger for low (R (2) = .495-.504) versus high (R (2) = .215-.435) frontal plane stiffness but were similar for low (R (2) = .233-.293) versus high (R (2) = .224-.356) transverse plane stiffness. Once we accounted for a person's LELM, sex had little effect on laxity and stiffness (change in R (2) after removal = .01-.08; P = .027-.797). Less LELM was associated with greater laxity and less stiffness in frontal and transverse planes, which may contribute to the disproportionally higher laxities and reduced stiffnesses observed

  2. The Nature of Age-Related Differences in Knee Function during Walking: Implication for the Development of Knee Osteoarthritis.

    Directory of Open Access Journals (Sweden)

    Katherine A Boyer

    Full Text Available Changes in knee kinematics have been identified in the early stages of osteoarthritis (OA. However, there is a paucity of information on the nature of kinematic change that occur with aging prior to the development of OA, This study applied a robust statistical method (Principal Component Analysis to test the hypothesis that coupling between primary (flexion and secondary (anterior-posterior translation, internal-external rotation joint motions in walking would differ for age groupings of healthy subjects.Seventy-four healthy participants divided into three groups with mean ages of 24 ± 2.3 years (younger, 48 ± 4.7years (middle-age and 64 ± 2.4 years (older were examined. Principal Component Analysis was used to characterize and statistically compare the patterns of knee joint movement and their relationships in walking.There were significant differences between the younger group and both the middle-age and older groups in the knee frontal plane angle and the coupling between knee flexion (PC1, p≤0.04 and the relative magnitudes of secondary plane motions in early and late stance (PC3, p<0.01. Two additional principal components (PC2, p = 0.03 and PC5, p<0.01 described differences in early stance knee flexion and relationship with secondary plane motion through-out stance for the older compared with middle-age group.It appears there are changes in knee kinematics that occur with aging. The kinematic differences were identified for middle-aged as well as older adults suggesting midlife changes in neuromuscular physiology or behavior may have important consequences. These kinematic measures offer the potential to identify early markers for the risk of developing knee OA with aging.

  3. Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment

    International Nuclear Information System (INIS)

    Choi, Jang-Hwan; Maier, Andreas; Keil, Andreas; McWalter, Emily J.; Gold, Garry E.; Fahrig, Rebecca; Pal, Saikat; Beaupré, Gary S.

    2014-01-01

    Purpose: A C-arm CT system has been shown to be capable of scanning a single cadaver leg under loaded conditions by virtue of its highly flexible acquisition trajectories. In Part I of this study, using the 4D XCAT-based numerical simulation, the authors predicted that the involuntary motion in the lower body of subjects in weight-bearing positions would seriously degrade image quality and the authors suggested three motion compensation methods by which the reconstructions could be corrected to provide diagnostic image quality. Here, the authors demonstrate that a flat-panel angiography system is appropriate for scanning both legs of subjectsin vivo under weight-bearing conditions and further evaluate the three motion-correction algorithms using in vivo data. Methods: The geometry of a C-arm CT system for a horizontal scan trajectory was calibrated using the PDS-2 phantom. The authors acquired images of two healthy volunteers while lying supine on a table, standing, and squatting at several knee flexion angles. In order to identify the involuntary motion of the lower body, nine 1-mm-diameter tantalum fiducial markers were attached around the knee. The static mean marker position in 3D, a reference for motion compensation, was estimated by back-projecting detected markers in multiple projections using calibrated projection matrices and identifying the intersection points in 3D of the back-projected rays. Motion was corrected using three different methods (described in detail previously): (1) 2D projection shifting, (2) 2D deformable projection warping, and (3) 3D rigid body warping. For quantitative image quality analysis, SSIM indices for the three methods were compared using the supine data as a ground truth. Results: A 2D Euclidean distance-based metric of subjects’ motion ranged from 0.85 mm (±0.49 mm) to 3.82 mm (±2.91 mm) (corresponding to 2.76 to 12.41 pixels) resulting in severe motion artifacts in 3D reconstructions. Shifting in 2D, 2D warping, and 3D

  4. Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions

    International Nuclear Information System (INIS)

    Li, X.; Yu, C.; Wu, H.; Daniel, K.; Hu, D.; Xia, L.; Pan, C.; Xu, A.; Hu, J.; Wang, L.; Peng, W.; Li, F.

    2009-01-01

    Aim: To prospectively compare the accuracy of three-dimensional fast imaging employing steady-state acquisition (3D FIESTA) sequences with that of fat-suppressed three-dimensional spoiled gradient-recalled (3D SPGR) in the diagnosis of knee articular cartilage lesions, using arthroscopy as the reference standard. Materials and methods: Fifty-eight knees in 54 patients (age range 21-82 years; mean 36 years) were prospectively evaluated by using sagittal 3D FIESTA and sagittal fat-suppressed 3D SPGR sequences. Articular cartilage lesions were graded on MRI and during arthroscopy with a modified Noyes scoring system. Sensitivity, specificity, and accuracy were assessed. Interobserver agreement was determined with κ statistics. Results: The performance of 3D FIESTA sequences (sensitivity, specificity, and accuracy were 80, 94, and 92%, respectively, for reader 1 and 76, 94, and 90%, respectively, for reader 2) was similar to that of fat-suppressed 3D SPGR sequences (sensitivity, specificity, and accuracy were 82, 92, and 90%, respectively, for reader 1 and 82, 90, and 88%, respectively, for reader 2) in the detection of knee articular cartilage lesions. The interobserver agreement varied from fair to good to excellent (kappa values from 0.43-0.83). Conclusion: 3D FIESTA has good diagnostic performance, comparable with fat-suppressed 3D SPGR in evaluating knee cartilage lesions, and it can be incorporated into routine knee MRI protocols due to the short acquisition time.

  5. Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions

    Energy Technology Data Exchange (ETDEWEB)

    Li, X.; Yu, C. [Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China); Wu, H. [Department of Orthopaedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China)], E-mail: lilyboston2002@163.com; Daniel, K. [Department of Radiology, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA 02115 (United States); Hu, D.; Xia, L.; Pan, C.; Xu, A.; Hu, J.; Wang, L.; Peng, W. [Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China); Li, F. [Department of Orthopaedics, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030 (China)

    2009-10-15

    Aim: To prospectively compare the accuracy of three-dimensional fast imaging employing steady-state acquisition (3D FIESTA) sequences with that of fat-suppressed three-dimensional spoiled gradient-recalled (3D SPGR) in the diagnosis of knee articular cartilage lesions, using arthroscopy as the reference standard. Materials and methods: Fifty-eight knees in 54 patients (age range 21-82 years; mean 36 years) were prospectively evaluated by using sagittal 3D FIESTA and sagittal fat-suppressed 3D SPGR sequences. Articular cartilage lesions were graded on MRI and during arthroscopy with a modified Noyes scoring system. Sensitivity, specificity, and accuracy were assessed. Interobserver agreement was determined with {kappa} statistics. Results: The performance of 3D FIESTA sequences (sensitivity, specificity, and accuracy were 80, 94, and 92%, respectively, for reader 1 and 76, 94, and 90%, respectively, for reader 2) was similar to that of fat-suppressed 3D SPGR sequences (sensitivity, specificity, and accuracy were 82, 92, and 90%, respectively, for reader 1 and 82, 90, and 88%, respectively, for reader 2) in the detection of knee articular cartilage lesions. The interobserver agreement varied from fair to good to excellent (kappa values from 0.43-0.83). Conclusion: 3D FIESTA has good diagnostic performance, comparable with fat-suppressed 3D SPGR in evaluating knee cartilage lesions, and it can be incorporated into routine knee MRI protocols due to the short acquisition time.

  6. Pathological Knee Joint Motion Analysis By High Speed Cinephotography

    Science.gov (United States)

    Baumann, Jurg U.

    1985-02-01

    The use of cinephotography for evaluation of disturbed knee joint function was compared in three groups of patients. While a sampling rate of 50 images per second was adequate for patients with neuromuscular disorders, a higher frequency of around 300 i.p.s. is necessary in osteoarthritis and ligamentous knee joint injuries, but the task of digitizing is prohibitive unless automated.

  7. Sagittal crest formation in great apes and gibbons.

    Science.gov (United States)

    Balolia, Katharine L; Soligo, Christophe; Wood, Bernard

    2017-06-01

    The frequency of sagittal crest expression and patterns of sagittal crest growth and development have been documented in hominoids, including some extinct hominin taxa, and the more frequent expression of the sagittal crest in males has been traditionally linked with the need for larger-bodied individuals to have enough attachment area for the temporalis muscle. In the present study, we investigate sagittal cresting in a dentally mature sample of four hominoid taxa (Pan troglodytes schweinfurthii, Gorilla gorilla gorilla, Pongo pygmaeus pygmaeus and Hylobates lar). We investigate whether sagittal crest size increases with age beyond dental maturity in males and females of G. g. gorilla and Po. pyg. pygmaeus, and whether these taxa show sex differences in the timing of sagittal crest development. We evaluate the hypothesis that the larger sagittal crest of males may not be solely due to the requirement for a larger surface area than the un-crested cranial vault can provide for the attachment of the temporalis muscle, and present data on sex differences in temporalis muscle attachment area and sagittal crest size relative to cranial size. Gorilla g. gorilla and Po. pyg. pygmaeus males show significant relationships between tooth wear rank and sagittal crest size, and they show sagittal crest size differences between age groups that are not found in females. The sagittal crest emerges in early adulthood in the majority of G. g. gorilla males, whereas the percentage of G. g. gorilla females possessing a sagittal crest increases more gradually. Pongo pyg. pygmaeus males experience a three-fold increase in the number of specimens exhibiting a sagittal crest in mid-adulthood, consistent with a secondary growth spurt. Gorilla g. gorilla and Po. pyg. pygmaeus show significant sex differences in the size of the temporalis muscle attachment area, relative to cranial size, with males of both taxa showing positive allometry not shown in females. Gorilla g

  8. Can the Functional Movement Screen™ be used to capture changes in spine and knee motion control following 12 weeks of training?

    Science.gov (United States)

    Frost, David M; Beach, Tyson A C; Campbell, Troy L; Callaghan, Jack P; McGill, Stuart M

    2017-01-01

    To examine whether objective measures of spine and frontal plane knee motion exhibited during Functional Movement Screen™ (FMS) task performance changed following a movement-guided fitness (MOV) and conventional fitness (FIT) exercise intervention. Secondary analysis of a randomized controlled experiment. Before and after 12 weeks of exercise, participants' kinematics were quantified while performing the FMS and a series of general whole-body movement tasks. Biomechanics laboratory. Fifty-two firefighters were assigned to MOV, FIT, or a control (CON) group. Peak lumbar spine flexion/extension, lateral bend and axial twist, and frontal plane knee motion. The post-training kinematic changes exhibited by trainees while performing the FMS tasks were similar in magnitude (effect size  0.5). Whether graded qualitatively, or quantitatively via kinematic analyses, the FMS may not be a viable tool to detect movement-based exercise adaptations. Amendments to the FMS tasks and/or scoring method are needed before it can be used for reasons beyond appraising the ability to move freely, symmetrically, and without pain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Effects of Quadriceps Muscle Fatigue on Stiff-Knee Gait in Patients with Hemiparesis

    Science.gov (United States)

    Boudarham, Julien; Roche, Nicolas; Pradon, Didier; Delouf, Eric; Bensmail, Djamel; Zory, Raphael

    2014-01-01

    The relationship between neuromuscular fatigue and locomotion has never been investigated in hemiparetic patients despite the fact that, in the clinical context, patients report to be more spastic or stiffer after walking a long distance or after a rehabilitation session. The aim of this study was to evaluate the effects of quadriceps muscle fatigue on the biomechanical gait parameters of patients with a stiff-knee gait (SKG). Thirteen patients and eleven healthy controls performed one gait analysis before a protocol of isokinetic quadriceps fatigue and two after (immediately after and after 10 minutes of rest). Spatiotemporal parameters, sagittal knee and hip kinematics, rectus femoris (RF) and vastus lateralis (VL) kinematics and electromyographic (EMG) activity were analyzed. The results showed that quadriceps muscle weakness, produced by repetitive concentric contractions of the knee extensors, induced an improvement of spatiotemporal parameters for patients and healthy subjects. For the patient group, the increase in gait velocity and step length was associated with i) an increase of sagittal hip and knee flexion during the swing phase, ii) an increase of the maximal normalized length of the RF and VL and of the maximal VL lengthening velocity during the pre-swing and swing phases, and iii) a decrease in EMG activity of the RF muscle during the initial pre-swing phase and during the latter 2/3 of the initial swing phase. These results suggest that quadriceps fatigue did not alter the gait of patients with hemiparesis walking with a SKG and that neuromuscular fatigue may play the same functional role as an anti-spastic treatment such as botulinum toxin-A injection. Strength training of knee extensors, although commonly performed in rehabilitation, does not seem to be a priority to improve gait of these patients. PMID:24718087

  10. Knee extension and flexion: MR delineation of normal and torn anterior cruciate ligaments

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, Mamoru; Ikeda, Kotaroh; Fukubayashi, Tohru; Anno, Izumi; Itai, Yuji [Univ. of Tsukuba, Ibaraki (Japan)

    1996-03-01

    Our goal was to assess the effect of joint position of semiflexed and extended knees in MR delineation of the anterior cruciate ligament (ACL). With a mobile knee brace and a flexible surface coil, the knee joint was either fully extended or bent to a semiflexed position (average 45{degrees} of flexion) within the magnet bore. Sets of oblique sagittal MR images were obtained for both extended and flexed knee positions. Thirty-two knees with intact ACLs and 43 knees with arthroscopically proven ACL tears were evaluated. Two observers compared paired MR images of both extended and flexed positions and rated them by a relative three point scale. Anatomic correlation in MR images was obtained by a cadaveric knee with incremental flexion. The MR images of flexed knees were more useful than of extended knees in 53% of the case reviews of femoral attachments and 36% of reviews of midportions of normal ACLs. Compared with knee extensions, the MR images for knee flexion provided better clarity in 48% of reviews of disrupted sites and 52% of residual bundles of torn ACLs. Normal ACL appeared taut in the knee extension and lax in semiflexion. Compared with MR images of knees in extension, MR images of knees in flexion more clearly delineate the femoral side of the ligament with wider space under the intercondylar roof and with decreased volume-averaging artifacts, providing superior visualization of normal and torn ACLs. 13 refs., 7 figs., 1 tab.

  11. Influence of increasing knee flexion angle on knee-ankle varus stress during single-leg jump landing

    Directory of Open Access Journals (Sweden)

    Mariam A. Ameer, PhD

    2017-12-01

    Full Text Available Objectives: The primary aim of this study was to identify the relationship between the peak knee flexion angle and knee-ankle varus stress in the landing phase of the single-leg jump during running. Methods: Fifteen male handball players from the first Saudi Arabian handball team were incorporated in this study. Each player performed a single-leg jump-land after running a fixed distance of 450 cm. The data were measured using a 3D motion analysis system. The maximum knee flexion angle, knee varus angle, centre of pressure pathway in the medio-lateral direction, and ankle varus moment were measured. Results: The Pearson Product Moment Correlation showed that a greater knee flexion angle was related to a greater lateral displacement of the centre of pressure (r = 0.794, P = 0.000, a greater ankle varus moment (r = 0.707, P = 0.003, and a greater knee varus angle (r = 0.753, P = 0.001. In addition, the greater ankle varus moment was related to the greater lateral displacement of the centre of pressure (r = 0.734, P = 0.002. Conclusions: These findings may help physical therapists and conditioning professionals to understand the impact of increasing knee flexion angle on the lower limb joints. Such findings may help to develop training protocols for enhancing the lateral body reaction during the landing phase of the single-leg jump, which may protect the knee and ankle joints from excessive varus stresses. Keywords: 3D motion analysis, Ankle kinetic, Centre of pressure pathway, Handball playing, Knee kinematic, Single-leg jump

  12. Knee Flexion and Daily Activities in Patients following Total Knee Replacement: A Comparison with ISO Standard 14243

    Directory of Open Access Journals (Sweden)

    Markus A. Wimmer

    2015-01-01

    Full Text Available Walking is only one of many daily activities performed by patients following total knee replacement (TKR. The purpose of this study was to examine the hypotheses (a that subject activity characteristics are correlated with knee flexion range of motion (ROM and (b that there is a significant difference between the subject’s flexion/extension excursion throughout the day and the ISO specified input for knee wear testing. In order to characterize activity, the number of walking and stair stepping cycles, the time spent with dynamic and stationary activities, the number of activity sequences, and the knee flexion/extension excursion of 32 TKR subjects were collected during daily activity. Flexion/extension profiles were compared with the ISO 14243 simulator input profile using a level crossing classification algorithm. Subjects took an average of 3102 (range: 343–5857 walking cycles including 65 (range: 0–319 stair stepping cycles. Active and passive ROMs were positively correlated with stair walking time, stair step counts, and stair walking sequences. Simulated knee motion according to ISO showed significantly fewer level crossings at the flexion angles 20–40° and beyond 50° than those measured with the monitor. This suggests that implant wear testing protocols should contain more cycles and a variety of activities requiring higher knee flexion angles with incorporated resting/transition periods to account for the many activity sequences.

  13. Coupled motions in human and porcine thoracic and lumbar spines

    NARCIS (Netherlands)

    Kingma, Idsart; Busscher, Iris; van der Veen, Albert J.; Verkerke, Gijsbertus J.; Veldhuizen, Albert G.; Homminga, Jasper; van Dieën, Jaap H.

    2018-01-01

    Coupled motions, i.e., motions along axes other than the loaded axis, have been reported to occur in the human spine, and are likely to be influenced by inclined local axes due to the sagittal plane spine curvature. Furthermore, the role of facet joints in such motions is as yet unclear. Therefore,

  14. Coupled motions in human and porcine thoracic and lumbar spines

    NARCIS (Netherlands)

    Kingma, Idsart; Busscher, Iris; van der Veen, Albert J.; Verkerke, Gijsbertus J.; Veldhuizen, Albert G.; Homminga, Jasper; van Dieën, Jaap H.

    2017-01-01

    Coupled motions, i.e., motions along axes other than the loaded axis, have been reported to occur in the human spine, and are likely to be influenced by inclined local axes due to the sagittal plane spine curvature. Furthermore, the role of facet joints in such motions is as yet unclear. Therefore,

  15. Are the Kinematics of the Knee Joint Altered during the Loading Response Phase of Gait in Individuals with Concurrent Knee Osteoarthritis and Complaints of Joint Instability? A Dynamic Stereo X-ray Study

    Science.gov (United States)

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B.; Klatt, Brian A.; Fitzgerald, G. Kelley

    2011-01-01

    Background Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional declines in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Methods Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Findings Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (P knee joint at initial contact was significantly different (P knee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. Interpretations The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. PMID:22071429

  16. Increased Range of Motion Is Important for Functional Outcome and Satisfaction After Total Knee Arthroplasty in Asian Patients.

    Science.gov (United States)

    Ha, Chul-Won; Park, Yong-Beom; Song, Young-Suk; Kim, Jun-Ho; Park, Yong-Geun

    2016-06-01

    Although range of motion (ROM) is considered as an important factor for good outcome after total knee arthroplasty (TKA), the association of the degree of ROM with functional outcome and patient satisfaction is debated. We, therefore, investigated whether increased ROM would affect functional outcome and patient satisfaction after TKA in Asian patients. We reviewed 630 patients who underwent primary TKA with minimum 2-year follow-up. Clinical outcomes were evaluated by Knee Society (KS) score, Western Ontario and McMaster Universities osteoarthritis index, and high-flexion knee score. Patient satisfaction was evaluated using a validated questionnaire. The association of ROM and change in ROM (cROM) with clinical outcomes and satisfaction were analyzed using partial correlation analysis and multiple median regression analysis. All functional scores showed significant correlation with postoperative ROM (r = 0.129, P = .001 in Knee Society score; r = -0.101, P = .012 in Western Ontario and McMaster Universities osteoarthritis index; r = 0.183, P satisfaction (r = 0.192, P = .005). Postoperative ROM and cROM were revealed as predisposing factors affecting function outcome using multivariable regression analysis. cROM was found as a predisposing factor affecting satisfaction. Based on the results of this study, ROM positively associated with functional outcome and cROM positively associated with patient satisfaction after TKA. These findings suggest that increased ROM after TKA is an important factor for functional outcome and satisfaction in Asian patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. The MR diagnosis and clinical significance of bone contusion of knee

    International Nuclear Information System (INIS)

    Liu Wei; Yang Jun; Shao Kangwei; Zhu Caisong; Zhu Ying; Zhai Lulan

    2007-01-01

    Objective: To evaluate MRI in the diagnosis of the bone contusion of the knee .joint and its clinical significance. Methods: Using special coil for knee joint, coronal, sagittal, axial and oblique sagittal plane scanning with fast spin-echo sequence(T 1 WI, T 2 WI, PDWI + FS) was performed on knee joint in 205 patients in three days after injury. According the distributing bone marrow edema and injury mechanism, bone contusion were classified five types as pivot shift injury, clip injury, dashboard injury, hyperextension injury and lateral patellar dislocation. Results: One hundred and forty-five cases of the 205 patients were found bone marrow edema without fracture on X-ray films. Among them, pivot shift injury was found in 43 cases accompanied with anterior cruciate ligament rupture in 30 cases, tear of the posterior horn of the lateral or medial meniscus in 12 and tears of the medial collateral ligament in 8 cases; clip injury in 53 cases accompanied with anterior cruciate ligament rupture in 10 cases, tear of the posterior horn of the lateral or medial meniscus in 15 and tears of the medial collateral ligament in 38 cases; dashboard injury 40 cases accompanied with posterior cruciate ligament rupture in 16 cases, hyperextension injury. 9 cases accompanied with anterior cruciate ligament rupture in 2 cases, posterior cruciate ligament rupture in 3 cases. No lateral patellar dislocation was found. Forty-eight of 145 patients had undergone arthroscopy, 43 cases (89.6%) of them were in accordance with Mill diagnosis. Bone contusion were defined as geographic regions of abnormal signal intensity, that is, low signal intensity in T 1 -weighted images and high signal intensity in PD-weighted or T 2 -weigeted images with fat saturation. Conclusion: MRI can accurately display the location and area of bone contusion of the knee joint as well as its adjunctive structure injury and deduce their injury mechanism. MRI should be used routinely for knee trauma. (authors)

  18. Knee arthritis pain is reduced and range of motion is increased following moderate pressure massage therapy.

    Science.gov (United States)

    Field, Tiffany; Diego, Miguel; Gonzalez, Gladys; Funk, C G

    2015-11-01

    The literature on massage therapy effects on knee pain suggests that pain was reduced based on self-report, but little is known about range of motion (ROM) effects. Medical School staff and faculty who had knee arthritis pain were randomly assigned to a moderate pressure massage therapy or a waitlist control group (24 per group). Self-reports included the WOMAC (pain, stiffness and function) and the Pittsburgh Sleep Quality Index. ROM and ROM-related pain were assessed before and after the last sessions. The massage group showed an immediate post-massage increase in ROM and a decrease in ROM-associated pain. On the last versus the first day of the study, the massage group showed greater increases in ROM and decreases in ROM-related pain as well as less self-reported pain and sleep disturbances than the waitlist control group. These data highlight the effectiveness of moderate pressure massage therapy for increasing ROM and lessening ROM-related pain and long-term pain and sleep disturbances. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Quantifying frontal plane knee motion during single limb squats: reliability and validity of 2-dimensional measures.

    Science.gov (United States)

    Gwynne, Craig R; Curran, Sarah A

    2014-12-01

    Clinical assessment of lower limb kinematics during dynamic tasks may identify individuals who demonstrate abnormal movement patterns that may lead to etiology of exacerbation of knee conditions such as patellofemoral joint (PFJt) pain. The purpose of this study was to determine the reliability, validity and associated measurement error of a clinically appropriate two-dimensional (2-D) procedure of quantifying frontal plane knee alignment during single limb squats. Nine female and nine male recreationally active subjects with no history of PFJt pain had frontal plane limb alignment assessed using three-dimensional (3-D) motion analysis and digital video cameras (2-D analysis) while performing single limb squats. The association between 2-D and 3-D measures was quantified using Pearson's product correlation coefficients. Intraclass correlation coefficients (ICCs) were determined for within- and between-session reliability of 2-D data and standard error of measurement (SEM) was used to establish measurement error. Frontal plane limb alignment assessed with 2-D analysis demonstrated good correlation compared with 3-D methods (r = 0.64 to 0.78, p < 0.001). Within-session (0.86) and between-session ICCs (0.74) demonstrated good reliability for 2-D measures and SEM scores ranged from 2° to 4°. 2-D measures have good consistency and may provide a valid measure of lower limb alignment when compared to existing 3-D methods. Assessment of lower limb kinematics using 2-D methods may be an accurate and clinically useful alternative to 3-D motion analysis when identifying individuals who demonstrate abnormal movement patterns associated with PFJt pain. 2b.

  20. Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator.

    Science.gov (United States)

    Liu, Aiqin; Jennings, Louise M; Ingham, Eileen; Fisher, John

    2015-09-18

    The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine knee model using a whole joint knee simulator for investigation of the tribological function and biomechanical properties of the natural knee, which could then be used to pre-clinically assess the tribological performance of cartilage and meniscal repair interventions prior to in vivo studies. The tribological performance of standard artificial bearings in terms of anterior-posterior (A/P) shear force was determined in a newly developed six degrees of freedom tribological joint simulator. The porcine knee model was then developed and the tribological properties in terms of shear force measurements were determined for the first time for three levels of biomechanical constraints including A/P constrained, spring force semi-constrained and A/P unconstrained conditions. The shear force measurements showed higher values under the A/P constrained condition (predominantly sliding motion) compared to the A/P unconstrained condition (predominantly rolling motion). This indicated that the shear force simulation model was able to differentiate between tribological behaviours when the femoral and tibial bearing was constrained to slide or/and roll. Therefore, this porcine knee model showed the potential capability to investigate the effect of knee structural, biomechanical and kinematic changes, as well as different cartilage substitution therapies on the tribological function of natural knee joints. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Comparison of Multisegmental Foot and Ankle Motion Between Total Ankle Replacement and Ankle Arthrodesis in Adults.

    Science.gov (United States)

    Seo, Sang Gyo; Kim, Eo Jin; Lee, Doo Jae; Bae, Kee Jeong; Lee, Kyoung Min; Lee, Dong Yeon

    2017-09-01

    Total ankle replacement (TAR) and ankle arthrodesis (AA) are usually performed for severe ankle arthritis. We compared postoperative foot segmental motion during gait in patients treated with TAR and AA. Gait analysis was performed in 17 and 7 patients undergoing TAR and AA, respectively. Subjects were evaluated using a 3-dimensional multisegmental foot model with 15 markers. Temporal gait parameters were calculated. The maximum and minimum values and the differences in hallux, forefoot, hindfoot, and arch in 3 planes (sagittal, coronal, transverse) were compared between the 2 groups. One hundred healthy adults were evaluated as a control. Gait speed was faster in the TAR ( P = .028). On analysis of foot and ankle segmental motion, the range of hindfoot sagittal motion was significantly greater in the TAR (15.1 vs 10.2 degrees in AA; P = .004). The main component of motion increase was hindfoot dorsiflexion (12.3 and 8.6 degrees). The range of forefoot sagittal motion was greater in the TAR (9.3 vs 5.8 degrees in AA; P = .004). Maximum ankle power in the TAR (1.16) was significantly higher than 0.32 in AA; P = .008). However, the range of hindfoot and forefoot sagittal motion was decreased in both TAR and AA compared with the control group ( P = .000). Although biomechanical results of TAR and AA were not similar to those in the normal controls, joint motions in the TAR more closely matched normal values. Treatment decision making should involve considerations of the effect of surgery on the adjacent joints. Level III, case-control study.

  2. Radial MR images of the knee

    International Nuclear Information System (INIS)

    Hewes, R.C.; Miller, T.R.

    1988-01-01

    To profile optimally each portion of the meniscus, the authors use the multiangle, multisection feature of a General Electric SIGNA 1.5-T imager to produce radial images centered on each meniscus. A total of 12-15 sections are imaged at 10 0 -15 0 intervals of each meniscus, yielding perpendicular images of the entire meniscus, comparable with the arthrographic tangential views. The authors review their technique and demonstrate correlation cases between the radial gradient recalled acquisition in a steady state sequences, sagittal and coronal MR images, and arthrograms. Radial images should be a routine part of knee MR imaging

  3. Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?

    Directory of Open Access Journals (Sweden)

    Rasch Helmut

    2011-02-01

    Full Text Available Abstract Background The purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA. Methods Twenty-three painful knees in patients following primary TKA were assessed using Tc-99m-HDP-SPECT/CT. Rotational, sagittal and coronal position of the TKA was assessed on 3D-CT reconstructions. The level of the SPECT-tracer uptake (0-10 and its anatomical distribution was mapped using a validated localization scheme. Univariate analysis (Wilcoxon-Mann-Whitney, Spearmean`s-rho test, p Results SPECT/CT imaging changed the suspected diagnosis and the proposed treatment in 19/23 (83% knees. Progression of patellofemoral OA (n = 11, loosening of the tibial (n = 3 and loosening of the femoral component (n = 2 were identified as the leading causes of pain after TKA. Patients with externally rotated tibial trays showed higher tracer uptake in the medial patellar facet (p = 0.049 and in the femur (p = 0.051. Patients with knee pain due to patellofemoral OA showed significantly higher tracer uptake in the patella than others (p Conclusions SPECT/CT was very helpful in establishing the diagnosis and guiding subsequent management in patients with painful knees after TKA, particularly in patients with patellofemoral problems and malpositioned or loose TKA.

  4. Variability of Measurement of Patellofemoral Indices with Knee Flexion and Quadriceps Contraction: An MRI-Based Anatomical Study

    Science.gov (United States)

    Laugharne, Edward; Bali, Navi; Purushothamdas, Sanjay; Almallah, Faris; Kundra, Rik

    2016-01-01

    Purpose The purpose of this study was to investigate the impact of varying knee flexion and quadriceps activity on patellofemoral indices measured on magnetic resonance imaging (MRI). Materials and Methods MRI of the knee was performed in 20 patients for indications other than patellar or patellofemoral pathology. Axial and sagittal sequences were performed in full extension of the knee with the quadriceps relaxed, full extension of the knee with the quadriceps contracted, 30° flexion of the knee with the quadriceps relaxed, and 30° flexion with the quadriceps contracted. Bisect offset, patella tilt angle, Insall-Salvati ratio and Caton-Deschamps index were measured. Results With the knee flexed to 30° and quadriceps relaxed, the mean values of patellar tilt angle, bisect offset, Insall-Salvati ratio and Caton-Deschamps index were all within normal limits. With the knee extended and quadriceps contracted, the mean patellar tilt angle (normal value, patellofemoral indices. MRI taken with the knee in 30° of flexion allows more reliable assessment of the patellofemoral joint and minimises the confounding effect of quadriceps contraction. PMID:27894177

  5. MR imaging of the knee extension and flexion. Diagnostic value for reconstructed anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, Mamoru; Ikeda, Kotaroh; Fukubayashi, Tohru [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine] [and others

    1995-09-01

    The purpose of this study is to determine the value of extended and flexed knee positions in MR imaging of the surgically reconstructed anterior cruciate ligament (ACL). With a mobile knee brace and a flexible surface coil, knee joint was enabled to extend to a full-extension and bend vertically to a semi-flexion (average 45deg of flexion) within the confines of the magnet bore. Sets of 3-mm-thick oblique sagittal proton-weighted turbo spin echo MR images were obtained at both extended and flexed positions. Twenty-five knees with intact ACL grafts and three knees with arthroscopically proved graft tears were evaluated. Compared to the extended position, MR images of flexed knee provided better delineation of the intact and complicated ACL grafts with statistical significance. The intact graft appeared relaxed at the semi-flexion and taut at the extension. Overall lengths of the intact grafts were readily identified at the flexion. Stretched along the intercondylar roof, the grafts were poorly outlined at the extension. MR images with knee flexion delineated the disrupted site from the impingement more clearly than that with knee extension. (author).

  6. Effects of neuromuscular fatigue on perceptual-cognitive skills between genders in the contribution to the knee joint loading during side-stepping tasks.

    Science.gov (United States)

    Khalid, Abdul Jabbar; Harris, Sujae Ian; Michael, Loke; Joseph, Hamill; Qu, Xingda

    2015-01-01

    This study investigated whether neuromuscular fatigue affects the neuromuscular control of an athlete within a sports context setting and whether these effects were more pronounced in the females. Lower limb joint kinetics of 6 male and 6 female inter-varsity soccer players performing side-stepping tasks in non-fatigue versus fatigue and anticipated versus unanticipated conditions were quantified using 10 Motion Analysis Corporation cameras and a Kistler(™) force platform. The Yo-Yo intermittent recovery Level 1 fatigue protocol was employed. Stance foot initial contact and peak forces, and peak joint knee moments of the lower limb were submitted to a 3-way mixed-model repeated measure ANOVA. The results suggested that males tend to elicit significantly higher knee joint loadings when fatigued. In addition, males elicited significantly higher peak proximal tibia anterior/posterior shear force, vertical ground reaction force at initial contact and peak internal rotational moments than females. These findings suggested that males were at greater overall injury risk than females, especially in the sagittal plane. Neuromuscular control-based training programmes/interventions that are designed to reduce the risk of the non-contact ACL injury need to be customised for the different genders.

  7. [Knee disarticulation and through-knee amputation].

    Science.gov (United States)

    Baumgartner, R

    2011-10-01

    A knee disarticulation or a through-knee stump is superior compared to a transfemoral stump. The thigh muscles are all preserved, and the muscle balance remains undisturbed. The range of motion of the hip joint is not limited. The bulbous shape of the stump allows full weight bearing at the stump end and can easily be fitted with a prosthesis. An amputee with a bilateral knee disarticulation is able to walk "barefoot". A more distal amputation level, e.g., an ultra-short transtibial amputation, is not possible. Important alternative to transfemoral amputations. Possible for any etiology except for Buerger-Winiwarter's disease. New indications are infected and loosened total knee replacements. Preservation of the knee joint is possible. Knee disarticulation is a very atraumatic procedure, compared to transfemoral amputations. Neither bones nor muscles have to be severed, just skin, ligaments, vessels, and nerves. Even the meniscal cartilages may be left in place to act as axial shock absorbers. The cartilage of the femur is not resected, but only bevelled in case of osteoarthritis. There are no tendon attachments or myoplastic procedures necessary. The patella remains in place and is held in position only by the retinacula. Skin closure must be performed without the slightest tension, and if possible not in the weight-bearing area. Transcondylar amputations across the femoral condyles only are indicated when there are not sufficient soft tissues for wound closure of a knee disarticulation. Alternatives as the techniques of Gritti, Klaes, and Eigler, the shortening of the femur and the Sauerbruch's rotation plasty [14] are presented and discussed. The risk of decubital ulcers is rather high. Correct bandaging of the stump is, therefore, particularly important. Prosthetic fitting is possible 3-6 weeks after surgery. The type of prosthesis depends on the amputee's activity level. The superior performance of amputees with knee disarticulations in sports prove the

  8. Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.

    Science.gov (United States)

    Berti, Lisa; Benedetti, Maria Grazia; Ensini, Andrea; Catani, Fabio; Giannini, Sandro

    2006-07-01

    Currently there is a limited understanding of the factors influencing range of motion by comparing patellar resurfacing vs non-resurfacing in total knee arthroplasty during activities of daily living. A recent meta-analysis of patellar replacement confirms better outcome with patella resurfacing; however, the result can be influenced by many other factors, such as: component design, surgeon experience, and technical aspects of the surgery. This study compares the biomechanics of the knee in patients after total knee arthroplasty with and without patellar resurfacing during stair climbing. Forty-seven patients with total knee arthroplasty were assessed at the mean follow-up of 24 months. In all of them a posterior stabilised fixed bearing prosthesis (Optetrak PS, Exactech) was implanted. Twenty-six patients were treated without patellar resurfacing and 21 with patellar resurfacing. Clinical evaluations were performed using the International Knee Society and the Hospital for Special Surgery scores. Ten patients with patellar resurfacing and 10 patients without patellar resurfacing were also studied with motion analysis during stair climbing; 10 healthy subjects were studied for statistical comparison. Clinical passive knee flexion, International Knee Society Function and Hospital for Special Surgery scores were significantly higher in the patellar resurfacing group. During stair climbing, active knee joint range of motion during the stance phase was greater in patients with patellar resurfacing. The maximum adduction moment was significantly higher in the group without patellar resurfacing. Patients with patellar resurfacing demonstrated better clinical scores, and kinematic and kinetic data while ascending stairs.

  9. Effects of Spine Motion on Foot Slip in Quadruped Bounding

    Directory of Open Access Journals (Sweden)

    Dongliang Chen

    2018-01-01

    Full Text Available Translation and bend of the spine in the sagittal plane during high-speed quadruped running were investigated. The effect of the two spine motions on slip between the foot and the ground was also explored. First, three simplified sagittal plane models of quadruped mammals were studied in symmetric bounding. The first model’s trunk allowed no relative motion, the second model allowed only trunk bend, and the third model allowed both bend and translation. Next, torque was introduced to equivalently replace spine motion and the possibility of foot slip of the three models was analyzed theoretically. The results indicate that the third model has the least possibility of slip. This conclusion was further confirmed by simulation experiments. Finally, the conclusion was verified by the reductive model crawling robot.

  10. New Generation Lockable Knee Brace

    Science.gov (United States)

    2000-01-01

    A knee brace that uses Space Shuttle propulsion technology has moved a step closer to being available to help knee injury and stroke patients and may possibly benefit patients with birth defects, spinal cord injuries, and post-polio conditions. After years of hard work, inventors at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama, have turned over the final design and prototype to industry partners at Horton's Orthotic Lab in Little Rock, Arkansas for further clinical testing. The device, called the Selectively Lockable Knee Brace, may mean faster, less painful rehabilitation for patients by allowing the knee to move when weight is not on the heel. Devices currently on the market lock the knee in a rigid, straight-leg position, or allow continuous free motion. The knee brace is just one example of how space technology is being used to improve the lives of people on Earth. NASA's MSFC inventors Michael Shadoan and Neill Myers are space propulsion engineers who use the same mechanisms and materials to build systems for rockets that they used to design and develop the knee brace.

  11. Changes in fatigue, multiplanar knee laxity, and landing biomechanics during intermittent exercise.

    Science.gov (United States)

    Shultz, Sandra J; Schmitz, Randy J; Cone, John R; Henson, Robert A; Montgomery, Melissa M; Pye, Michele L; Tritsch, Amanda J

    2015-05-01

    Knee laxity increases during exercise. However, no one, to our knowledge, has examined whether these increases contribute to higher-risk landing biomechanics during prolonged, fatiguing exercise. To examine associations between changes in fatigue (measured as sprint time [SPTIME]), multiplanar knee laxity (anterior-posterior [APLAX], varus-valgus [VVLAX] knee laxity, and internal-external rotation [IERLAX]) knee laxity and landing biomechanics during prolonged, intermittent exercise. Descriptive laboratory study. Laboratory and gymnasium. A total of 30 male (age = 20.3 ± 2.0 years, height = 1.79 ± 0.05 m, mass = 75.2 ± 7.2 kg) and 29 female (age = 20.5 ± 2.3 years, height = 1.67 ± 0.08 m, mass = 61.8 ± 9.0 kg) competitive athletes. A 90-minute intermittent exercise protocol (IEP) designed to simulate the physiologic and biomechanical demands of a soccer match. We measured SPTIME, APLAX, and landing biomechanics before and after warm-up, every 15 minutes during the IEP, and every 15 minutes for 1 hour after the IEP. We measured VVLAX and IERLAX before and after the warm-up, at 45 and 90 minutes during the IEP, and at 30 minutes after the IEP. We used hierarchical linear modeling to examine associations between exercise-related changes in SPTIME and knee laxity with exercise-related changes in landing biomechanics while controlling for initial (before warm-up) knee laxity. We found that SPTIME had a more global effect on landing biomechanics in women than in men, resulting in a more upright landing and a reduction in landing forces and out-of-plane motions about the knee. As APLAX increased with exercise, women increased their knee internal-rotation motion (P = .02), and men increased their hip-flexion motion and energy-absorption (P = .006) and knee-extensor loads (P = .04). As VVLAX and IERLAX increased, women went through greater knee-valgus motion and dorsiflexion and absorbed more energy at the knee (P ≤ .05), whereas men were positioned in greater hip

  12. Surgical Stabilization of the Medial Capsulo-Ligamentous Envelope in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Brandon Green, DO

    2014-10-01

    Full Text Available This study will evaluate an alternative method in which a four prong bone staple was used to repair the medial collateral ligament following over-release or avulsion injuries in (#6 cases during a total knee arthroplasty. The use of a four prong bone staple to repair medial collateral ligament injuries status post total knee replacement will provide satisfactory results with respect to post-operative knee stability and range of motion. Our retrospective review revealed that all six patients improved with regards to range of motion following the total knee arthroplasty. We feel that repair of the medial collateral ligament with a four-prong bone staple is a viable option after an over-release or avulsion injury sustained during a total knee arthroplasty.

  13. Knee flexion contractures in institutionalized elderly: prevalence, severity, stability, and related variables.

    Science.gov (United States)

    Mollinger, L A; Steffen, T M

    1993-07-01

    The purpose of this study was to document the prevalence, severity, and progression of knee flexion contractures (KFCs) in a population of institutionalized elderly and to identify relationships between knee extension and other variables. The subjects were 112 nursing home residents who exhibited a broad range of ambulation and cognitive function abilities. Data were collected initially (T1) and after a 10-month period (T2). Only 25% of the population had extension in the 0- to 5-degree (lacking full extension) range bilaterally at T1 and T2, leaving the majority of subjects with some degree of unilateral KFC. Most of the subjects with a KFC greater than 20 degrees were nonambulatory and had a significantly higher occurrence of resistance to motion than did nonambulators with a KFC of less than 20 degrees. Knee extension measurements did not change in most subjects between T1 and T2. The knees that did show a change in KFC (either an increase or a decrease) had a significantly higher occurrence of resistance to passive motion than did other knees. Compared with the subjects who gained extension, the subjects who lost extension over the study period more frequently had minimal KFC at T1, were ambulatory at T1, showed a regression in ambulation at T2, and developed resistance to motion at T2. The data confirmed significant positive correlations between degree of KFC and presence of resistance to passive knee motion, cognitive impairment, impaired ambulation, and presence of knee pain. Physical therapy assessment and intervention may be appropriate in nonambulatory nursing home residents with resistance to passive motion, residents with KFC approaching 20 degrees, and ambulatory residents with minimal KFC who develop resistance and begin to regress in ambulation. Several areas for future study are suggested.

  14. Sagittal crest formation in great apes and gibbons

    OpenAIRE

    Balolia, K. L.; Soligo, C.; Wood, B.

    2017-01-01

    The frequency of sagittal crest expression and patterns of sagittal crest growth and development have been documented in hominoids, including some extinct hominin taxa, and the more frequent expression of the sagittal crest in males has been traditionally linked with the need for larger-bodied individuals to have enough attachment area for the temporalis muscle. In the present study, we investigate sagittal cresting in a dentally mature sample of four hominoid taxa (Pan troglodytes schweinfur...

  15. The influence of motion control shoes on the running gait of mature and young females.

    Science.gov (United States)

    Lilley, Kim; Stiles, Vicky; Dixon, Sharon

    2013-03-01

    This study compared the running gait of mature and young females, and investigated the effect of a motion control shoe. First, it was hypothesised that in a neutral shoe, mature females would display significantly greater rearfoot eversion, knee internal rotation and external adductor moments when compared to a younger group. Secondly, the motion control shoe would reduce rearfoot eversion and knee internal rotation in both groups. Thirdly it was hypothesised that the motion control shoe would increase knee external adductor moment, through an increase in knee varus and moment arm. 15 mature (40-60 years) and 15 young (18-25 years) females performed 10 running trials at 3.5ms(-1)±5% over a force platform. Two shoes were tested, the Adidas Supernova Glide (neutral), and the Adidas Supernova Sequence (motion control). Ankle and knee joint dynamics were analysed for the right leg, and the mean of ten trials was calculated. Joint moments were calculated using inverse dynamics. In the neutral condition, mature females presented greater peak rearfoot eversion, knee internal rotation, and external adductor moments than young females (p<0.05). A motion control shoe significantly reduced peak rearfoot eversion and knee internal rotation among both groups (p<0.05). No between shoe differences in knee external adductor moment were observed. A motion control shoe is recommended to reduce risk of injury associated with rearfoot eversion and knee internal rotation in mature females. However since the knee external adductor moment is a variable commonly associated with medial knee loading it is suggested that alternative design features are required to influence this moment. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Analysis of sagittal spinopelvic parameters in achondroplasia.

    Science.gov (United States)

    Hong, Jae-Young; Suh, Seung-Woo; Modi, Hitesh N; Park, Jong-Woong; Park, Jung-Ho

    2011-08-15

    Prospective radiological analysis of patients with achondroplasia. To analyze sagittal spinal alignment and pelvic orientation in achondroplasia patients. Knowledge of sagittal spinopelvic parameters is important for the treatment of achondroplasia, because they differ from those of the normal population and can induce pain. The study and control groups were composed of 32 achondroplasia patients and 24 healthy volunteers, respectively. All underwent lateral radiography of the whole spine including hip joints. The radiographic parameters examined were sacral slope (SS), pelvic tilt, pelvic incidence (PI), S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis (LL1, LL2), and sagittal balance. Statistical analysis was performed to identify significant differences between the two groups. In addition, correlations between parameters and symptoms were sought. Sagittal spinopelvic parameters, namely, pelvic tilt, pelvic incidence, S1 overhang, thoracic kyphosis, T10-L2 kyphosis, lumbar lordosis 1 and sagittal balance were found to be significantly different in the patient and control groups (P achondroplasia patients and normal healthy controls. The present study shows that sagittal spinal and pelvic parameters can assist the treatment of spinal disorders in achondroplasia patients.

  17. Are the kinematics of the knee joint altered during the loading response phase of gait in individuals with concurrent knee osteoarthritis and complaints of joint instability? A dynamic stereo X-ray study.

    Science.gov (United States)

    Farrokhi, Shawn; Tashman, Scott; Gil, Alexandra B; Klatt, Brian A; Fitzgerald, G Kelley

    2012-05-01

    Joint instability has been suggested as a risk factor for knee osteoarthritis and a cause of significant functional decline in those with symptomatic disease. However, the relationship between altered knee joint mechanics and self-reports of instability in individuals with knee osteoarthritis remains unclear. Fourteen subjects with knee osteoarthritis and complaints of joint instability and 12 control volunteers with no history of knee disease were recruited for this study. Dynamic stereo X-ray technology was used to assess the three-dimensional kinematics of the knee joint during the loading response phase of gait. Individuals with concurrent knee osteoarthritis and joint instability demonstrated significantly reduced flexion and internal/external rotation knee motion excursions during the loading response phase of gait (Pknee joint at initial contact was significantly different (Pknee osteoarthritis and joint instability. However, the anteroposterior and mediolateral tibiofemoral joint positions at initial contact and the corresponding total joint translations were similar between groups during the loading phase of gait. The rotational patterns of tibiofemoral joint motion and joint alignments reported for individuals with concurrent knee osteoarthritis and joint instability are consistent with those previously established for individuals with knee osteoarthritis. Furthermore, the findings of similar translatory tibiofemoral motion between groups suggest that self-reports of episodic joint instability in individuals with knee osteoarthritis may not necessarily be associated with adaptive alterations in joint arthrokinematics. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Prospective Study of the Relation between Landing Biomechanics and Jumper's Knee

    NARCIS (Netherlands)

    der Worp, H van; van der Does, H T D; Brink, M.S.; Zwerver, J.; Hijmans, J.M.

    The literature on the relation between jump biomechanics and jumper's knee indicates that a jump with horizontal displacement poses a threat for developing jumper's knee. Subjects with jumper's knee have been shown to display a stiff landing pattern characterized by a small range of motion. However,

  19. Analysis of knee movement with low-field MR equipment. A normal volunteer study

    International Nuclear Information System (INIS)

    Ando, Yoko; Fukatsu, Hiroshi; Ishigaki, Takeo; Aoki, Ikuo; Yamada, Takashi.

    1994-01-01

    This study was performed to make a normal standard by analyzing knee movement in detail. An open low-field unit was used for 23 healthy knee joints. With three-dimensional Fourier transformation (3DFT) gradient echo sequence, 50 sagittal slices of 4.5 mm in thickness were obtained at four flexion angles: 0, 30, 60, and 90 degrees (lateral position). Although the tension ratio of the anterior and posterior cruciate ligaments (ACL, PCL) increased during knee flexion, the change in the tension ratio was significantly different between the ACL and PCL. The femur-ACL angle and femur-PCL angle were parallel with the knee flexion angle, but the tibia-ACL angle and tibia-PCL angle changed complexly. The lateral and medial condyles rolled and slid during knee flexion, and the medial side moved more than the lateral side, consistent with rotation of the lower thigh. The difference in backward movement distance on the tibia between the two condyles was significantly larger in females than in males. This might explain the dominance of knee osteoarthritis in women. Although the lateral position is not completely physiological, we could show initial cinematic data of up to 90 degrees of knee flexion using open-type MRI, which is impossible with high- and middle-field machines. (author)

  20. Effects of toe-in and toe-in with wider step width on level walking knee biomechanics in varus, valgus, and neutral knee alignments.

    Science.gov (United States)

    Bennett, Hunter J; Shen, Guangping; Cates, Harold E; Zhang, Songning

    2017-12-01

    Increased peak external knee adduction moments exist for individuals with knee osteoarthritis and varus knee alignments, compared to healthy and neutrally aligned counterparts. Walking with increased toe-in or increased step width have been individually utilized to successfully reduce 1st and 2nd peak knee adduction moments, respectfully, but have not previously been combined or tested among all alignment groups. The purpose of this study was to compare toe-in only and toe-in with wider step width gait modifications in individuals with neutral, valgus, and varus alignments. Thirty-eight healthy participants with confirmed varus, neutral, or valgus frontal-plane knee alignment through anteroposterior radiographs, performed level walking in normal, toe-in, and toe-in with wider step width gaits. A 3×3 (group×intervention) mixed model repeated measures ANOVA compared alignment groups and gait interventions (pstep width compared to normal gait. The 2nd peak adduction moment was increased in toe-in compared to normal and toe-in with wider step width. The adduction impulse was also reduced in toe-in and toe-in with wider step width compared to normal gait. Peak knee flexion and external rotation moments were increased in toe-in and toe-in with wider step width compared to normal gait. Although the toe-in with wider step width gait seems to be a viable option to reduce peak adduction moments for varus alignments, sagittal, and transverse knee loadings should be monitored when implementing this gait modification strategy. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Symptomatic versus asymptomatic knees after bilateral total knee arthroplasty: what is the difference in SPECT/CT?

    Energy Technology Data Exchange (ETDEWEB)

    Awengen, R.; Hirschmann, M.T. [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); Rasch, H. [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Institute of Radiology and Nuclear Medicine, Bruderholz (Switzerland); Amsler, F. [Amsler Consulting, Basel (Switzerland)

    2016-04-15

    The primary purpose of this retrospective study was to evaluate the differences of bone tracer uptake (BTU) in symptomatic and asymptomatic knees after bilateral total knee arthroplasty (TKA) and identify typical BTU patterns with regards to TKA component position and alignment. A consecutive number of 37 patients after bilateral TKA were retrospectively included. The knees were grouped into symptomatic (group A) and asymptomatic (group B) knees. All patients underwent 99m-Tc-HDP-SPECT/CT. Coronal, rotational, and sagittal TKA component position was analysed in 3D reconstructed CT. BTU was anatomically localised and quantified using a validated standardized localization scheme. Maximum BTU values for each area were recorded and normalized values calculated. Signed log-rank test, chi-square test, paired t-tests, and Pearson correlations were used (p <0.05). Symptomatic TKAs were significantly more flexed and had a tendency to be more internally rotated when compared to asymptomatic ones (p < 0.05). In all regions, the mean BTU in asymptomatic knees was lower than in symptomatic knees. In both groups the highest mean BTU was found around the tibial stem (symptomatic 7.30; asymptomatic 6.30, p = 0.061) and at the tip of the tibial stem (symptomatic 5.49; asymptomatic 4.74, p = 0.062). Superior patellar regions showed higher BTU than inferior regions. The highest patellar BTU was found in the superior medial patella (symptomatic 4.99; asymptomatic 3.98, p = 0.048). The lowest BTU was found in the posterior femoral regions (flatsp, flatip, fmedsp, fmedip) (Table 3). Tibial and patellar areas showed twice as high mean BTUs than femoral areas (Fig. 3). A significant correlation of TKA component position and BTU was demonstrated. Distribution and intensity of BTU in SPECT/CT depends on TKA component position and alignment. In addition, typical BTU patterns in symptomatic and asymptomatic knees were identified. A profound knowledge of BTU pattern, TKA component position

  2. The effect of ankle bracing on knee kinetics and kinematics during volleyball-specific tasks.

    Science.gov (United States)

    West, T; Ng, L; Campbell, A

    2014-12-01

    The purpose of this study was to examine the effects of ankle bracing on knee kinetics and kinematics during volleyball tasks. Fifteen healthy, elite, female volleyball players performed a series of straight-line and lateral volleyball tasks with no brace and when wearing an ankle brace. A 14-camera Vicon motion analysis system and AMTI force plate were used to capture the kinetic and kinematic data. Knee range of motion, peak knee anterior-posterior and medial-lateral shear forces, and peak ground reaction forces that occurred between initial contact with the force plate and toe off were compared using paired sample t-tests between the braced and non-braced conditions (P volleyball tasks. However, ankle bracing was demonstrated to reduce knee lateral shear forces during all of the lateral movement volleyball tasks. Wearing the Active Ankle T2 brace will not impact knee joint range of motion and may in fact reduce shear loading to the knee joint in volleyball players. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Knock knee and the gait of six-year-old children.

    Science.gov (United States)

    Pretkiewicz-Abacjew, E

    2003-06-01

    Knock knee (genu valgum) interferes with the locomotive and supporting function of the lower limb. In static conditions the load-bearing axis of the valgus limb is displaced laterally in relation to the middle of the joint, causing the knee joint, the ankle joint, and the foot as a whole to be weighted in the wrong way. The purpose of this work is to examine the influence of knock knee on gait kinematics. The gait of twenty-two 6-year-old children of both sexes in whom knock knee had been medically diagnosed was compared with the gait of 33 children of the same age whose knee joints conformed to the norm in formation and position. Gait was recorded separately for the sagittal and the frontal planes, using a video-computer system. The results of the examination indicated statistically significant differences in the gait of the two groups of children. These differences related mainly to the time features of gait and to data on the angles in the knee and ankle joints. Although the results obtained for other features of gait did not reveal statistical differences, these did indicate that the children with knock knee walked more slowly and with a lower cadence. The results indicate that knock knee in 6-year-old children has an adverse impact on the mechanics of the lower limb joints in gait and causes a deterioration in gait quality. Thus knock knee in children should not be treated merely as a superficial defect but should be subject to therapy and, more importantly, taken into account when introducing children to early sports training.

  4. The associations between quadriceps muscle strength, power, and knee joint mechanics in knee osteoarthritis: A cross-sectional study.

    Science.gov (United States)

    Murray, Amanda M; Thomas, Abbey C; Armstrong, Charles W; Pietrosimone, Brian G; Tevald, Michael A

    2015-12-01

    Abnormal knee joint mechanics have been implicated in the pathogenesis and progression of knee osteoarthritis. Deficits in muscle function (i.e., strength and power) may contribute to abnormal knee joint loading. The associations between quadriceps strength, power and knee joint mechanics remain unclear in knee osteoarthritis. Three-dimensional motion analysis was used to collect peak knee joint angles and moments during the first 50% of stance phase of gait in 33 participants with knee osteoarthritis. Quadriceps strength and power were assessed using a knee extension machine. Strength was quantified as the one repetition maximum. Power was quantified as the peak power produced at 40-90% of the one repetition maximum. Quadriceps strength accounted for 15% of the variance in peak knee flexion angle (P=0.016). Quadriceps power accounted for 20-29% of the variance in peak knee flexion angle (Pknee adduction moment (P=0.05). These data suggest that quadriceps power explains more variance in knee flexion angle and knee adduction moment during gait in knee osteoarthritis than quadriceps strength. Additionally, quadriceps power at multiple loads is associated with knee joint mechanics and therefore should be assessed at a variety of loads. Taken together, these results indicate that quadriceps power may be a potential target for interventions aimed at changing knee joint mechanics in knee osteoarthritis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Topographic deformation patterns of knee cartilage after exercises with high knee flexion: an in vivo 3D MRI study using voxel-based analysis at 3T

    International Nuclear Information System (INIS)

    Horng, Annie; Stockinger, M.; Notohamiprodjo, M.; Raya, J.G.; Pietschmann, M.; Hoehne-Hueckstaedt, U.; Glitsch, U.; Ellegast, R.; Hering, K.G.; Glaser, C.

    2015-01-01

    To implement a novel voxel-based technique to identify statistically significant local cartilage deformation and analyze in-vivo topographic knee cartilage deformation patterns using a voxel-based thickness map approach for high-flexion postures. Sagittal 3T 3D-T1w-FLASH-WE-sequences of 10 healthy knees were acquired before and immediately after loading (kneeling/squatting/heel sitting/knee bends). After cartilage segmentation, 3D-reconstruction and 3D-registration, colour-coded deformation maps were generated by voxel-based subtraction of loaded from unloaded datasets to visualize cartilage thickness changes in all knee compartments. Compression areas were found bifocal at the peripheral medial/caudolateral patella, both posterior femoral condyles and both anterior/central tibiae. Local cartilage thickening were found adjacent to the compression areas. Significant local strain ranged from +13 to -15 %. Changes were most pronounced after squatting, least after knee bends. Shape and location of deformation areas varied slightly with the loading paradigm, but followed a similar pattern consistent between different individuals. Voxel-based deformation maps identify individual in-vivo load-specific and posture-associated strain distribution in the articular cartilage. The data facilitate understanding individual knee loading properties and contribute to improve biomechanical 3 models. They lay a base to investigate the relationship between cartilage degeneration patterns in common osteoarthritis and areas at risk of cartilage wear due to mechanical loading in work-related activities. (orig.)

  6. Topographic deformation patterns of knee cartilage after exercises with high knee flexion: an in vivo 3D MRI study using voxel-based analysis at 3T

    Energy Technology Data Exchange (ETDEWEB)

    Horng, Annie; Stockinger, M.; Notohamiprodjo, M. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Raya, J.G. [New York University Langone Medical Center, Center for Biomedical Imaging, New York, NY (United States); Pietschmann, M. [Ludwig-Maximilians-University Hospital Munich, Department of Orthopedic Surgery, Munich (Germany); Hoehne-Hueckstaedt, U.; Glitsch, U.; Ellegast, R. [Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA), Sankt Augustin (Germany); Hering, K.G. [Miner' s Hospital, Department of Diagnostic Radiology, Dortmund (Germany); Glaser, C. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); RZM Zentrum, Munich (Germany)

    2015-06-01

    To implement a novel voxel-based technique to identify statistically significant local cartilage deformation and analyze in-vivo topographic knee cartilage deformation patterns using a voxel-based thickness map approach for high-flexion postures. Sagittal 3T 3D-T1w-FLASH-WE-sequences of 10 healthy knees were acquired before and immediately after loading (kneeling/squatting/heel sitting/knee bends). After cartilage segmentation, 3D-reconstruction and 3D-registration, colour-coded deformation maps were generated by voxel-based subtraction of loaded from unloaded datasets to visualize cartilage thickness changes in all knee compartments. Compression areas were found bifocal at the peripheral medial/caudolateral patella, both posterior femoral condyles and both anterior/central tibiae. Local cartilage thickening were found adjacent to the compression areas. Significant local strain ranged from +13 to -15 %. Changes were most pronounced after squatting, least after knee bends. Shape and location of deformation areas varied slightly with the loading paradigm, but followed a similar pattern consistent between different individuals. Voxel-based deformation maps identify individual in-vivo load-specific and posture-associated strain distribution in the articular cartilage. The data facilitate understanding individual knee loading properties and contribute to improve biomechanical 3 models. They lay a base to investigate the relationship between cartilage degeneration patterns in common osteoarthritis and areas at risk of cartilage wear due to mechanical loading in work-related activities. (orig.)

  7. Using ground reaction force to predict knee kinetic asymmetry following anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Dai, B; Butler, R J; Garrett, W E; Queen, R M

    2014-12-01

    Asymmetries in sagittal plane knee kinetics have been identified as a risk factor for anterior cruciate ligament (ACL) re-injury. Clinical tools are needed to identify the asymmetries. This study examined the relationships between knee kinetic asymmetries and ground reaction force (GRF) asymmetries during athletic tasks in adolescent patients following ACL reconstruction (ACL-R). Kinematic and GRF data were collected during a stop-jump task and a side-cutting task for 23 patients. Asymmetry indices between the surgical and non-surgical limbs were calculated for GRF and knee kinetic variables. For the stop-jump task, knee kinetics asymmetry indices were correlated with all GRF asymmetry indices (P kinetic asymmetry indices were correlated with the peak propulsion vertical GRF and vertical GRF impulse asymmetry indices (P kinetic asymmetries and therefore may assist in optimizing rehabilitation outcomes and minimizing re-injury rates. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Effect of foot orthoses on magnitude and timing of rearfoot and tibial motions, ground reaction force and knee moment during running.

    Science.gov (United States)

    Eslami, Mansour; Begon, Mickaël; Hinse, Sébastien; Sadeghi, Heydar; Popov, Peter; Allard, Paul

    2009-11-01

    Changes in magnitude and timing of rearfoot eversion and tibial internal rotation by foot orthoses and their contributions to vertical ground reaction force and knee joint moments are not well understood. The objectives of this study were to test if orthoses modify the magnitude and time to peak rearfoot eversion, tibial internal rotation, active ground reaction force and knee adduction moment and determine if rearfoot eversion, tibial internal rotation magnitudes are correlated to peak active ground reaction force and knee adduction moment during the first 60% stance phase of running. Eleven healthy men ran at 170 steps per minute in shod and with foot orthoses conditions. Video and force-plate data were collected simultaneously to calculate foot joint angular displacement, ground reaction forces and knee adduction moments. Results showed that wearing semi-rigid foot orthoses significantly reduced rearfoot eversion 40% (4.1 degrees ; p=0.001) and peak active ground reaction force 6% (0.96N/kg; p=0.008). No significant time differences occurred among the peak rearfoot eversion, tibial internal rotation and peak active ground reaction force in both conditions. A positive and significant correlation was observed between peak knee adduction moment and the magnitude of rearfoot eversion during shod (r=0.59; p=0.04) and shod/orthoses running (r=0.65; p=0.02). In conclusion, foot orthoses could reduce rearfoot eversion so that this can be associated with a reduction of knee adduction moment during the first 60% stance phase of running. Finding implies that modifying rearfoot and tibial motions during running could not be related to a reduction of the ground reaction force.

  9. Estimating patient-specific soft-tissue properties in a TKA knee.

    Science.gov (United States)

    Ewing, Joseph A; Kaufman, Michelle K; Hutter, Erin E; Granger, Jeffrey F; Beal, Matthew D; Piazza, Stephen J; Siston, Robert A

    2016-03-01

    Surgical technique is one factor that has been identified as critical to success of total knee arthroplasty. Researchers have shown that computer simulations can aid in determining how decisions in the operating room generally affect post-operative outcomes. However, to use simulations to make clinically relevant predictions about knee forces and motions for a specific total knee patient, patient-specific models are needed. This study introduces a methodology for estimating knee soft-tissue properties of an individual total knee patient. A custom surgical navigation system and stability device were used to measure the force-displacement relationship of the knee. Soft-tissue properties were estimated using a parameter optimization that matched simulated tibiofemoral kinematics with experimental tibiofemoral kinematics. Simulations using optimized ligament properties had an average root mean square error of 3.5° across all tests while simulations using generic ligament properties taken from literature had an average root mean square error of 8.4°. Specimens showed large variability among ligament properties regardless of similarities in prosthetic component alignment and measured knee laxity. These results demonstrate the importance of soft-tissue properties in determining knee stability, and suggest that to make clinically relevant predictions of post-operative knee motions and forces using computer simulations, patient-specific soft-tissue properties are needed. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. [Clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity].

    Science.gov (United States)

    Chen, Peng; Zeng, Min; Xie, Jie; Wang, Long; Su, Weiping; Hu, Yihe

    2016-09-28

    To investigate the clinical effect of total knee arthroplasty on patients with knee osteoarthritis combined with mild to moderate valgus knee deformity.
 A total of 15 patients received total knee arthroplasty for correcting mild (10°-15°) to moderate (15°-30°) valgus knee between January 2011 and February 2014 in Xiangya Hospital of Central South University. We adopted a stable prosthesis surgery through patellar medial approach, osteophytes cleaning, conventional osteotomy, a selective soft tissue release and balance technical correcting of knee valgus deformity. Then conventional anticoagulation and symptomatic rehabilitation was utilized. Preoperative and postoperative X-ray was conducted in patients with measuring femor-tibial angle (FTA) and inspecting the prosthesis position. FTA, visual analog scale (VAS) standard, and parallel knee scoring system (KSS) were used to evaluate the clinical effect.
 Fifteen patients were followed up for 14 to 36 (22.40±11.88) months. The hospitalization time was 7-13 (7.73±1.58) d; operative time was 58-110 (81.8±16.85) min, the dominant blood loss was 140-600 (337.30±143.65) mL. Two cases had knee extension hysteresis, and the knee activity recovered after exercise. Leg power lines were normal. Three postoperative cases suffered anterior knee pain. They were subjected to celecoxib analgesic treatment and the pain gradually eased after 3 months. One postoperative case showed incision discharge and swelling, which was healed after change of dressing. During follow-up, review of X-ray film does not show prosthesis loose, subsidence and other complications. The knee valgus angle (8.1±1.8)°, knee motion range (107.33±9.61)°, KSS knee score (74.7±14.5, 75.3±2.7) and pain score (2.5±0.9) were significantly better than the preoperative (Pclinical and function KSS scores showed that the improvement rate was 80%. 
 Total knee arthroplasty is an effective way to treat patients with knee osteoarthritis combined with

  11. Influence of Total Knee Arthroplasty on Patellar Kinematics and Patellofemoral Pressure.

    Science.gov (United States)

    Tanikawa, Hidenori; Tada, Mitsunori; Harato, Kengo; Okuma, Kazunari; Nagura, Takeo

    2017-01-01

    Patellofemoral complications are one of the main problems after total knee arthroplasty (TKA). The design of the TKA component may affect the patellar biomechanics, which may be associated with this postoperative complication. The purpose of this study was to assess the influence of TKA and prosthesis designs on the patellar kinematics and patellofemoral pressure. Using fresh-frozen cadavers, we measured the patellofemoral pressure, patella offset, and patella tilt in the following 4 conditions: normal knee (patella replacement only), cruciate-retaining TKA, condylar-stabilizing TKA, and posterior-stabilized TKA. The patellofemoral pressure increased significantly after the cruciate-retaining TKA and condylar-stabilizing TKA compared with the normal knee. The patella offset in the normal knee decreased with increasing knee flexion angles, while the patella offset in the TKA knees did not change significantly through the full range of motion. The amount of lateral patella tilt in the normal knee was significantly larger than the TKA knees in the full range of motion. Although the femoral components are designed to reproduce an anatomical patellar tracking, the physiological patellar kinematics were not observed. Relatively high patellofemoral pressure and kinematic change after TKA may be associated with postoperative complications such as the anterior knee pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Immediate effect of Masai Barefoot Technology shoes on knee joint moments in women with knee osteoarthritis.

    Science.gov (United States)

    Tateuchi, Hiroshige; Taniguchi, Masashi; Takagi, Yui; Goto, Yusuke; Otsuka, Naoki; Koyama, Yumiko; Kobayashi, Masashi; Ichihashi, Noriaki

    2014-01-01

    Footwear modification can beneficially alter knee loading in patients with knee osteoarthritis. This study evaluated the effect of Masai Barefoot Technology shoes on reductions in external knee moments in patients with knee osteoarthritis. Three-dimensional motion analysis was used to examine the effect of Masai Barefoot Technology versus control shoes on the knee adduction and flexion moments in 17 women (mean age, 63.6 years) with radiographically confirmed knee osteoarthritis. The lateral and anterior trunk lean values, knee flexion and adduction angles, and ground reaction force were also evaluated. The influence of the original walking pattern on the changes in knee moments with Masai Barefoot Technology shoes was evaluated. The knee flexion moment in early stance was significantly reduced while walking with the Masai Barefoot Technology shoes (0.25±0.14Nm/kgm) as compared with walking with control shoes (0.30±0.19 Nm/kgm); whereas the knee adduction moment showed no changes. Masai Barefoot Technology shoes did not increase compensatory lateral and anterior trunk lean. The degree of knee flexion moment in the original walking pattern with control shoes was correlated directly with its reduction when wearing Masai Barefoot Technology shoes by multiple linear regression analysis (adjusted R2=0.44, Pknee flexion moment during walking without increasing the compensatory trunk lean and may therefore reduce external knee loading in women with knee osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling.

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J; Martin, James C; Crouter, Scott E; Fitzhugh, Eugene C

    2018-06-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling.

  14. Orthotic intervention in forefoot and rearfoot strike running patterns.

    Science.gov (United States)

    Stackhouse, Carrie Laughton; Davis, Irene McClay; Hamill, Joseph

    2004-01-01

    To compare the differential effect of custom orthoses on the lower extremity mechanics of a forefoot and rearfoot strike pattern. Fifteen subjects ran with both a forefoot and a rearfoot strike pattern with and without orthoses. Lower extremity kinematic and kinetic variables were compared between strike pattern and orthotic conditions. Foot orthoses have been shown to be effective in controlling excessive rearfoot motion in rearfoot strikers. The effect of orthotic intervention on rearfoot motion in forefoot strikers has not been previously reported. Five trials were collected for each condition. Peak rearfoot eversion, eversion excursion, eversion velocity, peak inversion moment, and inversion work were compared between conditions. Kinematic variables in the sagittal plane of the rearfoot and in the frontal and sagittal plane of the knee were also determined. Increased rearfoot excursions and velocities and decreased peak eversion were noted in the forefoot strike pattern compared to the rearfoot strike pattern. Orthotic intervention, however,did not significantly change rearfoot motion in either strike pattern. Reductions in internal rotation and abduction of the knee were noted with orthotic intervention. Foot orthoses do not differentially effect rearfoot motion of a rearfoot strike and a forefoot strike running pattern. Orthotic intervention has a larger and more systematic effect on rearfoot kinetics compared to rearfoot kinematics.

  15. Gender differences in the knee adduction moment after anterior cruciate ligament reconstruction surgery.

    Science.gov (United States)

    Webster, Kate E; McClelland, Jodie A; Palazzolo, Simon E; Santamaria, Luke J; Feller, Julian A

    2012-04-01

    The external knee adduction moment during gait has previously been associated with knee pain and osteoarthritis (OA). Recently, the knee adduction moment has been shown to be increased following anterior cruciate ligament (ACL) reconstruction surgery and has been suggested as a potential mechanism for the progression of early onset knee OA in this population. No study has investigated the gender differences in gait biomechanics following ACL reconstruction. To examine gender differences in gait biomechanics following ACL reconstruction surgery. 36 subjects (18 females, 18 males) who had previously undergone ACL reconstruction surgery (mean time since surgery 20 months) underwent gait analysis at a self-selected walking speed. Males and females were well matched for age, time since surgery and walking speed. Maximum flexion and adduction angles and moments were recorded during the stance phase of level walking and compared between the male and female groups. The knee adduction moment was 23% greater in the female compared with the male ACL group. No gender differences were seen in the sagittal plane. No differences were seen between the reconstructed and contralateral limb. The higher knee adduction moment seen in females compared with males may suggest an increased risk for the development of OA in ACL-reconstructed females.

  16. A kinematic assessment of knee prosthesis from fluoroscopy images

    International Nuclear Information System (INIS)

    Hossain, Mohammad Abrar; Fukunaga, Michihiko; Hirokawa, Shunji

    2008-01-01

    We have developed a technique for estimation 3D motion of knee prosthesis from its 2D perspective projections. Our estimation algorithm includes some innovations such as a two-step estimation algorithm, incorporative use of a geometric articulation model and a new method to solve two silhouettes' overlapping problem. Computer model simulations and experiments results demonstrated that our algorithms give sufficient accuracy. Next, with the cooperation of medical surgeons, we assessed the algorithm's clinical performance by applying it to moving fluoroscopy images of patients who had just undergone total knee arthroplasty (TKA) recently. Our experiments were done in four steps; first we have taken the moving X-ray pictures called fluoroscopy images of the knee prosthesis at different knee motions; second, introduced the absolute positions/orientations for both components, third, introduced the relative positions/orientations between the femoral and the tibial components and finally, introduced the contact points trajectories between the femur and the tibial insert. We drew the estimation results graphically and made the computer-aided detection (CAD) model pictures of the prosthesis, thereby helping us to assess how the relative motions between the femoral and the tibial components were generated. Estimation results of the clinical applications demonstrated that our algorithm worked well as like as theoretical. (author)

  17. Clinical Outcome of Medial Pivot Compared With Press-Fit Condylar Sigma Cruciate-Retaining Mobile-Bearing Total Knee Arthroplasty.

    Science.gov (United States)

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2017-10-01

    The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge

    Science.gov (United States)

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-01-01

    Background: Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. Objectives: In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. Patients and Methods: For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results: Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Conclusion: Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient

  19. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge.

    Science.gov (United States)

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-07-01

    Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient patients during lunge exercise.

  20. Knee and Hip Joint Kinematics Predict Quadriceps and Hamstrings Neuromuscular Activation Patterns in Drop Jump Landings.

    Directory of Open Access Journals (Sweden)

    Bart Malfait

    Full Text Available The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ.Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM,vastus lateralis(VL}, {vastus medialis(VM,hamstring medialis(HM}, {hamstring medialis(HM,hamstring lateralis(HL} and the {vastus lateralis(VL,hamstring lateralis(HL}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping.The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (p<0.05. Small peak knee flexion angles were significantly associated with higher HM amplitudes during the preparatory and initial contact phase (p<0.001. The amplitudes of the {VM,VL} and {VL,HL} were significantly positively associated with the peak hip flexion angle during the peak loading phase (p<0.05. Small peak hip flexion angles were significantly associated with higher VL amplitudes during the peak loading phase (p = 0.001. Higher external knee abduction and flexion moments were found in participants landing with less flexed knee and hip joints (p<0.001.This study demonstrated clear associations between neuromuscular activation patterns and landing kinematics in the sagittal plane during specific parts of the landing. These findings have indicated that an erect landing pattern, characterized by less hip and knee flexion, was significantly associated with an increased medial and posterior

  1. A Passive Dynamic Walking Model Based on Knee-Bend Behaviour: Stability and Adaptability for Walking down Steep Slopes

    Directory of Open Access Journals (Sweden)

    Kang An

    2013-10-01

    Full Text Available This paper presents a passive dynamic walking model based on knee-bend behaviour, which is inspired by the way human beings walk. The length and mass parameters of human beings are used in the walking model. The knee-bend mechanism of the stance leg is designed in the phase between knee-strike and heel-strike. q* which is the angular difference of the stance leg between the two events, knee-strike and knee-bend, is adjusted in order to find a stable walking motion. The results show that the stable periodic walking motion on a slope of r <0.4 can be found by adjusting q*. Furthermore, with a particular q* in the range of 0.12motion is more stable and adaptable than the conventional walking motion, especially for steep slopes.

  2. Early and late synovectomy of the knee in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Jensen, C M; Poulsen, S; Ostergren, M

    1991-01-01

    was reduced and range of motion was unchanged. Total knee alloplasty (TKA) was performed in one knee among the patients who underwent early synovectomy, while reoperation with TKA had been performed in 12 out of 28 knees after late synovectomy. It is concluded that early synovectomy is indicated when medical...... treatment has failed. Late synovectomy must be regarded as a palliative procedure in order to postpone TKA....

  3. Magnetic resonance imaging for the internal derangement of the knee

    International Nuclear Information System (INIS)

    Obara, Noboru; Yamauchi, Kazunori; Ohyama, Naoki; Kura, Hideharu; Tokita, Fumio; Sasaki, Tetsuhito

    1990-01-01

    To assess the usefulness of magnetic resonance imaging (MRI) in the preoperative diagnosis of internal derangement of the knee, MRI findings of 44 knees were reviewed. Definitive diagnoses were made by arthroscopy or arthrotomy: posterior cruciate ligament failure (8 knees), anterior cruciate ligament failure (21), inner meniscus injury (16), and outer meniscus injury (13). T1- and T2-weighted images were obtained by using a 1.5-T superconducting Signa MRI unit. The diagnostic accuracy was 100% for posterior cruciate ligament failure and anterior cruciate ligament failure, 89% for inner meniscus injury, and 93% for outer meniscus injury, suggesting the great potential of MRI in the preoperative diagnosis. For anterior cruciate ligament failure, the diagnostic accuracy was even more increased by combined use of T1-weighted sagittal imaging and T2-weighted coronal imaging. False positive findings for meniscus disorder included rupture of the posterior segment of meniscus, especially in the cnemis end. Longitudinal fissure of the posterior segment of the outer meniscus was misdiagnosed as lacuna of the popliteal muscle tendon. (N.K.)

  4. Conceptualization of an exoskeleton Continuous Passive Motion(CPM) device using a link structure.

    Science.gov (United States)

    Kim, Kyu-Jung; Kang, Min-Sung; Choi, Youn-Sung; Han, Jungsoo; Han, Changsoo

    2011-01-01

    This study is about developing an exoskeleton Continuous Passive Motion (CPM) with the same Range of Motion (ROM) and instant center of rotation as the human knee. The key feature in constructing a CPM is an accurate alignment with the human knee joint enabling it to deliver the same movements as the actual body on the CPM. In this research, we proposed an exoskeleton knee joint through kinematic interpretation, measured the knee joint torque generated while using a CPM and applied it to the device. Thus, this new exoskeleton type CPM will allow precise alignment with the human knee joint, and follow the same ROM as the human knee in any position. © 2011 IEEE

  5. Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty.

    Science.gov (United States)

    Inui, Hiroshi; Taketomi, Shuji; Yamagami, Ryota; Sanada, Takaki; Tanaka, Sakae

    2016-01-01

    Bone cutting error can be one of the causes of malalignment in unicompartmental knee arthroplasty (UKA). The amount of cutting error in total knee arthroplasty has been reported. However, none have investigated cutting error in UKA. The purpose of this study was to reveal the amount of cutting error in UKA when open cutting guide was used and clarify whether cutting the tibia horizontally twice using the same cutting guide reduced the cutting errors in UKA. We measured the alignment of the tibial cutting guides, the first-cut cutting surfaces and the second cut cutting surfaces using the navigation system in 50 UKAs. Cutting error was defined as the angular difference between the cutting guide and cutting surface. The mean absolute first-cut cutting error was 1.9° (1.1° varus) in the coronal plane and 1.1° (0.6° anterior slope) in the sagittal plane, whereas the mean absolute second-cut cutting error was 1.1° (0.6° varus) in the coronal plane and 1.1° (0.4° anterior slope) in the sagittal plane. Cutting the tibia horizontally twice reduced the cutting errors in the coronal plane significantly (Pcutting the tibia horizontally twice using the same cutting guide reduced cutting error in the coronal plane. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. The use of synthetic ligaments in the design of an enhanced stability total knee joint replacement.

    Science.gov (United States)

    Stokes, Michael D; Greene, Brendan C; Pietrykowski, Luke W; Gambon, Taylor M; Bales, Caroline E; DesJardins, John D

    2018-03-01

    Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.

  7. Accuracy of Implant Placement Utilizing Customized Patient Instrumentation in Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    William D. Bugbee

    2013-01-01

    Full Text Available Customized patient instrumentation (CPI combines preoperative planning with customized cutting jigs to position and align implants during total knee arthroplasty (TKA. We compared postoperative implant alignment of patients undergoing surgery with CPI to traditional TKA instrumentation for accuracy of implant placement. Twenty-five consecutive TKAs using CPI were analyzed. Preoperative CT scans of the lower extremities were segmented using a computer program. Limb alignment and mechanical axis were computed. Virtual implantation of computer-aided design models was done. Postoperative coronal and sagittal view radiographs were obtained. Using 3D image-matching software, relative positions of femoral and tibial implants were determined. Twenty-five TKAs implanted using traditional instrumentation were also analyzed. For CPI, difference in alignment from the preoperative plan was calculated. In the CPI group, the mean absolute difference between the planned and actual femoral placements was 0.67° in the coronal plane and 1.2° in the sagittal plane. For tibial alignment, the mean absolute difference was 0.9° in the coronal plane and 1.3° in the sagittal plane. For traditional instrumentation, difference from ideal placement for the femur was 1.5° in the coronal plane and 2.3° in the sagittal plane. For the tibia, the difference was 1.8° in the coronal plane. CPI achieved accurate implant positioning and was superior to traditional TKA instrumentation.

  8. Knee joint anterior malalignment and patellofemoral osteoarthritis: an MRI study

    International Nuclear Information System (INIS)

    Tsavalas, Nikolaos; Karantanas, Apostolos H.; Katonis, Pavlos

    2012-01-01

    To evaluate patellofemoral congruency measurements on MRI and correlate the findings with severity of ipsilateral osteoarthritis. We retrospectively reviewed 650 consecutive knee MRI examinations from 622 patients divided into two age groups: ≤50 and >50 year-old. The femoral sulcus angle (SA) and depth (SD), lateral patellar displacement (LPD), lateral patellofemoral angle (LPFA), tibial tubercle-trochlear groove (TT-TG) distance and Insall-Salvati index as well as the grade of focal cartilage defects (ranging from I to IV) in the patellofemoral region were assessed in each subject on axial and sagittal fat-saturated intermediate-w MR images. A significant difference exists between normal and knees with patellofemoral joint osteoarthritis regarding SA (p = 0.0002 and 50 respectively). Significant correlation was found between grading of cartilage defects and SA (rho = 0.21, p = 0.0001 and 0.443, <0.0001), SD (rho = -0.198, p = 0.0003 and -0.418, <0.0001), LPD (rho = 0.176, p = 0.0013 and 0.251, 0.0002) and LPFA (rho = -0.204, p = 0.0002 and -0.239, 0.0005) in both age groups. Knee joint anterior malalignment is multivariably associated with patellofemoral osteoarthritis. circle MRI is an excellent method to evaluate knee alignment and articular cartilage damage. (orig.)

  9. Anteroposterior glide versus rotating platform low contact stress (LCS knee arthroplasty: a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Wynn-Jones Charles

    2007-08-01

    Full Text Available Abstract Background Fifty thousand knee replacements are performed annually in the UK at an estimated cost of £150 million. Post-operative improvement depends on a number of factors including implant design and patient associated factors. To our knowledge there are no published study's comparing the results of AP glide and rotating platform designs of LCS knee arthroplasty. Therefore we feel that a study is required to investigate and compare the effects of two types of LCS total knee arthroplasty on joint proprioception and range of motion. Methods/Design Patients will be randomised to receive either a LCS AP glide or Rotating platform prosthesis. Clinical scores (Oxford knee score, American knee society score, EuroQol, range of motion and proprioception will be assessed prior to and at 3,6, 12 and 24 months after the operation. Proprioception will be assessed in terms of absolute error angle (mean difference between the target angle and the response angle. Knee angles will be measured in degrees using an electromagnetic tracking device, Polhemus 3Space Fastrak that detects positions of sensors placed on the test limb. Student's t-test will be used to compare the mean of two groups. Discussion Evidence is lacking concerning the best prosthesis to use for patients undergoing total knee replacement. This pragmatic randomised trial will test the null hypothesis that anteroposterior glide LCS knee arthroplasty does not result in better post operative knee motion and proprioception as compared to rotating platform LCS knee. Trial Registration ISRCTN52943804

  10. Effects of Knee Alignments and Toe Clip on Frontal Plane Knee Biomechanics in Cycling

    Science.gov (United States)

    Shen, Guangping; Zhang, Songning; Bennett, Hunter J.; Martin, James C.; Crouter, Scott E.; Fitzhugh, Eugene C.

    2018-01-01

    Effects of knee alignment on the internal knee abduction moment (KAM) in walking have been widely studied. The KAM is closely associated with the development of medial knee osteoarthritis. Despite the importance of knee alignment, no studies have explored its effects on knee frontal plane biomechanics during stationary cycling. The purpose of this study was to examine the effects of knee alignment and use of a toe clip on the knee frontal plane biomechanics during stationary cycling. A total of 32 participants (11 varus, 11 neutral, and 10 valgus alignment) performed five trials in each of six cycling conditions: pedaling at 80 rpm and 0.5 kg (40 Watts), 1.0 kg (78 Watts), and 1.5 kg (117 Watts) with and without a toe clip. A motion analysis system and a customized instrumented pedal were used to collect 3D kinematic and kinetic data. A 3 × 2 × 3 (group × toe clip × workload) mixed design ANOVA was used for statistical analysis (p < 0.05). There were two different knee frontal plane loading patterns, internal abduction and adduction moment, which were affected by knee alignment type. The knee adduction angle was 12.2° greater in the varus group compared to the valgus group (p = 0.001), yet no difference was found for KAM among groups. Wearing a toe clip increased the knee adduction angle by 0.95º (p = 0.005). The findings of this study indicate that stationary cycling may be a safe exercise prescription for people with knee malalignments. In addition, using a toe clip may not have any negative effects on knee joints during stationary cycling. Key points Varus or valgus alignment did not cause increased frontal-plane knee joint loading, suggesting stationary cycling is a safe exercise. This study supports that using a toe clip did not lead to abnormal frontal-plane knee loading during stationary cycling. Two different knee frontal plane loading patterns, knee abduction and adduction moment, were observed during stationary cycling, which are likely affected by

  11. Does shoe heel design influence ground reaction forces and knee moments during maximum lunges in elite and intermediate badminton players?

    Directory of Open Access Journals (Sweden)

    Wing-Kai Lam

    Full Text Available Lunge is one frequently executed movement in badminton and involves a unique sagittal footstrike angle of more than 40 degrees at initial ground contact compared with other manoeuvres. This study examined if the shoe heel curvature design of a badminton shoe would influence shoe-ground kinematics, ground reaction forces, and knee moments during lunge.Eleven elite and fifteen intermediate players performed five left-forward maximum lunge trials with Rounded Heel Shoe (RHS, Flattened Heel Shoe (FHS, and Standard Heel Shoes (SHS. Shoe-ground kinematics, ground reaction forces, and knee moments were measured by using synchronized force platform and motion analysis system. A 2 (Group x 3 (Shoe ANOVA with repeated measures was performed to determine the effects of different shoes and different playing levels, as well as the interaction of two factors on all variables.Shoe effect indicated that players demonstrated lower maximum vertical loading rate in RHS than the other two shoes (P < 0.05. Group effect revealed that elite players exhibited larger footstrike angle, faster approaching speed, lower peak horizontal force and horizontal loading rates but higher vertical loading rates and larger peak knee flexion and extension moments (P < 0.05. Analysis of Interactions of Group x Shoe for maximum and mean vertical loading rates (P < 0.05 indicated that elite players exhibited lower left maximum and mean vertical loading rates in RHS compared to FHS (P < 0.01, while the intermediate group did not show any Shoe effect on vertical loading rates.These findings indicate that shoe heel curvature would play some role in altering ground reaction force impact during badminton lunge. The differences in impact loads and knee moments between elite and intermediate players may be useful in optimizing footwear design and training strategy to minimize the potential risks for impact related injuries in badminton.

  12. Postural Consequences of Cervical Sagittal Imbalance: A Novel Laboratory Model.

    Science.gov (United States)

    Patwardhan, Avinash G; Havey, Robert M; Khayatzadeh, Saeed; Muriuki, Muturi G; Voronov, Leonard I; Carandang, Gerard; Nguyen, Ngoc-Lam; Ghanayem, Alexander J; Schuit, Dale; Patel, Alpesh A; Smith, Zachary A; Sears, William

    2015-06-01

    A biomechanical study using human spine specimens. To study postural compensations in lordosis angles that are necessary to maintain horizontal gaze in the presence of forward head posture and increasing T1 sagittal tilt. Forward head posture relative to the shoulders, assessed radiographically using the horizontal offset distance between the C2 and C7 vertebral bodies (C2-C7 [sagittal vertical alignment] SVA), is a measure of global cervical imbalance. This may result from kyphotic alignment of cervical segments, muscle imbalance, as well as malalignment of thoracolumbar spine. Ten cadaveric cervical spines (occiput-T1) were tested. The T1 vertebra was anchored to a tilting and translating base. The occiput was free to move vertically but its angular orientation was constrained to ensure horizontal gaze regardless of sagittal imbalance. A 5-kg mass was attached to the occiput to mimic head weight. Forward head posture magnitude and T1 tilt were varied and motions of individual vertebrae were measured to calculate C2-C7 SVA and lordosis across C0-C2 and C2-C7. Increasing C2-C7 SVA caused flexion of lower cervical (C2-C7) segments and hyperextension of suboccipital (C0-C1-C2) segments to maintain horizontal gaze. Increasing kyphotic T1 tilt primarily increased lordosis across the C2-C7 segments. Regression models were developed to predict the compensatory C0-C2 and C2-C7 angulation needed to maintain horizontal gaze given values of C2-C7 SVA and T1 tilt. This study established predictive relationships between radiographical measures of forward head posture, T1 tilt, and postural compensations in the cervical lordosis angles needed to maintain horizontal gaze. The laboratory model predicted that normalization of C2-C7 SVA will reduce suboccipital (C0-C2) hyperextension, whereas T1 tilt reduction will reduce the hyperextension in the C2-C7 segments. The predictive relationships may help in planning corrective strategy in patients experiencing neck pain, which may be

  13. Improved kinect-based spatiotemporal and kinematic treadmill gait assessment.

    Science.gov (United States)

    Eltoukhy, Moataz; Oh, Jeonghoon; Kuenze, Christopher; Signorile, Joseph

    2017-01-01

    A cost-effective, clinician friendly gait assessment tool that can automatically track patients' anatomical landmarks can provide practitioners with important information that is useful in prescribing rehabilitative and preventive therapies. This study investigated the validity and reliability of the Microsoft Kinect v2 as a potential inexpensive gait analysis tool. Ten healthy subjects walked on a treadmill at 1.3 and 1.6m·s -1 , as spatiotemporal parameters and kinematics were extracted concurrently using the Kinect and three-dimensional motion analysis. Spatiotemporal measures included step length and width, step and stride times, vertical and mediolateral pelvis motion, and foot swing velocity. Kinematic outcomes included hip, knee, and ankle joint angles in the sagittal plane. The absolute agreement and relative consistency between the two systems were assessed using interclass correlations coefficients (ICC2,1), while reproducibility between systems was established using Lin's Concordance Correlation Coefficient (rc). Comparison of ensemble curves and associated 90% confidence intervals (CI90) of the hip, knee, and ankle joint angles were performed to investigate if the Kinect sensor could consistently and accurately assess lower extremity joint motion throughout the gait cycle. Results showed that the Kinect v2 sensor has the potential to be an effective clinical assessment tool for sagittal plane knee and hip joint kinematics, as well as some spatiotemporal temporal variables including pelvis displacement and step characteristics during the gait cycle. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Satisfactory knee function after single-stage posterolateral corner reconstruction in the multi-ligament injured/dislocated knee using the anatomic single-graft technique.

    Science.gov (United States)

    Sanders, Thomas L; Johnson, Nick R; Pareek, Ayoosh; Krych, Aaron J; Marx, Robert G; Stuart, Michael J; Levy, Bruce A

    2018-04-01

    Increasing importance has been placed on the posterolateral corner (PLC) in maintaining varus and rotational stability of the knee. The goal of this study was to evaluate knee function and clinical stability following a single-graft PLC reconstruction technique and identify factors associated with poor knee function. This study identified patients with a multi-ligament knee injury between 2006 and 2013. Patients who received a single-graft fibular collateral ligament and PLC reconstruction with a single-stage surgery during the study period and had a minimum follow-up of 2 years after surgery were included. Functional outcomes were assessed using Lysholm and IKDC scores. Varus and rotational knee laxity and range of motion were assessed using physical examination. The final study cohort included 61 patients who underwent PLC reconstruction using a single-graft technique. The mean IKDC score was 74.1 (± 22.3) and the mean Lysholm score was 80.3 (± 21.8) at mean follow-up of 3.8 years (range 2-9 years). Mean range of motion at final follow-up measured from 0° to 126° [range flexion: 95-145, range extension: 0-5]. Fifty-eight patients (95%) had grade 0 varus laxity in full knee extension, and 54 patients (88.5%) had grade 0 varus laxity at 30° of knee flexion. Female gender was associated with a lower postoperative IKDC score (p = 0.04). Surgical treatment of the PLC using a single-graft technique can result in satisfactory knee function and stable physical examination findings at minimum 2 years after surgery. Female gender was predictive of poor knee function after PLC reconstruction. Surgical treatment of PLC injuries should be individualized based on the timing of surgery, specific injured knee structures, and physical examination findings. This study helps validate the use of a single-graft technique for PLC reconstruction and can be used to help counsel patients about expected knee function after surgical treatment of PLC injuries. Level of evidence

  15. Dynamic knee stability and ballistic knee movement after ACL reconstruction: an application on instep soccer kick.

    Science.gov (United States)

    Cordeiro, Nuno; Cortes, Nelson; Fernandes, Orlando; Diniz, Ana; Pezarat-Correia, Pedro

    2015-04-01

    The instep soccer kick is a pre-programmed ballistic movement with a typical agonist-antagonist coordination pattern. The coordination pattern of the kick can provide insight into deficient neuromuscular control. The purpose of this study was to investigate knee kinematics and hamstrings/quadriceps coordination pattern during the knee ballistic extension phase of the instep kick in soccer players after anterior cruciate ligament reconstruction (ACL reconstruction). Seventeen players from the Portuguese Soccer League participated in this study. Eight ACL-reconstructed athletes (experimental group) and 9 healthy individuals (control group) performed three instep kicks. Knee kinematics (flexion and extension angles at football contact and maximum velocity instants) were calculated during the kicks. Rectus femoris (RF), vastus lateralis, vastus medialis, biceps femoralis, and semitendinosus muscle activations were quantified during the knee extension phase. The ACL-reconstructed group had significantly lower knee extension angle (-1.2 ± 1.6, p ballistic control movement pattern between normal and ACL-reconstructed subjects. Performing open kinetic chain exercises using ballistic movements can be beneficial when recovering from ACL reconstruction. The exercises should focus on achieving multi-joint coordination and full knee extension (range of motion). III.

  16. Audiovisual biofeedback improves the correlation between internal/external surrogate motion and lung tumor motion.

    Science.gov (United States)

    Lee, Danny; Greer, Peter B; Paganelli, Chiara; Ludbrook, Joanna Jane; Kim, Taeho; Keall, Paul

    2018-03-01

    Breathing management can reduce breath-to-breath (intrafraction) and day-by-day (interfraction) variability in breathing motion while utilizing the respiratory motion of internal and external surrogates for respiratory guidance. Audiovisual (AV) biofeedback, an interactive personalized breathing motion management system, has been developed to improve reproducibility of intra- and interfraction breathing motion. However, the assumption of the correlation of respiratory motion between surrogates and tumors is not always verified during medical imaging and radiation treatment. Therefore, the aim of the study was to test the hypothesis that the correlation of respiratory motion between surrogates and tumors is the same under free breathing without guidance (FB) and with AV biofeedback guidance for voluntary motion management. For 13 lung cancer patients receiving radiotherapy, 2D coronal and sagittal cine-MR images were acquired across two MRI sessions (pre- and mid-treatment) with two breathing conditions: (a) FB and (b) AV biofeedback, totaling 88 patient measurements. Simultaneously, the external respiratory motion of the abdomen was measured. The internal respiratory motion of the diaphragm and lung tumor was retrospectively measured from 2D coronal and sagittal cine-MR images. The correlation of respiratory motion between surrogates and tumors was calculated using Pearson's correlation coefficient for: (a) abdomen to tumor (abdomen-tumor) and (b) diaphragm to tumor (diaphragm-tumor). The correlations were compared between FB and AV biofeedback using several metrics: abdomen-tumor and diaphragm-tumor correlations with/without ≥5 mm tumor motion range and with/without adjusting for phase shifts between the signals. Compared to FB, AV biofeedback improved abdomen-tumor correlation by 11% (p = 0.12) from 0.53 to 0.59 and diaphragm-tumor correlation by 13% (p = 0.02) from 0.55 to 0.62. Compared to FB, AV biofeedback improved abdomen-tumor correlation by 17% (p = 0

  17. Three-Dimensional Scapular Kinematics in Patients with Reverse Total Shoulder Arthroplasty during Arm Motion.

    Science.gov (United States)

    Lee, Kwang Won; Kim, Yong In; Kim, Ha Yong; Yang, Dae Suk; Lee, Gyu Sang; Choy, Won Sik

    2016-09-01

    There have been few reports on altered kinematics of the shoulder after reverse total shoulder arthroplasty (RTSA). We investigated differences in 3-dimensional (3D) scapular motions assessed using an optical tracking system between RTSA treated shoulders and asymptomatic contralateral shoulders during arm motion. Thirteen patients who underwent RTSA were assessed for active arm elevation in 2 distinct elevation planes (sagittal plane flexion and scapular plane abduction). Their mean age was 72 years (range, 69 to 79 years) and the mean follow-up was 24.4 months (range, 13 to 48 months). The dominant side was the right side in all the 13 patients, and it was also the side treated with RTSA. Scapular kinematics was recorded with an optical tracking system. The scapular kinematics and the scapulohumeral rhythm (SHR) of the RTSA shoulders and asymptomatic contralateral shoulders were recorded and analyzed during arm elevation. There were no significant differences in internal/external rotation and anterior/posterior tilting of the scapula between shoulders during arm motion (p > 0.05). However, upward rotation of the scapula differed significantly during arm motion (p = 0.035 for sagittal plane flexion; p = 0.046 for scapular plane abduction). There were significant differences in the SHR between the two shoulders (p = 0.016 for sagittal plane flexion; p = 0.021 for scapular plane abduction). The shoulder kinematics after RTSA showed significant differences from the contralateral asymptomatic shoulders. Increased upward rotation and decreased SHR after RTSA indicate that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm.

  18. Discoid meniscus of the knee: MR imaging

    International Nuclear Information System (INIS)

    Kim, Sung Moon; Kang, Heung Sik; Ahn, Joong Mo; Seong, Sang Cheol

    1992-01-01

    To evaluate the role of magnetic resonance (MR) imaging in the diagnosis of the discoid meniscus, the authors reviewed 31 cases of discoid menisci diagnosed by MR imaging among which 16 cases received arthroscopy. Using knee surface coil, sagittal T1, T2 and proton density images and coronal T1 weighted images were obtained with 18 cm FOV and 4 mm/ 1 mm thickness/gap. A discoid meniscus was considered if three or more contiguous sagittal images demonstrated continuity of the meniscus between the anterior and posterior horns or the diameter of the mid-portion of the meniscus exceeded 15 mm on the coronal image. The authors also observed the associated abnormalities including tears of meniscus and ligament, meniscal cyst, and osteochondral defects. All discoid menisci were lateral menisci and torn discoid lateral menisci were present in 26 cases (83%). In two cases, tears of the contralateral medial meniscus were present. The tears of anterior and posterior cruciate ligaments, meniscal cyst, and osteochondral defects were present in 4, 2, 4, and 5 cases respectively. All collateral ligaments were intact. In conclusion MR imaging was useful for the detection of discoid meniscus and associated abnormalities

  19. Joint angles of the ankle, knee, and hip and loading conditions during split squats.

    Science.gov (United States)

    Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio

    2014-06-01

    The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.

  20. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    Science.gov (United States)

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  1. Relationships among spinal mobility and sagittal alignment of spine and lower extremity to quality of life and risk of falls.

    Science.gov (United States)

    Ishikawa, Yoshinori; Miyakoshi, Naohisa; Hongo, Michio; Kasukawa, Yuji; Kudo, Daisuke; Shimada, Yoichi

    2017-03-01

    Spinal deformities can affect quality of life (QOL) and risk of falling, but no studies have explored the relationships of spinal mobility and sagittal alignment of spine and the lower extremities simultaneously. Purpose of this study is to clarify the relationship of those postural parameters to QOL and risk of falling. The study evaluated 110 subjects (41 men, 69 women; mean age, 73 years). Upright and flexion and extension angles for thoracic kyphosis, lumbar lordosis, and spinal inclination were evaluated with SpinalMouse ® . Total-body inclination and hip and knee flexion angles in upright position were measured from lateral photographs. Subjects were divided into Fallers (n=23, 21%) and Non-fallers (n=87, 79%) based on past history of falls. QOL was assessed using the Short Form 36 Health Survey (SF-36 ® ). Age, total-body inclination, spinal inclination upright and in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and knee flexion correlated significantly with the SF-36. Multiple regression analysis revealed total-body inclination and knee flexion to have the most significant relationships with the SF-36. SF-36, total-body inclination, spinal inclination in extension, thoracic kyphosis in flexion, lumbar lordosis upright and in extension, and hip and knee flexion angles differed significantly between Fallers and Non-fallers (Pfalling (P=0.038). Forward-stooped posture and knee-flexion deformity could be important indicator of lower QOL. Moreover, limited extension in the lumbar spine could be a useful screening examination for fall prevention in the elderly. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Gait Parameters and Functional Outcomes After Total Knee Arthroplasty Using Persona Knee System With Cruciate Retaining and Ultracongruent Knee Inserts.

    Science.gov (United States)

    Rajgopal, Ashok; Aggarwal, Kalpana; Khurana, Anshika; Rao, Arun; Vasdev, Attique; Pandit, Hemant

    2017-01-01

    Total knee arthroplasty is a well-established treatment for managing end-stage symptomatic knee osteoarthritis. Currently, different designs of prostheses are available with majority ensuring similar clinical outcomes. Altered surface geometry is introduced to strive toward gaining superior outcomes. We aimed to investigate any differences in functional outcomes between 2 different polyethylene designs namely the Persona CR (cruciate retaining) and Persona UC (ultracongruent) tibial inserts (Zimmer-Biomet, Warsaw, IN). This prospective single blind, single-surgeon randomized controlled trial reports on 105 patients, (66 female and 39 male), who underwent simultaneous bilateral total knee arthroplasty using the Persona knee system (Zimmer-Biomet) UC inserts in one side and CR inserts in the contralateral side. By a blind assessor, at regular time intervals patients were assessed in terms of function and gait. The functional knee scoring scales used were the Western Ontario and McMaster Universities Osteoarthritis Index and Modified Knee Society Score. The gait parameters evaluated were foot pressure and step length. During the study period, no patient was lost to follow-up or underwent revision surgery for any cause. Western Ontario and McMaster Universities Osteoarthritis Index scores, Modified Knee Society Score, and knee range of motion of all 105 patients assessed preoperatively and postoperatively at 6 months, 1 year, and 2 years showed statistically better results (P < .05) for UC inserts. Gait analysis measuring foot pressures and step length, however, did not show any statistically significant differences at 2-year follow-up. Ultracongruent tibial inserts show significantly better functional outcomes as compared to CR inserts during a 2-year follow-up period. However, in this study these findings were not shown to be attributed to differences in gait parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Does rehabilitation of cervical lordosis influence sagittal cervical spine flexion extension kinematics in cervical spondylotic radiculopathy subjects?

    Science.gov (United States)

    Moustafa, Ibrahim Moustafa; Diab, Aliaa Attiah Mohamed; Hegazy, Fatma A; Harrison, Deed E

    2017-01-01

    To test the hypothesis that improvement of cervical lordosis in cervical spondylotic radiculopathy (CSR) will improve cervical spine flexion and extension end range of motion kinematics in a population suffering from CSR. Thirty chronic lower CSR patients with cervical lordosis lordosis (p lordosis in the study group was associated with significant improvement in the translational and rotational motions of the lower cervical spine. This finding provides objective evidence that cervical flexion/extension is partially dependent on the posture and sagittal curve orientation. These findings are in agreement with several other reports in the literature; whereas ours is the first post treatment analysis identifying this relationship.

  4. The effect of a knee ankle foot orthosis incorporating an active knee mechanism on gait of a person with poliomyelitis.

    Science.gov (United States)

    Arazpour, Mokhtar; Chitsazan, Ahmad; Bani, Monireh Ahmadi; Rouhi, Gholamreza; Ghomshe, Farhad Tabatabai; Hutchins, Stephen W

    2013-10-01

    The aim of this case study was to identify the effect of a powered stance control knee ankle foot orthosis on the kinematics and temporospatial parameters of walking by a person with poliomyelitis when compared to a knee ankle foot orthosis. A knee ankle foot orthosis was initially manufactured by incorporating drop lock knee joints and custom molded ankle foot orthoses and fitted to a person with poliomyelitis. The orthosis was then adapted by adding electrically activated powered knee joints to provide knee extension torque during stance and also flexion torque in swing phase. Lower limb kinematic and kinetic data plus data for temporospatial parameters were acquired from three test walks using each orthosis. Walking speed, step length, and vertical and horizontal displacement of the pelvis decreased when walking with the powered stance control knee ankle foot orthosis compared to the knee ankle foot orthosis. When using the powered stance control knee ankle foot orthosis, the knee flexion achieved during swing and also the overall pattern of walking more closely matched that of normal human walking. The reduced walking speed may have caused the smaller compensatory motions detected when the powered stance control knee ankle foot orthosis was used. The new powered SCKAFO facilitated controlled knee flexion and extension during ambulation for a volunteer poliomyelitis person.

  5. Diagnostic performance of in vivo 3-T MRI for articular cartilage abnormalities in human osteoarthritic knees using histology as standard of reference

    International Nuclear Information System (INIS)

    Saadat, Ehsan; Jobke, Bjoern; Chu, Bill; Lu, Ying; Cheng, Jonathan; Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M.; Ries, Michael D.

    2008-01-01

    The purpose of this study was (1) to evaluate the sensitivity, specificity and accuracy of sagittal in vivo 3-T intermediate-weighted fast spin-echo (iwFSE) sequences in the assessment of knee cartilage pathologies using histology as the reference standard in patients undergoing total knee replacement, and (2) to correlate MR imaging findings typically associated with osteoarthritis such as bone marrow edema pattern (BMEP) and cartilage swelling with histological findings. Tibial plateaus and femoral condyles of eight knees of seven patients were resected during surgery, and sagittal histological sections were prepared for histology. Preoperative MRI findings were compared to the corresponding region in histological sections for thickness, surface integrity and signal pattern of cartilage, and histological findings in areas of BMEP and swelling were documented. The overall sensitivity, specificity and accuracy were 72%, 69% and 70% for thickness, 69%, 74% and 73% for surface and 36%, 62% and 45% for intracartilaginous signal pattern. For all cases of BMEP on MRI subchondral ingrowth of fibrovascular tissue and increased bone remodeling were observed. MRI using fat-saturated iwFSE sequences showed good performance in assessing cartilage thickness and surface lesions, while signal changes of cartilage were not suited to characterize the severity of cartilage degeneration as validated by histology. (orig.)

  6. Diagnostic performance of in vivo 3-T MRI for articular cartilage abnormalities in human osteoarthritic knees using histology as standard of reference

    Energy Technology Data Exchange (ETDEWEB)

    Saadat, Ehsan [University of California San Francisco, School of Medicine and Department of Radiology, San Francisco, CA (United States); Jobke, Bjoern; Chu, Bill; Lu, Ying; Cheng, Jonathan; Li, Xiaojuan; Majumdar, Sharmila; Link, Thomas M. [University of California San Francisco, Department of Radiology, San Francisco, CA (United States); Ries, Michael D. [University of California San Francisco, Department of Orthopaedic Surgery, San Francisco, CA (United States)

    2008-10-15

    The purpose of this study was (1) to evaluate the sensitivity, specificity and accuracy of sagittal in vivo 3-T intermediate-weighted fast spin-echo (iwFSE) sequences in the assessment of knee cartilage pathologies using histology as the reference standard in patients undergoing total knee replacement, and (2) to correlate MR imaging findings typically associated with osteoarthritis such as bone marrow edema pattern (BMEP) and cartilage swelling with histological findings. Tibial plateaus and femoral condyles of eight knees of seven patients were resected during surgery, and sagittal histological sections were prepared for histology. Preoperative MRI findings were compared to the corresponding region in histological sections for thickness, surface integrity and signal pattern of cartilage, and histological findings in areas of BMEP and swelling were documented. The overall sensitivity, specificity and accuracy were 72%, 69% and 70% for thickness, 69%, 74% and 73% for surface and 36%, 62% and 45% for intracartilaginous signal pattern. For all cases of BMEP on MRI subchondral ingrowth of fibrovascular tissue and increased bone remodeling were observed. MRI using fat-saturated iwFSE sequences showed good performance in assessing cartilage thickness and surface lesions, while signal changes of cartilage were not suited to characterize the severity of cartilage degeneration as validated by histology. (orig.)

  7. Magnetic resonance imaging of anterior cruciate ligament of the knee: a comparison of four sequences

    International Nuclear Information System (INIS)

    Casillas, C.; Marti-Bonmati, L.; Molla, E.; Ferrer, P.; Dosda, R.

    1999-01-01

    To compare the diagnostic efficacy of the four magnetic resonance imaging (MRI) sequences that compose the standard protocol for the study of the knee in our center when employed in the examination of anterior cruciate ligament (ACL). A prospective study was carried out based on MRI findings in the knees of 326 consecutive patients. Sagittal [proton density (PD w eighted turbo-spin-echo and T2*-weighted gradient echo], coronal (PD-weighted turbo-spin-echo with fat suppression) and transverse (T2*-weighted gradient echo with magnetization transfer) images were evaluated. Each sequence was analyzed independently by two radiologists, while another two assessed all the sequences together with the clinical findings. Four categories were established: normal ACL, partially torn, completely torn and synovialized. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) with respect to the definitive diagnosis were calculated for each sequence. The statistical analysis of the findings for each category was done using the chi-squared test and the Kappa test was employed to assess the degree of agreement. According to the final diagnosis, 263 ACL were normal, 29 were partially torn, 33 were completely torn and there was 1 case of synovialization associated with a completely torn ACL. The relationship between the analysis of the ACL according to each sequence and the definitive diagnosis was very significant (p<0.001) and the agreement was excellent. All the sequences presented similar levels of diagnostic precision. The coronal sequence had least number of diagnostic errors (2.1%). The combinations of imaging techniques that resulted in the lowest error rate with respect to the definitive diagnosis were coronal PD-weighted turbo-spin-echo with fat suppression and sagittal PD-weighted turbo-spin-echo. Coronal images are highly precise in the evaluation of ACL. Sagittal sequences are the most valid for diagnosis of torn ACL. Transverse

  8. Modelling and Analysis on Biomechanical Dynamic Characteristics of Knee Flexion Movement under Squatting

    Directory of Open Access Journals (Sweden)

    Jianping Wang

    2014-01-01

    Full Text Available The model of three-dimensional (3D geometric knee was built, which included femoral-tibial, patellofemoral articulations and the bone and soft tissues. Dynamic finite element (FE model of knee was developed to simulate both the kinematics and the internal stresses during knee flexion. The biomechanical experimental system of knee was built to simulate knee squatting using cadaver knees. The flexion motion and dynamic contact characteristics of knee were analyzed, and verified by comparing with the data from in vitro experiment. The results showed that the established dynamic FE models of knee are capable of predicting kinematics and the contact stresses during flexion, and could be an efficient tool for the analysis of total knee replacement (TKR and knee prosthesis design.

  9. The usefulness of sagittal reformation for diagnosis of sternal fracture

    Energy Technology Data Exchange (ETDEWEB)

    Im, Dong Jin; Hahn, Seok; Kim, Young Ju [Dept. of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2014-01-15

    The purpose of our study was to evaluate the usefulness of sagittal reformation of chest computed tomography for the diagnosis of sternal fracture after trauma. We retrospectively reviewed medical records and chest computer tomography (CT) of 716 patients in the emergency department after trauma between January and December 2010. Two radiologists investigated chest CT images. We investigated numbers and locations of sternal fractures on axial images only and on both axial and sagittal images for each radiologist. First, radiologist found sternal fractures in 58 patients (70.7%) on only axial images, and 80 (97.5%) on both axial and sagittal images. Second, radiologist found fractures in 67 patients (81.7%) on axial image only and 81 (98.7%) on both axial and sagittal images. The sensitivity increased after adding sagittal reformation images for each radiologist (p < 0.05, respectively). On the axial images, the interobserver agreement was low (k 0.596) between the two radiologists. However, on both axial and sagittal images, the interobserver agreement increased (k = 0.872). Sagittal reformation of chest CT increases the chance of diagnosis for sternal fracture and leads to early diagnosis resulting in appropriate treatment.

  10. The usefulness of sagittal reformation for diagnosis of sternal fracture

    International Nuclear Information System (INIS)

    Im, Dong Jin; Hahn, Seok; Kim, Young Ju

    2014-01-01

    The purpose of our study was to evaluate the usefulness of sagittal reformation of chest computed tomography for the diagnosis of sternal fracture after trauma. We retrospectively reviewed medical records and chest computer tomography (CT) of 716 patients in the emergency department after trauma between January and December 2010. Two radiologists investigated chest CT images. We investigated numbers and locations of sternal fractures on axial images only and on both axial and sagittal images for each radiologist. First, radiologist found sternal fractures in 58 patients (70.7%) on only axial images, and 80 (97.5%) on both axial and sagittal images. Second, radiologist found fractures in 67 patients (81.7%) on axial image only and 81 (98.7%) on both axial and sagittal images. The sensitivity increased after adding sagittal reformation images for each radiologist (p < 0.05, respectively). On the axial images, the interobserver agreement was low (k 0.596) between the two radiologists. However, on both axial and sagittal images, the interobserver agreement increased (k = 0.872). Sagittal reformation of chest CT increases the chance of diagnosis for sternal fracture and leads to early diagnosis resulting in appropriate treatment.

  11. Design and Evaluation of a New Type of Knee Orthosis to Align the Mediolateral Angle of the Knee Joint with Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Amir Esrafilian

    2012-01-01

    Full Text Available Background. Osteoarthritis (OA is a disease which influences the performance of the knee joint. Moreover, the force and moments applied on the joint increase in contrast to normal subjects. Various types of knee orthoses have been designed to solve the mentioned problems. However, there are other problems in terms of distal migration during walking and the alignment of the orthosis which cannot be changed following the use of brace. Therefore, the main aim of the research was to design an orthosis to solve the aforementioned problems. Method. A new type of knee orthosis was designed with a modular structure. Two patients with knee OA participated in this research project. The force applied on the foot, moment transmitted through the knee joint, and spatiotemporal gait parameters were measured by use of a motion analysis system. Results. The results of the research showed that the adduction moment applied on the knee joint decreased while subjects walked with the new knee orthosis (P-value < 0.05. Conclusion. The new design of the knee brace can be used as an effective treatment to decrease the loads applied on the knee joint and to improve the alignment whilst walking.

  12. Preliminary results of anterior lumbar interbody fusion, anterior column realignment for the treatment of sagittal malalignment.

    Science.gov (United States)

    Hosseini, Pooria; Mundis, Gregory M; Eastlack, Robert K; Bagheri, Ramin; Vargas, Enrique; Tran, Stacie; Akbarnia, Behrooz A

    2017-12-01

    OBJECTIVE Sagittal malalignment decreases patients' quality of life and may require surgical correction to achieve realignment goals. High-risk posterior-based osteotomy techniques are the current standard treatment for addressing sagittal malalignment. More recently, anterior lumbar interbody fusion, anterior column realignment (ALIF ACR) has been introduced as an alternative for correction of sagittal deformity. The objective of this paper was to report clinical and radiographic results for patients treated using the ALIF-ACR technique. METHODS A retrospective study of 39 patients treated with ALIF ACR was performed. Patient demographics, operative details, radiographic parameters, neurological assessments, outcome measures, and preoperative, postoperative, and mean 1-year follow-up complications were studied. RESULTS The patient population comprised 39 patients (27 females and 12 males) with a mean follow-up of 13.3 ± 4.7 months, mean age of 66.1 ± 11.6 years, and mean body mass index of 27.3 ± 6.2 kg/m 2 . The mean number of ALIF levels treated was 1.5 ± 0.5. Thirty-three (84.6%) of 39 patients underwent posterior spinal fixation and 33 (84.6%) of 39 underwent posterior column osteotomy, of which 20 (60.6%) of 33 procedures were performed at the level of the ALIF ACR. Pelvic tilt, sacral slope, and pelvic incidence were not statistically significantly different between the preoperative and postoperative periods and between the preoperative and 1-year follow-up periods (except for PT between the preoperative and 1-year follow-up, p = 0.018). Sagittal vertical axis, T-1 spinopelvic inclination, lumbar lordosis, pelvic incidence-lumbar lordosis mismatch, intradiscal angle, and motion segment angle all improved from the preoperative to postoperative period and the preoperative to 1-year follow-up (p < 0.05). The changes in motion segment angle and intradiscal angle achieved in the ALIF-ACR group without osteotomy compared with the ALIF-ACR group with osteotomy

  13. The effect of proximal tibial slope on dynamic stability testing of the posterior cruciate ligament- and posterolateral corner-deficient knee.

    Science.gov (United States)

    Petrigliano, Frank A; Suero, Eduardo M; Voos, James E; Pearle, Andrew D; Allen, Answorth A

    2012-06-01

    Proximal tibial slope has been shown to influence anteroposterior translation and tibial resting point in the posterior cruciate ligament (PCL)-deficient knee. The effect of proximal tibial slope on rotational stability of the knee is unknown. Change in proximal tibial slope produced via osteotomy can influence both static translation and dynamic rotational kinematics in the PCL/posterolateral corner (PLC)-deficient knee. Controlled laboratory study. Posterior drawer, dial, and mechanized reverse pivot-shift (RPS) tests were performed on hip-to-toe specimens and translation of the lateral and medial compartments measured utilizing navigation (n = 10). The PCL and structures of the PLC were then sectioned. Stability testing was repeated, and compartmental translation was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5° or -5° of tibial slope variation, after which stability testing was repeated (n = 10). Analysis was performed using 1-way analysis of variance (ANOVA; α = .05). Combined sectioning of the PCL and PLC structures resulted in a 10.5-mm increase in the posterior drawer, 15.5-mm increase in the dial test at 30°, 14.5-mm increase in the dial test at 90°, and 17.9-mm increase in the RPS (vs intact; P slope (high tibial osteotomy [HTO] +5°) in the PCL/PLC-deficient knee reduced medial compartment translation by 3.3 mm during posterior drawer (vs deficient; P slope (HTO -5°) caused a 4.8-mm increase in medial compartment translation (vs deficient state; P slope diminished static posterior instability of the PCL/PLC-deficient knee as measured by the posterior drawer test but had little effect on rotational or dynamic multiplanar stability as assessed by the dial and RPS tests, respectively. Conversely, decreasing posterior slope resulted in increased posterior instability and a significant increase in the magnitude of the RPS. These results suggest that increasing posterior tibial slope may improve

  14. THE INFLUENCE OF HIP STRENGTH ON KNEE KINEMATICS DURING A SINGLE-LEGGED MEDIAL DROP LANDING AMONG COMPETITIVE COLLEGIATE BASKETBALL PLAYERS.

    Science.gov (United States)

    Suzuki, Hidetomo; Omori, Go; Uematsu, Daisuke; Nishino, Katsutoshi; Endo, Naoto

    2015-10-01

    A smaller knee flexion angle and larger knee valgus angle during weight-bearing activities have been identified as risk factors for non-contact anterior cruciate ligament (ACL) injuries. To prevent such injuries, attention has been focused on the role of hip strength in knee motion control. However, gender differences in the relationship between hip strength and knee kinematics during weight-bearing activities in the frontal plane have not been evaluated. The purpose of this study was to determine the influence of hip strength on knee kinematics in both genders during a single-legged landing task in the frontal plane. The hypotheses were that 1) subjects with a greater hip strength would demonstrate larger knee flexion and smaller knee valgus and internal rotation angles and 2) no gender differences would exist during the single-legged landing task. Forty-three Japanese collegiate basketball players (20 males, 23 females) participated in this study. Three-dimensional motion analysis was used to evaluate knee kinematics during a single-legged medial drop landing (SML). A hand-held dynamometer was used to assess hip extensor (HEXT), abductor (HAB), and external rotator (in two positions: seated position [SHER] and prone [PHER]) isometric strength. Spearman rank correlation coefficients (ρ) were determined for correlations between hip strength and knee kinematics at initial contact (IC) and peak (PK) during SML (p genders. Hip strength may, therefore, play an important role in knee motion control during sports activities, suggesting that increased hip strength may help to prevent non-contact ACL injuries in athletes of both genders. Moreover, gender-specific programs may be needed to control abnormal knee motion, as the influence of hip strength on knee kinematics may differ based on gender. 3.

  15. In vivo kinematics of healthy male knees during squat and golf swing using image-matching techniques.

    Science.gov (United States)

    Murakami, Koji; Hamai, Satoshi; Okazaki, Ken; Ikebe, Satoru; Shimoto, Takeshi; Hara, Daisuke; Mizu-uchi, Hideki; Higaki, Hidehiko; Iwamoto, Yukihide

    2016-03-01

    Participation in specific activities requires complex ranges of knee movements and activity-dependent kinematics. The purpose of this study was to investigate dynamic knee kinematics during squat and golf swing using image-matching techniques. Five healthy males performed squats and golf swings under periodic X-ray images at 10 frames per second. We analyzed the in vivo three-dimensional kinematic parameters of subjects' knees, namely the tibiofemoral flexion angle, anteroposterior (AP) translation, and internal-external rotation, using serial X-ray images and computed tomography-derived, digitally reconstructed radiographs. During squat from 0° to 140° of flexion, the femur moved about 25 mm posteriorly and rotated 19° externally relative to the tibia. Screw-home movement near extension, bicondylar rollback between 20° and 120° of flexion, and medial pivot motion at further flexion were observed. During golf swing, the leading and trailing knees (the left and right knees respectively in the right-handed golfer) showed approximately five millimeters and four millimeters of AP translation with 18° and 26° of axial rotation, respectively. A central pivot motion from set-up to top of the backswing, lateral pivot motion from top to ball impact, and medial pivot motion from impact to the end of follow-through were observed. The medial pivot motion was not always recognized during both activities, but a large range of axial rotation with bilateral condylar AP translations occurs during golf swing. This finding has important implications regarding the amount of acceptable AP translation and axial rotation at low flexion in replaced knees. IV. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Reverse Engineering Nature to Design Biomimetic Total Knee Implants.

    Science.gov (United States)

    Varadarajan, Kartik Mangudi; Zumbrunn, Thomas; Rubash, Harry E; Malchau, Henrik; Muratoglu, Orhun K; Li, Guoan

    2015-10-01

    While contemporary total knee arthroplasty (TKA) provides tremendous clinical benefits, the normal feel and function of the knee is not fully restored. To address this, a novel design process was developed to reverse engineer "biomimetic" articular surfaces that are compatible with normal soft-tissue envelope and kinematics of the knee. The biomimetic articular surface is created by moving the TKA femoral component along in vivo kinematics of normal knees and carving out the tibial articular surface from a rectangular tibial block. Here, we describe the biomimetic design process. In addition, we utilize geometric comparisons and kinematic simulations to show that; (1) tibial articular surfaces of conventional implants are fundamentally incompatible with normal knee motion, and (2) the anatomic geometry of the biomimetic surface contributes directly to restoration of normal knee kinematics. Such biomimetic implants may enable us to achieve the long sought after goal of a "normal" knee post-TKA surgery. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. Device-length changes and implant function following surgical implantation of the KineSpring in cadaver knees

    Directory of Open Access Journals (Sweden)

    McNicholas MJ

    2015-01-01

    Full Text Available Michael J McNicholas,1 Stefan M Gabriel,2 Anton G Clifford,2 Evelyne M Hasler2 1Aintree University Hospital, Teaching Hospital, Major Trauma Centre, NHS Foundation Trust, Liverpool, UK; 2Moximed, Hayward, CA, USA Introduction: The KineSpring implant system has been shown to provide load reductions at the medial compartment of the knee, and has demonstrated clinical success in reducing pain and increasing function in patients with medial knee osteoarthritis. These results depend on the ability of the KineSpring to rotate, lengthen, and shorten to accommodate knee motions, and in response to knee position and loading. Purpose: The present study was undertaken to determine length changes of the implanted KineSpring in response to a range of knee positions, external knee loads, and placements by different orthopedic surgeons. Materials and methods: KineSpring system components were implanted in ten cadaver leg specimens by ten orthopedic surgeons, and absorber-length changes were measured under combined loading and in different positions of the knee. Results and conclusion: Spring compression consistent with knee-load reduction, and device lengthening and shortening to accommodate knee loads and motions were seen. These confirm the functionality of the KineSpring when implanted medially to the knee. Keywords: KineSpring, knee, function, preservation, offloading, osteoarthritis

  18. Effect of a physiotherapy rehabilitation program on knee osteoarthritis in patients with different pain intensities.

    Science.gov (United States)

    Abdel-Aziem, Amr Almaz; Soliman, Elsadat Saad; Mosaad, Dalia Mohammed; Draz, Amira Hussin

    2018-02-01

    [Purpose] To examine the effect of physiotherapy rehabilitation program on moderate knee osteoarthritis in patients with different pain intensities. [Subjects and Methods] Sixty subjects (37 men and 23 women) with moderate knee osteoarthritis participated in the current study. Randomization software was used to select the participating subjects' numbers from the clinic records. They were classified into three groups according to pain intensity: mild, moderate, and severe pain groups. All groups underwent a standard set of pulsed electromagnetic field, ultrasound, stretching exercises, and strengthening exercises. Pain intensity, knee range of motion, knee function, and isometric quadriceps strength were evaluated using the visual analogue scale, universal goniometer, Western Ontario and McMaster Universities osteoarthritis index, and Jamar hydraulic dynamometer, respectively. The evaluation was performed before and after a 4-week rehabilitation program. [Results] All groups showed significant differences in pain intensity, knee range of motion, isometric quadriceps strength, and knee function. The score change in moderate pain group was significantly greater than those in mild and severe pain groups. [Conclusion] Pain intensity is one of the prominent factors that are responsible for the improvement of knee osteoarthritis. Consequently, pain intensity should be considered during rehabilitation of knee osteoarthritis.

  19. [CLINICAL APPLICATION OF OXFORD MOBILE-BEARING BIPOLAR PROSTHESIS UNICOMPARTMENTAL KNEE ARTHROPLASTY FOR SINGLE COMPARTMENTAL KNEE OSTEOARTHRITIS].

    Science.gov (United States)

    Wang, Shangzeng; Cheng, Shao; Wang, Yisheng

    2016-01-01

    To evaluate the effectiveness of Oxford mobile-bearing bipolar prosthesis unicompartmental knee arthroplasty (UKA) in the treatment of single compartmental knee osteoarthritis. Between June 2011 and July 2013, 22 cases of single compartmental knee osteoarthritis were treated by Oxford mobile-bearing bipolar prosthesis UKA. Of 22 cases, 8 were male and 14 were female with an average age of 65 years (range, 45-80 years); the left knee was involved in 12 cases, and the right knee in 10 cases, with a mean disease duration of 32.5 months (range, 8-90 months). The mean weight was 55.2 kg (range, 50-65 kg), and the mean body mass index was 20.8 kg/m2 (range, 17-25 kg/m2). Osteoarthritis involved in the single knee medial compartment in all patients. Knee society score (KSS) and range of motion (ROM) were measured to evaluate the knee joint function. Primary healing of incision was obtained in all patients, and there was no complication of infection, bedsore, or deep venous thrombosis. Postoperative follow-up was 2-4 years (mean, 3.2 years). The X-ray films showed good position of prosthesis, no prosthesis dislocation, or periprosthetic infection during follow-up. Knee ROM, KSS function score, and KSS clinical score were significantly improved at 1 week after operation and at last follow-up when compared with preoperative ones (P 0.05). Oxford mobile-bearing bipolar prosthesis UKA is an effective method to treat single compartmental knee osteoarthritis, with the advantages of less trauma, earlier rehabilitation exercise, near physiological state in joint function, and less risk of complications.

  20. In vivo kinematics of a robot-assisted uni- and multi-compartmental knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Abbasi, Ali Z; Conditt, Michael A; Christopher, Jennifer; Kreuzer, Stefan; Otto, Jason K; Banks, Scott A

    2014-07-01

    There is great interest in providing reliable and durable treatments for one- and two-compartment arthritic degeneration of the cruciate-ligament intact knee. One approach is to resurface only the diseased compartments with discrete unicompartmental components, retaining the undamaged compartment(s). However, placing multiple small implants into the knee presents a greater surgical challenge than total knee arthroplasty, so it is not certain that the natural knee mechanics can be maintained or restored. The goal of this study was to determine whether near-normal knee kinematics can be obtained with a robot-assisted multi-compartmental knee arthroplasty. Thirteen patients with 15 multi-compartmental knee arthroplasties using haptic robotic-assisted bone preparation were involved in this study. Nine subjects received a medial unicompartmental knee arthroplasty (UKA), three subjects received a medial UKA and patellofemoral (PF) arthroplasty, and three subjects received medial and lateral bi-unicondylar arthroplasty. Knee motions were recorded using video-fluoroscopy an average of 13 months (6-29 months) after surgery during stair and kneeling activities. The three-dimensional position and orientation of the implant components were determined using model-image registration techniques. Knee kinematics during maximum flexion kneeling showed femoral external rotation and posterior lateral condylar translation. All knees showed femoral external rotation and posterior condylar translation with flexion during the step activity. Knees with medial UKA and PF arthroplasty showed the most femoral external rotation and posterior translation, and knees with bicondylar UKA showed the least. Knees with accurately placed uni- or bi-compartmental arthroplasty exhibited stable knee kinematics consistent with intact and functioning cruciate ligaments. The patterns of tibiofemoral motion were more similar to natural knees than commonly has been observed in knees with total knee

  1. Development and validation of a computational model of the knee joint for the evaluation of surgical treatments for osteoarthritis.

    Science.gov (United States)

    Mootanah, R; Imhauser, C W; Reisse, F; Carpanen, D; Walker, R W; Koff, M F; Lenhoff, M W; Rozbruch, S R; Fragomen, A T; Dewan, Z; Kirane, Y M; Cheah, K; Dowell, J K; Hillstrom, H J

    2014-01-01

    A three-dimensional (3D) knee joint computational model was developed and validated to predict knee joint contact forces and pressures for different degrees of malalignment. A 3D computational knee model was created from high-resolution radiological images to emulate passive sagittal rotation (full-extension to 65°-flexion) and weight acceptance. A cadaveric knee mounted on a six-degree-of-freedom robot was subjected to matching boundary and loading conditions. A ligament-tuning process minimised kinematic differences between the robotically loaded cadaver specimen and the finite element (FE) model. The model was validated by measured intra-articular force and pressure measurements. Percent full scale error between FE-predicted and in vitro-measured values in the medial and lateral compartments were 6.67% and 5.94%, respectively, for normalised peak pressure values, and 7.56% and 4.48%, respectively, for normalised force values. The knee model can accurately predict normalised intra-articular pressure and forces for different loading conditions and could be further developed for subject-specific surgical planning.

  2. Impact of Simulated Knee Injuries on the Patellofemoral and Tibiofemoral Kinematics Investigated with an Electromagnetic Tracking Approach: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Björn Rath

    2018-01-01

    Full Text Available Purpose. The purpose of this study was to evaluate the approach of using an electromagnetic tracking (EMT system for measuring the effects of stepwise, simulated knee injuries on patellofemoral (PF and tibiofemoral (TF kinematics. Methods. Three cadaver knees were placed in a motion rig. EMT sensors were mounted on the patella, the medial/lateral femoral epicondyles, the tibial condyle, and the tibial tuberosity (TT. After determining the motion of an intact knee, three injuries were simulated and the resulting bony motion was tracked. Results. Starting with the intact knee fully extended (0° flexion and bending it to approximately 20°, the patella shifted slightly in the medial direction. Then, while bending the knee to the flexed position (90° flexion, the patella shifted progressively more laterally. After transecting the anterior cruciate ligament (ACL, the base of the medial menisci (MM at the pars intermedia, and the medial collateral ligament (MCL, individual changes were observed. For example, the medial femoral epicondyle displayed a medial lift-off in all knees. Conclusion. We demonstrated that our EMT approach is an acceptable method to accurately measure PF joint motion. This method could also enable visualization and in-depth analysis of in vivo patellar function in total knee arthroplasty, if it is established for routine clinical use.

  3. The Analysis of Knee Joint Movement During Golf Swing in Professional and Amateur Golfers

    OpenAIRE

    M.Somjarod; V. Tanawat; l. Weerawat

    2011-01-01

    The understanding of knee movement during swing importance for golf swing improving and preventing injury. Thirty male professional and amateur golfers were assigned to swing time by time for 3 times. Data from a vedio-based motion capture were used to compute knee joint movement variables. The results showed that professional and amateur golfers were significantly in left knee flexion angle at the impact point and mid follow through phase. Nevertheless, left knee externa...

  4. Acute proximal junctional failure in patients with preoperative sagittal imbalance.

    Science.gov (United States)

    Smith, Micah W; Annis, Prokopis; Lawrence, Brandon D; Daubs, Michael D; Brodke, Darrel S

    2015-10-01

    Proximal junctional failure (PJF) is a recognized complication of spinal deformity surgery. Acute PJF (APJF) has recently been demonstrated to be 5.6% in the adult spinal deformity (ASD) population. The incidence and rate of return to the operating room for APJF have not been specifically investigated in individuals with sagittal imbalance. The purpose of this study was to report the incidence of APJF in patients with preoperative sagittal imbalance and the rate of return to the operating room for APJF. This study is based on a retrospective review of prospectively collected database of ASD patients. One hundred seventy-three consecutive patients were included with preoperative sagittal imbalance according to one of the following common parameters: sagittal vertical axis (SVA) greater than 50 mm, global sagittal alignment greater than 45°, or pelvic incidence minus lumbar lordosis greater than 10°. Outcome measure was presence and/or absence of APJF defined as fracture at the upper instrumented vertebra (UIV) or UIV+1, failure of UIV fixation, 15° or more proximal junctional kyphosis, or need for extension of instrumentation within 6 months of surgery. We performed radiographic measurements on X-rays at preoperative, immediate postoperative, and 6-month follow-up visits. The APJF rate was reported for the entire patient population with preoperative sagittal imbalance. Acute PJF incidence was calculated postoperatively for each of the accepted sagittal balance parameters and/or formulas. Patients with persistent postoperative sagittal imbalance were compared with the sagittally balanced group. We also assessed for threshold values. Acute PJF was observed in 60 of 173 patients (35%) and was least common in fusions with the UIV in the upper thoracic (UT) spine (p=.035). Of those who developed APJF, 21.7% required surgery. Proximal junctional kyphosis 15° or more was the most common form of APJF in fusions to the UT spine but least likely to need revision (p=.014

  5. Effects of therapeutic exercise and hydrotherapy on pain severity and knee range of motion in patients with hemophilia: a randomized controlled trial.

    Science.gov (United States)

    Mazloum, Vahid; Rahnama, Nader; Khayambashi, Khalil

    2014-01-01

    Pain and limited range of motion (ROM) are the crucial subsequent results of joint hemorrhages in individuals with bleeding disorders and hemophilia. Exercise interventions are particularly recommended in treatment of such patients. The purpose of this study was to detect the influences of conventional exercise therapy and hydrotherapy on the knee joint complications in patients with hemophilia. A total of 40 patients engaging hemophilia A were randomized into one of three groups: Therapeutic exercise (N = 13), hydrotherapy (N = 14) or control (N = 13). While the first two groups followed their specific programs for 4 weeks, routine life-style was maintained by subjects in the control group in this period. To evaluate the pain level and knee ROM the visual analog scale and standard goniometer were utilized, respectively. The outcome was measured at baseline and after completing the prescribed protocols. Data analysis was performed using one-way analysis of variance and Scheffe statistical tests (P hydrotherapy in comparison to exercise therapy, the difference in ROM improvement was not statistically significant (P > 0.05). Using hydrotherapy in addition to usual rehabilitation training can result in beneficial effect in terms of pain and knee joint ROM. However, it appears that hydrotherapy is more effective in reducing pain.

  6. ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6-10 months.

    Science.gov (United States)

    Heinlein, Bernd; Kutzner, Ines; Graichen, Friedmar; Bender, Alwina; Rohlmann, Antonius; Halder, Andreas M; Beier, Alexander; Bergmann, Georg

    2009-05-01

    Detailed information about the loading of the knee joint is required for various investigations in total knee replacement. Up to now, gait analysis plus analytical musculo-skeletal models were used to calculate the forces and moments acting in the knee joint. Currently, all experimental and numerical pre-clinical tests rely on these indirect measurements which have limitations. The validation of these methods requires in vivo data; therefore, the purpose of this study was to provide in vivo loading data of the knee joint. A custom-made telemetric tibial tray was used to measure the three forces and three moments acting in the implant. This prosthesis was implanted into two subjects and measurements were obtained for a follow-up of 6 and 10 months, respectively. Subjects performed level walking and going up and down stairs using a self-selected comfortable speed. The subjects' activities were captured simultaneously with the load data on a digital video tape. Customized software enabled the display of all information in one video sequence. The highest mean values of the peak load components from the two subjects were as follows: during level walking the forces were 276%BW (percent body weight) in axial direction, 21%BW (medio-lateral), and 29%BW (antero-posterior). The moments were 1.8%BW*m in the sagittal plane, 4.3%BW*m (frontal plane) and 1.0%BW*m (transversal plane). During stair climbing the axial force increased to 306%BW, while the shear forces changed only slightly. The sagittal plane moment increased to 2.4%BW*m, while the frontal and transversal plane moments decreased slightly. Stair descending produced the highest forces of 352%BW (axial), 35%BW (medio-lateral), and 36%BW (antero-posterior). The sagittal and frontal plane moments increased to 2.8%BW*m and 4.6%BW*m, respectively, while the transversal plane moment changed only slightly. Using the data obtained, mechanical simulators can be programmed according to realistic load profiles. Furthermore

  7. FUNCTIONAL DISABILITY, SAGITTAL ALIGNMENT AND PELVIC BALANCE IN LUMBAR SPONDYLOLISTHESIS

    Directory of Open Access Journals (Sweden)

    Luis Muñiz Luna

    2016-03-01

    Full Text Available ABSTRACT Objectives: To demonstrate the recovery of lumbar sagittal pelvic alignment and sagittal pelvic balance after surgical reduction of lumbar spondylolisthesis and establish the benefits of the surgery for reduction and fixation of the lumbar spondylolisthesis with 360o circumferential arthrodesis for 2 surgical approaches by clinical and functional evaluation. Method: Eight patients with lumbar spondylolisthesis treated with surgical reduction and fixation of listhesis and segmental circumferential fusion with two surgical approaches were reviewed. They were evaluated before and after treatment with Oswestry, Visual Analogue for pain and Odom scales, performing radiographic measurement of lumbar sagittal alignment and pelvic sagittal balance with the technique of pelvic radius. Results: Oswestry scales and EVA reported improvement of symptoms after treatment in 8 cases; the Odom scale had six outstanding cases reported. The lumbar sagittal alignment presented a lumbosacral lordosis angle and a lumbopelvic lordosis angle reduced in 4 cases and increased in 4 other cases; pelvic sagittal balance increased the pelvic angle in 4 cases and decreased in 3 cases and the sacral translation of the hip axis to the promontory increased in 6 cases. Conclusion: The surgical procedure evaluated proved to be useful by modifying the lumbar sagittal alignment and the pelvic balance, besides reducing the symptoms, enabling the patient to have mobility and movement and the consequent satisfaction with the surgery.

  8. Nordic Walking does not reduce the loading of the knee joint

    DEFF Research Database (Denmark)

    Hansen, L; Henriksen, Michael; Larsen, P

    2008-01-01

    and the knee joint compressive forces were calculated. No differences in compression or shear forces between NW and NP were found. The peak knee flexion angles were larger during NW (-32.5+/-6.0 degrees) compared with NP (-28.2+/-4.2 degrees). The hip range of motion (ROM) was significantly increased during NW...

  9. Patient cloth with motion recognition sensors based on flexible piezoelectric materials.

    Science.gov (United States)

    Youngsu Cha; Kihyuk Nam; Doik Kim

    2017-07-01

    In this paper, we introduce a patient cloth for position monitoring using motion recognition sensors based on flexible piezoelectric materials. The motion recognition sensors are embedded in three parts, which are the knee, hip and back, in the patient cloth. We use polyvinylidene fluoride (PVDF) as the flexible piezoelectric material for the sensors. By using the piezoelectric effect of the PVDF, we detect electrical signals when the cloth is bent or extended. We analyze the sensing values for our human motions by processing the sensor outputs in a custom-made program. Specifically, we focus on the transitions between standing and sitting, and sitting knee extension and supine position, which are important motions for patient monitoring.

  10. Short Term Effects of Kinesiotape Application in Patients with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Zeliha Başkurt

    2017-11-01

    Full Text Available Objective: The purpose of this prospective, randomized, controlled study is to determine the effect of kinesiotape on pain, range of motion, muscle strength and lower extremity functions in medial compartmental osteoarthritis patients. Materials and Methods: Patients with medial compartmental knee osteoarthritis were participated in the study. They were randomized into two groups. While kinesiotaping was applied to the first group (n:23, six men, 17 women; age: 57.6±11.5 yrs; BMI: 28.8±4.3 kg/m2; 15 right, eight left knee, sham taping was applied to the second group (n:22, five men, 17 women; age: 61.1±7.0 yrs; BMI: 31.1±4.1 kg/m2; 13 right, nine left knee twice, three days apart. Visual pain scale, knee range of motion, muscle strength measurements, and Lower Extremity Functional Scale scores were recorded at baseline, immediately following the first taping, three days and seven days later. Results: Kinesiotape outperformed sham tape statistically significantly in the test parameters (p

  11. MR imaging appearance of discoid menisci of the knee

    International Nuclear Information System (INIS)

    Silverman, J.; Mink, J.H.; Deutsch, A.L.

    1988-01-01

    Although discoid menisci of the knee have been recognized with magnetic resonance (MR) imaging, there are no MR criteria for their diagnosis. In this paper the authors define a discord meniscus as three or more 5-mm-thick interleaved sagittal sections that demonstrate continuity of the meniscus between the anterior and posterior horns. High-resolution coronal images allow more graphic depiction of the abnormally wide meniscus. They present a total of 29 cases imaged with MR. In approximately one-third of their cases, the measurable height difference between the discoid meniscus and the adjacent meniscus was at least 2 mm. Surgical correlation revealed only two discrepancies between MR imaging and arthrography

  12. Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study.

    Science.gov (United States)

    Erdem, Mehmet; Gulabi, Deniz; Cecen, Gultekin Sitki; Avci, Cem Coskun; Asci, Murat; Saglam, Fevzi

    2015-07-01

    One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1° ± 0.8°. The mean postoperative tibial sagittal angle measurements were 83.3° ± 1.4° (81°-86°). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5° ± 3°). The mean postoperative tibial coronal angle was 89.3° ± 1.5°. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.

  13. Intraoperative joint gaps and mediolateral balance affect postoperative knee kinematics in posterior-stabilized total knee arthroplasty.

    Science.gov (United States)

    Watanabe, Toshifumi; Muneta, Takeshi; Sekiya, Ichiro; Banks, Scott A

    2015-12-01

    Adjusting joint gaps and establishing mediolateral (ML) soft tissue balance are considered essential interventions for better outcomes in total knee arthroplasty (TKA). However, the relationship between intraoperative laxity measurements and weightbearing knee kinematics has not been well explored. This study aimed to quantify the effect of intraoperative joint gaps and ML soft tissue balance on postoperative knee kinematics in posterior-stabilized (PS)-TKA. We investigated 44 knees in 34 patients who underwent primary PS-TKA by a single surgeon. The central joint gaps and ML tilting angles at 0°, 10°, 30°, 60°, 90°, 120° and 135° flexion were measured during surgery. At a minimum of two year follow-up, we analyzed in vivo kinematics of these knees and examined the influence of intraoperative measurements on postoperative kinematics. Gap difference of knee flexion at 135° minus 0° was correlated with the total posterior translation of lateral femoral condyle (r=0.336, p=0.042) and femoral external rotation (r=0.488, p=0.002) during squatting, anteroposterior position of lateral femoral condyle (r=-0.510, p=0.001) and maximum knee flexion (r=0.355, p=0.031) in kneeling. Similar correlations were observed between deep flexion gap differences with respect to the 90° reference and postoperative knee kinematics. Well-balanced knees showed less anterior translation of medial femoral condyle in mid- to deep flexion, consistent femoral external rotation, and the most neutral valgus/varus rotation compared with unbalanced knees. These findings indicate the importance of adequate intraoperative joint gaps in deep flexion and ML soft tissue balance throughout the range of motion. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Knee Muscular Control During Jump Landing in Multidirections.

    Science.gov (United States)

    Sinsurin, Komsak; Vachalathiti, Roongtiwa; Jalayondeja, Wattana; Limroongreungrat, Weerawat

    2016-06-01

    Jump landing is a complex movement in sports. While competing and practicing, athletes frequently perform multi-planar jump landing. Anticipatory muscle activity could influence the amount of knee flexion and prepare the knee for dynamic weight bearing such as landing tasks. The aim of the present study was to examine knee muscle function and knee flexion excursion as athletes naturally performed multi-direction jump landing. Eighteen male athletes performed the jump-landing test in four directions: forward (0°), 30° diagonal, 60° diagonal, and lateral (90°). Muscles tested were vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF), semitendinosus (ST), and biceps femoris (BF). A Vicon(TM) 612 workstation collected the kinematic data. An electromyography was synchronized with the Vicon(TM) Motion system to quantify dynamic muscle function. Repeated measure ANOVA was used to analyze the data. Jump-landing direction significantly influenced (P jump landing. A higher risk of knee injury might occur during lateral jump landing than forward and diagonal directions. Athletes should have more practice in jump landing in lateral direction to avoid injury. Landing technique with high knee flexion in multi-directions should be taught to jumpers for knee injury prevention.

  15. Lower extremity energy absorption and biomechanics during landing, part II: frontal-plane energy analyses and interplanar relationships.

    Science.gov (United States)

    Norcross, Marc F; Lewek, Michael D; Padua, Darin A; Shultz, Sandra J; Weinhold, Paul S; Blackburn, J Troy

    2013-01-01

    Greater sagittal-plane energy absorption (EA) during the initial impact phase (INI) of landing is consistent with sagittal-plane biomechanics that likely increase anterior cruciate ligament (ACL) loading, but it does not appear to influence frontal-plane biomechanics. We do not know whether frontal-plane INI EA is related to high-risk frontal-plane biomechanics. To compare biomechanics among INI EA groups, determine if women are represented more in the high group, and evaluate interplanar INI EA relationships. Descriptive laboratory study. Research laboratory. Participants included 82 (41 men, 41 women; age = 21.0 ± 2.4 years, height = 1.74 ± 0.10 m, mass = 70.3 ± 16.1 kg) healthy, physically active volunteers. We assessed landing biomechanics with an electromagnetic motion-capture system and force plate. We calculated frontal- and sagittal-plane total, hip, knee, and ankle INI EA. Total frontal-plane INI EA was used to create high, moderate, and low tertiles. Frontal-plane knee and hip kinematics, peak vertical and posterior ground reaction forces, and peak internal knee-varus moment (pKVM) were identified and compared across groups using 1-way analyses of variance. We used a χ (2) analysis to evaluate male and female allocation to INI EA groups. We used simple, bivariate Pearson product moment correlations to assess interplanar INI EA relationships. The high-INI EA group exhibited greater knee valgus at ground contact, hip adduction at pKVM, and peak hip adduction than the low-INI EA group (P .05). Greater frontal-plane INI EA was associated with less favorable frontal-plane biomechanics that likely result in greater ACL loading. Women were more likely than men to use greater frontal-plane INI EA. The magnitudes of sagittal- and frontal-plane INI EA were largely independent.

  16. Knee joint anterior malalignment and patellofemoral osteoarthritis: an MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Tsavalas, Nikolaos; Karantanas, Apostolos H. [University Hospital, University of Crete, Department of Medical Imaging, Heraklion, Crete (Greece); Katonis, Pavlos [University Hospital, University of Crete, Department of Orthopaedic Surgery, Heraklion, Crete (Greece)

    2012-02-15

    To evaluate patellofemoral congruency measurements on MRI and correlate the findings with severity of ipsilateral osteoarthritis. We retrospectively reviewed 650 consecutive knee MRI examinations from 622 patients divided into two age groups: {<=}50 and >50 year-old. The femoral sulcus angle (SA) and depth (SD), lateral patellar displacement (LPD), lateral patellofemoral angle (LPFA), tibial tubercle-trochlear groove (TT-TG) distance and Insall-Salvati index as well as the grade of focal cartilage defects (ranging from I to IV) in the patellofemoral region were assessed in each subject on axial and sagittal fat-saturated intermediate-w MR images. A significant difference exists between normal and knees with patellofemoral joint osteoarthritis regarding SA (p = 0.0002 and <0.0001), SD (p = 0.0004 and <0.0001), LPD (p = 0.0014 and 0.0009) and LPFA (p = 0.0002 and 0.0003) in both age groups ({<=}50 and >50 respectively). Significant correlation was found between grading of cartilage defects and SA (rho = 0.21, p = 0.0001 and 0.443, <0.0001), SD (rho = -0.198, p = 0.0003 and -0.418, <0.0001), LPD (rho = 0.176, p = 0.0013 and 0.251, 0.0002) and LPFA (rho = -0.204, p = 0.0002 and -0.239, 0.0005) in both age groups. Knee joint anterior malalignment is multivariably associated with patellofemoral osteoarthritis. circle MRI is an excellent method to evaluate knee alignment and articular cartilage damage. (orig.)

  17. Subchondral cysts of the tibia secondary to osteoarthritis of the knee

    International Nuclear Information System (INIS)

    Ostlere, S.J.; Seeger, L.L.; Eckardt, J.J.

    1990-01-01

    Subchondral cysts of the tibia secondary to osteoarthritis of the knee are not usually seen on radiographs. When present, they are typically small and present no diagnostic difficulty. Two cases of unusually large subchondral lesions of the medial tibial plateau are presented. The lesions were well defined and lay adjacent to the medial tibial cortex with their long axes in the sagittal plane. Both were associated with moderate medial compartment osteoarthritis. Additional information obtained from computed tomography indicated that these lesions were subchondral cysts secondary to osteoarthritis rather than tumors or other tumor-like conditions. (orig.)

  18. [Surgical technique and clinical results of total knee arthroplasty in treating endstage gonarthrosis combined with valgus knee deformity].

    Science.gov (United States)

    Wang, Xingshan; Weng, Xisheng; Lin, Jin; Jin, Jin; Qian, Wenwei

    2012-05-01

    To investigate the surgical technique and the clinical results of total knee arthroplasty (TKA) in treating end-stage gonarthrosis combined with valgus knee deformity. Between November 1998 and October 2010, 64 patients (72 knees) with end-stage gonarthrosis combined with valgus knee deformity underwent TKA by a medial parapatellar approach. Of the 64 patients, 18 were male and 46 were female with an average age of 62.5 years (range, 23-82 years), including 44 cases (49 knees) of osteoarthritis, 17 cases (20 knees) of rheumatoid arthritis, 2 cases (2 knees) of haemophilic arthritis, and 1 case (1 knee) of post-traumatic arthritis. Bilateral knees were involved in 8 cases, and single knee in 56 cases. The flexion and extension range of motion (ROM) of the knee joint was (82.2 +/- 28.7) degrees; the femur-tibia angle (FTA) was (18.0 +/- 5.8) degrees; according to Knee Society Score (KSS) criterion, the preoperative clinical score was 31.2 +/- 10.1 and functional score was 37.3 +/- 9.0. According to Krackow's classification, there were 65 knees of type I and 7 knees of type II. By medial parapatellar approach, conventional osteotomy and Ranawat soft tissue release were performed in all cases. Prosthesis of preserved posterior cruciate ligament were used in 7 cases (7 knees), posterior stabilize prosthesis in 54 cases (60 knees), constrained prosthesis in 4 cases (5 knees). Incisions healed by first intention in all cases. Peroneal nerve palsy occurred in 1 patient with haemophilic arthritis, severe valgus deformity (FTA was 41 degrees), and flexion contracture (20 degrees), which was cured after 1 year of conservative treatment. Revison surgery was performed in 1 case of deep infection at 2 years after surgery. All the patients were followed up 4.9 years on average (range, 1-13 years). At last follow-up, the FTA was (7.0 +/- 2.5) degrees, showing significant difference when compared with preoperative value (t = 15.502, P = 0.000). The KSS clinical score was 83.0 +/- 6

  19. Temporomandibular joint motion

    International Nuclear Information System (INIS)

    Maeda, M.; Kawamura, Y.; Matsuda, T.; Itou, S.; Odori, T.; Ishii, Y.; Torizuka, K.

    1990-01-01

    This paper evaluates MR imaging with the therapeutic effect after splint therapy in internal derangement of the temporomandibular joint (TMJ). Fifteen patients (19 TMJs) with internal derangement of the TMJ and five normal volunteers (10 TMJs) were examined with sagittal T1-weighted spin-echo and gradient recalled acquisition in a steady state (GRASS) MR imaging. MR studies of the patients undergoing splint therapy were performed with an without splints. Pseudodynamic images of TMJ motion provide information that was not available from spin-echo T1-weighted images

  20. Effect of Mulligan's and Kinesio knee taping on adolescent ballet dancers knee and hip biomechanics during landing.

    Science.gov (United States)

    Hendry, D; Campbell, A; Ng, L; Grisbrook, T L; Hopper, D M

    2015-12-01

    Taping is often used to manage the high rate of knee injuries in ballet dancers; however, little is known about the effect of taping on lower-limb biomechanics during ballet landings in the turnout position. This study investigated the effects of Kinesiotape (KT), Mulligan's tape (MT) and no tape (NT) on knee and hip kinetics during landing in three turnout positions. The effect of taping on the esthetic execution of ballet jumps was also assessed. Eighteen pain-free 12-15-year-old female ballet dancers performed ballet jumps in three turnout positions, under the three knee taping conditions. A Vicon Motion Analysis system (Vicon Oxford, Oxford, UK) and Advanced Mechanical Technology, Inc. (Watertown, Massa chusetts, USA) force plate collected lower-limb mechanics. The results demonstrated that MT significantly reduced peak posterior knee shear forces (P = 0.025) and peak posterior (P = 0.005), medial (P = 0.022) and lateral (P = 0.014) hip shear forces compared with NT when landing in first position. KT had no effect on knee or hip forces. No significant differences existed between taping conditions in all landing positions for the esthetic measures. MT was able to reduce knee and the hip forces without affecting the esthetic performance of ballet jumps, which may have implications for preventing and managing knee injuries in ballet dancers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Predicting dynamic knee joint load with clinical measures in people with medial knee osteoarthritis.

    Science.gov (United States)

    Hunt, Michael A; Bennell, Kim L

    2011-08-01

    Knee joint loading, as measured by the knee adduction moment (KAM), has been implicated in the pathogenesis of knee osteoarthritis (OA). Given that the KAM can only currently be accurately measured in the laboratory setting with sophisticated and expensive equipment, its utility in the clinical setting is limited. This study aimed to determine the ability of a combination of four clinical measures to predict KAM values. Three-dimensional motion analysis was used to calculate the peak KAM at a self-selected walking speed in 47 consecutive individuals with medial compartment knee OA and varus malalignment. Clinical predictors included: body mass; tibial angle measured using an inclinometer; walking speed; and visually observed trunk lean toward the affected limb during the stance phase of walking. Multiple linear regression was performed to predict KAM magnitudes using the four clinical measures. A regression model including body mass (41% explained variance), tibial angle (17% explained variance), and walking speed (9% explained variance) explained a total of 67% of variance in the peak KAM. Our study demonstrates that a set of measures easily obtained in the clinical setting (body mass, tibial alignment, and walking speed) can help predict the KAM in people with medial knee OA. Identifying those patients who are more likely to experience high medial knee loads could assist clinicians in deciding whether load-modifying interventions may be appropriate for patients, whilst repeated assessment of joint load could provide a mechanism to monitor disease progression or success of treatment. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Reliability of cervical lordosis and global sagittal spinal balance measurements in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Azoulay, Robin; Sebag, Guy; Mazda, Keyvan

    2013-06-01

    Radiological reproducibility study. To assess intra and interobserver reliability of radiographic measurements for global sagittal balance parameters and sagittal spine curves, including cervical spine. Sagittal spine balance in adolescent idiopathic scoliosis (AIS) is a main issue and many studies have been reported, showing that coronal and sagittal deformities often involve sagittal cervical unbalance. Global sagittal balance aims to obtain a horizontal gaze and gravity line at top of hips when subject is in a static position, involving adjustment of each spine curvature in the sagittal plane. To our knowledge, no study did use a methodologically validated imaging analysis tool able to appreciate sagittal spine contours and distances in AIS and especially in the cervical region. Lateral full-spine low-dose EOS radiographs were performed in 75 patients divided in three groups (control subjects, AIS, operated AIS). Three observers digitally analyzed twice each radiograph and 11 sagittal measures were collected for each image. Reliability was assessed calculating intraobserver Pearson's r correlation coefficient, interobserver intra-class correlation coefficient (ICC) completed with a two-by-two Bland-Altman plot analysis. This measurement method has shown excellent intra and interobserver reliability in all parameters, sagittal curvatures, pelvic parameters and global sagittal balance. This study validated a simple and efficient tool in AIS sagittal contour analysis. It defined new relevant landmarks allowing to characterize cervical segmental curvatures and cervical involvement in global balance.

  3. Evaluation of meniscal subluxation of the knee with MR imaging

    International Nuclear Information System (INIS)

    Kim, Hyun Chul; Park, Jin Gyoon; Kang, Heoung Keun; Kim, Jae Kyu; Seo, Jeong Jin; Kim, Yun Hyeon; Chung, Tae Woong

    2000-01-01

    The purpose of this study was to determine the normal meniscal position and meniscal subluxation by means of MR imaging. The normal position of the meniscus was determined by measuring the distance between the peripheral meniscal borders and the tibial plateau, as seen on coronal, sagittal and oblique MR images of 40 normal knees. For 33 abnormal knees in which outward subluxation of the meniscus from the tibial plateau was noted, the involved site, the predisposing factor, and the frequency of meniscus tearing were analyzed. In normal knees, the peripheral border of the meniscus extruded 3mm or less from the peripheral border of the tibial plateau. Among 33 abnormal knees, in which 5mm or more outward subluxation of the meniscus was seen, 19 menisci were medial and 14 were lateral. Among the 19, the body was involved in 12, the anterior horn in six, and the posterior horn in one. With regard to the 14 lateral subluxations, involvement of the posterior horn occurred in ten, of both the body and posterior horn in two, of the anterior horn in one, and of the body in one. The common predisposing factor in medial meniscus subluxation was osteoarthritis, seen in 89% of such cases, and in lateral subluxation, anterior cruciate ligament tear, which occurred in 79% of cases. Medial meniscus tear was noted in 89% of medial meniscus subluxations and lateral meniscus tear in 43% of lateral subluxations. Meniscal subluxation was easily detected by MR imaging of the knee. The common predisposing factor in medial meniscus subluxation was osteoarthritis, and in lateral meniscus subluxation, anterior cruciate ligament tear. A torn meniscus frequently co-occurred

  4. Total knee reconstruction without posterior stabilization in rheumatoid arthritis patients

    Directory of Open Access Journals (Sweden)

    Radu Prejbeanu

    2010-12-01

    Full Text Available Objectives: to present the results with posterior cruciate ligament-retaining total knee arthroplasty in rheumatoid arthritis (RA patients. Background: Total knee replacement in RA patients has many particularities. One of them is the difficulty of obtaining a proper ligamentous balance.Methods: 24 RA patients were followed for a 5-year period after posterior cruciate ligament-retaining total knee arthroplasty. Clinical assessments analyzed general health status by using Hospital for Special Surgery Knee Evaluation Form (HSSKEF and mediolateral and anteroposterior ligament stability by using varus-valgus and posterior drawer tests. Radiological assessments evaluated axial alignment, size and position of components, radiolucent lines in anteroposterior and lateral standard views, integrity of the posterior cruciate ligament on lateral view X-ray at 45 degrees of flexion.Results: the mean HSSKEF score increased from 32 to 84 points at the end of follow-up. Preoperative mean range of motion was 60 degrees; postoperative mean range of motion was of 105 degrees, with significant statistical difference (p<0.05. The mean femoral component axial deviation was 6 degrees. The tibial component had a mean axial deviation of 1 degree of varus. There were no radioluscency lines of more than 1mm. 21 patients had excellent results. None of the knees was unstable. Conclusion: posterior cruciate ligament-retaining total knee arthroplasty can be used in RA patients without excessive valgus deformity (over 15 degrees, providing thus sufficient stabilization. The outcomes re similar to those patients who followed a posterior stabilized endoprosthesis.

  5. Joint Motion Quality in Chondromalacia Progression Assessed by Vibroacoustic Signal Analysis.

    Science.gov (United States)

    Bączkowicz, Dawid; Majorczyk, Edyta

    2016-11-01

    Because of the specific biomechanical environment of the patellofemoral joint, chondral disorders, including chondromalacia, often are observed in this articulation. Chondromalacia via pathologic changes in cartilage may lead to qualitative impairment of knee joint motion. To determine the patellofemoral joint motion quality in particular chondromalacia stages and to compare with controls. Retrospective, comparative study. Voivodship hospitals, university biomechanical laboratory. A total of 89 knees with chondromalacia (25 with stage I; 30 with stage II and 34 with stage III) from 50 patients and 64 control healthy knees (from 32 individuals). Vibroacoustic signal pattern analysis of joint motion quality. For all knees vibroacoustic signals were recorded. Each obtained signal was described by variation of mean square, mean range (R4), and power spectral density for frequency of 50-250 Hz (P1) and 250-450 Hz (P2) parameters. Differences between healthy controls and all chondromalacic knees as well as chondromalacia patellae groups were observed as an increase of analyzed parameters (P chondromalacia patellae was found. All chondromalacia groups were differentiated by the use of all analyzed parameters (P chondromalacia. Chondromalacia generates abnormal vibroacoustic signals, and there seems to be a relationship between the level of signal amplitude as well as frequency and cartilage destruction from the superficial layer to the subchondral bone. IV. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  6. Femoropatellar gliding movement during active stretching of the knee

    International Nuclear Information System (INIS)

    Brossmann, J.; Muhle, C.; Melchert, U.H.; Spielmann, R.P.; Schroeder, C.; Hassenpflug, J.

    1992-01-01

    By means of motion-triggered MRT it has been possible for the first time to demonstrate movements in the patello-femoral joint by means of MRT. Patello-femoral movement was studied during active extension of the knee between 30deg flexion and complete extension. The knees of 5 normal females and 7 normal males were studied together with 2 women with recurrent lateral patellar luxation. In normal women there was an average 16deg (10 to 18deg), in men an average of 12deg (10 to 14deg) of lateralisation of the patella during complete extension of the knee. In 1 patient there was 10deg medial displacement of the patella before extension. In 2 knees with recurrent lateral subluxation there was a 20 and 24deg displacement of the patella. (orig.) [de

  7. System analysis of sagittal plane human motion wearing an exoskeleton using marker technology

    Directory of Open Access Journals (Sweden)

    Jatsun Sergey

    2016-01-01

    Full Text Available This paper discusses various methods of obtaining time functions for joint angle that describe a exoskeleton’s motion during sit-to-stand motion. This article demonstrates that functions obtained by solving the inverse kinematics problem can be effectively used as inputs to the control system of the robot. Comparison with experimentally data obtained using marker technology is done.

  8. Radiological imaging of osteoarthritis of the knee

    International Nuclear Information System (INIS)

    Wick, M.C.; Jaschke, W.; Klauser, A.S.

    2012-01-01

    Osteoarthritis is the most common degenerative age-related joint disease leading to typical degradation of articular cartilage with severe pain and limitation of joint motion. Although knee radiographs are widely considered as the gold standard for the assessment of knee osteoarthritis in clinical and scientific settings they increasingly have significant limitations in situations when resolution and assessment of cartilage is required. Analysis of osteoarthritis of the knee with conventional x-ray is associated with many technical limitations and is increasingly being replaced by high-quality assessment using magnetic resonance imaging (MRI) or sonography both in the clinical routine and scientific studies. Novel imaging modalities such as MRI or ultrasound enable in vivo visualization of the quality of the cartilaginous structure and bone as well as all articular and periarticular tissue. Therefore, the limitations of radiographs in assessment of knee osteoarthritis could be overcome by these techniques. This review article aims to provide insights into the most important radiological features of knee osteoarthritis and systematic visualization with different imaging approaches. The demographic development in western industrialized countries predicts an increase of ageing-related osteoarthritis of the knee for the next decades. A systematic radiological evaluation of patients with knee osteoarthritis includes the assessment of the periarticular soft tissue, cartilaginous thickness, cartilage volume, possible cartilage defects, the macromodular network of hyaline cartilage, bone marrow edema, menisci and articular ligaments. Modern imaging modalities, such as MRI and sonography allow the limitations of conventional radiography to be overcome and to visualize the knee structures in great detail to quantitatively assess the severity of knee osteoarthritis. (orig.) [de

  9. Markerless motion capture systems for tracking of persons in forensic biomechanics

    DEFF Research Database (Denmark)

    Yang, Sylvia; Christiansen, Martin S.; Larsen, Peter Kastmand

    2014-01-01

    the postures from a sagittal viewpoint. Although integrating all three dimensions (3D) might improve the results considerably. The purpose of this paper is to give an overview of the 3D multi-view markerless motion capture systems which could be applicable for 3D gait analysis. This paper contains presentation......Markerless motion capture is a pronounced topic in computer vision. In forensic science, markerless motion capture can be an important tool for identification through gait analysis. Recent studies of gait analysis in forensic science have shown that individuals can be identified when analysing...

  10. Kinematic analysis of anterior cruciate ligament reconstruction in total knee arthroplasty

    Science.gov (United States)

    Liu, Hua-Wei; Ni, Ming; Zhang, Guo-Qiang; Li, Xiang; Chen, Hui; Zhang, Qiang; Chai, Wei; Zhou, Yong-Gang; Chen, Ji-Ying; Liu, Yu-Liang; Cheng, Cheng-Kung; Wang, Yan

    2016-01-01

    Background: This study aims to retain normal knee kinematics after knee replacement surgeries by reconstructing anterior cruciate ligament during total knee arthroplasty. Method: We use computational simulation tools to establish four dynamic knee models, including normal knee model, posterior cruciate ligament retaining knee model, posterior cruciate ligament substituting knee model, and anterior cruciate ligament reconstructing knee model. Our proposed method utilizes magnetic resonance images to reconstruct solid bones and attachments of ligaments, and assemble femoral and tibial components according representative literatures and operational specifications. Dynamic data of axial tibial rotation and femoral translation from full-extension to 135 were measured for analyzing the motion of knee models. Findings: The computational simulation results show that comparing with the posterior cruciate ligament retained knee model and the posterior cruciate ligament substituted knee model, reconstructing anterior cruciate ligament improves the posterior movement of the lateral condyle, medial condyle and tibial internal rotation through a full range of flexion. The maximum posterior translations of the lateral condyle, medial condyle and tibial internal rotation of the anterior cruciate ligament reconstructed knee are 15.3 mm, 4.6 mm and 20.6 at 135 of flexion. Interpretation: Reconstructing anterior cruciate ligament in total knee arthroplasty has been approved to be an more efficient way of maintaining normal knee kinematics comparing to posterior cruciate ligament retained and posterior cruciate ligament substituted total knee arthroplasty. PMID:27347334

  11. [Mini-subvastus approach for total knee replacement].

    Science.gov (United States)

    Halder, Andreas; Beier, Alexander; Neumann, Wolfram

    2009-03-01

    Total knee replacement in minimally invasive technique without any trauma to the extensor apparatus and with soft-tissue-referenced bone resections. Only the subvastus approach preserves the integrity of the extensor apparatus and has therefore been modified to become a minimally invasive technique with a shorter skin incision and lateralization instead of eversion of the patella. Soft-tissue balancing is done through this direct anterior approach. Mild to moderate varus osteoarthritis of the knee up to 15 degrees of malalignment, mild and passively correctable valgus osteoarthritis of the knee up to 10 degrees of malalignment. Severe, contract varus osteoarthritis of the knee, severe and moderate, contract valgus osteoarthritis of the knee, severe obesity, exceptionally muscular patients, decreased skin perfusion. Central skin incision from the superior pole of the patella to the tibial tubercle. Exposure of the medial retinaculum and mobilization of the vastus medialis muscle subcutaneously. Incision of the medial retinaculum and blunt separation of the vastus medialis muscle from the intermuscular septum. Lateralization of the patella and flexion of the knee joint. Resection of the tibia perpendicular to the diaphysis. Adjustment of the anteroposterior (AP) resection block at the level of the anterior femoral cortex and of rotation by applying equal tension to the collateral ligaments. Balancing of soft-tissue tension in flexion gap by release, if necessary. After AP resection fixation of distal resection block in planned valgus angle. Balancing of soft-tissue tension in extension gap by release, if necessary. After distal femur resection facet resection, adaptation of posterior femoral condyles, and implantation of prosthesis. Check on stability and range of motion. Wound closure. Full weight bearing from the 1st postoperative day, CPM (continuous passive motion) with up to 90 degrees flexion with peridural anesthesia as tolerated, stair climbing starting on

  12. Meniscal position on routine MR imaging of the knee

    International Nuclear Information System (INIS)

    Miller, T.T.; Staron, R.B.; Feldman, F.; Cepel, E.

    1997-01-01

    Objective. To determine the prevalence of meniscal protrusion (i.e. location of the outer edge of a meniscus beyond the tibial articular surface), and to determine its relationship with internal derangement, joint effusion, and degenerative arthropathy. Design and patients. Sagittal and coronal MR images of 111 abnormal and 46 normal knees were evaluated for the presence of meniscal protrusion. We set 25% as the minimum amount of displacement considered abnormal because this was the smallest amount of displacement we could confidently discern. Presence of meniscal tear, anterior cruciate ligament (ACL) injury, joint effusion, or osteophytosis was also recorded. Results and conclusion. Normal examinations demonstrated protrusion of the medial meniscus in 6.5% of sagittal images and 15% of coronal images, and of the lateral meniscus in 2% and 13%, respectively. Fisher's exact test demonstrated a statistically significant difference between the normal and abnormal groups for the medial meniscus on both sagittal (P 0.2). A protruding medial meniscus was associated with effusion and osteophytosis (P 0.1). Posterior protrusion of the lateral meniscus was only associated with ACL injury (P<0.0001); protruding anterior horns and bodies of lateral menisci were not associated with any of the four abnormalities. It is concluded that the medial meniscus may occasionally protrude more than 25% of its width, but protrusion is more often due to effusion and osteophytes. Protrusion of the posterior horn of the lateral meniscus is associated with ACL insufficiency, while protrusion of the body and anterior horn of the lateral meniscus is a normal variant. (orig.). With 4 figs

  13. Back to the future: sagittal CT in the evaluation of COPD

    International Nuclear Information System (INIS)

    Hightower, Jessica S.; Amadi, Chiemezie; Den, Elana; Schmitt, James E.; Shah, Rosita M.; Miller, Wallace T.

    2016-01-01

    To identify features of obstructive airway disease on sagittal reconstruction, compare the accuracy of findings to traditional imaging characteristics of COPD, and determine the fraction of additional cases identified using new characteristics. The study was approved by the centre's Institutional Review Board and is HIPAA compliant. Two hundred sixteen patients with HRCT and spirometry within a 3-month window were included. Four radiologists evaluated each HRCT for traditional characteristics of COPD and new quantitative and qualitative features of obstruction on axial and sagittal reconstructions. Imaging characteristics were assessed for correlation with the spirometric diagnosis of obstructive airway disease. Quantitative and qualitative findings on sagittal reconstruction are highly specific for COPD (specificity >90 %). Features of hyperinflation on sagittal reconstruction are more accurate predictors of obstruction than traditional axial measures, with greater interobserver reliability (hyperinflation left hemidiaphragm: accuracy: 70.08 % ± 2.49 %; kappa: 0.511 versus traditional measures: accuracy: 62.00 % ± 5.38 %; kappa: 0.407). Sagittal reconstruction identified 27-70 % more patients with COPD than traditional axial findings (p < 0.05). Analysis of sagittal reconstruction enables greater accuracy and specificity in the diagnosis of obstructive airway disease compared to traditional measures on axial imaging. Use of sagittal reconstructions can help identify up to 70 % more patients with COPD than traditional imaging findings alone. (orig.)

  14. The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

    Science.gov (United States)

    Shi, Xiaojun; Shen, Bin; Kang, Pengde; Yang, Jing; Zhou, Zongke; Pei, Fuxing

    2013-12-01

    To evaluate and quantify the effect of the tibial slope on the postoperative maximal knee flexion and stability in the posterior-stabilized total knee arthroplasty (TKA). Fifty-six patients (65 knees) who had undergone TKA with the posterior-stabilized prostheses were divided into the following 3 groups according to the measured tibial slopes: Group 1: ≤4°, Group 2: 4°-7° and Group 3: >7°. The preoperative range of the motion, the change in the posterior condylar offset, the elevation of the joint line, the postoperative tibiofemoral angle and the preoperative and postoperative Hospital for Special Surgery (HSS) scores were recorded. The tibial anteroposterior translation was measured using the Kneelax 3 Arthrometer at both the 30° and the 90° flexion angles. The mean values of the postoperative maximal knee flexion were 101° (SD 5), 106° (SD 5) and 113° (SD 9) in Groups 1, 2 and 3, respectively. A significant difference was found in the postoperative maximal flexion between the 3 groups (P slope resulted in a 1.8° flexion increment (r = 1.8, R (2) = 0.463, P slope can significantly increase the postoperative maximal knee flexion. The tibial slope with an appropriate flexion and extension gap balance during the operation does not affect the joint stability.

  15. Exoskeleton Motion Control for Children Walking Rehabilitation

    Directory of Open Access Journals (Sweden)

    Cristina Ploscaru

    2016-06-01

    Full Text Available This paper introduces a quick method for motion control of an exoskeleton used on children walking rehabilitation with ages between four to seven years old. The exoskeleton used on this purpose has six servomotors which work independently and actuates each human lower limb joints (hips, knees and ankles. For obtaining the desired motion laws, a high-speed motion analysis equipment was used. The experimental rough data were mathematically modeled in order to obtain the proper motion equations for controlling the exoskeleton servomotors.

  16. Outcome of total knee arthroplasty with insall burstein-11 prosthesis

    International Nuclear Information System (INIS)

    Siddiq, M.Z.; Qayum, H.

    2006-01-01

    Patients with severe degenerative knee joint disease often require knee arthroplasty to reduce pain, improve stability and restore function. Insall Burstein II prosthesis is posteriorly stabilized condylar prosthesis, which provide posterior cruciate ligament substitution. It was designed to improve range of motion, stair climbing ability and to prevent posterior subluxation. Evaluate the functional outcome of total knee arthroplasty with IB II prosthesis and Evaluate the alignment of prosthetic components by radiological parameters and its correlation with functional outcome. Sixty knees of sixty patients were replaced by using Insall Burstein II prosthesis. Postoperative radiographs were evaluated for alignment of knee and prosthetic components by criteria selected from knee society roentogenographic evaluation system. Functional outcome was evaluated by rationale of knee society knee rating system. Prosthetic component was aligned in 93% and mal-alignment in 7% of the cases. There was significant improvement in functions core from mean score 33.83 +-15.5 to 59.5+-17.7 and knee score from 37 +- 12.5 to 76.4 +-2.2. Postoperative functional score was found correlated with alignment significantly. Conclusion: Total knee arthroplasty with I-B-II prosthesis is a safe durable and predictable procedure with proper surgical technique and expertise good alignment and satisfactory functional out come can be achieved. (author)

  17. Anthropometric outcome of sagittal craniosynostosis following surgery

    International Nuclear Information System (INIS)

    Takagi, Toshinori; Morota, Nobuhito; Ihara, Satoshi; Kaneko, Tsuyoshi

    2011-01-01

    Several studies have shown good short-term outcomes after surgery for sagittal synostosis. However, the improvement in head shape usually regresses over the long term. The aim of this study was to compare anthropometric changes after surgery between osteoplastic expansion surgery and distraction osteogenesis for correcting sagittal synostosis. From November 2002 through December 2008, 17 patients with sagittal synostosis were analyzed. Anthropometric changes were assessed with cephalic indices obtained with computed tomography of the skull. The age of the patients at the time of surgery ranged from 2 to 25 months (mean, 8.2 months), and the follow-up period ranged from 6 to 63 months (mean, 17 months). In 16 patients, the cephalic index showed improvement immediately after surgery but gradually decreased in the follow-up period. The improving rate was decreased more after osteoplastic expansion surgery than after distraction osteogenesis (p<0.01). Although long-term follow-up is necessary, morphological improvement persists to a greater degree after distraction surgery. (author)

  18. Four Weeks of Mobility After 8 Weeks of Immobility Fails to Restore Normal Motion

    Science.gov (United States)

    Trudel, Guy; Zhou, Jian; Uhthoff, Hans K.

    2008-01-01

    Prolonged immobilization reduces passive range of motion of joints creating joint contractures. Whether and to what extent these iatrogenic contractures can be reduced is unknown. We raised three questions using an animal model: What degree of contracture remains at the end of a defined remobilization period? Do contractures in sham-operated and immobilized joints differ? What is the contribution of the posterior knee capsule in limiting knee extension? We immobilized one knee of 11 adult male rats in flexion to induce a joint contracture; 10 control animals underwent a sham operation. After 8 weeks, the internal fixation device was removed, and the animals were allowed to resume unrestricted activity for 4 weeks at the end of which the knee range of motion was measured with standardized torques. The mean flexion contracture was higher in the immobilized group (51.9° ± 2.8°) than in the sham-operated group (18.9° ± 2.1°). Eighty-eight percent of the contractures remained in the immobilized group after dividing skin and muscle, suggesting an important contribution of the posterior knee capsule in limiting knee mobility. Based on our preliminary study the range of motion of rat knees immobilized for 8 weeks remained substantially reduced after a 4-week period of unassisted remobilization. PMID:18299947

  19. Displacement of the medial meniscus within the passive motion characteristics of the human knee joint: an RSA study in human cadaver knees.

    NARCIS (Netherlands)

    Tienen, T. van; Buma, P.; Scholten, J.G.; Kampen, A. van; Veth, R.P.H.; Verdonschot, N.J.J.

    2005-01-01

    The objective of this study was to validate an in vitro human cadaver knee-joint model for the evaluation of the meniscal movement during knee-joint flexion. The question was whether our model showed comparable meniscal displacements to those found in earlier meniscal movement studies in vivo.

  20. Pedicle subtraction osteotomy in elderly patients with degenerative sagittal imbalance.

    Science.gov (United States)

    Cho, Kyu-Jung; Kim, Ki-Tack; Kim, Whoan-Jeang; Lee, Sang-Hoon; Jung, Jae-Hoon; Kim, Young-Tae; Park, Hae-Bong

    2013-11-15

    Retrospective, radiographical analysis. To evaluate pedicle subtraction osteotomy (PSO) as a means of correcting severe degenerative sagittal imbalance in elderly patients. PSO in patients with degenerative sagittal imbalance is likely to cause more complications than in patients with iatrogenic flatback deformity. This study analyzed 34 patients who underwent fusion to the sacrum, with a minimum 2-year follow-up. Age of the patients were in the range from 58 to 73 with the mean at 65.5 years. PSO was performed at one segment in all cases, consisting of L3 (n = 26), L4 (n = 4), L2 (n = 3), and L1 (n = 1). The average number of levels fused was 8.15. Ten patients had structural interbody fusion at the lumbosacral junction. Applying PSO at one segment, the mean correction of the lordotic angle at the osteotomy site was 33.3°, of which the loss of correction (LOC) was 4.0° at the last visit. The correction of lumbar lordosis was 33.7° and the LOC was 8.5°. The sagittal C7 plumb was 215.9 mm before surgery, corrected to 35.1 mm after surgery, and changed to 95.9 mm by the last visit. The correction of the sagittal C7 plumb was 119.9 mm and the LOC was 60.9 mm. There was substantial LOC in lumbar lordosis and sagittal C7 plumb. In 10 patients with addition of posterior lumbar interbody fusion, the LOC of lumbar lordosis was 7.4°, which was less than 9° in those without it. PSO for the correction of degenerative sagittal imbalance in elderly patients resulted in correction of sagittal alignment with a significant LOC of lumbar lordosis and sagittal C7 plumb. The LOC of lumbar lordosis occurred at both the osteotomy and non-osteotomy site. The addition of anterior column support is helpful to maintain correction and reduce complications. N/A.

  1. In vivo six-degree-of-freedom knee-joint kinematics in overground and treadmill walking following total knee arthroplasty.

    Science.gov (United States)

    Guan, Shanyuanye; Gray, Hans A; Schache, Anthony G; Feller, Julian; de Steiger, Richard; Pandy, Marcus G

    2017-08-01

    No data are available to describe six-degree-of-freedom (6-DOF) knee-joint kinematics for one complete cycle of overground walking following total knee arthroplasty (TKA). The aims of this study were firstly, to measure 6-DOF knee-joint kinematics and condylar motion for overground walking following TKA; and secondly, to determine whether such data differed between overground and treadmill gait when participants walked at the same speed during both tasks. A unique mobile biplane X-ray imaging system enabled accurate measurement of 6-DOF TKA knee kinematics during overground walking by simultaneously tracking and imaging the joint. The largest rotations occurred for flexion-extension and internal-external rotation whereas the largest translations were associated with joint distraction and anterior-posterior drawer. Strong associations were found between flexion-extension and adduction-abduction (R 2  = 0.92), joint distraction (R 2  = 1.00), and anterior-posterior translation (R 2  = 0.77), providing evidence of kinematic coupling in the TKA knee. Although the measured kinematic profiles for overground walking were grossly similar to those for treadmill walking, several statistically significant differences were observed between the two conditions with respect to temporo-spatial parameters, 6-DOF knee-joint kinematics, and condylar contact locations and sliding. Thus, caution is advised when making recommendations regarding knee implant performance based on treadmill-measured knee-joint kinematic data. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1634-1643, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  2. The influence of a powered knee-ankle-foot orthosis on walking in poliomyelitis subjects: A pilot study.

    Science.gov (United States)

    Arazpour, Mokhtar; Moradi, Alireza; Samadian, Mohammad; Bahramizadeh, Mahmood; Joghtaei, Mahmoud; Ahmadi Bani, Monireh; Hutchins, Stephen W; Mardani, Mohammad A

    2016-06-01

    Traditionally, the anatomical knee joint is locked in extension when walking with a conventional knee-ankle-foot orthosis. A powered knee-ankle-foot orthosis was developed to provide restriction of knee flexion during stance phase and active flexion and extension of the knee during swing phase of gait. The purpose of this study was to determine differences of the powered knee-ankle-foot orthosis compared to a locked knee-ankle-foot orthosis in kinematic data and temporospatial parameters during ambulation. Quasi-experimental design. Subjects with poliomyelitis (n = 7) volunteered for this study and undertook gait analysis with both the powered and the conventional knee-ankle-foot orthoses. Three trials per orthosis were collected while each subject walked along a 6-m walkway using a calibrated six-camera three-dimensional video-based motion analysis system. Walking with the powered knee-ankle-foot orthosis resulted in a significant reduction in both walking speed and step length (both 18%), but a significant increase in stance phase percentage compared to walking with the conventional knee-ankle-foot orthosis. Cadence was not significantly different between the two test conditions (p = 0.751). There was significantly higher knee flexion during swing phase and increased hip hiking when using the powered orthosis. The new powered orthosis permitted improved knee joint kinematic for knee-ankle-foot orthosis users while providing knee support in stance and active knee motion in swing in the gait cycle. Therefore, the new powered orthosis provided more natural knee flexion during swing for orthosis users compared to the locked knee-ankle-foot orthosis. This orthosis has the potential to improve knee joint kinematics and gait pattern in poliomyelitis subjects during walking activities. © The International Society for Prosthetics and Orthotics 2015.

  3. An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data.

    OpenAIRE

    Breen, Alan C.; Muggleton, J.M.; Mellor, F.E.

    2006-01-01

    Abstract Background Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing. Methods Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptom...

  4. ACL Injury Prevention Training Results in Modification of Hip and Knee Mechanics During a Drop-Landing Task.

    Science.gov (United States)

    Pollard, Christine D; Sigward, Susan M; Powers, Christopher M

    2017-09-01

    Injury prevention training has been shown to be effective in reducing the incidence of noncontact anterior cruciate ligament (ACL) injury; however, the underlying reason for the success of these training programs is unclear. To investigate whether an ACL injury prevention program that has been shown to reduce the incidence of ACL injury alters sagittal plane hip and knee biomechanics during a drop-landing task. Descriptive laboratory study. Thirty female club soccer players (age range, 11-17 years) with no history of knee injury participated in this study. Kinematics and ground-reaction forces were collected while each participant performed a drop-landing task prior to and immediately after participation in a 12-week ACL injury prevention training program. After ACL injury prevention training, participants demonstrated decreased knee extensor moments ( P = .03), increased energy absorption at the hip ( P = .04), decreased knee-to-hip extensor moment ratios ( P = .05), and decreased knee-to-hip energy absorption ratios ( P = .03). Participation in an ACL injury prevention training program decreased reliance on the knee extensor muscles and improved use of the hip extensor muscles, which may explain the protective effect of this type of training program on ACL injury. Based on these findings, clinicians can better understand how ACL injury prevention training, such as the Prevent Injury and Enhance Performance (PEP) Program, may change movement behavior at both the hip and knee. Furthermore, the study findings may support the implementation of the PEP Program, or a similar program, for clinicians aiming to improve use of the hip in an effort to reduce knee loading and consequent injuries.

  5. A Computer Navigation System Analysis of the Accuracy of the Extramedullary (Tibial Alignment Technique in Total Knee Arthroplasty (TKA

    Directory of Open Access Journals (Sweden)

    EK Chee

    2010-07-01

    Full Text Available In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to analyse the accuracy of an extramedullary (tibial alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial jig placement, in either the coronal and sagittal planes or both planes. The results showed that the accuracy of the extramedullary tibial alignment system, in the coronal plane (in up to 80-87% of cases was much better than for posterior slope, and sagittal plane. Surgeon experience was not a significant factor.

  6. Comparison of Joint Loading in Badminton Lunging between Professional and Amateur Badminton Players

    Directory of Open Access Journals (Sweden)

    Lin Fu

    2017-01-01

    Full Text Available The knee and ankle are the two most injured joints associated with the sport of badminton. This study evaluates biomechanical factors between professional and amateur badminton players using an injury mechanism model. The aim of this study was to investigate the kinematic motion and kinetic loading differences of the right knee and ankle while performing a maximal right lunge. Amateur players exhibited greater ankle range of motion (p<0.05, r=0.89 and inversion joint moment (p<0.05, r=0.54 in the frontal plane as well as greater internal joint rotation moment (p<0.05, r=0.28 in the horizontal plane. In contrast, professional badminton players presented a greater knee joint moment in the sagittal (p<0.05, r=0.59 and frontal (p<0.05, r=0.37 planes, which may be associated with increased knee ligamentous injury risk. To avoid injury, the players need to forcefully extend the knee with internal rotation, strengthen the muscles around the ankle ligament, and maximise joint coordination during training. The injuries recorded and the forces responsible for the injuries seem to have developed during training activity. Training programmes and injury prevention strategies for badminton players should account for these findings to reduce potential injury to the ankle and knee.

  7. A rotary pneumatic actuator for the actuation of the exoskeleton knee joint

    Directory of Open Access Journals (Sweden)

    Jobin Varghese

    2017-07-01

    Full Text Available Rotary pneumatic actuators that are made out of linear one are always best suited for exoskeleton joint actuation due to its inherent power to weight ratio. This work is a modified version of knee actuation system that has already been developed and major modifications are made in order to make it more suitable for human wearing and also to reduce its bulkiness and complexity. The considered actuator system is a rotary actuator where a pulley converts the linear motion of the standard pneumatic piston into the rotary motion. To prove the capability of the actuator, its performance characteristics such as torque and power produced are compared to the required torque and power at the knee joint of the exoskeleton in swing phase and are found to be excellent. The two-way analysis of variance (ANOVA is performed to find the effect of the throat area valve on knee angle. The ANOVA shows the significant effect of the throat area variation on the knee angle flexion made by the proposed actuator. A relationship between the throat area of flow control valve, that is connected to the exit port of the direction control valve, and angular displacement of the knee joint has been formulated. This relationship can be used to design a control system to regulate the mass flow rate of air at the exit and hence the angular velocity of the knee joint can be controlled. Keywords: Driven pulley, Flow control valve, Rotary, Pneumatic cylinder

  8. Gear Shifting of Quadriceps during Isometric Knee Extension Disclosed Using Ultrasonography.

    Science.gov (United States)

    Zhang, Shu; Huang, Weijian; Zeng, Yu; Shi, Wenxiu; Diao, Xianfen; Wei, Xiguang; Ling, Shan

    2018-01-01

    Ultrasonography has been widely employed to estimate the morphological changes of muscle during contraction. To further investigate the motion pattern of quadriceps during isometric knee extensions, we studied the relative motion pattern between femur and quadriceps under ultrasonography. An interesting observation is that although the force of isometric knee extension can be controlled to change almost linearly, femur in the simultaneously captured ultrasound video sequences has several different piecewise moving patterns. This phenomenon is like quadriceps having several forward gear ratios like a car starting from rest towards maximal voluntary contraction (MVC) and then returning to rest. Therefore, to verify this assumption, we captured several ultrasound video sequences of isometric knee extension and collected the torque/force signal simultaneously. Then we extract the shapes of femur from these ultrasound video sequences using video processing techniques and study the motion pattern both qualitatively and quantitatively. The phenomenon can be seen easier via a comparison between the torque signal and relative spatial distance between femur and quadriceps. Furthermore, we use cluster analysis techniques to study the process and the clustering results also provided preliminary support to the conclusion that, during both ramp increasing and decreasing phases, quadriceps contraction may have several forward gear ratios relative to femur.

  9. A morphometric investigation on breed-specific features affecting sagittal rotational and lateral bending mobility in the canine cervical spine (c3-c7).

    Science.gov (United States)

    Breit, S; Künzel, W

    2004-08-01

    Vertebral and inter-vertebral parameters obtained in large breeds (n = 74), small breeds (n = 35), and Dachshunds (n = 30) were compared to reveal potential differences in the range of motion of the cervical spine between these three groups of breeds. Body size normalized dimensions of vertebral and inter-vertebral parameters and correlations between these indicate large canine breeds to have a tendency towards higher range of motion in sagittal rotation and lateral bending compared with Dachshunds and small breeds. Higher mobility in large breeds is based on significantly (P inter-vertebral discs, wider but shorter cranial and caudal articular surfaces, larger differences in width between caudal and cranial joining facets (compared with Dachshunds from C3/4 to C6/7, compared with small breeds from C4/5 to C5/6), and larger differences in length between caudal and cranial joining facets. Large differences in width between caudal and cranial joining facets were associated with small distances between the most medial (C3/4 to C6/7) and lateral (C3/4 to C5/6) aspects of the articular surfaces as well as with small differences in length between caudal and cranial joining facets (C3/4 to C5/6). This suggests that from C3/4 to C5/6 a higher range of motion in lateral bending is coupled to a lower range of motion in sagittal rotation. The present findings contribute also to explain the higher incidence of degenerative lesions of the cervical spine in large dogs.

  10. The association between reduced knee joint proprioception and medial meniscal abnormalities using MRI in knee osteoarthritis: results from the Amsterdam osteoarthritis cohort.

    Science.gov (United States)

    van der Esch, M; Knoop, J; Hunter, D J; Klein, J-P; van der Leeden, M; Knol, D L; Reiding, D; Voorneman, R E; Gerritsen, M; Roorda, L D; Lems, W F; Dekker, J

    2013-05-01

    Osteoarthritis (OA) of the knee is characterized by pain and activity limitations. In knee OA, proprioceptive accuracy is reduced and might be associated with pain and activity limitations. Although causes of reduced proprioceptive accuracy are divergent, medial meniscal abnormalities, which are highly prevalent in knee OA, have been suggested to play an important role. No study has focussed on the association between proprioceptive accuracy and meniscal abnormalities in knee OA. To explore the association between reduced proprioceptive accuracy and medial meniscal abnormalities in a clinical sample of knee OA subjects. Cross-sectional study in 105 subjects with knee OA. Knee proprioceptive accuracy was assessed by determining the joint motion detection threshold in the knee extension direction. The knee was imaged with a 3.0 T magnetic resonance (MR) scanner. Number of regions with medial meniscal abnormalities and the extent of abnormality in the anterior and posterior horn and body were scored according to the Boston-Leeds Osteoarthritis Knee Score (BLOKS) method. Multiple regression analyzes were used to examine whether reduced proprioceptive accuracy was associated with medial meniscal abnormalities in knee OA subjects. Mean proprioceptive accuracy was 2.9° ± 1.9°. Magnetic resonance imaging (MRI)-detected medial meniscal abnormalities were found in the anterior horn (78%), body (80%) and posterior horn (90%). Reduced proprioceptive accuracy was associated with both the number of regions with meniscal abnormalities (P knee complaints. This is the first study showing that reduced proprioceptive accuracy is associated with medial meniscal abnormalities in knee OA. The study highlights the importance of meniscal abnormalities in understanding reduced proprioceptive accuracy in persons with knee OA. Copyright © 2013 Osteoarthritis Research Society International. All rights reserved.

  11. Unicompartmental knee arthroplasty for spontaneous osteonecrosis of the knee: A meta-analysis.

    Science.gov (United States)

    Jauregui, Julio J; Blum, Christopher L; Sardesai, Neil; Bennett, Craig; Henn, R Frank; Adib, Farshad

    2018-01-01

    Spontaneous osteonecrosis of the knee (SONK) is a poorly understood but debilitating disease entity. Total knee arthroplasty (TKA) is the standard of care for those patients who fail conservative management, but considering SONK's predilection for affecting a single knee compartment, unicompartmental knee arthroplasty (UKA) appears to be a more tailored option. Unfortunately, conflicting data exist on the utility of UKA in SONK. Thus, the purpose of this study was to evaluate functional outcomes and revision rates of UKA in the setting of SONK. A systematic literature search was performed to evaluate all studies examining patients who underwent UKA for SONK. Screening of the articles was performed using multiple Boolean search strings, methodological index for non-randomized studies criteria, and other selected exclusion criteria. Seven studies were included, with a total of 276 knees (273 patients). The mean age was 68 years (64-74 years), with a mean body mass index of 26 kg/m 2 (25-29 kg/m 2 ). The final range of motion was 125° (124-126°). Standardized mean difference (SMD) of clinical improvement pre- and post-outcome was 3.39 ( p < 0.001). The improvement in the visual analog score was 57.03 points, with an SMD of 4.57 ( p < 0.001). Revision rates were determined to be 5.51% (95% confidence interval of 1.96-10.69%). Our meta-analysis demonstrated that in properly selected patients, UKA could be an excellent alternative to TKA for patients with SONK. These data show that UKA has few complications, significant improvements on functional outcomes, and good survivorship at a mean follow-up of 6 years.

  12. Lenke 1 and 5: changes in sagittal balance

    Directory of Open Access Journals (Sweden)

    Delson Valdemir Pessin

    2014-09-01

    Full Text Available OBJECTIVE: To assess in a cross-sectional study whether there are changes in sagittal balance in patients with adolescent idiopathic scoliosis Lenke types 1 and 5 compared with patients without pathology of the spine and compare the values of the parameters of normal subjects with the parameters found in the literature. METHODS: We measured the values of the parameters of sagittal balance of 21 patients with scoliosis and 14 patients without scoliosis in panoramic radiographs or simply collected data previously measured from the medical records. We compared the mean values of normal subjects, the mean values found in the literature, and the means between normal subjects and patients with scoliosis. For this, we used the Student t test. RESULTS: Using a confidence interval of 5% (p < 0.05 and the Student t test we obtained statistical significance in the comparison of two parameters of sagittal balance between normal subjects and patients with scoliosis. We observed similarities in the measurements of the average parameters of normal subjects with regard to the work already published. CONCLUSIONS: The adolescent idiopathic scoliosis causes changes in two parameters of sagittal balance with statistical significance but suggests changes in all other parameters. As for comparison with previously published work, the results were similar.

  13. Contributions of biarticular myogenic components to the limitation of the range of motion after immobilization of rat knee joint

    Science.gov (United States)

    2014-01-01

    Background Muscle atrophy caused by immobilization in the shortened position is characterized by a decrease in the size or cross-sectional area (CSA) of myofibers and decreased muscle length. Few studies have addressed the relationship between limitation of the range of motion (ROM) and the changes in CSA specifically in biarticular muscles after atrophy because of immobilization. We aimed to determine the contribution of 2 distinct muscle groups, the biarticular muscles of the post thigh (PT) and those of the post leg (PL), to the limitation of ROM as well as changes in the myofiber CSAs after joint immobilization surgery. Methods Male Wistar rats (n = 40) were randomly divided into experimental and control groups. In the experimental group, the left knee was surgically immobilized by external fixation for 1, 2, 4, 8, or 16 weeks (n = 5 each) and sham surgery was performed on the right knee. The rats in the control groups (n = 3 per time point) did not undergo surgery. After the indicated immobilization periods, myotomy of the PT or PL biarticular muscles was performed and the ROM was measured. The hamstrings and gastrocnemius muscles from the animals operated for 1 or 16 weeks were subjected to morphological analysis. Results In immobilized knees, the relative contribution of the PT biarticular myogenic components to the total restriction reached 80% throughout the first 4 weeks and decreased thereafter. The relative contribution of the PL biarticular myogenic components remained contracture did not significantly change during the experimental period. However, the ratio of hamstrings CSAs to the sham side was larger than the ratio of medial gastrocnemius CSAs to the sham side after complete atrophy because of immobilization. PMID:25001065

  14. Young Athletes After Anterior Cruciate Ligament Reconstruction With Single-Leg Landing Asymmetries at the Time of Return to Sport Demonstrate Decreased Knee Function 2 Years Later.

    Science.gov (United States)

    Ithurburn, Matthew P; Paterno, Mark V; Ford, Kevin R; Hewett, Timothy E; Schmitt, Laura C

    2017-09-01

    Previous work shows that young athletes after anterior cruciate ligament reconstruction (ACLR) demonstrate single-leg (SL) landing movement asymmetries at the time of return to sport (RTS); however, the effect of movement asymmetries on longitudinal knee-related function after ACLR has not been examined. Hypothesis/Purpose: The purpose of this study was to examine the effect of SL drop-landing movement symmetry at the time of RTS on knee-related function 2 years later in young athletes after ACLR. The first hypothesis was that young athletes who demonstrated SL drop-landing asymmetries at RTS would demonstrate decreased knee function 2 years later compared with those who demonstrated symmetric SL drop-landing mechanics. The second hypothesis was that SL drop-landing movement symmetry at RTS would be associated with knee functional recovery 2 years later. Cohort study; Level of evidence, 2. This study included 48 young athletes who had undergone ACLR and were assessed at the time of RTS (77% female; mean [±SD] age at RTS, 17.6 ± 2.6 years) and followed for 2 years after RTS. Three sagittal-plane landing variables of interest were calculated using 3-dimensional motion analysis during an SL drop-landing task at the time of RTS: knee flexion excursion, peak internal knee extension moment, and peak trunk flexion. The limb symmetry index (LSI) was calculated for each landing variable using the following: LSI = (involved/uninvolved) × 100%. The LSI was used to divide the cohort into symmetric (SYM) and asymmetric (ASYM) groups for each landing variable: knee flexion excursion (SYM: LSI ≥ 90% [n = 23]; ASYM: LSI 115% [n = 19]). At 2 years after RTS, knee-related function was evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC) subjective knee form, and performance on SL hop tests. Functional recovery was defined based on literature cutoffs for knee-related functional measures. Differences in 2-year

  15. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    International Nuclear Information System (INIS)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji; Niitsu, Mamoru; Itai, Yuji

    2000-01-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  16. T1-weighted vs. short-TE-long-TR images. Usefulness for knee MR examinations of ligament and meniscal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Endo, Hideho; Wada, Mitsuyoshi; Shiotani, Seiji [Tsukuba Medical Center Hospital, Ibaraki (Japan); Niitsu, Mamoru; Itai, Yuji

    2000-11-01

    The purpose of this study was to compare short-TE-long-TR images with T1-weighed images in knee MR examinations. Sagittal MR images of the knee were obtained in 31 patients with knee pain. T1-weighted images were obtained by the spin-echo technique (TR/TE =350/15), and short-TE-long-TR images by fast spin-echo (TR/TE =1300/15) with an echo-train length of 5. Contrast-to-noise-ratios (CNRs) of the anterior cruciate ligament and synovial space, meniscus and articular cartilage, and meniscal lesion and normal meniscus were compared between short-TE-long-TR images and T1-weighted images. On each of the three examinations, short-TE-long-TR images provided significantly higher CNRs than T1-weighted images. It was concluded that short-TE-long-TR images can be a useful alternative to T1-weighted images in evaluating the anterior cruciate ligament and meniscal lesions. (author)

  17. Characterizing head motion in three planes during combined visual and base of support disturbances in healthy and visually sensitive subjects.

    Science.gov (United States)

    Keshner, E A; Dhaher, Y

    2008-07-01

    Multiplanar environmental motion could generate head instability, particularly if the visual surround moves in planes orthogonal to a physical disturbance. We combined sagittal plane surface translations with visual field disturbances in 12 healthy (29-31 years) and 3 visually sensitive (27-57 years) adults. Center of pressure (COP), peak head angles, and RMS values of head motion were calculated and a three-dimensional model of joint motion was developed to examine gross head motion in three planes. We found that subjects standing quietly in front of a visual scene translating in the sagittal plane produced significantly greater (pplane of platform motion significantly increased (phistory of vestibular disorder produced large, delayed compensatory head motion. Orthogonal head motions were significantly greater in visually sensitive than in healthy subjects in the dark (pplanes orthogonal to the direction of a physical perturbation. These results suggest that the mechanisms controlling head orientation in space are distinct from those that control trunk orientation in space. These behaviors would have been missed if only COP data were considered. Data suggest that rehabilitation training can be enhanced by combining visual and mechanical perturbation paradigms.

  18. Circuit training enhances function in patients undergoing total knee arthroplasty: a retrospective cohort study.

    Science.gov (United States)

    Hsu, Wei-Hsiu; Hsu, Wei-Bin; Shen, Wun-Jer; Lin, Zin-Rong; Chang, Shr-Hsin; Hsu, Robert Wen-Wei

    2017-10-19

    The number of patients receiving total knee arthroplasty (TKA) has been rising every year due to the aging population and the obesity epidemic. Post-operative rehabilitation is important for the outcome of TKA. A series of 34 patients who underwent primary unilateral TKA was retrospectively collected and divided into either exercise group (n = 16) and control group (n = 18). The exercise group underwent a 24-week course of circuit training beginning 3 months after total knee arthroplasty (TKA). The effect of circuit training on TKA patients in terms of motion analysis, muscle strength testing, Knee injury and Osteoarthritis Outcomes Score (KOOS) questionnaire and patient-reported outcome measurement Short-Form Health Survey (SF-36) at the pre-operation, pre-exercise, mid-exercise, and post-exercise. Motion analysis revealed the stride length, step velocity, and excursion of active knee range of motion significantly improved in the exercise group when compared to those in the control group. KOOS questionnaire showed a greater improvement in pain, ADL, and total scores in the exercise group. The SF-36 questionnaire revealed a significant improvement in general health, bodily pain, social function, and physical components score in the exercise group. The post-operative circuit training intervention can facilitate recovery of knee function and decrease the degree of pain in the TKA and might be considered a useful adjunct rehabilitative modality. The ultimate influence of circuit training on TKA needs further a prospective randomized clinical trial study and long-term investigation. NCT02928562.

  19. Direct coronary and sagittal computerized tomography of the pelvis

    International Nuclear Information System (INIS)

    Maier, W.; Bargon, G.

    1981-01-01

    Whereas quite a number of reports have been published on direct coronary and sagittal computed tomography of the cranium, no extensive experience has been collected on multidimensional computerized tomography of the pelvis. In this article, the authors report on their preliminary experiences in direct approximately sagittal and coronary computerized tomography of the pelvis in a group of 76 patients. (orig.) [de

  20. Spinal Schmorl's nodes: Sagittal sectional imaging and pathological examination

    International Nuclear Information System (INIS)

    Silberstein, M.; Opeskin, K.

    1999-01-01

    The presence, location and number of Schmorl's nodes was determined in the thoracolumbar spines of 70 motor vehicle accident victims using radiographic examination of a midline sagittal section and subsequent pathological examinations, including histology. In 28% of spines, a greater number of Schmorl's nodes were identified with radiography, while in 44%, pathological examination revealed a greater number of nodes. The visibility of Schmorl's nodes was enhanced by using a sagittal radiographic approach, and, in contrast to previous work, nodes below 0.5 cm 2 were readily detected. The results of the present study offer an additional imaging technique for postmortem analysis of the spine, and support the use of sagittal MR imaging for the evaluation of this condition. Copyright (1999) Blackwell Science Pty Ltd

  1. Sagittal spinal balance after lumbar spinal fusion: the impact of anterior column support results from a randomized clinical trial with an eight- to thirteen-year radiographic follow-up.

    Science.gov (United States)

    Videbaek, Tina S; Bünger, Cody E; Henriksen, Mads; Neils, Egund; Christensen, Finn B

    2011-02-01

    Randomized clinical trial. To analyze the long-term clinical impact of anterior column support on sagittal balance after lumbar spinal fusion. Several investigators have stressed the importance of maintaining sagittal balance in relation to spinal fusion to avoid lumbar 'flat back,' accelerated adjacent segment degeneration, pain, and inferior functional outcome. Only limited evidence exists on how sagittal alignment affects clinical outcome. Anterior lumbar interbody fusion combined with posterolateral fusion has been proved superior to posterolateral fusion alone regarding outcome and cost-effectiveness. No randomized controlled trial has been published analyzing the effect of anterior support on radiographic measurements of sagittal balance. Between 1996 and 1999, 148 patients with severe chronic low back pain were randomly selected for posterolateral lumbar fusion plus anterior support (PLF + ALIF) or posterolateral lumbar fusion. A total of 92 patients participated. Sagittal balance parameters were examined on full lateral radiographs of the spine: pelvic incidence (PI), pelvic tilt (PT), sacral slope, thoracic kyphosis, lumbar lordosis, and positioning of C7 plumb line. The type of lumbar lordosis was evaluated and outcome assessed by Oswestry Disability Index (ODI). Follow-up rate was 74%. Sagittal balance parameters were similar between randomization groups. None of the parameters differed significantly between patients with an ODI from 0 to 40 and patients with ODI over 40. Balanced patients had a significantly superior outcome as measured by ODI (P Lumbar lordosis and type of lordosis correlated with outcome but could not explain the superior outcome in the group with anterior support. Whether sagittal balance and anterior support during fusion provide a protective effect on adjacent motion segments remains unclear.

  2. Test-retest reliability of knee kinematics measurement during gait ...

    African Journals Online (AJOL)

    ACLR) is crucial to minimize the risk of joint degeneration. To achieve this, it is essential that the chosen measurement method can accurately assess knee kinematics and detect the changes in multi-planes of motion. However to date, limited ...

  3. Kinematic and kinetic analysis of the knee joint before and after a PCL retaining total knee replacement during gait and single step ascent.

    Science.gov (United States)

    Apostolopoulos, Alexandros; Lallos, Stergios; Mastrokalos, Dimitrios; Michos, Ioannis; Darras, Nikolaos; Tzomaki, Magda; Efstathopoulos, Nikolaos

    2011-01-01

    The objective of this study was to capture and analyze the kinetics and kinematics and determine the functional performance of the osteoarthritic knee after a posterior cruciate ligament (PCL) retaining total knee arthroplasty. Kinematic and kinetic gait analysis of level walking was performed in 20 subjects (12 female and 8 male) with knee ostoarthritis. These patients were free of any neurological diseases that could affect their normal gait. Mean age was 69.6 ± 6.6 years; mean height was 157.6 cm ± 7.6 cm; and mean weight was 77.2 ± 12.1 kg. Full body gait analyses were performed using the BIOKIN 3D motion analysis system before and 9 months after total knee arthroplasty procedures. Single-step ascending kinetic analyses and plantar pressure distribution analyses were also performed for all subjects. International Knee Society Scores (IKSSs) were also assessed pre- and postoperatively. Significant increases were noted postoperatively in average cadence (preoperative mean = 99.26, postoperative mean = 110.5; p knee adduction moment were also reported postoperatively. All patients showed a significant improvement of knee kinetics and kinematics after a PCL retaining total knee arthroplasty. Significant differences were found in the cadence, step length, stride length, and walk velocity postoperatively. IKSSs also significantly improved. Further research is warranted to determine the clinical relevance of these findings.

  4. Elimination of motion and pulsation artifacts using BLADE sequences in shoulder MR imaging

    International Nuclear Information System (INIS)

    Lavdas, E.; Zaloni, E.; Vlychou, M.; Vassiou, K.; Fezoulidis, I.; Tsagkalis, A.; Dailiana, Z.

    2015-01-01

    To evaluate the ability of proton-density with fat-suppression BLADE (proprietary name for periodically rotated overlapping parallel lines with enhanced reconstruction in MR systems from Siemens Healthcare, PDFS BLADE) and turbo inversion recovery magnitude-BLADE (TIRM BLADE) sequences to reduce motion and pulsation artifacts in shoulder magnetic resonance examinations. Forty-one consecutive patients who had been routinely scanned for shoulder examination participated in the study. The following pairs of sequences with and without BLADE were compared: (a) Oblique coronal proton-density sequence with fat saturation of 25 patients and (b) oblique sagittal T2 TIRM-weighed sequence of 20 patients. Qualitative analysis was performed by two experienced radiologists. Image motion and pulsation artifacts were also evaluated. In oblique coronal PDFS BLADE sequences, motion artifacts have been significantly eliminated, even in five cases of non-diagnostic value with conventional imaging. Similarly, in oblique sagittal T2 TIRM BLADE sequences, image quality has been improved, even in six cases of non-diagnostic value with conventional imaging. Furthermore, flow artifacts have been improved in more than 80% of all the cases. The use of BLADE sequences is recommended in shoulder imaging, especially in uncooperative patients because it effectively eliminates motion and pulsation artifacts. (orig.)

  5. Knee joint stiffness in individuals with and without knee osteoarthritis: a preliminary study.

    Science.gov (United States)

    Oatis, Carol A; Wolff, Edward F; Lennon, Sandra K

    2006-12-01

    Descriptive, case-matched comparison. To compare the knee joint stiffness and damping coefficients of individuals with knee osteoarthritis (KOA) to those of age- and gender-matched individuals without KOA. A secondary purpose was to investigate relationships between these coefficients and complaints of stiffness in individuals with KOA. KOA is a leading cause of disability, and stiffness is a common complaint in individuals with KOA. Yet the most common method of assessing knee joint stiffness is through a self-report questionnaire. Stiffness and damping coefficients at the knee were calculated in 10 volunteers (mean age +/- SD, 64.1+/-15.5 years) with KOA and compared to coefficients from age-and gender-matched individuals without KOA, collected in a previous study (mean age +/- SD, 62.1+/-13.9 years). Stiffness and damping coefficients were calculated from the angular motion of the knee during a relaxed oscillation. Spearman correlation coefficients were calculated between stiffness and damping coefficients and WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index) scores for subjects with KOA. Independent 2-tailed t tests revealed significantly larger damping coefficients (P = .035) among those with KOA (95% CI, 0.10-2.32 Nm s/rad). Spearman rank correlations revealed a significant positive relationship (r = .85, P = .003) between the damping coefficient and the stiffness subscore of the WOMAC. This study offers preliminary data demonstrating the feasibility of measuring stiffness and damping coefficients in individuals with KOA. Additionally, the damping coefficient is increased in people with KOA when compared to age- and gender-matched individuals without KOA. The damping coefficient appears to be associated with the complaints of stiffness reported by the WOMAC.

  6. Estimation of vertical ground reaction forces and sagittal knee kinematics during running using three inertial sensors

    NARCIS (Netherlands)

    Wouda, Frank J.; Giuberti, Matteo; Bellusci, Giovanni; Maartens, Erik; Reenalda, Jasper; van Beijnum, Bernhard J.F.; Veltink, Peter H.

    2018-01-01

    Analysis of running mechanics has traditionally been limited to a gait laboratory using either force plates or an instrumented treadmill in combination with a full-body optical motion capture system. With the introduction of inertial motion capture systems, it becomes possible to measure kinematics

  7. Assessment of patient functional performance in different knee arthroplasty designs during unconstrained squat.

    Science.gov (United States)

    Verdini, Federica; Zara, Claudio; Leo, Tommaso; Mengarelli, Alessandro; Cardarelli, Stefano; Innocenti, Bernardo

    2017-01-01

    In this paper, squat named by Authors unconstrained because performed without constrains related to feet position, speed, knee maximum angle to be reached, was tested as motor task revealing differences in functional performance after knee arthroplasty. It involves large joints ranges of motion, does not compromise joint safety and requires accurate control strategies to maintain balance. Motion capture techniques were used to study squat on a healthy control group (CTR) and on three groups, each characterised by a specific knee arthroplasty design: a Total Knee Arthroplasty (TKA), a Mobile Bearing and a Fixed Bearing Unicompartmental Knee Arthroplasty (respectively MBUA and FBUA). Squat was analysed during descent, maintenance and ascent phase and described by speed, angular kinematics of lower and upper body, the Center of Pressure (CoP) trajectory and muscle activation timing of quadriceps and biceps femoris. Compared to CTR, for TKA and MBUA knee maximum flexion was lower, vertical speed during descent and ascent reduced and the duration of whole movement was longer. CoP mean distance was higher for all arthroplasty groups during descent as higher was, CoP mean velocity for MBUA and TKA during ascent and descent. Unconstrained squat is able to reveal differences in the functional performance among control and arthroplasty groups and between different arthroplasty designs. Considering the similarity index calculated for the variables showing statistically significance, FBUA performance appears to be closest to that of the CTR group. III a.

  8. Assessment of patient functional performance in different knee arthroplasty designs during unconstrained squat

    Science.gov (United States)

    Verdini, Federica; Zara, Claudio; Leo, Tommaso; Mengarelli, Alessandro; Cardarelli, Stefano; Innocenti, Bernardo

    2017-01-01

    Summary Background In this paper, squat named by Authors unconstrained because performed without constrains related to feet position, speed, knee maximum angle to be reached, was tested as motor task revealing differences in functional performance after knee arthroplasty. It involves large joints ranges of motion, does not compromise joint safety and requires accurate control strategies to maintain balance. Methods Motion capture techniques were used to study squat on a healthy control group (CTR) and on three groups, each characterised by a specific knee arthroplasty design: a Total Knee Arthroplasty (TKA), a Mobile Bearing and a Fixed Bearing Unicompartmental Knee Arthroplasty (respectively MBUA and FBUA). Squat was analysed during descent, maintenance and ascent phase and described by speed, angular kinematics of lower and upper body, the Center of Pressure (CoP) trajectory and muscle activation timing of quadriceps and biceps femoris. Results Compared to CTR, for TKA and MBUA knee maximum flexion was lower, vertical speed during descent and ascent reduced and the duration of whole movement was longer. CoP mean distance was higher for all arthroplasty groups during descent as higher was, CoP mean velocity for MBUA and TKA during ascent and descent. Conclusions Unconstrained squat is able to reveal differences in the functional performance among control and arthroplasty groups and between different arthroplasty designs. Considering the similarity index calculated for the variables showing statistically significance, FBUA performance appears to be closest to that of the CTR group. Level of evidence III a. PMID:29387646

  9. Roller-massager application to the quadriceps and knee-joint range of motion and neuromuscular efficiency during a lunge.

    Science.gov (United States)

    Bradbury-Squires, David J; Noftall, Jennifer C; Sullivan, Kathleen M; Behm, David G; Power, Kevin E; Button, Duane C

    2015-02-01

    Roller massagers are used as a recovery and rehabilitative tool to initiate muscle relaxation and improve range of motion (ROM) and muscular performance. However, research demonstrating such effects is lacking. To determine the effects of applying a roller massager for 20 and 60 seconds on knee-joint ROM and dynamic muscular performance. Randomized controlled clinical trial. University laboratory. Ten recreationally active men (age = 26.6 ± 5.2 years, height = 175.3 ± 4.3 cm, mass = 84.4 ± 8.8 kg). Participants performed 3 randomized experimental conditions separated by 24 to 48 hours. In condition 1 (5 repetitions of 20 seconds) and condition 2 (5 repetitions of 60 seconds), they applied a roller massager to the quadriceps muscles. Condition 3 served as a control condition in which participants sat quietly. Visual analog pain scale, electromyography (EMG) of the vastus lateralis (VL) and biceps femoris during roller massage and lunge, and knee-joint ROM. We found no differences in pain between the 20-second and 60-second roller-massager conditions. During 60 seconds of roller massage, pain was 13.5% (5.7 ± 0.70) and 20.6% (6.2 ± 0.70) greater at 40 seconds and 60 seconds, respectively, than at 20 seconds (P joint ROM was 10% and 16% greater in the 20-second and 60-second roller-massager conditions, respectively, than the control condition (P joint ROM and neuromuscular efficiency during a lunge.

  10. Analysing the Hydraulic Actuator-based Knee Unit Kinematics and Correlating the Numerical Results and Walking Human Knee Joint Behavior

    Directory of Open Access Journals (Sweden)

    K. A. Trukhanov

    2014-01-01

    Full Text Available State-of-the-art machinery development enables people with lost lower limb to continue their previous life despite a loss. International companies dealing with this area pursue a minimization of human behaviour problems because of amputation. Researches to create an optimal design of the artificial knee joint are under way.The work task was to define analytical relationships of changing kinematic parameters of the human walking on the flat surface such as an angle of the knee joint, knee point (moment, definition of reduced knee actuator (A load, as well as to compare obtained results with experimental data.As an A in created design, the article proposes to use a controlled shock absorber based on the hydraulic cylinder.A knee unit is a kinematic two-tier mechanism. One of the mechanism links performs rotational motion, and the other is rotation-translational to provide a rotation of the first one.When studying the hydraulic actuator device dynamics, as a generalized coordinate a coordinate of the piston x (or ρ position is chosen while in the study of link movements an angle β is preferable.Experimental data are obtained for a human with the body weight of 57.6 kg walking on the flat surface to estimate a value of the knee joint angle, speed, acceleration, torque, and capacity in the knee joint and are taken from the published works of foreign authors.A trigonometric approximation was used for fitting the experimental data. The resulting dependence of the reduced load on the stock of A is necessary to perform the synthesis of A. The criterion for linear mechanisms mentioned in the D.N. Popov’s work is advisable to use as a possible criterion for optimization of A.The results obtained are as follows:1. Kinematics linkage mechanism is described using relationships for dependencies of its geometrical parameters, namely a cylinder piston stroke x (or ρ and a links angle β.2. Obtained polynomials of kinematic relationships allow a synthesis of

  11. Randomized trial investigating the efficacy of manual lymphatic drainage to improve early outcome after total knee arthroplasty.

    Science.gov (United States)

    Ebert, Jay R; Joss, Brendan; Jardine, Berit; Wood, David J

    2013-11-01

    To investigate the efficacy of manual lymphatic drainage (MLD) in the early postoperative period after total knee arthroplasty (TKA) to reduce edema and pain and improve knee range of motion. Prospective randomized controlled trial. Private hospital and functional rehabilitation clinic. Consecutive sample of patients (N=43; 53 knees) scheduled for TKA. MLD (vs no MLD) on days 2, 3, and 4 postoperatively. Both groups underwent conventional, concomitant physical therapy. Clinical assessment was undertaken pre- and postoperatively prior to and after the designated postoperative MLD sessions (days 2, 3, and 4) and at 6 weeks postsurgery. This included active knee flexion and extension range of motion, lower limb girths (ankle, midpatella, thigh, and calf), and knee pain using a numeric rating scale and the Knee Injury and Osteoarthritis Outcome Score. A significant group effect was observed for active knee flexion, with post hoc tests demonstrating a significantly greater active knee flexion in the MLD group when compared with the control (no MLD) group at the final measure prior to hospital discharge (day 4 postsurgery) and at 6 weeks postsurgery. There were no further group effects observed for the remaining patient-reported and functional outcomes. MLD in the early postoperative stages after TKA appears to improve active knee flexion up to 6 weeks postsurgery, in addition to conventional care. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. The Effect of Work Boots on Knee Mechanics and the Center of Pressure at the Knee During Static Kneeling.

    Science.gov (United States)

    Tennant, Liana; Kingston, David; Chong, Helen; Acker, Stacey

    2015-10-01

    Occupational kneeling is associated with an increased risk for the development of knee osteoarthritis. Previous work studying occupational kneeling has neglected to account for the fact that in many industrial settings, workers are required to wear steel-toe work boots. Thus, the purpose of this study was to evaluate the effect of work boot wear on the center of pressure location of the ground reaction force, knee joint angle, and magnitude of the ground reaction force in a kneeling posture. Fifteen healthy males were fit with 3D motion capture markers and knelt statically over a force plate embedded in the floor. Using the tibial tuberosity as the point of reference, the center of pressure in shod condition was shifted significantly medially (on average 0.009 m [P = .005]) compared with the barefoot condition. The knee was significantly less internally rotated (shod: -12.5° vs. barefoot: -17.4° [P = .009]) and the anterior/posterior shear force was significantly greater in the shod condition (shod: 6.0% body weight vs. barefoot: 1.5% body weight [P = .002]). Therefore, wearing work boots alters the kneeling posture compared with barefoot kneeling, potentially loading different surfaces of the knee, as well as altering knee joint moments.

  13. Effects of tibial slope changes in the stability of fixed bearing medial unicompartmental arthroplasty in anterior cruciate ligament deficient knees.

    Science.gov (United States)

    Suero, Eduardo M; Citak, Musa; Cross, Michael B; Bosscher, Marianne R F; Ranawat, Anil S; Pearle, Andrew D

    2012-08-01

    Patients with anterior cruciate ligament (ACL) deficiency may have increased failure rates with UKA as a result of abnormal contact stresses and altered knee kinematics. Variations in the slope of the tibial component in UKA may alter tibiofemoral translation, and affect outcomes. This cadaveric study evaluated tibiofemoral translation during the Lachman and pivot shift tests after changing the slope of a fixed bearing unicondylar tibial component. Sectioning the ACL increased tibiofemoral translation in both the Lachman and pivot shift tests (Pslope leveling (decreasing the posterior slope) of the polyethylene insert in a UKA decreases anteroposterior tibiofemoral translation in the sagittal plane to a magnitude similar to that of the intact knee. With 8° of tibial slope leveling, anterior tibial translation during the Lachman test decreased by approximately 5mm. However, no variation in slope altered the pivot shift kinematics in the ACL deficient knees. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. How Anterior Cruciate Ligament Injury was averted during Knee Collapse in a NBA Point Guard.

    Science.gov (United States)

    Schilaty, Nathan D; Bates, Nathaniel A; Krych, Aaron J; Hewett, Timothy E

    2017-01-01

    Non-contact anterior cruciate ligament (ACL) injuries occur with rapid decelerations and pivoting. A recent injury to a high-level National Basketball Association (NBA) player demonstrated neuromuscular control and injury-sparing mechanisms that resulted in only minor ligament injury to the medial collateral ligament. We analyzed biomechanical mechanisms via publically available orthogonal 2-D video to demonstrate how this potential ACL injury was averted. Analysis of the knee injury mechanism demonstrated that the NBA player experienced low ground reaction force, high sagittal plane flexion, and maintenance of frontal plane stability with neuromuscular control. The outcome of these factors inhibited dynamic valgus collapse of the knee throughout the fall, avoiding ACL injury - a potentially career-altering injury. Many athletes, professional and recreational, will be subjected to similar mechanisms of injury and will have improved outcomes if they can successfully utilize preventive strategies of neuromuscular control to limit injury mechanisms.

  15. Knee strength retention and analgesia with continuous perineural fentanyl infusion after total knee replacement: randomized controlled trial.

    Science.gov (United States)

    Mangar, Devanand; Karlnoski, Rachel A; Sprenker, Collin J; Downes, Katheryne L; Taffe, Narrene; Wainwright, Robert; Gustke, Kenneth; Bernasek, Thomas L; Camporesi, Enrico

    2014-04-01

    Despite providing adequate pain relief, a femoral nerve block can induce postoperative muscle weakness after total knee arthoplasty (TKA). Fentanyl has been shown to have peripheral effects but has not been used as a perineural infusate alone after TKA. Sixty patients scheduled for TKA were randomized to one of three blinded groups: a continuous 24 h infusion of either fentanyl 3 μg/ml, ropivacaine 0.1%, or 0.9% normal saline through a femoral nerve sheath catheter at 10 ml/h. The main outcome was maximum voluntary isometric contraction (MVIC) in the quadriceps femoris (knee extension), measured by a handheld dynamometer (Nm/kg). Other variables assessed were preoperative and postoperative visual analog scale (VAS) scores, hamstrings MVIC (knee flexion), active range of motion of the operative knee, distance ambulated, incidence of knee buckling, supplemental morphine usage, postoperative side effects, and serum fentanyl levels. Quadriceps MVIC values were significantly greater in the fentanyl group compared to the group that received ropivacaine (median values, 0.08 vs. 0.03 Nm/kg; p = 0.028). The incidence of postoperative knee buckling upon ambulation was higher in the ropivacaine group compared to the fentanyl group, although not statistically significant (40% vs. 15 %, respectively; p = 0.077). VAS scores while ambulating were not significantly different between the fentanyl group and the ropivacaine group (p = 0.270). Postoperative morphine consumption, nausea and vomiting, and resting VAS scores were similar among the three groups. A continuous perineural infusion of fentanyl produced greater strength retention than ropivacaine post-TKA.

  16. Formal Physical Therapy May Not Be Necessary After Unicompartmental Knee Arthroplasty: A Randomized Clinical Trial.

    Science.gov (United States)

    Fillingham, Yale A; Darrith, Brian; Lonner, Jess H; Culvern, Chris; Crizer, Meredith; Della Valle, Craig J

    2018-02-21

    The purpose of this randomized clinical trial was to compare formal outpatient physical therapy (PT) and unsupervised home exercises after unicompartmental knee arthroplasty (UKA). Fifty-two patients were randomized to 6 weeks of outpatient PT or an unsupervised home exercise program after UKA. The primary outcome was change in range of motion at 6 weeks with secondary outcomes including total arc of motion, Knee Society Score, Knee Injury and Osteoarthritis Outcome Score Jr, Lower Extremity Functional Scale, and Veterans Rands-12 score. Twenty-five patients received outpatient PT, 22 patients the self-directed exercise program, while 3 patients deviated from the protocol, 1 patient withdrew, and 1 patient was lost to follow-up. There was no difference in the change of range of motion (P = .43) or total arc of motion at 6 weeks (P = .17) between the groups and likewise no significant differences were found in any of the secondary outcomes. Two patients who crossed over from the unsupervised home exercise program to formal outpatient PT within the first 2 weeks postoperatively required a manipulation under anesthesia. Our results suggest self-directed exercises may be appropriate for most patients following UKA. However, there is a subset of patients who may benefit from formal PT. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Comparison of lower limb kinetics during vertical jumps in turnout and neutral foot positions by classical ballet dancers.

    Science.gov (United States)

    Imura, Akiko; Iino, Yoichi

    2017-03-01

    The purpose of this study was to investigate the effect of hip external rotation (turnout) on lower limb kinetics during vertical jumps by classical ballet dancers. Vertical jumps in a turnout (TJ) and a neutral hip position (NJ) performed by 12 classical female ballet dancers were analysed through motion capture, recording of the ground reaction forces, and inverse dynamics analysis. At push-off, the lower trunk leaned forward 18.2° and 20.1° in the TJ and NJ, respectively. The dancers jumped lower in the TJ than in the NJ. The knee extensor and hip abductor torques were smaller, whereas the hip external rotator torque was larger in the TJ than in the NJ. The work done by the hip joint moments in the sagittal plane was 0.28 J/(Body mass*Height) and 0.33 J/(Body mass*Height) in the TJ and NJ, respectively. The joint work done by the lower limbs were not different between the two jumps. These differences resulted from different planes in which the lower limb flexion-extension occurred, i.e. in the sagittal or frontal plane. This would prevent the forward lean of the trunk by decreasing the hip joint work in the sagittal plane and reduce the knee extensor torque in the jump.

  18. Influence of spinal sagittal alignment, body balance, muscle strength, and physical ability on falling of middle-aged and elderly males.

    Science.gov (United States)

    Imagama, Shiro; Ito, Zenya; Wakao, Norimitsu; Seki, Taisuke; Hirano, Kenichi; Muramoto, Akio; Sakai, Yoshihito; Matsuyama, Yukihiro; Hamajima, Nobuyuki; Ishiguro, Naoki; Hasegawa, Yukiharu

    2013-06-01

    Risk factors for falling in elderly people remain uncertain, and the effects of spinal factors and physical ability on body balance and falling have not been examined. The objective of this study was to investigate how factors such as spinal sagittal alignment, spinal range of motion, body balance, muscle strength, and gait speed influence falling in the prospective cohort study. The subjects were 100 males who underwent a basic health checkup. Balance, SpinalMouse(®) data, grip strength, back muscle strength, 10-m gait time, lumbar lateral standing radiographs, body mass index, and fall history over the previous year were examined. Platform measurements of balance included the distance of movement of the center of pressure (COP) per second (LNG/TIME), the envelopment area traced by movement of the COP (E AREA), and the LNG/E AREA ratio. The thoracic/lumbar angle ratio (T/L ratio) and sagittal vertical axis (SVA) were used as an index of sagittal balance. LNG/TIME and E AREA showed significant positive correlations with age, T/L ratio, SVA, and 10-m gait time; and significant negative correlations with lumbar lordosis angle, sacral inclination angle, grip strength and back muscle strength. Multiple regression analysis showed significant differences for LNG/TIME and E AREA with T/L ratio, SVA, lumbar lordosis angle and sacral inclination angle (R (2) = 0.399). Twelve subjects (12 %) had experienced a fall over the past year. Age, T/L ratio, SVA, lumbar lordosis angle, sacral inclination angle, grip strength, back muscle strength, 10-m gait time, height of the intervertebral disc, osteophyte formation in radiographs and LNG/E AREA differed significantly between fallers and non-fallers. The group with SVA > 40 mm (n = 18) had a significant higher number of subjects with a single fall (6 single fallers/18: p = 0.0075) and with multiple falls (4 multiple fallers/18: p = 0.0095). Good spinal sagittal alignment, muscle strength and 10-m gait speed improve body balance

  19. Quasi-stiffness of the knee joint in flexion and extension during the golf swing.

    Science.gov (United States)

    Choi, Ahnryul; Sim, Taeyong; Mun, Joung Hwan

    2015-01-01

    Biomechanical understanding of the knee joint during a golf swing is essential to improve performance and prevent injury. In this study, we quantified the flexion/extension angle and moment as the primary knee movement, and evaluated quasi-stiffness represented by moment-angle coupling in the knee joint. Eighteen skilled and 23 unskilled golfers participated in this study. Six infrared cameras and two force platforms were used to record a swing motion. The anatomical angle and moment were calculated from kinematic and kinetic models, and quasi-stiffness of the knee joint was determined as an instantaneous slope of moment-angle curves. The lead knee of the skilled group had decreased resistance duration compared with the unskilled group (P golf swing and developing rehabilitation strategies following surgery.

  20. Effects of non-surgical joint distraction in the treatment of severe knee osteoarthritis.

    Science.gov (United States)

    Khademi-Kalantari, Khosro; Mahmoodi Aghdam, Somayeh; Akbarzadeh Baghban, Alireza; Rezayi, Mehdi; Rahimi, Abbas; Naimee, Sedighesadat

    2014-10-01

    The aim of this study was to evaluate the clinical results of non surgical knee distraction in patients with severe knee osteoarthritis. forty female patients with severe knee osteoarthritis were randomly divided in two groups. A standard physiotherapy treatment was applied to both groups and in one group it was accompanied with 20 min knee joint distraction. The patients were treated for 10 sessions. Clinical examination consisted of functional examination, completion of a quality of life questionnaire, pain scale, and assessment of joint mobility and joint edema. The standard physiotherapy treatment accompanied by knee distraction resulted in significantly higher improvement in pain (P = 0.004), functional ability (P = 0.02), quality of life (P = 0.002) and knee flexion range of motion (p = 0.02) compared to the standard physiotherapy treatment alone post treatment and after 1 month follow up. Adding knee distraction to standard physiotherapy treatment can result in further improvement in pain relief, increased functional ability and better quality of life in patients with severe knee osteoarthritis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Kinematic analysis of hip and knee rotation and other contributors to ballet turnout.

    Science.gov (United States)

    Quanbeck, Amy E; Russell, Jeffrey A; Handley, Sara C; Quanbeck, Deborah S

    2017-02-01

    Turnout, or external rotation (ER) of the lower extremities, is essential in ballet. The purpose of this study was to utilise physical examination and a biomechanical method for obtaining functional kinematic data using hip and knee joint centres to identify the relative turnout contributions from hip rotation, femoral anteversion, knee rotation, tibial torsion, and other sources. Ten female dancers received a lower extremity alignment assessment, including passive hip rotation, femoral anteversion, tibial torsion, weightbearing foot alignment, and Beighton hypermobility score. Next, turnout was assessed using plantar pressure plots and three-dimensional motion analysis; participants performed turnout to ballet first position on both a plantar pressure mat and friction-reducing discs. A retro-reflective functional marker motion capture system mapped the lower extremities and hip and knee joint centres. Mean total turnout was 129±15.7° via plantar pressure plots and 135±17.8° via kinematics. Bilateral hip ER during turnout was 49±10.2° (36% of total turnout). Bilateral knee ER during turnout was 41±5.9° (32% of total turnout). Hip ER contribution to total turnout measured kinematically was less than expected compared to other studies, where hip ER was determined without functional kinematic data. Knee ER contributed substantially more turnout than expected or previously reported. This analysis method allows precise assessment of turnout contributors.

  2. Lower extremity joint coupling variability during gait in young adults with and without chronic ankle instability.

    Science.gov (United States)

    Lilley, Thomas; Herb, Christopher C; Hart, Joseph; Hertel, Jay

    2018-06-01

    Chronic ankle instability (CAI) is a condition resulting from a lateral ankle sprain. Shank-rearfoot joint-coupling variability differences have been found in CAI patients; however, joint-coupling variability (VCV) of the ankle and proximal joints has not been explored. Our purpose was to analyse VCV in adults with and without CAI during gait. Four joint-coupling pairs were analysed: knee sagittal-ankle sagittal, knee sagittal-ankle frontal, hip frontal-ankle sagittal and hip frontal-ankle frontal. Twenty-seven adults participated (CAI:n = 13, Control:n = 14). Lower extremity kinematics were collected during walking (4.83 km/h) and jogging (9.66 km/h). Vector-coding was used to assess the stride-to-stride variability of four coupling pairs. During walking, CAI patients exhibited higher VCV than healthy controls for knee sagittal-ankle frontal in latter parts of stance thru mid-swing. When jogging, CAI patients demonstrated lower VCV with specific differences occurring across various intervals of gait. The increased knee sagittal-ankle frontal VCV in CAI patients during walking may indicate an adaptation to deal with the previously identified decrease in variability in transverse plane shank and frontal plane rearfoot coupling during walking; while the decreased ankle-knee and ankle-hip VCV identified in CAI patients during jogging may represent a more rigid, less adaptable sensorimotor system ambulating at a faster speed.

  3. Peri-implant bone strains and micro-motion following in vivo service: a postmortem retrieval study of 22 tibial components from total knee replacements.

    Science.gov (United States)

    Mann, Kenneth A; Miller, Mark A; Goodheart, Jacklyn R; Izant, Timothy H; Cleary, Richard J

    2014-03-01

    Biological adaptation following placement of a total knee replacements (TKRs) affects peri-implant bone mineral density (BMD) and implant fixation. We quantified the proximal tibial bone strain and implant-bone micro-motion for functioning postmortem retrieved TKRs and assessed the strain/micro-motion relationships with chronological (donor age and time in service) and patient (body weight and BMD) factors. Twenty-two tibial constructs were functionally loaded to one body weight (60% medial/40% lateral), and the bone strains and tray/bone micro-motions were measured using a digital image correlation system. Donors with more time in service had higher bone strains (p = 0.044), but there was not a significant (p = 0.333) contribution from donor age. Donors with lower peri-implant BMD (p = 0.0039) and higher body weight (p = 0.0286) had higher bone strains. Long term implants (>11 years) had proximal bone strains 900 µϵ that were almost twice as high as short term (implants 570 µϵ. Micro-motion was greater for younger donors (p = 0.0161) and longer time in service (p = 0.0008). Increased bone strain with long term in vivo service could contribute to loosening of TKRs by failure of the tibial peri-implant bone. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Cartilage volume quantification with multi echo data image combination sequence in swine knee at 3.0 T MRI

    International Nuclear Information System (INIS)

    Zhang Lirong; Wang Dongqing; Wei Chuanshe; Ma Cong; Wang Dehang

    2010-01-01

    Objective: To investigate the accuracy and reproducibility of multi echo data imagine combination (MEDIC) sequence with water excitation at 3.0 T in swine knee cartilage. Methods: Sagittal MEDIC sequences (0.6 mm slice thickness, isotropic) were acquired twice at 3.0 T MRI in 30 swine knees. The knee cartilage was then removed and the volume was directly measured with water substitution method. The cartilage volume was also determined with a validated open source image software OsiriX by two observers (A and B). The cartilage volumes obtained by two methods were compared. The reproducibility of MEDIC for quantitative measurement was accessed by the root-mean-square (RMS) of variation coefficient. Interobserver and intraobserver precision errors were compared using a paired students t-test. The accuracy of MEDIC for quantitative measurement was determined by the random pairwise differences, systematic pairwise differences and the Pearson, correlation coefficients. Time of semiautomatic and manual segmentation were recorded. Results: Time was saved about 75% by using semiautomatic segmentation methods [(4.0± 1.5) min] versus manual segmentation [(16.0±0.9) min]. Interobserver precision errors (RMS CV% for paired analysis) between A and B for cartilage volume measurement were (2.66±0.82) ml and(2.61± 0.81) ml, t=0.24, P=0.81 (patella); (2.40±0.69) ml and (2.49±0.85) ml, t=-0.45, P=0.65 (medial femoral condyle); (2.28±0.74) ml and(2.41±0.78) ml, t=-0.66, P=0.51 (lateral femoral condyle); (3.43±1.28) ml and (3.51±1.08) ml, t=-0.26, P=0.79 (femora trochlea) with sagittal MEDIC. Intraobserver precision errors (RMS CV% for paired analysis) of observer A for the first and second cartilage volume measurement were (2.64±0.62) ml and (2.67±0.60) ml, t=-0.19, P=0.85 (patella); (2.43±0.60) ml and (2.39±0.59) ml, t=0.26, P=0.80 (medial femoral condyle); (2.26±0.56) ml and (2.30±0.57) ml, t=-0.27, P=0.78 (lateral femoral condyle); (3.40± 1.20) ml and (3.47±1

  5. Real-time knee adduction moment feedback training using an elliptical trainer.

    Science.gov (United States)

    Kang, Sang Hoon; Lee, Song Joo; Ren, Yupeng; Zhang, Li-Qun

    2014-03-01

    The external knee adduction moment (EKAM) is associated with knee osteoarthritis (OA) in many aspects including presence, progression, and severity of knee OA. Despite of its importance, there is a lack of EKAM estimation methods that can provide patients with knee OA real-time EKAM biofeedback for training and clinical evaluations without using a motion analysis laboratory. A practical real-time EKAM estimation method, which utilizes kinematics measured by a simple six degree-of-freedom goniometer and kinetics measured by a multi-axis force sensor underneath the foot, was developed to provide real-time feedback of the EKAM to the patients during stepping on an elliptical trainer, which can potentially be used to control and alter the EKAM. High reliability (ICC(2,1): 0.9580) of the real-time EKAM estimation method was verified through stepping trials of seven subjects without musculoskeletal disorders. Combined with advantages of elliptical trainers including functional weight-bearing stepping and mitigation of impulsive forces, the real-time EKAM estimation method is expected to help patients with knee OA better control frontal plane knee loading and reduce knee OA development and progression.

  6. Comparison of clinical outcomes between total knee arthroplasty and unicompartmental knee arthroplasty for osteoarthritis of the knee: a retrospective analysis of preoperative and postoperative results.

    Science.gov (United States)

    Horikawa, Akira; Miyakoshi, Naohisa; Shimada, Yoichi; Kodama, Hiroyuki

    2015-10-28

    Excellent results have recently been reported for both total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA), but there have been few reports about which has a better long-term outcome. The preoperative and postoperative results of TKA and UKA for osteoarthritis of the knee were thus compared. The results of 48 patients who underwent TKA and 25 patients who underwent UKA were evaluated based on clinical scores and survivorship in the middle long-term period. Preoperative, latest postoperative, and changes in the femoro-tibial angle (FTA), range of motion (ROM), Japanese Orthopedic Association score (JOA score), and Japanese Knee Osteoarthritis Measure (JKOM) were compared. The patients' mean age was 73 years. The mean follow-up period was 9 years (TKA: mean, 10.5 years; range, 7-12 years; UKA: mean, 9 years; range, 6-11 years). Preoperative FTA and ROM were significantly higher in the UKA group than in the TKA group. Total changes in all scores were similar among the two groups, as were changes in scores for all JOA and JKOM domains. The cumulative revision rate was higher for UKA than for TKA (7 versus 4%). Kaplan-Meier survivorship at 10 years was 84% for UKA and 92% for TKA. This clinical study found no significant differences between TKA and UKA, except in long-term survivorship.

  7. Designs and performance of three new microprocessor-controlled knee joints.

    Science.gov (United States)

    Thiele, Julius; Schöllig, Christina; Bellmann, Malte; Kraft, Marc

    2018-02-09

    A crossover design study with a small group of subjects was used to evaluate the performance of three microprocessor-controlled exoprosthetic knee joints (MPKs): C-Leg 4, Plié 3 and Rheo Knee 3. Given that the mechanical designs and control algorithms of the joints determine the user outcome, the influence of these inherent differences on the functional characteristics was investigated in this study. The knee joints were evaluated during level-ground walking at different velocities in a motion analysis laboratory. Additionally, technical analyses using patents, technical documentations and X-ray computed tomography (CT) for each knee joint were performed. The technical analyses showed that only C-Leg 4 and Rheo Knee 3 allow microprocessor-controlled adaptation of the joint resistances for different gait velocities. Furthermore, Plié 3 is not able to provide stance extension damping. The biomechanical results showed that only if a knee joint adapts flexion and extension resistances by the microprocessor all known advantages of MPKs can become apparent. But not all users may benefit from the examined functions: e.g. a good accommodation to fast walking speeds or comfortable stance phase flexion. Hence, a detailed comparison of user demands and performance of the designated knee joint is mandatory to ensure a maximum in user outcome.

  8. Biomechanical risk factors and mechanisms of knee injury in golfers.

    Science.gov (United States)

    Marshall, Robert N; McNair, Peter J

    2013-09-01

    Knee injuries in golf comprise approximately 8% of all injuries, and are considered to result from overuse, technical faults or a combination of those factors. This review examines factors involved in injury, including the structure of the knee joint, kinematics and kinetics of the golf swing, forces sustained by knee joint structures and the potential for joint injury as well as injury prevention strategies. The golf swing generates forces and torques which tend to cause internal or external rotation of the tibia on the femur, and these are resisted by the knee ligaments and menisci. Research has shown that both maximum muscle forces and the forces sustained during a golf swing are less than that required to cause damage to the ligaments. However, the complex motion of the golf swing, involving both substantial forces and ranges of rotational movement, demands good technique if the player is to avoid injuring their knee joint. Most knee injury in golf is likely related to joint laxity, previous injuries or arthritis, and such damage may be exacerbated by problems in technique or overuse. In addition to appropriate coaching, strategies to remedy discomfort include specific exercise programmes, external bracing, orthotics and equipment choices.

  9. Influence of implant rod curvature on sagittal correction of scoliosis deformity.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2014-08-01

    Deformation of in vivo-implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. To analyze the changes of the implant rod's angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. Twenty adolescent idiopathic scoliosis patients underwent surgery. Average age at the time of operation was 14 years. The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. Two implant rods were attached to the concave and convex side of the spinal deformity. The preoperative implant rod geometry was measured before surgical implantation. The postoperative implant rod geometry after surgery was measured by computed tomography. The implant rod angle of curvature at the sagittal plane was obtained from the implant rod geometry. The angle of curvature between the implant rod extreme ends was measured before implantation and after surgery. The sagittal curvature between the corresponding spinal levels of healthy adolescents obtained by previous studies was compared with the implant rod angle of curvature to evaluate the sagittal curve correction. The difference between the postoperative implant rod angle of curvature and normal spine sagittal curvature of the corresponding instrumented level was used to evaluate over or under correction of the sagittal deformity. The implant rods at the concave side of deformity of all patients were significantly deformed after surgery. The average degree of rod deformation Δθ at the concave and convex sides was 15.8° and 1.6°, respectively. The average preoperative and postoperative implant rod angle of curvature at the concave side was 33.6° and 17.8

  10. Intravoxel incoherent motion magnetic resonance imaging of the knee joint in children with juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, Fabian; Sauer, Alexander; Koestler, Herbert [University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Holl-Wieden, Annette [University Hospital Wuerzburg, Department of Paediatrics, Wuerzburg (Germany); Neubauer, Henning [University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2017-05-15

    MRI of synovitis relies on use of a gadolinium-based contrast agent. Diffusion-weighted MRI (DWI) visualises thickened synovium but is of limited use in the presence of joint effusion. To investigate the feasibility and diagnostic accuracy of diffusion-weighted MRI with intravoxel incoherent motion (IVIM) for diagnosing synovitis in the knee joint of children with juvenile idiopathic arthritis. Twelve consecutive children with confirmed or suspected juvenile idiopathic arthritis (10 girls, median age 11 years) underwent MRI with contrast-enhanced T1-weighted imaging and DWI at 1.5 T. Read-out segmented multi-shot DWI was acquired at b values of 0 s/mm{sup 2}, 200 s/mm{sup 2}, 400 s/mm{sup 2} and 800 s/mm{sup 2}. We calculated the IVIM parameters perfusion fraction (f) and tissue diffusion coefficient (D). Diffusion-weighted images at b=800 s/mm{sup 2}, f parameter maps and post-contrast T1-weighted images were retrospectively assessed by two independent readers for synovitis using the Juvenile Arthritis MRI Scoring system. Seven (58%) children showed synovial hypertrophy on contrast-enhanced imaging. Diagnostic ratings for synovitis on DWI and on f maps were fully consistent with contrast-enhanced imaging, the diagnostic reference. Two children had equivocal low-confidence assessments on DWI. Median f was 6.7±2.0% for synovitis, 2.1±1.2% for effusion, 5.0±1.0% for muscle and 10.6±5.7% for popliteal lymph nodes. Diagnostic confidence was higher based on f maps in three (25%) children and lower in one child (8%), as compared to DWI. DWI with IVIM reliably visualises synovitis of the knee joint. Perfusion fraction maps differentiate thickened synovium from joint effusion and hence increase diagnostic confidence. (orig.)

  11. Lumbar motion changes in chronic low back pain patients

    DEFF Research Database (Denmark)

    Mieritz, Rune M; Hartvigsen, Jan; Boyle, Eleanor

    2014-01-01

    BACKGROUND CONTEXT: Several therapies have been used in the treatment of chronic low back pain, including various exercise strategies and spinal manipulative therapy. A common belief is that spinal motion changes in particular ways in direct response to specific interventions, such as exercise...... or spinal manipulation. PURPOSE: The purpose of this study was to assess changes in lumbar region motion over 12 weeks by evaluating four motion parameters in the sagittal plane and two in the horizontal plane in LBP patients treated with either exercise therapy or spinal manipulation. STUDY DESIGN......, and the University of Southern Denmark. No conflicts of interest. RESULTS: For the cohort as a whole, lumbar region motion parameters were altered over the 12-week period, except for the jerk index parameter. The group receiving spinal manipulation changed significantly in all, and the exercise groups in half...

  12. Effect of children's shoes on gait: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Burns Joshua

    2011-01-01

    Full Text Available Abstract Background The effect of footwear on the gait of children is poorly understood. This systematic review synthesises the evidence of the biomechanical effects of shoes on children during walking and running. Methods Study inclusion criteria were: barefoot and shod conditions; healthy children aged ≤ 16 years; sample size of n > 1. Novelty footwear was excluded. Studies were located by online database-searching, hand-searching and contact with experts. Two authors selected studies and assessed study methodology using the Quality Index. Meta-analysis of continuous variables for homogeneous studies was undertaken using the inverse variance approach. Significance level was set at P 2. Where I2 > 25%, a random-effects model analysis was used and where I2 Results Eleven studies were included. Sample size ranged from 4-898. Median Quality Index was 20/32 (range 11-27. Five studies randomised shoe order, six studies standardised footwear. Shod walking increased: velocity, step length, step time, base of support, double-support time, stance time, time to toe-off, sagittal tibia-rearfoot range of motion (ROM, sagittal tibia-foot ROM, ankle max-plantarflexion, Ankle ROM, foot lift to max-plantarflexion, 'subtalar' rotation ROM, knee sagittal ROM and tibialis anterior activity. Shod walking decreased: cadence, single-support time, ankle max-dorsiflexion, ankle at foot-lift, hallux ROM, arch length change, foot torsion, forefoot supination, forefoot width and midfoot ROM in all planes. Shod running decreased: long axis maximum tibial-acceleration, shock-wave transmission as a ratio of maximum tibial-acceleration, ankle plantarflexion at foot strike, knee angular velocity and tibial swing velocity. No variables increased during shod running. Conclusions Shoes affect the gait of children. With shoes, children walk faster by taking longer steps with greater ankle and knee motion and increased tibialis anterior activity. Shoes reduce foot motion and

  13. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  14. Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter?

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Christensen, Malene; Christensen, Stine Sommer

    2010-01-01

    : The design was an intra-tester, inter-tester and intra-day reliability study. Nineteen outpatients (10 females) having received a TKA were examined by an inexperienced and an experienced physiotherapist. Following a standardized protocol, active and passive knee joint ROM and circumference measurements were...

  15. A Novel Methodology for the Simulation of Athletic Tasks on Cadaveric Knee Joints with Respect to In Vivo Kinematics

    Science.gov (United States)

    Bates, Nathaniel A.; Nesbitt, Rebecca J.; Shearn, Jason T.; Myer, Gregory D.; Hewett, Timothy E.

    2015-01-01

    Six degree of freedom (6-DOF) robotic manipulators have simulated clinical tests and gait on cadaveric knees to examine knee biomechanics. However, these activities do not necessarily emulate the kinematics and kinetics that lead to anterior cruciate ligament (ACL) rupture. The purpose of this study was to determine the techniques needed to derive reproducible, in vitro simulations from in vivo skin-marker kinematics recorded during simulated athletic tasks. Input of raw, in vivo, skin-marker-derived motion capture kinematics consistently resulted in specimen failure. The protocol described in this study developed an in-depth methodology to adapt in vivo kinematic recordings into 6-DOF knee motion simulations for drop vertical jumps and sidestep cutting. Our simulation method repeatably produced kinetics consistent with vertical ground reaction patterns while preserving specimen integrity. Athletic task simulation represents an advancement that allows investigators to examine ACL-intact and graft biomechanics during motions that generate greater kinetics, and the athletic tasks are more representative of documented cases of ligament rupture. Establishment of baseline functional mechanics within the knee joint during athletic tasks will serve to advance the prevention, repair and rehabilitation of ACL injuries. PMID:25869454

  16. Tracking control of time-varying knee exoskeleton disturbed by interaction torque.

    Science.gov (United States)

    Li, Zhan; Ma, Wenhao; Yin, Ziguang; Guo, Hongliang

    2017-11-01

    Knee exoskeletons have been increasingly applied as assistive devices to help lower-extremity impaired people to make their knee joints move through providing external movement compensation. Tracking control of knee exoskeletons guided by human intentions often encounters time-varying (time-dependent) issues and the disturbance interaction torque, which may dramatically put an influence up on their dynamic behaviors. Inertial and viscous parameters of knee exoskeletons can be estimated to be time-varying due to unexpected mechanical vibrations and contact interactions. Moreover, the interaction torque produced from knee joint of wearers has an evident disturbance effect on regular motions of knee exoskeleton. All of these points can increase difficultly of accurate control of knee exoskeletons to follow desired joint angle trajectories. This paper proposes a novel control strategy for controlling knee exoskeleton with time-varying inertial and viscous coefficients disturbed by interaction torque. Such designed controller is able to make the tracking error of joint angle of knee exoskeletons exponentially converge to zero. Meanwhile, the proposed approach is robust to guarantee the tracking error bounded when the interaction torque exists. Illustrative simulation and experiment results are presented to show efficiency of the proposed controller. Additionally, comparisons with gradient dynamic (GD) approach and other methods are also presented to demonstrate efficiency and superiority of the proposed control strategy for tracking joint angle of knee exoskeleton. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Superior sagittal sinus thrombosis: a rare complication of nephrotic syndrome.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1999-10-01

    Full Text Available A two and half year-old-male child, known case of steroid responsive nephrotic syndrome presented with fever and vomiting of acute onset. He was diagnosed to have superior sagittal sinus thrombosis on a contrast computerised tomographic scan of brain. Recovery was complete without anticoagulant therapy. Superior sagittal sinus thrombosis is an extremely rare complication of nephrotic syndrome.

  18. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  19. Loss of knee-extension strength is related to knee swelling after total knee arthroplasty

    DEFF Research Database (Denmark)

    Holm, Bente; Kristensen, Morten T; Bencke, Jesper

    2010-01-01

    To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA).......To examine whether changes in knee-extension strength and functional performance are related to knee swelling after total knee arthroplasty (TKA)....

  20. Importance of tibial slope for stability of the posterior cruciate ligament deficient knee.

    Science.gov (United States)

    Giffin, J Robert; Stabile, Kathryne J; Zantop, Thore; Vogrin, Tracy M; Woo, Savio L-Y; Harner, Christopher D

    2007-09-01

    Previous studies have shown that increasing tibial slope can shift the resting position of the tibia anteriorly. As a result, sagittal osteotomies that alter slope have recently been proposed for treatment of posterior cruciate ligament (PCL) injuries. Increasing tibial slope with an osteotomy shifts the resting position anteriorly in a PCL-deficient knee, thereby partially reducing the posterior tibial "sag" associated with PCL injury. This shift in resting position from the increased slope causes a decrease in posterior tibial translation compared with the PCL-deficient knee in response to posterior tibial and axial compressive loads. Controlled laboratory study. Three knee conditions were tested with a robotic universal force-moment sensor testing system: intact, PCL-deficient, and PCL-deficient with increased tibial slope. Tibial slope was increased via a 5-mm anterior opening wedge osteotomy. Three external loading conditions were applied to each knee condition at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of knee flexion: (1) 134-N anterior-posterior (A-P) tibial load, (2) 200-N axial compressive load, and (3) combined 134-N A-P and 200-N axial loads. For each loading condition, kinematics of the intact knee were recorded for the remaining 5 degrees of freedom (ie, A-P, medial-lateral, and proximal-distal translations, internal-external and varus-valgus rotations). Posterior cruciate ligament deficiency resulted in a posterior shift of the tibial resting position to 8.4 +/- 2.6 mm at 90 degrees compared with the intact knee. After osteotomy, tibial slope increased from 9.2 degrees +/- 1.0 degrees in the intact knee to 13.8 degrees +/- 0.9 degrees. This increase in slope reduced the posterior sag of the PCL-deficient knee, shifting the resting position anteriorly to 4.0 +/- 2.0 mm at 90 degrees. Under a 200-N axial compressive load with the osteotomy, an additional increase in anterior tibial translation to 2.7 +/- 1.7 mm at 30 degrees was

  1. Effect of knee joint icing on knee extension strength and knee pain early after total knee arthroplasty: a randomized cross-over study.

    Science.gov (United States)

    Holm, Bente; Husted, Henrik; Kehlet, Henrik; Bandholm, Thomas

    2012-08-01

    To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty. A prospective, single-blinded, randomized, cross-over study. A fast-track orthopaedic arthroplasty unit at a university hospital. Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty. The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30 minutes of elbow icing (control treatment). The order of treatments was randomized. Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments by an assessor blinded for active or control treatment. The change in knee extension strength associated with knee icing was not significantly different from that of elbow icing (knee icing change (mean (1 SD)) -0.01 (0.07) Nm/kg, elbow icing change -0.02 (0.07) Nm/kg, P = 0.493). Likewise, the changes in knee pain at rest (P = 0.475), or knee pain during the knee extension strength measurements (P = 0.422) were not different between treatments. In contrast to observations in experimental knee effusion models and inflamed knee joints, knee joint icing for 30 minutes shortly after total knee arthroplasty had no acute effect on knee extension strength or knee pain.

  2. Cricket pace bowling: The trade-off between optimising knee angle ...

    African Journals Online (AJOL)

    Knee angle and ball release (BR) speed of injury-free premier league (club level) cricket .... variables as follows: r=0.00 - 0.25 (little or no. L heel. Ball marker. L shoulder ..... Sequential motions of body segments in striking and throwing skills:.

  3. Alterations in walking knee joint stiffness in individuals with knee osteoarthritis and self-reported knee instability.

    Science.gov (United States)

    Gustafson, Jonathan A; Gorman, Shannon; Fitzgerald, G Kelley; Farrokhi, Shawn

    2016-01-01

    Increased walking knee joint stiffness has been reported in patients with knee osteoarthritis (OA) as a compensatory strategy to improve knee joint stability. However, presence of episodic self-reported knee instability in a large subgroup of patients with knee OA may be a sign of inadequate walking knee joint stiffness. The objective of this work was to evaluate the differences in walking knee joint stiffness in patients with knee OA with and without self-reported instability and examine the relationship between walking knee joint stiffness with quadriceps strength, knee joint laxity, and varus knee malalignment. Overground biomechanical data at a self-selected gait velocity was collected for 35 individuals with knee OA without self-reported instability (stable group) and 17 individuals with knee OA and episodic self-reported instability (unstable group). Knee joint stiffness was calculated during the weight-acceptance phase of gait as the change in the external knee joint moment divided by the change in the knee flexion angle. The unstable group walked with lower knee joint stiffness (p=0.01), mainly due to smaller heel-contact knee flexion angles (pknee flexion excursions (pknee stable counterparts. No significant relationships were observed between walking knee joint stiffness and quadriceps strength, knee joint laxity or varus knee malalignment. Reduced walking knee joint stiffness appears to be associated with episodic knee instability and independent of quadriceps muscle weakness, knee joint laxity or varus malalignment. Further investigations of the temporal relationship between self-reported knee joint instability and walking knee joint stiffness are warranted. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Effect of tibial slope on the stability of the anterior cruciate ligament-deficient knee.

    Science.gov (United States)

    Voos, James E; Suero, Eduardo M; Citak, Musa; Petrigliano, Frank P; Bosscher, Marianne R F; Citak, Mustafa; Wickiewicz, Thomas L; Pearle, Andrew D

    2012-08-01

    We aimed to quantify the effect of changes in tibial slope on the magnitude of anterior tibial translation (ATT) in the anterior cruciate ligament (ACL)-deficient knee during the Lachman and mechanized pivot shift tests. We hypothesized that increased posterior tibial slope would increase the amount of ATT of an ACL-deficient knee, while leveling the slope of the tibial plateau would decrease the amount of ATT. Lachman and mechanized pivot shift tests were performed on hip-to-toe cadaveric specimens, and ATT of the lateral and the medial compartments was measured using navigation (n = 11). The ACL was then sectioned. Stability testing was repeated, and ATT was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5 or -5° of tibial slope variation after which stability testing was repeated (n = 10). Sectioning the ACL resulted in a significant increase in ATT in both the Lachman and mechanized pivot shift tests (P slope of the tibial plateau had no effect on ATT during the Lachman test (n.s.). During the mechanized pivot shift tests, a 5° increase in posterior slope resulted in a significant increase in ATT compared to the native knee (P slope reduced ATT to a level similar to that of the intact knee. Tibial slope changes did not affect the magnitude of translation during a Lachman test. However, large changes in tibial slope variation affected the magnitude of the pivot shift.

  5. Reproduction of superior sagittal sinus animal model by bypass transplantation of biomaterial graft

    Directory of Open Access Journals (Sweden)

    Qing-yong LUO

    2011-03-01

    Full Text Available Objective To establish the beagles model of superior sagittal sinus bypass graft,and explore the feasibility of reconstruction of superior sagittal sinus with biomaterials using this model.Methods Eight adult male beagles(weight: 12.5-22.0kg were involved in the present study.The superior sagittal sinus was exposed and blocked via bone window,and then anastomosed side-to-end to the biomaterial graft under the dedicated microscope of neurosurgery surgery,expectant treatment such as anti-inflammatory was given for the animals.The digital subtraction venography(DSV and color Doppler flow imaging(CDFI of superior sagittal sinus were performed in 1,2,4 and 8 weeks after the operation.Eight weeks after the operation,all the animals were sacrificed and the material graft was examined histologically.Results The DSV and CDFI of superior sagittal sinus showed that the stomas of 2 beagles were with slight stenosis and high flow velocity,of 1 beagle with small leakage and low flow velocity,while of other 5 beagles were normal.The histological examination showed endothelial cells were growing on the graft and superior sagittal sinus,and crawling toward the lumen of graft 8 weeks after the operation.Conclusion The beagles model of superior sagittal sinus bypass graft was established successfully.The short-term effect of the model was satisfactory,while further work should be performed to determine the long-term effects.

  6. Kinetic and kinematic differences between first and second landings of a drop vertical jump task: Implications for injury risk assessments✩

    Science.gov (United States)

    Bates, Nathaniel A.; Ford, Kevin R.; Myer, Gregory D.; Hewett, Timothy E.

    2013-01-01

    Background Though the first landing of drop vertical jump task is commonly used to assess biomechanical performance measures that are associated with anterior cruciate ligament injury risk in athletes, the implications of the second landing in this task have largely been ignored. We examined the first and second landings of a drop vertical jump for differences in kinetic and kinematic behaviors at the hip and knee. Methods Acohort of 239 adolescent female basketball athletes (age = 13.6 (1.6) years) completed drop vertical jump tasks from an initial height of 31 cm. A three dimensional motion capture system recorded positional data while dual force platforms recorded ground reaction forces for each trial. Findings The first landing demonstrated greater hip adduction angle, knee abduction angle, and knee abduction moment than the second landing (P-values kinetics for both the frontal and sagittal planes (P-values < 0.044). Interpretation The results have important implications for the future use of the drop vertical jump as an assessment tool for anterior cruciate ligament injury risk behaviors in adolescent female athletes. The second landing may be a more rigorous task and provides a superior tool to evaluate sagittal plane risk factors than the first landing, which may be better suited to evaluate frontal plane risk factors. PMID:23562293

  7. Iron deposits in the knee joints of a thalassemic patient

    Directory of Open Access Journals (Sweden)

    Charalambos P Economides

    2013-02-01

    Full Text Available The overall prognosis for patients with ß-thalassemia has improved considerably during the past decades mainly due to regular blood transfusions, improvements in chelation therapy, and enhanced surveillance with imaging studies examining iron overload and other clinical complications. However, the prolonged survival of these patients leads to the development of other health problems including degenerative diseases such as arthropathies, which require further attention since they have a significant impact on the quality of life. In the current case report, we present a 45-year-old white man with ß-thalassemia complaining of non-traumatic pain and restriction in the range of motion of both knees. Magnetic resonance imaging (MRI revealed a tear in the medial meniscus of the left knee as well as iron deposits in both knees. Histological findings confirmed the presence of hemosiderin in both joints. To our knowledge, this is the first reported case of macroscopically documented iron deposits in the knee joints of a patient with ß-thalassemia using MRI.

  8. Movement detection impaired in patients with knee osteoarthritis compared to healthy controls

    DEFF Research Database (Denmark)

    Lund, H; Juul-Kristensen, Birgit; Hansen, Klaus

    2009-01-01

    The purpose of this study was to clarify whether osteoarthritis (OA) patients have a localized or a generalized reduction in proprioception. Twenty one women with knee OA (mean age [SD]: 57.1 [12.0] years) and 29 healthy women (mean age [SD]: 55.3 [10.1] years) had their joint position sense (JPS......) and threshold to detection of a passive movement (TDPM) measured in both knees and elbows. JPS was measured as the participant's ability to actively reproduce the position of the elbow and knee joints. TDPM was measured as the participant's ability to recognize a passive motion of the elbow and knee joints....... The absolute error (AE) for JPS (i.e., absolute difference in degrees between target and estimated position) and for TDPM (i.e., the difference in degrees at movement start and response when recognizing the movement) was calculated. For TDPM a higher AE (mean [SE]) was found in the involved knees in patients...

  9. A reliable low-cost wireless and wearable gait monitoring system based on a plastic optical fibre sensor

    International Nuclear Information System (INIS)

    Bilro, L; Pinto, J L; Oliveira, J G; Nogueira, R N

    2011-01-01

    A wearable and wireless system designed to evaluate quantitatively the human gait is presented. It allows knee sagittal motion monitoring over long distances and periods with a portable and low-cost package. It is based on the measurement of transmittance changes when a side-polished plastic optical fibre is bent. Four voluntary healthy subjects, on five different days, were tested in order to assess inter-day and inter-subject reliability. Results have shown that this technique is reliable, allows a one-time calibration and is suitable in the diagnosis and rehabilitation of knee injuries or for monitoring the performance of competitive athletes. Environmental testing was accomplished in order to study the influence of different temperatures and humidity conditions

  10. Modelling of subject specific based segmental dynamics of knee joint

    Science.gov (United States)

    Nasir, N. H. M.; Ibrahim, B. S. K. K.; Huq, M. S.; Ahmad, M. K. I.

    2017-09-01

    This study determines segmental dynamics parameters based on subject specific method. Five hemiplegic patients participated in the study, two men and three women. Their ages ranged from 50 to 60 years, weights from 60 to 70 kg and heights from 145 to 170 cm. Sample group included patients with different side of stroke. The parameters of the segmental dynamics resembling the knee joint functions measured via measurement of Winter and its model generated via the employment Kane's equation of motion. Inertial parameters in the form of the anthropometry can be identified and measured by employing Standard Human Dimension on the subjects who are in hemiplegia condition. The inertial parameters are the location of centre of mass (COM) at the length of the limb segment, inertia moment around the COM and masses of shank and foot to generate accurate motion equations. This investigation has also managed to dig out a few advantages of employing the table of anthropometry in movement biomechanics of Winter's and Kane's equation of motion. A general procedure is presented to yield accurate measurement of estimation for the inertial parameters for the joint of the knee of certain subjects with stroke history.

  11. Mechanical factors relate to pain in knee osteoarthritis.

    Science.gov (United States)

    Maly, Monica R; Costigan, Patrick A; Olney, Sandra J

    2008-07-01

    Pain experienced by people with knee osteoarthritis is related to psychosocial factors and damage to articular tissues and/or the pain pathway itself. Mechanical factors have been speculated to trigger this pain experience; yet mechanics have not been identified as a source of pain in this population. The purpose of this study was to identify whether mechanics could explain variance in pain intensity in people with knee osteoarthritis. Data from 53 participants with physician-diagnosed knee osteoarthritis (mean age=68.5 years; standard deviation=8.6 years) were analyzed. Pain intensity was reported on the Western Ontario and McMaster Universities Osteoarthritis Index. Mechanical measures included weight-bearing varus-valgus alignment, body mass index and isokinetic quadriceps torque. Gait analysis captured the range of adduction-abduction angle, range of flexion-extension angle and external knee adduction moment during level walking. Pain intensity was significantly related to the dynamic range of flexion-extension during gait and body mass index. A total of 29% of the variance in pain intensity was explained by mechanical variables. The range of flexion-extension explained 18% of variance in pain intensity. Body mass index added 11% to the model. The knee adduction moment was unrelated to pain intensity. The findings support that mechanical factors are related to knee osteoarthritis pain. Because limitations in flexion-extension range of motion and body size are modifiable factors, future research could examine whether interventions targeting these mechanics would facilitate pain management.

  12. Low Level Laser Therapy for chronic knee joint pain patients.

    Science.gov (United States)

    Nakamura, Takashi; Ebihara, Satoru; Ohkuni, Ikuko; Izukura, Hideaki; Harada, Takashi; Ushigome, Nobuyuki; Ohshiro, Toshio; Musha, Yoshiro; Takahashi, Hiroshi; Tsuchiya, Kazuaki; Kubota, Ayako

    2014-12-27

    Chronic knee joint pain is one of the most frequent complaints which is seen in the outpatient clinic in our medical institute. In previous studies we have reported the benefits of low level laser therapy (LLLT) for chronic pain in the shoulder joints, elbow, hand, finger and the lower back. The present study is a report on the effects of LLLT for chronic knee joint pain. Over the past 5 years, 35 subjects visited the outpatient clinic with complaints of chronic knee joint pain caused by the knee osteoarthritis-induced degenerative meniscal tear. They received low level laser therapy. A 1000 mW semi-conductor laser device was used to deliver 20.1 J/cm(2) per point in continuous wave at 830nm, and four points were irradiated per session (1 treatment) twice a week for 4 weeks. A visual analogue scale (VAS) was used to determine the effects of LLLT for the chronic pain and after the end of the treatment regimen a significant improvement was observed (pknee joint range of motion. Discussions with the patients revealed that it was important for them to learn how to avoid postures that would cause them knee pain in everyday life in order to have continuous benefits from the treatment. The present study demonstrated that 830 nm LLLT was an effective form of treatment for chronic knee pain caused by knee osteoarthritis. Patients were advised to undertake training involving gentle flexion and extension of the knee.

  13. Alignment in the transverse plane, but not sagittal or coronal plane, affects the risk of recurrent patella dislocation.

    Science.gov (United States)

    Takagi, Shigeru; Sato, Takashi; Watanabe, Satoshi; Tanifuji, Osamu; Mochizuki, Tomoharu; Omori, Go; Endo, Naoto

    2017-11-17

    Abnormalities of lower extremity alignment (LEA) in recurrent patella dislocation (RPD) have been studied mostly by two-dimensional (2D) procedures leaving three-dimensional (3D) factors unknown. This study aimed to three-dimensionally examine risk factors for RPD in lower extremity alignment under the weight-bearing conditions. The alignment of 21 limbs in 15 RPD subjects was compared to the alignment of 24 limbs of 12 healthy young control subjects by an our previously reported 2D-3D image-matching technique. The sagittal, coronal, and transverse alignment in full extension as well as the torsional position of the femur (anteversion) and tibia (tibial torsion) under weight-bearing standing conditions were assessed by our previously reported 3D technique. The correlations between lower extremity alignment and RPD were assessed using multiple logistic regression analysis. The difference of lower extremity alignment in RPD between under the weight-bearing conditions and under the non-weight-bearing conditions was assessed. In the sagittal and coronal planes, there was no relationship (statistically or by clinically important difference) between lower extremity alignment angle and RPD. However, in the transverse plane, increased external tibial rotation [odds ratio (OR) 1.819; 95% confidence interval (CI) 1.282-2.581], increased femoral anteversion (OR 1.183; 95% CI 1.029-1.360), and increased external tibial torsion (OR 0.880; 95% CI 0.782-0.991) were all correlated with RPD. The tibia was more rotated relative to femur at the knee joint in the RPD group under the weight-bearing conditions compared to under the non-weight-bearing conditions (p alignment parameters in the transverse plane related to the risk of RPD, while in the sagittal and coronal plane alignment parameters did not correlate with RPD. The clinical importance of this study is that the 3D measurements more directly, precisely, and sensitively detect rotational parameters associated with RPD and

  14. Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score: A multivariable regression analysis.

    Science.gov (United States)

    Huijbregts, Henricus J T A M; Khan, Riaz J K; Fick, Daniel P; Jarrett, Olivia M; Haebich, Samantha

    2016-06-01

    Approximately 18% of the patients are dissatisfied with the result of total knee replacement. However, the relation between dissatisfaction and prosthetic alignment has not been investigated before. We retrospectively analysed prospectively gathered data of all patients who had a primary TKR, preoperative and one-year postoperative Oxford Knee Scores (OKS) and postoperative computed tomography (CT). The CT protocol measures hip-knee-ankle (HKA) angle, and coronal, sagittal and axial component alignment. Satisfaction was defined using a five-item Likert scale. We dichotomised dissatisfaction by combining '(very) dissatisfied' and 'neutral/not sure'. Associations with dissatisfaction and change in OKS were calculated using multivariable logistic and linear regression models. 230 TKRs were implanted in 105 men and 106 women. At one year, 12% were (very) dissatisfied and 10% neutral. Coronal alignment of the femoral component was 0.5 degrees more accurate in patients who were satisfied at one year. The other alignment measurements were not different between satisfied and dissatisfied patients. All radiographic measurements had a P-value>0.10 on univariate analyses. At one year, dissatisfaction was associated with the three-months OKS. Change in OKS was associated with three-months OKS, preoperative physical SF-12, preoperative pain and cruciate retaining design. Neither mechanical axis, nor component alignment, is associated with dissatisfaction at one year following TKR. Patients get the best outcome when pain reduction and function improvement are optimal during the first three months and when the indication to embark on surgery is based on physical limitations rather than on a high pain score. 2. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Articular contact in a three-dimensional model of the knee

    NARCIS (Netherlands)

    Blankevoort, L.; Kuiper, J. H.; Huiskes, R.; Grootenboer, H. J.

    1991-01-01

    This study is aimed at the analysis of articular contact in a three-dimensional mathematical model of the human knee-joint. In particular the effect of articular contact on the passive motion characteristics is assessed in relation to experimentally obtained joint kinematics. Two basically different

  16. Muscle activity during knee-extension strengthening exercise performed with elastic tubing and isotonic resistance.

    Science.gov (United States)

    Jakobsen, Markus Due; Sundstrup, Emil; Andersen, Christoffer H; Bandholm, Thomas; Thorborg, Kristian; Zebis, Mette K; Andersen, Lars L

    2012-12-01

    While elastic resistance training, targeting the upper body is effective for strength training, the effect of elastic resistance training on lower body muscle activity remains questionable. The purpose of this study was to evaluate the EMG-angle relationship of the quadriceps muscle during 10-RM knee-extensions performed with elastic tubing and an isotonic strength training machine. 7 women and 9 men aged 28-67 years (mean age 44 and 41 years, respectively) participated. Electromyographic (EMG) activity was recorded in 10 muscles during the concentric and eccentric contraction phase of a knee extension exercise performed with elastic tubing and in training machine and normalized to maximal voluntary isometric contraction (MVC) EMG (nEMG). Knee joint angle was measured during the exercises using electronic inclinometers (range of motion 0-90°). When comparing the machine and elastic resistance exercises there were no significant differences in peak EMG of the rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM) during the concentric contraction phase. However, during the eccentric phase, peak EMG was significantly higher (ptubing (5.7±0.6) compared with knee extensions performed in training machine (5.9±0.5). Knee extensions performed with elastic tubing induces similar high (>70% nEMG) quadriceps muscle activity during the concentric contraction phase, but slightly lower during the eccentric contraction phase, as knee extensions performed using an isotonic training machine. During the concentric contraction phase the two different conditions displayed reciprocal EMG-angle patterns during the range of motion. 5.

  17. Osteoarthritis of the patella, lateral femoral condyle and posterior medial femoral condyle correlate with range of motion.

    Science.gov (United States)

    Suzuki, Takashi; Motojima, Sayaka; Saito, Shu; Ishii, Takao; Ryu, Keinosuke; Ryu, Junnosuke; Tokuhashi, Yasuaki

    2013-11-01

    The type of osteoarthritis and the degree of severity which causes restriction of knee range of motion (ROM) is still largely unknown. The objective of this study was to analyse the location and the degree of cartilage degeneration that affect knee range of motion and the connection, if any, between femorotibial angle (FTA) and knee ROM restriction. Four hundreds and fifty-six knees in 230 subjects with knee osteoarthritis undergoing knee arthroplasty were included. Articular surface was divided into eight sections, and cartilage degeneration was evaluated macroscopically during the operation. Cartilage degeneration was classified into four grades based on the degree of exposure of subchondral bone. A Pearson correlation was conducted between FTA and knee flexion angle to determine whether high a degree of FTA caused knee flexion restriction. A logistic regression analysis was also conducted to detect the locations and levels of cartilage degeneration causing knee flexion restriction. No correlation was found between FTA and flexion angle (r = -0.08). Flexion angle was not restricted with increasing FTA. Logistic regression analysis showed significant correlation between restricted knee ROM and levels of knee cartilage degeneration in the patella (odds ratio (OR) = 1.77; P = 0.01), the lateral femoral condyle (OR = 1.62; P = 0.03) and the posterior medial femoral condyle (OR = 1.80; P = 0.03). For clinical relevance, soft tissue release and osteophyte resection around the patella, lateral femoral condyle and posterior medial femoral condyle might be indicated to obtain a higher degree of knee flexion angle.

  18. Mid-sagittal plane and mid-sagittal surface optimization in brain MRI using a local symmetry measure

    DEFF Research Database (Denmark)

    Stegmann, Mikkel Bille; Skoglund, Karl; Ryberg, Charlotte

    2005-01-01

    , the mid-sagittal plane is not always planar, but a curved surface resulting in poor partitioning of the brain hemispheres. To account for this, this paper also investigates an optimization strategy which fits a thin-plate spline surface to the brain data using a robust least median of squares estimator...

  19. Clinical practice guidelines for rest orthosis, knee sleeves, and unloading knee braces in knee osteoarthritis.

    Science.gov (United States)

    Beaudreuil, Johann; Bendaya, Samy; Faucher, Marc; Coudeyre, Emmanuel; Ribinik, Patricia; Revel, Michel; Rannou, François

    2009-12-01

    To develop clinical practice guidelines concerning the use of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis. The French Physical Medicine and Rehabilitation Society (SOFMER) methodology, associating a systematic literature review, collection of everyday clinical practice, and external review by multidisciplinary expert panel, was used. Few high-level studies of bracing for knee osteoarthritis were found. No evidence exists for the effectiveness of rest orthosis. Evidence for knee sleeves suggests that they decrease pain in knee osteoarthritis, and their use is associated with subjective improvement. These actions do not appear to depend on a local thermal effect. The effectiveness of knee sleeves for disability is not demonstrated for knee osteoarthritis. Short- and mid-term follow-up indicates that valgus knee bracing decreases pain and disability in medial knee osteoarthritis, appears to be more effective than knee sleeves, and improves quality of life, knee proprioception, quadriceps strength, and gait symmetry, and decreases compressive loads in the medial femoro-tibial compartment. However, results of response to valgus knee bracing remain inconsistent; discomfort and side effects can result. Thrombophlebitis of the lower limbs has been reported with the braces. Braces, whatever kind, are infrequently prescribed in clinical practice for osteoarthritis of the lower limbs. Modest evidence exists for the effectiveness of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis, with only low level recommendations for its use. Braces are prescribed infrequently in French clinical practice for osteoarthritis of the knee. Randomized clinical trials concerning bracing in knee osteoarthritis are still necessary.

  20. Knee kinematics and kinetics in former soccer players with a 16-year-old ACL injury – the effects of twelve weeks of knee-specific training

    Directory of Open Access Journals (Sweden)

    Holmström Eva

    2007-04-01

    Full Text Available Abstract Background Training of neuromuscular control has become increasingly important and plays a major role in rehabilitation of subjects with an injury to the anterior cruciate ligament (ACL. Little is known, however, of the influence of this training on knee stiffness during loading. Increased knee stiffness occurs as a loading strategy of ACL-injured subjects and is associated with increased joint contact forces. Increased or altered joint loads contribute to the development of osteoarthritis. The aim of the study was to determine if knee stiffness, defined by changes in knee kinetics and kinematics of gait, step activity and cross-over hop could be reduced through a knee-specific 12-week training programme. Methods A 3-dimensional motion analysis system (VICON and a force plate (AMTI were used to calculate knee kinetics and kinematics before and after 12 weeks of knee-specific training in 12 males recruited from a cohort with ACL injury 16 years earlier. Twelve uninjured males matched for age, sex, BMI and activity level served as a reference group. Self-reported patient-relevant data were obtained by the KOOS questionnaire. Results There were no significant changes in knee stiffness during gait and step activity after training. For the cross-over hop, increased peak knee flexion during landing (from 44 to 48 degrees, p = 0.031 and increased internal knee extensor moment (1.28 to 1.55 Nm/kg, p = 0.017 were seen after training, indicating reduced knee stiffness. The KOOS sport and recreation score improved from 70 to 77 (p = 0.005 and was significantly correlated with the changes in knee flexion during landing for the cross-over hop (r = 0.6, p = 0.039. Conclusion Knee-specific training improved lower extremity kinetics and kinematics, indicating reduced knee stiffness during demanding hop activity. Self-reported sport and recreational function correlated positively with the biomechanical changes supporting a clinical importance of the

  1. Large Intra-Articular Anterior Cruciate Ligament Ganglion Cyst, Presenting with Inability to Flex the Knee

    Directory of Open Access Journals (Sweden)

    Jake Sloane

    2010-01-01

    Full Text Available A 41-year-old female presented with a 3-month history of gradually worsening anterior knee pain, swelling and inability to flex the knee. Magnetic resonance imaging (MRI revealed a large intra-articular cystic swelling anterior to the anterior cruciate ligament (ACL, extending into the Hoffa's infrapatellar fat pad. Following manipulation under anaesthesia and arthroscopic debridement of the cyst, the patient's symptoms were relieved with restoration of normal knee motion. ACL ganglion cysts are uncommon intra-articular pathological entities, which are usually asymptomatic and diagnosed incidentally by MRI. This is the first reported case of an ACL cyst being so large as to cause a mechanical block to knee flexion.

  2. Evaluation of the gait performance of above-knee amputees while walking with 3R20 and 3R15 knee joints

    Directory of Open Access Journals (Sweden)

    AliReza Taheri

    2012-01-01

    Full Text Available Background: The performance of the subjects with above-knee amputation is noticeably poorer than normal subjects. Various types of components have been designed to compensate their performance. Among various prosthetic components, the knee joint has great influence on the function. Two types of knee joints (3R15, 3R20 have been used broadly for above-knee prostheses. However, there is not enough research to highlight the influence of these joints on the gait performance of the subjects. Therefore, an aim of this research was to investigate the performance of the above-knee amputees while walking with 3R15 and 3R20 knee joints. Materials and Methods: 7 above-knee amputees were recruited in this research study. They were asked to walk with a comfortable speed to investigate the gait function of the subjects with 3 cameras 3D motion analysis system (Kinematrix system. The difference between the performances of the subjects with these joints was compared by use of paired t-test. Results: The results of this study showed that, the performances of the subjects with 3R20 were better than that with 3R15. The walking speed of the subjects with 3R20 was 66.7 m/min compared to 30.4 m/min (P-value = 0.045. Moreover; the symmetry of walking with 3R20 was more than that with 3R15, based on the spatio- temporal gait parameters values (P-value <0.05. Conclusion: The difference between the performances of the subjects with 3R20 and 3R15 knee joints was related to the walking speed, which improved while walking with 3R20 joint.

  3. Ipsilateral Floating Hip and Floating Knee – A Rare Entity

    Directory of Open Access Journals (Sweden)

    Yashavantha Kumar

    2013-04-01

    Full Text Available Introduction: Ipsilateral floating hip and floating knee are very rare injuries. These injuries so uncommon that only three cases of similar kind have been reported. These injuries are due to high velocity injuries following motor vehicle accidents. Management of such complex injuries is a challenging task even in experienced hands as there are no standard treatment guidelines for such fractures. Case Report: We hereby report a 20 yr old male who sustained ipsilateral floating hip and ipsilateral floating knee injuries following motor vehicle accident. Patient was stabilized initially and later taken up for surgery. Patient was treated with interlocking nail for femur and tibia in the same sitting whereas acetabulam fracture was managed conservatively. At five months all the fractures united well with restoration of good range of motion in both hip and knee. Conclusion: Ipsilateral floating knee and floating hip are very rare injuries seen following high velocity motor vehicle accidents. There are no standard guidelines for treatment of those fractures as only a few cases of similar kind have been reported in literature. Early fixation and aggressive mobilization ensures fracture union and fewer complications. Keywords: Floating hip, Floating Knee, Ipsilateral.

  4. EFFICACY OF KINESIO-TAPING VERSUS PHONOPHORESIS ON KNEE OSTEOARTHRITIS: AN EXPERIMENTAL STUDY

    Directory of Open Access Journals (Sweden)

    Magda Gaid Sedhom

    2016-08-01

    Full Text Available Background: Osteoarthritis (OA is the most common type of joint disease. Pain is the most common symptom of knee osteoarthritis. Also it characterized by sign, symptoms of inflammation, pain, stiffness and loss of mobility. This study was conducted to explore the efficacy of kinesio taping (KT versus Aescin, Diethylamine Salicylate gel phonophoresis (PH on pain level, range of motion (ROM, and proprioceptive accuracy on mild to moderate knee OA patients. Methods: Forty females with knee OA from Outpatient Clinic of Physical Therapy Faculty participated in the study with mean age (49±5.82 years. They were randomly assigned into 2 equal groups. Group I: received Aescin, Diethylamine Salicylate gel PH with pulsed ultrasound therapy and group II received KT. All patients received hot packs and selected exercise program for four weeks; three sessions per week. Visual analogue scale was used in assessment of pain level. Electronic digital goniometer was used in assessment of knee flexion ROM. Iso-kinetic daynamometer was used in assessment of knee proprioceptive accuracy. Results: There was a significant relieving of pain perception, increasing of knee flexion ROM and improving proprioceptive accuracy in knee joint post-study in both groups. But application of Aescin, Diethylamine Salicylate gel PH had significant relieve of knee pain than KT. Conclusion: Using of Aescin, Diethylamine Salicylate gel PH is more effective than KT application in reliving knee pain in knee osteoarthritic patients.

  5. Sagittal synostosis in X-linked hypophosphatemic rickets and related diseases

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, Guido [Texas Scottish Rite Hospital, Department of Radiology, Dallas, TX (United States)

    2007-08-15

    The recent observations of two new cases of X-linked hypophosphatemic rickets associated with premature closure of the sagittal suture prompted a review of similar cases seen in this institution. To review the clinical records and skull radiographs of 28 children with hypophosphatemic rickets in order to investigate the frequency and type of craniosynostosis and other cranial vault changes seen in these conditions and to review the literature for relevant findings. Clinical and imaging records were reviewed on 28 patients with hypophosphatemic rickets, all younger than 18 years. Most patients had X-linked hypophosphatemic rickets and a few had autosomal-dominant hypophosphatemic rickets or were non-familial cases. Of the 28 patients, 13 had sagittal synostosis. Dolichocephaly was present in ten patients. The configuration of the cranial vault in some of these ten patients with dolichocephaly varied somewhat from that seen in nonsyndromic sagittal synostosis. In one patient, a Chiari I malformation was demonstrated by MRI. In another patient with increased intracranial pressure the sagittal suture closure was associated with lambdoidal synostosis. Dolichocephaly was not present in three patients, suggesting that the synostosis started later than in the other patients, probably in the second year of life, a period of slower brain growth than in the first year. The two patients in this group of three showed thickening and sclerosis of the cranial vault of uncertain etiology. There is an increased risk of sagittal synostosis in hypophosphatemic rickets and related diseases in children. The appearance of the cranial vault in this type of synostosis can vary from that seen in nonsyndromic synostosis. In this setting, careful clinical and imaging follow-up is warranted. (orig.)

  6. Sagittal synostosis in X-linked hypophosphatemic rickets and related diseases

    International Nuclear Information System (INIS)

    Currarino, Guido

    2007-01-01

    The recent observations of two new cases of X-linked hypophosphatemic rickets associated with premature closure of the sagittal suture prompted a review of similar cases seen in this institution. To review the clinical records and skull radiographs of 28 children with hypophosphatemic rickets in order to investigate the frequency and type of craniosynostosis and other cranial vault changes seen in these conditions and to review the literature for relevant findings. Clinical and imaging records were reviewed on 28 patients with hypophosphatemic rickets, all younger than 18 years. Most patients had X-linked hypophosphatemic rickets and a few had autosomal-dominant hypophosphatemic rickets or were non-familial cases. Of the 28 patients, 13 had sagittal synostosis. Dolichocephaly was present in ten patients. The configuration of the cranial vault in some of these ten patients with dolichocephaly varied somewhat from that seen in nonsyndromic sagittal synostosis. In one patient, a Chiari I malformation was demonstrated by MRI. In another patient with increased intracranial pressure the sagittal suture closure was associated with lambdoidal synostosis. Dolichocephaly was not present in three patients, suggesting that the synostosis started later than in the other patients, probably in the second year of life, a period of slower brain growth than in the first year. The two patients in this group of three showed thickening and sclerosis of the cranial vault of uncertain etiology. There is an increased risk of sagittal synostosis in hypophosphatemic rickets and related diseases in children. The appearance of the cranial vault in this type of synostosis can vary from that seen in nonsyndromic synostosis. In this setting, careful clinical and imaging follow-up is warranted. (orig.)

  7. The X-ray and MRI diagnosis of osteochondritis dissecans in the knee joint

    International Nuclear Information System (INIS)

    Ge Xihong; Wang Bin; Sun Xihe; Chang Guanghui

    2002-01-01

    Objective: To investigate the X-ray and MRI manifestations of osteochondritis dissecans (OCD) and to compare the sensitivity of detection among different sequences. Methods: Thirty-six OCD cases (thirty-eight knees) with complete data were selected and analyzed. The sagittal and coronal images were acquired on T 1 WI, T 2 WI, PDWI and FLASH T 2 WI. MRI manifestations were analyzed retrospectively with double blind contrast method. The radiography were obtained on the same day. The sensitivity of detection among different sequences was also compared. Results: (1) The medial femoral condyle was the most commonly affected location in the knee (63.2%). The proportion of classical type, expanded type, and infero-central type was 55.3%, 15.8% and 28.9%, respectively. (2) On radiographs, the lesions typically appeared as a well circumscribed area of sclerotic subchondral bone separated from the remainder of the epiphysis by a radiolucent line. (3) Subchondral bone lesion was displayed as small and crescent-shaped (n = 38) on the sagittal image and as wedge (14) or short bar (24) shape on coronal image. The signal of the lesion was hypointense or isointense on T 1 WI, surrounded by a hypointense or hyperintense (FLASH T 2 WI, T 2 WI) line. The subchondral plate disappeared or became thinner. Interruption or disappearance of the hyaline cartilage could be seen sometimes. (4) The detection rate on T 1 WI was higher than that of PDWI, T 2 WI and FLASH T 2 WI. Conclusion: (1) Osteochondritis dissecans has specific X-ray and MRI manifestations. The abnormality of the hyaline cartilage and the subchondral bone can be displayed by MRI. Thus a proper diagnosis can be made. (2) The detection rate on T 1 WI is higher than that of PDWI, T 2 WI and FLASH T 2 WI

  8. Meniscus tears of the knee: Postarthrogram high resolution CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyoung; Do, Young Soo; You, Jin Jong; Gong, Jae Chul; Kim, Hyung Jin; Chung, Sung Hoon

    1990-01-01

    Thirty-eight knees with clinically suspected meniscal tears were examined with high resolution computed tomography(HRCT) immediately following double contrast arthrography. All subsequently underwent arthroscopy. The findings of postarthrogram HRCT and arthroscopy were compared to evaluated the usefulness of postarthrogram HRCT in diagnosis of the meniscal tears. The sensitivity, specificity and accuracy of HRCT were 96.2%. 83.3% and 92.1% respectively. The anatomic details of the meniscal tears were clearly visible on the HRCT scans. Sagittal and coronal reformation views well visualized the horizontal tears and the relationship of torn meniscal fragments, and well differential the peripheral tears from the synovial recess. Our result indicate that postarthrogram HRCT not only is a sensitive and effective method for the detection and characterization of the meniscal tears, but also provides arthroscopists with the appropriate surgical plans

  9. Kinematics of the trunk and the lower extremities during restricted and unrestricted squats.

    Science.gov (United States)

    List, Renate; Gülay, Turgut; Stoop, Mirjam; Lorenzetti, Silvio

    2013-06-01

    Squatting is a common strength training exercise used for rehabilitation, fitness training, and in preparation for competition. Knowledge about the loading and the motion of the back during the squat exercise is crucial to avoid overuse or injury. The aim of this study was the measurement and comparison of the kinematics of the lower leg, trunk, and spine during unrestricted and restricted (knees are not allowed beyond toes) squats. A total of 30 subjects performed unrestricted and restricted barbell squats with an extra load of 0, 25, and 50% bodyweight. Motion was tracked using a 12-camera Vicon system. A newly developed marker set with 24 trunk and 7 pelvic markers allowed us to measure 3D segmental kinematics between the pelvic and the lumbar regions, between the lumbar and the thoracic segments, and the sagittal curvatures of the lumbar and the thoracic spine. In an unrestricted squat, the angle of the knee is larger and the range of motion (ROM) between the lumbar and the thoracic segments is significantly smaller compared with a restricted squat (p squats. The unrestricted execution of a squat leads to a larger ROM in the knee and smaller changes in the curvature of the thoracic spine and the range of smaller segmental motions within the trunk. This execution in turn leads to lower stresses in the back. To strengthen the muscles of the leg, the unrestricted squat may be the best option for most people. Thus, practitioners should not be overly strict in coaching against anterior knee displacement during performance of the squat.

  10. Multi-joint postural behavior in patients with knee osteoarthritis.

    Science.gov (United States)

    Turcot, Katia; Sagawa, Yoshimasa; Hoffmeyer, Pierre; Suvà, Domizio; Armand, Stéphane

    2015-12-01

    Previous studies have demonstrated balance impairment in patients with knee osteoarthritis (OA). Although it is currently accepted that postural control depends on multi-joint coordination, no study has previously considered this postural strategy in patients suffering from knee OA. The objectives of this study were to investigate the multi-joint postural behavior in patients with knee OA and to evaluate the association with clinical outcomes. Eighty-seven patients with knee OA and twenty-five healthy elderly were recruited to the study. A motion analysis system and two force plates were used to investigate the joint kinematics (trunk and lower body segments), the lower body joint moments, the vertical ground reaction force ratio and the center of pressure (COP) during a quiet standing task. Pain, functional capacity and quality of life status were also recorded. Patients with symptomatic and severe knee OA adopt a more flexed posture at all joint levels in comparison with the control group. A significant difference in the mean ratio was found between groups, showing an asymmetric weight distribution in patients with knee OA. A significant decrease in the COP range in the anterior-posterior direction was also observed in the group of patients. Only small associations were observed between postural impairments and clinical outcomes. This study brings new insights regarding the postural behavior of patients with severe knee OA during a quiet standing task. The results confirm the multi-joint asymmetric posture adopted by this population. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. The relevance of ligament balancing in total knee arthroplasty: how important is it? A systematic review of the literature

    OpenAIRE

    Babazadeh, Sina; Stoney, James D.; Lim, Keith; Choong, Peter F.M.

    2009-01-01

    Ligament balancing affects many of the postoperative criteria for a successful knee replacement. A balanced knee contributes to improved alignment and stability. Ligament balancing helps reduce wear and loosening of the joint. A patient with a balanced knee is more likely to have increased range of motion and proprioception, and decreased pain. All these factors help minimize the need for revision surgery. Complications associated with ligament balancing can include instability caused by over...

  12. Impact of knee support and shape of tabletop on rectum and prostate position

    International Nuclear Information System (INIS)

    Steenbakkers, Roel; Duppen, Joop C.; Betgen, Anja; Lotz, Heidi; Remeijer, Peter; Fitton, Isabelle; Nowak, Peter; Herk, Marcel van; Rasch, Coen

    2004-01-01

    Purpose: To evaluate the impact of different tabletops with or without a knee support on the position of the rectum, prostate, and bulb of the penis; and to evaluate the effect of these patient-positioning devices on treatment planning. Methods and materials: For 10 male volunteers, five MRI scans were made in four different positions: on a flat tabletop with knee support, on a flat tabletop without knee support, on a rounded tabletop with knee support, and on a rounded tabletop without knee support. The fifth scan was in the same position as the first. With image registration, the position differences of the rectum, prostate, and bulb of the penis were measured at several points in a sagittal plane through the central axis of the prostate. A planning target volume was generated from the delineated prostates with a margin of 10 mm in three dimensions. A three-field treatment plan with a prescribed dose of 78 Gy to the International Commission on Radiation Units and Measurements point was automatically generated from each planning target volume. Dose-volume histograms were calculated for all rectal walls. Results: The shape of the tabletop did not affect the rectum and prostate position. Addition of a knee support shifted the anterior and posterior rectal walls dorsally. For the anterior rectal wall, the maximum dorsal shift was 9.9 mm (standard error of the mean [SEM] 1.7 mm) at the top of the prostate. For the posterior rectal wall, the maximum dorsal shift was 10.2 mm (SEM 1.5 mm) at the middle of the prostate. Therefore, the rectal filling was pushed caudally when a knee support was added. The knee support caused a rotation of the prostate around the left-right axis at the apex (i.e., a dorsal rotation) by 5.6 deg (SEM 0.8 deg ) and shifts in the caudal and dorsal directions of 2.6 mm (SEM 0.4 cm) and 1.4 mm (SEM 0.6 mm), respectively. The position of the bulb of the penis was not influenced by the use of a knee support or rounded tabletop. The volume of the

  13. Sagittal synostosis: I. Preoperative morphology of the skull

    DEFF Research Database (Denmark)

    Guimaraes-Ferreira, J.; Gewalli, F.; David, L.

    2006-01-01

    The aim of this study was to characterise the preoperative morphology of the skull in sagittal synostosis in an objective and quantified way. The shapes of the skulls of 105 patients with isolated premature synostosis of the sagittal suture ( SS group) were studied and compared with those......, skull base, and orbit ( 42 in the lateral and 46 in the frontal projections), the production of plots of mean shape for each group, and the intergroup comparison of a series of 81 variables ( linear distance between selected landmarks, and angles defined by groups of three landmarks). Data from...... skull width. Comparison of the mean values of an SS subgroup to age-matched normative data showed a longer (p differ significantly...

  14. Position of the quadriceps actuator influences knee loads during simulated squat testing.

    Science.gov (United States)

    Hast, Michael W; Piazza, Stephen J

    2018-05-17

    The "Oxford Rig" cadaveric simulator permits researchers and clinicians to study knee mechanics during a simulated squatting motion. The motion of the lower limb in the Oxford Rig is typically controlled by a single actuator that applies tension to the quadriceps tendon. The location of the quadriceps actuator, however, has differed across published descriptions of the Oxford Rig. Actuators have been placed on the femur and pelvis, and on "grounded" locations external to the specimen, but the consequences of this placement for knee kinematics and kinetics are unknown. The purpose of this study was to examine these effects using a validated computational musculoskeletal model. When the actuator was placed on the femur or pelvis, forces realistically increased with knee flexion, with quadriceps and patellofemoral contact forces exceeding 2000 N and 3000 N, respectively, at 100° flexion. When the actuator was grounded, however, forces were substantially reduced and did not monotonically increase with flexion. Articular joint contact forces were not strongly influenced by changing the location of the actuator from the femur to the pelvis, with small RMS differences in quadriceps forces (48.2 N), patellofemoral forces (83.6 N), and tibiofemoral forces (58.9 N) between these conditions. The location of the actuator did not substantially affect knee kinematics. The results of this study suggest that the quadriceps actuator of the Oxford Rig should be attached to either the femur or the pelvis when the goal is to make realistic estimates of quadriceps forces and articular contact forces within the knee joint. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Training intensity and sagittal curvature of the spine in male and female artistic gymnasts.

    Science.gov (United States)

    Sanz-Mengibar, Jose M; Sainz-de-Baranda, Pilar; Santonja-Medina, Fernando

    2018-04-01

    Specific adaptations of the spine in the sagittal plane have been described according to different sports disciplines. The goal of this study was to describe the integrative diagnosis of the sagittal morphotype of the spine in male and female artistic gymnasts. Forty-eight gymnasts were measured with an inclinometer. Thoracic and lumbar curves were quantified in standing position, in Sit and Reach and Slump Sitting in order to assess the sagittal spine posture and analyze if adaptations were related to training intensity. Correlation values of the sagittal plane spine measurements showed significantly increased thoracic kyphosis in men (-0.445, Partistic gymnastics; however, this sport seems to cause specific adaptations in postural hypolordosis, functional thoracic kyphosis and lumbar kyphotic attitude during sitting and trunk flexion. The implications of the functional adaptations observed in our results may require a preventive intervention in male and female artistic gymnasts can be assessed with the integrative diagnosis of the sagittal morphotype of the spine.

  16. Effect of knee joint icing on knee extension strength and knee pain early after total knee arthroplasty: a randomized cross-over study

    DEFF Research Database (Denmark)

    Holm, Bente; Husted, Henrik; Kehlet, Henrik

    2012-01-01

    Objective: To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty.Design: A prospective, single-blinded, randomized, cross-over study.Setting: A fast-track orthopaedic arthroplasty unit at a university hospital.......Participants: Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty.Interventions: The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30...... minutes of elbow icing (control treatment). The order of treatments was randomized.Main outcome measures: Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments...

  17. The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty.

    Science.gov (United States)

    Inoue, Shinji; Akagi, Masao; Asada, Shigeki; Mori, Shigeshi; Zaima, Hironori; Hashida, Masahiko

    2016-09-01

    Medial tibial condylar fractures (MTCFs) are a rare but serious complication after unicompartmental knee arthroplasty. Although some surgical pitfalls have been reported for MTCFs, it is not clear whether the varus/valgus tibial inclination contributes to the risk of MTCFs. We constructed a 3-dimensional finite elemental method model of the tibia with a medial component and assessed stress concentrations by changing the inclination from 6° varus to 6° valgus. Subsequently, we repeated the same procedure adding extended sagittal bone cuts of 2° and 10° in the posterior tibial cortex. Furthermore, we calculated the bone volume that supported the tibial component, which is considered to affect stress distribution in the medial tibial condyle. Stress concentrations were observed on the medial tibial metaphyseal cortices and on the anterior and posterior tibial cortices in the corner of cut surfaces in all models; moreover, the maximum principal stresses on the posterior cortex were larger than those on the anterior cortex. The extended sagittal bone cuts in the posterior tibial cortex increased the stresses further at these 3 sites. In the models with a 10° extended sagittal bone cut, the maximum principal stress on the posterior cortex increased as the tibial inclination changed from 6° varus to 6° valgus. The bone volume decreased as the inclination changed from varus to valgus. In this finite element method, the risk of MTCFs increases with increasing valgus inclination of the tibial component and with increased extension of the sagittal cut in the posterior tibial cortex. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Sagittal imbalance in patients with lumbar spinal stenosis and outcomes after simple decompression surgery.

    Science.gov (United States)

    Shin, E Kyung; Kim, Chi Heon; Chung, Chun Kee; Choi, Yunhee; Yim, Dahae; Jung, Whei; Park, Sung Bae; Moon, Jung Hyeon; Heo, Won; Kim, Sung-Mi

    2017-02-01

    Lumbar spinal stenosis (LSS) is the most common lumbar degenerative disease, and sagittal imbalance is uncommon. Forward-bending posture, which is primarily caused by buckling of the ligamentum flavum, may be improved via simple decompression surgery. The objectives of this study were to identify the risk factors for sagittal imbalance and to describe the outcomes of simple decompression surgery. This is a retrospective nested case-control study PATIENT SAMPLE: This was a retrospective study that included 83 consecutive patients (M:F=46:37; mean age, 68.5±7.7 years) who underwent decompression surgery and a minimum of 12 months of follow-up. The primary end point was normalization of sagittal imbalance after decompression surgery. Sagittal imbalance was defined as a C7 sagittal vertical axis (SVA) ≥40 mm on a 36-inch-long lateral whole spine radiograph. Logistic regression analysis was used to identify the risk factors for sagittal imbalance. Bilateral decompression was performed via a unilateral approach with a tubular retractor. The SVA was measured on serial radiographs performed 1, 3, 6, and 12 months postoperatively. The prognostic factors for sagittal balance recovery were determined based on various clinical and radiological parameters. Sagittal imbalance was observed in 54% (45/83) of patients, and its risk factors were old age and a large mismatch between pelvic incidence and lumbar lordosis. The 1-year normalization rate was 73% after decompression surgery, and the median time to normalization was 1 to 3 months. Patients who did not experience SVA normalization exhibited low thoracic kyphosis (hazard ratio [HR], 1.04; 95% confidence interval [CI], 1.02-1.10) (pimbalance was observed in more than 50% of LSS patients, but this imbalance was correctable via simple decompression surgery in 70% of patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. An examination of the degrees of freedom of human jaw motion in speech and mastication.

    Science.gov (United States)

    Ostry, D J; Vatikiotis-Bateson, E; Gribble, P L

    1997-12-01

    The kinematics of human jaw movements were assessed in terms of the three orientation angles and three positions that characterize the motion of the jaw as a rigid body. The analysis focused on the identification of the jaw's independent movement dimensions, and was based on an examination of jaw motion paths that were plotted in various combinations of linear and angular coordinate frames. Overall, both behaviors were characterized by independent motion in four degrees of freedom. In general, when jaw movements were plotted to show orientation in the sagittal plane as a function of horizontal position, relatively straight paths were observed. In speech, the slopes and intercepts of these paths varied depending on the phonetic material. The vertical position of the jaw was observed to shift up or down so as to displace the overall form of the sagittal plane motion path of the jaw. Yaw movements were small but independent of pitch, and vertical and horizontal position. In mastication, the slope and intercept of the relationship between pitch and horizontal position were affected by the type of food and its size. However, the range of variation was less than that observed in speech. When vertical jaw position was plotted as a function of horizontal position, the basic form of the path of the jaw was maintained but could be shifted vertically. In general, larger bolus diameters were associated with lower jaw positions throughout the movement. The timing of pitch and yaw motion differed. The most common pattern involved changes in pitch angle during jaw opening followed by a phase predominated by lateral motion (yaw). Thus, in both behaviors there was evidence of independent motion in pitch, yaw, horizontal position, and vertical position. This is consistent with the idea that motions in these degrees of freedom are independently controlled.

  20. Magnetic Resonance Imaging based Cartilage Loss in Painful Contra-Lateral Knees with and without Radiographic Joint Space Narrowing – Data from the Osteoarthritis Initiative (OAI)

    Science.gov (United States)

    Eckstein, Felix; Benichou, Olivier; Wirth, Wolfgang; Nelson, David R; Maschek, Susanne; Hudelmaier, Martin; Kwoh, C. Kent; Guermazi, Ali; Hunter, David

    2010-01-01

    Objective Magnetic resonance imaging (MRI) was used to assess whether knees with advanced radiographic disease (medial joint space narrowing = mJSN) encounter greater longitudinal cartilage loss than contra-lateral knees with earlier disease (no or less mJSN). Methods Participants were selected from 2678 cases in the Osteoarthritis Initiative, based on exhibition of bilateral pain, BMI>25, mJSN in one knee, no or less mJSN in the contra-lateral knee, and no lateral JSN in both knees. 80 participants (age 60.6±9.1 yrs) fulfilled these criteria. Medial tibial and femoral cartilage morphology was analyzed from baseline and 1-year follow-up sagittal DESSwe 3 Tesla MRI of both knees, by experienced readers blinded to the timepoint and mJSN status. Results Knees with more radiographic mJSN displayed greater medial cartilage loss (-80 μm), assessed by MRI, than contra-lateral knees with less mJSN (-57μm). The difference reached statistical significance in participants with mJSN grade 2 or 3 (p=0.005 to p=0.08), but not in participants with mJSN grade 1 (p=0.28 to 0.98). In knees with more mJSN, cartilage loss increased with higher grades of mJSN (p=0.003 in the medial femur). Knees with mJSN grade 2 or 3 displayed greater cartilage loss in the weight-bearing medial femur than in the posterior femur or in the medial tibia (p=0.048). Conclusion Knees with advanced mJSN displayed greater cartilage loss than contra-lateral knees with less mJSN. These data suggest that radiography can be used to stratify fast structural progressors, and that MRI cartilage thickness loss is more pronounced at advanced radiographic disease stage. PMID:19714595

  1. Accuracy of a Custom Physical Activity and Knee Angle Measurement Sensor System for Patients with Neuromuscular Disorders and Gait Abnormalities

    Directory of Open Access Journals (Sweden)

    Frank Feldhege

    2015-05-01

    Full Text Available Long-term assessment of ambulatory behavior and joint motion are valuable tools for the evaluation of therapy effectiveness in patients with neuromuscular disorders and gait abnormalities. Even though there are several tools available to quantify ambulatory behavior in a home environment, reliable measurement of joint motion is still limited to laboratory tests. The aim of this study was to develop and evaluate a novel inertial sensor system for ambulatory behavior and joint motion measurement in the everyday environment. An algorithm for behavior classification, step detection, and knee angle calculation was developed. The validation protocol consisted of simulated daily activities in a laboratory environment. The tests were performed with ten healthy subjects and eleven patients with multiple sclerosis. Activity classification showed comparable performance to commercially available activPAL sensors. Step detection with our sensor system was more accurate. The calculated flexion-extension angle of the knee joint showed a root mean square error of less than 5° compared with results obtained using an electro-mechanical goniometer. This new system combines ambulatory behavior assessment and knee angle measurement for long-term measurement periods in a home environment. The wearable sensor system demonstrated high validity for behavior classification and knee joint angle measurement in a laboratory setting.

  2. Extracting time-frequency feature of single-channel vastus medialis EMG signals for knee exercise pattern recognition.

    Directory of Open Access Journals (Sweden)

    Yi Zhang

    Full Text Available The EMG signal indicates the electrophysiological response to daily living of activities, particularly to lower-limb knee exercises. Literature reports have shown numerous benefits of the Wavelet analysis in EMG feature extraction for pattern recognition. However, its application to typical knee exercises when using only a single EMG channel is limited. In this study, three types of knee exercises, i.e., flexion of the leg up (standing, hip extension from a sitting position (sitting and gait (walking are investigated from 14 healthy untrained subjects, while EMG signals from the muscle group of vastus medialis and the goniometer on the knee joint of the detected leg are synchronously monitored and recorded. Four types of lower-limb motions including standing, sitting, stance phase of walking, and swing phase of walking, are segmented. The Wavelet Transform (WT based Singular Value Decomposition (SVD approach is proposed for the classification of four lower-limb motions using a single-channel EMG signal from the muscle group of vastus medialis. Based on lower-limb motions from all subjects, the combination of five-level wavelet decomposition and SVD is used to comprise the feature vector. The Support Vector Machine (SVM is then configured to build a multiple-subject classifier for which the subject independent accuracy will be given across all subjects for the classification of four types of lower-limb motions. In order to effectively indicate the classification performance, EMG features from time-domain (e.g., Mean Absolute Value (MAV, Root-Mean-Square (RMS, integrated EMG (iEMG, Zero Crossing (ZC and frequency-domain (e.g., Mean Frequency (MNF and Median Frequency (MDF are also used to classify lower-limb motions. The five-fold cross validation is performed and it repeats fifty times in order to acquire the robust subject independent accuracy. Results show that the proposed WT-based SVD approach has the classification accuracy of 91.85%±0

  3. Does post-operative knee awareness differ between knees in bilateral simultaneous total knee arthroplasty? Predictors of high or low knee awareness

    DEFF Research Database (Denmark)

    Nielsen, Katrine Abildgaard; Thomsen, Morten Grove; Latifi, Roshan

    2016-01-01

    PURPOSE: To evaluate the difference in post-operative knee awareness between knees in patients undergoing bilateral simultaneous total knee arthroplasty (TKA) and to assess factors predicting high or low knee awareness. METHODS: This study was conducted on 99 bilateral simultaneous TKAs performed...... at our institution from 2008 to 2012. All patients received one set of questionnaires [Forgotten Joint Score (FJS) and Oxford Knee Score (OKS)] for each knee. Based on the FJS, the patients' knees were divided into two groups: "best" and "worst" knees. The median of the absolute difference in FJS and OKS...... within each patient was calculated. Multivariate linear regression was performed to identify factors affecting FJS. RESULTS: The difference between knees was 1 point (CI 0-5) for the FJS and 1 point (CI 0-2) for the OKS. The FJS for females increased (decreasing awareness) with increasing age. Males had...

  4. Total knee arthroplasty for severe valgus knee deformity.

    Science.gov (United States)

    Zhou, Xinhua; Wang, Min; Liu, Chao; Zhang, Liang; Zhou, Yixin

    2014-01-01

    Primary total knee arthroplasty (TKA) in severe valgus knees may prove challenging, and choice of implant depends on the severity of the valgus deformity and the extent of soft-tissue release. The purpose of this study was to review 8 to 11 years (mean, 10 years) follow-up results of primary TKA for varient-III valgus knee deformity with use of different type implants. Between January 2002 and January 2005, 20 women and 12 men, aged 47 to 63 (mean, 57.19 ± 6.08) years old, with varient-III valgus knees underwent primary TKA. Of the 32 patients, 37 knees had varient-III deformities. Pie crusting was carefully performed with small, multiple inside-out incisions, bone resection balanced the knee in lieu of soft tissue releases that were not used in the series. Cruciate-retaining knees (Gemini MKII, Link Company, Germany) were used in 13 knees, Genesis II (Simth & Nephew Company, USA) in 14 knees, and hinged knee (Endo-Model Company, Germany) in 10 knees. In five patients with bilateral variant-III TKAs, three patients underwent 1-stage bilateral procedures, and two underwent 2-stage procedures. All implants were cemented and the patella was not resurfaced. The Hospital for Special Surgery (HSS) knee score was assessed. Patients were followed up from 8 to 11 years. The mean HSS knee score were improved from 50.33 ± 11.60 to 90.06 ± 3.07 (P managed with rivaroxaban and thrombo-embolic deterrent stockings. There was no incidence of pulmonary embolism. Post-operative patient satisfaction was 80.7 ± 10.4 points in the groups. Prosthetic survival rate was 100% at mean 10 years postoperative. Not only hinged implants can be successfully used in variant-III valgus knees. As our results show, if proper ligament balancing techniques are used and proper ligament balance is attained, the knee may not require the use of a more constrained components. Our results also present alternative implant choices for severe knee deformities.

  5. The Influence of Natural Head Position on the Cervical Sagittal Alignment

    Directory of Open Access Journals (Sweden)

    Kuan Wang

    2017-01-01

    Full Text Available Introduction. This study investigated the relationship between the parameters related to the natural head position and cervical segmental angles and alignment of patients with neck pain. Material and Methods. The lateral radiographs of the cervical spine were collected from 103 patients and were used to retrospectively analyze the correlation between the natural head position, cervical local sagittal angles, and alignment. Sagittal measurements were as follows: cervical curvature classification, slope of McGregor’s line (McGS, local sagittal angles (C0–C2 angle, C2–C5 angle, C5–C7 angle, and C2–C7 angle, T1 slope, center of gravity of the head to sagittal vertical axis (CG–C7 SVA, and local sagittal alignment (C0–C2 SVA and C2–C7 SVA. Results. McGS was significantly correlated to C0–C2 angle (r=0.57, C0–C2 SVA (r=−0.53, C2–C7 SVA (r=−0.28, and CG–C7 SVA (r=−0.47. CG–C7 SVA was also significantly correlated to curvature type (r=0.27, C5–C7 angle (r=−0.37, and C2–C7 angle (r=−0.39. Conclusions. A backward shift with an extended head position may accompany a relatively normal curvature of the cervical spine. The effect of posture control in relieving abnormal mechanical state of the cervical spine needs to be further confirmed by biomechanical analysis.

  6. A study on MR images of the articular cartilage in medial-type osteoarthritis of the knee

    International Nuclear Information System (INIS)

    Miyazaki, Hiroyuki; Ishii, Yoshiaki; Hayashi, Mitsutoshi; Kotani, Akihiro

    2001-01-01

    Changes in the articular cartilage of 88 knees of 73 cases (age range 40-78) diagnosed clinically and radiologically as OA (osteoarthritis) were studied by obtaining fat-suppressed MR images of the knee. On 27 knees out of the 88, moreover, macroscopic observation was performed to make a comparative study between the directly-observed findings and MR findings. Fat-suppressed MR images were obtained sagittally by 3D-FLASH (fast low angle shot) sequence. The examined regions consisted of the following 4 sites; the medial condyle of the femur, its lateral condyle, the medial condyle of the tibia, and its lateral condyle. The revealed conditions of the cartilage were morphologically classified into 4 Stages. The evidence of cartilage defect on MR images was most frequently found at the medial condyle of the femur, with the medial condyle of the tibia, the lateral condyle of the femur, and the lateral condyle of the tibia following in a less frequent order. Fat-suppressed MRI's sensitivity to cartilage defect against macroscopy was 94.5%, specificity 95.4%, and accuracy 95.2%. MR imaging using fat-suppression can reveal cartilaginous degeneration and defect so well that this technique provides an important indication for selecting a proper method of treatment. (author)

  7. Preserving the PCL during the tibial cut in total knee arthroplasty.

    Science.gov (United States)

    Cinotti, G; Sessa, P; Amato, M; Ripani, F R; Giannicola, G

    2017-08-01

    Previous studies have shown that the PCL insertion may be damaged during the tibial cut performed in total knee arthroplasty. We investigated the maximum thickness of a tibial cut that preserves the PCL insertion and to what extent the posterior slope of the tibial cut and that of the patient's tibial plateaus affect the outcome. MR images of 83 knees were analysed. The maximum thickness of a tibial cut that preserves the PCL using a posterior slope of 0°, 3°, 5° and parallel to the patient's slope of the tibial plateau, was evaluated. Correlations between the results and the degrees of the posterior slope of the patient's tibial plateaus were also investigated. The maximum thickness of a tibial cut that preserves the entire PCL insertion was, on average, 5.5, 4.7, 4.2 and 3.1 mm when a posterior slope of 0°, 3°, 5° and parallel to the patients' tibial plateaus was used, respectively. When the 25th percentile was considered, the maximum thickness of a tibial cut that preserved the PCL was 4 and 3 mm with a tibial cut of 0° and 5° of posterior slope, respectively. The maximum thickness of a tibial cut that preserved the PCL was significantly greater in patients with a sagittal slope of the tibial plateaus more than 8° than in those with a sagittal slope less than 8°. In cruciate retaining implants, the PCL insertion may be spared in the majority of patients by performing a tibial cut of 4 mm, or even less when a posterior slope of 3°-5° is used. The clinical relevance of our study is that the execution of a conservative tibial cut, followed by a second tibial resection to achieve the thickness required for the tibial component to be implanted, may be an alternative technique to spare the PCL in CR TKA. II.

  8. Spontaneous Improvement of Compensatory Knee Flexion After Surgical Correction of Mismatch Between Pelvic Incidence and Lumbar Lordosis.

    Science.gov (United States)

    Cheng, Xiaofei; Zhang, Feng; Wu, Jigong; Zhu, Zhenan; Dai, Kerong; Zhao, Jie

    2016-08-15

    A retrospective study. The aim of this study was to investigate the correlation between pelvic incidence (PI) and lumbar lordosis (LL) mismatch and knee flexion during standing in patients with lumbar degenerative diseases and to examine the effects of surgical correction of the PI-LL mismatch on knee flexion. Only several studies focused on knee flexion as a compensatory mechanism of the PI-LL mismatch. Little information is currently available on the effects of lumbar correction on knee flexion in patients with the PI-LL mismatch. A group of patients with lumbar degenerative diseases were divided into PI-LL match group (PI-LL ≤ 10°) and PI-LL mismatch group (PI-LL > 10°). A series of radiographic parameters and knee flexion angle (KFA) were compared between the two groups. The PI-LL mismatch group was further subdivided into operative and nonoperative group. The changes in KFA with PI-LL were examined. The PI-LL mismatch group exhibited significantly greater sagittal vertical axis (SVA), pelvic tilt (PT) and KFA, and smaller LL, thoracic kyphosis (TK), and sacral slope than the PI-LL match group. PI-LL, LL, PI, SVA, and PT were significantly correlated with KFA in the PI-LL mismatch group. From baseline to 6-month follow-up, all variables were significantly different in the operative group with the exception of PI, although there was no significant difference in any variable in the nonoperative group. The magnitude of surgical correction in the PI-LL mismatch was significantly correlated with the degree of spontaneous changes in KFA, PT, and TK. The PI-LL mismatch would contribute to compensatory knee flexion during standing in patients with lumbar degenerative disease. Surgical correction of the PI-LL mismatch could lead to a spontaneous improvement of compensatory knee flexion. The degree of improvement in knee flexion depends in part on the amount of correction in the PI-LL mismatch. 3.

  9. Case-related factors affecting cutting errors of the proximal tibia in total knee arthroplasty assessed by computer navigation.

    Science.gov (United States)

    Tsukeoka, Tadashi; Tsuneizumi, Yoshikazu; Yoshino, Kensuke; Suzuki, Mashiko

    2018-05-01

    The aim of this study was to determine factors that contribute to bone cutting errors of conventional instrumentation for tibial resection in total knee arthroplasty (TKA) as assessed by an image-free navigation system. The hypothesis is that preoperative varus alignment is a significant contributory factor to tibial bone cutting errors. This was a prospective study of a consecutive series of 72 TKAs. The amount of the tibial first-cut errors with reference to the planned cutting plane in both coronal and sagittal planes was measured by an image-free computer navigation system. Multiple regression models were developed with the amount of tibial cutting error in the coronal and sagittal planes as dependent variables and sex, age, disease, height, body mass index, preoperative alignment, patellar height (Insall-Salvati ratio) and preoperative flexion angle as independent variables. Multiple regression analysis showed that sex (male gender) (R = 0.25 p = 0.047) and preoperative varus alignment (R = 0.42, p = 0.001) were positively associated with varus tibial cutting errors in the coronal plane. In the sagittal plane, none of the independent variables was significant. When performing TKA in varus deformity, careful confirmation of the bone cutting surface should be performed to avoid varus alignment. The results of this study suggest technical considerations that can help a surgeon achieve more accurate component placement. IV.

  10. To move or not to move: measurements of prostate motion by urethrography using MRI

    International Nuclear Information System (INIS)

    Mah, Dennis; Freedman, Gary; Movsas, Benjamin; Hanlon, Alexandra; Mitra, Raj; Horwitz, Eric; Pinover, Wayne; Iyer, Rajesh; Hanks, G.E.

    2001-01-01

    Purpose: Urethrography is commonly used to aid in definition of the prostate apex during CT simulation for prostate cancer. If the position of the prostate were altered by the urethrogram itself, then systematic error could be introduced into the patient's treatment. Sagittal MRI scans were acquired immediately before and after a localization urethrogram to determine the extent of displacement. Methods and Materials: Thirteen patients underwent sagittal T2-weighted fast spin echo MRI scans. Patients were scanned supine in an alpha cradle cast in the treatment position. The prostate was contoured by 3 different observers to determine the apex location on the central sagittal MRI section and the center of mass relative to an immobile bony landmark. Statistical multivariate analysis was performed to establish if there was a net displacement of the prostate (systematic error), and to determine the margin required to cover the random prostate position within a 95% confidence interval. Results: There was no significant systematic motion of either the prostate nor its apex in either the anterior-posterior or superior-inferior directions. The average motion of the prostate center of mass was 0.04±0.40 cm (1 SD) and 0.01±0.33 cm in the anterior-posterior and superior-inferior direction, respectively. The corresponding figures for location of the apex were 0.05±0.30 cm and 0.01±0.33 cm, respectively. The statistical analysis revealed that a margin of 2 mm is sufficient to cover any random motion of the prostate that could occur as a result of the urethrogram 95% of the time. Conclusion: Urethrography during CT simulation for prostate cancer does not cause significant prostate displacement or systematic error in planning and delivering external-beam radiation

  11. Knee Biomechanics During Jogging After Arthroscopic Partial Meniscectomy: A Longitudinal Study.

    Science.gov (United States)

    Hall, Michelle; Wrigley, Tim V; Metcalf, Ben R; Hinman, Rana S; Cicuttini, Flavia M; Dempsey, Alasdair R; Lloyd, David G; Bennell, Kim L

    2017-07-01

    Altered knee joint biomechanics is thought to play a role in the pathogenesis of knee osteoarthritis and has been reported in patients after arthroscopic partial meniscectomy (APM) while performing various activities. Longitudinally, understanding knee joint biomechanics during jogging may assist future studies to assess the implications of jogging on knee joint health in this population. To investigate knee joint biomechanics during jogging in patients 3 months after APM and a healthy control group at baseline and 2 years later at follow-up. Controlled laboratory study. Seventy-eight patients who underwent medial APM and 38 healthy controls underwent a 3-dimensional motion analysis during barefoot overground jogging at baseline. Sixty-four patients who underwent APM and 23 controls returned at follow-up. External peak moments (flexion and adduction) and the peak knee flexion angle during stance were evaluated for the APM leg, non-APM leg (nonoperated leg), and control leg. At baseline, the peak knee flexion angle was 1.4° lower in the APM leg compared with the non-APM leg ( P = .03). No differences were found between the moments in the APM leg compared with the control leg (all P > .05). However, the normalized peak knee adduction moment was 35% higher in the non-APM leg compared with the control leg ( P = .008). In the non-APM leg, the normalized peak knee adduction and flexion moments were higher compared with the APM leg by 16% and 10%, respectively, at baseline ( P ≤ .004). Despite the increase in the peak knee flexion moment in the APM leg compared with the non-APM leg ( P .05). Comparing the APM leg and control leg, no differences in knee joint biomechanics during jogging for the variables assessed were observed. Higher knee moments in the non-APM leg may have clinical implications for the noninvolved leg. Kinematic differences were small (~1.4°) and therefore of questionable clinical relevance. These results may facilitate future clinical research

  12. Soft Smart Garments for Lower Limb Joint Position Analysis

    Directory of Open Access Journals (Sweden)

    Massimo Totaro

    2017-10-01

    Full Text Available Revealing human movement requires lightweight, flexible systems capable of detecting mechanical parameters (like strain and pressure while being worn comfortably by the user, and not interfering with his/her activity. In this work we address such multifaceted challenge with the development of smart garments for lower limb motion detection, like a textile kneepad and anklet in which soft sensors and readout electronics are embedded for retrieving movement of the specific joint. Stretchable capacitive sensors with a three-electrode configuration are built combining conductive textiles and elastomeric layers, and distributed around knee and ankle. Results show an excellent behavior in the ~30% strain range, hence the correlation between sensors’ responses and the optically tracked Euler angles is allowed for basic lower limb movements. Bending during knee flexion/extension is detected, and it is discriminated from any external contact by implementing in real time a low computational algorithm. The smart anklet is designed to address joint motion detection in and off the sagittal plane. Ankle dorsi/plantar flexion, adduction/abduction, and rotation are retrieved. Both knee and ankle smart garments show a high accuracy in movement detection, with a RMSE less than 4° in the worst case.

  13. Soft Smart Garments for Lower Limb Joint Position Analysis.

    Science.gov (United States)

    Totaro, Massimo; Poliero, Tommaso; Mondini, Alessio; Lucarotti, Chiara; Cairoli, Giovanni; Ortiz, Jesùs; Beccai, Lucia

    2017-10-12

    Revealing human movement requires lightweight, flexible systems capable of detecting mechanical parameters (like strain and pressure) while being worn comfortably by the user, and not interfering with his/her activity. In this work we address such multifaceted challenge with the development of smart garments for lower limb motion detection, like a textile kneepad and anklet in which soft sensors and readout electronics are embedded for retrieving movement of the specific joint. Stretchable capacitive sensors with a three-electrode configuration are built combining conductive textiles and elastomeric layers, and distributed around knee and ankle. Results show an excellent behavior in the ~30% strain range, hence the correlation between sensors' responses and the optically tracked Euler angles is allowed for basic lower limb movements. Bending during knee flexion/extension is detected, and it is discriminated from any external contact by implementing in real time a low computational algorithm. The smart anklet is designed to address joint motion detection in and off the sagittal plane. Ankle dorsi/plantar flexion, adduction/abduction, and rotation are retrieved. Both knee and ankle smart garments show a high accuracy in movement detection, with a RMSE less than 4° in the worst case.

  14. Analysis of in vitro and in vivo function of total knee replacements using dynamic contact models

    Science.gov (United States)

    Zhao, Dong

    Despite the high incidence of osteoarthritis in human knee joint, its causes remain unknown. Total knee replacement (TKR) has been shown clinically to be effective in restoring the knee function. However, wear of ultra-high molecular weight polyethylene has limited the longevity of TKRs. To address these important issues, it is necessary to investigate the in vitro and in vivo function of total knee replacements using dynamic contact models. A multibody dynamic model of an AMTI knee simulator was developed. Incorporating a wear prediction model into the contact model based on elastic foundation theory enables the contact surface to take into account creep and wear during the dynamic simulation. Comparisons of the predicted damage depth, area, and volume lost with worn retrievals from a physical machine were made to validate the model. In vivo tibial force distributions during dynamic and high flexion activities were investigated using the dynamic contact model. In vivo medial and lateral contact forces experienced by a well-aligned instrumented knee implant, as well as upper and lower bounds on contact pressures for a variety of activities were studied. For all activities, the predicted medial and lateral contact forces were insensitive to the selected material model. For this patient, the load split during the mid-stance phase of gait and during stair is more equal than anticipated. The external knee adduction torque has been proposed as a surrogate measure for medial compartment load during gait. However, a direct link between these two quantities has not been demonstrated using in vivo measurement of medial compartment load. In vivo data collected from a subject with an instrumented knee implant were analyzed to evaluate this link. The subject performed five different overground gait motions (normal, fast, slow, wide, and toe out) while instrumented implant, video motion, and ground reaction data were simultaneously collected. The high correlation coefficient

  15. Prosthetic replacement of the medial meniscus in cadaveric knees - Does the prosthesis mimic the functional behavior of the native meniscus?

    NARCIS (Netherlands)

    Tienen, TG; Verdonschot, N; Heijkants, RGJC; Buma, R; Scholten, JGF; van Kampen, A; Veth, RPH

    2004-01-01

    Meniscus replacement by a polymer meniscus prosthesis in dogs resulted in generation of new meniscal tissue. Hypothesis: Optimal functioning of the prosthesis would involve realistic deformation and motion patterns of the prosthesis during knee joint motion. Study Design: Controlled laboratory

  16. Biological inspiration used for robots motion synthesis.

    Science.gov (United States)

    Zielińska, Teresa

    2009-01-01

    This work presents a biologically inspired method of gait generation. Bipedal gait pattern (for hip and knee joints) was taken into account giving the reference trajectories in a learning task. The four coupled oscillators were taught to generate the outputs similar to those in a human gait. After applying the correction functions the obtained generation method was validated using ZMP criterion. The formula suitable for real-time motion generation taking into account the positioning errors was also formulated. The small real robot prototype was tested to be able walk successfully following the elaborated motion pattern.

  17. Strategic Considerations for Effective Sagittal Resection of the Mandible to Achieve a Slim and Attractive Jawline.

    Science.gov (United States)

    Park, Sanghoon; Lee, Tae Sung

    2018-01-01

    Sagittal resection of the mandible has been widely used to reduce the width of the lower face and is usually carried out in combination with a mandibular contouring procedure. However, the surgical outcomes of this procedure are unclear because sagittal resection is rarely performed as a single procedure. The authors clarify misunderstandings regarding this procedure and introduce an improved strategic approach for sagittal resection of the mandible. Under general anesthesia, mandible contouring was performed first with a curved osteotomy, followed by sagittal resection of the outer cortex of mandible. The amount and extent of each procedure was determined in accordance with preoperative analysis. From 2012 to 2014, a consecutive series of 212 patients who underwent mandible contouring surgery without concomitant chin surgery were included in the study. A total of 189 patients underwent both mandibular contouring surgery and sagittal resection, whereas 13 underwent only sagittal resection and 10 underwent only mandibular contouring surgery. All operations were carried out successfully without any severe complications, and most patients had satisfactory aesthetic outcomes. The authors found that the sagittal resection of the mandible should be performed in accordance with the shape of the mandible to effectively reduce facial width and achieve better aesthetic outcomes for both profile and frontal views. In an outcurved-type mandible, conventional mandibular contouring may be effective alone, whereas sagittal resection focusing on removing the mandible body region is essential for incurved-type mandibles. In straight line-type mandibles, both procedures are necessary. Therapeutic, IV.

  18. Precision analysis of a multi-slice ultrasound sensor for non-invasive 3D kinematic analysis of knee joints.

    Science.gov (United States)

    Masum, Md Abdullah; Lambert, Andrew J; Pickering, Mark R; Scarvell, J M; Smith, P N

    2012-01-01

    Currently the standard clinical practice for measuring the motion of bones in a knee joint with sufficient precision involves implanting tantalum beads into the bones to act as fiducial markers prior to imaging using X-ray equipment. This procedure is invasive in nature and exposure to ionizing radiation imposes a cancer risk and the patient's movements are confined to a narrow field of view. In this paper, an ultrasound based system for non-invasive kinematic evaluation of knee joints is proposed. The results of an initial analysis show that this system can provide the precision required for non-invasive motion analysis while the patient performs normal physical activities.

  19. Quantitative MRI T2 relaxation time evaluation of knee cartilage: comparison of meniscus-intact and -injured knees after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Li, Hong; Chen, Shuang; Tao, Hongyue; Chen, Shiyi

    2015-04-01

    Associated meniscal injury is well recognized at anterior cruciate ligament (ACL) reconstruction, and it is a known risk factor for osteoarthritis. To evaluate and characterize the postoperative appearance of articular cartilage after different meniscal treatment in ACL-reconstructed knees using T2 relaxation time evaluation on MRI. Cohort study; Level of evidence, 3. A total of 62 consecutive patients who under ACL reconstruction were recruited in this study, including 23 patients undergoing partial meniscectomy (MS group), 21 patients undergoing meniscal repair (MR group), and 18 patients with intact menisci (MI group) at time of surgery. Clinical evaluation, including subjective functional scores and physical examination, was performed on the same day as the MRI examination and at follow-up times ranging from 2 to 4.2 years. The MRI multiecho sagittal images were segmented to determine the T2 relaxation time value of each meniscus and articular cartilage plate. Differences in each measurement were compared among groups. No patient had joint-line tenderness or reported pain or clicking on McMurray test or instability. There were also no statistically significant differences in functional scores or medial or lateral meniscus T2 values among the 3 groups (P > .05 for both). There was a significantly higher articular cartilage T2 value in the medial femorotibial articular cartilage for the MS group (P T2 value between the MS and MR groups (P > .05) in each articular cartilage plate. The medial tibial articular cartilage T2 value had a significant positive correlation with medial meniscus T2 value (r = 0.287; P = .024) CONCLUSION: This study demonstrates that knees with meniscectomy or meniscal repair had articular cartilage degeneration at 2 to 4 years postoperatively, with higher articular cartilage T2 relaxation time values compared with the knees with an intact meniscus. © 2015 The Author(s).

  20. Magnetic resonance imaging of anterior cruciate ligament of the knee: a comparison of four sequences; Valoracion del ligamento cruzado anterior de la rodilla con RM: comparacion de cuatro secuencias

    Energy Technology Data Exchange (ETDEWEB)

    Casillas, C.; Marti-Bonmati, L.; Molla, E.; Ferrer, P.; Dosda, R. [Clinical Quiron-ATQ. Valencia (Spain)

    1999-07-01

    To compare the diagnostic efficacy of the four magnetic resonance imaging (MRI) sequences that compose the standard protocol for the study of the knee in our center when employed in the examination of anterior cruciate ligament (ACL). A prospective study was carried out based on MRI findings in the knees of 326 consecutive patients. Sagittal [proton density (PD{sub w}eighted turbo-spin-echo and T2*-weighted gradient echo], coronal (PD-weighted turbo-spin-echo with fat suppression) and transverse (T2*-weighted gradient echo with magnetization transfer) images were evaluated. Each sequence was analyzed independently by two radiologists, while another two assessed all the sequences together with the clinical findings. Four categories were established: normal ACL, partially torn, completely torn and synovialized. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) with respect to the definitive diagnosis were calculated for each sequence. The statistical analysis of the findings for each category was done using the chi-squared test and the Kappa test was employed to assess the degree of agreement. According to the final diagnosis, 263 ACL were normal, 29 were partially torn, 33 were completely torn and there was 1 case of synovialization associated with a completely torn ACL. The relationship between the analysis of the ACL according to each sequence and the definitive diagnosis was very significant (p<0.001) and the agreement was excellent. All the sequences presented similar levels of diagnostic precision. The coronal sequence had least number of diagnostic errors (2.1%). The combinations of imaging techniques that resulted in the lowest error rate with respect to the definitive diagnosis were coronal PD-weighted turbo-spin-echo with fat suppression and sagittal PD-weighted turbo-spin-echo. Coronal images are highly precise in the evaluation of ACL. Sagittal sequences are the most valid for diagnosis of torn ACL

  1. Krill Oil Improves Mild Knee Joint Pain: A Randomized Control Trial.

    Directory of Open Access Journals (Sweden)

    Yoshio Suzuki

    Full Text Available Krill oil is an edible oil extracted from krill, a small red-colored crustacean found in the Antarctic Ocean. The administration of krill oil is reported to mitigate inflammation in patients with cardiac disease, rheumatoid arthritis, or osteoarthritis. However, the effect of krill oil on mild knee pain has not yet been determined.To assess the effect of krill oil on mild knee pain.A randomized, double-blind, parallel-group, placebo-controlled trial of fifty adults (38-85 years old with mild knee pain attending the Fukushima Orthopedic Clinic (Tochigi, Japan between September 2014 and March 2015.Participants were randomized to receive 2 g per day of either krill oil or an identical placebo for 30 days.The primary outcome was improvement in subjective symptoms of knee pain as assessed by the Japanese Knee Osteoarthritis Measure (JKOM and Japanese Orthopaedic Association score (JOA. Secondary outcomes included blood and urine biochemical parameters.Both the placebo and krill oil groups showed significant improvements in the questions in the JKOM and JOA questionnaires after administration. After the intervention, krill oil group showed more improvements than placebo group in two questions regarding the pain and stiffness in knees in JKOM. Controlling for age, sex, weight, and smoking and drinking habits, krill oil significantly mitigated knee pain in sleeping (P < 0.001, standing (P < 0.001 and the range of motion of both right and left knees (both P = 0.011 compared to placebo. Krill oil administration raised plasma EPA (P = 0.048 and EPA/AA ratio (P = 0.003.This study indicates that krill oil administration (2 g/day, 30 days improved the subjective symptoms of knee pain in adults with mild knee pain.UMIN-CTR; ID UMIN000014413.

  2. CURBSIDE CONSULTATION IN KNEE ARTHROPLASTY: 49 CLINICAL QUESTIONS

    Directory of Open Access Journals (Sweden)

    Craig J. Della Vale

    2008-12-01

    Full Text Available A user- friendly reference for decision making in complicated cases of knee arthroplasty desingned in a question and answers format composed of articles containing current concepts and preferences of experts in total knee replacement surgery, enhanced by several images, diagrams and references and written in the form of a casual advice by Craig J. Della Vale, MD. and his collaborators. PURPOSE By this practical reference of knee arthroplasty, the editor and the contributors have aimed providing straightforward and brief answers, evidence-based advices, their preference and opinions containing current concepts for unanswered questions about complicated cases in total knee replacement surgery which are often controversial and not addressed clearly in traditional knee arthroplasty references. FEATURES There are 49 subjects each written by a different expert designed in 4 sections in a question and answers format including several images and diagrams and also essential references at the end of each article. In the first section preoperative questions is subjected including indications, unicompartmental osteoarthritis of the knee, patient with vascular problems, donating blood, bilateral arthroplasty, patellar resurfacing, range of motion, bearing surface, contraindications, teaching class for patients prior surgery. The second section is about intraoperative questions including skin incision, patella femoral maltracking, femoral component rotation, tibial component rotation, lateral release, femoral component sizing, flexion instability, varus deformity, and valgus deformity, tightness in extension, iatrogenic MCL injury, antibiotic-loaded cement, and perioperative pain. The third section subjects postoperative questions including wound drainage, preventing tromboembolic events, vascular complications, foot drop, manipulation under anesthesia, patella fractures, supracondylar femur fractures, acute extensor mechanism disruptions. In the fourth

  3. SAGITTAL DIAMETER OF FORAMEN MAGNUM IN NORMAL POPULATION: AN MRI STUDY

    OpenAIRE

    Lakshmi

    2015-01-01

    Lower position of cerebellar tonsils was frequently noticed in Western studies. In some of the studies, sagittal diameter of foramen magnum was found to be larger in cases of Chiari malformation. However, there are no Indian studies for comparison. Our study was proposed to determine the standard values for sagittal diameter of foramen magnum in various age groups and both sexes. This gives a guideline for further studies in pathological conditions like Craniovertebral Junctional ...

  4. Knee Replacement

    Science.gov (United States)

    Knee replacement is surgery for people with severe knee damage. Knee replacement can relieve pain and allow you to ... Your doctor may recommend it if you have knee pain and medicine and other treatments are not ...

  5. Articular surface approximation in equivalent spatial parallel mechanism models of the human knee joint: an experiment-based assessment.

    Science.gov (United States)

    Ottoboni, A; Parenti-Castelli, V; Sancisi, N; Belvedere, C; Leardini, A

    2010-01-01

    In-depth comprehension of human joint function requires complex mathematical models, which are particularly necessary in applications of prosthesis design and surgical planning. Kinematic models of the knee joint, based on one-degree-of-freedom equivalent mechanisms, have been proposed to replicate the passive relative motion between the femur and tibia, i.e., the joint motion in virtually unloaded conditions. In the mechanisms analysed in the present work, some fibres within the anterior and posterior cruciate and medial collateral ligaments were taken as isometric during passive motion, and articulating surfaces as rigid. The shapes of these surfaces were described with increasing anatomical accuracy, i.e. from planar to spherical and general geometry, which consequently led to models with increasing complexity. Quantitative comparison of the results obtained from three models, featuring an increasingly accurate approximation of the articulating surfaces, was performed by using experimental measurements of joint motion and anatomical structure geometries of four lower-limb specimens. Corresponding computer simulations of joint motion were obtained from the different models. The results revealed a good replication of the original experimental motion by all models, although the simulations also showed that a limit exists beyond which description of the knee passive motion does not benefit considerably from further approximation of the articular surfaces.

  6. Knee Injuries

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Knee Injuries KidsHealth / For Teens / Knee Injuries What's in ... can do to protect them. What's in a Knee? The knee is a joint , actually the largest ...

  7. 'Lumbar Degenerative Kyphosis' Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception.

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-03-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal deformity. Unlike what its name suggests, LDK does not only include sagittal balance disorder of the lumbar spine and kyphosis, but also sagittal balance disorder of the whole spine and little lordosis of the lumbar spine. Moreover, this disease is closely related to the occupation of female farmers and an outdated Asian life style. These reasons necessitate a change in the nomenclature of this disorder to prevent misunderstanding. We suggest the name "primary degenerative sagittal imbalance" (PDSI), which encompasses degenerative sagittal misalignments of unknown origin in the whole spine in older-age patients, and is associated with back muscle wasting. LDK may be regarded as a subgroup of PDSI related to an occupation in agriculture. Conservative treatments such as exercise and physiotherapy are recommended as first-line treatments for patients with PDSI, and surgical treatment is considered only if conservative treatments failed. The measurement of spinopelvic parameters for sagittal balance is important prior to deformity corrective surgery. LDK can be considered a subtype of PDSI that is more likely to occur in female farmers, and hence the use of LDK as a global term for all degenerative sagittal imbalance disorders is better avoided. To avoid confusion, we recommend PDSI as a newer, more accurate diagnostic term instead of LDK.

  8. Radiographic assessment of knee-ankle alignment after total knee arthroplasty for varus and valgus knee osteoarthritis.

    Science.gov (United States)

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2017-01-01

    There are unanswered questions about knee-ankle alignment after total knee arthroplasty (TKA) for varus and valgus osteoarthritis (OA) of the knee. The aim of this retrospective study was to assess knee-ankle alignment after TKA. The study consisted of 149 patients who had undergone TKA due to varus and valgus knee OA. The alignment and angles in the selected knees and ankles were measured on full-length standing anteroposterior radiographs, both pre-operatively and post-operatively. The paired t-test and Pearson's correlation tests were used for statistical analysis. The results showed that ankle alignment correlated with knee alignment both pre-operatively and postoperatively (Pknee was corrected (Pknee-ankle alignment on the non-operative side (P>0.05). These findings indicated that routine TKA could correct the varus or valgus deformity of a knee, and improve the tilt of the ankle. Ankle alignment correlated with knee alignment both pre-operatively and postoperatively. Both pre-operative knee and ankle malalignment can be simultaneously corrected following TKA. Level III. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Clinically acceptable agreement between the ViMove wireless motion sensor system and the Vicon motion capture system when measuring lumbar region inclination motion in the sagittal and coronal planes

    DEFF Research Database (Denmark)

    Mjøsund, Hanne Leirbekk; Boyle, Eleanor; Kjær, Per

    2017-01-01

    . CONCLUSIONS: We found a clinically acceptable level of agreement between these two methods for measuring standing lumbar inclination motion in these two cardinal movement planes. Further research should investigate the ViMove system's ability to measure lumbar motion in more complex 3D functional movements...

  10. Biofeedback relaxation for pain associated with continuous passive motion in Taiwanese patients after total knee arthroplasty.

    Science.gov (United States)

    Wang, Tsae-Jyy; Chang, Ching-Fen; Lou, Meei-Fang; Ao, Man-Kuan; Liu, Chiung-Chen; Liang, Shu-Yuan; Wu, Shu-Fang Vivienne; Tung, Heng-Hsing

    2015-02-01

    Effective pain management is crucial for patient recovery after total knee arthroplasty (TKA). Biofeedback therapy, which encourages relaxation and helps alleviate various conditions associated with stress, may help to decrease postoperative pain in patients undergoing TKA. A quasi- experimental design was used to investigate the efficacy of a biofeedback relaxation intervention in reducing pain associated with postoperative continuous passive motion (CPM) therapy. Sixty-six patients admitted to a general hospital in Taiwan for TKA were recruited and randomly assigned to the intervention or control group. The intervention group received biofeedback training twice daily for 5 days, concurrent with CPM therapy, whereas the control group did not receive the biofeedback intervention. Pain was measured using a numeric rating scale before and after each CPM therapy session on postoperative days 1 through 5. The CPM-elicited pain score was calculated by subtracting the pre-CPM pain score from the post-CPM pain score. Results of repeated-measures analysis of variance showed intervention group reported significantly less pain caused by CPM than did the control group (f = 29.70, p biofeedback relaxation, a non-invasive and non-pharmacological intervention, as a complementary treatment option for pain management in this population. © 2014 Wiley Periodicals, Inc.

  11. Wide step width reduces knee abduction moment of obese adults during stair negotiation.

    Science.gov (United States)

    Yocum, Derek; Weinhandl, Joshua T; Fairbrother, Jeffrey T; Zhang, Songning

    2018-05-15

    An increased likelihood of developing obesity-related knee osteoarthritis may be associated with increased peak internal knee abduction moments (KAbM). Increases in step width (SW) may act to reduce this moment. The purpose of this study was to determine the effects of increased SW on knee biomechanics during stair negotiation of healthy-weight and obese participants. Participants (24: 10 obese and 14 healthy-weight) used stairs and walked over level ground while walking at their preferred speed in two different SW conditions - preferred and wide (200% preferred). A 2 × 2 (group × condition) mixed model analysis of variance was performed to analyze differences between groups and conditions (p < 0.05). Increased SW increased the loading-response peak knee extension moment during descent and level gait, decreased loading-response KAbMs, knee extension and abduction range of motion (ROM) during ascent, and knee adduction ROM during descent. Increased SW increased loading-response peak mediolateral ground reaction force (GRF), increased peak knee abduction angle during ascent, and decreased peak knee adduction angle during descent and level gait. Obese participants experienced disproportionate changes in loading-response mediolateral GRF, KAbM and peak adduction angle during level walking, and peak knee abduction angle and ROM during ascent. Increased SW successfully decreased loading-response peak KAbM. Implications of this finding are that increased SW may decrease medial compartment knee joint loading, decreasing pain and reducing joint deterioration. Increased SW influenced obese and healthy-weight participants differently and should be investigated further. Copyright © 2018. Published by Elsevier Ltd.

  12. Measuring Fractional Anisotropy of the Corpus Callosum Using Diffusion Tensor Imaging: Mid-Sagittal versus Axial Imaging Planes

    International Nuclear Information System (INIS)

    Kim, Eung Yeop; Park, Hae Jeong; Kim, Dong Hyun; Lee, Seung Koo; Kim, Jin Na

    2008-01-01

    Many diffusion tensor imaging (DTI) studies of the corpus callosum (CC) have been performed with a relatively thick slice thickness in the axial plane, which may result in underestimating the fractional anisotropy (FA) of the CC due to a partial volume effect. We hypothesized that the FA of the CC can be more accurately measured by using mid-sagittal DTI. We compared the FA values of the CC between the axial and mid-sagittal DTI. Fourteen healthy volunteers underwent MRI at 3.0 T. DTI was performed in both the mid-sagittal and axial planes. One 5-mm mid-sagittal image and twenty-five 2-mm axial images were obtained for the CC. The five regions of interest (ROIs) that included the prefrontal (I), premotor and supplementary motor (II), motor (III), sensory (IV) and parietal, temporal and occipital regions (V) were drawn along the border of the CC on each sagittal FA map. The FA values obtained from each region were compared between the two sagittal maps. The FA values of all the regions, except for region V, were significantly increased on the mid-sagittal imaging. The FA values in region IV were significantly underestimated on the mid-sagittal image from the axial imaging, compared with those in the regions I and V (p = 0.037 and p = 0.001, respectively). The FA values of the CC were significantly higher on the midsagittal DTI than those on the axial DTI in regions I-IV, and particularly in the region IV. Mid-sagittal DTI may provide more accurate FA values of the CC than can the axial DTI, and mid-sagittal DTI may be more desirable for studies that compare between patients and healthy subjects

  13. Self-reported previous knee injury and low knee function increase knee injury risk in adolescent female football.

    Science.gov (United States)

    Clausen, M B; Tang, L; Zebis, M K; Krustrup, P; Hölmich, P; Wedderkopp, N; Andersen, L L; Christensen, K B; Møller, M; Thorborg, K

    2016-08-01

    Knee injuries are common in adolescent female football. Self-reported previous knee injury and low Knee injury and Osteoarthritis Outcome Score (KOOS) are proposed to predict future knee injuries, but evidence regarding this in adolescent female football is scarce. The aim of this study was to investigate self-reported previous knee injury and low KOOS subscale score as risk factors for future knee injuries in adolescent female football. A sample of 326 adolescent female football players, aged 15-18, without knee injury at baseline, were included. Data on self-reported previous knee injury and KOOS questionnaires were collected at baseline. Time-loss knee injuries and football exposures were reported weekly by answers to standardized text-message questions, followed by injury telephone interviews. A priori, self-reported previous knee injury and low KOOS subscale scores (female football. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Relief of knee flexion contracture and gait improvement following adaptive training for an assist device in a transtibial amputee: A case study.

    Science.gov (United States)

    Kim, Sol-Bi; Ko, Chang-Yong; Son, Jinho; Kang, Sungjae; Ryu, Jeicheong; Mun, Museong

    2017-01-01

    Management of a knee contracture is important for regaining gait ability in transtibial amputees. However, there has been little study of prosthesis training for enhancing mobility and improving range of motion in cases of restricted knee extension. This study aimed to evaluate the effects of adaptive training for an assist device (ATAD) for a transtibial amputee with a knee flexion contracture (KFC). A male transtibial amputee with KFC performed 4 months of ATAD with a multidisciplinary team. During the ATAD, the passive range of motion (PROM) in the knee, amputee mobility predictor (AMP) assessment, center of pressure (COP) on a force plate-equipped treadmill, gait features determined by three-dimensional motion analysis, and Short-Form 36 Item Health Survey (SF-36) scores were evaluated. Following ATAD, PROM showed immediate improvement (135.6 ± 2.4° at baseline, 142.5 ± 1.7° at Step 1, 152.1 ± 1.8° at Step 2, 165.8 ± 1.9° at Step 3, and 166.0 ± 1.4° at Step 4); this was followed by an enhanced COP. Gradually, gait features also improved. Additionally, the AMP score (5 at baseline to 29 at Step 4) and K-level (K0 at baseline to K3 at Step 4) increased after ATAD. Along with these improvements, the SF-36 score also improved. ATAD could be beneficial for transtibial amputees by relieving knee contractures and improving gait.

  15. P.F.C Sigma® cruciate retaining fixed-bearing versus mobile-bearing knee arthroplasty: a prospective comparative study with minimum 10-year follow-up.

    Science.gov (United States)

    Riaz, O; Aqil, A; Sisodia, G; Chakrabarty, G

    2017-12-01

    To prospectively compare long-term clinical and radiological outcomes following a cruciate retaining fixed-bearing (FB) and a mobile-bearing (MB) primary total knee replacement (TKR). We prospectively reviewed 113 TKRs in 99 patients (14 bilateral) with a PFC sigma cruciate retaining rotating platform system, at an average follow-up of 11.1 years (range 10-12). Results were contrasted with those from 89 TKRs in 72 patients (17 bilateral) with a PFC sigma cruciate fixed-bearing prosthesis, at an average follow-up of 12.1 years (range 10-14.1). Outcomes collected included pre- and post-operative range of motion, Oxford Knee Scores, complications encountered, as well as radiographical assessments of polyethylene wear. In the MB group, mean Oxford Knee Scores improved from 16 pre-operatively to 42 at final follow-up. The mean range of motion was 115° (75-130). In the FB group, mean Oxford Knee Scores improved from 16.2 pre-operatively to 42.5 at final follow-up. The mean range of motion was 111.2 (80-135) degrees at final follow-up. We failed to elicit an objectively demonstrable clinical difference between the MB- and FB-implanted knees. Similarly, radiological benefits of the MB implants with regard to polyethylene wear were not evident at a minimum 10-year follow-up.

  16. Sagittal Alignment As a Predictor of Clinical Adjacent Segment Pathology requiring Surgery after Anterior Cervical Arthrodesis

    Science.gov (United States)

    Park, Moon Soo; Kelly, Michael P.; Lee, Dong-Ho; Min, Woo-Kie; Rahman, Ra’Kerry K.; Riew, K. Daniel

    2014-01-01

    BACKGROUND CONTEXT Postoperative malalignment of the cervical spine may alter cervical spine mechanics, and put patients at risk for clinical adjacent segment pathology requiring surgery. PURPOSE To investigate whether a relationship exists between cervical spine sagittal alignment and clinical adjacent segment pathology requiring surgery (CASP-S) following anterior cervical fusion (ACF). STUDY DESIGN Retrospective matched study. PATIENT SAMPLE One hundred twenty two patients undergoing ACF from 1996 to 2008 were identified, with a minimum of 2 year follow-up. OUTCOME MEASURES Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior endplate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. METHODS One hundred twenty two patients undergoing ACF from 1996 to 2008 were identified, with a minimum of 1 year follow-up. Patients were divided into groups according to the development of CASP requiring surgery (Control / CASP-S) and by number/location of levels fused. Radiographs were reviewed to measure the sagittal alignment using C2 and C7 sagittal plumb lines, distance from the fusion mass plumb line to the C2 and C7 plumb lines, the alignment of the fusion mass, caudally adjacent disc angle, the sagittal slope angle of the superior endplate of the vertebra caudally adjacent to the fusion mass, T1 sagittal angle, overall cervical sagittal alignment, and curve patterns by Katsuura classification. Appropriate statistical tests were performed to calculate relationships between the variables and the development of CASP-S. No funds were received in support of this work. No benefits in any form have been or will be received from a commercial party related

  17. Pericruciate fat pad of the knee: anatomy and pericruciate fat pad inflammation: cadaveric and clinical study emphasizing MR imaging

    International Nuclear Information System (INIS)

    Skaf, Abdalla Youssef; Hernandez Filho, Guinel; Dirim, Berna; Wangwinyuvirat, Mani; Trudell, Debra; Resnick, Donald; Haghigi, Parvitz

    2012-01-01

    The pericruciate fat pad is located in the intercondylar fossa, intimate with the cruciate ligaments. With MR imaging, signal abnormality of the pericruciate fat pad has been observed in patients with posterior knee pain. The purpose of this study was to describe the anatomy of the pericruciate fat pad in cadaveric specimens and to document the clinical spectrum of pericruciate fat pad inflammation. Twelve cadaveric knees underwent MR imaging with T1 and T2 multiplanar images. Cadaveric sections were then prepared for macroscopic evaluation, with additional histologic analysis performed in four cases. MR images in seventeen patients (ten males, seven females; average age, 31.5 years; age range, 19-57 years) involved in intensive sporting activity and with posterior knee pain were reviewed. MR images in cadaveric specimens showed a fat pad that was located above and between the cruciate ligaments, near their attachment sites in the inner portion of the femoral condyles, within the intercondylar fossa. Fatty tissue covered by a thin layer of synovial membrane was confirmed at histology. Seventeen patients with posterior knee pain and without gross cartilage, meniscal, or ligamentous abnormalities all revealed an increased signal in this fat pad in fluid-sensitive fat-suppressed images, mainly in the sagittal and axial planes. In eight cases, enhancement of this fat pad was demonstrated following intravenous gadolinium administration. The pericruciate fat pad is a structure located in the intercondylar fossa, intimate with both the anterior and posterior cruciate ligaments. Inflammatory changes in this fat pad may be found in patients, especially athletes with posterior knee pain. (orig.)

  18. Pericruciate fat pad of the knee: anatomy and pericruciate fat pad inflammation: cadaveric and clinical study emphasizing MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Skaf, Abdalla Youssef [Hospital do Coracao (HCor), Department of Radiology, Sao Paulo, SP (Brazil); Hernandez Filho, Guinel [Santa Casa de Sao Paulo Hospital, Department of Radiology, Sao Paulo, SP (Brazil); Dirim, Berna [Izmir Atatuerk Training and Research Hospital, Department of Radiology, Karsiyaka, izmir (Turkey); Wangwinyuvirat, Mani [Rajavithi Hospital, Department of Radiology, Bangkok (Thailand); Trudell, Debra; Resnick, Donald [University of California, San Diego, Department of Radiology, Veterans Affairs Medical Center, La Jolla, CA (United States); Haghigi, Parvitz [University of California, San Diego, Department of Pathology, Veterans Affairs Medical Center, La Jolla, CA (United States)

    2012-12-15

    The pericruciate fat pad is located in the intercondylar fossa, intimate with the cruciate ligaments. With MR imaging, signal abnormality of the pericruciate fat pad has been observed in patients with posterior knee pain. The purpose of this study was to describe the anatomy of the pericruciate fat pad in cadaveric specimens and to document the clinical spectrum of pericruciate fat pad inflammation. Twelve cadaveric knees underwent MR imaging with T1 and T2 multiplanar images. Cadaveric sections were then prepared for macroscopic evaluation, with additional histologic analysis performed in four cases. MR images in seventeen patients (ten males, seven females; average age, 31.5 years; age range, 19-57 years) involved in intensive sporting activity and with posterior knee pain were reviewed. MR images in cadaveric specimens showed a fat pad that was located above and between the cruciate ligaments, near their attachment sites in the inner portion of the femoral condyles, within the intercondylar fossa. Fatty tissue covered by a thin layer of synovial membrane was confirmed at histology. Seventeen patients with posterior knee pain and without gross cartilage, meniscal, or ligamentous abnormalities all revealed an increased signal in this fat pad in fluid-sensitive fat-suppressed images, mainly in the sagittal and axial planes. In eight cases, enhancement of this fat pad was demonstrated following intravenous gadolinium administration. The pericruciate fat pad is a structure located in the intercondylar fossa, intimate with both the anterior and posterior cruciate ligaments. Inflammatory changes in this fat pad may be found in patients, especially athletes with posterior knee pain. (orig.)

  19. Comparison of accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions: An exvivo study

    Directory of Open Access Journals (Sweden)

    Asieh Zamani Naser

    2010-01-01

    Full Text Available Background: Radiographic examination of TMJ is indicated when there are clinical signs of pathological conditions, mainly bone changes that may influence the diagnosis and treatment planning. The purpose of this study was to evaluate and to compare the validity and diagnostic accuracy of uncorrected and corrected sagittal tomographic images in the detection of simulated mandibular condyle erosions. Methods : Simulated lesions were created in 10 dry mandibles using a dental round bur. Using uncorrected and corrected sagittal tomography techniques, mandibular condyles were imaged by a Cranex Tome X-ray unit before and after creating the lesions. The uncorrected and corrected tomography images were examined by two independent observers for absence or presence of a lesion. The accuracy for detecting mandibular condyle lesions was expressed as sensitivity, specificity, and validity values. Differences between the two radiographic modalities were tested by Wilcoxon for paired data tests. Inter-observer agreement was determined by Cohen′s Kappa. Results: The sensitivity, specificity and validity were 45%, 85% and 30% in uncorrected sagittal tomographic images, respectively, and 70%, 92.5% and 60% in corrected sagittal tomographic images, respectively. There was a significant statistical difference between the accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions (P = 0.016. The inter-observer agreement was slight for uncorrected sagittal tomography and moderate for corrected sagittal tomography. Conclusion: The accuracy of corrected sagittal tomography is significantly higher than that of uncorrected sagittal tomography. Therefore, corrected sagittal tomography seems to be a better modality in detection of mandibular condyle erosions.

  20. Knee and Hip Joint Kinematics Predict Quadriceps and Hamstrings Neuromuscular Activation Patterns in Drop Jump Landings.

    Science.gov (United States)

    Malfait, Bart; Dingenen, Bart; Smeets, Annemie; Staes, Filip; Pataky, Todd; Robinson, Mark A; Vanrenterghem, Jos; Verschueren, Sabine

    2016-01-01

    The purpose was to assess if variation in sagittal plane landing kinematics is associated with variation in neuromuscular activation patterns of the quadriceps-hamstrings muscle groups during drop vertical jumps (DVJ). Fifty female athletes performed three DVJ. The relationship between peak knee and hip flexion angles and the amplitude of four EMG vectors was investigated with trajectory-level canonical correlation analyses over the entire time period of the landing phase. EMG vectors consisted of the {vastus medialis(VM),vastus lateralis(VL)}, {vastus medialis(VM),hamstring medialis(HM)}, {hamstring medialis(HM),hamstring lateralis(HL)} and the {vastus lateralis(VL),hamstring lateralis(HL)}. To estimate the contribution of each individual muscle, linear regressions were also conducted using one-dimensional statistical parametric mapping. The peak knee flexion angle was significantly positively associated with the amplitudes of the {VM,HM} and {HM,HL} during the preparatory and initial contact phase and with the {VL,HL} vector during the peak loading phase (phamstrings medialis activity) during the preparatory and initial contact phase and an increased lateral neuromuscular activation (dominant vastus lateralis activity) during the peak loading phase.

  1. Direct CT scanning of the lesser pelvis - frontal vs sagittal plane

    International Nuclear Information System (INIS)

    Khadzhigeorgiev, G.; Lichev, A.

    1994-01-01

    Whenever axial scanning alone is used, the anatomical patterns of the true pelvis and the organs contained in it, particularly in women, give rise to diagnostic difficulties during CT assessment of neoplasms originating from these organs. The high demands on precision characterization of the pathological changes in the pelvis minor organs necessitate the obtaining of reliable density and size measurement data, not merely from the axial plane, but from the frontal and sagittal ones as well. The deficient information afforded by secondary reconstruction of the pelvis mind images requires an mandatory evaluation of the potentialities of direct frontal and direct sagittal scanning of the pelvis minor using standard CT equipment. Information yielded by images from direct frontal and direct sagittal pelvis minor scanning as well as diagnostic problems where application of this type of scanning is indicated operational difficulties and their overcoming, are among the issues discussed. 8 figs., 7 refs

  2. A comparison of cephalometric analyses for assessing sagittal jaw relationship

    International Nuclear Information System (INIS)

    Erum, G.; Fida, M.

    2008-01-01

    To compare the seven methods of cephalometric analysis for assessing sagittal jaw relationship and to determine the level of agreement between them. Seven methods, describing anteroposterior jaw relationships (A-B plane, ANB, Wits, AXB, AF-BF, FABA and Beta angle) were measured on the lateral cephalographs of 85 patients. Correlation analysis, using Cramer's V-test, was performed to determine the possible agreement between the pair of analyses. The mean age of the sample, comprising 35 males and 50 females was 15 years and 3 months. Statistically significant relationships were found among seven sagittal parameters with p-value <0.001. Very strong correlation was found between AXB and AF-BF distance (r=0.924); and weak correlation between ANB and Beta angle (r=0.377). Wits appraisal showed the greatest coefficient of variability. Despite varying strengths of association, statistically significant correlations were found among seven methods for assessing sagittal jaw relationship. FABA and A-B plane may be used to predict the skeletal class in addition to the established ANB angle. (author)

  3. PARAMETERS FOR THE EVALUATION OF CERVICAL SAGITTAL BALANCE IN IDIOPATHIC SCOLIOSIS

    Directory of Open Access Journals (Sweden)

    MAURICIO COELHO LIMA

    Full Text Available ABSTRACT Objective: There are no values defined as standard in the literature for the parameters of assessment of cervical sagittal balance in patients with idiopathic scoliosis. This study describes the sagittal cervical parameters in patients with idiopathic scoliosis. Methods: Study carried out in a tertiary public hospital in patients with adolescent idiopathic scoliosis, through the evaluation of panoramic radiographs in lateral view. The Cobb method was used to evaluate cervical lordosis from C2 to C7, distance from the center of gravity (COG of the skull to C7, measurement of T1 slope, thoracic inlet angle (TIA, neck tilt, and plumb line from C7 to S1 (SVA C7-S1. A statistical analysis was performed, to demonstrate the relationship between the alignment of the thoracic spine in the sagittal plane and the cervical sagittal balance of patients with scoliosis. Results: Thirty-four patients were female (69.4% and 15 male (30.6%. The mean values for COG-C7 were 0.71 mm (median 0.8 mm/standard deviation [SD]= 0.51 mm. For Cobb C2-C7, the mean was -11.7° (median -10°/SD= 20.4°. The mean slope of T1 was 23.5° (median 25°/SD= 9.5°. The mean cervical version was 58.8° (median 60°/DP= 15.4°. The mean TIA was 81.8° (median 85°/SD= 16.7°. The mean plumb line C7-S1 was -0.28 (-0.3/SD= 1.0. Conclusion: The analysis of the results showed that the mean values for the cervical lordosis are lower than the values described as normal in the literature, suggesting a loss of sagittal cervical balance in these patients.

  4. Modelling and Simulation of the Knee Joint with a Depth Sensor Camera for Prosthetics and Movement Rehabilitation

    Science.gov (United States)

    Risto, S.; Kallergi, M.

    2015-09-01

    The purpose of this project was to model and simulate the knee joint. A computer model of the knee joint was first created, which was controlled by Microsoft's Kinect for Windows. Kinect created a depth map of the knee and lower leg motion independent of lighting conditions through an infrared sensor. A combination of open source software such as Blender, Python, Kinect SDK and NI_Mate were implemented for the creation and control of the simulated knee based on movements of a live physical model. A physical size model of the knee and lower leg was also created, the movement of which was controlled remotely by the computer model and Kinect. The real time communication of the model and the robotic knee was achieved through programming in Python and Arduino language. The result of this study showed that Kinect in the modelling of human kinematics and can play a significant role in the development of prosthetics and other assistive technologies.

  5. Modelling and Simulation of the Knee Joint with a Depth Sensor Camera for Prosthetics and Movement Rehabilitation

    International Nuclear Information System (INIS)

    Risto, S; Kallergi, M

    2015-01-01

    The purpose of this project was to model and simulate the knee joint. A computer model of the knee joint was first created, which was controlled by Microsoft's Kinect for Windows. Kinect created a depth map of the knee and lower leg motion independent of lighting conditions through an infrared sensor. A combination of open source software such as Blender, Python, Kinect SDK and NI-Mate were implemented for the creation and control of the simulated knee based on movements of a live physical model. A physical size model of the knee and lower leg was also created, the movement of which was controlled remotely by the computer model and Kinect. The real time communication of the model and the robotic knee was achieved through programming in Python and Arduino language. The result of this study showed that Kinect in the modelling of human kinematics and can play a significant role in the development of prosthetics and other assistive technologies. (paper)

  6. Extrinsic Factors as Component Positions to Bone and Intrinsic Factors Affecting Postoperative Rotational Limb Alignment in Total Knee Arthroplasty.

    Science.gov (United States)

    Mochizuki, Tomoharu; Sato, Takashi; Tanifuji, Osamu; Watanabe, Satoshi; Kobayashi, Koichi; Endo, Naoto

    2018-02-13

    This study aimed to identify the factors affecting postoperative rotational limb alignment of the tibia relative to the femur. We hypothesized that not only component positions but also several intrinsic factors were associated with postoperative rotational limb alignment. This study included 99 knees (90 women and 9 men) with a mean age of 77 ± 6 years. A three-dimensional (3D) assessment system was applied under weight-bearing conditions to biplanar long-leg radiographs using 3D-to-2D image registration technique. The evaluation parameters were (1) component position; (2) preoperative and postoperative coronal, sagittal, and rotational limb alignment; (3) preoperative bony deformity, including femoral torsion, condylar twist angle, and tibial torsion; and (4) preoperative and postoperative range of motion (ROM). In multiple linear regression analysis using a stepwise procedure, postoperative rotational limb alignment was associated with the following: (1) rotation of the component position (tibia: β = 0.371, P intrinsic factors, such as preoperative rotational limb alignment, ROM, and tibial torsion, affected postoperative rotational limb alignment. On a premise of correct component positions, the intrinsic factors that can be controlled by surgeons should be taken care. In particular, ROM is necessary to be improved within the possible range to acquire better postoperative rotational limb alignment. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Influence of knee flexion and atraumatic mobilisation of infrapatellar fat pad on incidence and severity of anterior knee pain after tibial nailing.

    Science.gov (United States)

    Jankovic, Andrija; Korac, Zelimir; Bozic, Nenad-Bozo; Stedul, Ivan

    2013-09-01

    We evaluated the incidence and aetiology of anterior knee pain (AKP) in a series of patients that underwent intramedullary nailing for stabilisation of tibial fractures. During the preparation of the entry site no excision of the infrapatellar fat was allowed and electrical haemostasis was kept at the lowest level. Medullary canal was reamed and the nails inserted in position of knee flexion over 100 degrees. All fractures were fixed using medial paratendinous approach. Functional outcome was measured using Lysholm knee score. The knee range of movement and return to previous level of activity were also documented and analysed. Mean follow up was 38.9 months (range 12-84 months). In total 60 patients with 62 tibial shaft fractures were analysed. The mean age at the time of final follow up was 49.4 years (range 20-87). In 22 (35.5%) a newly developed and persisting pain in the anterior region of the operated knee was reported. According to VAP scale, the pain was mild (VAS 1-3) in 12 cases (19.4%) and moderate (VAS 4-6) in 10 (16.1%). In 16 cases (73%) the pain was noticed 6-12 months after injury and subjectively related to return to full range of working and recreational activities. The mean Lysholm knee score in the group without AKP was 90.8. In the AKP group with mild pain it was 88.4 and in the group with moderate AKP it was 79.9. Complete return to previous professional and recreational activities occurred in 49/60 patients (81.7%). Content with the treatment regarding expectations in recovery dynamics and return to desired level of activity was present in 98.3% of patients; one patient was unsatisfied with the treatment. Our results indicate that respecting the physiological motion of Hoffa pad and menisci during knee flexion, accompanied with atraumatic mobilisation of retrotendinous fat, reduces incidence and severity of anterior knee pain following intramedullary fixation of tibial shaft fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Sagittal plane analysis of the spine and pelvis in degenerative lumbar scoliosis.

    Science.gov (United States)

    Han, Fei; Weishi, Li; Zhuoran, Sun; Qingwei, Ma; Zhongqiang, Chen

    2017-01-01

    Previous studies have reported the normative values of pelvic sagittal parameters, but no study has analyzed the sagittal spino-pelvic alignment in degenerative lumbar scoliosis (DLS) and its role in the pathogenesis. Retrospective analysis was applied to 104 patients with DLS, together with 100 cases of asymptomatic young adults as a control group and another control group consisting of 145 cases with cervical spondylosis. The coronal and sagittal parameters were measured on the anteroposterior and lateral radiograph of the whole spine in the DLS group as well as in the two control groups. Statistical analysis showed that the DLS group had a higher pelvic incidence (PI) value (50.5° ± 10.2°), than the normal control group (with PI 47.2° ± 8.8°) and the cervical spondylosis group (46.9° ± 9.1°). In DLS group, there were 38 cases (36.5%) complicated with degenerative lumbar spondylolisthesis, who had higher PI values than patients without it. Besides, the lumbar lordosis (LL) and sacral slope (SS) of DLS group were lower; the scoliosis Cobb's angle was correlated with pelvic tilt (PT); thoracic kyphosis was correlated with LL, SS, and PT; and LL was correlated with other sagittal parameters. Patients with DLS may have a higher PI, which may impact the pathogenesis of DLS. A high PI value is probably associated with the high prevalence of degenerative lumbar spondylolisthesis among DLS patients. In DLS patients, the lumbar spine maintains the ability of regulating the sagittal balance, and the regulation depends more on thoracic curve.

  9. An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data.

    Science.gov (United States)

    Breen, Alan C; Muggleton, Jennifer M; Mellor, Fiona E

    2006-01-04

    Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing. Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptomatic volunteers. Calibration model 1 (mobile) was screened upright, in 7 inter-vertebral positions. The volunteers and calibration model 2 (fixed) were screened on a motorized table comprising 2 horizontal sections, one of which moved through 80 degrees. Model 2 was screened during motion 5 times and the L2-S1 levels of the volunteers twice. Images were digitised at 5fps. Inter-vertebral motion from model 1 was compared to its pre-settings to investigate accuracy. For volunteers and model 2, the first digitised image in each sequence was marked with templates. Vertebrae were tracked throughout the motion using automated frame-to-frame registration. For each frame, vertebral angles were subtracted giving inter-vertebral motion graphs. Volunteer data were acquired twice on the same day and analysed by two blinded observers. The root-mean-square (RMS) differences between paired data were used as the measure of reliability. RMS difference between reference and computed inter-vertebral angles in model 1 was 0.32 degrees for side-bending and 0.52 degrees for flexion-extension. For model 2, X-ray positioning contributed more to the variance of range measurement than did automated registration. For volunteer image sequences, RMS inter-observer variation in intervertebral motion range in the coronal plane was 1.86 degrees and intra-subject biological variation was between 2.75 degrees and 2.91 degrees. RMS inter-observer variation in the sagittal plane was 1.94 degrees. Radiation dosages in each view were below

  10. Medio-lateral knee fluency in anterior cruciate ligament-injured athletes during dynamic movement trials.

    Science.gov (United States)

    Panos, Joseph A; Hoffman, Joshua T; Wordeman, Samuel C; Hewett, Timothy E

    2016-03-01

    Correction of neuromuscular impairments after anterior cruciate ligament injury is vital to successful return to sport. Frontal plane knee control during landing is a common measure of lower-extremity neuromuscular control and asymmetries in neuromuscular control of the knee can predispose injured athletes to additional injury and associated morbidities. Therefore, this study investigated the effects of anterior cruciate ligament injury on knee biomechanics during landing. Two-dimensional frontal plane video of single leg drop, cross over drop, and drop vertical jump dynamic movement trials was analyzed for twenty injured and reconstructed athletes. The position of the knee joint center was tracked in ImageJ software for 500 milliseconds after landing to calculate medio-lateral knee motion velocities and determine normal fluency, the number of times per second knee velocity changed direction. The inverse of this calculation, analytical fluency, was used to associate larger numerical values with fluent movement. Analytical fluency was decreased in involved limbs for single leg drop trials (P=0.0018). Importantly, analytical fluency for single leg drop differed compared to cross over drop trials for involved (Pinjury. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. A Combined Experimental and Computational Approach to Subject-Specific Analysis of Knee Joint Laxity

    Science.gov (United States)

    Harris, Michael D.; Cyr, Adam J.; Ali, Azhar A.; Fitzpatrick, Clare K.; Rullkoetter, Paul J.; Maletsky, Lorin P.; Shelburne, Kevin B.

    2016-01-01

    Modeling complex knee biomechanics is a continual challenge, which has resulted in many models of varying levels of quality, complexity, and validation. Beyond modeling healthy knees, accurately mimicking pathologic knee mechanics, such as after cruciate rupture or meniscectomy, is difficult. Experimental tests of knee laxity can provide important information about ligament engagement and overall contributions to knee stability for development of subject-specific models to accurately simulate knee motion and loading. Our objective was to provide combined experimental tests and finite-element (FE) models of natural knee laxity that are subject-specific, have one-to-one experiment to model calibration, simulate ligament engagement in agreement with literature, and are adaptable for a variety of biomechanical investigations (e.g., cartilage contact, ligament strain, in vivo kinematics). Calibration involved perturbing ligament stiffness, initial ligament strain, and attachment location until model-predicted kinematics and ligament engagement matched experimental reports. Errors between model-predicted and experimental kinematics averaged ligaments agreed with literature descriptions. These results demonstrate the ability of our constraint models to be customized for multiple individuals and simultaneously call attention to the need to verify that ligament engagement is in good general agreement with literature. To facilitate further investigations of subject-specific or population based knee joint biomechanics, data collected during the experimental and modeling phases of this study are available for download by the research community. PMID:27306137

  12. Influence of implant rod curvature on sagittal correction of scoliosis deformity

    DEFF Research Database (Denmark)

    Salmingo, Remel A.; Tadano, Shigeru; Abe, Yuichiro

    2014-01-01

    of the implant rod’s angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. STUDY DESIGN: A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. PATIENT SAMPLE: Twenty adolescent idiopathic......BACKGROUND CONTEXT: Deformation of in vivo–implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. PURPOSE: To analyze the changes...... scoliosis patients underwent surgery. Average age at the time of operation was 14 years. OUTCOME MEASURES: The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. METHODS: Two implant rods were attached to the concave and convex side...

  13. Provocative mechanical tests of the peripheral nervous system affect the joint torque-angle during passive knee motion.

    Science.gov (United States)

    Andrade, R J; Freitas, S R; Vaz, J R; Bruno, P M; Pezarat-Correia, P

    2015-06-01

    This study aimed to determine the influence of the head, upper trunk, and foot position on the passive knee extension (PKE) torque-angle response. PKE tests were performed in 10 healthy subjects using an isokinetic dynamometer at 2°/s. Subjects lay in the supine position with their hips flexed to 90°. The knee angle, passive torque, surface electromyography (EMG) of the semitendinosus and quadriceps vastus medialis, and stretch discomfort were recorded in six body positions during PKE. The different maximal active positions of the cervical spine (neutral; flexion; extension), thoracic spine (neutral; flexion), and ankle (neutral; dorsiflexion) were passively combined for the tests. Visual analog scale scores and EMG were unaffected by body segment positioning. An effect of the ankle joint was verified on the peak torque and knee maximum angle when the ankle was in the dorsiflexion position (P torque (P torque when the cervical and thoracic spines were flexed (P torque-angle response since different positions of head, upper trunk, and foot induce dissimilar knee mechanical responses during passive extension. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Passive Back Support Exoskeleton Improves Range of Motion Using Flexible Beams

    Directory of Open Access Journals (Sweden)

    Matthias B. Näf

    2018-06-01

    Full Text Available In the EU, lower back pain affects more than 40% of the working population. Mechanical loading of the lower back has been shown to be an important risk factor. Peak mechanical load can be reduced by ergonomic interventions, the use of cranes and, more recently, by the use of exoskeletons. Despite recent advances in the development of exoskeletons for industrial applications, they are not widely adopted by industry yet. Some of the challenges, which have to be overcome are a reduced range of motion, misalignment between the human anatomy and kinematics of the exoskeleton as well as discomfort. A body of research exists on how an exoskeleton can be designed to compensate for misalignment and thereby improve comfort. However, how to design an exoskeleton that achieves a similar range of motion as a human lumbar spine of up to 60° in the sagittal plane, has not been extensively investigated. We addressed this need by developing and testing a novel passive back support exoskeleton, including a mechanism comprised of flexible beams, which run in parallel to the spine, providing a large range of motion and lowering the peak torque requirements around the lumbo-sacral (L5/S1 joint. Furthermore, we ran a pilot study to test the biomechanical (N = 2 and functional (N = 3 impact on subjects while wearing the exoskeleton. The biomechanical testing was once performed with flexible beams as a back interface and once with a rigid structure. An increase of more than 25% range of motion of the trunk in the sagittal plane was observed by using the flexible beams. The pilot functional tests, which are compared to results from a previous study with the Laevo device, suggest, that the novel exoskeleton is perceived as less hindering in almost all tested tasks.

  15. Mid- term results of stryker® scorpio plus mobile bearing total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Kobayashi Hideo

    2012-10-01

    Full Text Available Abstract Background The mobile bearing knee system was introduced to lessen contact stress on the articular bearing surface and reduce polyethylene wear. The purpose of the current study was to investigate the mid-term results of patients undergoing total knee arthroplasties (TKAs using Scorpio Plus Mobile Bearing Knee System (Stryker, Mahwah, NJ, and compare the outcomes between patients with osteoarthritis and osteonecrosis (OA·ON group and patients with rheumatoid arthritis (RA group. Methods Eight males and 58 females were followed up for a period of 4.4- 7.6 years from June 1, 2003 to December 31, 2005. There were 53 knees with osteoarthritis, 17 knees with rheumatoid arthritis, and 6 knees with osteonecrosis. Clinical and radiographic follow- up was done using The Japanese Orthopedic Association knee rating score (JOA score and Knee Society Total Knee Arthroplasty Roentgenographic Evaluation and Scoring System. Results With regard to the JOA score, there was significant improvement in both groups. The postoperative range of motion was between 0.8°and 116.8° in OA·ON group, and between 0.0° and 113.7° in RA group. There were no significant differences with the radiographic evaluation between two groups. Spontaneous dislocation of a polyethylene insert occurred in one patient, and deep infection was occurred in one patient. Conclusion There was significant improvement with regard to the clinical and radiographic results of patients undergoing TKAs using the model. The risk of polyethylene insert dislocation related to the mobile bearing TKA is a cause for concern.

  16. Arthroscopic treatment of patients with moderate arthrofibrosis after total knee replacement.

    Science.gov (United States)

    Jerosch, Joerg; Aldawoudy, Akram M

    2007-01-01

    The purpose of this study was to document the effect of arthroscopic management in patients with knee stiffness after total knee replacement. We present a case series study, in which 32 patients have been treated for moderate arthrofibrosis of the knee after total knee replacement, with the same regimen. We have excluded all cases of stiffness, because of infection, mechanical mal-alignment, loosening of the implants and other obvious reasons of stiffness of the knee, rather than pure arthrofibrosis. All patients first underwent a trial of conservative treatment before going for arthroscopic management. A pain catheter for femoral nerve block was inserted just before anesthesia for post-operative pain management. Arthroscopic arthrolysis of the intra-articular pathology was performed in a standardized technique with release of all fibrous bands in the suprapatellar pouch, reestablishing the medial and lateral gutter, release of the patella, resection of the remaining meniscal tissue or an anterior cyclops, if needed. Intensive physiotherapy and continuous passive motion were to start immediately post-operatively. All the patients were available for the follow up and they were evaluated using the knee society rating system. A total of 25 of the 32 procedures resulted in an improvement of the patients knee score. All the knees operated upon had intra-articular fibrous bands, hypertrophic synovitis and peri-patellar adhesions. A total of eight patients suffered from an anterior cyclops lesion and six patients showed pseudomenicus. In 19 cases a medial and lateral relapse of the patella was performed; only 5 patients got an isolated lateral release. The mean knee flexion was 119 degrees (100-130) at the end of arthroscopy and was 97 degrees (75-115) at the last follow up. The eight patients with extension lags decreased from 27 degrees (10 degrees-35 degrees) pre-operatively to 4 degrees (0-10) at time of follow up. The average knee society ratings increased from 70

  17. Knee Control and Jump-Landing Technique in Young Basketball and Floorball Players.

    Science.gov (United States)

    Leppänen, M; Pasanen, K; Kulmala, J-P; Kujala, U M; Krosshaug, T; Kannus, P; Perttunen, J; Vasankari, T; Parkkari, J

    2016-04-01

    Poor knee alignment is associated with increased loading of the joints, ligaments and tendons, and may increase the risk of injury. The study purpose was to compare differences in knee kinematics between basketball and floorball players during a vertical drop jump (VDJ) task. We wanted to investigate whether basketball players, whose sport includes frequent jump-landings, exhibited better knee control compared with floorball players, whose sport involves less jumping. Complete data was obtained from 173 basketball and 141 floorball players. Peak knee valgus and flexion angles during the VDJ were analyzed by 3D motion analysis.Larger knee valgus angles were observed among basketball players (- 3.2°, 95%CI -4.5 to - 2.0) compared with floorball players (- 0.9°, 95%CI -2.3 to 0.6) (P=0.022). Basketball players landed with a decreased peak knee flexion angle (83.1°, 95%CI 81.4 to 84.8) compared with floorball players (86.5°, 95%CI 84.6 to 88.4) (P=0.016). There were no significant differences in height, weight or BMI between basketball and floorball players. Female athletes exhibited significantly greater valgus angles than males. This study revealed that proper knee control during jump-landing does not seem to develop in young athletes simply by playing the sport, despite the fact that jump-landings occur frequently in practice and games. © Georg Thieme Verlag KG Stuttgart · New York.

  18. The longitudinal sagittal growth changes of maxilla and mandible according to quantitative cervical vertebral maturation.

    Science.gov (United States)

    Chen, Lili; Lin, Jiuxiang; Xu, Tianmin; Long, Xiaosi

    2009-04-01

    To investigate the longitudinal sagittal growth changes of maxilla and mandible according to the quantitative cervical vertebral maturation (QCVM) for adolescents with normal occlusion, mixed longitudinal data were used. The samples included 87 adolescents aged from 8 to 18 y old with normal occlusion (32 males, 55 females) selected from 901 candidates. Sequential lateral cephalograms and hand-wrist films were taken once a year, lasting for 6 y. The longitudinal sagittal growth changes of maxilla and mandible according to QCVM were measured. There were some significant differences between maxilla and mandible according to QCVM. The sagittal growth change of maxilla showed a trend towards high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. The sagittal growth change of mandible showed a trend towards accelerating velocity-->high velocity-->decelerating velocity-->completing velocity from QCVM stage I to stage IV. With sagittal relationship, growth magnitude was almost the same between maxilla and mandible at QCVM stage I. At stage II the growth of mandible exceeded that of maxilla and growth in mandible continued at stages III and IV, while the maxilla ceased to grow. Growth magnitude was greater and the growth duration was longer with male mandible. It is concluded that the longitudinal sagittal growth changes of maxilla and mandible on the basis of QCVM is of value in the orthodontic practice.

  19. EFFECTIVENESS OF PNF STRETCHING VERSUS STATIC STRETCHING ON PAIN AND HAMSTRING FLEXIBILITY FOLLOWING MOIST HEAT IN INDIVIDUALS WITH KNEE OSTEOARTHRITIS

    Directory of Open Access Journals (Sweden)

    Meena .V

    2016-10-01

    Full Text Available Background: Osteoarthritis (OA is a degenerative joint disease and one of the major public health problem that causesfunctional impairment and reduced quality of life. To compare the effectiveness of PNF Hold relax stretching versus Static stretching on pain and flexibility of hamstring following moist heat in individuals with knee osteoarthritis. Hamstring tightness is the major problem in knee osteoarthritis individuals. Therefore the need of study is comparing the effectiveness of PNF Hold relax stretching versus static stretching on pain and flexibility of hamstrings following moist heat in knee osteoarthritis participants. Determining the effects of PNF Hold relax stretching versus Static stretching along with moist heat on pain and hamstring flexibility by VAS and Active knee extension range of motion in knee osteoarthritis individuals. Methods: 30 subjects with symptoms of knee osteoarthritis were randomly distributed into 2 groups 15 in each group. PNF Hold relax stretching along with moist heat is compared to Static stretching along with moist heat. Pain was measured by Visual Analogue Scale (VAS and hamstring flexibility by Active knee Extension Range of Motion (AKEROM by universal goniometer. Measurements are taken pre and post intervention. Results: The results indicated PNF Hold relax stretching along with moist heat showed a statistically significant improvement in pain (p<0.05 and improvement in hamstring flexibility (p<0.05 when compared to Static stretching along with moist heat. Conclusion: Subjects with PNF Hold relax stretching along with moist heat showed significant improvement in pain reduction and improving hamstring flexibility than Static stretching along with moist heat.

  20. Do Changes in Patellofemoral Joint Offset Lead to Adverse Outcomes in Total Knee Arthroplasty With Patellar Resurfacing? A Radiographic Review.

    Science.gov (United States)

    Matz, Jacob; Howard, James L; Morden, David J; MacDonald, Steven J; Teeter, Matthew G; Lanting, Brent A

    2017-03-01

    Patellofemoral joint biomechanics contribute to anterior knee pain, instability, and dysfunction following total knee arthroplasty (TKA). Information about specific factors leading to anterior knee pain and dysfunction is currently limited. Changes in patellofemoral joint offset (PFO) refers to a mismatch between the preoperative and postoperative anteroposterior geometry of the patellofemoral joint. It remains unclear whether these changes lead to adverse outcomes in TKA. A retrospective radiographic review of 970 knees pre-TKA and post-TKA was completed to correlate the radiographic and clinical outcomes of changing the PFO using a posterior-stabilized single knee design with patellar resurfacing. A total of 970 patients were reviewed. Postoperatively, the anterior femoral offset, anteroposterior femoral size, and anterior patellar offset were changed in 40%, 60%, and 71% of knees, respectively, compared to preoperative values. The Western Ontario and McMasters Osteoarthritis Index total score as well as subscale scores for pain and function were not significantly affected by an increase or decrease in PFO. Similarly, Knee Society Scores and range of motion were not significantly affected. Increased anterior patellar offset was, however, associated with increased postoperative patellar tilt. Postoperative patellar tilt was not correlated with adverse patient satisfaction scores or loss of range of motion. Changes in PFO (decreased, maintained, or increased) are common post-TKA and are not associated with a difference in clinical outcomes. Increases in anterior patellar offset led to increased patellar tilt, which was not associated with adverse patient satisfaction scores. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Effect of exoskeletal joint constraint and passive resistance on metabolic energy expenditure: Implications for walking in paraplegia.

    Directory of Open Access Journals (Sweden)

    Sarah R Chang

    Full Text Available An important consideration in the design of a practical system to restore walking in individuals with spinal cord injury is to minimize metabolic energy demand on the user. In this study, the effects of exoskeletal constraints on metabolic energy expenditure were evaluated in able-bodied volunteers to gain insight into the demands of walking with a hybrid neuroprosthesis after paralysis. The exoskeleton had a hydraulic mechanism to reciprocally couple hip flexion and extension, unlocked hydraulic stance controlled knee mechanisms, and ankles fixed at neutral by ankle-foot orthoses. These mechanisms added passive resistance to the hip (15 Nm and knee (6 Nm joints while the exoskeleton constrained joint motion to the sagittal plane. The average oxygen consumption when walking with the exoskeleton was 22.5 ± 3.4 ml O2/min/kg as compared to 11.7 ± 2.0 ml O2/min/kg when walking without the exoskeleton at a comparable speed. The heart rate and physiological cost index with the exoskeleton were at least 30% and 4.3 times higher, respectively, than walking without it. The maximum average speed achieved with the exoskeleton was 1.2 ± 0.2 m/s, at a cadence of 104 ± 11 steps/min, and step length of 70 ± 7 cm. Average peak hip joint angles (25 ± 7° were within normal range, while average peak knee joint angles (40 ± 8° were less than normal. Both hip and knee angular velocities were reduced with the exoskeleton as compared to normal. While the walking speed achieved with the exoskeleton could be sufficient for community ambulation, metabolic energy expenditure was significantly increased and unsustainable for such activities. This suggests that passive resistance, constraining leg motion to the sagittal plane, reciprocally coupling the hip joints, and weight of exoskeleton place considerable limitations on the utility of the device and need to be minimized in future designs of practical hybrid neuroprostheses for walking after paraplegia.

  2. Thigh muscle activity, knee motion, and impact force during side-step pivoting in agility-trained female basketball players.

    Science.gov (United States)

    Wilderman, Danielle R; Ross, Scott E; Padua, Darin A

    2009-01-01

    Improving neuromuscular control of hamstrings muscles might have implications for decreasing anterior cruciate ligament injuries in females. To examine the effects of a 6-week agility training program on quadriceps and hamstrings muscle activation, knee flexion angles, and peak vertical ground reaction force. Prospective, randomized clinical research trial. Sports medicine research laboratory. Thirty female intramural basketball players with no history of knee injury (age = 21.07 +/- 2.82 years, height = 171.27 +/- 4.66 cm, mass = 66.36 +/- 7.41 kg). Participants were assigned to an agility training group or a control group that did not participate in agility training. Participants in the agility training group trained 4 times per week for 6 weeks. We used surface electromyography to assess muscle activation for the rectus femoris, vastus medialis oblique, medial hamstrings, and lateral hamstrings for 50 milliseconds before initial ground contact and while the foot was in contact with the ground during a side-step pivot maneuver. Knee flexion angles (at initial ground contact, maximum knee flexion, knee flexion displacement) and peak vertical ground reaction force also were assessed during this maneuver. Participants in the training group increased medial hamstrings activation during ground contact after the 6-week agility training program. Both groups decreased their vastus medialis oblique muscle activation during ground contact. Knee flexion angles and peak vertical ground reaction force did not change for either group. Agility training improved medial hamstrings activity in female intramural basketball players during a side-step pivot maneuver. Agility training that improves hamstrings activity might have implications for reducing anterior cruciate ligament sprain injury associated with side-step pivots.

  3. Effect of spa physiotherapy on the range of motion and muscle strength in women with gonarthrosis.

    Science.gov (United States)

    Lizis, Paweł

    2013-01-01

    Degeneration arthritis is a chronic disease of undetermined progressiveness and unknown pathogenesis. It can affect one or more joints. It reveals itself most frequently between 40 - 60 years of age, and affects the lives of professionally active individuals. The aim of the presented study was to assess the impact of a 21-day stay at a rehabilitation facility on the range of motion and muscle strength of the knee in women with gonarthrosis. The study group consisted of 30 women aged 50-74 years diagnosed with degeneration of the knee joint. The average age of the study group was 65.9 ± 7.2 years. Patients remained in the 21-day rehabilitation facility of Rehabilitational Hospital No. 21 in Busko Zdrój SP ZOZ, Poland. We measured with the help of protractor in SFTR range the motion bending and straightening of the knee with an accuracy of 1°. The Lovett strength test was assessed of the ischio-tibial muscles, quadriceps, sartorius--acting on the knee joint of the patient. The study was carried out on the first and the last day of the stay in the rehabilitation facility. There was improvement in the range of flexion and strength of muscles acting on the knee joint of the afflicted women. The study showed that 21-day rehabilitation holiday improved the range and strength of the muscles acting on the knee joint of the afflicted women. This proved that comprehensive rehabilitation improves the function of the knee joint with gonarthrosis, prevents disease progression and is an alternative to drug therapy.

  4. The importance of position and path repeatability on force at the knee during six-DOF joint motion.

    Science.gov (United States)

    Darcy, Shon P; Gil, Jorge E; Woo, Savio L-Y; Debski, Richard E

    2009-06-01

    Mechanical devices, such as robotic manipulators have been designed to measure joint and ligament function because of their ability to position a diarthrodial joint in six degrees-of-freedom with fidelity. However, the precision and performance of these testing devices vary. Therefore, the objective of this study was to determine the effect of systematic errors in position and path repeatability of two high-payload robotic manipulators (Manipulators 1 and 2) on the resultant forces at the knee. Using a porcine knee, the position and path repeatability of these manipulators were determined during passive flexion-extension with a coordinate measuring machine. The position repeatability of Manipulator 1 was 0.3 mm in position and 0.2 degrees in orientation while Manipulator 2 had a better position repeatability of 0.1 mm in position and 0.1 degrees in orientation throughout the range of positions examined. The corresponding variability in the resultant force at the knee for these assigned positions was 32+/-33 N for Manipulator 1 and 4+/-1 N for Manipulator 2. Furthermore, the repeatability of the trajectory of each manipulator while moving between assigned positions (path repeatability) was 0.8 mm for Manipulator 1 while the path repeatability for Manipulator 2 was improved (0.1 mm). These path discrepancies produced variability in the resultant force at the knee of 44+/-24 and 21+/-8 N, respectively, for Manipulators 1 and 2 primarily due to contact between the articular surfaces of the tibia and femur. Therefore, improved position and path repeatability yields lower variability in the resultant forces at the knee. Although position repeatability has been the most common criteria for evaluating biomechanical testing devices, the current study has clearly demonstrated that path repeatability can have an even larger effect on the variability in resultant force at the knee. Consequently, the repeatability of the path followed by the joint throughout its prescribed

  5. Electrical Properties of PPy-Coated Conductive Fabrics for Human Joint Motion Monitoring

    Directory of Open Access Journals (Sweden)

    Jiyong Hu

    2016-03-01

    Full Text Available Body motion signals indicate several pathological features of the human body, and a wearable human motion monitoring system can respond to human joint motion signal in real time, thereby enabling the prevention and treatment of some diseases. Because conductive fabrics can be well integrated with the garment, they are ideal as a sensing element of wearable human motion monitoring systems. This study prepared polypyrrole conductive fabric by in situ polymerization, and the anisotropic property of the conductive fabric resistance, resistance–strain relationship, and the relationship between resistance and the human knee and elbow movements are discussed preliminarily.

  6. Improvement of the knee center of rotation during walking after opening wedge high tibial osteotomy.

    Science.gov (United States)

    Kim, Kyungsoo; Feng, Jun; Nha, Kyung Wook; Park, Won Man; Kim, Yoon Hyuk

    2015-06-01

    Accurate measurement of the center of rotation of the knee joint is indispensable for prediction of joint kinematics and kinetics in musculoskeletal models. However, no study has yet identified the knee center of rotations during several daily activities before and after high tibial osteotomy surgery, which is one surgical option for treating knee osteoarthritis. In this study, an estimation method for determining the knee joint center of rotation was developed by applying the optimal common shape technique and symmetrical axis of rotation approach techniques to motion-capture data and validated for typical activities (walking, squatting, climbing up stairs, walking down stairs) of 10 normal subjects. The locations of knee joint center of rotations for injured and contralateral knees of eight subjects with osteoarthritis, both before and after high tibial osteotomy surgery, were then calculated during walking. It was shown that high tibial osteotomy surgery improved the knee joint center of rotation since the center of rotations for the injured knee after high tibial osteotomy surgery were significantly closer to those of the normal healthy population. The difference between the injured and contralateral knees was also generally reduced after surgery, demonstrating increased symmetry. These results indicate that symmetry in both knees can be recovered in many cases after high tibial osteotomy surgery. Moreover, the recovery of center of rotation in the injured knee was prior to that of symmetry. This study has the potential to provide fundamental information that can be applied to understand abnormal kinematics in patients, diagnose knee joint disease, and design a novel implants for knee joint surgeries. © IMechE 2015.

  7. Effect of Knee Orthoses on Hamstring Contracture in Children With Cerebral Palsy: Multiple Single-Subject Study.

    Science.gov (United States)

    Laessker-Alkema, Kristina; Eek, Meta Nyström

    2016-01-01

    To examine the effect of knee orthoses on extensibility of the hamstrings in children with spastic cerebral palsy (CP). The short-term effects of knee orthoses on passive range of motion (ROM), spasticity, and gross motor function of the hamstrings. Ten children with spastic CP, aged 5 to 14 years, at Gross Motor Function Classification System levels I to V, were followed. The orthoses were worn for a minimum of 30 minutes day, 5 days per week, during the intervention period of 8 weeks. Visual analysis using the Two Standard Deviation Band Method supported improvements in passive ROM for all 20 hamstring muscles and in 12 of 14 knee extension measurements. Analyses with the Wilcoxon signed rank test confirm the individual results and support a significant increase in hamstring muscles (P = .005) and knee extension (right: P =.028; left: P =.018) compared with baseline. In children with spastic CP, 8 weeks of treatment with knee orthoses can improve extensibility of the hamstrings.

  8. Soft tissue twisting injuries of the knee

    International Nuclear Information System (INIS)

    Magee, T.; Shapiro, M.

    2001-01-01

    Twisting injuries occur as a result of differential motion of different tissue types in injuries with some rotational force. These injuries are well described in brain injuries but, to our knowledge, have not been described in the musculoskeletal literature. We correlated the clinical examination and MR findings of 20 patients with twisting injuries of the soft tissues around the knee. Design and patients: We prospectively followed the clinical courses of 20 patients with knee injuries who had clinical histories and MR findings to suggest twisting injuries of the subcutaneous tissues. Patients with associated internal derangement of the knee (i.e., meniscal tears, ligamentous or bone injuries) were excluded from this study. MR findings to suggest twisting injuries included linear areas of abnormal dark signal on T1-weighted sequences and abnormal bright signal on T2-weighted or short tau inversion recovery (STIR) sequences and/or signal to suggest hemorrhage within the subcutaneous tissues. These MR criteria were adapted from those established for indirect musculotendinous junction injuries. Results: All 20 patients presented with considerable pain that suggested internal derangement on physical examination by the referring orthopedic surgeons. All presented with injuries associated with rotational force. The patients were placed on a course of protected weight-bearing of the affected extremity for 4 weeks. All patients had pain relief by clinical examination after this period of protected weight-bearing. Twisting injuries of the soft tissues can result in considerable pain that can be confused with internal derangement of the knee on physical examination. Soft tissue twisting injuries need to be recognized on MR examinations as they may be the cause of the patient's pain despite no MR evidence of internal derangement of the knee. The demonstration of soft tissue twisting injuries in a patient with severe knee pain but no documented internal derangement on MR

  9. ‘Lumbar Degenerative Kyphosis’ Is Not Byword for Degenerative Sagittal Imbalance: Time to Replace a Misconception

    Science.gov (United States)

    Lee, Chang-Hyun; Chung, Chun Kee; Jang, Jee-Soo; Kim, Sung-Min; Chin, Dong-Kyu; Lee, Jung-Kil

    2017-01-01

    Lumbar degenerative kyphosis (LDK) is a subgroup of the flat-back syndrome and is most commonly caused by unique life styles, such as a prolonged crouched posture during agricultural work and performing activities of daily living on the floor. Unfortunately, LDK has been used as a byword for degenerative sagittal imbalance, and this sometimes causes confusion. The aim of this review was to evaluate the exact territory of LDK, and to introduce another appropriate term for degenerative sagittal deformity. Unlike what its name suggests, LDK does not only include sagittal balance disorder of the lumbar spine and kyphosis, but also sagittal balance disorder of the whole spine and little lordosis of the lumbar spine. Moreover, this disease is closely related to the occupation of female farmers and an outdated Asian life style. These reasons necessitate a change in the nomenclature of this disorder to prevent misunderstanding. We suggest the name “primary degenerative sagittal imbalance” (PDSI), which encompasses degenerative sagittal misalignments of unknown origin in the whole spine in older-age patients, and is associated with back muscle wasting. LDK may be regarded as a subgroup of PDSI related to an occupation in agriculture. Conservative treatments such as exercise and physiotherapy are recommended as first-line treatments for patients with PDSI, and surgical treatment is considered only if conservative treatments failed. The measurement of spinopelvic parameters for sagittal balance is important prior to deformity corrective surgery. LDK can be considered a subtype of PDSI that is more likely to occur in female farmers, and hence the use of LDK as a global term for all degenerative sagittal imbalance disorders is better avoided. To avoid confusion, we recommend PDSI as a newer, more accurate diagnostic term instead of LDK. PMID:28264231

  10. Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients

    Science.gov (United States)

    Hyun, Seung-Jae; Kim, Yongjung J; Rhim, Seung-Chul

    2013-01-01

    In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The long-term overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. PMID:24340276

  11. Knee arthroscopy

    Science.gov (United States)

    ... debridement; Meniscus repair; Lateral release; Knee surgery; Meniscus - arthroscopy; Collateral ligament - arthroscopy ... pain relief (anesthesia) may be used for knee arthroscopy surgery: Local anesthesia. Your knee may be numbed ...

  12. Comparison of Customized Cutting Block and Conventional Cutting Instrument in Total Knee Arthroplasty: A Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Panichkul, Phonthakorn; Kanitnate, Supakit

    2018-03-01

    Customized cutting block (CCB) was designed to ensure the accurate alignment of knee prostheses during total knee arthroplasty. Given the paucity of CCB efficacy data, we compare CCB with conventional cutting guide using a randomized controlled trial. One hundred eight osteoarthritic knee patients underwent total knee arthroplasty by one experienced surgeon were randomized to receive CCB (n = 54) or conventional cutting instrument (CCI) surgery (n = 54). The primary outcomes were limb alignment, prostheses position, and operative time. The secondary outcomes were hemodynamic alteration after surgery, functional outcomes (modified Western Ontario and McMaster University Osteoarthritis Index) and range of motion at 2 years after surgery. Mean hip-knee-ankle angle in the CCB group was 179.4° ± 1.8° vs 179.1° ± 2.4° in the CCI group, Δ = 0 (95% confidence interval [CI] -0.6 to 1.1, P = .55). Mean operative time was faster in the CCB arm: 93 ± 12 vs 104 ± 12 minutes, Δ = 11 (95% CI -16.7 to -7.2, P < .0001). There were no differences in hemodynamic parameters, mean blood loss (446 [CCB] vs 514 mL [CCI], Δ = -68 [95% CI -138 to 31 mL, P = .21]), postoperative hemoglobin changes, incidence of hypotension (systolic <90 mm Hg), oliguria, and rates of blood transfusion. Functional outcomes and range of motion were also similar. There was no improvement in alignment, hemodynamic changes, blood loss, and knee functional outcomes. CCB reduced surgical time by 11 minutes in our population. CCB cost-effectiveness should be further investigated. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Improved knee flexion following high-flexion total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Lionberger David R

    2012-06-01

    Full Text Available Abstract Background The application of new techniques and materials in total knee arthroplasty (TKA continue to be a primary focus in orthopedic surgery. The primary aim of the present study is to evaluate post TKA total range of motion (ROM among a group of patients who received a gender specific high-flexion design modification implant compared to a control group of patients who received non-gender specific implants. Methods and results The control group was comprised of 39 TKAs that were recruited pre-operatively and received the non-gender specific implant while the study group consisted of 39 TKAs who received gender specific implants. The study group yielded an improvement in mean post-operative ROM of 21° at 12 months, whereas the mean improvement in ROM among the control group was 11°. Thus, the study group had a 10° increased ROM improvement (91% over the control group (p = 0.00060. In addition, 100% of the subjects with gender specific high-flexion implants achieved greater or equal ROM post-operatively compared to 82% for the control cohort. Lastly, women who exhibited greater pre-operative ROM and lower body mass index (BMI were found to benefit the most with the gender specific prosthesis. Conclusion Our study demonstrates that among subjects with a normal BMI, the gender specific high-flexion knee implant is associated with increased ROM as compared to the non-gender specific non-high-flexion implant designs.

  14. Hybrid fixation in the bilateral sagittal split osteotomy for lower jaw advancement

    Directory of Open Access Journals (Sweden)

    Felipe Ladeira Pereira

    2010-02-01

    Full Text Available Miniplate and screw fixation has been widely used in bilateral sagittal split osteotomy, but some issues remain unclear concerning its lack of rigidity when compared to Spiessl's bicortical technique. This paper demonstrates the hybrid fixation technique in a case report. A 34-year-old female patient underwent a double jaw surgery with counter-clockwise rotation of the mandible fixed using the hybrid fixation technique. The patient evolved well in the postoperative period and is still under follow up after 14 months, reporting satisfaction with the results and no significant deviation from the treatment plan up to now. No damage to tooth roots was done, maxillomandibular range of motion was within normality and regression of the inferior alveolar nerve paresthesia was observed bilaterally. The hybrid mandibular fixation is clearly visible in the panoramic and cephalometric control radiographs. It seems that the hybrid fixation can sum the advantages of both monocortical and bicortical techniques in lower jaw advancement, increasing fixation stability without significant damage to the mandibular articulation and the inferior alveolar nerve. A statistical investigation seems necessary to prove its efficacy.

  15. Early Progressive Strength Training to Enhance Recovery After Fast-Track Total Knee Arthroplasty

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Kehlet, Henrik; Husted, Henrik

    2014-01-01

    different interventions: 7 weeks of supervised physical rehabilitation with PST (PST group) and without PST (CON group) commenced early after fast-track TKA. The primary outcome was the maximal distance walked in 6 minutes (6-minute walk test). Secondary outcomes were lower extremity strength and power......, knee joint effusion and range of motion, knee pain, and self-reported disability and quality of life. All outcome measures were assessed before TKA (baseline) and 4, 8, and 26 weeks after TKA. RESULTS: There was no statistically significant difference between the PST and CON groups in the change score...

  16. Anterior knee pain

    Science.gov (United States)

    Patellofemoral syndrome; Chondromalacia patella; Runner's knee; Patellar tendinitis; Jumper's knee ... kneecap (patella) sits over the front of your knee joint. As you bend or straighten your knee, ...

  17. Knee Arthrodesis After Failure of Knee Arthroplasty

    DEFF Research Database (Denmark)

    Gottfriedsen, Tinne B; Morville Schrøder, Henrik; Odgaard, Anders

    2016-01-01

    BACKGROUND: Arthrodesis is considered a salvage procedure after failure of a knee arthroplasty. Data on the use of this procedure are limited. The purpose of this study was to identify the incidence, causes, surgical techniques, and outcomes of arthrodesis after failed knee arthroplasty...... in a nationwide population. METHODS: Data were extracted from the Danish Civil Registration System, the Danish National Patient Register, and the Danish Knee Arthroplasty Register. A total of 92,785 primary knee arthroplasties performed in Denmark from 1997 to 2013 were identified by linking the data using....... Differences in cumulative incidence were compared with the Gray test. RESULTS: A total of 164 of the 165 arthrodeses were performed for causes related to failed knee arthroplasty. The 15-year cumulative incidence of arthrodesis was 0.26% (95% confidence interval, 0.21% to 0.31%). The 5-year cumulative...

  18. Does knee awareness differ between different knee arthroplasty prostheses?

    DEFF Research Database (Denmark)

    Thomsen, Morten G; Latifi, Roshan; Kallemose, Thomas

    2016-01-01

    BACKGROUND: Low knee awareness after Total Knee Arthroplasty (TKA) has become the ultimate goal in trying to achieve a natural feeling knee that meet patient expectations. To accommodate this manufacturers of TKAs have developed new prosthetic designs that potentially could give patients a more...... natural feeling knee during activities. The purpose af this study was to compare the Forgotten Joint Score (FJS) and Oxford Knee Score (OKS) of patients treated with a previous generation standard Cruciate Retaining (CR) TKA to the scores obtained by patients treated with a newer generation CR TKA...

  19. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    Science.gov (United States)

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile

  20. Compensatory mechanisms in basketball players with jumper's knee.

    Science.gov (United States)

    Siegmund, Julie A; Huxel, Kellie C; Swanik, C Buz

    2008-11-01

    Determining whether there are compensations in those with jumper's knee (JK) might further our understanding of the condition. Comparing lower extremity kinematics and jump performance of basketball athletes with JK with those of healthy controls (C). Repeated-measures control-match design. University laboratory. 24 male basketball players (12 JK, 12 C) matched by height, weight, position, experience, and frequency of play. Standing counter-movement and running layup jumps. Maximum vertical-jump height, footfall landing, and lower extremity sagittal-plane kinematics. There were no significant group differences (P > .05) in vertical-jump height (JK = 64.3 +/- 8.6 cm, C = 63.0 +/- 9.8 cm) or layup height (JK = 71.3 +/- 11.6 cm, C = 73.3 +/- 11.0 cm). JK subjects landed flat footed (50%) more than controls (8%). JK subjects showed significantly more hip flexion (JK = 105 degrees +/- 24.8 degrees, C = 89.8 degrees +/- 14.1 degrees; P = .039) with decreased hip acceleration during the countermovement (JK = -3039 +/- 1392 degrees /s2, C = -4229 +/- 1765 degrees /s2; P = .040). When landing from the countermovement jump, JK subjects had significantly less knee acceleration (JK = -4960 +/- 1512 degrees/s2, C = -6736 +/- 2009 degrees/s2, P = .023) and in the layup showed significantly less ankle dorsiflexion (JK = 106.5 degrees +/- 9.0 degrees, C = 112.5 degrees +/- 7.7 degrees; P = .048) and hip acceleration (JK = -2841 +/- 1094 degrees/s2, C = -3912 +/- 1575 degrees/s2; P = .033). Compensatory strategies observed in JK subjects might help maintain performance, because their jump height was similar to that of healthy controls.