WorldWideScience

Sample records for safety restraint systems

  1. Continuous restraint control systems: safety improvement for various occupants

    NARCIS (Netherlands)

    Laan, E. van der; Jager, B. de; Veldpaus, F.; Steinbuch, M.; Nunen, E. van; Willemsen, D.

    2009-01-01

    Occupant safety can be significantly improved by continuous restraint control systems. These restraint systems adjust their configuration during the impact according to the actual operating conditions, such as occupant size, weight, occupant position, belt usage and crash severity. In this study,

  2. 76 FR 55825 - Federal Motor Vehicle Safety Standards, Child Restraint Systems

    Science.gov (United States)

    2011-09-09

    ... [Docket No. NHTSA-2011-0139] RIN 2127-AJ44 Federal Motor Vehicle Safety Standards, Child Restraint Systems..., amends a provision in Federal Motor Vehicle Safety Standard No. 213, ``Child restraint systems,'' that... provision: When a motor vehicle safety standard is in effect under this chapter, a State or a political...

  3. 75 FR 71648 - Federal Motor Vehicle Safety Standards, Child Restraint Systems; Hybrid III 10-Year-Old Child...

    Science.gov (United States)

    2010-11-24

    ... No. NHTSA-2010-0158 Regulation Identifier No. (RIN) 2127-AJ44 Federal Motor Vehicle Safety Standards, Child Restraint Systems; Hybrid III 10-Year-Old Child Test Dummy AGENCY: National Highway Traffic Safety... (SNPRM). SUMMARY: This document proposes to amend Federal Motor Vehicle Safety Standard (FMVSS) No. 213...

  4. Overview of the design of core restraint systems

    International Nuclear Information System (INIS)

    Heinecke, J.

    1984-01-01

    The optimization of the core restraint system is an important condition for the safe and reliable operation of a fast breeder reactor. For KNK II which is under successful operation and SNR 300 all requirements for safety and operation have been met with help of a ring type system. For SNR 2 the decision between the ring type system and the free standing core has to be done in the near future. Within these considerations the advantages of a ring type restraint system of limiting deflections during operation and limiting of possible movements under seismic conditions have to be balanced against the somewhat more complicated structure of the ring type restraint system

  5. 32 CFR 636.34 - Restraint systems.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Restraint systems. 636.34 Section 636.34 National... Restraint systems. (a) Restraint systems (seat belts) will be worn by all operators and passengers of U.S. Government vehicles on or off the installations. (b) Restraint systems will be worn by all civilian personnel...

  6. Caregivers’ Use of Child Passenger Safety Resources and Quality of Future Child Restraint System Installations

    Directory of Open Access Journals (Sweden)

    Jessica H. Mirman

    2017-10-01

    Full Text Available Objectives: Child Restraint System (CRS misuse is common. We characterized caregivers’ use of child passenger safety informational and instructional resources and determined whether there were differences in the quality of CRS installations associated with prior exposure to specific resources as evaluated in a standardized CRS installation environment. Methods: Caregivers completed self-report surveys and installed a forward-facing CRS in a controlled environment. Installations were evaluated for security (tightness and accuracy (no errors by a child passenger safety technician (CPST. Results: CRS manuals were the most common way caregivers learned to install a CRS. Primary care providers (PCPs were the most frequently endorsed source of CRS safety information. There was no strong pattern of associations between prior exposure to resources and installation quality (security or accuracy, although some evidence supports protective effects of learning from CPSTs; 13% (19 out of 151 installations were secure and 57% (86 out of 151 installations were accurate. Conclusions: A focus on developing effective and lasting behavioral interventions is needed.

  7. TRANSPORTING CHILDREN IN CARS AND THE USE OF CHILD SAFETY RESTRAINT SYSTEMS.

    Science.gov (United States)

    Garcês, Allan Quadros; Coimbra, Igor Bonifacio Andrade; Silva, Diego Salvador Muniz DA

    2016-01-01

    To evaluate the transport of children in automobiles and the use of child restraints systems (CRS). This is a transversal descriptive study which included 200 vehicle drivers who carried 0-10 year old children in the city of São Luis, MA, Brazil. The drivers' passengers' and children's features were properly identified. The children's transportation using CRS were analyzed according to the Resolution 277/8 of the Brazilian National Traffic Department. The transportation of children was classified as inappropriate in 70.5% of the vehicles analyzed. The most common way for children transportation was free on the back seats (47%) or on the lap of passengers/drivers (17%). The main reasons to justify the improper transportation were either not understanding the importance of CRS use (64.5%) or not having financial resources to buy the devices. The child safety seat was the most used CRS (50.8 %) among vehicles with proper child transportation system. The transportation of children was inappropriate in most of the vehicles analyzed, reflecting the need for creating awareness among automobile drivers, including education, supervision and improvement of policies for health improvement and prevention of accidents involving children transportation. Level of Evidence III, Cross Sectional Study.

  8. Design and optimization for the occupant restraint system of vehicle based on a single freedom model

    Science.gov (United States)

    Zhang, Junyuan; Ma, Yue; Chen, Chao; Zhang, Yan

    2013-05-01

    Throughout the vehicle crash event, the interactions between vehicle, occupant, restraint system (VOR) are complicated and highly non-linear. CAE and physical tests are the most widely used in vehicle passive safety development, but they can only be done with the detailed 3D model or physical samples. Often some design errors and imperfections are difficult to correct at that time, and a large amount of time will be needed. A restraint system concept design approach which based on single-degree-of-freedom occupant-vehicle model (SDOF) is proposed in this paper. The interactions between the restraint system parameters and the occupant responses in a crash are studied from the view of mechanics and energy. The discrete input and the iterative algorithm method are applied to the SDOF model to get the occupant responses quickly for arbitrary excitations (impact pulse) by MATLAB. By studying the relationships between the ridedown efficiency, the restraint stiffness, and the occupant response, the design principle of the restraint stiffness aiming to reduce occupant injury level during conceptual design is represented. Higher ridedown efficiency means more occupant energy absorbed by the vehicle, but the research result shows that higher ridedown efficiency does not mean lower occupant injury level. A proper restraint system design principle depends on two aspects. On one hand, the restraint system should lead to as high ridedown efficiency as possible, and at the same time, the restraint system should maximize use of the survival space to reduce the occupant deceleration level. As an example, an optimization of a passenger vehicle restraint system is designed by the concept design method above, and the final results are validated by MADYMO, which is the most widely used software in restraint system design, and the sled test. Consequently, a guideline and method for the occupant restraint system concept design is established in this paper.

  9. Baseline knowledge on vehicle safety and head restraints among Fleet Managers in British Columbia Canada: a pilot study.

    Science.gov (United States)

    Desapriya, Ediriweera; Hewapathirane, D Sesath; Peiris, Dinithi; Romilly, Doug; White, Marc

    2011-09-01

    Whiplash is the most common injury type arising from motor vehicle collisions, often leading to long-term suffering and disability. Prevention of such injuries is possible through the use of appropriate, correctly positioned, vehicular head restraints. To survey the awareness and knowledge level of vehicle fleet managers in the province of British Columbia, Canada, on the topics of vehicle safety, whiplash injury, and prevention; and to better understand whether these factors influence vehicle purchase/lease decisions. A survey was administered to municipal vehicle fleet managers at a professional meeting (n = 27). Although many respondents understood the effectiveness of vehicle head restraints in the prevention of whiplash injury, the majority rarely adjusted their own headrests. Fleet managers lacked knowledge about the seriousness of whiplash injuries, their associated costs for Canada's healthcare system, and appropriate head restraint positions to mitigate such injuries. The majority of respondents indicated that fleet vehicle purchase/lease decisions within their organization did not factor whiplash prevention as an explicit safety priority. There is relatively little awareness and enforcement of whiplash prevention strategies among municipal vehicle fleet managers.

  10. Poor compliance with child safety restraint use while travelling.

    LENUS (Irish Health Repository)

    Fallon, R

    2011-02-01

    Road traffic accidents are a leading cause of death of children. It is the law that all children should be appropriately secured when traveling in vehicles. The aim of this study was to evaluate parental conformity with these regulations and to test if advice given at a Paediatric outpatient clinic could improve compliance. Two groups were assigned, an intervention group (parents given an information leaflet and a clear explanation about appropriate restraints for their children) and a non-intervention group (received no information). They were contacted again after 2 months and asked regarding compliance. A total of 394 children from 186 families were initially given the questionnaire. Nearly one third of children (29.2%) were not using any restraint while travelling rising to 35.3% on follow up. This study concluded that once off parental education made negligible difference to an already inconsistent and haphazard approach to compliance with safety regulations.

  11. [Injuries caused by traffic accidents: passive safety and restraint systems in automobiles].

    Science.gov (United States)

    Zuppichini, F; Orlandi, E; Genna, M; Rodella, L; Ricci, G; Arienzo, A; Dorrucci, V; Inaspettato, G

    1986-10-01

    In this article are considered the multiple instruments today employed in cars, in order to prevent or ameliorate the lesions caused to the occupants in case of road accident. The acquisitions in the differentiated structure of the car, in the windshield, in the components of the passenger cell are described, and the peculiar importance of the restraint systems is evidenced.

  12. Improving Working Conditions for Astronauts: An Electronic Personal Restraint System for Use in Microgravity Environments

    Directory of Open Access Journals (Sweden)

    Kevin Tait

    2012-01-01

    Full Text Available While in microgravity, astronauts are preoccupied with physical restraint, which takes attention away from the maintenance task or scientific experiment at hand. This may directly lead to safety concerns and increased time for extravehicular activity, as well as potentially inhibit or corrupt data collection. A primary concern is the time it takes to manipulate the current restraint system. The portable foot restraint currently in use by NASA employs a series of pins in order to engage the system or release in an emergency. This requires considerable time for the user to detach, and there is an increased risk of entanglement. If restraint operating time could be reduced by 50%, the astronaut’s assigned experiment time could be increased an average of 100 minutes per mission. Another problem identified by NASA included the inability of the current system to release the user upon failure. Research and design was conducted following the Six-Sigma DMEDI project architecture, and a new form of restraint to replace the existing system was proposed. The research team first studied the customer requirements and relevant standards set by NASA, and with this information they began drafting designs for a solution. This project utilized electromagnetism to restrain a user in microgravity. The proposed system was capable of being manipulated quickly, failing in a manner that released the user, and being electronically controlled. This active electronic control was a new concept in restraint systems, as it enabled an astronaut to effectively “walk” along a surface while remaining restrained to it. With the design prototype and a limited budget, a rudimentary test assembly was built by the team, and most of NASA’s specifications were met. With recommendations from NASA, the research team concluded by developing potential material and design solutions that can be explored in the future by Purdue University or other parties.

  13. Overview of core designs and requirements/criteria for core restraint systems

    International Nuclear Information System (INIS)

    Sutherland, W.H.

    1984-09-01

    The requirements and lifetime criteria for the design of a Liquid Metal Fast Breeder Reactor (LMFBR) Core Restraint System are presented. A discussion of the three types of core restraint systems used in LMFBR core design is given. Details of the core restraint system selected for FFTF are presented and the reasons for this selection given. Structural analysis procedures being used to manage the FFTF assembly irradiations are discussed. Efforts that are ongoing to validate the calculational methods and lifetime criteria are presented

  14. Overview of core designs and requirements/criteria for core restraint systems

    International Nuclear Information System (INIS)

    Sutherland, W.H.

    1984-01-01

    The requirements and lifetime criteria for the design of a Liquid Metal Fast Breeder Reactor (LMFBR) Core Restraint System is presented. A discussion of the three types of core restraint systems used in LMFBR core design is given. Details of the core restraint system selected for FFTF are presented and the reasons for this selection given. Structural analysis procedures being used to manage the FFTF assembly irradiations are discussed. Efforts that are ongoing to validate the calculational methods and lifetime criteria are presented. (author)

  15. High levels of incorrect use of car seat belts and child restraints in Fife--an important and under-recognised road safety issue.

    Science.gov (United States)

    Campbell, H; Macdonald, S; Richardson, P

    1997-03-01

    To pilot data collection instruments and to make a preliminary estimate of the level of incorrect use of car seat belts and child restraints in Fife, Scotland. Cross sectional survey of cars containing adults and children at a number of public sites across Fife in 1995 to assess use of car occupant restraints. Trained road safety officers assessed whether seat restraints were appropriate for the age of the passengers and whether restraints were used correctly. These assessments were based on standards published by the Child Accident Prevention Trust. The survey gathered data from 596 occupants in 180 cars: 327 adults and 269 children. Ten per cent of drivers who were approached refused to participate. Car occupant restraint was assessed in 180 drivers, 151 front seat passengers, and 265 rear seat passengers. Three hundred and sixty one occupants wore seat belts, 68 were restrained by a seat belt and booster cushion, 63 in toddler seats, 25 in two way seats, and 18 in rear facing infant carriers. Ninety seven per cent of drivers, 95% of front seat passengers, and 77% of rear seat passengers were restrained. However, in 98 (52%) vehicles at least one passenger was restrained by a device that was used incorrectly. Seven per cent of adults and 28% of children were secured incorrectly. The commonest errors were loose seat belts and restraint devices not adequately secured to the seat. Rates of incorrect use were highest in child seat restraints, reaching 60% with two way seats and 44% with rear facing infant seats. The incorrect use of car occupant restraints is an under-recognised problem, both by health professionals, and the general public. Incorrect use has been shown to reduce the effectiveness of restraints, can itself result in injury, and is likely to be an important factor in child passenger injuries. The correct use of car seat restraints merits greater attention in strategies aiming to reduce road traffic casualties. Areas of intervention that could be

  16. Evaluation of the influence of seismic restraint characteristics on breeder reactor piping systems

    International Nuclear Information System (INIS)

    Mello, R.M.; Pollono, L.P.

    1979-01-01

    For the Clinch River Breeder Reactor Plant (CRBRP) heat transport system piping within the reactor containment building, dynamic analyses of the piping loops have been performed to study the effect of restraint stiffness on the dynamic behavior of the piping. In addition, analysis and testing of typical CRBRP restraint system components have been performed for the purpose of quantifying and verifying the basic characteristics of the restraints used in the piping system dynamic analysis

  17. Fast Flux Test Facility core restraint system performance

    International Nuclear Information System (INIS)

    Hecht, S.L.; Trenchard, R.G.

    1990-02-01

    Characterizing Fast Flux Test Facility (FFTF) core restraint system performance has been ongoing since the first operating cycle. Characterization consists of prerun analysis for each core load, in-reactor and postirradiation measurements of subassembly withdrawal loads and deformations, and using measurement data to fine tune predictive models. Monitoring FFTF operations and performing trend analysis has made it possible to gain insight into core restraint system performance and head off refueling difficulties while maximizing component lifetimes. Additionally, valuable information for improved designs and operating methods has been obtained. Focus is on past operating experience, emphasizing performance improvements and avoidance of potential problems. 4 refs., 12 figs., 2 tabs

  18. STS-102 Onboard Photograph-The Payload Equipment Restraint System

    Science.gov (United States)

    2001-01-01

    In this Space Shuttle STS-102 mission image, the Payload Equipment Restraint System H-Strap is shown at the left side of the U.S. Laboratory hatch and behind Astronaut James D. Weatherbee, mission specialist. PERS is an integrated modular system of components designed to assist the crew of the International Space Station (ISS) in restraining and carrying necessary payload equipment and tools in a microgravity environment. The Operations Development Group, Flight Projects Directorate at the Marshall Space Flight Center (MSFC), while providing operation support to the ISS Materials Science Research Facility (MSRF), recognized the need for an on-orbit restraint system to facilitate control of lose objects, payloads, and tools. The PERS is the offspring of that need and it helps the ISS crew manage tools and rack components that would otherwise float away in the near-zero gravity environment aboard the Space Station. The system combines Kevlar straps, mesh pockets, Velcro and a variety of cornecting devices into a portable, adjustable system. The system includes the Single Strap, the H-Strap, the Belly Pack, the Laptop Restraint Belt, and the Tool Page Case. The Single Strap and the H-Strap were flown on this mission. The PERS concept was developed by industrial design students at Auburn University and the MSFC Flight Projects Directorate.

  19. Development and testing of restraints for nuclear piping systems

    International Nuclear Information System (INIS)

    Kelly, J.M.; Skinner, M.S.

    1980-06-01

    As an alternative to current practice of pipe restraint within nuclear power plants it has been proposed to adopt restraints capable of dissipating energy in the piping system. The specific mode of energy dissipation focused upon in these studies is the plastic yielding of steels utilizing relative movement between the pipe and the base of the restraint, a general mechanism which has been proven as reliable in several allied studies. This report discusses the testing of examples of two energy-absorbing devices, the results of this testing and the conclusions drawn. This study concentrated on the specific relevant performance characteristics of hysteretic behavior and degradation with use. The testing consisted of repetitive continuous loadings well into the plastic ranges of the devices in a sinusoidal or random displacement controlled mode

  20. CETA truck and EVA restraint system

    Science.gov (United States)

    Beals, David C.; Merson, Wayne R.

    1991-01-01

    The Crew Equipment Translation Aid (CETA) experiment is an extravehicular activity (EVA) Space Transportation System (STS) based flight experiment which will explore various modes of transporting astronauts and light equipment for Space Station Freedom (SSF). The basic elements of CETA are: (1) two 25 foot long sections of monorail, which will be EVA assembled in the STS cargo bay to become a single 50 ft. rail called the track; (2) a wheeled baseplate called the truck which rolls along the track and can accept three cart concepts; and (3) the three carts which are designated manual, electric, and mechanical. The three carts serve as the astronaut restraint and locomotive interfaces with the track. The manual cart is powered by the astronaut grasping the track's handrail and pulling himself along. The electric cart is operated by an astronaut turning a generator which powers the electric motor and drives the cart. The mechanical cart is driven by a Bendix type transmission and is similar in concept to a man-propelled railroad cart. During launch and landing, the truck is attached to the deployable track by means of EVA removable restraint bolts and held in position by a system of retractable shims. These shims are positioned on the exterior of the rail for launch and landing and rotate out of the way for the duration of the experiment. The shims are held in position by strips of Velcro nap, which rub against the sides of the shim and exert a tailored force. The amount of force required to rotate the shims was a major EVA concern, along with operational repeatability and extreme temperature effects. The restraint system was tested in a thermal-vac and vibration environment and was shown to meet all of the initial design requirements. Using design inputs from the astronauts who will perform the EVA, CETA evolved through an iterative design process and represented a cooperative effort.

  1. Use of top tethers with forward-facing child restraints: observations and driver interviews.

    Science.gov (United States)

    Eichelberger, Angela H; Decina, Lawrence E; Jermakian, Jessica S; McCartt, Anne T

    2014-02-01

    Despite the safety benefits, many parents do not use top tethers with forward-facing child restraints. Detailed information was collected about why parents are not using tethers. The sample included 479 drivers who had forward-facing child restraints installed in passenger vehicles equipped with tether anchors. The survey was conducted primarily at shopping centers, recreation facilities, child care facilities, car seat check events, and health care facilities in mostly suburban areas surrounding Philadelphia, Washington, DC, Fredericksburg (VA), and Seattle. Drivers were surveyed about their knowledge and use of tethers and experience with child restraints. Tether use was observed to verify whether tethers were being used correctly. Fifty-six percent of forward-facing child restraints were installed with the tether; 39% were installed with the tether used correctly. The tether was used with 71% of LATCH lower anchor installations and 33% of seat belt installations. Drivers who installed child restraints without tethers most often said they did not know about the tether or how to use it. Although the tether use rate was slightly higher in the current research than in previous studies, many parents and caregivers still use forward-facing child restraints without attaching the tether. Because the main problem is lack of awareness of the tether or how to use it, public education should focus specifically on the safety benefits of tethers and how to use them. Information about why caregivers fail to use top tethers is potentially useful to child restraint manufacturers, child passenger safety technicians, and others who work with parents to improve motor vehicle safety. Copyright © 2013 Elsevier Ltd and National Safety Council. All rights reserved.

  2. Active Head Restraints Used to Improve the Car Seats Safety in a Rear Impact Situation, in Accordance with the Requirements of EURO NCAP

    Directory of Open Access Journals (Sweden)

    D. Yu. Solopov

    2014-01-01

    Full Text Available This article is devoted to the urgent, presently, problem that is to ensure the best level of the passive safety of car seats with active head restraints, as well as to assess the effectiveness of such constructional designs. This is an impact-related task, to be, as a consequence, essentially nonlinear with large deformations, strains and accelerations.To solve this problem finite element models of three types of seat designs with active head restraints have been developed. When creating the simulation FEM a number of CAD (Computer Aided Design/CAE (Computer Aided Engineering software was used.This work was performed within the framework of the developed technique, which allows an efficient creation of the car seat designs with passive and active head restraints that meet requirements of the passive safety.The results of calculations and experiments allowed us to find that the active head restraint significantly reduced a NIC (Neck Injury Criterion value, namely up to 36.92 (4% when using the active headrest with articulated tilting couch, 29.23 (per 24% when using the active headrest with sliding pad, and 26.15 (31% when using the active head restraint, which is provided with an airbag. We have also managed to achieve significantly reduced head acceleration under impact.It was found that FEM seats with active head restraint, which is provided with an airbag, are the most secure because of the least NIC value under the impact (26.15.Presented in the article materials are used in teaching students at the department “Wheeled vehicles” of scientific and educational complex "Special engineering" in BMSTU.

  3. Legislating child restraint usage -Its effect on self-reported child restraint use rates in a central city.

    Science.gov (United States)

    Brixey, Suzanne; Ravindran, Karthik; Guse, Clare E

    2010-02-01

    To assess the effect of the newly enacted child passenger safety law, Wisconsin Act 106, on self-report of proper restraint usage of children in Milwaukee's central city population. A prospective, non-randomized study design was used. The settings used were (a) a pediatric urban health center, and (b) two Women, Infants and Children offices in Milwaukee, Wisconsin. Participants included 11,566 surveys collected over 18 months that spanned the pre-legislation and post-legislation time periods from February 2006 through August 2008. The study set out to assess appropriate child passenger restraint. The results showed that the changes in adjusted proper restraint usage rates for infants between the pre-law, grace period, and post-fine periods were 94%, 94%, and 94% respectively. For children 1-3years old, the adjusted proper usage rates were 65%, 63%, and 59%, respectively. And for children 4-7years old, the rates were 43%, 44% and 42%, respectively. There was a significant increase in premature booster seat use in children who should have been restrained in a rear- or forward-facing car seat (10% pre-law, 12% grace period, 20% post-fine; padvertising and marketing to the correct age group, ease of installation, and mechanisms to prevent incorrect safety strap and harness placement. To ensure accurate and consistent use on every trip, car seat manufacturers must ensure that best practice recommendations for use as well as age, weight, and height be clearly specified on each child restraint. The authors support the United States Department of Transportation's new consumer program that will assist caregivers in identifying the child seat that will fit in their vehicle. In addition, due to the increase in premature graduation of children into belt-positioning booster seats noted as a result of legislation, promoting and marketing booster seat use for children less than 40 pounds should not be accepted. Child passenger safety technicians must continue to promote best

  4. Restraint Use in Older Adults Receiving Home Care.

    Science.gov (United States)

    Scheepmans, Kristien; Dierckx de Casterlé, Bernadette; Paquay, Louis; Van Gansbeke, Hendrik; Milisen, Koen

    2017-08-01

    To determine the prevalence, types, frequency, and duration of restraint use in older adults receiving home nursing care and to determine factors involved in the decision-making process for restraint use and application. Cross-sectional survey of restraint use in older adults receiving home care completed by primary care nurses. Homes of older adults receiving care from a home nursing organization in Belgium. Randomized sample of older adults receiving home care (N = 6,397; mean age 80.6; 66.8% female). For each participant, nurses completed an investigator-constructed and -validated questionnaire collecting information demographic, clinical, and behavioral characteristics and aspects of restraint use. A broad definition of restraint was used that includes a range of restrictive actions. Restraints were used in 24.7% of the participants, mostly on a daily basis (85%) and often for a long period (54.5%, 24 h/d). The most common reason for restraint use was safety (50.2%). Other reasons were that the individual wanted to remain at home longer, which necessitated the use of restraints (18.2%) and to provide respite for the informal caregiver (8.6%). The latter played an important role in the decision and application process. The physician was less involved in the process. In 64.5% of cases, there was no evaluation after restraint use was initiated. Use of restraints is common in older adults receiving home care nursing in Belgium. These results contribute to a better understanding of the complexity of use of restraints in home care, a situation that may be even more complex than in nursing homes and acute hospital settings. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  5. Comparative product testing of children's restraint systems, with inclusion of side-collision tests

    Energy Technology Data Exchange (ETDEWEB)

    Goerlitz, H. [Stiftung Warentest, Berlin (Germany); Noeske, V. [DEKRA Dresden (Germany)

    2001-07-01

    Stiftung Warentest has conducted comparative product testing for Group 0.. III child car seats to evaluate accident protection, handling, comfort of the seats, and safety against faulty use. The tests that were conducted were intended to provide assessment of product quality. Owing to great reader interest, tests conducted on child car seats have become well established for a considerable number of years now. They enjoy esteemed status, for example, in our magazine test. Stiftung Warentest conducted its first tests on children's restraint system many years ago: in May of 1968. The great interest in this topic, as evidenced by widespread feedback from readers, justifies the high costs occasioned by the dynamic testing of children's restraint systems. The popularity of this topic leads to greater sales of the particular issues of the magazine test - which carries no advertising - and at least compensates for most of the added costs necessary for dynamic collision testing. It is not generally well known that Stiftung Warentest covers approximately 90% of its budget from the sales of its two magazines test and Finanztest, and of its other special publications. The annual subsidy by the German government is relatively small. The national subsidy is intended to compensate for the loss of revenue from the exclusion of advertising. (orig.)

  6. [Medical-legal issues of physical and pharmacological restraint].

    Science.gov (United States)

    Gómez-Durán, Esperanza L; Guija, Julio A; Ortega-Monasterio, Leopoldo

    2014-03-01

    The use of physical and pharmacological restraint is controversial but is currently accepted as inevitable. It is indicated for controlling behavioral disorders and psychomotor agitation that put patients and third parties at risk. Its indication should be medical, and we should opt for the least restrictive measure. Restraints represent a possible infringement of patients' fundamental rights and require understanding and strict respect for the medical-legal precepts by physicians and other practitioners involved in its application. This article reviews the current legal framework, as well as the medical-legal premises and aspects of applying restraints, with the objective of ensuring maximum respect for patients' rights and the appropriate legal safety in the activity of practitioners. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  7. A prospective study of children aged children and are associated with restraint misuse.

    Science.gov (United States)

    Skjerven-Martinsen, Marianne; Naess, Paal Aksel; Hansen, Trond Boye; Gaarder, Christine; Lereim, Inggard; Stray-Pedersen, Arne

    2014-12-01

    The implementation of the compulsory wearing of seat belts (SBs) for children and improvements in child restraint systems have reduced the number of deaths and severe injuries among children involved in motor vehicle (MV) collisions (MVCs). Establishing the characteristics predictive of such injuries may provide the basis for targeted safety campaigns and lead to a further reduction in mortality and morbidity among children involved in MVCs. This study performed a multidisciplinary investigation among child occupants involved in MVCs to elucidate injury mechanisms, evaluate the safety measures used and determine the characteristics that are predictive of injury. A prospective study was conducted of all child occupants aged interior of the MVs were investigated and the injured children were medically examined. Supplementary information was obtained from witnesses, the crash victims, police reports, medical records and reconstructions. Each case was reviewed by a multidisciplinary team to assess the mechanism of injury. In total, 158 child occupants involved in 100 MVCs were investigated, of which 27 (17%) exhibited Abbreviated Injury Scale (AIS) scores of 2+ injuries and 15 (9%) exhibited AIS 3+ injuries. None of the children died. Of those with AIS 2+ injuries (n=27), 89% (n=24) were involved in frontal impact collisions and 11% (3/27) were involved in side impacts. Multivariate analysis revealed that restraint misuse, age, the prevailing lighting conditions and ΔV were all independently correlated with AIS 2+ injuries. Safety errors were found in 74% (20/27) of those with AIS 2+ injuries and 93% (14/15) of those with AIS 3+ injuries. The most common safety error was misuse of restraints, and in particular loose and/or improperly positioned SBs. The risk of injury among child occupants is significantly higher when the child occupants are exposed to safety errors within the interior of the vehicle. Future campaigns should focus on the prevention of restraint misuse

  8. Prehospital chemical restraint of a noncommunicative autistic minor by law enforcement.

    Science.gov (United States)

    Ho, Jeffrey D; Nystrom, Paul C; Calvo, Darryl V; Berris, Marc S; Norlin, Jeffrey F; Clinton, Joseph E

    2012-01-01

    When responders are dealing with an agitated patient in the field, safety for all involved may sometimes only be accomplished with physical or chemical restraints. While experiences using chemical restraint in the prehospital setting are found in the medical literature, the use of this by law enforcement as a first-response restraint has not previously been described. We report a case of successful law enforcement-administered sedation of a noncommunicative, autistic, and violent minor using intramuscular droperidol and diphenhydramine. Although this case has some unique characteristics that allowed chemical restraint to be given by the law enforcement agency, it calls attention to some specific prehospital issues that need to be addressed when dealing with autistic patients with extreme agitation.

  9. National roadside survey of child restraint system use in Belgium.

    Science.gov (United States)

    Mathieu, Roynard; Peter, Silverans; Yvan, Casteels; Philippe, Lesire

    2014-01-01

    In September 2011 the Belgian Road Safety Institute (BRSI) conducted its first roadside survey of child restraint system (CRS) use and misuse. The aim of this study was to obtain population-bases estimates of the prevalence of use and misuse of CRS and to identify predictors of misuse on the basis of observations in real traffic conditions. The survey was conducted on randomly selected sites across the country, stratified across various types of journeys. The principal parameters analysed were: the characteristics of the children and the car drivers, type of journey, types of CRS and types of misuse. The sample consisted of 1461 children (under 135cm) for whom the conditions of restraint were observed in detail and the driver was interviewed. At least 50% of the children were not correctly restrained and 10% were not restrained at all. The most significant factors associated with CRS use were the use of a seatbelt by the driver (31% of unrestrained children for unbelted drivers, compared to 7% for belted drivers - only 32% of correctly restrained children for unbelted drivers compared to 54% for belted drivers), whether the CRS was bought in a specialized shop (only 27% of misuse compared to 45% of misuse for CRS both in supermarkets) and the age of the children. The proportion of correctly restrained children (appropriate without misuse, the bottom category in the figure) has a roughly curvilinear relation with age; decreasing from 75% at age 0 to 24% at age 8 and going back up to 63% at age 10. Although the sample of ISOFIX users was small (n=76), it appears that the ISOFIX system reduced misuse significantly. Most of the drivers were ignorant of their own errors concerning the inappropriateness and/or misuse of the CRS or they were remiss and underestimated the risk. The three main reasons given by the drivers to explain or justify the misuse noticed were: low attention level to safety (inattention, time pressure, and short distance), the child's resistance to

  10. Can child restraint product information developed using consumer testing sustain correct use 6 months after child restraint purchase? Study protocol for a cluster randomised controlled trial.

    Science.gov (United States)

    Brown, Julie; Elkington, Jane; Hall, Alexandra; Keay, Lisa; Charlton, Judith L; Hunter, Kate; Koppel, Sjaan; Hayen, Andrew; Bilston, Lynne E

    2018-03-07

    With long-standing and widespread high rates of errors in child restraint use, there is a need to identify effective methods to address this problem. Information supplied with products at the point of sale may be a potentially efficient delivery point for such a countermeasure. The aim of this study is to establish whether product materials developed using a consumer-driven approach reduce errors in restraint use among purchasers of new child restraint systems. A cluster randomised controlled trial (cRCT) will be conducted. Retail stores (n=22) in the greater Sydney area will be randomised into intervention sites (n=11) and control sites (n=11), stratified by geographical and socioeconomic indicators. Participants (n=836) will enter the study on purchase of a restraint. Outcome measures are errors in installation of the restraint as observed by a trained researcher during a 6-month follow-up home assessment, and adjustment checks made by the parent when the child is placed into the restraint (observed using naturalistic methods). Process evaluation measures will also be collected during the home visit. An intention-to-treat approach will be used for all analyses. Correct use and adjustment checks made by the parent will be compared between control and intervention groups using a logistic regression model. The number of installation errors between groups will be compared using Poisson regression. This cRCT will determine the effectiveness of targeted, consumer-driven information on actual error rates in use of restraints. More broadly, it may provide a best practice model for developing safety product information. ACTRN12617001252303p; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. New research opportunities for roadside safety barriers improvement

    Science.gov (United States)

    Cantisani, Giuseppe; Di Mascio, Paola; Polidori, Carlo

    2017-09-01

    Among the major topics regarding the protection of roads, restraint systems still represent a big opportunity in order to increase safety performances. When accidents happen, in fact, the infrastructure can substantially contribute to the reduction of consequences if its marginal spaces are well designed and/or effective restraint systems are installed there. Nevertheless, basic concepts and technology of road safety barriers have not significantly changed for the last two decades. The paper proposes a new approach to the study aimed to define possible enhancements of restraint safety systems performances, by using new materials and defining innovative design principles. In particular, roadside systems can be developed with regard to vehicle-barrier interaction, vehicle-oriented design (included low-mass and extremely low-mass vehicles), traffic suitability, user protection, working width reduction. In addition, thanks to sensors embedded into the barriers, it is also expected to deal with new challenges related to the guidance of automatic vehicles and I2V communication.

  12. Restraint use in older adults in home care: A systematic review.

    Science.gov (United States)

    Scheepmans, Kristien; Dierckx de Casterlé, Bernadette; Paquay, Louis; Milisen, Koen

    2018-03-01

    To get insight into restraint use in older adults receiving home care and, more specifically, into the definition, prevalence and types of restraint, as well as the reasons for restraint use and the people involved in the decision-making process. Systematic review. Four databases (i.e. Pubmed, CINAHL, Embase, Cochrane Library) were systematically searched from inception to end of April 2017. The study encompassed qualitative and quantitative research on restraint use in older adults receiving home care that reported definitions of restraint, prevalence of use, types of restraint, reasons for use or the people involved. We considered publications written in English, French, Dutch and German. One reviewer performed the search and made the initial selection based on titles and abstracts. The final selection was made by two reviewers working independently; they also assessed study quality. We used an integrated design to synthesise the findings. Eight studies were reviewed (one qualitative, seven quantitative) ranging in quality from moderate to high. The review indicated there was no single, clear definition of restraint. The prevalence of restraint use ranged from 5% to 24.7%, with various types of restraint being used. Families played an important role in the decision-making process and application of restraints; general practitioners were less involved. Specific reasons, other than safety for using restraints in home care were noted (e.g. delay to nursing home admission; to provide respite for an informal caregiver). Contrary to the current socio demographical evolutions resulting in an increasing demand of restraint use in home care, research on this subject is still scarce and recent. The limited evidence however points to the challenging complexity and specificity of home care regarding restraint use. Given these serious challenges for clinical practice, more research about restraint use in home care is urgently needed. Copyright © 2017. Published by Elsevier

  13. Predictors of restraint use among child occupants.

    Science.gov (United States)

    Benedetti, Marco; Klinich, Kathleen D; Manary, Miriam A; Flannagan, Carol A

    2017-11-17

    The objective of this study was to identify factors that predict restraint use and optimal restraint use among children aged 0 to 13 years. The data set is a national sample of police-reported crashes for years 2010-2014 in which type of child restraint is recorded. The data set was supplemented with demographic census data linked by driver ZIP code, as well as a score for the state child restraint law during the year of the crash relative to best practice recommendations for protecting child occupants. Analysis used linear regression techniques. The main predictor of unrestrained child occupants was the presence of an unrestrained driver. Among restrained children, children had 1.66 (95% confidence interval, 1.27, 2.17) times higher odds of using the recommended type of restraint system if the state law at the time of the crash included requirements based on best practice recommendations. Children are more likely to ride in the recommended type of child restraint when their state's child restraint law includes wording that follows best practice recommendations for child occupant protection. However, state child restraint law requirements do not influence when caregivers fail to use an occupant restraint for their child passengers.

  14. Comparative Assessment of Torso and Seat Mounted Restraint Systems using Manikins on the Vertical Deceleration Tower

    Science.gov (United States)

    2017-03-01

    AFRL-RH-WP-TR-2017-0044 Comparative Assessment of Torso and Seat Mounted Restraint Systems using Manikins on the Vertical ...Restraint Systems using Manikins on the Vertical Deceleration Tower 5a. CONTRACT NUMBER FA8650-14-D-6500-0001 5b. GRANT NUMBER 5c. PROGRAM...experimental effort involving a series of +z-axis impact tests was conducted on the 711th Human Performance Wing’s Vertical Deceleration Tower (VDT

  15. Core mechanics and configuration behavior of advanced LMFBR core restraint concepts

    International Nuclear Information System (INIS)

    Fox, J.N.; Wei, B.C.

    1978-02-01

    Core restraint systems in LMFBRs maintain control of core mechanics and configuration behavior. Core restraint design is complex due to the close spacing between adjacent components, flux and temperature gradients, and irradiation-induced material property effects. Since the core assemblies interact with each other and transmit loads directly to the core restraint structural members, the core assemblies themselves are an integral part of the core restraint system. This paper presents an assessment of several advanced core restraint system and core assembly concepts relative to the expected performance of currently accepted designs. A recommended order for the development of the advanced concepts is also presented

  16. Association between weight and risk of crash-related injuries for children in child restraints.

    Science.gov (United States)

    Zonfrillo, Mark R; Elliott, Michael R; Flannagan, Carol A; Durbin, Dennis R

    2011-12-01

    To determine the association between weight and the risk of injury in motor vehicle crashes (MVCs) for children 1 through 8 years of age who were using child restraints. This was a cross-sectional study of children 1 to 8 years of age in MVCs, in which cases from the National Automotive Sampling System Crashworthiness Data System were used. Abbreviated Injury Scale scores of ≥2 indicated clinically significant injuries. The National Automotive Sampling System Crashworthiness Data System study sample included 650 children 1 to 5 years of age in forward-facing child restraints who weighed 20 to 65 lb and 344 children 3 to 8 years of age in belt-positioning booster seats who weighed 30 to 100 lb. With adjustment for seating position, type of vehicle, direction of impact, crash severity, and vehicle model year, there was no association between absolute weight and clinically significant injuries in either age group (odds ratio: 1.17 [95% confidence interval: 0.96-1.42] for children 1-5 years of age in forward-facing child restraints and 1.22 [95% confidence interval: 0.96-1.55] for children 3-8 years of age in belt-positioning booster seats). The risk of clinically significant injuries was not associated with weight across a broad weight range in this sample of children in MVCs who were using child restraint systems. Parents should continue to restrain their children according to current recommendations from the American Academy of Pediatrics and the National Highway Traffic Safety Administration.

  17. Seismic restraint means for radiation detector

    International Nuclear Information System (INIS)

    Underwood, R.H.; Todt, W.H.

    1983-01-01

    Seismic restraint means are provided for mounting an elongated, generally cylindrical nuclear radiation detector within a tubular thimble in a nuclear reactor monitor system. The restraint means permits longitudinal movement of the radiation detector into and out of the thimble. Each restraint means comprises a split clamp ring and a plurality of symmetrically spaced support arms pivotally mounted on the clamp ring. Each support arm has spring bias means and thimble contact means eg insulating rollers whereby the contact means engage the thimble with a constant predetermined force which minimizes seismic vibration action on the radiation detector. (author)

  18. Mechanical restraint in psychiatry

    DEFF Research Database (Denmark)

    Bak, Jesper; Zoffmann, Vibeke; Sestoft, Dorte Maria

    2014-01-01

    PURPOSE: To examine how potential mechanical restraint preventive factors in hospitals are associated with the frequency of mechanical restraint episodes. DESIGN AND METHODS: This study employed a retrospective association design, and linear regression was used to assess the associations. FINDINGS......: Three mechanical restraint preventive factors were significantly associated with low rates of mechanical restraint use: mandatory review (exp[B] = .36, p mechanical...

  19. 36 CFR 1004.15 - Safety belts.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Safety belts. 1004.15 Section 1004.15 Parks, Forests, and Public Property PRESIDIO TRUST VEHICLES AND TRAFFIC SAFETY § 1004.15 Safety... administered by the Presidio Trust will have the safety belt or child restraint system properly fastened at all...

  20. Acute Cold / Restraint Stress in Castrated Rats

    Directory of Open Access Journals (Sweden)

    Farideh Zafari Zangeneh

    2008-09-01

    Full Text Available Objective: The present study aimed to determine whether castration altered osmotically stimulated vasopressin (VP release and urinary volume and what is the role of endocrine-stress axis in this process.Materials and methods: Totally 108 mice were studied in two main groups of castrated (n=78 and control (n=30. Each group was extracted by acute cold stress (4◦C for 2h/day, restraint stress (by syringes 60cc 2h/day and cold/restraint stress. The castrated group was treated in sub groups of testosterone, control (sesame oil as vehicle of testosterone. Propranolol as blocker of sympathetic nervous system was given to both groups of castrated mice and main control.Results: Our results showed that, there is interactions between testosterone and sympathetic nervous system on vasopressin, because urine volume was decreased only in testoctomized mice with cold/restraint and cold stress (P<0.001; propranolol as the antagonist of sympathetic nervous system could block and increase urine volume in castrated mice. This increased volume of urine was due to acute cold stress, not restraint stress (p<0.001. The role of testosterone, noradrenalin (NA and Vasopressin (VP in the acute cold stress is confirmed, because testosterone could return the effect of decreased urine volume in control group (P<0.001. Conclusion: Considering the effect of cold/restraint stress on urinary volume in castrated mice shows that there is interaction between sex hormone (testosterone, vasopressin and adrenergic systems.

  1. 36 CFR 4.15 - Safety belts.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Safety belts. 4.15 Section 4... TRAFFIC SAFETY § 4.15 Safety belts. (a) Each operator and passenger occupying any seating position of a motor vehicle in a park area will have the safety belt or child restraint system properly fastened at...

  2. Knowledge and application of correct car seat head restraint usage among chiropractic college interns: a cross-sectional study.

    Science.gov (United States)

    Taylor, John Am; Burke, Jeanmarie; Gavencak, John; Panwar, Pervinder

    2005-03-01

    Cervical spine injuries sustained in rear-end crashes cost at least $7 billion in insurance claims annually in the United States alone. When positioned correctly, head restraint systems have been proven effective in reducing the risk of whiplash associated disorders. Chiropractors should be knowledgeable about the correct use of head restraint systems to educate their patients and thereby prevent or minimize such injuries. The primary objective of this study was to determine the prevalence of correct positioning of car seat head restraints among the interns at our institution. The secondary objective was to determine the same chiropractic interns' knowledge of the correct positioning of car seat head restraints. It was hypothesized that 100 percent of interns would have their head restraint correctly positioned within an acceptable range and that all interns would possess the knowledge to instruct patients in the correct positioning of head restraints. Cross-sectional study of a convenient sample of 30 chiropractic interns from one institution. Interns driving into the parking lot of our health center were asked to volunteer to have measurements taken and to complete a survey. Vertical and horizontal positions of the head restraint were measured using a beam compass. A survey was administered to determine knowledge of correct head restraint position. The results were recorded, entered into a spreadsheet, and analyzed. 13.3 percent of subjects knew the recommended vertical distance and only 20 percent of subjects knew the recommended horizontal distance. Chi Square analyses substantiated that the majority of subjects were unaware of guidelines set forth by the National Highway Traffic Safety Administration (NHTSA) for the correct positioning of the head restraint (chi(2) (vertical) = 16.13, chi(2) (horizontal) = 10.80, p .05). Interestingly, the 13.3 percent of the subjects who were aware of the vertical plane recommendations did not correctly position their own

  3. Supporting system for the core restraint of nuclear reactors

    International Nuclear Information System (INIS)

    Kaser, A.

    1973-01-01

    The core restraint of water cooled nuclear reactors which is needed to direct the flow of the coolant through the core can be manufactured only in a moderate wall thickness. Thus, the majority of the loads have to be transmitted to the core barrel which is more rigid. The patent refers to a system of circumferential and vertical support members most of which are free to move relatively to each other, thus reducing thermal stresses during operation. (P.K.)

  4. Cholinergic Modulation of Restraint Stress Induced Neurobehavioral ...

    African Journals Online (AJOL)

    The involvement of the cholinergic system in restraint stress induced neurobehavioral alterations was investigated in rodents using the hole board, elevated plus maze, the open field and the light and dark box tests. Restraint stress (3h) reduced significantly (p<0.05) the number of entries and time spent in the open arm, ...

  5. Mechanical Restraint - Which Interventions Prevent Episodes of Mechanical Restraint? - A Systematic Review

    DEFF Research Database (Denmark)

    Bak, Jesper; Brandt-Christensen, Anne Mette; Sestoft, Dorte Maria

    2012-01-01

    PURPOSE:  To identify interventions preventing mechanical restraints. DESIGN AND METHODS:  Systematic review of international research papers dealing with mechanical restraint. The review combines qualitative and quantitative research in a new way, describing the quality of evidence and the effect...... of intervention. FINDINGS:  Implementation of cognitive milieu therapy, combined interventions, and patient-centered care were the three interventions most likely to reduce the number of mechanical restraints. PRACTICE IMPLICATIONS:  There is a lack of high-quality and effective intervention studies. This leaves...... patients and metal health professionals with uncertainty when choosing interventions in an attempt to prevent mechanical restraints....

  6. [Therapeutic restraint management in Intensive Care Units: Phenomenological approach to nursing reality].

    Science.gov (United States)

    Acevedo-Nuevo, M; González-Gil, M T; Solís-Muñoz, M; Láiz-Díez, N; Toraño-Olivera, M J; Carrasco-Rodríguez-Rey, L F; García-González, S; Velasco-Sanz, T R; Martínez-Álvarez, A; Martin-Rivera, B E

    2016-01-01

    To identify nursing experience on physical restraint management in Critical Care Units. To analyse similarities and differences in nursing experience on physical restraint management according to the clinical context that they are involved in. A multicentre phenomenological study was carried out including 14 Critical Care Units in Madrid, classified according to physical restraint use: Common/systematic use, lacking/personalised use, and mixed use. Five focus groups (23 participants were selected following purposeful sampling) were convened, concluding in data saturation. Data analysis was focused on thematic content analysis following Colaizzi's method. Six main themes: Physical restraint meaning in Critical Care Units, safety (self-retreat vital devices), contribution factors, feelings, alternatives, and pending issues. Although some themes are common to the 3 Critical Care Unit types, discourse differences are found as regards to indication, feelings, systematic use of pain and sedation measurement tools. In order to achieve real physical restraint reduction in Critical Care Units, it is necessary to have a deep understanding of restraints use in the specific clinical context. As self-retreat vital devices emerge as central concept, some interventions proposed in other settings could not be effective, requiring alternatives for critical care patients. Discourse variations laid out in the different Critical Care Unit types could highlight key items that determine the use and different attitudes towards physical restraint. Copyright © 2015 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  7. Time to death analysis of road traffic accidents in relation to delta V, drunk driving, and restraint systems.

    Science.gov (United States)

    Ju, Yonghan; Sohn, So Young

    2014-01-01

    The main goal of this research is to identify variables related to the expected time to death due to road traffic accidents (RTAs). Such research is expected to be useful in improving safety laws and regulations and developing new safety systems. The resulting information is crucial not only for reducing accident fatalities but for assessing related insurance policies. In this article, we analyze factors that are potentially associated with variation in the expected survival time after a road traffic accident using Weibull regression. In particular, we consider the association with alcohol involvement, delta V, and restraint systems. Our empirical results, obtained based on the NASS-CDS, indicate that the expected survival time for non-alcohol-impaired drivers is 3.23 times longer at a delta V of 50 km/h than that for alcohol-impaired drivers under the same conditions. In addition, it was observed that, even when occupants were alcohol-impaired, if they were protected by both air bags and seat belts, their expected survival time after an RTA increased 2.59-fold compared to alcohol-impaired drivers who used only seat belts. Our findings may be useful in improving road traffic safety and insurance policies by offering insights into the factors that reduce fatalities.

  8. Restraint stress enhances arterial thrombosis in vivo--role of the sympathetic nervous system.

    Science.gov (United States)

    Stämpfli, Simon F; Camici, Giovanni G; Keller, Stephan; Rozenberg, Izabela; Arras, Margarete; Schuler, Beat; Gassmann, Max; Garcia, Irene; Lüscher, Thomas F; Tanner, Felix C

    2014-01-01

    Stress is known to correlate with the incidence of acute myocardial infarction. However, the molecular mechanisms underlying this correlation are not known. This study was designed to assess the effect of experimental stress on arterial thrombus formation, the key event in acute myocardial infarction. Mice exposed to 20 h of restraint stress displayed an increased arterial prothrombotic potential as assessed by photochemical injury-induced time to thrombotic occlusion. This increase was prevented by chemical sympathectomy performed through 6-hydroxydopamine (6-OHDA). Blood-born tissue factor (TF) activity was enhanced by stress and this increase could be prevented by 6-OHDA treatment. Vessel wall TF, platelet count, platelet aggregation, coagulation times (PT, aPTT), fibrinolytic system (t-PA and PAI-1) and tail bleeding time remained unaltered. Telemetric analysis revealed only minor hemodynamic changes throughout the stress protocol. Plasma catecholamines remained unaffected after restraint stress. Tumor necrosis factor alpha (TNF-α) plasma levels were unchanged and inhibition of TNF-α had no effect on stress-enhanced thrombosis. These results indicate that restraint stress enhances arterial thrombosis via the sympathetic nervous system. Blood-borne TF contributes, at least in part, to the observed effect whereas vessel wall TF, platelets, circulating coagulation factors, fibrinolysis and inflammation do not appear to play a role. These findings shed new light on the understanding of stress-induced cardiovascular events.

  9. Gold Mine or Minefield: Understanding Russian Law on Vertical Restraints

    Directory of Open Access Journals (Sweden)

    Valentina Rucker

    2014-01-01

    Full Text Available While the Russian Federation represents a significant opportunity for growth, that opportunity is coupled with serious risks. As it relates to managing product distribution, Russian vertical restraint law remains significantly more restrictive than that of the U.S. and, since unless a company is fully integrated, it must manage its distribution system by way of vertical agreements, presents a large problem for businesses seeking to conduct business in Russia. While Russia has made significant steps in the right direction, the lack of consistent application of economic analysis to evaluation of vertical restraints leaves companies exposed. Further, the sometimes inconsistent application of the laws also makes it hard to predict how any particular vertical agreement would be evaluated. Neither American nor Russian antitrust laws establish a list of possible vertical restraints. Thus, there is no exhaustive guidance regarding how these restraints should be treated. U.S. antitrust laws, however, generally place all vertical restraints into one of two categories, intrabrand restraints and interbrand restraints. Intrabrand restraints are those that restrain the downstream firm’s freedom with regard to the resale of the product at issue (distribution restrictions. Interbrand restraints are those that restrict a downstream or upstream firm’s freedom to deal with competitors of the firm imposing the restraint (interbrand restrictions. It should be noted that Russian law does not make this distinction.

  10. Gold Mine or Minefield: Understanding Russian Law on Vertical Restraints

    Directory of Open Access Journals (Sweden)

    Valentina Rucker

    2015-02-01

    Full Text Available While the Russian Federation represents a significant opportunity for growth, that opportunity is coupled with serious risks. As it relates to managing product distribution, Russian vertical restraint law remains significantly more restrictive than that of the U.S. and, since unless a company is fully integrated, it must manage its distribution system by way of vertical agreements, presents a large problem for businesses seeking to conduct business in Russia. While Russia has made significant steps in the right direction, the lack of consistent application of economic analysis to evaluation of vertical restraints leaves companies exposed. Further, the sometimes inconsistent application of the laws also makes it hard to predict how any particular vertical agreement would be evaluated. Neither American nor Russian antitrust laws establish a list of possible vertical restraints. Thus, there is no exhaustive guidance regarding how these restraints should be treated. U.S. antitrust laws, however, generally place all vertical restraints into one of two categories, intrabrand restraints and interbrand restraints. Intrabrand restraints are those that restrain the downstream firm’s freedom with regard to the resale of the product at issue (distribution restrictions. Interbrand restraints are those that restrict a downstream or upstream firm’s freedom to deal with competitors of the firm imposing the restraint (interbrand restrictions. It should be noted that Russian law does not make this distinction.

  11. PDBStat: a universal restraint converter and restraint analysis software package for protein NMR

    International Nuclear Information System (INIS)

    Tejero, Roberto; Snyder, David; Mao, Binchen; Aramini, James M.; Montelione, Gaetano T.

    2013-01-01

    The heterogeneous array of software tools used in the process of protein NMR structure determination presents organizational challenges in the structure determination and validation processes, and creates a learning curve that limits the broader use of protein NMR in biology. These challenges, including accurate use of data in different data formats required by software carrying out similar tasks, continue to confound the efforts of novices and experts alike. These important issues need to be addressed robustly in order to standardize protein NMR structure determination and validation. PDBStat is a C/C++ computer program originally developed as a universal coordinate and protein NMR restraint converter. Its primary function is to provide a user-friendly tool for interconverting between protein coordinate and protein NMR restraint data formats. It also provides an integrated set of computational methods for protein NMR restraint analysis and structure quality assessment, relabeling of prochiral atoms with correct IUPAC names, as well as multiple methods for analysis of the consistency of atomic positions indicated by their convergence across a protein NMR ensemble. In this paper we provide a detailed description of the PDBStat software, and highlight some of its valuable computational capabilities. As an example, we demonstrate the use of the PDBStat restraint converter for restrained CS-Rosetta structure generation calculations, and compare the resulting protein NMR structure models with those generated from the same NMR restraint data using more traditional structure determination methods. These results demonstrate the value of a universal restraint converter in allowing the use of multiple structure generation methods with the same restraint data for consensus analysis of protein NMR structures and the underlying restraint data

  12. PDBStat: a universal restraint converter and restraint analysis software package for protein NMR

    Energy Technology Data Exchange (ETDEWEB)

    Tejero, Roberto [Rutgers, The State University of New Jersey, Center for Advanced Biotechnology and Medicine (United States); Snyder, David [William Paterson University, Department of Chemistry (United States); Mao, Binchen; Aramini, James M.; Montelione, Gaetano T., E-mail: guy@cabm.rutgers.edu [Rutgers, The State University of New Jersey, Center for Advanced Biotechnology and Medicine (United States)

    2013-08-15

    The heterogeneous array of software tools used in the process of protein NMR structure determination presents organizational challenges in the structure determination and validation processes, and creates a learning curve that limits the broader use of protein NMR in biology. These challenges, including accurate use of data in different data formats required by software carrying out similar tasks, continue to confound the efforts of novices and experts alike. These important issues need to be addressed robustly in order to standardize protein NMR structure determination and validation. PDBStat is a C/C++ computer program originally developed as a universal coordinate and protein NMR restraint converter. Its primary function is to provide a user-friendly tool for interconverting between protein coordinate and protein NMR restraint data formats. It also provides an integrated set of computational methods for protein NMR restraint analysis and structure quality assessment, relabeling of prochiral atoms with correct IUPAC names, as well as multiple methods for analysis of the consistency of atomic positions indicated by their convergence across a protein NMR ensemble. In this paper we provide a detailed description of the PDBStat software, and highlight some of its valuable computational capabilities. As an example, we demonstrate the use of the PDBStat restraint converter for restrained CS-Rosetta structure generation calculations, and compare the resulting protein NMR structure models with those generated from the same NMR restraint data using more traditional structure determination methods. These results demonstrate the value of a universal restraint converter in allowing the use of multiple structure generation methods with the same restraint data for consensus analysis of protein NMR structures and the underlying restraint data.

  13. Clinical decision making on the use of physical restraint in intensive care units

    Directory of Open Access Journals (Sweden)

    Xinqian Li

    2014-12-01

    Full Text Available Physical restraint is a common nursing intervention in intensive care units and nurses often use it to ensure patients' safety and to prevent unexpected accidents. However, existing literature indicated that the use of physical restraint is a complex one because of inadequate rationales, the negative physical and emotional effects on patients, but the lack of perceived alternatives. This paper is aimed to interpret the clinical decision-making theories related to the use of physical restraint in intensive care units in order to facilitate our understanding on the use of physical restraint and to evaluate the quality of decisions made by nurses. By reviewing the literature, intuition and heuristics are the main decision-making strategies related to the use of physical restraint in intensive care units because the rapid and reflexive nature of intuition and heuristics allow nurses to have a rapid response to urgent and emergent cases. However, it is problematic if nurses simply count their decision-making on experience rather than incorporate research evidence into clinical practice because of inadequate evidence to support the use of physical restraint. Besides that, such a rapid response may lead nurses to make decisions without adequate assessment and thinking and therefore biases and errors may be generated. Therefore, despite the importance of intuition and heuristics in decision-making in acute settings on the use of physical restraint, it is recommended that nurses should incorporate research evidence with their experience to make decisions and adequate assessment before implementing physical restraint is also necessary.

  14. Evaluation of Multi Canister Overpack (MCO) Handling Machine Uplift Restraint for a Seismic Event During Repositioning Operations

    International Nuclear Information System (INIS)

    SWENSON, C.E.

    2000-01-01

    Insertion of the Multi-Canister Overpack (MCO) assemblies into the Canister Storage Building (CSB) storage tubes involves the use of the MCO Handling Machine (MHM). During MCO storage tube insertion operations, inadvertent movement of the MHM is prevented by engaging seismic restraints (''active restraints'') located adjacent to both the bridge and trolley wheels. During MHM repositioning operations, the active restraints are not engaged. When the active seismic restraints are not engaged, the only functioning seismic restraints are non-engageable (''passive'') wheel uplift restraints which function only if the wheel uplift is sufficient to close the nominal 0.5-inch gap at the uplift restraint interface. The MHM was designed and analyzed in accordance with ASME NOG-1-1995. The ALSTHOM seismic analysis reported seismic loads on the MHM uplift restraints and EDERER performed corresponding structural calculations to demonstrate structural adequacy of the seismic uplift restraint hardware. The ALSTHOM and EDERER calculations were performed for a parked MHM with the active seismic restraints engaged, resulting in uplift restraint loading only in the vertical direction. In support of development of the CSB Safety Analysis Report (SAR), an evaluation of the MHM seismic response was requested for the case where the active seismic restraints are not engaged. If a seismic event occurs during MHM repositioning operations, a moving contact at a seismic uplift restraint would introduce a friction load on the restraint in the direction of the movement. These potential horizontal friction loads on the uplift restraints were not included in the existing restraint hardware design calculations. One of the purposes of the current evaluation is to address the structural adequacy of the MHM seismic uplift restraints with the addition of the horizontal friction associated with MHM repositioning movements

  15. Use of child restraint system and patterns of child transportation in Riyadh, Saudi Arabia.

    Science.gov (United States)

    Alsanea, Mohammd; Masuadi, Emad; Hazwani, Tarek

    2018-01-01

    Child restraint system (CRS) is designed to protect children from injury during motor vehicle crash (MVC). However, there is no regulation or enforcement of CRS use in Saudi Arabia. This study estimated the prevalence of CRS use and identified patterns of child transportation in Riyadh, Saudi Arabia. In this cross-sectional study, a self-administered questionnaire was distributed across Riyadh targeting families who drove with children aged less than 5 years. The questionnaire inquired about CRS availability, patterns of child transportation if a CRS was unavailable, seat belt use by the driver and adult passengers, and the perception of CRS. Of 385 respondents, only 36.6% reported the availability of a CRS (95% CI: 31.8-41.7%), with only half of those reported consistent use 74 (52.2%). Nearly 30% of all children aged less than 5 years were restrained during car journeys. Sitting on the lap of an adult passenger on the front seat was the most common pattern of child transportation (54.5%). Approximately 13.5% of respondents were involved in an MVC while driving with children; 63.5% of these children were unprotected by any safety system. Seat belt use by drivers was low, with only 15.3% reporting constant use. The prevalence of CRS use in Riyadh is low, and safety practices are seldom used by drivers and passengers. In addition to legal enforcement of CRS use, implementation of a child transportation policy with age-appropriate height and weight specifications is imperative.

  16. The influence of personal protection equipment, occupant body size, and restraint system on the frontal impact responses of Hybrid III ATDs in tactical vehicles.

    Science.gov (United States)

    Zaseck, Lauren Wood; Orton, Nichole Ritchie; Gruber, Rebekah; Rupp, Jonathan; Scherer, Risa; Reed, Matthew; Hu, Jingwen

    2017-08-18

    Although advanced restraint systems, such as seat belt pretensioners and load limiters, can provide improved occupant protection in crashes, such technologies are currently not utilized in military vehicles. The design and use of military vehicles presents unique challenges to occupant safety-including differences in compartment geometry and occupant clothing and gear-that make direct application of optimal civilian restraint systems to military vehicles inappropriate. For military vehicle environments, finite element (FE) modeling can be used to assess various configurations of restraint systems and determine the optimal configuration that minimizes injury risk to the occupant. The models must, however, be validated against physical tests before implementation. The objective of this study was therefore to provide the data necessary for FE model validation by conducting sled tests using anthropomorphic test devices (ATDs). A secondary objective of this test series was to examine the influence of occupant body size (5th percentile female, 50th percentile male, and 95th percentile male), military gear (helmet/vest/tactical assault panels), seat belt type (3-point and 5-point), and advanced seat belt technologies (pretensioner and load limiter) on occupant kinematics and injury risk in frontal crashes. In total, 20 frontal sled tests were conducted using a custom sled buck that was reconfigurable to represent both the driver and passenger compartments of a light tactical military vehicle. Tests were performed at a delta-V of 30 mph and a peak acceleration of 25 g. The sled tests used the Hybrid III 5th percentile female, 50th percentile male, and 95th percentile male ATDs outfitted with standard combat boots and advanced combat helmets. In some tests, the ATDs were outfitted with additional military gear, which included an improved outer tactical vest (IOTV), IOTV and squad automatic weapon (SAW) gunner with a tactical assault panel (TAP), or IOTV and rifleman with

  17. 78 FR 33150 - RECARO Child Safety, LLC, Receipt of Petition for Decision of Inconsequential Noncompliance

    Science.gov (United States)

    2013-06-03

    ...: RECARO Child Safety, LLC (RECARO) \\1\\ has determined that certain RECARO brand ProSport child restraint... RECARO brand ProSport child restraint systems produced between June 16, 2010 and January 31, 2013..., although there is no limit to the length of necessary attachments to the comments. If comments are...

  18. Use of child restraint system and patterns of child transportation in Riyadh, Saudi Arabia.

    Directory of Open Access Journals (Sweden)

    Mohammd Alsanea

    Full Text Available Child restraint system (CRS is designed to protect children from injury during motor vehicle crash (MVC. However, there is no regulation or enforcement of CRS use in Saudi Arabia. This study estimated the prevalence of CRS use and identified patterns of child transportation in Riyadh, Saudi Arabia.In this cross-sectional study, a self-administered questionnaire was distributed across Riyadh targeting families who drove with children aged less than 5 years. The questionnaire inquired about CRS availability, patterns of child transportation if a CRS was unavailable, seat belt use by the driver and adult passengers, and the perception of CRS.Of 385 respondents, only 36.6% reported the availability of a CRS (95% CI: 31.8-41.7%, with only half of those reported consistent use 74 (52.2%. Nearly 30% of all children aged less than 5 years were restrained during car journeys. Sitting on the lap of an adult passenger on the front seat was the most common pattern of child transportation (54.5%. Approximately 13.5% of respondents were involved in an MVC while driving with children; 63.5% of these children were unprotected by any safety system. Seat belt use by drivers was low, with only 15.3% reporting constant use.The prevalence of CRS use in Riyadh is low, and safety practices are seldom used by drivers and passengers. In addition to legal enforcement of CRS use, implementation of a child transportation policy with age-appropriate height and weight specifications is imperative.

  19. Effect of head restraint backset on head-neck kinematics in whiplash.

    Science.gov (United States)

    Stemper, Brian D; Yoganandan, Narayan; Pintar, Frank A

    2006-03-01

    Although head restraints were introduced in the 1960s as a countermeasure for whiplash, their limited effectiveness has been attributed to incorrect positioning. The effect of backset on cervical segmental angulations, which were previously correlated with spinal injury, has not been delineated. Therefore, the practical restraint position to minimize injury remains unclear. A parametric study of increasing head restraint backset between 0 and 140mm was conducted using a comprehensively validated computational model. Head retraction values increased with increasing backset, reaching a maximum value of 53.5mm for backsets greater than 60mm. Segmental angulation magnitudes, greatest at levels C5-C6 and C6-C7, reached maximum values during the retraction phase and increased with increasing backset. Results were compared to a previously published head restraint rating system, wherein lower cervical extension magnitudes from this study exceeded mean physiologic limits for restraint positions rated good, acceptable, marginal, and poor. As head restraint contact was the limiting factor in head retraction and segmental angulations, the present study indicates that minimizing whiplash injury may be accomplished by limiting head restraint backset to less than 60mm either passively or actively after impact.

  20. The usage of crash-safety simulation software in the automotive industry

    NARCIS (Netherlands)

    Verschut, R.; Hyun, Y.W.

    1998-01-01

    The last 10 years the safety issue for road vehicles has become increasingly important. Not only regulations but also NCAP testing force manufacturers to develop restraint systems which can meet the stringent criteria set by these procedures. Because of the various safety requirements the

  1. Effect of honey on the reproductive system of male rat offspring exposed to prenatal restraint stress.

    Science.gov (United States)

    Haron, M N; Mohamed, M

    2016-06-01

    Exposure to prenatal stress is associated with impaired reproductive function in male rat offspring. Honey is traditionally used by the Malays for enhancement of fertility. The aim of this study was to determine the effect of honey on reproductive system of male rat offspring exposed to prenatal restraint stress. Dams were divided into four groups (n = 10/group): control, honey, stress and honey + stress groups. Dams from honey and honey + stress groups received oral honey (1.2 g kg(-1) body weight) daily from day 1 of pregnancy, meanwhile dams from stress and honey + stress groups were subjected to restraint stress (three times per day) from day 11 of pregnancy until delivery. At 10 weeks old, each male rat offspring was mated with a regular oestrus cycle female. Male sexual behaviour and reproductive performance were evaluated. Then, male rats were euthanised for assessment on reproductive parameters. Honey supplementation during prenatal restraint stress significantly increased testis and epididymis weights as well as improved the percentages of abnormal spermatozoa and sperm motility in male rat offspring. In conclusion, this study might suggest that supplementation of honey during pregnancy seems to reduce the adverse effects of restraint stress on reproductive organs weight and sperm parameters in male rat offspring. © 2015 Blackwell Verlag GmbH.

  2. Evaluating a smartphone application to improve child passenger safety and fire safety knowledge and behaviour.

    Science.gov (United States)

    Omaki, Elise; Shields, Wendy C; McDonald, Eileen; Aitken, Mary E; Bishai, David; Case, James; Gielen, Andrea

    2017-02-01

    Although proven measures for reducing injury due to motor vehicle collision and residential fires exist, the number of families properly and consistently using child passenger restraints and smoke alarms remains low. This paper describes the design of the Safety In Seconds (SIS) 2.0 study, which aims to evaluate the impact of a smartphone app on parents' use of child restraints and smoke alarms. SIS is a multisite randomised controlled trial. Participants are parents of children aged 4-7 years who are visiting the Pediatric Emergency Department or Pediatric Trauma Service. Parents are randomised to receive tailored education about child passenger safety or about fire safety via the SIS smartphone app. A baseline and two follow-up surveys at 3 months and 6 months are conducted. Primary outcomes are: (1) having the correct child restraint for the child's age and size; (2) restraining the child in the back seat of the car; (3) buckling the child up for every ride; (4) having the restraint inspected by a child passenger safety technician; (5) having a working smoke alarm on every level of the home; (6) having hard-wired or lithium battery smoke alarms; (7) having and (8) practising a fire escape plan. Finding ways to communicate with parents about child passenger and fire safety continues to be a research priority. This study will contribute to the evidence about how to promote benefits of proper and consistent child restraint and smoke alarm use. NCT02345941; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. 49 CFR 213.110 - Gage restraint measurement systems.

    Science.gov (United States)

    2010-10-01

    ... requirements specified in §§ 213.109 and 213.127. (5) If the PTLF becomes non-functional or is missing, the... and fastener requirements specified in §§ 213.109 and 213.127 provided that— (1) The track owner... the minimum design requirements of a GRMS vehicle which specify that— (1) Gage restraint shall be...

  4. Underutilization of occupant restraint systems in motor vehicle injury crashes: A quantitative analysis from Qatar.

    Science.gov (United States)

    El-Menyar, Ayman; Consunji, Rafael; Asim, Mohammad; Abdelrahman, Husham; Zarour, Ahmad; Parchani, Ashok; Peralta, Ruben; Al-Thani, Hassan

    2016-01-01

    Restraint systems (seat belts and airbags) are important tools that improve vehicle occupant safety during motor vehicle crashes (MVCs). We aimed to identify the pattern and impact of the utilization of passenger restraint systems on the outcomes of MVC victims in Qatar. A retrospective study was conducted for all admitted patients who sustained MVC-related injuries between March 2011 and March 2014 inclusive. Out of 2,730 road traffic injury cases, 1,830 (67%) sustained MVC-related injuries, of whom 88% were young males, 70% were expatriates, and 53% were drivers. The use of seat belts and airbags was documented in 26 and 2.5% of cases, respectively. Unrestrained passengers had greater injury severity scores, longer hospital stays, and higher rates of pneumonia and mortality compared to restrained passengers (P = .001 for all). There were 311 (17%) ejected cases. Seat belt use was significantly lower and the mortality rate was 3-fold higher in the ejected group compared to the nonejected group (P = .001). The overall mortality was 8.3%. On multivariate regression analysis, predictors of not using a seat belt were being a front seat passenger, driver, or Qatari national and young age. Unrestrained males had a 3-fold increase in mortality in comparison to unrestrained females. The risk of severe injury (relative risk [RR] = 1.82, 95% confidence interval [CI], 1.49-2.26, P = .001) and death (RR = 4.13, 95% CI, 2.31-7.38, P = .001) was significantly greater among unrestrained passengers. The nonuse of seat belts is associated with worse outcomes during MVCs in Qatar. Our study highlights the lower rate of seat belt compliance in young car occupants that results in more severe injuries, longer hospital stays, and higher mortality rates. Therefore, we recommend more effective seat belt awareness and education campaigns, the enforcement of current seat belt laws, their extension to all vehicle occupants, and the adoption of proven interventions that will assure sustained

  5. Restraint methods for radiography in dogs and cats

    International Nuclear Information System (INIS)

    Scrivani, P.V.; Bednarski, R.M.; Myer, C.W.; Dykes, N.L.

    1996-01-01

    Excellent patient restraint techniques are necessary to produce high-quality diagnostic images during survey and contrast radiography and ultrasonography. Use of non manual physical restraint (i.e., devices to hold the patient in position) helps reduce the exposure of veterinary personnel to radiation. Exposure of personnel to radiation should be kept as low as reasonably achievable. Usually, this involves taking the radiograph when no personnel are present in the room. Some procedures, however, require the presence of the veterinarian. No personnel should ever put any part of their bodies in the path of the x-ray beam. Protective gear must be worn. Physical restraint can be facilitated by chemical restraint, which varies from minimal sedation to general anesthesia. Appropriate chemical restraint for radiography is the minimum amount of sedation required for the efficient and safe completion of the radiographic examination. Chemical restraint techniques vary according to the patient's physical status, the type of examination, and the skill of the examiner in non manual restraint techniques. This article describes techniques for non manual restraint and protocols for chemical restraint for dogs and cats

  6. Conceptual design of pipe whip restraints using interactive computer analysis

    International Nuclear Information System (INIS)

    Rigamonti, G.; Dainora, J.

    1975-01-01

    Protection against pipe break effects necessitates a complex interaction between failure mode analysis, piping layout, and structural design. Many iterations are required to finalize structural designs and equipment arrangements. The magnitude of the pipe break loads transmitted by the pipe whip restraints to structural embedments precludes the application of conservative design margins. A simplified analytical formulation of the nonlinear dynamic problems associated with pipe whip has been developed and applied using interactive computer analysis techniques. In the dynamic analysis, the restraint and the associated portion of the piping system, are modeled using the finite element lumped mass approach to properly reflect the dynamic characteristics of the piping/restraint system. The analysis is performed as a series of piecewise linear increments. Each of these linear increments is terminated by either formation of plastic conditions or closing/opening of gaps. The stiffness matrix is modified to reflect the changed stiffness characteristics of the system and re-started using the previous boundary conditions. The formation of yield hinges are related to the plastic moment of the section and unloading paths are automatically considered. The conceptual design of the piping/restraint system is performed using interactive computer analysis. The application of the simplified analytical approach with interactive computer analysis results in an order of magnitude reduction in engineering time and computer cost. (Auth.)

  7. Anticipatory precrash restraint sensor feasibility study: Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kercel, S.W.; Dress, W.B.

    1995-08-01

    This report explores feasibility of an anticipatory precrash restraint sensor. The foundation principle is the anticipation mechanism found at a primitive level of biological intelligence and originally formalized by the mathematical biologist Robert Rosen. A system based on formal anticipatory principles should significantly outperform conventional technologies. It offers the prospect of high payoff in prevention of death and injury. Sensors and processes are available to provide a good, fast, and inexpensive description of the present dynamical state of the vehicle to the embedded system model in the anticipation engine. The experimental part of this study found that inexpensive radar in a real-world setting does return useful data on target dynamics. The data produced by a radar system can be converted to target dynamical information by good, fast and inexpensive signal-processing techniques. Not only is the anticipatory sensor feasible, but further development under the sponsorship of the National Highway Traffic Safety Administration is necessary and desirable. There are a number of possible lines of follow-on investigation. The level of effort and expected benefits of various alternatives are discussed.

  8. Child restraint use in low socio-economic areas of urban Sydney during transition to new legislation.

    Science.gov (United States)

    Keay, Lisa; Hunter, Kate; Brown, Julie; Bilston, Lynne E; Simpson, Judy M; Stevenson, Mark; Ivers, Rebecca Q

    2013-01-01

    Child restraints protect a young child against injury in crashes but best practice child restraint use is low in Australia, particularly among lower socio-economic groups. We investigated factors associated with restraint use to inform the development of education and distribution programmes to support new Australian legislation on child passengers among families in low socio-economic areas of metropolitan Sydney. We interviewed a parent or carer of 1160 children aged 2-5 years enrolled at one of 28 early childhood centres in low socio-economic areas of urban Sydney. Appropriate child restraint use was defined as a forward facing child restraint (FFCR) for 2-3 year olds and a FFCR or booster seat for children aged 4 years or more. Predictors of self-reported appropriate use were explored using logistic regression. Analysis was conducted on one child from each family in the target age range (2-5 years): 586 (51%) were male and the mean age was 3.5 (Standard Deviation 0.8) years. There were 432 (45%) families with annual income below $60,000, 248 (22%) spoke a language other than English at home and 360 (33%) had 3 or more children. Fifty-four percent of carers indicated that their 2-3 year old children travelled in a FFCR. Inappropriate use among children in this age group was more likely when the carer was law and poorer knowledge of safety benefits of child restraints. They also had lower household incomes and more concerns about cost of child restraints and booster seats. These findings can inform development of interventions to promote best practice child restraint use, which will reach non-English speaking families in this region. They also confirm the importance of economic and logistic barriers to best practice child restraint use. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Effects and costs of requiring child-restraint systems for young children traveling on commercial airplanes.

    Science.gov (United States)

    Newman, Thomas B; Johnston, Brian D; Grossman, David C

    2003-10-01

    The US Federal Aviation Administration is planning a new regulation requiring children younger than 2 years to ride in approved child-restraint seats on airplanes. To estimate the annual number of child air crash deaths that might be prevented by the proposed regulation, the threshold proportion of families switching from air to car travel above which the risks of the policy would exceed its benefits, and the cost per death prevented. Risk and economic analyses. Child-restraint seat use could prevent about 0.4 child air crash deaths per year in the United States. Increased deaths as a result of car travel could exceed deaths prevented by restraint seat use if the proportion of families switching from air to car travel exceeded about 5% to 10%. The estimate for this proportion varied with assumptions about trip distance, driver characteristics, and the effectiveness of child-restraint seats but is unlikely to exceed 15%. Assuming no increase in car travel, for each dollar increase in the cost of implementing the regulation per round trip per family, the cost per death prevented would increase by about $6.4 million. Unless space for young children in restraint seats can be provided at low cost to families, with little or no diversion to automobile travel, a policy requiring restraint seat use could cause a net increase in deaths. Even excluding this possibility, the cost of the proposed policy per death prevented is high.

  10. [Analysis on influencing factors for child restraint system use in Shanghai and Shenzhen, China].

    Science.gov (United States)

    Deng, Xiao; Jin, Ye; Peng, Ji; Xia, Qinghua; Ma, Jianping; Wang, Linhong; Duan, Leilei

    2016-01-01

    To understand the factors related with child restraint system (CRS) use, and provide evidence for the development of appropriate intervention measures to promote the use of CRS for the protection of child passengers' safety. Self-administrated questionnaire survey was conducted among 0-6 years old children's parents who owned private cars selected through stratified cluster random sampling in Shanghai and Shenzhen to collect date about CRS use and related factors. Group discussion was conducted among some of the parents randomly selected to further understand the reasons for using or not using CRS. Of 7528 parents surveyed, 39.23% (2820/7189) reported to have CRS and 17.14% (1232/7189) reported consistent use of CRS. Multivariate analysis indicated that young age of children, high level of education of parents, good family economic status, awareness of importance of children's safety were the positive factors for CRS use. The frequency and distance of children'car taking and the seatbelt use of drivers significantly influenced the CRS use. The main reasons for not purchasing CRS included limited car space (53.33%, 2329/4 367), low frequency of children car taking (48.55%, 2120/4367), difficulty in installation (42.25%, 1845/4367), high cost (38.58%, 1685/4367), and unreliable quality (31.03%, 1355/4367). The main reasons for not using CRS included children's refusal (67.36%, 293/435), short travel distance (53.79%, 234/435), difficulty in installation or use (53.10%, 231/435), limited car space (32.41%, 141/435), and unnecessary (25.75%, 112/435). Parents have gaps and misunderstandings in using CRSs to protect child passengers safety. There are demands of technical guiding service in use of CRS. Integrated intervention measures should be implemented targeting at the identified barriers and needs in CRS use to promote child passenger safety, which include strengthening the propaganda and education, promoting the legislation and law enforcement, strengthening market

  11. Gas-Induced Water-hammer Loads Calculation for Safety Related Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seungchan; Yoon, Dukjoo [Korea Hydro and Nuclear Power Co., LTd, Daejeon (Korea, Republic of); Lee, Dooyong [Seoul National Univ., Seoul (Korea, Republic of)

    2013-05-15

    Of particular interest, gas accumulation can result in system pressure transient in pump discharge piping following a pump start. Consequently, this evolves into a gas-water, a water-hammer event and the accompanying force imbalances on the piping segments can be sufficient to challenge the piping supports and restraint. This paper describes an method performing to the water-hammer loads to determine the maximum loading that would occur in the piping system following the safety injection signal and to evaluate its integrity. For a given gas void volumes in the discharge piping, the result of the calculation shows the maximum loads of 18,894.2psi, which is smaller than the allowable criteria. Also, the maximum peak axial force imbalances acting on the support is 1,720lbf as above.

  12. Gas-Induced Water-hammer Loads Calculation for Safety Related Systems

    International Nuclear Information System (INIS)

    Lee, Seungchan; Yoon, Dukjoo; Lee, Dooyong

    2013-01-01

    Of particular interest, gas accumulation can result in system pressure transient in pump discharge piping following a pump start. Consequently, this evolves into a gas-water, a water-hammer event and the accompanying force imbalances on the piping segments can be sufficient to challenge the piping supports and restraint. This paper describes an method performing to the water-hammer loads to determine the maximum loading that would occur in the piping system following the safety injection signal and to evaluate its integrity. For a given gas void volumes in the discharge piping, the result of the calculation shows the maximum loads of 18,894.2psi, which is smaller than the allowable criteria. Also, the maximum peak axial force imbalances acting on the support is 1,720lbf as above

  13. Measurement of Dietary Restraint: Validity Tests of Four Questionnaires

    Science.gov (United States)

    Williamson, Donald A.; Martin, Corby K.; York-Crowe, Emily; Anton, Stephen D.; Redman, Leanne M.; Han, Hongmei; Ravussin, Eric

    2007-01-01

    This study tested the validity of four measures of dietary restraint: Dutch Eating Behavior Questionnaire, Eating Inventory (EI), Revised Restraint Scale (RS), and the Current Dieting Questionnaire. Dietary restraint has been implicated as a determinant of overeating and binge eating. Conflicting findings have been attributed to different methods for measuring dietary restraint. The validity of four self-report measures of dietary restraint and dieting behavior was tested using: 1) factor analysis, 2) changes in dietary restraint in a randomized controlled trial of different methods to achieve calorie restriction, and 3) correlation of changes in dietary restraint with an objective measure of energy balance, calculated from the changes in fat mass and fat-free mass over a six-month dietary intervention. Scores from all four questionnaires, measured at baseline, formed a dietary restraint factor, but the RS also loaded on a binge eating factor. Based on change scores, the EI Restraint scale was the only measure that correlated significantly with energy balance expressed as a percentage of energy require d for weight maintenance. These findings suggest that that, of the four questionnaires tested, the EI Restraint scale was the most valid measure of the intent to diet and actual caloric restriction. PMID:17101191

  14. International Space Station Crew Restraint Design

    Science.gov (United States)

    Whitmore, M.; Norris, L.; Holden, K.

    2005-01-01

    With permanent human presence onboard the International Space Station (ISS), crews will be living and working in microgravity, dealing with the challenges of a weightless environment. In addition, the confined nature of the spacecraft environment results in ergonomic challenges such as limited visibility and access to the activity areas, as well as prolonged periods of unnatural postures. Without optimum restraints, crewmembers may be handicapped for performing some of the on-orbit tasks. Currently, many of the tasks on ISS are performed with the crew restrained merely by hooking their arms or toes around handrails to steady themselves. This is adequate for some tasks, but not all. There have been some reports of discomfort/calluses on the top of the toes. In addition, this type of restraint is simply insufficient for tasks that require a large degree of stability. Glovebox design is a good example of a confined workstation concept requiring stability for successful use. They are widely used in industry, university, and government laboratories, as well as in the space environment, and are known to cause postural limitations and visual restrictions. Although there are numerous guidelines pertaining to ventilation, seals, and glove attachment, most of the data have been gathered in a 1-g environment, or are from studies that were conducted prior to the early 1980 s. Little is known about how best to restrain a crewmember using a glovebox in microgravity. In 2004, The Usability Testing and Analysis Facility (UTAF) at the NASA Johnson Space Center completed development/evaluation of several design concepts for crew restraints to meet the various needs outlined above. Restraints were designed for general purpose use, for teleoperation (Robonaut) and for use with the Life Sciences Glovebox. All design efforts followed a human factors engineering design lifecycle, beginning with identification of requirements followed by an iterative prototype/test cycle. Anthropometric

  15. M.E.366-J embodiment design project: Portable foot restraint

    Science.gov (United States)

    Heaton, Randall; Meyer, Eikar; Schmidt, Davey; Enders, Kevin

    1994-01-01

    During space shuttle operations, astronauts require support to carry out tasks in the weightless environment. In the past, portable foot restraints (PFR) with orientations adjustable in pitch, roll, and yaw provided this support for payload bay operations. These foot restraints, however, were designed for specific tasks with a load limit of 111.2 Newtons. Since the original design, new applications for foot restraints have been identified. New designs for the foot restraints have been created to boost the operational work load to 444.8 Newtons and decrease setup times. What remains to be designed is an interface between the restraint system and the extravehicular mobility unit (EMU) boots. NASA provided a proposed locking device involving a spring-loaded mechanism. This locking mechanism must withstand loads of 1334.4 Newtons in any direction and weigh less than 222.4 Newtons. This paper develops an embodiment design for the interface between the PFR and the EMU boots. This involves design of the locking mechanism and a removable cleat that allows the boot to interface with this mechanism. The design team used the Paul Beitz engineering methodology to present the systematic development, structural analysis, and production considerations of the embodiment design. This methodology provides a basis for understanding the justification behind the decisions made in the design.

  16. Discordance between age- and size-based criteria of child passenger restraint appropriateness.

    Science.gov (United States)

    Smiley, Mary L; Bingham, C Raymond; Jacobson, Peter D; Macy, Michelle L

    2018-04-03

    In this study, we sought to accomplish the following objectives: to (1) calculate the percentage of children considered appropriately restrained across 8 criteria of increasing restrictiveness; (2) examine agreement between age- and size-based appropriateness criteria; (3) assess for changes in the percentage of children considered appropriately restrained by the 8 criteria between 2011 (shortly after updates to U.S. guidelines) and 2015. Data from 2 cross-sectional surveys of 928 parents of children younger than 12 years old (n = 591 in 2011, n = 337 in 2015) were analyzed in 2017. Child age, weight, and height were measured at an emergency department visit and used to determine whether the parent-reported child passenger restraint was considered appropriate according to 8 criteria. Age-based criteria were derived from Michigan law and U.S. Weight, height, and size-based criteria were derived from typical restraints available in the United States in 2007 and 2011. The percentage appropriate restraint use was calculated for each criterion. The kappa statistic was used to measure agreement between criteria. Change in appropriateness from 2011 to 2015 was assessed with chi-square statistics. Percentage appropriate restraint use varied from a low of 19% for higher weight limits in 2011 to a high of 91% for Michigan law in 2015. Agreement between criteria was slight to moderate. The lowest kappa was for Michigan law and higher weight limits in 2011 (κ = 0.06) and highest for U.S. guidelines and lower weight limits in 2011 (κ = 0.60). Percentage appropriate restraint use was higher in 2015 than 2011 for the following criteria: U.S. guidelines (74 vs. 58%, P consistency in reporting results from studies of child passenger safety in the United States. Potential explanations for the increased percentage of children considered appropriately restrained between 2011 and 2015 include adoption of the updated U.S. guidelines and the use of child passenger restraints with

  17. Restraint, tendency toward overeating and ice cream consumption

    NARCIS (Netherlands)

    Van Strien, T; Cleven, A.H.G.; Schippers, G.

    2000-01-01

    OBJECTIVE: The examination of the prediction of grams of ice cream eaten by preload, restraint, susceptibility toward overeating, and interaction terms. METHOD: A milkshake-ice cream study on 200 females using the Restraint Scale (RS) and the restraint and disinhibition scales from the Three-Factor

  18. Real-time adjustment of ventricular restraint therapy in heart failure.

    Science.gov (United States)

    Ghanta, Ravi K; Lee, Lawrence S; Umakanthan, Ramanan; Laurence, Rita G; Fox, John A; Bolman, Ralph Morton; Cohn, Lawrence H; Chen, Frederick Y

    2008-12-01

    Current ventricular restraint devices do not allow for either the measurement or adjustment of ventricular restraint level. Periodic adjustment of restraint level post-device implantation may improve therapeutic efficacy. We evaluated the feasibility of an adjustable quantitative ventricular restraint (QVR) technique utilizing a fluid-filled polyurethane epicardial balloon to measure and adjust restraint level post-implantation guided by physiologic parameters. QVR balloons were implanted in nine ovine with post-infarction dilated heart failure. Restraint level was defined by the maximum restraint pressure applied by the balloon to the epicardium at end-diastole. An access line connected the balloon lumen to a subcutaneous portacath to allow percutaneous access. Restraint level was adjusted while left ventricular (LV) end-diastolic volume (EDV) and cardiac output was assessed with simultaneous transthoracic echocardiography. All nine ovine successfully underwent QVR balloon implantation. Post-implantation, restraint level could be measured percutaneously in real-time and dynamically adjusted by instillation and withdrawal of fluid from the balloon lumen. Using simultaneous echocardiography, restraint level could be adjusted based on LV EDV and cardiac output. After QVR therapy for 21 days, LV EDV decreased from 133+/-15 ml to 113+/-17 ml (p<0.05). QVR permits real-time measurement and physiologic adjustment of ventricular restraint therapy after device implantation.

  19. Astronaut Anna Fisher demonstrates sleep restraints on shuttle

    Science.gov (United States)

    1984-01-01

    Astronaut Anna L. Fisher demonstrates the versatility of shuttle sleep restraints to accommodate the preference of crewmembers as she appears to have configured hers in a horizontal hammock mode. Stowage lockers, one of the middeck walls, another sleep restraint, a jury-rigged foot and hand restraint are among other items in the frame.

  20. Depletion of norepinephrine of the central nervous system Down-regulates the blood glucose level in d-glucose-fed and restraint stress models.

    Science.gov (United States)

    Park, Soo-Hyun; Kim, Sung-Su; Lee, Jae-Ryeong; Sharma, Naveen; Suh, Hong-Won

    2016-05-04

    DSP-4[N-(2-chloroethyl)-N-ethyl-2-bromobenzylamine hydrochloride] is a neurotoxin that depletes norepinephrine. The catecholaminergic system has been implicated in the regulation of blood glucose level. In the present study, the effect of DSP-4 administered intracerebroventricularly (i.c.v.) or intrathecally (i.t.) on blood glucose level was examined in d-glucose-fed and restraint stress mice models. Mice were pretreated once i.c.v. or i.t. with DSP-4 (10-40μg) for 3days, and d-glucose (2g/kg) was fed orally. Blood glucose level was measured 0 (prior to glucose feeding or restraint stress), 30, 60, and 120min after d-glucose feeding or restraint stress. The i.c.v. or i.t. pretreatment with DSP-4 attenuated blood glucose level in the d-glucose-fed model. Plasma corticosterone level was downregulated in the d-glucose-fed model, whereas plasma insulin level increased in the d-glucose-fed group. The i.c.v. or i.t. pretreatment with DSP-4 reversed the downregulation of plasma corticosterone induced by feeding d-glucose. In addition, the d-glucose-induced increase in plasma insulin was attenuated by the DSP-4 pretreatment. Furthermore, i.c.v. or i.t. pretreatment with DSP-4 reduced restraint stress-induced increases in blood glucose levels. Restraint stress increased plasma corticosterone and insulin levels. The i.c.v. pretreatment with DSP-4 attenuated restraint stress-induced plasma corticosterone and insulin levels. Our results suggest that depleting norepinephrine at the supraspinal and spinal levels appears to be responsible for downregulating blood glucose levels in both d-glucose-fed and restraint stress models. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Restraint use law enforcement intervention in Latino communities.

    Science.gov (United States)

    Schaechter, Judy; Uhlhorn, Susan B

    2011-11-01

    Motor vehicle crashes are the leading cause of death for U.S. Latinos aged 1 to 35 years. Restraint use is an effective means of prevention of motor vehicle crash injury. Effective interventions to raise restraint use include the following: legislation, law enforcement, education, and equipment distribution. The effects of law enforcement interventions in Latino immigrant communities are understudied. We measured the community-level effect of a combined intervention that included warnings and citations phase enforcement in Latino communities. We designed and implemented in two of three Latino-majority communities a multicomponent intervention consisting of a community awareness campaign, restraint use education with equipment distribution, and a two-staged law enforcement intervention. Restraint use observations were conducted in all three communities at baseline, after the warnings phase and again after the citations phase of the intervention were completed. The combined intervention of community awareness, education, child passenger restraint distribution, and law enforcement focused on educational traffic stops with incentives and warnings was associated with a significant increase in both driver and child passenger restraint use in one intervention community, but only driver restraint increased to a level of significance in the other intervention community; significant increase was also noted among nonintervention drivers. The citations phase of the intervention did not result in a significant increase in restraint use and was complicated by interruptions due to unlicensed drivers. The combined effort of community awareness, education, equipment distribution and law enforcement intervention that included incentives and warnings may be effective at increasing seat belt use in Latino communities without the need for citations.

  2. Designing and evaluating a persuasive child restraint television commercial.

    Science.gov (United States)

    Lewis, Ioni; Ho, Bonnie; Lennon, Alexia

    2016-01-01

    Relatively high rates of child restraint inappropriate use and misuse and faults in the installation of restraints have suggested a crucial need for public education messages to raise parental awareness of the need to use restraints correctly. This project involved the devising and pilot testing of message concepts, filming of a television advertisement (the TVC), and the evaluation of the TVC. This article focuses specifically upon the evaluation of the TVC. The development and evaluation of the TVC were guided by an extended theory of planned behavior that included the standard constructs of attitudes, subjective norms, and perceived behavioral control as well as the additional constructs of group norms and descriptive norms. The study also explored the extent to which parents with low and high intentions to self-check restraints differed on salient beliefs regarding the behavior. An online survey of parents (N = 384) was conducted where parents were randomly assigned to either the intervention group (n = 161), and therefore viewed the advertisement within the survey, or the control group (n = 223), and therefore did not view the advertisement. Following a one-off exposure to the TVC, the results indicated that, although not a significant difference, parents in the intervention group reported stronger intentions (M = 4.43, SD = 0.74) to self-check restraints than parents in the control group (M = 4.18, SD = 0.86). In addition, parents in the intervention group (M = 4.59, SD = 0.47) reported significantly higher levels of perceived behavioral control than parents in the control group (M = 4.40, SD = 0.73). The regression results revealed that, for parents in the intervention group, attitudes and group norms were significant predictors of parental intentions to self-check their child restraint. Finally, the exploratory analyses of parental beliefs suggested that those parents with low intentions to self-check child restraints were significantly more likely than

  3. A mixed-methods systematic review protocol to examine the use of physical restraint with critically ill adults and strategies for minimizing their use.

    Science.gov (United States)

    Rose, Louise; Dale, Craig; Smith, Orla M; Burry, Lisa; Enright, Glenn; Fergusson, Dean; Sinha, Samir; Wiesenfeld, Lesley; Sinuff, Tasnim; Mehta, Sangeeta

    2016-11-21

    Critically ill patients frequently experience severe agitation placing them at risk of harm. Physical restraint is common in intensive care units (ICUs) for clinician concerns about safety. However, physical restraint may not prevent medical device removal and has been associated with negative physical and psychological consequences. While professional society guidelines, legislation, and accreditation standards recommend physical restraint minimization, guidelines for critically ill patients are over a decade old, with recommendations that are non-specific. Our systematic review will synthesize evidence on physical restraint in critically ill adults with the primary objective of identifying effective minimization strategies. Two authors will independently search from inception to July 2016 the following: Ovid MEDLINE, CINAHL, Embase, Web of Science, Cochrane Library, PROSPERO, Joanna Briggs Institute, grey literature, professional society websites, and the International Clinical Trials Registry Platform. We will include quantitative and qualitative study designs, clinical practice guidelines, policy documents, and professional society recommendations relevant to physical restraint of critically ill adults. Authors will independently perform data extraction in duplicate and complete risk of bias and quality assessment using recommended tools. We will assess evidence quality for quantitative studies using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach and for qualitative studies using the Confidence in the Evidence from Reviews of Qualitative Research (CERQual) guidelines. Outcomes of interest include (1) efficacy/effectiveness of physical restraint minimization strategies; (2) adverse events (unintentional device removal, psychological impact, physical injury) and associated benefits including harm prevention; (3) ICU outcomes (ventilation duration, length of stay, and mortality); (4) prevalence, incidence, patterns of use

  4. A mixed-methods systematic review protocol to examine the use of physical restraint with critically ill adults and strategies for minimizing their use

    Directory of Open Access Journals (Sweden)

    Louise Rose

    2016-11-01

    Full Text Available Abstract Background Critically ill patients frequently experience severe agitation placing them at risk of harm. Physical restraint is common in intensive care units (ICUs for clinician concerns about safety. However, physical restraint may not prevent medical device removal and has been associated with negative physical and psychological consequences. While professional society guidelines, legislation, and accreditation standards recommend physical restraint minimization, guidelines for critically ill patients are over a decade old, with recommendations that are non-specific. Our systematic review will synthesize evidence on physical restraint in critically ill adults with the primary objective of identifying effective minimization strategies. Methods Two authors will independently search from inception to July 2016 the following: Ovid MEDLINE, CINAHL, Embase, Web of Science, Cochrane Library, PROSPERO, Joanna Briggs Institute, grey literature, professional society websites, and the International Clinical Trials Registry Platform. We will include quantitative and qualitative study designs, clinical practice guidelines, policy documents, and professional society recommendations relevant to physical restraint of critically ill adults. Authors will independently perform data extraction in duplicate and complete risk of bias and quality assessment using recommended tools. We will assess evidence quality for quantitative studies using the Grading of Recommendations Assessment, Development and Evaluation (GRADE approach and for qualitative studies using the Confidence in the Evidence from Reviews of Qualitative Research (CERQual guidelines. Outcomes of interest include (1 efficacy/effectiveness of physical restraint minimization strategies; (2 adverse events (unintentional device removal, psychological impact, physical injury and associated benefits including harm prevention; (3 ICU outcomes (ventilation duration, length of stay, and mortality; (4

  5. Parental practice of child car safety in Enugu, Southeast Nigeria.

    Science.gov (United States)

    Ndu, K I; Ekwochi, U; Osuorah, D C; Ifediora, O C; Amadi, F O; Asinobi, I N; Okenwa, O W; Orjioke, J C; Ogbuka, F N; Ulasi, T O

    2016-01-01

    Child safety restraints and seat belts are regarded as the most successful safety and cost-effective protective devices available to vehicle occupants, which have saved millions of lives. This cross-sectional descriptive study evaluated the practice and use of child car restraints (CCRs) among 458 purposively selected respondents resident in two local government areas in Enugu State, Nigeria. Self-administered questionnaires were sent to parents of children attending private schools who owned a car. Chi-square and multivariate analyses were used to assess the determinants of the use of car restraints in children among respondents. In all, 56% and 45% of adults and children, respectively, used car restraints regularly. The awareness of child safety laws and actual use of age-appropriate CCRs among respondents was negatively and weakly correlated ( r =-0.121, P =0.310). Only respondent's use of seat belt during driving ( P =0.001) and having being cautioned for non-use of CCRs ( P =0.005) maintained significance as determinants of the use of CCRs in cars on multivariate analysis. The most frequent reasons given for the non-use of CCRs included the child being uncomfortable, 64 (31%); restraints not being important, 53 (26%), and restraints being too expensive, 32 (15%). Similarly, for irregular users, exceptions for non-use included the child being asleep (29%), inadequate number of CCRs (22%), and the child being sick (18%). There is a need for a strategy change to enforce the use of CCRs in Nigeria.

  6. Chronic restraint stress in rats causes sustained increase in urinary corticosterone excretion without affecting cerebral or systemic oxidatively generated DNA/RNA damage

    DEFF Research Database (Denmark)

    Jorgensen, Anders; Maigaard, Katrine; Wörtwein, Gitta

    2013-01-01

    acids, 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodG) and 8-oxo-7,8-dihydroguanosine (8-oxoGuo), respectively, in rats subjected to chronic restraint stress. To reliably collect 24h urine samples, the full 3-week restraint stress paradigm was performed in metabolism cages. We further determined frontal...... and Tnf). The metabolism cage housing in itself did not significantly influence a range of biological stress markers. In the restraint stress group, there was a sustained 2.5 fold increase in 24h corticosterone excretion from day 2 after stress initiation. However, neither whole-body nor cerebral measures......Increased oxidatively generated damage to nucleic acids (DNA/RNA) may be a common mechanism underlying accelerated aging in psychological stress states and mental disorders. In the present study, we measured the urinary excretion of corticosterone and markers of systemic oxidative stress on nucleic...

  7. Using in-depth investigations to identify transportation safety issues for wheelchair-seated occupants of motor vehicles.

    Science.gov (United States)

    Schneider, Lawrence W; Klinich, Kathleen D; Moore, Jamie L; MacWilliams, Joel B

    2010-04-01

    In-depth investigations of motor-vehicle crashes involve detailed inspection, measurement, and photodocumentation of vehicle exterior and interior damage, evidence of belt-restraint use, and evidence of occupant contacts with the vehicle interior. Results of in-depth investigations thereby provide the most objective way to identify current and emerging injury problems and issues in occupant safety and crash protection, and provide important feedback on the real-world performance of the latest restraint-system and vehicle crashworthiness technologies. To provide an objective understanding of real-world transportation safety issues for wheelchair-seated travelers, the University of Michigan Transportation Research Institute (UMTRI) has been conducting and assembling data from in-depth investigations of motor-vehicle crashes and non-crash adverse moving-vehicle incidents, such as emergency vehicle braking, turning, and swerving, in which there was at least one vehicle occupant sitting in a wheelchair. The results of 39 investigations involving 42 wheelchair-seated occupants have been assembled and entered into a wheelchair-occupant crash/injury database. In addition, a biomechanical analysis of each case has been performed to identify key safety issues for wheelchair-seated travelers. The wheelchairs of 34 of the 42 occupants who were seated in wheelchairs while traveling in motor vehicles were effectively secured by either a four-point, strap-type tiedown system or a docking securement device, and all but one of these properly secured wheelchairs remained in place during the crash or non-collision event. However, 30 of the 42 occupants were improperly restrained, either because of non-use or incomplete use of available belt restraints, or because the belt restraints were improperly positioned on the occupant's body. Twenty-six of the 42 occupants sustained significant injuries and 10 of these occupants died as a direct result of injuries sustained, or from

  8. Moderation: an alternative to restraint as a mode of weight self-regulation.

    Science.gov (United States)

    Stotland, S

    2012-12-01

    This study considered two types of eating and weight self-regulation, in five groups, including four types of weight controllers and one non-dieting group. New scales were developed to measure eating moderation and restraint. Moderation was largely uncorrelated with restraint in 4 groups and had a fairly strong positive relation in 1 group. The moderation scale was unrelated to the Dutch Eating Behavior Questionnaire (DEBQ) restraint scale and the Three Factor Eating Questionnaire (TFEQ) rigid restraint subscale and weakly positively related to TFEQ flexible restraint. The restraint scale was strongly correlated to the DEBQ restraint scale, and to both flexible and rigid restraint subscales of the TFEQ. Across the five groups, moderation had exclusively positive relationships with attitude, behavior and emotion variables, while restraint had primarily negative relationships. The study supports moderation as a new dimension of weight self-regulation, independent of restraint. The new measures of moderation and restraint can be used together in research on the processes of change in weight management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. Parental practice of child car safety in Enugu, Southeast Nigeria

    Directory of Open Access Journals (Sweden)

    Ndu KI

    2016-11-01

    Full Text Available KI Ndu,1,* U Ekwochi,1,* DC Osuorah,2,* OC Ifediora,3 FO Amadi,1 IN Asinobi,1 OW Okenwa,1 JC Orjioke,1 FN Ogbuka,1 TO Ulasi4 1Department of Paediatrics, Enugu State University of Science and Technology, Enugu State, Engu, Nigeria; 2Child Survival Unit, Medical Research Council UK, The Gambia Unit, Fajara, Gambia; 3Griffiths University Medical School, Gold Coast, QLD, Australia; 4Department of Paediatrics, Nnamdi Azikiwe University Teaching Hospital, Nnewi, Anambra State, Nigeria *These authors contributed equally to this work Abstract: Child safety restraints and seat belts are regarded as the most successful safety and cost-effective protective devices available to vehicle occupants, which have saved millions of lives. This cross-sectional descriptive study evaluated the practice and use of child car restraints (CCRs among 458 purposively selected respondents resident in two local government areas in Enugu State, Nigeria. Self-administered questionnaires were sent to parents of children attending private schools who owned a car. Chi-square and multivariate analyses were used to assess the determinants of the use of car restraints in children among respondents. In all, 56% and 45% of adults and children, respectively, used car restraints regularly. The awareness of child safety laws and actual use of age-appropriate CCRs among respondents was negatively and weakly correlated (r=–0.121, P=0.310. Only respondent’s use of seat belt during driving (P=0.001 and having being cautioned for non-use of CCRs (P=0.005 maintained significance as determinants of the use of CCRs in cars on multivariate analysis. The most frequent reasons given for the non-use of CCRs included the child being uncomfortable, 64 (31%; restraints not being important, 53 (26%, and restraints being too expensive, 32 (15%. Similarly, for irregular users, exceptions for non-use included the child being asleep (29%, inadequate number of CCRs (22%, and the child being sick (18

  10. Sedation and physiologic response to manual restraint after intranasal administration of midazolam in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Mans, Christoph; Guzman, David Sanchez-Migallon; Lahner, Lesanna L; Paul-Murphy, Joanne; Sladky, Kurt K

    2012-09-01

    Administration of intranasal midazolam (2 mg/kg) was evaluated for sedation and effects on cloacal temperature, respiratory rate, and heart rate in manually restrained Hispaniolan Amazon parrots (Amazona ventralis). Adult parrots (n=9) were administered either midazolam (2 mg/kg) or an equal volume of saline solution intranasally before a 15-minute manual restraint in a complete crossover study. Respiratory rate and sedation scores were recorded before and during capture and during and after 15 minutes of manual restraint. Heart rate and cloacal temperature were recorded during manual restraint. After restraint, the parrots received intranasal flumazenil (0.05 mg/kg) or an equal volume of saline solution, and the recovery time was recorded. In those birds that received midazolam, sedation was observed within 3 minutes of administration, and vocalization, flight, and defense responses were significantly reduced during capture. During manual restraint, the mean rate of cloacal temperature increase was significantly slower and remained significantly lower in birds that received midazolam compared with controls. Mean respiratory rates were significantly lower for up to 12 minutes in parrots that received midazolam compared with those receiving saline solution. Flumazenil antagonized the effects of midazolam within 10 minutes. No overt clinical adverse effects to intranasal midazolam and flumazenil administration were observed. Further studies on the safety of intranasal midazolam and flumazenil in this species are warranted.

  11. Securing the safety of our most precious cargo: SAFE KIDS.

    Science.gov (United States)

    Vick, Judith W

    2010-01-01

    There are staggering and tragic statistics involving children, car seats, and motor vehicle accidents. According to the Centers for Disease Control and Prevention, motor vehicle injuries are the leading cause of death among children from 0 to 15 years of age, and in the United States during 2005, 1,335 children ages 14 years and younger died as occupants in motor vehicle accidents; approximately 184,000 were injured. That is an average of 4 deaths and 504 injuries each day. National Highway Traffic Safety Administration (NHTSA) statistics show that nearly one-half of deaths and injuries in children occurred because they were not properly restrained. Child safety seats and safety belts, when installed and used properly, can prevent injuries and save lives. Among children under age 5, an estimated 425 lives were saved in 2006 by child restraint use. Research on the effectiveness of child safety seats has found them to reduce fatal injury by 71% for infants, and by 54% for toddlers in passenger cars. This article discusses the need for increased education of parents and healthcare professionals about selection and installation of car safety restraints, and the importance of developing a child safety restraint program.

  12. A MATLAB-based eye tracking control system using non-invasive helmet head restraint in the macaque.

    Science.gov (United States)

    De Luna, Paolo; Mohamed Mustafar, Mohamed Faiz Bin; Rainer, Gregor

    2014-09-30

    Tracking eye position is vital for behavioral and neurophysiological investigations in systems and cognitive neuroscience. Infrared camera systems which are now available can be used for eye tracking without the need to surgically implant magnetic search coils. These systems are generally employed using rigid head fixation in monkeys, which maintains the eye in a constant position and facilitates eye tracking. We investigate the use of non-rigid head fixation using a helmet that constrains only general head orientation and allows some freedom of movement. We present a MATLAB software solution to gather and process eye position data, present visual stimuli, interact with various devices, provide experimenter feedback and store data for offline analysis. Our software solution achieves excellent timing performance due to the use of data streaming, instead of the traditionally employed data storage mode for processing analog eye position data. We present behavioral data from two monkeys, demonstrating that adequate performance levels can be achieved on a simple fixation paradigm and show how performance depends on parameters such as fixation window size. Our findings suggest that non-rigid head restraint can be employed for behavioral training and testing on a variety of gaze-dependent visual paradigms, reducing the need for rigid head restraint systems for some applications. While developed for macaque monkey, our system of course can work equally well for applications in human eye tracking where head constraint is undesirable. Copyright © 2014. Published by Elsevier B.V.

  13. Social isolation alters central nervous system monoamine content in prairie voles following acute restraint.

    Science.gov (United States)

    McNeal, Neal; Anderson, Eden M; Moenk, Deirdre; Trahanas, Diane; Matuszewich, Leslie; Grippo, Angela J

    2018-04-01

    Animal models have shown that social isolation and other forms of social stress lead to depressive- and anxiety-relevant behaviors, as well as neuroendocrine and physiological dysfunction. The goal of this study was to investigate the effects of prior social isolation on neurotransmitter content following acute restraint in prairie voles. Animals were either paired with a same-sex sibling or isolated for 4 weeks. Plasma adrenal hormones and ex vivo tissue concentrations of monoamine neurotransmitters and their metabolites were measured following an acute restraint stressor in all animals. Isolated prairie voles displayed significantly increased circulating adrenocorticotropic hormone levels, as well as elevated serotonin and dopamine levels in the hypothalamus, and potentially decreased levels of serotonin in the frontal cortex. However, no group differences in monoamine levels were observed in the hippocampus or raphe. The results suggest that social stress may bias monoamine neurotransmission and stress hormone function to subsequent acute stressors, such as restraint. These findings improve our understanding of the neurobiological mechanisms underlying the consequences of social stress.

  14. Increase in best practice child car restraint use for children aged 2-5 years in low socioeconomic areas after introduction of mandatory child restraint laws.

    Science.gov (United States)

    Brown, Julie; Keay, Lisa; Hunter, Kate; Bilston, Lynne E; Simpson, Judy M; Ivers, Rebecca

    2013-06-01

    To examine changes in child car restraint practices in low socioeconomic areas following the introduction of mandatory child car restraint legislation in New South Wales (NSW), Australia. Data from two cross-sectional studies of child car restraint use at pre-schools, early childhood centres and primary schools before and after the introduction of legislating mandatory age-appropriate car restraint use for children up to the age of seven years was used in this analysis. All included observations were from local government areas with socioeconomic status in the lowest 30% of urban Sydney. Children aged 2-5 years were observed in their vehicles as they arrived at observation sites (107 pre-legislation, 360 post-legislation). Multilevel logistic regression was used to examine changes in observed age-appropriate and correct use of car restraints. Age-appropriate car restraint use was higher post-legislation than pre-legislation. After controlling for child's age, parental income, language spoken at home and adjusting for clustering, the odds of children being appropriately restrained post-legislation were 2.3 times higher than in the pre-legislation sample, and the odds of them being correctly restrained were 1.6 times greater. Results indicate an improvement in car restraint practices among children aged 2-5 in low socioeconomic areas after introduction of child restraint laws. Implications : Despite improvements observed with enhanced legislation, further efforts are required to increase optimal child car restraint use. © 2013 The Authors. ANZJPH © 2013 Public Health Association of Australia.

  15. Deep venous thrombosis and pulmonary embolism following physical restraint

    DEFF Research Database (Denmark)

    Laursen, S B; Jensen, T N; Bolwig, T

    2005-01-01

    . The literature on physical restraint, DVT, and PE was reviewed using a search of Medline and Psychinfo from 1966 to the present. RESULTS: Four other reported cases of DVT and PE were found in association with physically restrained patients. CONCLUSION: Risk of DVT and PE in association with immobilization during......OBJECTIVE: We describe a case of deep venous thrombosis (DVT) and pulmonary embolism (PE) following the use of physical restraint in a patient with a diagnosis of acute delusional psychotic disorder. METHOD: A new case report of DVT and PE associated with prolonged physical restraint is presented...... physical restraint may occur in spite of no pre-existing risk factors. Medical guidelines for the prevention of thrombosis following physical restraint are presented. Despite the absence of controlled trials of treatment effectiveness, the catastrophic outcome of DVT and PE warrants early and vigorous...

  16. Exogenous agmatine has neuroprotective effects against restraint-induced structural changes in the rat brain

    Science.gov (United States)

    Zhu, Meng-Yang; Wang, Wei-Ping; Cai, Zheng-Wei; Regunathan, Soundar; Ordway, Gregory

    2009-01-01

    Agmatine is an endogenous amine derived from decarboxylation of arginine catalysed by arginine decarboxylase. Agmatine is considered a novel neuromodulator and possesses neuroprotective properties in the central nervous system. The present study examined whether agmatine has neuroprotective effects against repeated restraint stress-induced morphological changes in rat medial prefrontal cortex and hippocampus. Sprague-Dawley rats were subjected to 6 h of restraint stress daily for 21 days. Immunohistochemical staining with β-tubulin III showed that repeated restraint stress caused marked morphological alterations in the medial prefrontal cortex and hippocampus. Stress-induced alterations were prevented by simultaneous treatment with agmatine (50 mg/kg/day, i.p.). Interestingly, endogenous agmatine levels, as measured by high-performance liquid chromatography, in the prefrontal cortex and hippocampus as well as in the striatum and hypothalamus of repeated restraint rats were significantly reduced as compared with the controls. Reduced endogenous agmatine levels in repeated restraint animals were accompanied by a significant increase of arginine decarboxylase protein levels in the same regions. Moreover, administration of exogenous agmatine to restrained rats abolished increases of arginine decarboxylase protein levels. Taken together, these results demonstrate that exogenously administered agmatine has neuroprotective effects against repeated restraint-induced structural changes in the medial prefrontal cortex and hippocampus. These findings indicate that stress-induced reductions in endogenous agmatine levels in the rat brain may play a permissive role in neuronal pathology induced by repeated restraint stress. PMID:18364017

  17. Ergonomic Evaluation of the Foot Restraint Equipment Device (FRED)

    Science.gov (United States)

    Whitmore, Mihriban; Chmielewski, Cindy; Qazi, A. S.; Mount, Francis

    1999-01-01

    Within the scope of the Microgravity Workstation and Restraint Evaluation project, funded by the NASA Headquarters Life Sciences Division, evaluations were proposed to be conducted in ground, KC-135, and/or Shuttle environments to investigate the human factors engineering (HFE) issues concerning confined/unique workstations, including crew restraint requirements. As part of these evaluations, KC-135 flights were conducted to investigate user/ workstation/ restraint integration for microgravity use of the FRED with the RMS workstation. This evaluation was a pre-cursor to Detailed Supplementary Objective (DSO) - 904 on STS-88. On that mission, a small-statured astronaut will be using the FRED restraint while working at the Aft RMS workstation. The DSO will collect video for later posture analyses, as well as subjective data in the form of an electronic questionnaire. This report describes the current FRED KC-135 evaluations. The primary objectives were to evaluate the usability of the FRED and to verify the DSO in-flight setup. The restraint interface evaluation consisted of four basic areas of restraint use: 1) adjustability; 2) general usability and comfort; 3) usability at the RMS workstation; and 4) assembly and disassembly.

  18. Adjustable, physiological ventricular restraint improves left ventricular mechanics and reduces dilatation in an ovine model of chronic heart failure.

    Science.gov (United States)

    Ghanta, Ravi K; Rangaraj, Aravind; Umakanthan, Ramanan; Lee, Lawrence; Laurence, Rita G; Fox, John A; Bolman, R Morton; Cohn, Lawrence H; Chen, Frederick Y

    2007-03-13

    Ventricular restraint is a nontransplantation surgical treatment for heart failure. The effect of varying restraint level on left ventricular (LV) mechanics and remodeling is not known. We hypothesized that restraint level may affect therapy efficacy. We studied the immediate effect of varying restraint levels in an ovine heart failure model. We then studied the long-term effect of restraint applied over a 2-month period. Restraint level was quantified by use of fluid-filled epicardial balloons placed around the ventricles and measurement of balloon luminal pressure at end diastole. At 4 different restraint levels (0, 3, 5, and 8 mm Hg), transmural myocardial pressure (P(tm)) and indices of myocardial oxygen consumption (MVO2) were determined in control (n=5) and ovine heart failure (n=5). Ventricular restraint therapy decreased P(tm) and MVO2, and improved mechanical efficiency. An optimal physiological restraint level of 3 mm Hg was identified to maximize improvement without an adverse affect on systemic hemodynamics. At this optimal level, end-diastolic P(tm) and MVO2 indices decreased by 27% and 20%, respectively. The serial longitudinal effects of optimized ventricular restraint were then evaluated in ovine heart failure with (n=3) and without (n=3) restraint over 2 months. Optimized ventricular restraint prevented and reversed pathological LV dilatation (130+/-22 mL to 91+/-18 mL) and improved LV ejection fraction (27+/-3% to 43+/-5%). Measured restraint level decreased over time as the LV became smaller, and reverse remodeling slowed. Ventricular restraint level affects the degree of decrease in P(tm), the degree of decrease in MVO2, and the rate of LV reverse remodeling. Periodic physiological adjustments of restraint level may be required for optimal restraint therapy efficacy.

  19. Restraint reduction in a nursing home and its impact on employee attitudes.

    Science.gov (United States)

    Sundel, M; Garrett, R M; Horn, R D

    1994-04-01

    To reduce physical restraint use in a nursing home and increase employee support for the restraint-reduction program. A one-group pretest-posttest design with repeated measures was used to determine changes in restraint use with participants over a 14-month interval. All individuals employed at the nursing home were surveyed at two time periods to determine their opinions on restraint use. A 265-bed private, non-profit nursing home in Dallas, Texas. A restrained cohort of 170 residents with a mean age of 84 years; 84% were female. A total of 182 employees participated in the first survey and 209 in the second. Formation of a project team that planned and supervised restraint removal. Inservice training on restraint use was conducted for all employees. Type and frequency of restraint use among the restrained cohort at four evaluation points within a 14-month interval. The frequency of restraint use in the nursing home population was also recorded. Survey measures included employee responses to a 16-item closed-end questionnaire before and after training. The mean number of restraints used with each resident in the restrained cohort decreased from 1.56 to 0.67. The number of residents on restraints in the nursing home was reduced during the course of the study (67.5% vs. 36.7%, P reduction program in a nursing home can produce positive results in terms of decreased restraint use and supportive employee attitudes. More practical alternatives to restraints need to be developed for application in the training of nursing home employees. Future studies on resident, employee, and family attitudes about restraint use are suggested.

  20. Real-world adjustments of driver seat and head restraint in Saab 9-3 vehicles.

    Science.gov (United States)

    Carlsson, Anna; Pipkorn, Linda; Kullgren, Anders; Svensson, Mats

    2017-05-19

    Whiplash-associated disorder (WAD), commonly denoted whiplash injury, is a worldwide problem. These injuries occur at relatively low changes of velocity (typically whiplash injury than males.  Improved seat design is the prevailing means of increasing the protection of whiplash injury for occupants in rear impacts. Since 1997, more advanced whiplash protection systems have been introduced on the market, the Saab Active Head Restraint (SAHR) being one of the most prominent. The SAHR-which is height adjustable-is mounted to a pressure plate in the seatback by means of a spring-resisted link mechanism.  Nevertheless, studies have shown that seats equipped with reactive head restraints (such as the SAHR) have a very high injury-reducing effect for males (∼60-70%) but very low or no reduction effect for females. One influencing factor could be the position of the head restraint relative to the head, because a number of studies have reported that adjustable head restraints often are incorrectly positioned by drivers.  The aim was to investigate how female and male Saab drivers adjust the seat in the car they drive the most. The seated positions of drivers in stationary conditions have been investigated in a total of 76 volunteers (34 females, 42 males) who participated in the study. Inclusion criteria incorporated driving a Saab 9-3 on a regularly basis. The majority of the volunteers (89%) adjusted the head restraint to any of the 3 uppermost positions and as many as 59% in the top position.  The average vertical distance between the top of the head and the top of the head restraint (offset) increase linearly with increasing statures, from an average of -26 mm (head below the head restraint) for small females to an average of 82 mm (head above the head restraint) for large males. On average, the offset was 23 mm for females, which is within a satisfactory range and in accordance with recommendations; the corresponding value for males was 72 mm.

  1. Acute restraint stress induces endothelial dysfunction: role of vasoconstrictor prostanoids and oxidative stress.

    Science.gov (United States)

    Carda, Ana P P; Marchi, Katia C; Rizzi, Elen; Mecawi, André S; Antunes-Rodrigues, José; Padovan, Claudia M; Tirapelli, Carlos R

    2015-01-01

    We hypothesized that acute stress would induce endothelial dysfunction. Male Wistar rats were restrained for 2 h within wire mesh. Functional and biochemical analyses were conducted 24 h after the 2-h period of restraint. Stressed rats showed decreased exploration on the open arms of an elevated-plus maze (EPM) and increased plasma corticosterone concentration. Acute restraint stress did not alter systolic blood pressure, whereas it increased the in vitro contractile response to phenylephrine and serotonin in endothelium-intact rat aortas. NG-nitro-l-arginine methyl ester (l-NAME; nitric oxide synthase, NOS, inhibitor) did not alter the contraction induced by phenylephrine in aortic rings from stressed rats. Tiron, indomethacin and SQ29548 reversed the increase in the contractile response to phenylephrine induced by restraint stress. Increased systemic and vascular oxidative stress was evident in stressed rats. Restraint stress decreased plasma and vascular nitrate/nitrite (NOx) concentration and increased aortic expression of inducible (i) NOS, but not endothelial (e) NOS. Reduced expression of cyclooxygenase (COX)-1, but not COX-2, was observed in aortas from stressed rats. Restraint stress increased thromboxane (TX)B(2) (stable TXA(2) metabolite) concentration but did not affect prostaglandin (PG)F2α concentration in the aorta. Restraint reduced superoxide dismutase (SOD) activity, whereas concentrations of hydrogen peroxide (H(2)O(2)) and reduced glutathione (GSH) were not affected. The major new finding of our study is that restraint stress increases vascular contraction by an endothelium-dependent mechanism that involves increased oxidative stress and the generation of COX-derived vasoconstrictor prostanoids. Such stress-induced endothelial dysfunction could predispose to the development of cardiovascular diseases.

  2. Financial Restraints in the South Korean Miracle

    OpenAIRE

    Panicos O Demetriades; Kul B Luintel

    2000-01-01

    We provide novel empirical evidence on the effects of financial restraints on South Korean financial development. The evidence is linked to a simple model of the Korean banking system that encapsulates its cartelised nature, which predicts a positive association between financial development and (i) the degree of state control over the banking system, (ii) mild repression of lending rates. The model also predicts that in the presence of lending rate controls, increases in the level of the adm...

  3. 32 CFR 884.3 - Placing member under restraint pending delivery.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Placing member under restraint pending delivery. 884.3 Section 884.3 National Defense Department of Defense (Continued) DEPARTMENT OF THE AIR FORCE... member under restraint pending delivery. Continue restraint only as long as is reasonably necessary to...

  4. Physical Restraint Initiation in Nursing Homes and Subsequent Resident Health

    Science.gov (United States)

    Engberg, John; Castle, Nicholas G.; McCaffrey, Daniel

    2008-01-01

    Purpose: It is widely believed that physical restraint use causes mental and physical health decline in nursing home residents. Yet few studies exist showing an association between restraint initiation and health decline. In this research, we examined whether physical restraint initiation is associated with subsequent lower physical or mental…

  5. An editor for the generation and customization of geometry restraints.

    Science.gov (United States)

    Moriarty, Nigel W; Draizen, Eli J; Adams, Paul D

    2017-02-01

    Chemical restraints for use in macromolecular structure refinement are produced by a variety of methods, including a number of programs that use chemical information to generate the required bond, angle, dihedral, chiral and planar restraints. These programs help to automate the process and therefore minimize the errors that could otherwise occur if it were performed manually. Furthermore, restraint-dictionary generation programs can incorporate chemical and other prior knowledge to provide reasonable choices of types and values. However, the use of restraints to define the geometry of a molecule is an approximation introduced with efficiency in mind. The representation of a bond as a parabolic function is a convenience and does not reflect the true variability in even the simplest of molecules. Another complicating factor is the interplay of the molecule with other parts of the macromolecular model. Finally, difficult situations arise from molecules with rare or unusual moieties that may not have their conformational space fully explored. These factors give rise to the need for an interactive editor for WYSIWYG interactions with the restraints and molecule. Restraints Editor, Especially Ligands (REEL) is a graphical user interface for simple and error-free editing along with additional features to provide greater control of the restraint dictionaries in macromolecular refinement.

  6. Sensitization of restraint-induced corticosterone secretion after chronic restraint in rats: Involvement of 5-HT7 receptors

    Science.gov (United States)

    García-Iglesias, Brenda B.; Mendoza-Garrido, María E.; Gutiérrez-Ospina, Gabriel; Rangel-Barajas, Claudia; Noyola-Díaz, Martha; Terrón, José A.

    2013-01-01

    Serotonin (5-HT) modulates the hypothalamic-pituitary-adrenal (HPA) axis response to stress. We examined the effect of chronic restraint stress (CRS; 20 min/day) as compared to control (CTRL) conditions for 14 days, on: 1) restraint-induced ACTH and corticosterone (CORT) secretion in rats pretreated with vehicle or SB-656104 (a 5-HT7 receptor antagonist); 2) 5-HT7 receptor-like immunoreactivity (5-HT7-LI) and protein in the hypothalamic paraventricular nucleus (PVN) and adrenal glands (AG); 3) baseline levels of 5-HT and 5-hydroxyindolacetic acid (5-HIAA), and 5-HIAA/5-HT ratio in PVN and AG; and 4) 5-HT-like immunoreactivity (5-HT-LI) in AG and tryptophan hydroxylase (TPH) protein in PVN and AG. On day 15, animals were subdivided into Treatment and No treatment groups. Treatment animals received an i.p. injection of vehicle or SB-656104; No Treatment animals received no injection. Sixty min later, Treatment animals were either decapitated with no further stress (0 min) or submitted to acute restraint (10, 30, 60 or 120 min); hormone serum levels were measured. No Treatment animals were employed for the rest of measurements. CRS decreased body weight gain and increased adrenal weight. In CTRL animals, acute restraint increased ACTH and CORT secretion in a time of restraint-dependent manner; both responses were inhibited by SB-656104. Exposure to CRS abolished ACTH but magnified CORT responses to restraint as compared to CTRL conditions; SB-656104 had no effect on ACTH levels but significantly inhibited sensitized CORT responses. In CTRL animals, 5-HT7-LI was detected in magnocellular and parvocellular subdivisions of PVN and sparsely in adrenal cortex. Exposure to CRS decreased 5-HT7-LI and protein in the PVN, but increased 5-HT7-LI in the adrenal cortex and protein in whole AG. Higher 5-HT and 5-HIAA levels were detected in PVN and AG from CRS animals but 5-HIAA/5-HT ratio increased in AG only. Finally, whereas 5-HT-LI was sparsely observed in the adrenal cortex

  7. Evaluation Model for Restraint Effect of Pressure Induced Bending on the Plastic Crack Opening of Circumferential Through-Wall-Crack

    International Nuclear Information System (INIS)

    Kim, Jin-Weon

    2006-01-01

    Most of the pipe crack evaluation procedures, including leak-before-break (LBB) analysis, assume that the cracked pipe subjected to remote bending or internal pressure is free to rotate. In this case, the pressure induced bending (PIB) enhances crack opening of a through-wall-crack (TWC) in a pipe. In a real piping system, however, the PIB will be restrained because the ends of the pipe are constrained by the rest of the piping system. Hence, the amount of restraint affects the crack opening of a TWC in a pipe, and the restraint effect on crack opening directly affects the results of LBB evaluation. Therefore, it is necessary to investigate the restraint effect of PIB on crack opening displacement (COD) to quantify the uncertainties in current analysis procedures and to ensure the application of LBB concepts to nuclear piping systems. Recently, several researches were conducted to investigate the restraint effect of PIB on COD, and they proposed a simplified model to evaluate COD under restrained conditions. However, these results are quite limited because the restraint effect was evaluated only in terms of linear-elastic crack opening. In practice, the TWC in a pipe behaves plastically under normal operating loads, and the current LBB analysis methodologies require elastic-plastic crack opening evaluation. Therefore, this study evaluates the restraint effect of PIB on the plastic crack opening of a TWC in a pipe using finite element analysis under various influencing parameters. Based on these results, a closed-from model to be able to estimate the restraint effect of PIB on plastic crack opening is proposed

  8. Design of the core support and restraint structures for FFTF and CRBRP

    International Nuclear Information System (INIS)

    Sutton, H.G.; Rylatt, J.A.

    1977-12-01

    This paper presents and compares the design and fabrication of the FFTF and CRBRP reactor structures which support and restrain the reactor core assemblies. The fabrication of the core support structure (CSS) for the FFTF reactor was completed October 1972 and this paper discusses how the fabrication problems encountered with the FFTF were avoided in the subsequent design of the CRBR CSS. The radial core restraint structure of the FFTF was designed and fabricated such that an active system could replace the present passive system which is segmented and relies on the CSS core barrel for total structure integrity to maintain core geometry. The CRBR core restraint structure is designed for passive restraint only, and this paper discusses how the combined strengths of the restraint structure former rings and the CSS core barrel are utilized to maintain core geometry. Whereas the CSS for the FFTF interfaces directly with the reactor core assemblies, the CRBR CSS does not. A comparison is made on how intermediate structures in CRBR (inlet modules) provide the necessary design interfaces for supporting and providing flow distribution to the reactor core assemblies. A discussion is given on how the CRBR CSS satisfied the design requirements of the Equipment Specification, including thermal transient, dynamic and seismic loadings, and results of flow distribution testing that supported the CRBR design effort. The approach taken to simplify fabrication of the CRBR components, and a novel 20 inch deep narrow gap weld joint in the CSS are described

  9. Safety characteristics of the US advanced liquid metal reactor core

    International Nuclear Information System (INIS)

    Magee, P.M.; Dubberley, A.E.; Gyorey, G.L.; Lipps, A.J.; Wu, T.

    1991-01-01

    The U.S. Advanced Liquid Metal Reactor (ALMR) design employs innovative, passive features to provide an unprecedented level of public safety and the ability to demonstrate this safety to the public. The key features employed in the core design to produce the desired passive safety characteristics are: a small core with a tight restraint system, the use of metallic U-Pu-Zr fuel, control rod withdrawal limiters, and gas expansion modules. In addition, the reactor vessel and closure are designed to have the capability to withstand, with large margins, the maximum possible core disruptive accident without breach and radiological release. (author)

  10. Roadside observation of child passenger restraint use

    Directory of Open Access Journals (Sweden)

    Beth Bruce

    2015-10-01

    Full Text Available Background: Despite legislation and research evidence supporting the use of childhood vehicle restraints, motor vehicle crashes remain the leading cause of injury, death and disability among Canadian children. Methods: Working in collaboration with trained car seat specialists and police officers, roadside checks were conducted to observe correct use of child restraints. Results: Of the 1323 child vehicle restraints inspected, 99.6% of the children were restrained, 91% were in the correct seat, and 48% of restraints were correctly installed. The seat/restraint types most used incorrectly used were booster seats (31% and seat belts (53%. The majority of incorrectly installed or fitted seats (55% were forward facing. Common errors in installation and fit included the seat not being secured tightly enough to the vehicle, incorrect tether strap use, the harness not being tight enough, and/or the chest clip being in the wrong place. Conclusions: The greatest proportion of incorrect seat use was among those children who transitioned to a seat belt too soon. The greatest proportion of installation and fit errors were among forward facing seats. Researchers recommend: 1 targeting parents with older children (ages 3 and above regarding transitioning too soon from forward facing seats to booster seats, and from booster seats to seat belts; 2 targeting parents with younger children regarding correct installation of rear facing and forward facing seats; 3 collaborating with police officers to review the most common errors and encourage observation at roadside checks; and 4 creating community awareness by way of roadside checks.

  11. [Use of restraint in psychiatry: Feelings of caregivers and ethical perspectives].

    Science.gov (United States)

    Guivarch, J; Cano, N

    2013-09-01

    The return of restraint in psychiatry raises many ethical issues for caregivers. However their experience is little explored in literature. Our objective was to study the feelings of caregivers facing restraint with regard to an ethical perspective and to identify areas for improvement. Between November 2011 and February 2012 a descriptive cross-sectional epidemiological study was performed in two psychiatric emergency services and two closed units in which doctors and nurses were individually interviewed using semi-structured questionnaires. Five topics were explored: indications and contexts, impact on the patient, caregiver-patient relationship, perspective on the practice and feelings of caregivers on which we insist particularly. Results were presented in tables with percentages and possibly diagrams. The notable responses of caregivers were also cited. Twenty nurses and nine psychiatrists, mostly female, were recruited. They all had participated in experiments of restraint. The self-aggressiveness, the aggressiveness against other persons and agitation were the most frequent indications. In the patients, caregivers identified misunderstanding (79.3%) and anger (75.9%). The majority of nurses (75%) felt that there was an improvement in the caregiver-patient relationship after the episode of restraint compared to what it had been in the moments preceding this measure. The emotional experience of caregivers was rich, intense and predominantly negative type of frustration (35% of nurses; 66.7% of doctors), anger (30 and 33.3%) and lack of feeling (35 and 44.4%). The feelings of doctors and nurses were not completely similar. For caregivers it was "a difficult but necessary experience" (82.75%), "an act of care and safety" (68.9%). All psychiatrists and almost half of the nurses (45%) said they did not feel the same when they used seclusion. In their opinion, seclusion entailed a less painful experience because of its therapeutic properties. More than half of the

  12. Acute restraint stress induces hyperalgesia via non-adrenergic ...

    African Journals Online (AJOL)

    Analgesia or hyperalgesia has been reported to occur in animals under different stress conditions. This study examined the effect of acute restraint stress on nociception in rats. Acute restraint stress produced a time-dependant decrease in pain threshold; this hyperalgesia was not affected by prior administration of ...

  13. Crew Restraint Design for the International Space Station

    Science.gov (United States)

    Norris, Lena; Holden, Kritina; Whitmore, Mihriban

    2006-01-01

    With permanent human presence onboard the International Space Station (ISS), crews will be living and working in microgravity, dealing with the challenges of a weightless environment. In addition, the confined nature of the spacecraft environment results in ergonomic challenges such as limited visibility and access to the activity areas, as well as prolonged periods of unnatural postures. Without optimum restraints, crewmembers may be handicapped for performing some of the on-orbit tasks. Currently, many of the tasks on ISS are performed with the crew restrained merely by hooking their arms or toes around handrails to steady themselves. This is adequate for some tasks, but not all. There have been some reports of discomfort/calluses on the top of the toes. In addition, this type of restraint is simply insufficient for tasks that require a large degree of stability. Glovebox design is a good example of a confined workstation concept requiring stability for successful use. They are widely used in industry, university, and government laboratories, as well as in the space environment, and are known to cause postural limitations and visual restrictions. Although there are numerous guidelines pertaining to ventilation, seals, and glove attachment, most of the data have been gathered in a 1-g environment, or are from studies that were conducted prior to the early 1980 s. Little is known about how best to restrain a crewmember using a glovebox in microgravity. Another ISS task that requires special consideration with respect to restraints is robotic teleoperation. The Robot Systems Technology Branch at the NASA Johnson Space Center is developing a humanoid robot astronaut, or Robonaut. It is being designed to perform extravehicular activities (EVAs) in the hazardous environment of space. An astronaut located inside the ISS will remotely operate Robonaut through a telepresence control system. Essentially, the robot mimics every move the operator makes. This requires the

  14. Use of physical restraint: Nurses' knowledge, attitude, intention and practice and influencing factors.

    Science.gov (United States)

    Eskandari, Fatemeh; Abdullah, Khatijah Lim; Zainal, Nor Zuraida; Wong, Li Ping

    2017-12-01

    To investigate the knowledge, attitude, intention and practice of nurses towards physical restraint and factors influencing these variables. A literature review showed a lack of studies focused on the intention of nurses regarding physical restraint throughout the world. Considering that very little research on physical restraint use has been carried out in Malaysia, assessment of nurses' knowledge, attitude, intention and practice is necessary before developing a minimising programme in hospitals. A cross-sectional study was used. A questionnaire to assess the knowledge, attitude, intention and practice was completed by all nurses (n = 309) in twelve wards of a teaching hospital in Kuala Lumpur. Moderate knowledge and attitude with strong intention to use physical restraint were found among the nurses. Less than half of nurses considered alternatives to physical restraint and most of them did not understand the reasons for the physical restraint. Nurses' academic qualification, read any information source during past year and nurses' work unit showed a significant association with nurses' knowledge. Multiple linear regression analysis found knowledge, attitude and intention were significantly associated with nurses' practice to use physical restraint. This study showed some important misunderstandings of nurses about using physical restraint and strong intention regarding using physical restraint. Findings of this study serve as a supporting reason for importance of educating nurses about the use of physical restraint. Exploring the knowledge, attitude, intention and current practice of nurses towards physical restraint is important so that an effective strategy can be formulated to minimise the use of physical restraints in hospitals. © 2017 John Wiley & Sons Ltd.

  15. The restraint bias: how the illusion of self-restraint promotes impulsive behavior

    NARCIS (Netherlands)

    Nordgren, L.F.; van Harreveld, F.; van der Pligt, J.

    2009-01-01

    Four studies examined how impulse-control beliefs—beliefs regarding one's ability to regulate visceral impulses, such as hunger, drug craving, and sexual arousal—influence the self-control process. The findings provide evidence for a restraint bias: a tendency for people to overestimate their

  16. Console video games, postural activity, and motion sickness during passive restraint.

    Science.gov (United States)

    Chang, Chih-Hui; Pan, Wu-Wen; Chen, Fu-Chen; Stoffregen, Thomas A

    2013-08-01

    We examined the influence of passive restraint on postural activity and motion sickness in individuals who actively controlled a potentially nauseogenic visual motion stimulus (a driving video game). Twenty-four adults (20.09 ± 1.56 years; 167.80 ± 7.94 cm; 59.02 ± 9.18 kg) were recruited as participants. Using elastic bands, standing participants were passively restrained at the head, shoulders, hips, and knees. During restraint, participants played (i.e., controlled) a driving video game (a motorcycle race), for 50 min. During game play, we recorded the movement of the head and torso, using a magnetic tracking system. Following game play, participants answered a forced choice, yes/no question about whether they were motion sick, and were assigned to sick and well groups on this basis. In addition, before and after game play, participants completed the Simulator Sickness Questionnaire, which provided numerical ratings of the severity of individual symptoms. Five of 24 participants (20.83 %) reported motion sickness. Participants moved despite being passively restrained. Both the magnitude and the temporal dynamics of movement differed between the sick and well groups. The results show that passive restraint of the body can reduce motion sickness when the nauseogenic visual stimulus is under participants' active control and confirm that motion sickness is preceded by distinct patterns of postural activity even during passive restraint.

  17. [Physical and pharmacological restraints in geriatric and gerontology services and centers].

    Science.gov (United States)

    Ramos Cordero, Primitivo; López Trigo, José Antonio; Maíllo Pedraz, Herminio; Paz Rubio, José María

    2015-01-01

    Physical and pharmacological restraints are a controversial issue in the context of geriatric care due to their moral, ethical, social and legal repercussions and, despite this fact, no specific legislation exists at a national level. The use of restraints is being questioned with growing frequency, as there are studies that demonstrate that restraints do not reduce the number of falls or their consequences, but rather can increase them, cause complications, injuries and potentially fatal accidents. Restraints are not always used rationally, despite compromising a fundamental human right, that is, freedom, protected in the Constitution, as well as values and principles, such as dignity and personal self-esteem. There are centers where restraints are applied to more than 50% of patients, and in some cases without the consent of their legal representatives. On some occasions, restraints are used for attaining organizational or environmental objectives, such as complying with tight schedules, and for reducing or avoiding the supervision of patients who walk erratically and, at times, are used indefinitely. Even greater confusion exists with respect to the emerging concept of chemical or pharmacological restraints, since no conceptual framework exists based on scientific evidence, and with sufficient consensus for guiding healthcare workers. In this context, the Sociedad Española de Geriatría y Gerontología (SEGG--Spanish Geriatrics and Gerontology Society), aware of the significance and transcendence of the issue, and in an attempt to preserve and guarantee maximum freedom, dignity and self-esteem, on the one hand, and to ensure the maximum integrity and legal certainty of the persons cared for in geriatric and gerontology services and centers, on the other, decided to create an "Interdisciplinary Committee on Restraints" made up by members from different disciplines and members of SEGG Working Groups or Committees, external health care workers, groups

  18. Safety Education in Driving. 2nd Revision.

    Science.gov (United States)

    Ohio State Univ., Columbus. Vocational Instructional Materials Lab.

    Intended for driving instruction students, this publication contains instructional materials for safety education. It contains six sections on facts and figures; defensive driving; safety devices; restraints; emergency situations; and other highway users. Each section consists of reading material followed by an activity or activities. A total of…

  19. Environmental restraints and life strategies: a habitat templet matrix.

    Science.gov (United States)

    Holm, E

    1988-02-01

    Four basic environmental restraints on life are deduced from the requirements of life's inherent order laws. Possible life strategies to contend with these restraints are listed. The various combinations of the restraints are subsequently investigated, and appropriate combinations of life strategies are fitted. This model is finally tested against insect case histories in various environments, and is demonstrated to explain some combinations of characteristics of insects in ecosystems not covered by the r-K or r-K-A continua. The role of heterochrony in achieving appropriate life strategies is briefly discussed.

  20. Torsional Restraint Problem of Steel Cold-Formed Beams Restrained By Planar Members

    Science.gov (United States)

    Balázs, Ivan; Melcher, Jindřich; Pešek, Ondřej

    2017-10-01

    The effect of continuous or discrete lateral and torsional restraints of metal thinwalled members along their spans can positively influence their buckling resistance and thus contribute to more economical structural design. The prevention of displacement and rotation of the cross-section results in stabilization of the member. The restraints can practically be provided e.g. by planar members of cladding supported by metal members (purlins, girts). The rate of stabilization of a member can be quantified using values of shear and rotational stiffness provided by the adjacent planar members. While the lateral restraint effected by certain shear stiffness can be often considered as sufficient, the complete torsional restraint can be safely considered in some practical cases only. Otherwise the values of the appropriate rotational stiffness provided by adjacent planar members may not be satisfactory to ensure full torsional restraint and only incomplete restraint is available. Its verification should be performed using theoretical and experimental analyses. The paper focuses on problem of steel thin-walled coldformed beams stabilized by planar members and investigates the effect of the magnitude of the rotational stiffness provided by the planar members on the resistance of the steel members. Cold-formed steel beams supporting planar members of cladding are considered. Full lateral restraint and incomplete torsional restraint are assumed. Numerical analyses performed using a finite element method software indicate considerable influence of the torsional restraint on the buckling resistance of a steel thin-walled member. Utilization of the torsional restraint in the frame of sizing of a stabilized beam can result in more efficient structural design. The paper quantifies this effect for some selected cases and summarizes results of numerical analysis.

  1. Lateral restraint assembly for reactor core

    Science.gov (United States)

    Gorholt, Wilhelm; Luci, Raymond K.

    1986-01-01

    A restraint assembly for use in restraining lateral movement of a reactor core relative to a reactor vessel wherein a plurality of restraint assemblies are interposed between the reactor core and the reactor vessel in circumferentially spaced relation about the core. Each lateral restraint assembly includes a face plate urged against the outer periphery of the core by a plurality of compression springs which enable radial preloading of outer reflector blocks about the core and resist low-level lateral motion of the core. A fixed radial key member cooperates with each face plate in a manner enabling vertical movement of the face plate relative to the key member but restraining movement of the face plate transverse to the key member in a plane transverse to the center axis of the core. In this manner, the key members which have their axes transverse to or subtending acute angles with the direction of a high energy force tending to move the core laterally relative to the reactor vessel restrain such lateral movement.

  2. The Relationship between Restraints of Trade and Garden Leave

    Directory of Open Access Journals (Sweden)

    Yeukai Mupangavanhu

    2017-06-01

    Full Text Available The purpose of the article is to examine the relationship between a so-called "garden leave" clause and a post-termination restraint of trade clause in employment contracts, in view of the decision in Vodacom (Pty Ltd v Motsa 2016 3 SA 116 (LC. The Labour Court grappled with the question of whether the enforcement of the garden leave provision impacts on the enforcement of a post-termination restraint of trade clause. Enforcement of both these types of clauses may be problematic. It can result in unfairness if an employee ends up being commercially inactive for a long period. The author argues that garden leave has a direct effect on the enforcement of a post- termination restraint of trade clause. Accordingly, a restraint of trade will be enforced only if the employer's proprietary interest requires additional protection beyond what is achieved under the garden leave clause.

  3. The relationship between restraints of trade and garden leave ...

    African Journals Online (AJOL)

    The relationship between restraints of trade and garden leave. ... Potchefstroom Electronic Law Journal/Potchefstroomse Elektroniese Regsblad ... The purpose of the article is to examine the relationship between a so-called "garden leave" clause and a post-termination restraint of trade clause in employment contracts, ...

  4. Do head-restraints protect the neck from whiplash injuries?

    Science.gov (United States)

    Morris, F

    1989-01-01

    Over an 11-month period a study was made of all patients presenting to an accident and emergency department who had sustained whiplash as a result of rear-bumper impacts. The patients were analysed with respect to the presence of head-restraints in their vehicles. A significant increase in the incidence of whiplash was found in patients whose vehicles did not have head-restraints fitted. Legislation requiring all passenger cars to have head-restraints fitted as standard would have a major impact in reducing the number of whiplash injuries sustained in rear bumper impacts. PMID:2712983

  5. Behavioral effects of acclimatization to restraint protocol used for awake animal imaging.

    Science.gov (United States)

    Reed, Michael D; Pira, Ashley S; Febo, Marcelo

    2013-07-15

    Functional MRI in awake rats involves acclimatization to restraint to minimize motion. We designed a study to examine the effects of an acclimatization protocol (5 days of restraint, 60 min per day) on the emission of 22-kHz ultrasonic vocalizations and performance in a forced swim test (FST). Our results showed that USV calls are reduced significantly by days 3, 4 and 5 of acclimatization. Although the rats showed less climbing activity (and more immobility) in FST on day 5 compared to the 1st day of restraint acclimatization, the difference was not detected once the animals were given a 2-week hiatus. Overall, we showed that animals adapt to the restraint over a five-day period; however, restraint may introduce confounding behavioral outcomes that may hinder the interpretation of results derived from awake rat imaging. The present data warrants further testing of the effects of MRI restraint on behavior. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Assessment of elementary school safety restraint programs.

    Science.gov (United States)

    1985-06-01

    The purpose of this research was to identify elementary school (K-6) safety belt : education programs in use in the United States, to review their development, and : to make administrative and impact assessments of their use in selected States. : Six...

  7. AT89S52 Microcontroller Based A Speed Restraint Equipment for Motorcycle

    Directory of Open Access Journals (Sweden)

    Ikhsan hidayat

    2009-08-01

    Full Text Available Security riding is very important in the aspects of traffic. One of the main factors of traffic accidents is high speed. Therefore, it is required a speed restraint equipment for pressing the number of accidents. The car speed restraint system is available in the market, but on a motorcycle is not available yet. This paper presents a design of speed restraint equipment for motorcycle that safe for users, and is expected to reduce traffic accident. The Main idea this speed restriction is cutting off the flow of electrical signals from the pulser (the time ignition trigger sensor to the CDI for 1 second. The cutting Signal with mechanical relays controlled by microcontroller AT89S52 using the on-off algorithm. Speed sensor use optocoupler is used to detect the number of rounds wheel motorcycle. If a result of measurement is more than the speed setpoint, microcontroler make a decission to cut motorcycle ignition signal. Results of this research is a prototype speed restraint shown that it able to process data from the measurement of the speed limit on the speed of a motorcycle. This prototype safe for all users and accordance with the set value and the level of success is above 90% for speed of 10 km/hr to 40 km/hr.

  8. Traffic Safety Facts - Research Note: Additional Analysis of National Child Restraint Use Special Study: Characteristics Of Those Not Restrained

    Science.gov (United States)

    2018-03-01

    The National Child Restraint Use Special Study (NCRUSS) recorded the use of car seats and belt-positioning booster seats in children up to 8 years old in 4,167 vehicles. Observers approached vehicles that carried at least one child. They interviewed ...

  9. Optimizing the passenger air bag of an adaptive restraint system for multiple size occupants.

    Science.gov (United States)

    Bai, Zhonghao; Jiang, Binhui; Zhu, Feng; Cao, Libo

    2014-01-01

    The development of the adaptive occupant restraint system (AORS) has led to an innovative way to optimize such systems for multiple size occupants. An AORS consists of multiple units such as adaptive air bags, seat belts, etc. During a collision, as a supplemental protective device, air bags can provide constraint force and play a role in dissipating the crash energy of the occupants' head and thorax. This article presents an investigation into an adaptive passenger air bag (PAB). The purpose of this study is to develop a base shape of a PAB for different size occupants using an optimization method. Four typical base shapes of a PAB were designed based on geometric data on the passenger side. Then 4 PAB finite element (FE) models and a validated sled with different size dummy models were developed in MADYMO (TNO, Rijswijk, The Netherlands) to conduct the optimization to obtain the best baseline PAB that would be used in the AORS. The objective functions-that is, the minimum total probability of injuries (∑Pcomb) of the 5th percentile female and 50th and 95th percentile male dummies-were adopted to evaluate the optimal configurations. The injury probability (Pcomb) for each dummy was adopted from the U.S. New Car Assessment Program (US-NCAP). The parameters of the AORS were first optimized for different types of PAB base shapes in a frontal impact. Then, contact time duration and force between the PAB and dummy head/chest were optimized by adjusting the parameters of the PAB, such as the number and position of tethers, lower the Pcomb of the 95th percentile male dummy. According to the optimization results, 4 typical PABs could provide effective protection to 5th and 50th percentile dummies. However, due to the heavy and large torsos of the 95th percentile occupants, the current occupant restraint system does not demonstrate satisfactory protective function, particularly for the thorax.

  10. Striving for balance between caring and restraint

    DEFF Research Database (Denmark)

    Moberg, Julie Y; Larsen, Dorte; Brødsgaard, Anne

    2017-01-01

    with 14 young adults were conducted. RESULTS: The essence of the phenomenon of having a parent with multiple sclerosis was synthesized into 'Striving for balance between caring and restraint' from two themes 'caring' and 'restraint' and eight subthemes. Participants' experiences of caring for parents...... that one of the greatest challenges of having a parent with multiple sclerosis is achieving a balance between caring for others and asserting one's own desires. RELEVANCE TO CLINICAL PRACTICE: Health care professionals can support the family by encouraging family members to participate in consultations...

  11. 75 FR 9613 - Draft NIJ Restraints Standard for Criminal Justice

    Science.gov (United States)

    2010-03-03

    ... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1512] Draft NIJ Restraints Standard for Criminal Justice AGENCY: National Institute of Justice, Office of Justice Programs, DOJ. ACTION: Notice of Draft NIJ Restraints Standard for Criminal Justice and Certification Program...

  12. System safety education focused on flight safety

    Science.gov (United States)

    Holt, E.

    1971-01-01

    The measures necessary for achieving higher levels of system safety are analyzed with an eye toward maintaining the combat capability of the Air Force. Several education courses were provided for personnel involved in safety management. Data include: (1) Flight Safety Officer Course, (2) Advanced Safety Program Management, (3) Fundamentals of System Safety, and (4) Quantitative Methods of Safety Analysis.

  13. Physical and mechanical restraint in psychiatric units: Perceptions and experiences of nursing staff.

    Science.gov (United States)

    Vedana, Kelly Graziani Giacchero; da Silva, Danielle Maria; Ventura, Carla Aparecida Arena; Giacon, Bianca Cristina Ciccone; Zanetti, Ana Carolina Guidorizzi; Miasso, Adriana Inocenti; Borges, Tatiana Longo

    2018-06-01

    Physical restraint in psychiatric units is a common practice but extremely controversial and poorly evaluated by methodologically appropriate investigations. The cultural issues and professionals' perceptions and attitudes are substantial contributors to the frequency of restraint that tend to be elevated. Aim In this qualitative study, we aimed to understand the experiences and perceptions of nursing staff regarding physical restraint in psychiatric units. Through theoretical sampling, 29 nurses from two Brazilian psychiatric units participated in the study. Data were collected from 2014 to 2016 from individual interviews and analyzed through thematic analysis, employing theoretical presuppositions of symbolic interactionism. Physical restraint was considered unpleasant, challenging, risky, and associated with dilemmas and conflicts. The nursing staff was often exposed to the risks and injuries related to restraint. Professionals sought strategies to reduce restraint-related damages, but still considered it necessary due to the lack of effective options to control aggressive behavior. This study provides additional perspectives about physical restraint and reveals the need for safer, humanized and appropriate methods for the care of aggressive patients that consider the real needs and rights of these patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Wheelchair tiedown and occupant restraint practices in paratransit vehicles.

    Directory of Open Access Journals (Sweden)

    Karen Frost

    Full Text Available The purpose of this study was to characterize wheelchair tiedown and occupant restraint system (WTORS usage in paratransit vehicles based on observations of wheelchair and scooter (wheeled mobility devices, collectively, "WhMD" passenger trips. A retrospective review of on-board video monitoring recordings of WhMD trips was conducted. Four hundred seventy-five video recordings were collected for review and analysis. The use of all four tiedowns to secure the WhMD was observed more frequently for power WhMDs (82% and manual WhMDs (80% compared to scooters (39%, and this difference was significant (p< 0.01. Nonuse or misuse of the occupant restraint system occurred during 88% of WhMD trips, and was most frequently due to vehicle operator neglect in applying the shoulder belt. Despite the absence of incidents or injuries in this study, misuse and nonuse of WTORS potentially place WhMD seated passengers at higher risk of injury during transit. These findings support the need for improved vehicle operator training and passenger education on the proper use of WTORS and development of WTORS with improved usability and/or alternative technologies that can be automated or used independently.

  15. Pipe restraints for nuclear power plants

    International Nuclear Information System (INIS)

    Keever, R.E.; Broman, R.; Shevekov, S.

    1976-01-01

    A pipe restraint for nuclear power plants in which a support member is anchored on supporting surface is described. Formed in the support member is a semicylindrical wall. Seated on the semicylindrical wall is a ring-shaped pipe restrainer that has an inner cylindrical wall. The inner cylindrical wall of the pipe restrainer encircles the pressurized pipe. In a modification of the pipe restraint, an arched-shaped pipe restrainer is disposed to overlie a pressurized pipe. The ends of the arch-shaped pipe restrainer are fixed to support members, which are anchored in concrete or to a supporting surface. A strap depends from the arch-shaped pipe restrainer. The pressurized pipe is supported by the depending strap

  16. Minimizing Restraint and Seclusion in Schools: A Response to Beaudoin and Moore.

    Science.gov (United States)

    Walker, Virginia L; Pinkelman, Sarah E

    2018-06-01

    Increasing efforts have been made in the field of special education to identify positive, evidence-based practices (EBPs) to meet the needs of students who engage in problem behavior, with a major goal being to eliminate or limit the use of reactive measures such as restraint and seclusion ( Snell & Walker, 2014 ). Various stakeholders, including families and self-advocates, have voiced concerns about the dangers of restraint and seclusion and the lack of protection afforded to students who engage in severe problem behavior. In the previous article in this issue of Intellectual and Developmental Disabilities, Beaudoin and Moore (2018) echo these concerns in their account of a family's experience with restraint as told from the perspective of a father whose son was subjected to restraint, resulting in a number of adverse short- and long-term consequences that affected the entire family. In response to Beaudoin and Moore, we provide readers with a brief review of the current status of restraint and seclusion in school settings and evidence-based strategies that can be used to address severe problem behavior and reduce the need for restraint and seclusion. For readers interested in exploring restraint and seclusion in greater depth, we suggest recent work by Trader and colleagues (2017) . We also have outlined guidelines for behavior support planning that should be considered by various stakeholders as educators work toward establishing safe and supportive school environments that address a wide range of student behavioral needs.

  17. A new approach for applying residual dipolar couplings as restraints in structure elucidation

    International Nuclear Information System (INIS)

    Meiler, Jens; Blomberg, Niklas; Nilges, Michael; Griesinger, Christian

    2000-01-01

    Residual dipolar couplings are useful global structural restraints. The dipolar couplings define the orientation of a vector with respect to the alignment tensor. Although the size of the alignment tensor can be derived from the distribution of the experimental dipolar couplings, its orientation with respect to the coordinate system of the molecule is unknown at the beginning of structure determination. This causes convergence problems in the simulated annealing process. We therefore propose a protocol that translates dipolar couplings into intervector projection angles, which are independent of the orientation of the alignment tensor with respect to the molecule. These restraints can be used during the whole simulated annealing protocol

  18. Dietary restraint, anxiety, and the relative reinforcing value of snack food in non-obese women.

    Science.gov (United States)

    Goldfield, Gary S; Legg, Christine

    2006-11-01

    This study tested the independent and interactive effects of anxiety and dietary restraint on the relative reinforcing value of snack food. Thirty non-obese, female university students were assigned to one of four groups based on median split scores on measures of dietary restraint and state-anxiety: low-restraint/low-anxiety (n=7), low-restraint/high-anxiety (n=7), high-restraint/low-anxiety (n=9), and high-restraint/high-anxiety (n=7). Participants were provided the choice to earn points for palatable snack foods or fruits and vegetables using a computerized concurrent schedules choice task. The behavioural cost to gain access to snack foods increased across trials, whereas the cost to gain access to fruits and vegetables was held constant across trials. The relative reinforcing value of palatable snack food in relation to fruits and vegetables was defined as the total amount of points earned for snack food. Two-way analysis of covariance, with hunger and hedonic snack food ratings as covariates, showed that dietary restraint and anxiety had a significant interactive effect on the relative reinforcing value of snack food, indicating that the effect of anxiety on snack food reinforcement is moderated by dietary restraint. Specifically, the high-anxiety/low-restraint women found snack food significantly less reinforcing than low-anxiety/low-restraint women, but no differences emerged between high- and low-anxiety women with high-restraint. Neither restraint nor anxiety had an independent effect on the relative reinforcing value of snack food. These findings indicate that anxiety may have a suppressive effect on the relative reinforcing value of snack food in low-restrained eaters, but not an enhancing effect on snack food reinforcement in high-restrained eaters. Clinical implications of these findings are discussed.

  19. Protecting children: a survey of caregivers’ knowledge of Georgia’s child restraint laws

    Directory of Open Access Journals (Sweden)

    Sheryl Strasser

    2010-11-01

    Full Text Available Sheryl Strasser1, Laurie Whorton2, Amanda J Walpole3, Sarah Beddington11Institute of Public Health, Partnership for Urban Health Research, Georgia State University, Atlanta, GA, USA; 2WellStar Corporate and Community Health, Marietta, GA, USA; 3Cobb and Douglas Public Health, Marietta, GA, USAIntroduction: The leading cause of injury and death among children in the United States is motor vehicle crashes. Even though restraint laws are in place and public awareness campaigns and educational interventions have increased, many children are still improperly restrained or not restrained at all. When correctly used, child restraints significantly reduce risk of injury or death.Methods: The purpose of the study was to elicit caregiver baseline knowledge of car seat installation and regulation before receiving car seat education from certified technicians at Inspection Station events. Inspection Station is a program whereby staff assists parents in correctly positioning car seats in participants’ vehicles. Over an 8-week period, Safe Kids Cobb County Car Seat Technicians distributed a 16-item survey, with 10 knowledge-based questions and six demographic questions to Inspection Station participants. Descriptive statistics and t-tests were conducted to assess relationships between participant age, ethnicity, and gender with overall knowledge scores. Regression analysis was run to determine the association between participant education level and total child restraint knowledge.Results: One hundred sixty-nine surveys were completed. Participant knowledge of vehicular child restraint ranged from 0% to 90% on all items. Only 29.6% of caregivers understood the proper tightness of the harness system. Less than half of the caregivers (43.8% were aware of the Georgia law requiring children aged 6 years and younger to be in some type of child restraint. Only 43.2% of caregivers surveyed knew that children need to ride in a rear-facing child restraint until 1

  20. Chronic restraint stress exacerbates nociception and inflammatory response induced by bee venom in rats: the role of the P2X7 receptors.

    Science.gov (United States)

    Li, Xiao-Qiu; Li, Man; Zhou, Zhong-He; Liu, Bao-Jun; Chen, Hui-Sheng

    2016-02-01

    Chronic restraint stress exacerbates pain and inflammation. The present study was designed to evaluate the effect of chronic restraint stress on inflammatory pain induced by subcutaneous injection of bee venom (BV). First, we investigated: (1) the effect of two-week restraint stress with daily 2 or 8 h on the baseline paw withdrawal mechanical threshold (PWMT), paw withdrawal thermal latency (PWTL) and paw circumference (PC); (2) the effect of chronic stress on the spontaneous paw-flinching reflex (SPFR), decrease in PWM, PWTL and increase in PC of the injected paw induced by BV. The results showed that (1) chronic restraint decreased significantly the PWMT and inhibited significantly the increase in PC, but had no effect on PWTL, compared with control group; (2) chronic restraint enhanced significantly BV-induced SPFR and inflammatory swelling of the injected paw. In a second series of experiments, the role of P2X7 receptor (P2X7R) in the enhancement of BV-induced inflammatory pain produced by chronic restraint stress was determined. Systemic pretreatment with P2X7R antagonist completely reversed the decrease in PWMT produced by chronic restraint, inhibited significantly the enhancement of BV-induced inflammatory pain produced by chronic restraint stress. Taken together, our data indicate that chronic restraint stress-enhanced nociception and inflammation in the BV pain model, possibly involving the P2X7R.

  1. Stress analysis of two-dimensional C/C composite components for HTGR's core restraint techanism

    International Nuclear Information System (INIS)

    Satoshi Hanawa; Taiju Shibata; Jyunya Sumita; Masahiro Ishihara; Tatsuo Iyoku; Kazuhiro Sawa

    2005-01-01

    Carbon fiber reinforced carbon matrix composite (C/C composite) is one of the most promising materials for HTGRs core components due to their high strength as well as high temperature resistibility. One of the most attractive applications of C/C composite is the core restraint mechanism. The core restraint mechanism is located around the reflector block and it works to tighten reactor core blocks so as to restrict un-supposition flow pass of coolant gas (bypass flow) in the core. The restriction of bypass flow reads to the high efficiency of coolant flow rate inside of the reactor core. For the future HTGRs and VHTR (Very High Temperature Reactor), it is important to develop the core restraint mechanism with C/C composite substitute for metallic materials as used for HTTR. For the application of C/C composite to core restraint mechanism, it is important to investigate the applicability of C/C composite in viewpoint of structural integrity. In the present study, supposing the application of 2D-C/C composite to core restraint mechanism, thermal stress behavior was analyzed by considering the thickness of the C/C composite and the gap between reflector block and core restraint. It was shown from the thermal stress analysis that the circumferential stress decreases with increasing the gap and that the restraint force increases with increasing the thickness. By optimizing the thickness of C/C composite and gap between reflector block and core restraint, the C/C composite is applicable to the core restraint mechanism. (authors)

  2. Software Safety Risk in Legacy Safety-Critical Computer Systems

    Science.gov (United States)

    Hill, Janice L.; Baggs, Rhoda

    2007-01-01

    Safety Standards contain technical and process-oriented safety requirements. Technical requirements are those such as "must work" and "must not work" functions in the system. Process-Oriented requirements are software engineering and safety management process requirements. Address the system perspective and some cover just software in the system > NASA-STD-8719.13B Software Safety Standard is the current standard of interest. NASA programs/projects will have their own set of safety requirements derived from the standard. Safety Cases: a) Documented demonstration that a system complies with the specified safety requirements. b) Evidence is gathered on the integrity of the system and put forward as an argued case. [Gardener (ed.)] c) Problems occur when trying to meet safety standards, and thus make retrospective safety cases, in legacy safety-critical computer systems.

  3. Practices, attitudes and perceptions toward road safety in yerevan, republic of armenia.

    Science.gov (United States)

    Chekijian, Sharon Anoush; Truzyan, Nune

    2012-01-01

    : To determine knowledge and attitudes regarding traffic safety devices, measures, and legislation in the general population in Yerevan, Republic of Armenia. : We conducted a baseline random digit dial fixed line telephone verbal survey of Yerevan households in April 2009 with a follow-up survey in May 2010. Survey domains included restraint use, motor vehicle crash experiences, and attitudes regarding traffic safety. : In the initial survey, of 2137 numbers dialed, 436 persons were reached and 390 (90%) agreed to participate. Of survey respondents, 90% percent of household cars had seatbelts, while 47% had airbags. Twenty-four percent always or usually wore a seatbelt when driving, 21% wore a belt as a passenger. 39% were unaware of child restraints. Of the 61% who were aware of child restraints, only 32% had ever used one. A follow-up survey was conducted one year later after enforcement efforts were increased. In the follow-up survey, 81% percent always or usually wore a seatbelt when driving, and 69% wore a belt as a passenger. There was no significant increase of awareness or use of child restraints in the follow-up survey. : Although cars in Yerevan have seat belts, the majority of drivers and passengers prior to the intervention did not use them. Knowledge and use of child restraints was poor. The follow-up survey conducted after an enforcement campaign was underway in Yerevan showed that improved enforcement greatly increased awareness and compliance with current legislation. This study provides vital baseline information for the formulation of future policy. It also highlights the need for a multi-dimensional road traffic safety initiative through public educational campaigns, enforcement of current laws, and development of novel prevention policies and regulations.

  4. Do organisational constraints explain the use of restraint? A comparative ethnographic study from three nursing homes in Norway.

    Science.gov (United States)

    Øye, Christine; Jacobsen, Frode Fadnes; Mekki, Tone Elin

    2017-07-01

    To investigate (1) what kind of restraint is used in three nursing homes in Norway and (2) how staff use restraint under what organisational conditions. Restraint use in residents living with dementia in nursing homes is controversial, and at odds with fundamental human rights. Restraint is a matter of hindering residents' free movement and will by applying either interactional, physical, medical, surveillance or environmental restraint. Previous research has identified use of restraint related to individual resident characteristics such as agitation, aggressiveness and wandering. This model is embedded in an overall mixed-method education intervention design study called Modelling and evaluating evidence-based continuing education program in dementia care (MEDCED), applying ethnography postintervention to examine the use of restraint in 24 nursing homes in Norway. Based on restraint diversity measured in the trial, ethnographic investigation was carried out in three different nursing homes in Norway over a 10-month period to examine restraint use in relation to organisational constraints. Several forms of restraint were observed; among them, interactional restraint was used most frequently. We identified that use of restraint relates to the characteristics of individual residents, such as agitation, aggressiveness and wandering. However, restraint use should also be explained in relation to organisational conditions such as resident mix, staff culture and available human resources. A fluctuating and dynamic interplay between different individual and contextual factors determines whether restraint is used - or not in particular situations with residents living with dementia. Educational initiatives targeting staff to reduce restraint must be sensitive towards fluctuating organisational constraints. © 2016 John Wiley & Sons Ltd.

  5. Nuclear component horizontal seismic restraint

    International Nuclear Information System (INIS)

    Snyder, G.J.

    1988-01-01

    In a nuclear reactor having a reactor vessel, a reactor guard vessel, a thermal insulation shell and a horizontal seismic restraint, a restraint is described comprising: a. a first ring on the wall of the reactor vessel; b. a second ring on the wall of the reactor guard vessel in alignment with the first ring; c. a first block attached to the second ring proximate the first ring so as to provide a predetermined clearance between the first block and the first ring which is reduced to zero during thermal expansion; d. motion limit means extending through an aperture in the thermal insulation shell in alignment with the second ring and the first block; the e. a second block attached to the motion limit means proximate the second ring and in alignment the first block so as to provide a predetermined clearance between the second block and the second ring which is reduced to zero during thermal expansion

  6. NASA System Safety Handbook. Volume 2: System Safety Concepts, Guidelines, and Implementation Examples

    Science.gov (United States)

    Dezfuli, Homayoon; Benjamin, Allan; Everett, Christopher; Feather, Martin; Rutledge, Peter; Sen, Dev; Youngblood, Robert

    2015-01-01

    This is the second of two volumes that collectively comprise the NASA System Safety Handbook. Volume 1 (NASASP-210-580) was prepared for the purpose of presenting the overall framework for System Safety and for providing the general concepts needed to implement the framework. Volume 2 provides guidance for implementing these concepts as an integral part of systems engineering and risk management. This guidance addresses the following functional areas: 1.The development of objectives that collectively define adequate safety for a system, and the safety requirements derived from these objectives that are levied on the system. 2.The conduct of system safety activities, performed to meet the safety requirements, with specific emphasis on the conduct of integrated safety analysis (ISA) as a fundamental means by which systems engineering and risk management decisions are risk-informed. 3.The development of a risk-informed safety case (RISC) at major milestone reviews to argue that the systems safety objectives are satisfied (and therefore that the system is adequately safe). 4.The evaluation of the RISC (including supporting evidence) using a defined set of evaluation criteria, to assess the veracity of the claims made therein in order to support risk acceptance decisions.

  7. 'Mechanical restraint-confounders, risk, alliance score'

    DEFF Research Database (Denmark)

    Deichmann Nielsen, Lea; Bech, Per; Hounsgaard, Lise

    2017-01-01

    . AIM: To clinically validate a new, structured short-term risk assessment instrument called the Mechanical Restraint-Confounders, Risk, Alliance Score (MR-CRAS), with the intended purpose of supporting the clinicians' observation and assessment of the patient's readiness to be released from mechanical...... restraint. METHODS: The content and layout of MR-CRAS and its user manual were evaluated using face validation by forensic mental health clinicians, content validation by an expert panel, and pilot testing within two, closed forensic mental health inpatient units. RESULTS: The three sub-scales (Confounders......, Risk, and a parameter of Alliance) showed excellent content validity. The clinical validations also showed that MR-CRAS was perceived and experienced as a comprehensible, relevant, comprehensive, and useable risk assessment instrument. CONCLUSIONS: MR-CRAS contains 18 clinically valid items...

  8. Mental health inpatients' and staff members' suggestions for reducing physical restraint: A qualitative study.

    Science.gov (United States)

    Wilson, C; Rouse, L; Rae, S; Kar Ray, M

    2018-04-01

    WHAT IS KNOWN ON THE SUBJECT?: Restraint has negative psychological, physical and relational consequences for mental health patients and staff. Restraint reduction interventions have been developed (e.g., "Safewards"). Limited qualitative research has explored suggestions on how to reduce physical restraint (and feasibility issues with implementing interventions) from those directly involved. WHAT DOES THIS PAPER ADD TO EXISTING KNOWLEDGE?: This paper explores mental health patients' and staff members' suggestions for reducing physical restraint, whilst addressing barriers to implementing these. Findings centred on four themes: improving communication and relationships; staffing factors; environment and space; and activities and distraction. Not all suggestions are addressed by currently available interventions. Barriers to implementation were identified, centring on a lack of time and/or resources; with the provision of more time for staff to spend with patients and implement interventions seen as essential to reducing physical restraint. WHAT ARE THE IMPLICATIONS FOR PRACTICE?: Improving communication and relationships between staff/patients, making staffing-related changes, improving ward environments and providing patient activities are central to restraint reduction in mental healthcare. Fundamental issues related to understaffing, high staff turnover, and lack of time and resources need addressing in order for suggestions to be successfully implemented. Introduction Physical restraint has negative consequences for all involved, and international calls for its reduction have emerged. Some restraint reduction interventions have been developed, but limited qualitative research explores suggestions on how to reduce physical restraint (and feasibility issues with implementation) from those directly involved. Aims To explore mental health patients' and staff members' suggestions for reducing physical restraint. Methods Interviews were conducted with 13 inpatients

  9. Car seat inspection among children older than 3 years: Using data to drive practice in child passenger safety.

    Science.gov (United States)

    Kroeker, Amber M; Teddy, Amy J; Macy, Michelle L

    2015-09-01

    Motor vehicle crashes are the leading cause of unintentional death and disability among children 4 years to 12 years of age in the United States. Despite the high risk of injury from motor vehicle crashes in this age group, parental awareness and child passenger safety programs in particular may lack focus on this age group. This is a retrospective cross-sectional analysis of child passenger safety seat checklist forms from two Safe Kids coalitions in Michigan (2013) to identify restraint type upon arrival to car seat inspections. Other variables were included if the coalition provided a new child safety seat and if the child had a sibling who underwent a car seat inspection. χ statistics were used to compare change in restraint use on arrival and at departure, the proportion of children attending a car seat inspection event by age, the age category of children by site, the proportion of children with siblings also undergoing a car seat inspection by age, and the distribution of a new child safety seat by age. Data were available from 1,316 Safe Kids Huron Valley and 3,215 Safe Kids Greater Grand Rapids car seat inspections. Just 10.8% of the total seats inspected were booster seats. Child safety seats for infant and young children were more commonly inspected (rear-facing carrier [40.3%], rear-facing convertible [10.2%], and forward-facing [19.3%] car seats). Few children at inspections used a seat belt only (5.4%) or had no restraint (13.8%). Children 4 years and older were found to be in a suboptimal restraint at least 30% of the time. Low proportions of parents use car seat inspections for children in the booster seat age group. The proportion of children departing the inspection in a more protective restraint increased with increasing age. This highlights an area of weakness in child passenger safety programs and signals an opportunity to strengthen efforts on The Booster Age Child. Epidemiologic/prognostic study, level III.

  10. A week of Israeli restraint

    NARCIS (Netherlands)

    Reinhart, T.

    2006-01-01

    In Israeli discourse, Israel is always the side exercising restraint in its conflict with the Palestinians. This was true again for the events of the past week: As the Qassam rockets were falling on the Southern Israeli town of Sderot, it was “leaked” that the Israeli Minister of Defense had

  11. 78 FR 4985 - Uniform Procedures for State Highway Safety Grant Programs

    Science.gov (United States)

    2013-01-23

    ...) that were tied to the agency's child restraint performance standards (FMVSS 213). Thus, under today's... consolidates into one rule a number of old regulations (State Highway Safety Agency, Political Subdivision... Belt Performance Grants (formerly codified at 23 U.S.C. 406) and Child Safety and Child Booster Seat...

  12. Reactor safety systems

    International Nuclear Information System (INIS)

    Kafka, P.

    1975-01-01

    The spectrum of possible accidents may become characterized by the 'maximum credible accident', which will/will not happen. Similary, the performance of safety systems in a multitude of situations is sometimes simplified to 'the emergency system will/will not work' or even 'reactors are/ are not safe'. In assessing safety, one must avoid this fallacy of reducing a complicated situation to the simple black-and-white picture of yes/no. Similarly, there is a natural tendency continually to improve the safety of a system to assure that it is 'safe enough'. Any system can be made safer and there is usually some additional cost. It is important to balance the increased safety against the increased costs. (orig.) [de

  13. Interactive effects of dietary restraint and adiposity on stress-induced eating and the food choice of children.

    Science.gov (United States)

    Roemmich, James N; Lambiase, Maya J; Lobarinas, Christina L; Balantekin, Katherine N

    2011-12-01

    The Individual Differences Model posits that individual differences in physiological and psychological factors explain eating behaviors in response to stress. The purpose was to determine the effects of individual differences in adiposity, dietary restraint and stress reactivity on children's energy intake and food choices. A total of 40 boys and girls, age 8-12 years, with wide ranges of dietary restraint, adiposity, and stress reactivity were measured for total energy intake and choice of energy dense 'comfort' and lower density 'healthy' foods following reading and speech stressor manipulations. When exploring the interaction of dietary restraint and stress reactivity, lower restraint/lower reactivity and lower restraint/higher reactivity were associated with reductions in energy intake (37-62 kcal) and comfort food (33-89 kcal). Higher restraint/lower reactivity was associated with consuming 86 fewer total kcal and 45 fewer kcal of comfort food. Only higher restraint/higher reactivity predicted increased energy intake (104 kcal) and comfort food (131 kcal). The interaction of dietary restraint and percentage body fat revealed that lower restraint/lower adiposity was associated with consuming 123 fewer kcal after being stressed with the entire reduction due to a decrease in comfort food. Lower restraint/higher adiposity was associated with consuming 116 kcal more after being stressed with 70% (81 kcal) of the increase in the form of comfort foods. Higher restraint/lower adiposity and higher restraint/higher adiposity were associated with smaller changes in total energy intake of 22 kcal and 1 kcal; respectively. Both restraint and adiposity moderated the effect of stress on energy intake and food choice. Children with greater adiposity may be at risk for stress-induced eating to contribute to their obesity. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Reactor system safety assurance

    International Nuclear Information System (INIS)

    Mattson, R.J.

    1984-01-01

    The philosophy of reactor safety is that design should follow established and conservative engineering practices, there should be safety margins in all modes of plant operation, special systems should be provided for accidents, and safety systems should have redundant components. This philosophy provides ''defense in depth.'' Additionally, the safety of nuclear power plants relies on ''safety systems'' to assure acceptable response to design basis events. Operating experience has shown the need to study plant response to more frequent upset conditions and to account for the influence of operators and non-safety systems on overall performance. Defense in depth is being supplemented by risk and reliability assessment

  15. Magnetic nuclear core restraint and control

    International Nuclear Information System (INIS)

    Cooper, M.H.

    1979-01-01

    A lateral restraint and control system for a nuclear reactor core adaptable to provide an inherent decrease of core reactivity in response to abnormally high reactor coolant fluid temperatures. An electromagnet is associated with structure for radially compressing the core during normal reactor conditions. A portion of the structures forming a magnetic circuit are composed of ferromagnetic material having a curie temperature corresponding to a selected coolant fluid temperature. Upon a selected signal, or inherently upon a preselected rise in coolant temperature, the magnetic force is decreased a given amount sufficient to relieve the compression force so as to allow core radial expansion. The expanded core configuration provides a decreased reactivity, tending to shut down the nuclear reaction

  16. [Vision on and use of physical restraints and 'smart technology' in nursing homes in Flanders].

    Science.gov (United States)

    Carlassara, V; Lampo, E; Degryse, B; Van Audenhove, C; Spruytte, N

    2017-04-01

    The STAFF-project investigates in what way 'smart technology' can offer an alternative for physical restraints in nursing homes. A survey is realized aimed at gaining more insight into the vision on and the use of physical restraints and 'smart technology'. Two partly overlapping structured questionnaires were developed and sent to nursing home staff in Flanders (Belgium). One hundred fifty six administrators (managers or assistant-managers) and 238 caregiving staff (nurses, nursing aids, paramedical staff and other) completed the online questionnaire. In general there is a low acceptability of physical restraint use, however, a more nuanced picture of acceptability is present depending on the specific motivation for using physical restraints and on the specific means of physical restraints. About half of the administrators say they use smart technology in the nursing home. The two main reasons for not applying (yet) smart technology are 'too high price for smart technology' and 'inadequate infrastructure of the nursing home'. All respondents underscore the importance of multiple strategies to diminish the use of physical restraints in nursing homes. Physical restraint use is a complex theme and needs a nuanced analysis and management. This study shows that there is still room for improvement in diminishing the use of physical restraints and that nursing homes in Flanders are open to use smart technology.

  17. The detrimental effects of physical restraint as a consequence for inappropriate classroom behavior.

    Science.gov (United States)

    Magee, S K; Ellis, J

    2001-01-01

    Functional analyses produced inconclusive results regarding variables that maintained problem behavior for 2 students with developmental disabilities. Procedures were modified to include a contingent physical restraint condition based on in-class observations. Results indicated that tinder conditions in which physical restraint (i.e., basket-hold timeout) was applied contingent on problem behavior, rates of these behaviors increased across sessions for both subjects. Implications for the use of physical restraint in the classroom are discussed.

  18. Effectiveness of a multifactorial intervention to reduce physical restraints in nursing home residents.

    Science.gov (United States)

    Koczy, Petra; Becker, Clemens; Rapp, Kilian; Klie, Thomas; Beische, Denis; Büchele, Gisela; Kleiner, Andrea; Guerra, Virginia; Rissmann, Ulrich; Kurrle, Susan; Bredthauer, Doris

    2011-02-01

    To evaluate the effectiveness of a multifactorial intervention to reduce the use of physical restraints in residents of nursing homes. Cluster-randomized controlled trial. Forty-five nursing homes in Germany. Three hundred thirty-three residents who were being restrained at the start of the intervention. Persons responsible for the intervention in the nursing homes attended a 6-hour training course that included education about the reasons restraints are used, the adverse effects, and alternatives to their use. Technical aids, such as hip protectors and sensor mats, were provided. The training was designed to give the change agents tools for problem-solving to prevent behavioral symptoms and injuries from falls without using physical restraints. The main outcome was the complete cessation of physical restraint use on 3 consecutive days 3 months after the start of the intervention. Secondary outcomes were partial reductions in restraint use, percentage of fallers, number of psychoactive drugs, and occurrence of behavioral symptoms. The probability of being unrestrained in the intervention group (IG) was more than twice that in the control group (CG) at the end of the study (odds ratio=2.16, 95% confidence interval=1.05-4.46). A partial reduction of restraint use was also about twice as often achieved in the IG as in the CG. No negative effect was observed regarding medication or behavioral symptoms. The percentage of fallers was higher in the IG. The intervention reduced restraint use without a significant increase in falling, behavioral symptoms, or medication. © 2011, Copyright the Authors. Journal compilation © 2011, The American Geriatrics Society.

  19. Dietary restraint partially mediates the relationship between impulsivity and binge eating only in lean individuals: The importance of accounting for body mass in studies of restraint

    Directory of Open Access Journals (Sweden)

    Jaime Ashley Coffino

    2016-10-01

    Full Text Available Binge eating is characteristic of eating and weight-related disorders such as binge eating disorder, bulimia nervosa, and obesity. In light of data that suggests impulsivity is associated with overeating specifically in restrained eaters, this study sought to elucidate the exact nature of the associations between these variables, hypothesizing that the relationship between impulsivity and binge eating is mediated by restrained eating. We further hypothesized that the role of dietary restraint as a mediator would be moderated by body mass index (BMI. Study participants (n = 506, 50.6% female were categorized based on self-reported BMI as under- and normal weight (BMI < 25, 65.8%, n = 333 or overweight and obese (BMI ≥ 25, 34.2%, n = 173 and completed the restrained eating subscale of the Dutch Eating Behavior Questionnaire, the difficulties with impulse control subscale of the Difficulties with Emotion Regulation Scale, and the Binge Eating Scale. Findings provide initial evidence for the hypothesized moderated mediation model, with dietary restraint partially mediating the relationship between impulsivity and binge eating severity only in lean respondents. In respondents with overweight or obesity, impulsivity was significantly correlated with binge eating severity, but dietary restraint was not. Findings inform our conceptualization of dietary restraint as a possible risk factor for binge eating and highlight the importance of accounting for body mass in research on the impact of dietary restraint on eating behaviors.

  20. Integration of Active and Passive Safety Technologies--A Method to Study and Estimate Field Capability.

    Science.gov (United States)

    Hu, Jingwen; Flannagan, Carol A; Bao, Shan; McCoy, Robert W; Siasoco, Kevin M; Barbat, Saeed

    2015-11-01

    The objective of this study is to develop a method that uses a combination of field data analysis, naturalistic driving data analysis, and computational simulations to explore the potential injury reduction capabilities of integrating passive and active safety systems in frontal impact conditions. For the purposes of this study, the active safety system is actually a driver assist (DA) feature that has the potential to reduce delta-V prior to a crash, in frontal or other crash scenarios. A field data analysis was first conducted to estimate the delta-V distribution change based on an assumption of 20% crash avoidance resulting from a pre-crash braking DA feature. Analysis of changes in driver head location during 470 hard braking events in a naturalistic driving study found that drivers' head positions were mostly in the center position before the braking onset, while the percentage of time drivers leaning forward or backward increased significantly after the braking onset. Parametric studies with a total of 4800 MADYMO simulations showed that both delta-V and occupant pre-crash posture had pronounced effects on occupant injury risks and on the optimal restraint designs. By combining the results for the delta-V and head position distribution changes, a weighted average of injury risk reduction of 17% and 48% was predicted by the 50th percentile Anthropomorphic Test Device (ATD) model and human body model, respectively, with the assumption that the restraint system can adapt to the specific delta-V and pre-crash posture. This study demonstrated the potential for further reducing occupant injury risk in frontal crashes by the integration of a passive safety system with a DA feature. Future analyses considering more vehicle models, various crash conditions, and variations of occupant characteristics, such as age, gender, weight, and height, are necessary to further investigate the potential capability of integrating passive and DA or active safety systems.

  1. A qualitative approach using the integrative model of behaviour change to identify intervention strategies to increase optimal child restraint practices among culturally and linguistically diverse families in New South Wales.

    Science.gov (United States)

    Brown, Julie; Burton, Danielle; Nikolin, Stevan; Crooks, Philippa Jane; Hatfield, Julie; Bilston, Lynne E

    2013-02-01

    To qualitatively explore barriers to optimal child restraint use using the integrative behaviour change model in culturally and linguistically diverse (CALD) communities in New South Wales (NSW), Australia. A semi-structured discussion was used to conduct 11 language specific focus groups in Arabic, Assyrian, Cantonese, Mandarin, Vietnamese and Turkish. Translated transcriptions were analysed using the major concepts of the integrative behaviour change model. Restraint use intent among CALD community carers is related to perceived safety of their children and complying with the law. While most participants appreciated the safety benefits of correct and appropriate use, a minority did not. Child restraint legislation may positively influence social norms, and enforcement appears to increase parental self-efficacy. However, concerns over child comfort may negatively influence both norms and self-efficacy. There are clear deficits in knowledge that may act as barriers as well as confusion over best practice in safely transporting children. Large family size, vehicle size and cost appear to be real environmental constraints in CALD communities. Determinants of intent and deficits in knowledge in this diverse range of CALD communities in NSW Australia are similar to those reported in other qualitative studies regardless of the population studied. This indicates that key messages should be the same regardless of the target population. However, for CALD communities there is a specific need to ensure access to detailed information through appropriate delivery strategies and languages. Furthermore, practical constraints such as cost of restraints and family size may be particularly important in CALD communities.

  2. Evaluation of ISO CRS Envelopes Relative to U.S. Vehicles and Child Restraint Systems.

    Science.gov (United States)

    Hu, Jingwen; Manary, Miriam A; Klinich, Kathleen D; Reed, Matthew P

    2015-01-01

    The objectives of this study are to use computer simulation to evaluate the International Organization for Standardization (ISO) 13216-3:2006(E) child restraint system (CRS) envelopes relative to rear seat compartments from vehicles and CRSs in the U.S. market, investigate the potential compatibility issues of U.S. vehicles and CRSs, and demonstrate whether necessary modifications can be made to introduce such a system into compatibility evaluations between U.S. vehicles and CRSs. Three-dimensional geometry models for 26 vehicles and 16 convertible CRS designs developed previously were used. Geometry models of 3 forward-facing and 3 rear-facing CRS envelopes provided by the ISO were built in the current study. The virtual fit process closely followed the physical procedures described in the ISO standards. The results showed that the current ISO rear-facing envelopes can provide reasonable classifications for CRSs and vehicles, but the forward-facing envelopes do not represent products currently in the U.S. market. In particular, all of the selected vehicles could accommodate the largest forward-facing CRS envelope at the second-row seat location behind the driver seat. In contrast, half of the selected CRSs could not fit within any of the forward-facing ISO CRS envelopes, mainly due to protrusion at the rear-top corner of the envelope. The results also indicate that the rear seat compartment in U.S. vehicles often cannot accommodate a large portion of convertible CRSs in the rear-facing position. The increased demand for vehicle fuel economy and the recommendation to keep children rear-facing longer may lead to smaller cars and larger CRSs, which may increase the potential for fit problems. The virtual classifications indicated that contact between the forward-facing CRSs and the head restraints in the rear seats as well as that between the rear-facing CRSs and the back of the front seats is a main concern regarding the compatibility between the vehicles and the

  3. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  4. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  5. Magnetic nuclear core restraint and control

    International Nuclear Information System (INIS)

    Cooper, M.H.

    1978-01-01

    Disclosed is a lateral restraint and control system for a nuclear reactor core adaptable to provide an inherent decrease of core reactivity in response to abnormally high reactor coolant fluid temperatures. An electromagnet is associated with structure for radially compressing the core during normal reactor conditions. A portion of the structures forming a magnetic circuit are composed of ferromagnetic material having a curie temperature corresponding to a selected coolant fluid temperature. Upon a selected signal, or inherently upon a preselected rise in coolant temperature, the magnetic force is decreased a given amount sufficient to relieve the compression force so as to allow core radial expansion. The expanded core configuration provides a decreased reactivity, tending to shut down the nuclear reaction

  6. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    Science.gov (United States)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  7. Applying sensory modulation to mental health inpatient care to reduce seclusion and restraint

    DEFF Research Database (Denmark)

    Andersen, Charlotte; Kolmos, Anne; Andersen, Kjeld

    2017-01-01

    that is associated with reduced rates of seclusion and restraint in mental healthcare, but there is need for more research in this area. AIMS: Using SM to reduce restraint and seclusion in inpatient mental health care. METHODS: The study included two similar psychiatric units where one unit implemented SM and one...... unit served as the control group. In the very beginning of the study, a staff-training program in the use of SM including assessment tools and intervention strategies was established. Data on restraint and forced medicine were sampled post the course of the year of implementation and compared...... with the control group. RESULTS: The use of belts decreased with 38% compared to the control group. The use of forced medication decreased with 46% compared to the control group. Altogether the use of physical restraint and forced medication decreased significantly with 42% (p 

  8. CLASSIFICATION OF RESTRAINTS IN THE OPTIMIZATION PROBLEM OF A COLD-FORMED PROFILE

    Directory of Open Access Journals (Sweden)

    Agnieszka Łukowicz

    2015-11-01

    Full Text Available This work describes the restraints in the optimization problem. This is an important and complicated issue because it requires taking into account a vast range of information related to the design and production. In order to describe the relations of a specific optimization problem, it is essential to adopt appropriate criteria and to collect information on all kinds of restraints, i.e. boundary conditions. The following paper verifies the various restraints and defines three subsets: design assumptions, technological limitations and standard conditions. The provided classification was made with reference to the analysis of the construction applicability of the newly patented cold-formed profile.

  9. Safety design guide for safety related systems for CANDU 9

    International Nuclear Information System (INIS)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young; A. C. D. Wright

    1996-03-01

    In general, two types of safety related systems and structures exist in the nuclear plant; The one is a systems and structures which perform safety functions during the normal operation of the plant, and the other is a systems and structures which perform safety functions to mitigate events caused by failure of the normally operating systems or by naturally occurring phenomena. In this safety design guide, these systems are identified in detail, and the major events for which the safety functions are required and the major safety requirements are identified in the list. As the probabilistic safety assessments are completed during the course of the project, additions or deletions to the list may be justified. 3 tabs. (Author) .new

  10. Safety design guide for safety related systems for CANDU 9

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Duk Su; Chang, Woo Hyun; Lee, Nam Young [Korea Atomic Energy Research Institute, Daeduk (Korea, Republic of); Wright, A.C.D. [Atomic Energy of Canada Ltd., Toronto (Canada)

    1996-03-01

    In general, two types of safety related systems and structures exist in the nuclear plant; The one is a systems and structures which perform safety functions during the normal operation of the plant, and the other is a systems and structures which perform safety functions to mitigate events caused by failure of the normally operating systems or by naturally occurring phenomena. In this safety design guide, these systems are identified in detail, and the major events for which the safety functions are required and the major safety requirements are identified in the list. As the probabilistic safety assessments are completed during the course of the project, additions or deletions to the list may be justified. 3 tabs. (Author) .new.

  11. Algorithm for selection of optimized EPR distance restraints for de novo protein structure determination

    Science.gov (United States)

    Kazmier, Kelli; Alexander, Nathan S.; Meiler, Jens; Mchaourab, Hassane S.

    2010-01-01

    A hybrid protein structure determination approach combining sparse Electron Paramagnetic Resonance (EPR) distance restraints and Rosetta de novo protein folding has been previously demonstrated to yield high quality models (Alexander et al., 2008). However, widespread application of this methodology to proteins of unknown structures is hindered by the lack of a general strategy to place spin label pairs in the primary sequence. In this work, we report the development of an algorithm that optimally selects spin labeling positions for the purpose of distance measurements by EPR. For the α-helical subdomain of T4 lysozyme (T4L), simulated restraints that maximize sequence separation between the two spin labels while simultaneously ensuring pairwise connectivity of secondary structure elements yielded vastly improved models by Rosetta folding. 50% of all these models have the correct fold compared to only 21% and 8% correctly folded models when randomly placed restraints or no restraints are used, respectively. Moreover, the improvements in model quality require a limited number of optimized restraints, the number of which is determined by the pairwise connectivities of T4L α-helices. The predicted improvement in Rosetta model quality was verified by experimental determination of distances between spin labels pairs selected by the algorithm. Overall, our results reinforce the rationale for the combined use of sparse EPR distance restraints and de novo folding. By alleviating the experimental bottleneck associated with restraint selection, this algorithm sets the stage for extending computational structure determination to larger, traditionally elusive protein topologies of critical structural and biochemical importance. PMID:21074624

  12. Choosing Staff Members Reduces Time in Mechanical Restraint Due to Self-Injurious Behaviour and Requesting Restraint

    Science.gov (United States)

    Jensen, Craig C.; Lydersen, Tore; Johnson, Paul R.; Weiss, Shannon R.; Marconi, Michael R.; Cleave, Mary L.; Weber, Patricia

    2012-01-01

    Background: Using mechanical restraints to protect a person who engaged in dangerous self-injury was decreased by manipulation of an establishing operation involving the client choosing the staff person who would work with her. Materials and Methods: The client was a 28-year-old woman diagnosed with autism, bipolar disorder, static cerebral…

  13. Safety system function trends

    International Nuclear Information System (INIS)

    Johnson, C.

    1989-01-01

    This paper describes research to develop risk-based indicators of plant safety performance. One measure of the safety-performance of operating nuclear power plants is the unavailability of important safety systems. Brookhaven National Laboratory and Science Applications International Corporation are evaluating ways to aggregate train-level or component-level data to provide such an indicator. This type of indicator would respond to changes in plant safety margins faster than the currently used indicator of safety system unavailability (i.e., safety system failures reported in licensee event reports). Trends in the proposed indicator would be one indication of trends in plant safety performance and maintenance effectiveness. This paper summarizes the basis for such an indicator, identifies technical issues to be resolved, and illustrates the potential usefullness of such indicators by means of computer simulations and case studies

  14. Intrinsic brain subsystem associated with dietary restraint, disinhibition and hunger: an fMRI study.

    Science.gov (United States)

    Zhao, Jizheng; Li, Mintong; Zhang, Yi; Song, Huaibo; von Deneen, Karen M; Shi, Yinggang; Liu, Yijun; He, Dongjian

    2017-02-01

    Eating behaviors are closely related to body weight, and eating traits are depicted in three dimensions: dietary restraint, disinhibition, and hunger. The current study aims to explore whether these aspects of eating behaviors are related to intrinsic brain activation, and to further investigate the relationship between the brain activation relating to these eating traits and body weight, as well as the link between function connectivity (FC) of the correlative brain regions and body weight. Our results demonstrated positive associations between dietary restraint and baseline activation of the frontal and the temporal regions (i.e., food reward encoding) and the limbic regions (i.e., homeostatic control, including the hypothalamus). Disinhibition was positively associated with the activation of the frontal motivational system (i.e., OFC) and the premotor cortex. Hunger was positively related to extensive activations in the prefrontal, temporal, and limbic, as well as in the cerebellum. Within the brain regions relating to dietary restraint, weight status was negatively correlated with FC of the left middle temporal gyrus and left inferior temporal gyrus, and was positively associated with the FC of regions in the anterior temporal gyrus and fusiform visual cortex. Weight status was positively associated with the FC within regions in the prefrontal motor cortex and the right ACC serving inhibition, and was negatively related with the FC of regions in the frontal cortical-basal ganglia-thalamic circuits responding to hunger control. Our data depicted an association between intrinsic brain activation and dietary restraint, disinhibition, and hunger, and presented the links of their activations and FCs with weight status.

  15. Optimising product advice based on age when design criteria are based on weight: child restraints in vehicles.

    Science.gov (United States)

    Anderson, R W G; Hutchinson, T P

    2009-03-01

    The motivation for this paper is the high rate of inappropriate child restraint selection in cars that is apparent in published surveys of child restraint use and how the public health messages promoting child restraints might respond. Advice has increasingly been given solely according to the child's weight, while many parents do not know the weight of their children. A common objection to promoting restraint use based on the age of the child is the imprecision of such advice, given the variation in the size of children, but the magnitude of the misclassification such advice would produce has never been estimated. This paper presents a method for estimating the misclassification of children by weight, when advice is posed in terms of age, and applies it to detailed child growth data published by the Centers for Disease Control and Prevention. In Australia, guidelines instructing all parents to promote their children from an infant restraint to a forward-facing child seat at 6 months, and then to a belt-positioning booster at 4 years, would mean that 5% of all children under the age of 6 years would be using a restraint not suited to their weight. Coordination of aged-based advice and the weight ranges chosen for the Australian Standard on child restraints could reduce this level of misclassification to less than 1%. The general method developed may also be applied to other aspects of restraint design that are more directly relevant to good restraint fit.

  16. Educational intervention on physical restraint use in long-term care facilities - Systematic review and meta-analysis.

    Science.gov (United States)

    Lan, Shao-Huan; Lu, Li-Chin; Lan, Shou-Jen; Chen, Jong-Chen; Wu, Wen-Jun; Chang, Shen-Peng; Lin, Long-Yau

    2017-08-01

    "Physical restraint" formerly used as a measure of protection for psychiatric patients is now widely used. However, existing studies showed that physical restraint not only has inadequate effect of protection but also has negative effects on residents. To analyzes the impact of educational program on the physical restraint use in long-term care facilities. A systematic review with meta-analysis and meta-regression. Eight databases, including Cochrane Library, ProQuest, PubMed, EMBASE, EBSCO, Web of Science, Ovid Medline and Physiotherapy Evidence Database (PEDro), were searched up to January 2017. Eligible studies were classified by intervention and accessed for quality using the Quality Assessment Tool for quantitative studies. Sixteen research articles were eligible in the final review; 10 randomize control trail studies were included in the analysis. The meta-analysis revealed that the use of physical restraint was significantly less often in the experimental (education) group (OR = 0.55, 95% CI: 0.39 to 0.78, p education would have decreased the effect of the restraint educational program (β: 0.08, p = 0.002); instead, the longer education period and more times of education would have a stronger effect of reducing the use of physical restraint (β: -0.07, p educational program had an effect on the reduced use of physical restraint. The results of meta-regression suggest that long-term care facilities should provide a continuous education program of physical restraint for caregivers. Copyright © 2017. Published by Elsevier Taiwan.

  17. IAEA Safety Standards on Management Systems and Safety Culture

    International Nuclear Information System (INIS)

    Persson, Kerstin Dahlgren

    2007-01-01

    The IAEA has developed a new set of Safety Standard for applying an integrated Management System for facilities and activities. The objective of the new Safety Standards is to define requirements and provide guidance for establishing, implementing, assessing and continually improving a Management System that integrates safety, health, environmental, security, quality and economic related elements to ensure that safety is properly taken into account in all the activities of an organization. With an integrated approach to management system it is also necessary to include the aspect of culture, where the organizational culture and safety culture is seen as crucial elements of the successful implementation of this management system and the attainment of all the goals and particularly the safety goals of the organization. The IAEA has developed a set of service aimed at assisting it's Member States in establishing. Implementing, assessing and continually improving an integrated management system. (author)

  18. Pasireotide treatment does not modify hyperglycemic and corticosterone acute restraint stress responses in rats.

    Science.gov (United States)

    Ribeiro-Oliveira, Antônio; Schweizer, Junia R O L; Amaral, Pedro H S; Bizzi, Mariana F; Silveira, Warley Cezar da; Espirito-Santo, Daniel T A; Zille, Giancarlo; Soares, Beatriz S; Schmid, Herbert A; Yuen, Kevin C J

    2018-04-17

    Pasireotide is a new-generation somatostatin analog that acts through binding to multiple somatostatin receptor subtypes. Studies have shown that pasireotide induces hyperglycemia, reduces glucocorticoid secretion, alters neurotransmission, and potentially affects stress responses typically manifested as hyperglycemia and increased corticosterone secretion. This study specifically aimed to evaluate whether pasireotide treatment modifies glucose and costicosterone secretion in response to acute restraint stress. Male Holtzman rats of 150-200 g were treated with pasireotide (10 µg/kg/day) twice-daily for two weeks or vehicle for the same period. Blood samples were collected at baseline and after 5, 10, 30, and 60 min of restraint stress. The three experimental groups comprised of vehicle + restraint (VEHR), pasireotide + restraint (PASR), and pasireotide + saline (PASNR). Following pasireotide treatment, no significant differences in baseline glucose and corticosterone levels were observed among the three groups. During restraint, hyperglycemia was observed at 10 min (p stressed groups when compared to the non-stressed PASNR group (p stressed groups at 5 min (p stressed PASNR group (p stress responses, thus preserving acute stress regulation.

  19. A daily diary study of perceived social isolation, dietary restraint, and negative affect in binge eating.

    Science.gov (United States)

    Mason, Tyler B; Heron, Kristin E; Braitman, Abby L; Lewis, Robin J

    2016-02-01

    Negative affect and dietary restraint are key predictors of binge eating, yet less is known about the impact of social factors on binge eating. The study sought to replicate and extend research on the relationships between negative affect, dietary restraint, perceived social isolation and binge eating using a daily diary methodology. College women (N = 54) completed measures of dietary restraint, negative affect, perceived social isolation, and binge eating daily for 14 days. Participants completed the measures nightly each day. A series of generalized estimating equations showed that dietary restraint was associated with less binge eating while controlling for negative affect and for perceived social isolation separately. Negative affect and perceived social isolation were associated with greater binge eating while controlling for restraint in separate analyses, but only perceived social isolation was significant when modeled simultaneously. All two-way interactions between negative affect, dietary restraint, and perceived social isolation predicting binge eating were nonsignificant. This study furthers our understanding of predictors of binge eating in a nonclinical sample. Specifically, these data suggest perceived social isolation, negative affect, and dietary restraint are important variables associated with binge eating in daily life and warrant further research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Pasung: Physical restraint and confinement of the mentally ill in the community

    Directory of Open Access Journals (Sweden)

    Diatri Hervita

    2008-06-01

    Full Text Available Abstract Background Physical restraint and confinement (pasung by families of people with mental illness is known to occur in many parts of the world but has attracted limited investigation. This preliminary observational study was carried out on Samosir Island in Sumatra, Indonesia, to investigate the nature of such restraint and confinement, the clinical characteristics of people restrained, and the reasons given by families and communities for applying such restraint. Methods The research method was cross-sectional observational research in a natural setting, carried out during a six-month period of working as the only psychiatrist in a remote district. Results Fifteen cases of pasung, approximately even numbers of males and females and almost all with a diagnosis of schizophrenia were identified. Duration of restraint ranged from two to 21 years. Discussion and Conclusion The provision of basic community mental health services, where there were none before, enabled the majority of the people who had been restrained to receive psychiatric treatment and to be released from pasung.

  1. Safety logic systems of PFBR

    International Nuclear Information System (INIS)

    Sambasivan, S. Ilango

    2004-01-01

    Full text : PFBR is provided with two independent, fast acting and diverse shutdown systems to detect any abnormalities and to initiate safety action. Each system consists of sensors, signal processing systems, logics, drive mechanisms and absorber rods. The absorber rods of the first system are Control and Safety Rods (CSR) and that of the second are called as Diverse Safety Rods (DSR). There are nine CSR and three DSR. While CSR are used for startup, control of reactor power, controlled shutdown and SCRAM, the DSR are used only for SCRAM. The respective drive mechanisms are called as CSRDM and DSRDM. Each of these two systems is capable of executing the shutdown satisfactorily with single failure criteria. Two independent safety logic systems based on diverse principles have been designed for the two shut down systems. The analog outputs of the sensors of Core Monitoring Systems comprising of reactor flux monitoring, core temperature monitoring, failed fuel detection and core flow monitoring systems are processed and converted into binary signals depending on their instantaneous values. Safety logic systems receive the binary signals from these core-monitoring systems and process them logically to protect the reactor against postulated initiating events. Neutronic and power to flow (P/Q) signals form the inputs to safety logic system-I and temperature signals are inputs to the safety logic system II. Failed fuel detection signals are processed by both the shut down systems. The two logic systems to actuate the safety rods are also based on two diverse designs and implemented with solid-state devices to meet all the requirements of safety systems. Safety logic system I that caters to neutronic and P/Q signals is designed around combinational logic and has an on-line test facility to detect struck at faults. The second logic system is based on dynamic logic and hence is inherently safe. This paper gives an overview of the two logic systems that have been

  2. Exploring perspectives on restraint during medical procedures in paediatric care: a qualitative interview study with nurses and physicians.

    Science.gov (United States)

    Svendsen, Edel Jannecke; Pedersen, Reidar; Moen, Anne; Bjørk, Ida Torunn

    2017-12-01

    The aim of this study was to explore nurses' and physicians' perspectives on and reasoning about the use of restraint during medical procedures on newly admitted preschoolers in somatic hospital care. We analysed qualitative data from individual interviews with a video recall session at the end with seven physicians and eight nurses. They had earlier participated in video recorded peripheral vein cannulations on preschool children. The data were collected between May 2012 and May 2013 at a paediatric hospital unit in Norway. The analysis resulted in three main themes: (1) disparate views on the concept of restraint and restraint use (2), ways to limit the use of physical restraint and its negative consequences, and (3) experience with the role of parents and their influence on restraint. Perspectives from both healthcare professions were represented in all the main themes and had many similarities. The results of this study may facilitate more informed and reflective discussions of restraint and contribute to higher awareness of restraint in clinical practice. Lack of guidance and scientific attention to restraint combined with conflicting interests and values among healthcare providers may result in insecurity, individual dogmatism, and a lack of shared discussions, language, and terminology.

  3. Restraint status improves the predictive value of motor vehicle crash criteria for pediatric trauma team activation.

    Science.gov (United States)

    Bozeman, Andrew P; Dassinger, Melvin S; Recicar, John F; Smith, Samuel D; Rettiganti, Mallikarjuna R; Nick, Todd G; Maxson, Robert T

    2012-12-01

    Most trauma centers incorporate mechanistic criteria (MC) into their algorithm for trauma team activation (TTA). We hypothesized that characteristics of the crash are less reliable than restraint status in predicting significant injury and the need for TTA. We identified 271 patients (age, <15 y) admitted with a diagnosis of motor vehicle crash. Mechanistic criteria and restraint status of each patient were recorded. Both MC and MC plus restraint status were evaluated as separate measures for appropriately predicting TTA based on treatment outcomes and injury scores. Improper restraint alone predicted a need for TTA with an odds ratios of 2.69 (P = .002). MC plus improper restraint predicted the need for TTA with an odds ratio of 2.52 (P = .002). In contrast, the odds ratio when using MC alone was 1.65 (P = .16). When the 5 MC were evaluated individually as predictive of TTA, ejection, death of occupant, and intrusion more than 18 inches were statistically significant. Improper restraint is an independent predictor of necessitating TTA in this single-institution study. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Fabrication of a small animal restraint for synchrotron biomedical imaging using a rapid prototyper

    International Nuclear Information System (INIS)

    Zhu Ying; Zhang Honglin; McCrea, Richard; Bewer, Brian; Wiebe, Sheldon; Nichol, Helen; Ryan, Christopher; Wysokinski, Tomasz; Chapman, Dean

    2007-01-01

    Biomedical research at synchrotron facilities may involve imaging live animals that must remain motionless for extended periods of time to obtain quality images. Even breathing movements reduce image quality but on the other hand excessive restraint of animals increases morbidity and mortality. We describe a humane animal restraint designed to eliminate head movements while promoting animal survival. This paper describes how an animal restraint that conforms to the shape of an animal's head was fabricated by a 3D prototyper. The method used to translate medical computed tomography (CT) data to a 3D stereolithography format is described and images of its use at the Canadian Light Source (CLS) are shown. This type of restraint holds great promise in improving image quality and repeatability while reducing stress on experimental animals

  5. The use of restraints in psychiatric patients

    African Journals Online (AJOL)

    2009-09-17

    Sep 17, 2009 ... In South Africa, according to the Mental Health Care Act No. 17 of 2002 .... and staff composition, type of ward and ward atmosphere. The type of ... (e.g. psychiatric diagnosis, strengths, family history), and restraint should be ...

  6. Safety of mechanical devices. Safety of automation systems

    International Nuclear Information System (INIS)

    Pahl, G.; Schweizer, G.; Kapp, K.

    1985-01-01

    The paper deals with the classic procedures of safety engineering in the sectors mechanical engineering, electrical and energy engineering, construction and transport, medicine technology and process technology. Particular stress is laid on the safety of automation systems, control technology, protection of mechanical devices, reactor safety, mechanical constructions, transport systems, railway signalling devices, road traffic and protection at work in chemical plans. (DG) [de

  7. Geometrically Nonlinear Transient Response of Laminated Plates with Nonlinear Elastic Restraints

    Directory of Open Access Journals (Sweden)

    Shaochong Yang

    2017-01-01

    Full Text Available To investigate the dynamic behavior of laminated plates with nonlinear elastic restraints, a varied constraint force model and a systematic numerical procedure are presented in this work. Several kinds of typical relationships of force-displacement for spring are established to simulate the nonlinear elastic restraints. In addition, considering the restraining moments of flexible pads, the pads are modeled by translational and rotational springs. The displacement- dependent constraint forces are added to the right-hand side of equations of motion and treated as additional applied loads. These loads can be explicitly defined, via an independent set of nonlinear load functions. The time histories of transverse displacements at typical points of the laminated plate are obtained through the transient analysis. Numerical examples show that the present method can effectively treat the geometrically nonlinear transient response of plates with nonlinear elastic restraints.

  8. Bupleurum falcatum prevents depression and anxiety-like behaviors in rats exposed to repeated restraint stress.

    Science.gov (United States)

    Lee, Bombi; Yun, Hye-Yeon; Shim, Insop; Lee, Hyejung; Hahm, Dae-Hyun

    2012-03-01

    Previous studies have demonstrated that repeated restraint stress in rodents produces increases in depression and anxietylike behaviors and alters the expression of corticotrophinreleasing factor (CRF) in the hypothalamus. The current study focused on the impact of Bupleurum falcatum (BF) extract administration on repeated restraint stress-induced behavioral responses using the forced swimming test (FST) and elevated plus maze (EPM) test. Immunohistochemical examinations of tyrosine hydroxylase (TH) expression in rat brain were also conducted. Male rats received daily doses of 20, 50, or 100 mg/kg (i.p.) BF extract for 15 days, 30 min prior to restraint stress (4 h/day). Hypothalamicpituitary- adrenal axis activation in response to repeated restraint stress was confirmed base on serum corticosterone levels and CRF expression in the hypothalamus. Animals that were pre-treated with BF extract displayed significantly reduced immobility in the FST and increased open-arm exploration in the EPM test in comparison with controls. BF also blocked the increase in TH expression in the locus coeruleus of treated rats that experienced restraint stress. Together, these results demonstrate that BF extract administration prior to restraint stress significantly reduces depression and anxiety-like behaviors, possibly through central adrenergic mechanisms, and they suggest a role for BF extract in the treatment of depression and anxiety disorders.

  9. Standardized error severity score (ESS) ratings to quantify risk associated with child restraint system (CRS) and booster seat misuse.

    Science.gov (United States)

    Rudin-Brown, Christina M; Kramer, Chelsea; Langerak, Robin; Scipione, Andrea; Kelsey, Shelley

    2017-11-17

    Although numerous research studies have reported high levels of error and misuse of child restraint systems (CRS) and booster seats in experimental and real-world scenarios, conclusions are limited because they provide little information regarding which installation issues pose the highest risk and thus should be targeted for change. Beneficial to legislating bodies and researchers alike would be a standardized, globally relevant assessment of the potential injury risk associated with more common forms of CRS and booster seat misuse, which could be applied with observed error frequency-for example, in car seat clinics or during prototype user testing-to better identify and characterize the installation issues of greatest risk to safety. A group of 8 leading world experts in CRS and injury biomechanics, who were members of an international child safety project, estimated the potential injury severity associated with common forms of CRS and booster seat misuse. These injury risk error severity score (ESS) ratings were compiled and compared to scores from previous research that had used a similar procedure but with fewer respondents. To illustrate their application, and as part of a larger study examining CRS and booster seat labeling requirements, the new standardized ESS ratings were applied to objective installation performance data from 26 adult participants who installed a convertible (rear- vs. forward-facing) CRS and booster seat in a vehicle, and a child test dummy in the CRS and booster seat, using labels that only just met minimal regulatory requirements. The outcome measure, the risk priority number (RPN), represented the composite scores of injury risk and observed installation error frequency. Variability within the sample of ESS ratings in the present study was smaller than that generated in previous studies, indicating better agreement among experts on what constituted injury risk. Application of the new standardized ESS ratings to installation

  10. Restraint stress and social defeat: What they have in common.

    Science.gov (United States)

    Motta, Simone Cristina; Canteras, Newton Sabino

    2015-07-01

    Bob Blanchard was a great inspiration for our studies on the neural basis of social defense. In the present study, we compared the hypothalamic pattern of activation between social defeat and restraint stress. As important stress situations, both defeated and immobilized animals displayed a substantial increase in Fos in the parvicellular part of the paraventricular nucleus,mostly in the region that contains the CRH neurons. In addition, socially defeated animals, but not restrained animals, recruited elements of the medial hypothalamic conspecific-responsive circuit, a region also engaged in other forms of social behavior. Of particular interest, both defeated and immobilized animals presented a robust increase in Fos expression in specific regions of the lateral hypothalamic area (i.e., juxtaparaventricular and juxtadorsomedial regions) likely to convey septo-hippocampal information encoding the environmental boundary restriction observed in both forms of stress, and in the dorsomedial part of the dorsal premammillary nucleus which seems to work as a key player for the expression of, at least, part of the behavioral responses during both restraint and social defeat. These results indicate interesting commonalities between social defeat and restraint stress, suggesting, for the first time, a septo-hippocampal–hypothalamic path likely to respond to the environmental boundary restriction that may act as common stressor component for both types of stress. Moreover, the comparison of the neural circuits mediating physical restraint and social defense revealed a possible path for encoding the entrapment component during social confrontation.

  11. Physical restraint use among nursing home residents: A comparison of two data collection methods

    Directory of Open Access Journals (Sweden)

    Voyer Philippe

    2004-10-01

    Full Text Available Abstract Background In view of the issues surrounding physical restraint use, it is important to have a method of measurement as valid and reliable as possible. We determined the sensitivity and specificity of physical restraint use a reported by nursing staff and b reviewed from medical and nursing records in nursing home settings, by comparing these methods with direct observation. Methods We sampled eight care units in skilled nursing homes, seven care units in nursing homes and one long-term care unit in a hospital, from eight facilities which included 28 nurses and 377 residents. Physical restraint use was assessed the day following three periods of direct observation by two different means: interview with one or several members of the regular nursing staff, and review of medical and nursing records. Sensitivity and specificity values were calculated according to 2-by-2 contingency tables. Differences between the methods were assessed using the phi coefficient. Other information collected included: demographic characteristics, disruptive behaviors, body alignment problems, cognitive and functional skills. Results Compared to direct observation (gold standard, reported restraint use by nursing staff yielded a sensitivity of 87.4% at a specificity of 93.7% (phi = 0.84. When data was reviewed from subjects' medical and nursing records, sensitivity was reduced to 74.8%, and specificity to 86.3% (phi = 0.54. Justifications for restraint use including risk for falls, agitation, body alignment problems and aggressiveness were associated with the use of physical restraints. Conclusions The interview of nursing staff and the review of medical and nursing records are both valid and reliable techniques for measuring physical restraint use among nursing home residents. Higher sensitivity and specificity values were achieved when nursing staff was interviewed as compared to reviewing medical records. This study suggests that the interview of nursing

  12. A protocol for the refinement of NMR structures using simultaneously pseudocontact shift restraints from multiple lanthanide ions

    Energy Technology Data Exchange (ETDEWEB)

    Sala, Davide; Giachetti, Andrea; Luchinat, Claudio, E-mail: luchinat@cerm.unifi.it; Rosato, Antonio, E-mail: rosato@cerm.unifi.it [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2016-11-15

    The binding of paramagnetic metal ions to proteins produces a number of different effects on the NMR spectra of the system. In particular, when the magnetic susceptibility of the metal ion is anisotropic, pseudocontact shifts (PCSs) arise and can be easily measured. They constitute very useful restraints for the solution structure determination of metal-binding proteins. In this context, there has been great interest in the use of lanthanide(III) ions to induce PCSs in diamagnetic proteins, e.g. through the replacement native calcium(II) ions. By preparing multiple samples in each of which a different ion of the lanthanide series is introduced, it is possible to obtain multiple independent PCS datasets that can be used synergistically to generate protein structure ensembles (typically called bundles). For typical NMR-based determination of protein structure, it is necessary to perform an energetic refinement of such initial bundles to obtain final structures whose geometric quality is suitable for deposition in the PDB. This can be conveniently done by using restrained molecular dynamics simulations (rMD) in explicit solvent. However, there are no available protocols for rMD using multiple PCS datasets as part of the restraints. In this work, we extended the PCS module of the AMBER MD package to handle multiple datasets and tuned a previously developed protocol for NMR structure refinement to achieve consistent convergence with PCS restraints. Test calculations with real experimental data show that this new implementation delivers the expected improvement of protein geometry, resulting in final structures that are of suitable quality for deposition. Furthermore, we observe that also initial structures generated only with traditional restraints can be successfully refined using traditional and PCS restraints simultaneously.

  13. Evaluating safety management system implementation

    International Nuclear Information System (INIS)

    Preuss, M.

    2009-01-01

    Canada is committed to not only maintaining, but also improving upon our record of having one of the safest aviation systems in the world. The development, implementation and maintenance of safety management systems is a significant step towards improving safety performance. Canada is considered a world leader in this area and we are fully engaged in implementation. By integrating risk management systems and business practices, the aviation industry stands to gain better safety performance with less regulatory intervention. These are important steps towards improving safety and enhancing the public's confidence in the safety of Canada's aviation system. (author)

  14. Exploiting structure similarity in refinement: automated NCS and target-structure restraints in BUSTER

    Energy Technology Data Exchange (ETDEWEB)

    Smart, Oliver S., E-mail: osmart@globalphasing.com; Womack, Thomas O.; Flensburg, Claus; Keller, Peter; Paciorek, Włodek; Sharff, Andrew; Vonrhein, Clemens; Bricogne, Gérard [Global Phasing Ltd, Sheraton House, Castle Park, Cambridge CB3 0AX (United Kingdom)

    2012-04-01

    Local structural similarity restraints (LSSR) provide a novel method for exploiting NCS or structural similarity to an external target structure. Two examples are given where BUSTER re-refinement of PDB entries with LSSR produces marked improvements, enabling further structural features to be modelled. Maximum-likelihood X-ray macromolecular structure refinement in BUSTER has been extended with restraints facilitating the exploitation of structural similarity. The similarity can be between two or more chains within the structure being refined, thus favouring NCS, or to a distinct ‘target’ structure that remains fixed during refinement. The local structural similarity restraints (LSSR) approach considers all distances less than 5.5 Å between pairs of atoms in the chain to be restrained. For each, the difference from the distance between the corresponding atoms in the related chain is found. LSSR applies a restraint penalty on each difference. A functional form that reaches a plateau for large differences is used to avoid the restraints distorting parts of the structure that are not similar. Because LSSR are local, there is no need to separate out domains. Some restraint pruning is still necessary, but this has been automated. LSSR have been available to academic users of BUSTER since 2009 with the easy-to-use -autoncs and @@target target.pdb options. The use of LSSR is illustrated in the re-refinement of PDB entries http://scripts.iucr.org/cgi-bin/cr.cgi?rm, where -target enables the correct ligand-binding structure to be found, and http://scripts.iucr.org/cgi-bin/cr.cgi?rm, where -autoncs contributes to the location of an additional copy of the cyclic peptide ligand.

  15. System Design and the Safety Basis

    International Nuclear Information System (INIS)

    Ellingson, Darrel

    2008-01-01

    The objective of this paper is to present the Bechtel Jacobs Company, LLC (BJC) Lessons Learned for system design as it relates to safety basis documentation. BJC has had to reconcile incomplete or outdated system description information with current facility safety basis for a number of situations in recent months. This paper has relevance in multiple topical areas including documented safety analysis, decontamination and decommissioning (D and D), safety basis (SB) implementation, safety and design integration, potential inadequacy of the safety analysis (PISA), technical safety requirements (TSR), and unreviewed safety questions. BJC learned that nuclear safety compliance relies on adequate and well documented system design information. A number of PIS As and TSR violations occurred due to inadequate or erroneous system design information. As a corrective action, BJC assessed the occurrences caused by systems design-safety basis interface problems. Safety systems reviewed included the Molten Salt Reactor Experiment (MSRE) Fluorination System, K-1065 fire alarm system, and the K-25 Radiation Criticality Accident Alarm System. The conclusion was that an inadequate knowledge of system design could result in continuous non-compliance issues relating to nuclear safety. This was especially true with older facilities that lacked current as-built drawings coupled with the loss of 'historical knowledge' as personnel retired or moved on in their careers. Walkdown of systems and the updating of drawings are imperative for nuclear safety compliance. System design integration with safety basis has relevance in the Department of Energy (DOE) complex. This paper presents the BJC Lessons Learned in this area. It will be of benefit to DOE contractors that manage and operate an aging population of nuclear facilities

  16. Contribution of social isolation, restraint, and hindlimb unloading to changes in hemodynamic parameters and motion activity in rats.

    Directory of Open Access Journals (Sweden)

    Darya Tsvirkun

    Full Text Available The most accepted animal model for simulation of the physiological and morphological consequences of microgravity on the cardiovascular system is one of head-down hindlimb unloading. Experimental conditions surrounding this model include not only head-down tilting of rats, but also social and restraint stresses that have their own influences on cardiovascular system function. Here, we studied levels of spontaneous locomotor activity, blood pressure, and heart rate during 14 days under the following experimental conditions: cage control, social isolation in standard rat housing, social isolation in special cages for hindlimb unloading, horizontal attachment (restraint, and head-down hindlimb unloading. General activity and hemodynamic parameters were continuously monitored in conscious rats by telemetry. Heart rate and blood pressure were both evaluated during treadmill running to reveal cardiovascular deconditioning development as a result of unloading. The main findings of our work are that: social isolation and restraint induced persistent physical inactivity, while unloading in rats resulted in initial inactivity followed by normalization and increased locomotion after one week. Moreover, 14 days of hindlimb unloading showed significant elevation of blood pressure and slight elevation of heart rate. Hemodynamic changes in isolated and restrained rats largely reproduced the trends observed during unloading. Finally, we detected no augmentation of tachycardia during moderate exercise in rats after 14 days of unloading. Thus, we concluded that both social isolation and restraint, as an integral part of the model conditions, contribute essentially to cardiovascular reactions during head-down hindlimb unloading, compared to the little changes in the hydrostatic gradient.

  17. Safety Information System Guide

    International Nuclear Information System (INIS)

    Bullock, M.G.

    1977-03-01

    This Guide provides guidelines for the design and evaluation of a working safety information system. For the relatively few safety professionals who have already adopted computer-based programs, this Guide may aid them in the evaluation of their present system. To those who intend to develop an information system, it will, hopefully, inspire new thinking and encourage steps towards systems safety management. For the line manager who is working where the action is, this Guide may provide insight on the importance of accident facts as a tool for moving ideas up the communication ladder where they will be heard and acted upon; where what he has to say will influence beneficial changes among those who plan and control his operations. In the design of a safety information system, it is suggested that the safety manager make friends with a computer expert or someone on the management team who has some feeling for, and understanding of, the art of information storage and retrieval as a new and better means for communication

  18. Mixed selection. Effects of body images, dietary restraint, and persuasive messages on females' orientations towards chocolate.

    Science.gov (United States)

    Durkin, Kevin; Hendry, Alana; Stritzke, Werner G K

    2013-01-01

    Many women experience ambivalent reactions to chocolate: craving it but also wary of its impact on weight and health. Chocolate advertisements often use thin ideal models and previous research indicates that this exacerbates ambivalence. This experiment compared attitudes to, and consumption of, chocolate following exposure to images containing thin or overweight models together with written messages that were either positive or negative about eating chocolate. Participants (all female) were categorised as either low- or high-restraint. Approach, avoidance and guilt motives towards chocolate were measured and the participants had an opportunity to consume chocolate. Exposure to thin ideal models led to higher approach motives and this effect was most marked among the high restraint participants. Avoidance and guilt scores did not vary as a function of model size or message, but there were clear differences between the restraint groups, with the high restraint participants scoring substantially higher than low restraint participants on both of these measures. When the participants were provided with an opportunity to eat some chocolate, those with high restraint who had been exposed to the thin models consumed the most. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. Architecture Level Safety Analyses for Safety-Critical Systems

    Directory of Open Access Journals (Sweden)

    K. S. Kushal

    2017-01-01

    Full Text Available The dependency of complex embedded Safety-Critical Systems across Avionics and Aerospace domains on their underlying software and hardware components has gradually increased with progression in time. Such application domain systems are developed based on a complex integrated architecture, which is modular in nature. Engineering practices assured with system safety standards to manage the failure, faulty, and unsafe operational conditions are very much necessary. System safety analyses involve the analysis of complex software architecture of the system, a major aspect in leading to fatal consequences in the behaviour of Safety-Critical Systems, and provide high reliability and dependability factors during their development. In this paper, we propose an architecture fault modeling and the safety analyses approach that will aid in identifying and eliminating the design flaws. The formal foundations of SAE Architecture Analysis & Design Language (AADL augmented with the Error Model Annex (EMV are discussed. The fault propagation, failure behaviour, and the composite behaviour of the design flaws/failures are considered for architecture safety analysis. The illustration of the proposed approach is validated by implementing the Speed Control Unit of Power-Boat Autopilot (PBA system. The Error Model Annex (EMV is guided with the pattern of consideration and inclusion of probable failure scenarios and propagation of fault conditions in the Speed Control Unit of Power-Boat Autopilot (PBA. This helps in validating the system architecture with the detection of the error event in the model and its impact in the operational environment. This also provides an insight of the certification impact that these exceptional conditions pose at various criticality levels and design assurance levels and its implications in verifying and validating the designs.

  20. Lateral restraint assembly in a nuclear reactor

    International Nuclear Information System (INIS)

    Brown, S.J.; Gorholt, W.

    1977-01-01

    A lateral restraint assembly is described for a reactor of, for example, the high temperature gas-cooled type which commonly includes a reactor core of relatively complex construction supported within a shell or vessel providing a shielded cavity for containing the reactor core. (U.K.)

  1. Assessing community child passenger safety efforts in three Northwest Tribes.

    Science.gov (United States)

    Smith, M L; Berger, L R

    2002-12-01

    To identify strengths and weaknesses in community based child passenger safety programs by developing a scoring instrument and conducting observations of child restraint use in three Native American communities. The three communities are autonomous Tribal reservations in the Pacific Northwest. Their per capita incomes and rates of unemployment are comparable. In each community, 100 children under 5 years old were observed for car seat use. A six item community assessment tool (100 points maximum) awarded points for such items as the type (primary or secondary) and enforcement of child restraint laws; availability of car seats from distribution programs; extent of educational programs; and access to data on vehicle injuries. For children from birth to 4 years, the car seat use rate ranged from 12%-21%. Rates for infants (71%-80%) far exceeded rates for 1-4 year old children (5%-14%). Community scores ranged from 0 to 31.5 points. There was no correlation between scores and observed car seat use. One reason was the total lack of enforcement of restraint laws. A community assessment tool can highlight weaknesses in child passenger efforts. Linking such a tool with an objective measure of impact can be applied to other injury problems, such as fire safety or domestic violence. The very process of creating and implementing a community assessment can enhance agency collaboration and publicize evidence based "best practices" for injury prevention. Further study is needed to address methodologic issues and to examine crash and medical data in relation to community child passenger safety scores.

  2. FOOD SAFETY CONTROL SYSTEM IN CHINA

    Institute of Scientific and Technical Information of China (English)

    Liu Wei-jun; Wei Yi-min; Han Jun; Luo Dan; Pan Jia-rong

    2007-01-01

    Most countries have expended much effort to develop food safety control systems to ensure safe food supplies within their borders. China, as one of the world's largest food producers and consumers,pays a lot of attention to food safety issues. In recent years, China has taken actions and implemented a series of plans in respect to food safety. Food safety control systems including regulatory, supervisory,and science and technology systems, have begun to be established in China. Using, as a base, an analysis of the current Chinese food safety control system as measured against international standards, this paper discusses the need for China to standardize its food safety control system. We then suggest some policies and measures to improve the Chinese food safety control system.

  3. Use of physical restraints and antipsychotic medications in nursing homes: a cross-national study.

    Science.gov (United States)

    Feng, Zhanlian; Hirdes, John P; Smith, Trevor F; Finne-Soveri, Harriet; Chi, Iris; Du Pasquier, Jean-Noel; Gilgen, Ruedi; Ikegami, Naoki; Mor, Vincent

    2009-10-01

    This study compares inter- and intra-country differences in the prevalence of physical restraints and antipsychotic medications in nursing homes, and examines aggregated resident conditions and organizational characteristics correlated with these treatments. Population-based, cross-sectional data were collected using a standardized Resident Assessment Instrument (RAI) from 14,504 long-term care facilities providing nursing home level services in five countries participating in the interRAI consortium, including Canada, Finland, Hong Kong (Special Administrative Region, China), Switzerland, and the United States. Facility-level prevalence rates of physical restraints and antipsychotic use were examined both between and within the study countries. The prevalence of physical restraint use varied more than five-fold across the study countries, from an average 6% in Switzerland, 9% in the US, 20% in Hong Kong, 28% in Finland, and over 31% in Canada. The prevalence of antipsychotic use ranged from 11% in Hong Kong, between 26-27% in Canada and the US, 34% in Switzerland, and nearly 38% in Finland. Within each country, substantial variations existed across facilities in both physical restraint and antipsychotic use rates. In all countries, neither facility case mix nor organizational characteristics were particularly predictive of the prevalence of either treatment. There exists large, unexplained variability in the prevalence of physical restraint and antipsychotic use in nursing home facilities both between and within countries. Since restraints and antipsychotics are associated with adverse outcomes, it is important to understand the idiosyncratic factors specific to each country that contribute to variation in use rates. Copyright (c) 2009 John Wiley & Sons, Ltd.

  4. NASA System Safety Handbook. Volume 1; System Safety Framework and Concepts for Implementation

    Science.gov (United States)

    Dezfuli, Homayoon; Benjamin, Allan; Everett, Christopher; Smith, Curtis; Stamatelatos, Michael; Youngblood, Robert

    2011-01-01

    System safety assessment is defined in NPR 8715.3C, NASA General Safety Program Requirements as a disciplined, systematic approach to the analysis of risks resulting from hazards that can affect humans, the environment, and mission assets. Achievement of the highest practicable degree of system safety is one of NASA's highest priorities. Traditionally, system safety assessment at NASA and elsewhere has focused on the application of a set of safety analysis tools to identify safety risks and formulate effective controls.1 Familiar tools used for this purpose include various forms of hazard analyses, failure modes and effects analyses, and probabilistic safety assessment (commonly also referred to as probabilistic risk assessment (PRA)). In the past, it has been assumed that to show that a system is safe, it is sufficient to provide assurance that the process for identifying the hazards has been as comprehensive as possible and that each identified hazard has one or more associated controls. The NASA Aerospace Safety Advisory Panel (ASAP) has made several statements in its annual reports supporting a more holistic approach. In 2006, it recommended that "... a comprehensive risk assessment, communication and acceptance process be implemented to ensure that overall launch risk is considered in an integrated and consistent manner." In 2009, it advocated for "... a process for using a risk-informed design approach to produce a design that is optimally and sufficiently safe." As a rationale for the latter advocacy, it stated that "... the ASAP applauds switching to a performance-based approach because it emphasizes early risk identification to guide designs, thus enabling creative design approaches that might be more efficient, safer, or both." For purposes of this preface, it is worth mentioning three areas where the handbook emphasizes a more holistic type of thinking. First, the handbook takes the position that it is important to not just focus on risk on an individual

  5. Restraint Stress Impairs Glucose Homeostasis Through Altered ...

    African Journals Online (AJOL)

    olayemitoyin

    serum level of adiponectin was significantly (p< 0.05) lower compared with ... were significantly (p< 0.05) decreased in the skeletal muscle of restraint stress exposed rats. ... controlled conditions for the light/dark cycle, ..... increase the production of catecholamines. ... specific protein that has been suggested to play a role.

  6. Keeping our children safe in motor vehicles: knowledge, attitudes and practice among parents in Kuwait regarding child car safety.

    Science.gov (United States)

    Raman, Sudha R; Landry, Michel D; Ottensmeyer, C Andrea; Jacob, Susan; Hamdan, Elham; Bouhaimed, Manal

    2013-01-01

    Child safety restraints can reduce risk of death and decrease injury severity from road traffic crashes; however, knowledge about restraints and their use in Kuwait is limited. A cross-sectional, self-administered survey about child car safety was used among a convenience sample of parents of children aged 18 years or younger at five Kuwaiti university campuses. Of 552 respondents, over 44% have seated a child in the front seat and 41.5% have seated a child in their lap while driving. Few parents are aware of and fewer report using the appropriate child restraint; e.g., 36% of parents of infants recognised an infant seat and 26% reported using one. Over 70% reported wearing seat belts either "all of the time" (33%) or "most of the time" (41%). This new information about parents' knowledge and practice regarding child car seat use in Kuwait can inform interventions to prevent child occupant injury and death.

  7. Effect of PCMI restraint on bubble size distribution in the rim structure of UO2 fuel

    International Nuclear Information System (INIS)

    Oh, Je-Yong; Koo, Yang-Hyun; Cheon, Jin-Sik; Lee, Byung-Ho; Sohn, Dong-Seong

    2005-01-01

    Generally, the bubble size in the rim structure of UO 2 is not dependent on the fuel burnup and the bubble pressure is higher than that in the equilibrium condition. However it was also observed that if the fuel pellet is not restrained, the size of the bubbles in the rim structure could be larger than that in the restraint condition. Although the wide variety of rim bubble sizes and porosities possibly result from an external restrain effect, the quantitative method to analyze the effect of PCMI restraint on bubble distribution in the rim is not available at the moment. In this paper, a method is developed which can be used to analyze the effect of PCMI restraint on the bubble distribution in the rim structure of UO 2 fuel based on the data in the literatures. The total number of Xe atoms in the rim bubbles per unit rim volume could be derived by a summation of the number of Xe atoms of each rim bubble in a unit rim volume. The number of Xe atoms of each rim bubble could be calculated by the Van der Waals equation of state and the pressure expressed by p=σ+C/r, where C is an unknown constant to be determined as a function of the temperature and the burnup. On the other hand, the total number of Xe atoms in the rim bubbles per unit rim volume can also be calculated by Xe depression data. If the fuel pellet is not restrained, the uniform hydrostatic stress, σ is zero. Hence if the data of the fuel disk without a restraint is used, a constant C can be obtained at 823K and a local burnup of 90 GWd/t. Although the local burnup of PCMI restraint case is slightly different from that without PCMI restraint, the value derived above is used for the analysis of PCMI restraint case. The calculated bubble distribution with PCMI restraint was similar to the measured one. Because the effect of PCMI restraint on bubble size increased with the bubble size, the development of a large bubble was suppressed. Hence, the PCMI restraint caused a typical bubble size in the rim and

  8. Correct use of safety belts and child restraint devices in cars among children in Goiânia.

    Science.gov (United States)

    de Sousa, Roberto Medeiros; Felisbino Júnior, Pedro; Braga, Felipe de Moura; da Costa Neto, Sílvio Dias; Belo, Felipe Marques; Reginaldo, Sandro da Silva; de Moraes, Frederico Barra

    2014-01-01

    to conduct an observational study, by means of campaigns, regarding the use of child restraint devices in cars in Goiânia. this was a cross-sectional study using a convenience sample built up as cases arose. The data were gathered into an Excel spreadsheet and were analyzed descriptively and statistically (SPSS 16.0), using chi-square and taking p vehicles were transporting children on the rear seats, and this was being done correctly in 214 vehicles, i.e. 46.72%. In 2006, of the 410 vehicles analyzed, only 90 of them (21.95%) were transporting children correctly (p vehicles, with an improvement of 25% (p media, and because of legal obligations.

  9. Greater hunger and less restraint predict weight loss success with phentermine treatment.

    Science.gov (United States)

    Thomas, Elizabeth A; Mcnair, Bryan; Bechtell, Jamie L; Ferland, Annie; Cornier, Marc-Andre; Eckel, Robert H

    2016-01-01

    Phentermine is thought to cause weight loss through a reduction in hunger. It was hypothesized that higher hunger ratings would predict greater weight loss with phentermine. This is an observational pilot study in which all subjects were treated with phentermine for 8 weeks and appetite and eating behaviors were measured at baseline and week 8. Outcomes were compared in subjects with ≥5% vs. hunger (P = 0.017), desire to eat (P =0.003), and prospective food consumption (0.006) and lower baseline cognitive restraint (P = 0.01). In addition, higher baseline home prospective food consumption (P = 0.002) and lower baseline cognitive restraint (P hunger and less restraint are more likely to achieve significant weight loss with phentermine. This information can be used clinically to determine who might benefit most from phentermine treatment. © 2015 The Obesity Society.

  10. Examination of ethical dilemmas experienced by adult intensive care unit nurses in physical restraint practices.

    Science.gov (United States)

    Yönt, Gülendam Hakverdioğlu; Korhan, Esra Akin; Dizer, Berna; Gümüş, Fatma; Koyuncu, Rukiye

    2014-01-01

    Nurses are more likely to face the dilemma of whether to resort to physical restraints or not and have a hard time making that decision. This is a descriptive study. A total of 55 nurses participated in the research. For data collection, a question form developed by researchers to determine perceptions of ethical dilemmas by nurses in the application of physical restraint was used. A descriptive analysis was made by calculating the mean, standard deviation, and maximum and minimum values. The nurses expressed (36.4%) having difficulty in deciding to use physical restraint. Nurses reported that they experience ethical dilemmas mainly in relation to the ethic principles of nonmaleficence, beneficence, and convenience. We have concluded that majority of nurses working in critical care units apply physical restraint to patients, although they are facing ethical dilemmas concerning harm and benefit principles during the application.

  11. A pilot study of "post-seclusion and/or restraint review" intervention with patients and staff in a mental health setting.

    Science.gov (United States)

    Goulet, Marie-Hélène; Larue, Caroline; Lemieux, Ashley J

    2018-04-01

    To develop and evaluate a "post-seclusion and/or restraint review" (PSRR) intervention implemented in an acute psychiatric care unit. Twelve staff members and three patients were enrolled in a participatory case study. To evaluate PSRR intervention, qualitative analysis was carried out. Seclusion and restraint use 6 months before and after the PSRR implementation was compared. Nurses reported that they were able to explore the patient's feelings during the PSRR intervention with patients, which led to restoration of the therapeutic relationship. PSRR with the treatment team was perceived as a learning opportunity, which allowed to improve the therapeutic intervention. Both the use of seclusion and the time spent in seclusion were significantly reduced 6 months after the implementation of PSRR intervention. Our results suggest the efficacy of PSRR in overcoming the discomfort perceived by both staff and patient and, in the meantime, in reducing the need for coercive procedures. Systematic PSRR could permit to improve the quality of care and the safety of aggressiveness management. © 2017 Wiley Periodicals, Inc.

  12. Instrumentation and control systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    This Safety Guide was prepared under the IAEA programme for establishing safety standards for nuclear power plants. It supplements Safety Standards Series No. NS-R-1: Safety of Nuclear Power Plants: Design (the Requirements for Design), which establishes the design requirements for ensuring the safety of nuclear power plants. This Safety Guide describes how the requirements should be met for instrumentation and control (I and C) systems important to safety. This publication is a revision and combination of two previous Safety Guides: Safety Series Nos 50-SG-D3 and 50-SG-D8, which are superseded by this new Safety Guide. The revision takes account of developments in I and C systems important to safety since the earlier Safety Guides were published in 1980 and 1984, respectively. The objective of this Safety Guide is to provide guidance on the design of I and C systems important to safety in nuclear power plants, including all I and C components, from the sensors allocated to the mechanical systems to the actuated equipment, operator interfaces and auxiliary equipment. This Safety Guide deals mainly with design requirements for those I and C systems that are important to safety. It expands on paragraphs of Ref in the area of I and C systems important to safety. This publication is intended for use primarily by designers of nuclear power plants and also by owners and/or operators and regulators of nuclear power plants. This Safety Guide provides general guidance on I and C systems important to safety which is broadly applicable to many nuclear power plants. More detailed requirements and limitations for safe operation specific to a particular plant type should be established as part of the design process. The present guidance is focused on the design principles for systems important to safety that warrant particular attention, and should be applied to both the design of new I and C systems and the modernization of existing systems. Guidance is provided on how design

  13. Functionality of road safety devices – identification and analysis of factors

    Directory of Open Access Journals (Sweden)

    Jeliński Łukasz

    2017-01-01

    Full Text Available Road safety devices are designed to protect road users from the risk of injury or death. The principal type of restraint is the safety barrier. Deployed on sites with the highest risk of run-off-road accidents, safety barriers are mostly found on bridges, flyovers, central reservations, and on road edges which have fixed obstacles next to them. If properly designed and installed, safety barriers just as other road safety devices, should meet a number of functional features. This report analyses factors which may deteriorate functionality, ways to prevent this from happening and the thresholds for loss of road safety device functionality.

  14. Nursing staff members' intentions to use physical restraints with older people: testing the theory of reasoned action.

    Science.gov (United States)

    Werner, P; Mendelsson, G

    2001-09-01

    To examine nursing staff members' attitudes, subjective norms, moral obligations and intentions to use physical restraints, using the Theory of Reasoned Action (TRA). During the last two decades an extensive body of research has examined nurses' attitudes as one of the main factors affecting the decision to use or not to use physical restraints with older persons. However, no studies have examined empirically the antecedents to nurses' intentions to use physical restraints within a theoretically based framework. A correlational design was used with 303 nursing staff members from an 800-bed elder care hospital in central Israel. Participants completed a questionnaire including questions based on the TRA as well as socio-demographic and professional characteristics. Regression analyses found attitudes, subjective norms and moral considerations to be significantly associated to intention to use physical restraints with older people. The TRA explained 48% of the variance in nurses' intentions. The TRA proved to be a useful framework for examining nurses' intentions to use physical restraints. Nurses' attitudes, beliefs and expectations of significant others should be examined before implementing educational programmes regarding the use of physical restraints.

  15. How could intelligent safety transport systems enhance safety ?

    NARCIS (Netherlands)

    Wiethoff, M. Heijer, T. & Bekiaris, E.

    2017-01-01

    In Europe, many deaths and injured each years are the cost of today's road traffic. Therefore, it is wise to look for possible solutions for enhancing traffic safety. Some Advanced Driver Assistance Systems (ADAS) are expected to increase safety, but they may also evoke new safety hazards. Only

  16. Contributions of mindful eating, intuitive eating, and restraint to BMI, disordered eating, and meal consumption in college students.

    Science.gov (United States)

    Anderson, Lisa M; Reilly, Erin E; Schaumberg, Katherine; Dmochowski, Sasha; Anderson, Drew A

    2016-03-01

    Mindful eating and intuitive eating are promoted as means to circumvent potentially maladaptive dietary restraint while maintaining a healthy weight. Although theoretically related, no studies have examined the correlations between intuitive eating, mindful eating, and restraint in the same sample. This study sought to examine these constructs and their correlations with body mass index (BMI), eating-disordered behaviors, and meal consumption in a college sample. Participants (N = 125) completed a laboratory taste-test meal and measures of each eating-related construct using the EDDS, IES, MEQ, and TFEQ-Restraint Subscale. Mindful eating, intuitive eating, and restraint were not strongly correlated. Hierarchical multiple regression analyses indicated that restraint and intuitive eating accounted for significant variance in disordered eating and BMI. Elevated restraint was associated with increased BMI and disordered eating; elevated intuitive eating was associated with decreased BMI and disordered eating. Mindful eating did not correlate with any outcome variables. Follow-up analyses suggested that specific intuitive eating subscales accounted for unique variance in the relation between intuitive eating and disordered eating. Intuitive eating was the only construct that was significantly associated with meal consumption. Intuitive eating and restraint appear to be only weakly correlated, and each is differentially associated with meal consumption. Mindful eating does not appear to relate to outcome variables.

  17. Safety Review related to Commercial Grade Digital Equipment in Safety System

    International Nuclear Information System (INIS)

    Yu, Yeongjin; Park, Hyunshin; Yu, Yeongjin; Lee, Jaeheung

    2013-01-01

    The upgrades or replacement of I and C systems on safety system typically involve digital equipment developed in accordance with non-nuclear standards. However, the use of commercial grade digital equipment could include the vulnerability for software common-mode failure, electromagnetic interference and unanticipated problems. Although guidelines and standards for dedication methods of commercial grade digital equipment are provided, there are some difficulties to apply the methods to commercial grade digital equipment for safety system. This paper focuses on regulatory guidelines and relevant documents for commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. This paper focuses on KINS regulatory guides and relevant documents for dedication of commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. Dedication including critical characteristics is required to use the commercial grade digital equipment on safety system in accordance with KEPIC ENB 6370 and EPRI TR-106439. The dedication process should be controlled in a configuration management process. Appropriate methods, criteria and evaluation result should be provided to verify acceptability of the commercial digital equipment used for safety function

  18. Safety parameter display system: an operator support system for enhancement of safety in Indian PHWRs

    International Nuclear Information System (INIS)

    Subramaniam, K.; Biswas, T.

    1994-01-01

    Ensuring operational safety in nuclear power plants is important as operator errors are observed to contribute significantly to the occurrence of accidents. Computerized operator support systems, which process and structure information, can help operators during both normal and transient conditions, and thereby enhance safety and aid effective response to emergency conditions. An important operator aid being developed and described in this paper, is the safety parameter display system (SPDS). The SPDS is an event-independent, symptom-based operator aid for safety monitoring. Knowledge-based systems can provide operators with an improved quality of information. An information processing model of a knowledge based operator support system (KBOSS) developed for emergency conditions using an expert system shell is also presented. The paper concludes with a discussion of the design issues involved in the use of a knowledge based systems for real time safety monitoring and fault diagnosis. (author). 8 refs., 4 figs., 1 tab

  19. Construct Validation of the Portuguese Version of the Restraint Scale

    Directory of Open Access Journals (Sweden)

    João Carvalho

    2016-08-01

    Full Text Available AimThe main purpose of this study was to adapt the Restraint Scale (RS to Portuguese and examine its psychometric properties, specifically its construct validity.MethodIn this study, 238 normal-weight adults (82% women; Mean age = 36.6, SD = 15.0 participated in an online survey containing measures of Restraint Scale, Three Factor Eating Questionnaire, Dutch Eating Behaviour Questionnaire, and Body Dissatisfaction and Drive for Thinness scales.ResultsExploratory factor analyses corroborated the two-factors structure found in previous studies, in particular when three items without clear factorial assignment and low correlation were excluded. A final two-factors version of the RS containing seven items presented a very good fit to the measurement model and good internal consistency. Confirmatory factor analysis of the 7-items RS in relation to a three-factor model of overeating, dieting and body dissatisfaction measures revealed that the RS was the only restraint measure loading in all three factors.ConclusionThis suggests that the 7-items Portuguese version of the RS has good psychometric properties and unique features that lend it appropriate to identify and study unsuccessful chronic dieters.

  20. Effects of chronic restraint stress on body weight, food intake, and hypothalamic gene expressions in mice.

    Science.gov (United States)

    Jeong, Joo Yeon; Lee, Dong Hoon; Kang, Sang Soo

    2013-12-01

    Stress affects body weight and food intake, but the underlying mechanisms are not well understood. We evaluated the changes in body weight and food intake of ICR male mice subjected to daily 2 hours restraint stress for 15 days. Hypothalamic gene expression profiling was analyzed by cDNA microarray. Daily body weight and food intake measurements revealed that both parameters decreased rapidly after initiating daily restraint stress. Body weights of stressed mice then remained significantly lower than the control body weights, even though food intake slowly recovered to 90% of the control intake at the end of the experiment. cDNA microarray analysis revealed that chronic restraint stress affects the expression of hypothalamic genes possibly related to body weight control. Since decreases of daily food intake and body weight were remarkable in days 1 to 4 of restraint, we examined the expression of food intake-related genes in the hypothalamus. During these periods, the expressions of ghrelin and pro-opiomelanocortin mRNA were significantly changed in mice undergoing restraint stress. Moreover, daily serum corticosterone levels gradually increased, while leptin levels significantly decreased. The present study demonstrates that restraint stress affects body weight and food intake by initially modifying canonical food intake-related genes and then later modifying other genes involved in energy metabolism. These genetic changes appear to be mediated, at least in part, by corticosterone.

  1. Comprehensive Lifecycle for Assuring System Safety

    Science.gov (United States)

    Knight, John C.; Rowanhill, Jonathan C.

    2017-01-01

    CLASS is a novel approach to the enhancement of system safety in which the system safety case becomes the focus of safety engineering throughout the system lifecycle. CLASS also expands the role of the safety case across all phases of the system's lifetime, from concept formation to decommissioning. As CLASS has been developed, the concept has been generalized to a more comprehensive notion of assurance becoming the driving goal, where safety is an important special case. This report summarizes major aspects of CLASS and contains a bibliography of papers that provide additional details.

  2. Belt restraint reduction in nursing homes: design of a quasi-experimental study

    Directory of Open Access Journals (Sweden)

    van Rossum Erik

    2010-02-01

    Full Text Available Abstract Background The use of physical restraints still is common practice in the nursing home care. Since physical restraints have been shown to be an ineffective and sometimes even hazardous measure, interventions are needed to reduce their usage. Several attempts have been made to reduce the use of physical restraints. Most studies used educational approaches and introduced a nurse specialist as a consultant. However, the success rate of these interventions has been inconsistent. We developed a new multi-component intervention (EXBELT comprising an educational intervention for nursing home staff in combination with a policy change (belt use is prohibited by the nursing home management, availability of a nurse specialist and nursing home manager as consultants, and availability of alternative interventions. The first aim of this study is to further develop and test the effectiveness of EXBELT on belt restraint reduction in Dutch psychogeriatric nursing homes. However, the reduction of belts should not result in an increase of other restrictive restraints (such as a chair with locked tray table or psychoactive drug use. The overall aim is an effective and feasible intervention that can be employed on a large scale in Dutch nursing homes. Methods and design Effects of EXBELT will be studied in a quasi-experimental longitudinal study design. Alongside the effect evaluation, a process evaluation will be carried out in order to further develop EXBELT. Data regarding age, gender, use of physical restraints, the number of falls and fall related injuries, psychoactive drug use, and the use of alternative interventions will be collected at baseline and after four and eight months of follow-up. Data regarding the process evaluation will be gathered in a period of eight months between baseline and the last measurement. Furthermore, changing attitudes will become an important addition to the educational part of EXBELT. Discussion A quasi

  3. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  4. Effects of off-centered crack and restraint of induced bending due to pressure on the crack-opening-area analysis of pipes

    International Nuclear Information System (INIS)

    Rahman, S.; Ghadiali, N.; Wilkowski, G.; Bonora, N.

    1995-01-01

    Estimation of leak rate is an important element in developing leak-before-break (LBB) methodology for piping integrity and safety analysis of nuclear power plants. Here, current models for the crack-opening-area analysis of pipes with circumferential through-wall cracks are based on various idealizations or assumption which are often necessary to simplify the mathematical formulation and numerical calculation. This paper focuses on the validity of two such assumptions involving off-centered cracks and restraint of induced bending due to pressure and quantifies their effects on the crack-opening analysis of pipes. Both finite element and/or simple estimation methods were employed to compute the center-crack-opening displacement and crack-opening shape for a through-wall-cracked pipe considering off-centered cracks and restrain of induced bending due to pressure. The results of analyses show that for both cases the crack-opening area can be reduced significantly. For pipes with off-centered cracks, the crack-opening area can be evaluated from analyses of symmetrically centered cracks and assuming elliptical profile. For pipes with complete restraint of induced bending due to pressure, the reduction of crack-opening area depends on the crack size. When the crack size is small, the restraint effects can be ignored. However, when the crack size is larger, the restrained crack-opening can be significantly smaller than the unrestrained crack-opening depending on the length of pipe involved, and hence, may be important for the crack-opening-area and leak-rate analyses

  5. Evaluation of the five-year Bloomberg Philanthropies Global Road Safety Program in the Russian Federation.

    Science.gov (United States)

    Gupta, S; Paichadze, N; Gritsenko, E; Klyavin, V; Yurasova, E; Hyder, A A

    2017-03-01

    Road traffic injuries are a leading cause of morbidity and mortality in the world. In Russia, a road safety program was implemented in Lipetskaya and Ivanovskaya oblasts (regions) as part of a 10-country effort funded by Bloomberg Philanthropies. The program was focused on increasing seat belt and child restraint use and reducing speeding. The primary goals of this monitoring and evaluation study are to assess trends in seat belt use, child restraint use, and speed compliance in the two oblasts over the 5 years and to explore the overall impact of the program on road traffic injury and death rates. Primary data via roadside observations and interviews, and secondary data from official government sources were collected and analyzed for this study. Our results indicate significant improvements in seat belt wearing and child seat use rates and in prevalence of speeding in both intervention oblasts. The observations were consistent with the results from the roadside interviews. In Lipetskaya, restraint use by all occupants increased from 52.4% (baseline, October 2010) to 77.4% (final round, October 2014) and child restraint use increased from 20.9% to 54.1% during the same period. In Ivanovskaya, restraint use by all occupants increased from 48% (baseline, April 2012) to 88.7% (final round, October 2014) and child restraint use increased from 20.6% to 89.4% during the same period. In Lipetskaya, the overall prevalence of speeding (vehicles driving above speed limit) declined from 47.0% (baseline, July 2011) to 30.4% (final round, October 2014) and a similar pattern was observed in Ivanovskaya where the prevalence of speeding decreased from 54.6% (baseline, March 2012) to 46.6% (final round, October 2014). Through 2010-2014, the road traffic crash and injury rates per 100,000 population decreased in Lipetskaya oblast (191.5 and 246.9 in 2010 and 170.4 and 208.6 in 2014, respectively) and slightly increased in Ivanovskaya oblast (184.4 and 236.0 in 2010 and 186.7 and 243

  6. Growth and Predictors of Growth Restraint in Moderately Preterm Children Aged 0 to 4 Years

    NARCIS (Netherlands)

    Bocca-Tjeertes, I.F.; Kerstjens, J.M.; Reijneveld, S.A.; de Winter, A.F.; Bos, A.F.

    2011-01-01

    OBJECTIVE: To describe growth in moderately preterm-born children, determine the prevalence of growth restraint at the age of 4, and identify predictors of growth restraint. We hypothesized that growth in moderately preterm-born children differs from growth in term-born children and that growth

  7. Seclusion and restraint in psychiatry: patients' experiences and practical suggestions on how to improve practices and use alternatives.

    Science.gov (United States)

    Kontio, Raija; Joffe, Grigori; Putkonen, Hanna; Kuosmanen, Lauri; Hane, Kimmo; Holi, Matti; Välimäki, Maritta

    2012-01-01

    This study explored psychiatric inpatients' experiences of, and their suggestions for, improvement of seclusion/restraint, and alternatives to their use in Finland. The data were collected by focused interviews (n= 30) and were analyzed with inductive content analysis. Patients' perspectives received insufficient attention during seclusion/restraint processes. Improvements (e.g., humane treatment) and alternatives (e.g., empathetic patient-staff interaction) to seclusion/restraint, as suggested by the patients, focused on essential parts of nursing practice but have not been largely adopted. Patients' basic needs have to be met, and patient-staff interaction has to also continue during seclusion/restraint. Providing patients with meaningful activities, planning beforehand, documenting the patients' wishes, and making patient-staff agreements reduce the need for restrictions and offer alternatives for seclusion/restraint. Service users must be involved in all practical development. © 2011 Wiley Periodicals, Inc.

  8. Repeated Neck Restraint Stress Bidirectionally Modulates Excitatory Transmission in the Dentate Gyrus and Performance in a Hippocampus-dependent Memory Task.

    Science.gov (United States)

    Spyrka, Jadwiga; Hess, Grzegorz

    2018-05-21

    The consequences of stress depend on characteristics of the stressor, including the duration of exposure, severity, and predictability. Exposure of mice to repeated neck restraint has been shown to bidirectionally modulate the potential for long-term potentiation (LTP) in the dentate gyrus (DG) in a manner dependent on the number of restraint repetitions, but the influence of repeated brief neck restraint on electrophysiology of single DG neurons has not yet been investigated. Here, we aimed at finding the effects of 1, 3, 7, 14, or 21 daily neck restraint sessions lasting 10 min on electrophysiological characteristics of DG granule cells as well as excitatory and inhibitory synaptic inputs to these neurons. While the excitability of DG granule cells and inhibitory synaptic transmission were unchanged, neck restraint decreased the frequency of spontaneous excitatory currents after three repetitions but enhanced it after 14 and 21 repetitions. The consequences of repeated neck restraint on hippocampus-dependent memory were investigated using the object location test (OLT). Neck restraint stress impaired cognitive performance in the OLT after three repetitions but improved it after 14 and 21 repetitions. Mice subjected to three neck restraint sessions displayed an increase in the measures of depressive and anxiety-like behaviors, however, prolongation of the exposure to neck restraint resulted in a gradual decline in the intensity of these measures. These data indicate that stress imposed by an increasing number of repeated neck restraint episodes bidirectionally modulates both excitatory synaptic transmission in the DG and cognitive performance in the object location memory task. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.

  9. Knowledge, attitudes, and behaviors related to child safety restraint in citizens of Shenzhen Municipality, China, and the associations between these factors.

    Science.gov (United States)

    Liu, Shengyuan; Zhou, Haibin; Ma, Jianping; Wang, Changyi; Chen, Zhongwei; Chen, Sihan; Yang, Yingzhou; Liu, Xiaoli; Peng, Ji; Duan, Leilei; Deng, Xiao

    2018-01-02

    A child safety restraint (CSR) is an effective measure to reduce the risk of child injury from traffic collisions. This study aims to explore knowledge, attitudes, and behaviors regarding CSRs in a Chinese population. A cross-sectional survey regarding CSR use was conducted from April to May 2014 in Shenzhen municipality. Respondents were parents who had at least one child 0 to 6 years of age and owned a car. These parents provided a self-report of demographic characteristics as well as information about their knowledge, attitudes, and behaviors toward CSR use. Most respondents had a fair level of knowledge about CSRs, with higher mean knowledge scores demonstrated among the respondents who were male, had an advanced degree, had a higher income, owned an expensive car, had an older child, drove frequently with children, and routinely drove greater distances with children. In addition, most respondents had a more positive attitude toward CSR use, with a higher mean attitude score among those who had an advanced degree, owned an expensive car, drove frequently with children, and routinely drove greater distances with children. However, some myths regarding CSR use also existed (e.g., parents can effectively protect their children in a car collision by holding them, they are not required to purchase the CSR for child safety if there is no mandatory provision by law, among others). Among 3,768 respondents who had at least one child and a car, 27.8% (1,047) had a CSR and 22.9% (864) used the CSR. A logistic regression model showed the likelihood of CSR ownership to be higher if respondents drove frequently or greater distances and was dependent on both the education level of the respondents and the age of the children. The frequency of CSR use increased as the age of children decreased (P = .0274). Respondents who owned a CSR and those who frequently used CSRs had higher mean knowledge and mean attitude scores. This observational study found that although the majority

  10. Applying sensory modulation to mental health inpatient care to reduce seclusion and restraint: a case control study.

    Science.gov (United States)

    Andersen, Charlotte; Kolmos, Anne; Andersen, Kjeld; Sippel, Volkmar; Stenager, Elsebeth

    2017-10-01

    Clinical training in managing conflicts and preventing violence seldom contains sensory modulation (SM) as a method to de-escalate and prevent restraint and seclusion. Sensory-based interventions promote adaptive regulation of arousal and emotion. SM is a complementary approach that is associated with reduced rates of seclusion and restraint in mental healthcare, but there is need for more research in this area. Using SM to reduce restraint and seclusion in inpatient mental health care. The study included two similar psychiatric units where one unit implemented SM and one unit served as the control group. In the very beginning of the study, a staff-training program in the use of SM including assessment tools and intervention strategies was established. Data on restraint and forced medicine were sampled post the course of the year of implementation and compared with the control group. The use of belts decreased with 38% compared to the control group. The use of forced medication decreased with 46% compared to the control group. Altogether the use of physical restraint and forced medication decreased significantly with 42% (p mental healthcare facilities has a significant effect on the reduction of restraint and seclusion. As a part of the implementation, staff training and education in SM are crucial.

  11. How Farm Animals React and Perceive Stressful Situations Such As Handling, Restraint, and Transport

    Directory of Open Access Journals (Sweden)

    Temple Grandin

    2015-12-01

    Full Text Available An animal that has been carefully acclimated to handling may willingly re-enter a restrainer. Another animal may have an intense agitated behavioral reaction or refuse to re-enter the handling facility. Physiological measures of stress such as cortisol may be very low in the animal that re-enters willingly and higher in animals that actively resist restraint. Carefully acclimating young animals to handling and restraint can help improve both productivity and welfare by reducing fear stress. Some of the topics covered in this review are: How an animal perceives handling and restraint, the detrimental effects of a sudden novel event, descriptions of temperament and aversion tests and the importance of good stockmanship.

  12. Modification of hippocampal markers of synaptic plasticity by memantine in animal models of acute and repeated restraint stress: implications for memory and behavior.

    Science.gov (United States)

    Amin, Shaimaa Nasr; El-Aidi, Ahmed Amro; Ali, Mohamed Mostafa; Attia, Yasser Mahmoud; Rashed, Laila Ahmed

    2015-06-01

    Stress is any condition that impairs the balance of the organism physiologically or psychologically. The response to stress involves several neurohormonal consequences. Glutamate is the primary excitatory neurotransmitter in the central nervous system, and its release is increased by stress that predisposes to excitotoxicity in the brain. Memantine is an uncompetitive N-methyl D-aspartate glutamatergic receptors antagonist and has shown beneficial effect on cognitive function especially in Alzheimer's disease. The aim of the work was to investigate memantine effect on memory and behavior in animal models of acute and repeated restraint stress with the evaluation of serum markers of stress and the expression of hippocampal markers of synaptic plasticity. Forty-two male rats were divided into seven groups (six rats/group): control, acute restraint stress, acute restraint stress with Memantine, repeated restraint stress, repeated restraint stress with Memantine and Memantine groups (two subgroups as positive control). Spatial working memory and behavior were assessed by performance in Y-maze. We evaluated serum cortisol, tumor necrotic factor, interleukin-6 and hippocampal expression of brain-derived neurotrophic factor, synaptophysin and calcium-/calmodulin-dependent protein kinase II. Our results revealed that Memantine improved spatial working memory in repeated stress, decreased serum level of stress markers and modified the hippocampal synaptic plasticity markers in both patterns of stress exposure; in ARS, Memantine upregulated the expression of synaptophysin and brain-derived neurotrophic factor and downregulated the expression of calcium-/calmodulin-dependent protein kinase II, and in repeated restraint stress, it upregulated the expression of synaptophysin and downregulated calcium-/calmodulin-dependent protein kinase II expression.

  13. A Methodological Framework for Software Safety in Safety Critical Computer Systems

    OpenAIRE

    P. V. Srinivas Acharyulu; P. Seetharamaiah

    2012-01-01

    Software safety must deal with the principles of safety management, safety engineering and software engineering for developing safety-critical computer systems, with the target of making the system safe, risk-free and fail-safe in addition to provide a clarified differentaition for assessing and evaluating the risk, with the principles of software risk management. Problem statement: Prevailing software quality models, standards were not subsisting in adequately addressing the software safety ...

  14. Study of system safety evaluation on LTO of national project. NISA safety research project on system safety of nuclear power plants

    International Nuclear Information System (INIS)

    Takizawa, Masayuki; Sekimura, Naoto; Miyano, Hiroshi; Aoyama, Katsunobu

    2012-01-01

    Japanese safety regulatory body, that is, Nuclear and Industrial Safety Agency (NISA) started a 5-year national safety research project as 'the first stage' from 2006 FY to 2010 FY whose objective is 'Improve the technical information basis in order to utilize knowledge as well as information related to ageing management and maintenance of NPPs. Fukushima disaster happened in March 2011, and the priority of research needs for ageing management dramatically changed in Japan. The second-stage national project started in October 2011 with the concept of 'system safety' of NNPs where not only ageing management on degradation phenomena of important components but also safety management on total plant systems are paid attention to. The second-stage project is so called 'Japanese Ageing Management Program for System Safety (JAMPSS)'. (author)

  15. High-Mobility Multipurpose Wheeled Vehicle Rollover Accidents and Injuries to U.S. Army Soldiers by Reported Occupant Restraint Use, 1992-2013.

    Science.gov (United States)

    Lo, Michael C; Giffin, Robert P; Pakulski, Kraig A; Davis, W Sumner; Bernstein, Stephen A; Wise, Daniel V

    2017-05-01

    1,395 occupants (828 nonfatally injured, 151 fatally injured, and 416 noninjured). Thirty-five percent of more severe (class A and B) accidents involved the M1114 up-armored variant, whereas 32% of less severe (class C and D) accidents involved the M998 nonarmored variant. Unrestrained occupants were 20% more likely to be nonfatally injured and 5.6 times more likely to be fatally injured than were restrained occupants. Among unrestrained occupants, restraint use could have potentially saved 82% of lives lost. Among all occupants involved in a HMMWV rollover, an estimated 56% of fatalities could have been prevented by restraint use. Unrestrained drivers and vehicle commanders had greater than expected torso injuries, while restrained vehicle commanders and passengers had greater than expected upper extremity injuries. Unrestrained drivers had greater than expected fractures, whereas restrained drivers and vehicle commanders had greater than expected sprains/strains. While reporting bias may exist, nevertheless these results show that occupant restraint use confers substantial life-saving protection to HMMWV occupants in rollover accidents. Therefore, commanders, safety officers, and peers should continue to promote and enforce restraint use consistently during all Army ground operations and training involving HMMWVs. Doing so will save Soldiers' lives in rollover accidents during the remaining years of the HMMWV program. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  16. Driver kinematic and muscle responses in braking events with standard and reversible pre-tensioned restraints: validation data for human models.

    Science.gov (United States)

    Osth, Jonas; Olafsdóttir, Jóna Marín; Davidsson, Johan; Brolin, Karin

    2013-11-01

    The objectives of this study are to generate validation data for human models intended for simulation of occupant kinematics in a pre-crash phase, and to evaluate the effect of an integrated safety system on driver kinematics and muscle responses. Eleven male and nine female volunteers, driving a passenger car on ordinary roads, performed maximum voluntary braking; they were also subjected to autonomous braking events with both standard and reversible pre-tensioned restraints. Kinematic data was acquired through film analysis, and surface electromyography (EMG) was recorded bilaterally for muscles in the neck, the upper extremities, and lumbar region. Maximum voluntary contractions (MVCs) were carried out in a driving posture for normalization of the EMG. Seat belt positions, interaction forces, and seat indentions were measured. During normal driving, all muscle activity was below 5% of MVC for females and 9% for males. The range of activity during steady state braking for males and females was 13-44% in the cervical and lumbar extensors, while antagonistic muscles showed a co-contraction of 2.3-19%. Seat belt pre-tension affects both the kinematic and muscle responses of drivers. In autonomous braking with standard restraints, muscle activation occurred in response to the inertial load. With pre-tensioned seat belts, EMG onset occurred earlier; between 71 ms and 176 ms after belt pre-tension. The EMG onset times decreased with repeated trials and were shorter for females than for males. With the results from this study, further improvement and validation of human models that incorporate active musculature will be made possible.

  17. Preliminary safety evaluation for CSR1000 with passive safety system

    International Nuclear Information System (INIS)

    Wu, Pan; Gou, Junli; Shan, Jianqiang; Zhang, Bo; Li, Xiang

    2014-01-01

    Highlights: • The basic information of a Chinese SCWR concept CSR1000 is introduced. • An innovative passive safety system is proposed for CSR1000. • 6 Transients and 3 accidents are analysed with system code SCTRAN. • The passive safety systems greatly mitigate the consequences of these incidents. • The inherent safety of CSR1000 is enhanced. - Abstract: This paper describes the preliminary safety analysis of the Chinese Supercritical water cooled Reactor (CSR1000), which is proposed by Nuclear Power Institute of China (NPIC). The two-pass core design applied to CSR1000 decreases the fuel cladding temperature and flattens the power distribution of the core at normal operation condition. Each fuel assembly is made up of four sub-assemblies with downward-flow water rods, which is favorable to the core cooling during abnormal conditions due to the large water inventory of the water rods. Additionally, a passive safety system is proposed for CSR1000 to increase the safety reliability at abnormal conditions. In this paper, accidents of “pump seizure”, “loss of coolant flow accidents (LOFA)”, “core depressurization”, as well as some typical transients are analysed with code SCTRAN, which is a one-dimensional safety analysis code for SCWRs. The results indicate that the maximum cladding surface temperatures (MCST), which is the most important safety criterion, of the both passes in the mentioned incidents are all below the safety criterion by a large margin. The sensitivity analyses of the delay time of RCPs trip in “loss of offsite power” and the delay time of RMT actuation in “loss of coolant flowrate” were also included in this paper. The analyses have shown that the core design of CSR1000 is feasible and the proposed passive safety system is capable of mitigating the consequences of the selected abnormalities

  18. Role of TLR4 in the Modulation of Central Amygdala GABA Transmission by CRF Following Restraint Stress.

    Science.gov (United States)

    Varodayan, F P; Khom, S; Patel, R R; Steinman, M Q; Hedges, D M; Oleata, C S; Homanics, G E; Roberto, M; Bajo, M

    2018-01-04

    Stress induces neuroimmune responses via Toll-like receptor 4 (TLR4) activation. Here, we investigated the role of TLR4 in the effects of the stress peptide corticotropin-releasing factor (CRF) on GABAergic transmission in the central nucleus of the amygdala (CeA) following restraint stress. Tlr4 knock out (KO) and wild-type rats were exposed to no stress (naïve), a single restraint stress (1 h) or repeated restraint stress (1 h per day for 3 consecutive days). After 1 h recovery from the final stress session, whole-cell patch-clamp electrophysiology was used to investigate the effects of CRF (200 nM) on CeA GABAA-mediated spontaneous inhibitory postsynaptic currents (sIPSCs). TLR4 does not regulate baseline GABAergic transmission in the CeA of naive and stress-treated animals. However, CRF significantly increased the mean sIPSC frequencies (indicating enhanced GABA release) across all genotypes and stress treatments, except for the Tlr4 KO rats that experienced repeated restraint stress. Overall, our results suggest a limited role for TLR4 in CRF's modulation of CeA GABAergic synapses in naïve and single stress rats, though TLR4-deficient rats that experienced repeated psychological stress exhibit a blunted CRF cellular response. TLR4 has a limited role in CRF's activation of the CeA under basal conditions, but interacts with the CRF system to regulate GABAergic synapse function in animals that experience repeated psychological stress. © The Author(s) 2018. Medical Council on Alcohol and Oxford University Press. All rights reserved.

  19. Chemical restraint in routine clinical practice: a report from a general hospital psychiatric ward in Greece

    Directory of Open Access Journals (Sweden)

    Papamichael Georgios

    2011-02-01

    Full Text Available Abstract Background There is a dearth of studies regarding chemical restraint in routine clinical psychiatric practice. There may be wide variations between different settings and countries. Methods A retrospective study on chemical restraint was performed in the 11-bed psychiatric ward of the General Hospital of Arta, in northwestern Greece. All admissions over a 2-year-period (from March 2008 to March 2010 were examined. Results Chemical restraint was applied in 33 cases (10.5% of total admissions. From a total of 82 injections, 22 involved a benzodiazepine and/or levomepromazine, whereas 60 injections involved an antipsychotic agent, almost exclusively haloperidol (96.7% of cases, usually in combination with a benzodiazepine (61.7% of cases. In 36.4% of cases the patient was further subjected to restraint or seclusion. Conclusions In our unit, clinicians prefer the combined antipsychotic/benzodiazepine regimen for the management of patients' acute agitation and violent behaviour. Conventional antipsychotics are administrated almost exclusively and in a significant proportion of cases further coercive measures are applied. Studies on the practice of chemical restraint should be regularly performed in clinical settings.

  20. Survey and evaluation of inherent safety characteristics and passive safety systems for use in probabilistic safety analyses

    International Nuclear Information System (INIS)

    Wetzel, N.; Scharfe, A.

    1998-01-01

    The present report examines the possibilities and limits of a probabilistic safety analysis to evaluate passive safety systems and inherent safety characteristics. The inherent safety characteristics are based on physical principles, that together with the safety system lead to no damage. A probabilistic evaluation of the inherent safety characteristic is not made. An inventory of passive safety systems of accomplished nuclear power plant types in the Federal Republic of Germany was drawn up. The evaluation of the passive safety system in the analysis of the accomplished nuclear power plant types was examined. The analysis showed that the passive manner of working was always assumed to be successful. A probabilistic evaluation was not performed. The unavailability of the passive safety system was determined by the failure of active components which are necessary in order to activate the passive safety system. To evaluate the passive safety features in new concepts of nuclear power plants the AP600 from Westinghouse, the SBWR from General Electric and the SWR 600 from Siemens, were selected. Under these three reactor concepts, the SWR 600 is specially attractive because the safety features need no energy sources and instrumentation in this concept. First approaches for the assessment of the reliability of passively operating systems are summarized. Generally it can be established that the core melt frequency for the passive concepts AP600 and SBWR is advantageous in comparison to the probabilistic objectives from the European Pressurized Water Reactor (EPR). Under the passive concepts is the SWR 600 particularly interesting. In this concept the passive systems need no energy sources and instrumentation, and has active operational systems and active safety equipment. Siemens argues that with this concept the frequency of a core melt will be two orders of magnitude lower than for the conventional reactors. (orig.) [de

  1. Pine needle extract prevents hippocampal memory impairment in acute restraint stress mouse model.

    Science.gov (United States)

    Lee, Jin-Seok; Kim, Hyeong-Geug; Lee, Hye-Won; Kim, Won-Yong; Ahn, Yo-Chan; Son, Chang-Gue

    2017-07-31

    The Pinus densiflora leaf has been traditionally used to treat mental health disorders as a traditional Chinese medicine. Here we examined the ethnopharmacological relevance of pine needle on memory impairment caused by stress. To elucidate the possible modulatory actions of 30% ethanolic pine needle extract (PNE) on stress-induced hippocampal excitotoxicity, we adopted an acute restraint stress mouse model. Mice were orally administered with PNE (25, 50, or 100mg/kg) or ascorbic acid (100mg/kg) for 9 days, and were then subjected to restraint stress (6h/day) for 3 days (from experimental day 7-9). To evaluate spatial cognitive and memory function, the Morris water maze was performed during experimental days 5-9. Restraint stress induced the memory impairment (the prolonged escape latency and cumulative path-length, and reduced time spent in the target quadrant), and these effects were significantly prevented by PNE treatment. The levels of corticosterone and its receptor in the sera/hippocampus were increased by restraint stress, which was normalized by PNE treatment. Restraint stress elicited the hippocampal excitotoxicity, the inflammatory response and oxidative injury as demonstrated by the increased glutamate levels, altered levels of tumor necrosis factor (TNF)-α and imbalanced oxidant-antioxidant balance biomarkers. Two immunohistochemistry activities against glial fibrillary acidic protein (GFAP)-positive astrocytes and neuronal nuclei (NeuN)-positive neurons supported the finding of excitotoxicity especially in the cornu ammonis (CA)3 region of the hippocampus. Those alterations were notably attenuated by administration of PNE. The above findings showed that PNE has pharmacological properties that modulate the hippocampal excitotoxicity-derived memory impairment under severe stress conditions. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. 28 CFR 552.26 - Medical attention in use of force and application of restraints incidents.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Medical attention in use of force and application of restraints incidents. 552.26 Section 552.26 Judicial Administration BUREAU OF PRISONS... § 552.26 Medical attention in use of force and application of restraints incidents. (a) In immediate use...

  3. Does the concept of safety culture help or hinder systems thinking in safety?

    Science.gov (United States)

    Reiman, Teemu; Rollenhagen, Carl

    2014-07-01

    The concept of safety culture has become established in safety management applications in all major safety-critical domains. The idea that safety culture somehow represents a "systemic view" on safety is seldom explicitly spoken out, but nevertheless seem to linger behind many safety culture discourses. However, in this paper we argue that the "new" contribution to safety management from safety culture never really became integrated with classical engineering principles and concepts. This integration would have been necessary for the development of a more genuine systems-oriented view on safety; e.g. a conception of safety in which human, technological, organisational and cultural factors are understood as mutually interacting elements. Without of this integration, researchers and the users of the various tools and methods associated with safety culture have sometimes fostered a belief that "safety culture" in fact represents such a systemic view about safety. This belief is, however, not backed up by theoretical or empirical evidence. It is true that safety culture, at least in some sense, represents a holistic term-a totality of factors that include human, organisational and technological aspects. However, the departure for such safety culture models is still human and organisational factors rather than technology (or safety) itself. The aim of this paper is to critically review the various uses of the concept of safety culture as representing a systemic view on safety. The article will take a look at the concepts of culture and safety culture based on previous studies, and outlines in more detail the theoretical challenges in safety culture as a systems concept. The paper also presents recommendations on how to make safety culture more systemic. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. A smart base restraint for wind turbines to mitigate undesired effects due to structural vibrations

    DEFF Research Database (Denmark)

    Caterino, N.; Georgakis, Christos T.; Spizzuoco, M.

    2016-01-01

    Concerns in the last decades of the negative impact of the use of fossil fuels on the environment has lead to a boom in the production of wind turbines. To take advantage of the smoother stronger winds at height, wind turbine heights are progressively increasing. This has led to an increased demand...... to control tower forces. The application of a semi-active (SA) control system is herein proposed and discussed. Its aim is to limit bending moment demand at the base of a wind turbine by relaxing the base restraint of the turbine's tower, without increasing the top displacement. This is done thanks....... This smart restraint is made of a central smooth hinge, elastic springs and SA magnetorheological dampers driven by a control algorithm properly designed for the specific application. A commercial 105 m tall wind turbine has been assumed as a case study. Several numerical simulations have been performed...

  5. The aviation safety reporting system

    Science.gov (United States)

    Reynard, W. D.

    1984-01-01

    The aviation safety reporting system, an accident reporting system, is presented. The system identifies deficiencies and discrepancies and the data it provides are used for long term identification of problems. Data for planning and policy making are provided. The system offers training in safety education to pilots. Data and information are drawn from the available data bases.

  6. Dietary restraint in college women: fear of an imperfect fat self is stronger than hope of a perfect thin self.

    Science.gov (United States)

    Dalley, Simon E; Toffanin, Paolo; Pollet, Thomas V

    2012-09-01

    We predicted that the perceived likelihood of acquiring a hoped-for thin self would mediate perfectionistic strivings on dietary restraint, and that the perceived likelihood of acquiring a feared fat self would mediate perfectionistic concerns on dietary restraint. We also predicted that the mediation pathway from perfectionistic concerns to dietary restraint would have a greater impact than that from perfectionistic strivings. Participants were 222 female college students who reported their height and weight and completed measures of perfectionism, the likelihood of acquiring the feared fat and hoped-for thin selves, and dietary restraint. Statistical analyses revealed that the perceived likelihood of acquiring the feared fat self mediated both perfectionistic concerns and perfectionistic strivings on dietary restraint, and that the mediating pathway from perfectionistic concerns to dietary restraint was greater than that from perfectionistic strivings. Implications for future research and eating pathology interventions are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. NASA Aviation Safety Reporting System (ASRS)

    Science.gov (United States)

    Connell, Linda J.

    2017-01-01

    The NASA Aviation Safety Reporting System (ASRS) collects, analyzes, and distributes de-identified safety information provided through confidentially submitted reports from frontline aviation personnel. Since its inception in 1976, the ASRS has collected over 1.4 million reports and has never breached the identity of the people sharing their information about events or safety issues. From this volume of data, the ASRS has released over 6,000 aviation safety alerts concerning potential hazards and safety concerns. The ASRS processes these reports, evaluates the information, and provides selected de-identified report information through the online ASRS Database at http:asrs.arc.nasa.gov. The NASA ASRS is also a founding member of the International Confidential Aviation Safety Systems (ICASS) group which is a collection of other national aviation reporting systems throughout the world. The ASRS model has also been replicated for application to improving safety in railroad, medical, fire fighting, and other domains. This presentation will discuss confidential, voluntary, and non-punitive reporting systems and their advantages in providing information for safety improvements.

  8. Educational intervention on physical restraint use in long-term care facilities – Systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Shao-Huan Lan

    2017-08-01

    Full Text Available “Physical restraint” formerly used as a measure of protection for psychiatric patients is now widely used. However, existing studies showed that physical restraint not only has inadequate effect of protection but also has negative effects on residents. To analyzes the impact of educational program on the physical restraint use in long-term care facilities. Design: A systematic review with meta-analysis and meta-regression. Eight databases, including Cochrane Library, ProQuest, PubMed, EMBASE, EBSCO, Web of Science, Ovid Medline and Physiotherapy Evidence Database (PEDro, were searched up to January 2017. Eligible studies were classified by intervention and accessed for quality using the Quality Assessment Tool for quantitative studies. Sixteen research articles were eligible in the final review; 10 randomize control trail studies were included in the analysis. The meta-analysis revealed that the use of physical restraint was significantly less often in the experimental (education group (OR = 0.55, 95% CI: 0.39 to 0.78, p < 0.001 compared to the control group. Meta-regression revealed the period of post education would have decreased the effect of the restraint educational program (β: 0.08, p = 0.002; instead, the longer education period and more times of education would have a stronger effect of reducing the use of physical restraint (β: −0.07, p < 0.001; β: −0.04, p = 0.056. The educational program had an effect on the reduced use of physical restraint. The results of meta-regression suggest that long-term care facilities should provide a continuous education program of physical restraint for caregivers.

  9. Software for computer based systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2004-01-01

    Computer based systems are of increasing importance to safety in nuclear power plants as their use in both new and older plants is rapidly increasing. They are used both in safety related applications, such as some functions of the process control and monitoring systems, as well as in safety critical applications, such as reactor protection or actuation of safety features. The dependability of computer based systems important to safety is therefore of prime interest and should be ensured. With current technology, it is possible in principle to develop computer based instrumentation and control systems for systems important to safety that have the potential for improving the level of safety and reliability with sufficient dependability. However, their dependability can be predicted and demonstrated only if a systematic, fully documented and reviewable engineering process is followed. Although a number of national and international standards dealing with quality assurance for computer based systems important to safety have been or are being prepared, internationally agreed criteria for demonstrating the safety of such systems are not generally available. It is recognized that there may be other ways of providing the necessary safety demonstration than those recommended here. The basic requirements for the design of safety systems for nuclear power plants are provided in the Requirements for Design issued in the IAEA Safety Standards Series.The IAEA has issued a Technical Report to assist Member States in ensuring that computer based systems important to safety in nuclear power plants are safe and properly licensed. The report provides information on current software engineering practices and, together with relevant standards, forms a technical basis for this Safety Guide. The objective of this Safety Guide is to provide guidance on the collection of evidence and preparation of documentation to be used in the safety demonstration for the software for computer based

  10. Software for computer based systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2005-01-01

    Computer based systems are of increasing importance to safety in nuclear power plants as their use in both new and older plants is rapidly increasing. They are used both in safety related applications, such as some functions of the process control and monitoring systems, as well as in safety critical applications, such as reactor protection or actuation of safety features. The dependability of computer based systems important to safety is therefore of prime interest and should be ensured. With current technology, it is possible in principle to develop computer based instrumentation and control systems for systems important to safety that have the potential for improving the level of safety and reliability with sufficient dependability. However, their dependability can be predicted and demonstrated only if a systematic, fully documented and reviewable engineering process is followed. Although a number of national and international standards dealing with quality assurance for computer based systems important to safety have been or are being prepared, internationally agreed criteria for demonstrating the safety of such systems are not generally available. It is recognized that there may be other ways of providing the necessary safety demonstration than those recommended here. The basic requirements for the design of safety systems for nuclear power plants are provided in the Requirements for Design issued in the IAEA Safety Standards Series.The IAEA has issued a Technical Report to assist Member States in ensuring that computer based systems important to safety in nuclear power plants are safe and properly licensed. The report provides information on current software engineering practices and, together with relevant standards, forms a technical basis for this Safety Guide. The objective of this Safety Guide is to provide guidance on the collection of evidence and preparation of documentation to be used in the safety demonstration for the software for computer based

  11. Software for computer based systems important to safety in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2000-01-01

    Computer based systems are of increasing importance to safety in nuclear power plants as their use in both new and older plants is rapidly increasing. They are used both in safety related applications, such as some functions of the process control and monitoring systems, as well as in safety critical applications, such as reactor protection or actuation of safety features. The dependability of computer based systems important to safety is therefore of prime interest and should be ensured. With current technology, it is possible in principle to develop computer based instrumentation and control systems for systems important to safety that have the potential for improving the level of safety and reliability with sufficient dependability. However, their dependability can be predicted and demonstrated only if a systematic, fully documented and reviewable engineering process is followed. Although a number of national and international standards dealing with quality assurance for computer based systems important to safety have been or are being prepared, internationally agreed criteria for demonstrating the safety of such systems are not generally available. It is recognized that there may be other ways of providing the necessary safety demonstration than those recommended here. The basic requirements for the design of safety systems for nuclear power plants are provided in the Requirements for Design issued in the IAEA Safety Standards Series.The IAEA has issued a Technical Report to assist Member States in ensuring that computer based systems important to safety in nuclear power plants are safe and properly licensed. The report provides information on current software engineering practices and, together with relevant standards, forms a technical basis for this Safety Guide. The objective of this Safety Guide is to provide guidance on the collection of evidence and preparation of documentation to be used in the safety demonstration for the software for computer based

  12. Jefferson Lab IEC 61508/61511 Safety PLC Based Safety System

    International Nuclear Information System (INIS)

    Mahoney, Kelly; Robertson, Henry

    2009-01-01

    This paper describes the design of the new 12 GeV Upgrade Personnel Safety System (PSS) at the Thomas Jefferson National Accelerator Facility (TJNAF). The new PSS design is based on the implementation of systems designed to meet international standards IEC61508 and IEC 61511 for programmable safety systems. In order to meet the IEC standards, TJNAF engineers evaluated several SIL 3 Safety PLCs before deciding on an optimal architecture. In addition to hardware considerations, software quality standards and practices must also be considered. Finally, we will discuss R and D that may lead to both high safety reliability and high machine availability that may be applicable to future accelerators such as the ILC.

  13. Intermediate probabilistic safety assessment approach for safety critical digital systems

    International Nuclear Information System (INIS)

    Taeyong, Sung; Hyun Gook, Kang

    2001-01-01

    Even though the conventional probabilistic safety assessment methods are immature for applying to microprocessor-based digital systems, practical needs force to apply it. In the Korea, UCN 5 and 6 units are being constructed and Korean Next Generation Reactor is being designed using the digital instrumentation and control equipment for the safety related functions. Korean regulatory body requires probabilistic safety assessment. This paper analyzes the difficulties on the assessment of digital systems and suggests an intermediate framework for evaluating their safety using fault tree models. The framework deals with several important characteristics of digital systems including software modules and fault-tolerant features. We expect that the analysis result will provide valuable design feedback. (authors)

  14. Technical self reliance of digital safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Dong Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Kook Hun [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of); Choi, Seung Gap [POSCON, Pohang (Korea, Republic of)

    2009-04-15

    This paper summarizes the development results of the Korea Nuclear Instrumentation and Control System (KNICS) project sponsored by the Korean government. In this project, Man Machine Interface System (MMIS) architecture, two digital platforms, and several control systems are developed. One platform is a programmable Logic Controller (PLC) for a safety system and another platform is a Distributed Control System (DCS) for a non safety system. With the POSAFE Q PLC, a Reactor Protection System (RPS) and an Engineered Safety Feature Component Control System (ESF CCS) are developed. A Power Control System (PCS) is developed based on the DCS. The safety grade platform and the digital safety systems obtained approval for the Topical Report from the Korean regulatory body in February of 2009. Also a Korean utility and a vendor company determined KNICS results to apply them to the planned Nuclear Power Plant (NPP) in March 2009. This paper introduces the technical self reliance experiences of the safety grade platform and the digital safety systems developed in the KNICS R and D project.

  15. Integrating system safety into the basic systems engineering process

    Science.gov (United States)

    Griswold, J. W.

    1971-01-01

    The basic elements of a systems engineering process are given along with a detailed description of what the safety system requires from the systems engineering process. Also discussed is the safety that the system provides to other subfunctions of systems engineering.

  16. Coping with budget restraint in a Scandinavian welfare state

    DEFF Research Database (Denmark)

    Nielsen, Annemette Ljungdalh; Holm, Lotte; Lund, Thomas Bøker

    2015-01-01

    The purpose of this study was to investigate how different types of households react to experiences of food budget restraint in Denmark. The study applied a mixed method design, based on survey data and on qualitative interviews. The qualitative data source consisted of interviews with 30...... institute GfK ConsumerTracking Scandinavia. Using both data sources the study explored how shopping, storing, cooking and eating practices changed as a consequence of experienced restraints on the food budget. The quantitative results revealed how differences in terms of application of various types...... of strategies are related to different levels of food budget restrictions. Strategies applied to storing and cooking food in more efficient manners were widely practiced across all groups. Strategies which affected eating experiences, such as compromising the tastiness of food and giving up social ties involved...

  17. Programmable Electronic Safety Systems

    International Nuclear Information System (INIS)

    Parry, R.

    1993-05-01

    Traditionally safety systems intended for protecting personnel from electrical and radiation hazards at particle accelerator laboratories have made extensive use of electromechanical relays. These systems have the advantage of high reliability and allow the designer to easily implement failsafe circuits. Relay based systems are also typically simple to design, implement, and test. As systems, such as those presently under development at the Superconducting Super Collider Laboratory (SSCL), increase in size, and the number of monitored points escalates, relay based systems become cumbersome and inadequate. The move toward Programmable Electronic Safety Systems is becoming more widespread and accepted. In developing these systems there are numerous precautions the designer must be concerned with. Designing fail-safe electronic systems with predictable failure states is difficult at best. Redundancy and self-testing are prime examples of features that should be implemented to circumvent and/or detect failures. Programmable systems also require software which is yet another point of failure and a matter of great concern. Therefore the designer must be concerned with both hardware and software failures and build in the means to assure safe operation or shutdown during failures. This paper describes features that should be considered in developing safety systems and describes a system recently installed at the Accelerator Systems String Test (ASST) facility of the SSCL

  18. Acute restraint stress decreases c-fos immunoreactivity in hilar mossy cells of the adult dentate gyrus

    Science.gov (United States)

    Moretto, Jillian N.; Duffy, Áine M.

    2017-01-01

    Although a great deal of information is available about the circuitry of the mossy cells (MCs) of the dentate gyrus (DG) hilus, their activity in vivo is not clear. The immediate early gene c-fos can be used to gain insight into the activity of MCs in vivo, because c-fos protein expression reflects increased neuronal activity. In prior work, it was identified that control rats that were perfusion-fixed after removal from their home cage exhibited c-fos immunoreactivity (ir) in the DG in a spatially stereotyped pattern: ventral MCs and dorsal granule cells (GCs) expressed c-fos protein (Duffy et al., Hippocampus 23:649–655, 2013). In this study, we hypothesized that restraint stress would alter c-fos-ir, because MCs express glucocorticoid type 2 receptors and the DG is considered to be involved in behaviors related to stress or anxiety. We show that acute restraint using a transparent nose cone for just 10 min led to reduced c-fos-ir in ventral MCs compared to control rats. In these comparisons, c-fos-ir was evaluated 30 min after the 10 min-long period of restraint, and if evaluation was later than 30 min c-fos-ir was no longer suppressed. Granule cells (GCs) also showed suppressed c-fos-ir after acute restraint, but it was different than MCs, because the suppression persisted for over 30 min after the restraint. We conclude that c-fos protein expression is rapidly and transiently reduced in ventral hilar MCs after a brief period of restraint, and suppressed longer in dorsal GCs. PMID:28190104

  19. Quality of life of nursing-home residents with dementia subject to surveillance technology versus physical restraints: an explorative study.

    Science.gov (United States)

    Te Boekhorst, S; Depla, M F I A; Francke, A L; Twisk, J W R; Zwijsen, S A; Hertogh, C M P M

    2013-04-01

    As physical restraints should only be used in exceptional cases, there is an urgent need for alternatives to restraint use. Surveillance technology could be such an alternative. This study explored whether nursing-home residents with dementia subjected to surveillance technology had better quality of life scores for mood, behavioral and societal dimensions than residents with physical restraints. Quality of life was assessed longitudinally, with three measurements in six psychogeriatric nursing homes of residents with surveillance technology (n = 170) and residents with physical restraints (n = 22). QUALIDEM subscales were used to measure five dimensions of quality of life. Multilevel longitudinal univariate and multivariate regression techniques were used to analyze the data. Because physical restraints were almost exclusively used in residents with low activities of daily living (ADL) independency (18 of the 22), we restricted the regression analyses to residents with a Barthel Index score ≤ 5 (overall n = 53). Univariate results showed that highly ADL-dependent residents with surveillance technology had significantly more positive affect than highly ADL-dependent residents with physical restraints. However, this difference proved to be no longer significant after adjustment for the confounders: age, sex and stage of dementia. Quality of life of highly ADL-dependent nursing-home residents with dementia seems to be unrelated to the use of surveillance technology as opposed to physical restraints. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Status of voluntary restraint

    Energy Technology Data Exchange (ETDEWEB)

    Aarts, W. [SWOKA Institute for Strategic Consumer Behaviour, Leiden (Netherlands)

    2000-05-01

    Do people enjoying a higher status, especially those with a higher education, constrain their consumption more than others? In general, higher status and high levels of consumption go hand in hand. But the greater availability of luxury goods has led to a decline in their exclusivity. Since environmental awareness has increased, a countercurrent may be possible. It is possible that certain high status groups, the environmentally aware trendsetters, can now be distinguished by their voluntary restraint rather than by their conspicuous consumption. This hypothesis formed the basis for a sociological doctoral project at the University of Amsterdam. The research was conducted under the umbrella of the National Research Programme on Global Air Pollution and Climate Change.

  1. Dietary restraint and impulsivity modulate neural responses to food in adolescents with obesity and healthy adolescents.

    Science.gov (United States)

    Hofmann, Johannes; Ardelt-Gattinger, Elisabeth; Paulmichl, Katharina; Weghuber, Daniel; Blechert, Jens

    2015-11-01

    Despite alarming prevalence rates, surprisingly little is known about neural mechanisms underlying eating behavior in juveniles with obesity. To simulate reactivity to modern food environments, event-related potentials (ERP) to appetizing food images (relative to control images) were recorded in adolescents with obesity and healthy adolescents. Thirty-four adolescents with obesity (patients) and 24 matched healthy control adolescents watched and rated standardized food and object images during ERP recording. Personality (impulsivity) and eating styles (trait craving and dietary restraint) were assessed as potential moderators. Food relative to object images triggered larger early (P100) and late (P300) ERPs. More impulsive individuals had considerably larger food-specific P100 amplitudes in both groups. Controls with higher restraint scores showed reduced food-specific P300 amplitudes and subjective palatability ratings whereas patients with higher restraint scores showed increased P300 and palatability ratings. This first ERP study in adolescents with obesity and controls revealed impulsivity as a general risk factor in the current obesogenic environment by increasing food-cue salience. Dietary restraint showed paradoxical effects in patients, making them more vulnerable to visual food-cues. Salutogenic therapeutic approaches that deemphasize strict dietary restraint and foster healthy food choice might reduce such paradoxical effects. © 2015 The Obesity Society.

  2. Psychological assessment of acute schizophrenia patients who experienced seclusion either alone or in combination with restraint.

    Science.gov (United States)

    Eguchi, Rika; Onozuka, Daisuke; Ikeda, Kouji; Kuroda, Kenji; Ieiri, Ichiro; Hagihara, Akihito

    2018-05-01

    Objective Numerous studies on the effects of seclusion and/or restraint in acute psychiatric treatment have reported both positive and negative effects. However, no studies to date have evaluated the effects of seclusion and/or restraint on schizophrenia patients using a rating scale. Thus, to examine the effects of seclusion and/or restraint on schizophrenia patients, we used the Brief Psychiatric Rating Scale and assessed the psychological condition of patients. Methods Factor analysis was conducted to create subscales of Brief Psychiatric Rating Scale, and psychiatric changes were assessed with respect to each subscale using multiple logistic regression analyses. Analyses were performed on three groups (i.e. entire, higher functioning, and lower functioning groups) involving a total of 1559 schizophrenia patients aged 18 to 65 years. Results In the entire and lower functioning groups, seclusion was a significant predictor of improvements related to the "hostility/suspiciousness" subscale. Seclusion combined with restraint was associated with improvements related to the "psychosis/thinking disorder" subscale. In the higher functioning group, there were no significant predictors. Conclusions It is implied that seclusion and/or restraint is related to improved psychiatric symptoms only among patients whose functioning is impaired. To verify the present findings, further studies involving multiple sites and additional psychiatric measures are necessary.

  3. 28 CFR 552.24 - Use of four-point restraints.

    Science.gov (United States)

    2010-07-01

    ... beyond eight hours requires the supervision of qualified health personnel. Mental health and qualified... Section 552.24 Judicial Administration BUREAU OF PRISONS, DEPARTMENT OF JUSTICE INSTITUTIONAL MANAGEMENT...-point restraints, qualified health personnel shall initially assess the inmate to ensure appropriate...

  4. Dietary restraint of 5-year-old girls: Associations with internalization of the thin ideal and maternal, media, and peer influences.

    Science.gov (United States)

    Damiano, Stephanie R; Paxton, Susan J; Wertheim, Eleanor H; McLean, Siân A; Gregg, Karen J

    2015-12-01

    Understanding socio-cultural factors associated with the development of dieting tendencies is important for preventing future disordered eating. We explored individual and socio-cultural factors associated with weight-focussed dietary restraint tendencies (described as dietary restraint) in 5-year-old girls. Participants were 111 5-year-old girls and 109 of their mothers. Girls were interviewed about their dietary restraint, body image, appearance ideals, positive weight bias (attributing positive characteristics to thinner figures), and peer conversations. Mothers completed self-report questionnaires assessing dietary restraint and appearance ideals, as well as measures reporting on their daughter's media exposure and peer appearance interest. Thirty-four percent of girls reported at least a moderate level of dietary restraint. While most girls were satisfied with their body size, half showed some internalization of the thin ideal. Girls' dietary restraint was correlated with weight bias favoring thinner bodies, and greater internalization of the thin ideal, media exposure, and appearance conversations with peers. Media exposure and appearance conversations were the strongest predictors of dietary restraint. These cross-sectional findings suggest that the socio-cultural environment of young girls may be important in the very early development of unhealthy dieting tendencies. Longitudinal research is necessary to identify whether these are prospective risk factors. © 2015 Wiley Periodicals, Inc.

  5. Considerations on nuclear reactor passive safety systems

    International Nuclear Information System (INIS)

    2016-01-01

    After having indicated some passive safety systems present in electronuclear reactors (control bars, safety injection system accumulators, reactor cooling after stoppage, hydrogen recombination systems), this report recalls the main characteristics of passive safety systems, and discusses the main issues associated with the assessment of new passive systems (notably to face a sustained loss of electric supply systems or of cold water source) and research axis to be developed in this respect. More precisely, the report comments the classification of safety passive systems as it is proposed by the IAEA, outlines and comments specific aspects of these systems regarding their operation and performance. The next part discusses the safety approach, the control of performance of safety passive systems, issues related to their reliability, and the expected contribution of R and D (for example: understanding of physical phenomena which have an influence of these systems, capacities of simulation of these phenomena, needs of experimentations to validate simulation codes)

  6. Behavioral Emergency Response Team: Implementation Improves Patient Safety, Staff Safety, and Staff Collaboration.

    Science.gov (United States)

    Zicko, Cdr Jennifer M; Schroeder, Lcdr Rebecca A; Byers, Cdr William S; Taylor, Lt Adam M; Spence, Cdr Dennis L

    2017-10-01

    Staff members working on our nonmental health (non-MH) units (i.e., medical-surgical [MS] units) were not educated in recognizing or deescalating behavioral emergencies. Published evidence suggests a behavioral emergency response team (BERT) composed of MH experts who assist with deescalating behavioral emergencies may be beneficial in these situations. Therefore, we sought to implement a BERT on the inpatient non-MH units at our military treatment facility. The objectives of this evidence-based practice process improvement project were to determine how implementation of a BERT affects staff and patient safety and to examine nursing staffs' level of knowledge, confidence, and support in caring for psychiatric patients and patients exhibiting behavioral emergencies. A BERT was piloted on one MS unit for 5 months and expanded to two additional units for 3 months. Pre- and postimplementation staff surveys were conducted, and the number of staff assaults and injuries, restraint usage, and security intervention were compared. The BERT responded to 17 behavioral emergencies. The number of assaults decreased from 10 (pre) to 1 (post); security intervention decreased from 14 to 1; and restraint use decreased from 8 to 1. MS staffs' level of BERT knowledge and rating of support between MH staff and their staff significantly increased. Both MS and MH nurses rated the BERT as supportive and effective. A BERT can assist with deescalating behavioral emergencies, and improve staff collaboration and patient and staff safety. © 2017 Sigma Theta Tau International.

  7. Nerve growth factor stimulates axon outgrowth through negative regulation of growth cone actomyosin restraint of microtubule advance.

    Science.gov (United States)

    Turney, Stephen G; Ahmed, Mostafa; Chandrasekar, Indra; Wysolmerski, Robert B; Goeckeler, Zoe M; Rioux, Robert M; Whitesides, George M; Bridgman, Paul C

    2016-02-01

    Nerve growth factor (NGF) promotes growth, differentiation, and survival of sensory neurons in the mammalian nervous system. Little is known about how NGF elicits faster axon outgrowth or how growth cones integrate and transform signal input to motor output. Using cultured mouse dorsal root ganglion neurons, we found that myosin II (MII) is required for NGF to stimulate faster axon outgrowth. From experiments inducing loss or gain of function of MII, specific MII isoforms, and vinculin-dependent adhesion-cytoskeletal coupling, we determined that NGF causes decreased vinculin-dependent actomyosin restraint of microtubule advance. Inhibition of MII blocked NGF stimulation, indicating the central role of restraint in directed outgrowth. The restraint consists of myosin IIB- and IIA-dependent processes: retrograde actin network flow and transverse actin bundling, respectively. The processes differentially contribute on laminin-1 and fibronectin due to selective actin tethering to adhesions. On laminin-1, NGF induced greater vinculin-dependent adhesion-cytoskeletal coupling, which slowed retrograde actin network flow (i.e., it regulated the molecular clutch). On fibronectin, NGF caused inactivation of myosin IIA, which negatively regulated actin bundling. On both substrates, the result was the same: NGF-induced weakening of MII-dependent restraint led to dynamic microtubules entering the actin-rich periphery more frequently, giving rise to faster elongation. © 2016 Turney et al. This article is distributed by The American Society for Cell Biology under license from the author(s). Two months after publication it is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  8. System safety engineering analysis handbook

    Science.gov (United States)

    Ijams, T. E.

    1972-01-01

    The basic requirements and guidelines for the preparation of System Safety Engineering Analysis are presented. The philosophy of System Safety and the various analytic methods available to the engineering profession are discussed. A text-book description of each of the methods is included.

  9. Testosterone depletion increases the susceptibility of brain tissue to oxidative damage in a restraint stress mouse model.

    Science.gov (United States)

    Son, Seung-Wan; Lee, Jin-Seok; Kim, Hyeong-Geug; Kim, Dong-Woon; Ahn, Yo-Chan; Son, Chang-Gue

    2016-01-01

    Among sex hormones, estrogen is particularly well known to act as neuroprotective agent. Unlike estrogen, testosterone has not been well investigated in regard to its effects on the brain, especially under psychological stress. To investigate the role of testosterone in oxidative brain injuries under psychological stress, we adapted an orchiectomy and restraint stress model. BALB/c mice were subjected to either an orchiectomy or sham operation. After allowing 15 days for recovery, mice were re-divided into four groups according to exposure of restraint stress: sham, sham plus stress, orchiectomy, and orchiectomy plus stress. Serum testosterone was undetectable in orchiectomized groups and restraint-induced stress significantly reduced testosterone levels in sham plus stress group. The serum levels of corticosterone and adrenaline were notably elevated by restraint stress, and these elevated hormones were markedly augmented by orchiectomy. Two oxidative stressors and biomarkers for lipid and protein peroxidation were significantly increased in the cerebral cortex and hippocampus by restraint stress, while the reverse pattern was observed in antioxidant enzymes. These results were supported by histopathological findings, with 4-hydroxynonenal staining for oxidative injury and Fluoro-Jade B staining showing the degenerating neurons. The aforementioned patterns of oxidative injury were accelerated by orchiectomy. These findings strongly suggest the conclusion that testosterone exerts a protective effect against oxidative brain damage, especially under stressed conditions. Unlike estrogen, the effects of testosterone on the brain have not been thoroughly investigated. In order to investigate the role of testosterone in oxidative brain injuries under psychological stress, we adapted an orchiectomy and restraint stress model. Orchiectomy markedly augmented the restraint stress-induced elevation of serum corticosterone and adrenaline levels as well as oxidative alterations

  10. Safety performance monitoring of autonomous marine systems

    International Nuclear Information System (INIS)

    Thieme, Christoph A.; Utne, Ingrid B.

    2017-01-01

    The marine environment is vast, harsh, and challenging. Unanticipated faults and events might lead to loss of vessels, transported goods, collected scientific data, and business reputation. Hence, systems have to be in place that monitor the safety performance of operation and indicate if it drifts into an intolerable safety level. This article proposes a process for developing safety indicators for the operation of autonomous marine systems (AMS). The condition of safety barriers and resilience engineering form the basis for the development of safety indicators, synthesizing and further adjusting the dual assurance and the resilience based early warning indicator (REWI) approaches. The article locates the process for developing safety indicators in the system life cycle emphasizing a timely implementation of the safety indicators. The resulting safety indicators reflect safety in AMS operation and can assist in planning of operations, in daily operational decision-making, and identification of improvements. Operation of an autonomous underwater vehicle (AUV) exemplifies the process for developing safety indicators and their implementation. The case study shows that the proposed process leads to a comprehensive set of safety indicators. It is expected that application of the resulting safety indicators consequently will contribute to safer operation of current and future AMS. - Highlights: • Process for developing safety indicators for autonomous marine systems. • Safety indicators based on safety barriers and resilience thinking. • Location of the development process in the system lifecycle. • Case study on AUV demonstrating applicability of the process.

  11. The application of viscous dampers as pipe restraints

    International Nuclear Information System (INIS)

    Keowen, R.S.; Hueffmann, G.; Mays, B.; Rencher, D.

    1993-01-01

    Dynamic loading of power generation piping systems may result in nonpermissable deflections and stresses. Fatigue failure translate to increased maintenance costs and possible lost revenue. Undesirable loading can occur due to external events such as earthquakes and internal events such as water and steam hammer, two-phase flow and cavitation. Sway braces and snubbers have been employed to reduce the negative effects of piping motion in emergency cases, however, repetitive loading due to internal events has caused premature wear and failure. Visco elastic dampers, however, have proven to be piping response due to slugging, steam hammer and other repetitive loads. Functional and modeling aspects of visco elastic dampers are discussed, experimental evidence of their effectiveness in a steam hammer application is presented and examples of primary coolant loop restraint applications are illustrated

  12. 78 FR 29392 - Embedded Digital Devices in Safety-Related Systems, Systems Important to Safety, and Items Relied...

    Science.gov (United States)

    2013-05-20

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0098] Embedded Digital Devices in Safety-Related Systems, Systems Important to Safety, and Items Relied on for Safety AGENCY: Nuclear Regulatory Commission. ACTION... (NRC) is issuing for public comment Draft Regulatory Issue Summary (RIS) 2013-XX, ``Embedded Digital...

  13. Dieting in Moderation: The Role of Dietary Restraint in the Relationship between Body Dissatisfaction and Psychological Well-being.

    Science.gov (United States)

    Tiggemann, M

    1997-10-01

    This study demonstrates the substantial conceptual consequences in distinguishing a variable's role as a moderator as opposed to a mediator. In particular, the study investigates the role of dietary restraint in the relationship between body dissatisfaction and psychological well-being. Path analyses showed that, in addition to its mediating role, dietary restraint has a moderating role, such that there is a stronger relationship between body dissatisfaction and psychological well-being when dietary restraint is high than when dietary restraint is low. In contrast, gender had only a direct effect on weight dissatisfaction. It was concluded that the same processes occur for both men and for women, whereby it is the individuals who diet who suffer loss of psychological well-being.

  14. The Evolution of System Safety at NASA

    Science.gov (United States)

    Dezfuli, Homayoon; Everett, Chris; Groen, Frank

    2014-01-01

    The NASA system safety framework is in the process of change, motivated by the desire to promote an objectives-driven approach to system safety that explicitly focuses system safety efforts on system-level safety performance, and serves to unify, in a purposeful manner, safety-related activities that otherwise might be done in a way that results in gaps, redundancies, or unnecessary work. An objectives-driven approach to system safety affords more flexibility to determine, on a system-specific basis, the means by which adequate safety is achieved and verified. Such flexibility and efficiency is becoming increasingly important in the face of evolving engineering modalities and acquisition models, where, for example, NASA will increasingly rely on commercial providers for transportation services to low-earth orbit. A key element of this objectives-driven approach is the use of the risk-informed safety case (RISC): a structured argument, supported by a body of evidence, that provides a compelling, comprehensible and valid case that a system is or will be adequately safe for a given application in a given environment. The RISC addresses each of the objectives defined for the system, providing a rational basis for making informed risk acceptance decisions at relevant decision points in the system life cycle.

  15. Evaluation of Life Sciences Glovebox (LSG) and Multi-Purpose Crew Restraint Concepts

    Science.gov (United States)

    Whitmore, Mihriban

    2005-01-01

    Within the scope of the Multi-purpose Crew Restraints for Long Duration Spaceflights project, funded by Code U, it was proposed to conduct a series of evaluations on the ground and on the KC-135 to investigate the human factors issues concerning confined/unique workstations, such as the design of crew restraints. The usability of multiple crew restraints was evaluated for use with the Life Sciences Glovebox (LSG) and for performing general purpose tasks. The purpose of the KC-135 microgravity evaluation was to: (1) to investigate the usability and effectiveness of the concepts developed, (2) to gather recommendations for further development of the concepts, and (3) to verify the validity of the existing requirements. Some designs had already been tested during a March KC-135 evaluation, and testing revealed the need for modifications/enhancements. This flight was designed to test the new iterations, as well as some new concepts. This flight also involved higher fidelity tasks in the LSG, and the addition of load cells on the gloveports.

  16. Software Quality Assurance for Nuclear Safety Systems

    International Nuclear Information System (INIS)

    Sparkman, D R; Lagdon, R

    2004-01-01

    The US Department of Energy has undertaken an initiative to improve the quality of software used to design and operate their nuclear facilities across the United States. One aspect of this initiative is to revise or create new directives and guides associated with quality practices for the safety software in its nuclear facilities. Safety software includes the safety structures, systems, and components software and firmware, support software and design and analysis software used to ensure the safety of the facility. DOE nuclear facilities are unique when compared to commercial nuclear or other industrial activities in terms of the types and quantities of hazards that must be controlled to protect workers, public and the environment. Because of these differences, DOE must develop an approach to software quality assurance that ensures appropriate risk mitigation by developing a framework of requirements that accomplishes the following goals: (sm b ullet) Ensures the software processes developed to address nuclear safety in design, operation, construction and maintenance of its facilities are safe (sm b ullet) Considers the larger system that uses the software and its impacts (sm b ullet) Ensures that the software failures do not create unsafe conditions Software designers for nuclear systems and processes must reduce risks in software applications by incorporating processes that recognize, detect, and mitigate software failure in safety related systems. It must also ensure that fail safe modes and component testing are incorporated into software design. For nuclear facilities, the consideration of risk is not necessarily sufficient to ensure safety. Systematic evaluation, independent verification and system safety analysis must be considered for software design, implementation, and operation. The software industry primarily uses risk analysis to determine the appropriate level of rigor applied to software practices. This risk-based approach distinguishes safety

  17. 77 FR 70409 - System Safety Program

    Science.gov (United States)

    2012-11-26

    ...-0060, Notice No. 2] 2130-AC31 System Safety Program AGENCY: Federal Railroad Administration (FRA... rulemaking (NPRM) published on September 7, 2012, FRA proposed regulations to require commuter and intercity passenger railroads to develop and implement a system safety program (SSP) to improve the safety of their...

  18. Modelling safety of multistate systems with ageing components

    Energy Technology Data Exchange (ETDEWEB)

    Kołowrocki, Krzysztof; Soszyńska-Budny, Joanna [Gdynia Maritime University, Department of Mathematics ul. Morska 81-87, Gdynia 81-225 Poland (Poland)

    2016-06-08

    An innovative approach to safety analysis of multistate ageing systems is presented. Basic notions of the ageing multistate systems safety analysis are introduced. The system components and the system multistate safety functions are defined. The mean values and variances of the multistate systems lifetimes in the safety state subsets and the mean values of their lifetimes in the particular safety states are defined. The multi-state system risk function and the moment of exceeding by the system the critical safety state are introduced. Applications of the proposed multistate system safety models to the evaluation and prediction of the safty characteristics of the consecutive “m out of n: F” is presented as well.

  19. Modelling safety of multistate systems with ageing components

    International Nuclear Information System (INIS)

    Kołowrocki, Krzysztof; Soszyńska-Budny, Joanna

    2016-01-01

    An innovative approach to safety analysis of multistate ageing systems is presented. Basic notions of the ageing multistate systems safety analysis are introduced. The system components and the system multistate safety functions are defined. The mean values and variances of the multistate systems lifetimes in the safety state subsets and the mean values of their lifetimes in the particular safety states are defined. The multi-state system risk function and the moment of exceeding by the system the critical safety state are introduced. Applications of the proposed multistate system safety models to the evaluation and prediction of the safty characteristics of the consecutive “m out of n: F” is presented as well.

  20. Programmable electronic safety systems

    International Nuclear Information System (INIS)

    Parry, R.R.

    1993-01-01

    Traditionally safety systems intended for protecting personnel from electrical and radiation hazards at particle accelerator laboratories have made extensive use of electromechanical relays. These systems have the advantage of high reliability and allow the designer to easily implement fail-safe circuits. Relay based systems are also typically simple to design, implement, and test. As systems, such as those presently under development at the Superconducting Super Collider Laboratory (SSCL), increase in size, and the number of monitored points escalates, relay based systems become cumbersome and inadequate. The move toward Programmable Electronic Safety Systems is becoming more widespread and accepted. In developing these systems there are numerous precautions the designer must be concerned with. Designing fail-safe electronic systems with predictable failure states is difficult at best. Redundancy and self-testing are prime examples of features that should be implemented to circumvent and/or detect failures. Programmable systems also require software which is yet another point of failure and a matter of great concern. Therefore the designer must be concerned with both hardware and software failures and build in the means to assure safe operation or shutdown during failures. This paper describes features that should be considered in developing safety systems and describes a system recently installed at the Accelerator Systems String Test (ASST) facility of the SSCL

  1. System safety education focused on industrial engineering

    Science.gov (United States)

    Johnston, W. L.; Morris, R. S.

    1971-01-01

    An educational program, designed to train students with the specific skills needed to become safety specialists, is described. The discussion concentrates on application, selection, and utilization of various system safety analytical approaches. Emphasis is also placed on the management of a system safety program, its relationship with other disciplines, and new developments and applications of system safety techniques.

  2. Retrospective analysis of detomidine infusion for standing chemical restraint in 51 horses.

    Science.gov (United States)

    Wilson, D V; Bohart, G V; Evans, A T; Robertson, S; Rondenay, Y

    2002-01-01

    To assess the effectiveness of a detomidine infusion technique to provide standing chemical restraint in the horse. Retrospective study. Fifty-one adult horses aged 9.5 ± 6.9 years (range 1-23 years) and weighing 575 ± 290.3 kg. Records of horses presented to our clinic over a 3-year period in which a detomidine infusion was used to provide standing chemical restraint were reviewed. Information relating to the types of procedure performed, duration of infusion, drug dosages and adjunct drugs administered was retrieved. Detomidine was administered as an initial bolus loading dose (mean ± SD) of 7.5 ± 1.87 μg kg -1 . The initial infusion rate was 0.6 μg kg -1 minute -1 , and this was halved every 15 minutes. The duration of the infusion ranged from 20 to 135 minutes. Twenty horses received additional detomidine or butorphanol during the procedure. All horses undergoing surgery received local anesthesia or epidural analgesia in addition to the detomidine infusion. A wide variety of procedures were performed in these horses. Detomidine administered by infusion provides prolonged periods of chemical restraint in standing horses. Supplemental sedatives or analgesics may be needed in horses undergoing surgery. An effective method that provides prolonged periods of chemical restraint in standing horses is described. The infusion alone did not provide sufficient analgesia for surgery and a significant proportion of animals required supplemental sedatives and analgesics. Copyright © 2002 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  3. Radiation safety systems at the NSLS

    International Nuclear Information System (INIS)

    Dickinson, T.

    1987-04-01

    This report describes design principles that were used to establish the radiation safety systems at the National Synchrotron Light Source. The author described existing safety systems and the history of partial system failures. 1 fig

  4. Utilization of paramagnetic relaxation enhancements for high-resolution NMR structure determination of a soluble loop-rich protein with sparse NOE distance restraints

    International Nuclear Information System (INIS)

    Furuita, Kyoko; Kataoka, Saori; Sugiki, Toshihiko; Hattori, Yoshikazu; Kobayashi, Naohiro; Ikegami, Takahisa; Shiozaki, Kazuhiro; Fujiwara, Toshimichi; Kojima, Chojiro

    2015-01-01

    NMR structure determination of soluble proteins depends in large part on distance restraints derived from NOE. In this study, we examined the impact of paramagnetic relaxation enhancement (PRE)-derived distance restraints on protein structure determination. A high-resolution structure of the loop-rich soluble protein Sin1 could not be determined by conventional NOE-based procedures due to an insufficient number of NOE restraints. By using the 867 PRE-derived distance restraints obtained from the NOE-based structure determination procedure, a high-resolution structure of Sin1 could be successfully determined. The convergence and accuracy of the determined structure were improved by increasing the number of PRE-derived distance restraints. This study demonstrates that PRE-derived distance restraints are useful in the determination of a high-resolution structure of a soluble protein when the number of NOE constraints is insufficient

  5. Wheeled mobility device transportation safety in fixed route and demand-responsive public transit vehicles within the United States.

    Science.gov (United States)

    Frost, Karen L; van Roosmalen, Linda; Bertocci, Gina; Cross, Douglas J

    2012-01-01

    An overview of the current status of wheelchair transportation safety in fixed route and demand-responsive, non-rail, public transportation vehicles within the US is presented. A description of each mode of transportation is provided, followed by a discussion of the primary issues affecting safety, accessibility, and usability. Technologies such as lifts, ramps, securement systems, and occupant restraint systems, along with regulations and voluntary industry standards have been implemented with the intent of improving safety and accessibility for individuals who travel while seated in their wheeled mobility device (e.g., wheelchair or scooter). However, across both fixed route and demand-responsive transit systems a myriad of factors such as nonuse and misuse of safety systems, oversized wheeled mobility devices, vehicle space constraints, and inadequate vehicle operator training may place wheeled mobility device (WhMD) users at risk of injury even under non-impact driving conditions. Since WhMD-related incidents also often occur during the boarding and alighting process, the frequency of these events, along with factors associated with these events are described for each transit mode. Recommendations for improving WhMD transportation are discussed given the current state of

  6. Restraint stress impairs glucose homeostasis through altered insulin ...

    African Journals Online (AJOL)

    The study investigated the potential alteration in the level of insulin and adiponectin, as well as the expression of insulin receptors (INSR) and glucose transporter 4 GLUT-4 in chronic restraint stress rats. Sprague-Dawley rats were randomly divided into two groups: the control group and stress group in which the rats were ...

  7. Mars Science Laboratory Differential Restraint: The Devil is in the Details

    Science.gov (United States)

    Jordan, Elizabeth

    2012-01-01

    The Differential Restraint, a mechanism used on the Mars Science Laboratory (MSL) rover to maintain symmetry of the mobility system during the launch, cruise, and entry descent and landing phases of the MSL mission, completed nearly three full design cycles before a finalized successful design was achieved. This paper address the lessons learned through these design cycles, including three major design elements that can easily be overlooked during the design process, including, tolerance stack contribution to load path, the possibility of Martian dirt as a failure mode, and the effects of material properties at temperature extremes.

  8. Role of systems safety in maintaining affordable safety in the 1980's

    International Nuclear Information System (INIS)

    Hollister, H.; Trauth, C.A. Jr.

    1979-01-01

    Historically, the Department of Energy and its predecessors have used and supported the development of systems safety programs, practices, and principles, finding them by and large adequate, effective, and managerially efficient. Today, attempts are bing made to resolve increasingly complex environmental, safety, and health problems by turning to increasingly complex and detailed regulation as the primary governmental answer. It is increasingly doubtful that such an approach will provide management of these issues and problems that is either effective or efficient. Challenge is issued to those in systems safety to develop and apply systems safety principles and practices more broadly to total operational systems and not just to hardware and to environmental and health protection and not just to safety, so that the total universe of environmental, safety, and health can be managed effectively and efficiently with encouragement of innovation and creativity, using a relatively brief and concise, but adequate, regulatory base

  9. Food Intake and Success or Failure of Dietary Restraint

    NARCIS (Netherlands)

    Anschutz, D.J.; Strien, T. van; Engels, R.C.M.E.

    2006-01-01

    Objectives: Determination of success and failure of dietary restraint in relation to food intake in 510 females. Methods: Food intake as measured with the Food Frequency Questionnaire (FFQ) was assessed in low vs. high restrained eaters and overeaters, as measured with the DEBQ (Dutch Eating

  10. Systems Safety and Engineering Division

    Data.gov (United States)

    Federal Laboratory Consortium — Volpe's Systems Safety and Engineering Division conducts engineering, research, and analysis to improve transportation safety, capacity, and resiliency. We provide...

  11. Design for safety: theoretical framework of the safety aspect of BIM system to determine the safety index

    Directory of Open Access Journals (Sweden)

    Ai Lin Evelyn Teo

    2016-12-01

    Full Text Available Despite the safety improvement drive that has been implemented in the construction industry in Singapore for many years, the industry continues to report the highest number of workplace fatalities, compared to other industries. The purpose of this paper is to discuss the theoretical framework of the safety aspect of a proposed BIM System to determine a Safety Index. An online questionnaire survey was conducted to ascertain the current workplace safety and health situation in the construction industry and explore how BIM can be used to improve safety performance in the industry. A safety hazard library was developed based on the main contributors to fatal accidents in the construction industry, determined from the formal records and existing literature, and a series of discussions with representatives from the Workplace Safety and Health Institute (WSH Institute in Singapore. The results from the survey suggested that the majority of the firms have implemented the necessary policies, programmes and procedures on Workplace Safety and Health (WSH practices. However, BIM is still not widely applied or explored beyond the mandatory requirement that building plans should be submitted to the authorities for approval in BIM format. This paper presents a discussion of the safety aspect of the Intelligent Productivity and Safety System (IPASS developed in the study. IPASS is an intelligent system incorporating the buildable design concept, theory on the detection, prevention and control of hazards, and the Construction Safety Audit Scoring System (ConSASS. The system is based on the premise that safety should be considered at the design stage, and BIM can be an effective tool to facilitate the efforts to enhance safety performance. IPASS allows users to analyse and monitor key aspects of the safety performance of the project before the project starts and as the project progresses.

  12. Improved safety of the system 80+TM standard plants design through increased diversity and redundancy of safety systems

    International Nuclear Information System (INIS)

    Matzie, Regis A.; Carpentino, Frederick L.; Robertson, James E.

    1996-01-01

    Safely systems in the System 80+ TM Standard Plant are designed with more redundancy, diversity and simplicity than earlier nuclear power plant designs. These gains were accomplished by an evolutionary process that preserved the desirable and proven features in currently operating nuclear plants, while improving reliability and defense-in-depth. The System 80+ safety systems are the primary contributors to a core damage frequency that is more than 100 times lower than 1980's vintage U. S. designs, including the predecessor System 80 R standard nuclear steam supply system (NSSS) design. The System 80+ design includes significant improvements to the safety injection system, emergency feedwater system, shutdown cooling system, containment spray system, reactor coolant gas vent system, and to their vital support systems. These improvements enhance performance for traditional design basis events and significantly reduce the probability of a severe accident. The System 80+ design also incorporates safety systems to mitigate a severe accident. The added systems include the rapid depressurization system, the in-containment refueling water storage tank, the cavity flooding system. These systems fully address the U. S. Nuclear Regulatory Commission's (US NRC) severe accident policy. The System 80+ safety systems are integrated with the System 80+ Nuclear Island (NI) design. The NI general arrangement provides quadrant separation of the safety systems for protection from fire and flooding, and large equipment pull spaces and lay down areas for maintenance. This paper will describe the System 80+ safety systems advanced design features, the improved accident prevention and mitigation capabilities, and startup, operating and maintenance benefits

  13. Product Engineering Class in the Software Safety Risk Taxonomy for Building Safety-Critical Systems

    Science.gov (United States)

    Hill, Janice; Victor, Daniel

    2008-01-01

    When software safety requirements are imposed on legacy safety-critical systems, retrospective safety cases need to be formulated as part of recertifying the systems for further use and risks must be documented and managed to give confidence for reusing the systems. The SEJ Software Development Risk Taxonomy [4] focuses on general software development issues. It does not, however, cover all the safety risks. The Software Safety Risk Taxonomy [8] was developed which provides a construct for eliciting and categorizing software safety risks in a straightforward manner. In this paper, we present extended work on the taxonomy for safety that incorporates the additional issues inherent in the development and maintenance of safety-critical systems with software. An instrument called a Software Safety Risk Taxonomy Based Questionnaire (TBQ) is generated containing questions addressing each safety attribute in the Software Safety Risk Taxonomy. Software safety risks are surfaced using the new TBQ and then analyzed. In this paper we give the definitions for the specialized Product Engineering Class within the Software Safety Risk Taxonomy. At the end of the paper, we present the tool known as the 'Legacy Systems Risk Database Tool' that is used to collect and analyze the data required to show traceability to a particular safety standard

  14. The central effect of biological Amines on immunosuppressive effect of restraint stress in rat

    Directory of Open Access Journals (Sweden)

    Zeraati F

    2000-10-01

    Full Text Available The effects of some histaminergic agents were evaluated on stress- induced immunosuppression in immunized nale rats. In rat immunized with sheep red blood cells ( SRBCs. Restraint stress (RS prevented the booster-induced rise in anti-SRBC antibody titre and cell immunity response. Intracerebroventicular (I.C>V injection of histamine (150 µg/rat induced a similar effect with RS. Pretreatment with chlorpheniramine (50 µg/rat reduced the inhibitory effect of Ras on immune function. Also histamine could inhibit the effect of RS on immune function. Also histamine could inhibitory the effect of chlorpheniramine when injected simultaneously. Pretreatment with ranidine (10 µg/rat had not a significant effect. Serotonin (3 µg/rat and dopamine (0.2 µg/rat could reverse the effects of chlorpheniromine when injected with chlorpheniramine (P<0.05. Epinephrine (0.2 µg/rat had not a significant effect. The results indicate that histamine mediates the immunosuppression of restraint stress by influencing the histamine H1 receptor in the brain and this effects of histamine may be modulated by serotoninergic and dopaminergic system.

  15. Software system safety

    Science.gov (United States)

    Uber, James G.

    1988-01-01

    Software itself is not hazardous, but since software and hardware share common interfaces there is an opportunity for software to create hazards. Further, these software systems are complex, and proven methods for the design, analysis, and measurement of software safety are not yet available. Some past software failures, future NASA software trends, software engineering methods, and tools and techniques for various software safety analyses are reviewed. Recommendations to NASA are made based on this review.

  16. Probabilistic safety criteria at the safety function/system level

    International Nuclear Information System (INIS)

    1989-09-01

    A Technical Committee Meeting was held in Vienna, Austria, from 26-30 January 1987. The objectives of the meeting were: to review the national developments of PSC at the level of safety functions/systems including future trends; to analyse basic principles, assumptions, and objectives; to compare numerical values and the rationale for choosing them; to compile the experience with use of such PSC; to analyse the role of uncertainties in particular regarding procedures for showing compliance. The general objective of establishing PSC at the level of safety functions/systems is to provide a pragmatic tool to evaluate plant safety which is placing emphasis on the prevention principle. Such criteria could thus lead to a better understanding of the importance to safety of the various functions which have to be performed to ensure the safety of the plant, and the engineering means of performing these functions. They would reflect the state-of-the-art in modern PSAs and could contribute to a balance in system design. This report, prepared by the participants of the meeting, reviews the current status and future trends in the field and should assist Member States in developing their national approaches. The draft of this document was also submitted to INSAG to be considered in its work to prepare a document on safety principles for nuclear power plants. Five papers presented at the meeting are also included in this publication. A separate abstract was prepared for each of these papers. Refs, figs and tabs

  17. Reactor Safety Assessment System

    International Nuclear Information System (INIS)

    Sebo, D.E.; Bray, M.A.; King, M.A.

    1987-01-01

    The Reactor Safety Assessment System (RSAS) is an expert system under development for the United States Nuclear Regulatory Commission (USNRC). RSAS is designed for use at the USNRC Operations Center in the event of a serious incident at a licensed nuclear power plant. RSAS is a situation assessment expert system which uses plant parametric data to generate conclusions for use by the NRC Reactor Safety Team. RSAS uses multiple rule bases and plant specific setpoint files to be applicable to all licensed nuclear power plants in the United States. RSAS currently covers several generic reactor categories and multiple plants within each category

  18. Reactor safety assessment system

    International Nuclear Information System (INIS)

    Sebo, D.E.; Bray, M.A.; King, M.A.

    1987-01-01

    The Reactor Safety Assessment System (RSAS) is an expert system under development for the United States Nuclear Regulatory Commission (USNRC). RSA is designed for use at the USNRC Operations Center in the event of a serious incident at a licensed nuclear power plant. RSAS is a situation assessment expert system which uses plant parametric data to generate conclusions for use by the NRC Reactor Safety Team. RSAS uses multiple rule bases and plant specific setpoint files to be applicable to all licensed nuclear power plants in the United States. RSAS currently covers several generic reactor categories and multiple plants within each category

  19. Safety systems and safety analysis of the Qinshan phase III CANDU nuclear power plant

    International Nuclear Information System (INIS)

    Cai Jianping; Shen Sen; Barkman, N.

    1999-01-01

    The author introduces the Canadian nuclear reactor safety philosophy and the Qinshan Phase III CANDU NPP safety systems and safety analysis, which are designed and performed according to this philosophy. The concept of 'defence-in-depth' is a key element of the Canadian nuclear reactor safety philosophy. The design concepts of redundancy, diversity, separation, equipment qualification, quality assurance, and use of appropriate design codes and standards are adopted in the design. Four special safety systems as well as a set of reliable safety support systems are incorporated in the design of Qinshan phase III CANDU for accident mitigation. The assessment results for safety systems performance show that the fundamental safety criteria for public dose, and integrity of fuel, channels and the reactor building, are satisfied

  20. Utilização de assentos de segurança por crianças matriculadas em creches Utilización de asientos de seguridad por niños matriculados en guarderías Child safety restraint use among children attending day care centers

    Directory of Open Access Journals (Sweden)

    Sergio Ricardo Lopes de Oliveira

    2009-10-01

    asociados. MÉTODOS: Estudio transversal observacional, con muestreo estratificado, realizado en 15 guarderías de la ciudad de Maringá (Sur de Brasil, entre los meses de marzo y mayo de 2007. Cada guardería fue visitada en sólo un día lectivo. El resultado considerado fue la utilización de asiento de seguridad infantil por niños de hasta cuatro anos de edad. Carros (N=301 que transportaban niños menores de cuatro anos de edad fueron abordados y las informaciones fueron colectadas por medio de cuestionarios semi-estructurados. Las variables relacionadas a distribución de adultos y niños en los asientos del vehículo, situación de restricción de adultos pasajeros y niños y sexo del conductor fueron analizadas. Para análisis de los datos se aplicó la prueba exacta de Fisher, ji-cuadrado de Mantel-Haenszel y regresión logística. RESULTADOS: Entre los conductores abordados, 51,8% usaban cinturón de seguridad (60,4% de las mujeres, 44,9% de los hombres. Entre los niños, 36,1% usaban asientos de seguridad infantil, 45,4% eran transportadas sueltas, 16,0% estaban en las piernas de adultos, 2,7% usaban el cinturón de seguridad. Según la regresión logística, los factores que más influenciaron el uso de asientos de seguridad infantil fueron: edad del niño inferior a 15 meses (OR=3,76, uso de cinturón de seguridad por el conductor (OR= 2,45 y niños pertenecientes a los estratos sociocupacionales de mayor renta y escolaridad (OR=1,37. CONCLUSIONES: La utilización de asientos de seguridad infantil se mostró asociada a la edad del niño, uso de cinturón de seguridad por el conductor y estrato sociocupacional de la guardería. Frente al bajo índice de utilización, el uso de los asientos de seguridad infantil surge como desafío a la medicina preventiva en Brasil, exigiendo atención y actuación para su diseminación en la población.OBJECTIVE: To estimate the prevalence of child safety restraint use and factors associated. METHODS: Observational cross

  1. Food safety performance indicators to benchmark food safety output of food safety management systems.

    Science.gov (United States)

    Jacxsens, L; Uyttendaele, M; Devlieghere, F; Rovira, J; Gomez, S Oses; Luning, P A

    2010-07-31

    There is a need to measure the food safety performance in the agri-food chain without performing actual microbiological analysis. A food safety performance diagnosis, based on seven indicators and corresponding assessment grids have been developed and validated in nine European food businesses. Validation was conducted on the basis of an extensive microbiological assessment scheme (MAS). The assumption behind the food safety performance diagnosis is that food businesses which evaluate the performance of their food safety management system in a more structured way and according to very strict and specific criteria will have a better insight in their actual microbiological food safety performance, because food safety problems will be more systematically detected. The diagnosis can be a useful tool to have a first indication about the microbiological performance of a food safety management system present in a food business. Moreover, the diagnosis can be used in quantitative studies to get insight in the effect of interventions on sector or governmental level. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Comparison of chemical restraint techniques in ostrich (Struthio camelus

    Directory of Open Access Journals (Sweden)

    R Ciboto

    2006-06-01

    Full Text Available Chemical restraint in ostriches is usually required for short-time interventions. Thus, this study established and evaluated intravenous anesthetics formulated from commonly used drugs in order to accomplish total restraint on this species and allow painful procedures to be performed. Thirty male and female ostriches weighing from 40 to 90 kg were randomly distributed into five groups. Animals in Groups I, II and III were given acepromazine (0.25 mg/kg i.m. and those in Groups IV and V were given xylazine (1.0 mg/kg i.m.. The following drugs were administered intravenously 15 to 20 min later: Group I - propofol (4.0 mg/kg, Groups II and IV - ketamine (5.0 mg/kg and diazepam (0.25 mg/kg, Groups III and V - tiletamine-zolazepam (3.0 mg/kg. All protocols have produced satisfactory results regarding total containment, muscular relaxation and maintenance of the evaluated parameters within a normal range.

  3. Safety and interlock system for Tristan

    International Nuclear Information System (INIS)

    Takeda, S.; Kudo, K.; Katoh, T.; Akiyama, A.

    1987-01-01

    This report describes alarm and interlock system of TRISTAN, concentrating on personnel safety. The basis of TRISTAN machine-control system (TMS) is an N-to-N computer network and KEK NODAL which offers high software productivity. TMC achieves high flexibility of operation both for normal operation and for the fast commissioning. However, to assure the safety of personnel and the TRISTAN machine operation, the safety system has to continue functioning during TMC failure as well. A distributed safety and interlock system (DSIS) is used for diversification of risks in TRISTAN system. DSIS is functionally subdivided along local system lines and has a hierarchical structure of 12 programmable sequence controllers (PSCs). Optical fiber links connect the PSCs at subsystem level and a PSC at the supervisory level of TRISTAN central control room (TCCR). The subsystem PSCs provide the interlock functions between their local devices. The local PSCs interact with the central system through a limited number of summarized signals. The central PSC provides the interlock functions between the subsystems and interacts with an operator's panel. Personnel safety is based on a system of electrical interlock keys, emergency push-buttons around the tunnel, at the entrance gates or in the control room

  4. Did Child Restraint Laws Globally Converge? Examining 40 Years of Policy Diffusion.

    Science.gov (United States)

    Nazif-Muñoz, José Ignacio

    2015-01-01

    The objective of the current study is to determine what factors have been associated with the global adoption of mandatory child restraint laws (ChRLs) since 1975. In order to determine what factors explained the global adoption of mandatory ChRLs, Weibull models were analyzed. To carry out this analysis, 170 countries were considered and the time risk corresponded to 5,146 observations for the period 1957-2013. The dependent variable was first time to adopt a ChRL. Independent variables representing global factors were the World Health Organization (WHO) and World Bank's (WB) road safety global campaign; the Geneva Convention on Road Traffic; and the United Nation's (UN) 1958 Vehicle Agreement. Independent variables representing regional factors were the creation of the European Transport Safety Council and being a Commonwealth country. Independent variables representing national factors were population; gross domestic product (GDP) per capita; political violence; existence of road safety nongovernmental organizations (NGOs); and existence of road safety agencies. Urbanization served as a control variable. To examine regional dynamics, Weibull models for Africa, Asia, Europe, North America, Latin America, the Caribbean, and the Commonwealth were also carried out. Empirical estimates from full Weibull models suggest that 2 global factors and 2 national factors are significantly associated with the adoption of this measure. The global factors explaining adoption are the WHO and WB's road safety global campaign implemented after 2004 (P policy was global. Regional analysis showed that the UN's Convention on Road Traffic was significant in Asia, the creation of the European Transport Safety Council was significant in Europe and North America, and the global campaign was in Africa. In Commonwealth and European and North American countries, the existence of road safety agencies was also positively associated with ChRL adoption. Results of the world models suggest that

  5. Safety-critical Java for embedded systems

    DEFF Research Database (Denmark)

    Schoeberl, Martin; Dalsgaard, Andreas Engelbredt; Hansen, René Rydhof

    2016-01-01

    This paper presents the motivation for and outcomes of an engineering research project on certifiable Javafor embedded systems. The project supports the upcoming standard for safety-critical Java, which defines asubset of Java and libraries aiming for development of high criticality systems....... The outcome of this projectinclude prototype safety-critical Java implementations, a time-predictable Java processor, analysis tools formemory safety, and example applications to explore the usability of safety-critical Java for this applicationarea. The text summarizes developments and key contributions...

  6. Physical restraint and the protection of the human rights of immigration detainees in hospitals.

    Science.gov (United States)

    Pickles, Hilary; Norton, Emma; Ginn, Emma; Schleicher, Theresa

    2015-08-01

    Immigration detainees, like prisoners, are entitled to the same standard of healthcare as non-detained patients. When hospital attendance or admission is required, the priority for custodial staff (who for purposes of this article we refer to as 'escorts') is to prevent absconding. For that reason, they may wish to use physical restraints, such as handcuffs, and remain with the detainee at all times. This can be degrading for the patient and breach their human rights. Clinicians have professional obligations to all their patients and must object to any restraint methods that risk damaging the patient's right to confidentiality, treatment, health or the therapeutic relationship itself. The starting presumption is that restraints ought not to be used during treatment and only in the most exceptional cases ought escorts to be present during clinical examination or treatment. © Royal College of Physicians 2015. All rights reserved.

  7. Alcohol, Appetite and Loss of Restraint.

    Science.gov (United States)

    Caton, Samantha J; Nolan, Laurence J; Hetherington, Marion M

    2015-03-01

    Alcoholic beverages have long been associated with feasts, celebration and marking special events. Today, it is commonplace to consume alcoholic beverages before, with and/or after a meal. Alcohol provides additional pleasure to the meal and enhances appetite. However, consuming an alcoholic beverage with or before a meal is associated with poor short-term energy compensation; energy from alcohol is additive to total energy intake with the added property of stimulating further eating. Limiting alcohol intake is an obvious means to reduce total energy intake for those who wish to lose weight. However, dieters and restrained eaters drink more and report greater binge drinking than unrestrained eaters despite employing cognitive strategies to reduce their intake. Increased intake may be attributable to greater attentional bias to alcohol related cues as well as to food cues, since these are more salient to those limiting intake. Alcohol increases energy intake in dieters, in part due to abandonment of restraint (disinhibition) and consumption of forbidden items including alcohol exacerbates attempts to resist temptation. Paradoxically, links between binge drinking or increased drinking frequency to overweight and obesity may be mediated by dietary restraint. Efforts to limit food and alcohol intake for weight control appear to be unsuccessful and have the net effect of promoting overconsumption. The potential role of restrained eating in the association between alcohol, appetite and obesity has been overlooked by much of the current research and further investigation of this is therefore warranted.

  8. Imidazoline2 (I2) receptor- and alpha2-adrenoceptor-mediated modulation of hypothalamic-pituitary-adrenal axis activity in control and acute restraint stressed rats.

    Science.gov (United States)

    Finn, David P; Hudson, Alan L; Kinoshita, Hiroshi; Coventry, Toni L; Jessop, David S; Nutt, David J; Harbuz, Michael S

    2004-03-01

    Central noradrenaline regulates the activity of the hypothalamic-pituitary-adrenal (HPA) axis and the neuroendocrine response to stress. alpha2-adrenoceptors and imidazoline2 (I2) receptors modulate the activity of the central noradrenergic system. The present set of experiments investigated the role of alpha2-adrenoceptors and I2 receptors in the regulation of HPA axis activity under basal conditions and during exposure to the acute psychological stress of restraint. Three separate experiments were carried out in which rats were given an i.p. injection of either saline vehicle, the combined alpha2-adrenoceptor antagonist and I2 receptor ligand idazoxan (10 mg/kg), the selective I2 receptor ligand BU224 (2.5 or 10 mg/kg) or the selective alpha2-adrenoceptor antagonist RX821002 (2.5 mg/kg) with or without restraint stress. Drugs were administered immediately prior to restraint of 60 min duration. Blood was sampled pre-injection, 30, 60 and 240 min post-injection and plasma corticosterone was measured by radioimmunoassay. In experiment 1, idazoxan increased plasma corticosterone levels in naive animals and potentiated the corticosterone response to acute restraint stress. In experiment 2, BU224 administration increased plasma corticosterone levels in a dose-related manner in naive rats. The results of experiment 3 indicated that RX821002 also elevated plasma corticosterone levels in naive rats, however, only BU224 potentiated the corticosterone response to restraint stress. These studies suggest that both alpha2-adrenoceptors and I2 receptors play a role in modulating basal HPA axis activity and that I2 receptors may play a more important role than alpha2-adrenoceptors in modulating the HPA axis response to the acute psychological stress of restraint.

  9. A study of software safety analysis system for safety-critical software

    International Nuclear Information System (INIS)

    Chang, H. S.; Shin, H. K.; Chang, Y. W.; Jung, J. C.; Kim, J. H.; Han, H. H.; Son, H. S.

    2004-01-01

    The core factors and requirements for the safety-critical software traced and the methodology adopted in each stage of software life cycle are presented. In concept phase, Failure Modes and Effects Analysis (FMEA) for the system has been performed. The feasibility evaluation of selected safety parameter was performed and Preliminary Hazards Analysis list was prepared using HAZOP(Hazard and Operability) technique. And the check list for management control has been produced via walk-through technique. Based on the evaluation of the check list, activities to be performed in requirement phase have been determined. In the design phase, hazard analysis has been performed to check the safety capability of the system with regard to safety software algorithm using Fault Tree Analysis (FTA). In the test phase, the test items based on FMEA have been checked for fitness guided by an accident scenario. The pressurizer low pressure trip algorithm has been selected to apply FTA method to software safety analysis as a sample. By applying CASE tool, the requirements traceability of safety critical system has been enhanced during all of software life cycle phases

  10. The Airbag as a Supplement to Standard Restraint Systems in the AH-1 and AH-64 Attack Helicopters and Its Role in Reducing Head Strikes of the Copilot/ Gunner. Volume 1

    Science.gov (United States)

    1991-01-01

    shelf and locally available automotive airbag system was selected for the tests. The system was a driver’s side airbag designed by Honda Motor Company...allowance for hardware redesign or modifi- cation. Despite these limitations, the study succeeded in demonstrating a problem exists and a supplemental airbag ...JSAARL Repqrt No. 91-8 AD-A233 349 Volume’ I(3 The Airbag as a Supplement to Standard Restraint Systems in the AH-1 and AH-64 Attack Helicopters and

  11. Safety assessment for Generation IV nuclear systems

    International Nuclear Information System (INIS)

    Leahy, T.J.

    2012-01-01

    The Generation IV International Forum (GIF) Risk and Safety Working Group (RSWG) was created to develop an effective approach for the safety of Generation IV advanced nuclear energy systems. Recent RSWG work has focused on the definition of an integrated safety assessment methodology (ISAM) for evaluating the safety of Generation IV systems. ISAM is an integrated 'tool-kit' consisting of 5 analytical techniques that are available and matched to appropriate stages of Generation IV system concept development: 1) qualitative safety features review - QSR, 2) phenomena identification and ranking table - PIRT, 3) objective provision tree - OPT, 4) deterministic and phenomenological analyses - DPA, and 5) probabilistic safety analysis - PSA. The integrated methodology is intended to yield safety-related insights that help actively drive the evolving design throughout the technology development cycle, potentially resulting in enhanced safety, reduced costs, and shortened development time

  12. Technical nuclear safety in France. Control by the governmental authority

    International Nuclear Information System (INIS)

    1991-12-01

    In publishing this latest edition, we have endeavoured to provide the reader with the information necessary to obtain a full understanding of the regulatory system applied to ensure technical nuclear safety in France. As the reader will discover in the following pages, technical nuclear safety is a matter which must be settled in advance of the actual operation of civil nuclear installations; the primary requirement is to mobilize those involved to anticipate and prevent. The fundamental options on which the French system is based, the relationship between the operator and the safety authority must be clearly stated: independence of judgement and decision, complementarity of responsibilities. It is for the governmental authorities to determine the technical nuclear safety objectives, which are becoming more and more consistent if not unified throughout the world. It is for the operator to propose technical provisions in order to achieve these objectives. It is for the governmental authorities to verify, by technical safety analyses, the adequacy of the provisions in terms of the defined objectives. It is for the operator to properly implement these approved provisions. And, finally, it is for the governmental authorities to verify, by sampling, the quality of their implementation and to make from them the necessary regulatory inferences. This sequence of events requires permanent frank in-depth dialogue. The effectiveness of the regulatory action must therefore reside not in close technical restraint but in the interactions between responsible partners

  13. Technical nuclear safety in France. Control by the governmental authority

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-12-15

    In publishing this latest edition, we have endeavoured to provide the reader with the information necessary to obtain a full understanding of the regulatory system applied to ensure technical nuclear safety in France. As the reader will discover in the following pages, technical nuclear safety is a matter which must be settled in advance of the actual operation of civil nuclear installations; the primary requirement is to mobilize those involved to anticipate and prevent. The fundamental options on which the French system is based, the relationship between the operator and the safety authority must be clearly stated: independence of judgement and decision, complementarity of responsibilities. It is for the governmental authorities to determine the technical nuclear safety objectives, which are becoming more and more consistent if not unified throughout the world. It is for the operator to propose technical provisions in order to achieve these objectives. It is for the governmental authorities to verify, by technical safety analyses, the adequacy of the provisions in terms of the defined objectives. It is for the operator to properly implement these approved provisions. And, finally, it is for the governmental authorities to verify, by sampling, the quality of their implementation and to make from them the necessary regulatory inferences. This sequence of events requires permanent frank in-depth dialogue. The effectiveness of the regulatory action must therefore reside not in close technical restraint but in the interactions between responsible partners.

  14. [Effects of a training of power and balance on the use of mechanical restraint among in-patients with dementia].

    Science.gov (United States)

    Steinert, Tilman; Bohnet, Ulrich; Flammer, Erich; Lüchtenberg, Dietmar; Eisele, Frank

    2009-09-01

    Patients with dementia are most frequently affected by mechanical restraint in psychiatric hospitals, most frequently due to falls. There is evidence for beneficial effects of a training of power and balance on the frequency of falls in residential homes. An adapted training of power and balance was developed by specialists of training in sports. In 2007, 159 patients with dementia were trained. The frequency and duration of mechanical restraint was compared with a control group of a different hospital (n = 217) and the patients treated in the year before (n = 164). The percentage of patients with mechanical restraint and the mean duration of restraint per admission were significantly lower than in the control group. However, only a non-significant reduction could be achieved in comparison with the patients treated in the year before without an increase of falls. A considerable reduction of the use of mechanical restraint in patients with dementia is feasible. An unequivocal association with the training could not be confirmed due to other influencing factors.

  15. The concurrent validity of a classification of dieters with low versus high susceptibility toward failure of restraint

    NARCIS (Netherlands)

    van Strien, T

    1997-01-01

    It has been experimentally shown that the population of high restrained eaters consists of two subpopulations, i.e., those with a low and those with a high susceptibility toward failure of restraint. Only those who combined high restraint with high scores on the disinhibition scale of the TFEQ

  16. Dietary restraint and self-discrepancy in male university students.

    Science.gov (United States)

    Orellana, Ligia; Grunert, Klaus G; Sepúlveda, José; Lobos, Germán; Denegri, Marianela; Miranda, Horacio; Adasme-Berríos, Cristian; Mora, Marcos; Etchebarne, Soledad; Salinas-Oñate, Natalia; Schnettler, Berta

    2016-04-01

    Self-discrepancy describes the distance between an ideal and the actual self. Research suggests that self-discrepancy and dietary restraint are related, causing a significant impact on the person's well-being. However, this relationship has been mostly reported in female and mixed populations. In order to further explore dietary behaviors and their relations to self-discrepancy and well-being-related variables in men, a survey was applied to a non-probabilistic sample of 119 male students from five Chilean state universities (mean age=21.8, SD=2.75). The questionnaire included the Revised Restraint Scale (RRS) with the subscales weight fluctuations (WF) and diet concern (DC), the Satisfaction with Life Scale (SWLS), the Satisfaction with Food-Related Life Scale (SWFL), the Nutrition Interest Scale (NIS), and the Self-discrepancy Index (SDI). Questions were asked about socio-demographic characteristics, eating and drinking habits, and approximate weight and height. A cluster analysis applied to the Z-scores of the RRS classified the following typologies: Group 1 (22.7%), men concerned about weight fluctuations; Group 2 (37.0%), men concerned about diet and weight fluctuations; Group 3 (40.3%), unconcerned about diet and weight fluctuations. The typologies differed in their SDI score, restriction on pastry consumption and reported body mass index (BMI). Students with higher DC and WF scores had a higher BMI, and tended to report high self-discrepancy not only on a physical level, but also on social, emotional, economic and personal levels. This study contributes to the literature on subjective well-being, dietary restraint and self-discrepancy in men from non-clinical samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. OBTAINING FOOD SAFETY BY APPLYING HACCP SYSTEM

    Directory of Open Access Journals (Sweden)

    ION CRIVEANU

    2012-01-01

    Full Text Available In order to increase the confidence of the trading partners and consumers in the products which are sold on the market, enterprises producing food are required to implement the food safety system HACCP,a particularly useful system because the manufacturer is not able to fully control finished products . SR EN ISO 22000:2005 establishes requirements for a food safety management system where an organization in the food chain needs to proove its ability to control food safety hazards in order to ensure that food is safe at the time of human consumption. This paper presents the main steps which ensure food safety using the HACCP system, and SR EN ISO 20000:2005 requirements for food safety.

  18. Emotional eating and routine restraint scores are associated with activity in brain regions involved in urge and self-control.

    Science.gov (United States)

    Wood, Samantha M W; Schembre, Susan M; He, Qinghua; Engelmann, Jeffrey M; Ames, Susan L; Bechara, Antoine

    2016-10-15

    Researchers have proposed a variety of behavioral traits that may lead to weight gain and obesity; however, little is known about the neurocognitive mechanisms underlying these weight-related eating behaviors. In this study, we measured activation of reward circuitry during a task requiring response and inhibition to food stimuli. We assessed participants' emotional eating, external eating, and two subscales of dietary restraint-routine restraint and compensatory restraint-using the Weight-Related Eating Questionnaire. For routine restraint, we found positive associations with activation in the insula, dorsolateral prefrontal cortex, anterior cingulate cortex, orbitofrontal cortex and ventromedial prefrontal cortex in response to high-calorie versus low-calorie foods. For emotional eating, we found positive associations with insula and dorsolateral prefrontal cortex activation in response to high-calorie versus low-calorie foods. We also found positive associations between emotional eating and dorsolateral prefrontal cortex activation in response to approach versus inhibition towards high-calorie foods. Thus, our results demonstrate an increase in activation across brain regions related to self-control and urges in response to high-calorie food associated with both emotional eating and routine restraint. Overall, these results support the construct validity of both emotional eating and routine restraint and provide preliminary evidence that these subscales have similar neural correlates. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Industrial Personal Computer based Display for Nuclear Safety System

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min

    2014-01-01

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view

  20. Industrial Personal Computer based Display for Nuclear Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyeon; Kim, Aram; Jo, Jung Hee; Kim, Ki Beom; Cheon, Sung Hyun; Cho, Joo Hyun; Sohn, Se Do; Baek, Seung Min [KEPCO, Youngin (Korea, Republic of)

    2014-08-15

    The safety display of nuclear system has been classified as important to safety (SIL:Safety Integrity Level 3). These days the regulatory agencies are imposing more strict safety requirements for digital safety display system. To satisfy these requirements, it is necessary to develop a safety-critical (SIL 4) grade safety display system. This paper proposes industrial personal computer based safety display system with safety grade operating system and safety grade display methods. The description consists of three parts, the background, the safety requirements and the proposed safety display system design. The hardware platform is designed using commercially available off-the-shelf processor board with back plane bus. The operating system is customized for nuclear safety display application. The display unit is designed adopting two improvement features, i.e., one is to provide two separate processors for main computer and display device using serial communication, and the other is to use Digital Visual Interface between main computer and display device. In this case the main computer uses minimized graphic functions for safety display. The display design is at the conceptual phase, and there are several open areas to be concreted for a solid system. The main purpose of this paper is to describe and suggest a methodology to develop a safety-critical display system and the descriptions are focused on the safety requirement point of view.

  1. The LHC personnel safety system

    International Nuclear Information System (INIS)

    Ninin, P.; Valentini, F.; Ladzinski, T.

    2011-01-01

    Large particle physics installations such as the CERN Large Hadron Collider require specific Personnel Safety Systems (PSS) to protect the personnel against the radiological and industrial hazards. In order to fulfill the French regulation in matter of nuclear installations, the principles of IEC 61508 and IEC 61513 standard are used as a methodology framework to evaluate the criticality of the installation, to design and to implement the PSS.The LHC PSS deals with the implementation of all physical barriers, access controls and interlock devices around the 27 km of underground tunnel, service zones and experimental caverns of the LHC. The system shall guarantee the absence of personnel in the LHC controlled areas during the machine operations and, on the other hand, ensure the automatic accelerator shutdown in case of any safety condition violation, such as an intrusion during beam circulation. The LHC PSS has been conceived as two separate and independent systems: the LHC Access Control System (LACS) and the LHC Access Safety System (LASS). The LACS, using off the shelf technologies, realizes all physical barriers and regulates all accesses to the underground areas by identifying users and checking their authorizations.The LASS has been designed according to the principles of the IEC 61508 and 61513 standards, starting from a risk analysis conducted on the LHC facility equipped with a standard access control system. It consists in a set of safety functions realized by a dedicated fail-safe and redundant hardware guaranteed to be of SIL3 class. The integration of various technologies combining electronics, sensors, video and operational procedures adopted to establish an efficient personnel safety system for the CERN LHC accelerator is presented in this paper. (authors)

  2. Cost benefit analysis of reactor safety systems

    International Nuclear Information System (INIS)

    Maurer, H.A.

    1984-01-01

    Cost/benefit analysis of reactor safety systems is a possibility appropriate to deal with reactor safety. The Commission of the European Communities supported a study on the cost-benefit or cost effectiveness of safety systems installed in modern PWR nuclear power plants. The following systems and their cooperation in emergency cases were in particular investigated in this study: the containment system (double containment), the leakage exhaust and control system, the annulus release exhaust system and the containment spray system. The benefit of a safety system is defined according to its contribution to the reduction of the radiological consequences for the environment after a LOCA. The analysis is so far performed in two different steps: the emergency core cooling system is considered to function properly, failure of the emergency core cooling system is assumed (with the possible consequence of core melt-down) and the results may demonstrate the evidence that striving for cost-effectiveness can produce a safer end result than the philosophy of safety at any cost. (orig.)

  3. Control Method of Single-phase Inverter Based Grounding System in Distribution Networks

    DEFF Research Database (Denmark)

    Wang, Wen; Yan, L.; Zeng, X.

    2016-01-01

    of neutral-to-ground voltage is critical for the safety of distribution networks. An active grounding system based on single-phase inverter is proposed to achieve this objective. Relationship between output current of the system and neutral-to-ground voltage is derived to explain the principle of neutral......The asymmetry of the inherent distributed capacitances causes the rise of neutral-to-ground voltage in ungrounded system or high resistance grounded system. Overvoltage may occur in resonant grounded system if Petersen coil is resonant with the distributed capacitances. Thus, the restraint...

  4. Safer Systems: A NextGen Aviation Safety Strategic Goal

    Science.gov (United States)

    Darr, Stephen T.; Ricks, Wendell R.; Lemos, Katherine A.

    2008-01-01

    The Joint Planning and Development Office (JPDO), is charged by Congress with developing the concepts and plans for the Next Generation Air Transportation System (NextGen). The National Aviation Safety Strategic Plan (NASSP), developed by the Safety Working Group of the JPDO, focuses on establishing the goals, objectives, and strategies needed to realize the safety objectives of the NextGen Integrated Plan. The three goal areas of the NASSP are Safer Practices, Safer Systems, and Safer Worldwide. Safer Practices emphasizes an integrated, systematic approach to safety risk management through implementation of formalized Safety Management Systems (SMS) that incorporate safety data analysis processes, and the enhancement of methods for ensuring safety is an inherent characteristic of NextGen. Safer Systems emphasizes implementation of safety-enhancing technologies, which will improve safety for human-centered interfaces and enhance the safety of airborne and ground-based systems. Safer Worldwide encourages coordinating the adoption of the safer practices and safer systems technologies, policies and procedures worldwide, such that the maximum level of safety is achieved across air transportation system boundaries. This paper introduces the NASSP and its development, and focuses on the Safer Systems elements of the NASSP, which incorporates three objectives for NextGen systems: 1) provide risk reducing system interfaces, 2) provide safety enhancements for airborne systems, and 3) provide safety enhancements for ground-based systems. The goal of this paper is to expose avionics and air traffic management system developers to NASSP objectives and Safer Systems strategies.

  5. How the architect-engineer manages design objectives and restraints for optimizing sodium cooled reactors

    International Nuclear Information System (INIS)

    Roe, K.A.; Roe, K.K.

    1978-01-01

    The design objectives of low capital and operating costs and high reliability are best attained by carefully defining criteria early in the development stage. Throughout the design development, unusual attention to constructibility, reliability and availability requirements, and the early resolution of licensing issues by designated engineering specialists are some of the approaches used to minimize design restraints. Effective management of these design objectives and restraints can assure that, on balance, LMFBR costs can be improved, reliability increased, and maintenance can be effective. (author)

  6. Development of digital safety system logic and control

    International Nuclear Information System (INIS)

    Nishikawa, H.; Sakamoto, H.

    1995-01-01

    Advanced-BWR (ABWR) uses total digital control and instrumentation (C and I) system. In particular, ABWR adopts a newly developed safety system using advanced digital technology. In the presentation the digital safety system design, manufacturing and factory validation test method are shortly overviewed. The digital safety system consists of micro-processor based digital controllers, data and information transmission by optical fibers and human-machine interface using color flat displays. This new developed safety system meet the nuclear safety requirements such as high reliability, independence of divisions, operability and maintainability. (2 refs., 4 figs., 1 tab.)

  7. Safety features of subcritical fluid fueled systems

    International Nuclear Information System (INIS)

    Bell, C.R.

    1995-01-01

    Accelerator-driven transmutation technology has been under study at Los Alamos for several years for application to nuclear waste treatment, tritium production, energy generation, and recently, to the disposition of excess weapons plutonium. Studies and evaluations performed to date at Los Alamos have led to a current focus on a fluid-fuel, fission system operating in a neutron source-supported subcritical mode, using molten salt reactor technology and accelerator-driven proton-neutron spallation. In this paper, the safety features and characteristics of such systems are explored from the perspective of the fundamental nuclear safety objectives that any reactor-type system should address. This exploration is qualitative in nature and uses current vintage solid-fueled reactors as a baseline for comparison. Based on the safety perspectives presented, such systems should be capable of meeting the fundamental nuclear safety objectives. In addition, they should be able to provide the safety robustness desired for advanced reactors. However, the manner in which safety objectives and robustness are achieved is very different from that associated with conventional reactors. Also, there are a number of safety design and operational challenges that will have to be addressed for the safety potential of such systems to be credible

  8. Safety features of subcritical fluid fueled systems

    International Nuclear Information System (INIS)

    Bell, C.R.

    1994-01-01

    Accelerator-driven transmutation technology has been under study at Los Alamos for several years for application to nuclear waste treatment, tritium production, energy generation, and recently, to the disposition of excess weapons plutonium. Studies and evaluations performed to date at Los Alamos have led to a current focus on a fluid-fuel, fission system operating in a neutron source-supported subcritical mode, using molten salt reactor technology and accelerator-driven proton-neutron spallation. In this paper, the safety features and characteristics of such systems are explored from the perspective of the fundamental nuclear safety objectives that any reactor-type system should address. This exploration is qualitative in nature and uses current vintage solid-fueled reactors as a baseline for comparison. Based on the safety perspectives presented, such systems should be capable of meeting the fundamental nuclear safety objectives. In addition, they should be able to provide the safety robustness desired for advanced reactors. However, the manner in which safety objectives and robustness are achieved in very different from that associated with conventional reactors. Also, there are a number of safety design and operational challenges that will have to be addressed for the safety potential of such systems to be credible

  9. Safety features of subcritical fluid fueled systems

    Energy Technology Data Exchange (ETDEWEB)

    Bell, C.R. [Los Alamos National Laboratory, NM (United States)

    1995-10-01

    Accelerator-driven transmutation technology has been under study at Los Alamos for several years for application to nuclear waste treatment, tritium production, energy generation, and recently, to the disposition of excess weapons plutonium. Studies and evaluations performed to date at Los Alamos have led to a current focus on a fluid-fuel, fission system operating in a neutron source-supported subcritical mode, using molten salt reactor technology and accelerator-driven proton-neutron spallation. In this paper, the safety features and characteristics of such systems are explored from the perspective of the fundamental nuclear safety objectives that any reactor-type system should address. This exploration is qualitative in nature and uses current vintage solid-fueled reactors as a baseline for comparison. Based on the safety perspectives presented, such systems should be capable of meeting the fundamental nuclear safety objectives. In addition, they should be able to provide the safety robustness desired for advanced reactors. However, the manner in which safety objectives and robustness are achieved is very different from that associated with conventional reactors. Also, there are a number of safety design and operational challenges that will have to be addressed for the safety potential of such systems to be credible.

  10. 77 FR 11120 - Patient Safety Organizations: Voluntary Relinquishment From UAB Health System Patient Safety...

    Science.gov (United States)

    2012-02-24

    ... Organizations: Voluntary Relinquishment From UAB Health System Patient Safety Organization AGENCY: Agency for... notification of voluntary relinquishment from the UAB Health System Patient Safety Organization of its status as a Patient Safety Organization (PSO). The Patient Safety and Quality Improvement Act of 2005...

  11. Repeated restraint stress lowers the threshold for response to third ventricle CRF administration.

    Science.gov (United States)

    Harris, Ruth B S

    2017-03-01

    Rats and mice exposed to repeated stress or a single severe stress exhibit a sustained increase in energetic, endocrine, and behavioral response to subsequent novel mild stress. This study tested whether the hyper-responsiveness was due to a lowered threshold of response to corticotropin releasing factor (CRF) or an exaggerated response to a standard dose of CRF. Male Sprague-Dawley rats were subjected to 3h of restraint on each of 3 consecutive days (RRS) or were non-restrained controls. RRS caused a temporary hypophagia but a sustained reduction in body weight. Eight days after the end of restraint, rats received increasing third ventricle doses of CRF (0-3.0μg). The lowest dose of CRF (0.25μg) increased corticosterone release in RRS, but not control rats. Higher doses caused the same stimulation of corticosterone in the two groups of rats. Fifteen days after the end of restraint, rats were food deprived during the light period and received increasing third ventricle doses of CRF at the start of the dark period. The lowest dose of CRF inhibited food intake during the first hour following infusion in RRS, but not control rats. All other doses of CRF inhibited food intake to the same degree in both RRS and control rats. The lowered threshold of response to central CRF is consistent with the chronic hyper-responsiveness to CRF and mild stress in RRS rats during the post-restraint period. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. "A Very Fine Line": Parents' Experiences of Using Restraint with Their Adult Son/Daughter with Intellectual Disabilities

    Science.gov (United States)

    Elford, Helen; Beail, Nigel; Clarke, Zara

    2010-01-01

    Background: Restraint is sometimes used on people with intellectual disabilities who display challenging behaviours, and may be justifiable as a last resort to prevent harm. A substantial proportion of such people are cared for within the family home. The aim of this paper is to explore parents' experiences of using restraint with their…

  13. Safety Justification and Safety Case for Safety-critical Software in Digital Reactor Protection System

    International Nuclear Information System (INIS)

    Kwon, Kee-Choon; Lee, Jang-Soo; Jee, Eunkyoung

    2016-01-01

    Nuclear safety-critical software is under strict regulatory requirements and these regulatory requirements are essential for ensuring the safety of nuclear power plants. The verification & validation (V and V) and hazard analysis of the safety-critical software are required to follow regulatory requirements through the entire software life cycle. In order to obtain a license from the regulatory body through the development and validation of safety-critical software, it is essential to meet the standards which are required by the regulatory body throughout the software development process. Generally, large amounts of documents, which demonstrate safety justification including standard compliance, V and V, hazard analysis, and vulnerability assessment activities, are submitted to the regulatory body during the licensing process. It is not easy to accurately read and evaluate the whole documentation for the development activities, implementation technology, and validation activities. The safety case methodology has been kwon a promising approach to evaluate the level and depth of the development and validation results. A safety case is a structured argument, supported by a body of evidence that provides a compelling, comprehensible, and valid case that a system is safe for a given application in a given operating environment. It is suggested to evaluate the level and depth of the results of development and validation by applying safety case methodology to achieve software safety demonstration. A lot of documents provided as evidence are connected to claim that corresponds to the topic for safety demonstration. We demonstrated a case study in which more systematic safety demonstration for the target system software is performed via safety case construction than simply listing the documents

  14. Safety Justification and Safety Case for Safety-critical Software in Digital Reactor Protection System

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee-Choon; Lee, Jang-Soo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Jee, Eunkyoung [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    Nuclear safety-critical software is under strict regulatory requirements and these regulatory requirements are essential for ensuring the safety of nuclear power plants. The verification & validation (V and V) and hazard analysis of the safety-critical software are required to follow regulatory requirements through the entire software life cycle. In order to obtain a license from the regulatory body through the development and validation of safety-critical software, it is essential to meet the standards which are required by the regulatory body throughout the software development process. Generally, large amounts of documents, which demonstrate safety justification including standard compliance, V and V, hazard analysis, and vulnerability assessment activities, are submitted to the regulatory body during the licensing process. It is not easy to accurately read and evaluate the whole documentation for the development activities, implementation technology, and validation activities. The safety case methodology has been kwon a promising approach to evaluate the level and depth of the development and validation results. A safety case is a structured argument, supported by a body of evidence that provides a compelling, comprehensible, and valid case that a system is safe for a given application in a given operating environment. It is suggested to evaluate the level and depth of the results of development and validation by applying safety case methodology to achieve software safety demonstration. A lot of documents provided as evidence are connected to claim that corresponds to the topic for safety demonstration. We demonstrated a case study in which more systematic safety demonstration for the target system software is performed via safety case construction than simply listing the documents.

  15. Pipeline dynamics subject to restraints with clearance

    International Nuclear Information System (INIS)

    Loula, A.F.D.; Guerreiro, J.N.C.

    1980-12-01

    The principle of virtual works at its incremental form, is utilized for the formulation of flat pipeline vibration problems, of elastic-plastic behavior, submitted to restraints with clearance (also with elastic-plastic behavior) and with viscous damping. The possibility of uniform movement of the support, that simulates the seismic action is also considered. The finite element method and an integration time algorithm, are utilized for the problem resolution. Some examples ilustrate the application of the development program. (Author) [pt

  16. INTEGRATED SAFETY MANAGEMENT SYSTEM IN AIR TRAFFIC SERVICES

    Directory of Open Access Journals (Sweden)

    Volodymyr Kharchenko

    2014-06-01

    Full Text Available The article deals with the analysis of the researches conducted in the field of safety management systems.Safety management system framework, methods and tools for safety analysis in Air Traffic Control have been reviewed.Principles of development of Integrated safety management system in Air Traffic Services have been proposed.

  17. Analysis and design on airport safety information management system

    Directory of Open Access Journals (Sweden)

    Yan Lin

    2017-01-01

    Full Text Available Airport safety information management system is the foundation of implementing safety operation, risk control, safety performance monitor, and safety management decision for the airport. The paper puts forward the architecture of airport safety information management system based on B/S model, focuses on safety information processing flow, designs the functional modules and proposes the supporting conditions for system operation. The system construction is helpful to perfecting the long effect mechanism driven by safety information, continually increasing airport safety management level and control proficiency.

  18. System theory and safety models in Swedish, UK, Dutch and Australian road safety strategies.

    Science.gov (United States)

    Hughes, B P; Anund, A; Falkmer, T

    2015-01-01

    Road safety strategies represent interventions on a complex social technical system level. An understanding of a theoretical basis and description is required for strategies to be structured and developed. Road safety strategies are described as systems, but have not been related to the theory, principles and basis by which systems have been developed and analysed. Recently, road safety strategies, which have been employed for many years in different countries, have moved to a 'vision zero', or 'safe system' style. The aim of this study was to analyse the successful Swedish, United Kingdom and Dutch road safety strategies against the older, and newer, Australian road safety strategies, with respect to their foundations in system theory and safety models. Analysis of the strategies against these foundations could indicate potential improvements. The content of four modern cases of road safety strategy was compared against each other, reviewed against scientific systems theory and reviewed against types of safety model. The strategies contained substantial similarities, but were different in terms of fundamental constructs and principles, with limited theoretical basis. The results indicate that the modern strategies do not include essential aspects of systems theory that describe relationships and interdependencies between key components. The description of these strategies as systems is therefore not well founded and deserves further development. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Study on 'Safety qualification of process computers used in safety systems of nuclear power plants'

    International Nuclear Information System (INIS)

    Bertsche, K.; Hoermann, E.

    1991-01-01

    The study aims at developing safety standards for hardware and software of computer systems which are increasingly used also for important safety systems in nuclear power plants. The survey of the present state-of-the-art of safety requirements and specifications for safety-relevant systems and, additionally, for process computer systems has been compiled from national and foreign rules. In the Federal Republic of Germany the KTA safety guides and the BMI/BMU safety criteria have to be observed. For the design of future computer-aided systems in nuclear power plants it will be necessary to apply the guidelines in [DIN-880] and [DKE-714] together with [DIN-192]. With the aid of a risk graph the various functions of a system, or of a subsystem, can be evaluated with regard to their significance for safety engineering. (orig./HP) [de

  20. Design an optimum safety policy for personnel safety management - A system dynamic approach

    International Nuclear Information System (INIS)

    Balaji, P.

    2014-01-01

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamics model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making

  1. Design an optimum safety policy for personnel safety management - A system dynamic approach

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, P. [The Glocal University, Mirzapur Pole, Delhi- Yamuntori Highway, Saharanpur 2470001 (India)

    2014-10-06

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamics model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making.

  2. Design an optimum safety policy for personnel safety management - A system dynamic approach

    Science.gov (United States)

    Balaji, P.

    2014-10-01

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamics model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making.

  3. Nurses' decision-making process in cases of physical restraint in acute elderly care: a qualitative study.

    Science.gov (United States)

    Goethals, S; Dierckx de Casterlé, B; Gastmans, C

    2013-05-01

    The increasing vulnerability of patients in acute elderly care requires constant critical reflection in ethically charged situations such as when employing physical restraint. Qualitative evidence concerning nurses' decision making in cases of physical restraint is limited and fragmented. A thorough understanding of nurses' decision-making process could be useful to understand how nurses reason and make decisions in ethically laden situations. The aims of this study were to explore and describe nurses' decision-making process in cases of physical restraint. We used a qualitative interview design inspired by the Grounded Theory approach. Data analysis was guided by the Qualitative Analysis Guide of Leuven. Twelve hospitals geographically spread throughout the five provinces of Flanders, Belgium. Twenty-one acute geriatric nurses interviewed between October 2009 and April 2011 were purposively and theoretically selected, with the aim of including nurses having a variety of characteristics and experiences concerning decisions on using physical restraint. In cases of physical restraint in acute elderly care, nurses' decision making was never experienced as a fixed decision but rather as a series of decisions. Decision making was mostly reasoned upon and based on rational arguments; however, decisions were also made routinely and intuitively. Some nurses felt very certain about their decisions, while others experienced feelings of uncertainty regarding their decisions. Nurses' decision making is an independent process that requires nurses to obtain a good picture of the patient, to be constantly observant, and to assess and reassess the patient's situation. Coming to thoughtful and individualized decisions requires major commitment and constant critical reflection. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Restraint training for awake functional brain scanning of rodents can cause long-lasting changes in pain and stress responses.

    Science.gov (United States)

    Low, Lucie A; Bauer, Lucy C; Pitcher, Mark H; Bushnell, M Catherine

    2016-08-01

    With the increased interest in longitudinal brain imaging of awake rodents, it is important to understand both the short-term and long-term effects of restraint on sensory and emotional processing in the brain. To understand the effects of repeated restraint on pain behaviors and stress responses, we modeled a restraint protocol similar to those used to habituate rodents for magnetic resonance imaging scanning, and studied sensory sensitivity and stress hormone responses over 5 days. To uncover lasting effects of training, we also looked at responses to the formalin pain test 2 weeks later. We found that while restraint causes acute increases in the stress hormone corticosterone, it can also cause lasting reductions in nociceptive behavior in the formalin test, coupled with heightened corticosterone levels and increased activation of the "nociceptive" central nucleus of the amygdala, as seen by Fos protein expression. These results suggest that short-term repeated restraint, similar to that used to habituate rats for awake functional brain scanning, could potentially cause long-lasting changes in physiological and brain responses to pain stimuli that are stress-related, and therefore could potentially confound the functional activation patterns seen in awake rodents in response to pain stimuli.

  5. Meeting the maglev system's safety requirements

    Energy Technology Data Exchange (ETDEWEB)

    Pierick, K

    1983-12-01

    The author shows how the safety requirements of the maglev track system derive from the general legal conditions for the safety of tracked transport. It is described how their compliance beyond the so-called ''development-accompanying'' and ''acceptance-preparatory'' safety work can be assured for the Transrapid test layout (TVE) now building in Emsland and also for later application as public transport system in Germany within the meaning of the General Railway Act.

  6. An alternate and reversible method for flight restraint of cranes.

    Science.gov (United States)

    Zhang, Sen Lin; Yang, Shu Hui; Li, Bing; Xu, Yan Chun; Ma, Jian Hua; Xu, Jian Feng; Zhang, Xian Guang

    2011-01-01

    Flight restraint is important for zoos, safaris, and breeding centers for large birds. Currently used techniques for flight restraint include both surgical and non-surgical approaches. Surgical approaches usually cause permanent change to or removal of tendon, patagial membrane, or wing bones, and can cause pain and inflammation. Non-surgical approaches such as clipping or trimming feathers often alter the bird's appearance, and can damage growing blood feathers in fledglings or cause joint stiffness. We observed microstructure of primary feathers of the red-crowned crane (Grus japonensis) and found that the width of barbs is a determinative factor influencing vane stiffness and geometric parameters. We hypothesized that partial longitudinal excision of barbs on the ventral surface of the primary feathers would reduce the stiffness of the vane and render the feathers unable to support the crane's body weight during flight. Furthermore, we hypothesized that this modification of barbs would also change the aerodynamic performance of feathers such that they could not generate sufficient lift and thrust during flapping to enable the bird to fly. We tested this hypothesis on a red-crowned crane that had normal flight capability by excising the ventral margin of barbs on all 10 primaries on the left wing. The bird was unable to take off until the modified feathers were replaced by new ones. Removal of barbs proved to be a simple, non-invasive, low-cost and reversible method for flight restraint. It is potentially applicable to other large birds with similar structural characteristics of primary feathers. © 2010 Wiley-Liss, Inc.

  7. Strategy to safety grade systems replacements

    International Nuclear Information System (INIS)

    Stimler, M.; Sullivan, K.E.; Trebincevic, I.

    1993-01-01

    The introduction of digital instrumentation and control systems in nuclear power plants is characterized by the need to satisfy the requirements of safety, reliability and man-machine ergonomics. Today digital instrumentation and control systems meet these requirements and the trend in Europe is towards full digital based nuclear power plant control systems. This paper describes Siemens (KWU) experience in nuclear power plants and development in trends within Europe. Topics which are the subject of major concern to NPP operators addressed in this paper are: human performance factors - man-machine interface; operating philosophy; safety, availability and reliability. Other aspects addressed are: Siemens open-quotes defense in depthclose quotes concept, description of Siemens digital I ampersand C systems, safety requirements and systems, I ampersand C qualification, control room ergonomics, information systems and retrofitting experience

  8. System safety education focused on system management

    Science.gov (United States)

    Grose, V. L.

    1971-01-01

    System safety is defined and characteristics of the system are outlined. Some of the principle characteristics include role of humans in hazard analysis, clear language for input and output, system interdependence, self containment, and parallel analysis of elements.

  9. Safety Management System in Croatia Control Ltd.

    OpenAIRE

    Pavlin, Stanislav; Sorić, Vedran; Bilać, Dragan; Dimnik, Igor; Galić, Daniel

    2009-01-01

    International Civil Aviation Organization and other international aviation organizations regulate the safety in civil aviation. In the recent years the International Civil Aviation Organization has introduced the concept of the safety management system through several documents among which the most important is the 2006 Safety Management Manual. It treats the safety management system in all the segments of civil aviation, from carriers, aerodromes and air traffic control to design, constructi...

  10. Vortex induced vibrations in gapped restrainted pipes

    International Nuclear Information System (INIS)

    Veloso, P. de A.A.; Loula, A.F.D.

    1984-01-01

    The vortex induced vibration problem of gapped restrained piping is solved numerically. The model proposed by Skop-Griffin is used to describe the pipe-fluid interaction. The variational formulation is obtained modeling the gapped restraints as non-linear elastic springs. The regularized problem is solved using a finite element discretization for the spatial domain. In the time domain a finite difference discretization is used for the lift coefficient equatin and a Newmark discretization for the equation of motion. (Author) [pt

  11. Safety Evaluation Approach with Security Controls for Safety I and C Systems on Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, D. H.; Jeong, S. Y.; Kim, Y. M.; Park, H. S.; Lee, M. S.; Kim, T. H.

    2016-01-01

    This paper addresses concepts of safety and security and relations between them for assessing effects of security features in safety systems. Also, evaluation approach for avoiding confliction with safety requirements and cyber security features which may be adopted in safety-related digital I and C system will be described. In this paper, safety-security life cycle model based confliction avoidance method was proposed to evaluate the effects when the cyber security control features are implemented in the safety I and C system. Also, safety effect evaluation results using the proposed evaluation method were described. In case of technical security controls, many of them are expected to conflict with safety requirements, otherwise operational and managerial controls are not relatively. Safety measures and cyber security measures for nuclear power plants should be implemented not to conflict with one another. Where safety function and security features are both required within the systems, and also where security features are implemented within safety systems, they should be justified

  12. Safety Evaluation Approach with Security Controls for Safety I and C Systems on Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Jeong, S. Y.; Kim, Y. M.; Park, H. S. [KINS, Daejeon (Korea, Republic of); Lee, M. S.; Kim, T. H. [Formal Works Inc., Seoul (Korea, Republic of)

    2016-05-15

    This paper addresses concepts of safety and security and relations between them for assessing effects of security features in safety systems. Also, evaluation approach for avoiding confliction with safety requirements and cyber security features which may be adopted in safety-related digital I and C system will be described. In this paper, safety-security life cycle model based confliction avoidance method was proposed to evaluate the effects when the cyber security control features are implemented in the safety I and C system. Also, safety effect evaluation results using the proposed evaluation method were described. In case of technical security controls, many of them are expected to conflict with safety requirements, otherwise operational and managerial controls are not relatively. Safety measures and cyber security measures for nuclear power plants should be implemented not to conflict with one another. Where safety function and security features are both required within the systems, and also where security features are implemented within safety systems, they should be justified.

  13. Resisting force characteristics of a mechanical snubber and its restraint effect on beam deformation

    International Nuclear Information System (INIS)

    Ohmata, Kenichiro

    1987-01-01

    A mechanical snubber is used to restrain piping systems in nuclear power plants during an earthquake. It has nonlinearities in both load (or exciting amplitude) and frequency response, so it will be very difficult to analyze the resisting force characteristics of the mechanical snubber theoretically. In this report, the equation of motion of the mechanical snubber is derived and digital simulations of snubber dynamic characteristics over a frequency range are carried out using the Continuous System Simulation Language (CSSL). Also, the restraint effect of the mechanical snubber applied to a simple beam is discussed both numerically and experimentally. The beam is replaced by a lumped mass system and CSSL is used to perform the digital simulations. (author)

  14. Do emotion regulation difficulties when upset influence the association between dietary restraint and weight gain among college students?

    Science.gov (United States)

    Hunt, Tyler K; Forbush, Kelsie T; Hagan, Kelsey E; Chapa, Danielle A N

    2017-07-01

    Obesity is a significant public health concern that affects more than one-fifth of adolescents aged 12-19 in the United States. Theoretical models suggest that prolonged dietary restraint leads to binge-eating behaviors, which in turn increases individuals' risk for weight gain or obesity. Results from the literature indicate a potential role for negative urgency (the tendency to act rashly when distressed) as a mediating variable that explains the link between dietary restraint and binge-eating episodes. The current study tested short-term, prospective longitudinal associations among dietary restraint, binge eating, negative urgency, and weight gain among college students - a population at increased risk for the development of overweight and obesity. We hypothesized that dietary restraint and weight gain would be mediated by negative urgency and binge eating, but only among participants with overweight and obesity. College students (N = 227) completed the Eating Pathology Symptoms Inventory, UPPS-P Impulsivity Scale, and self-reported weight and height to calculate body mass index. Results showed that the association between dietary restraint and weight gain was mediated by negative urgency and binge eating, but only among participants with overweight and obesity. Our findings indicated that negative urgency might represent a mechanism that explains why dietary restraint leads to future binge-eating episodes and weight gain among college students with overweight and obesity. Results suggest that future treatment and prevention programs for overweight and obesity may benefit from incorporating strategies to improve emotion regulation as a way to reduce binge eating and to prevent additional weight gain among 'at-risk' populations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Safety-related control air systems - approved 1977

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  16. Qualification of FPGA-Based Safety-Related PRM System

    International Nuclear Information System (INIS)

    Miyazaki, Tadashi; Oda, Naotaka; Goto, Yasushi; Hayashi, Toshifumi

    2011-01-01

    Toshiba has developed Non-rewritable (NRW) Field Programmable Gate Array (FPGA)-based safety-related Instrumentation and Control (I and C) system. Considering application to safety-related systems, nonvolatile and non-rewritable FPGA which is impossible to be changed after once manufactured has been adopted in Toshiba FPGA-based system. FPGA is a device which consists only of basic logic circuits, and FPGA performs defined processing which is configured by connecting the basic logic circuit inside the FPGA. FPGA-based system solves issues existing both in the conventional systems operated by analog circuits (analog-based system) and the systems operated by central processing unit (CPU-based system). The advantages of applying FPGA are to keep the long-life supply of products, improving testability (verification), and to reduce the drift which may occur in analog-based system. The system which Toshiba developed this time is Power Range Neutron Monitor (PRM). Toshiba is planning to expand application of FPGA-based technology by adopting this development process to the other safety-related systems such as RPS from now on. Toshiba developed a special design process for NRW-FPGA-based safety-related I and C systems. The design process resolves issues for many years regarding testability of the digital system for nuclear safety application. Thus, Toshiba NRW-FPGA-based safety-related I and C systems has much advantage to be a would standard of the digital systems for nuclear safety application. (author)

  17. Safety climate and culture: Integrating psychological and systems perspectives.

    Science.gov (United States)

    Casey, Tristan; Griffin, Mark A; Flatau Harrison, Huw; Neal, Andrew

    2017-07-01

    Safety climate research has reached a mature stage of development, with a number of meta-analyses demonstrating the link between safety climate and safety outcomes. More recently, there has been interest from systems theorists in integrating the concept of safety culture and to a lesser extent, safety climate into systems-based models of organizational safety. Such models represent a theoretical and practical development of the safety climate concept by positioning climate as part of a dynamic work system in which perceptions of safety act to constrain and shape employee behavior. We propose safety climate and safety culture constitute part of the enabling capitals through which organizations build safety capability. We discuss how organizations can deploy different configurations of enabling capital to exert control over work systems and maintain safe and productive performance. We outline 4 key strategies through which organizations to reconcile the system control problems of promotion versus prevention, and stability versus flexibility. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Safety assessment of high consequence robotics system

    International Nuclear Information System (INIS)

    Robinson, D.G.; Atcitty, C.B.

    1996-01-01

    This paper outlines the use of a failure modes and effects analysis for the safety assessment of a robotic system being developed at Sandia National Laboratories. The robotic system, the weigh and leak check system, is to replace a manual process for weight and leakage of nuclear materials at the DOE Pantex facility. Failure modes and effects analyses were completed for the robotics process to ensure that safety goals for the systems have been met. Due to the flexible nature of the robot configuration, traditional failure modes and effects analysis (FMEA) were not applicable. In addition, the primary focus of safety assessments of robotics systems has been the protection of personnel in the immediate area. In this application, the safety analysis must account for the sensitivities of the payload as well as traditional issues. A unique variation on the classical FMEA was developed that permits an organized and quite effective tool to be used to assure that safety was adequately considered during the development of the robotic system. The fundamental aspects of the approach are outlined in the paper

  19. Quality of life of nursing-home residents with dementia subject ot surveillance technology versus physical restraints: an explorative study

    NARCIS (Netherlands)

    te Boekhorst, S.; Depla, M.F.I.A.; Francke, A.L.; Twisk, J.W.R.; Zwijsen, S.A.; Hertogh, C.M.P.M.

    2013-01-01

    Objective As physical restraints should only be used in exceptional cases, there is an urgent need for alternatives to restraint use. Surveillance technology could be such an alternative. This study explored whether nursing-home residents with dementia subjected to surveillance technology had better

  20. Quality of life of nursing-home residents with dementia subject to surveillance technology versus physical restraints: an explorative study.

    NARCIS (Netherlands)

    Boekhorst, S. te; Depla, M.F.I.A.; Francke, A.L.; Twisk, J.W.R.; Zwijsen, S.A.; Hertogh, C.M.P.M.

    2013-01-01

    Objective: As physical restraints should only be used in exceptional cases, there is an urgent need for alternatives to restraint use. Surveillance technology could be such an alternative. This study explored whether nursing-home residents with dementia subjected to surveillance technology had

  1. A formal safety analysis for PLC software-based safety critical system using Z

    International Nuclear Information System (INIS)

    Koh, Jung Soo

    1997-02-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formal safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system. And also, we have found that some errors or mismatches in user requirement and final implemented PLC ladder logic while analyzing the process of the consistency and completeness of Z translated formal specifications. In the case of relatively small systems like Beamline hutch door interlock system, a formal safety analysis including explicit proof is highly recommended so that the safety of PLC-based critical system may be enhanced and guaranteed. It also provides a helpful benefits enough to comprehend user requirement expressed by ambiguous natural language

  2. Activation of the HPA axis and depression of feeding behavior induced by restraint stress are separately regulated by PACAPergic neurotransmission in the mouse.

    Science.gov (United States)

    Jiang, Sunny Zhihong; Eiden, Lee E

    2016-07-01

    We measured serum CORT elevation in wild-type and PACAP-deficient C57BL/6N male mice after acute (1 h) or prolonged (2-3 h) daily restraint stress for 7 d. The PACAP dependence of CORT elevation was compared to that of stress-induced hypophagia. Daily restraint induced unhabituated peak CORT elevation, and hypophagia/weight loss, of similar magnitude for 1, 2, and 3 h of daily restraint, in wild-type mice. Peak CORT elevation, and hypophagia, were both attenuated in PACAP-deficient mice for 2 and 3 h daily restraint. Hypophagia induced by 1-h daily restraint was also greatly reduced in PACAP-deficient mice, however CORT elevation, both peak and during recovery from stress, was unaffected. Thus, hypothalamic PACAPergic neurotransmission appears to affect CRH gene transcription and peptide production, but not CRH release, in response to psychogenic stress. A single exposure to restraint sufficed to trigger hypophagia over the following 24 h. PACAP deficiency attenuated HPA axis response (CORT elevation) to prolonged (3 h) but not acute (1 h) single-exposure restraint stress, while hypophagia induced by either a single 1 h or a single 3 h restraint were both abolished in PACAP-deficient mice. These results suggest that PACAP's actions to promote suppression of food intake following an episode of psychogenic stress is unrelated to the release of CRH into the portal circulation to activate the pituitary-adrenal axis. Furthermore, demonstration of suppressed food intake after a single 1-h restraint stress provides a convenient assay for investigating the location of the synapses and circuits mediating the effects of PACAP on the behavioral sequelae of psychogenic stress.

  3. The evolution of the doctrine of restraint of trade in Australia: a law reform perspective

    OpenAIRE

    Cheng, John Wei-Ting

    2017-01-01

    This thesis examines the present state of the common law doctrine of restraint of trade from a law reform perspective. The doctrine was developed in England between the 1600s and mid-1800s and its evolution over the centuries has been a slow and ongoing process. The present state of the doctrine and its application in the Australian jurisdiction presents a challenging set of circumstances due to the difficulties faced by contracting parties when they wish to engage in restraint of trade. ...

  4. Quantitative safety assessment of air traffic control systems through system control capacity

    Science.gov (United States)

    Guo, Jingjing

    Quantitative Safety Assessments (QSA) are essential to safety benefit verification and regulations of developmental changes in safety critical systems like the Air Traffic Control (ATC) systems. Effectiveness of the assessments is particularly desirable today in the safe implementations of revolutionary ATC overhauls like NextGen and SESAR. QSA of ATC systems are however challenged by system complexity and lack of accident data. Extending from the idea "safety is a control problem" in the literature, this research proposes to assess system safety from the control perspective, through quantifying a system's "control capacity". A system's safety performance correlates to this "control capacity" in the control of "safety critical processes". To examine this idea in QSA of the ATC systems, a Control-capacity Based Safety Assessment Framework (CBSAF) is developed which includes two control capacity metrics and a procedural method. The two metrics are Probabilistic System Control-capacity (PSC) and Temporal System Control-capacity (TSC); each addresses an aspect of a system's control capacity. And the procedural method consists three general stages: I) identification of safety critical processes, II) development of system control models and III) evaluation of system control capacity. The CBSAF was tested in two case studies. The first one assesses an en-route collision avoidance scenario and compares three hypothetical configurations. The CBSAF was able to capture the uncoordinated behavior between two means of control, as was observed in a historic midair collision accident. The second case study compares CBSAF with an existing risk based QSA method in assessing the safety benefits of introducing a runway incursion alert system. Similar conclusions are reached between the two methods, while the CBSAF has the advantage of simplicity and provides a new control-based perspective and interpretation to the assessments. The case studies are intended to investigate the

  5. Upgrading safety systems of industrial irradiation facilities

    International Nuclear Information System (INIS)

    Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Costa, M.L.L.; Thomé, Z.D.

    2017-01-01

    The first industrial irradiation facility in operation in Brazil was designed in the 70s. Nowadays, twelve commercial and research facilities are in operation and two already decommissioned. Minor modifications and upgrades, as sensors replacement, have been introduced in these facilities, in order to reduce the technological gap in the control and safety systems. The safety systems are designed in agreement with the codes and standards at the time. Since then, new standards, codes and recommendations, as well as lessons learned from accidents, have been issued by various international committees or regulatory bodies. The rapid advance of the industry makes the safety equipment used in the original construction become obsolete. The decreasing demand for these older products means that they are no longer produced, which can make it impossible or costly to obtain spare parts and the expansion of legacy systems to include new features. This work aims to evaluate existing safety systems at Brazilian irradiation facilities, mainly the oldest facilities, taking into account the recommended IAEA's design requirements. Irrespective of the fact that during its operational period no event with victims have been recorded in Brazilian facilities, and that the regulatory inspections do not present any serious deviations regarding the safety procedures, it is necessary an assessment of safety system with the purpose of bringing their systems to 'the state of the art', avoiding their rapid obsolescence. This study has also taken into account the knowledge, concepts and solutions developed to upgrading safety system in irradiation facilities throughout the world. (author)

  6. Upgrading safety systems of industrial irradiation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, R.S.; Gomes, J.D.R.L.; Costa, E.L.C.; Costa, M.L.L., E-mail: rogeriog@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: evaldo@cnen.gov.br, E-mail: mara@cnen.gov.br [Comissão Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Thomé, Z.D., E-mail: zielithome@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-07-01

    The first industrial irradiation facility in operation in Brazil was designed in the 70s. Nowadays, twelve commercial and research facilities are in operation and two already decommissioned. Minor modifications and upgrades, as sensors replacement, have been introduced in these facilities, in order to reduce the technological gap in the control and safety systems. The safety systems are designed in agreement with the codes and standards at the time. Since then, new standards, codes and recommendations, as well as lessons learned from accidents, have been issued by various international committees or regulatory bodies. The rapid advance of the industry makes the safety equipment used in the original construction become obsolete. The decreasing demand for these older products means that they are no longer produced, which can make it impossible or costly to obtain spare parts and the expansion of legacy systems to include new features. This work aims to evaluate existing safety systems at Brazilian irradiation facilities, mainly the oldest facilities, taking into account the recommended IAEA's design requirements. Irrespective of the fact that during its operational period no event with victims have been recorded in Brazilian facilities, and that the regulatory inspections do not present any serious deviations regarding the safety procedures, it is necessary an assessment of safety system with the purpose of bringing their systems to 'the state of the art', avoiding their rapid obsolescence. This study has also taken into account the knowledge, concepts and solutions developed to upgrading safety system in irradiation facilities throughout the world. (author)

  7. 'Mechanical restraint-confounders, risk, alliance score': testing the clinical validity of a new risk assessment instrument.

    Science.gov (United States)

    Deichmann Nielsen, Lea; Bech, Per; Hounsgaard, Lise; Alkier Gildberg, Frederik

    2017-08-01

    Unstructured risk assessment, as well as confounders (underlying reasons for the patient's risk behaviour and alliance), risk behaviour, and parameters of alliance, have been identified as factors that prolong the duration of mechanical restraint among forensic mental health inpatients. To clinically validate a new, structured short-term risk assessment instrument called the Mechanical Restraint-Confounders, Risk, Alliance Score (MR-CRAS), with the intended purpose of supporting the clinicians' observation and assessment of the patient's readiness to be released from mechanical restraint. The content and layout of MR-CRAS and its user manual were evaluated using face validation by forensic mental health clinicians, content validation by an expert panel, and pilot testing within two, closed forensic mental health inpatient units. The three sub-scales (Confounders, Risk, and a parameter of Alliance) showed excellent content validity. The clinical validations also showed that MR-CRAS was perceived and experienced as a comprehensible, relevant, comprehensive, and useable risk assessment instrument. MR-CRAS contains 18 clinically valid items, and the instrument can be used to support the clinical decision-making regarding the possibility of releasing the patient from mechanical restraint. The present three studies have clinically validated a short MR-CRAS scale that is currently being psychometrically tested in a larger study.

  8. The concept of restraints in nursing home practice: a mixed method study in nursing homes for people with dementia.

    NARCIS (Netherlands)

    Zwijsen, S.A.; Depla, M.F.I.A.; Niemeijer, A.R.; Francke, A.L.; Hertogh, C.M.P.M.

    2011-01-01

    Introduction: Although in most developed countries the use of restraints is regulated and restricted by law, the concept of restraint in nursing home care remains ambiguous. This study aims to explore how care professionals and family members of nursing home residents with dementia in the

  9. Allometric scaling of chemical restraint associated with inhalant anesthesia in giant anteaters.

    Science.gov (United States)

    Carregaro, Adriano Bonfim; Gerardi, Patrícia Molina; Honsho, Daniel Kan

    2009-04-01

    This study describes the use of allometric scaling in five giant anteaters (Myrmecophaga tridactyla) submitted for osteosynthesis, gastrostomy, or treatment of burns. Chemical restraint was performed by allometric scaling using the dog as a reference; acepromazine (0.06 mg/kg), diazepam (0.3 mg/kg), ketamine (8.8 mg/kg), and buprenorphine (5.9 microg/kg) were combined, and the animals were maintained under isoflurane anesthesia. Heart rate, respiratory rate, hemoglobin oxygen saturation, temperature, and anesthetic depth were measured. Postoperative treatment consisted of ketoprofen, buprenorphine, and ceftiofur. Anesthetic induction was obtained in 10-15 min, achieving muscle relaxation and absence of excitement. Physiologic parameters were stable during the procedures, and postoperative treatment was effective. Allometric scaling was effective for chemical restraint and postoperative treatment.

  10. Safety status system for operating room devices.

    Science.gov (United States)

    Guédon, Annetje C P; Wauben, Linda S G L; Overvelde, Marlies; Blok, Joleen H; van der Elst, Maarten; Dankelman, Jenny; van den Dobbelsteen, John J

    2014-01-01

    Since the increase of the number of technological aids in the operating room (OR), equipment-related incidents have come to be a common kind of adverse events. This underlines the importance of adequate equipment management to improve the safety in the OR. A system was developed to monitor the safety status (periodic maintenance and registered malfunctions) of OR devices and to facilitate the notification of malfunctions. The objective was to assess whether the system is suitable for use in an busy OR setting and to analyse its effect on the notification of malfunctions. The system checks automatically the safety status of OR devices through constant communication with the technical facility management system, informs the OR staff real-time and facilitates notification of malfunctions. The system was tested for a pilot period of six months in four ORs of a Dutch teaching hospital and 17 users were interviewed on the usability of the system. The users provided positive feedback on the usability. For 86.6% of total time, the localisation of OR devices was accurate. 62 malfunctions of OR devices were reported, an increase of 12 notifications compared to the previous year. The safety status system was suitable for an OR complex, both from a usability and technical point of view, and an increase of reported malfunctions was observed. The system eases monitoring the safety status of equipment and is a promising tool to improve the safety related to OR devices.

  11. Plant air systems safety study: Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    1982-05-01

    The Portsmouth Gaseous Diffusion Plant Air System facilities and operations are reviewed for potential safety problems not covered by standard industrial safety procedures. Information is presented under the following section headings: facility and process description (general); air plant equipment; air distribution system; safety systems; accident analysis; plant air system safety overview; and conclusion

  12. A philosophy for space nuclear systems safety

    International Nuclear Information System (INIS)

    Marshall, A.C.

    1992-01-01

    The unique requirements and contraints of space nuclear systems require careful consideration in the development of a safety policy. The Nuclear Safety Policy Working Group (NSPWG) for the Space Exploration Initiative has proposed a hierarchical approach with safety policy at the top of the hierarchy. This policy allows safety requirements to be tailored to specific applications while still providing reassurance to regulators and the general public that the necessary measures have been taken to assure safe application of space nuclear systems. The safety policy used by the NSPWG is recommended for all space nuclear programs and missions

  13. Intensive care unit nurses' perceptions of safety after a highly specific safety intervention.

    Science.gov (United States)

    Elder, N C; Brungs, S M; Nagy, M; Kudel, I; Render, M L

    2008-02-01

    It is unknown if successful changes in specific safety practices in the intensive care unit (ICU) generalize to broader concepts of patient safety by staff nurses. To explore perceptions of patient safety among nursing staff in ICUs following participation in a safety project that decreased hospital acquired infections. After implementation of practices that reduced catheter-related bloodstream infections in ICUs at four community hospitals, ICU nurses participated in focus groups to discuss patient safety. Audiotapes from the focus groups were transcribed, and two independent reviewers categorised the data which were triangulated with responses from selected questions of safety climate surveys and with the safety checklists used by management leadership on walk rounds. Thirty-three nurses attended eight focus groups; 92 nurses and managers completed safety climate surveys, and three separate leadership checklists were reviewed. In focus groups, nurses predominantly related patient safety to dangers in the physical environment (eg, bed rails, alarms, restraints, equipment, etc.) and to medication administration. These areas also represented 47% of checklist items from leadership walk rounds. Nurses most frequently mentioned self-initiated "double checking" as their main safety task. Focus-group participants and survey responses both noted inconsistency between management's verbal and written commitment compared with their day-to-day support of patient safety issues. ICU nurses who participated in a project to decrease hospital acquired infections did not generalize their experience to other aspects of patient safety or relate it to management's interest in patient safety. These findings are consistent with many adult learning theories, where self-initiated tasks, combined with immediate, but temporary problem-solving, are stronger learning forces than management-led activities with delayed feedback.

  14. The safety interlocking system at the NAC

    International Nuclear Information System (INIS)

    Visser, K.; Mostert, H.

    1984-01-01

    The central safety interlocking system (CSIS) controls the higher level of interlocking between the various cyclotron subsystems. It ensures the safe operation of the entire cyclotron facility as regards personnel safety and proper instrument operation. The system consists of a micro-processor with a ROM-based safety interlocking program, relay output modules providing ''safety OK'' instructions to all interlocked apparatus, alarm input modules connected to transducers providing binary alarm status signals and an interface to the central control computer. All solid state electronic components of the system are situated in a low level radiation area and are interfaced to cyclotron equipment by means of 24 V relays

  15. Safety Verification for Probabilistic Hybrid Systems

    DEFF Research Database (Denmark)

    Zhang, Lijun; She, Zhikun; Ratschan, Stefan

    2010-01-01

    The interplay of random phenomena and continuous real-time control deserves increased attention for instance in wireless sensing and control applications. Safety verification for such systems thus needs to consider probabilistic variations of systems with hybrid dynamics. In safety verification o...... on a number of case studies, tackled using a prototypical implementation....

  16. A management system integrating radiation protection and safety supporting safety culture in the hospital

    International Nuclear Information System (INIS)

    Almen, A.; Lundh, C.

    2015-01-01

    Quality assurance has been identified as an important part of radiation protection and safety for a considerable time period. A rational expansion and improvement of quality assurance is to integrate radiation protection and safety in a management system. The aim of this study was to explore factors influencing the implementing strategy when introducing a management system including radiation protection and safety in hospitals and to outline benefits of such a system. The main experience from developing a management system is that it is possible to create a vast number of common policies and routines for the whole hospital, resulting in a cost-efficient system. One of the key benefits is the involvement of management at all levels, including the hospital director. Furthermore, a transparent system will involve staff throughout the organisation as well. A management system supports a common view on what should be done, who should do it and how the activities are reviewed. An integrated management system for radiation protection and safety includes key elements supporting a safety culture. (authors)

  17. Exposure of pregnant rats to uranium and restraint stress: Effects on postnatal development and behavior of the offspring

    International Nuclear Information System (INIS)

    Sanchez, Domenec J.; Belles, Montserrat; Albina, Maria L.; Gomez, Mercedes; Linares, Victoria; Domingo, Jose L.

    2006-01-01

    The effects on postnatal development and behavior were assessed in the offspring of female rats concurrently exposed to uranium (U) and restraint stress. Adult female rats were administered uranyl acetate dihydrate (UAD) in the drinking water at doses of 0, 40 and 80 mg/(kg day) for 4 weeks before mating with untreated males, as well as during pregnancy and lactation. One-half of female rats in each group were concurrently subjected to restraint (2 h/day). On gestation day 14, one-half of restrained and unrestrained rats were sacrificed in order to evaluate maternal toxicity and gestational parameters. Pups were evaluated for physical development, neuromotor maturation, and behavior. Uranium concentrations were also determined in various tissues of dams and fetuses. In all uranium-treated groups, the highest concentrations of this element were found in kidney and bone, being considerably higher than those in brain. Uranium levels in tissues of dam or fetuses were not significantly affected by restraint. No significant interactions between uranium and restraint could be observed in maternal toxicity. Moreover, no relevant effects of uranium, maternal restraint, or their combination were noted on developmental landmarks in the offspring. In the passive avoidance test, at 40 and 80 mg UAD/(kg day) restraint significantly modified passive avoidance acquisition (T1) and retention time (T2) 24 h later. However, no significant differences were observed on the Morris water maze test. The results of the present study indicate that, in general terms, exposure of female rats to UAD before mating with untreated males, as well as during gestation and lactation, did not cause relevant dose-related adverse effects on postnatal development and behavior of the offspring. The influence of stress was very limited

  18. Regulatory Oversight of Safety Culture in Finland: A Systemic Approach to Safety

    International Nuclear Information System (INIS)

    Oedewald, P.; Väisäsvaara, J.

    2016-01-01

    In Finland the Radiation and Nuclear Safety Authority STUK specifies detailed regulatory requirements for good safety culture. Both the requirements and the practical safety culture oversight activities reflect a systemic approach to safety: the interconnections between the technical, human and organizational factors receive special attention. The conference paper aims to show how the oversight of safety culture can be integrated into everyday oversight activities. The paper also emphasises that the scope of the safety culture oversight is not specific safety culture activities of the licencees, but rather the overall functioning of the licence holder or the new build project organization from safety point of view. The regulatory approach towards human and organizational factors and safety culture has evolved throughout the years of nuclear energy production in Finland. Especially the recent new build projects have highlighted the need to systematically pay attention to the non-technical aspects of safety as it has become obvious how the HOF issues can affect the design processes and quality of construction work. Current regulatory guides include a set of safety culture related requirements. The requirements are binding to the licence holders and they set both generic and specific demands on the licencee to understand, monitor and to develop safety culture of their own organization but also that of their supplier network. The requirements set for the licence holders has facilitated the need to develop the regulator’s safety culture oversight practices towards a proactive and systemic approach.

  19. Reducing and Eliminating Restraint of People with Developmental Disabilities and Severe Behavior Disorders: An Overview of Recent Research

    Science.gov (United States)

    Williams, Don E.

    2010-01-01

    This paper provides a brief overview of the most recent research (1999-2009) on restraint reduction and elimination efforts in the literature and also examines the characteristics of restraint along with the risks and benefits. Some earlier papers were included in this review because of their importance to the topic. The results of this literature…

  20. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  1. Staff Training Reduces the Use of Physical Restraint in Mental Health Service, Evidence-based Reflection for China.

    Science.gov (United States)

    Ye, Junrong; Xiao, Aixiang; Yu, Lin; Guo, Jianxiong; Lei, Huawei; Wei, Hongmei; Luo, Wei

    2018-06-01

    The purpose of this article was to synthesize the evidence regarding the reduction of physical restraint, and to seek some practical recommendations based on the current situation in China. Nine databases were retrieved; these were PubMed, CINAHL, MEDLINE, Trip Database, PsysINFO, Cochrane Library, CNKI (Chinese database), Wanfang (Chinese database) and CBM (Chinese database) respectively. The selected articles were screened manually, and the identified researches were appraised through Review manager 5.3. Eight studies (four randomized controlled trials and four quasi-experimental studies) published between June 2013 and May 2017 were selected. Risk ratios (RRs) with 95% confidence intervals (CIs) were used as the effect index for dichotomous variables. The standardized mean differences (SMDs) with 95% CIs were calculated as the pooled continuous effect. The outcome of meta-analysis suggested staff training reduced the duration (IV=-0.88; 95% CIs=-1.65 to -0.10; Z=2.22; p=0.03) and adverse effect (RR, 0.16; 95% CIs=0.09 to 0.30; Z=5.96; pstaff training had no effects on the incidence of physical restraint. (RR, 1.01; 95% CIs=0.45 to 2.24; Z=0.02; p=0.99) CONCLUSION: Staff training was an effective measure to minimize the duration and adverse effects of physical restraint. More studies are needed to examine the effectiveness of staff training in relation to reduce the prevalence of physical restraint. Furthermore, considering the nurse's education background in China, it is recommended to conduct a compulsory training program to reduce the unnecessary restraint. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Factors Associated With the Trend of Physical and Chemical Restraint Use Among Long-Term Care Facility Residents in Hong Kong: Data From an 11-Year Observational Study.

    Science.gov (United States)

    Lam, Kuen; Kwan, Joseph S K; Wai Kwan, Chi; Chong, Alice M L; Lai, Claudia K Y; Lou, Vivian W Q; Leung, Angela Y M; Liu, Justina Y W; Bai, Xue; Chi, Iris

    2017-12-01

    Negative effects of restraint use have been well-documented. However, the prevalence of restraints use has been high in long-term care facilities in Hong Kong compared with other countries and this goes against the basic principles of ethical and compassionate care for older people. The present study aimed to review the change in the prevalence of physical and chemical restraint use in long-term care facilities (LTCFs) over a period of 11 years in Hong Kong and to identify the major factors associated with their use. This is an observational study with data obtained from the Hong Kong Longitudinal Study on LTCF Residents between 2005 and 2015. Trained assessors (nurses, social workers, and therapists) used the Minimum Data Set Resident Assessment Instrument to collect the data from 10 residential LTCFs. Physical restraint was defined as the use of any of the following: full bedside rails on all open sides of bed, other types of bedside rails used, trunk restraint, limb restraint, or the use of chair to prevent rising during the past 7 days. Chemical restraint was defined as the use of any of the following medications: antipsychotic, antianxiety, or hypnotic agents during past 7 days, excluding elder residents with a diagnosis of psychiatric illness. Annual prevalence of restraint use over 11 years and factors that were associated with the use of physical and chemical restraints. We analyzed the data for 2896 older people (978 male individuals, mean age = 83.3 years). Between 2005 and 2015, the prevalence of restraint use was as follows: physical restraint use increased from 52.7% to 70.2%; chemical restraint use increased from 15.9% to 21.78%; and either physical or chemical restraint use increased from 57.9% to 75.7%. Physical restraint use was independently associated with older age, impaired activities of daily living or cognitive function, bowel and bladder incontinence, dementia, and negative mood. Chemical restraint use was independently associated

  3. The ATLAS Detector Safety System

    CERN Multimedia

    Helfried Burckhart; Kathy Pommes; Heidi Sandaker

    The ATLAS Detector Safety System (DSS) has the mandate to put the detector in a safe state in case an abnormal situation arises which could be potentially dangerous for the detector. It covers the CERN alarm severity levels 1 and 2, which address serious risks for the equipment. The highest level 3, which also includes danger for persons, is the responsibility of the CERN-wide system CSAM, which always triggers an intervention by the CERN fire brigade. DSS works independently from and hence complements the Detector Control System, which is the tool to operate the experiment. The DSS is organized in a Front- End (FE), which fulfills autonomously the safety functions and a Back-End (BE) for interaction and configuration. The overall layout is shown in the picture below. ATLAS DSS configuration The FE implementation is based on a redundant Programmable Logical Crate (PLC) system which is used also in industry for such safety applications. Each of the two PLCs alone, one located underground and one at the s...

  4. Systems engineered health and safety criteria for safety analysis reports

    International Nuclear Information System (INIS)

    Beitel, G.A.; Morcos, N.

    1993-01-01

    The world of safety analysis is filled with ambiguous words: codes and standards, consequences and risks, hazard and accident, and health and safety. These words have been subject to disparate interpretations by safety analysis report (SAR) writers, readers, and users. open-quotes Principal health and safety criteriaclose quotes has been one of the most frequently misused phrases; rarely is it used consistently or effectively. This paper offers an easily understood definition for open-quotes principal health and safety criteriaclose quotes and uses systems engineering to convert an otherwise mysterious topic into the primary means of producing an integrated SAR. This paper is based on SARs being written for environmental restoration and waste management activities for the U.S. Department of Energy (DOE). Requirements for these SARs are prescribed in DOE Order 5480-23, open-quotes Nuclear Safety Analysis Reports.close quotes

  5. LOFT integral test system final safety analysis report

    International Nuclear Information System (INIS)

    1974-03-01

    Safety analyses are presented for the following LOFT Reactor systems: engineering safety features; support buildings and facilities; instrumentation and controls; electrical systems; and auxiliary systems. (JWR)

  6. "I cry every day and night, I have my son tied in chains": physical restraint of people with schizophrenia in community settings in Ethiopia.

    Science.gov (United States)

    Asher, Laura; Fekadu, Abebaw; Teferra, Solomon; De Silva, Mary; Pathare, Soumitra; Hanlon, Charlotte

    2017-07-11

    A primary rationale for scaling up mental health services in low and middle-income countries is to address human rights violations, including physical restraint in community settings. The voices of those with intimate experiences of restraint, in particular people with mental illness and their families, are rarely heard. The aim of this study was to understand the experiences of, and reasons for, restraint of people with schizophrenia in community settings in rural Ethiopia in order to develop constructive and scalable interventions. A qualitative study was conducted, involving 15 in-depth interviews and 5 focus group discussions (n = 35) with a purposive sample of people with schizophrenia, their caregivers, community leaders and primary and community health workers in rural Ethiopia. Thematic analysis was used. Most of the participants with schizophrenia and their caregivers had personal experience of the practice of restraint. The main explanations given for restraint were to protect the individual or the community, and to facilitate transportation to health facilities. These reasons were underpinned by a lack of care options, and the consequent heavy family burden and a sense of powerlessness amongst caregivers. Whilst there was pervasive stigma towards people with schizophrenia, lack of awareness about mental illness was not a primary reason for restraint. All types of participants cited increasing access to treatment as the most effective way to reduce the incidence of restraint. Restraint in community settings in rural Ethiopia entails the violation of various human rights, but the underlying human rights issue is one of lack of access to treatment. The scale up of accessible and affordable mental health care may go some way to address the issue of restraint. Clinicaltrials.gov NCT02160249 Registered 3rd June 2014.

  7. Effective applied moment in circumferential through-wall cracked pipes for leak-before-break evaluation considering pipe restraint effects

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeji; Hwang, Il-Soon [Seoul National University, Seoul 08826 (Korea, Republic of); Oh, Young-Jin, E-mail: yjoh2@kepco-enc.com [KEPCO Engineering and Construction Co. Inc., Gimcheon 39660 (Korea, Republic of)

    2016-05-15

    Highlights: • Effective applied moment at pipe cracked section considering the pipe restraint effect. • Verification of the proposed evaluation methods using finite element analyses. • Applicability for distributed external load of the proposed methods. - Abstract: In the leak-before-break (LBB) design of nuclear power plants, crack opening displacement (COD) is an essential element for determining the length of the leakage size crack. Recent researches regarding the evaluation of COD have indicated that the current practice of the LBB evaluation without consideration of the pressure induced bending (PIB) restraint overestimates COD, which in turn gives non-conservative results. Under a free-ended boundary condition, however, the applied moment at cracked section also can be overestimated, which has conservative effects on LBB evaluation. Therefore, it is necessary to evaluate pipe restraint effects on the applied moment as well as on COD to keep the constancy. In this paper, an evaluation method for the effect of the PIB restraint on COD and an effective applied moment (=crack driving force) at cracked section was developed. Both the linear elastic and elastic–plastic behaviors of the crack were considered. By comparing the behaviors with 3-D finite element analysis results from earlier studies, it was confirmed that the proposed methods make accurate estimations of the PIB restraint effect on COD. Next, the applicability of the proposed method to other types of external loading conditions was examined.

  8. Analyzing Software Requirements Errors in Safety-Critical, Embedded Systems

    Science.gov (United States)

    Lutz, Robyn R.

    1993-01-01

    This paper analyzes the root causes of safety-related software errors in safety-critical, embedded systems. The results show that software errors identified as potentially hazardous to the system tend to be produced by different error mechanisms than non- safety-related software errors. Safety-related software errors are shown to arise most commonly from (1) discrepancies between the documented requirements specifications and the requirements needed for correct functioning of the system and (2) misunderstandings of the software's interface with the rest of the system. The paper uses these results to identify methods by which requirements errors can be prevented. The goal is to reduce safety-related software errors and to enhance the safety of complex, embedded systems.

  9. Greater physiological and behavioral effects of interrupted stress pattern compared to daily restraint stress in rats.

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    Full Text Available Repeated stress can trigger a range of psychiatric disorders, including anxiety. The propensity to develop abnormal behaviors after repeated stress is related to the severity, frequency and number of stressors. However, the pattern of stress exposure may contribute to the impact of stress. In addition, the anxiogenic nature of repeated stress exposure can be moderated by the degree of coping that occurs, and can be reflected in homotypic habituation to the repeated stress. However, expectations are not clear when a pattern of stress presentation is utilized that diminishes habituation. The purpose of these experiments is to test whether interrupted stress exposure decreases homotypic habituation and leads to greater effects on anxiety-like behavior in adult male rats. We found that repeated interrupted restraint stress resulted in less overall homotypic habituation compared to repeated daily restraint stress. This was demonstrated by greater production of fecal boli and greater corticosterone response to restraint. Furthermore, interrupted restraint stress resulted in a lower body weight and greater adrenal gland weight than daily restraint stress, and greater anxiety-like behavior in the elevated plus maze. Control experiments demonstrated that these effects of the interrupted pattern could not be explained by differences in the total number of stress exposures, differences in the total number of days that the stress periods encompased, nor could it be explained as a result of only the stress exposures after an interruption from stress. These experiments demonstrate that the pattern of stress exposure is a significant determinant of the effects of repeated stress, and that interrupted stress exposure that decreases habituation can have larger effects than a greater number of daily stress exposures. Differences in the pattern of stress exposure are therefore an important factor to consider when predicting the severity of the effects of repeated

  10. Forensic mental health clinician's experiences with and assessment of alliance regarding the patient's readiness to be released from mechanical restraint

    DEFF Research Database (Denmark)

    Nielsen, Lea Deichmann; Gildberg, Frederik Alkier; Bech, Per

    2018-01-01

    One of the main reasons for prolonged duration of mechanical restraint is patient behaviour in relation to the clinician-patient alliance. This article reports on the forensic mental health clinicians experiences of the clinician-patient alliance during mechanical restraint, and their assessment...

  11. Dietary restraint in college women : Fear of an imperfect fat self is stronger than hope of a perfect thin self

    NARCIS (Netherlands)

    Dalley, Simon E.; Toffanin, Paolo; Pollet, Thomas V.

    We predicted that the perceived likelihood of acquiring a hoped-for thin self would mediate perfectionistic strivings on dietary restraint, and that the perceived likelihood of acquiring a feared fat self would mediate perfectionistic concerns on dietary restraint. We also predicted that the

  12. Dietary restraint in college women: Fear of an imperfect fat self is stronger than hope of a perfect thin self

    NARCIS (Netherlands)

    Dalley, S.E.; Toffanin, P.; Pollet, T.V.

    2012-01-01

    We predicted that the perceived likelihood of acquiring a hoped-for thin self would mediate perfectionistic strivings on dietary restraint, and that the perceived likelihood of acquiring a feared fat self would mediate perfectionistic concerns on dietary restraint. We also predicted that the

  13. Comparative Performance of Rear Facing Child Restraint Systems on the CMVSS 213 Bench and Vehicle Seats

    Science.gov (United States)

    Tylko, Suzanne; Locey, Caitlin M.; Garcia-Espana, J. Felipe; Arbogast, Kristy B.; Maltese, Matthew R.

    2013-01-01

    The purpose of this study was to compare the dynamic response of rear-facing child restraint systems (RFCRS) installed on the CMVSS 213 sled bench and a selection of vehicle seats. Thirty-six sled tests were conducted: three models of rear facing CRS with an anthropomorphic test device (ATD) representing a 12 month old child (CRABI) were affixed via lower anchors (LATCH), 3 point belt without CRS base, and 3 point belt with CRS base to one of three vehicle seats or the CMVSS 213 bench seat. All CRS were subjected to an identical sled acceleration pulse. Two types of matched pair analysis: “bench-to-vehicle” and “method of attachment” were conducted. Statistically significant differences were observed in the kinematic responses of the ATD and the CRS. This is the first study to quantify differences between the regulatory bench and vehicle seats on a system level and evaluate the influence of attachment method. Our results show that the difference in RFCRS forward excursion between 3-point belt with base and LATCH installations was between 1 and 7 percent on the bench and 22 to 76 percent on the vehicle seats. When evaluating the dynamic performance of RFCRS, the use of real vehicle seats from vehicles that commonly carry children may provide valuable insight. The findings would require further confirmation using a broader selection of RFCRS and vehicle seats, before generalizable conclusions can be drawn. PMID:24406967

  14. The Cost of Prior Restraint: "U. S. v. The Progressive."

    Science.gov (United States)

    Soloski, John; Dyer, Carolyn Stewart

    Increased litigation and rising litigation costs threaten the future of newspapers and magazines. A case study was conducted to determine the costs and effects of "United States v. 'The Progressive,'" a prior restraint case over the publication in 1979 of an article on the hydrogen bomb. "The Progressive," which operates at a…

  15. Using system dynamics simulation for assessment of hydropower system safety

    Science.gov (United States)

    King, L. M.; Simonovic, S. P.; Hartford, D. N. D.

    2017-08-01

    Hydropower infrastructure systems are complex, high consequence structures which must be operated safely to avoid catastrophic impacts to human life, the environment, and the economy. Dam safety practitioners must have an in-depth understanding of how these systems function under various operating conditions in order to ensure the appropriate measures are taken to reduce system vulnerability. Simulation of system operating conditions allows modelers to investigate system performance from the beginning of an undesirable event to full system recovery. System dynamics simulation facilitates the modeling of dynamic interactions among complex arrangements of system components, providing outputs of system performance that can be used to quantify safety. This paper presents the framework for a modeling approach that can be used to simulate a range of potential operating conditions for a hydropower infrastructure system. Details of the generic hydropower infrastructure system simulation model are provided. A case study is used to evaluate system outcomes in response to a particular earthquake scenario, with two system safety performance measures shown. Results indicate that the simulation model is able to estimate potential measures of system safety which relate to flow conveyance and flow retention. A comparison of operational and upgrade strategies is shown to demonstrate the utility of the model for comparing various operational response strategies, capital upgrade alternatives, and maintenance regimes. Results show that seismic upgrades to the spillway gates provide the largest improvement in system performance for the system and scenario of interest.

  16. Analysis of Aviation Safety Reporting System Incident Data Associated with the Technical Challenges of the System-Wide Safety and Assurance Technologies Project

    Science.gov (United States)

    Withrow, Colleen A.; Reveley, Mary S.

    2015-01-01

    The Aviation Safety Program (AvSP) System-Wide Safety and Assurance Technologies (SSAT) Project asked the AvSP Systems and Portfolio Analysis Team to identify SSAT-related trends. SSAT had four technical challenges: advance safety assurance to enable deployment of NextGen systems; automated discovery of precursors to aviation safety incidents; increasing safety of human-automation interaction by incorporating human performance, and prognostic algorithm design for safety assurance. This report reviews incident data from the NASA Aviation Safety Reporting System (ASRS) for system-component-failure- or-malfunction- (SCFM-) related and human-factor-related incidents for commercial or cargo air carriers (Part 121), commuter airlines (Part 135), and general aviation (Part 91). The data was analyzed by Federal Aviation Regulations (FAR) part, phase of flight, SCFM category, human factor category, and a variety of anomalies and results. There were 38 894 SCFM-related incidents and 83 478 human-factorrelated incidents analyzed between January 1993 and April 2011.

  17. Soft systems methodology as a systemic approach to nuclear safety management

    International Nuclear Information System (INIS)

    Vieira Neto, Antonio S.; Guilhen, Sabine N.; Rubin, Gerson A.; Caldeira Filho, Jose S.; Camargo, Iara M.C.

    2017-01-01

    Safety approach currently adopted by nuclear installations is built almost exclusively upon analytical methodologies based, mainly, on the belief that the properties of a system, such as its safety, are given by its constituent parts. This approach, however, does not properly address the complex dynamic interactions between technical, human and organizational factors occurring within and outside the organization. After the accident at Fukushima Daiichi nuclear power plant in March 2011, experts of the International Atomic Energy Agency (IAEA) recommended a systemic approach as a complementary perspective to nuclear safety. The aim of this paper is to present an overview of the systems thinking approach and its potential use for structuring socio technical problems involved in the safety of nuclear installations, highlighting the methodologies related to the soft systems thinking, in particular the Soft Systems Methodology (SSM). The implementation of a systemic approach may thus result in a more holistic picture of the system by the complex dynamic interactions between technical, human and organizational factors. (author)

  18. Soft systems methodology as a systemic approach to nuclear safety management

    Energy Technology Data Exchange (ETDEWEB)

    Vieira Neto, Antonio S.; Guilhen, Sabine N.; Rubin, Gerson A.; Caldeira Filho, Jose S.; Camargo, Iara M.C., E-mail: asvneto@ipen.br, E-mail: snguilhen@ipen.br, E-mail: garubin@ipen.br, E-mail: jscaldeira@ipen.br, E-mail: icamargo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Safety approach currently adopted by nuclear installations is built almost exclusively upon analytical methodologies based, mainly, on the belief that the properties of a system, such as its safety, are given by its constituent parts. This approach, however, does not properly address the complex dynamic interactions between technical, human and organizational factors occurring within and outside the organization. After the accident at Fukushima Daiichi nuclear power plant in March 2011, experts of the International Atomic Energy Agency (IAEA) recommended a systemic approach as a complementary perspective to nuclear safety. The aim of this paper is to present an overview of the systems thinking approach and its potential use for structuring socio technical problems involved in the safety of nuclear installations, highlighting the methodologies related to the soft systems thinking, in particular the Soft Systems Methodology (SSM). The implementation of a systemic approach may thus result in a more holistic picture of the system by the complex dynamic interactions between technical, human and organizational factors. (author)

  19. Spallation Neutron Source Accelerator Facility Target Safety and Non-safety Control Systems

    International Nuclear Information System (INIS)

    Battle, Ronald E.; DeVan, B.; Munro, John K. Jr.

    2006-01-01

    The Spallation Neutron Source (SNS) is a proton accelerator facility that generates neutrons for scientific researchers by spallation of neutrons from a mercury target. The SNS became operational on April 28, 2006, with first beam on target at approximately 200 W. The SNS accelerator, target, and conventional facilities controls are integrated by standardized hardware and software throughout the facility and were designed and fabricated to SNS conventions to ensure compatibility of systems with Experimental Physics Integrated Control System (EPICS). ControlLogix Programmable Logic Controllers (PLCs) interface to instruments and actuators, and EPICS performs the high-level integration of the PLCs such that all operator control can be accomplished from the Central Control room using EPICS graphical screens that pass process variables to and from the PLCs. Three active safety systems were designed to industry standards ISA S84.01 and IEEE 603 to meet the desired reliability for these safety systems. The safety systems protect facility workers and the environment from mercury vapor, mercury radiation, and proton beam radiation. The facility operators operated many of the systems prior to beam on target and developed the operating procedures. The safety and non-safety control systems were tested extensively prior to beam on target. This testing was crucial to identify wiring and software errors and failed components, the result of which was few problems during operation with beam on target. The SNS has continued beam on target since April to increase beam power, check out the scientific instruments, and continue testing the operation of facility subsystems

  20. Safety analysis and evaluation methodology for fusion systems

    International Nuclear Information System (INIS)

    Fujii-e, Y.; Kozawa, Y.; Namba, C.

    1987-03-01

    Fusion systems which are under development as future energy systems have reached a stage that the break even is expected to be realized in the near future. It is desirable to demonstrate that fusion systems are well acceptable to the societal environment. There are three crucial viewpoints to measure the acceptability, that is, technological feasibility, economy and safety. These three points have close interrelation. The safety problem is more important since three large scale tokamaks, JET, TFTR and JT-60, start experiment, and tritium will be introduced into some of them as the fusion fuel. It is desirable to establish a methodology to resolve the safety-related issues in harmony with the technological evolution. The promising fusion system toward reactors is not yet settled. This study has the objective to develop and adequate methodology which promotes the safety design of general fusion systems and to present a basis for proposing the R and D themes and establishing the data base. A framework of the methodology, the understanding and modeling of fusion systems, the principle of ensuring safety, the safety analysis based on the function and the application of the methodology are discussed. As the result of this study, the methodology for the safety analysis and evaluation of fusion systems was developed. New idea and approach were presented in the course of the methodology development. (Kako, I.)

  1. Understanding Nuclear Safety Culture: A Systemic Approach

    International Nuclear Information System (INIS)

    Afghan, A.N.

    2016-01-01

    The Fukushima accident was a systemic failure (Report by Director General IAEA on the Fukushima Daiichi Accident). Systemic failure is a failure at system level unlike the currently understood notion which regards it as the failure of component and equipment. Systemic failures are due to the interdependence, complexity and unpredictability within systems and that is why these systems are called complex adaptive systems (CAS), in which “attractors” play an important role. If we want to understand the systemic failures we need to understand CAS and the role of these attractors. The intent of this paper is to identify some typical attractors (including stakeholders) and their role within complex adaptive system. Attractors can be stakeholders, individuals, processes, rules and regulations, SOPs etc., towards which other agents and individuals are attracted. This paper will try to identify attractors in nuclear safety culture and influence of their assumptions on safety culture behavior by taking examples from nuclear industry in Pakistan. For example, if the nuclear regulator is an attractor within nuclear safety culture CAS then how basic assumptions of nuclear plant operators and shift in-charges about “regulator” affect their own safety behavior?

  2. Restraint of appetite and reduced regional brain volumes in anorexia nervosa: a voxel-based morphometric study

    Directory of Open Access Journals (Sweden)

    Brooks Samantha J

    2011-11-01

    Full Text Available Abstract Background Previous Magnetic Resonance Imaging (MRI studies of people with anorexia nervosa (AN have shown differences in brain structure. This study aimed to provide preliminary extensions of this data by examining how different levels of appetitive restraint impact on brain volume. Methods Voxel based morphometry (VBM, corrected for total intracranial volume, age, BMI, years of education in 14 women with AN (8 RAN and 6 BPAN and 21 women (HC was performed. Correlations between brain volume and dietary restraint were done using Statistical Package for the Social Sciences (SPSS. Results Increased right dorsolateral prefrontal cortex (DLPFC and reduced right anterior insular cortex, bilateral parahippocampal gyrus, left fusiform gyrus, left cerebellum and right posterior cingulate volumes in AN compared to HC. RAN compared to BPAN had reduced left orbitofrontal cortex, right anterior insular cortex, bilateral parahippocampal gyrus and left cerebellum. Age negatively correlated with right DLPFC volume in HC but not in AN; dietary restraint and BMI predicted 57% of variance in right DLPFC volume in AN. Conclusions In AN, brain volume differences were found in appetitive, somatosensory and top-down control brain regions. Differences in regional GMV may be linked to levels of appetitive restraint, but whether they are state or trait is unclear. Nevertheless, these discrete brain volume differences provide candidate brain regions for further structural and functional study in people with eating disorders.

  3. Safety standards of IAEA for management systems

    International Nuclear Information System (INIS)

    Vincze, P.

    2005-01-01

    IAEA has developed a new series of safety standards which are assigned for constitution of the conditions and which give the instruction for setting up the management systems that integrate the aims of safety, health, life environment and quality. The new standard shall replace IAEA 50-C-Q - Requirements for security of the quality for safety in nuclear power plants and other nuclear facilities as well as 14 related safety instructions mentioned in the Safety series No. 50-C/SG-Q (1996). When developing of this complex, integrated set of requirements for management systems, the IAEA requirements 50-C-Q (1996) were taken into consideration as well as the publications developed within the International organisation for standardization (ISO) ISO 9001:2000 and ISO14001: 1996. The experience of European Union member states during the development, implementation and improvement of the management systems were also taken into consideration

  4. Model-based safety architecture framework for complex systems

    NARCIS (Netherlands)

    Schuitemaker, Katja; Rajabali Nejad, Mohammadreza; Braakhuis, J.G.; Podofillini, Luca; Sudret, Bruno; Stojadinovic, Bozidar; Zio, Enrico; Kröger, Wolfgang

    2015-01-01

    The shift to transparency and rising need of the general public for safety, together with the increasing complexity and interdisciplinarity of modern safety-critical Systems of Systems (SoS) have resulted in a Model-Based Safety Architecture Framework (MBSAF) for capturing and sharing architectural

  5. Vehicle license plate recognition based on geometry restraints and multi-feature decision

    Science.gov (United States)

    Wu, Jianwei; Wang, Zongyue

    2005-10-01

    Vehicle license plate (VLP) recognition is of great importance to many traffic applications. Though researchers have paid much attention to VLP recognition there has not been a fully operational VLP recognition system yet for many reasons. This paper discusses a valid and practical method for vehicle license plate recognition based on geometry restraints and multi-feature decision including statistical and structural features. In general, the VLP recognition includes the following steps: the location of VLP, character segmentation, and character recognition. This paper discusses the three steps in detail. The characters of VLP are always declining caused by many factors, which makes it more difficult to recognize the characters of VLP, therefore geometry restraints such as the general ratio of length and width, the adjacent edges being perpendicular are used for incline correction. Image Moment has been proved to be invariant to translation, rotation and scaling therefore image moment is used as one feature for character recognition. Stroke is the basic element for writing and hence taking it as a feature is helpful to character recognition. Finally we take the image moment, the strokes and the numbers of each stroke for each character image and some other structural features and statistical features as the multi-feature to match each character image with sample character images so that each character image can be recognized by BP neural net. The proposed method combines statistical and structural features for VLP recognition, and the result shows its validity and efficiency.

  6. Housing in Pyramid Counteracts Neuroendocrine and Oxidative Stress Caused by Chronic Restraint in Rats

    Directory of Open Access Journals (Sweden)

    M. Surekha Bhat

    2007-01-01

    Full Text Available The space within the great pyramid and its smaller replicas is believed to have an antistress effect. Research has shown that the energy field within the pyramid can protect the hippocampal neurons of mice from stress-induced atrophy and also reduce neuroendocrine stress, oxidative stress and increase antioxidant defence in rats. In this study, we have, for the first time, attempted to study the antistress effects of pyramid exposure on the status of cortisol level, oxidative damage and antioxidant status in rats during chronic restraint stress. Adult female Wistar rats were divided into four groups as follows: normal controls (NC housed in home cage and left in the laboratory; restrained rats (with three subgroups subject to chronic restraint stress by placing in a wire mesh restrainer for 6 h per day for 14 days, the restrained controls (RC having their restrainers kept in the laboratory; restrained pyramid rats (RP being kept in the pyramid; and restrained square box rats (RS in the square box during the period of restraint stress everyday. Erythrocyte malondialdehyde (MDA and plasma cortisol levels were significantly increased and erythrocyte-reduced glutathione (GSH levels, erythrocyte glutathione peroxidase (GSH-Px and superoxide dismutase (SOD activities were significantly decreased in RC and RS rats as compared to NC. However, these parameters were maintained to near normal levels in RP rats which showed significantly decreased erythrocyte MDA and plasma cortisol and significantly increased erythrocyte GSH levels, erythrocyte GSH-Px and SOD activities when compared with RS rats. The results showed that housing in pyramid counteracts neuroendocrine and oxidative stress caused by chronic restraint in rats.

  7. Adrenocortical and behavioural response to chronic restraint stress in neurokinin-1 receptor knockout mice.

    Science.gov (United States)

    Delgado-Morales, Raúl; del Río, Eva; Gómez-Román, Almudena; Bisagno, Verónica; Nadal, Roser; de Felipe, Carmen; Armario, Antonio

    2012-02-01

    Brain substance P and its receptor (neurokinin-1, NK1) have a widespread brain distribution and are involved in an important number of behavioural and physiological responses to emotional stimuli. However, the role of NK1 receptors in the consequences of exposure to chronic stress has not been explored. The present study focused on the role of these receptors in the hypothalamic-pituitary-adrenal (HPA) response to daily repeated restraint stress (evaluated by plasma corticosterone levels), as well as on the effect of this procedure on anxiety-like behaviour, spatial learning and memory in the Morris water maze (MWM), a hippocampus-dependent task. Adult null mutant NK1-/- mice, with a C57BL/6J background, and the corresponding wild-type mice showed similar resting corticosterone levels and, also, did not differ in corticosterone response to a first restraint. Nevertheless, adaptation to the repeated stressor was faster in NK1-/- mice. Chronic restraint modestly increased anxiety-like behaviour in the light-dark test, irrespective of genotype. Throughout the days of the MWM trials, NK1-/- mice showed a similar learning rate to that of wild-type mice, but had lower levels of thigmotaxis and showed a better retention in the probe trial. Chronic restraint stress did not affect these variables in either genotype. These results indicate that deletion of the NK1 receptor does not alter behavioural susceptibility to chronic repeated stress in mice, but accelerates adaptation of the HPA axis. In addition, deletion may result in lower levels of thigmotaxis and improved short-term spatial memory, perhaps reflecting a better learning strategy in the MWM. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. A formal safety analysis for PLC software-based safety critical system using Z

    International Nuclear Information System (INIS)

    Koh, Jung Soo; Seong, Poong Hyun

    1997-01-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formed safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system

  9. Operation safety of complex industrial systems

    International Nuclear Information System (INIS)

    Zwingelstein, G.

    1999-01-01

    Zero fault or zero risk is an unreachable goal in industrial activities like nuclear activities. However, methods and techniques exist to reduce the risks to the lowest possible and acceptable level. The operation safety consists in the recognition, evaluation, prediction, measurement and mastery of technological and human faults. This paper analyses each of these points successively: 1 - evolution of operation safety; 2 - definitions and basic concepts: failure, missions and functions of a system and of its components, basic concepts and operation safety; 3 - forecasting analysis of operation safety: reliability data, data-banks, precautions for the use of experience feedback data; realization of an operation safety study: management of operation safety, quality assurance, critical review and audit of operation safety studies; 6 - conclusions. (J.S.)

  10. eLearning course may shorten the duration of mechanical restraint among psychiatric inpatients: a cluster-randomized trial.

    Science.gov (United States)

    Kontio, Raija; Pitkänen, Anneli; Joffe, Grigori; Katajisto, Jouko; Välimäki, Maritta

    2014-10-01

    The management of psychiatric inpatients exhibiting severely disturbed and aggressive behaviour is an important educational topic. Well structured, IT-based educational programmes (eLearning) often ensure quality and may make training more affordable and accessible. The aim of this study was to explore the impact of an eLearning course for personnel on the rates and duration of seclusion and mechanical restraint among psychiatric inpatients. In a cluster-randomized intervention trial, the nursing personnel on 10 wards were randomly assigned to eLearning (intervention) or training-as-usual (control) groups. The eLearning course comprised six modules with specific topics (legal and ethical issues, behaviour-related factors, therapeutic relationship and self-awareness, teamwork and integrating knowledge with practice) and specific learning methods. The rates (incidents per 1000 occupied bed days) and durations of the coercion incidents were examined before and after the course. A total of 1283 coercion incidents (1143 seclusions [89%] and 140 incidents involving the use of mechanical restraints [11%]) were recorded on the study wards during the data collection period. On the intervention wards, there were no statistically significant changes in the rates of seclusion and mechanical restraint. However, the duration of incidents involving mechanical restraints shortened from 36.0 to 4.0 h (median) (P eLearning course, the duration of incidents involving the use of mechanical restraints decreased. However, more studies are needed to ensure that the content of the course focuses on the most important factors associated with the seclusion-related elements. The eLearning course deserves further development and further studies. The duration of coercion incidents merits attention in future research.

  11. Fecal pellet output does not always correlate with colonic transit in response to restraint stress and corticotropin-releasing factor in rats

    International Nuclear Information System (INIS)

    Nakade, Yukiomi; Mantyh, C.; Pappas, T.N.; Takahashi, Toku

    2007-01-01

    Fecal pellet output has been assessed as a colonic motor activity because of its simplicity. However, it remains unclear whether an acceleration of colonic transit correlates well with an increase in fecal pellet output. We examined the causal relationship between colonic transit and fecal pellet output stimulated by the central application of corticotropin-releasing factor (CRF) and restraint stress. Immediately after intracisternal injection of CRF, 51 Cr was injected via a catheter positioned in the proximal colon. Ninety minutes after 51 Cr injection, the total number of excreted feces was counted, and then the rats were killed. The radioactivity of each colonic segment was evaluated, and the geometric center (GC) of the distribution of 51 Cr was calculated. For the restraint stress study, after administration of 51 Cr into the proximal colon, rats were submitted to wrapping restraint stress for 90 min. Then they were killed, and GC was calculated. Both restraint stress and CRF significantly accelerated colonic transit. There was a positive correlation observed between fecal pellet output and GC of colonic transit in response to restraint stress, but not CRF, when the number of excreted feces was more than three. In contrast, there was no significant correlation observed between the two in stress and CRF when the number of excreted feces was less than two. The acceleration of colonic transit in response to restraint stress and central administration of CRF does not always correlate with an increase in fecal pellet output. (author)

  12. Happy Trails: Transporting Children Safely.

    Science.gov (United States)

    Alexander, Nancy P.

    1995-01-01

    Given that state laws requiring child passenger restraints are often weak or poorly enforced and that misuse of child restraint systems is common among many adults, offers advice for educating parents, children, and caregivers about transportation safety. Discusses the selection and proper use of car seats, and stresses the importance of…

  13. The reliability of nuclear power plant safety systems

    International Nuclear Information System (INIS)

    Susnik, J.

    1978-01-01

    A criterion was established concerning the protection that nuclear power plant (NPP) safety systems should afford. An estimate of the necessary or adequate reliability of the total complex of safety systems was derived. The acceptable unreliability of auxiliary safety systems is given, provided the reliability built into the specific NPP safety systems (ECCS, Containment) is to be fully utilized. A criterion for the acceptable unreliability of safety (sub)systems which occur in minimum cut sets having three or more components of the analysed fault tree was proposed. A set of input MTBF or MTTF values which fulfil all the set criteria and attain the appropriate overall reliability was derived. The sensitivity of results to input reliability data values was estimated. Numerical reliability evaluations were evaluated by the programs POTI, KOMBI and particularly URSULA, the last being based on Vesely's kinetic fault tree theory. (author)

  14. Safety management systems and their role in achieving high standards of operational safety

    International Nuclear Information System (INIS)

    Coulston, D.J.; Baylis, C.C.

    2000-01-01

    Achieving high standards of operational safety requires a robust management framework that is visible to all personnel with responsibility for its implementation. The structure of the management framework must ensure that all processes used to manage safety interlink in a logical and coherent manner, that is, they form a management system that leads to continuous improvement in safety performance. This Paper describes BNFL's safety management system (SMS). The SMS has management processes grouped within 5 main elements: 1. Policy, 2. Organisation, 3. Planning and Implementation, 4. Measuring and Reviewing Performance, 5. Audit. These elements reflect the overall process of setting safety objective (from Policy), measuring success and reviewing the performance. Effective implementation of the SMS requires senior managers to demonstrate leadership through their commitment and accountability. However, the SMS as a whole reflects that every employee at every level within BNFL is responsible for safety of operations under their control. The SMS therefore promotes a proactive safety culture and safe operations. The system is formally documented in the Company's Environmental, Health and Safety (EHS) Manual. Within in BNFL Group, the Company structures enables the Manual to provide overall SMS guidance and co-ordination to its range of nuclear businesses. Each business develops the SMS to be appropriate at all levels of its organisation, but ensuring that each level is consistent with the higher level. The Paper concludes with a summary of BNFL's safety performance. (author)

  15. Safety of huge systems

    International Nuclear Information System (INIS)

    Kondo, Jiro.

    1995-01-01

    Recently accompanying the development of engineering technology, huge systems tend to be constructed. The disaster countermeasures of huge cities become large problems as the concentration of population into cities is conspicuous. To make the expected value of loss small, the knowledge of reliability engineering is applied. In reliability engineering, even if a part of structures fails, the safety as a whole system must be ensured, therefore, the design having margin is carried out. The degree of margin is called redundancy. However, such design concept makes the structure of a system complex, and as the structure is complex, the possibility of causing human errors becomes high. At the time of huge system design, the concept of fail-safe is effective, but simple design must be kept in mind. The accident in Mihama No. 2 plant of Kansai Electric Power Co. and the accident in Chernobyl nuclear power station, and the accident of Boeing B737 airliner and the fatigue breakdown are described. The importance of safety culture was emphasized as the method of preventing human errors. Man-system interface and management system are discussed. (K.I.)

  16. System Safety in an IT Service Organization

    Science.gov (United States)

    Parsons, Mike; Scutt, Simon

    Within Logica UK, over 30 IT service projects are considered safetyrelated. These include operational IT services for airports, railway infrastructure asset management, nationwide radiation monitoring and hospital medical records services. A recent internal audit examined the processes and documents used to manage system safety on these services and made a series of recommendations for improvement. This paper looks at the changes and the challenges to introducing them, especially where the service is provided by multiple units supporting both safety and non-safety related services from multiple locations around the world. The recommendations include improvements to service agreements, improved process definitions, routine safety assessment of changes, enhanced call logging, improved staff competency and training, and increased safety awareness. Progress is reported as of today, together with a road map for implementation of the improvements to the service safety management system. A proposal for service assurance levels (SALs) is discussed as a way forward to cover the wide variety of services and associated safety risks.

  17. Aviation Safety Reporting System: Process and Procedures

    Science.gov (United States)

    Connell, Linda J.

    1997-01-01

    The Aviation Safety Reporting System (ASRS) was established in 1976 under an agreement between the Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA). This cooperative safety program invites pilots, air traffic controllers, flight attendants, maintenance personnel, and others to voluntarily report to NASA any aviation incident or safety hazard. The FAA provides most of the program funding. NASA administers the program, sets its policies in consultation with the FAA and aviation community, and receives the reports submitted to the program. The FAA offers those who use the ASRS program two important reporting guarantees: confidentiality and limited immunity. Reports sent to ASRS are held in strict confidence. More than 350,000 reports have been submitted since the program's beginning without a single reporter's identity being revealed. ASRS removes all personal names and other potentially identifying information before entering reports into its database. This system is a very successful, proof-of-concept for gathering safety data in order to provide timely information about safety issues. The ASRS information is crucial to aviation safety efforts both nationally and internationally. It can be utilized as the first step in safety by providing the direction and content to informed policies, procedures, and research, especially human factors. The ASRS process and procedures will be presented as one model of safety reporting feedback systems.

  18. Developing and maintaining national food safety control systems ...

    African Journals Online (AJOL)

    The establishment of effective food safety systems is pivotal to ensuring the safety of the national food supply as well as food products for regional and international trade. The development, structure and implementation of modern food safety systems have been driven over the years by a number of developments.

  19. COMPRESS - a computerized reactor safety system

    International Nuclear Information System (INIS)

    Vegh, E.

    1986-01-01

    The computerized reactor safety system, called COMPRESS, provides the following services: scram initiation; safety interlockings; event recording. The paper describes the architecture of the system and deals with reliability problems. A self-testing unit checks permanently the correct operation of the independent decision units. Moreover the decision units are tested by short pulses whether they can initiate a scram. The self-testing is described in detail

  20. Nitrogen-system safety study: Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    1982-07-01

    The Department of Energy has primary responsibility for the safety of operations at DOE-owned nuclear facilities. The guidelines for the analysis of credible accidents are outlined in DOE Order 5481.1. DOE has requested that existing plant facilities and operations be reviewed for potential safety problems not covered by standard industrial safety procedures. This review is being conducted by investigating individual facilities and documenting the results in Safety Study Reports which will be compiled to form the Existing Plant Final Safety Analysis Report which is scheduled for completion in September, 1984. This Safety Study documents the review of the Plant Nitrogen System facilities and operations and consists of Section 4.0, Facility and Process Description, and Section 5.0, Accident Analysis, of the Final Safety Analysis Report format. The existing nitrogen system consists of a Superior Air Products Company Type D Nitrogen Plant, nitrogen storage facilities, vaporization facilities and a distribution system. The system is designed to generate and distribute nitrogen gas used in the cascade for seal feed, buffer systems, and for servicing equipment when exceptionally low dew points are required. Gaseous nitrogen is also distributed to various process auxiliary buildings. The average usage is approximately 130,000 standard cubic feet per day

  1. Integrated therapy safety management system.

    Science.gov (United States)

    Podtschaske, Beatrice; Fuchs, Daniela; Friesdorf, Wolfgang

    2013-09-01

    The aim is to demonstrate the benefit of the medico-ergonomic approach for the redesign of clinical work systems. Based on the six layer model, a concept for an 'integrated therapy safety management' is drafted. This concept could serve as a basis to improve resilience. The concept is developed through a concept-based approach. The state of the art of safety and complexity research in human factors and ergonomics forms the basis. The findings are synthesized to a concept for 'integrated therapy safety management'. The concept is applied by way of example for the 'medication process' to demonstrate its practical implementation. The 'integrated therapy safety management' is drafted in accordance with the six layer model. This model supports a detailed description of specific work tasks, the corresponding responsibilities and related workflows at different layers by using the concept of 'bridge managers'. 'Bridge managers' anticipate potential errors and monitor the controlled system continuously. If disruptions or disturbances occur, they respond with corrective actions which ensure that no harm results and they initiate preventive measures for future procedures. The concept demonstrates that in a complex work system, the human factor is the key element and final authority to cope with the residual complexity. The expertise of the 'bridge managers' and the recursive hierarchical structure results in highly adaptive clinical work systems and increases their resilience. The medico-ergonomic approach is a highly promising way of coping with two complexities. It offers a systematic framework for comprehensive analyses of clinical work systems and promotes interdisciplinary collaboration. © 2013 The Authors. British Journal of Clinical Pharmacology © 2013 The British Pharmacological Society.

  2. Integrated therapy safety management system

    Science.gov (United States)

    Podtschaske, Beatrice; Fuchs, Daniela; Friesdorf, Wolfgang

    2013-01-01

    Aims The aim is to demonstrate the benefit of the medico-ergonomic approach for the redesign of clinical work systems. Based on the six layer model, a concept for an ‘integrated therapy safety management’ is drafted. This concept could serve as a basis to improve resilience. Methods The concept is developed through a concept-based approach. The state of the art of safety and complexity research in human factors and ergonomics forms the basis. The findings are synthesized to a concept for ‘integrated therapy safety management’. The concept is applied by way of example for the ‘medication process’ to demonstrate its practical implementation. Results The ‘integrated therapy safety management’ is drafted in accordance with the six layer model. This model supports a detailed description of specific work tasks, the corresponding responsibilities and related workflows at different layers by using the concept of ‘bridge managers’. ‘Bridge managers’ anticipate potential errors and monitor the controlled system continuously. If disruptions or disturbances occur, they respond with corrective actions which ensure that no harm results and they initiate preventive measures for future procedures. The concept demonstrates that in a complex work system, the human factor is the key element and final authority to cope with the residual complexity. The expertise of the ‘bridge managers’ and the recursive hierarchical structure results in highly adaptive clinical work systems and increases their resilience. Conclusions The medico-ergonomic approach is a highly promising way of coping with two complexities. It offers a systematic framework for comprehensive analyses of clinical work systems and promotes interdisciplinary collaboration. PMID:24007448

  3. Reducing Seclusion Timeout and Restraint Procedures with At-Risk Youth

    Science.gov (United States)

    Ryan, Joseph B.; Peterson, Reece; Tetreault, George; Hagen, Emily Vander

    2007-01-01

    The purpose of this pilot study was to review the effects of professional staff training in crisis management and de-escalation techniques on the use of seclusion timeout and restraint procedures with at-risk students in a K-12 special day school. An exploratory pre-post study was conducted over a two-year period, comparing the use of these…

  4. From Safe Systems to Patient Safety

    DEFF Research Database (Denmark)

    Aarts, J.; Nøhr, C.

    2010-01-01

    for the third conference with the theme: The ability to design, implement and evaluate safe, useable and effective systems within complex health care organizations. The theme for this conference was "Designing and Implementing Health IT: from safe systems to patient safety". The contributions have reflected...... and implementation of safe systems and thus contribute to the agenda of patient safety? The contributions demonstrate how the health informatics community has contributed to the performance of significant research and to translating research findings to develop health care delivery and improve patient safety......This volume presents the papers from the fourth International Conference on Information Technology in Health Care: Socio-technical Approaches held in Aalborg, Denmark in June 2010. In 2001 the first conference was held in Rotterdam, The Netherlands with the theme: Sociotechnical' approaches...

  5. Benefits of a systematic approach to maintenance for safety and safety related systems

    International Nuclear Information System (INIS)

    Dam, R.F.; Ayazzudin, S.; Nickerson, J.H.

    2003-01-01

    For safety and safety-related systems, nuclear plants have to balance the requirements of demonstrating the reliability of each system, while maintaining the system and plant availability. With the goal of demonstrating statistical reliability, these systems have extensive testing programs, which often results in system unavailability and this can impact the plant capacity. The inputs to the process are often safety and regulatory related, resulting in programs that provide a high level of scrutiny. In such cases, the value of the application of a Systematic Assessment of Maintenance (SAM) process, such as Reliability Centered Maintenance (RCM), is questioned. The special case of Standby-Safety systems was discussed in a previous paper, where it was demonstrated how SAM techniques provide useful insight into current system performance, the impact of testing on component and system reliability, and how PSA considerations can be integrated into a comprehensive Maintenance, Surveillance, and Inspection (MSI) strategy. Although the system reliability requirements are an important part of the strategy evaluation, SAM techniques provide a systematic assessment within a broader context. Testing is only one part of an overall strategy focused on ensuring that component function is maintained through a combination of monitoring technologies (including testing), predictive techniques, and intrusive maintenance strategies. Each strategy is targeted to known component degradation mechanisms. This thinking can be extended to safety and safety related systems in general. Over the past 6 years, AECL has been working with CANDU utilities in the development and implementation of a comprehensive and integrated Plant Life Management (PLiM) program. As part of developing a comprehensive plant asset management approach, SAM techniques are used to develop a technical basis that not only works towards ensuring reliable operation of plant systems, but also facilitates the optimization and

  6. Declarative Rule-based Safety for Robotic Perception Systems

    DEFF Research Database (Denmark)

    Mogensen, Johann Thor Ingibergsson; Kraft, Dirk; Schultz, Ulrik Pagh

    2017-01-01

    Mobile robots are used across many domains from personal care to agriculture. Working in dynamic open-ended environments puts high constraints on the robot perception system, which is critical for the safety of the system as a whole. To achieve the required safety levels the perception system needs...... to be certified, but no specific standards exist for computer vision systems, and the concept of safe vision systems remains largely unexplored. In this paper we present a novel domain-specific language that allows the programmer to express image quality detection rules for enforcing safety constraints...

  7. Magnetic nuclear core restraint and control

    International Nuclear Information System (INIS)

    Cooper, M.H.

    1979-01-01

    A lateral restraint and control systemm for a nuclear reactor core provides an inherent decrease of core reactivity in response to abnormally high reactor coolant fluid temperatures. An electromagnet is associated with structure for radially compressing the core during normal reactor conditions. A portion of the structures forming a magnetic circuit is composed of ferromagnetic material having a curie temperature corresponding to a selected coolant fluid temperature. Upon a selected signal, or inherently upon a preselected rise in coolant temperature, the magnetic force is decreased by an amount sufficient to relieve the compression force so as to allow core radial expansion. The expanded core configuration provides a decreased reactivity, tending to shut down the nuclear reaction

  8. Field Programmable Gate Array-based I and C Safety System

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Kim, Koh Eun; Kim, Young Geul; Kwon, Jong Soo

    2014-01-01

    Programmable Logic Controller (PLC)-based I and C safety system used in the operating nuclear power plants has the disadvantages of the Common Cause Failure (CCF), high maintenance costs and quick obsolescence, and then it is necessary to develop the other platform to replace the PLC. The Field Programmable Gate Array (FPGA)-based Instrument and Control (I and C) safety system is safer and more economical than Programmable Logic Controller (PLC)-based I and C safety system. Therefore, in the future, FPGA-based I and C safety system will be able to replace the PLC-based I and C safety system in the operating and the new nuclear power plants to get benefited from its safety and economic advantage. FPGA-based I and C safety system shall be implemented and verified by applying the related requirements to perform the safety function

  9. Field Programmable Gate Array-based I and C Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jeong; Kim, Koh Eun; Kim, Young Geul; Kwon, Jong Soo [KEPCO, Daejeon (Korea, Republic of)

    2014-08-15

    Programmable Logic Controller (PLC)-based I and C safety system used in the operating nuclear power plants has the disadvantages of the Common Cause Failure (CCF), high maintenance costs and quick obsolescence, and then it is necessary to develop the other platform to replace the PLC. The Field Programmable Gate Array (FPGA)-based Instrument and Control (I and C) safety system is safer and more economical than Programmable Logic Controller (PLC)-based I and C safety system. Therefore, in the future, FPGA-based I and C safety system will be able to replace the PLC-based I and C safety system in the operating and the new nuclear power plants to get benefited from its safety and economic advantage. FPGA-based I and C safety system shall be implemented and verified by applying the related requirements to perform the safety function.

  10. Operation safety of complex industrial systems. Main concepts

    International Nuclear Information System (INIS)

    Zwingelstein, G.

    2009-01-01

    Operation safety consists in knowing, evaluating, foreseeing, measuring and mastering the technological system and human failures in order to avoid their impacts on health and people's safety, on productivity, and on the environment, and to preserve the Earth's resources. This article recalls the main concepts of operation safety: 1 - evolutions in the domain; 2 - failures, missions and functions of a system and of its components: functional failure, missions and functions, industrial processes, notions of probability; 3 - basic concepts and operation safety: reliability, unreliability, failure density, failure rate, relations between them, availability, maintainability, safety. (J.S.)

  11. Safety assessment of HLW geological disposal system

    International Nuclear Information System (INIS)

    Naito, Morimasa

    2006-01-01

    In accordance with the Japanese nuclear program, the liquid waste with a high level of radioactivity arising from reprocessing is solidified in a stable glass matrix (vitrification) in stainless steel fabrication containers. The vitrified waste is referred to as high-level radioactive waste (HLW), and is characterized by very high initial radioactivity which, even though it decreases with time, presents a potential long-term risk. It is therefore necessary to thoroughly manage HLW from human and his environment. After vitrification, HLW is stored for a period of 30 to 50 years to allow cooling, and finally disposed of in a stable geological environment at depths greater than 300 m below surface. The deep underground environment, in general, is considered to be stable over geological timescales compared with surface environment. By selecting an appropriate disposal site, therefore, it is considered to be feasible to isolate the waste in the repository from man and his environment until such time as radioactivity levels have decayed to insignificance. The concept of geological disposal in Japan is similar to that in other countries, being based on a multibarrier system which combines the natural geological environment with engineered barriers. It should be noted that geological disposal concept is based on a passive safety system that does not require any institutional control for assuring long term environmental safety. To demonstrate feasibility of safe HLW repository concept in Japan, following technical steps are essential. Selection of a geological environment which is sufficiently stable for disposal (site selection). Design and installation of the engineered barrier system in a stable geological environment (engineering measures). Confirmation of the safety of the constructed geological disposal system (safety assessment). For site selection, particular consideration is given to the long-term stability of the geological environment taking into account the fact

  12. 33 CFR 147.847 - Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone.

    Science.gov (United States)

    2010-07-01

    ... Production, Storage, and Offloading System Safety Zone. 147.847 Section 147.847 Navigation and Navigable... ZONES § 147.847 Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone. (a) Description. The BW PIONEER, a Floating Production, Storage and Offloading (FPSO) system, is in...

  13. Parents' Depressive Symptoms and Gun, Fire, and Motor Vehicle Safety Practices.

    Science.gov (United States)

    Morrissey, Taryn W

    2016-04-01

    This study examined associations between mothers' and fathers' depressive symptoms and their parenting practices relating to gun, fire, and motor vehicle safety. Using data from the Early Childhood Longitudinal Study-Birth Cohort (ECLS-B), a nationally representative sample of children birth to age five, linear probability models were used to examine associations between measures of parents' depressive symptoms and their use of firearms, smoke detectors, and motor vehicle restraints. Parents reported use of smoke detectors, motor vehicle restraints, and firearm ownership and storage. Results suggest mothers with moderate or severe depressive symptoms were 2 % points less likely to report that their child always sat in the back seat of the car, and 3 % points less likely to have at least one working smoke detector in the home. Fathers' depressive symptoms were associated with a lower likelihood of both owning a gun and of it being stored locked. Fathers' depressive symptoms amplified associations between mothers' depressive symptoms and owning a gun, such that having both parents exhibit depressive symptoms was associated with an increased likelihood of gun ownership of between 2 and 6 % points. Interventions that identify and treat parental depression early may be effective in promoting appropriate safety behaviors among families with young children.

  14. Finite Element Models Development of Car Seats With Passive Head Restraints to Study Their Meeting Requirements for EURO NCAP

    Directory of Open Access Journals (Sweden)

    D. Yu. Solopov

    2014-01-01

    Full Text Available In performing calculations to evaluate passive safety of car seats by computer modelling methods it is desirable to use the final element models (FEM thereby providing the greatest accuracy of calculation results. Besides, it is expedient to use FEM, which can be calculated by computer for a small period of time to give preliminary results for short terms.The paper describes the features to evaluate a passive safety, which is ensured by the developed KEM of seats with passive head restraints according to requirements of the EURO NCAP.Besides, accuracy of calculated results that is provided by the developed KEM was evaluated. Accuracy evaluation was accomplished in relation to the results obtained the by specialists of the organization conducting similar researches (LSTC.This work was performed within the framework of a technique, which allows us to develop effectively the car seat designs both with passive, and active head restraints, meeting requirements for passive safety.By results of made calculations and experiments it was found that when evaluating by the EURO NCAP technique the "rough" KEM (the 1st and 2nd levels can be considered as rational ones (in terms of labour costs for its creation and problem solving as well as by result errors and it is expedient to use them for preliminary and multivariate calculations. Detailed models (the 3rd level provide the greatest accuracy (the greatest accuracy is reached with the evaluated impact of 16km/h speed under the loading conditions "moderate impact". A relative error of full head acceleration is of 12%.In evaluation by EURO NCAP using NIC criterion a conclusion can be drawn that the seat models of the 2nd level (467 936 KE and the 3rd level (1 255 358 KE meet the passive safety requirements according to EURO NCAP requirements under "light", "moderate", and "heavy" impacts.In evaluation by EURO NCAP for preliminary and multivariate calculations a model of the middle level (consisting of 467

  15. Safety-related instrumentation and control systems for nuclear power plants

    International Nuclear Information System (INIS)

    1984-01-01

    This Safety Guide deals mainly with design requirements for those I and C systems that are important to safety but are not safety systems. The Guide is intended to expand paragraphs 3.1, 3.2 and 3.3 of the Code of Practice on Design for Safety of Nuclear Power Plants (IAEA Safety Series No.50-C-D) in the area of I and C systems important to safety and refers to them as safety-related I and C systems. It also gives guidance and enumerates requirements for multiplexing and the use of the digital computers employed in this area

  16. Evaluating Safety Culture Under the Socio-Technical Complex Systems Perspective

    International Nuclear Information System (INIS)

    Lemos, F. L. de

    2016-01-01

    Since the term “safety culture” was coined, it has gained more and more attention as an effort to achieve higher levels of system safety. A good deal of effort has been done in order to better define, evaluate and implement safety culture programs in organizations throughout all industries, and especially in the Nuclear Industry. Unfortunately, despite all those efforts, we continue to witness accidents that are, in great part, attributed to flaws in the safety culture of the organization. Fukushima nuclear accident is one example of a serious accident in which flaws in the safety culture has been pointed to as one of the main contributors. In general, the definitions of safety culture emphasise the social aspect of the system. While the definitions also include the relations with the technical aspects, it does so in a general sense. For example, the International Nuclear Safety Advisory Group (INSAG) defines safety culture as: “The assembly of characteristics and attitudes in organizations and individuals which establishes that, as an overriding priority, nuclear plant safety issues receives the attention warranted by their significance.” By the way safety culture is defined we can infer that it represents a property of a social system, or a property of the social aspect of the system. In this sense, the social system is a component of the whole system. Where, “system” is understood to be comprised of a social (humans) and technical (equipment) aspects, as a Nuclear Power Plant, for example. Therefore, treating safety culture as an identity on its own right, finding and fixing flaws in the safety culture may not be enough to improve safety of the system. We also needed to evaluate all the interactions between the components that comprise all the aspects of the system. In some cases a flaw in the safety culture can easily be detected, such as an employee not wearing appropriate individual protection equipment, e.g., dosimeter, or when basic safety

  17. Intelligent monitoring-based safety system of massage robot

    Institute of Scientific and Technical Information of China (English)

    胡宁; 李长胜; 王利峰; 胡磊; 徐晓军; 邹雲鹏; 胡玥; 沈晨

    2016-01-01

    As an important attribute of robots, safety is involved in each link of the full life cycle of robots, including the design, manufacturing, operation and maintenance. The present study on robot safety is a systematic project. Traditionally, robot safety is defined as follows: robots should not collide with humans, or robots should not harm humans when they collide. Based on this definition of robot safety, researchers have proposed ex ante and ex post safety standards and safety strategies and used the risk index and risk level as the evaluation indexes for safety methods. A massage robot realizes its massage therapy function through applying a rhythmic force on the massage object. Therefore, the traditional definition of safety, safety strategies, and safety realization methods cannot satisfy the function and safety requirements of massage robots. Based on the descriptions of the environment of massage robots and the tasks of massage robots, the present study analyzes the safety requirements of massage robots; analyzes the potential safety dangers of massage robots using the fault tree tool; proposes an error monitoring-based intelligent safety system for massage robots through monitoring and evaluating potential safety danger states, as well as decision making based on potential safety danger states; and verifies the feasibility of the intelligent safety system through an experiment.

  18. Development and implementation of setpoint tolerances for special safety systems

    International Nuclear Information System (INIS)

    Oliva, A.F.; Balog, G.; Parkinson, D.G.; Archinoff, G.H.

    1991-01-01

    The establishment of tolerances and impairment limits for special safety system setpoints is part of the process whereby the plant operator demonstrates to the regulatory authority that the plant operates safely and within the defined plant licensing envelope. The licensing envelope represents the set of limits and plant operating state and for which acceptably safe plant operation has been demonstrated by the safety analysis. By definition, operation beyond this envelope contributes to overall safety system unavailability. Definition of the licensing envelope is provided in a wide range of documents including the plant operating licence, the safety report, and the plant operating policies and principles documents. As part of the safety analysis, limits are derived for each special safety system initiating parameter such that the relevant safety design objectives are achieved for all design basis events. If initiation on a given parameter occurs at a level beyond its limit, there is a potential reduction in safety system effectiveness relative to the performance credited in the plant safety analysis. These safety system parameter limits, when corrected for random and systematic instrument errors and other errors inherent in the process of periodic testing or calibration, are then used to derive parameter impairment levels and setpoint tolerances. This paper describes the methodology that has evolved at Ontario Hydro for developing and implementing tolerances for special safety system parameters (i.e., the shutdown systems, emergency coolant injection system and containment system). Tolerances for special safety system initiation setpoints are addressed specifically, although many of the considerations discussed here will apply to performance limits for other safety system components. The first part of the paper deals with the approach that has been adopted for defining and establishing setpoint limits and tolerances. The remainder of the paper addresses operational

  19. Ergonomics in the context of system safety

    International Nuclear Information System (INIS)

    Donnelly, K.E.

    1984-01-01

    In a complex industrial environment, ergonomics must be combined with management science and systems analysis to produce a program which can create effective change and improve safety performance. We give an overview of such an approach, namely System Safety, so that its ergonomic content may be seen

  20. Identifying behaviour patterns of construction safety using system archetypes.

    Science.gov (United States)

    Guo, Brian H W; Yiu, Tak Wing; González, Vicente A

    2015-07-01

    Construction safety management involves complex issues (e.g., different trades, multi-organizational project structure, constantly changing work environment, and transient workforce). Systems thinking is widely considered as an effective approach to understanding and managing the complexity. This paper aims to better understand dynamic complexity of construction safety management by exploring archetypes of construction safety. To achieve this, this paper adopted the ground theory method (GTM) and 22 interviews were conducted with participants in various positions (government safety inspector, client, health and safety manager, safety consultant, safety auditor, and safety researcher). Eight archetypes were emerged from the collected data: (1) safety regulations, (2) incentive programs, (3) procurement and safety, (4) safety management in small businesses (5) production and safety, (6) workers' conflicting goals, (7) blame on workers, and (8) reactive and proactive learning. These archetypes capture the interactions between a wide range of factors within various hierarchical levels and subsystems. As a free-standing tool, they advance the understanding of dynamic complexity of construction safety management and provide systemic insights into dealing with the complexity. They also can facilitate system dynamics modelling of construction safety process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Dietary restraint and subjective well-being in university students in Chile

    DEFF Research Database (Denmark)

    Schnettler, Berta; Horacio, Miranda; Sepúlveda, José

    2014-01-01

    with a significant variation in PD, WF, SWLS and SWFL scoring, number of days with mental health problems, frequency of alcoholic drinks consumption, restraint on the consumption of certain foods, drinks and spices, consumption frequency of fruit out of the main meals and types. Typologies did not differ...

  2. Classification of Aeronautics System Health and Safety Documents

    Data.gov (United States)

    National Aeronautics and Space Administration — Most complex aerospace systems have many text reports on safety, maintenance, and associated issues. The Aviation Safety Reporting System (ASRS) spans several...

  3. Survey of electronic safety systems in accelerator applications

    International Nuclear Information System (INIS)

    Mahoney, K.

    1997-01-01

    This paper presents the preliminary results and analysis of a comprehensive survey of the implementation of accelerator safety interlock systems from over 30 international labs. At the present time there is not a self consistent means to evaluate both the experiences and level of protection provided by electronic safety interlock systems. This research is intended to analyze the strength and weaknesses of several different types of interlock system implementation methodologies. Research, medical, and industrial accelerators are compared. Thomas Jefferson National Accelerator Facility (TJNAF) was one of the first large particle accelerators to implement a safety interlock system using programmable logic controllers. Since that time all of the major new U.S. accelerator construction projects plan to use some form of programmable electronics as part of a safety interlock system in some capacity

  4. Environmental Enrichment Blunts Ethanol Consumption after Restraint Stress in C57BL/6 Mice.

    Directory of Open Access Journals (Sweden)

    Priscila Marianno

    Full Text Available Elevated alcohol intake after abstinence is a key feature of the addiction process. Some studies have shown that environmental enrichment (EE affects ethanol intake and other reinforcing effects. However, different EE protocols may vary in their ability to influence alcohol consumption and stress-induced intake. The present study evaluated whether short (3 h or continuous (24 h EE protocols affect ethanol consumption after periods of withdrawal. Mice were challenged with stressful stimuli (24 h isolation and restraint stress to evaluate the effects of stress on drinking. Male C57BL/6 mice were subjected to a two-bottle choice drinking-in-the-dark paradigm for 15 days (20% ethanol and water, 2 h/day, acquisition phase. Control mice were housed under standard conditions (SC. In the first experiment, one group of mice was housed under EE conditions 24 h/day (EE24h. In the second experiment, the exposure to EE was reduced to 3 h/day (EE3h. After the acquisition phase, the animals were deprived of ethanol for 6 days, followed by 2 h ethanol access once a week. Animals were tested in the elevated plus maze (EPM during ethanol withdrawal. During the last 2 weeks, the mice were exposed to 24 h ethanol access. A 1-h restraint stress test was performed immediately before the last ethanol exposure. EE24h but not EE3h increased anxiety-like behavior during withdrawal compared to controls. Neither EE24h nor EE3h affected ethanol consumption during the 2 h weekly exposure periods. However, EE24h and EE3h mice that were exposed to acute restraint stress consumed less ethanol than controls during a 24 h ethanol access. These results showed that EE reduces alcohol intake after an acute restraint stress.

  5. Development and application of digital safety system in NPPs

    International Nuclear Information System (INIS)

    Kwon, Keechoon; Kim, Changhwoi; Lee, Dongyoung

    2012-01-01

    This paper describes the development of digital safety system in NPPs based on safety- grade programmable logic controller (PLC) platform and its application to real NPP construction. The digital safety system consists of a reactor protection system and an engineered safety feature-component control system. The safety-grade PLC platform was developed so that it meets the requirements of the regulation. The PLC consists of various modules such as a power module, a processor module, communication modules, digital input/output modules, analog input/output modules, a LOCA bus extension module, and a high-speed pulse counter module. The reactor protection system is designed with a redundant 4-channel architecture, and every channel is implemented with the same architecture. A single channel consists of a redundant bi-stable processor, a redundant coincidence processor, an automatic test and interface processor, and a cabinet operator module. The engineered safety feature-component control system is designed with four redundant divisions, and implemented with the PLC platform. The principal components of an individual division are fault tolerant group controllers, loop controllers, a test and interface processor, a cabinet operator module and a control channel gateway. The topical report is submitted to the regulatory body, and got safety evaluation report from the regulatory body. Also, the developed system is tested in the integrated performance validation facility. It is decided that the digital safety system applied to Shin-Uljin unit 1 and 2 after a topical report approval and validation test. Design changes occur in the digital safety system that is applied to an actual nuclear power plant construction, and the PLC has also been upgraded

  6. Development and application of digital safety system in NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Keechoon; Kim, Changhwoi; Lee, Dongyoung [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-03-15

    This paper describes the development of digital safety system in NPPs based on safety- grade programmable logic controller (PLC) platform and its application to real NPP construction. The digital safety system consists of a reactor protection system and an engineered safety feature-component control system. The safety-grade PLC platform was developed so that it meets the requirements of the regulation. The PLC consists of various modules such as a power module, a processor module, communication modules, digital input/output modules, analog input/output modules, a LOCA bus extension module, and a high-speed pulse counter module. The reactor protection system is designed with a redundant 4-channel architecture, and every channel is implemented with the same architecture. A single channel consists of a redundant bi-stable processor, a redundant coincidence processor, an automatic test and interface processor, and a cabinet operator module. The engineered safety feature-component control system is designed with four redundant divisions, and implemented with the PLC platform. The principal components of an individual division are fault tolerant group controllers, loop controllers, a test and interface processor, a cabinet operator module and a control channel gateway. The topical report is submitted to the regulatory body, and got safety evaluation report from the regulatory body. Also, the developed system is tested in the integrated performance validation facility. It is decided that the digital safety system applied to Shin-Uljin unit 1 and 2 after a topical report approval and validation test. Design changes occur in the digital safety system that is applied to an actual nuclear power plant construction, and the PLC has also been upgraded.

  7. RSAS: a Reactor Safety Assessment System

    International Nuclear Information System (INIS)

    Sebo, D.E.; Dixon, B.W.; Bray, M.A.

    1985-01-01

    The Reactor Safety Assessment System (RSAS) is an expert system under development for the United States Nuclear Regulatory Commission (NRC). RSAS is being developed for use at the NRC's Operations Center in the event of a serious incident at a licensed nuclear power plant. The system generates situation assessments for the NRC Reactor Safety Team based on a limited number of plant parameters, known operator actions, and plant status data. The RSAS rule base currently covers one reactor type. The extension of the rule base to other reactor types is also discussed

  8. Safety design requirements for safety systems and components of JSFR

    International Nuclear Information System (INIS)

    Kubo, Shigenobu; Shimakawa, Yoshio; Yamano, Hidemasa; Kotake, Shoji

    2011-01-01

    Safety design requirements for JSFR were summarized taking the development targets of the FaCT project and design feature of JSFR into account. The related safety principle and requirements for Monju, CRBRP, PRISM, SPX, LWRs, IAEA standards, goals of GIF, basic principle of INPRO etc. were also taken into account so that the safety design requirements can be a next-generation global standard. The development targets for safety and reliability are set based on those of FaCT, namely, ensuring safety and reliability equal to future LWR and related fuel cycle facilities. In order to achieve these targets, the defence-in-depth concept is used as the basic safety design principle. General features of the safety design requirements are 1) Achievement of higher reliability, 2) Achievement of higher inspectability and maintainability, 3) Introduction of passive safety features, 4) Reduction of operator action needs, 5) Design consideration against Beyond Design Basis Events, 6) In-Vessel Retention of degraded core materials, 7) Prevention and mitigation against sodium chemical reactions, and 8) Design against external events. The current specific requirements for each system and component are summarized taking the basic design concept of JSFR into account, which is an advanced loop-type large-output power plant with a mixed-oxide-fuelled core. (author)

  9. Reliability analysis of diverse safety logic systems of fast breeder reactor

    International Nuclear Information System (INIS)

    Ravi Kumar, Bh.; Apte, P.R.; Srivani, L.; Ilango Sambasivan, S.; Swaminathan, P.

    2006-01-01

    Safety Logic for Fast Breeder Reactor (FBR) is designed to initiate safety action against Design Basis Events. Based on the outputs of various processing circuits, Safety logic system drives the control rods of the shutdown system. So, Safety Logic system is classified as safety critical system. Therefore, reliability analysis has to be performed. This paper discusses the Reliability analysis of Diverse Safety logic systems of FBRs. For this literature survey on safety critical systems, system reliability approach and standards to be followed like IEC-61508 are discussed in detail. For Programmable Logic device based systems, Hardware Description Languages (HDL) are used. So this paper also discusses the Verification and Validation for HDLs. Finally a case study for the Reliability analysis of Safety logic is discussed. (author)

  10. Experimental research progress on passive safety systems of Chinese advanced PWR

    International Nuclear Information System (INIS)

    Xiao Zejun; Zhuo Wenbin; Zheng Hua; Chen Bingde; Zong Guifang; Jia Dounan

    2003-01-01

    TMI and Chernobyl accidents, having pronounced impact on nuclear industries, triggered the governments as well as interested institutions to devote much attention to the safety of nuclear power plant and public's requirements on nuclear power plant safety were also going to be stricter and stricter. It is obvious that safety level of an ordinary light water reactor is no longer satisfactory to these requirements. Recently, the safety authorities have recommended the implementation of passive system to improve the safety of nuclear reactors. Passive safety system is one of the main differences between Chinese advanced PWR and other conventional PWR. The working principle of passive safety system is to utilize the gravity, natural convection (natural circulation) and stored energy to implement the system's safety function. Reactors with passive safety systems are not only safer, but also more economical. The passive safety system of Chinese advanced PWR is composed of three independent systems, i.e. passive containment cooling system, passive residual heat removal system and passive core makeup tank injection system. This paper is a summary of experimental research progress on passive containment cooling system, passive residual heat removal system and passive core makeup tank injection system

  11. A study on LAN applications in nuclear safety systems

    International Nuclear Information System (INIS)

    Kim, Sung; Lee, Young Ryul; Koo, Jun Mo; Han, Jai Bok

    1995-01-01

    It is a general tendency to digitalize the conventional relay based I and C systems in nuclear power plant. But, the digitalisation of nuclear safety systems has many a difficulty to surmount. The typical one thing of many difficulties is the data communication problem between local controllers and systems. The network architecture built with LAN (Local Area Network) in digital systems of the other industries are general. But in case of nuclear safety systems many considerations in point of safety and license are required to implement it in the field. In this parer, some considerations for applying LAN in nuclear safety systems were reviewed

  12. Investigating the influence on safety of retrofitting Italian motorways with barriers meeting a new EU standard.

    Science.gov (United States)

    Cafiso, Salvatore; D'Agostino, Carmelo; Persaud, Bhagwant

    2017-04-03

    A new European Union (EU) regulation for safety barriers, which is based on performance, has encouraged road agencies to perform an upgrade of old barriers, with the expectation that there will be safety benefits at the retrofitted sites. The new class of barriers was designed and installed in compliance with the 1998 (European Norm) EN 1317 standards for road restraint systems, which lays down common requirements for the testing and certification of road restraint systems in all countries of the European Committee for Standardization (CEN). Both the older and new barriers are made of steel and are installed in such a way as to avoid vehicle intrusion, but the older ones are thought to be only effective at low speeds and large angles of impact. The new standard seeks to remedy this by providing better protection at higher speeds. This article seeks to quantify the effect on the frequency of fatal and injury crashes of retrofitting motorways with barriers meeting the new standards. The estimation of the crash modification was carried out by performing an empirical Bayes before-after analysis based on data from the A18 Messina-Catania motorway in Italy. The methodology has the great advantage to account for the regression to the mean effects. Besides, to account for time trend effects and dispersion of crash data, a modified calibration methodology of safety performance was used. This study, based on data collected on 76 km of motorway in the period 2000-2012, derived Crash Modification Factor point estimates that indicate reductions of 72% for run-off-road fatal and injury crashes and 38% in total fatal and injury crashes that could be expected by upgrading an old safety barrier by complying with new EU 1317 standards. The estimated benefit-cost ratio of 5.57 for total crashes indicates that the treatment is cost effective. The magnitude of this benefit indicates that the retrofits are cost-effective even for total crashes and should continue in any European country

  13. Wheelchair tiedown and occupant restraint practices in paratransit vehicles.

    Science.gov (United States)

    Frost, Karen; Bertocci, Gina; Smalley, Craig

    2018-01-01

    The purpose of this study was to characterize wheelchair tiedown and occupant restraint system (WTORS) usage in paratransit vehicles based on observations of wheelchair and scooter (wheeled mobility devices, collectively, "WhMD") passenger trips. A retrospective review of on-board video monitoring recordings of WhMD trips was conducted. Four hundred seventy-five video recordings were collected for review and analysis. The use of all four tiedowns to secure the WhMD was observed more frequently for power WhMDs (82%) and manual WhMDs (80%) compared to scooters (39%), and this difference was significant (pinjuries in this study, misuse and nonuse of WTORS potentially place WhMD seated passengers at higher risk of injury during transit. These findings support the need for improved vehicle operator training and passenger education on the proper use of WTORS and development of WTORS with improved usability and/or alternative technologies that can be automated or used independently.

  14. Research on advanced system safety assessment procedures (4)

    International Nuclear Information System (INIS)

    Suzuki, Kazuhiko; Shimada, Yukiyasu

    2001-03-01

    The past research reports in the area of safety engineering proposed the Computer-aided HAZOP system to be applied to Nuclear Reprocessing Facilities. Automated HAZOP system has great advantage compared with human analysts in terms of accuracy of the results, and time required to conduct HAZOP studies. This report surveys the literature on risk assessment and safety design based on the concept of independent protection layers (IPLs). Furthermore, to improve HAZOP System, tool is proposed to construct the basic model and the internal state model. Such HAZOP system is applied to analyze two kinds of processes, where the ability of the proposed system is verified. In addition, risk assessment support system is proposed to integrate safety design environment and assessment result to be used by other plants as well as to enable the underline plant to use other plants' information. This technique can be implemented using web-based safety information systems. (author)

  15. [Therapeutic restraint and freedom of movement, changing practices].

    Science.gov (United States)

    Perrin-Niquet, Annick

    From confinement to the philosophy of care in the community, the history of psychiatry testifies to the evolution of practices in the matter of the restriction of freedom. The French National Health Authority still too often recommends practices based on restraint. Caregivers, in relation to the clinical aspect of the patients, need clearly identified therapeutic projects. While training can be vital for them, risk management policies can prove to be a hindrance to patients' freedom. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Combined effects of perfluorooctane sulfonate (PFOS) and maternal restraint stress on hypothalamus adrenal axis (HPA) function in the offspring of mice

    International Nuclear Information System (INIS)

    Ribes, Diana; Fuentes, Silvia; Torrente, Margarita; Colomina, M. Teresa; Domingo, Jose L.

    2010-01-01

    Although it is known that prenatal exposure to perfluorooctane sulfonate (PFOS) can cause developmental adverse effects in mammals, the disruptive effects of this compound on hormonal systems are still controversial. Information concerning the effects of PFOS on hypothalamus adrenal (HPA) axis response to stress and corticosterone levels is not currently available. On the other hand, it is well established that stress can enhance the developmental toxicity of some chemicals. In the present study, we assessed the combined effects of maternal restraint stress and PFOS on HPA axis function in the offspring of mice. Twenty plug-positive female mice were divided in two groups. Animals were given by gavage 0 and 6 mg PFOS/kg/day on gestation days 12-18. One half of the animals in each group were also subjected to restraint stress (30 min/session, 3 sessions/day) during the same period. Five plug-positive females were also included as non-manipulated controls. At 3 months of age, activity in an open-field and the stress response were evaluated in male and female mice by exposing them to 30 min of restraint stress. Male and female offspring were subsequently sacrificed and blood samples were collected to measure changes in corticosterone levels at four different moments related to stress exposure conditions: before stress exposure, immediately after 30 min of stress exposure, and recuperation levels at 60 and 90 min after stress exposure. Results indicate corticosterone levels were lower in mice prenatally exposed to restraint. In general terms, PFOS exposure decreased corticosterone levels, although this effect was only significant in females. The recuperation pattern of corticosterone was mainly affected by prenatal stress. Interactive effects between PFOS and maternal stress were sex dependent. The current results suggest that prenatal PFOS exposure induced long-lasting effects in mice.

  17. ABWR (K-6/7) construction experience (computer-based safety system)

    International Nuclear Information System (INIS)

    Yokomura, T.

    1998-01-01

    TEPCO applied a digital safety system to Kashiwazaki-Kariwa Nuclear Power Station Unit Nos. 6 and 7, the world's first ABWR plant. Although this was the first time to apply a digital safety logic system in Japan, we were able to complete construction of K-6/7 very successfully and without any delay. TEPCO took a approach of developing a substantial amount of experience in digital non- safety systems before undertaking the design of the safety protection system. This paper describes the history, techniques and experience behind achieving a highly reliable digital safety system. (author)

  18. SACS2: Dynamic and Formal Safety Analysis Method for Complex Safety Critical System

    International Nuclear Information System (INIS)

    Koh, Kwang Yong; Seong, Poong Hyun

    2009-01-01

    Fault tree analysis (FTA) is one of the most widely used safety analysis technique in the development of safety critical systems. However, over the years, several drawbacks of the conventional FTA have become apparent. One major drawback is that conventional FTA uses only static gates and hence can not capture dynamic behaviors of the complex system precisely. Although several attempts such as dynamic fault tree (DFT), PANDORA, formal fault tree (FFT) and so on, have been made to overcome this problem, they can not still do absolute or actual time modeling because they adapt relative time concept and can capture only sequential behaviors of the system. Second drawback of conventional FTA is its lack of rigorous semantics. Because it is informal in nature, safety analysis results heavily depend on an analyst's ability and are error-prone. Finally reasoning process which is to check whether basic events really cause top events is done manually and hence very labor-intensive and timeconsuming for the complex systems. In this paper, we propose a new safety analysis method for complex safety critical system in qualitative manner. We introduce several temporal gates based on timed computational tree logic (TCTL) which can represent quantitative notion of time. Then, we translate the information of the fault trees into UPPAAL query language and the reasoning process is automatically done by UPPAAL which is the model checker for time critical system

  19. Impact of restraint and disinhibition on PYY plasma levels and subjective feelings of appetite.

    Science.gov (United States)

    Martins, C; Robertson, M D; Morgan, L M

    2010-10-01

    The impact of eating behaviours on circulating levels of appetite-regulating hormones remains largely unknown. The aims of this study were to assess the role of restraint and disinhibition on fasting/postprandial peptide YY (PYY) plasma levels and subjective feelings of appetite in normal-weight individuals and to determine whether the effect was energy load dependent. 33 participants (12 men) were classified as restrained/unrestrained and low/high in disinhibition based on Three Factor Eating Questionnaire-18R and Dutch Eating Behaviour Questionnaire. The impact of restraint/disinhibition on PYY plasma levels and feelings of appetite was measured, after a 500kcal and 1000kcal breakfast, using a randomised crossover design. Restraint did not impact on either fasting or postprandial PYY plasma levels, but participants with high disinhibition had a tendency towards a blunted postprandial PYY response. Moreover, restrained eaters reported lower ratings of prospective food consumption postprandially, and a tendency towards higher fullness/lower hunger. In conclusion, circulating PYY is unaffected by restrained eating behaviour, despite being associated with increased fullness and reduced hunger in the fed state. High levels of disinhibition tend to be associated with a blunted PYY response and this may contribute towards the susceptibility to overconsumption and increased risk of weight gain characteristic of this trait.

  20. The Pattern of Physical Restraints applied to the Mentally-ill in the ...

    African Journals Online (AJOL)

    Diagnostic groups found among the patients included Bipolar Affective Disorder current episode manic with psychotic symptoms (30%), Delirium (25%), Schizophrenia (20%), Acute polymorphic psychotic disorder without symptoms of schizophrenia (20%) and Dementia (5%). The reason for the use of restraints was ...

  1. Analysis of Aviation Safety Reporting System Incident Data Associated With the Technical Challenges of the Vehicle Systems Safety Technology Project

    Science.gov (United States)

    Withrow, Colleen A.; Reveley, Mary S.

    2014-01-01

    This analysis was conducted to support the Vehicle Systems Safety Technology (VSST) Project of the Aviation Safety Program (AVsP) milestone VSST4.2.1.01, "Identification of VSST-Related Trends." In particular, this is a review of incident data from the NASA Aviation Safety Reporting System (ASRS). The following three VSST-related technical challenges (TCs) were the focus of the incidents searched in the ASRS database: (1) Vechicle health assurance, (2) Effective crew-system interactions and decisions in all conditions; and (3) Aircraft loss of control prevention, mitigation, and recovery.

  2. Safety balance: Analysis of safety systems

    International Nuclear Information System (INIS)

    Delage, M.; Giroux, C.

    1990-12-01

    Safety analysis, and particularly analysis of exploitation of NPPs is constantly affected by EDF and by the safety authorities and their methodologies. Periodic safety reports ensure that important issues are not missed on daily basis, that incidents are identified and that relevant actions are undertaken. French safety analysis method consists of three principal steps. First type of safety balance is analyzed at the normal start-up phase for each unit including the final safety report. This enables analysis of behaviour of units ten years after their licensing. Second type is periodic operational safety analysis performed during a few years. Finally, the third step consists of safety analysis of the oldest units with the aim to improve the safety standards. The three steps of safety analysis are described in this presentation in detail with the aim to present the objectives and principles. Examples of most recent exercises are included in order to illustrate the importance of such analyses

  3. Improving safety margin of LWRs by rethinking the emergency core cooling system criteria and safety system capacity

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Youho, E-mail: euo@kaist.ac.kr; Kim, Bokyung, E-mail: bkkim2@kaist.ac.kr; NO, Hee Cheon, E-mail: hcno@kaist.ac.kr

    2016-10-15

    Highlights: • Zircaloy embrittlement criteria can increase to 1370 °C for CP-ECR lower than 13%. • The draft ECCS criteria of U.S. NRC allow less than 5% in power margin. • The Japanese fracture-based criteria allow around 5% in power margin. • Increasing SIT inventory is effective in assuring safety margin for power uprates. - Abstract: This study investigates the engineering compatibility between emergency core cooling system criteria and safety water injection systems, in the pursuit of safety margin increase of light water reactors. This study proposes an acceptable temperature increase to 1370 °C as long as equivalent cladding reacted calculated by the Cathcart–Pawel equation is below 13%, after an extensive literature review. The influence of different ECCS criteria on the safety margin during large break loss of coolant accident is investigated for OPR-1000 by the system code MARS-KS, implemented with the KINS-REM method. The fracture-based emergency core cooling system (ECCS) criteria proposed in this study are shown to enable power margins up to 10%. In the meantime, the draft U.S. NRC’s embrittlement criteria (burnup-sensitive) and Japanese fracture-based criteria are shown to allow less than 5%, and around 5% of power margins, respectively. Increasing safety injection tank (SIT) water inventory is the key, yet convenient, way of assuring safety margin for power increase. More than 20% increase in the SIT water inventory is required to allow 15% power margins, for the U.S. NRC’s burnup-dependent embrittlement criteria. Controlling SIT water inventory would be a useful option that could allow the industrial desire to pursue power margins even under the recent atmosphere of imposing stricter ECCS criteria for the considerable burnup effects.

  4. Real-World Rib Fracture Patterns in Frontal Crashes in Different Restraint Conditions.

    Science.gov (United States)

    Lee, Ellen L; Craig, Matthew; Scarboro, Mark

    2015-01-01

    The purpose of this study was to use the detailed medical injury information in the Crash Injury Research and Engineering Network (CIREN) to evaluate patterns of rib fractures in real-world crash occupants in both belted and unbelted restraint conditions. Fracture patterns binned into rib regional levels were examined to determine normative trends associated with belt use and other possible contributing factors. Front row adult occupants with Abbreviated Injury Scale (AIS) 3+ rib fractures, in frontal crashes with a deployed frontal airbag, were selected from the CIREN database. The circumferential location of each rib fracture (with respect to the sternum) was documented using a previously published method (Ritchie et al. 2006) and digital computed tomography scans. Fracture patterns for different crash and occupant parameters (restraint use, involved physical component, occupant kinematics, crash principal direction of force, and occupant age) were compared qualitatively and quantitatively. There were 158 belted and 44 unbelted occupants included in this study. For belted occupants, fractures were mainly located near the path of the shoulder belt, with the majority of fractures occurring on the inboard (with respect to the vehicle) side of the thorax. For unbelted occupants, fractures were approximately symmetric and distributed across both sides of the thorax. There were negligible differences in fracture patterns between occupants with frontal (0°) and near side (330° to 350° for drivers; 10° to 30° for passengers) crash principal directions of force but substantial differences between groups when occupant kinematics (and contacts within the vehicle) were considered. Age also affected fracture pattern, with fractures tending to occur more anteriorly in older occupants and more laterally in younger occupants (both belted and unbelted). Results of this study confirmed with real-world data that rib fracture patterns in unbelted occupants were more distributed

  5. Integrated environment, safety, and health management system description

    International Nuclear Information System (INIS)

    Zoghbi, J. G.

    2000-01-01

    The Integrated Environment, Safety, and Health Management System Description that is presented in this document describes the approach and management systems used to address integrated safety management within the Richland Environmental Restoration Project

  6. A Nuclear Safety System based on Industrial Computer

    International Nuclear Information System (INIS)

    Kim, Ji Hyeon; Oh, Do Young; Lee, Nam Hoon; Kim, Chang Ho; Kim, Jae Hack

    2011-01-01

    The Plant Protection System(PPS), a nuclear safety Instrumentation and Control (I and C) system for Nuclear Power Plants(NPPs), generates reactor trip on abnormal reactor condition. The Core Protection Calculator System (CPCS) is a safety system that generates and transmits the channel trip signal to the PPS on an abnormal condition. Currently, these systems are designed on the Programmable Logic Controller(PLC) based system and it is necessary to consider a new system platform to adapt simpler system configuration and improved software development process. The CPCS was the first implementation using a micro computer in a nuclear power plant safety protection system in 1980 which have been deployed in Ulchin units 3,4,5,6 and Younggwang units 3,4,5,6. The CPCS software was developed in the Concurrent Micro5 minicomputer using assembly language and embedded into the Concurrent 3205 computer. Following the micro computer based CPCS, PLC based Common-Q platform has been used for the ShinKori/ShinWolsong units 1,2 PPS and CPCS, and the POSAFE-Q PLC platform is used for the ShinUlchin units 1,2 PPS and CPCS. In developing the next generation safety system platform, several factors (e.g., hardware/software reliability, flexibility, licensibility and industrial support) can be considered. This paper suggests an Industrial Computer(IC) based protection system that can be developed with improved flexibility without losing system reliability. The IC based system has the advantage of a simple system configuration with optimized processor boards because of improved processor performance and unlimited interoperability between the target system and development system that use commercial CASE tools. This paper presents the background to selecting the IC based system with a case study design of the CPCS. Eventually, this kind of platform can be used for nuclear power plant safety systems like the PPS, CPCS, Qualified Indication and Alarm . Pami(QIAS-P), and Engineering Safety

  7. A Nuclear Safety System based on Industrial Computer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyeon; Oh, Do Young; Lee, Nam Hoon; Kim, Chang Ho; Kim, Jae Hack [Korea Electric Power Corporation Engineering and Construction, Daejeon (Korea, Republic of)

    2011-05-15

    The Plant Protection System(PPS), a nuclear safety Instrumentation and Control (I and C) system for Nuclear Power Plants(NPPs), generates reactor trip on abnormal reactor condition. The Core Protection Calculator System (CPCS) is a safety system that generates and transmits the channel trip signal to the PPS on an abnormal condition. Currently, these systems are designed on the Programmable Logic Controller(PLC) based system and it is necessary to consider a new system platform to adapt simpler system configuration and improved software development process. The CPCS was the first implementation using a micro computer in a nuclear power plant safety protection system in 1980 which have been deployed in Ulchin units 3,4,5,6 and Younggwang units 3,4,5,6. The CPCS software was developed in the Concurrent Micro5 minicomputer using assembly language and embedded into the Concurrent 3205 computer. Following the micro computer based CPCS, PLC based Common-Q platform has been used for the ShinKori/ShinWolsong units 1,2 PPS and CPCS, and the POSAFE-Q PLC platform is used for the ShinUlchin units 1,2 PPS and CPCS. In developing the next generation safety system platform, several factors (e.g., hardware/software reliability, flexibility, licensibility and industrial support) can be considered. This paper suggests an Industrial Computer(IC) based protection system that can be developed with improved flexibility without losing system reliability. The IC based system has the advantage of a simple system configuration with optimized processor boards because of improved processor performance and unlimited interoperability between the target system and development system that use commercial CASE tools. This paper presents the background to selecting the IC based system with a case study design of the CPCS. Eventually, this kind of platform can be used for nuclear power plant safety systems like the PPS, CPCS, Qualified Indication and Alarm . Pami(QIAS-P), and Engineering Safety

  8. Reliability analysis of Angra I safety systems

    International Nuclear Information System (INIS)

    Oliveira, L.F.S. de; Soto, J.B.; Maciel, C.C.; Gibelli, S.M.O.; Fleming, P.V.; Arrieta, L.A.

    1980-07-01

    An extensive reliability analysis of some safety systems of Angra I, are presented. The fault tree technique, which has been successfully used in most reliability studies of nuclear safety systems performed to date is employed. Results of a quantitative determination of the unvailability of the accumulator and the containment spray injection systems are presented. These results are also compared to those reported in WASH-1400. (E.G.) [pt

  9. Design of the reactor coolant system and associated systems in nuclear power plants. Safety guide

    International Nuclear Information System (INIS)

    2008-01-01

    This Safety Guide was prepared under the IAEA programme for establishing safety standards for nuclear power plants. The basic requirements for the design of safety systems for nuclear power plants are established in the Safety Requirements publication, Safety Standards Series No. NS-R-1 on Safety of Nuclear Power Plants: Design, which it supplements. This Safety Guide describes how the requirements for the design of the reactor coolant system (RCS) and associated systems in nuclear power plants should be met. 1.2. This publication is a revision and combination of two previous Safety Guides, Safety Series No. 50-SG-D6 on Ultimate Heat Sink and Directly Associated Heat Transport Systems for Nuclear Power Plants (1981), and Safety Series No. 50-SG-D13 on Reactor Coolant and Associated Systems in Nuclear Power Plants (1986), which are superseded by this new Safety Guide. 1.3. The revision takes account of developments in the design of the RCS and associated systems in nuclear power plants since the earlier Safety Guides were published in 1981 and 1986, respectively. The other objectives of the revision are to ensure consistency with Ref., issued in 2000, and to update the technical content. In addition, an appendix on pressurized heavy water reactors (PHWRs) has been included

  10. Preliminary investigation on reliability assessment of passive safety system

    International Nuclear Information System (INIS)

    Huang Changfan; Kuang Bo

    2012-01-01

    The reliability evaluation of passive safety system plays an important part in probabilistic safety assessment (PSA) of nuclear power plant applying passive safety design, which depends quantitatively on reliabilities of passive safety system. According to the object of reliability assessment of passive safety system, relevant parameters are identified. Then passive system behavior during accident scenarios are studied. A practical example of this method is given for the case of reliability assessment of AP1000 passive heat removal system in loss of normal feedwater accident. Key and design parameters of PRHRS are identified and functional failure criteria are established. Parameter combinations acquired by Latin hyper~ cube sampling (LHS) in possible parametric ranges are input and calculations of uncertainty propagation through RELAP5/MOD3 code are carried out. Based on the calculations, sensitivity assessment on PRHRS functional criteria and reliability evaluation of the system are presented, which might provide further PSA with PRHR system reliability. (authors)

  11. European methodology of analysis vertical restraints under rule of reason in context of cooperative relation specific investments

    Directory of Open Access Journals (Sweden)

    Agamirova Maria, Е.

    2015-06-01

    Full Text Available The problem of underinvestment in specific assets is a key issue in new institutional economics, especially in case of cooperative relation specific investments. It can be solved due to vertical restraints, as an alternative way of vertical integration to transfer control to partner, who makes relation specific investments. The type of relationspecific investments called «cooperative» investments (or cross investments was nearly absent in economic analysis up to the very end of the twentieth century despite of the fact that such investments are widespread. It led to the absence of analysis relation specific investments in official regulation documents. At the same time, different types of relation specific investments can be characterized by different degree of riskiness and need special regulations of vertical agreements. In the paper author makes an attempt to analyze the European methodology of assessment vertical restraints under rule of reason focusing on the type of relation specific investments. It makes possible to improve analysis of vertical restraint in Russian antitrust.

  12. DESIGN PACKAGE 1E SYSTEM SAFETY ANALYSIS

    Energy Technology Data Exchange (ETDEWEB)

    M. Salem

    1995-06-23

    The purpose of this analysis is to systematically identify and evaluate hazards related to the Yucca Mountain Project Exploratory Studies Facility (ESF) Design Package 1E, Surface Facilities, (for a list of design items included in the package 1E system safety analysis see section 3). This process is an integral part of the systems engineering process; whereby safety is considered during planning, design, testing, and construction. A largely qualitative approach was used since a radiological System Safety Analysis is not required. The risk assessment in this analysis characterizes the accident scenarios associated with the Design Package 1E structures/systems/components(S/S/Cs) in terms of relative risk and includes recommendations for mitigating all identified risks. The priority for recommending and implementing mitigation control features is: (1) Incorporate measures to reduce risks and hazards into the structure/system/component design, (2) add safety devices and capabilities to the designs that reduce risk, (3) provide devices that detect and warn personnel of hazardous conditions, and (4) develop procedures and conduct training to increase worker awareness of potential hazards, on methods to reduce exposure to hazards, and on the actions required to avoid accidents or correct hazardous conditions.

  13. A new concept of safety parameter display system

    International Nuclear Information System (INIS)

    Martinez, A.S.; Oliveira, L.F.S. de; Schirru, R.; Thome Filho, Z.D.; Silva, R.A. da.

    1986-07-01

    A general description of Angra-1 Parameter Display System (SSPA), a real time and on-line computerized monitoring system for the parameters related to the power plant safety is presented. This system has the main purpose of diminish the load on the Angra-1 power plant operators at an emergency event by supplying them with the additional tools serving as the basis for a prompt identification of the accident. The SSPA is a kind of safety parameter display system whose concept was introduced after Three Mile Island accident in USA. The SSPA comprises two nuclear applications independently considered. They are included into the Parameters Monitoring Integrated System (SIMP) and the safety critical function system (SFCS). (Author) [pt

  14. Innovation research on the safety supervision system of nuclear and radiation safety in Jiangsu province

    International Nuclear Information System (INIS)

    Zhang Qihong; Lu Jigen; Zhang Ping; Wang Wanping; Dai Xia

    2012-01-01

    As the rapid development of nuclear technology, the safety supervision of nuclear and radiation becomes very important. The safety radiation frame system should be constructed, the safety super- vision ability for nuclear and radiation should be improved. How to implement effectively above mission should be a new subject of Provincial environmental protection department. Through investigating the innovation of nuclear and radiation supervision system, innovation of mechanism, innovation of capacity, innovation of informatization and so on, the provincial nuclear and radiation safety supervision model is proposed, and the safety framework of nuclear and radiation in Jiangsu is elementally established in the paper. (authors)

  15. Development of the Advanced Nuclear Safety Information Management (ANSIM) System

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Jae Min; Ko, Young Cheol; Song, Tai Gil [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    Korea has become a technically independent nuclear country and has grown into an exporter of nuclear technologies. Thus, nuclear facilities are increasing in significance at KAERI (Korea Atomic Energy Research Institute), and it is time to address the nuclear safety. The importance of nuclear safety cannot be overemphasized. Therefore, a management system is needed urgently to manage the safety of nuclear facilities and to enhance the efficiency of nuclear information. We have established ISP (Information Strategy Planning) for the Integrated Information System of nuclear facility and safety management. The purpose of this paper is to develop a management system for nuclear safety. Therefore, we developed the Advanced Nuclear Safety Information Management system (hereinafter referred to as the 'ANSIM system'). The ANSIM system has been designed and implemented to computerize nuclear safety information for standardization, integration, and sharing in real-time. Figure 1 shows the main home page of the ANSIM system. In this paper, we describe the design requirements, contents, configurations, and utilizations of the ANSIM system

  16. Development of a safety parameter supervision system for Angra-1

    International Nuclear Information System (INIS)

    Silva, R.A. da; Thome Filho, Z.D.; Schirru, R.; Martinez, A.S.; Oliveira, L.F.S. de

    1986-01-01

    The Safety Parameter Supervision System (SSPS) which is a computerized system for monitoring essential parameters in real time, determining the safety status and emergency procedures for returning normal reactor operation, in case of an anomaly occurrence, is presented. The SSPS consists of three sub-systems: Integrated parameter monitoring system which gives to operators an integrated vision of values of a parameter set, able to detect any deviation of normal reactor operation; safety critical function system which evaluates safety status in terms of a safety critical function set appointed in advance, and in case of violation of any critical function, it initiates the adequate emergency procedure to return normal operation; and safety parameter computer system which carries out the arquirement of analogic and digital control signals of nuclear power plant. (M.C.K.) [pt

  17. Constraint - Induced Movement Therapy: Determinants and Correlates of Duration of Adherence to Restraint use Among Stroke Survivors with Hemiparesis

    Directory of Open Access Journals (Sweden)

    Arinola Olasumbo Sanya

    2012-02-01

    Full Text Available Background: Constraint-Induced Movement Therapy (CIMT was developed to improve purposeful movement of the stroke-affected extremity by restrictingthe use of the unaffected extremity. The two main components of CIMT are the training of the more-impaired arm to perform functional tasks, and the restraint of the less-impaired arm. One challenge that the application of CIMT faces is in ensuring adherence to the use of restraint.Purpose: There is a need to determine the factors that may influence adherence, as this would allow CIMT to be delivered more effectively, and prevent situations where unrealistic expectations are placed on stroke–affected individuals.Methods: Thirty stroke survivors with hemiparesis who met the inclusion criteria were consecutively recruited from the physiotherapy out-patient clinics, using a purposive sampling technique. A structured questionnaire was used to obtain information on clinical and socio-demographic parameters. The participants were given a restraint and an adherence time log-book, to make a daily record during the period they wore the restraint. The adherence time logbook was collected at the end of every week of the 3-week study. Motor function and functional use of the upper limb were measured using Motricity Index and Motor Activity Log respectively. Data was analysed using mean and standard deviations, independent t-test and Spearman rho; p was significant at 0.05.Results: Gender (p=0.73 and side affected/handedness (p=0.79 had no significant influence on the percentage duration of adherence to restraint use (DARU. The influence of socio-economic status was seen, with the participants of middle socio-economic status adhering for longer duration (p=0.02. Age had weak and no significant correlation with percentage DARU (p=0.55. There was significantly fair correlation between motor function/functional use at any stage (p=0.55 and the corresponding percentage duration of adherence to restraint use, except

  18. Development of web-based safety review advisory system

    International Nuclear Information System (INIS)

    Kim, M. W.; Lee, H. C.; Park, S. O.; Lee, K. H.; Hur, K. Y.; Lee, S. J.; Choi, S. S.; Kang, C. M.

    2002-01-01

    For the development of an expert system supporting the safety review of nuclear power plants, the application was implemented after gathering necessary theoretical background and practical requirements. The general and the detail functional specifications were established, and they are investigated by KINS (Korea Institute of Nuclear Safety). The Safety Review Advisory System(SRAS), this application on web-server environment was developed according to the above specifications. Reviews can do their safety reviewing regardless of their speciality or reviewing experiences because SRAS is operated by the safety review plans which are converted to standardized format. When the safety reviewing is carried out by using SRAS, the results of safety reviewing are accumulated in the database and may be utilized later usefully, and we can grasp safety reviewing progress. Users of SRAS are categorized into four groups, administrator, project manager, project reviewer and general reviewer. Each user group is delegated appropriate access capability. The function and some screen shots of SRAS are described

  19. Technical features of ABWR safety systems

    International Nuclear Information System (INIS)

    Sugisaki, Toshihiko; Tominaga, Kenji; Horiuchi, Tetsuo

    1986-01-01

    The engineering safety facilities of ABWRs have been disigned so as to have many excellent characteristics such as safety, reliability and economy, reflecting the merit of adopting new technology such as internal pumps and new control rod driving mechanism, and coupled with the safety peculiar to BWRs. In this paper, about ECCS, containment vessels and others which compose the engineering safety facilities of ABWRs, the characteristics related to the safety owing to the adoption of internal pumps and others, and the evaluation of the performance at the time of various accidents are discussed. As the results of safety evaluation, it was clarified that due to the safety peculiar to ABWRs and the characteristics of the safety facilities, the large increases of safety, reliability and economy have been planned in the ABWRs, and for example, core flooding can be maintained even at the time of a hypothetical loss of coolant accident. BWRs have the simple system constitution, good self controllability, large natural circulation ability, simple operation control method and excellent ability of confining heat and radioactivity. BWRs have three safety functions to stop reactors, to remove heat from reactors, and to confine radioactive substances. These functions of ABWRs were evaluated, and very high safety was confirmed. (Kako, I.)

  20. Critical Characteristics of Radiation Detection System Components to be Dedicated for use in Safety Class and Safety Significant System

    International Nuclear Information System (INIS)

    DAVIS, S.J.

    2000-01-01

    This document identifies critical characteristics of components to be dedicated for use in Safety Significant (SS) Systems, Structures, or Components (SSCs). This document identifies the requirements for the components of the common, radiation area, monitor alarm in the WESF pool cell. These are procured as Commercial Grade Items (CGI), with the qualification testing and formal dedication to be performed at the Waste Encapsulation Storage Facility (WESF) for use in safety significant systems. System modifications are to be performed in accordance with the approved design. Components for this change are commercially available and interchangeable with the existing alarm configuration This document focuses on the operational requirements for alarm, declaration of the safety classification, identification of critical characteristics, and interpretation of requirements for procurement. Critical characteristics are identified herein and must be verified, followed by formal dedication, prior to the components being used in safety related applications

  1. Activation of the HPA Axis and Depression of Feeding Behavior Induced by Restraint Stress Are Separately Regulated by PACAPergic Neurotransmission in the Mouse

    OpenAIRE

    Jiang, Sunny Zhihong; Eiden, Lee E.

    2016-01-01

    We measured serum CORT elevation in wild-type and PACAP-deficient C57Bl/6N male mice after acute (1 hr) or prolonged (2–3 hr) daily restraint stress for seven days. The PACAP-dependence of CORT elevation was compared to that of stress-induced hypophagia. Daily restraint induced unhabituated peak CORT elevation, and hypophagia/weight loss, of similar magnitude for 1, 2 and 3 hr of daily restraint, in wild-type mice. Peak CORT elevation, and hypophagia, were both attenuated in PACAP-deficient m...

  2. Acute Restraint Stress Alters Wheel-Running Behavior Immediately Following Stress and up to 20 Hours Later in House Mice.

    Science.gov (United States)

    Malisch, Jessica L; deWolski, Karen; Meek, Thomas H; Acosta, Wendy; Middleton, Kevin M; Crino, Ondi L; Garland, Theodore

    In vertebrates, acute stressors-although short in duration-can influence physiology and behavior over a longer time course, which might have important ramifications under natural conditions. In laboratory rats, for example, acute stress has been shown to increase anxiogenic behaviors for days after a stressor. In this study, we quantified voluntary wheel-running behavior for 22 h following a restraint stress and glucocorticoid levels 24 h postrestraint. We utilized mice from four replicate lines that have been selectively bred for high voluntary wheel-running activity (HR mice) for 60 generations and their nonselected control (C) lines to examine potential interactions between exercise propensity and sensitivity to stress. Following 6 d of wheel access on a 12L∶12D photo cycle (0700-1900 hours, as during the routine selective breeding protocol), 80 mice were physically restrained for 40 min, beginning at 1400 hours, while another 80 were left undisturbed. Relative to unrestrained mice, wheel running increased for both HR and C mice during the first hour postrestraint (P Wheel running was also examined at four distinct phases of the photoperiod. Running in the period of 1600-1840 hours was unaffected by restraint stress and did not differ statistically between HR and C mice. During the period of peak wheel running (1920-0140 hours), restrained mice tended to run fewer revolutions (-11%; two-tailed P = 0.0733), while HR mice ran 473% more than C (P = 0.0008), with no restraint × line type interaction. Wheel running declined for all mice in the latter part of the scotophase (0140-0600 hours), restraint had no statistical effect on wheel running, but HR again ran more than C (+467%; P = 0.0122). Finally, during the start of the photophase (0720-1200 hours), restraint increased running by an average of 53% (P = 0.0443) in both line types, but HR and C mice did not differ statistically. Mice from HR lines had statistically higher plasma corticosterone concentrations

  3. Design of an Active Automotive Safety System

    Directory of Open Access Journals (Sweden)

    Y. Wang

    2013-07-01

    Full Text Available With the development of the national economy, the people's standard of living got corresponding improvement, cars has been one of the indispensable traffic tools in many families. An active safety system is proposed, which can real-time detect the vehicle's running status and judge the security status of the vehicle. The system, which takes single-chip microcomputer as the controlling core and combines with millimeter-wave and ultrasonic distance measurement technology, can detect the distance from vehicle to vehicle and judge the security status of the vehicle. The hardware composition of the system and the data acquiring circuit are proposed, the mathematic model for different situation is established, and the controlling algorithm is completed. This system can accurately measure speed and distance between vehicles; the active safety control system can meet the relevant data measurement and transmission requirement; and can meet the functional requirement of the active safety control system

  4. LOCA analysis of SCWR-M with passive safety system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X.J., E-mail: xiaojingliu@sjtu.edu.cn [School of Nuclear Science and Engineering, Shanghai Jiao Tong University, 800 Dong Chuan Road, Shanghai 200240 (China); Fu, S.W. [Navy University of Engineering, Wuhan, Hubei (China); Xu, Z.H. [Shanghai Nuclear Engineering Research and Design Institute, Shanghai (China); Yang, Y.H. [School of Nuclear Science and Engineering, Shanghai Jiao Tong University, 800 Dong Chuan Road, Shanghai 200240 (China); Cheng, X. [Institute of Fusion and Nuclear Technology, Karlsruhe Institute of Technology (KIT), Kaiserstr. 12, 76131 Karlsruhe (Germany)

    2013-06-15

    Highlights: • Application of the ATHLET-SC code to the trans-critical analysis for SCWR. • Development of a passive safety system for SCWR-M. • Analysis of hot/cold leg LOCA behaviour with different break size. • Introduction of some mitigation measures for SCWR-M -- Abstract: A new SCWR conceptual design (mixed spectrum supercritical water cooled reactor: SCWR-M) is proposed by Shanghai Jiao Tong University (SJTU). R and D activities covering core design, safety system design and code development of SCWR-M are launched at SJTU. Safety system design and analysis is one of the key tasks during the development of SCWR-M. Considering the current advanced reactor design, a new passive safety system for SCWR-M including isolation cooling system (ICS), accumulator injection system (ACC), gravity driven cooling system (GDCS) and automatic depressurization system (ADS) is proposed. Based on the modified and preliminarily assessed system code ATHLET-SC, loss of coolant accident (LOCA) analysis for hot and cold leg is performed in this paper. Three different break sizes are analyzed to clarify the hot and cold LOCA characteristics of the SCWR-M. The influence of the break location and break size on the safety performance of SCWR-M is also concluded. Several measures to induce the core coolant flow and to mitigate core heating up are also discussed. The results achieved so far demonstrate the feasibility of the proposed passive safety system to keep the SCWR-M core at safety condition during loss of coolant accident.

  5. Allopregnanolone's attenuation of the lordosis-inhibiting effects of restraint is blocked by the antiprogestin, CDB-4124.

    Science.gov (United States)

    Uphouse, Lynda; Hiegel, Cindy

    2014-07-01

    A brief restraint experience reduces lordosis behavior in ovariectomized females that have been hormonally primed with estradiol benzoate. The addition of progesterone to the priming prevents the lordosis inhibition. Based on prior studies with an inhibitor of progesterone metabolism, we have implicated the intracellular progesterone receptor, rather than progesterone metabolites, as responsible for this protection. However, the progesterone metabolite, allopregnanolone (3α-hydroxy-5α-pregnan-20-one), also prevents lordosis inhibition after restraint. In a prior study, we reported that the progestin receptor antagonist, RU486 (11β-(4-dimethylamino)phenyl-17β-hydroxy-17-(1-propynyl)estra-4,9-dien-3-one), attenuated the effect of allopregnanolone. Because RU486 can also block the glucocorticoid receptor, in the current studies, we evaluated the effect of the progestin receptor antagonist, CDB-4124 (17α-acetoxy-21-methoxy-11β-[4-N,N-dimethyaminopheny]-19-norpregna-4,9-dione-3,20-dione), which is relatively devoid of antiglucocorticoid activity. Ovariectomized, Fischer rats were injected with 10 μg estradiol benzoate. Two days later, rats received either 60 mg/kg CDB-4124 or 20% DMSO/propylene glycol vehicle 1 h before injection with 4 mg/kg allopregnanolone. After a pretest to confirm sexual receptivity, rats were restrained for 5min and immediately tested for sexual behavior. Lordosis behavior was reduced by the restraint and attenuated by allopregnanolone. Pretreatment with CDB-4124 reduced allopregnanolone's effect. These findings support prior suggestions that allopreganolone reduces the response to restraint by mechanisms that require activation of the intracellular progesterone receptor. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Passive safety systems for integral reactors

    International Nuclear Information System (INIS)

    Kuul, V.S.; Samoilov, O.B.

    1996-01-01

    In this paper, a wide range of passive safety systems intended for use on integral reactors is considered. The operation of these systems relies on natural processes and does not require external power supplies. Using these systems, there is the possibility of preventing serious consequences for all classes of accidents including reactivity, loss-of-coolant and loss of heat sink as well as severe accidents. Enhancement of safety system reliability has been achieved through the use of self-actuating devices, capable of providing passive initiation of protective and isolation systems, which respond immediately to variations in the physical parameters of the fluid in the reactor or in a guard vessel. For beyond design base accidents accompanied by complete loss of heat removal capability, autonomous self-actuated ERHR trains have been proposed. These trains are completely independent of the secondary loops and need no action to isolate them from the steam turbine plant. Passive safety principles have been consistently implemented in AST-500, ATETS-200 and VPBER 600 which are new generation NPPs developed by OKBM. Their main characteristic is enhanced stability over a wide range of internal and external emergency initiators. (author). 10 figs

  7. Passive safety systems for integral reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kuul, V S; Samoilov, O B [OKB Mechanical Engineering (Russian Federation)

    1996-12-01

    In this paper, a wide range of passive safety systems intended for use on integral reactors is considered. The operation of these systems relies on natural processes and does not require external power supplies. Using these systems, there is the possibility of preventing serious consequences for all classes of accidents including reactivity, loss-of-coolant and loss of heat sink as well as severe accidents. Enhancement of safety system reliability has been achieved through the use of self-actuating devices, capable of providing passive initiation of protective and isolation systems, which respond immediately to variations in the physical parameters of the fluid in the reactor or in a guard vessel. For beyond design base accidents accompanied by complete loss of heat removal capability, autonomous self-actuated ERHR trains have been proposed. These trains are completely independent of the secondary loops and need no action to isolate them from the steam turbine plant. Passive safety principles have been consistently implemented in AST-500, ATETS-200 and VPBER 600 which are new generation NPPs developed by OKBM. Their main characteristic is enhanced stability over a wide range of internal and external emergency initiators. (author). 10 figs.

  8. Safety of emerging nuclear energy systems

    International Nuclear Information System (INIS)

    Novikov, V.M.; Slesarev, I.S.

    1989-01-01

    The first stage of world nuclear power development based on light water fission reactors has demonstrated not only rather high rate but at the same time too optimistic attitude to safety problems. Large accidents at Three Mile Island and Chernobyl essentially affects the concept of NP development. As a result the safety and social acceptance of NP became of absolute priority among other problems. That's why emerging nuclear power systems should be first of all estimated from this point of view. In the paper some quantitative criteria of safety derived from estimations of social risk and economic-ecological damage from hypothetical accidents are formulated. On the base of these criteria we define two stages of possible way to meet safety demands: first--development of high safety fission reactors and second--that of asymptotic high safety ENEs. The limits of tolorated expenses for safety are regarded. The basis physical factors determining hazards of NES accidents are considered. This permits to classify the ways of safety demands fulfillment due to physical principals used

  9. Development of Network Protocol for the Integrated Safety System

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. W.; Baek, J. I.; Lee, S. H.; Park, C. S.; Park, K. H.; Shin, J. M. [Hannam Univ., Daejeon (Korea, Republic of)

    2007-06-15

    Communication devices in the safety system of nuclear power plants are distinguished from those developed for commercial purposes in terms of a strict requirement of safety. The concept of safety covers the determinability, the reliability, and the separation/isolation to prevent the undesirable interactions among devices. The safety also requires that these properties be never proof less. Most of the current commercialized communication products rarely have the safety properties. Moreover, they can be neither verified nor validated to satisfy the safety property of implementation process. This research proposes the novel architecture and protocol of a data communication network for the safety system in nuclear power plants.

  10. Development of Network Protocol for the Integrated Safety System

    International Nuclear Information System (INIS)

    Park, S. W.; Baek, J. I.; Lee, S. H.; Park, C. S.; Park, K. H.; Shin, J. M.

    2007-06-01

    Communication devices in the safety system of nuclear power plants are distinguished from those developed for commercial purposes in terms of a strict requirement of safety. The concept of safety covers the determinability, the reliability, and the separation/isolation to prevent the undesirable interactions among devices. The safety also requires that these properties be never proof less. Most of the current commercialized communication products rarely have the safety properties. Moreover, they can be neither verified nor validated to satisfy the safety property of implementation process. This research proposes the novel architecture and protocol of a data communication network for the safety system in nuclear power plants

  11. Identification of competencies for Malaysian occupational safety and health professionals.

    Science.gov (United States)

    Daud, Rabaayah; Ismail, Maimunah; Omar, Zoharah

    2010-01-01

    Competencies of occupational safety and health (OSH) professionals have become a concern due to the significance of safety management in the field of safety engineering. The purpose of this article is to identify competencies needed by OSH professionals. These competencies are required by professionals in administrating and enforcing legislations related to OSH in Malaysia. This study used Delphi technique in three rounds of data collection. The benefits of this research approach are the use of experts in gaining opinions without time and geographical restraints. The results show 25 generic competencies with combinations of cognitive, interpersonal and intrapersonal competencies and 33 functional or specific competencies including knowledge and skills needed by OSH professionals. Both generic and functional competencies are also divided into threshold and differentiating competencies that would be used to differentiate average and excellent performance of OSH professionals.

  12. The passive safety systems of the Swr 1000

    International Nuclear Information System (INIS)

    Neumann, D.

    2001-01-01

    In recent years, a new boiling water reactor (BWR) plant called the SWR 1000 has been developed by Siemens on behalf of Germany's electric utilities. This new plant design concept incorporates the wide range of operating experience gained with German BWRs. The main objective behind developing the SWR 1000 was to design a plant with a rated electric output of approximately 1000 MW which would not only have a lower capital cost and lower power generating costs but would also provide a much higher level of nuclear safety compared to plants currently in operation. This safety-related goal has been met through, for example, the use of passive safety equipment. Passive systems make a significant contribution towards increasing the over-all level of plant safety due to the way in which they operate. They function solely accord-ing to basic laws of nature, such as gravity, and perform their designated functions with-out any need for electric power or other sources of external energy, or signals from instrumentation and control (I and C) equipment. The passive safety systems have been designed such that design basis accidents can be controlled using just these systems alone. However, the design concept of the SWR 1000 is nevertheless still based on the provision of active safety systems in addition to passive systems. (author)

  13. The role of galanin system in modulating depression, anxiety, and addiction-like behaviors after chronic restraint stress.

    Science.gov (United States)

    Zhao, X; Seese, R R; Yun, K; Peng, T; Wang, Z

    2013-08-29

    There is high comorbidity between stress-related psychiatric disorders and addiction, suggesting they may share one or more common neurobiological mechanisms. Because of its role in both depressive and addictive behaviors, the galanin system is a strong candidate for such a mechanism. In this study, we tested if galanin and its receptors are involved in stress-associated behaviors and drug addiction. Mice were exposed to 21 days of chronic restraint stress (CRS); subsequently, mRNA levels of galanin, galanin receptors (GalRs), the rate-limiting enzymes for the synthesis of monoamines, and monoamine autoreceptors were measured in the nucleus accumbens by a quantitative real-time polymerase chain reaction. Moreover, we tested the effects of this stress on morphine-induced addictive behaviors. We found that CRS induced anxiety and depression-like behaviors, impaired the formation and facilitated the extinction process in morphine-induced conditioned place preference (CPP), and also blocked morphine-induced behavioral sensitization. These behavioral results were accompanied by a CRS-dependent increase in the mRNA expression of galanin, GalR1, tyrosine hydroxylase (TH), tryptophan hydroxylase 2, and 5-HT1B receptor. Interestingly, treatment with a commonly used antidepressant, fluoxetine, normalized the CRS-induced behavioral changes based on reversing the higher expression of galanin and TH while increasing the expression of GalR2 and α2A-adrenceptor. These results indicate that activating the galanin system, with corresponding changes to noradrenergic systems, following chronic stress may modulate stress-associated behaviors and opiate addiction. Our findings suggest that galanin and GalRs are worthy of further exploration as potential therapeutic targets to treat stress-related disorders and drug addiction. Copyright © 2013 IBRO. All rights reserved.

  14. Survey of systems safety analysis methods and their application to nuclear waste management systems

    International Nuclear Information System (INIS)

    Pelto, P.J.; Winegardner, W.K.; Gallucci, R.H.V.

    1981-11-01

    This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause-consequence diagrams, G0 methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas for future study

  15. Survey of systems safety analysis methods and their application to nuclear waste management systems

    Energy Technology Data Exchange (ETDEWEB)

    Pelto, P.J.; Winegardner, W.K.; Gallucci, R.H.V.

    1981-11-01

    This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause-consequence diagrams, G0 methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas for future study.

  16. Overview of Risk Mitigation for Safety-Critical Computer-Based Systems

    Science.gov (United States)

    Torres-Pomales, Wilfredo

    2015-01-01

    This report presents a high-level overview of a general strategy to mitigate the risks from threats to safety-critical computer-based systems. In this context, a safety threat is a process or phenomenon that can cause operational safety hazards in the form of computational system failures. This report is intended to provide insight into the safety-risk mitigation problem and the characteristics of potential solutions. The limitations of the general risk mitigation strategy are discussed and some options to overcome these limitations are provided. This work is part of an ongoing effort to enable well-founded assurance of safety-related properties of complex safety-critical computer-based aircraft systems by developing an effective capability to model and reason about the safety implications of system requirements and design.

  17. Simplified safety and containment systems for the iris reactor

    International Nuclear Information System (INIS)

    Conway, L.E.; Lombardi, C.; Ricotti, M.; Oriani, L.

    2001-01-01

    The IRIS (International Reactor Innovative and Secure) is a 100 - 300 MW modular type pressurized water reactor supported by the U.S. DOE NERI Program. IRIS features a long-life core to provide proliferation resistance and to reduce the volume of spent fuel, as well as reduce maintenance requirements. IRIS utilizes an integral reactor vessel that contains all major primary system components. This integral reactor vessel makes it possible to reduce containment size; making the IRIS more cost competitive. IRIS is being designed to enhance reactor safety, and therefore a key aspect of the IRIS program is the development of the safety and containment systems. These systems are being designed to maximize containment integrity, prevent core uncover following postulated accidents, minimize the probability and consequences of severe accidents, and provide a significant simplification over current safety system designs. The design of the IRIS containment and safety systems has been identified and preliminary analyses have been completed. The IRIS safety concept employs some unique features that minimize the consequences of postulated design basis events. This paper will provide a description of the containment design and safety systems, and will summarize the analysis results. (author)

  18. Autonomous system for launch vehicle range safety

    Science.gov (United States)

    Ferrell, Bob; Haley, Sam

    2001-02-01

    The Autonomous Flight Safety System (AFSS) is a launch vehicle subsystem whose ultimate goal is an autonomous capability to assure range safety (people and valuable resources), flight personnel safety, flight assets safety (recovery of valuable vehicles and cargo), and global coverage with a dramatic simplification of range infrastructure. The AFSS is capable of determining current vehicle position and predicting the impact point with respect to flight restriction zones. Additionally, it is able to discern whether or not the launch vehicle is an immediate threat to public safety, and initiate the appropriate range safety response. These features provide for a dramatic cost reduction in range operations and improved reliability of mission success. .

  19. System code improvements for modelling passive safety systems and their validation

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Sebastian; Cron, Daniel von der; Schaffrath, Andreas [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Garching (Germany)

    2016-11-15

    GRS has been developing the system code ATHLET over many years. Because ATHLET, among other codes, is widely used in nuclear licensing and supervisory procedures, it has to represent the current state of science and technology. New reactor concepts such as Generation III+ and IV reactors and SMR are using passive safety systems intensively. The simulation of passive safety systems with the GRS system code ATHLET is still a big challenge, because of non-defined operation points and self-setting operation conditions. Additionally, the driving forces of passive safety systems are smaller and uncertainties of parameters have a larger impact than for active systems. This paper addresses the code validation and qualification work of ATHLET on the example of slightly inclined horizontal heat exchangers, which are e. g. used as emergency condensers (e. g. in the KERENA and the CAREM) or as heat exchanger in the passive auxiliary feed water systems (PAFS) of the APR+.

  20. Aviation Safety Hotline Information System -

    Data.gov (United States)

    Department of Transportation — The Aviation Safety Hotline Information System (ASHIS) collects, stores, and retrieves reports submitted by pilots, mechanics, cabin crew, passengers, or the public...