WorldWideScience

Sample records for safe testing series

  1. Safe affordable fission engine (SAFE 30) module conductivity test thermal model correlation

    International Nuclear Information System (INIS)

    Roman, Jose

    2001-01-01

    The SAFE 30 is a simple, robust space fission power system that is comprised of several independent modules. Each module contains 4 fuel tubes bonded to a central heatpipe. Fission energy is conducted from the fuel tubes to the heatpipe, which in turn transfers the energy to a power conversion system. This paper benchmarks a thermal model of the SAFE 30 with actual test data from simulated SAFE 30 module tests. Two 'dummy' SAFE 30 modules were fabricated - each consisted of 4 1-inch dia. tubes (simulating the fuel tubes) bonded to a central '1' dia. tube (simulating the heatpipe). In the first module the fuel tubes were simply brazed to the heatpipe along the line of contact (leaving void space in the interstices), and in the second module the tubes and heatpipe were brazed via tri-cusps that completely fill the interstices between the tubes. In these tests, fission energy is simulated by placing resistance heaters within each of the 4 fuel tubes. The tests were conducted in a vacuum chamber in 4 configurations: tri-cusps filled with and without an outer insulation wrap, and no tri-cusps with and without an outer insulation wrap. The baseline SAFE 30 configuration uses the brazed tri-cusps. During the tests, the power applied to the heaters was varied in a stepwise fashion, until a steady-state temperature profile was reached. These temperature levels varied between 773 K and 1073 K. To benchmark the thermal model, the input energy and chamber surface temperature were used as boundary conditions for the model. The analytical results from the nodes at the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis by varying the surface emissivity and view factor until a good match was reached. This

  2. Wind pressure testing of tornado safe room components made from wood

    Science.gov (United States)

    Robert Falk; Deepak Shrestha

    2016-01-01

    To evaluate the ability of a wood tornado safe room to resist wind pressures produced by a tornado, two safe room com-ponents were tested for wind pressure strength. A tornado safe room ceiling panel and door were static-pressure-tested according to ASTM E 330 using a vacuum test system. Re-sults indicate that the panels had load capacities from 2.4 to 3.5 times that...

  3. UAS-NAS Flight Test Series 3: Test Environment Report

    Science.gov (United States)

    Hoang, Ty; Murphy, Jim; Otto, Neil

    2016-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration in the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability (SSI), Human Systems Integration (HSI), and Communications (Comm), and Certification to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Detect and Avoid (DAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project is conducting a series of human-in-the-loop (HITL) and flight test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity, and

  4. Classroom Issues with Series Tests

    Science.gov (United States)

    Sadek, Jawad; Euler, Russell

    2005-01-01

    We find infinite series in calculus to be one of the most confusing topics our students encounter. In this note, we look at some issues that our students find difficult or ambiguous involving the Ratio Test, the Root Test, and also the Alternating Series Test. We offer some suggestions and some examples, which could be a supplement to the set of…

  5. Fragrance series testing in eyelid dermatitis.

    Science.gov (United States)

    Wenk, Kurt S; Ehrlich, Alison

    2012-01-01

    Allergic contact dermatitis is considered one of the most common causes of eyelid dermatitis. In addition to metals and topical antibiotics, fragrances have emerged as a leading source of contact allergy for individuals with this condition. The objective of this study was to determine the added benefit of including a fragrance tray when patch testing patients presenting with eyelid dermatitis. During a 4.5-year period, all patients with suspected allergic contact dermatitis involving the eyelids were patch tested with both standard and fragrance trays. One hundred consecutive patients with eyelid dermatitis were patch tested. Of these patients, 42 (42%) tested positive for 1 or more allergens within the fragrance series. Of these patients, 15 (36%) had no fragrance markers detected on the standard series, and these allergens would therefore have been missed had fragrance series testing not been performed. Overall, fragrance markers within the standard series detected 73.2% (41/56) of cases of fragrance allergy. Our results suggest that there may be a significant benefit to fragrance series testing in patients with eyelid dermatitis. Fragrance tray inclusion in this population may identify additional cases of fragrance allergy that are missed by the standard series.

  6. Sodium heat pipe module test for the SAFE-30 reactor prototype

    International Nuclear Information System (INIS)

    Reid, Robert S.; Sena, J. Tom; Martinez, Adam L.

    2001-01-01

    Reliable, long-life, low-cost heat pipes can enable safe, affordable space fission power and propulsion systems. Advanced versions of these systems can in turn allow rapid access to any point in the solar system. Twelve stainless steel-sodium heat pipe modules were built and tested at Los Alamos for use in a non-nuclear thermohydraulic simulation of the SAFE-30 reactor (Poston et al., 2000). SAFE-30 is a near-term, low-cost space fission system demonstration. The heat pipes were designed to remove thermal power from the SAFE-30 core, and transfer this power to an electrical power conversion system. These heat pipe modules were delivered to NASA Marshall Space Flight Center in August 2000 and were assembled and tested in a prototypical configuration during September and October 2000. The construction and test of one of the SAFE-30 modules is described

  7. Embracing Safe Ground Test Facility Operations and Maintenance

    Science.gov (United States)

    Dunn, Steven C.; Green, Donald R.

    2010-01-01

    Conducting integrated operations and maintenance in wind tunnel ground test facilities requires a balance of meeting due dates, efficient operation, responsiveness to the test customer, data quality, effective maintenance (relating to readiness and reliability), and personnel and facility safety. Safety is non-negotiable, so the balance must be an "and" with other requirements and needs. Pressure to deliver services faster at increasing levels of quality in under-maintained facilities is typical. A challenge for management is to balance the "need for speed" with safety and quality. It s especially important to communicate this balance across the organization - workers, with a desire to perform, can be tempted to cut corners on defined processes to increase speed. Having a lean staff can extend the time required for pre-test preparations, so providing a safe work environment for facility personnel and providing good stewardship for expensive National capabilities can be put at risk by one well-intending person using at-risk behavior. This paper documents a specific, though typical, operational environment and cites management and worker safety initiatives and tools used to provide a safe work environment. Results are presented and clearly show that the work environment is a relatively safe one, though still not good enough to keep from preventing injury. So, the journey to a zero injury work environment - both in measured reality and in the minds of each employee - continues. The intent of this paper is to provide a benchmark for others with operational environments and stimulate additional sharing and discussion on having and keeping a safe work environment.

  8. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  9. Test plan for Series 2 spent fuel cladding containment credit tests

    International Nuclear Information System (INIS)

    Wilson, C.N.

    1984-10-01

    This test plan describes a second series of tests to be conducted by Westinghouse Hanford Company (WHC) to evaluate the effectiveness of breached cladding as a barrier to radionuclide release in the NNWSI-proposed geologic repository. These tests will be conducted at the Hanford Engineering Development Laboratory (HEDL). A first series of tests, initiated at HEDL during FY 1983, demonstrated specimen preparation and feasibility of the testing concept. The second series tests will be similar to the Series 1 tests with the following exceptions: NNWSI reference groundwater obtained from well J-13 will be used as the leachant instead of deionized water; fuel from a second source will be used; and certain refinements will be made in specimen preparation, sampling, and analytical procedures. 12 references, 5 figures, 5 tables

  10. Omega test series - an overview

    International Nuclear Information System (INIS)

    Knowles, C.P.

    2001-01-01

    The United States Defense Threat Reduction Agency (DTRA) has supported a series of high explosive calibration experiments that were conducted in the Degelen Mountain area of the Semipalatinsk Test Site (STS) in the Republic of Kazakhstan (ROK). This paper will provide an overview of the second and third tests of this series which have been designated Omega-2 and Omega-3. Omega-2 was conducted on Saturday, September 25, 1999 and Omega-3 on Saturday, July 29, 2000. (author)

  11. Normed algebras and the geometric series test

    Directory of Open Access Journals (Sweden)

    Robert Kantrowitz

    2017-11-01

    Full Text Available The purpose of this article is to survey a class of normed algebras that share many central features of Banach algebras, save for completeness. The likeness of these algebras to Banach algebras derives from the fact that the geometric series test is valid, whereas the lack of completeness points to the failure of the absolute convergence test for series in the algebra. Our main result is a compendium of conditions that are all equivalent to the validity of the geometric series test for commutative unital normed algebras. Several examples in the final section showcase some incomplete normed algebras for which the geometric series test is valid, and still others for which it is not.

  12. Test plan for Series 3 NNWSI spent fuel leaching/dissolution tests

    International Nuclear Information System (INIS)

    Wilson, C.N.

    1986-04-01

    The Series 3 tests will differ from the Series 2 tests in that the Series 3 tests will be run at 85 0 C (J-13 water) in sealed 304 stainless steel (SS) test vessels. The current NNWSI reference spent fuel container material is 304L SS. The candidate NNWSI repository horizon is above the water table, and 95 0 C (boiling temperature at the repository elevation) is the maximum liquid water temperature expected to contact spent fuel in the repository

  13. Multi-frac test series. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R A; Warpinski, N R; Finley, S J; Shear, R C

    1981-11-01

    This paper describes a series of five full-scale tests performed to evaluate various multi-frac concepts. The tests were conducted at the Nevada Test Site in horizontal boreholes drilled in ash-fall tuff from a tunnel under 1300 ft of overburden.

  14. SAFE testing nuclear rockets economically

    International Nuclear Information System (INIS)

    Howe, Steven D.; Travis, Bryan; Zerkle, David K.

    2003-01-01

    Several studies over the past few decades have recognized the need for advanced propulsion to explore the solar system. As early as the 1960s, Werner Von Braun and others recognized the need for a nuclear rocket for sending humans to Mars. The great distances, the intense radiation levels, and the physiological response to zero-gravity all supported the concept of using a nuclear rocket to decrease mission time. These same needs have been recognized in later studies, especially in the Space Exploration Initiative in 1989. One of the key questions that has arisen in later studies, however, is the ability to test a nuclear rocket engine in the current societal environment. Unlike the Rover/NERVA programs in the 1960s, the rocket exhaust can no longer be vented to the open atmosphere. As a consequence, previous studies have examined the feasibility of building a large-scale version of the Nuclear Furnace Scrubber that was demonstrated in 1971. We have investigated an alternative that would deposit the rocket exhaust along with any entrained fission products directly into the ground. The Subsurface Active Filtering of Exhaust, or SAFE, concept would allow variable sized engines to be tested for long times at a modest expense. A system overview, results of preliminary calculations, and cost estimates of proof of concept demonstrations are presented. The results indicate that a nuclear rocket could be tested at the Nevada Test Site for under $20 M

  15. Irradiation effects test Series Scoping Test 1: test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.

    1977-09-01

    The report describes the results of the first scoping test in the Irradiation Effects Test Series conducted by the Thermal Fuels Behavior Program, which is part of the Water Reactor Research Program of EG and G Idaho, Inc. The research is sponsored by the United States Nuclear Regulatory Commission. This test used an unirradiated, three-foot-long, PWR-type fuel rod. The objective of this test was to thoroughly evaluate the remote fabrication procedures to be used for irradiated rods in future tests, handling plans, and reactor operations. Additionally, selected fuel behavior data were obtained. The fuel rod was subjected to a series of preconditioning power cycles followed by a power increase which brought the fuel rod power to about 20.4 kW/ft peak linear heat rating at a coolant mass flux of 1.83 x 10 6 lb/hr-ft 2 . Film boiling occurred for a period of 4.8 minutes following flow reductions to 9.6 x 10 5 and 7.5 x 10 5 lb/hr-ft 2 . The test fuel rod failed following reactor shutdown as a result of heavy internal and external cladding oxidation and embrittlement which occurred during the film boiling operation

  16. Guide to the design, testing and use of packaging for the safe transport of radioactive materials

    International Nuclear Information System (INIS)

    1976-01-01

    This guide gives to designers, manufacturers and users of packaging, advice supplementary to, or in amplification of, the recommendations made by the International Atomic Energy Agency for the safe transport of radioactive materials as given in IAEA Safety Series No. 6 (1973) and the advisory material given in IAEA Safety Series No. 37 (1973). This guide should be read and used in conjunction with these recommendations, the appropriate national regulations and any applicable regulations or requirements of the carriers concerned. (author)

  17. Technical Manual: 2002 Series GED Tests

    Science.gov (United States)

    Ezzelle, Carol; Setzer, J. Carl

    2009-01-01

    This manual was written to provide technical information regarding the 2002 Series GED (General Educational Development) Tests. Throughout this manual, documentation is provided regarding the development of the GED Tests, data collection activities, as well as reliability and validity evidence. The purpose of this manual is to provide evidence…

  18. Operation of multiple superconducting energy doubler magnets in series

    International Nuclear Information System (INIS)

    Kalbfleisch, G.; Limon, P.J.; Rode, C.

    1977-01-01

    In order to understand the operational characteristics of the Energy Doubler, a series of experiments were begun which were designed to be a practical test of running superconducting accelerator magnets in series. Two separate tests in which two Energy Doubler dipoles were powered in series are described. Of particular interest are the static losses of the cryostats and the behavior of the coils and cryostats during quenches. The results of the tests show that Energy Doubler magnets can be safely operated near their short sample limit, and that the various safety devices used are adequate to protect the coils and the cryostats from damage

  19. Testing for intracycle determinism in pseudoperiodic time series.

    Science.gov (United States)

    Coelho, Mara C S; Mendes, Eduardo M A M; Aguirre, Luis A

    2008-06-01

    A determinism test is proposed based on the well-known method of the surrogate data. Assuming predictability to be a signature of determinism, the proposed method checks for intracycle (e.g., short-term) determinism in the pseudoperiodic time series for which standard methods of surrogate analysis do not apply. The approach presented is composed of two steps. First, the data are preprocessed to reduce the effects of seasonal and trend components. Second, standard tests of surrogate analysis can then be used. The determinism test is applied to simulated and experimental pseudoperiodic time series and the results show the applicability of the proposed test.

  20. Air-water tests in support of LLTR series II Test A-4

    International Nuclear Information System (INIS)

    Chen, K.

    1980-07-01

    A series of tests injecting air into a tank of stagnant water was conducted in June 1980 utilizing the GE Plenum Mixing Test Facility in San Jose, California. The test was concerned with investigating the behavior of air jets at a submerged orifice in water over a wide range of flow rates. The main objective was to improve the basic understanding of gas-liquid phenomena (e.g., leak dynamics, gas bubble agglomeration, etc.) in a simulated tube bundle through visualization. The experimental results from these air-water tests will be used as a guide to help select the leak size for LLTR Series II Test A-4 because air-water system is a good simulation of water-sodium mixture

  1. Patch testing with Indian standard series

    Directory of Open Access Journals (Sweden)

    Narendra G

    2002-01-01

    Full Text Available Hundred patients (61 males, 39 females suspected to have allergic contact dermatitis were patch tested with Indian standard series (ISS. Forty four showed one or more positive reactions. The frequent sensitizers observed were nickel sulphate-12 (15%, potassium dichromate-11 (13.75%, cobalt chloride and colophony-7 (8.75% each, fragrance mix and thiuram mix-6 (7.5% each. The ISS differs from the European Standard Series by inclusion of propylene glycol, nitrofurazone, gentamicin, chlorocresol, PEG-400 and ethylenediamine chloride where assesquiterpene lactone mix and primin allergens are excluded.

  2. Test plan for Enraf Series 854 level gauge wire testing

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1994-01-01

    An Enraf Series 854 level gauge was installed on tank 241-S-106 during the first week of June 1994. On August 11, 1994, the gauge's stainless steel measuring wire broke. After examination and laboratory analysis, it was determined that the wire broke due to severe chloride ion corrosion. It is suspected that the chloride ion contamination came from the radiation induced breakdown of the polyvinyl chloride (PVC) riser liner. It is well documented that the breakdown of PVC due to radiation produces chloride containing compounds. This document provides a qualification test plan to remove and have analyzed the wire in all of the Enraf Series 854 that have been installed to date. These tests will confirm the presence or absence of chloride ions in the PVC liners and/or on the Enraf measuring wires installed in the tanks. This test will involve removing the 316 stainless steel wire drums from all of the existing Enraf Series 854 level gauges that have been installed. New 316 stainless steel wire drums shall be installed into the gauges and the gauges will be placed back into service. The wire that is removed from the gauges shall be sent to the 222-S Lab or the Pacific Northwest Laboratory (PNL) for analysis. Additional wire replacements will occur at intervals as determined necessary by the results of the laboratory analyses

  3. Series paralelas al Rorschach: validación en nuestro medio de la serie de Parisi-Pes y del Test de Zulliger Rorschach parallel series: local validation of the Parisi-Pes series and the Z Test

    Directory of Open Access Journals (Sweden)

    Ana María Núñez

    2009-12-01

    Full Text Available El presente artículo surge de la necesidad de validar, en nuestro medio, series paralelas al Test de Rorschach con el fin de poder reemplazarlo en aquellos casos en que se lo requiera. El incremento de la difusión de esta técnica, fuera del ámbito de la comunidad psicológica, puede derivar en un efecto de aprendizaje que dificulte el uso de la herramienta psicodiagnóstica. En esta publicación se realiza un recorrido a través de las diferentes series propuestas como paralelas al Test de Rorschach y se exponen los resultados de dos investigaciones: una de las cuales corresponde a la serie de Parisi-Pes, creada por la Escuela Romana de Rorschach, poco difundida en nuestro medio pero validada en uno con características socioculturales similares al nuestro (Proyecto UBACyT P039; y la otra, el Test de Zulliger, que se aplica con frecuencia en el ámbito laboral, en ambas versiones, individual y colectiva (Proyecto UBACyT P005.This article stems from the need to validate Rorschach parallel series at our social environment, in order to replace it when required. The increase in the dissemination of this technique, outside the psychological community, can lead to a learning effect which may prevent this psychodiagnostic tool from being used. This publication is a journey through the different Rorschach parallel series, and the results from two previous researches are being exposed: the first one of those, belongs to the Parisi-Pes series, created by the Roman Rorschach School, not much locally known but it had been validated in a similar social environment (Project UBACyT P039; the other one, the Z Test, is often used at Labor Psychology in both versions, individual and group administrations (Project UBACyT P005.

  4. Reactivity initiated accident test series Test RIA 1-4 fuel behavior report

    International Nuclear Information System (INIS)

    Cook, B.A.; Martinson, Z.R.

    1984-09-01

    This report presents and discusses results from the final test in the Reactivity Initiated Accident (RIA) Test Series, Test RIA 1-4, conducted in the Power Burst Facility (PBF) at the Idaho National Engineering Laboratory. Nine preirradiated fuel rods in a 3 x 3 bundle configuration were subjected to a power burst while at boiling water reactor hot-startup system conditions. The test resulted in estimated axial peak, radial average fuel enthalpies of 234 cal/g UO 2 on the center rod, 255 cal/g UO 2 on the side rods, and 277 cal/g UO 2 on the corner rods. Test RIA 1-4 was conducted to investigate fuel coolability and channel blockage within a bundle of preirradiated rods near the present enthalpy limit of 280 cal/g UO 2 established by the US Nuclear Regulatory Commission. The test design and conduct are described, and the bundle and individual rod thermal and mechanical responses are evaluated. Conclusions from this final test and the entire PBF RIA Test Series are presented

  5. Irradiation effects test series test IE-1 test results report

    International Nuclear Information System (INIS)

    Quapp, W.J.; Allison, C.M.; Farrar, L.C.; Mehner, A.S.

    1977-03-01

    The report describes the results of the first programmatic test in the Nuclear Regulatory Commission Irradiation Effects Test Series. This test (IE-1) used four 0.97m long PWR-type fuel rods fabricated from previously irradiated Saxton fuel. The objectives of this test were to evaluate the effect of fuel pellet density on pellet-cladding interaction during a power ramp and to evaluate the influence of the irradiated state of the fuel and cladding on rod behavior during film boiling operation. Data are presented on the behavior of irradiated fuel rods during steady-state operation, a power ramp, and film boiling operation. The effects of as-fabricated gap size, as-fabricated fuel density, rod power, and power ramp rate on pellet-cladding interaction are discussed. Test data are compared with FRAP-T2 computer model predictions, and comments on the consequences of sustained film boiling operation on irradiated fuel rod behavior are provided

  6. Phase 1 space fission propulsion system testing and development progress

    International Nuclear Information System (INIS)

    Van Dyke, Melissa; Houts, Mike; Godfroy, Tom; Dickens, Ricky; Poston, David; Kapernick, Rick; Reid, Bob; Salvail, Pat; Ring, Peter

    2002-01-01

    Successful development of space fission systems requires an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through a series of non-nuclear tests. The Safe Affordable Fission Engine (SAFE) test series, whose ultimate goal is the demonstration of a 300 kW flight configuration system, has demonstrated that realistic testing can be performed using non-nuclear methods. This test series, carried out in collaboration with other NASA centers, other government agencies, industry, and universities, successfully completed a testing program with a 30 kWt core. Stirling engine, and ion engine configuration. Additionally, a 100 kWt core is in fabrication and appropriate test facilities are being reconfigured. This paper describes the current SAFE non-nuclear tests, which includes test article descriptions, test results and conclusions, and future test plans

  7. Evaluation of LLTR Series II tests A-1A and A-1B test results

    International Nuclear Information System (INIS)

    Shoopak, B.F.; Amos, J.C.; Norvell, T.J.

    1980-03-01

    The standard methodology, with minor modifications provides conservative yet realistic predictions of leaksite and other sodium system pressures in the LLTR Series II vessel and piping. The good agreement between predicted and measured pressures indicates that the TRANSWRAP/RELAP modeling developed from the Series I tests is applicable to larger scale units prototypical of the Clinch River steam generator design. Calculated sodium system pressures are sensitive to several modeling parameters including rupture disc modeling, acoustic velocity in the test vessel, and flow rate from the rupture tube. The acoustic velocity which produced best agreement with leaksite pressures was calculated based on the shroud diameter and shroud wall thickness. The corresponding rupture tube discharge coefficient was that of the standard design methodology developed from Series I testing. As found in Series I testing, the Series II data suggests that the leading edge of the flow in the relief line is two phase for a single, doubled-ended guillotine tube rupture. The steam generator shroud acts as if it is relatively transparent to the transmission of radial pressures to the vessel wall. Slightly lower sodium system maximum pressures measured during Test A-1b compared to Test A-1a are attributed to premature failure (failure at a lower pressure) of the rupture disc in contact with the sodium for test A-1b. The delay in failure of the second disc in Test A-1b, which was successfully modeled with TRANSWRAP, is attributed to the limited energy in the nitrogen injection

  8. Critical values for unit root tests in seasonal time series

    NARCIS (Netherlands)

    Ph.H.B.F. Franses (Philip Hans); B. Hobijn (Bart)

    1997-01-01

    textabstractIn this paper, we present tables with critical values for a variety of tests for seasonal and non-seasonal unit roots in seasonal time series. We consider (extensions of) the Hylleberg et al. and Osborn et al. test procedures. These extensions concern time series with increasing seasonal

  9. Direct Simple Shear Test Data Analysis using Jupyter Notebooks on DesignSafe-CI

    Science.gov (United States)

    Eslami, M.; Esteva, M.; Brandenberg, S. J.

    2017-12-01

    Due to the large number of files and their complex structure, managing data generated during natural hazards experiments requires scalable and specialized tools. DesignSafe-CI (https://www.designsafe-ci.org/) is a web-based research platform that provides computational tools to analyze, curate, and publish critical data for natural hazards research making it understandable and reusable. We present a use case from a series of Direct Simple Shear (DSS) experiments in which we used DS-CI to post-process, visualize, publish, and enable further analysis of the data. Current practice in geotechnical design against earthquakes relies on the soil's plasticity index (PI) to assess liquefaction susceptibility, and cyclic softening triggering procedures, although, quite divergent recommendations on recommended levels of plasticity can be found in the literature for these purposes. A series of cyclic and monotonic direct simple shear experiments was conducted on three low-plasticity fine-grained mixtures at the same plasticity index to examine the effectiveness of the PI in characterization of these types of materials. Results revealed that plasticity index is an insufficient indicator of the cyclic behavior of low-plasticity fine-grained soils, and corrections for pore fluid chemistry and clay minerology may be necessary for future liquefaction susceptibility and cyclic softening assessment procedures. Each monotonic, or cyclic experiment contains two stages; consolidation and shear, which include time series of load, displacement, and corresponding stresses and strains, as well as equivalent excess pore-water pressure. Using the DS-CI curation pipeline we categorized the data to display and describe the experiment's structure and files corresponding to each stage of the experiments. Two separate notebooks in Python 3 were created using the Jupyter application available in DS-CI. A data plotter aids visualizing the experimental data in relation to the sensor from which it was

  10. Transient testing of the FFTF for decay-heat removal by natural convection

    International Nuclear Information System (INIS)

    Beaver, T.R.; Johnson, H.G.; Stover, R.L.

    1982-06-01

    This paper reports on the series of transient tests performed in the FFTF as a major part of the pre-operations testing program. The structure of the transient test program was designed to verify the capability of the FFTF to safely remove decay heat by natural convection. The series culminated in a scram from full power to complete natural convection in the plant, simulating a loss of all electrical power. Test results and acceptance criteria related to the verification of safe decay heat removal are presented

  11. Fluid flow measurements of Test Series A and B for the Small Scale Seal Performance Tests

    International Nuclear Information System (INIS)

    Peterson, E.W.; Lagus, P.L.; Lie, K.

    1987-12-01

    The degree of waste isolation achieved by a repository seal system is dependent upon the fluid flow characteristics, or permeability, of the seals. In order to obtain meaningful, site-specific data on the performance of various possible seal system components, a series of in situ experiments called the Small Scale Seal Performance Tests (SSSPT) are being conducted at the Waste Isolation Pilot Plant (WIPP). This report contains the results of gas flow, tracer penetration, and brine flow tests conducted on concrete seals in vertical (Test Series A) and horizontal (Test Series B) configurations. The test objectives were to evaluate the seal performance and to determine if there existed scaling effects which could influence future SSSPT designs. 3 refs., 77 figs

  12. Tests for nonlinearity in short stationary time series

    International Nuclear Information System (INIS)

    Chang, T.; Sauer, T.; Schiff, S.J.

    1995-01-01

    To compare direct tests for detecting determinism in chaotic time series, data from Henon, Lorenz, and Mackey--Glass equations were contaminated with various levels of additive colored noise. These data were analyzed with a variety of recently developed tests for determinism, and the results compared

  13. Bootstrap Power of Time Series Goodness of fit tests

    Directory of Open Access Journals (Sweden)

    Sohail Chand

    2013-10-01

    Full Text Available In this article, we looked at power of various versions of Box and Pierce statistic and Cramer von Mises test. An extensive simulation study has been conducted to compare the power of these tests. Algorithms have been provided for the power calculations and comparison has also been made between the semi parametric bootstrap methods used for time series. Results show that Box-Pierce statistic and its various versions have good power against linear time series models but poor power against non linear models while situation reverses for Cramer von Mises test. Moreover, we found that dynamic bootstrap method is better than xed design bootstrap method.

  14. Power-Cooling-Mismatch Test Series Test PCM-7. Experiment operating specifications

    International Nuclear Information System (INIS)

    Sparks, D.T.; Smith, R.H.; Stanley, C.J.

    1979-02-01

    The experiment operating specifications for the Power-Cooling-Mismatch (PCM) Test PCM-7 to be conducted in the Power Burst Facility are described. The PCM Test Series was designed on the basis of a parametric evaluation of fuel behavior response with cladding temperature, rod internal pressure, time in film boiling, and test rod power being the variable parameters. The test matrix, defined in the PCM Experiment Requirements Document (ERD), encompasses a wide range of situations extending from pre-CHF (critical heat flux) PCMs to long duration operation in stable film boiling leading to rod failure

  15. ACER Mathematics Profile Series: Number Test. (Test Booklet, Answer and Record Sheet, Score Key, and Teachers Handbook).

    Science.gov (United States)

    Cornish, Greg; Wines, Robin

    The Number Test of the ACER Mathematics Profile Series, contains 30 items, for each of three suggested grade levels: 7-8, 8-9, and 9-10. Raw scores on all tests in the ACER Mathematics Profile Series (Number, Operations, Space and Measurement) are converted to a common scale called MAPS, a major feature of the Series. Based on the Rasch Model,…

  16. Heat Pipe Reactor Dynamic Response Tests: SAFE-100 Reactor Core Prototype

    Science.gov (United States)

    Bragg-Sitton, Shannon M.

    2005-01-01

    The SAFE-I00a test article at the NASA Marshall Space Flight Center was used to simulate a variety of potential reactor transients; the SAFEl00a is a resistively heated, stainless-steel heat-pipe (HP)-reactor core segment, coupled to a gas-flow heat exchanger (HX). For these transients the core power was controlled by a point kinetics model with reactivity feedback based on core average temperature; the neutron generation time and the temperature feedback coefficient are provided as model inputs. This type of non-nuclear test is expected to provide reasonable approximation of reactor transient behavior because reactivity feedback is very simple in a compact fast reactor (simple, negative, and relatively monotonic temperature feedback, caused mostly by thermal expansion) and calculations show there are no significant reactivity effects associated with fluid in the HP (the worth of the entire inventory of Na in the core is .tests, the point kinetics model was based on core thermal expansion via deflection measurements. It was found that core deflection was a strung function of how the SAFE-100 modules were fabricated and assembled (in terms of straightness, gaps, and other tolerances). To remove the added variable of how this particular core expands as compared to a different concept, it was decided to use a temperature based feedback model (based on several thermocouples placed throughout the core).

  17. New significance test methods for Fourier analysis of geophysical time series

    Directory of Open Access Journals (Sweden)

    Z. Zhang

    2011-09-01

    Full Text Available When one applies the discrete Fourier transform to analyze finite-length time series, discontinuities at the data boundaries will distort its Fourier power spectrum. In this paper, based on a rigid statistics framework, we present a new significance test method which can extract the intrinsic feature of a geophysical time series very well. We show the difference in significance level compared with traditional Fourier tests by analyzing the Arctic Oscillation (AO and the Nino3.4 time series. In the AO, we find significant peaks at about 2.8, 4.3, and 5.7 yr periods and in Nino3.4 at about 12 yr period in tests against red noise. These peaks are not significant in traditional tests.

  18. Development of a tornado safe room door from wood Products: door design and impact testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell

    2016-01-01

    In this study, a tornado safe room door built from wood products and steel sheeting was developed and impact-tested according to tornado safe room standards. Results indicate that an door constructed from as few as two sheets of 23/32-in. (18.26-mm) construction-grade plywood and overlaid with 18-gauge (0.05-in.- (1.27- mm-) thick) steel can pass the required impact...

  19. FLECHT low flooding rate skewed test series data report

    International Nuclear Information System (INIS)

    Rosal, E.R.; Conway, C.E.; Krepinevich, M.C.

    1977-05-01

    The FLECHT Low Flooding Rate Tests were conducted in an improved original FLECHT Test Facility to provide heat transfer coefficient and entrainment data at forced flooding rates of 1 in./sec. and with electrically heated rod bundles which had cosine and top skewed axial power profiles. The top-skewed axial power profile test series has now been successfully completed and is here reported. For these tests the rod bundle was enclosed in a low mass cylindrical housing which would minimize the wall housing effects encountered in the cosine test series. These tests examined the effects of initial clad temperature, variable stepped and continuously variable flooding rates, housing heat release, rod peak power, constant low flooding rates, coolant subcooling, hot and cold channel entrainment, and bundle stored and generated power. Data obtained in runs which met the test specifications are reported here, and include rod clad temperatures, turn around and quench times, heat transfer coefficients, inlet flooding rates, overall mass balances, differential pressures and calculated void fractions in the test section, thimble wall and steam temperatures, and exhaust steam and liquid carryover rates

  20. Aircraft control surface failure detection and isolation using the OSGLR test. [orthogonal series generalized likelihood ratio

    Science.gov (United States)

    Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.

    1986-01-01

    The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.

  1. Test plan for Enraf Series 854 level gauge testing in Tank 241-S-106

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1994-01-01

    An Enraf Series 854 level gauge was installed on Tank 241-S-106 (S-106) during the first week of June 1994. On August 11, 1994, the gauge's measuring wire broke. An investigation has been started to determine how the wire broke. This test plan identifies a qualification test that is part of this investigation. This test will also provide evidence as to the location and extent of potential corrosion on the measuring wire due to tank environment. The results from this testing will provide data for better material selections. This test will involve placing the existing Enraf Series 854 level gauge back into service with the same type of measuring wire (316 stainless steel) that originally broke on August 11, 1994. The gauge will be operated for 14 days. At the end of the 14-day test, the wire shall be sent to Pacific Northwest Laboratory (PNL) for analysis

  2. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  3. SPE5 Sub-Scale Test Series Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Vandersall, Kevin S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reeves, Robert V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); DeHaven, Martin R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Strickland, Shawn L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-01-14

    A series of 2 SPE5 sub-scale tests were performed to experimentally confirm that a booster system designed and evaluated in prior tests would properly initiate the PBXN-110 case charge fill. To conduct the experiments, a canister was designed to contain the nominally 50 mm diameter booster tube with an outer fill of approximately 150 mm diameter by 150 mm in length. The canisters were filled with PBXN-110 at NAWS-China Lake and shipped back to LLNL for testing in the High Explosives Applications Facility (HEAF). Piezoelectric crystal pins were placed on the outside of the booster tube before filling, and a series of piezoelectric crystal pins along with Photonic Doppler Velocimetry (PDV) probes were placed on the outer surface of the canister to measure the relative timing and magnitude of the detonation. The 2 piezoelectric crystal pins integral to the booster design were also utilized along with a series of either piezoelectric crystal pins or piezoelectric polymer pads on the top of the canister or outside case that utilized direct contact, gaps, or different thicknesses of RTV cushions to obtain time of arrival data to evaluate the response in preparation for the large-scale SPE5 test. To further quantify the margin of the booster operation, the 1st test (SPE5SS1) was functioned with both detonators and the 2nd test (SPE5SS2) was functioned with only 1 detonator. A full detonation of the material was observed in both experiments as observed by the pin timing and PDV signals. The piezoelectric pads were found to provide a greater measured signal magnitude during the testing with an RTV layer present, and the improved response is due to the larger measurement surface area of the pad. This report will detail the experiment design, canister assembly for filling, final assembly, experiment firing, presentation of the diagnostic results, and a discussion of the results.

  4. Science Library of Test Items. Volume Nine. Mastery Testing Programme. [Mastery Tests Series 1.] Tests M1-M13.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of the first 13 tests are provided. Skills to be tested include: (1) reading a table; (2) using a biological key; (3) identifying chemical symbols; (4) identifying parts of a human body; (5) reading a line graph; (6) identifying electronic and…

  5. Patch testing with hair cosmetic series in Europe

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Bensefa-Colas, Lynda; Frosch, Peter

    2015-01-01

    Many key ingredients of hair cosmetics (in particular, dyes, bleaches, and hair-styling agents) are potent (strong to extreme) contact allergens. Some heterogeneity is apparent from published results concerning the range of allergens for which patch testing is important. The objective...... of the present review was to collect information on the current practice of using 'hair cosmetic series', and discuss this against the background of evidence concerning consumer/professional exposure and regulatory aspects to finally derive a recommendation for a 'European hair cosmetic series'. The methods...... (Annex II of the Cosmetics Regulation). An up-to-date 'European hair cosmetics series', as recommended in the present article, should (i) include broadly used and/or potent contact allergens, (ii) eliminate substances of only historical concern, and (iii) be continually updated as new evidence emerges....

  6. A Cryogenic Test Set-Up for the Qualification of Pre-Series Test Cells for the LHC Cryogenic Distribution Line

    CERN Document Server

    Livran, J; Parente, C; Riddone, G; Rybkowski, D; Veillet, N

    2000-01-01

    Three pre-series Test Cells of the LHC Cryogenic Distribution Line (QRL) [1], manufactured by three European industrial companies, will be tested in the year 2000 to qualify the design chosen and verify the thermal and mechanical performances. A dedicated test stand (170 m x 13 m) has been built for extensive testing and performance assessment of the pre-series units in parallel. They will be fed with saturated liquid helium at 4.2 K supplied by a mobile helium dewar. In addition, LN2 cooled helium will be used for cool-down and thermal shielding. For each of the three pre-series units, a set of end boxes has been designed and manufactured at CERN. This paper presents the layout of the cryogenic system for the pre-series units, the calorimetric methods as well as the results of the thermal calculation of the end box test.

  7. Science Library of Test Items. Volume Eleven. Mastery Testing Programme. [Mastery Tests Series 3.] Tests M27-M38.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 27 through 38 include: (27) reading a grid plan; (28) identifying common invertebrates; (29) characteristics of invertebrates; (30) identifying elements; (31) using scientific notation part I; (32) classifying minerals; (33) predicting the…

  8. Enraf Series 854 advanced technology gauge (ATG) acceptance test procedure

    International Nuclear Information System (INIS)

    Huber, J.H.

    1996-01-01

    This Acceptance Test Procedure was written to test the Enraf Series 854 Advanced Technology Gauge (ATG) prior to installation in the Tank Farms. The procedure sets various parameters and verifies that the gauge is functional

  9. Science Library of Test Items. Volume Ten. Mastery Testing Programme. [Mastery Tests Series 2.] Tests M14-M26.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 14 through 26 include: (14) calculating an average; (15) identifying parts of the scientific method; (16) reading a geological map; (17) identifying elements, mixtures and compounds; (18) using Ohm's law in calculation; (19) interpreting…

  10. Assessment Guide for Educators: A Content Comparison--2002 Series Test and the Current GED® Test

    Science.gov (United States)

    GED Testing Service, 2017

    2017-01-01

    This report provides a content comparison for the 2002 Series GED® test and the current GED® for the following test topic areas: (1) Mathematical Reasoning; (2) Reasoning through Language Arts; (3) Science; and (4) Social Studies.

  11. Science Library of Test Items. Volume Thirteen. Mastery Testing Program. [Mastery Tests Series 5.] Tests M51-M65.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 51 through 65 include: (51) interpreting atomic and mass numbers; (52) extrapolating from a geological map; (53) matching geological sections and maps; (54) identifying parts of the human eye; (55) identifying the functions of parts of a…

  12. Multiple (Two) Met Bel 601 In Series Ultimate Vacuum Testing

    Energy Technology Data Exchange (ETDEWEB)

    Restivo, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-30

    SRNL Environmental and Chemical Process Technology (E&CPT) was requested to perform testing of vacuum pumps per a verbal request from the Customer, SRNL Hydrogen Processing Technology. Tritium Operations is currently having difficulties procuring the Normetex™® Model 15 m3/hr (9 CFM) vacuum pump (formerly Normetex Pompes, now EumecaSARL). One possible solution proposed by Hydrogen Processing Technology personnel is to use two Senior Aerospace Metal Bellows MB-601 vacuum pumps piped with the heads in series, and the pumps in series (Figure 1 below). This memorandum documents the ultimate vacuum testing that was performed to determine if this concept was a viable alternate vacuum pump strategy. This testing dovetails with previous pump evaluations documented in references 1 and 2.

  13. Science Library of Test Items. Volume Twelve. Mastery Testing Programme. [Mastery Tests Series 4.] Tests M39-M50.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 39 through 50 include: (39) using a code; (40) naming the parts of a microscope; (41) calculating density and predicting flotation; (42) estimating metric length; (43) using SI symbols; (44) using s=vt; (45) applying a novel theory; (46)…

  14. Test performance of the QSE series of 5 cm aperture quadrupole model magnets

    International Nuclear Information System (INIS)

    Archer, B.; Bein, D.; Cunningham, G.; DiMarco, J.; Gathright, T.; Jayakumar, J.; LaBarge, A.; Li, W.; Lambert, D.; Scott, M.

    1994-01-01

    A 5 cm aperture quadrupole design, the QSE series of magnets were the first to be tested in the Short Magnet and Cable Test Laboratory (SMCTL) at the SSCL. Test performance of the first two magnets of the series are presented, including quench performance, quench localization, strain gage readings, and magnetic measurements. Both magnets behaved reasonably well with no quenches below the collider operating current, four training quenches to plateau, and good training memory between thermal cycles. Future magnets in the QSE series will be used to reduce the initial training and to tune out unwanted magnetic harmonics

  15. Test performance of the QSE series of 5 cm aperture quadrupole model magnets

    International Nuclear Information System (INIS)

    Archer, B.; Bein, D.; Cunningham, G.; DiMarco, J.; Gathright, T.; Jayakumar, J.; Labarge, A.; Li, W.; Lambert, D.; Scott, M.; Snitchler, G.; Zeigler, R.

    1993-04-01

    A 5 cm aperture quadrupole design, the QSE series of magnets were the first to be tested in the Short Magnet and Cable Test Laboratory (SMCTL) at the SSCL. Test performance of the first two magnets of the series are presented, including quench performance, quench localization, strain gage readings, and magnetic measurements.Both magnets behaved reasonably well with no quenches below the collider operating current, four training quenches to plateau, and good training memory between thermal cycles. Future magnets in the QSE series will be used to reduce the initial training and to tune out unwanted magnetic harmonics

  16. Explosion overpressure test series: General-Purpose Heat Source development: Safety Verification Test program

    International Nuclear Information System (INIS)

    Cull, T.A.; George, T.G.; Pavone, D.

    1986-09-01

    The General-Purpose Heat Source (GPHS) is a modular, radioisotope heat source that will be used in radioisotope thermoelectric generators (RTGs) to supply electric power for space missions. The first two uses will be the NASA Galileo and the ESA Ulysses missions. The RTG for these missions will contain 18 GPHS modules, each of which contains four 238 PuO 2 -fueled clads and generates 250 W/sub (t)/. A series of Safety Verification Tests (SVTs) was conducted to assess the ability of the GPHS modules to contain the plutonia in accident environments. Because a launch pad or postlaunch explosion of the Space Transportation System vehicle (space shuttle) is a conceivable accident, the SVT plan included a series of tests that simulated the overpressure exposure the RTG and GPHS modules could experience in such an event. Results of these tests, in which we used depleted UO 2 as a fuel simulant, suggest that exposure to overpressures as high as 15.2 MPa (2200 psi), without subsequent impact, does not result in a release of fuel

  17. Plutonium safe handling

    International Nuclear Information System (INIS)

    Tvehlov, Yu.

    2000-01-01

    The abstract, prepared on the basis of materials of the IAEA new leadership on the plutonium safe handling and its storage (the publication no. 9 in the Safety Reports Series), aimed at presenting internationally acknowledged criteria on the radiation danger evaluation and summarizing the experience in the safe management of great quantities of plutonium, accumulated in the nuclear states, is presented. The data on the weapon-class and civil plutonium, the degree of its danger, the measures for provision of its safety, including the data on accident radiation consequences with the fission number 10 18 , are presented. The recommendations, making it possible to eliminate the super- criticality danger, as well as ignition and explosion, to maintain the tightness of the facility, aimed at excluding the radioactive contamination and the possibility of internal irradiation, to provide for the plutonium security, physical protection and to reduce irradiation are given [ru

  18. High heat flux tests of the WENDELSTEIN 7-X pre-series target elements

    International Nuclear Information System (INIS)

    Greuner, H.; Boeswirth, B.; Boscary, J.; Plankensteiner, A.; Schedler, B.

    2007-01-01

    The high heat flux (HHF) testing of WENDELSTEIN 7-X pre-series target elements is an indispensable step in the qualification of the manufacturing process. A set of 20 full scale pre-series elements was manufactured by PLANSEE SE to validate the materials and manufacturing technologies prior to the start of the series production. The HHF tests were performed in the ion beam test facility GLADIS. All actively water-cooled elements were tested for about 100 cycles at 10 MW/m 2 (10-15 s pulse duration). Several elements were loaded with even higher cycle numbers (up to 1000) and heat loads up to 24 MW/m 2 . Hot spots were, observed at the edges of several tiles during the HHF tests indicating local bonding problems of the CFC. The thermo-mechanical behaviour under HHF loading has been evaluated and compared to the FEM predictions. The measured temperatures and strains confirm the chosen FEM approach. This allows a component optimisation to achieve a successful series production of the W7-X divertor target elements

  19. Evaluation of LLTR series II test A-7 results

    International Nuclear Information System (INIS)

    Knittle, D.E.; Amos, J.C.; Yang, T.M.

    1981-09-01

    This report evaluates the test A-7 data and assesses the capability of the analytical methodology (as a result of Series I program) to predict the thermal/hydraulic phenomena associated with a large SWR event occurring after the sodium system pressure has increased to near the rupture disc burst pressure due to a smaller size leak event. Evaluation of intertest examination data to determine the extent of test article damage resulting from test A-7 is also included

  20. Experiment data report for Test RIA 1-2 (Reactivity Initiated Accident Test Series)

    International Nuclear Information System (INIS)

    Zimmermann, C.L.; White, C.E.; Evans, R.P.

    1979-06-01

    Recorded test data are presented for the second of six planned tests in the Reactivity Initiated Accident (RIA) Test Series I, Test RIA 1-2. This test, conducted at the Power Burst Facility, had the following objectives: (1) characterize the response of preirradiated fuel rods during an RIA event conducted at boiling water reactor hot-startup conditions; and (2) evaluate the effect of rod internal pressure on preirradiated fuel rod response during an RIA event. The data from Test RIA 1-2 are graphed in engineering units and have been appraised for quality and validity. These uninterpreted data are presented for use in the nuclear fuel behavior research field before detailed analysis and interpretation have been completed

  1. Results of the mission profile life test. [for J-series mercury ion engines

    Science.gov (United States)

    Bechtel, R. T.; Trump, G. E.; James, E. L.

    1982-01-01

    Seven J series 30-cm diameter thrusters have been tested in segments of up to 5,070 hr, for 14,541 hr in the Mission Profile Life Test facility. Test results have indicated the basic thruster design to be consistent with the lifetime goal of 15,000 hr at 2-A beam. The only areas of concern identified which appear to require additional verification testing involve contamination of mercury propellant isolators, which may be due to facility constituents, and the ability of specially covered surfaces to contain sputtered material and prevent flake formation. The ability of the SCR, series resonant inverter power processor to operate the J series thruster and autonomous computer control of the thruster/processor system were demonstrated.

  2. Tools to Ensure Safe Medicines: New Monograph Tests in USP-NF

    Directory of Open Access Journals (Sweden)

    Catherine Sheehan

    2010-06-01

    Full Text Available This paper describes USP-NF compendial updates to six ‘high-priority” excipient monographs: Glycerin, Propylene Glycol, Sorbitol Solution, Sorbitol Sorbitan Solution, Noncrystallizing Sorbitol Solution and Maltitol Solution. The USP-NF revisions arose from the Food and Drug Administration’s (FDA’s requests to include, as part of each monograph’s Identification test, a limit test to detect the presence of Diethylene Glycol (DEG, a toxic adulterant. These revisions align with the 2007 FDA Guidance for Industry: Testing of Glycerin for Diethylene Glycol (1, that drug product manufacturers perform a specific identity test for DEG on all containers of all lots of glycerin before glycerin is used in the manufacture and preparation of drug products. This paper describes several risk factors due to a complex global excipient supply chain, nonspecific specifications, inadequate supply chain qualification, and poor understanding of regulations. Strengthening and conformance to compendial specifications is one of the tools necessary to mitigate risk and help prevent the next DEG adulteration that is part of USP’s efforts to ensure safe medicines.

  3. Flight Testing a Real-Time Hazard Detection System for Safe Lunar Landing on the Rocket-Powered Morpheus Vehicle

    Science.gov (United States)

    Trawny, Nikolas; Huertas, Andres; Luna, Michael E.; Villalpando, Carlos Y.; Martin, Keith E.; Carson, John M.; Johnson, Andrew E.; Restrepo, Carolina; Roback, Vincent E.

    2015-01-01

    The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.

  4. Irradiation Effects Test Series: Test IE-2. Test results report

    International Nuclear Information System (INIS)

    Allison, C.M.; Croucher, D.W.; Ploger, S.A.; Mehner, A.S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m 2 . After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m 2 , the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m 2 caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations

  5. Premiering SAFE for Safety Added Fuel Element - 15020

    International Nuclear Information System (INIS)

    Bhowmik, P.K.; Shamim, J.A.; Suh, K.Y.; Suh, K.S.

    2015-01-01

    The impact of the Fukushima accident has been the willingness to implement passive safety measures in reactor design and to simplify reactor design itself. Within this framework, a new fuel element, named SAFE (Safety Added Fuel Element) based on the concept of accident tolerant fuel, is presented. SAFE is a new type of fuel element cooled internally and externally by light water and with stainless steel as the cladding material. The removal of boron may trigger a series of changes which may simplify the system greatly. A simplified thermal analysis of SAFE shows that the fuel centerline temperature is well below the maximal limit during the normal operation of the plant

  6. Complexity testing techniques for time series data: A comprehensive literature review

    International Nuclear Information System (INIS)

    Tang, Ling; Lv, Huiling; Yang, Fengmei; Yu, Lean

    2015-01-01

    Highlights: • A literature review of complexity testing techniques for time series data is provided. • Complexity measurements can generally fall into fractality, methods derived from nonlinear dynamics and entropy. • Different types investigate time series data from different perspectives. • Measures, applications and future studies for each type are presented. - Abstract: Complexity may be one of the most important measurements for analysing time series data; it covers or is at least closely related to different data characteristics within nonlinear system theory. This paper provides a comprehensive literature review examining the complexity testing techniques for time series data. According to different features, the complexity measurements for time series data can be divided into three primary groups, i.e., fractality (mono- or multi-fractality) for self-similarity (or system memorability or long-term persistence), methods derived from nonlinear dynamics (via attractor invariants or diagram descriptions) for attractor properties in phase-space, and entropy (structural or dynamical entropy) for the disorder state of a nonlinear system. These estimations analyse time series dynamics from different perspectives but are closely related to or even dependent on each other at the same time. In particular, a weaker self-similarity, a more complex structure of attractor, and a higher-level disorder state of a system consistently indicate that the observed time series data are at a higher level of complexity. Accordingly, this paper presents a historical tour of the important measures and works for each group, as well as ground-breaking and recent applications and future research directions.

  7. Safe Transport of Radioactive Material, Philosophy and Overview

    Energy Technology Data Exchange (ETDEWEB)

    EL-Shinawy, R M.K. [Radiation Protection Dept., Nuclear Rasearch Center, Atomic Energy Authority, Cairo (Egypt)

    2008-07-01

    Safe transport of radioactive material regulations issued by IAEA since 1961, provide standards for insuring a high level of safety of people,transport workers, property and environment against radiation, contamination and criticality hazards as well as thermal effects associated with the transport of the radioactive wastes and material. The history ,development, philosophy and scope of these international and national regulations were mentioned as well as the different supporting documents to the regulations for safe transport of radioactive material were identified.The first supporting document , namely TS - G-1.1(ST-2) ,Advisory material is also issued by the IAEA.It contains both the advisory and explanatory materials previously published in safety series Nos 7and 37 and therefore TS-G-1.1 (ST-2) will supersede safety series Nos 7 and 37. The second supporting document namely TS-G-1.2 (ST-3), planning and preparing for emergency response to transport accidents involving radioactive material ,which will supersede safety series No 87. In addition to quality assurance (SS no.113), compliance assurance (SS no. 112), the training manual and others.

  8. Safe Transport of Radioactive Material, Philosophy and Overview

    International Nuclear Information System (INIS)

    EL-Shinawy, R.M.K.

    2008-01-01

    Safe transport of radioactive material regulations issued by IAEA since 1961, provide standards for insuring a high level of safety of people,transport workers, property and environment against radiation, contamination and criticality hazards as well as thermal effects associated with the transport of the radioactive wastes and material. The history ,development, philosophy and scope of these international and national regulations were mentioned as well as the different supporting documents to the regulations for safe transport of radioactive material were identified.The first supporting document , namely TS - G-1.1(ST-2) ,Advisory material is also issued by the IAEA.It contains both the advisory and explanatory materials previously published in safety series Nos 7and 37 and therefore TS-G-1.1 (ST-2) will supersede safety series Nos 7 and 37. The second supporting document namely TS-G-1.2 (ST-3), planning and preparing for emergency response to transport accidents involving radioactive material ,which will supersede safety series No 87. In addition to quality assurance (SS no.113), compliance assurance (SS no. 112), the training manual and others

  9. A general statistical test for correlations in a finite-length time series.

    Science.gov (United States)

    Hanson, Jeffery A; Yang, Haw

    2008-06-07

    The statistical properties of the autocorrelation function from a time series composed of independently and identically distributed stochastic variables has been studied. Analytical expressions for the autocorrelation function's variance have been derived. It has been found that two common ways of calculating the autocorrelation, moving-average and Fourier transform, exhibit different uncertainty characteristics. For periodic time series, the Fourier transform method is preferred because it gives smaller uncertainties that are uniform through all time lags. Based on these analytical results, a statistically robust method has been proposed to test the existence of correlations in a time series. The statistical test is verified by computer simulations and an application to single-molecule fluorescence spectroscopy is discussed.

  10. Test results on direct containment heating by high-pressure melt ejection into the Surtsey vessel: The TDS test series

    International Nuclear Information System (INIS)

    Allen, M.D.; Blanchat, T.K.; Pilch, M.M.

    1994-08-01

    The Technology Development and Scoping (TDS) test series was conducted to test and develop instrumentation and procedures for performing steam-driven, high-pressure melt ejection (HPME) experiments at the Surtsey Test Facility to investigate direct containment heating (DCH). Seven experiments, designated TDS-1 through TDS-7, were performed in this test series. These experiments were conducted using similar initial conditions; the primary variable was the initial pressure in the Surtsey vessel. All experiments in this test series were performed with a steam driving gas pressure of ≅ 4 MPa, 80 kg of lumina/iron/chromium thermite melt simulant, an initial hole diameter of 4.8 cm (which ablated to a final hole diameter of ≅ 6 cm), and a 1/10th linear scale model of the Surry reactor cavity. The Surtsey vessel was purged with argon ( 2 ) to limit the recombination of hydrogen and oxygen, and gas grab samples were taken to measure the amount of hydrogen produced

  11. Evaluating an Automated Number Series Item Generator Using Linear Logistic Test Models

    Directory of Open Access Journals (Sweden)

    Bao Sheng Loe

    2018-04-01

    Full Text Available This study investigates the item properties of a newly developed Automatic Number Series Item Generator (ANSIG. The foundation of the ANSIG is based on five hypothesised cognitive operators. Thirteen item models were developed using the numGen R package and eleven were evaluated in this study. The 16-item ICAR (International Cognitive Ability Resource1 short form ability test was used to evaluate construct validity. The Rasch Model and two Linear Logistic Test Model(s (LLTM were employed to estimate and predict the item parameters. Results indicate that a single factor determines the performance on tests composed of items generated by the ANSIG. Under the LLTM approach, all the cognitive operators were significant predictors of item difficulty. Moderate to high correlations were evident between the number series items and the ICAR test scores, with high correlation found for the ICAR Letter-Numeric-Series type items, suggesting adequate nomothetic span. Extended cognitive research is, nevertheless, essential for the automatic generation of an item pool with predictable psychometric properties.

  12. Operational Overview for UAS Integration in the NAS Project Flight Test Series 3

    Science.gov (United States)

    Valkov, Steffi B.; Sternberg, Daniel; Marston, Michael

    2018-01-01

    The National Aeronautics and Space Administration Unmanned Aircraft Systems Integration in the National Airspace System Project has conducted a series of flight tests intended to support the reduction of barriers that prevent unmanned aircraft from flying without the required waivers from the Federal Aviation Administration. The 2015 Flight Test Series 3, supported two separate test configurations. The first configuration investigated the timing of Detect and Avoid alerting thresholds using a radar equipped unmanned vehicle and multiple live intruders flown at varying encounter geometries.

  13. Spark-safe power source

    Energy Technology Data Exchange (ETDEWEB)

    Mester, I M; Konushkin, N A; Nevozinskiy, A K; Rubinshteyn, B Sh; Serov, V I; Vasnev, M A

    1981-01-01

    A shortcoming of the known power sources is their low reliability. The purpose of the invention is to improve the reliability of the device. This is achieved because the spark-safe power source is equipped with a by-passing transistor and potentiometer, and also a generator of control interruptions in the circuit, an I-element, first separating transformer, control block, second separating transformer whose secondary winding has a relay winding whose contacts are connected to the load circuit are connected in series. The generator of control separations of the circuit is connected to the base of the by-passing transistor and to the power source outlet, the potentiometer is connected in series to the main thyristor. The middle point of the potentiometer is connected to the second inlet of the I-element.

  14. Radioisotope Thermoelectric Generator Transporation System licensed hardware second certification test series and package shock mount system test

    International Nuclear Information System (INIS)

    Ferrell, P.C.; Moody, D.A.

    1995-10-01

    This paper presents a summary of two separate drop test a e performed in support of the Radioisotope Thermoelectric Generator (RTG) Transportation System (RTGTS). The first portion of this paper presents the second series of drop testing required to demonstrate that the RTG package design meets the requirements of Title 10, Code of Federal Regulations, ''Part 71'' (10 CFR 71). Results of the first test series, performed in July 1994, demonstrated that some design changes were necessary. The package design was modified to improve test performance and the design changes were incorporated into the Safety Analysis Report for Packaging (SARP). The second full-size certification test article (CTA-2) incorporated the modified design and was tested at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. With the successful completion of the test series, and pending DOE Office of Facility Safety Analysis approval of the SARP, a certificate of compliance will be issued for the RTG package allowing its use. The second portion of this paper presents the design and testing of the RTG Package Mount System. The RTG package mount was designed to protect the RTG from excessive vibration during transport, provide shock protection during on/off loading, and provide a mechanism for moving the RTG package with a forklift. Military Standard (MIL-STD) 810E, Transit Drop Procedure (DOE 1989), was used to verify that the shock limiting system limited accelerations in excess of 15 G's at frequencies below 150 Hz. Results of the package mount drop tests indicate that an impact force of 15 G's was not exceeded in any test from a free drop height of 457 mm (18 in.)

  15. Testing for Stationarity and Nonlinearity of Daily Streamflow Time Series Based on Different Statistical Tests (Case Study: Upstream Basin Rivers of Zarrineh Roud Dam

    Directory of Open Access Journals (Sweden)

    Farshad Fathian

    2017-02-01

    Full Text Available Introduction: Time series models are one of the most important tools for investigating and modeling hydrological processes in order to solve problems related to water resources management. Many hydrological time series shows nonstationary and nonlinear behaviors. One of the important hydrological modeling tasks is determining the existence of nonstationarity and the way through which we can access the stationarity accordingly. On the other hand, streamflow processes are usually considered as nonlinear mechanisms while in many studies linear time series models are used to model streamflow time series. However, it is not clear what kind of nonlinearity is acting underlying the streamflowprocesses and how intensive it is. Materials and Methods: Streamflow time series of 6 hydro-gauge stations located in the upstream basin rivers of ZarrinehRoud dam (located in the southern part of Urmia Lake basin have been considered to investigate stationarity and nonlinearity. All data series used here to startfrom January 1, 1997, and end on December 31, 2011. In this study, stationarity is tested by ADF and KPSS tests and nonlinearity is tested by BDS, Keenan and TLRT tests. The stationarity test is carried out with two methods. Thefirst one method is the augmented Dickey-Fuller (ADF unit root test first proposed by Dickey and Fuller (1979 and modified by Said and Dickey (1984, which examinsthe presence of unit roots in time series.The second onemethod is KPSS test, proposed by Kwiatkowski et al. (1992, which examinesthestationarity around a deterministic trend (trend stationarity and the stationarity around a fixed level (level stationarity. The BDS test (Brock et al., 1996 is a nonparametric method for testing the serial independence and nonlinear structure in time series based on the correlation integral of the series. The null hypothesis is the time series sample comes from an independent identically distributed (i.i.d. process. The alternative hypothesis

  16. An Automated Safe-to-Mate (ASTM) Tester

    Science.gov (United States)

    Nguyen, Phuc; Scott, Michelle; Leung, Alan; Lin, Michael; Johnson, Thomas

    2013-01-01

    Safe-to-mate testing is a common hardware safety practice where impedance measurements are made on unpowered hardware to verify isolation, continuity, or impedance between pins of an interface connector. A computer-based instrumentation solution has been developed to resolve issues. The ASTM is connected to the circuit under test, and can then quickly, safely, and reliably safe-to-mate the entire connector, or even multiple connectors, at the same time.

  17. ENRAF Series 854 Advanced Technology Gauge (ATG) Acceptance Test Procedure

    International Nuclear Information System (INIS)

    HUBER, J.H.

    1999-01-01

    This procedure provides acceptance testing for Enraf Series 854 level gauges used to monitor levels in Hanford Waste Storage Tanks. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area. This ATP does not set up the gauge for any specific tank, but is generalized to permit testing the gauge prior to installation package preparation

  18. 78 FR 37463 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Science.gov (United States)

    2013-06-21

    ... Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe Drinking Water Act... page 32570, with the table entitled ``ALTERNATIVE TESTING METHODS FOR CONTAMINANTS LISTED AT 40 CFR 141... Contaminants Listed at 40 CFR 141.25(a) SM 21st Edition SM 22nd Edition Contaminant Methodology \\1\\ \\28\\ ASTM...

  19. Fabrication and testing of W7-X pre-series target elements

    International Nuclear Information System (INIS)

    Boscary, J; Boeswirth, B; Greuner, H; Grigull, P; Missirlian, M; Plankensteiner, A; Schedler, B; Friedrich, T; Schlosser, J; Streibl, B; Traxler, H

    2007-01-01

    The assembly of the highly-loaded target plates of the WENDELSTEIN 7-X (W7-X) divertor requires the fabrication of 890 target elements (TEs). The plasma facing material is made of CFC NB31 flat tiles bonded to a CuCrZr copper alloy water-cooled heat sink. The elements are designed to remove a stationary heat flux and power up to 10 MW m -2 and 100 kW, respectively. Before launching the serial fabrication, pre-series activities aimed at qualifying the design, the manufacturing route and the non-destructive examinations (NDEs). High heat flux (HHF) tests performed on full-scale pre-series TEs resulted in an improvement of the design of the bond between tiles and heat sink to reduce the stresses during operation. The consequence is the fabrication of additional pre-series TEs to be tested in the HHF facility GLADIS. NDEs of this bond based on thermography methods are developed to define the acceptance criteria suitable for serial fabrication

  20. Cryogenic Infrastructure for Testing of LHC Series Superconducting Magnets

    CERN Document Server

    Axensalva, J; Herblin, L; Lamboy, J P; Tovar-Gonzalez, A; Vuillerme, B

    2005-01-01

    The ~1800 superconducting magnets for the LHC machine shall be entirely tested at reception before their installation in the tunnel. For this purpose and in order to reach the reliability and efficiency at the nominal load required for an industrial operation for several years, we have gradually upgraded and retrofitted the cryogenic facilities installed in the early nineties for the testing at CERN of prototypes and preseries magnets. The final infrastructure of the test station, dedicated to check industrially the quality of the series magnets, is now nearly complete. We present the general layout and describe the overall performance of the system.

  1. Electromyography tests in patients with implanted cardiac devices are safe regardless of magnet placement.

    Science.gov (United States)

    Ohira, Masayuki; Silcox, Jade; Haygood, Deavin; Harper-King, Valerie; Alsharabati, Mohammad; Lu, Liang; Morgan, Marla B; Young, Angela M; Claussen, Gwen C; King, Peter H; Oh, Shin J

    2013-01-01

    We compared the problems or complications associated with electrodiagnostic testing in 77 patients with implanted cardiac devices. Thirty tests were performed after magnet placement, and 47 were performed without magnet application. All electrodiagnostic tests were performed safely in all patients without any serious effect on the implanted cardiac devices with or without magnet placement. A significantly higher number of patient symptoms and procedure changes were reported in the magnet group (P magnet group patients had an approximately 11-fold greater risk of symptoms than those in the control group. Our data do not support a recommendation that magnet placement is necessary for routine electrodiagnostic testing in patients with implanted cardiac devices, as long as our general and specific guidelines are followed. Copyright © 2012 Wiley Periodicals, Inc.

  2. Safe Use of Pesticides, Guidelines. Occupational Safety and Health Series No. 38.

    Science.gov (United States)

    International Labour Office, Geneva (Switzerland).

    This document provides guidance on the safe use of pesticides in agricultural work. General principles are given and followed by more detailed safety requirements for the various pesticide application techniques. Finally, the medical aspects of pesticides are considered. (BB)

  3. Nuclear hydrogen production and its safe handling

    International Nuclear Information System (INIS)

    Chung, Hongsuk; Paek, Seungwoo; Kim, Kwang-Rag; Ahn, Do-Hee; Lee, Minsoo; Chang, Jong Hwa

    2003-01-01

    An overview of the hydrogen related research presently undertaken at the Korea Atomic Energy Research Institute are presented. These encompass nuclear hydrogen production, hydrogen storage, and the safe handling of hydrogen, High temperature gas-cooled reactors can play a significant role, with respect to large-scale hydrogen production, if used as the provider of high temperature heat in fossil fuel conversion or thermochemical cycles. A variety of potential hydrogen production methods for high temperature gas-cooled reactors were analyzed. They are steam reforming of natural gas, thermochemical cycles, etc. The produced hydrogen should be stored safely. Titanium metal was tested primarily because its hydride has very low dissociation pressures at normal storage temperatures and a high capacity for hydrogen, it is easy to prepare and is non-reactive with air in the expected storage conditions. There could be a number of potential sources of hydrogen evolution risk in a nuclear hydrogen production facility. In order to reduce the deflagration detonation it is necessary to develop hydrogen control methods that are capable of dealing with the hydrogen release rate. A series of experiments were conducted to assess the catalytic recombination characteristics of hydrogen in an air stream using palladium catalysts. (author)

  4. Comparison of simultaneous patch testing with parthenolide and sesquiterpene lactone mix

    DEFF Research Database (Denmark)

    Orion, E; Paulsen, Evy; Andersen, Klaus Ejner

    1998-01-01

    Several studies have pointed out that the sesquiterpene lactone (SL) mix is a safe, though inadequate, screen for Compositae allergy. To test the usefulness of the sesquiterpene lactone parthenolide as a supplementary Compositae screening test to the mix, both were included in the standard series...

  5. Fail-safe computer-based plant protection systems

    International Nuclear Information System (INIS)

    Keats, A.B.

    1983-01-01

    A fail-safe mode of operation for computers used in nuclear reactor protection systems was first evolved in the UK for application to a sodium cooled fast reactor. The fail-safe properties of both the hardware and the software were achieved by permanently connecting test signals to some of the multiplexed inputs. This results in an unambiguous data pattern, each time the inputs are sequentially scanned by the multiplexer. The ''test inputs'' simulate transient excursions beyond defined safe limits. The alternating response of the trip algorithms to the ''out-of-limits'' test signals and the normal plant measurements is recognised by hardwired pattern recognition logic external to the computer system. For more general application to plant protection systems, a ''Test Signal Generator'' (TSG) is used to compute and generate test signals derived from prevailing operational conditions. The TSG, from its knowledge of the sensitivity of the trip algorithm to each of the input variables, generates a ''test disturbance'' which is superimposed upon each variable in turn, to simulate a transient excursion beyond the safe limits. The ''tripped'' status yielded by the trip algorithm when using data from a ''disturbed'' input forms part of a pattern determined by the order in which the disturbances are applied to the multiplexer inputs. The data pattern formed by the interleaved test disturbances is again recognised by logic external to the protection system's computers. This fail-safe mode of operation of computer-based protection systems provides a powerful defence against common-mode failure. It also reduces the importance of software verification in the licensing procedure. (author)

  6. Meta-Analysis of Data from the Submarine Ventilation Doctrine Test Program

    National Research Council Canada - National Science Library

    Hoover, J

    1998-01-01

    ... in critical spaces or provide safe ingresslegress routes. This program sponsored six test series between January 1995 and August 1996 and made specific recommendations for the use of ventilation during submarine firefighting...

  7. PKL-tests, test series IIB (end of blowdown). Vol. 2

    International Nuclear Information System (INIS)

    Umminger, K.; Mandl, R.; Nopper, H.; Siemens AG Unternehmensbereich KWU, Erlangen

    1987-01-01

    As part of the federally subsidized research project 1500 287/A0, the system behavior of a 1300 MWe pressurized water reactor (PWR) was investigated during the depressurization phase (end-of-blowdown, EOB), as well as during the refill and reflood phases of a loss of coolant accident involving a large break in the reactor coolant loop. Appropriate modifications to the system and supplementary instrumentation have made it possible to simulate the EOB (as of 26 bar), the refill phase and reflood phase in sequence. This report includes a detailed description of the instrumentation and the data acquisition system used in Test Series PKL IIB. (orig.) With 6 refs., 2 tabs., 60 figs [de

  8. USING THE SAFE SYSTEM APPROACH TO KEEP OLDER DRIVERS SAFELY MOBILE

    Directory of Open Access Journals (Sweden)

    Jim LANGFORD

    2006-01-01

    Full Text Available In 2003, Australian road transport jurisdictions collectively accepted that the greatest road safety gains would be achieved through adopting a Safe System approach, derived from Sweden's Vision Zero and the Netherlands' Sustainable Safety strategies. A key objective of all three approaches is to manage vehicles, the road infrastructure, speeds, road users and the interactions between these components, to ensure that in the event of crashes, crash energies will remain at levels that minimize the probability of death and serious injury. Older drivers pose a particular challenge to the Safe System approach, given particularly their greater physical frailty, their driving patterns and for some at least, their reduced fitness to drive. This paper has analyzed the so-called ‘older driver problem’ and identified a number of key factors underpinning their crash levels, for which countermeasures can be identified and implemented within a Safe System framework. The recommended countermeasures consist of: (1 safer roads, through a series of design improvements particularly governing urban intersections; (2 safer vehicles, through both the promotion of crashworthiness as a critical consideration when purchasing a vehicle and the wide use of developed and developing ITS technologies; (3 safer speeds especially at intersections; and (4 safer road users, through both improved assessment procedures to identify the minority of older drivers with reduced fitness to drive and educational efforts to encourage safer driving habits particularly but not only through self-regulation.

  9. Implications of inherent safe nuclear power system

    International Nuclear Information System (INIS)

    Song, Yo-Taik

    1987-01-01

    The safety of present day nuclear power reactors and research reactors depends on a combination of design features of passive and active systems, and the alert judgement of their operators. A few inherently safe designs of nuclear reactors for power plants are currently under development. In these designs, the passive systems are emphasized, and the active systems are minimized. Also efforts are made to eliminate the potential for human failures that initiate the series of accidents. If a major system fails in these designs, the core is flooded automatically with coolants that flow by gravity, not by mechanical pumps or electromagnetic actuators. Depending on the choice of the coolants--water, liquid metal and helium gas--there are three principal types of inherently safe reactors. In this paper, these inherently safe reactor designs are reviewed and their implications are discussed. Further, future perspectives of their acceptance by nuclear industries are discussed. (author)

  10. D-dimer testing for safe exclusion and risk stratification in patients with acute pulmonary embolism in primary care

    Directory of Open Access Journals (Sweden)

    Zhou Yin

    2015-01-01

    Full Text Available Background: Safe exclusion and risk stratification are currently recommended for the initial management of patients with acute pulmonary embolism (APE. The aim of this study was to assess the safe exclusion and risk stratification value of D-dimer (DD for APE when tested at the beginning of admission. Materials and Methods: All consecutive Chinese APE patients and controls were recruited from January 2010 to December 2012. All measurements of serum indexes were made in duplicate and blinded to the patients′ status. All the 40 patients with the first episode of APE were confirmed by multi-detector computed tomographic pulmonary angiography. The plasma prothrombin time (PT, activated partial thromboplastin time, thrombin time, fibrinogen, and DD levels were measured within 24 h of admission. We used the Mann-Whitney U-test to determine the differences between groups and drew receiver operator characteristic curve to evaluate the indexes′ value in the APE screening. Results: The PT and DD in the APE group were significantly higher than those in the disease control group (P 1820 μg/L as cut-off value, the sensitivity, specificity, positive and negative predictive value was 82.5%, 75.2%, 56.9%, and 91.6%, respectively. Conclusion: The patients with APE showed significant higher DD levels compared with disease controls, suggesting a negative qualitative DD test result can safely and efficiently exclude APE in primary care.

  11. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numeracy. Teacher's Manual. Green Series 6.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the Green Series 6 of the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in this series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school…

  12. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numeracy. Teacher's Manual. Blue Series 3.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the Blue Series 3 of the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in the series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school classroom…

  13. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numeracy. Teacher's Manual. Green Series 3.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the Green Series 3 of the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in this series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school…

  14. Testing independence between two Poisson-generated multinomial variables in case-series and cohort studies.

    Science.gov (United States)

    Hocine, Mounia; Guillemot, Didier; Tubert-Bitter, Pascale; Moreau, Thierry

    2005-12-30

    In case-series or cohort studies, we propose a test of independence between the occurrences of two types of recurrent events (such as two repeated infections) related to an intermittent exposure (such as an antibiotic treatment). The test relies upon an extension of a recent method for analysing case-series data, in the presence of one type of recurrent event. The test statistic is derived from a bivariate Poisson generated-multinomial distribution. Simulations for checking the validity of the test concerning the type I error and the power properties are presented. The test is illustrated using data from a cohort on antibiotics bacterial resistance in schoolchildren. Copyright 2005 John Wiley & Sons, Ltd.

  15. Science Library of Test Items. Volume Eight. Mastery Testing Program. Series 3 & 4 Supplements to Introduction and Manual.

    Science.gov (United States)

    New South Wales Dept. of Education, Sydney (Australia).

    Continuing a series of short tests aimed at measuring student mastery of specific skills in the natural sciences, this supplementary volume includes teachers' notes, a users' guide and inspection copies of test items 27 to 50. Answer keys and test scoring statistics are provided. The items are designed for grades 7 through 10, and a list of the…

  16. ORNL rod-bundle heat-transfer test data. Volume 7. Thermal-Hydraulic Test Facility experimental data report for test series 3.07.9 - steady-state film boiling in upflow

    International Nuclear Information System (INIS)

    Mullins, C.B.; Felde, D.K.; Sutton, A.G.; Gould, S.S.; Morris, D.G.; Robinson, J.J.

    1982-05-01

    Thermal-Hydraulic Test Facility (THTF) test series 3.07.9 was conducted by members of the Oak Ridge National Laboratory Pressurized-Water Reactor (ORNL-PWR) Blowdown Heat Transfer (BDHT) Separate-Effects Program on September 11, September 18, and October 1, 1980. The objective of the program is to investigate heat transfer phenomena believed to occur in PWRs during accidents, including small- and large-break loss-of-coolant accidents. Test series 3.07.9 was designed to provide steady-state film boiling data in rod bundle geometry under reactor accident-type conditions. This report presents the reduced instrument responses for THTF test series 3.07.9. Also included are uncertainties in the instrument responses, calculated mass flows, and calculated rod powers

  17. Enraf series 854 Advanced Technology Gauge (ATG) acceptance test procedure. Revision 3

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1995-01-01

    This procedure provides acceptance testing for Enraf Series 854 level gauges used to monitor levels in Hanford Waste Storage Tanks. The test will verify that the gauge functions according to the manufacturer's instructions and specifications and is properly setup prior to being delivered to the tank farm area

  18. Orthogonal series generalized likelihood ratio test for failure detection and isolation. [for aircraft control

    Science.gov (United States)

    Hall, Steven R.; Walker, Bruce K.

    1990-01-01

    A new failure detection and isolation algorithm for linear dynamic systems is presented. This algorithm, the Orthogonal Series Generalized Likelihood Ratio (OSGLR) test, is based on the assumption that the failure modes of interest can be represented by truncated series expansions. This assumption leads to a failure detection algorithm with several desirable properties. Computer simulation results are presented for the detection of the failures of actuators and sensors of a C-130 aircraft. The results show that the OSGLR test generally performs as well as the GLR test in terms of time to detect a failure and is more robust to failure mode uncertainty. However, the OSGLR test is also somewhat more sensitive to modeling errors than the GLR test.

  19. Pin failure modeling of the A series CABRI tests

    International Nuclear Information System (INIS)

    Young, M.F.; Portugal, J.L.

    1978-01-01

    The EXPAND pin fialure model, a research tool designed to model pin failure under prompt burst conditions, has been used to predict failure conditions for several of the A series CABRI tests as part of the United States participation in the CABRI Joint Project. The Project is an international program involving France, Germany, England, Japan, and the United States and has the goal of obtaining experimental data relating to the safety of LMFBR's. The A series, designed to simulate high ramp rate TOP conditions, initially utilizes single, fresh UO 2 pins of the PHENIX type in a flowing sodium loop. The pins are preheated at constant power in the CABRI reactor to establish steady state conditions (480 w/cm at the axial peak) and then subjected to a power pulse of 14 ms to 24 ms duration

  20. Testing Commodities as Safe Haven and Hedging Instrument on ASEAN's Five Stock Markets

    Directory of Open Access Journals (Sweden)

    Robiyanto Robiyanto

    2017-08-01

    Full Text Available This study attempts to analyze commodity market instruments such as gold, silver, platinum, palladium, and West Texas Intermediate (WTI crude oil’s potential as hedge and safe haven toward some stock markets in South East Asia such as in Indonesia, Singapore, Malaysia, Philippines, and Thailand. To analyze the data, GARCH (1,1 was applied. The research findings showed that gold, silver, platinum, palladium, and WTI could not play their role as hedging instrument for five South East Asian capital markets. WTI could act as a robust safe haven for most South East Asian capital markets. Gold could do the role as a robust safe haven in Singapore and Malaysia, whereas, platinum and silver consistently could be safe haven only for Singapore Stock Exchange. Palladium could only be safe haven for Philippines Stock Exchange.

  1. 75 FR 32295 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Science.gov (United States)

    2010-06-08

    ... Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe Drinking Water Act... methods for use in measuring the levels of contaminants in drinking water and determining compliance with... required to measure contaminants in drinking water samples. In addition, EPA Regions as well as States and...

  2. High voltage series protection of neutral injectors with crossed-field tubes

    International Nuclear Information System (INIS)

    Hofmann, G.A.; Thomas, D.G.

    1976-01-01

    High voltage neutral beam injectors for fusion machines require either parallel or series protection schemes to limit fault currents in case of arcing to safe levels. The protection device is usually located between the high voltage supply and beam injector and either crowbars (parallel protection) or disconnects (series protection) the high voltage supply when a fault occurs. Because of its isolating property, series protection is preferred. The Hughes crossed-field tube is uniquely suited for series protection schemes. The tube can conduct 40 A continuously upon application of voltage (approximately 300 V) and a static magnetic field (approximately 100 G). It is also capable of interrupting currents of 1000 A within 10 μs and withstand voltage of more than 120 kV. Experiments were performed to simulate the duty of a crossed-field tube as a series protection element in a neutral injector circuit under fault conditions. Results of on-switching tests under high and low voltage and interruption of fault currents are presented. An example of a possible protection circuit with crossed-field tubes is discussed

  3. A new non-parametric stationarity test of time series in the time domain

    KAUST Repository

    Jin, Lei; Wang, Suojin; Wang, Haiyan

    2014-01-01

    © 2015 The Royal Statistical Society and Blackwell Publishing Ltd. We propose a new double-order selection test for checking second-order stationarity of a time series. To develop the test, a sequence of systematic samples is defined via Walsh

  4. Performing T-tests to Compare Autocorrelated Time Series Data Collected from Direct-Reading Instruments.

    Science.gov (United States)

    O'Shaughnessy, Patrick; Cavanaugh, Joseph E

    2015-01-01

    Industrial hygienists now commonly use direct-reading instruments to evaluate hazards in the workplace. The stored values over time from these instruments constitute a time series of measurements that are often autocorrelated. Given the need to statistically compare two occupational scenarios using values from a direct-reading instrument, a t-test must consider measurement autocorrelation or the resulting test will have a largely inflated type-1 error probability (false rejection of the null hypothesis). A method is described for both the one-sample and two-sample cases which properly adjusts for autocorrelation. This method involves the computation of an "equivalent sample size" that effectively decreases the actual sample size when determining the standard error of the mean for the time series. An example is provided for the one-sample case, and an example is given where a two-sample t-test is conducted for two autocorrelated time series comprised of lognormally distributed measurements.

  5. Safe Transport of Radioactive Material, International Regulations and its Supporting Documents

    International Nuclear Information System (INIS)

    El-Shinawy, R.M.K.

    2005-01-01

    Safe transport of radioactive material regulations issued by IAEA since 1961, provide standards for insuring a high level of safety of people,transport workers, property and environment against radiation, contamination and criticality hazards as well as thermal effects associated with the transport of the radioactive wastes and material. The history ,development, philosophy and scope of these international regulations were mentioned as well as the different supporting documents to the regulations for safe transport of radioactive material were identified.The first supporting document , namely TS - G-1.1 ( ST-2) ,Advisory material is also issued by the IAEA.It contains both the advisory and explanatory materials previously published in safety series No 7 and 37 and therefore TS-G-1.1 (ST-2) will supersede safety series No 7 and 37. The second supporting document namely TS-G-1.2 (ST-3), planning and preparing for emergency response to transport accidents involving radioactive material ,which will supersede safety series No 87. In addition to quality assurance (SS=113), compliance assurance (SS=112), the training manual and other

  6. Safe Transport of Radioactive Material, International Regulations and its Supporting Documents

    Energy Technology Data Exchange (ETDEWEB)

    El-Shinawy, R M.K. [Radiation Protection Dept., NRC, Atomic Energy Authority, Cairo (Egypt)

    2005-04-01

    Safe transport of radioactive material regulations issued by IAEA since 1961, provide standards for insuring a high level of safety of people,transport workers, property and environment against radiation, contamination and criticality hazards as well as thermal effects associated with the transport of the radioactive wastes and material. The history ,development, philosophy and scope of these international regulations were mentioned as well as the different supporting documents to the regulations for safe transport of radioactive material were identified.The first supporting document , namely TS - G-1.1 ( ST-2) ,Advisory material is also issued by the IAEA.It contains both the advisory and explanatory materials previously published in safety series No 7 and 37 and therefore TS-G-1.1 (ST-2) will supersede safety series No 7 and 37. The second supporting document namely TS-G-1.2 (ST-3), planning and preparing for emergency response to transport accidents involving radioactive material ,which will supersede safety series No 87. In addition to quality assurance (SS=113), compliance assurance (SS=112), the training manual and other.

  7. Test and evaluation plan for Project W-314 tank farm restoration and safe operations

    International Nuclear Information System (INIS)

    Hays, W.H.

    1998-01-01

    The ''Tank Farm Restoration and Safe Operations'' (TFRSO), Project W-314 will restore and/or upgrade existing Hanford Tank Farm facilities and systems to ensure that the Tank Farm infrastructure will be able to support near term TWRS Privatization's waste feed delivery and disposal system and continue safe management of tank waste. The capital improvements provided by this project will increase the margin of safety for Tank Farms operations, and will aid in aligning affected Tank Farm systems with compliance requirements from applicable state, Federal, and local regulations. Secondary benefits will be realized subsequent to project completion in the form of reduced equipment down-time, reduced health and safety risks to workers, reduced operating and maintenance costs, and minimization of radioactive and/or hazardous material releases to the environment. The original regulatory (e.g., Executive Orders, WACS, CFRS, permit requirements, required engineering standards, etc.) and institutional (e.g., DOE Orders, Hanford procedures, etc.) requirements for Project W-314 were extracted from the TWRS S/RIDs during the development of the Functions and Requirements (F and Rs). The entire family of requirements were then validated for TWRS and Project W-314. This information was contained in the RDD-100 database and used to establish the original CDR. The Project Hanford Management Contract (PHMC) team recognizes that safety, quality, and cost effectiveness in the Test and Evaluation (T and E) program is achieved through a planned systematic approach to T and E activities. It is to this end that the Test and Evaluation Plan (TEP) is created. The TEP for the TFRSO Project, was developed based on the guidance in HNF-IP-0842, and the Good Practice Guide GPG-FM-005, ''Test and Evaluation,'' which is derived from DOE Order 430.1, ''Life Cycle Asset Management.'' It describes the Test and Evaluation program for the TFRSO project starting with the definitive design phase and ending

  8. Safe sex

    Science.gov (United States)

    ... sex; Sexually transmitted - safe sex; GC - safe sex; Gonorrhea - safe sex; Herpes - safe sex; HIV - safe sex; ... contact. STIs include: Chlamydia Genital herpes Genital warts Gonorrhea Hepatitis HIV HPV Syphilis STIs are also called ...

  9. Feedback control of a primary pump for safe and stable operation of a PIUS-type reactor

    International Nuclear Information System (INIS)

    Tasaka, K.; Imai, S.; Masaoka, H.; Tamaki, M.; Kukita, Y.

    1993-01-01

    A new automatic pump speed control system by using a measurement of the temperature distribution in the lower density lock is proposed for the PIUS-type reactor. This control system maintains the fluid temperature at the axial center of the lower density lock at the average of the fluid temperatures below and above the density lock in order to prevent the poison water from penetrating into the core during normal operation. The effectiveness of this control system was successfully confirmed by a series of experiments such as start-up and power ramping tests for the stable normal operation and a loss-of-feedwater test for the safe shutdown in an accident condition, using a small scale atmospheric pressure test loop which simulated the PIUS principle. (orig.)

  10. A new non-parametric stationarity test of time series in the time domain

    KAUST Repository

    Jin, Lei

    2014-11-07

    © 2015 The Royal Statistical Society and Blackwell Publishing Ltd. We propose a new double-order selection test for checking second-order stationarity of a time series. To develop the test, a sequence of systematic samples is defined via Walsh functions. Then the deviations of the autocovariances based on these systematic samples from the corresponding autocovariances of the whole time series are calculated and the uniform asymptotic joint normality of these deviations over different systematic samples is obtained. With a double-order selection scheme, our test statistic is constructed by combining the deviations at different lags in the systematic samples. The null asymptotic distribution of the statistic proposed is derived and the consistency of the test is shown under fixed and local alternatives. Simulation studies demonstrate well-behaved finite sample properties of the method proposed. Comparisons with some existing tests in terms of power are given both analytically and empirically. In addition, the method proposed is applied to check the stationarity assumption of a chemical process viscosity readings data set.

  11. Social safeness and disordered eating: Exploring underlying mechanisms of body appreciation and inflexible eating.

    Science.gov (United States)

    Pinto, Catarina; Ferreira, Cláudia; Mendes, Ana Laura; Trindade, Inês A

    2017-06-01

    Feelings of social safeness and connectedness have been associated with adaptive emotion regulation processes and well-being indicators. Further, literature has demonstrated that interpersonal experiences play an important role in the etiology and maintenance of body and eating psychopathology. However, the study of the role of social variables and emotion regulation processes in the engagement in inflexible eating rules and eating psychopathology is still in its early stages. The current study aims to fill some gaps within the literature and explore the mediator role of body appreciation and inflexible eating rules in the link between social safeness and disordered eating. Participants were 253 women, aged between 18 and 50 years old, who completed a series of online self-report measures. Results from the tested path analysis model showed that social safeness holds a significant effect on eating psychopathology, through the mechanisms of body appreciation and inflexible eating rules. Also, results suggested that women who present higher levels of social safeness tend to present a more positive and respectful attitude towards their body and decreased adoption of inflexible eating rules, which seem to explain lower levels of disordered eating behaviours. These findings seem to present empirical support for the development of intervention programs that promote a positive, affectionate and healthy relationship with one's body image, in order to prevent the inflexible adherence to eating rules and disordered eating behaviours.

  12. Safe Handling of Radioisotopes. 1973 Edition

    International Nuclear Information System (INIS)

    1973-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it was considered an urgent task to provide users of radionuclides with a manual of practice for the safe handling of these substances. The first edition of such a manual was published in 1958 and represented the first of the ''Safety Series'', a series of manuals and codes on health and safety published by the Agency. It was prepared after careful consideration of existing national and international codes of radiation safety by a group of international experts and in consultation with other international bodies. This edition presents the second revision. In response to the suggestion made by some Member States, the term 'radioisotopes' has been changed to 'radionuclides' in the title and, as appropriate, in the text because the term 'radionuclides' includes the radioactive element itself as well as the isotopes. The series of manuals and codes published in the Safety Series and the Technical Reports Series give more complete advice to the user on specialized topics.

  13. A Cryogenic Test Station for the Pre-series 2400 W @ 1.8 K Refrigeration Units for the LHC

    CERN Document Server

    Claudet, S; Gully, P; Jäger, B; Millet, F; Roussel, P; Tavian, L

    2002-01-01

    The cooling capacity below 2 K for the superconducting magnets in the Large Hadron Collider (LHC), at CERN, will be provided by eight refrigeration units at 1.8 K, each of them coupled to a 4.5 K refrigerator. The supply of the series units is linked to successful testing and acceptance of the pre-series delivered by the two selected vendors. To properly assess the performance of specific components such as cold compressors and some process specificities a dedicated test station is necessary. The test station is able to process up to 130 g/s between 4.5 & 20 K and aims at simulating the steady and transient operational modes foreseen for the LHC. After recalling the basic characteristics of the 1.8 K refrigeration units and the content of the acceptance tests of the pre-series, the principle of the test cryostat is detailed. The components of the test station and corresponding layout are described. The first testing experience is presented as well as preliminary results of the pre-series units.

  14. Overview of the 6 Meter HIAD Inflatable Structure and Flexible TPS Static Load Test Series

    Science.gov (United States)

    Swanson, Greg; Kazemba, Cole; Johnson, Keith; Calomino, Anthony; Hughes, Steve; Cassell, Alan; Cheatwood, Neil

    2014-01-01

    To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). At the beginning of 2014, a 6m HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify the designs structural performance. The 6m HIAD structure was constructed in a stacked toroid configuration using nine inflatable torus segments composed of fiber reinforced thin films, which were joined together using adhesives and high strength textile woven structural straps to help distribute the loads throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for displacement of the inflatable structure as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The centerbody of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to provide many data sets including: deformed shape, shoulder deflection, strap loads, cord loads, inflation pressures, and applied static load

  15. Test series 1: seismic-fragility tests of naturally-aged Class 1E Gould NCX-2250 battery cells

    International Nuclear Information System (INIS)

    Bonzon, L.L.; Hente, D.B.; Kukreti, B.M.; Schendel, J.S.; Tulk, J.D.; Janis, W.J.; Black, D.A.; Paulsen, G.D.; Aucoin, B.D.

    1984-09-01

    The seismic-fragility response of naturally-aged, nuclear station, safety-related batteries is of interest for two reasons: (1) to determine actual failure modes and thresholds; and (2) to determine the validity of using the electrical capacity of individual cells as an indicator of the end-of-life of a battery, given a seismic event. This report covers the first test series of an extensive program using 12-year old, lead-calcium, Gould NCX-2250 cells, from the James A. Fitzpatrick Nuclear Power Station operated by the New York Power Authority. Seismic tests with three cell configurations were performed using a triaxial shake table: single-cell tests, rigidly mounted; multi-cell (three) tests, mounted in a typical battery rack; and single-cell tests specifically aimed towards examining propagation of pre-existing case cracks. In general the test philosophy was to monitor the electrical properties including discharge capacity of cells through a graduated series of g-level step increases until either the shake-table limits were reached or until electrical failure of the cells occurred. Of nine electrically active cells, six failed during seismic testing over a range of imposed g-level loads in excess of a 1-g ZPA. Post-test examination revealed a common failure mode, the cracking at the abnormally brittle, positive lead bus-bar/post interface; further examination showed that the failure zone was extremely coarse grained and extensively corroded. Presently accepted accelerated-aging methods for qualifying batteries, per IEEE Std. 535-1979, are based on plate growth, but these naturally-aged 12-year old cells showed no significant plate growth

  16. Test Series 4: seismic-fragility tests of naturally-aged Exide EMP-13 battery cells

    International Nuclear Information System (INIS)

    Bonzon, L.L.; Hente, D.B.; Kukreti, B.M.; Schendel, J.; Tulk, J.D.; Janis, W.J.; Black, D.A.; Paulsen, G.D.; Aucoin, B.D.

    1985-03-01

    This report, the fourth in a test series of an extensive seismic research program, covers the testing of a 27-year old lead-antimony Exide EMP-13 cells from the recently decommissioned Shippingport Atomic Power Station. The Exide cells were tested in two configurations using a triaxial shake table: single-cell tests, rigidly mounted; and multicell (five-cell) tests, mounted in a typical battery rack. A total of nine electrically active cells was used in the two different cell configurations. None of the nine cells failed during the actual seismic tests when a range of ZPAs up to 1.5 g was imposed. Subsequent discharge capacity tests of five of the cells showed, however, that none of the cells could deliver the accepted standard of 80% of their rated electrical capacity for 3 hours. In fact, none of the 5 cells could deliver more than a 33% capacity. Two of the seismically tested cells and one untested, low capacity cell were disassembled for examination and metallurgical analyses. The inspection showed the cells to be in poor condition. The negative plates in the vicinity of the bus connections were extremely weak, the positive buses were corroded and brittle, negative and positive active material utilization was extremely uneven, and corrosion products littered the cells

  17. The WIPP research and development test program

    International Nuclear Information System (INIS)

    Tyler, L.D.

    1985-01-01

    The WIPP (Waste Isolation Pilot Plant) is a DOE RandD Facility for the purpose of developing the technology needed for the safe disposal of the United States defense-related radioactive waste. The in-situ test program is defined for the thermal-structural interactions, plugging and sealing, and waste package interactions in a salt environment. An integrated series of large-scale underground tests address the issues of both systems and long-term isolation performance of a repository

  18. Power source with spark-safe outlet

    Energy Technology Data Exchange (ETDEWEB)

    Tsesarenko, N P; Alekhin, A V

    1982-01-01

    The invention refers to the technique of electrical monitoring and control in systems operating in a spark-safe medium (for example, in coal mines). A more accurate area of application is mobile objects with autonomous source of electricity (mine diesel locomotives, battery electric locomotives etc.). The purpose of the invention is to simplify and to improve the reliability of the planned device, and also to expand the area of application for conditions when it is powered from an autonomous generator of direct voltage. This goal is achieved because the power source with spark-safe outlet (the source contains a thyristor of advance disconnection, connected by anode to the delimiting throttle, one outlet of which is connected to the capacitor included between the controlling electrode and the anode of the thyristor, and the capacitor is connected through the resistor parallel to the outlet clamps of the source, while the thyristor of emergency protection connected parallel to the inlet clamps of the power source) is additionally equipped with a current sensor, hercon, transistor key (included in series in the power circuit) and optron, whose emitter is connected parallel to the current sensor connected in series to the inlet of the power source, while the receiver of the optron is connected in a circuit for controlling the thyristor of emergency protection. Hercon is built into the core of the delimiting throttle and is connected to the circuit for controlling the transistor key.

  19. Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use

    DEFF Research Database (Denmark)

    Schalock, Peter C; Menné, Torkil; Johansen, Jeanne D

    2011-01-01

    algorithm to guide the selection of screening allergen series for patch testing is provided. At a minimum, an extended baseline screening series and metal screening is necessary. Static and dynamic orthopaedic implants, intravascular stent devices, implanted defibrillators and dental and gynaecological......Cutaneous and systemic hypersensitivity reactions to implanted metals are challenging to evaluate and treat. Although they are uncommon, they do exist, and require appropriate and complete evaluation. This review summarizes the evidence regarding evaluation tools, especially patch and lymphocyte...... transformation tests, for hypersensitivity reactions to implanted metal devices. Patch test evaluation is the gold standard for metal hypersensitivity, although the results may be subjective. Regarding pre-implant testing, those patients with a reported history of metal dermatitis should be evaluated by patch...

  20. Oral Surgical Procedures Performed Safely in Patients With Head and Neck Arteriovenous Malformations: A Retrospective Case Series of 12 Patients.

    Science.gov (United States)

    Karim, Abdul Basit; Lindsey, Sean; Bovino, Brian; Berenstein, Alejandro

    2016-02-01

    This case series describes patients with head and neck arteriovenous malformations who underwent oral and maxillofacial surgical procedures combined with interventional radiology techniques to minimize blood loss. Twelve patients underwent femoral cerebral angiography to visualize the extent of vascular malformation. Before the surgical procedures, surgical sites were devascularized by direct injection of hemostatic or embolic agents. Direct puncture sclerotherapy at the base of surgical sites was performed using Surgiflo or n-butylcyanoacrylate glue. Surgical procedures were carried out in routine fashion. A hemostatic packing of FloSeal, Gelfoam, and Avitene was adapted to the surgical sites. Direct puncture sclerotherapy with Surgiflo or n-butylcyanoacrylate glue resulted in minimal blood loss intraoperatively. Local application of the FloSeal, Gelfoam, and Avitene packing sustained hemostasis and produced excellent healing postoperatively. Patients with arteriovenous malformations can safely undergo routine oral and maxillofacial surgical procedures with minimal blood loss when appropriate endovascular techniques and local hemostatic measures are used by the interventional radiologist and oral and maxillofacial surgeon. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Recommendation to test limonene hydroperoxides 0·3% and linalool hydroperoxides 1·0% in the British baseline patch test series.

    Science.gov (United States)

    Wlodek, C; Penfold, C M; Bourke, J F; Chowdhury, M M U; Cooper, S M; Ghaffar, S; Green, C; Holden, C R; Johnston, G A; Mughal, A A; Reckling, C; Sabroe, R A; Stone, N M; Thompson, D; Wilkinson, S M; Buckley, D A

    2017-12-01

    There is a significant rate of sensitization worldwide to the oxidized fragrance terpenes limonene and linalool. Patch testing to oxidized terpenes is not routinely carried out; the ideal patch test concentration is unknown. To determine the best test concentrations for limonene and linalool hydroperoxides, added to the British baseline patch test series, to optimize detection of true allergy and to minimize irritant reactions. During 2013-2014, 4563 consecutive patients in 12 U.K. centres were tested to hydroperoxides of limonene in petrolatum (pet.) 0·3%, 0·2% and 0·1%, and hydroperoxides of linalool 1·0%, 0·5% and 0·25% pet. Irritant reactions were recorded separately from doubtful reactions. Concomitant reactions to other fragrance markers and clinical relevance were documented. Limonene hydroperoxide 0·3% gave positive reactions in 241 (5·3%) patients, irritant reactions in 93 (2·0%) and doubtful reactions in 110 (2·4%). Linalool hydroperoxide 1·0% gave positive reactions in 352 (7·7%), irritant reactions in 178 (3·9%) and doubtful reactions in 132 (2·9%). A total of 119 patients with crescendo reactions to 0·3% limonene would have been missed if only tested with 0·1% and 131 patients with crescendo reactions to 1·0% linalool would have been missed if only tested with 0·25%. In almost two-thirds of patients with positive patch tests to limonene and linalool the reaction was clinically relevant. The majority of patients did not react to any fragrance marker in the baseline series. We recommend that limonene hydroperoxides be tested at 0·3% and linalool hydroperoxides at 1·0% in the British baseline patch test series. © 2017 British Association of Dermatologists.

  2. Teaching Family Caregivers to Assist Safely with Mobility.

    Science.gov (United States)

    Powell-Cope, Gail; Pippins, Karla M; Young, Heather M

    2017-12-01

    : This article is part of a series, Supporting Family Caregivers: No Longer Home Alone, published in collaboration with the AARP Public Policy Institute. Results of focus groups, conducted as part of the AARP Public Policy Institute's No Longer Home Alone video project, supported evidence that family caregivers aren't given the information they need to manage the complex care regimens of family members. This series of articles and accompanying videos aims to help nurses provide caregivers with the tools they need to manage their family member's health care at home.The articles in this new installment of the series explain principles for promoting safe mobility that nurses should reinforce with family caregivers. Each article also includes an informational tear sheet-Information for Family Caregivers-that contains links to instructional videos. To use this series, nurses should read the article first, so they understand how best to help family caregivers, and then encourage the caregivers to watch the videos and ask questions. For additional information, see Resources for Nurses.

  3. Automated classification of Permanent Scatterers time-series based on statistical characterization tests

    Science.gov (United States)

    Berti, Matteo; Corsini, Alessandro; Franceschini, Silvia; Iannacone, Jean Pascal

    2013-04-01

    The application of space borne synthetic aperture radar interferometry has progressed, over the last two decades, from the pioneer use of single interferograms for analyzing changes on the earth's surface to the development of advanced multi-interferogram techniques to analyze any sort of natural phenomena which involves movements of the ground. The success of multi-interferograms techniques in the analysis of natural hazards such as landslides and subsidence is widely documented in the scientific literature and demonstrated by the consensus among the end-users. Despite the great potential of this technique, radar interpretation of slope movements is generally based on the sole analysis of average displacement velocities, while the information embraced in multi interferogram time series is often overlooked if not completely neglected. The underuse of PS time series is probably due to the detrimental effect of residual atmospheric errors, which make the PS time series characterized by erratic, irregular fluctuations often difficult to interpret, and also to the difficulty of performing a visual, supervised analysis of the time series for a large dataset. In this work is we present a procedure for automatic classification of PS time series based on a series of statistical characterization tests. The procedure allows to classify the time series into six distinctive target trends (0=uncorrelated; 1=linear; 2=quadratic; 3=bilinear; 4=discontinuous without constant velocity; 5=discontinuous with change in velocity) and retrieve for each trend a series of descriptive parameters which can be efficiently used to characterize the temporal changes of ground motion. The classification algorithms were developed and tested using an ENVISAT datasets available in the frame of EPRS-E project (Extraordinary Plan of Environmental Remote Sensing) of the Italian Ministry of Environment (track "Modena", Northern Apennines). This dataset was generated using standard processing, then the

  4. Performance Evaluation and Quality Assurance Management during the Series Power Tests of LHC Main Lattice Magnets

    CERN Document Server

    Siemko, A

    2008-01-01

    Within the LHC magnet program a series production of superconducting dipoles and quadrupoles has recently been completed in industry and all magnets were cold tested at CERN. The main features of these magnets are: two-in-one structure, 56 mm aperture, two layer coils wound from 15.1 mm wide Nb-Ti cables, and all-polyimide insulation. This paper reviews the process of the power test quality assurance and performance evaluation, which was applied during the LHC magnet series tests. The main test results of magnets tested in both supercritical and superfluid helium, including the quench training, the conductor performance, the magnet protection efficiency and the electrical integrity are presented and discussed in terms of the design parameters and the requirements of the LHC project.

  5. A 'simple anterior fish excluder' (SAFE for mitigating penaeid-trawl bycatch.

    Directory of Open Access Journals (Sweden)

    Matthew J McHugh

    Full Text Available Various plastic strips and sheets (termed 'simple anterior fish excluders'-SAFEs were positioned across the openings of penaeid trawls in attempts at reducing the unwanted bycatches of small teleosts. Initially, three SAFEs (a single wire without, and with small and large plastic panels were compared against a control (no SAFE on paired beam trawls. All SAFEs maintained targeted Metapenaeus macleayi catches, while the largest plastic SAFE significantly reduced total bycatch by 51% and the numbers of Pomatomus saltatrix, Mugil cephalus and Herklotsichthys castelnaui by up to 58%. A redesigned SAFE ('continuous plastic' was subsequently tested (against a control on paired otter trawls, significantly reducing total bycatch by 28% and P. saltatrix and H. castelnaui by up to 42%. The continuous-plastic SAFE also significantly reduced M. macleayi catches by ~7%, but this was explained by ~5% less wing-end spread, and could be simply negated through otter-board refinement. Further work is required to refine the tested SAFEs, and to quantify species-specific escape mechanisms. Nevertheless, the SAFE concept might represent an effective approach for improving penaeid-trawl selectivity.

  6. Safe corridors for K-wiring in phalangeal fractures

    Directory of Open Access Journals (Sweden)

    C Rex

    2015-01-01

    Conclusion: K-wiring through the safe corridor has proved to yield the best clinical results because of least tethering of soft tissues as evidenced by performing "on-table active finger movement test" at the time of surgery. We strongly recommend K-wiring through safe portals in all phalangeal fractures.

  7. General-Purpose Heat Source development: Safety Verification Test Program. Bullet/fragment test series

    Energy Technology Data Exchange (ETDEWEB)

    George, T.G.; Tate, R.E.; Axler, K.M.

    1985-05-01

    The radioisotope thermoelectric generator (RTG) that will provide power for space missions contains 18 General-Purpose Heat Source (GPHS) modules. Each module contains four /sup 238/PuO/sub 2/-fueled clads and generates 250 W/sub (t)/. Because a launch-pad or post-launch explosion is always possible, we need to determine the ability of GPHS fueled clads within a module to survive fragment impact. The bullet/fragment test series, part of the Safety Verification Test Plan, was designed to provide information on clad response to impact by a compact, high-energy, aluminum-alloy fragment and to establish a threshold value of fragment energy required to breach the iridium cladding. Test results show that a velocity of 555 m/s (1820 ft/s) with an 18-g bullet is at or near the threshold value of fragment velocity that will cause a clad breach. Results also show that an exothermic Ir/Al reaction occurs if aluminum and hot iridium are in contact, a contact that is possible and most damaging to the clad within a narrow velocity range. The observed reactions between the iridium and the aluminum were studied in the laboratory and are reported in the Appendix.

  8. Residential Tornado Safe Rooms from Commodity Wood Products: Wall Development and Impact Testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell; John C. Hermanson

    2015-01-01

    In the United States, tornadoes cause significant damage and result in many injuries and deaths. Although the development and use of tornado safe rooms and shelters have helped reduce the human toll associated with these events, the cost of these structures is often too high for many that could benefit from their use. The development of a residential tornado safe room...

  9. Summary of results from velocity profile tests and wastage tests in support of LLTR series II test A-4

    International Nuclear Information System (INIS)

    Greene, D.A.

    1981-01-01

    The following conclusions were drawn from the experimental program conducted in support of LLTR (Large Leak Test Rig) Series II Test A-4: Fabrication technique for making precise slits was developed. Wastage boundary agrees with velocity profile boundary. Circumferential slit angles would have to be 120 0 to ensure adequate coverage of adjacent tubes. 120 0 circumferential slit weakens tubes such that maintaining desired slit dimensions for LLTI application is not considered practical. Use of intermittent slit geometry would be required. 120 0 slits, precisely machined and precisely aligned with target tubes, produced different penetration rates on adjacent tubes. Production of simultaneous failures in LLTI with 120 0 slit or simulated interrupted slit is not considered credible

  10. Experiment data report for Semiscale Mod-1 Test S-28-1 (steam generator tube rupture test series)

    International Nuclear Information System (INIS)

    Collins, B.L.; Coppin, C.E.; Sackett, K.E.

    1977-10-01

    Recorded test data are presented for Test S-28-1 of the Semiscale Mod-1 steam generator tube rupture test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-28-1 was conducted from initial conditions of 15 767 kPa and 557 K to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the broken loop cold leg piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. Sixty steam generator tube ruptures were simulated by a controlled injection from a heated accumulator into the intact loop hot leg

  11. Advisory material for the IAEA regulations for the safe transport of radioactive material. Safety guide

    International Nuclear Information System (INIS)

    2008-01-01

    Since the first edition in 1961, the Regulations for the Safe Transport of Radioactive Material of the IAEA (IAEA Regulations) have served as the basis of safety for the transport of radioactive material worldwide. In the discussions leading to the first edition of the IAEA Regulations, it was realized that there was need for a publication to supplement the Regulations which could give information of individual provisions as to their purpose, their scientific background and how to apply them in practice. In response, the Agency published Safety Series No. 7, entitled, in its first edition in 1961, 'Notes on Certain Aspects of the Regulations'. An additional source of information on the Regulations, providing advice on 'how' the user should comply with them which could be augmented from time to time in the light of latest experience, was provided by the Agency, initially in relation to the 1973 edition of the Regulations. This was entitled 'Advisory Material for the IAEA Regulations for the Safe Transport of Radioactive Material' and designated Safety Series No. 37. This document is the result of combining the two Safety Series in a single publication. Thus the primary purpose of this publication is to provide guidance to users on proven and acceptable ways of complying with the Regulations. This Advisory Material is not a stand-alone text and it only has significance when used as a companion to the IAEA Safety Standards Series No. ST-1, Regulations for the Safe Transport of Radioactive Material (1996 edition)

  12. Seismic design margin evaluation of systems and equipment required for safe shutdown of North Anna, Units 1 and 2, following an SSE (safe-shutdown earthquake) event. Technical report

    International Nuclear Information System (INIS)

    Desai, K.D.

    1981-06-01

    The Advisory Committee on Reactor Safeguards recommended that the NRC staff review in detail the capability and available seismic design margin of fluid systems and equipment used in North Anna, Units 1 and 2 to achieve safe shutdown following a site-design safe-shutdown earthquake (SSE). The staff conducted a series of plant visits and meetings with the licensee to view and discuss the seismic design methodology used for systems, equipment and their supports. The report is a description and evaluation of the seismic design criteria, design conservatisms and seismic design margin for North Anna, Units 1 and 2

  13. Explanatory material for the IAEA regulations for the safe transport of radioactive material (1985 edition). 2. ed

    International Nuclear Information System (INIS)

    1987-01-01

    This document pertains to Safety Series No. 7 of the IAEA, which is to explain the provisions of the IAEA Safety Series No. 6 in order to help comprehension of the regulatory standards and to promote compliance, public acceptance and further development of the Regulations. The document also reflects corrections and changes implemented by the 1986 Supplement to the Regulations for the Safe Transport of Radioactive Material. The intent of the document is to show why certain provisions of Safety Series No. 6 exist, why they are so formed (including any relevant history) and the rationale behind the provisions. Definitions are presented, basic principles established, activity and fissile material limits as well as computational techniques are presented. The detailed requirements (the latter sections are built on this information) concern: shipping and storage, material packagings and packages which govern design. Test requirements are provided. Approval and administrative requirements are stated. Heavy emphasis is placed on providing safety through design. It contains the cornerstone of the basic requirements for packagings, packages and material-related aspects.

  14. Loss-of-coolant accident test series TC-1 experiment operating specifications

    International Nuclear Information System (INIS)

    Yackle, T.R.

    1979-09-01

    The purpose of this document is to specify the experiment operating procedure for the test series TC-1. The effects of externally mounted cladding thermocouples on the fuel rod thermal behavior during LOCA blowdown and reflood cycles will be investigated in the test. Potential thermocouple effects include: (a) delayed DNB, (b) momentary cladding rewets following DNB, (c) premature cladding rewet during a blowdown two-phase slug period, and (d) early cladding rewet during reflood. The two-phase slug period will be controlled by momentarily opening the hot leg valve. The slug will consist of lower plenum liquid that is sent through the flow shrouds and will be designed to quench the fuel rods at a rate that is similar to the slug experienced early in the LOFT L2-2 and L2-3 tests

  15. 76 FR 12719 - Safe Schools/Healthy Students Program; Office of Safe and Drug-Free Schools; Safe Schools/Healthy...

    Science.gov (United States)

    2011-03-08

    ... DEPARTMENT OF EDUCATION Safe Schools/Healthy Students Program; Office of Safe and Drug- Free Schools; Safe Schools/Healthy Students Program; Catalog of Federal Domestic Assistance (CFDA) Numbers: 84... priorities, requirements, and definitions under the Safe Schools/Healthy Students (SS/HS) program. Since...

  16. Gas Generation from K East Basin Sludges - Series II Testing

    International Nuclear Information System (INIS)

    Bryan, Samuel A.; Delegard, Calvin H.; Schmidt, Andrew J.; Sell, Rachel L.; Silvers, Kurt L.; Gano, Susan R.; Thornton, Brenda M.

    2001-01-01

    This report describes work to examine the gas generation behavior of actual K East (KE) Basin floor, pit and canister sludge. Mixed and unmixed and fractionated KE canister sludge were tested, along with floor and pit sludges from areas in the KE Basin not previously sampled. The first report in this series focused on gas generation from KE floor and canister sludge collected using a consolidated sampling technique. The third report will present results of gas generation testing of irradiated uranium fuel fragments with and without sludge addition. The path forward for management of the K Basin Sludge is to retrieve, ship, and store the sludge at T Plant until final processing at some future date. Gas generation will impact the designs and costs of systems associated with retrieval, transportation and storage of sludge

  17. Explanatory material for the IAEA regulations for the safe transport of radioactive material (1985 edition). 2. ed. (as amended 1990)

    International Nuclear Information System (INIS)

    1990-01-01

    This publication is an updated version of the Second Edition of the Explanatory Material for the IAEA Regulations for the Safe Transport of Radioactive Material (1985 Edition) and replaces all previous versions of Safety Series No. 7. This publication includes the changes to Safety Series No. 7 contained in the Regulations for the Safe Transport of Radioactive Material, 1985 Edition, Supplement 1988, as well as modifications adopted by the Review Panel that was convened in Vienna, 10-14 July 1989. For the convenience of the user, the old Safety Series style adopted in the original publication has been retained, although the old style has now been superseded by a new one, affecting the structure, the format and the cover of the Safety Series. It should be noted, however, that future editions will be published in the new style.

  18. Growing pains : how drug testing keeps workers and assets safe in a booming oil patch

    Energy Technology Data Exchange (ETDEWEB)

    Paulgaard, T.S.

    2006-06-15

    Drug abuse has become a subject of concern to the oil and gas industry, where mistakes in the operation of large machines can result in injury, death and the loss of millions of dollars. Pre-employment urine tests are becoming standard procedure in the oil field. Many supervisors refuse to let employees start work without a clear test. Urine samples are tested for the presence of cannabis, cocaine, opiates, amphetamines and phencyclidine. When a worker is injured or killed on the job, or after an uncommon error that causes significant damage, all parties involved are tested as soon as possible and a receipt of the results are expedited. The Alberta Human Rights and Citizenship Commission is now addressing the issue of drug testing, and has ascertained that drug and alcohol testing are only allowable in certain circumstances, and that it is discriminatory to test potential or existing employees for drug and alcohol use if the testing is not reasonable or justifiable. They have also suggested that there is a duty to accommodate persons with disabilities in the workplace. Drug and alcohol dependency fall within the meaning of disabled. Under the Construction Owner's Association of Alberta's Canadian Model for a Safe Workplace, testing must work in concert with treatment. Current employees are directed to seek help via an employee assistant plan. Workers and supervisors report that drug use is rampant in work camps. Industry-wide, fail rates for those who take part in drug testing are quoted by experts as ranging from between 2 to 14 per cent. 2 figs.

  19. Growing pains : how drug testing keeps workers and assets safe in a booming oil patch

    Energy Technology Data Exchange (ETDEWEB)

    Paulgaard, T S

    2006-06-15

    Drug abuse has become a subject of concern to the oil and gas industry, where mistakes in the operation of large machines can result in injury, death and the loss of millions of dollars. Pre-employment urine tests are becoming standard procedure in the oil field. Many supervisors refuse to let employees start work without a clear test. Urine samples are tested for the presence of cannabis, cocaine, opiates, amphetamines and phencyclidine. When a worker is injured or killed on the job, or after an uncommon error that causes significant damage, all parties involved are tested as soon as possible and a receipt of the results are expedited. The Alberta Human Rights and Citizenship Commission is now addressing the issue of drug testing, and has ascertained that drug and alcohol testing are only allowable in certain circumstances, and that it is discriminatory to test potential or existing employees for drug and alcohol use if the testing is not reasonable or justifiable. They have also suggested that there is a duty to accommodate persons with disabilities in the workplace. Drug and alcohol dependency fall within the meaning of disabled. Under the Construction Owner's Association of Alberta's Canadian Model for a Safe Workplace, testing must work in concert with treatment. Current employees are directed to seek help via an employee assistant plan. Workers and supervisors report that drug use is rampant in work camps. Industry-wide, fail rates for those who take part in drug testing are quoted by experts as ranging from between 2 to 14 per cent. 2 figs.

  20. Recommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series.

    Science.gov (United States)

    Bruze, Magnus; Andersen, Klaus Ejner; Goossens, An

    2008-03-01

    The currently used fragrance mix in the European baseline patch test series (baseline series) fails to detect a substantial number of clinically relevant fragrance allergies. To investigate whether it is justified to include hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) and fragrance mix 2 containing hydroxyisohexyl 3-cyclohexene carboxaldehyde, citral, farnesol, coumarin, citronellol, and alpha-hexyl cinnamal in the European baseline patch test series. Survey of the literature on reported frequencies of contact allergy and allergic contact dermatitis from fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) as well as reported results of experimental provocation test. Fragrance mix 2 has been demonstrated to be a useful additional marker of fragrance allergy with contact allergy rates up to 5% when included in various national baseline patch test series. Of the fragrance substances present in fragrance mix 2, hydroxyisohexyl 3-cyclohexene carboxaldehyde is the most common sensitizer. Contact allergy rates between 1.5% and 3% have been reported for hydroxyisohexyl 3-cyclohexene carboxaldehyde in petrolatum (pet.) at 5% from various European centres when tested in consecutive dermatitis patients. From 2008, pet. preparations of fragrance mix 2 at 14% w/w (5.6 mg/cm(2)) and hydroxyisohexyl 3-cyclohexene carboxaldehyde at 5% w/w (2.0 mg/cm(2)) are recommended for inclusion in the baseline series. With the Finn Chamber technique, a dose of 20 mg pet. preparation is recommended. Whenever there is a positive reaction to fragrance mix 2, additional patch testing with the 6 ingredients, 5 if there are simultaneous positive reactions to hydroxyisohexyl 3-cyclohexene carboxaldehyde and fragrance mix 2, is recommended.

  1. Safe transport of radioactive material

    International Nuclear Information System (INIS)

    1990-01-01

    Recently the Agency redefined its policy for education and training in radiation safety. The emphasis is now on long-term strategic planning of general education and training programmes. In line with this general policy the Agency's Standing Advisory Group for the Safe Transport of Radioactive Material (SAGSTRAM) in its 7th meeting (April 1989) agreed that increased training activity should be deployed in the area of transport. SAGSTRAM specifically recommended the development of a standard training programme on this subject area, including audio-visual aids, in order to assist Member States in the implementation of the Agency's Regulations for the Safe Transport of Radioactive Material. This training programme should be substantiated by a biennial training course which is thought to be held either as an Interregional or a Regional Course depending on demand. This training manual, issued as a first publication in the Training Course Series, represents the basic text material for future training courses in transport safety. The topic areas covered by this training manual and most of the texts have been developed from the course material used for the 1987 Bristol Interregional Course on Transport Safety. The training manual is intended to give guidance to the lecturers of a course and will be provided to the participants for retention. Refs, figs and tabs

  2. Cool and Safe: Multiplicity in Safe Innovation at Unilever

    Science.gov (United States)

    Penders, Bart

    2011-01-01

    This article presents the making of a safe innovation: the application of ice structuring protein (ISP) in edible ices. It argues that safety is not the absence of risk but is an active accomplishment; innovations are not "made safe afterward" but "safe innovations are made". Furthermore, there are multiple safeties to be accomplished in the…

  3. ACER Tests of Basic Skills: Aspects of Literacy, Aspects of Numercy. Teacher's Manual. Blue Series 6.

    Science.gov (United States)

    Lokan, Jan; And Others

    Developed for the Basic Skills Testing Program (BSTP) in New South Wales, Australia, this teacher's manual describes the ACER (Australian Council for Educational Research) Tests of Basic Skills. The two tests in this series, Aspects of Literacy and Aspects of Numeracy, were administered statewide by government school classroom teachers in August,…

  4. The Impact of Time-Series Diagnostic Tests on the Writing Ability of Iranian EFL Learners

    Science.gov (United States)

    Atashgahi, Bahareh Molazem

    2014-01-01

    This study aimed to show whether administering a battery of time-series diagnostic tests (screening) has any impact on Iranian EFL learners' writing ability. The study was conducted on the intermediate EFL learners at Islamic Azad University North Tehran branch. The researcher administered a homogenizing test in order to exclude the exceptional…

  5. Using exogenous variables in testing for monotonic trends in hydrologic time series

    Science.gov (United States)

    Alley, William M.

    1988-01-01

    One approach that has been used in performing a nonparametric test for monotonic trend in a hydrologic time series consists of a two-stage analysis. First, a regression equation is estimated for the variable being tested as a function of an exogenous variable. A nonparametric trend test such as the Kendall test is then performed on the residuals from the equation. By analogy to stagewise regression and through Monte Carlo experiments, it is demonstrated that this approach will tend to underestimate the magnitude of the trend and to result in some loss in power as a result of ignoring the interaction between the exogenous variable and time. An alternative approach, referred to as the adjusted variable Kendall test, is demonstrated to generally have increased statistical power and to provide more reliable estimates of the trend slope. In addition, the utility of including an exogenous variable in a trend test is examined under selected conditions.

  6. Sensor response monitoring in pressurized water reactors using time series modeling

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Kerlin, T.W.

    1978-01-01

    Random data analysis in nuclear power reactors for purposes of process surveillance, pattern recognition and monitoring of temperature, pressure, flow and neutron sensors has gained increasing attention in view of their potential for helping to ensure safe plant operation. In this study, application of autoregressive moving-average (ARMA) time series modeling for monitoring temperature sensor response characteristrics is presented. The ARMA model is used to estimate the step and ramp response of the sensors and the related time constant and ramp delay time. The ARMA parameters are estimated by a two-stage algorithm in the spectral domain. Results of sensor testing for an operating pressurized water reactor are presented. 16 refs

  7. Test of 6-inch-thick pressure vessels. Series 2. Intermediate test vessels V-3, V-4, and V-6

    International Nuclear Information System (INIS)

    Bryan, R.H.; Merkle, J.G.; Raftenberg, M.N.; Robinson, G.C.; Smith, J.E.

    1975-11-01

    The second series of intermediate vessel tests were crack initiation fracture tests of 6-in.-thick 39-in.-OD steel vessels with sharp surface flaws approximately 2 1 / 2 in. deep by 8 in. long in the longitudinal weld seams of the test cylinders. Fracture was initiated by means of hydraulic pressurization. One vessel was tested at each of three temperatures: 75, 130, and 190 0 F. Pretest analyses were made to predict the failure pressures and strains. Fracture toughness data obtained by equivalent-energy analysis of precracked Charpy-V tests and compact-tension specimen tests were used in the fracture analyses. The vessels behaved generally as had been expected. Posttest fracture analyses were also performed for each vessel. Detailed discussions of the fracture analysis methods developed in support of the vessel tests described are included. 34 references

  8. Open-source Software for Demand Forecasting of Clinical Laboratory Test Volumes Using Time-series Analysis.

    Science.gov (United States)

    Mohammed, Emad A; Naugler, Christopher

    2017-01-01

    Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. This tool will allow anyone with historic test volume data to model future demand.

  9. Open-source software for demand forecasting of clinical laboratory test volumes using time-series analysis

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2017-01-01

    Full Text Available Background: Demand forecasting is the area of predictive analytics devoted to predicting future volumes of services or consumables. Fair understanding and estimation of how demand will vary facilitates the optimal utilization of resources. In a medical laboratory, accurate forecasting of future demand, that is, test volumes, can increase efficiency and facilitate long-term laboratory planning. Importantly, in an era of utilization management initiatives, accurately predicted volumes compared to the realized test volumes can form a precise way to evaluate utilization management initiatives. Laboratory test volumes are often highly amenable to forecasting by time-series models; however, the statistical software needed to do this is generally either expensive or highly technical. Method: In this paper, we describe an open-source web-based software tool for time-series forecasting and explain how to use it as a demand forecasting tool in clinical laboratories to estimate test volumes. Results: This tool has three different models, that is, Holt-Winters multiplicative, Holt-Winters additive, and simple linear regression. Moreover, these models are ranked and the best one is highlighted. Conclusion: This tool will allow anyone with historic test volume data to model future demand.

  10. Perseus B Taxi Tests in Preparation for a New Series of Flight Tests

    Science.gov (United States)

    1998-01-01

    The Perseus B remotely piloted aircraft taxis on the runway at Edwards Air Force Base, California, before a series of development flights at NASA's Dryden flight Research Center. The Perseus B is the latest of three versions of the Perseus design developed by Aurora Flight Sciences under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) program. Perseus B is a remotely piloted aircraft developed as a design-performance testbed under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. Perseus is one of several flight vehicles involved in the ERAST project. A piston engine, propeller-powered aircraft, Perseus was designed and built by Aurora Flight Sciences Corporation, Manassas, Virginia. The objectives of Perseus B's ERAST flight tests have been to reach and maintain horizontal flight above altitudes of 60,000 feet and demonstrate the capability to fly missions lasting from 8 to 24 hours, depending on payload and altitude requirements. The Perseus B aircraft established an unofficial altitude record for a single-engine, propeller-driven, remotely piloted aircraft on June 27, 1998. It reached an altitude of 60,280 feet. In 1999, several modifications were made to the Perseus aircraft including engine, avionics, and flight-control-system improvements. These improvements were evaluated in a series of operational readiness and test missions at the Dryden Flight Research Center, Edwards, California. Perseus is a high-wing monoplane with a conventional tail design. Its narrow, straight, high-aspect-ratio wing is mounted atop the fuselage. The aircraft is pusher-designed with the propeller mounted in the rear. This design allows for interchangeable scientific-instrument payloads to be placed in the forward fuselage. The design also allows for unobstructed airflow to the sensors and other devices mounted in the payload compartment. The Perseus B that underwent test and development in 1999 was the third generation of the Perseus

  11. Boxing training for patients with Parkinson disease: a case series.

    Science.gov (United States)

    Combs, Stephanie A; Diehl, M Dyer; Staples, William H; Conn, Lindsay; Davis, Kendra; Lewis, Nicole; Schaneman, Katie

    2011-01-01

    A nontraditional form of exercise recently applied for patients with Parkinson disease (PD) is boxing training. The primary purpose of this case series is to describe the effects of disease severity and duration of boxing training (short term and long term) on changes in balance, mobility, and quality of life for patients with mild or moderate to severe PD. The feasibility and safety of the boxing training program also were assessed. Six patients with idiopathic PD attended 24 to 36 boxing training sessions for 12 weeks, with the option of continuing the training for an additional 24 weeks (a seventh patient attended sessions for only 4 weeks). The 90-minute sessions included boxing drills and traditional stretching, strengthening, and endurance exercises. Outcomes were tested at the baseline and after 12, 24, and 36 weeks of boxing sessions (12-, 24-, and 36-week tests). The outcome measures were the Functional Reach Test, Berg Balance Scale, Activities-specific Balance Confidence Scale, Timed "Up & Go" Test, Six-Minute Walk Test, gait speed, cadence, stride length, step width, activities of daily living and motor examination subscales of the Unified Parkinson Disease Rating Scale, and Parkinson Disease Quality of Life Scale. Six patients completed all phases of the case series, showed improvements on at least 5 of the 12 outcome measures over the baseline at the 12-week test, and showed continued improvements at the 24- and 36-week tests. Patients with mild PD typically showed improvements earlier than those with moderate to severe PD. Despite the progressive nature of PD, the patients in this case series showed short-term and long-term improvements in balance, gait, activities of daily living, and quality of life after the boxing training program. A longer duration of training was necessary for patients with moderate to severe PD to show maximal training outcomes. The boxing training program was feasible and safe for these patients with PD.

  12. Standard test method for exfoliation corrosion susceptibility in 2XXX and 7XXX Series Aluminum Alloys (EXCO Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method covers a procedure for constant immersion exfoliation corrosion (EXCO) testing of high-strength 2XXX and 7XXX series aluminum alloys. Note 1—This test method was originally developed for research and development purposes; however, it is referenced, in specific material specifications, as applicable for evaluating production material (refer to Section 14 on Precision and Bias). 1.2 This test method applies to all wrought products such as sheet, plate, extrusions, and forgings produced from conventional ingot metallurgy process. 1.3 This test method can be used with any form of specimen or part that can be immersed in the test solution. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  13. Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Best, Lawrence Mj; Tanguay, Cynthia; Lennan, Elaine; Korva, Mika; Bussières, Jean-François

    2018-03-27

    between CSTD and control groups in the pharmacy areas or patient-care areas.None of the studies report on atmospheric contamination, blood tests, or other measures of exposure to infusional hazardous drugs such as urine mutagenicity, chromosomal aberrations, sister chromatid exchanges, or micronuclei induction.None of the studies report short-term health benefits such as reduction in skin rashes, medium-term reproductive health benefits such as fertility and parity, or long-term health benefits related to the development of any type of cancer or adverse events.Five studies (six hospitals) report the potential cost savings through the use of CSTD. The studies used different methods of calculating the costs, and the results were not reported in a format that could be pooled via meta-analysis. There is significant variability between the studies in terms of whether CSTD resulted in cost savings (the point estimates of the average potential cost savings ranged from (2017) USD -642,656 to (2017) USD 221,818). There is currently no evidence to support or refute the routine use of closed-system drug transfer devices in addition to safe handling of infusional hazardous drugs, as there is no evidence of differences in exposure or financial benefits between CSTD plus safe handling versus safe handling alone (very low-quality evidence). None of the studies report health benefits.Well-designed multicentre randomised controlled trials may be feasible depending upon the proportion of people with exposure. The next best study design is interrupted time-series. This design is likely to provide a better estimate than uncontrolled before-after studies or cross-sectional studies. Future studies may involve other alternate ways of reducing exposure in addition to safe handling as one intervention group in a multi-arm parallel design or factorial design trial. Future studies should have designs that decrease the risk of bias and enable measurement of direct health benefits in addition to

  14. Lyral has been included in the patch test standard series in Germany.

    Science.gov (United States)

    Geier, Johannes; Brasch, Jochen; Schnuch, Axel; Lessmann, Holger; Pirker, Claudia; Frosch, Peter J

    2002-05-01

    Lyral 5% pet. was tested in 3245 consecutive patch test patients in 20 departments of dermatology in order (i) to check the diagnostic quality of this patch test preparation, (ii) to examine concomitant reactions to Lyral and fragrance mix (FM), and (iii) to assess the frequency of contact allergy to Lyral in an unselected patch test population of German dermatological clinics. 62 patients reacted to Lyral, i.e. 1.9%. One third of the positive reactions were + + and + + +. The reaction index was 0.27. Thus, the test preparation can be regarded a good diagnostic tool. Lyral and fragrance mix (FM) were tested in parallel in 3185 patients. Of these, 300 (9.4%) reacted to FM, and 59 (1.9%) to Lyral. In 40 patients, positive reactions to both occurred, which is 13.3% of those reacting to FM, and 67.8% of those reacting to Lyral. So the concordance of positive test reactions to Lyral and FM was only slight. Based on these results, the German Contact Dermatitis Research Group (DKG) decided to add Lyral 5% pet. to the standard series.

  15. Penicillin skin testing is a safe and effective tool for evaluating penicillin allergy in the pediatric population.

    Science.gov (United States)

    Fox, Stephanie J; Park, Miguel A

    2014-01-01

    Penicillin skin testing has been validated in the evaluation of adult patients with penicillin allergy. However, the commercially available benzylpenicilloyl polylysine (Pre-Pen) is not indicated in the pediatric population. Moreover, the safety and validity of penicillin skin testing in the pediatric population has not been well studied. We describe the safety and validity of penicillin skin testing in the evaluation of children with a history of penicillin allergy. Children (penicillin allergy were evaluated with penicillin skin tests and were reviewed for basic demographics, penicillin skin test results, adverse drug reaction to penicillin after penicillin skin test, and adverse reaction to penicillin skin test. By using the χ(2) test, we compared the differences in the proportion of children and adults with a positive penicillin skin test. P value (penicillin skin testing; 703 of 778 patients had a negative penicillin skin test (90.4%), 66 had a positive test (8.5%), and 9 had an equivocal test (1.1%). Children were more likely to have a positive penicillin skin test (P penicillin skin test (52%) were challenged with penicillin, and 14 of 369 patients (3.8%) had an adverse drug reaction. No adverse reactions to penicillin skin testing were observed. Penicillin skin testing was safe and effective in the evaluation of children with a history of penicillin allergy. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  16. Integrated Test and Evaluation Flight Test 3 Flight Test Plan

    Science.gov (United States)

    Marston, Michael Lawrence

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  17. Physician discretion is safe and may lower stress test utilization in emergency department chest pain unit patients.

    Science.gov (United States)

    Napoli, Anthony M; Arrighi, James A; Siket, Matthew S; Gibbs, Frantz J

    2012-03-01

    Chest pain unit (CPU) observation with defined stress utilization protocols is a common management option for low-risk emergency department patients. We sought to evaluate the safety of a joint emergency medicine and cardiology staffed CPU. Prospective observational trial of consecutive patients admitted to an emergency department CPU was conducted. A standard 6-hour observation protocol was followed by cardiology consultation and stress utilization largely at their discretion. Included patients were at low/intermediate risk by the American Heart Association, had nondiagnostic electrocardiograms, and a normal initial troponin. Excluded patients were those with an acute comorbidity, age >75, and a history of coronary artery disease, or had a coexistent problem restricting 24-hour observation. Primary outcome was 30-day major adverse cardiovascular events-defined as death, nonfatal acute myocardial infarction, revascularization, or out-of-hospital cardiac arrest. A total of 1063 patients were enrolled over 8 months. The mean age of the patients was 52.8 ± 11.8 years, and 51% (95% confidence interval [CI], 48-54) were female. The mean thrombolysis in myocardial infarction and Diamond & Forrester scores were 0.6% (95% CI, 0.51-0.62) and 33% (95% CI, 31-35), respectively. In all, 51% (95% CI, 48-54) received stress testing (52% nuclear stress, 39% stress echocardiogram, 5% exercise, 4% other). In all, 0.9% patients (n = 10, 95% CI, 0.4-1.5) were diagnosed with a non-ST elevation myocardial infarction and 2.2% (n = 23, 95% CI, 1.3-3) with acute coronary syndrome. There was 1 (95% CI, 0%-0.3%) case of a 30-day major adverse cardiovascular events. The 51% stress test utilization rate was less than the range reported in previous CPU studies (P < 0.05). Joint emergency medicine and cardiology management of patients within a CPU protocol is safe, efficacious, and may safely reduce stress testing rates.

  18. The SafeCOP ECSEL Project: Safe Cooperating Cyber-Physical Systems Using Wireless Communication

    DEFF Research Database (Denmark)

    Pop, Paul; Scholle, Detlef; Hansson, Hans

    2016-01-01

    This paper presents an overview of the ECSEL project entitled "Safe Cooperating Cyber-Physical Systems using Wireless Communication" (SafeCOP), which runs during the period 2016 -- 2019. SafeCOP targets safety-related Cooperating Cyber-Physical Systems (CO-CPS) characterised by use of wireless...... detection of abnormal behaviour, triggering if needed a safe degraded mode. SafeCOP will also develop methods and tools, which will be used to produce safety assurance evidence needed to certify cooperative functions. SafeCOP will extend current wireless technologies to ensure safe and secure cooperation...

  19. Ecotoxicological test systems proceedings of a series of workshops

    Energy Technology Data Exchange (ETDEWEB)

    Hammons, A.S. (ed.)

    1981-06-01

    A series of six workshops was conducted by the Environmental Sciences Division, Oak Ridge National Laboratory, to identify laboratory methods and data evaluation techniques for predicting the environmental effects of chemical substances. Methods were evaluated for their potential for standardization and for use in the ecological hazard and risk assessment processes under the Toxic Substances Control Act. The workshops addressed assessment and policy requirements of multispecies toxicology test procedures, mathematical models useful in hazard and risk assessments, and methods for measuring effects of chemicals on terrestrial and aquatic population interactions and ecosystem properties. The workshops were primarily used as a mechanism to gather information about research in progress. This information was part of the data base used to prepare a critical review of laboratory methods for ecological toxicology.

  20. Ecotoxicological test systems proceedings of a series of workshops

    International Nuclear Information System (INIS)

    Hammons, A.S.

    1981-06-01

    A series of six workshops was conducted by the Environmental Sciences Division, Oak Ridge National Laboratory, to identify laboratory methods and data evaluation techniques for predicting the environmental effects of chemical substances. Methods were evaluated for their potential for standardization and for use in the ecological hazard and risk assessment processes under the Toxic Substances Control Act. The workshops addressed assessment and policy requirements of multispecies toxicology test procedures, mathematical models useful in hazard and risk assessments, and methods for measuring effects of chemicals on terrestrial and aquatic population interactions and ecosystem properties. The workshops were primarily used as a mechanism to gather information about research in progress. This information was part of the data base used to prepare a critical review of laboratory methods for ecological toxicology

  1. Safe Kids Worldwide

    Science.gov (United States)

    ... Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Search Menu Why It Matters Who We Are What We Do Find Your Safe Kids Safe Kids Day Main menu Keeping All Kids Safe Safety Tips Get Involved 4 Star Charity Donate Text Burns and Scalds 4 tips ...

  2. Criteria for the spreading of oxide melts: Test series miniKATS-1 to -5

    International Nuclear Information System (INIS)

    Eppinger, B.; Fieg, G.; Massier, H.; Schuetz, W.; Stegmaier, U.; Stern, G.

    2001-09-01

    In a long series of larger spreading tests with high temperature oxide melts (KATS tests) many parameters have been varied which are influencing the spreading behaviour (viscosity, pouring rate, substratum of spreading surface, presence of water). In spite of an extensive instrumentation using different thermocouples, an infrared camera and several video cameras, only in very few cases the behaviour of the melt front at the very moment of immobilization could be detected in detail. Therefore in the additional miniKATS series five small scale (5 kg) spreading tests with oxide melts have been conducted to investigate the mechanical properties of the spreading front in the moment of immobilization. It turned out that in all cases the bulk of the melt at this moment was still liquid at a temperature close to the initial one. Depending on the initial melt properties two distinct phenomena have been observed which control the immobilization of the melt: the first phenomena is the crust formation at the surface, the crusts at the bottom combined with the crust at the surface of the melt. In the other case the whole melt front was still above the liquid temperature at the moment of immobilization. Here the surface tension was controlling the spreading, it was in balance with the driving gravitational force. In none of the test bulk freezing has been detected. (orig.)

  3. Report of consultants to the IAEA on requirements for the safe transport of low hazard radioactive materials

    International Nuclear Information System (INIS)

    Collin, W.; Grenier, M.; Hopkins, D.

    1982-01-01

    In the present paper changes are recommmended to certain definitions given in the 2nd draft revision of the IAEA 'regulations for the safe transport of radioactive materials (safety series no. 6)'. (orig./RW)

  4. Combined in vivo and in vitro approach for the characterization of penicillin-specific polyclonal lymphocyte reactivity: tolerance tests with safe penicillins instead of challenge with culprit drugs.

    Science.gov (United States)

    Sachs, B; Al Masaoudi, T; Merk, H F; Erdmann, S

    2004-10-01

    Amino-penicillins are a major cause of delayed-type reactions to penicillins. The aim of this study was to establish a diagnostic approach for the characterization of the individual penicillin-specific polyclonal lymphocyte reactivity in order to detect side chain-specific sensitization to amino-penicillins. Patients can then be advised to undergo a tolerance test with safe penicillins instead of provocation with culprit penicillins for confirmation of penicillin allergy. We investigated penicillin-specific polyclonal lymphocyte reactivity in nine patients with delayed-type reactions to amino-penicillins by a combined in vivo (patch, prick and intracutaneous tests with delayed readings) and in vitro (lymphocyte transformation test, LTT) approach. A combination of LTT and skin tests improved the sensitivity for the characterization of penicillin-specific polyclonal lymphocyte reactivity and allowed the detection of three different patterns of lymphocyte reactivity. Four patients showed a side chain-specific sensitization to amino-penicillins in vivo and in vitro and were advised to undergo tolerance tests with safe penicillins. Two patients agreed and were exposed to parenteral benzyl-penicillin and oral phenoxymethyl-penicillin which they tolerated without complications. These data suggest that a combined in vivo and in vitro approach is helpful for the detection of side chain-specific sensitization to amino-penicillins. Patients with such sensitization are very likely to tolerate safe penicillins, thereby expanding their therapeutic options when antibiotic treatment is required.

  5. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU II card for Leak Detector Use Acceptance Test Procedure

    International Nuclear Information System (INIS)

    SMITH, S.G.

    1999-01-01

    The following Acceptance Test Procedure was written to test the ENRAF series 854 ATG with SPU II card prior to installation in the Tank Farms. The procedure sets various parameters and verifies the gauge and alarms functionality

  6. "Same Room, Safe Place".

    Science.gov (United States)

    Keene Woods, Nikki

    2017-04-01

    There are many different professional stances on safe sleep and then there is the reality of caring for a newborn. There is a debate among professionals regarding safe sleep recommendations. The continum of recommendations vary from the American Academy of Pediatrics (AAP) Safe Sleep Guidelines to the bed-sharing recommendations from the Mother-Baby Behavioral Sleep Laboratory. The lack of consistent and uniform safe sleep recommendations from health professionals has been confusing for families but has more recently raised a real professional ethical dilemma. Despite years of focused safe sleep community education and interventions, sleep-related infant deaths are on the rise in many communities. This commentary calls for a united safe sleep message from all health professionals to improve health for mothers and infants most at-risk, "Same Room, Safe Place."

  7. CPAS Preflight Drop Test Analysis Process

    Science.gov (United States)

    Englert, Megan E.; Bledsoe, Kristin J.; Romero, Leah M.

    2015-01-01

    Throughout the Capsule Parachute Assembly System (CPAS) drop test program, the CPAS Analysis Team has developed a simulation and analysis process to support drop test planning and execution. This process includes multiple phases focused on developing test simulations and communicating results to all groups involved in the drop test. CPAS Engineering Development Unit (EDU) series drop test planning begins with the development of a basic operational concept for each test. Trajectory simulation tools include the Flight Analysis and Simulation Tool (FAST) for single bodies, and the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulation for the mated vehicle. Results are communicated to the team at the Test Configuration Review (TCR) and Test Readiness Review (TRR), as well as at Analysis Integrated Product Team (IPT) meetings in earlier and intermediate phases of the pre-test planning. The ability to plan and communicate efficiently with rapidly changing objectives and tight schedule constraints is a necessity for safe and successful drop tests.

  8. ENRAF Series 854 Advanced Technology Gauge (ATG) with SPU ll Card for Leak Detector Use Acceptance Test Procedure

    International Nuclear Information System (INIS)

    SMITH, S.G.

    1999-01-01

    The following Acceptance Test Procedure was written to test the Enraf Series 854 ATG with SPU-II card prior to installation in the Tank Farms. The procedure sets various parameters and verifies the gauge and the alarms functionality

  9. Design of a safe cylindrical lithium/thionyl chloride cell

    Science.gov (United States)

    Johnson, D. H.; Ayers, A. D.; Zupancic, R. L.; Alberto, V. S.; Bailey, J. C.

    1984-05-01

    Cell design criteria have been established which can result in a safe lithium/thionyl chloride cell. A cell vent, a low area internal anode design, cell balance and composition of the cathode-electrolyte solution have been found to be important factors in the design of a safe cell. In addition to routine testing, both undischarged and discharged cells have been subjected to electrical abuse, environmental abuse and mechanical abuse without disassembly.

  10. LACK OF AWARENESS ABOUT SAFE BLOOD IN PAKISTANI POPULATION

    Directory of Open Access Journals (Sweden)

    Muhammad Usman

    2014-12-01

    Full Text Available Blood transfusion is a life saving procedure in various transfusion-dependent life threatening conditions and donation of safe blood is a prerequisite for achieving this goal. This study was designed to evaluate the awareness regarding “safe blood” in Pakistani population. This study was conducted at a large scale through a population survey. The test population was divided into two groups i.e. general population and students. The Performa was designed for a general and student population and included 20 questions related to awareness of safe blood. A total of 4900 individuals belonging to different ethnic groups were included in this population survey. Results of social survey were analyzed by using Usman and Moin awareness chart. Results of this study revealed profound unawareness about safe blood in Pakistani population. This study found lack of awareness about safe blood as a major factor that is playing a vital role in the propagation of blood borne diseases in Pakistan. To secure the recipients from blood borne complications through blood donation, it is necessary to create effective awareness about safe blood in Pakistani population.

  11. Safety test results of lithium-thionyl chloride wound-type cells

    Science.gov (United States)

    Vallin, D.; Broussely, M.

    1989-05-01

    Increase in the use of spirally-wound, lithium-thionyl chloride cells is currently limited because of unsafe incidents which have been reported during the early stage of development of this product. Today, it is believed that these cells are safe over a wide range of operating conditions if properly designed. The paper describes the external and internal SAFT design of Li-SOCl2LSH series cells, as well as the results of safety tests.

  12. SYBR safeTM efficiently replaces ethidium bromide in Aspergillus fumigatus gene disruption.

    Science.gov (United States)

    Canela, H M S; Takami, L A; Ferreira, M E S

    2017-02-08

    Invasive aspergillosis is a disease responsible for high mortality rates, caused mainly by Aspergillus fumigatus. The available drugs are limited and this disease continues to occur at an unacceptable frequency. Gene disruption is essential in the search for new drug targets. An efficient protocol for A. fumigatus gene disruption was described but it requires ethidium bromide, a genotoxic agent, for DNA staining. Therefore, the present study tested SYBR safe TM , a non-genotoxic DNA stain, in A. fumigatus gene disruption protocol. The chosen gene was cipC, which has already been disrupted successfully in our laboratory. A deletion cassette was constructed in Saccharomyces cerevisiae and used in A. fumigatus transformation. There was no statistical difference between the tested DNA stains. The success rate of S. cerevisiae transformation was 63.3% for ethidium bromide and 70% for SYBR safe TM . For A. fumigatus gene disruption, the success rate for ethidium bromide was 100 and 97% for SYBR safe TM . In conclusion, SYBR safe TM efficiently replaced ethidium bromide, making this dye a safe and efficient alternative for DNA staining in A. fumigatus gene disruption.

  13. DroidSafe

    Science.gov (United States)

    2016-12-01

    Massachusetts Avenue, Build E19-750 Cambridge , MA 02139-4307 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS...Activity objects illustrating the challenges of points-to and information flow analysis...measure how many malicious flows Droid- Safe was able to detect). As these results illustrate , DroidSafe implements an analysis of unprece- dented

  14. Do Leadership Style, Unit Climate, and Safety Climate Contribute to Safe Medication Practices?

    Science.gov (United States)

    Farag, Amany; Tullai-McGuinness, Susan; Anthony, Mary K; Burant, Christopher

    2017-01-01

    This study aims at: examining if leadership style and unit climate predict safety climate; and testing the direct, indirect, and total effect of leadership style, unit climate, and safety climate on nurses' safe medication practices. The Institute of Medicine and nursing scholars propose that safety climate is a prerequisite to safety practices. However, there is limited empirical evidence about factors contributing to the development of safety climate and about the association with nurses' safe medication practices. This cross-sectional study used survey data from 246 RNs working in a Magnet® hospital. Leadership style and unit climate predicted 20% to 50% of variance on all safety climate dimensions. Model testing revealed the indirect impact of leadership style and unit climate on nurses' safe medication practices. Our hypothesized model explained small amount of the variance on nurses' safe medication practices. This finding suggests that nurses' safe medication practices are influenced by multiple contextual and personal factors that should be further examined.

  15. Changes in serial laboratory test results in snakebite patients: when can we safely exclude envenoming?

    Science.gov (United States)

    Ireland, Graham; Brown, Simon G A; Buckley, Nicholas A; Stormer, Jeff; Currie, Bart J; White, Julian; Spain, David; Isbister, Geoffrey K

    2010-09-06

    To determine which laboratory tests are first associated with severe envenoming after a snakebite, when (ie, how long after the bite) the test results become abnormal, and whether this can determine a safe observation period after suspected snakebite. Prospective cohort study of 478 patients with suspected or confirmed snakebite recruited to the Australian Snakebite Project from January 2002 to April 2009, who had at least three sets of laboratory test results and at least 12 hours of observation in hospital after the bite. Severe envenoming was defined as venom-induced consumption coagulopathy (VICC), myotoxicity, neurotoxicity or thrombotic microangiopathy. International normalised ratio (INR), activated partial thromboplastin time (aPTT), creatine kinase (CK) level, and neurological examination. There were 240 patients with severe envenoming, 75 with minor envenoming and 163 non-envenomed patients. Of 206 patients with VICC, 178 had an INR > 1.2 (abnormal) on admission, and the remaining 28 had an INR > 1.2 within 12 hours of the bite. Of 33 patients with myotoxicity, a combination of CK > 250 U/L and an abnormal aPTT identified all but two cases by 12 hours; one of these two was identified within 12 hours by leukocytosis. Nine cases of isolated neurotoxicity had a median time of onset after the bite of 4 hours (range, 35 min - 12 h). The combination of serial INR, aPTT and CK tests and repeated neurological examination identified 213 of 222 severe envenoming cases (96%) by 6 hours and 238 of 240 (99%) by 12 hours. Laboratory parameters (INR, aPTT and CK) and neurological reassessments identified nearly all severe envenoming cases within 12 hours of the bite, even in this conservative analysis that assumed normal test results if the test was not done.

  16. Safe havens in Europe

    DEFF Research Database (Denmark)

    Paldam, Martin

    2013-01-01

    Eleven safe havens exist in Europe providing offshore banking and low taxes. Ten of these states are very small while Switzerland is moderately small. All 11 countries are richer than their large neighbors. It is shown that causality is from small to safe haven to wealth, and that theoretically...... equilibriums are likely to exist where a certain regulation is substantially lower in a small country than in its big neighbor. This generates a large capital inflow to the safe havens. The pool of funds that may reach the safe havens is shown to be huge. It is far in excess of the absorptive capacity...... of the safe havens, but it still explains, why they are rich. Microstates offer a veil of anonymity to funds passing through, and Switzerland offers safe storage of funds....

  17. Test Series 3: seismic-fragility tests of naturally-aged Class 1E C and D LCU-13 battery cells

    International Nuclear Information System (INIS)

    Bonzon, L.L.; Hente, D.B.; Kukreti, B.M.; Schendel, J.; Tulk, J.D.; Janis, W.J.; Black, D.A.; Paulsen, G.D.; Aucoin, B.D.

    1985-03-01

    This report, the third in a test series of an extensive seismic research program, covers the testing of 10-year old lead-calcium C and D LCU-13 cells from the North Anna Nuclear Power Station operated by the Virginia Electric and Power Company. The C and D cells were tested in two configurations using a triaxial shake table: single-cell tests, both rigidly and loosely mounted; and multicell (three-cell) tests, mounted in a typical battery rack. A total of seven electrically active cells was used in the two different cell configurations. None of the seven cells failed in the first stage tests during the actual seismic test up to the 1.5 g ZPAs imposed. Subsequent discharge capacity tests showed that while these cells suffered some loss of discharge capacity, all cells could deliver the accepted standard of 80% of their rated electrical capacity for 3 hours. When two of the same cells were exposed to the second stage, higher g-level tests, both cells again provided instantaneous uninterrupted power. Subsequent capacity tests showed both of these cells to have capacities well below the accepted standard of 80%. Four of the cells were disassembled for examination and metallurgical analyses. The examination showed that all plates and separators were in very good condition

  18. Traveling Safely with Medicines

    Science.gov (United States)

    ... Medications Safely My Medicine List How to Administer Traveling Safely with Medicines Planes, trains, cars – even boats ... your trip, ask your pharmacist about how to travel safely with your medicines. Make sure that you ...

  19. Safety test results of lithium-thionyl chloride wound-type cells

    Energy Technology Data Exchange (ETDEWEB)

    Vallin, D.; Broussely, M. (British Columbia Univ., Vancouver (Canada))

    1989-05-01

    Increase in the use of spirally-wound, lithium-thionyl chloride cells is currently limited because of unsafe incidents which have been reported during the early stage of development of this product. Today, it is believed that these cells are safe over a wide range of operating conditions if properly designed. The paper describes the external and internal SAFT design of Li-SOCl2LSH series cells, as well as the results of safety tests. 6 refs.

  20. Test plan for long-term, low-temperature oxidation of spent fuel, Series 1

    International Nuclear Information System (INIS)

    Einziger, R.E.

    1986-06-01

    Preliminary studies indicated the need for more spent fuel oxidation data in order to determine the probable behavior of spent fuel in a tuff repository. Long-term, low-temperature testing was recommended in a comprehensive technical approach to: (1) confirm the findings of the short-term thermogravimetric analyses scoping experiments; (2) evaluate the effects of variables such as burnup, atmospheric moisture and fuel type on the oxidation rate; and (3) extend the oxidation data base ot representative repository temperatures and better define the temperature dependence of the operative oxidation mechanisms. This document presents the Series 1 test plan to study, on a large number of samples, the effects of atmospheric moisture and temperature on oxidation rate and phase formation. Tests will run for up to two years, use characterized fragmented, and pulverized fuel samples, cover a temperature range of 110 0 C to 175 0 C and be conducted with an atmospheric moisture content rangeing from 0 C to approx. 80 0 C dew point. After testing, the samples will be examined and made available for leaching testing

  1. Reactive, Safe Navigation for Lunar and Planetary Robots

    Science.gov (United States)

    Utz, Hans; Ruland, Thomas

    2008-01-01

    When humans return to the moon, Astronauts will be accompanied by robotic helpers. Enabling robots to safely operate near astronauts on the lunar surface has the potential to significantly improve the efficiency of crew surface operations. Safely operating robots in close proximity to astronauts on the lunar surface requires reactive obstacle avoidance capabilities not available on existing planetary robots. In this paper we present work on safe, reactive navigation using a stereo based high-speed terrain analysis and obstacle avoidance system. Advances in the design of the algorithms allow it to run terrain analysis and obstacle avoidance algorithms at full frame rate (30Hz) on off the shelf hardware. The results of this analysis are fed into a fast, reactive path selection module, enforcing the safety of the chosen actions. The key components of the system are discussed and test results are presented.

  2. Image-Guided Transvesicular Drainage of Pelvic Fluid Collections: A Safe and Effective Alternative Approach.

    Science.gov (United States)

    Ayyagari, Raj R; Yeh, Cliff; Arici, Melih; Mojibian, Hamid; Reiner, Eric; Pollak, Jeffrey S

    2016-05-01

    To evaluate the safety and efficacy of percutaneous transvesicular drainage of pathologic pelvic fluid collections, a series of 15 patients who underwent 16 transvesicular drainage catheter placements was retrospectively reviewed. All patients had collections suspicious for infection that were posterior to the bladder or superior to the bladder behind loops of bowel, and were otherwise inaccessible. All 15 collections were percutaneously accessed via the bladder with standard drainage catheters. All collections resolved completely with no complications. Percutaneous transvesicular drainage was a safe and effective technique in this series, and can be considered when no direct percutaneous access routes are available. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  3. Power control of SAFE reactor using fuzzy logic

    International Nuclear Information System (INIS)

    Irvine, Claude

    2002-01-01

    Controlling the 100 kW SAFE (Safe Affordable Fission Engine) reactor consists of design and implementation of a fuzzy logic process control system to regulate dynamic variables related to nuclear system power. The first phase of development concentrates primarily on system power startup and regulation, maintaining core temperature equilibrium, and power profile matching. This paper discusses the experimental work performed in those areas. Nuclear core power from the fuel elements is simulated using resistive heating elements while heat rejection is processed by a series of heat pipes. Both axial and radial nuclear power distributions are determined from neuronic modeling codes. The axial temperature profile of the simulated core is matched to the nuclear power profile by varying the resistance of the heating elements. The SAFE model establishes radial temperature profile equivalence by establishing 32 control zones as the nodal coordinates. Control features also allow for slow warm up, since complete shutoff can occur in the heat pipes if heat-source temperatures drop/rise below a certain minimum value, depending on the specific fluid and gas combination in the heat pipe. The entire system is expected to be self-adaptive, i.e., capable of responding to long-range changes in the space environment. Particular attention in the development of the fuzzy logic algorithm shall ensure that the system process remains at set point, virtually eliminating overshoot on start-up and during in-process disturbances. The controller design will withstand harsh environments and applications where it might come in contact with water, corrosive chemicals, radiation fields, etc

  4. Patch and Prick Tests in Hand Eczema: Results of A Sixty Seven Patient Series

    Directory of Open Access Journals (Sweden)

    Bilge Fettahlıoğlu Karaman

    2017-12-01

    Full Text Available Objective: The patch and prick tests have a place in the management of patients with hand eczema. In this study, we investigated whether some of the clinical features patients with hand eczema could provide us with the predictability of skin test results. Methods: In Çukurova University Faculty of Medicine, 67 consecutive patients with hand eczema; evaluated in terms of duration of disease, morphology and severity. All of the patients were undergoes patch tested with the European Standard Series, and needle testing with routine aeroallergens. Results: Patch test with at least one allergen was positive in 46.3% of the patients; wheras this rate was 23.9% for prick test. The likelihood of having a contact sensitivity of patients complaining of hand eczema for at least three years was statistically more significant [odds ratio (OR 0.9]. Although statistically not significant, it is less likely to be sensitized to patients with keratotic and/or licheniform hand eczema (OR 0.3. The severity of hand eczema was not predictive of patch test, there was no indicator of needle test positivity. Conclusion: We strongly recommend patch testing in all patients with prolonged hand eczema.

  5. Executive Summary of Propulsion on the Orion Abort Flight-Test Vehicles

    Science.gov (United States)

    Jones, Daniel S.; Brooks, Syri J.; Barnes, Marvin W.; McCauley, Rachel J.; Wall, Terry M.; Reed, Brian D.; Duncan, C. Miguel

    2012-01-01

    The National Aeronautics and Space Administration Orion Flight Test Office was tasked with conducting a series of flight tests in several launch abort scenarios to certify that the Orion Launch Abort System is capable of delivering astronauts aboard the Orion Crew Module to a safe environment, away from a failed booster. The first of this series was the Orion Pad Abort 1 Flight-Test Vehicle, which was successfully flown on May 6, 2010 at the White Sands Missile Range in New Mexico. This report provides a brief overview of the three propulsive subsystems used on the Pad Abort 1 Flight-Test Vehicle. An overview of the propulsive systems originally planned for future flight-test vehicles is also provided, which also includes the cold gas Reaction Control System within the Crew Module, and the Peacekeeper first stage rocket motor encased within the Abort Test Booster aeroshell. Although the Constellation program has been cancelled and the operational role of the Orion spacecraft has significantly evolved, lessons learned from Pad Abort 1 and the other flight-test vehicles could certainly contribute to the vehicle architecture of many future human-rated space launch vehicles

  6. Studies of TNA and results of field tests of Kayenta`s advanced series compensation; Estudos do TNA e resultados dos testes de campo da compensacao serie avancada de Kayenta

    Energy Technology Data Exchange (ETDEWEB)

    Renz, W.; Weiss, S.; Capellin, R. [Siemens AG, Erlangen (Germany); Lemes, M.N. [Siemens S.A., XX (Brazil)

    1995-12-31

    This work presents the studies carried out in the TNA and the field tests performed. They confirmed the advanced series compensation behavior as predicted in the digital studies. Such studies included different ways of operating and controlling the installation, in other words, controlling the impedance, the current and the thyristor-switched reactor. Besides that, it has been studied fault cases and it has been corroborated a reduction in the nominal values of lightning arresters and in circuit breakers requests. Damping studies of sub-synchronous resonance have also been carried out and the conclusions are shown 4 refs., 9 figs.

  7. SAFE Newsletter

    OpenAIRE

    2013-01-01

    The Center of Excellence SAFE – “Sustainable Architecture for Finance in Europe” – is a cooperation of the Center for Financial Studies and Goethe University Frankfurt. It is funded by the LOEWE initiative of the State of Hessen (Landes-Offensive zur Entwicklung wissenschaftlich-ökonomischer Exzellenz). SAFE brings together more than 40 professors and just as many junior researchers who are all dedicated to conducting research in support of a sustainable financial architecture. The Center has...

  8. High heat flux tests of the WENDELSTEIN 7-X pre-series target elements - experimental evaluation of the thermo-mechanical behaviour

    International Nuclear Information System (INIS)

    Greuner, H.; Boeswirth, B.; Boscary, J.; Plankensteiner, A.; Schedler, B.

    2006-01-01

    The HHF testing of WENDELSTEIN 7-X pre-series target elements is an indispensable step in the qualification of the manufacturing process. The finally 890 divertor target elements are made of an actively water-cooled CuCrZr heat sink covered with flat tiles of CFC NB31 as plasma facing material. A set of 20 full scale pre-series elements was manufactured by PLANSEE to validate the materials and manufacturing technologies prior to the start of the series production. Due to the large mismatch in the coefficients of thermal expansion for CFC and CuCrZr - resulting in high residual stresses as well as high operation-induced stresses - the bonding zone between CFC and CuCrZr was detected to be the most critical issue for the operational behaviour of the target elements. To achieve a sufficiently high manufacturing quality together with a high lifetime during operation thermal testing of full scale mockups was performed in combination with extensive FEM analyses. In both cases heat loads were applied similar to the expected heat loads in W7-X. All pre-series elements were tested in the ion beam test facility GLADIS. The elements were tested with 100 cycles of 10 MW/m 2 and several elements with even higher cycle numbers and heat loads up to 24 MW/m 2 . The instrumentation of the targets (thermocouples, strain gages) and the infrared camera observation of the heat loaded surface allow an experimental evaluation of the thermo-mechanical behaviour of the tested elements. The main result is a good agreement between experimental data and numerically computed predictions. Hot spots were, however, observed at the edges of several tiles during the HHF tests indicating local bonding problems. Therefore, a programme of fully 3D nonlinear thermal-mechanical FEM calculations was started to evaluate the thermo-mechanical behavior of the target elements with special focus on the optimization of the stress situation in the bonding zone between the CFC and the CuCrZr heat sink. This

  9. Pesticide patch test series for the assessment of allergic contact dermatitis among banana plantation workers in panama.

    Science.gov (United States)

    Penagos, Homero; Ruepert, Clemens; Partanen, Timo; Wesseling, Catharina

    2004-09-01

    Irritant contact dermatitis and allergic contact dermatitis (ACD) are frequent among agricultural workers and require targeted interventions. Patch testing is necessary for differential diagnosis, but patch testing with pesticides is uncommon. This study explores the frequency of ACD and sensitization to pesticides among highly exposed banana plantation workers. Frequently and recently used pesticides on banana plantations in Divala, Panama, were documented. A pesticide patch test tray specific for this population was prepared. A structured interview was administered to 366 participants, followed by a complete skin examination. The pesticide patch test series, as well as a standard patch test series, was applied to 37 workers with dermatoses likely to be pesticide related and to 23 control workers without dermatoses. The pesticide patch tests identified 15 cases (41%) of ACD (20 positive reactions) among the 37 workers diagnosed with pesticide dermatosis. Three controls had allergic reactions to pesticides (4 positive reactions). The pesticides were carbaryl (5 cases), benomyl (4 cases), ethoprophos (3), chlorothalonil (2), imazalil (2), glyphosate (2), thiabendazole (2), chlorpyrifos (1), oxyfluorfen (1), propiconazole (1), and tridemorph (1). Ethoprophos and tridemorph had not been previously identified as sensitizers. Thus, the prevalence of ACD was 0.03 (15 of 366). On the basis of observed prevalences of positive patch-test reactions among the subgroups with and without dermatoses, we estimated that > or = 16% of the entire population may be sensitized to pesticides. Sensitization to pesticides among banana plantation workers is a frequent occupational health problem. Pesticide patch test trays should be used in assessing skin diseases in highly exposed workers.

  10. Approximate k-NN delta test minimization method using genetic algorithms: Application to time series

    CERN Document Server

    Mateo, F; Gadea, Rafael; Sovilj, Dusan

    2010-01-01

    In many real world problems, the existence of irrelevant input variables (features) hinders the predictive quality of the models used to estimate the output variables. In particular, time series prediction often involves building large regressors of artificial variables that can contain irrelevant or misleading information. Many techniques have arisen to confront the problem of accurate variable selection, including both local and global search strategies. This paper presents a method based on genetic algorithms that intends to find a global optimum set of input variables that minimize the Delta Test criterion. The execution speed has been enhanced by substituting the exact nearest neighbor computation by its approximate version. The problems of scaling and projection of variables have been addressed. The developed method works in conjunction with MATLAB's Genetic Algorithm and Direct Search Toolbox. The goodness of the proposed methodology has been evaluated on several popular time series examples, and also ...

  11. Vitamin D status, bone mineral density and mental health in young Australian women: the Safe-D study

    Directory of Open Access Journals (Sweden)

    Emma T. Callegari

    2015-11-01

    Full Text Available Background. Vitamin D deficiency has been associated with both poor bone health and mental ill-health. More recently, a number of studies have found individuals with depressive symptoms tend to have reduced bone mineral density. To explore the interrelationships between vitamin D status, bone mineral density and mental-ill health we are assessing a range of clinical, behavioural and lifestyle factors in young women (Part A of the Safe-D study. Design and methods. Part A of the Safe-D study is a cross-sectional study aiming to recruit 468 young females aged 16-25 years living in Victoria, Australia, through Facebook advertising. Participants are required to complete an extensive, online questionnaire, wear an ultra-violet dosimeter for 14 consecutive days and attend a study site visit. Outcome measures include areal bone mineral measures at the lumbar spine, total hip and whole body, as well as soft tissue composition using dual energy x-ray absorptiometry. Trabecular and cortical volumetric bone density at the tibia is measured using peripheral quantitative computed tomography. Other tests include serum 25-hydroxyvitamin D, serum biochemistry and a range of health markers. Details of mood disorder/s and depressive and anxiety symptoms are obtained by self-report. Cutaneous melanin density is measured by spectrophotometry. Expected impact. The findings of this cross-sectional study will have implications for health promotion in young women and for clinical care of those with vitamin D deficiency and/or mental ill-health. Optimising both vitamin D status and mental health may protect against poor bone health and fractures in later life.

  12. Operation and control strategies in pre-series testing of cold circulating pumps for ITER

    International Nuclear Information System (INIS)

    Bhattacharya, R.; Vaghela, H.; Sarkar, B.; Srinivas, M.; Choukekar, K.

    2013-01-01

    Cryo-distribution system of ITER is responsible for the distribution and control of forced-flow supercritical helium for cooling of the superconducting magnets and the cryo-pumps. The requirements of cold circulating pumps (CCP) for mass flow rates and performance are much higher than presently existing and commercially available one used at 4.0 K helium. Design up-scaling with pre-series test of CCP has been proposed including test infrastructure. Operation and control strategies for the test distribution box (TDB) of test infrastructure have been developed and analyzed using steady state and dynamic process simulation to cope with the functional requirements of CCPs. Off-normal scenario with CCP inlet pressure variation is an important concern, dynamic process responses during such scenario have been evaluated to verify the operability of CCP. The paper describes process simulation to cope with the functional requirements of CCPs along with evaluation of off-normal scenario to verify the operability of CCP. (author)

  13. Postirradiation examination results for the Irradiation Effects Test Series IE-ST-2, Rod IE-002

    International Nuclear Information System (INIS)

    Murdock, B.A.

    1977-12-01

    A postirradiation examination was conducted on a zircaloy-clad, UO 2 -fueled, pressurized water reactor (PWR) type rod which had been tested in the Power Burst Facility as part of the Irradiation Effects Test Series of the Thermal Fuels Behavior Program. The fuel rod, previously irradiated to a burnup of 15,800 MWd/t was subjected to a power ramp from 28 to 55 kW/m peak power at an average ramp rate of 4 kW/m/min. Posttest fuel restructuring and relocation, fission product redistribution, and fuel rod cladding deformation were evaluated and analyzed

  14. Safe Handling of Radioisotopes

    International Nuclear Information System (INIS)

    1958-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it has been considered an urgent task to provide users of radioisotopes with a manual of practice for the safe handling of these substances. Such a manual is presented here and represents the first of a series of manuals and codes to be issued by the Agency. It has been prepared after careful consideration of existing national and international codes of radiation safety, by a group of international experts and in consultation with other international bodies. At the same time it is recommended that the manual be taken into account as a basic reference document by Member States of the Agency in the preparation of national health and safety documents covering the use of radioisotopes.

  15. The safe use of radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    of Sealed Sources', and 'Safety and Regulation of Radiation Sources', were held at Argonne National Laboratory, Argonne, Illinois, in 1989 and 1990, respectively. Two regional courses on 'Safety and Regulation of Radiation Sources', were held in 1991, one in Mexico City, in Spanish, for the Latin American Region, and the other in Kuala Lumpur, Malaysia, for the Asian Region. In order to encourage training in radiation safety, the IAEA developed a new series on training courses, the first of which is the Manual on Safe Transport of Radioactive Material, issued in 1991. Because of the success of this manual and of the five training courses held in 1989, 1990 and 1991 on the safety of radiation sources, it was decided to develop a hotline on the safe useand regulation of radiation sources. This manual may also be used at other such courses that individual Member States may wish to sponsor.

  16. The safe use of radiation sources

    International Nuclear Information System (INIS)

    1995-01-01

    of Sealed Sources', and 'Safety and Regulation of Radiation Sources', were held at Argonne National Laboratory, Argonne, Illinois, in 1989 and 1990, respectively. Two regional courses on 'Safety and Regulation of Radiation Sources', were held in 1991, one in Mexico City, in Spanish, for the Latin American Region, and the other in Kuala Lumpur, Malaysia, for the Asian Region. In order to encourage training in radiation safety, the IAEA developed a new series on training courses, the first of which is the Manual on Safe Transport of Radioactive Material, issued in 1991. Because of the success of this manual and of the five training courses held in 1989, 1990 and 1991 on the safety of radiation sources, it was decided to develop a hotline on the safe use and regulation of radiation sources. This manual may also be used at other such courses that individual Member States may wish to sponsor

  17. Antidiabetic Activity Test of Ethanolic Seri Leave’s (Muntingia Calabura L.) Extract in Male Rats Induced by Alloxan

    OpenAIRE

    Herlina Herlina; Annisa Amriani; Indah Solihah; Rizky Sintya

    2018-01-01

    Antidiabetic activity test of ethanol extract of seri leave (Muntingia calabura L.) rats induced by alloxan has been done. Male wistar albino rats are used as animal models which divided into 6 groups, normal group (aquadest), negative control group (Na CMC 0,5%), positive control group (glibenclamide 0,43 mg/200 gBB), and 1, 2, and 3 treatment groups (ethanol extract of seri leave 65, 130, dan 260 mg/kgBB). Rats blood glucose level after induced intraperitoneally by alloxan 130 mg/kgBB can b...

  18. Safe Grid

    Science.gov (United States)

    Chow, Edward T.; Stewart, Helen; Korsmeyer, David (Technical Monitor)

    2003-01-01

    The biggest users of GRID technologies came from the science and technology communities. These consist of government, industry and academia (national and international). The NASA GRID is moving into a higher technology readiness level (TRL) today; and as a joint effort among these leaders within government, academia, and industry, the NASA GRID plans to extend availability to enable scientists and engineers across these geographical boundaries collaborate to solve important problems facing the world in the 21 st century. In order to enable NASA programs and missions to use IPG resources for program and mission design, the IPG capabilities needs to be accessible from inside the NASA center networks. However, because different NASA centers maintain different security domains, the GRID penetration across different firewalls is a concern for center security people. This is the reason why some IPG resources are been separated from the NASA center network. Also, because of the center network security and ITAR concerns, the NASA IPG resource owner may not have full control over who can access remotely from outside the NASA center. In order to obtain organizational approval for secured remote access, the IPG infrastructure needs to be adapted to work with the NASA business process. Improvements need to be made before the IPG can be used for NASA program and mission development. The Secured Advanced Federated Environment (SAFE) technology is designed to provide federated security across NASA center and NASA partner's security domains. Instead of one giant center firewall which can be difficult to modify for different GRID applications, the SAFE "micro security domain" provide large number of professionally managed "micro firewalls" that can allow NASA centers to accept remote IPG access without the worry of damaging other center resources. The SAFE policy-driven capability-based federated security mechanism can enable joint organizational and resource owner approved remote

  19. Safe and effective use of medicines for ethnic minorities

    DEFF Research Database (Denmark)

    Dam, Pernille; El-Souri, Mira Mahmoud; Herborg, Hanne

    2015-01-01

    , there was a need to adapt a previously developed and validated medicine-based intervention “safe and effective use of medicines” to this vulnerable group of unemployed ethnic minority patients. Methods: The objective of this before-after study was to improve medicines adherence, health status and work ability...... of the target group through an individualized pharmacist delivered intervention with focus on safe and effective implementation of medical treatments. The target group was ethnic minorities of non-western origin affiliated with a job center. Results: At baseline, 35.7 % of the patients had a potential adherence...... to the intervention. Conclusion: The counseling program “Safe and effective use of medicines” was successfully adapted to unemployed ethnic minority patients, and tested in a new collaboration between job centers and community pharmacies. The counseling program resulted in statistically significant improvements...

  20. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012

    DEFF Research Database (Denmark)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A

    2015-01-01

    BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data of patie......BACKGROUND: Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. OBJECTIVE: To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. METHODS: Data...... of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. RESULTS......: Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance...

  1. Illustration of the WPS benefit through BATMAN test series: Tests on large specimens under WPS loading configurations

    International Nuclear Information System (INIS)

    Yuritzinn, T.; Ferry, L.; Chapuliot, S.; Mongabure, P.; Moinereau, D.; Dahl, A.; Gilles, P.

    2008-01-01

    To study the effects of warm pre-stressing on the toughness of reactor pressure vessel steel, the 'Commissariat a l Energie Atomique', in collaboration with 'Electricite de France' and AREVA-NP, has made a study combining modeling and a series of experiments on large specimens submitted to a thermal shock or isothermal cooling. The tests were made on 18MND5 ferritic steel bars, containing a short or large fatigue pre-crack. The effect of 'warm pre-stressing' was confirmed, in the two cases of a fast thermal shock creating a gradient across the thickness of the bar and for gradual uniform cooling. In both cases, no propagation was observed during the thermal transient. Fracture occurred under low temperature conditions, at the end of the test when the tensile load was increased. The failure loads recorded were substantially higher than during pre-stressing. To illustrate the benefit of the WPS effect, numerical interpretations were performed using either global approach or local approach criteria. WPS effect and capability of models to predict it were then clearly shown. (authors)

  2. Unmanned Aircraft Systems Traffic Management (UTM) Safely Enabling UAS Operations in Low-Altitude Airspace

    Science.gov (United States)

    Kopardekar, Parimal H.

    2016-01-01

    in the airspace. In its most mature form, the UTM system could be developed using autonomicity characteristics that include self-configuration, self-optimization and self-protection. The self-configuration aspect could determine whether the operations should continue given the current andor predicted windweather conditions. NASA envisions concepts for two types of possible UTM systems. The first type would be a Portable UTM system, which would move from between geographical areas and support operations such as precision agriculture and disaster relief. The second type of system would be a Persistent UTM system, which would support low-altitude operations and provide continuous coverage for a geographical area. Either system would require persistent communication, navigation, and surveillance (CNS) coverage to track, ensure, and monitor conformance. What is NASA doing to test the technologies? NASA's near-term goal is the development and demonstration of a possible future UTM system that could safely enable low-altitude airspace and UAS operations. Working alongside many committed government, industry and academic partners, NASA is leading the research, development and testing that is taking place in a series of activities called Technology Capability Levels (TCL), each increasing in complexity. UTM TCL1 concluded field testing in August 2015 and is undergoing additional testing at an FAA site.

  3. Patch test reactions associated with sunscreen products and the importance of testing to an expanded series: retrospective analysis of North American Contact Dermatitis Group data, 2001 to 2010.

    Science.gov (United States)

    Warshaw, Erin M; Wang, Michael Z; Maibach, Howard I; Belsito, Donald V; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Sasseville, Denis; Zirwas, Matthew J; Fowler, Joseph F; DeKoven, Joel G; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J

    2013-01-01

    Both active and inactive ingredients in sunscreen may cause contact dermatitis. This study aimed to describe allergens associated with a sunscreen source. A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 2001 and 2010 was performed. Of 23,908 patients patch tested, 219 (0.9%) had sunscreen coded as an allergen source. Patients who were male, with occupational dermatitis, or older (older than 40 years) had significantly lower rates of allergic reactions to sunscreens; the most commonly affected areas were the face and exposed sites (P Contact Dermatitis Group screening series of 65 to 70 allergens. A supplemental antigen series is important in detecting allergy to sunscreens.

  4. A national evaluation of Safe Schools/Healthy Students: outcomes and influences.

    Science.gov (United States)

    Derzon, James H; Yu, Ping; Ellis, Bruce; Xiong, Sharon; Arroyo, Carmen; Mannix, Danyelle; Wells, Michael E; Hill, Gary; Rollison, Julia

    2012-05-01

    The Safe Schools/Healthy Students (SS/HS) Initiative has awarded over $2 billion in grants to more than 350 school districts in partnership with local mental health, law enforcement, and juvenile justice agencies. To estimate the impact of grantee characteristics, grant operations, and near-term outcomes in reducing violence and substance use, promoting mental health, and enhancing school safety, logged odds ratios (LORs) were calculated contrasting Year 3 with Baseline performance from grantee-provided data on seven outcome measures. After comparing grantee performance across outcomes and outcomes across grantees, the LORs were entered as dependent variables in a series of meta-regressions in which grantee characteristics, grant operations, and near-term outcomes were tested after controlling for pre-grant characteristics. Findings indicate that the SS/HS Initiative significantly improved most outcomes, that within-grantee performance varied greatly by outcome, and that random-effects meta-regression appreciably decreased the variance available for modeling. The approach demonstrates that the SS/HS Initiative is effective and that locally collected performance data can be used to estimate grantee success in improving youth outcomes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Piloted simulation tests of propulsion control as backup to loss of primary flight controls for a mid-size jet transport

    Science.gov (United States)

    Bull, John; Mah, Robert; Davis, Gloria; Conley, Joe; Hardy, Gordon; Gibson, Jim; Blake, Matthew; Bryant, Don; Williams, Diane

    1995-01-01

    Failures of aircraft primary flight-control systems to aircraft during flight have led to catastrophic accidents with subsequent loss of lives (e.g. , DC-1O crash, B-747 crash, C-5 crash, B-52 crash, and others). Dryden Flight Research Center (DFRC) investigated the use of engine thrust for emergency flight control of several airplanes, including the B-720, Lear 24, F-15, C-402, and B-747. A series of three piloted simulation tests have been conducted at Ames Research Center to investigate propulsion control for safely landing a medium size jet transport which has experienced a total primary flight-control failure. The first series of tests was completed in July 1992 and defined the best interface for the pilot commands to drive the engines. The second series of tests was completed in August 1994 and investigated propulsion controlled aircraft (PCA) display requirements and various command modes. The third series of tests was completed in May 1995 and investigated PCA full-flight envelope capabilities. This report describes the concept of a PCA, discusses pilot controls, displays, and procedures; and presents the results of piloted simulation evaluations of the concept by a cross-section of air transport pilots.

  6. The Conceptual Design of Innovative Safe PWR

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han-Gon [Centural Research Institute, Daejeon (Korea, Republic of); Heo, Sun [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2016-10-15

    Most of countries operating NPPs have been performed post-Fukushima improvements as short-term countermeasure to enhance the safety of operating NPPs. Separately, vendors have made efforts on developing passive safety systems as long-term and ultimate countermeasures. AP1000 designed by Westinghouse Electric Company has passive safety systems including the passive emergency core cooling system (PECCS), the passive residual heat removal system (PRHRS), and the passive containment cooling system (PCCS). ESBWR designed by GE-Hitachi also has passive safety systems consisting of the isolation condenser system, the gravity driven cooling system and the PCCS. Other countries including China and Russia have made efforts on developing passive safety systems for enhancing the safety of their plants. In this paper, we summarize the design goals and main design feature of innovative safe PWR, iPOWER which is standing for Innovative Passive Optimized World-wide Economical Reactor, and show the developing status and results of research projects. To mitigate an accident without electric power and enhance the safety level of PWR, the conceptual designs of passive safety system and innovative safe PWR have been performed. It includes the PECCS for core cooling and the PCCS for containment cooling. Now we are performing the small scale and separate effect tests for the PECCS and the PCCS and preparing the integral effect test for the PECCS and real scale test for the PCCS.

  7. Guidelines for safe design of shipping packages against brittle fracture

    International Nuclear Information System (INIS)

    1993-08-01

    In 1992, the ninth meeting of the Standing Advisory Group on the Safe Transport of Radioactive Materials recommended the publication of this TECDOC in an effort to promote the widest debate on the criteria for the brittle fracture safe design of transport packages. The published IAEA advice on the influence of brittle fracture on material integrity is contained in Appendix IX of the Advisory Material for the IAEA Regulations for the Safety Transport of Radioactive Material (1985 Edition, as amended 1990), Safety Series No. 37. This guidance is limited in scope, dealing only with ferritic steels in general terms. It is becoming more common for designers to specify materials other than austenitic stainless steel for packaging components. The data on ferritic steels cannot be assumed to apply to other metals, hence the need for further guidance on the development of relationships describing material properties at low temperatures. The methods described in this TECDOC will be considered by the Revision Panel for inclusion in the 1996 Edition of the IAEA Regulations for the Safe Transport of Radioactive Material and the supporting documents. If accepted by the Revision Panel, this advice will be a candidate for upgrading to a Safety Practice. In the interim period, this TECDOC offers provisional advice on brittle fracture evaluation. It is acknowledged that, at this stage, the views expressed do not necessarily reflect those of the governments of Member States or organizations under whose auspices this manuscript was produced. Refs and figs

  8. Automatic Management Systems for the Operation of the Cryogenic Test Facilities for LHC Series Superconducting Magnets

    CERN Document Server

    Tovar-Gonzalez, A; Herblin, L; Lamboy, J P; Vullierme, B

    2006-01-01

    Prior to their final preparation before installation in the tunnel, the ~1800 series superconducting magnets of the LHC machine shall be entirely tested at reception on modular test facilities. The operation 24 hours per day of the cryogenic test facilities is conducted in turn by 3-operator teams, assisted in real time by the use of the Test Bench Priorities Handling System, a process control application enforcing the optimum use of cryogenic utilities and of the "Tasks Tracking System", a web-based e-traveller application handling 12 parallel 38-task test sequences. This paper describes how such computer-based management systems can be used to optimize operation of concurrent test benches within technical boundary conditions given by the cryogenic capacity, and how they can be used to study the efficiency of the automatic steering of all individual cryogenic sub-systems. Finally, this paper presents the overall performance of the cryomagnet test station for the first complete year of operation at high produ...

  9. Advisory Material for the IAEA Regulations for the Safe Transport of Radioactive Material. Safety Guide (Spanish Edition)

    International Nuclear Information System (INIS)

    2010-01-01

    This Safety Guide provides recommendations on achieving and demonstrating compliance with IAEA Safety Standards Series No. TS-R-1, Regulations for the Safe Transport of Radioactive Material, 2005 Edition, establishing safety requirements to be applied to the national and international transport of radioactive material. Transport is deemed to comprise all operations and conditions associated with and involved in the movement of radioactive material; these include the design, fabrication and maintenance of packaging, and the preparation, consigning, handling, carriage, storage in transit and receipt at the final destination of packages. This publication supersedes IAEA Safety Series No. TS-G-1.1, 2002 Edition

  10. Irradiation Effects Test Series: Test IE-3. Test results report

    International Nuclear Information System (INIS)

    Farrar, L.C.; Allison, C.M.; Croucher, D.W.; Ploger, S.A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m 2 . After a flow reduction to 2120 kg/s-m 2 , film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions

  11. Clinical Decision Support and Optional Point of Care Testing of Renal Function for Safe Use of Antibiotics in Elderly Patients : A Retrospective Study in Community Pharmacy Practice

    NARCIS (Netherlands)

    Heringa, Mette; Floor-Schreudering, Annemieke; De Smet, Peter A G M; Bouvy, Marcel L

    2017-01-01

    OBJECTIVE: The aim was to investigate the management of drug therapy alerts on safe use of antibiotics in elderly patients with (potential) renal impairment and the contribution of optional creatinine point of care testing (PoCT) in community pharmacy practice. METHODS: Community pharmacists used a

  12. Integrated Test and Evaluation (ITE) Flight Test Series 4

    Science.gov (United States)

    Marston, Michael

    2016-01-01

    The integrated Flight Test 4 (FT4) will gather data for the UAS researchers Sense and Avoid systems (referred to as Detect and Avoid in the RTCA SC 228 ToR) algorithms and pilot displays for candidate UAS systems in a relevant environment. The technical goals of FT4 are to: 1) perform end-to-end traffic encounter test of pilot guidance generated by DAA algorithms; 2) collect data to inform the initial Minimum Operational Performance Standards (MOPS) for Detect and Avoid systems. FT4 objectives and test infrastructure builds from previous UAS project simulations and flight tests. NASA Ames (ARC), NASA Armstrong (AFRC), and NASA Langley (LaRC) Research Centers will share responsibility for conducting the tests, each providing a test lab and critical functionality. UAS-NAS project support and participation on the 2014 flight test of ACAS Xu and DAA Self Separation (SS) significantly contributed to building up infrastructure and procedures for FT3 as well. The DAA Scripted flight test (FT4) will be conducted out of NASA Armstrong over an eight-week period beginning in April 2016.

  13. C-SAFE: A Computer-Delivered Sexual Health Promotion Program for Latinas.

    Science.gov (United States)

    Klein, Charles H; Kuhn, Tamara; Altamirano, Midori; Lomonaco, Carmela

    2017-07-01

    This article describes the development and evaluation of C-SAFE (Sexual Awareness for Everyone), a computer-delivered sexual health promotion program for Latinas. We first describe the process of adapting an evidence-based, group-level intervention into an individually administered computer-delivered program. We then present the methods and results of a randomized control trial with 321 Latinas in California and Florida to test C-SAFE's preliminary efficacy in reducing sexual health risk. We found no statistically significant differences between the two conditions at a six-month follow-up in terms of sexual behaviors or attitudes toward sexually transmitted infections and condoms, although C-SAFE women reported fewer days in the past month when their mental health was not good (p = .02). C-SAFE condition women also reported more satisfaction than control condition women in their assessment of information presentation (on a scale of 1 = poor and 5 = excellent; C-SAFE = 4.45 vs. control = 4.25, p = .053) and having learned something new (C-SAFE = 95.1% vs. control = 79.3%, χ 2 importance of teachable moments, matching of delivery modalities to implementation contexts, and possible directions for evidence-based sexual health promotion programs given the current sexual health landscape.

  14. Are Detox Diets Safe?

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Are Detox Diets Safe? KidsHealth / For Teens / Are Detox Diets ... seguras las dietas de desintoxicación? What Is a Detox Diet? The name sounds reassuring — everyone knows that ...

  15. Helicopter Flight Test of 3-D Imaging Flash LIDAR Technology for Safe, Autonomous, and Precise Planetary Landing

    Science.gov (United States)

    Roback, Vincent; Bulyshev, Alexander; Amzajerdian, Farzin; Reisse, Robert

    2013-01-01

    Two flash lidars, integrated from a number of cutting-edge components from industry and NASA, are lab characterized and flight tested for determination of maximum operational range under the Autonomous Landing and Hazard Avoidance Technology (ALHAT) project (in its fourth development and field test cycle) which is seeking to develop a guidance, navigation, and control (GN&C) and sensing system based on lidar technology capable of enabling safe, precise crewed or robotic landings in challenging terrain on planetary bodies under any ambient lighting conditions. The flash lidars incorporate pioneering 3-D imaging cameras based on Indium-Gallium-Arsenide Avalanche Photo Diode (InGaAs APD) and novel micro-electronic technology for a 128 x 128 pixel array operating at 30 Hz, high pulse-energy 1.06 micrometer Nd:YAG lasers, and high performance transmitter and receiver fixed and zoom optics. The two flash lidars are characterized on the NASA-Langley Research Center (LaRC) Sensor Test Range, integrated with other portions of the ALHAT GN&C system from partner organizations into an instrument pod at NASA-JPL, integrated onto an Erickson Aircrane Helicopter at NASA-Dryden, and flight tested at the Edwards AFB Rogers dry lakebed over a field of human-made geometric hazards during the summer of 2010. Results show that the maximum operational range goal of 1 km is met and exceeded up to a value of 1.2 km. In addition, calibrated 3-D images of several hazards are acquired in real-time for later reconstruction into Digital Elevation Maps (DEM's).

  16. Safe transport of radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-12-31

    The film shows the widespread use of radioactive materials in industry, medicine and research and explains the need for transporting nuclear material from producer to user. It shows the way in which packages containing radioactive materials are handled during transport and explains the most important provisions of the IAEA transport regulations, safety series no. 6, such as packaging design criteria and testing requirements, illustrated by various tests carried out, specimen packages and package and freight container labelling. Also illustrated are practical measures to be taken in case of an accident

  17. Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet

    Science.gov (United States)

    Baker, Paul; Repaci, Max; Sames, David

    1998-01-01

    Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.

  18. Short-circuit testing of monofilar Bi-2212 coils connected in series and in parallel

    International Nuclear Information System (INIS)

    Polasek, A; Dias, R; Serra, E T; Filho, O O; Niedu, D

    2010-01-01

    Superconducting Fault Current Limiters (SCFCL's) are one of the most promising technologies for fault current limitation. In the present work, resistive SCFCL components based on Bi-2212 monofilar coils are subjected to short-circuit testing. These SCFCL components can be easily connected in series and/or in parallel by using joints and clamps. This allows a considerable flexibility to developing larger SCFCL devices, since the configuration and size of the whole device can be easily adapted to the operational conditions. The single components presented critical current (Ic) values of 240-260 A, at 77 K. Short-circuits during 40-120 ms were applied. A single component can withstand a voltage drop of 126-252 V (0.3-0.6 V/cm). Components connected in series withstand higher voltage levels, whereas parallel connection allows higher rated currents during normal operation, but the limited current is also higher. Prospective currents as high as 10-40 kA (peak value) were limited to 3-9 kA (peak value) in the first half cycle.

  19. Safe Anesthesia For Every Tot

    DEFF Research Database (Denmark)

    Weiss, Markus; Vutskits, Laszlo; Hansen, Tom G

    2015-01-01

    PURPOSE OF REVIEW: The term 'safe use of anesthesia in children is ill-defined and requires definition of and focus on the 'safe conduct of pediatric anesthesia'. RECENT FINDINGS: The Safe Anesthesia For Every Tot initiative (www.safetots.org) has been set up during the last year to focus...... on the safe conduct of pediatric anesthesia. This initiative aims to provide guidance on markers of quality anesthesia care. The introduction and implementation of national regulations of 'who, where, when and how' are required and will result in an improved perioperative outcome in vulnerable children....... The improvement of teaching, training, education and supervision of the safe conduct of pediatric anesthesia are the main goals of the safetots.org initiative. SUMMARY: This initiative addresses the well known perioperative risks in young children, perioperative causes for cerebral morbidity as well as gaps...

  20. Thermal-hydraulic analysis of the semiscale Mod-1 blowdown heat transfer test series

    International Nuclear Information System (INIS)

    Cozzuol, J.M.

    1976-06-01

    Selected experimental thermal-hydraulic data from the recent Semiscale Mod-1 blowdown heat transfer test series are analyzed from an experimental viewpoint with emphasis on explaining those phenomena which influence core fluid behavior. Comparisons are made between the trends measured by the system instrumentation and the trends predicted by the RELAP4 computer code to aid in obtaining an understanding of the interactions between phenomena occurring in different parts of the system. The analyses presented in this report are valuable for evaluating the adequacy and improving the predictive capability of analytical models developed to predict the system response of a pressurized water reactor during a postulated loss-of-coolant accident

  1. Irradiation effects test series, test IE-5. Test results report

    International Nuclear Information System (INIS)

    Croucher, D.W.; Yackle, T.R.; Allison, C.M.; Ploger, S.A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m 2 for each rod. After a flow reduction to 1800 kg/s-m 2 , film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m 2 produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results

  2. Results of the first nuclear blowdown test on single fuel rods (LOC-11 Series in PBF)

    International Nuclear Information System (INIS)

    Larson, J.R.; Evans, D.R.; McCardell, R.K.

    1978-01-01

    This paper presents results of the first nuclear blowdown tests (LOC-11A, LOC-11B, LOC-11C) ever conducted. The Loss-of-Coolant Accident (LOCA) Test Series is being conducted in the Power Burst Facility (PBF) reactor at the Idaho National Engineering Laboratory, near Idaho Falls, Idaho, for the Nuclear Regulatory Commission. The objective of the LOC-11 tests was to obtain data on the behavior of pressurized and unpressurized rods when exposed to a blowdown similar to that expected in a pressurized water reactor (PWR) during a hypothesized double-ended cold-leg break. The data are being used for the development and verification of analytical models that are used to predict coolant and fuel rod pressure during a LOCA in a PWR

  3. Standard test method for determining the susceptibility to intergranular corrosion of 5XXX series Aluminum alloys by mass loss after exposure to nitric acid (NAMLT Test)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This test method describes a procedure for constant immersion intergranular corrosion testing of 5XXX series aluminum alloys. 1.2 This test method is applicable only to wrought products. 1.3 This test method covers type of specimen, specimen preparation, test environment, and method of exposure. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  4. Supporting safe driving with arthritis: developing a driving toolkit for clinical practice and consumer use.

    Science.gov (United States)

    Vrkljan, Brenda H; Cranney, Ann; Worswick, Julia; O'Donnell, Siobhan; Li, Linda C; Gélinas, Isabelle; Byszewski, Anna; Man-Son-Hing, Malcolm; Marshall, Shawn

    2010-01-01

    We conducted a series of focus groups to explore the information needs of clinicians and consumers related to arthritis and driving. An open coding analysis identified common themes across both consumer and clinician-based focus groups that underscored the importance of addressing driving-related concerns and the challenges associated with assessing safety. The results revealed that although driving is critical for maintaining independence and community mobility, drivers with arthritis experience several problems that can affect safe operation of a motor vehicle. Findings from this study are part of a broader research initiative that will inform the development of the Arthritis and Driving toolkit. This toolkit outlines strategies to support safe mobility for people with arthritis and will be an important resource in the coming years given the aging population.

  5. The safe home project.

    Science.gov (United States)

    Arphorn, Sara; Jiraniratisai, Sopaphan; Rungtakul, Rungsri; Phutta, Nikom

    2011-12-01

    The Thai Health Promotion Foundation supported the Improvement of Quality of Life of Informal Workers project in Ban Luang District, Amphur Photaram, Ratchaburi Province. There were many informal workers in Ban Luang District. Sweet-crispy fish producers in Ban Luang were the largest group among the sweet-crispy fish producers in Thailand. This project was aimed at improving living and working conditions of informal workers, with a focus on the sweet-crispy fish group. Good practices of improved living and working conditions were used to help informal workers build safe, healthy and productive work environments. These informal workers often worked in substandard conditions and were exposed to various hazards in the working area. These hazards included risk of exposure to hot work environment, ergonomics-related injuries, chemical hazards, electrical hazards etc. Ergonomics problems were commonly in the sweet-crispy fish group. Unnatural postures such as prolonged sitting were performed dominantly. One hundred and fifty informal workers participated in this project. Occupational health volunteers were selected to encourage occupational health and safety in four groups of informal workers in 2009. The occupational health volunteers trained in 2008 were farmers, beauty salon workers and doll makers. The occupational health and safety knowledge is extended to a new informal worker group: sweet-crispy fish producer, in 2009. The occupational health and safety training for sweet-crispy fish group is conducted by occupational health volunteers. The occupational health volunteers increased their skills and knowledge assist in to make safe home and safe community through participatory oriented training. The improvement of living and working condition is conducted by using a modified WISH, Work Improvement for Safe Home, checklist. The plans of improvement were recorded. The informal workers showed improvement mostly on material handling and storage. The safe uses and safe

  6. Non-parametric characterization of long-term rainfall time series

    Science.gov (United States)

    Tiwari, Harinarayan; Pandey, Brij Kishor

    2018-03-01

    The statistical study of rainfall time series is one of the approaches for efficient hydrological system design. Identifying, and characterizing long-term rainfall time series could aid in improving hydrological systems forecasting. In the present study, eventual statistics was applied for the long-term (1851-2006) rainfall time series under seven meteorological regions of India. Linear trend analysis was carried out using Mann-Kendall test for the observed rainfall series. The observed trend using the above-mentioned approach has been ascertained using the innovative trend analysis method. Innovative trend analysis has been found to be a strong tool to detect the general trend of rainfall time series. Sequential Mann-Kendall test has also been carried out to examine nonlinear trends of the series. The partial sum of cumulative deviation test is also found to be suitable to detect the nonlinear trend. Innovative trend analysis, sequential Mann-Kendall test and partial cumulative deviation test have potential to detect the general as well as nonlinear trend for the rainfall time series. Annual rainfall analysis suggests that the maximum changes in mean rainfall is 11.53% for West Peninsular India, whereas the maximum fall in mean rainfall is 7.8% for the North Mountainous Indian region. The innovative trend analysis method is also capable of finding the number of change point available in the time series. Additionally, we have performed von Neumann ratio test and cumulative deviation test to estimate the departure from homogeneity. Singular spectrum analysis has been applied in this study to evaluate the order of departure from homogeneity in the rainfall time series. Monsoon season (JS) of North Mountainous India and West Peninsular India zones has higher departure from homogeneity and singular spectrum analysis shows the results to be in coherence with the same.

  7. Safe Handling of Radioisotopes. First Edition with Revised Appendix I

    International Nuclear Information System (INIS)

    1966-01-01

    Under its Statute the International Atomic Energy Agency is empowered to provide for the application of standards of safety for protection against radiation to its own operations and to operations making use of assistance provided by it or with which it is otherwise directly associated. To this end authorities receiving such assistance are required to observe relevant health and safety measures prescribed by the Agency. As a first step, it was considered an urgent task to provide users of radioisotopes with a manual of practice for the safe handling of these substances. The first edition of such a manual was published in 1958 and represented the first of the 'Safety Series', a series of manuals and codes on health and safety published by the Agency. It was prepared after careful consideration of existing national and international codes of radiation safety by a group of international experts and in consultation with other international bodies. This edition presents the first revision. It incorporates in the Appendices the latest recommendations of the International Commission on Radiological Protection and extracts from the report of the Committee II of the I.C.R.P. on permissible dose for internal radiation. The Health Physics and Medical Addenda to this Manual, published as No. 2 and No. 3 in the Safety Series in 1960, give more complete advice to the user on specialized topics.

  8. Validity and reliability of a self-administered foot evaluation questionnaire (SAFE-Q).

    Science.gov (United States)

    Niki, Hisateru; Tatsunami, Shinobu; Haraguchi, Naoki; Aoki, Takafumi; Okuda, Ryuzo; Suda, Yasunori; Takao, Masato; Tanaka, Yasuhito

    2013-03-01

    The Japanese Society for Surgery of the Foot (JSSF) is developing a QOL questionnaire instrument for use in pathological conditions related to the foot and ankle. The main body of the outcome instrument (the Self-Administered Foot Evaluation Questionnaire, SAFE-Q version 2) consists of 34 questionnaire items, which provide five subscale scores (1: Pain and Pain-Related; 2: Physical Functioning and Daily Living; 3: Social Functioning; 4: Shoe-Related; and 5: General Health and Well-Being). In addition, the instrument has nine optional questionnaire items that provide a Sports Activity subscale score. The purpose of this study was to evaluate the test-retest reliability of the SAFE-Q. Version 2 of the SAFE-Q was administered to 876 patients and 491 non-patients, and the test-retest reliability was evaluated for 131 patients. In addition, the SF-36 questionnaire and the JSSF Scale scoring form were administered to all of the participants. Subscale scores were scaled such that the final sum of scores ranged between zero (least healthy) to 100 (healthiest). The intraclass correlation coefficients were larger than 0.7 for all of the scores. The means of the five subscale scores were between 60 and 75. The five subscales easily separated patients from non-patients. The coefficients for the correlations of the subscale scores with the scores on the JSSF Scale and the SF-36 subscales were all highly statistically significantly greater than zero (p valid and reliable. In the future, it will be beneficial to test the responsiveness of the SAFE-Q.

  9. Smart aircraft fastener evaluation (SAFE) system: a condition-based corrosion detection system for aging aircraft

    Science.gov (United States)

    Schoess, Jeffrey N.; Seifert, Greg; Paul, Clare A.

    1996-05-01

    The smart aircraft fastener evaluation (SAFE) system is an advanced structural health monitoring effort to detect and characterize corrosion in hidden and inaccessible locations of aircraft structures. Hidden corrosion is the number one logistics problem for the U.S. Air Force, with an estimated maintenance cost of $700M per year in 1990 dollars. The SAFE system incorporates a solid-state electrochemical microsensor and smart sensor electronics in the body of a Hi-Lok aircraft fastener to process and autonomously report corrosion status to aircraft maintenance personnel. The long-term payoff for using SAFE technology will be in predictive maintenance for aging aircraft and rotorcraft systems, fugitive emissions applications such as control valves, chemical pipeline vessels, and industrial boilers. Predictive maintenance capability, service, and repair will replace the current practice of scheduled maintenance to substantially reduce operational costs. A summary of the SAFE concept, laboratory test results, and future field test plans is presented.

  10. Safe cycling!

    CERN Multimedia

    Anaïs Schaeffer

    2012-01-01

    The HSE Unit will be running a cycling safety campaign at the entrances to CERN's restaurants on 14, 15 and 16 May. Pop along to see if they can persuade you to get back in the saddle!   With summer on its way, you might feel like getting your bike out of winter storage. Well, the HSE Unit has come up with some original ideas to remind you of some of the most basic safety rules. This year, the prevention campaign will be focussing on three themes: "Cyclists and their equipment", "The bicycle on the road", and "Other road users". This is an opportunity to think about the condition of your bike as well as how you ride it. From 14 to 16 May, representatives of the Swiss Office of Accident Prevention and the Touring Club Suisse will join members of the HSE Unit at the entrances to CERN's restaurants to give you advice on safe cycling (see box). They will also be organising three activity stands where you can test your knowle...

  11. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    Science.gov (United States)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Study of Railway Track Irregularity Standard Deviation Time Series Based on Data Mining and Linear Model

    Directory of Open Access Journals (Sweden)

    Jia Chaolong

    2013-01-01

    Full Text Available Good track geometry state ensures the safe operation of the railway passenger service and freight service. Railway transportation plays an important role in the Chinese economic and social development. This paper studies track irregularity standard deviation time series data and focuses on the characteristics and trend changes of track state by applying clustering analysis. Linear recursive model and linear-ARMA model based on wavelet decomposition reconstruction are proposed, and all they offer supports for the safe management of railway transportation.

  13. Residential tornado safe room from commodity wood products – impact and wind pressure testing

    Science.gov (United States)

    Robert H. Falk; James J. Bridwell; C. Adam Senalik; Marshall Begel

    2018-01-01

    A tornado safe room is a shelter designed to provide protection during a tornado and is specifically engineered to resist the high wind pressures and debris impact generated by these high wind events. The required performance criteria of these shelters has been established and is found in the International Code Council Standard for the Design and Construction of Storm...

  14. Visualization of and Software for Omnibus Test Based Change Detected in a Time Series of Polarimetric SAR Data

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Conradsen, Knut; Skriver, Henning

    2017-01-01

    Based on an omnibus likelihood ratio test statistic for the equality of several variance-covariance matrices following the complex Wishart distribution and a factorization of this test statistic with associated p-values, change analysis in a time series of multilook polarimetric SAR data...... in the covariance matrix representation is carried out. The omnibus test statistic and its factorization detect if and when change occurs. Using airborne EMISAR and spaceborne RADARSAT-2 data this paper focuses on change detection based on the p-values, on visualization of change at pixel as well as segment level......, and on computer software....

  15. Gas Generation from K East Basin Sludges and Irradiated Metallic Uranium Fuel Particles Series III Testing

    International Nuclear Information System (INIS)

    Schmidt, Andrew J.; Delegard, Calvin H.; Bryan, Samuel A.; Elmore, Monte R.; Sell, Rachel L.; Silvers, Kurt L.; Gano, Susan R.; Thornton, Brenda M.

    2003-01-01

    The path forward for managing of Hanford K Basin sludge calls for it to be packaged, shipped, and stored at T Plant until final processing at a future date. An important consideration for the design and cost of retrieval, transportation, and storage systems is the potential for heat and gas generation through oxidation reactions between uranium metal and water. This report, the third in a series (Series III), describes work performed at the Pacific Northwest National Laboratory (PNNL) to assess corrosion and gas generation from irradiated metallic uranium particles (fuel particles) with and without K Basin sludge addition. The testing described in this report consisted of 12 tests. In 10 of the tests, 4.3 to 26.4 g of fuel particles of selected size distribution were placed into 60- or 800-ml reaction vessels with 0 to 100 g settled sludge. In another test, a single 3.72-g fuel fragment (i.e., 7150-mm particle) was placed in a 60 ml reaction vessel with no added sludge. The twelfth test contained only sludge. The fuel particles were prepared by crushing archived coupons (samples) from an irradiated metallic uranium fuel element. After loading the sludge materials (whether fuel particles, mixtures of fuel particles and sludge, or sludge-only) into reaction vessels, the solids were covered with an excess of K Basin water, the vessels closed and connected to a gas measurement manifold, and the vessels back-flushed with inert neon cover gas. The vessels were then heated to a constant temperature. The gas pressures and temperatures were monitored continuously from the times the vessels were purged. Gas samples were collected at various times during the tests, and the samples analyzed by mass spectrometry. Data on the reaction rates of uranium metal fuel particles with water as a function of temperature and particle size were generated. The data were compared with published studies on metallic uranium corrosion kinetics. The effects of an intimate overlying sludge layer

  16. SAFE/SNAP application to shipboard security

    International Nuclear Information System (INIS)

    Grady, L.M.; Walker, J.L.; Polito, J.

    1981-11-01

    An application of the combined Safeguards Automated Facility Evaluation/Safeguards Network Analysis Procedure (SAFE/SNAP) modeling technique to a physical protection system (PPS) aboard a generic ship is described. This application was performed as an example of how the SAFE and SNAP techniques could be used. Estimates of probability of interruption and neutralization for the example shipboard PPS are provided by SAFE as well as an adversary scenario, which serves as input to SNAP. This adversary scenario is analyzed by SNAP through four cases which incorporate increasingly detailed security force tactics. Comparisons between the results of the SAFE and SNAP analyses are made and conclusions drawn on the validity of each technique. Feedback from SNAP to SAFE is described, and recommendations for upgrading the ship based on the results of the SAFE/SNAP application are also discussed

  17. Testing Commodities as Safe Haven and Hedging Instrument on ASEAN's Five Stock Markets

    OpenAIRE

    Robiyanto, Robiyanto

    2017-01-01

    This study attempts to analyze commodity market instruments such as gold, silver, platinum, palladium, and West Texas Intermediate (WTI) crude oil’s potential as hedge and safe haven toward some stock markets in South East Asia such as in Indonesia, Singapore, Malaysia, Philippines, and Thailand. To analyze the data, GARCH (1,1) was applied. The research findings showed that gold, silver, platinum, palladium, and WTI could not play their role as hedging instrument for five South East Asi...

  18. Changes in the regulations for the safe transport of radioactive material

    International Nuclear Information System (INIS)

    Lopez Vietri, Jorge R.; Vidal, Dora N.; Piumetti, Elsa H.; Capadona, Nancy M.

    2000-01-01

    The objective of this paper is to describe and to analyze the relevant changes, dealing with the design, operation and administrative requirements, to be introduced in the Revision 1 of the AR 10.16.1 standard 'Transport of radioactive material' that will be put into force on July, 1st 2001 by the Nuclear Regulatory Authority (competent authority of Argentina). In that way, the Revision 1 of the mentioned standard will be coincident with the 1996 edition (revised) of the 'Regulations for the safe transport of radioactive material', Safety Standards Series No. TS-R-1 (ST-1, revised) issued by the International Atomic Energy Agency (IAEA). (author)

  19. Safe Handling of Radioisotopes. Medical Addendum

    International Nuclear Information System (INIS)

    Hercik, F.; Jammet, H.

    1960-01-01

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains information necessary to medical officers concerned with the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the medical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  20. Chernobyl new safe confinement

    International Nuclear Information System (INIS)

    Dodd, L.

    2011-01-01

    The author presents the new safe confinement that will be commissioned at Unit 4 of the Chernobyl NPP in 2015. The confinement will ensure that Chernobyl Unit 4 will be placed in an environmentally safe condition for at least next 100 years. The article highlights the current work status, future perspectives and the feasibility of confinement concept [ru

  1. Asymptotically Safe Dark Matter

    DEFF Research Database (Denmark)

    Sannino, Francesco; Shoemaker, Ian M.

    2015-01-01

    We introduce a new paradigm for dark matter (DM) interactions in which the interaction strength is asymptotically safe. In models of this type, the coupling strength is small at low energies but increases at higher energies, and asymptotically approaches a finite constant value. The resulting...... searches are the primary ways to constrain or discover asymptotically safe dark matter....

  2. Household's willingness to pay for arsenic safe drinking water in Bangladesh.

    Science.gov (United States)

    Khan, Nasreen Islam; Brouwer, Roy; Yang, Hong

    2014-10-01

    This study examines willingness to pay (WTP) in Bangladesh for arsenic (As) safe drinking water across different As-risk zones, applying a double bound discrete choice value elicitation approach. The study aims to provide a robust estimate of the benefits of As safe drinking water supply, which is compared to the results from a similar study published almost 10 years ago using a single bound estimation procedure. Tests show that the double bound valuation design does not suffer from anchoring or incentive incompatibility effects. Health risk awareness levels are high and households are willing to pay on average about 5 percent of their disposable average annual household income for As safe drinking water. Important factors influencing WTP include the bid amount to construct communal deep tubewell for As safe water supply, the risk zone where respondents live, household income, water consumption, awareness of water source contamination, whether household members are affected by As contamination, and whether they already take mitigation measures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. SAFE Journal. Volume 35, Number 1, Spring 2007

    Science.gov (United States)

    2007-01-01

    Division Eye Tactical, Inc. - Sales and Marketing Division First Technology Safety Systems, Inc. Fujikura Parachute Co., Ltd. FXC Corporation... markets for environmentally friendly products. The E.PA is considering using Section 6 of the Toxic Substances Control Act (TSCA) to regulate...CH,OH 0,N SAFE Journal - Vol 35(1) - Spring 2007 15 RESEARC H, DEVELOPMENT. TEST & EVALUATION SECTION Figure 2. Preparation of KDNP (1) using a

  4. Fabrication and mechanical test data for the four 6-inch-thick intermediate test vessels made from steel plate for the Heavy Section Steel Program

    International Nuclear Information System (INIS)

    Childress, C.E.

    1976-01-01

    The HSST Program has among its goals the objective of demonstrating the capability to predict safe behavior of thick-walled pressure vessels containing flaws of known dimensions under frangible, transitional, and tough loading regimes. To accomplish these objectives the program is conducting a series of tests involving 6-in.-thick pressure vessels which will serve as test specimens for assisting in the characterization of failure under these loading conditions. Among the vessels a number of parameters, such as weld type, weld location, flaw size and shape, and test temperature and pressure, will be selectively varied to show that a rationale exists for dealing with the varied stress and metallurgical states which normally exist in commercial nuclear reactor vessels. Each vessel will serve as a go, no-go determination of critical flaw size for a specific set of test parameters. Item 4 of the previous issues in this series covers the fabrication details of the first six 6-in.-thick test vessels, which were fabricated from ASTM A-508 Cl 2 forging materials. This report covers the fabrication details of four additional 6-in.-thick intermediate test vessels having shell courses fabricated from ASTM A-533 Gr B Cl 1 plate. The remaining components were made from forgings. Essentially this report is a continuation of ORNL-TM-4351; it describes the manufacturing details of the individual parts and their ultimate assembly into finished vessels. Details concerning chemical composition and mechanical and nondestructive test data are presented

  5. Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines.

    Science.gov (United States)

    Swetapadma, Aleena; Yadav, Anamika

    2015-01-01

    Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance.

  6. Irradiation Effects Test Series: Test IE-3. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, L. C.; Allison, C. M.; Croucher, D. W.; Ploger, S. A.

    1977-10-01

    The objectives of the test reported were to: (a) determine the behavior of irradiated fuel rods subjected to a rapid power increase during which the possibility of a pellet-cladding mechanical interaction failure is enhanced and (b) determine the behavior of these fuel rods during film boiling following this rapid power increase. Test IE-3 used four 0.97-m long pressurized water reactor type fuel rods fabricated from previously irradiated fuel. The fuel rods were subjected to a preconditioning period, followed by a power ramp to 69 kW/m at a coolant mass flux of 4920 kg/s-m/sup 2/. After a flow reduction to 2120 kg/s-m/sup 2/, film boiling occurred on the fuel rods. One rod failed approximately 45 seconds after the reactor was shut down as a result of cladding embrittlement due to extensive cladding oxidation. Data are presented on the behavior of these irradiated fuel rods during steady-state operation, the power ramp, and film boiling operation. The effects of a power ramp and power ramp rates on pellet-cladding interaction are discussed. Test data are compared with FRAP-T3 computer model calculations and data from a previous Irradiation Effects test in which four irradiated fuel rods of a similar design were tested. Test IE-3 results indicate that the irradiated state of the fuel rods did not significantly affect fuel rod behavior during normal, abnormal (power ramp of 20 kW/m per minute), and accident (film boiling) conditions.

  7. 75 FR 1734 - Children’s Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines; i-SAFE...

    Science.gov (United States)

    2010-01-13

    ... Proposed Self-Regulatory Guidelines; i-SAFE, Inc. Application for Safe Harbor AGENCY: Federal Trade... for public comment concerning proposed self-regulatory guidelines submitted by i-SAFE, Inc. under the... approval self-regulatory guidelines that would implement the Rule's protections.\\3\\ \\1\\ 64 FR 59888 (1999...

  8. Therapeutic Assessment of Complex Trauma: A Single-Case Time-Series Study.

    Science.gov (United States)

    Tarocchi, Anna; Aschieri, Filippo; Fantini, Francesca; Smith, Justin D

    2013-06-01

    The cumulative effect of repeated traumatic experiences in early childhood incrementally increases the risk of adjustment problems later in life. Surviving traumatic environments can lead to the development of an interrelated constellation of emotional and interpersonal symptoms termed complex posttraumatic stress disorder (CPTSD). Effective treatment of trauma begins with a multimethod psychological assessment and requires the use of several evidence-based therapeutic processes, including establishing a safe therapeutic environment, reprocessing the trauma, constructing a new narrative, and managing emotional dysregulation. Therapeutic Assessment (TA) is a semistructured, brief intervention that uses psychological testing to promote positive change. The case study of Kelly, a middle-aged woman with a history of repeated interpersonal trauma, illustrates delivery of the TA model for CPTSD. Results of this single-case time-series experiment indicate statistically significant symptom improvement as a result of participating in TA. We discuss the implications of these findings for assessing and treating trauma-related concerns, such as CPTSD.

  9. Advisory group on transport package test standards. Vienna, 19-23 December 1977

    International Nuclear Information System (INIS)

    Ek, P.; Taylor, W.R.

    1978-03-01

    The IAEA convened the Advisory Group to (1) consider any available data on transport accidents and any risk assessments performed in Member States, with a view to making a critical study of the continuing adequacy of the package test requirements included in the current version of the IAEA Regulations for the Safe Transport of Radioactive Materials (Safety Series No.6, 1973 Revised Edition), and (2) make recommendations concerning the future planning and conduct of this study. The reports and recommendations are presented of the four working groups assigned, i.e., Statistical Data on Accidents and ''Near Accidents'', Incidents of Accidents and Risk Assessments, Review Package Testing Requirements, and Review Basis for the Radiation Levels for Packages

  10. Safeness of radiological machinery

    International Nuclear Information System (INIS)

    Yokoyama, Shun

    1979-01-01

    The human factors affecting the safeness of radiological machinery, which are often very big and complicated machines, are described from the stand point of handling. 20 to 50% of the troubles on equipments seem to be caused by men. This percentage will become even higher in highly developed equipments. Human factors have a great influence on the safeness of radiological equipments. As the human factors, there are sensory factors and knowledge factors as well as psychological factors, and the combination of these factors causes mishandling and danger. Medical services at present are divided in various areas, and consist of the teamwork of the people in various professions. Good human relationship, education and control are highly required to secure the safeness. (Kobatake, H.)

  11. The safety of electroconvulsive therapy and lithium in combination: a case series and review of the literature.

    Science.gov (United States)

    Dolenc, Tamara J; Rasmussen, Keith G

    2005-09-01

    Early reports cautioned against the combination of lithium and electroconvulsive therapy (ECT), citing risk of excessive cognitive disturbance, prolonged apnea, and spontaneous seizures. However, recent case series with larger numbers of patients indicate that the combination may be used safely and with optimal efficacy in certain clinical circumstances. In this report, we describe 12 patients in whom the combination of lithium and ECT was deemed safe. We also provide a comprehensive review of published literature and provide detailed recommendations for clinical practice.

  12. A generalized Grubbs-Beck test statistic for detecting multiple potentially influential low outliers in flood series

    Science.gov (United States)

    Cohn, T.A.; England, J.F.; Berenbrock, C.E.; Mason, R.R.; Stedinger, J.R.; Lamontagne, J.R.

    2013-01-01

    he Grubbs-Beck test is recommended by the federal guidelines for detection of low outliers in flood flow frequency computation in the United States. This paper presents a generalization of the Grubbs-Beck test for normal data (similar to the Rosner (1983) test; see also Spencer and McCuen (1996)) that can provide a consistent standard for identifying multiple potentially influential low flows. In cases where low outliers have been identified, they can be represented as “less-than” values, and a frequency distribution can be developed using censored-data statistical techniques, such as the Expected Moments Algorithm. This approach can improve the fit of the right-hand tail of a frequency distribution and provide protection from lack-of-fit due to unimportant but potentially influential low flows (PILFs) in a flood series, thus making the flood frequency analysis procedure more robust.

  13. Advisory Material for the IAEA Regulations for the Safe Transport of Radioactive Material (2012 Ed.). Specific Safety Guide

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-06-15

    This Safety Guide provides recommendations and guidance on achieving and demonstrating compliance with IAEA Safety Standards Series No. SSR-6, Regulations for the Safe Transport of Radioactive Material (2012 Edition), which establishes the requirements to be applied to the national and international transport of radioactive material. Transport is deemed to comprise all operations and conditions associated with and involved in the movement of radioactive material, including the design, fabrication and maintenance of packaging, and the preparation, consigning, handling, carriage, storage in transit and receipt at the final destination of packages. This publication supersedes IAEA Safety Standards Series No. TS-G-1.1 Rev. 1, which was issued in 2008.

  14. Treatment of severe lipophilic intoxications with intravenous lipid emulsion: a case series (2011–2014

    Directory of Open Access Journals (Sweden)

    Becker MD

    2017-10-01

    Full Text Available Michael D Becker, Brian C YoungEmergency and Critical Care, Animal Specialty Group, Los Angeles, CA, USAAbstract: The objective of this retrospective study was to describe the responses to treatment with intravenous lipid emulsion (ILE and the outcomes for a variety of severe intoxications. This case series includes 10 client-owned animals, 9 dogs and 1 cat, that underwent treatment with ILE for a variety of severe intoxications over a 4-year period. History, physical examination findings, clinical signs, clinicopathological test results, treatment, response to treatment, and outcome were recorded. Eight of the 10 patients survived to discharge. The toxicities included in this case series were baclofen, ivermectin and spinosad plus milbemycin oxime, baclofen and tadalafil, carbamate, methamphetamine, dextroamphetamine sulfate, amlodipine, bromethalin, and organophosphate. The two patients who died were intoxicated with bromethalin and an organophosphate. Six of the 10 patients developed lipemia secondary to ILE administration, and there were no other known adverse effects. Overall, ILE was a safe therapeutic option. This case series provides clinical evidence of successful treatment with ILE as an antidote for previously unpublished toxicities (amlodipine, carbamate, methamphetamine, and dextroamphetamine sulfate, additional evidence of success in treating baclofen and ivermectin toxicosis, as well as unsuccessful treatment of bromethalin and organophosphate toxicities.Keywords: intravenous lipid emulsion, toxicity, amlodipine 

  15. Research on the Safe Broadcasting of Television Program

    Directory of Open Access Journals (Sweden)

    Song Jin Bao

    2016-01-01

    Full Text Available The existing way of broadcasting and television monitoring has a lot of problems in China. On the basis of the signal technical indicators monitoring in the present broadcasting and television monitoring system, this paper further extends the function of the monitoring network in order to broaden the services of monitoring business and improve the effect and efficiency of monitoring work. The problem of identifying video content and channel in television and related electronic media is conquered at a low cost implementation way and the flexible technology mechanism. The coverage for video content and identification of the channel is expanded. The informative broadcast entries are generated after a series of video processing. The value of the numerous broadcast data is deeply excavated by using big data processing in order to realize a comprehensive, objective and accurate information monitoring for the safe broadcasting of television program.

  16. Online Learning of Safe Patient Transfers in Occupational Therapy Education

    Directory of Open Access Journals (Sweden)

    Cynthia L. Hayden D. H. Ed., OTR/L, CHT

    2013-02-01

    Full Text Available Online higher education is steadily increasing. For programs in allied health to be offered effectively in an elearning format, clinical psychomotor skills need to be addressed. The aim of this research was to design, implement, and evaluate an online safe patient transfers module for occupational therapy assistant (OTAstudents. The efficacy of teaching safe patient transfers in an e-learning environment was appraised using both quantitative and qualitative analysis. The applied research project was completed at a Tennessee community college. A convenience sample of eighteen students participated in the pilot study. Twenty-five studentsparticipated in the subsequent study. The instructional design of the course was based on Mager’s CriterionReferenced Instruction model. Streaming video was used as the delivery method for course material. A pretest/posttest evaluated the students’ cognitive knowledge of safe patient transfers. A behavioral transferscompetency checklist was used to rate videotapes of students’ performance of assisted stand pivot and dependent sliding board transfers. Research findings indicated students were able to learn this psychomotor clinical skill online with beginning proficiency. A paired t-test showed marked improvement of cognitive knowledge. A student learning survey revealed the majority of students preferred at least one hands-on classroom session where instructor feedback and interaction with classmates confirmed safe and effectiveclinical technique.

  17. Metabolic and Subjective Results Review of the Integrated Suit Test Series

    Science.gov (United States)

    Norcross, J.R.; Stroud, L.C.; Klein, J.; Desantis, L.; Gernhardt, M.L.

    2009-01-01

    Crewmembers will perform a variety of exploration and construction activities on the lunar surface. These activities will be performed while inside an extravehicular activity (EVA) spacesuit. In most cases, human performance is compromised while inside an EVA suit as compared to a crewmember s unsuited performance baseline. Subjects completed different EVA type tasks, ranging from ambulation to geology and construction activities, in different lunar analog environments including overhead suspension, underwater and 1-g lunar-like terrain, in both suited and unsuited conditions. In the suited condition, the Mark III (MKIII) EVA technology demonstrator suit was used and suit pressure and suit weight were parameters tested. In the unsuited conditions, weight, mass, center of gravity (CG), terrain type and navigation were the parameters. To the extent possible, one parameter was varied while all others were held constant. Tests were not fully crossed, but rather one parameter was varied while all others were left in the most nominal setting. Oxygen consumption (VO2), modified Cooper-Harper (CH) ratings of operator compensation and ratings of perceived exertion (RPE) were measured for each trial. For each variable, a lower value correlates to more efficient task performance. Due to a low sample size, statistical significance was not attainable. Initial findings indicate that suit weight, CG and the operational environment can have a large impact on human performance during EVA. Systematic, prospective testing series such as those performed to date will enable a better understanding of the crucial interactions of the human and the EVA suit system and their environment. However, work remains to be done to confirm these findings. These data have been collected using only unsuited subjects and one EVA suit prototype that is known to fit poorly on a large demographic of the astronaut population. Key findings need to be retested using an EVA suit prototype better suited to a

  18. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  19. Safe Cooperating Cyber-Physical Systems using Wireless Communication

    DEFF Research Database (Denmark)

    Pop, Paul; Scholle, Detlef; Sljivo, Irfan

    2017-01-01

    This paper presents an overview of the ECSEL project entitled ―Safe Cooperating Cyber-Physical Systems using Wireless Communication‖ (SafeCOP), which runs during the period 2016–2019. SafeCOP targets safety-related Cooperating Cyber-Physical Systems (CO-CPS) characterised by use of wireless...... detection of abnormal behaviour, triggering if needed a safe degraded mode. SafeCOP will also develop methods and tools, which will be used to produce safety assurance evidence needed to certify cooperative functions. SafeCOP will extend current wireless technologies to ensure safe and secure cooperation...

  20. Experimental analysis of the power curve sensitivity test series at ROSA-III

    International Nuclear Information System (INIS)

    Koizumi, Y.; Iriko, M.; Yonomoto, T.; Tasaka, K.

    1985-01-01

    The rig of safety assessment (ROSA)-III facility is a volumetrically scaled (1/424) boiling water reactor (BWR/6) system with an electrically heated core designed for integral LOCA and ECCS tests. Seven recirculation pump suction line break LOCA experiments were conducted at the ROSA-III facility in order to examine the effect of the initial stored heat of a fuel rod on the peak cladding temperature (PCT). The break size was changed from 200% to 5% in the test series and a failure of a high pressure core spray (HPCS) diesel generator was assumed. Three power curves which represented conservative, realistic and zero initial stored heat, respectively, were used. In a large break LOCA such as 200% or 50% breaks, the initial stored heat in a fuel rod has a large effect on the cladding surface temperature because core uncovery occurs before all the initial stored heat is released, whereas in a small break LOCA such as a 5% break little effect is observed because core uncovery occurs after the initial stored heat is released. The maximum PCTs for the conservative initial stored heat case was 925 K, obtained in the 50% break experiment, and that for the realistic initial stored heat case was 835 K, obtained in the 5% break experiment. (orig./HP)

  1. Regulations for the safe transport of radioactive material. 1985 ed. Supplement 1986

    International Nuclear Information System (INIS)

    1986-01-01

    Following a six-year effort, a major revision to the Agency's Regulations for the Safe Transport of Radioactive Material (Safety Series No. 6) was issued in 1985. In order to address minor problems with the 1985 Edition of Safety Series No. 6, a panel of experts convened by the International Atomic Energy Agency met from 13 to 17 January 1986. This panel considered minor inconsistencies, omissions or errors that had occurred in the course of preparing the 1985 Edition of Safety Series No. 6, and recommended that two types of change be made. First, changes which will correct errors in the presentation of the text, translation errors (in the French, Russian and Spanish versions of the 1985 Edition), and drafting which failed to express the intent of the panels which reviewed the previous edition of the Regulations; these minor changes are promulgated herewith by the authority of the Director General. Secondly, changes of detail which can only be introduced in accordance with the procedure approved by the Board of Governors on 22 September 1972, which authorizes the Director General to promulgate such changes after giving Governments not less than ninety days' notice and taking into account any comments that they make. Three changes of this second type were recommended by the panel, and were circulated according to the 'ninety-day rule' amendment procedure on 3 February 1986. Those changes which received unanimous support by Member States are included in this Supplement. Corrected text to the 1985 Edition of Safety Series No. 6 (paragraphs, tables, etc.) is provided in this Supplement, and this corrected text supersedes the corresponding portions of the 1985 Edition of Safety Series No. 6.

  2. Safe Re-use Practices in Wastewater-Irrigated Urban Vegetable Farming in Ghana

    DEFF Research Database (Denmark)

    Keraita, Bernard; Abaidoo, R.C; Beernaerts, I.

    2012-01-01

    of stakeholders at different levels along the food chain. This paper presents an overview of safe re-use practices including farm-based water treatment methods, water application techniques, post-harvest handling practices, and washing methods. The overview is based on a comprehensive analysis of the literature......Irrigation using untreated wastewater poses health risks to farmers and consumers of crop products, especially vegetables. With hardly any wastewater treatment in Ghana, a multiple-barrier approach was adopted and safe re-use practices were developed through action research involving a number...... and our own specific studies, which used data from a broad range of research methods and approaches. Identifying, testing, and assessment of safe practices were done with the active participation of key actors using observations, extensive microbiological laboratory assessments, and field...

  3. InaSAFE applications in disaster preparedness

    Science.gov (United States)

    Pranantyo, Ignatius Ryan; Fadmastuti, Mahardika; Chandra, Fredy

    2015-04-01

    Disaster preparedness activities aim to reduce the impact of disasters by being better prepared to respond when a disaster occurs. In order to better anticipate requirements during a disaster, contingency planning activities can be undertaken prior to a disaster based on a realistic disaster scenario. InaSAFE is a tool that can inform this process. InaSAFE is a free and open source software that estimates the impact to people and infrastructure from potential hazard scenarios. By using InaSAFE, disaster managers can develop scenarios of disaster impacts (people and infrastructures affected) to inform their contingency plan and emergency response operation plan. While InaSAFE provides the software framework exposure data and hazard data are needed as inputs to run this software. Then InaSAFE can be used to forecast the impact of the hazard scenario to the exposure data. InaSAFE outputs include estimates of the number of people, buildings and roads are affected, list of minimum needs (rice and clean water), and response checklist. InaSAFE is developed by Indonesia's National Disaster Management Agency (BNPB) and the Australian Government, through the Australia-Indonesia Facility for Disaster Reduction (AIFDR), in partnership with the World Bank - Global Facility for Disaster Reduction and Recovery (GFDRR). This software has been used in many parts of Indonesia, including Padang, Maumere, Jakarta, and Slamet Mountain for emergency response and contingency planning.

  4. Pre-test evaluation of LLTR series II Test A-7

    International Nuclear Information System (INIS)

    Knittle, D.

    1981-03-01

    The purpose of this report is to present pre-test predictions of pressure histories for the A-7 test to be conducted in the Large Leak Test Rig (LLTR) at the Energy Technology Engineering Center (ETEC) in April 1981

  5. Engineering safe and secure cyber-physical systems the specification PEARL approach

    CERN Document Server

    Gumzej, Roman

    2016-01-01

    This book introduces the concept of holistic design and development of cyber physical systems to achieve their safe and secure operation. It shows that by following the standards for embedded system’s safety and using appropriate hardware and software components inherently safe system’s architectures can be devised and certified. While the standards already enable testing and certification of inherently safe and sound hardware, this is still not the case with software. The book demonstrates that Specification PEARL(SPEARL) addresses this issue and proposes appropriate solutions from the viewpoints of software engineering as well as concrete program components. By doing so it reduces the complexity of cyber physical systems design in an innovative way. Three ultimate goals are being followed in the course of defining this new PEARL standard, namely: 1. simplicity over complexity, 2. inherent real-time ability, and 3. conformity to safety integrity and security capability levels.

  6. Pre-test evaluation of LLTR Series II Test A-6

    International Nuclear Information System (INIS)

    Knittle, D.

    1980-11-01

    Purpose of this report is to present pre-test predictions of pressure histories for the A6 test to be conducted in the Large Leak Test Facility (LLTF) at the Energy Technology Engineering Center. A6 is part of a test program being conducted to evaluate the effects of leaks produced by a double-ended guillotine rupture of a single tube. A6 will provide data on the CRBR prototypical double rupture disc performance

  7. Third meeting of the advisory group for the comprehensive review of the IAEA regulations for the safe transport of radioactive materials, Vienna, 7-11 November 1983

    International Nuclear Information System (INIS)

    Rawl, R.R.

    This meeting was the third and final planned stage in the process to revise the Agency's Regulations for the Safe Transport of Radioactive Materials, Safety Series No. 6. Its task was to consider comments which had been submitted in response to the Agency's circulation of the third draft revision of Safety Series No. 6 and to make any necessary changes to the draft that the Advisory Group felt were necessary

  8. Safe Minimum Internal Temperature Chart

    Science.gov (United States)

    ... Internal Temperature Chart Safe steps in food handling, cooking, and storage are essential in preventing foodborne illness. You can't see, smell, or taste harmful bacteria that may cause illness. In every step of food preparation, follow the four guidelines to keep food safe: ...

  9. Finding Sums for an Infinite Class of Alternating Series

    Science.gov (United States)

    Chen, Zhibo; Wei, Sheng; Xiao, Xuerong

    2012-01-01

    Calculus II students know that many alternating series are convergent by the Alternating Series Test. However, they know few alternating series (except geometric series and some trivial ones) for which they can find the sum. In this article, we present a method that enables the students to find sums for infinitely many alternating series in the…

  10. Can nuclear waste be stored safely at Yucca mountain?

    International Nuclear Information System (INIS)

    Whipple, C.G.

    1996-01-01

    In 1987 the federal government narrowed to one its long-term options for disposing of nuclear waste: storing it permanently in a series of caverns excavated out of the rock deep below Yucca mountain in southern Nevada. Whether it makes sense at this time to dispose permanently of spent fuel and radioactive waste in a deep geologic repository is hotly disputed. But the Nuclear Waste Policy Act amendements of 1987 decree that waste be consolidated in Yucca Mountain if the mountain is found suitable. Meanwhile the spent fuel continues to pile up across the country, and 1998 looms, adding urgency to the question: What can science tell us about the ability of the mountain to store nuclear waste safely? This paper discusses this issue and describes how studies of the mountain's history and geology can contribute useful insights but not unequivocal conclusions

  11. Implementation of the NANoREG Safe-by-Design approach for different nanomaterial applications

    International Nuclear Information System (INIS)

    Micheletti, C; Roman, M; Tedesco, E; Olivato, I; Benetti, F

    2017-01-01

    The Safe-by-Design (SbD) concept is already in use in different industrial sectors as an integral part of the innovation process management. However, the adopted approach is often limited to design solutions aiming at hazard reduction. Safety is not always considered during the innovation process, mainly due to the lack of knowledge (e.g. in small and medium companies, SMEs) and the lack of dialogue between actors along the innovation chain. The net result is that safety is considered only at the end of the innovation process at the market authorization phase, with potential loss of time and money. This is especially valid for manufactured nanomaterials (MNM) for which the regulatory context is not completely developed, and the safety knowledge is not readily available. In order to contribute to a sustainable innovation process in the nanotechnology field by maximising both benefits and safety, the NANoREG project developed a Safe Innovation approach, based on two elements: the Safe-by-Design approach which aims at including risk assessment into all innovation stages; and the Regulatory Preparedness, focused on the dialogue with stakeholders along the innovation chain. In this work we present some examples about the implementation in our Laboratory of this approach for different MNM applications, covering different steps of the innovation chain. The case studies include: the feasibility study of a medical device including substances, for topical application; the testing of two potential nanotech solutions for the consolidation of cultural heritage artifacts; the testing of coatings already on the market for other uses, which was tested as food contact materials (FCM) to evaluate the conformity to food applications. These three examples represent a good opportunity to show the importance of NANoREG SbD and Safe Innovation Approach in general, for developing new nanotechnology-based products, also highlighting the crucial role of EU ProSafe project in promoting this

  12. Implementation of the NANoREG Safe-by-Design approach for different nanomaterial applications

    Science.gov (United States)

    Micheletti, C.; Roman, M.; Tedesco, E.; Olivato, I.; Benetti, F.

    2017-06-01

    The Safe-by-Design (SbD) concept is already in use in different industrial sectors as an integral part of the innovation process management. However, the adopted approach is often limited to design solutions aiming at hazard reduction. Safety is not always considered during the innovation process, mainly due to the lack of knowledge (e.g. in small and medium companies, SMEs) and the lack of dialogue between actors along the innovation chain. The net result is that safety is considered only at the end of the innovation process at the market authorization phase, with potential loss of time and money. This is especially valid for manufactured nanomaterials (MNM) for which the regulatory context is not completely developed, and the safety knowledge is not readily available. In order to contribute to a sustainable innovation process in the nanotechnology field by maximising both benefits and safety, the NANoREG project developed a Safe Innovation approach, based on two elements: the Safe-by-Design approach which aims at including risk assessment into all innovation stages; and the Regulatory Preparedness, focused on the dialogue with stakeholders along the innovation chain. In this work we present some examples about the implementation in our Laboratory of this approach for different MNM applications, covering different steps of the innovation chain. The case studies include: the feasibility study of a medical device including substances, for topical application; the testing of two potential nanotech solutions for the consolidation of cultural heritage artifacts; the testing of coatings already on the market for other uses, which was tested as food contact materials (FCM) to evaluate the conformity to food applications. These three examples represent a good opportunity to show the importance of NANoREG SbD and Safe Innovation Approach in general, for developing new nanotechnology-based products, also highlighting the crucial role of EU ProSafe project in promoting this

  13. Recommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series

    DEFF Research Database (Denmark)

    Bruze, Magnus; Andersen, Klaus Ejner; Goossens, An

    2008-01-01

    various European centres when tested in consecutive dermatitis patients. CONCLUSIONS: From 2008, pet. preparations of fragrance mix 2 at 14% w/w (5.6 mg/cm(2)) and hydroxyisohexyl 3-cyclohexene carboxaldehyde at 5% w/w (2.0 mg/cm(2)) are recommended for inclusion in the baseline series. With the Finn...

  14. Verifying seismic design of nuclear reactors by testing. Volume 1: test plan

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-20

    This document sets forth recommendations for a verification program to test the ability of operational nuclear power plants to achieve safe shutdown immediately following a safe-shutdown earthquake. The purpose of the study is to develop a program plan to provide assurance by physical demonstration that nuclear power plants are earthquake resistant and to allow nuclear power plant operators to (1) decide whether tests should be conducted on their facilities, (2) specify the tests that should be performed, and (3) estimate the cost of the effort to complete the recommended test program.

  15. Verifying seismic design of nuclear reactors by testing. Volume 1: test plan

    International Nuclear Information System (INIS)

    1979-01-01

    This document sets forth recommendations for a verification program to test the ability of operational nuclear power plants to achieve safe shutdown immediately following a safe-shutdown earthquake. The purpose of the study is to develop a program plan to provide assurance by physical demonstration that nuclear power plants are earthquake resistant and to allow nuclear power plant operators to (1) decide whether tests should be conducted on their facilities, (2) specify the tests that should be performed, and (3) estimate the cost of the effort to complete the recommended test program

  16. Steering teens safe: a randomized trial of a parent-based intervention to improve safe teen driving.

    Science.gov (United States)

    Peek-Asa, Corinne; Cavanaugh, Joseph E; Yang, Jingzhen; Chande, Vidya; Young, Tracy; Ramirez, Marizen

    2014-07-31

    Crashes are the leading cause of death for teens, and parent-based interventions are a promising approach. We assess the effectiveness of Steering Teens Safe, a parent-focused program to increase safe teen driving. Steering Teens Safe aimed to improve parental communication with teens about safe driving using motivational interviewing techniques in conjunction with 19 safe driving lessons. A randomized controlled trial involved 145 parent-teen dyads (70 intervention and 75 control). Intervention parents received a 45-minute session to learn the program with four follow-up phone sessions, a DVD, and a workbook. Control parents received a standard brochure about safe driving. Scores were developed to measure teen-reported quantity and quality of parental communication about safe driving. The main outcome measure was a previously validated Risky Driving Score reported by teens. Because the Score was highly skewed, a generalized linear model based on a gamma distribution was used for analysis. Intervention teens ranked their parent's success in talking about driving safety higher than control teens (p = 0.035) and reported that their parents talked about more topics (non-significant difference). The Risky Driving Score was 21% lower in intervention compared to control teens (85% CI = 0.60, 1.00). Interaction between communication quantity and the intervention was examined. Intervention teens who reported more successful communication had a 42% lower Risky Driving Score (95% CI = 0.37, 0.94) than control parents with less successful communication. This program had a positive although not strong effect, and it may hold the most promise in partnership with other programs, such as Driver's Education or Graduated Driver's License policies. ClinicalTrials.gov NCT01014923. Registered Nov. 16, 2009.

  17. Staying Safe in the Water

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dr. Julie Gilchrist, a pediatrician and medical epidemiologist from CDC’s Injury Center, talks about staying safe in the water. Tips are for all audiences, with a focus on preventing drownings and keeping children safe in and around the pool, lake, or ocean.

  18. Safe Operation of Critical Assemblies and Research Reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1961-05-15

    This Manual is provided as a guide to the safe operation of critical assemblies and small research reactors. It is intended that it should be used by all authorities and persons concerned with, or responsible for, the use of such equipment, in addition to the scientists and technologists who are actually working with, or operating it. It is suggested that it will be of use to those wishing to design and manufacture, or purchase, critical assemblies or research reactors, as well as those already in possession of them, and that it will prove particularly helpful to those users who have no direct access to other collected sources of information. This Manual is not a set of rules or a code of practice, but a series of recommendations which must be interpreted with scientific judgement in their application to any particular problem. The guiding principles are given from which good operational procedures may be established and improved. The promulgation of rigid standards is both impossible and undesirable at the present time, since the topics discussed form part of a rapidly growing science and technology. Therefore, any recommendations made should not be used to restrict or inhibit future developments. The Manual is intended mainly for use in those Member States where there has been little experience in the operation of critical assemblies and research reactors. It has been compounded from the best practices which exist in Member States having a large amount of such experience, so that nothing in it should conflict with the best practices to be encountered in the field of safe operation.

  19. Safe Operation of Critical Assemblies and Research Reactors

    International Nuclear Information System (INIS)

    1961-01-01

    This Manual is provided as a guide to the safe operation of critical assemblies and small research reactors. It is intended that it should be used by all authorities and persons concerned with, or responsible for, the use of such equipment, in addition to the scientists and technologists who are actually working with, or operating it. It is suggested that it will be of use to those wishing to design and manufacture, or purchase, critical assemblies or research reactors, as well as those already in possession of them, and that it will prove particularly helpful to those users who have no direct access to other collected sources of information. This Manual is not a set of rules or a code of practice, but a series of recommendations which must be interpreted with scientific judgement in their application to any particular problem. The guiding principles are given from which good operational procedures may be established and improved. The promulgation of rigid standards is both impossible and undesirable at the present time, since the topics discussed form part of a rapidly growing science and technology. Therefore, any recommendations made should not be used to restrict or inhibit future developments. The Manual is intended mainly for use in those Member States where there has been little experience in the operation of critical assemblies and research reactors. It has been compounded from the best practices which exist in Member States having a large amount of such experience, so that nothing in it should conflict with the best practices to be encountered in the field of safe operation.

  20. Safe biodegradable fluorescent particles

    Science.gov (United States)

    Martin, Sue I [Berkeley, CA; Fergenson, David P [Alamo, CA; Srivastava, Abneesh [Santa Clara, CA; Bogan, Michael J [Dublin, CA; Riot, Vincent J [Oakland, CA; Frank, Matthias [Oakland, CA

    2010-08-24

    A human-safe fluorescence particle that can be used for fluorescence detection instruments or act as a safe simulant for mimicking the fluorescence properties of microorganisms. The particle comprises a non-biological carrier and natural fluorophores encapsulated in the non-biological carrier. By doping biodegradable-polymer drug delivery microspheres with natural or synthetic fluorophores, the desired fluorescence can be attained or biological organisms can be simulated without the associated risks and logistical difficulties of live microorganisms.

  1. Safe Haven.

    Science.gov (United States)

    Bush, Gail

    2003-01-01

    Discusses school libraries as safe havens for teenagers and considers elements that foster that atmosphere, including the physical environment, lack of judgments, familiarity, leisure, and a welcoming nature. Focuses on the importance of relationships, and taking the time to listen to teens and encourage them. (LRW)

  2. Safe Handling of Radioisotopes. Health Physics Addendum

    Energy Technology Data Exchange (ETDEWEB)

    Appleton, G J; Krishnamoorthy, P N

    1960-07-15

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains technical information necessary for the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the technical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  3. Safe Handling of Radioisotopes. Health Physics Addendum

    International Nuclear Information System (INIS)

    Appleton, G.J.; Krishnamoorthy, P.N.

    1960-01-01

    The International Atomic Energy Agency published in 1958 a Manual entitled ''Safe Handling of Radioisotopes'' (Safety Series No. 1 - STI/PUB/1), based on the work of an international panel convened by the Agency. As recommended by that panel and approved by the Agency's Board of Governors, this Addendum has now been prepared, primarily as a supplement to the Manual. It contains technical information necessary for the implementation of the controls given in the Manual. In addition, it is intended to serve as a brief introduction to the technical problems encountered in radiological protection work and to the methods of resolving them. As in the case of the Manual itself, the information given in this Addendum is particularly relevant to the problems encountered by the small user of radioisotopes. Although the basic principles set forth in it apply to all work with radiation sources, the Addendum is not intended to serve as a radiological protection manual for use in reactor installations or large-scale nuclear industry, where more specialized techniques and information are required.

  4. Safe transport of radioactive material. Second edition

    International Nuclear Information System (INIS)

    1996-01-01

    In 1991, the International Atomic Energy Agency published Training Course Series No. 1 (TCS-1), a training manual that provides in 20 chapters a detailed discussion of the background, philosophy, technical bases and requirements and implementation aspects of the Regulations for the Safe Transport of Radioactive Material. The Transport Regulations are widely implemented by the IAEA's Member States and are also used as the bases for radioactive material transport requirements of modal organisations such as the International Maritime Organization and the International Civil Aviation Organization. This document is a supplement of TCS-1 to provide additional material in the form of learning aids and new exercises, that have been developed with the use of TCS-1 at succeeding IAEA training courses. The learning aids in the first part of the supplement are hitherto unpublished material that provide detailed guidance useful in solving the exercises presented in the second part. Solutions to the exercises are on field at the IAEA Secretariat and are available by arrangement to lectures presenting IAEA training courses. 4 refs, 1 fig., 6 tabs

  5. The amended regulations for the safe transport of radioactive materials in Japan

    International Nuclear Information System (INIS)

    Takemura, Yoshio

    1978-01-01

    To cope with the inadequacies of the laws and regulations including the Law Concerning Prevention of Radiation Injuries Due to Radioisotopes, Etc., the Amended Regulations for the Safe Transport of Radioactive Materials in Japan has been issued. It is based on the Regulations of IAEA for the Safe Transport of Radioactive Materials and the Technical Standards for the Transport of Radioactive Materials decided by the AEC of Japan. In the amended regulations, emphasis is placed on the safety design of transporting goods. They are classified in Types L, A and B according to shock resistance and fire resistance, and the quantities of radioisotopes allowed to be contained in respective types are specified. The following matters are described: basic ideas concerning the types of transporting goods, test standards for the goods, transport standards for the goods, and nondestructive test apparatuses in transport. (Mori, K.)

  6. How safe is safe enough?

    International Nuclear Information System (INIS)

    Desnoyers, B.; Chanzy, Y.

    2004-01-01

    The IAEA Regulations for the Safe Transport of Radioactive Material, were historically established with the objective to reduce the probability that persons be exposed to unacceptable doses due to normal operation or accident situations during transport of radioactive material. Based on the International Basic Safety Standards for Protection against Ionizing Radiation (BSS), the definition, which was adopted for an unacceptable dose for an accident situation, is the excess of the maximum dose limits permissible in a single year for the occupational exposure of a worker in the BSS. Concerning the severity of accident situations, it has always be clearly stated that the objective of the tests for demonstrating ability to withstand accident conditions of transport was not to cover every accident condition, but solely most of them. The last available evaluations regarding the rate of accidents which are covered by the standardised accident conditions of transport defined in the IAEA Regulations give a range of about 80%, plus or minus 15% which depends on transport mode and studies. Consequently, slight variations in the capabilities of the packages to meet the specified performance would probably not have significant consequences on the protection level in case of accident. In the assessment of the compliance with the regulations, the tendency of experts, taking advantage of the enhanced performances of computer calculation codes, is to ask more and more calculations, with more and more accuracy, leading to more and more restrictions. Consequently, cost and delay are considerably increased without any evidence of an equivalent effect on the level of protection. This paper will initiate a reflection on the general objectives and principles when implementing the Regulations, in such a way that demonstrations remain cost effective, taking into account evolution of the techniques and a high level of safety

  7. More than a Safe Space

    Science.gov (United States)

    Sadowski, Michael

    2016-01-01

    Over the past three decades, much of the conversation about LGBTQ students in schools has centered on safety--anti-bullying policies, the "safe space" of gay-straight alliances, and "safe zones" marked by rainbow-colored stickers on classroom doors. In this article, Michael Sadowski argues that it's time to move beyond safety…

  8. Homogenization of Portuguese long-term temperature data series: Lisbon, Coimbra and Porto

    Directory of Open Access Journals (Sweden)

    A. L. Morozova

    2012-12-01

    Full Text Available Three long-term temperature data series measured in Portugal were studied to detect and correct non-climatic homogeneity breaks and are now available for future studies of climate variability.

    Series of monthly minimum (Tmin and maximum (Tmax temperatures measured in the three Portuguese meteorological stations of Lisbon (from 1856 to 2008, Coimbra (from 1865 to 2005 and Porto (from 1888 to 2001 were studied to detect and correct non-climatic breaks. These series, together with monthly series of average temperature (Taver and temperature range (DTR derived from them, were tested in order to detect breaks, using firstly metadata, secondly a visual analysis, and thirdly four widely used homogeneity tests: von Neumann ratio test, Buishand test, standard normal homogeneity test, and Pettitt test. The homogeneity tests were used in absolute (using temperature series themselves and relative (using sea-surface temperature anomalies series obtained from HadISST2.0.0.0 close to the Portuguese coast or already corrected temperature series as reference series modes. We considered the Tmin, Tmax and DTR series as most informative for the detection of breaks due to the fact that Tmin and Tmax could respond differently to changes in position of a thermometer or other changes in the instrument's environment; Taver series have been used mainly as control.

    The homogeneity tests showed strong inhomogeneity of the original data series, which could have both internal climatic and non-climatic origins. Breaks that were identified by the last three mentioned homogeneity tests were compared with available metadata containing data such as instrument changes, changes in station location and environment, observation procedures, etc. Significant breaks (significance 95% or more that coincided with known dates of

  9. UAS Integration in the NAS Project: Integrated Test and Evaluation (IT&E) Flight Test 3. Revision E

    Science.gov (United States)

    Marston, Michael

    2015-01-01

    The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and

  10. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  11. Procedure of safe handling with cytostatic drugs

    Directory of Open Access Journals (Sweden)

    Kodžo Dragan

    2003-01-01

    Full Text Available Working group for safe handling with cytostatic drugs has been formed by the Ministry of Health, and it consists of professionals from IORS, Federal Bureau of Weights and Measures, Industrial Medicine, Institute of Hematology, Military Medical Academy, and Crown Agents. The aim of this working group is to prepare procedures for safe handling with cytostatic drugs, as well as program for educational seminar for nurses, medical technicians, and pharmaceutical technicians. The procedures will serve as a guide of good practice of oncology health care, and will refer to all actions that health care professionals carry out from the moment of drugs arrival to the pharmacy to the moment of their application. In the first segment of this procedure, general rules are given for working with cytotoxic agents, control for risky exposures, safe system of work, control of working environment, monitoring of the employees' health condition adequate protection in the working environment, protective equipment of the employees (gloves, mask, cap, eyeglasses, shoe covers, coats and chambers for vertical laminary air stream. Storing of cytostatics, procedure in case of accident, and waste handling and removal are also described in this segment. Fifty-three standard operational procedures are described in detail in the second segment. Training scheme for preparation of chemotherapy is given in the third segment - education related to various fields and practical part, which would be carried out through workshops, and at the end of the course participants would pass a test and obtain certificate. After the procedures for safe handling with cytostatics are legally regulated employer will have to provide minimum of protective equipment, special rooms for the drugs dissolving, chambers with laminar airflow, 6 hours working time, rotation of the staff working with drugs dissolving in intervals of every five years, higher efficiency, better health control. In conclusion

  12. Managing Cassini Safe Mode Attitude at Saturn

    Science.gov (United States)

    Burk, Thomas A.

    2010-01-01

    The Cassini spacecraft was launched on October 15, 1997 and arrived at Saturn on June 30, 2004. It has performed detailed observations and remote sensing of Saturn, its rings, and its satellites since that time. In the event safe mode interrupts normal orbital operations, Cassini has flight software fault protection algorithms to detect, isolate, and recover to a thermally safe and commandable attitude and then wait for further instructions from the ground. But the Saturn environment is complex, and safety hazards change depending on where Cassini is in its orbital trajectory around Saturn. Selecting an appropriate safe mode attitude that insures safe operation in the Saturn environment, including keeping the star tracker field of view clear of bright bodies, while maintaining a quiescent, commandable attitude, is a significant challenge. This paper discusses the Cassini safe table management strategy and the key criteria that must be considered, especially during low altitude flybys of Titan, in deciding what spacecraft attitude should be used in the event of safe mode.

  13. Antidiabetic Activity Test of Ethanolic Seri Leave’s (Muntingia Calabura L. Extract in Male Rats Induced by Alloxan

    Directory of Open Access Journals (Sweden)

    Herlina Herlina

    2018-01-01

    Full Text Available Antidiabetic activity test of ethanol extract of seri leave (Muntingia calabura L. rats induced by alloxan has been done. Male wistar albino rats are used as animal models which divided into 6 groups, normal group (aquadest, negative control group (Na CMC 0,5%, positive control group (glibenclamide 0,43 mg/200 gBB, and 1, 2, and 3 treatment groups (ethanol extract of seri leave 65, 130, dan 260 mg/kgBB. Rats blood glucose level after induced intraperitoneally by alloxan 130 mg/kgBB can be stated as diabetes when >200 mg/dL. Preprandial blood glucose levels are measured using DTN-410-K photometer, on day 0, 5, 10, and 15. The average result of AUC0-15 and percentage of decreasing blood glucose level for positive control group are 2732,5 and 37,43%, and 3 treatment groups (65 mg/kgBB, 130 mg/kgBB, and 260 mg/kgBB 3105 and 28,90%; 2962,5 and 32,16%; 2810 and 35,66%. This point indicated that the ethanol extract of seri leave has an antidiabetic activity and there is no significant difference compared with glibenclamide (p<0,05. Percentage of blood glucose decrease level the third treatment group there is no significant difference compare with positive control group. According to the relation between percentage of blood glucose decrease level with dose, value of ED50 of ethanol extract of seri leave is 692,424 mg/kgBB.

  14. A retrospective study of 2585 patients patch tested with the European standard series in Hong Kong (1995-99).

    Science.gov (United States)

    Lam, Wai Sun; Chan, Loi Yuen; Ho, Stanley Ching Kong; Chong, Lai Yin; So, Win Han; Wong, Tze Wai

    2008-02-01

    Data on patch test findings in Hong Kong are scarce, with the last survey performed more than 10 years ago. A retrospective analysis of results from all patch tests performed on patients with suspected allergic contact dermatitis from January 1995 to December 1999 in the Social Hygiene Service, which provides a public dermatology service in Hong Kong, was undertaken. We aimed to explore the demographic data associated with positive reactions and the profile of contact sensitizing allergens in Hong Kong. A total of 2585 patients were patch tested with the European standard series during the period. Most were Chinese, with a female-to-male ratio of 3 : 2. One or more positive responses were noted in 1415 patients (54.7%). The most common allergen was nickel sulfate (24.4%), followed by fragrance mix (13.7%), cobalt chloride (8.7%), p-phenylenediamine (6.0%), and balsam of Peru (5.7%). Nickel sensitivity was more common in female patients, and dichromate sensitivity was more common in male patients (P history were significant risk factors for nickel sensitivity. This study provides a profile of allergens responsible for allergic contact dermatitis in the public dermatology service in Hong Kong. A prospective study, using a larger panel of allergens, involving patients from both the private and public sectors, would provide a more comprehensive profile of contact allergens in Hong Kong and contribute to the establishment of a local standard series.

  15. General-purpose heat source safety verification test series: SVT-11 through SVT-13

    International Nuclear Information System (INIS)

    George, T.G.; Pavone, D.

    1986-05-01

    The General-Purpose Heat Source (GPHS) is a modular component of the radioisotope thermoelectric generator that will provide power for the Galileo and Ulysses (formerly ISPM) space missions. The GPHS provides power by transmitting the heat of 238 Pu α-decay to an array of thermoelectric elements. Because the possibility of an orbital abort always exists, the heat source was designed and constructed to minimize plutonia release in any accident environment. The Safety Verification Test (SVT) series was formulated to evaluate the effectiveness of GPHS plutonia containment after atmospheric reentry and Earth impact. The first two reports (covering SVT-1 through SVT-10) described the results of flat, side-on, and angular module impacts against steel targets at 54 m/s. This report describes flat-on module impacts against concrete and granite targets, at velocities equivalent to or higher than previous SVTs

  16. Critical heat flux tests for a 12 finned-element assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J., E-mail: Jun.Yang@cnl.ca; Groeneveld, D.C.; Yuan, L.Q.

    2017-03-15

    Highlights: • CHF tests for a 12 finned-fuel-element assembly at highly subcooled conditions. • Test approach to maximize experimental information and minimize heater failures. • Three series of tests were completed in vertical upward light water flow. • Bundle simulators of two axial power profiles and three heated lengths were tested. • Results confirm that the prediction method predicts lower CHF values than measured. - Abstract: An experimental study was undertaken to provide relevant data to validate the current critical heat flux (CHF) prediction method of the NRU driver fuel for safety analysis, i.e., to confirm no CHF occurrence below the predicted values. The NRU driver fuel assembly consists of twelve finned fuel elements arranged in two rings – three in the inner ring and nine in the outer ring. To satisfy the experimental objective tests at very high heat fluxes, very high mass velocities, and high subcoolings were conducted where the CHF mechanism is the departure from nucleate boiling (DNB). Such a CHF experiment can be very difficult, costly and time consuming since failure of the heating surface due to rupture or melting (physical burnout) is expected when the DNB type of CHF is reached. A novel experimental approach has been developed to maximize the amount of relevant experimental information on safe operating conditions in the tests, and to minimize any possible heater failures that inherently accompany the CHF occurrence at these conditions. Three series of tests using electrically heated NRU driver fuel simulators with three heated lengths and two axial power profiles (or axial heat flux distribution (AFD)) were completed in vertical upward light water flow. Each series of tests covered two mass flow rates, several heat flux levels, and local subcoolings that bound the ranges of interest for the analysis of postulated slow loss-of-regulation accident (LORA) and loss-of-flow accident (LOFA) scenarios. Tests for each mass flow rate of

  17. A Hybrid Joint Moment Ratio Test for Financial Time Series

    NARCIS (Netherlands)

    P.A. Groenendijk (Patrick); A. Lucas (André); C.G. de Vries (Casper)

    1998-01-01

    textabstractWe advocate the use of absolute moment ratio statistics in conjunction with standard variance ratio statistics in order to disentangle linear dependence, non-linear dependence, and leptokurtosis in financial time series. Both statistics are computed for multiple return horizons

  18. Oral Challenge without Skin Testing Safely Excludes Clinically Significant Delayed-Onset Penicillin Hypersensitivity.

    Science.gov (United States)

    Confino-Cohen, Ronit; Rosman, Yossi; Meir-Shafrir, Keren; Stauber, Tali; Lachover-Roth, Idit; Hershko, Alon; Goldberg, Arnon

    Penicillins are the drug family most commonly associated with hypersensitivity reactions. Current guidelines recommend negative skin tests (ST) before re-administering penicillins to patients with previous nonimmediate reactions (NIR). The objective of this study was to examine whether ST are necessary before re-administering penicillin to patients with NIR. Patients with NIR to penicillins starting longer than 1 hour after last dose administration or starting any time after the first treatment day or patients with vague recollection of their reaction underwent penicillin ST. Disregarding ST results, patients were challenged with the relevant penicillins. One-tenth of the therapeutic dose followed by the full dose was administered at 1-hour interval and patients continued taking the full dose for 5 days. A total of 710 patients with alleged BL allergy were evaluated. Patients with a history of immediate reaction (52, 7.3%) or cephalosporin allergy (16, 2.2%) were excluded. Of the remaining 642 patients, 62.3% had negative ST, 5.3% positive ST, and 32.4% equivocal ST. A total of 617 (96.1%) patients were challenged. Immediate reaction was observed in 9 patients (1.5%): 1-positive ST, 7-negative ST, and 1-equivocal ST (P = .7). Late reaction to the first-day challenge occurred in 24 patients (4%). An at-home challenge was continued by 491 patients. Complete 5-day and partial challenges were well tolerated by 417 (85%) and 44 patients (8.9%), respectively, disregarding ST results. Thirty patients (6.1%) developed mild reactions to the home challenge regardless of their ST results. A 5-day oral challenge without preceding ST is safe and sufficient to exclude penicillin allergy after NIR developing during penicillin treatment. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  19. Inherently safe light water reactors

    International Nuclear Information System (INIS)

    Ise, Takeharu

    1987-01-01

    Today's large nuclear power reactors of world-wise use have been designed based on the philosophy. It seems that recent less electricity demand rates, higher capital cost and the TMI accident let us acknowledge relative small and simplified nuclear plants with safer features, and that Chernobyl accident in 1983 underlines the needs of intrinsic and passive safety characteristics. In such background, several inherently safe reactor concepts have been presented abroad and domestically. First describing 'Can inherently safe reactors be designed,' then I introduce representative reactor concepts of inherently safe LWRs advocated abroad so far. All of these innovative reactors employ intrinsic and passive features in their design, as follows: (1) PIUS, an acronym for Process Inherent Ultimate Safety, or an integral PWR with passive heat sink and passive shutdown mechanism, advocated by ASEA-ATOM of Sweden. (2) MAP(Minimum Attention Plant), or a self-pressurized, natural circulation integral PWR, promoted by CE Inc. of the U.S. (3) TPS(TRIGA Power System), or a compact PWR with passive heat sink and inherent fuel characteristics of large prompt temperature coefficient, prompted by GA Technologies Inc. of the U.S. (4) PIUS-BWR, or an inherently safe BWR employing passively actuated fluid valves, in competition with PIUS, prompted by ORNL of the U.S. Then, I will describe the domestic trends in Japan and the innovative inherently safe LWRs presented domestically so far. (author)

  20. Fragmentation of Solid Materials Using Shock Tubes. Part 2: First Test Series in a Large Diameter Shock Tube

    Science.gov (United States)

    2017-12-01

    series used improved experimental techniques to reduce obscuration due to smoke and fire which, again, increased the number of observed fragments (iii...minimally-reinforced concrete masonry unit (CMU) wall, and one 8-ft x 8-ft reinforced concrete panel, each carefully fabricated and mounted to replicate...develops a vertical compressive force that resists horizontal flexure. Figure 4. A view of CMU sample set-up used in Test 20. 6 Figure 5

  1. Pediatric Digital Necrosis Secondary to Dressing Application: A Case Series.

    Science.gov (United States)

    Bjorklund, Kim A; Rice, Dahlia M; Amalfi, Ashley N

    2018-04-01

    Pediatric digital necrosis resulting in revision amputation is a devastating outcome following digital dressing application. We report a series of 4 pediatric patients (age: 21 months-11 years) who presented for surgical consultation related to digital ischemia and irreversible necrosis following the application of Coban digital dressings. A review of the literature demonstrated that such injuries had not previously been described. In our case series, Coban dressing was utilized as a deterrent for thumb sucking, fingertip tuft fractures with nail bed lacerations, and a phalanx fracture secondary to crush injury. All 4 children suffered digital necrosis secondary to Coban dressings and ultimately required revision amputation. We discuss risks factors, application practices, and strategies to minimize complications with digital dressings in the pediatric population with the intent of creating awareness among hand surgeons to help promote safe practices and improve patient outcomes.

  2. Dementia - keeping safe in the home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000031.htm Dementia - keeping safe in the home To use the ... make sure the homes of people who have dementia are safe for them. Safety Tips for the ...

  3. Role IAEA implementation of ICRP-60 on regulations the safe transport of radioactive material

    International Nuclear Information System (INIS)

    Elshinawy, R.K.M.; Gomaa, M.A.

    1994-01-01

    In november 1990, the (ICRP) adopted its 1990 recommendations (ICRP-60) ( 1). These recommendations will significantly influence not only IAEA's basic safety standards (safety series 9) ( 2), but also the IAEA regulations for the safe transport of radioactive material ( 3) and its supporting documents ( 4-6). IAEA experts are currently engaged in the revision of the transport regulations. This revision process led to the publication of the revised transport regulations of 1966. The transport regulations are developed to ensure safety during movement of radioactive materials, and to provide reasonable assurance that the transport activities comply with the basic safety standards for radiation protection

  4. Safeguards Automated Facility Evaluation (SAFE) methodology

    International Nuclear Information System (INIS)

    Chapman, L.D.; Grady, L.M.; Bennett, H.A.; Sasser, D.W.; Engi, D.

    1978-01-01

    The SAFE procedure is an efficient method of evaluating the physical protection system of a nuclear facility. Since the algorithms used in SAFE for path generation and evaluation are analytical, many paths can be evaluated with a modest investment in computer time. SAFE is easy to use because the information required is well-defined and the interactive nature of this procedure lends itself to straightforward operation. The modular approach that has been taken allows other functionally equivalent modules to be substituted as they become available. The SAFE procedure has broad applications in the nuclear facility safeguards field as well as in the security field in general. Any fixed facility containing valuable materials or components to be protected from theft or sabotage could be analyzed using this same automated evaluation technique

  5. Outcomes of laparoscopic removal of the Essure sterilization device for pelvic pain: a case series.

    Science.gov (United States)

    Casey, James; Aguirre, Francisco; Yunker, Amanda

    2016-08-01

    The following presents a case series of 29 referral patients who underwent laparoscopic Essure removal for the indication of suspected Essure-related pelvic pain and to describe patient characteristics, intraoperative findings and postoperative pain outcomes. Laparoscopic removal for Essure-associated pelvic pain is a safe and effective treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Comparing the level of dexterity offered by latex and nitrile SafeSkin gloves.

    Science.gov (United States)

    Sawyer, Jo; Bennett, Allan

    2006-04-01

    An increase in the occurrence of latex allergy has been concurrent with the increasing use of latex gloves by laboratory and healthcare workers. In recent years nitrile gloves have been used to replace latex gloves to prevent latex allergy. Nitrile gloves offer a comparable level of protection against chemical and biological agents and are more puncture resistant. However, if manual dexterity is compromised by nitrile gloves to a greater degree than latex then this may increase the risk of sharps injuries. The Purdue pegboard test, which measures both gross and fine finger dexterity, was used to test the dexterity levels of two glove types used at HPA CEPR; Kimberly-Clark SafeSkin nitrile and latex laboratory gloves. There was a statistically significant 8.6% increase in fine finger dexterity provided by latex compared with nitrile SafeSkin laboratory gloves but no difference in gross dexterity between the glove types. There was no significant relationship between glove dexterity and age or gender. The selection of glove size was influenced by the digit length of participants. Moreover, those with longer, thinner fingers appeared to have an advantage when using nitrile SafeSkin gloves. The level of dexterity provided by latex and nitrile SafeSkin gloves for tasks on a gross dexterity level are comparable and health workers will benefit from the non-allergenic properties of nitrile. For tasks requiring fine finger dexterity nitrile SafeSkin gloves may impede dexterity. Despite this, the degree of restriction appears to have a negligible impact on safety in this study when compared with the risk of latex sensitization and subsequent allergy. In addition to glove material, working practices must also take into account glove size, fit, grip and thickness, as these factors can all influence dexterity.

  7. Astute and safe use of topical ocular corticosteroids in general practice

    African Journals Online (AJOL)

    Astute and safe use of topical ocular corticosteroids in general practice: ... is often contact-lens associated) and fungal keratitis. ... for 1 week in acute follicular conjunctivitis presumed to be ... Steroidal anti-inflammatory drugs. In: Rhee DJ. Ophthalmic Drug Guide. London: ... Cataract – by performing a red reflex test. • Herpes ...

  8. Breastfeeding FAQs: Safely Storing Breast Milk

    Science.gov (United States)

    ... Search English Español Breastfeeding FAQs: Safely Storing Breast Milk KidsHealth / For Parents / Breastfeeding FAQs: Safely Storing Breast ... may have. How do I store my breast milk? You can freeze and/or refrigerate your pumped ( ...

  9. Curiosity's Autonomous Surface Safing Behavior Design

    Science.gov (United States)

    Neilson, Tracy A.; Manning, Robert M.

    2013-01-01

    The safing routines on all robotic deep-space vehicles are designed to put the vehicle in a power and thermally safe configuration, enabling communication with the mission operators on Earth. Achieving this goal is made a little more difficult on Curiosity because the power requirements for the core avionics and the telecommunication equipment exceed the capability of the single power source, the Multi-Mission Radioisotope Thermoelectric Generator. This drove the system design to create an operational mode, called "sleep mode", where the vehicle turns off most of the loads in order to charge the two Li-ion batteries. The system must keep the vehicle safe from over-heat and under-heat conditions, battery cell failures, under-voltage conditions, and clock failures, both while the computer is running and while the system is sleeping. The other goal of a safing routine is to communicate. On most spacecraft, this simply involves turning on the receiver and transmitter continuously. For Curiosity, Earth is above the horizon only a part of the day for direct communication to the Earth, and the orbiter overpass opportunities only occur a few times a day. The design must robustly place the Rover in a communicable condition at the correct time. This paper discusses Curiosity's autonomous safing behavior and describes how the vehicle remains power and thermally safe while sleeping, as well as a description of how the Rover communicates with the orbiters and Earth at specific times.

  10. Concept of an inherently-safe high temperature gas-cooled reactor

    International Nuclear Information System (INIS)

    Ohashi, Hirofumi; Sato, Hiroyuki; Tachibana, Yukio; Kunitomi, Kazuhiko; Ogawa, Masuro

    2012-01-01

    As the challenge to ensure no harmful release of radioactive materials at the accidents by deterministic approach instead to satisfy acceptance criteria or safety goal for risk by probabilistic approach, new concept of advanced reactor, an inherently-safe high temperature gas-cooled reactor, is proposed based on the experience of the operation of the actual High Temperature Gas-cooled Reactor (HTGR) in Japan, High Temperature Engineering Test Reactor (HTTR), and the design of the commercial plant (GTHTR300), utilizing the inherent safety features of the HTGR (i.e., safety features based on physical phenomena). The safety design philosophy of the inherently-safe HTGR for the safety analysis of the radiological consequences is determined as the confinement of radioactive materials is assured by only inherent safety features without engineered safety features, AC power or prompt actions by plant personnel if the design extension conditions occur. Inherent safety features to prevent the loss or degradation of the confinement function are identified. It is proposed not to apply the probabilistic approach for the evaluation of the radiological consequences of the accidents in the safety analysis because no inherent safety features fail for the mitigation of the consequences of the accidents. Consequently, there are no event sequences to harmful release of radioactive materials if the design extension conditions occur in the inherently-safe HTGR concept. The concept and future R and D items for the inherently-safe HTGR are described in this paper.

  11. Removing Hair Safely

    Science.gov (United States)

    ... For Consumers Home For Consumers Consumer Updates Removing Hair Safely Share Tweet Linkedin Pin it More sharing ... related to common methods of hair removal. Laser Hair Removal In this method, a laser destroys hair ...

  12. Costationarity of Locally Stationary Time Series Using costat

    OpenAIRE

    Cardinali, Alessandro; Nason, Guy P.

    2013-01-01

    This article describes the R package costat. This package enables a user to (i) perform a test for time series stationarity; (ii) compute and plot time-localized autocovariances, and (iii) to determine and explore any costationary relationship between two locally stationary time series. Two locally stationary time series are said to be costationary if there exists two time-varying combination functions such that the linear combination of the two series with the functions produces another time...

  13. Safe and secure South Africa. Vehicle landmine protection validation testing

    CSIR Research Space (South Africa)

    Reinecke, JD

    2008-11-01

    Full Text Available The objective of this paper is to provide an overview of vehicle landmine protection validation testing in South Africa. A short history of validation test standards is given, followed by a summary of current open test standards in general use...

  14. Power-Cooling-Mismatch Test Series. Test PCM-2: postirradiation examination

    International Nuclear Information System (INIS)

    Seiffert, S.L.

    1977-03-01

    The report describes the results of the postirradiation examination of four 0.91-m long pressurized water reactor (PWR) type, UO 2 -fueled zircaloy-clad fuel rods tested in an in-pile experimental investigation of pre- and post-departure from nucleate boiling (DNB) behavior of previously unirradiated fuel rods. None of the four fuel rods tested failed during testing or during reactor shut down. Visual and metallographic examination of the individual fuel rods indicated that the length of the high temperature zone of film boiling varied from rod to rod. Two of the four fuel rods showed evidence of damage by film boiling, characterized by oxide spalling and cladding collapse. Metallographic examination of these fuel rods showed internal cladding oxidation resulting from fuel-cladding reaction. Cladding embrittlement by oxidation is evaluated. A comparison of the cladding surface temperatures estimated metallographically for the separate fuel rods with cladding surface temperatures measured during testing and calculated from the Fuel Rod Analysis Program-Transient (FRAP-T) computer code is included

  15. White gauze test: a novel technique in preventing post-hepatectomy bile leak.

    Science.gov (United States)

    Yugasaravanan, K; Affirul, C A; Zamri, Z; Azlanudin, A; Bong, J J

    Post-hepatectomy bile leak may lead to undesired morbidity. Multiple methods have been employed to identify this leak but can be inconclusive and taxing. This novel white gauze test is a simple and reliable method. This is a prospective study performed from January 2010 until March 2011. All open hepatic resection were included. Dry white gauze is compressed onto the transected surface and observed for bile staining. The leaking duct is repaired immediately upon detection. The process is repeated until negative. Drain was removed on postoperative day-5. Post-operative bile leak is defined as: 1. Bilirubin concentration of the drain fluid is 3 times or higher than serum; 2. Presence of intra-abdominal bile collection on imaging and upon drainage; 3. Bile leak demonstrated on postoperative cholangiography. 42 patients were recruited. Seven (16.7%) patients were cirrhotic with Child-Pugh A. White gauze test were positive for intra-operative bile leaks in 29 patients (70%), which were primarily repaired. As a result, there was no postoperative bile leak in this series. One mortality was detected in this series due to postoperative pancreatic fistula and multi organ failure. The White Gauze Test is a useful method for the prevention of bile leakage after hepatic resection. It is safe, quick and cheap.

  16. ECONOMETRIC APPROACH OF HETEROSKEDASTICITY ON FINANCIAL TIME SERIES IN A GENERAL FRAMEWORK

    Directory of Open Access Journals (Sweden)

    FELICIA RAMONA BIRĂU

    2012-12-01

    Full Text Available The aim of this paper is to provide an overview of the diagnostic tests for detecting heteroskedasticity on financial time series. In financial econometrics, heteroskedasticity is generally associated with cross sectional data but can also be identified modeling time series data. The presence of heteroscedasticity in financial time series can be caused by certain specific factors, like a model misspecification, inadequate data transformation or as a result of certain outliers. Heteroskedasticity arise when the homoskedasticity assumption is violated. Testing for the presence of heteroskedasticity in financial time is performed by applying diagnostic test, such as : Breusch-Pagan LM test, White’s test, Glesjer LM test, Harvey-Godfrey LM test, Park LM test and Goldfeld-Quand test.

  17. Safe Reentry for False Aneurysm Operations in High-Risk Patients.

    Science.gov (United States)

    Martinelli, Gian Luca; Cotroneo, Attilio; Caimmi, Philippe Primo; Musica, Gabriele; Barillà, David; Stelian, Edmond; Romano, Angelo; Novelli, Eugenio; Renzi, Luca; Diena, Marco

    2017-06-01

    In the absence of a standardized safe surgical reentry strategy for high-risk patients with large or anterior postoperative aortic false aneurysm (PAFA), we aimed to describe an effective and safe approach for such patients. We prospectively analyzed patients treated for PAFA between 2006 and 2015. According to the preoperative computed tomography scan examination, patients were divided into two groups according to the anatomy and extension of PAFA: in group A, high-risk PAFA (diameter ≥3 cm) developed in the anterior mediastinum; in group B, low-risk PAFA (diameter <3 cm) was situated posteriorly. For group A, a safe surgical strategy, including continuous cerebral, visceral, and coronary perfusion was adopted before resternotomy; group B patients underwent conventional surgery. We treated 27 patients (safe reentry, n = 13; standard approach, n = 14). Mean age was 60 years (range, 29 to 80); 17 patients were male. Mean interval between the first operation and the last procedure was 4.3 years. Overall 30-day mortality rate was 7.4% (1 patient in each group). No aorta-related mortality was observed at 1 and 5 years in either group. The Kaplan-Meier overall survival estimates at 1 and 5 years were, respectively, 92.3% ± 7.4% and 73.4% ± 13.4% in group A, and 92.9% ± 6.9% and 72.2% ± 13.9% in group B (log rank test, p = 0.830). Freedom from reoperation for recurrent aortic disease was 100% at 1 year and 88% at 5 years. The safe reentry technique with continuous cerebral, visceral, and coronary perfusion for high-risk patients resulted in early and midterm outcomes similar to those observed for low-risk patients undergoing conventional surgery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Developing Safe Schools Partnerships with Law Enforcement

    Science.gov (United States)

    Rosiak, John

    2009-01-01

    Safe schools are the concern of communities throughout the world. If a school is safe, and if children feel safe, students "are better able to learn. But what are the steps to make" this happen? First, it is important to understand the problem: What are the threats to school safety? These include crime-related behaviors that find their way to…

  19. Stochastic time series analysis of hydrology data for water resources

    Science.gov (United States)

    Sathish, S.; Khadar Babu, S. K.

    2017-11-01

    The prediction to current publication of stochastic time series analysis in hydrology and seasonal stage. The different statistical tests for predicting the hydrology time series on Thomas-Fiering model. The hydrology time series of flood flow have accept a great deal of consideration worldwide. The concentration of stochastic process areas of time series analysis method are expanding with develop concerns about seasonal periods and global warming. The recent trend by the researchers for testing seasonal periods in the hydrologic flowseries using stochastic process on Thomas-Fiering model. The present article proposed to predict the seasonal periods in hydrology using Thomas-Fiering model.

  20. Test results of sodium-water reaction testing in near prototypical LMR steam generator

    International Nuclear Information System (INIS)

    Boardman, C.E.; Hui, M.; Neely, H.H.

    1990-01-01

    An extensive test program has been performed in the United States to investigate the effects of large sodium-water reaction events in LMFBR steam generators. Tests were conducted in the Large Leak Test Rig (LLTR) located at the Energy Technology Engineering Center (ETEC). The program was divided into two phases, Series I and Series II, for the purpose of satisfying near-term and long-term needs. Series II was further subdivided into large and intermediate leak tests. This paper will emphasize the Series II intermediate leak tests and resulting conclusions for steam generator design and operation. 11 figs, 2 tabs

  1. Towards Safe Robotic Surgical Systems

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Wisniewski, Rafael

    2015-01-01

    a controller for motion compensation in beating-heart surgery, and prove that it is safe, i.e., the surgical tool is kept within an allowable distance and orientation of the heart. We solve the problem by simultaneously finding a control law and a barrier function. The motion compensation system is simulated...... from several initial conditions to demonstrate that the designed control system is safe for every admissible initial condition....

  2. Safe use of ionizing radiations

    Energy Technology Data Exchange (ETDEWEB)

    1973-01-01

    Based on the ''Code of Practice for the protection of persons against ionizing radiations arising from medical and dental use'' (CIS 74-423), this handbook shows how hospital staff can avoid exposing themselves and others to these hazards. It is designed particularly for junior and student nurses. Contents: ionizing radiations, their types and characteristics; their uses and dangers; basic principles in their safe use; safe use in practice; explanation of terms.

  3. Staying Safe in the Water

    Centers for Disease Control (CDC) Podcasts

    2008-05-15

    In this podcast, Dr. Julie Gilchrist, a pediatrician and medical epidemiologist from CDC’s Injury Center, talks about staying safe in the water. Tips are for all audiences, with a focus on preventing drownings and keeping children safe in and around the pool, lake, or ocean.  Created: 5/15/2008 by National Center for Injury Prevention and Control (NCIPC).   Date Released: 5/19/2008.

  4. Reliable JavaScript how to code safely in the world's most dangerous language

    CERN Document Server

    Spencer, Lawrence

    2015-01-01

    Create more robust applications with a test-first approach to JavaScript Reliable JavaScript, How to Code Safely in the World's Most Dangerous Language demonstrates how to create test-driven development for large-scale JavaScript applications that will stand the test of time and stay accurate through long-term use and maintenance. Taking a test-first approach to software architecture, this book walks you through several patterns and practices and explains what they are supposed to do by having you write unit tests. Write the code to pass the unit tests, so you not only develop your technique

  5. Regulations for the safe transport of radioactive material. 1985 ed. Supplement 1988

    International Nuclear Information System (INIS)

    1988-01-01

    A major revision of the Agency's Regulations for the Safe Transport of Radioactive Material, Safety Series No. 6, was undertaken during a period of several years, culminating in the publication of the 1985 Edition. In order to consider minor problems in the new edition, the Agency convened a panel of experts in January 1986. This panel recommended some amendments which were subsequently published as Supplement 1986 to the Regulations. A further review panel meeting took place in June 1987. The amendments which were recommended for early adoption were themselves divided into two kinds. The first of these are designated as minor changes. The second kind of amendment recommended for early adoption comprises actual changes to regulatory provisions. Several changes of this second type were recommended by the panel and are included in this Supplement. The Supplement also contains the amended texts of the supporting documents, Safety Series Nos 7, 37 and 80, which are necessary to correct minor errors as well as to provide complementary information for the changes introduced to the Regulations themselves. In addition, the Supplement embodies the contents of Supplement 1986, which is consequently superseded.

  6. Final Report - Assessment of Testing Options for the NTR at the INL

    Energy Technology Data Exchange (ETDEWEB)

    Howe, Steven D; McLing, Travis L; McCurry, Michael; Plummer, Mitchell A

    2013-02-01

    One of the main technologies that can be developed to dramatically enhance the human exploration of space is the nuclear thermal rocket (NTR). Several studies over the past thirty years have shown that the NTR can reduce the cost of a lunar outpost, reduce the risk of a human mission to Mars, enable fast transits for most missions throughout the solar system, and reduce the cost and time for robotic probes to deep space. Three separate committees of the National Research Council of the National Academy of Sciences have recommended that NASA develop the NTR. One of the primary issues in development of the NTR is the ability to verify a flight ready unit. Three main methods can be used to validate safe operation of a NTR: 1) Full power, full duration test in an above ground facility that scrubs the rocket exhaust clean of any fission products; 2) Full power , full duration test using the Subsurface Active Filtering of Exhaust (SAFE) technique to capture the exhaust in subsurface strata; 3) Test of the reactor fuel at temperature and power density in a driver reactor with subsequent first test of the fully integrated NTR in space. The first method, the above ground facility, has been studied in the past. The second method, SAFE, has been examined for application at the Nevada Test Site. The third method relies on the fact that the Nuclear Furnace series of tests in 1971 showed that the radioactive exhaust coming from graphite based fuel for the NTR could be completely scrubbed of fission products and the clean hydrogen flared into the atmosphere. Under funding from the MSFC, the Center for Space Nuclear Research (CSNR) at the Idaho National laboratory (INL) has completed a reexamination of Methods 2 and 3 for implementation at the INL site. In short, the effort performed the following: 1) Assess the geology of the INL site and determine a location suitable SAFE testing; 2) Perform calculations of gas transport throughout the geology; 3) Produce a cost estimate of a

  7. Integral Battery Power Limiting Circuit for Intrinsically Safe Applications

    Science.gov (United States)

    Burns, Bradley M.; Blalock, Norman N.

    2010-01-01

    A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal oxide semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels. The comparator detects this drop and opens the switch before the current in the inductor has a chance to respond. This circuit protects both the current and voltage from exceeding safe levels. Typically, this type of protection is accomplished by a fuse or a circuit breaker, but in order for a fuse or a circuit breaker to blow or trip, the current must exceed the safe levels momentarily, which may be just enough time to ignite anything in a hazardous environment. To prevent this from happening, a fuse is typically current-limited by the addition of the resistor to keep the current within safe levels while the fuse reacts. The use of a resistor is acceptable for non-battery applications where the wasted energy and voltage drop across the resistor can be tolerated. The use of the switch and inductor minimizes the wasted energy. For example, a circuit runs from a 3.6-V battery that must be current-limited to 200 mA. If the circuit normally draws 10 mA, then an 18-ohm resistor would drop 180 mV during normal operation, while a typical switch (0.02 ohm) and inductor (0.97 ohm) would only drop 9.9 mV. From a power standpoint, the current-limiting resistor protection circuit wastes about 18 times more power than the

  8. Safe operating envelope

    Energy Technology Data Exchange (ETDEWEB)

    Oliva, N [Ontario Hydro, Toronto, ON (Canada)

    1997-12-01

    Safe Operating Envelope is described representing: The outer bound of plant conditions within which day-to-day plant operation must be maintained in order to comply with regulatory requirements, associated safety design criteria and corporate nuclear safety goals. Figs.

  9. Safe operating envelope

    International Nuclear Information System (INIS)

    Oliva, N.

    1997-01-01

    Safe Operating Envelope is described representing: The outer bound of plant conditions within which day-to-day plant operation must be maintained in order to comply with regulatory requirements, associated safety design criteria and corporate nuclear safety goals. Figs

  10. Baseline series fragrance markers fail to predict contact allergy.

    Science.gov (United States)

    Mann, Jack; McFadden, John P; White, Jonathan M L; White, Ian R; Banerjee, Piu

    2014-05-01

    Negative patch test results with fragrance allergy markers in the European baseline series do not always predict a negative reaction to individual fragrance substances. To determine the frequencies of positive test reactions to the 26 fragrance substances for which labelling is mandatory in the EU, and how effectively reactions to fragrance markers in the baseline series predict positive reactions to the fragrance substances that are labelled. The records of 1951 eczema patients, routinely tested with the labelled fragrance substances and with an extended European baseline series in 2011 and 2012, were retrospectively reviewed. Two hundred and eighty-one (14.4%) (71.2% females) reacted to one or more allergens from the labelled-fragrance substance series and/or a fragrance marker from the European baseline series. The allergens that were positive with the greatest frequencies were cinnamyl alcohol (48; 2.46%), Evernia furfuracea (44; 2.26%), and isoeugenol (40; 2.05%). Of the 203 patients who reacted to any of the 26 fragrances in the labelled-fragrance substance series, only 117 (57.6%) also reacted to a fragrance marker in the baseline series. One hundred and seven (52.7%) reacted to either fragrance mix I or fragrance mix II, 28 (13.8%) reacted to Myroxylon pereirae, and 13 (6.4%) reacted to hydroxyisohexyl 3-cyclohexene carboxaldehyde. These findings confirm that the standard fragrance markers fail to identify patients with contact allergies to the 26 fragrances. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Case Series Investigations in Cognitive Neuropsychology

    Science.gov (United States)

    Schwartz, Myrna F.; Dell, Gary S.

    2011-01-01

    Case series methodology involves the systematic assessment of a sample of related patients, with the goal of understanding how and why they differ from one another. This method has become increasingly important in cognitive neuropsychology, which has long been identified with single-subject research. We review case series studies dealing with impaired semantic memory, reading, and language production, and draw attention to the affinity of this methodology for testing theories that are expressed as computational models and for addressing questions about neuroanatomy. It is concluded that case series methods usefully complement single-subject techniques. PMID:21714756

  12. Formulating and testing a method for perturbing precipitation time series to reflect anticipated climatic changes

    DEFF Research Database (Denmark)

    Sørup, Hjalte Jomo Danielsen; Georgiadis, Stylianos; Gregersen, Ida Bülow

    2017-01-01

    Urban water infrastructure has very long planning horizons, and planning is thus very dependent on reliable estimates of the impacts of climate change. Many urban water systems are designed using time series with a high temporal resolution. To assess the impact of climate change on these systems......, similarly high-resolution precipitation time series for future climate are necessary. Climate models cannot at their current resolutions provide these time series at the relevant scales. Known methods for stochastic downscaling of climate change to urban hydrological scales have known shortcomings...... in constructing realistic climate-changed precipitation time series at the sub-hourly scale. In the present study we present a deterministic methodology to perturb historical precipitation time series at the minute scale to reflect non-linear expectations to climate change. The methodology shows good skill...

  13. Assessing error sources for Landsat time series analysis for tropical test sites in Viet Nam and Ethiopia

    Science.gov (United States)

    Schultz, Michael; Verbesselt, Jan; Herold, Martin; Avitabile, Valerio

    2013-10-01

    Researchers who use remotely sensed data can spend half of their total effort analysing prior data. If this data preprocessing does not match the application, this time spent on data analysis can increase considerably and can lead to inaccuracies. Despite the existence of a number of methods for pre-processing Landsat time series, each method has shortcomings, particularly for mapping forest changes under varying illumination, data availability and atmospheric conditions. Based on the requirements of mapping forest changes as defined by the United Nations (UN) Reducing Emissions from Forest Degradation and Deforestation (REDD) program, the accurate reporting of the spatio-temporal properties of these changes is necessary. We compared the impact of three fundamentally different radiometric preprocessing techniques Moderate Resolution Atmospheric TRANsmission (MODTRAN), Second Simulation of a Satellite Signal in the Solar Spectrum (6S) and simple Dark Object Subtraction (DOS) on mapping forest changes using Landsat time series data. A modification of Breaks For Additive Season and Trend (BFAST) monitor was used to jointly map the spatial and temporal agreement of forest changes at test sites in Ethiopia and Viet Nam. The suitability of the pre-processing methods for the occurring forest change drivers was assessed using recently captured Ground Truth and high resolution data (1000 points). A method for creating robust generic forest maps used for the sampling design is presented. An assessment of error sources has been performed identifying haze as a major source for time series analysis commission error.

  14. Water Under Fire: A Seven Part Video Series on Canada's Water

    Science.gov (United States)

    Mrazek, R.; Byrne, J.; Rabe, N.; Gallant, G.

    2003-12-01

    Canada's water is under escalating pressure from a host of threats. Increasingly, our water is being tainted, misused and over allocated. Experts have identified a multitude of threats to water quantity and quality. Among them, climate change impacts on water supply, and the effects of pesticides, pathogens, industrial waste, urban runoff, and rising demands. These and other threats are the roots to a serious shortage of high quality, safe water sources. In the 1990s, waterborne diseases have re-emerged as one of the primary health issues on a national and global scale. This seven-part video series brings science voices together and provides a nationwide context. The first six programs in the series explore regional concerns: Rocky Mountains, Prairie Waters, Northern Waters, Great Lakes Basin, St. Lawrence and Atlantic Canada. The final program covers the national and international perspectives.

  15. Safe handling of renewable fuels and fuel mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Wilen, C; Rautalin, A [VTT Energy, Espoo (Finland)

    1997-12-01

    VTT Energy has for several years carried out co-operation with many European research institutes on contractional basis on safety issues of fuels handling. A two-year co-operational project between VTT Energy and these research institutes was started in EU`s JOULE 3 programme in 1996, the total budget of which is 6.9 million FIM. Dust explosion testing method for `difficult` fuels, and for tests at elevated pressures and temperatures, will be developed in the task `Safe handling of renewable fuels and fuel mixtures`. Self- ignition and dust-explosion characteristics will be generated for wood and agro-biomass based biomasses and for the mixtures of them and coal. Inertization requirements will be studied, and the quenching method, combined with partial inertization, will be tested in 1.0 m{sup 3} test equipment. The ignition properties of the fuels under normal and elevated pressures will be characterised with thermobalances. The self-ignition tests with wood and forest residue dusts at 25 bar pressure have been carried out as scheduled. In addition to this, several fuels have undergone thermobalance tests, sieve analyses and microscopic studies for the characterisation of the fuels

  16. Clinical Inquiry: Is megestrol acetate safe and effective for malnourished nursing home residents?

    Science.gov (United States)

    Wen, Frances K; Millar, James; Oberst-Walsh, Linda; Nashelsky, Joan

    2018-02-01

    No. Megestrol acetate (MA) is neither safe nor effective for stimulating appetite in malnourished nursing home residents. It increases the risk of deep vein thrombosis (strength of recommendation [SOR]: C, 2 retrospective chart reviews), but isn't associated with other new or worsening events or disorders (SOR: B, single randomized controlled trial [RCT]). Over a 25-week period, MA wasn't associated with increased mortality (SOR: B, single RCT). After 44 months, however, MA-treated patients showed decreased median survival (SOR: B, single case-control study). Consistent, meaningful weight gain was not observed with MA treatment (SOR: B, single case-control study, single RCT, 2 retrospective chart reviews, single prospective case-series).

  17. Feeling safe during an inpatient hospitalization: a concept analysis.

    Science.gov (United States)

    Mollon, Deene

    2014-08-01

    This paper aims to explore the critical attributes of the concept feeling safe. The safe delivery of care is a high priority; however; it is not really known what it means to the patient to 'feel safe' during an inpatient hospitalization. This analysis explores the topic of safety from the patient's perspective. Concept analysis. The data bases of CINAHL, Medline, PsychInfo and Google Scholar for the years 1995-2012 were searched using the terms safe and feeling safe. The eight-step concept analysis method of Walker and Avant was used to analyse the concept of feeling safe. Uses and defining attributes, as well as identified antecedents, consequences and empirical referents, are presented. Case examples are provided to assist in the understanding of defining attributes. Feeling safe is defined as an emotional state where perceptions of care contribute to a sense of security and freedom from harm. Four attributes were identified: trust, cared for, presence and knowledge. Relationship, environment and suffering are the antecedents of feeling safe, while control, hope and relaxed or calm are the consequences. Empirical referents and early development of a theory of feeling safe are explored. This analysis begins the work of synthesizing qualitative research already completed around the concept of feeling safe by defining the key attributes of the concept. Support for the importance of developing patient-centred models of care and creating positive environments where patients receive high-quality care and feel safe is provided. © 2014 John Wiley & Sons Ltd.

  18. Creating Safe Spaces for Music Learning

    Science.gov (United States)

    Hendricks, Karin S.; Smith, Tawnya D.; Stanuch, Jennifer

    2014-01-01

    This article offers a practical model for fostering emotionally safe learning environments that instill in music students a positive sense of self-belief, freedom, and purpose. The authors examine the implications for music educators of creating effective learning environments and present recommendations for creating a safe space for learning,…

  19. Device Design and Test of Fatigue Behaviour of Expansion Anchor Subjected to Tensile Loads

    Directory of Open Access Journals (Sweden)

    Zhang Jinfeng

    2016-01-01

    Full Text Available In order to study on the fatigue behaviour of expansion anchor (M16, grade 8.8 for overhead contact system in electrification railways, a set of safe, practical loading device is designed and a fatigue test campaign was carried out at structural laboratory of China Academy of Building Research on expansion anchor embedded in concrete block. The mobile frame of the loading device was designed well by finite-element simulation. According to some fatigue performance test of expansion anchor with different size and form, the device have been assessed experimentally its dependability. The results were found that no fatigue damage phenomenon occurred in all specimens after 2×106 cycles tensile fatigue test in this specific series. It shows that in the condition of medium level or slightly lower maximum stress limit and nominal stress range, expansion bolt has good fatigue resistance. The biggest relative displacement and the residual relative displacement after test (Δδ = δ2-δ1 was also strongly lower than the symbol of the fatigue test failure index of this specific series (0.5mm in the high cycle fatigue regime. The ultimate tension failures mode after fatigue tests in all tested samples take place in the concrete anchorage zone. The reduction range of the ultimate tensile strength properties of the anchorage system was not obvious, and the concrete was seen to be the weakest link of the system.

  20. Keeping Food Safe

    Centers for Disease Control (CDC) Podcasts

    2009-05-27

    This CDC Kidtastics podcast discusses things kids and parents can do to help prevent illness by keeping food safe.  Created: 5/27/2009 by National Center for Zoonotic, Vector-Borne, and Enteric Diseases (NCZVED).   Date Released: 5/27/2009.

  1. Fast reactor safety testing in Transient Reactor Test (TREAT) in the 1980s

    International Nuclear Information System (INIS)

    Wright, A.E.; Dutt, D.S.; Harrison, L.J.

    1990-01-01

    Several series of fast reactor safety tests were performed in TREAT during the 1980s. These focused on the transient behavior of full-length oxide fuels (US reference, UK reference, and US advanced design) and on modern metallic fuels. Most of the tests addressed fuel behavior under transient overpower or loss-of-flow conditions. The test series were the PFR/TREAT tests; the RFT, TS, CDT, and RX series on oxide fuels; and the M series on metallic fuels. These are described in terms of their principal results and relevance to analyses and safety evaluation. 4 refs., 3 tabs

  2. Summary of advanced LMR [Liquid Metal Reactor] evaluations: PRISM [Power Reactor Inherently Safe Module] and SAFR [Sodium Advanced Fast Reactor

    International Nuclear Information System (INIS)

    Van Tuyle, G.J.; Slovik, G.C.; Chan, B.C.; Kennett, R.J.; Cheng, H.S.; Kroeger, P.G.

    1989-10-01

    In support of the US Nuclear Regulatory Commission (NRC), Brookhaven National Laboratory (BNL) has performed independent analyses of two advanced Liquid Metal Reactor (LMR) concepts. The designs, sponsored by the US Department of Energy (DOE), the Power Reactor Inherently Safe Module (PRISM) [Berglund, 1987] and the Sodium Advanced Fast Reactor (SAFR) [Baumeister, 1987], were developed primarily by General Electric (GE) and Rockwell International (RI), respectively. Technical support was provided to DOE, RI, and GE, by the Argonne National Laboratory (ANL), particularly with respect to the characteristics of the metal fuels. There are several examples in both PRISM and SAFR where inherent or passive systems provide for a safe response to off-normal conditions. This is in contrast to the engineered safety systems utilized on current US Light Water Reactor (LWR) designs. One important design inherency in the LMRs is the ''inherent shutdown'', which refers to the tendency of the reactor to transition to a much lower power level whenever temperatures rise significantly. This type of behavior was demonstrated in a series of unscrammed tests at EBR-II [NED, 1986]. The second key design feature is the passive air cooling of the vessel to remove decay heat. These systems, designated RVACS in PRISM and RACS in SAFR, always operate and are believed to be able to prevent core damage in the event that no other means of heat removal is available. 27 refs., 78 figs., 3 tabs

  3. Pre-series and testing route for the serial fabrication of W7-X target elements

    International Nuclear Information System (INIS)

    Boscary, J.; Greuner, H.; Friedrich, T.; Traxler, H.; Mendelevitch, B.; Boeswirth, B.; Schlosser, J.; Smirnow, M.; Stadler, R.

    2009-01-01

    The fabrication of the actively cooled high-heat flux divertor of the WENDELSTEIN 7-X stellarator (W7-X) requires the delivery of 890 target elements, which are designed to withstand a stationary heat flux of 10 MW/m 2 . The organization of the manufacturing and testing route for the serial fabrication is the result of the pre-series activities. Flat CFC Sepcarb NB31 tiles are bonded to CuCrZr copper alloy cooling structure in consecutive steps. A copper layer is active metal cast to CFC tiles, and then an OF-copper layer is added by hot isostatic pressing to produce bi-layer tiles. These tiles are bonded by electron beam welding onto the cooling structure, which was manufactured independently. The introduction of the bi-layer technology proved to be a significant improvement of the bond reliability under thermal cycling loading. This result is also the consequence of the improved bond inspections throughout the manufacturing route performed in the ARGUS pulsed thermography facility of PLANSEE. The repairing process by electron beam welding of the bonding was also qualified. The extended pre-series activities related to the qualification of fabrication processes with the relevant non-destructive examinations aim to minimize the risks for the serial manufacturing and to guarantee the steady-state operation of the W7-X divertor.

  4. Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests

    Science.gov (United States)

    Passerini, S.; Coustier, F.; Owens, B. B.

    Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.

  5. Studies on time series applications in environmental sciences

    CERN Document Server

    Bărbulescu, Alina

    2016-01-01

    Time series analysis and modelling represent a large study field, implying the approach from the perspective of the time and frequency, with applications in different domains. Modelling hydro-meteorological time series is difficult due to the characteristics of these series, as long range dependence, spatial dependence, the correlation with other series. Continuous spatial data plays an important role in planning, risk assessment and decision making in environmental management. In this context, in this book we present various statistical tests and modelling techniques used for time series analysis, as well as applications to hydro-meteorological series from Dobrogea, a region situated in the south-eastern part of Romania, less studied till now. Part of the results are accompanied by their R code. .

  6. Wavelet transform approach for fitting financial time series data

    Science.gov (United States)

    Ahmed, Amel Abdoullah; Ismail, Mohd Tahir

    2015-10-01

    This study investigates a newly developed technique; a combined wavelet filtering and VEC model, to study the dynamic relationship among financial time series. Wavelet filter has been used to annihilate noise data in daily data set of NASDAQ stock market of US, and three stock markets of Middle East and North Africa (MENA) region, namely, Egypt, Jordan, and Istanbul. The data covered is from 6/29/2001 to 5/5/2009. After that, the returns of generated series by wavelet filter and original series are analyzed by cointegration test and VEC model. The results show that the cointegration test affirms the existence of cointegration between the studied series, and there is a long-term relationship between the US, stock markets and MENA stock markets. A comparison between the proposed model and traditional model demonstrates that, the proposed model (DWT with VEC model) outperforms traditional model (VEC model) to fit the financial stock markets series well, and shows real information about these relationships among the stock markets.

  7. Safe injection practice among health care workers, Gharbiya, Egypt.

    Science.gov (United States)

    Ismail, Nanees A; Aboul Ftouh, Aisha M; El Shoubary, Waleed H

    2005-01-01

    A cross-sectional study was conducted in 25 health care facilities in Gharbiya governorate to assess safe injection practices among health care workers (HCWs). Two questionnaires, one to collect information about administrative issues related to safe injection and the other to collect data about giving injections, exposure to needle stick injuries, hepatitis B vaccination status and safe injection training. Practices of injections were observed using a standardized checklist. The study revealed that there was lack of both national and local infection control policies and lack of most of the supplies needed for safe injection practices. Many safe practices were infrequent as proper needle manipulation before disposal (41%), safe needle disposal (47.5%), reuse of used syringe & needle (13.2%) and safe syringe disposal (0%). Exposure to needle stick injuries were common among the interviewed HCWs (66.2%) and hand washing was the common post exposure prophylaxis measure (63.4%). Only 11.3% of HCWs had full course hepatitis B vaccination. Infection control -including safe injections- training programs should be afforded to all HCWs.

  8. Monitoring contact sensitization to p-phenylenediamine (PPD) by patch testing with PPD 0.3% in petrolatum.

    Science.gov (United States)

    Geier, Johannes; Ballmer-Weber, Barbara K; Dickel, Heinrich; Frosch, Peter J; Bircher, Andreas; Weisshaar, Elke; Hillen, Uwe

    2013-07-01

    Being a contact allergen of general relevance, p-phenylenediamine (PPD) is patch tested in the baseline series. However, PPD 1% in petrolatum may actively sensitize. Patch testing with PPD at 0.35% pet. proved to be safe, as far as active sensitization is concerned. To determine whether PPD 0.3% pet. reliably detects PPD sensitization. Patch testing with PPD 0.3% pet. and 1% pet. synchronously was performed in consecutive patients in a multicentre study within the Information Network of Departments of Dermatology. Altogether, 2042 patients were patch tested. PPD 1% pet. yielded 6.0% positive reactions (n = 123), and PPD 0.3% pet. yielded 4.7% (n = 95). The synchronous reproducibility of PPD reactions was similar as known from parallel patch tests with identical PPD concentrations. The diagnostic properties of PPD 0.3% pet. expressed as reaction index and positivity ratio were good. Of the 123 patients reacting to PPD 1% pet., 32 (26%) had no positive reaction to PPD 0.3% pet. In 22 of these 32 patients (69%), no clinical relevance could be found. As patch testing with PPD 0.3% pet. is reliable according to our results, we recommend replacing PPD 1% pet. in the baseline series with PPD 0.3% pet. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. SafeNet: a methodology for integrating general-purpose unsafe devices in safe-robot rehabilitation systems.

    Science.gov (United States)

    Vicentini, Federico; Pedrocchi, Nicola; Malosio, Matteo; Molinari Tosatti, Lorenzo

    2014-09-01

    Robot-assisted neurorehabilitation often involves networked systems of sensors ("sensory rooms") and powerful devices in physical interaction with weak users. Safety is unquestionably a primary concern. Some lightweight robot platforms and devices designed on purpose include safety properties using redundant sensors or intrinsic safety design (e.g. compliance and backdrivability, limited exchange of energy). Nonetheless, the entire "sensory room" shall be required to be fail-safe and safely monitored as a system at large. Yet, sensor capabilities and control algorithms used in functional therapies require, in general, frequent updates or re-configurations, making a safety-grade release of such devices hardly sustainable in cost-effectiveness and development time. As such, promising integrated platforms for human-in-the-loop therapies could not find clinical application and manufacturing support because of lacking in the maintenance of global fail-safe properties. Under the general context of cross-machinery safety standards, the paper presents a methodology called SafeNet for helping in extending the safety rate of Human Robot Interaction (HRI) systems using unsafe components, including sensors and controllers. SafeNet considers, in fact, the robotic system as a device at large and applies the principles of functional safety (as in ISO 13489-1) through a set of architectural procedures and implementation rules. The enabled capability of monitoring a network of unsafe devices through redundant computational nodes, allows the usage of any custom sensors and algorithms, usually planned and assembled at therapy planning-time rather than at platform design-time. A case study is presented with an actual implementation of the proposed methodology. A specific architectural solution is applied to an example of robot-assisted upper-limb rehabilitation with online motion tracking. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Hydro-Quebec to complete series compensation protection by 1995

    Energy Technology Data Exchange (ETDEWEB)

    Champagne, L

    1991-09-01

    Hydro-Quebec's 735-kV transmission system is characterized by remote hydroelectric power plants located far north of main load centers, making it difficult to maintain dynamic stability of the system in the case of faults. The utility is planning to install series compensation on its 735-kV network from 1992 to 1995 in order to correct for the reactive impedance of the transmission lines, thereby removing load electrically closer to the points of generation. Series compensation in the form of capacitor banks with overvoltage protection will be installed at line ends and will replace large numbers of conventional electromagnetic or electronic distance relays currently used as line protection equipment. Three Manicouagan-Levis lines and the Micoua-Laurentides line will be center-compensated at 17%. A total of thirty-seven 735-kV lines will be series-compensated at ca 40%. Two separate sets of tests were conducted to select the new series compensation system. Following a market study, eight systems of line protection relays were selected as most likely to operate on a series compensated system. All were performance tested on a transient network analyzer in a simulation involving all components of the 735-kV system with some exceptions. Relays singled out in standard tests were put to a series of more specific tests on the Abitibi-LaVerendrye line, where the largest number of relay malfunctions had been recorded. A current differential relay and a superimposed directional relay were recommended as the two primary protective systems to be installed. Backup protection will be provided by using one of the distance relays with memory polarization. 3 figs.

  11. Implicit attitudes towards risky and safe driving

    DEFF Research Database (Denmark)

    Martinussen, Laila Marianne; Sømhovd, Mikael Julius; Møller, Mette

    ; further, self-reports of the intention to drive safely (or not) are socially sensitive. Therefore, we examined automatic preferences towards safe and risky driving with a Go/No-go Association Task (GNAT). The results suggest that (1) implicit attitudes towards driving behavior can be measured reliably...... with the GNAT; (2) implicit attitudes towards safe driving versus towards risky driving may be separable constructs. We propose that research on driving behavior may benefit from routinely including measures of implicit cognition. A practical advantage is a lesser susceptibility to social desirability biases......, compared to self-report methods. Pending replication in future research, the apparent dissociation between implicit attitudes towards safe versus risky driving that we observed may contribute to a greater theoretical understanding of the causes of unsafe and risky driving behavior....

  12. Similarity estimators for irregular and age uncertain time series

    Science.gov (United States)

    Rehfeld, K.; Kurths, J.

    2013-09-01

    Paleoclimate time series are often irregularly sampled and age uncertain, which is an important technical challenge to overcome for successful reconstruction of past climate variability and dynamics. Visual comparison and interpolation-based linear correlation approaches have been used to infer dependencies from such proxy time series. While the first is subjective, not measurable and not suitable for the comparison of many datasets at a time, the latter introduces interpolation bias, and both face difficulties if the underlying dependencies are nonlinear. In this paper we investigate similarity estimators that could be suitable for the quantitative investigation of dependencies in irregular and age uncertain time series. We compare the Gaussian-kernel based cross correlation (gXCF, Rehfeld et al., 2011) and mutual information (gMI, Rehfeld et al., 2013) against their interpolation-based counterparts and the new event synchronization function (ESF). We test the efficiency of the methods in estimating coupling strength and coupling lag numerically, using ensembles of synthetic stalagmites with short, autocorrelated, linear and nonlinearly coupled proxy time series, and in the application to real stalagmite time series. In the linear test case coupling strength increases are identified consistently for all estimators, while in the nonlinear test case the correlation-based approaches fail. The lag at which the time series are coupled is identified correctly as the maximum of the similarity functions in around 60-55% (in the linear case) to 53-42% (for the nonlinear processes) of the cases when the dating of the synthetic stalagmite is perfectly precise. If the age uncertainty increases beyond 5% of the time series length, however, the true coupling lag is not identified more often than the others for which the similarity function was estimated. Age uncertainty contributes up to half of the uncertainty in the similarity estimation process. Time series irregularity

  13. Similarity estimators for irregular and age-uncertain time series

    Science.gov (United States)

    Rehfeld, K.; Kurths, J.

    2014-01-01

    Paleoclimate time series are often irregularly sampled and age uncertain, which is an important technical challenge to overcome for successful reconstruction of past climate variability and dynamics. Visual comparison and interpolation-based linear correlation approaches have been used to infer dependencies from such proxy time series. While the first is subjective, not measurable and not suitable for the comparison of many data sets at a time, the latter introduces interpolation bias, and both face difficulties if the underlying dependencies are nonlinear. In this paper we investigate similarity estimators that could be suitable for the quantitative investigation of dependencies in irregular and age-uncertain time series. We compare the Gaussian-kernel-based cross-correlation (gXCF, Rehfeld et al., 2011) and mutual information (gMI, Rehfeld et al., 2013) against their interpolation-based counterparts and the new event synchronization function (ESF). We test the efficiency of the methods in estimating coupling strength and coupling lag numerically, using ensembles of synthetic stalagmites with short, autocorrelated, linear and nonlinearly coupled proxy time series, and in the application to real stalagmite time series. In the linear test case, coupling strength increases are identified consistently for all estimators, while in the nonlinear test case the correlation-based approaches fail. The lag at which the time series are coupled is identified correctly as the maximum of the similarity functions in around 60-55% (in the linear case) to 53-42% (for the nonlinear processes) of the cases when the dating of the synthetic stalagmite is perfectly precise. If the age uncertainty increases beyond 5% of the time series length, however, the true coupling lag is not identified more often than the others for which the similarity function was estimated. Age uncertainty contributes up to half of the uncertainty in the similarity estimation process. Time series irregularity

  14. Prospects for inherently safe reactors

    International Nuclear Information System (INIS)

    Barkenbus, J.N.

    1988-01-01

    Public fears over nuclear safety have led some within the nuclear community to investigate the possibility of producing inherently safe nuclear reactors; that is, reactors that are transparently incapable of producing a core melt. While several promising designs of such reactors have been produced, support for large-scale research and development efforts has not been forthcoming. The prospects for commercialization of inherently safe reactors, therefore, are problematic; possible events such as further nuclear reactor accidents and superpower summits, could alter the present situation significantly. (author)

  15. Current nonclinical testing paradigm enables safe entry to First-In-Human clinical trials: The IQ consortium nonclinical to clinical translational database.

    Science.gov (United States)

    Monticello, Thomas M; Jones, Thomas W; Dambach, Donna M; Potter, David M; Bolt, Michael W; Liu, Maggie; Keller, Douglas A; Hart, Timothy K; Kadambi, Vivek J

    2017-11-01

    The contribution of animal testing in drug development has been widely debated and challenged. An industry-wide nonclinical to clinical translational database was created to determine how safety assessments in animal models translate to First-In-Human clinical risk. The blinded database was composed of 182 molecules and contained animal toxicology data coupled with clinical observations from phase I human studies. Animal and clinical data were categorized by organ system and correlations determined. The 2×2 contingency table (true positive, false positive, true negative, false negative) was used for statistical analysis. Sensitivity was 48% with a 43% positive predictive value (PPV). The nonhuman primate had the strongest performance in predicting adverse effects, especially for gastrointestinal and nervous system categories. When the same target organ was identified in both the rodent and nonrodent, the PPV increased. Specificity was 84% with an 86% negative predictive value (NPV). The beagle dog had the strongest performance in predicting an absence of clinical adverse effects. If no target organ toxicity was observed in either test species, the NPV increased. While nonclinical studies can demonstrate great value in the PPV for certain species and organ categories, the NPV was the stronger predictive performance measure across test species and target organs indicating that an absence of toxicity in animal studies strongly predicts a similar outcome in the clinic. These results support the current regulatory paradigm of animal testing in supporting safe entry to clinical trials and provide context for emerging alternate models. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Effects of the Smartphone Application "Safe Patients" on Knowledge of Patient Safety Issues Among Surgical Patients.

    Science.gov (United States)

    Cho, Sumi; Lee, Eunjoo

    2017-12-01

    Recently, the patient's role in preventing adverse events has been emphasized. Patients who are more knowledgeable about safety issues are more likely to engage in safety initiatives. Therefore, nurses need to develop techniques and tools that increase patients' knowledge in preventing adverse events. For this reason, an educational smartphone application for patient safety called "Safe Patients" was developed through an iterative process involving a literature review, expert consultations, and pilot testing of the application. To determine the effect of "Safe Patients," it was implemented for patients in surgical units in a tertiary hospital in South Korea. The change in patients' knowledge about patient safety was measured using seven true/false questions developed in this study. A one-group pretest and posttest design was used, and a total of 123 of 190 possible participants were tested. The percentage of correct answers significantly increased from 64.5% to 75.8% (P effectively improve patients' knowledge of safety issues. This will ultimately empower patients to engage in safe practices and prevent adverse events related to surgery.

  17. The Impact of Time-Series Diagnostic Tests on the Writing Ability of Iranian EFL learners

    Directory of Open Access Journals (Sweden)

    Bahareh Molazem Atashgahi

    2014-02-01

    Full Text Available This study aimed to show whether administering a battery of time-series diagnostic tests (screening has any impact on Iranian EFL learners’ writing ability. The study was conducted on the intermediate EFL learners at Islamic Azad University North Tehran branch.  The researcher administered a homogenizing test in order to exclude the exceptional scores, among all the testers, only those whose scores were nearly within one standard deviation above or below the mean were selected as the participants of this study. After the assignment of the participants to the control and experimental groups- 30 students in each group- they were asked to write five-paragraph-essays on two topics. Such a pretest was given to both groups to test their initial writing ability. Once scoring of the students’ writings (five- paragraph essay was finished the two means of the groups were calculated and compared with each other through the t-test analysis. The result demonstrated that there was no statistically significant difference between those two groups regarding the variable under investigation. Four sets of diagnostic tests were given to the experimental group every two weeks and after each test both the result of the exam and suitable feedback regarding students’ errors were given to them by the teacher, while the Current-Traditional Rhetoric method was administered in the control group. In the posttest which was run after giving the treatment and placebo to experimental group and control group respectively, students took another writing test with the same characteristics in administration, topics and scoring as the one in pretest. Thereafter, the significance of the difference between the obtained means of experimental and control groups in the posttest was determined through the t-test.  The result of the t-test analysis indicated a significant difference between the two groups which consequently rejected the null hypothesis of the study. Therefore, any

  18. Fasting ramadan in kidney transplant patients is safe

    Directory of Open Access Journals (Sweden)

    Boobes Yousef

    2009-01-01

    Full Text Available Muslims with renal transplant often ask their doctors whether fasting Ramadan is safe. Scanty studies have addressed this question. This prospective study was undertaken to identify any clinical or biological changes with Muslim fasting. 22 kidney transplant patients with stable kidney functions, who were transplanted for more than one year, and voluntarily chose to fast during Ramadan in 1425 H (October-November 2004, were studied. Total of 22 subjects (10 men and 12 women with a mean age of 47 ± 11.6 years were studied. Full clinical and biological assessment was done before during and after the month of Ramadan fasting. Medications were taken in two divided doses at sunset (time of breaking the fast and pre dawn (before the fast. None of the patients experienced any undue fatigue, or symptoms. Body weight, blood pressure, kidney function tests, blood sugar, lipid profile, and cyclosporine levels remained stable. In conclusion it is safe for renal transplant recipients of more than one year and having stable graft function to fast during the month of Ramadan; however caution is advised for moderate to severe impaired renal function.

  19. 50 CFR 216.91 - Dolphin-safe labeling standards.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Dolphin-safe labeling standards. 216.91... MAMMALS Dolphin Safe Tuna Labeling § 216.91 Dolphin-safe labeling standards. (a) It is a violation of... include on the label of those products the term “dolphin-safe” or any other term or symbol that claims or...

  20. Medications: Using Them Safely

    Science.gov (United States)

    ... to Safely Give Ibuprofen Childproofing and Preventing Household Accidents Medicines for Diabetes Complementary and Alternative Medicine How Do Pain Relievers Work? What Medicines Are and What They Do Medicines ...

  1. Normalization methods in time series of platelet function assays

    Science.gov (United States)

    Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham

    2016-01-01

    Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217

  2. Vitamin D Status, Bone Mineral Density and Mental Health in Young Australian Women: The Safe-D Study.

    Science.gov (United States)

    Callegari, Emma T; Reavley, Nicola; Garland, Suzanne M; Gorelik, Alexandra; Wark, John D

    2015-11-17

    Vitamin D deficiency has been associated with both poor bone health and mental ill-health. More recently, a number of studies have found individuals with depressive symptoms tend to have reduced bone mineral density. To explore the interrelationships between vitamin D status, bone mineral density and mental-ill health we are assessing a range of clinical, behavioural and lifestyle factors in young women (Part A of the Safe-D study). Part A of the Safe-D study is a cross-sectional study aiming to recruit 468 young females aged 16-25 years living in Victoria, Australia, through Facebook advertising. Participants are required to complete an extensive, online questionnaire, wear an ultra-violet dosimeter for 14 consecutive days and attend a study site visit. Outcome measures include areal bone mineral measures at the lumbar spine, total hip and whole body, as well as soft tissue composition using dual energy x-ray absorptiometry. Trabecular and cortical volumetric bone density at the tibia is measured using peripheral quantitative computed tomography. Other tests include serum 25-hydroxyvitamin D, serum biochemistry and a range of health markers. Details of mood disorder/s and depressive and anxiety symptoms are obtained by self-report. Cutaneous melanin density is measured by spectrophotometry. The findings of this cross-sectional study will have implications for health promotion in young women and for clinical care of those with vitamin D deficiency and/or mental ill-health. Optimising both vitamin D status and mental health may protect against poor bone health and fractures in later life. Significance for public healthVitamin D deficiency, depression and osteoporosis are all major public health issues. Vitamin D deficiency has been associated with both reduced bone mineral density and depressive symptoms. Moreover, cohort studies have found that subjects with depression have lower bone mineral density when compared to healthy controls. Early adulthood is a critical

  3. Implementation of Safe-by-Design for Nanomaterial Development and Safe Innovation: Why We Need a Comprehensive Approach.

    Science.gov (United States)

    Kraegeloh, Annette; Suarez-Merino, Blanca; Sluijters, Teun; Micheletti, Christian

    2018-04-14

    Manufactured nanomaterials (MNMs) are regarded as key components of innovations in various fields with high potential impact (e.g., energy generation and storage, electronics, photonics, diagnostics, theranostics, or drug delivery agents). Widespread use of MNMs raises concerns about their safety for humans and the environment, possibly limiting the impact of the nanotechnology-based innovation. The development of safe MNMs and nanoproducts has to result in a safe as well as functional material or product. Its safe use, and disposal at the end of its life cycle must be taken into account too. However, not all MNMs are similarly useful for all applications, some might bear a higher hazard potential than others, and use scenarios could lead to different exposure probabilities. To improve both safety and efficacy of nanotechnology, we think that a new proactive approach is necessary, based on pre-regulatory safety assessment and dialogue between stakeholders. On the basis of the work carried out in different European Union (EU) initiatives, developing and integrating MNMs Safe-by-Design and Trusted Environments (NANoREG, ProSafe, and NanoReg2), we present our point of view here. This concept, when fully developed, will allow for cost effective industrial innovation, and an exchange of key information between regulators and innovators. Regulators are thus informed about incoming innovations in good time, supporting a proactive regulatory action. The final goal is to contribute to the nanotechnology governance, having faster, cheaper, effective, and safer nano-products on the market.

  4. Environmental assessment of general-purpose heat source safety verification testing

    International Nuclear Information System (INIS)

    1995-02-01

    This Environmental Assessment (EA) was prepared to identify and evaluate potential environmental, safety, and health impacts associated with the Proposed Action to test General-Purpose Heat Source (GPHS) Radioisotope Thermoelectric Generator (RTG) assemblies at the Sandia National Laboratories (SNL) 10,000-Foot Sled Track Facility, Albuquerque, New Mexico. RTGs are used to provide a reliable source of electrical power on board some spacecraft when solar power is inadequate during long duration space missions. These units are designed to convert heat from the natural decay of radioisotope fuel into electrical power. Impact test data are required to support DOE's mission to provide radioisotope power systems to NASA and other user agencies. The proposed tests will expand the available safety database regarding RTG performance under postulated accident conditions. Direct observations and measurements of GPHS/RTG performance upon impact with hard, unyielding surfaces are required to verify model predictions and to ensure the continual evolution of the RTG designs that perform safely under varied accident environments. The Proposed Action is to conduct impact testing of RTG sections containing GPHS modules with simulated fuel. End-On and Side-On impact test series are planned

  5. Safe havens in Europe: Switzerland and the ten dwarfs

    Directory of Open Access Journals (Sweden)

    Martin Paldam

    2013-12-01

    Full Text Available Eleven safe havens exist in Europe providing offshore banking and low taxes. Ten of these states are very small while Switzerland is moderately small. All 11countries are richer than their large neighbors. It is shown that causality is from small to safe haven towealth, and that theoretically equilibriums are likely to exist where a certain regulation is substantially lower in a small country than in its big neighbor. This generates a large capital inflow to the safe havens. The pool of funds that may reach the safe havens is shown to be huge. It is far in excess of the absorptive capacity of the safe havens, but it still explains, why they are rich. Microstates offer a veil of anonymity to funds passing through, and Switzerland offers safe storage of funds.

  6. Safe and Liquid Mortgage Bonds

    DEFF Research Database (Denmark)

    Dick-Nielsen, Jens; Gyntelberg, Jacob; Lund, Jesper

    This paper shows that strict match pass-through funding of covered bonds provides safe and liquid mortgage bonds. Despite a 30% drop in house prices during the 2008 global crisis Danish mortgage bonds remained as liquid as most European government bonds. The Danish pass-through system effectively...... eliminates credit risk from the investor's perspective. Similar to other safe bonds, funding liquidity becomes the main driver of mortgage bond liquidity and this creates commonality in liquidity across markets and countries. These findings have implications for how to design a robust mortgage bond system...

  7. Layered Ensemble Architecture for Time Series Forecasting.

    Science.gov (United States)

    Rahman, Md Mustafizur; Islam, Md Monirul; Murase, Kazuyuki; Yao, Xin

    2016-01-01

    Time series forecasting (TSF) has been widely used in many application areas such as science, engineering, and finance. The phenomena generating time series are usually unknown and information available for forecasting is only limited to the past values of the series. It is, therefore, necessary to use an appropriate number of past values, termed lag, for forecasting. This paper proposes a layered ensemble architecture (LEA) for TSF problems. Our LEA consists of two layers, each of which uses an ensemble of multilayer perceptron (MLP) networks. While the first ensemble layer tries to find an appropriate lag, the second ensemble layer employs the obtained lag for forecasting. Unlike most previous work on TSF, the proposed architecture considers both accuracy and diversity of the individual networks in constructing an ensemble. LEA trains different networks in the ensemble by using different training sets with an aim of maintaining diversity among the networks. However, it uses the appropriate lag and combines the best trained networks to construct the ensemble. This indicates LEAs emphasis on accuracy of the networks. The proposed architecture has been tested extensively on time series data of neural network (NN)3 and NN5 competitions. It has also been tested on several standard benchmark time series data. In terms of forecasting accuracy, our experimental results have revealed clearly that LEA is better than other ensemble and nonensemble methods.

  8. Occupational exposure to mercury. What is a safe level?

    OpenAIRE

    Moienafshari, R.; Bar-Oz, B.; Koren, G.

    1999-01-01

    QUESTION: One of my pregnant patients, a dental hygienist, uses mercury in her workplace, but appears to have no symptoms of mercury toxicity. She has heard that mercury might affect her fetus. What should I recommend to her? What is a safe level of mercury in the air for pregnant women? ANSWER: Testing for levels of mercury in whole blood and, preferably, urine is useful for confirming exposure. Currently, mercury vapour concentrations greater than 0.01 mg/m3 are considered unsafe. Also, wom...

  9. Fourier series

    CERN Document Server

    Tolstov, Georgi P

    1962-01-01

    Richard A. Silverman's series of translations of outstanding Russian textbooks and monographs is well-known to people in the fields of mathematics, physics, and engineering. The present book is another excellent text from this series, a valuable addition to the English-language literature on Fourier series.This edition is organized into nine well-defined chapters: Trigonometric Fourier Series, Orthogonal Systems, Convergence of Trigonometric Fourier Series, Trigonometric Series with Decreasing Coefficients, Operations on Fourier Series, Summation of Trigonometric Fourier Series, Double Fourie

  10. Implementation of an Improved Safe Operating Envelope

    International Nuclear Information System (INIS)

    Prime, Robyn; McIntyre, Mark; Reeves, David

    2008-01-01

    This paper is a continuation of the paper presented at IYNC 2004 on 'The Definition of a Safe Operating Envelope'. The current paper concentrates on the implementation process of the Safe Operating Envelope employed at the Point Lepreau Generating Station. (authors)

  11. ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.

    Science.gov (United States)

    Jeong, Jongtae; Ko, Nak Yul; Cho, Dong-Keun; Baik, Min Hoon; Yoon, Ki-Hoon

    2018-03-16

    Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculated the exposure dose and mass of NORM waste to be disposed in landfill site by considering the activity concentration level and exposure dose. In 2012, the Korean government promulgated an act on the safety control of NORM around living environments to protect human health and the environment. For the successful implementation of this act, we suggest a reference design for a landfill for the disposal of NORM waste. Based on this reference landfill, we estimate the maximum exposure doses and the relative impact of each pathway to exposure dose for three scenarios: a reference scenario, an ingestion pathway exclusion scenario, and a low leach rate scenario. Also, we estimate the possible quantity of NORM waste disposal into a landfill as a function of the activity concentration level of U series, Th series and 40K and two kinds of exposure dose levels, 1 and 0.3 mSv/y. The results of this study can be used to support the establishment of technical bases of the management strategy for the safe disposal of NORM waste.

  12. Stock Photographs Do Not Comply With Infant Safe Sleep Guidelines.

    Science.gov (United States)

    Goodstein, Michael H; Lagon, Elena; Bell, Theodore; Joyner, Brandi L; Moon, Rachel Y

    2018-04-01

    We evaluated images in popular stock photography websites for adherence with American Academy of Pediatrics (AAP) guidelines for safe infant sleep practices. Three top stock photo websites were used to collect photographs generated from key phrases. All images depicting an infant sleep environment were analyzed for consistency with AAP guidelines. Descriptive statistics, chi-square and z test of proportions, were conducted. A total of 1233 of 1947 stock photographs showed sleeping infants on a flat surface. In all, 627 (50.8%) photographs showed the infant in the supine position and 79 (5%) of all infant sleep environments were adherent with AAP recommendations. Bedding inconsistent with safe sleep recommendations was identified in 1133 images (71.3%), with blankets noted in 49.5%. Images depicting sleeping infants on stock photography sites do not routinely adhere to AAP recommendations. Media messages inconsistent with health care messages create confusion and misinformation about infant sleep safety and may lead inadvertently to unsafe practices.

  13. High energy eye-safe and mid-infrared optical parametric oscillator

    International Nuclear Information System (INIS)

    Liu, J; Liu, Q; Huang, L; Gong, M

    2010-01-01

    A high energy eye-safe and mid-infrared optical parametric oscillator (OPO) is demonstrated. The nonlinear media is a Y-cut KTA crystal with the length of 20 mm, which is pumped by a Nd:YAG laser. Both eye-safe and mid-infrared laser are output with high energy. When the pump energy is 1 J and the pulse duration is 10 ns, we get 53 mJ idler at 3.632 μm and 151 mJ signal at 1.505 μm. As we know, the idler energy is the highest at the wavelength beyond 3.5 μm and the signal energy is the highest with Y-cut KTA. The results prove that the Y-cut KTA crystal can produce the signal and idler with the energies as high as these in the paper. We have tested the temperature-tuning characters and the coefficient of the idler is 0.26 nm/°C

  14. Adaptive time-variant models for fuzzy-time-series forecasting.

    Science.gov (United States)

    Wong, Wai-Keung; Bai, Enjian; Chu, Alice Wai-Ching

    2010-12-01

    A fuzzy time series has been applied to the prediction of enrollment, temperature, stock indices, and other domains. Related studies mainly focus on three factors, namely, the partition of discourse, the content of forecasting rules, and the methods of defuzzification, all of which greatly influence the prediction accuracy of forecasting models. These studies use fixed analysis window sizes for forecasting. In this paper, an adaptive time-variant fuzzy-time-series forecasting model (ATVF) is proposed to improve forecasting accuracy. The proposed model automatically adapts the analysis window size of fuzzy time series based on the prediction accuracy in the training phase and uses heuristic rules to generate forecasting values in the testing phase. The performance of the ATVF model is tested using both simulated and actual time series including the enrollments at the University of Alabama, Tuscaloosa, and the Taiwan Stock Exchange Capitalization Weighted Stock Index (TAIEX). The experiment results show that the proposed ATVF model achieves a significant improvement in forecasting accuracy as compared to other fuzzy-time-series forecasting models.

  15. Implementation of an Improved Safe Operating Envelope

    Energy Technology Data Exchange (ETDEWEB)

    Prime, Robyn; McIntyre, Mark [NB Power Nuclear, P.O. Box 600, Lepreau, NB (Canada); Reeves, David [Atlantic Nuclear Services Ltd., PO Box 1268 Fredericton, NB (Canada)

    2008-07-01

    This paper is a continuation of the paper presented at IYNC 2004 on 'The Definition of a Safe Operating Envelope'. The current paper concentrates on the implementation process of the Safe Operating Envelope employed at the Point Lepreau Generating Station. (authors)

  16. From Safe Systems to Patient Safety

    DEFF Research Database (Denmark)

    Aarts, J.; Nøhr, C.

    2010-01-01

    for the third conference with the theme: The ability to design, implement and evaluate safe, useable and effective systems within complex health care organizations. The theme for this conference was "Designing and Implementing Health IT: from safe systems to patient safety". The contributions have reflected...... and implementation of safe systems and thus contribute to the agenda of patient safety? The contributions demonstrate how the health informatics community has contributed to the performance of significant research and to translating research findings to develop health care delivery and improve patient safety......This volume presents the papers from the fourth International Conference on Information Technology in Health Care: Socio-technical Approaches held in Aalborg, Denmark in June 2010. In 2001 the first conference was held in Rotterdam, The Netherlands with the theme: Sociotechnical' approaches...

  17. The first safe country

    Directory of Open Access Journals (Sweden)

    Raffaela Puggioni

    2012-06-01

    Full Text Available The Dublin II Regulation makes the first safe country of refuge solelyresponsible for refugees and asylum seekers. In the case of Italy, thefirst responsible country has not been acting responsibly.

  18. Karate: Keep It Safe.

    Science.gov (United States)

    Jordan, David

    1981-01-01

    Safety guidelines for each phase of a karate practice session are presented to provide an accident-free and safe environment for teaching karate in a physical education or traditional karate training program. (JMF)

  19. Level of awareness of cervical and breast cancer risk factors and safe practices among college teachers of different states in india: do awareness programmes have an impact on adoption of safe practices?

    Science.gov (United States)

    Shankar, Abhishek; Rath, Gk; Roy, Shubham; Malik, Abhidha; Bhandari, Ruchir; Kishor, Kunal; Barnwal, Keshav; Upadyaya, Sneha; Srivastava, Vivek; Singh, Rajan

    2015-01-01

    Breast and cervical cancers are the most common causes of cancer mortality among women in India, but actually they are largely preventable diseases. Although early detection is the only way to reduce morbidity and mortality, there are limited data on breast and cervical cancer knowledge, safe practices and attitudes of teachers in India. The purpose of this study is to assess the level of awareness and impact of awareness programs in adoption of safe practices in prevention and early detection. This assessment was part of a pink chain campaign on cancer awareness. During cancer awareness events in 2011 at various women colleges in different parts in India, a pre-test related to cervical cancer and breast cancer was followed by an awareness program. Post-tests using the same questionnaire were conducted at the end of the interactive session, at 6 months and 1 year. A total of 156 out of 182 teachers participated in the study (overall response rate was 85.7 %). Mean age of the study population was 42.4 years (range- 28-59 yrs). There was a significant increase in level of knowledge regarding cervical and breast cancer at 6 months and this was sustained at 1 year. Adoption of breast self examination (BSE) was significantly more frequent in comparison to CBE, mammography and the Pap test. Magazines and newspapers were sources for knowledge regarding screening tests for breast cancer in more than 60% of teachers where as more than 75% were educated by doctors regarding the Pap test. Post awareness at 6 months and 1 year, there was a significant change in alcohol and smoking habits. Major reasons for not doing screening test were found to be ignorance (50%), lethargic attitude (44.8%) and lack of time (34.6%). Level of knowledge of breast cancer risk factors, symptoms and screening methods was high as compared to cervical cancer. There was a significant increase in level of knowledge regarding cervical and breast cancer at 6 months and this was sustained at 1 year

  20. Design and application of a new series of gallbladder endoscopes that facilitate gallstone removal without gallbladder excision

    Science.gov (United States)

    Qiao, Tie; Huang, Wan-Chao; Luo, Xiao-Bing; Zhang, Yang-De

    2012-01-01

    In recent years, some Chinese doctors have proposed a new concept, gallstone removal without gallbladder excision, along with transition of the medical model. As there is no specialized endoscope for gallstone removal without gallbladder excision, we designed and produced a new series of gallbladder endoscopes and accessories that have already been given a Chinese invention patent (No. ZL200810199041.2). The design of these gallbladder endoscopes was based on the anatomy and physiology of the gallbladder, characteristics of gallbladder disease, ergonomics, and industrial design. This series of gallbladder endoscopes underwent clinical trials in two hospitals appointed by the State Administration of Traditional Chinese Medicine. The clinical trials showed that surgeries of gallstones, gallbladder polyps, and cystic duct calculus could be smoothly performed with these products. In summary, this series of gallbladder endoscopes is safe, reliable, and effective for gallstone removal without gallbladder excision. This note comprehensively introduces the research and design of this series of gallbladder endoscopes.

  1. Prepare to protect: Operating and maintaining a tornado safe room.

    Science.gov (United States)

    Herseth, Andrew; Goldsmith-Grinspoon, Jennifer; Scott, Pataya

    2017-06-01

    Operating and maintaining a tornado safe room can be critical to the effective continuity of business operations because a firm's most valuable asset is its people. This paper describes aspects of operations and maintenance (O&M) for existing tornado safe rooms as well as a few planning and design aspects that affect the ultimate operation of a safe room for situations where a safe room is planned, but not yet constructed. The information is based on several Federal Emergency Management Agency safe room publications that provide guidance on emergency management and operations, as well as the design and construction of tornado safe rooms.

  2. Safe actinide disposition in molten salt reactors

    International Nuclear Information System (INIS)

    Gat, U.

    1997-01-01

    Safe molten salt reactors (MSR) can readily accommodate the burning of all fissile actinides. Only minor compromises associated with plutonium are required. The MSRs can dispose safely of actinides and long lived isotopes to result in safer and simpler waste. Disposing of actinides in MSRs does increase the source term of a safety optimized MSR. It is concluded that the burning and transmutation of actinides in MSRs can be done in a safe manner. Development is needed for the processing to handle and separate the actinides. Calculations are needed to establish the neutron economy and the fuel management. 9 refs

  3. Safe Sleep for Babies

    Science.gov (United States)

    ... 5 MB] Read the MMWR Science Clips Safe Sleep for Babies Eliminating hazards Recommend on Facebook Tweet ... Page Problem Every year, there are thousands of sleep-related deaths among babies. View large image and ...

  4. Functional DNA: Teaching Infinite Series through Genetic Analogy

    Science.gov (United States)

    Kowalski, R. Travis

    2011-01-01

    This article presents an extended analogy that connects infinite sequences and series to the science of genetics, by identifying power series as "DNA for a function." This analogy allows standard topics such as convergence tests or Taylor approximations to be recast in a "forensic" light as mathematical analogs of genetic concepts such as DNA…

  5. American Contact Dermatitis Society Core Allergen Series: 2017 Update.

    Science.gov (United States)

    Schalock, Peter C; Dunnick, Cory A; Nedorost, Susan; Brod, Bruce; Warshaw, Erin; Mowad, Christen

    The American Contact Dermatitis Society Core Allergen Series was introduced in 2012. After 4 years of use, changes in our recommended allergens are necessary. For the updated series, we have reordered the first 4 panels to approximately mirror the current TRUE Test and removed parthenolide, triclosan, glutaraldehyde, and jasmine. Polymyxin B, lavender, sodium benzoate, ethylhexylglycerin, and benzoic acid are new additions to the American Contact Dermatitis Society series.

  6. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos

    2012-01-01

    The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in consecutiv...

  7. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    NARCIS (Netherlands)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos; Fernandez-Vozmediano, José M; Ayala, Fabio; Balato, Anna; Bauer, Andrea; Ballmer-Weber, Barbara; Beliauskiene, Aiste; Fortina, Anna Belloni; Bircher, Andreas; Brasch, Jochen; Chowdhury, Mahbub M U; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise; Cooper, Sue; Czarnecka-Operacz, Magda; Zmudzinska, Maria; Elsner, Peter; English, John S C; Frosch, Peter J; Fuchs, Thomas; García-Gavín, Juan; Fernández-Redondo, Virginia; Gawkrodger, David J; Giménez-Arnau, Ana; Green, Cathy M; Horne, Helen L; Johansen, Jeanne Duus; Jolanki, Riitta; Pesonen, Maria; King, Clodagh M; Krêcisz, Beata; Chomiczewska, Dorota; Kiec-Swierczynska, Marta; Larese, Francesca; Mahler, Vera; Ormerod, Anthony D; Peserico, Andrea; Rantanen, Tapio; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Sansom, Jane E; Silvestre, Juan Fco; Simon, Dagmar; Spiewak, Radoslaw; Statham, Barry N; Stone, Natalie; Wilkinson, Mark; Schnuch, Axel

    BACKGROUND: The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in

  8. Working safely with electronics racks

    CERN Document Server

    Simon Baird, HSE Unit Head

    2016-01-01

    Think of CERN and you’ll probably think of particle accelerators and detectors. These are the tools of the trade in particle physics, but behind them are the racks of electronics that include power supplies, control systems and data acquisition networks.   Inside an electronics rack: danger could be lurking if the rack is not powered off. In routine operation, these are no more harmful than the home entertainment system in your living room. But unscrew the cover and it’s a different matter. Even after following appropriate training, and with formal authorisation from your group leader or equivalent to carry out electrical work or any work in the vicinity of electrical hazards, and even with extensive experience of carrying out such operations, it’s important to incorporate safe working practices into your routine. At CERN, before the racks of electronics reach their operational configurations for the accelerators and detectors, they play a vital role in test set-ups ...

  9. Pediatric Cardiopulmonary Arrest in the Postanesthesia Care Unit, Rare but Preventable: Analysis of Data From Wake Up Safe, The Pediatric Anesthesia Quality Improvement Initiative.

    Science.gov (United States)

    Christensen, Robert E; Haydar, Bishr; Voepel-Lewis, Terri D

    2017-04-01

    Nearly 20% of anesthesia-related pediatric cardiac arrests (CAs) occur during emergence or recovery. The aims of this case series were to use the Wake Up Safe database to describe the following: (1) the nature of pediatric postanesthesia care unit (PACU) CA and subsequent outcomes and (2) factors associated with harm after pediatric PACU CA. Pediatric CAs in the PACU were identified from the Wake Up Safe Pediatric Anesthesia Quality Improvement Initiative, a multicenter registry of adverse events in pediatric anesthesia. Demographics, underlying conditions, cause of CA, and outcomes were extracted. Descriptive statistics were used to characterize data and to assess risk of harm in those suffering CA. A total of 26 CA events were included: 67% in children anesthesia care providers until emergence from anesthesia may further reduce the preventable arrest rate. The root cause analyses conducted by individual institutions reporting these data to the Wake Up Safe provided only limited insight, so multicenter collaborative approaches may allow for greater insight into effective CA-prevention strategies.

  10. Application of the Laplace transform method for computational modelling of radioactive decay series

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Deise L.; Damasceno, Ralf M.; Barros, Ricardo C. [Univ. do Estado do Rio de Janeiro (IME/UERJ) (Brazil). Programa de Pos-graduacao em Ciencias Computacionais

    2012-03-15

    It is well known that when spent fuel is removed from the core, it is still composed of considerable amount of radioactive elements with significant half-lives. Most actinides, in particular plutonium, fall into this category, and have to be safely disposed of. One solution is to store the long-lived spent fuel as it is, by encasing and burying it deep underground in a stable geological formation. This implies estimating the transmutation of these radioactive elements with time. Therefore, we describe in this paper the application of the Laplace transform technique in matrix formulation to analytically solve initial value problems that mathematically model radioactive decay series. Given the initial amount of each type of radioactive isotopes in the decay series, the computer code generates the amount at a given time of interest, or may plot a graph of the evolution in time of the amount of each type of isotopes in the series. This computer code, that we refer to as the LTRad{sub L} code, where L is the number of types of isotopes belonging to the series, was developed using the Scilab free platform for numerical computation and can model one segment or the entire chain of any of the three radioactive series existing on Earth today. Numerical results are given to typical model problems to illustrate the computer code efficiency and accuracy. (orig.)

  11. Application of the Laplace transform method for computational modelling of radioactive decay series

    International Nuclear Information System (INIS)

    Oliveira, Deise L.; Damasceno, Ralf M.; Barros, Ricardo C.

    2012-01-01

    It is well known that when spent fuel is removed from the core, it is still composed of considerable amount of radioactive elements with significant half-lives. Most actinides, in particular plutonium, fall into this category, and have to be safely disposed of. One solution is to store the long-lived spent fuel as it is, by encasing and burying it deep underground in a stable geological formation. This implies estimating the transmutation of these radioactive elements with time. Therefore, we describe in this paper the application of the Laplace transform technique in matrix formulation to analytically solve initial value problems that mathematically model radioactive decay series. Given the initial amount of each type of radioactive isotopes in the decay series, the computer code generates the amount at a given time of interest, or may plot a graph of the evolution in time of the amount of each type of isotopes in the series. This computer code, that we refer to as the LTRad L code, where L is the number of types of isotopes belonging to the series, was developed using the Scilab free platform for numerical computation and can model one segment or the entire chain of any of the three radioactive series existing on Earth today. Numerical results are given to typical model problems to illustrate the computer code efficiency and accuracy. (orig.)

  12. Escola segura Safe school

    Directory of Open Access Journals (Sweden)

    Edson Ferreira Liberal

    2005-11-01

    Full Text Available OBJETIVO: Revisão das estratégias para tornar o ambiente escolar seguro. Inicialmente os autores contextualizam a violência e os acidentes no ambiente escolar e fazem recomendações, baseadas em dados da literatura, para a implantação de escolas seguras. FONTE DE DADOS: Artigos publicados entre 1993 e 2005 na base de dados MEDLINE. Dados nacionais epidemiológicos e da literatura também foram pesquisados. SÍNTESE DOS DADOS: Há evidência crescente de que a intervenção tem múltiplos componentes. O foco político é a prática em educação em saúde com o envolvimento de toda a comunidade. O norte dessas intervenções é ajudar estudantes e toda a comunidade a adotar um comportamento seguro e saudável. As escolas estão assumindo um envolvimento crescente na promoção da saúde, prevenção de doenças e prevenção de trauma. Nesse contexto de prevenção de causas externas de morbimortalidade, é importante reconhecer o risco ambiental, locais e comportamentos de risco como favoráveis ao trauma e à violência, além de um novo conceito de acidentes como algo que possa ser evitado. CONCLUSÃO: A implementação da escola segura representa uma nova direção promissora para o trabalho preventivo baseado na escola. É importante notar que uma escola segura deve intervir não meramente na sua estrutura física, mas também torná-la tão segura quanto possível, trabalhando com a comunidade escolar por meio de educação em saúde, discutindo principalmente o comportamento saudável.OBJECTIVE: To review the strategies to make school a safe environment. The paper first addresses the social context of accidents and violence in the school environment, and makes recommendations, based on the literature data, for the implementation of safe schools. SOURCE OF DATA: Articles published between 1993 and 2005 in the MEDLINE database. Brazilian epidemiological and literature data have also been searched. SUMMARY OF THE FINDINGS: There is

  13. Buying & Using Medicine Safely

    Science.gov (United States)

    ... Reducers Safe Daily Use of Aspirin Medication Health Fraud Resources for You FDA Consumer Updates (Drugs) Page ... feeds Follow FDA on Twitter Follow FDA on Facebook View FDA videos on YouTube View FDA photos ...

  14. Training Guidelines in Non-Destructive Testing Techniques: Manual for Visual Testing at Level 2

    International Nuclear Information System (INIS)

    2013-01-01

    The International Atomic Energy Agency (IAEA) has been active in the promotion of non-destructive testing (NDT) technology for many decades. The prime reason for this interest has been the need for stringent quality control standards for safe operation of nuclear as well as other industrial installations. The IAEA has successfully executed a number of projects, including technical cooperation projects (national and regional) and coordinated research projects, in which NDT was an important part. Through these projects, a large number of persons have been trained in numerous Member States, leading to the establishment of national certifying bodies responsible for training and certification of NDT personnel. Consequently a state of self-sufficiency in this area of technology has been achieved in many of these States. All along there has been a realization of the need to have well established training guidelines and related books, in order, first, to guide IAEA experts involved in this training programme and, second, to achieve some level of international uniformity and harmonization of training materials and consequent competence of NDT personnel. The syllabuses for training courses have been published in the form of TECDOC publications. The first was IAEA-TECDOC-407 (1987), which contained syllabuses for the five basic NDT methods: liquid penetrant testing, magnetic particle testing, eddy current testing, radiographic testing and ultrasonic testing. To accommodate advancements in NDT technology, later versions of this publication were issued in 1991, 2002 and 2008, with the current version being IAEA-TECDOC- 628/Rev.2 (2008), which includes additional and more advanced NDT methods. The next logical step was to compile textbooks and training manuals in accordance with these syllabuses. Manuals on liquid penetrant, magnetic particle, radiographic, ultrasonic and eddy current testing have already been published in the Training Course Series. These play a vital role in

  15. `Indoor` series vending machines; `Indoor` series jido hanbaiki

    Energy Technology Data Exchange (ETDEWEB)

    Gensui, T.; Kida, A. [Fuji Electric Co. Ltd., Tokyo (Japan); Okumura, H. [Fuji Denki Reiki Co. Ltd., Tokyo (Japan)

    1996-07-10

    This paper introduces three series of vending machines that were designed to match the interior of an office building. The three series are vending machines for cups, paper packs, cans, and tobacco. Among the three series, `Interior` series has a symmetric design that was coated in a grain pattern. The inside of the `Interior` series is coated by laser satin to ensure a sense of superior quality and a refined style. The push-button used for product selection is hot-stamped on the plastic surface to ensure the hair-line luster. `Interior Phase II` series has a bay window design with a sense of superior quality and lightness. The inside of the `Interior Phase II` series is coated by laser satin. `Interior 21` series is integrated with the wall except the sales operation panel. The upper and lower dress panels can be detached and attached. The door lock is a wire-type structure with high operativity. The operation block is coated by titanium color. The dimensions of three series are standardized. 6 figs., 1 tab.

  16. A new bootstrap test for multiple assets joint risk testing

    NARCIS (Netherlands)

    Ardia, David; Gatarek, Lukasz; Hoogerheide, Lennart F.

    2017-01-01

    In this paper, a novel simulation-based methodology is proposed to test the validity of a set of marginal time series models, where the dependence structure between the time series is taken directly from the observed data. The procedure is useful when one wants to summarize the test results for

  17. FAST: towards safe and effective subcutaneous immunotherapy of persistent life-threatening food allergies

    Directory of Open Access Journals (Sweden)

    Zuidmeer-Jongejan Laurian

    2012-03-01

    Full Text Available Abstract The FAST project (Food Allergy Specific Immunotherapy aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT, using subcutaneous injections with aqueous food extracts may be effective but has proven to be accompanied by too many anaphylactic side-effects. FAST aims to develop a safe alternative by replacing food extracts with hypoallergenic recombinant major allergens as the active ingredients of SIT. Both severe fish and peach allergy are caused by a single major allergen, parvalbumin (Cyp c 1 and lipid transfer protein (Pru p 3, respectively. Two approaches are being evaluated for achieving hypoallergenicity, i.e. site-directed mutagenesis and chemical modification. The most promising hypoallergens will be produced under GMP conditions. After pre-clinical testing (toxicology testing and efficacy in mouse models, SCIT with alum-absorbed hypoallergens will be evaluated in phase I/IIa and IIb randomized double-blind placebo-controlled (DBPC clinical trials, with the DBPC food challenge as primary read-out. To understand the underlying immune mechanisms in depth serological and cellular immune analyses will be performed, allowing identification of novel biomarkers for monitoring treatment efficacy. FAST aims at improving the quality of life of food allergic patients by providing a safe and effective treatment that will significantly lower their threshold for fish or peach intake, thereby decreasing their anxiety and dependence on rescue medication.

  18. FAST: towards safe and effective subcutaneous immunotherapy of persistent life-threatening food allergies

    Science.gov (United States)

    2012-01-01

    The FAST project (Food Allergy Specific Immunotherapy) aims at the development of safe and effective treatment of food allergies, targeting prevalent, persistent and severe allergy to fish and peach. Classical allergen-specific immunotherapy (SIT), using subcutaneous injections with aqueous food extracts may be effective but has proven to be accompanied by too many anaphylactic side-effects. FAST aims to develop a safe alternative by replacing food extracts with hypoallergenic recombinant major allergens as the active ingredients of SIT. Both severe fish and peach allergy are caused by a single major allergen, parvalbumin (Cyp c 1) and lipid transfer protein (Pru p 3), respectively. Two approaches are being evaluated for achieving hypoallergenicity, i.e. site-directed mutagenesis and chemical modification. The most promising hypoallergens will be produced under GMP conditions. After pre-clinical testing (toxicology testing and efficacy in mouse models), SCIT with alum-absorbed hypoallergens will be evaluated in phase I/IIa and IIb randomized double-blind placebo-controlled (DBPC) clinical trials, with the DBPC food challenge as primary read-out. To understand the underlying immune mechanisms in depth serological and cellular immune analyses will be performed, allowing identification of novel biomarkers for monitoring treatment efficacy. FAST aims at improving the quality of life of food allergic patients by providing a safe and effective treatment that will significantly lower their threshold for fish or peach intake, thereby decreasing their anxiety and dependence on rescue medication. PMID:22409908

  19. Virus Alert: Ten Steps to Safe Computing.

    Science.gov (United States)

    Gunter, Glenda A.

    1997-01-01

    Discusses computer viruses and explains how to detect them; discusses virus protection and the need to update antivirus software; and offers 10 safe computing tips, including scanning floppy disks and commercial software, how to safely download files from the Internet, avoiding pirated software copies, and backing up files. (LRW)

  20. Safe driving for teens

    Science.gov (United States)

    Driving and teenagers; Teens and safe driving; Automobile safety - teenage drivers ... months before taking friends as passengers. Teenage-related driving deaths occur more often in certain conditions. OTHER SAFETY TIPS FOR TEENS Reckless driving is still a ...

  1. A Standardized Shift Handover Protocol: Improving Nurses’ Safe Practice in Intensive Care Units

    Directory of Open Access Journals (Sweden)

    Javad Malekzadeh

    2013-08-01

    Full Text Available Introduction: For maintaining the continuity of care and improving the quality of care, effective inter-shift information communication is necessary. Any handover error can endanger patient safety. Despite the importance of shift handover, there is no standard handover protocol in our healthcare settings. Methods In this one-group pretest-posttest quasi-experimental study conducted in spring and summer of 2011, we recruited a convenience sample of 56 ICU nurses. The Nurses’ Safe Practice Evaluation Checklist was used for data collection. The Content Validity Index and the inter-rater correlation coefficient of the checklist was 0.92 and 89, respectively. We employed the SPSS 11.5 software and the Mc Nemar and paired-samples t test for data analysis. Results: Study findings revealed that nurses’ mean score on the Safe Practice Evaluation Checklist increased significantly from 11.6 (2.7 to 17.0 (1.8 (P < 0.001. Conclusion: using a standard handover protocol for communicating patient’s needs and information improves nurses’ safe practice in the area of basic nursing care.

  2. Testing Non-Stationarity in Selected Macroeconomic Series from ...

    African Journals Online (AJOL)

    The study tested stationarity in a selected set of macroeconomic variables (some constructed) from Sudan over the period 1969 to 1998. Augmented Dickey Fuller tests were employed to test for presence of unit roots. The study found that unit roots existed in most variables, namely, private investment, public investment, real ...

  3. Characterizing interdependencies of multiple time series theory and applications

    CERN Document Server

    Hosoya, Yuzo; Takimoto, Taro; Kinoshita, Ryo

    2017-01-01

    This book introduces academic researchers and professionals to the basic concepts and methods for characterizing interdependencies of multiple time series in the frequency domain. Detecting causal directions between a pair of time series and the extent of their effects, as well as testing the non existence of a feedback relation between them, have constituted major focal points in multiple time series analysis since Granger introduced the celebrated definition of causality in view of prediction improvement. Causality analysis has since been widely applied in many disciplines. Although most analyses are conducted from the perspective of the time domain, a frequency domain method introduced in this book sheds new light on another aspect that disentangles the interdependencies between multiple time series in terms of long-term or short-term effects, quantitatively characterizing them. The frequency domain method includes the Granger noncausality test as a special case. Chapters 2 and 3 of the book introduce an i...

  4. Detecting nonlinear structure in time series

    International Nuclear Information System (INIS)

    Theiler, J.

    1991-01-01

    We describe an approach for evaluating the statistical significance of evidence for nonlinearity in a time series. The formal application of our method requires the careful statement of a null hypothesis which characterizes a candidate linear process, the generation of an ensemble of ''surrogate'' data sets which are similar to the original time series but consistent with the null hypothesis, and the computation of a discriminating statistic for the original and for each of the surrogate data sets. The idea is to test the original time series against the null hypothesis by checking whether the discriminating statistic computed for the original time series differs significantly from the statistics computed for each of the surrogate sets. While some data sets very cleanly exhibit low-dimensional chaos, there are many cases where the evidence is sketchy and difficult to evaluate. We hope to provide a framework within which such claims of nonlinearity can be evaluated. 5 refs., 4 figs

  5. Experiment data report for semiscale Mod-2A primary feed and bleed experiment series (Tests S-SR-1 and S-SR-2)

    International Nuclear Information System (INIS)

    Fogdall, S.P.

    1982-10-01

    This report presents test data recorded for Tests S-SR-1 and S-SR-2 of the Semiscale Mod-2A Primary Feed and Bleed Tests. These tests are part of a series of Semiscale tests that investigate the thermal-hydraulic phenomena resulting from a hypothesized loss-of-coolant accident (LOCA) or abnormal operating transient. These tests provide experimental data for assessing the analytical capability of computer codes used in LOCA and operational transient analysis. The primary objectives of Tests S-SR-1 and -2 were to provide data on primary system recovery through the use of primary feed and bleed cooling, with no heat transfer to the secondaries. Data was obtained using high- and low-head pump curves for the safety injection (SI) pumps. This report presents the uninterpreted data from Tests S-SR-1 and -2 for analysis. The data, presented as graphs in engineering units, have been analyzed only to the extent necessary to ensure that they are reasonable and consistent

  6. Data imputation analysis for Cosmic Rays time series

    Science.gov (United States)

    Fernandes, R. C.; Lucio, P. S.; Fernandez, J. H.

    2017-05-01

    The occurrence of missing data concerning Galactic Cosmic Rays time series (GCR) is inevitable since loss of data is due to mechanical and human failure or technical problems and different periods of operation of GCR stations. The aim of this study was to perform multiple dataset imputation in order to depict the observational dataset. The study has used the monthly time series of GCR Climax (CLMX) and Roma (ROME) from 1960 to 2004 to simulate scenarios of 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80% and 90% of missing data compared to observed ROME series, with 50 replicates. Then, the CLMX station as a proxy for allocation of these scenarios was used. Three different methods for monthly dataset imputation were selected: AMÉLIA II - runs the bootstrap Expectation Maximization algorithm, MICE - runs an algorithm via Multivariate Imputation by Chained Equations and MTSDI - an Expectation Maximization algorithm-based method for imputation of missing values in multivariate normal time series. The synthetic time series compared with the observed ROME series has also been evaluated using several skill measures as such as RMSE, NRMSE, Agreement Index, R, R2, F-test and t-test. The results showed that for CLMX and ROME, the R2 and R statistics were equal to 0.98 and 0.96, respectively. It was observed that increases in the number of gaps generate loss of quality of the time series. Data imputation was more efficient with MTSDI method, with negligible errors and best skill coefficients. The results suggest a limit of about 60% of missing data for imputation, for monthly averages, no more than this. It is noteworthy that CLMX, ROME and KIEL stations present no missing data in the target period. This methodology allowed reconstructing 43 time series.

  7. Safe operation of critical assemblies and research reactors

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1960-09-15

    Some countries have accumulated considerable experience in the operation of these reactors and have in the process developed safe practices. On the other hand, other countries which have recently acquired, or will soon acquire, such reactors do not have sufficient background of experience with them to have developed full knowledge regarding their safe operation. In this situation, the International Atomic Energy Agency has considered that it would be useful to make available to all its Member States a set of recommendations on the safe operation of these reactors, based on the accumulated experience and best practices. The Director General accordingly nominated a Pane Ion Safe Operation of Critical Assemblies and Research Reactors to assist the Agency's Secretariat in drafting such recommendations

  8. Conductive Cotton Textile from Safely Functionalized Carbon Nanotubes

    Directory of Open Access Journals (Sweden)

    Mohammad Jellur Rahman

    2015-01-01

    Full Text Available Electroconductive cotton textile has been prepared by a simple dipping-drying coating technique using safely functionalized multiwalled carbon nanotubes (f-MWCNTs. Owing to the surface functional groups, the f-MWCNTs become strongly attached with the cotton fibers forming network armors on their surfaces. As a result, the textile exhibits enhanced electrical properties with improved thermal conductivity and therefore is demonstrated as a flexible electrothermal heating element. The fabricated f-MWCNTs/cotton textile can be heated uniformly from room temperature to ca. 100°C within few minutes depending on the applied voltage. The textile shows good thermal stability and repeatability during a long-term heating test.

  9. Elaboration of Safe Community Assessment System

    Directory of Open Access Journals (Sweden)

    Birutė Mikulskienė

    2013-08-01

    Full Text Available The paper aims to design an assessment system to monitor and evaluate safety parameters and administrative efforts with the purpose to increase safety in municipalities. The safety monitoring system considered is to be the most important tool for creation and development of safe communities in Lithuania. Several methods were applied to achieve this purpose. In order to determine the role of local government in ensuring the safety of people, property and environment at the local level of a meta-analysis of research reports, the Lithuanian national legislation, strategic planning documents of the state and local government were carried out. Analysis of statistical data, structural analysis, comparative analysis and synthesis methods were used while investigating the areas of safety uncertainty, risk groups, identifying safety risk factors, determining their relationship, and creating a safe community assessment system. A safe community assessment system, which consists of two types of criteria, has been elaborated. The assessment system is based on the multi-level criteria for safety monitoring and the multi-level criteria for the evaluation of municipal activities in the field of building safety. Links between the criteria, peculiarities of their application and advantages in the process of safe community creation and development are analyzed. Design and implementation of the safe community assessment system is one of the most important stages to implement the idea of safe communities. The proposed system integrates a variety of risk areas, the safety achievement criteria are linked to the criteria used in the strategic planning. Periodic assessment of the safety situation using the proposed system ensures possibility to monitor current local safety conditions and assess the changes and the trends. A safe community assessment system is proposed to be used as a tool to unified municipalities safety comprehensiveness and compare safety level in

  10. Elaboration of Safe Community Assessment System

    Directory of Open Access Journals (Sweden)

    Algirdas Astrauskas

    2011-12-01

    Full Text Available The paper aims to design an assessment system to monitor and evaluate safety parameters and administrative efforts with the purpose to increase safety in municipalities. The safety monitoring system considered is to be the most important tool for creation anddevelopment of safe communities in Lithuania. Several methods were applied to achieve this purpose. In order to determine the role of local government in ensuring the safety of people, property and environment at the local level of a meta-analysis of research reports,the Lithuanian national legislation, strategic planning documents of the state and local government were carried out. Analysis of statistical data, structural analysis, comparative analysis and synthesis methods were used while investigating the areas of safety uncertainty, risk groups, identifying safety risk factors, determining their relationship, and creating a safe community assessment system.A safe community assessment system, which consists of two types of criteria, has been elaborated. The assessment system is based on the multi-level criteria for safety monitoring and the multi-level criteria for the evaluation of municipal activities in the field of building safety. Links between the criteria, peculiarities of their application and advantages in the process of safe community creation and development are analyzed.Design and implementation of the safe community assessment system is one of the most important stages to implement the idea of safe communities. The proposed system integrates a variety of risk areas, the safety achievement criteria are linked to the criteria used in thestrategic planning. Periodic assessment of the safety situation using the proposed system ensures possibility to monitor current local safety conditions and assess the changes and the trends. A safe community assessment system is proposed to be used as a tool to unified municipalities safety comprehensiveness and compare safety level in

  11. Safe use of nanomaterials

    CERN Multimedia

    2013-01-01

    The use of nanomaterials  is on the increase worldwide, including at CERN. The HSE Unit has established a safety guideline to inform you of the main requirements for the safe handling and disposal of nanomaterials at CERN.   A risk assessment tool has also been developed which guides the user through the process of evaluating the risk for his or her activity. Based on the calculated risk level, the tool provides a list of recommended control measures.   We would therefore like to draw your attention to: Safety Guideline C-0-0-5 - Safe handling and disposal of nanomaterials; and Safety Form C-0-0-2 - Nanomaterial Risk Assessment   You can consult all of CERN’s safety rules and guidelines here. Please contact the HSE Unit for any questions you may have.   The HSE Unit

  12. 25 CFR 700.55 - Decent, safe, and sanitary dwelling.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false Decent, safe, and sanitary dwelling. 700.55 Section 700... PROCEDURES General Policies and Instructions Definitions § 700.55 Decent, safe, and sanitary dwelling. (a) General. The term decent, safe, and sanitary dwelling means a dwelling which— (1) Meets applicable federal...

  13. Safe reading of chemical pathology reports: the RCPAQAP Report Assessment Survey.

    Science.gov (United States)

    Koetsier, Sabrina; Jones, Graham Ross Dallas; Badrick, Tony

    2016-06-01

    Pathology reports are a vital component of the request-test-report cycle communicating pathology results to doctors to support clinical decision making. This should be done in a comprehensive, safe and time-efficient manner. As doctors may receive reports from different laboratories these goals can be achieved more readily if reports are formatted in the same way. This study evaluates the formatting of paper reports produced by Australian laboratories for numerical biochemistry results. As part of the RCPAQAP Liquid Serum Chemistry program in 2015, laboratories were invited to supply a routine paper report displaying the results. A total of 37 reports were received for analysis. These reports were assessed for variation in a range of components and, where possible, against relevant Australian standards and guidelines. In summary, there was a wide variation in most of the report components assessed including test names, result alignment, result flagging, sequence of data elements on the page, date formatting and patient name formatting. In most components there was also variation from the Standards. In order to ensure safe result transmission by printed reports there is a need to promote the adoption of current reporting standards and monitor compliance with similar external quality assurance programs. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  14. The Acoustic and Peceptual Effects of Series and Parallel Processing

    Directory of Open Access Journals (Sweden)

    Melinda C. Anderson

    2009-01-01

    Full Text Available Temporal envelope (TE cues provide a great deal of speech information. This paper explores how spectral subtraction and dynamic-range compression gain modifications affect TE fluctuations for parallel and series configurations. In parallel processing, algorithms compute gains based on the same input signal, and the gains in dB are summed. In series processing, output from the first algorithm forms the input to the second algorithm. Acoustic measurements show that the parallel arrangement produces more gain fluctuations, introducing more changes to the TE than the series configurations. Intelligibility tests for normal-hearing (NH and hearing-impaired (HI listeners show (1 parallel processing gives significantly poorer speech understanding than an unprocessed (UNP signal and the series arrangement and (2 series processing and UNP yield similar results. Speech quality tests show that UNP is preferred to both parallel and series arrangements, although spectral subtraction is the most preferred. No significant differences exist in sound quality between the series and parallel arrangements, or between the NH group and the HI group. These results indicate that gain modifications affect intelligibility and sound quality differently. Listeners appear to have a higher tolerance for gain modifications with regard to intelligibility, while judgments for sound quality appear to be more affected by smaller amounts of gain modification.

  15. Transfer pricing and safe harbours

    Directory of Open Access Journals (Sweden)

    Veronika Solilová

    2013-01-01

    Full Text Available Transfer prices are significant for both taxpayers and tax administrations because they determine in large part taxable profits of associated enterprises in different tax jurisdictions. Moreover, in the context of taxation, transfer prices must be complied with the arm’s length principle. However, Multinational Enterprises have been faced daily by conflicting rules and approaches to applying the arm’s length principle, burdensome documentation requirements, inconsistent audit standards and unpredictable competent authority outcomes. Therefore, the Committee on Fiscal Affairs launched another project on the administrative aspects of transfer pricing in 2010. On 16 May 2013 as a partial solution of this project was approved by the OECD Council the Revised Section E on Safe Harbours in Chapter IV of the Transfer Pricing Guidelines for Multinational Enterprises and Tax Authorities. The paper is focused on significant changes of newly approved chapter IV of the Transfer Pricing Guidelines for Multinational Enterprises and Tax Authorities, further on analysis of practice in this area, on advantages and disadvantages of safe harbours for taxpayers and competent authorities with aim to suggest recommendations on use of safe harbours in the Czech Republic.

  16. Blood Test: Lead (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Test: Lead KidsHealth / For Parents / Blood Test: Lead What's ... español Análisis de sangre: plomo What Is a Blood Test? A blood test is when a sample of ...

  17. Inherently safe technologies-chemical and nuclear

    International Nuclear Information System (INIS)

    Weinberg, A.M.

    1984-01-01

    Probabilistic risk assessments show an inverse relationship between the likelihood and the consequences of nuclear and chemical plant accidents, but the Bhopal accident has change public complacency about the safety of chemical plants to such an extent that public confidence is now at the same low level as with nuclear plants. The nuclear industry's response was to strengthen its institutions and improve its technologies, but the public may not be convinced. One solution is to develop reactors which do not depend upon the active intervention of humans of electromechanical devices to deal with emergencies, but which have physical properties that limit the possible temperature and power of a reactor. The Process Inherent Ultimately Safe and the modular High-Temperature Gas-Cooled reactors are two possibilities. the chemical industry needs to develop its own inherently safe design precepts that incorporate smallness, safe processes, and hardening against sabotage. 5 references

  18. Intrinsically Safe and Economical Reactor (ISER)

    International Nuclear Information System (INIS)

    Wakabayashi, Hiroaki; Asahi, Yoshiro

    1991-01-01

    The Intrinsically Safe and Economical Reactor (ISER) is designed based on the principle of a process inherent ultimate safe reactor, PIUS, a so-called inherently safe reactor (ISR). ISER has been developed joingly by the members of the Kanagawa Institute of Technology, the University of Tokyo, the Japan Atomic Energy Research Institute (JAERI) and several industrial firms in Japan. This paper describes the requirements for the next generation of power reactor, the safety design philosphy of ISR and ISER, the controllability of ISER and the results of analyses of some of the design-based accidents (DBA) of ISER, namely station blackout, accidents in which the pressurizer relief valve becomes jammed and stuck in open position and tube breaks in the steam generator. It is concluded that the ISER can ensure a wide range of contraollabitily and fuel integrity for all the analysed DBAs. (orig.)

  19. Progress on PRISM, an inherently safe, economic, and testable advanced liquid metal reactor

    International Nuclear Information System (INIS)

    Tippets, F.E.; Salerno, L.N.; Boardman, C.E.; Kwant, W.; Murata, R.E.; Snyder, C.R.

    1987-01-01

    This paper reports progress on the design of PRISM (Power Reactor Inherently Safe Module) under the DOE-sponsored innovative reactor program now in its third year at General Electric. The purpose of this program is to develop a design for an inherently safe, reliable, and marketable liquid metal fast reactor power plant. The PRISM design approach includes the following key elements: Compact sodium-cooled pool-type reactor modules that are sized to enable factory fabrication, economical shipment to inland as well as water-side sites, and economical full-scale prototype testing for design certification; Nuclear safety-related envelope limited to the reactor modules and their service systems; Inherent, passive shutdown heat removal for loss-of-cooling events; Inherent, passive reactivity shutdown for failure-to-scram events

  20. Pseudo-random bit generator based on lag time series

    Science.gov (United States)

    García-Martínez, M.; Campos-Cantón, E.

    2014-12-01

    In this paper, we present a pseudo-random bit generator (PRBG) based on two lag time series of the logistic map using positive and negative values in the bifurcation parameter. In order to hidden the map used to build the pseudo-random series we have used a delay in the generation of time series. These new series when they are mapped xn against xn+1 present a cloud of points unrelated to the logistic map. Finally, the pseudo-random sequences have been tested with the suite of NIST giving satisfactory results for use in stream ciphers.

  1. Non-linear forecasting in high-frequency financial time series

    Science.gov (United States)

    Strozzi, F.; Zaldívar, J. M.

    2005-08-01

    A new methodology based on state space reconstruction techniques has been developed for trading in financial markets. The methodology has been tested using 18 high-frequency foreign exchange time series. The results are in apparent contradiction with the efficient market hypothesis which states that no profitable information about future movements can be obtained by studying the past prices series. In our (off-line) analysis positive gain may be obtained in all those series. The trading methodology is quite general and may be adapted to other financial time series. Finally, the steps for its on-line application are discussed.

  2. Regulations for the safe transport of radioactive material

    International Nuclear Information System (INIS)

    1995-01-01

    Regulations and rules for the safe transport of radioactive materials by all kinds of conveyance are offered. Different types of packages and the conditions associated with the methods of safe packaging are given

  3. WIPP waste package testing on simulated DHLW: emplacement

    International Nuclear Information System (INIS)

    Molecke, M.A.

    1984-01-01

    Several series of simulated (nonradioactive) defense high-level waste (DHLW) package tests have been emplaced in the WIPP, a research and development facility authorized to demonstrate the safe disposal of defense-related wastes. The primary purpose of these 3-to-7 year duration tests is to evaluate the in situ materials performance of waste package barriers (canisters, overpacks, backfills, and nonradioactive DHLW glass waste form) for possible future application to a licensed waste repository in salt. This paper describes all test materials, instrumentation, and emplacement and testing techniques, and discusses progress of the various tests. These tests are intended to provide information on materials behavior (i.e., corrosion, metallurgical and geochemical alterations, waste form durability, surface interactions, etc.), as well as comparison between several waste package designs, fabrications details, and actual costs. These experiments involve 18 full-size simulated DHLW packages (approximately 3.0 m x 0.6 m diameter) emplaced in vertical boreholes in the salt drift floor. Six of the test packages contain internal electrical heaters (470 W/canister), and were emplace under approximately reference DHLW repository conditions. Twelve other simulated DHLW packages were emplaced under accelerated-aging or overtest conditions, including the artificial introduction of brine, and a thermal loading approximately three to four times higher than reference. Eight of these 12 test packages contain 1500 W/canister electrical heaters; the other four are filled with DHLW glass. 9 refs., 1 fig

  4. Financial assistance to States and tribes to support emergency preparedness and response and the safe transportation of hazardous shipments

    International Nuclear Information System (INIS)

    Bradbury, J.A.; Jones, M.L.

    1995-01-01

    This report identifies and summarizes existing sources of financial assistance to States and Indian tribes in preparing and responding to transportation emergencies and ensuring the safe transportation of hazardous shipments through their jurisdictions. The report has been prepared as an information resource for the US Department of Energy's Office of Environmental Restoration and Waste Management, Office of Transportation, Emergency Management and Analytical Services. The report discusses funding programs administered by the following Federal agencies: Federal Emergency Management Agency; Department of Transportation; the Environmental Protection Agency; and the Department of Energy. Also included is a summary of fees assessed by some States on carriers of hazardous materials and hazardous waste. The discussion of programs is supplemented by an Appendix that provides a series of tables summarizing funding sources and amounts. The report includes several conclusions concerning the level of funding provided to Indian tribes, the relative ranking of funding sources and the variation among States in overall revenues for emergency response and safe transportation

  5. THE CONSEQUENCES OF GLOBALIZATION UPON SAFE TOURISM

    Directory of Open Access Journals (Sweden)

    Svetlana Mihić

    2009-11-01

    Full Text Available Globalization, a phenomenon on the rise, is characterized by the free cross-bor- der movement of individuals, technologies, and capital. It has far- reaching consequen- ces for tourism, too, as it implies travel for leisure and business, and correspondingly, financial transfers between various nation states. Startinf from the status quo in the field, the current paper sets out to analyze the consequences and implications of globalization upon safe tourism and conduct a marketing research into the perceptions of consumers upon Serbia as a safe vacation destination for the purpose of safe tourism. Finally the research results will be presented and several solutions will be provided for improving security in tourism zones

  6. Sun Safe Mode Controller Design for LADEE

    Science.gov (United States)

    Fusco, Jesse C.; Swei, Sean S. M.; Nakamura, Robert H.

    2015-01-01

    This paper presents the development of sun safe controllers which are designed to keep the spacecraft power positive and thermally balanced in the event an anomaly is detected. Employed by NASA's Lunar Atmosphere and Dust Environment Explorer (LADEE), the controllers utilize the measured sun vector and the spacecraft body rates for feedback control. To improve the accuracy of sun vector estimation, the least square minimization approach is applied to process the sensor data, which is proven to be effective and accurate. To validate the controllers, the LADEE spacecraft model engaging the sun safe mode was first simulated and then compared with the actual LADEE orbital fight data. The results demonstrated the applicability of the proposed sun safe controllers.

  7. Testing Homeopathy in Mouse Emotional Response Models: Pooled Data Analysis of Two Series of Studies

    Directory of Open Access Journals (Sweden)

    Paolo Bellavite

    2012-01-01

    Full Text Available Two previous investigations were performed to assess the activity of Gelsemium sempervirens (Gelsemium s. in mice, using emotional response models. These two series are pooled and analysed here. Gelsemium s. in various homeopathic centesimal dilutions/dynamizations (4C, 5C, 7C, 9C, and 30C, a placebo (solvent vehicle, and the reference drugs diazepam (1 mg/kg body weight or buspirone (5 mg/kg body weight were delivered intraperitoneally to groups of albino CD1 mice, and their effects on animal behaviour were assessed by the light-dark (LD choice test and the open-field (OF exploration test. Up to 14 separate replications were carried out in fully blind and randomised conditions. Pooled analysis demonstrated highly significant effects of Gelsemium s. 5C, 7C, and 30C on the OF parameter “time spent in central area” and of Gelsemium s. 5C, 9C, and 30C on the LD parameters “time spent in lit area” and “number of light-dark transitions,” without any sedative action or adverse effects on locomotion. This pooled data analysis confirms and reinforces the evidence that Gelsemium s. regulates emotional responses and behaviour of laboratory mice in a nonlinear fashion with dilution/dynamization.

  8. Conversion disorder in a neurological emergency department: Restrospective series

    Directory of Open Access Journals (Sweden)

    Alejandro Cardozo

    2017-01-01

    Full Text Available Objective: To observe the conversion disorder in a neurological emergency department. Methods: It is common that the initial approach to this patients include the use of various diagnostic exams. In this series we reviewed 94 patients that arrived a neurological emergency room in a 3 year period.Results: 72 patients were females (76%, and the initial presumptive diagnosis were: neurovascular syndrome in 36 patients (38.3%, convulsive disorder in 20 patients (21.28%, and conversive disorder in 8 patients (8.51%. 82 patients had motor symptoms and 61 sensitive symptoms. 88 patients (93% required neuroimaging studies, 77 (81% patients underwent through basic biochemical panels. Other tests performed were: electroencephalogram in 12 patients (12.77%, electromyography in 11 patients (11.7%, lumbar punction in 8 patients (8.04% and regarding the medical consult in the care of these patients 11 were evaluated by 1 specialists, 35 (37.2% by 2 different specialties, 42 (44.63% patients required evaluation by 3, and 6 patients (6.38% required evaluation by 4 different specialties.Conclusions: Based on this data, we conclude that conversion disorders require a lot of resources in the emergency room and that the similarities with neurological diseases demands a complete workup including expensive diagnostic tools. However, this patients can be discharged safely without requiring hospitalization.

  9. An Integrated Data-Driven Strategy for Safe-by-Design Nanoparticles: The FP7 MODERN Project.

    Science.gov (United States)

    Brehm, Martin; Kafka, Alexander; Bamler, Markus; Kühne, Ralph; Schüürmann, Gerrit; Sikk, Lauri; Burk, Jaanus; Burk, Peeter; Tamm, Tarmo; Tämm, Kaido; Pokhrel, Suman; Mädler, Lutz; Kahru, Anne; Aruoja, Villem; Sihtmäe, Mariliis; Scott-Fordsmand, Janeck; Sorensen, Peter B; Escorihuela, Laura; Roca, Carlos P; Fernández, Alberto; Giralt, Francesc; Rallo, Robert

    2017-01-01

    The development and implementation of safe-by-design strategies is key for the safe development of future generations of nanotechnology enabled products. The safety testing of the huge variety of nanomaterials that can be synthetized is unfeasible due to time and cost constraints. Computational modeling facilitates the implementation of alternative testing strategies in a time and cost effective way. The development of predictive nanotoxicology models requires the use of high quality experimental data on the structure, physicochemical properties and bioactivity of nanomaterials. The FP7 Project MODERN has developed and evaluated the main components of a computational framework for the evaluation of the environmental and health impacts of nanoparticles. This chapter describes each of the elements of the framework including aspects related to data generation, management and integration; development of nanodescriptors; establishment of nanostructure-activity relationships; identification of nanoparticle categories; hazard ranking and risk assessment.

  10. OR.NET: a service-oriented architecture for safe and dynamic medical device interoperability.

    Science.gov (United States)

    Kasparick, Martin; Schmitz, Malte; Andersen, Björn; Rockstroh, Max; Franke, Stefan; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2018-02-23

    Modern surgical departments are characterized by a high degree of automation supporting complex procedures. It recently became apparent that integrated operating rooms can improve the quality of care, simplify clinical workflows, and mitigate equipment-related incidents and human errors. Particularly using computer assistance based on data from integrated surgical devices is a promising opportunity. However, the lack of manufacturer-independent interoperability often prevents the deployment of collaborative assistive systems. The German flagship project OR.NET has therefore developed, implemented, validated, and standardized concepts for open medical device interoperability. This paper describes the universal OR.NET interoperability concept enabling a safe and dynamic manufacturer-independent interconnection of point-of-care (PoC) medical devices in the operating room and the whole clinic. It is based on a protocol specifically addressing the requirements of device-to-device communication, yet also provides solutions for connecting the clinical information technology (IT) infrastructure. We present the concept of a service-oriented medical device architecture (SOMDA) as well as an introduction to the technical specification implementing the SOMDA paradigm, currently being standardized within the IEEE 11073 service-oriented device connectivity (SDC) series. In addition, the Session concept is introduced as a key enabler for safe device interconnection in highly dynamic ensembles of networked medical devices; and finally, some security aspects of a SOMDA are discussed.

  11. Regulations for the safe transport of radioactive materials. 1973 revised edition (as amended).

    International Nuclear Information System (INIS)

    1979-01-01

    On the basis of a comprehensive review carried out by a panel of experts, a revised version of the International Atomic Energy Agency's Regulations for the Safe Transport of Radioactive Materials was approved by the Board of Governors in September 1972 and published in April 1973 as Safety Series No.6 - 1973 Revised Edition. Minor amendments, together with a number of changes of detail were promulgated by the Director General in 1975 and 1977. In October 1978, the Standing Advisory Group on the Safe Transport of Radioactive Materials, established by the Director General in 1977, reviewed and recommended a small number of additional amendments. The recommendations of SAGSTRAM were subsequently accepted by the Director General. All these minor amendments and changes of detail are incorporated in the present text of the Regulations. The purpose of these Regulations is to establish standards of safety which provide an acceptable level of control of the radiation hazards to persons, property and the environment that are associated with the transport of radioactive material. They apply to the transport by land, water or air, including transport on own account, of radioactive material other than that which is an integral part of the means of transport. Transport includes any operation incidental to the whole course of carriage, such as loading, unloading and storage in transit. The term includes both normal transport and that under accident conditions

  12. Homogenising time series: beliefs, dogmas and facts

    Science.gov (United States)

    Domonkos, P.

    2011-06-01

    In the recent decades various homogenisation methods have been developed, but the real effects of their application on time series are still not known sufficiently. The ongoing COST action HOME (COST ES0601) is devoted to reveal the real impacts of homogenisation methods more detailed and with higher confidence than earlier. As a part of the COST activity, a benchmark dataset was built whose characteristics approach well the characteristics of real networks of observed time series. This dataset offers much better opportunity than ever before to test the wide variety of homogenisation methods, and analyse the real effects of selected theoretical recommendations. Empirical results show that real observed time series usually include several inhomogeneities of different sizes. Small inhomogeneities often have similar statistical characteristics than natural changes caused by climatic variability, thus the pure application of the classic theory that change-points of observed time series can be found and corrected one-by-one is impossible. However, after homogenisation the linear trends, seasonal changes and long-term fluctuations of time series are usually much closer to the reality than in raw time series. Some problems around detecting multiple structures of inhomogeneities, as well as that of time series comparisons within homogenisation procedures are discussed briefly in the study.

  13. Influencing behaviour for safe working environments

    OpenAIRE

    Boer, de, J. (Johannes); Teeuw, W.B. (Wouter)

    2011-01-01

    Safety at work The objective of the project Safety at Work is to increase safety at the workplace by applying and combining state of the art artefacts from personal protective equipment and ambient intelligence technology. In this state of the art document we focus on the developments with respect to how (persuasive) technology can help to influence behaviour in a natural, automatic way in order to make industrial environments safer. We focus on personal safety, safe environments and safe beh...

  14. SensL B-Series and C-Series silicon photomultipliers for time-of-flight positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    O' Neill, K., E-mail: koneill@sensl.com; Jackson, C., E-mail: cjackson@sensl.com

    2015-07-01

    Silicon photomultipliers from SensL are designed for high performance, uniformity and low cost. They demonstrate peak photon detection efficiency of 41% at 420 nm, which is matched to the output spectrum of cerium doped lutetium orthosilicate. Coincidence resolving time of less than 220 ps is demonstrated. New process improvements have lead to the development of C-Series SiPM which reduces the dark noise by over an order of magnitude. In this paper we will show characterization test results which include photon detection efficiency, dark count rate, crosstalk probability, afterpulse probability and coincidence resolving time comparing B-Series to the newest pre-production C-Series. Additionally we will discuss the effect of silicon photomultiplier microcell size on coincidence resolving time allowing the optimal microcell size choice to be made for time of flight positron emission tomography systems.

  15. Now, It's Your Turn: How You Can Take Medicine Safely

    Science.gov (United States)

    ... turn Javascript on. Feature: Taking Medicines Safely Now, It's Your Turn: How You Can Take Medicine Safely ... medicine. The pharmacist has filled the prescription. Now it's up to you to take the medicine safely. ...

  16. Test plan for tank 241-C-104 retrieval testing

    International Nuclear Information System (INIS)

    HERTING, D.L.

    1999-01-01

    Tank 241-C-104 has been identified as one of the first tanks to be retrieved for high-level waste pretreatment and immobilization. Retrieval of the tank waste will require dilution. Laboratory tests are needed to determine the amount of dilution required for safe retrieval and transfer of feed. The proposed laboratory tests are described in this document

  17. Test Plan for Tank 241-C-104 Retrieval Testing

    International Nuclear Information System (INIS)

    HERTING, D.L.

    1999-01-01

    Tank 241-C-104 has been identified as one of the first tanks to be retrieved for high-level waste pretreatment and immobilization. Retrieval of the tank waste will require dilution. Laboratory tests are needed to determine the amount of dilution required for safe retrieval and transfer of feed. The proposed laboratory tests are described in this document

  18. Feasibility and safety of on table extubation after corrective surgical repair of tetralogy of Fallot in a developing country: A case series

    Directory of Open Access Journals (Sweden)

    Mohammad Irfan Akhtar

    2015-01-01

    Full Text Available Fast-track extubation is an established safe practice in pediatric congenital heart disease (CHD surgical patients. On table extubation (OTE in acyanotic CHD surgical patients is well established with validated safety profile. This practice is not yet reported in tetralogy of Fallot (TOF cardiac surgical repair patients in developing countries. Evidence suggests that TOF total correction patients should be extubated early, as positive pressure ventilation has a negative impact on right ventricular function and the overall increase in post-TOF repair complications such as low cardiac output state and arrhythmias. The objective of the case series was to determine the safety and feasibility of OTE in elective TOF total correction cardiac surgical patients with an integrated team approach. To the best of our knowledge, this is the first reported case series. A total of 8 elective male and female TOF patients were included. Standard anesthetic, surgical and perfusion techniques were used in these procedures. All patients were extubated in the operating room safely without any complications with the exception of one patient who continued to bleed for 3 h of postextubation at 2-3 ml/kg/h which was managed with transfusion of fresh frozen plasma at 15 mL/kg, packed red blood cells 10 mL/kg and bolus of transamine at 20 mg/kg. Apart from better surgical and bypass techniques, the most important factor leading to successful OTE was an excellent analgesia. On the basis of the case series, it is suggested to extubate selected TOF cardiac surgery repair patients on table safely with integrated multidisciplinary approach.

  19. Is nuclear power safe enough

    Energy Technology Data Exchange (ETDEWEB)

    Andresen, A F [Institutt for Atomenergi, Kjeller (Norway)

    1979-01-01

    The lecture formed a commentary on the report of the Norwegian Government's Commission on Nuclear power Safety which was published in October 1978. It was introductorily pointed out that 'safe' and 'safety' are not in themselves meaningful terms and that the probability of an occurrence is the real measure. The main items in the Commission's report have been core meltdown, releases during reprocessing, waste disposal, plutonium diversion and environmental impacts. The 21 members of the Commission were unanimous in 7 of the 8 chapters. In chapter 2, 'Summary and Conclusions', 3 members dissented from the majority opinion, that, subject to certain conditions, nuclear power was a safe and acceptable source of energy.

  20. The safe transport of radioactive materials

    CERN Document Server

    Gibson, R

    1966-01-01

    The Safe Transport of Radioactive Materials is a handbook that details the safety guidelines in transporting radioactive materials. The title covers the various regulations and policies, along with the safety measures and procedures of radioactive material transport. The text first details the 1963 version of the IAEA regulation for the safe transport of radioactive materials; the regulation covers the classification of radionuclides for transport purposes and the control of external radiation hazards during the transport of radioactive materials. The next chapter deals with concerns in the im

  1. Retrospective testing and case series study of porcine delta coronavirus in U.S. swine herds.

    Science.gov (United States)

    McCluskey, Brian J; Haley, Charles; Rovira, Albert; Main, Rodger; Zhang, Yan; Barder, Sunny

    2016-01-01

    Porcine deltacoronavirus (PDCoV) was first reported in the United States (US) in February 2014. This was the second novel swine enteric coronavirus detected in the US since May 2013. In this study, we conducted retrospective testing of samples submitted to three veterinary diagnostic laboratories where qualifying biological samples were derived from previously submitted diagnostic case submissions from US commercial swine farms with a clinical history of enteric disease or from cases that had been previously tested for transmissible gastroenteritis virus, PEDV, or rotavirus. Overall, 2286 banked samples were tested from 27 States. Samples were collected in 3 separate years and in 17 different months. Test results revealed 4 positive samples, 3 collected in August 2013 and 1 collected in October 2013. In addition, a case series including 42 operations in 10 States was conducted through administration of a survey. Survey data collected included information on characteristics of swine operations that had experienced PDCoV clinical signs. Special emphasis was placed on obtaining descriptive estimates of biosecurity practices and disease status over time of each operation. Clinical signs of PDCoV were reported to be similar to those of PEDV. The average number of animals on each operation exhibiting clinical signs (morbidity) and the average number of case fatalities was greatest for suckling and weaned pigs. Average operation-level weaned pig morbidity was greatest in the first week of the outbreak while average operation-level suckling pig case fatality was greatest in the second week of the outbreak. The survey included questions regarding biosecurity practices for visitors and operation employees; trucks, equipment and drivers; and feed sources. These questions attempted to identify a likely pathway of introduction of PDCoV onto the operations surveyed. Published by Elsevier B.V.

  2. Safe transport of radioactive materials - Leakage testing on packages. 1. ed.

    International Nuclear Information System (INIS)

    1996-01-01

    This International Standard describes a method for relating permissible activity release rates of the radioactive contents carried within a containment system to equivalent gas leakage rates under specified test conditions. This approach is called gas leakage test methodology. However, in this International Standard it is recognized that other methodologies might be acceptable. When other methodologies are to be used, it shall be shown that the methodology demonstrates that any release of the radioactive contents will not exceed the regulatory requirements. The use of any alternative methodology shall be by agreement with the competent authority. This International Standard provides both overall and detailed guidance on the complex relationships between an equivalent gas leakage test and a permissible activity release rate. Whereas the overall guidance is universally agreed upon, the use of the detailed guidance shall be agreed upon with the competent authority during the Type B package certification process. It should be noted that, for a given package, demonstration of compliance is not limited to a single methodology. While this International Standard does not require particular gas leakage test procedures, it does present minimum requirements for any test that is to be used. It is the responsibility of the package designer or consignor to estimate or determine the maximum permissible release rate of radioactivity to the environment and to select appropriate leakage test procedures that have adequate sensitivity. This International Standard pertains specifically to Type B packages for which the regulatory containment requirements are specified explicitly

  3. Environmental contact factors in eczema and the results of patch testing Chinese patients with a modified European standard series of allergens.

    Science.gov (United States)

    Li, Lin-Feng; Guo, Jing; Wang, Jing

    2004-07-01

    Environmental contact factors in eczema were investigated in China by clinical questionnaire and patch testing patients with a modified European standard series of allergens. 217 consecutive eczema patients were studied. Contact dermatitis (CD) was clinically diagnosed in 30% of the patients. Among the patients patch tested, 46 patients had clinically diagnosed allergic CD (ACD), 20 patients clinically had non-ACD (NACD) (including 16 cases of irritant contact dermatitis, 1 case of phototoxic contact reaction and 3 cases of asteatotic eczema) and 115 patients had clinically suspected ACD. 45 patients (98%) in the ACD group went on to have relevant patch test results. The most common ACD was from metals, fragrance materials, cosmetics and rubber materials. The most common contact allergens identified were nickel, fragrance mix, para-phenylenediamine (PPD), carba mix and thimerosal. No adverse reactions were observed to patch testing, except for pruritus in patch-test-positive patients. The positive rate of patch testing in ACD was much higher than that in NACD (98% versus 15%, P China.

  4. Combined SAFE/SNAP approach to safeguards evaluation

    International Nuclear Information System (INIS)

    Engi, D.; Chapman, L.D.; Grant, F.H.; Polito, J.

    1980-01-01

    Generally, the scope of a safeguards evaluation model can efficiently address one of two issues, (1) global safeguards effectiveness, or (2) vulnerability analysis for individual scenarios. The Safeguards Automated Facility Evaluation (SAFE) focuses on (1) while the Safeguards Network Analysis Procedure (SNAP) is directed at (2). SAFE addresses (1) in that it considers the entire facility, i.e., the composite system of hardware and human components, in one global analysis. SNAP addresses (2) by providing a safeguards modeling symbology sufficiently flexible to represent quite complex scenarios from the standpoint of hardware interfaces while also accounting for a rich variety of human decision making. A combined SAFE/SNAP approach to the problem of safeguards evaluation is described and illustrated through an example

  5. Parametric, nonparametric and parametric modelling of a chaotic circuit time series

    Science.gov (United States)

    Timmer, J.; Rust, H.; Horbelt, W.; Voss, H. U.

    2000-09-01

    The determination of a differential equation underlying a measured time series is a frequently arising task in nonlinear time series analysis. In the validation of a proposed model one often faces the dilemma that it is hard to decide whether possible discrepancies between the time series and model output are caused by an inappropriate model or by bad estimates of parameters in a correct type of model, or both. We propose a combination of parametric modelling based on Bock's multiple shooting algorithm and nonparametric modelling based on optimal transformations as a strategy to test proposed models and if rejected suggest and test new ones. We exemplify this strategy on an experimental time series from a chaotic circuit where we obtain an extremely accurate reconstruction of the observed attractor.

  6. BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES

    Energy Technology Data Exchange (ETDEWEB)

    Farquar, G; Leif, R

    2009-07-15

    Biocompatible polymers with hydrolyzable chemical bonds have been used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres were produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

  7. Development of Safe Food Handling Guidelines for Korean Consumers.

    Science.gov (United States)

    Kang, Hee-Jin; Lee, Min-Woo; Hwang, In-Kyeong; Kim, Jeong-Weon

    2015-08-01

    The purpose of this study was to develop guidelines for Korean consumers with regard to safe food handling practices at home by identifying current food handling issues. Korean consumers' behaviors regarding their safe food handling were identified via survey questionnaires that included items on individual hygiene practices, prepreparation steps when cooking, the cooking process, and the storage of leftover foods. The subjects were 417 Korean parents with elementary school children living in Seoul and Gyeonggi Province in the central area of Korea. The survey results revealed gaps between the knowledge or practices of Korean consumers and scientific evidence pertaining to safe food handling practices. Based on these findings, a leaflet on safe food handling guidelines was developed in accordance with Korean food culture. These guidelines suggest personal hygiene practices as well as fundamental principles and procedures for safe food handling from the stage of food purchase to that of keeping leftover dishes. A pilot application study with 50 consumers revealed that the guidelines effectively improved Korean consumers' safe food handling practices, suggesting that they can serve as practical educational material suitable for Korean consumers.

  8. Quantitative assessment of probability of failing safely for the safety instrumented system using reliability block diagram method

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Zhao, Shoutang; Hu, Bin

    2015-01-01

    Highlights: • Models of PFS for SIS were established by using the reliability block diagram. • The more accurate calculation of PFS for SIS can be acquired by using SL. • Degraded operation of complex SIS does not affect the availability of SIS. • The safe undetected failure is the largest contribution to the PFS of SIS. - Abstract: The spurious trip of safety instrumented system (SIS) brings great economic losses to production. How to ensure the safety instrumented system is reliable and available has been put on the schedule. But the existing models on spurious trip rate (STR) or probability of failing safely (PFS) are too simplified and not accurate, in-depth studies of availability to obtain more accurate PFS for SIS are required. Based on the analysis of factors that influence the PFS for the SIS, using reliability block diagram method (RBD), the quantitative study of PFS for the SIS is carried out, and gives some application examples. The results show that, the common cause failure will increase the PFS; degraded operation does not affect the availability of the SIS; if the equipment was tested and repaired one by one, the unavailability of the SIS can be ignored; the corresponding occurrence time of independent safe undetected failure should be the system lifecycle (SL) rather than the proof test interval and the independent safe undetected failure is the largest contribution to the PFS for the SIS

  9. Safe-haven CDS Premia

    DEFF Research Database (Denmark)

    Klingler, Sven; Lando, David

    We argue that Credit Default Swap (CDS) premia for safe-haven sovereigns, like Germany and the United States, are driven to a large extent by regulatory requirements under which derivatives dealing banks have an incentive to buy CDS to hedge counterparty credit risk of their counterparties. We...

  10. Video Nasoendoscopic-Assisted Transoral Adenoidectomy with the PEAK PlasmaBlade: A Preliminary Report of a Case Series

    Directory of Open Access Journals (Sweden)

    Chao-Yin Kuo

    2017-01-01

    Full Text Available Objectives. The primary objective for this study is to evaluate the advantages, disadvantages, surgical applicability, and outcome of the pulsed electron avalanche knife (PEAK PlasmaBlade in transoral adenoidectomy under direct visualization using video nasoendoscopy. Patients and Methods. In this series, six cases of adenoid hypertrophy showing varying clinical presentations in relation to its clinical course were surgically treated using a PEAK PlasmaBlade. Before and after surgery, all patients underwent nasal endoscopy to define the grading of hypertrophic adenoids and postoperative outcome. Pure tone audiometry and tympanometry tests were carried out to investigate the change in middle and inner ear functions. Results. The mean follow-up period was 23.8 months. Postoperatively, symptoms of otitis media with effusion were all relieved with closure of the air-bone gap (6/6. Other relevant ear complaints like tinnitus were resolved (1/1 and aural fullness disappeared in 87.5% of ears (7/8. Nasal obstruction (2/2 and postnasal drip (2/2 were improved after surgery. Conclusions. Based on this preliminary report of a case series in a limited sample size, we suggest that using the transoral PEAK PlasmaBlade for adenoidectomy guided by video nasoendoscopy is a safe and feasible surgical technique, allowing remarkable outcomes by providing precise tissue removal, effective hemostasis, and painless postoperative recovery.

  11. Two-phase flow experiments on Counter-Current Flow Limitation in a model of the hot leg of a pressurized water reactor (2015 test series)

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, Matthias; Lucas, Dirk; Pietruske, Heiko; Szalinski, Lutz

    2016-12-15

    Counter-Current Flow Limitation (CCFL) is of importance for PWR safety analyses in several accident scenarios connected with loss of coolant. Basing on the experiences obtained during a first series of hot leg tests now new experiments on counter-current flow limitation were conducted in the TOPFLOW pressure vessel. The test series comprises air-water tests at 1 and 2 bar as well as steam-water tests at 10, 25 and 50 bar. During the experiments the flow structure was observed along the hot leg model using a high-speed camera and web-cams. In addition pressure was measured at several positions along the horizontal part and the water levels in the reactor-simulator and steam-generator-simulator tanks were determined. This report documents the experimental setup including the description of operational and special measuring techniques, the experimental procedure and the data obtained. From these data flooding curves were obtained basing on the Wallis parameter. The results show a slight shift of the curves in dependency of the pressure. In addition a slight decrease of the slope was found with increasing pressure. Additional investigations concern the effects of hysteresis and the frequencies of liquid slugs. The latter ones show a dependency on pressure and the mass flow rate of the injected water. The data are available for CFD-model development and validation.

  12. Two-phase flow experiments on Counter-Current Flow Limitation in a model of the hot leg of a pressurized water reactor (2015 test series)

    International Nuclear Information System (INIS)

    Beyer, Matthias; Lucas, Dirk; Pietruske, Heiko; Szalinski, Lutz

    2016-12-01

    Counter-Current Flow Limitation (CCFL) is of importance for PWR safety analyses in several accident scenarios connected with loss of coolant. Basing on the experiences obtained during a first series of hot leg tests now new experiments on counter-current flow limitation were conducted in the TOPFLOW pressure vessel. The test series comprises air-water tests at 1 and 2 bar as well as steam-water tests at 10, 25 and 50 bar. During the experiments the flow structure was observed along the hot leg model using a high-speed camera and web-cams. In addition pressure was measured at several positions along the horizontal part and the water levels in the reactor-simulator and steam-generator-simulator tanks were determined. This report documents the experimental setup including the description of operational and special measuring techniques, the experimental procedure and the data obtained. From these data flooding curves were obtained basing on the Wallis parameter. The results show a slight shift of the curves in dependency of the pressure. In addition a slight decrease of the slope was found with increasing pressure. Additional investigations concern the effects of hysteresis and the frequencies of liquid slugs. The latter ones show a dependency on pressure and the mass flow rate of the injected water. The data are available for CFD-model development and validation.

  13. Americium/curium bushing melter drain tests

    International Nuclear Information System (INIS)

    Smith, M.E.; Hardy, B.J.; Smith, M.E.

    1997-01-01

    Americium and curium were produced in the past at the Savannah River Site (SRS) for research, medical, and radiological applications. They have been stored in a nitric acid solution in an SRS reprocessing facility for a number of years. Vitrification of the americium/curium (Am/Cm) solution will allow the material to be safely stored or transported to the DOE Oak Ridge Reservation. Oak Ridge is responsible for marketing radionuclides for research and medical applications. The bushing melter technology being used in the Am/Cm vitrification research work is also under consideration for the stabilization of other actinides such as neptunium and plutonium. A series of melter drain tests were conducted at the Savannah River Technology Center to determine the relationship between the drain tube assembly operating variables and the resulting pour initiation times, glass flowrates, drain tube temperatures, and stop pour times. Performance criteria such as ability to start and stop pours in a controlled manner were also evaluated. The tests were also intended to provide support of oil modeling of drain tube performance predictions and thermal modeling of the drain tube and drain tube heater assembly. These drain tests were instrumental in the design of subsequent melter drain tube and drain tube heaters for the Am/Cm bushing melter, and therefore in the success of the Am/Cm vitrification and plutonium immobilization programs

  14. A generalization of Bertrand's test

    Directory of Open Access Journals (Sweden)

    Amirali Tabatabai Adnani

    2014-07-01

    Full Text Available One of the most practical routine tests for convergence of a positive series makes use of the ratio test. If this test fails, we can use Rabbe's test. When Rabbe's test fails the next sharper criteria which may sometimes be used is the Bertrand's test. If this test fails,we can use a generalization of Bertrand's test and such tests can be continued in nitely. For simplicity, we call ratio test, Rabbe's test, Bertrand's test as the Bertrand's test of order 0, 1 and 2, respectively. In this paper, we generalize Bertrand's test in order k for natural k > 2. It is also shown that for any k, there exists a series such that the Bertrand's test of order fails, but such test of order k + 1 is useful, furthermore we show that there exists a series such that for any k, Bertrand's test of order k fails. The only prerequisite for reading this article is a standard knowledge of advanced calculus.

  15. Swimming Safely (A Cup of Health with CDC)

    Centers for Disease Control (CDC) Podcasts

    In the summertime, families will be flocking to pools for relaxation and relief from the heat. A few simple precautions can help ensure a safe day in the water. In this podcast, Michele Hlavsa discusses ways to stay safe at the pool.

  16. On Sums of Numerical Series and Fourier Series

    Science.gov (United States)

    Pavao, H. Germano; de Oliveira, E. Capelas

    2008-01-01

    We discuss a class of trigonometric functions whose corresponding Fourier series, on a conveniently chosen interval, can be used to calculate several numerical series. Particular cases are presented and two recent results involving numerical series are recovered. (Contains 1 note.)

  17. How safe are nuclear plants? How safe should they be?

    International Nuclear Information System (INIS)

    Kouts, H.

    1988-01-01

    It has become customary to think about safety of nuclear plants in terms of risk as defined by the WASH-1400 study that some of the implications for the non-specialist escape our attention. Yet it is known that a rational program to understand safety, to identify unsafe events, and to use this kind of information or analysis to improve safety, requires us to use the methods of quantitative risk assessment. How this process can be made more understandable to a broader group of nontechnical people and how can a wider acceptance of the results of the process be developed have been questions under study and are addressed in this report. These are questions that have been struggled with for some time in the world of nuclear plant safety. The Nuclear Regulatory Commission examined them for several years as it moved toward developing a position on safety goals for nuclear plants, a requirement that had been assigned it by Congress. Opinion was sought from a broad spectrum of individuals, within the field of nuclear power and outside it, on the topic that was popularly called, ''How safe is safe enough?'' Views were solicited on the answer to the question and also on the way the answer should be framed when it was adopted. This report discusses the public policy and its implementation

  18. Ergonomics: safe patient handling and mobility.

    Science.gov (United States)

    Hallmark, Beth; Mechan, Patricia; Shores, Lynne

    2015-03-01

    This article reviews and investigates the issues surrounding ergonomics, with a specific focus on safe patient handling and mobility. The health care worker of today faces many challenges, one of which is related to the safety of patients. Safe patient handling and mobility is on the forefront of the movement to improve patient safety. This article reviews the risks associated with patient handling and mobility, and informs the reader of current evidence-based practice relevant to this area of care. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Postirradiation examination data report for gap conductance test series. Test GC 2-1

    International Nuclear Information System (INIS)

    Murdock, B.A.

    1978-02-01

    The results of the postirradiation examination of four boiling water reactor type, zircaloy-clad, UO 2 -fueled rods tested in the Power Burst Facility are discussed. These rods were employed in Gap Conductance Test GC 2-1 which was performed to obtain experimental data from which test fuel rod gap conductance values could be determined by both the steady state ∫kdT and the power oscillation methods. The postirradiation examination results provided in the document will aid in interpreting the experimental data obtained during Test GC 2-1 and in evaluating the effect of fuel behavior on the fuel rod thermal response and interpreted gap conductances. Fuel rod fill gas composition and pressure are discussed. Measurements of fuel pellet-cladding gap and fuel crack areas are presented. The fuel structure is analyzed. Test rod instrumentation and power profiles are examined to better evaluate the test conditions

  20. Be-safe travel, a web-based geographic application to explore safe-route in an area

    Science.gov (United States)

    Utamima, Amalia; Djunaidy, Arif

    2017-08-01

    In large cities in developing countries, the various forms of criminality are often found. For instance, the most prominent crimes in Surabaya, Indonesia is 3C, that is theft with violence (curas), theft by weighting (curat), and motor vehicle theft (curanmor). 3C case most often occurs on the highway and residential areas. Therefore, new entrants in an area should be aware of these kind of crimes. Route Planners System or route planning system such as Google Maps only consider the shortest distance in the calculation of the optimal route. The selection of the optimal path in this study not only consider the shortest distance, but also involves other factors, namely the security level. This research considers at the need for an application to recommend the safest road to be passed by the vehicle passengers while drive an area. This research propose Be-Safe Travel, a web-based application using Google API that can be accessed by people who like to drive in an area, but still lack of knowledge of the pathways which are safe from crime. Be-Safe Travel is not only useful for the new entrants, but also useful for delivery courier of valuables goods to go through the safest streets.

  1. Infinite series

    CERN Document Server

    Hirschman, Isidore Isaac

    2014-01-01

    This text for advanced undergraduate and graduate students presents a rigorous approach that also emphasizes applications. Encompassing more than the usual amount of material on the problems of computation with series, the treatment offers many applications, including those related to the theory of special functions. Numerous problems appear throughout the book.The first chapter introduces the elementary theory of infinite series, followed by a relatively complete exposition of the basic properties of Taylor series and Fourier series. Additional subjects include series of functions and the app

  2. Full scaled tests of the KERENA trademark containment cooling condenser at the INKA test facility

    International Nuclear Information System (INIS)

    Leyer, Stephan; Maisberger, Fabian; Lineva, Natalia; Wagner, Thomas; Doll, Mathias; Herbst, Vasilli; Wich, Michael

    2010-01-01

    KERENA trademark is a medium-capacity boiling water reactor. It combines passive safety systems with active safety equipment of service-proven design. The passive systems utilize basic laws of physics, such as gravity and natural convection, enabling them to function without any power supply or actuation by instrumentation and control (I and C) equipment. They are designed to bring the plant to a safe and stable condition without the aid of active systems. Furthermore, the passive safety features partially replace the active systems, which reduces costs significantly and provides a safe, reliable and economically competitive plant design. At the new test facility at Karlstein called INKA (Integral Test Stand Karlstein), the key components of the KERENA trademark passive safety concept - the Emergency Condenser (EC), the Containment Cooling Condenser (CCC) and the passive core flooding system (PCFS) - are presently under full-scale testing,. Integral system tests will also be performed to show how the passive safety systems interact under various anticipated accident conditions and to demonstrate the ability of the passive systems to bring the plant to a safe and stable condition without the aid of active systems or actuation by I and C signals. The passive pressure pulse transmitter (PPPT) will be included in these integral tests. In this report the experimental setup and the first test results with the full scaled Containment Cooling Condenser will be described. (orig.)

  3. Modelling Changes in the Unconditional Variance of Long Stock Return Series

    DEFF Research Database (Denmark)

    Amado, Cristina; Teräsvirta, Timo

    In this paper we develop a testing and modelling procedure for describing the long-term volatility movements over very long return series. For the purpose, we assume that volatility is multiplicatively decomposed into a conditional and an unconditional component as in Amado and Teräsvirta (2011...... show that the long-memory property in volatility may be explained by ignored changes in the unconditional variance of the long series. Finally, based on a formal statistical test we find evidence of the superiority of volatility forecast accuracy of the new model over the GJR-GARCH model at all...... horizons for a subset of the long return series....

  4. Modelling changes in the unconditional variance of long stock return series

    DEFF Research Database (Denmark)

    Amado, Cristina; Teräsvirta, Timo

    2014-01-01

    In this paper we develop a testing and modelling procedure for describing the long-term volatility movements over very long daily return series. For this purpose we assume that volatility is multiplicatively decomposed into a conditional and an unconditional component as in Amado and Teräsvirta...... that the apparent long memory property in volatility may be interpreted as changes in the unconditional variance of the long series. Finally, based on a formal statistical test we find evidence of the superiority of volatility forecasting accuracy of the new model over the GJR-GARCH model at all horizons for eight...... subsets of the long return series....

  5. Safe handling of radiation sources

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    This chapter discussed the subjects related to the safe handling of radiation sources: type of radiation sources, method of use: transport within premises, transport outside premises; Disposal of Gamma Sources

  6. Strategies and challenges for safe injection practice in developing countries.

    Science.gov (United States)

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, P Ravi; Kumar, Kc Vikash

    2013-01-01

    Injection is one of the important health care procedures used globally to administer drugs. Its unsafe use can transmit various blood borne pathogens. This article aims to review the history and status of injection practices, its importance, interventions and the challenges for safe injection practice in developing countries. The history of injections started with the discovery of syringe in the early nineteenth century. Safe injection practice in developed countries was initiated in the early twentieth century but has not received adequate attention in developing countries. The establishment of "Safe Injection Global Network (SIGN)" was an milestone towards safe injection practice globally. In developing countries, people perceive injection as a powerful healing tool and do not hesitate to pay more for injections. Unsafe disposal and reuse of contaminated syringe is common. Ensuring safe injection practice is one of the greatest challenges for healthcare system in developing countries. To address the problem, interventions with active involvement of a number of stakeholders is essential. A combination of educational, managerial and regulatory strategies is found to be effective and economically viable. Rational and safe use of injections can save many lives but unsafe practice threatens life. Safe injection practice is crucial in developing countries. Evidence based interventions, with honest commitment and participation from the service provider, recipient and community with aid of policy makers are required to ensure safe injection practice.

  7. Effective and Safe Ships

    DEFF Research Database (Denmark)

    Pedersen, Preben Terndrup; Amdahl, Jørgen; Rutgersson, Olle

    1996-01-01

    A Joint Nordic Research project "Effecive and Safe Ships" is presented. The project is aiming to develop methods and tools for quantitative evaluation fo ship safety. This report is the report of the preliminary phase where the plan for the main project is developed. The objectives of the project...

  8. Local normalization: Uncovering correlations in non-stationary financial time series

    Science.gov (United States)

    Schäfer, Rudi; Guhr, Thomas

    2010-09-01

    The measurement of correlations between financial time series is of vital importance for risk management. In this paper we address an estimation error that stems from the non-stationarity of the time series. We put forward a method to rid the time series of local trends and variable volatility, while preserving cross-correlations. We test this method in a Monte Carlo simulation, and apply it to empirical data for the S&P 500 stocks.

  9. Flight Tests of a Remaining Flying Time Prediction System for Small Electric Aircraft in the Presence of Faults

    Science.gov (United States)

    Hogge, Edward F.; Kulkarni, Chetan S.; Vazquez, Sixto L.; Smalling, Kyle M.; Strom, Thomas H.; Hill, Boyd L.; Quach, Cuong C.

    2017-01-01

    This paper addresses the problem of building trust in the online prediction of a battery powered aircraft's remaining flying time. A series of flight tests is described that make use of a small electric powered unmanned aerial vehicle (eUAV) to verify the performance of the remaining flying time prediction algorithm. The estimate of remaining flying time is used to activate an alarm when the predicted remaining time is two minutes. This notifies the pilot to transition to the landing phase of the flight. A second alarm is activated when the battery charge falls below a specified limit threshold. This threshold is the point at which the battery energy reserve would no longer safely support two repeated aborted landing attempts. During the test series, the motor system is operated with the same predefined timed airspeed profile for each test. To test the robustness of the prediction, half of the tests were performed with, and half were performed without, a simulated powertrain fault. The pilot remotely engages a resistor bank at a specified time during the test flight to simulate a partial powertrain fault. The flying time prediction system is agnostic of the pilot's activation of the fault and must adapt to the vehicle's state. The time at which the limit threshold on battery charge is reached is then used to measure the accuracy of the remaining flying time predictions. Accuracy requirements for the alarms are considered and the results discussed.

  10. Analysis of Methods of Determining the Safe Ship Trajectory

    Directory of Open Access Journals (Sweden)

    Jozef Lisowski

    2016-07-01

    Full Text Available The paper describes six methods of optimal and game theory and artificial neural network for synthesis of safe control in collision situations at sea. The application of optimal and game control algorithms to determine the own ship safe trajectory during the passing of other encountered ships in good and restricted visibility at sea is presented. The comparison of the safe ship control in collision situation: multi-step matrix non-cooperative and cooperative games, multi-stage positional non-cooperative and cooperative games have been introduced. The considerations have been illustrated with examples of computer simulation of the algorithms to determine safe of own ship trajectories in a navigational situation during passing of eight met ships.

  11. A proposal to create an extension to the European baseline series.

    Science.gov (United States)

    Wilkinson, Mark; Gallo, Rosella; Goossens, An; Johansen, Jeanne D; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Schuttelaar, Marie L; Uter, Wolfgang

    2018-02-01

    The current European baseline series consists of 30 allergens, and was last updated in 2015. To use data from the European Surveillance System on Contact Allergies (ESSCA) to propose an extension to the European baseline series in response to changes in environmental exposures. Data from departmental and national extensions to the baseline series, together with some temporary additions from departments contributing to the ESSCA, were collated during 2013-2014. In total, 31689 patients were patch tested in 46 European departments. Many departments and national groups already consider the current European baseline series to be a suboptimal screen, and use their own extensions to it. The haptens tested are heterogeneous, although there are some consistent themes. Potential haptens to include in an extension to the European baseline series comprise sodium metabisulfite, formaldehyde-releasing preservatives, additional markers of fragrance allergy, propolis, Compositae mix, and 2-hydroxyethyl methacrylate. In combination with other published work from the ESSCA, changes to the current European baseline series are proposed for discussion. As well as addition of the allergens listed above, it is suggested that primin and clioquinol should be deleted from the series, owing to reduced environmental exposure. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Effect of Safe Water on Arsenicosis: A Follow-up Study.

    Science.gov (United States)

    Majumdar, Kunal K; Ghose, Aloke; Ghose, Nilima; Biswas, Anirban; Mazumder, D N Guha

    2014-04-01

    Arsenic pollution in groundwater, used for drinking purposes, has been envisaged as a problem of global concern. Treatment options for the management symptoms of chronic arsenicosis are limited. Mitigation option available for dealing with the health problem of ground water arsenic contamination rests mainly on supply of arsenic safe water in arsenic-endemic region of Indo-Bangladesh subcontinent. Limited information is available regarding the long-term effect of chronic arsenic toxicity after stoppage of consumption of arsenic-containing water. The current study was, therefore, done to assess, objectively, the effect of drinking arsenic safe water (water source in their houses were supplied with arsenic removal filters for getting arsenic-free water during the follow-up period. In participants belonging to Cohort-I, the skin score was found to improve significantly at the end of each year, and it was found to be reduced significantly from 2.17 ± 1.09 to 1.23 ± 1.17; P water on skin lesions. The systemic disease symptom score was also found to improve, but less significantly, at the end of 3 years in both the cohorts. Most important observation during the follow-up study was persistence of severe symptoms of chronic lung disease and severe skin lesion including Bowen's disease in spite of taking arsenic-safe water. Further, death could not be prevented to occur because of lung cancer and severe lung disease. It is, therefore, an urgent need to make arrangement for availability of safe water source among the arsenic-affected people in the district. Many of the people in the affected villages are not aware of contamination of their home tube wells with arsenic. Awareness generation and motivation of the people for testing their drinking water sources for arsenic and environmental interventions like rain water harvesting, ground water recharge, and restricting excessive use of ground water for domestic and agricultural purposes are also important to prevent further

  13. Safe2Tell® : an anonymous, 24/7 reporting system for preventing school violence.

    Science.gov (United States)

    Payne, Susan R T; Elliott, Delbert S

    2011-01-01

    There is widespread agreement that many school shootings could be prevented if authorities were informed that a student was planning or preparing to carry out an attack. A universal problem is that young people are highly reluctant to report on their peers. This code of silence represents a major barrier to prevention efforts. In response to the Columbine shooting, the state of Colorado established the Safe2Tell® anonymous, 24/7 reporting system for receiving and forwarding threats of violence, bullying, and other concerns. This article describes how the program has grown to the point that it now receives more than 100 calls per month. A series of case examples illustrates its success in responding to threatening situations, including twenty-eight potential school attacks. Copyright © 2011 Wiley Periodicals, Inc., A Wiley Company.

  14. On clustering fMRI time series

    DEFF Research Database (Denmark)

    Goutte, Cyril; Toft, Peter Aundal; Rostrup, E.

    1999-01-01

    Analysis of fMRI time series is often performed by extracting one or more parameters for the individual voxels. Methods based, e.g., on various statistical tests are then used to yield parameters corresponding to probability of activation or activation strength. However, these methods do...

  15. Local Safety Toolkit: Enabling safe communities of opportunity

    CSIR Research Space (South Africa)

    Holtmann, B

    2010-08-31

    Full Text Available remain inadequate to achieve safety. The Local Safety Toolkit supports a strategy for a Safe South Africa through the implementation of a model for a Safe Community of Opportunity. The model is the outcome of work undertaken over the course of the past...

  16. Measurements of spatial population synchrony: influence of time series transformations.

    Science.gov (United States)

    Chevalier, Mathieu; Laffaille, Pascal; Ferdy, Jean-Baptiste; Grenouillet, Gaël

    2015-09-01

    Two mechanisms have been proposed to explain spatial population synchrony: dispersal among populations, and the spatial correlation of density-independent factors (the "Moran effect"). To identify which of these two mechanisms is driving spatial population synchrony, time series transformations (TSTs) of abundance data have been used to remove the signature of one mechanism, and highlight the effect of the other. However, several issues with TSTs remain, and to date no consensus has emerged about how population time series should be handled in synchrony studies. Here, by using 3131 time series involving 34 fish species found in French rivers, we computed several metrics commonly used in synchrony studies to determine whether a large-scale climatic factor (temperature) influenced fish population dynamics at the regional scale, and to test the effect of three commonly used TSTs (detrending, prewhitening and a combination of both) on these metrics. We also tested whether the influence of TSTs on time series and population synchrony levels was related to the features of the time series using both empirical and simulated time series. For several species, and regardless of the TST used, we evidenced a Moran effect on freshwater fish populations. However, these results were globally biased downward by TSTs which reduced our ability to detect significant signals. Depending on the species and the features of the time series, we found that TSTs could lead to contradictory results, regardless of the metric considered. Finally, we suggest guidelines on how population time series should be processed in synchrony studies.

  17. Water hydraulic manipulator for fail safe and fault tolerant remote handling operations at ITER

    International Nuclear Information System (INIS)

    Nieminen, Peetu; Esque, Salvador; Muhammad, Ali; Mattila, Jouni; Vaeyrynen, Jukka; Siuko, Mikko; Vilenius, Matti

    2009-01-01

    Department of Intelligent Hydraulics and Automation (IHA) of Tampere University of Technology has been involved in the European Fusion program since 1994 within the ITER reactor maintenance activities. In this paper we discuss the design and development of a six degrees of freedom water hydraulic manipulator with a force feedback for teleoperation tasks. The manipulator is planned to be delivered to Divertor Test Platform 2 (DTP2) during year 2008. The paper also discusses the possibility to improve the fail safe and redundant operation of the manipulator. During the design of the water hydraulic manipulator, special provisions have been made in order to meet the safety requirements such as servo valve block for redundant operation and safety vane brakes for fail safe operation.

  18. Are EU Banks Safe?

    NARCIS (Netherlands)

    R.J. Theissen (Roel)

    2013-01-01

    markdownabstract__Abstract__ What exactly are the rules banks are subject to, and are they fit for purpose? These are the two questions addressed in this book ‘Are EU banks safe?’ and its descriptive companion book ‘EU banking supervision’. The full rulebook on banks is difficult to find

  19. Combined SAFE/SNAP approach to safeguards evaluation

    International Nuclear Information System (INIS)

    Engi, D.; Chapman, L.D.; Grant, F.H.; Polito, J.

    1980-01-01

    The scope of a safeguards evaluation model can efficiently address one of two issues: (1) global safeguards effectiveness or (2) vulnerability analysis for individual scenarios. The Safeguards Automated Facility Evaluation (SAFE) focuses on the first issue, while the Safeguards Network Analysis Procedure (SNAP) is directed towards the second. A combined SAFE/SNAP approach to the problem of safeguards evaluation is described and illustrated through an example. 4 refs

  20. High-resolution electron spectroscopy of the 1s23lnl' Be-like series in oxygen and neon. Test of theoretical data: I. Experimental method and theoretical background

    International Nuclear Information System (INIS)

    Bordenave-Montesquieu, A; Moretto-Capelle, P; Bordenave-Montesquieu, D

    2003-01-01

    A complete and accurate experimental test of theoretical spectroscopic data sets (state positions, lifetimes) available for the n = 3-5 terms of the 1s 2 3lnl' Rydberg series of oxygen and neon ions is presented in a series of two papers. This result was achieved by fitting our high resolution electron spectra with post-collisional lineshapes calculated with the help of these spectroscopic data. In this paper the method which has been developed for this fitting procedure is explained. In addition, as a first test, a comparison of all the available calculated spectroscopic data is presented and discussed. Strong deviations of transition energies and decay lifetimes are observed in many cases. Best data are selected in the following companion paper through a quantitative comparison with our experimental electron spectra

  1. A Privacy Analysis of Google and Yandex Safe Browsing

    OpenAIRE

    Gerbet , Thomas; Kumar , Amrit; Lauradoux , Cédric

    2015-01-01

    Google and Yandex Safe Browsing are popular services included in many webbrowsers to prevent users from visiting phishing or malware website links. If Safe Browsing servicesprotect their users from losing private information, they also require that their servers receivebrowsing information on the very same users. In this paper, we present an analysis of Googleand Yandex Safe Browsing services from a privacy perspective. We quantify the privacy providedby these services by analyzing the possib...

  2. DHS small-scale safety and thermal testing of improvised explosives-comparison of testing performance

    International Nuclear Information System (INIS)

    Reynolds, J G; Hsu, P C; Sandstrom, M M; Brown, G W; Warner, K F; Phillips, J J; Shelley, T J; Reyes, J A

    2014-01-01

    One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or homemade explosives (HMEs) to SSST testing, 16 HME materials were compared to three standard military explosives in a proficiency-type round robin study among five laboratories-two DoD and three DOE-sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials-powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. More than 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for developing safe handling and storage practices. This paper presents a generalized comparison of the results among the testing participants, comparison of friction results from BAM (German Bundesanstalt für Materi-alprüfung) and ABL (Allegany Ballistics Laboratory) designed testing equipment, and an overview of the statistical results from the RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) standard tested throughout the proficiency test.

  3. FLECHT low flooding rate cosine test series data report

    International Nuclear Information System (INIS)

    Rosal, E.R.; Hochreiter, L.E.; McGuire, M.F.; Krepinevich, M.C.

    1975-12-01

    The FLECHT Low Flooding Rate Tests were conducted in an improved original FLECHT Test Facility to provide heat transfer coefficient and entrainment data at forced flooding rates of 1 in./sec and below. In addition these tests were performed to supplement parametric effects studied in the original FLECHT program, provide data for reflood model development, repeat original FLECHT tests with new instrumentation and data processing techniques, and to provide data to establish test repeatability. These tests examined the effects of low initial clad temperature, variable stepped and continuously variable flooding rates, housing heat release, run peak power, constant low flooding rates, coolant subcooling, hot and cold channel entrainment, and bundle stored and generated power. Data obtained in sixty four runs which met the test specifications are reported, and include rod clad temperatures, turn around and quench times, heat transfer coefficients, inlet flooding rates, overall mass balances, differential pressures and calculated void fractions in the test section, thimble wall and steam temperatures, exhaust steam and liquid carryover rates, and housing total and rate of heat release

  4. Challenging stereotypes? The older woman in the TV series Brothers & Sisters.

    Science.gov (United States)

    Oró-Piqueras, Maricel

    2014-12-01

    The TV series, Brothers & Sisters, broadcast from 2006 to 2011 by ABC (USA) and a year later by Channel 4 (UK) with quite high audience rates, starts when the patriarchal figure, William Walker, dies of a heart attack and two female figures around their sixties come center stage: his wife, Nora Walker, and his long-term lover, Holly Harper. Once the patriarchal figure disappears, the female characters regain visibility by entering the labor market and starting relationships with other men. In that sense, both protagonists experience aging as a time in which they are increasingly freed from social and family constraints. However, their roles as nurturers keep on bringing them back to the domestic space in which they are safe from being involved in uncomfortable and unsuitable situations. Drawing on previous studies on the representation of the older woman in fictional media, this article intends to discern to what extent stereotypes related to the older woman are challenged through the two main protagonists of a contemporary TV series. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Wind Speed Prediction with Wavelet Time Series Based on Lorenz Disturbance

    Directory of Open Access Journals (Sweden)

    ZHANG, Y.

    2017-08-01

    Full Text Available Due to the sustainable and pollution-free characteristics, wind energy has been one of the fastest growing renewable energy sources. However, the intermittent and random fluctuation of wind speed presents many challenges for reliable wind power integration and normal operation of wind farm. Accurate wind speed prediction is the key to ensure the safe operation of power system and to develop wind energy resources. Therefore, this paper has presented a wavelet time series wind speed prediction model based on Lorenz disturbance. Therefore, in this paper, combined with the atmospheric dynamical system, a wavelet-time series improved wind speed prediction model based on Lorenz disturbance is proposed and the wind turbines of different climate types in Spain and China are used to simulate the disturbances of Lorenz equations with different initial values. The prediction results show that the improved model can effectively correct the preliminary prediction of wind speed, improving the prediction. In a word, the research work in this paper will be helpful to arrange the electric power dispatching plan and ensure the normal operation of the wind farm.

  6. Training in radiation protection and the safe use of radiation sources

    International Nuclear Information System (INIS)

    2001-01-01

    Series No. 280: Training Courses on Radiation Protection, was published in 1988. This revision takes account of the many developments in radiation protection and the safe use of radiation sources and in training methods of recent years. As well as the requirements on training established by the BSS, it also relates to the Safety Guide on Building Competence in Radiation Protection and the Safe Use of Radiation Sources

  7. Safe transport of radioactive material. 3. ed

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-12-01

    The IAEA has developed a standardized approach to transport safety training as a means of helping Member States to implement the Transport Regulations. The training manual is an anchor of this standardized approach to training: it contains all the topics presented in the sequential order recommended by the IAEA for the student to gain a thorough understanding of the body of knowledge that is needed to ensure that radioactive material ranked as Class 7 in the United Nations' nomenclature for dangerous goods - is transported safely. The explanations in the text refer, where needed, to the appropriate requirements in the IAEA's Transport Regulations; additional useful information is also provided. Thus, the training manual in addition to the Transport Regulations and their supporting documents is used by the IAEA as the basis for delivering all of its training courses on the safe transport of radioactive material. Enclosed with the training manual is a CD-ROM that contains the text of the manual as well as the visual aids that are used at the IAEA's training courses. The following topics are covered: review of radioactivity and radiation; review of radiation protection principles; regulatory terminology; basic safety concepts: materials and packages; activity limits and material restrictions; selection of optimal package type; test procedures: material and packages; requirements for transport; control of material in transport; fissile material: regulatory requirements and operational aspects; quality assurance; national competent authority; additional regulatory constraints for transport; international liability and insurance; emergency planning and preparedness; training; services provided by the IAEA.

  8. Safe transport of radioactive material. 3. ed

    International Nuclear Information System (INIS)

    2002-01-01

    The IAEA has developed a standardized approach to transport safety training as a means of helping Member States to implement the Transport Regulations. The training manual is an anchor of this standardized approach to training: it contains all the topics presented in the sequential order recommended by the IAEA for the student to gain a thorough understanding of the body of knowledge that is needed to ensure that radioactive material ranked as Class 7 in the United Nations' nomenclature for dangerous goods - is transported safely. The explanations in the text refer, where needed, to the appropriate requirements in the IAEA's Transport Regulations; additional useful information is also provided. Thus, the training manual in addition to the Transport Regulations and their supporting documents is used by the IAEA as the basis for delivering all of its training courses on the safe transport of radioactive material. Enclosed with the training manual is a CD-ROM that contains the text of the manual as well as the visual aids that are used at the IAEA's training courses. The following topics are covered: review of radioactivity and radiation; review of radiation protection principles; regulatory terminology; basic safety concepts: materials and packages; activity limits and material restrictions; selection of optimal package type; test procedures: material and packages; requirements for transport; control of material in transport; fissile material: regulatory requirements and operational aspects; quality assurance; national competent authority; additional regulatory constraints for transport; international liability and insurance; emergency planning and preparedness; training; services provided by the IAEA

  9. Making Big Data, Safe Data: A Test Optimization Approach

    Science.gov (United States)

    2016-06-15

    catalyzed by the need to put a value on testing. Included with this project report is a proof of concept created in MS Excel utilizing its VBA ...Language To make the proof of concept more user friendly, MS Excel was chosen for its convenient user interface and its developer tool, VBA . Another...reason it was selected is everyone has easy access to MS Excel, so the file accompanying this project paper can be easily viewed, used, and modified by

  10. Prospective validation of criteria, including age, for safe, nonsurgical management of the ruptured spleen

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J.S. Jr.; Wengrovitz, M.A.; DeLong, B.S. (Pennsylvania State University College of Medicine, Hershey (United States))

    1992-09-01

    One hundred twelve cases of blunt splenic rupture were prospectively entered (October 1987-October 1991) into surgical or nonsurgical management groups using these criteria for the nonsurgical group: hemodynamic stability-age less than 55 years-CT scan appearance of grade I, II, or III injury-absence of concomitant injuries precluding abdominal assessment+absence of other documented abdominal injuries. All ages were included and AAST injury scaling was used. Patients were grouped from the trauma room. The surgical treatment group included 66 patients (49 splenectomies, 17 splenorraphies). These patients were generally older and more severely injured, required more transfused blood, and a longer ICU stay. The nonsurgical group included 46 patients with 33 older than 14 years. There were 3 patients over the age of 55 years inappropriately included in this group, and nonsurgical therapy failed in all three. Statistical analysis (chi 2) showed that more splenic injuries were observed and more spleens were saved with these criteria applied prospectively compared with a previous retrospective series in the same institution. The series had a success rate of 93%, and validates the criteria used for safe, nonsurgical management of the ruptured spleen and adds a new criterion: a maximum age of 55 years.

  11. Prospective validation of criteria, including age, for safe, nonsurgical management of the ruptured spleen

    International Nuclear Information System (INIS)

    Smith, J.S. Jr.; Wengrovitz, M.A.; DeLong, B.S.

    1992-01-01

    One hundred twelve cases of blunt splenic rupture were prospectively entered (October 1987-October 1991) into surgical or nonsurgical management groups using these criteria for the nonsurgical group: hemodynamic stability-age less than 55 years-CT scan appearance of grade I, II, or III injury-absence of concomitant injuries precluding abdominal assessment+absence of other documented abdominal injuries. All ages were included and AAST injury scaling was used. Patients were grouped from the trauma room. The surgical treatment group included 66 patients (49 splenectomies, 17 splenorraphies). These patients were generally older and more severely injured, required more transfused blood, and a longer ICU stay. The nonsurgical group included 46 patients with 33 older than 14 years. There were 3 patients over the age of 55 years inappropriately included in this group, and nonsurgical therapy failed in all three. Statistical analysis (chi 2) showed that more splenic injuries were observed and more spleens were saved with these criteria applied prospectively compared with a previous retrospective series in the same institution. The series had a success rate of 93%, and validates the criteria used for safe, nonsurgical management of the ruptured spleen and adds a new criterion: a maximum age of 55 years

  12. On the analytic continuation of functions defined by Legendre series

    International Nuclear Information System (INIS)

    Grinstein, F.F.

    1981-07-01

    An infinite diagonal sequence of Punctual Pade Approximants is considered for the approximate analytical continuation of a function defined by a formal Legendre series. The technique is tested in the case of two series with exactly known analytical sum: the generating function for Legendre polynomials and the Coulombian scattering amplitude. (author)

  13. Correction factors for safe performance of API X65 pipeline steel

    International Nuclear Information System (INIS)

    Hashemi, Sayyed H.

    2009-01-01

    Prediction of required Charpy energy for fracture arrest is vital for safe performance of gas transportation pipelines. This is commonly estimated through failure models calibrated in the past on fracture data from combined Charpy tests and full-thickness burst experiments. Unfortunately, such pipeline failure models are unable to correctly predict the minimum arrest toughness of thermo-mechanical controlled rolled (TMCR) steels. To refine the existing failure models, different empirical adjustments have been proposed in recent years. In this paper, similar correction factors were derived from fracture information of instrumented Charpy impact tests on API X65 steel. The contribution of different fracture mechanisms of impact test specimens was determined through energy partitioning analysis. Parts of the energy contribution were correlated then to the source of uncertainty observed in similar experiments. The applied technique was similar to that of previous studies on X70 and X100 steels, and proved to be encouraging in giving consistent results compared to available test data.

  14. Alcohol use and safe drinking

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001944.htm Alcohol use and safe drinking To use the sharing features on this page, please enable JavaScript. Alcohol use involves drinking beer, wine, or hard liquor. ...

  15. Dukovany NPP - Safely 16 TERA

    International Nuclear Information System (INIS)

    Vlcek, J.

    2008-01-01

    In this presentation increasing of power output of the Dukovany NPP is reviewed. To operate all Dukovany Units safely with the perspective of long-term operation (LTO) of 50 - 60 years it is proposed.

  16. Setting priorities for safe motherhood interventions in resource-scarce settings.

    Science.gov (United States)

    Prata, Ndola; Sreenivas, Amita; Greig, Fiona; Walsh, Julia; Potts, Malcolm

    2010-01-01

    Guide policy-makers in prioritizing safe motherhood interventions. Three models (LOW, MED, HIGH) were constructed based on 34 sub-Saharan African countries to assess the relative cost-effectiveness of available safe motherhood interventions. Cost and effectiveness data were compiled and inserted into the WHO Mother Baby Package Costing Spreadsheet. For each model we assessed the percentage in maternal mortality reduction after implementing all interventions, and optimal combinations of interventions given restricted budgets of US$ 0.50, US$ 1.00, US$ 1.50 per capital maternal health expenditures respectively for LOW, MED, and HIGH models. The most cost-effective interventions were family planning and safe abortion (fpsa), antenatal care including misoprostol distribution for postpartum hemorrhage prevention at home deliveries (anc-miso), followed by sepsis treatment (sepsis) and facility-based postpartum hemorrhage management (pph). The combination of interventions that avert the greatest number of maternal deaths should be prioritized and expanded to cover the greatest number of women at risk. Those which save the most number of lives in each model are 'fpsa, anc-miso' and 'fpsa, sepsis, safe delivery' for LOW; 'fpsa, anc-miso' and 'fpsa, sepsis, safe delivery' for MED; and 'fpsa, anc-miso, sepsis, eclampsia treatment, safe delivery' for HIGH settings. Safe motherhood interventions save a significant number of newborn lives.

  17. Power Burst Facility Severe Fuel Damage test series

    International Nuclear Information System (INIS)

    Buescher, B.J.; Osetek, D.J.; Ploger, S.A.

    1982-01-01

    The Severe Fuel Damage (SFD) tests planned for the Power Burst Facility (PBF) are described. Bundles containing 32 zircaloy-clad, PWR-type fuel rods will be subjected to severe overheating transients in a high-pressure, superheated-steam environment. Cladding temperatures are expected to reach 2400 0 K, resulting in cladding ballooning and rupture, severe cladding oxidation, cladding melting, fuel dissolution, fuel rod fragmentation, and possibly, rubble bed formation. An experiment effluent collection system is being installed and the PBF fission product monitoring system is being upgraded to meet the special requirements of the SFD tests. Scoping calculations were performed to evaluate performance of the SFD test design and to establish operational requirements for the PBF loop

  18. A study on characterization and evaluation methodologies of radioactive waste forms for safe disposal

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Y. C.; Lee, G. S.; Kim, G. J.; Nam, H.; Seok, J. H. [Yonsei Univ., Seoul (Korea, Republic of)

    2004-02-15

    The contents and scope of the study are summarized as follows : elicitation of significant items for characteristic assessment about stability analysis of radioactive waste forms for safe disposal, compressive strength, free water, leaching rate, and weatherability. Suggestion of assessment methods through the characteristic test of waste forms, comparison of assessment methods and suggestion of suitable testing methods about the above stated 4 items. Assessment modeling development for long-term stability of radioactive waste forms, weatherometric test of waste forms, expectation modeling development through VOM(Valance-Oxygen Model). Suggestion of determination standard together assessment testing methods and description about the standard. Explanation to be suitable guideline and regulation of waste handling and acceptance.

  19. Advisory material for the IAEA Regulations for the safe transport of radioactive material (1985 Edition). 3. ed.

    International Nuclear Information System (INIS)

    1987-01-01

    The purpose of this document is to provide advice on the application of the provisions of the 1985 Edition of Safety Series No. 6 (concerning the IAEA Regulations for the Safe Transport of Radioactive Material) in order to help achieve compliance with the regulatory standards. This document also reflects the corrections and changes implemented by the 1986 Supplement to the Regulations for the Safe Transport of Radioactive Material. Its intent is to describe methods, techniques and practices (citing any appropriate national and international standards) which can be considered a means of satisfying certain requirements. It should always be read as offering 'a way' or 'ways' rather than 'the unique way' of achieving compliance. The information provided is to be considered purely advisory and never mandatory, except where a competent authority may require use of any part or parts of the text. This document provides information about the technical requirements of the Regulations and about the methods and technology which may be employed to satisfy them, for the benefit of designers and manufacturers of packagings, consignors, carriers, competent authorities and others, i.e. it provides 'how' information

  20. How safe is safe?

    International Nuclear Information System (INIS)

    Hughes, C.F.; Flood, M.

    1996-01-01

    60 and 70 degree convexo-concave valve. Nine hundred and one valves were implanted in Australia. Twelve strut fractures were reported. Two other patients have been explanted and have demonstrated 'single leg separation'. This particular problem was only investigated when two patients died of a fractured valve in the same hospital on the same day. A retrospective study of all known patients in Australia has shown poor follow up, lack of knowledge and indeed lack of interest in device failure modes. Consequently, the Australian and New Zealand Heart Valve Registry was established to track all implanted valves and to notify physicians of any new information. This is perhaps the first device-specific register in Australia. The safety of individual devices is often not known by manufacturers, regulators and clinicians alike. No follow up is available and large volume long term studies are yet to be implemented for the majority of devices. Without such studies and without mandatory problem reporting, the relative safety of medical devices will continue to be measured by banner headlines, sensational TV 'grabs' and protracted law suits. At present, only schemes such as the Problem Reporting Scheme can tell us (albeit vaguely) 'how safe is safe'