WorldWideScience

Sample records for safe ground check

  1. 30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.

    Science.gov (United States)

    2010-07-01

    ... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance grounded systems. [Statutory Provisions] On and after September 30, 1970, high-voltage, resistance grounded systems... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage...

  2. 30 CFR 77.902-1 - Fail safe ground check circuits; maximum voltage.

    Science.gov (United States)

    2010-07-01

    ... voltage. 77.902-1 Section 77.902-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.902-1 Fail safe ground check circuits; maximum voltage. The maximum voltage used for ground check circuits under § 77.902...

  3. 30 CFR 77.803-1 - Fail safe ground check circuits; maximum voltage.

    Science.gov (United States)

    2010-07-01

    ... voltage. 77.803-1 Section 77.803-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.803-1 Fail safe ground check circuits; maximum voltage. The maximum voltage used for ground check circuits under § 77.803 shall not...

  4. 30 CFR 77.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.

    Science.gov (United States)

    2010-07-01

    ... circuits on high-voltage resistance grounded systems. On and after September 30, 1971, all high-voltage... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage resistance grounded systems. 77.803 Section 77.803 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION...

  5. 30 CFR 77.902 - Low- and medium-voltage ground check monitor circuits.

    Science.gov (United States)

    2010-07-01

    ... medium-voltage resistance grounded systems to portable and mobile equipment shall include a fail safe... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low- and medium-voltage ground check monitor... OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.902 Low- and...

  6. 30 CFR 75.902 - Low- and medium-voltage ground check monitor circuits.

    Science.gov (United States)

    2010-07-01

    ... Medium-Voltage Alternating Current Circuits § 75.902 Low- and medium-voltage ground check monitor circuits. [Statutory Provisions] On or before September 30, 1970, low- and medium-voltage resistance... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Low- and medium-voltage ground check monitor...

  7. Embracing Safe Ground Test Facility Operations and Maintenance

    Science.gov (United States)

    Dunn, Steven C.; Green, Donald R.

    2010-01-01

    Conducting integrated operations and maintenance in wind tunnel ground test facilities requires a balance of meeting due dates, efficient operation, responsiveness to the test customer, data quality, effective maintenance (relating to readiness and reliability), and personnel and facility safety. Safety is non-negotiable, so the balance must be an "and" with other requirements and needs. Pressure to deliver services faster at increasing levels of quality in under-maintained facilities is typical. A challenge for management is to balance the "need for speed" with safety and quality. It s especially important to communicate this balance across the organization - workers, with a desire to perform, can be tempted to cut corners on defined processes to increase speed. Having a lean staff can extend the time required for pre-test preparations, so providing a safe work environment for facility personnel and providing good stewardship for expensive National capabilities can be put at risk by one well-intending person using at-risk behavior. This paper documents a specific, though typical, operational environment and cites management and worker safety initiatives and tools used to provide a safe work environment. Results are presented and clearly show that the work environment is a relatively safe one, though still not good enough to keep from preventing injury. So, the journey to a zero injury work environment - both in measured reality and in the minds of each employee - continues. The intent of this paper is to provide a benchmark for others with operational environments and stimulate additional sharing and discussion on having and keeping a safe work environment.

  8. Check Verbraucherpolitik und Verbraucherbeteiligung

    DEFF Research Database (Denmark)

    Hagen, Kornelia; Micklitz, Hans-W.; Oehler, Andreas

    2013-01-01

    The paper discusses the opportunities for an empirically grounded decision support system as an instrument for independent and scientifically based consumer policy consulting. To date, consumer policy is dominated by the information paradigm and the leitbild of the rational, sovereign...... and information-seeking consumer. Yet, both everyday practice and research in behavioural economics show that this view lacks empirical ground. In fact, there are different consumer types and different forms of rationalities at work. Effective consumer policy making should be based on the empirically revealed...... an empirically based “Check Consumer Policy and Consumer Participation” as a systematic decision and evaluation tool for policy makers. This check should be independent from the government and should be grounded on an empirical view of the consumer. Consumer policy tools should be tested with real consumers...

  9. QuickChecking static analysis properties

    DEFF Research Database (Denmark)

    Midtgaard, Jan; Møller, Anders

    2017-01-01

    A static analysis can check programs for potential errors. A natural question that arises is therefore: who checks the checker? Researchers have given this question varying attention, ranging from basic testing techniques, informal monotonicity arguments, thorough pen-and-paper soundness proofs....... Moreover, we offer a number of generic, type-safe combinators to check transfer functions and operators on lattices, to help ensure that these are, eg, monotone, strict, or invariant. We substantiate our claims by quickchecking a type analysis for the Lua programming language....

  10. QuickChecking Static Analysis Properties

    DEFF Research Database (Denmark)

    Midtgaard, Jan; Møller, Anders

    2015-01-01

    A static analysis can check programs for potential errors. A natural question that arises is therefore: who checks the checker? Researchers have given this question varying attention, ranging from basic testing techniques, informal monotonicity arguments, thorough pen-and-paper soundness proofs...... of a lattice. Moreover, we offer a number of generic, type-safe combinators to check transfer functions and operators on lattices, to help ensure that these are, e.g., monotone, strict, or invariant. We substantiate our claims by quickchecking a type analysis for the Lua programming language...

  11. WCET Analysis of ARM Processors using Real-Time Model Checking

    DEFF Research Database (Denmark)

    Toft, Martin; Olesen, Mads Christian; Dalsgaard, Andreas

    2009-01-01

    This paper presents a flexible method that utilises real-time model checking to determine safe and sharp WCETs for processes running on hardware platforms featuring pipelining and caching.......This paper presents a flexible method that utilises real-time model checking to determine safe and sharp WCETs for processes running on hardware platforms featuring pipelining and caching....

  12. STABILITAS CHECK DAM DI ARBORETUM DESA SUMBER BRANTAS

    Directory of Open Access Journals (Sweden)

    Endang Purwati

    2012-09-01

    Full Text Available Abstract: The stability of check-dam in arboretum of Sumber Brantas village. Sumber Brantas water sources area is arboretum territory which has to be maintained as conservation either for technical or vegetation (plants cover by sustainable development. Arboretum territory is made as asylum in irrigation system district of Brantas River. This research discusses technical conservation activity to build the check dam in conserving the area. Check dam is built dimensionally by using HEC-RAS Program to get safe and stable dimension for rolling, shifting and piping of Sf > 1.5, and based on hydrologic analysis to get maximum flood discharge of 48.01 m3second-1. Hydraulic analysis is used to get water level profile and pressure for the dam body. Stability of the structure will be controlled by construction load (weight of check dam and its fully sediment storage condition. The result of this research shows that the safe and stable dimension for check dam are as follows: 28 meter of width; 3 meter of main height; 1.5 meter of sub-height; 10 meter of stilling basin length (Main Dam–Sub Dam.

  13. A Survey of Restraint Methods for the Safe Transport of Children in Ground Ambulances.

    Science.gov (United States)

    Woods, Rashida H; Shah, Manish; Doughty, Cara; Gilchrest, Anthony

    2018-03-01

    The National Highway Traffic Safety Administration (NHTSA) released draft recommendations in 2010 on the safe transport of children in ground ambulances. The purpose of this study was to assess awareness of these guidelines among emergency medical service (EMS) agencies and to identify implementation barriers. We conducted a cross-sectional, anonymous online survey of 911-responding, ground transport EMS agencies in Texas. Demographics, modes of transport based on case scenarios, and barriers to implementation were assessed. Of 62 eligible EMS agencies that took the survey, 35.7% were aware of the NHTSA guidelines, 62.5% agreed they would improve safety, and 41.1% planned to implement them. Seventy-five percent of EMS agencies used the ideal or acceptable alternative to transport children requiring continuous monitoring, and 69.5% chose ideal or acceptable alternatives for children requiring spinal immobilization. The ideal or acceptable alternative was not chosen for children who were not injured or ill (93.2%), ill or injured but not requiring continuous monitoring (53.3%), and situations when multiple patients required transport (57.6%). The main requirements for implementation were provider education, ambulance interior modifications, new guidelines in the EMS agency, and purchase of new equipment. Few EMS agencies are aware of the NHTSA guidelines on safe transport of children in ground ambulances. Although most agencies appropriately transport children who require monitoring, interventions, or spinal immobilization, they use inappropriate means to transport children in situations with multiple patients, lack of injury or illness, or lack of need for monitoring.

  14. Pharmacist and Technician Perceptions of Tech-Check-Tech in Community Pharmacy Practice Settings.

    Science.gov (United States)

    Frost, Timothy P; Adams, Alex J

    2018-04-01

    Tech-check-tech (TCT) is a practice model in which pharmacy technicians with advanced training can perform final verification of prescriptions that have been previously reviewed for appropriateness by a pharmacist. Few states have adopted TCT in part because of the common view that this model is controversial among members of the profession. This article aims to summarize the existing research on pharmacist and technician perceptions of community pharmacy-based TCT. A literature review was conducted using MEDLINE (January 1990 to August 2016) and Google Scholar (January 1990 to August 2016) using the terms "tech* and check," "tech-check-tech," "checking technician," and "accuracy checking tech*." Of the 7 studies identified we found general agreement among both pharmacists and technicians that TCT in community pharmacy settings can be safely performed. This agreement persisted in studies of theoretical TCT models and in studies assessing participants in actual community-based TCT models. Pharmacists who had previously worked with a checking technician were generally more favorable toward TCT. Both pharmacists and technicians in community pharmacy settings generally perceived TCT to be safe, in both theoretical surveys and in surveys following actual TCT demonstration projects. These perceptions of safety align well with the actual outcomes achieved from community pharmacy TCT studies.

  15. Schedulability of Herschel revisited using statistical model checking

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Legay, Axel

    2015-01-01

    -approximation technique. We can safely conclude that the system is schedulable for varying values of BCET. For the cases where deadlines are violated, we use polyhedra to try to confirm the witnesses. Our alternative method to confirm non-schedulability uses statistical model-checking (SMC) to generate counter...... and blocking times of tasks. Consequently, the method may falsely declare deadline violations that will never occur during execution. This paper is a continuation of previous work of the authors in applying extended timed automata model checking (using the tool UPPAAL) to obtain more exact schedulability...... analysis, here in the presence of non-deterministic computation times of tasks given by intervals [BCET,WCET]. Computation intervals with preemptive schedulers make the schedulability analysis of the resulting task model undecidable. Our contribution is to propose a combination of model checking techniques...

  16. Symbolic Game Semantics for Model Checking Program Families

    DEFF Research Database (Denmark)

    Dimovski, Aleksandar

    2016-01-01

    represent program families with infinite integers as so-called (finite-state) featured symbolic automata. Specifically designed model checking algorithms are then employed to verify safety of all programs from a family at once and pinpoint those programs that are unsafe (respectively, safe). We present...... a prototype tool implementing this approach, and we illustrate it with several examples....

  17. Shake Warning: Helping People Stay Safe With Lots of Small Boxes in the Ground to Warn Them About Strong Shaking

    Science.gov (United States)

    Reusch, M.

    2017-12-01

    A group of people at schools are joining with the group of people in control of making pictures of the state of rocks on the ground and water in our land. They are working on a plan to help all people be safe in the case of very big ground shaking (when ground breaks in sight or under ground). They will put many small boxes all over the states in the direction of where the sun sets to look for the first shake that might be a sign of an even bigger shake to come. They tell a big computer (with much power) in several large cities in those states. These computers will decide if the first shake is a sign of a very large and close ground shake, a far-away ground shake, a small but close ground shake, or even just a sign of a shake that people wanted to make. If it is a sign of a close and really big shake, then the computers will tell the phones and computers of many people to help them take safe steps before the big shaking arrives where they are. This warning might be several seconds or maybe a couple of minutes. People will be able to hide, take cover, and hold on under tables and desks in case things fall from walls and places up high in their home and work. Doctors will be able to pause hard work and boxes that move people up and down in homes, businesses, and stores will be able to stop on the next floor and open their doors to let people out and not get stuck. It will help slow down trains to be safe and not fly off of the track as well as it will help to shut off water and air that warms homes and is used for when you make food hot. To make this plan become real, people who work for these groups are putting more small boxes in areas where there are not enough and that there are many people. They are also putting small boxes in places where there are no boxes but the big shake might come from that direction. There are problems to get past such as needing many more small boxes, more people to help with this plan, and getting all people who live in these areas to

  18. Radiocarbon ages of ground water as a basis for the determination of safe limits of aquifer exploitation

    International Nuclear Information System (INIS)

    Tamers, M.A.; Stipp, J.J.; Weiner, R.

    1975-01-01

    Deep ground waters of the Biscayne aquifer of south Florida were studied with radiocarbon dating techniques. Dissolved carbonates served as the material for the age determinations. Limestone dilution corrections of the measured carbon-14 activities were made by comparison of the relative concentrations of bicarbonate and total carbonates. The deep well waters of the southern portion of the deposit have corrected radiocarbon contents indicating thermonuclear weapon testing contamination; they are, therefore, less than 20 years old. The ages of the ground waters generally increase in the northern direction. This is interpreted as due to the greater depth of the deposit of that region. A model is formulated for ground water movement in an unconfined producing hydrological unit and applied to the radiocarbon results of the most intensively exploited zone of the Biscayne aquifer. It is shown that the water which is extracted by the municipal wells in this area is limited to the bottom third of the deposit. The avoidance of pollution from the surrounding septic tanks in the shallower depths of the area is explained in this way. The model leads to an objective estimation of the safe limit for the ground water extraction rate in the zone. By application of radiocarbon dating, it is possible to obtain useful information without disturbing the water supply

  19. Mask induction despite circuit obstruction: an unrecognized hazard of relying on automated machine check technology.

    Science.gov (United States)

    Yang, Kamie K; Lewis, Ian H

    2014-06-15

    Various equipment malfunctions of anesthesia gas delivery systems have been previously reported. Our profession increasingly uses technology as a means to prevent these errors. We report a case of a near-total anesthesia circuit obstruction that went undetected before the induction of anesthesia despite the use of automated machine check technology. This case highlights that automated machine check modules can fail to detect severe equipment failure and demonstrates how, even in this era of expanding technology, manual checks still remain essential components of safe care.

  20. Check, check, double check: checking the autopilot causes distrust : Experimental studies on the effects of compulsive perseveration

    NARCIS (Netherlands)

    Dek, E.C.P.

    2015-01-01

    Obsessive-compulsive disorder (OCD) is characterized by persistent doubt. The majority of patients with OCD engage in repeated checking to reduce these feelings of uncertainty. However, numerous studies demonstrated that repetitive behavior ironically increases uncertainty: perseverative checking

  1. 32 CFR Appendix A to Part 86 - Criminal History Background Check Procedures

    Science.gov (United States)

    2010-07-01

    ... responsibility in ensuring a safe and secure environment for children within DoD activities or private... installation level. An IRC will be completed on individuals with a DoD affiliation such as living or working on... checks through the SCHR to personnel offices working with law enforcement or investigative agencies. They...

  2. Grounding-Induced Sectional Forces and Residual Strength of Grounded Ship Hulls

    DEFF Research Database (Denmark)

    Paik, Jeom Kee; Pedersen, Preben Terndrup

    1996-01-01

    The aim of the present study is to determine the sectional forces induced by ship grounding and also to assess the residual strength of groundedship hulls. An analytical approach is used to estimate the grounding-induced sectional forces of ships. The extent and location of structural damage due...... to grounding is defined based on the ABS Safe Hull guide. The residual strength of damaged hulls is calculated by using a simple analytical formula. The method is applied to residual strength assessment of a damaged double hull tanker of 38,400 dwt due to grounding....

  3. Ultrasonic Detectors Safely Identify Dangerous, Costly Leaks

    Science.gov (United States)

    2013-01-01

    In 1990, NASA grounded its space shuttle fleet. The reason: leaks detected in the hydrogen fuel systems of the Space Shuttles Atlantis and Columbia. Unless the sources of the leaks could be identified and fixed, the shuttles would not be safe to fly. To help locate the existing leaks and check for others, Kennedy Space Center engineers used portable ultrasonic detectors to scan the fuel systems. As a gas or liquid escapes from a leak, the resulting turbulence creates ultrasonic noise, explains Gary Mohr, president of Elmsford, New York-based UE Systems Inc., a long-time leader in ultrasonic detector technologies. "In lay terms, the leak is like a dog whistle, and the detector is like the dog ear." Because the ultrasound emissions from a leak are highly localized, they can be used not only to identify the presence of a leak but also to help pinpoint a leak s location. The NASA engineers employed UE s detectors to examine the shuttle fuel tanks and solid rocket boosters, but encountered difficulty with the devices limited range-certain areas of the shuttle proved difficult or unsafe to scan up close. To remedy the problem, the engineers created a long-range attachment for the detectors, similar to "a zoom lens on a camera," Mohr says. "If you are on the ground, and the leak is 50 feet away, the detector would now give you the same impression as if you were only 25 feet away." The enhancement also had the effect of reducing background noise, allowing for a clearer, more precise detection of a leak s location.

  4. Drinking Water Management and Governance in Canada: An Innovative Plan-Do-Check-Act (PDCA) Framework for a Safe Drinking Water Supply

    Science.gov (United States)

    Bereskie, Ty; Rodriguez, Manuel J.; Sadiq, Rehan

    2017-08-01

    Drinking water management in Canada is complex, with a decentralized, three-tiered governance structure responsible for safe drinking water throughout the country. The current approach has been described as fragmented, leading to governance gaps, duplication of efforts, and an absence of accountability and enforcement. Although there have been no major waterborne disease outbreaks in Canada since 2001, a lack of performance improvement, especially in small drinking water systems, is evident. The World Health Organization water safety plan approach for drinking water management represents an alternative preventative management framework to the current conventional, reactive drinking water management strategies. This approach has seen successful implementation throughout the world and has the potential to address many of the issues with drinking water management in Canada. This paper presents a review and strengths-weaknesses-opportunities-threats analysis of drinking water management and governance in Canada at the federal, provincial/territorial, and municipal levels. Based on this analysis, a modified water safety plan (defined as the plan-do-check-act (PDCA)-WSP framework) is proposed, established from water safety plan recommendations and the principles of PDCA for continuous performance improvement. This proposed framework is designed to strengthen current drinking water management in Canada and is designed to fit within and incorporate the existing governance structure.

  5. Drinking Water Management and Governance in Canada: An Innovative Plan-Do-Check-Act (PDCA) Framework for a Safe Drinking Water Supply.

    Science.gov (United States)

    Bereskie, Ty; Rodriguez, Manuel J; Sadiq, Rehan

    2017-08-01

    Drinking water management in Canada is complex, with a decentralized, three-tiered governance structure responsible for safe drinking water throughout the country. The current approach has been described as fragmented, leading to governance gaps, duplication of efforts, and an absence of accountability and enforcement. Although there have been no major waterborne disease outbreaks in Canada since 2001, a lack of performance improvement, especially in small drinking water systems, is evident. The World Health Organization water safety plan approach for drinking water management represents an alternative preventative management framework to the current conventional, reactive drinking water management strategies. This approach has seen successful implementation throughout the world and has the potential to address many of the issues with drinking water management in Canada. This paper presents a review and strengths-weaknesses-opportunities-threats analysis of drinking water management and governance in Canada at the federal, provincial/territorial, and municipal levels. Based on this analysis, a modified water safety plan (defined as the plan-do-check-act (PDCA)-WSP framework) is proposed, established from water safety plan recommendations and the principles of PDCA for continuous performance improvement. This proposed framework is designed to strengthen current drinking water management in Canada and is designed to fit within and incorporate the existing governance structure.

  6. Remote versus face-to-face check-ups for asthma.

    Science.gov (United States)

    Kew, Kayleigh M; Cates, Christopher J

    2016-04-18

    Evaluation (GRADE) approach. Six studies including a total of 2100 participants met the inclusion criteria: we pooled four studies including 792 people in the main efficacy analyses, and presented the results of a cluster implementation study (n = 1213) and an oral steroid tapering study (n = 95) separately. Baseline characteristics relating to asthma severity were variable, but studies generally recruited people with asthma taking regular medications and excluded those with COPD or severe asthma. One study compared the two types of check-up for oral steroid tapering in severe refractory asthma and we assessed it as a separate question. The studies could not be blinded and dropout was high in four of the six studies, which may have biased the results.We could not say whether more people who had a remote check-up needed oral corticosteroids for an asthma exacerbation than those who were seen face-to-face because the confidence intervals (CIs) were very wide (OR 1.74, 95% CI 0.41 to 7.44; 278 participants; one study; low quality evidence). In the face-to-face check-up groups, 21 participants out of 1000 had exacerbations that required oral steroids over three months, compared to 36 (95% CI nine to 139) out of 1000 for the remote check-up group. Exacerbations that needed treatment in the Emergency Department (ED), hospital admission or an unscheduled healthcare visit all happened too infrequently to detect whether remote check-ups are a safe alternative to face-to-face consultations. Serious adverse events were not reported separately from the exacerbation outcomes.There was no difference in asthma control measured by the Asthma Control Questionnaire (ACQ) or in quality of life measured on the Asthma Quality of Life Questionnaire (AQLQ) between remote and face-to-face check-ups. We could rule out significant harm of remote check-ups for these outcomes but we were less confident because these outcomes are more prone to bias from lack of blinding.The larger implementation study

  7. The Effects of Check-In, Check-Up, Check-Out for Students with Moderate Intellectual Disability during On- and Off-Site Vocational Training

    Science.gov (United States)

    Boden, Lauren J.; Jolivette, Kristine; Alberto, Paul A.

    2018-01-01

    Check-in/check-out is a secondary-tier intervention within the positive behavior interventions and supports framework. Check-in/check-out pairs the use of an adult mentor with a daily progress report to help students meet individualized behavioral goals. This study adds to the research base by examining the effects of check-in, check-up, check-out…

  8. Regular health checks

    DEFF Research Database (Denmark)

    Grønhøj Larsen, Christian; Jørgensen, Karsten Juhl; Gøtzsche, Peter C

    2012-01-01

    To investigate whether Danish providers of general health checks present a balanced account of possible benefits and harms on their websites and whether the health checks are evidence-based.......To investigate whether Danish providers of general health checks present a balanced account of possible benefits and harms on their websites and whether the health checks are evidence-based....

  9. Evaluation of the performance of the IQ-check kits and the USDA microbiology laboratory guidebook methods for detection of Shiga Toxin-Producing E. coli (STEC) and STEC and Salmonella simultaneously in ground beef

    Science.gov (United States)

    Aims: To evaluate the performance of the IQ-Check kits and the USDA Microbiology Laboratory Guidebook (MLG) methods for detection of the top 7 Shiga toxin-producing E. coli (STEC) (O157:H7, O26, O45, O103, O111, O121, and O145) in ground beef and both STEC and Salmonella in co-inoculated samples. M...

  10. Checking Java Programs

    CERN Document Server

    Darwin, Ian

    2007-01-01

    This Short Cut tells you about tools that will improve the quality of your Java code, using checking above and beyond what the standard tools do, including: Using javac options, JUnit and assertions Making your IDE work harder Checking your source code with PMD Checking your compiled code (.class files) with FindBugs Checking your program's run-time behavior with Java PathFinder

  11. Managing Cassini Safe Mode Attitude at Saturn

    Science.gov (United States)

    Burk, Thomas A.

    2010-01-01

    The Cassini spacecraft was launched on October 15, 1997 and arrived at Saturn on June 30, 2004. It has performed detailed observations and remote sensing of Saturn, its rings, and its satellites since that time. In the event safe mode interrupts normal orbital operations, Cassini has flight software fault protection algorithms to detect, isolate, and recover to a thermally safe and commandable attitude and then wait for further instructions from the ground. But the Saturn environment is complex, and safety hazards change depending on where Cassini is in its orbital trajectory around Saturn. Selecting an appropriate safe mode attitude that insures safe operation in the Saturn environment, including keeping the star tracker field of view clear of bright bodies, while maintaining a quiescent, commandable attitude, is a significant challenge. This paper discusses the Cassini safe table management strategy and the key criteria that must be considered, especially during low altitude flybys of Titan, in deciding what spacecraft attitude should be used in the event of safe mode.

  12. Using Stochastic Model Checking to Provision Complex Business Services

    DEFF Research Database (Denmark)

    Herbert, Luke Thomas; Sharp, Robin

    2012-01-01

    bounds on resources consumed during execution of business processes. Accurate resource provisioning is often central to ensuring the safe execution of a process. We first introduce a formalised core subset of the Business Process Modelling and Notation (BPMN), which we extend with probabilistic and non......-deterministic branching and reward annotations. We then develop an algorithm for the efficient translation of these models into the guarded command language used by the model checker PRISM, in turn enabling model checking of BPMN processes and allowing for the calculation of a wide range of quantitative properties...

  13. 14 CFR 121.411 - Qualifications: Check airmen (airplane) and check airmen (simulator).

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Qualifications: Check airmen (airplane) and... § 121.411 Qualifications: Check airmen (airplane) and check airmen (simulator). (a) For the purposes of this section and § 121.413: (1) A check airman (airplane) is a person who is qualified, and permitted...

  14. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  15. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  16. 14 CFR 91.1089 - Qualifications: Check pilots (aircraft) and check pilots (simulator).

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Qualifications: Check pilots (aircraft) and check pilots (simulator). 91.1089 Section 91.1089 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... RULES Fractional Ownership Operations Program Management § 91.1089 Qualifications: Check pilots...

  17. WE-E-BRB-10: DosCheck - an Electronic Chart Checking Tool for Dosimetrists.

    Science.gov (United States)

    Yang, D; Wu, Y; Yaddanapudi, S; Moore, K; Pierbuxg, B; Brame, S; Mutic, S

    2012-06-01

    In addition to treatment planning, dosimetrists have to prepare documentation and manually enter data in treatment management system (TMS) which did not transfer or setup automatically. The required documents and data are dependent on the disease site, treatment machine and clinical workflow. Errors and inconsistencies can cause redundant work, treatment delays and potentially treatment errors. To address these issues, an electronic checking software tool, DosCheck was clinically implemented to check the existence of necessary documentations and the integrity of manually-entered data. The purpose of this software is to reduce the frequency of human errors and to improve efficiency. DosCheck reads data and documents from 1) TMS, 2) Pinnacle TPS, and 3) DICOM plan files stored in a DICOM-RT PACS. It processes documents in Word and PDF format, treatment plan data in Pinnacle native format and DICOM format, and Mosaiq data in database records. The software cross-checks data accuracy and consistency by following rules that are pre-defined according to the clinical requirements and treatment sties. It interacts with dosimetrists and presents instantaneous results via graphical user interface. DosCheck has been implemented in C#. It performs a full check for a patient with 20 seconds. It has been clinically commissioned and is used daily by all dosimetrists at our institution. Retrospective analysis shows that DosCheck identifies 30% to 40% of previously reported dosimetrist human errors. Additional ∼30% errors are checked by other tools that could be integrated DosCheck in the near future. As an electronic data checking tool, DosCheck can obtain and process data and documents from multiple clinical computer systems in the radiation oncology department, and perform checks according to clinical rules. It is able to improve the accuracy and efficiency of clinical data and document process, and therefore to reduce any potential inconsistencies and errors. © 2012 American

  18. Better super safe than slightly sorry? : Reciprocal relationships between checking behavior and cognitive symptoms in obsessive-compulsive disorder

    NARCIS (Netherlands)

    Toffolo, M.B.J.

    2015-01-01

    Obsessive-compulsive disorder(OCD) is characterized by intrusive frightening thoughts, images or impulses (obsessions; e.g., “did I stab my partner while doing the dishes?”) to which patients respond with repetitive behavior (compulsions; e.g., checking the knives and scissors in the house or

  19. Formal verification of reactor process control software using assertion checking environment

    International Nuclear Information System (INIS)

    Sharma, Babita; Balaji, Sowmya; John, Ajith K.; Bhattacharjee, A.K.; Dhodapkar, S.D.

    2005-01-01

    Assertion Checking Environment (ACE) was developed in-house for carrying out formal (rigorous/ mathematical) functional verification of embedded software written in MISRA C. MISRA C is an industrially sponsored safe sub-set of C programming language and is well accepted in the automotive and aerospace industries. ACE uses static assertion checking technique for verification of MISRA C programs. First the functional specifications of the program are derived from the specifications in the form of pre- and post-conditions for each C function. These pre- and post-conditions are then introduced as assertions (formal comments) in the program code. The annotated C code is then formally verified using ACE. In this paper we present our experience of using ACE for the formal verification of process control software of a nuclear reactor. The Software Requirements Document (SRD) contained textual specifications of the process control software. The SRD was used by the designers to draw logic diagrams which were given as input to a code generator. The verification of the generated C code was done at 2 levels viz. (i) verification against specifications derived from logic diagrams, and (ii) verification against specifications derived from SRD. In this work we checked approximately 600 functional specifications of the software having roughly 15000 lines of code. (author)

  20. Astronaut Neil A. Armstrong Undergoes Communications Systems Final Check

    Science.gov (United States)

    1969-01-01

    Dunned in his space suit, mission commander Neil A. Armstrong does a final check of his communications system before before the boarding of the Apollo 11 mission. Launched via a Saturn V launch vehicle, the first manned lunar mission launched from the Kennedy Space Center, Florida on July 16, 1969 and safely returned to Earth on July 24, 1969. The Saturn V vehicle was developed by the Marshall Space Flight Center (MSFC) under the direction of Dr. Wernher von Braun. The 3-man crew aboard the flight consisted of astronauts Armstrong; Michael Collins, Command Module (CM) pilot; and Edwin E. Aldrin, Jr., Lunar Module (LM) Pilot. Armstrong was the first human to ever stand on the lunar surface, followed by Edwin (Buzz) Aldrin. Meanwhile, astronaut Collins piloted the CM in a parking orbit around the Moon. During a 2½ hour surface exploration, the crew collected 47 pounds of lunar surface material which was returned to Earth for analysis. With the success of Apollo 11, the national objective to land men on the Moon and return them safely to Earth had been accomplished.

  1. Assertion checking environment (ACE) for formal verification of C programs

    International Nuclear Information System (INIS)

    Sharma, Babita; Dhodapkar, S.D.; Ramesh, S.

    2003-01-01

    In this paper we describe an Assertion Checking Environment (ACE) for compositional verification of programs, which are written in an industrially sponsored safe subset of C programming language called MISRA C [Guidelines for the Use of the C Language in Vehicle Based Software, 1998]. The theory is based on Hoare logic [Commun. ACM 12 (1969) 576] and the C programs are verified using static assertion checking technique. First the functional specifications of the program, captured in the form of pre- and post-conditions for each C function, are derived from the specifications. These pre- and post-conditions are then introduced as assertions (also called annotations or formal comments) in the program code. The assertions are then proved formally using ACE and theorem proving tool called Stanford Temporal Prover [The Stanford Temporal Prover User's Manual, 1998]. ACE has been developed by us and consists mainly of a translator c2spl, a GUI and some utility programs. The technique and tools developed are targeted towards verification of real-time embedded software

  2. Must we review printed lab reports without checking them? A prospective analysis of emergency department practice.

    LENUS (Irish Health Repository)

    McCabe, A

    2012-04-01

    This study investigated if results of haematology and biochemistry laboratory tests, carried out at the point of care in our Emergency Department, are checked by the clinician who ordered the test, mitigating the requirement to check printed reports later. Five hundred and nineteen (519) laboratory reports were examined for significant abnormal results and documentation in clinical notes. Thirty percent (30%, n = 158) of these met the inclusion criteria for \\'significantly abnormal\\' laboratory results. Of the 158 significantly abnormal results, 34.8% (n = 55) were not documented in the ED clinical case notes. No patient was discharged inappropriately. Our study suggests it is safe to stop routinely rechecking printed biochemistry and haematology laboratory reports in our department.

  3. Rigour and grounded theory.

    Science.gov (United States)

    Cooney, Adeline

    2011-01-01

    This paper explores ways to enhance and demonstrate rigour in a grounded theory study. Grounded theory is sometimes criticised for a lack of rigour. Beck (1993) identified credibility, auditability and fittingness as the main standards of rigour for qualitative research methods. These criteria were evaluated for applicability to a Straussian grounded theory study and expanded or refocused where necessary. The author uses a Straussian grounded theory study (Cooney, In press) to examine how the revised criteria can be applied when conducting a grounded theory study. Strauss and Corbin (1998b) criteria for judging the adequacy of a grounded theory were examined in the context of the wider literature examining rigour in qualitative research studies in general and grounded theory studies in particular. A literature search for 'rigour' and 'grounded theory' was carried out to support this analysis. Criteria are suggested for enhancing and demonstrating the rigour of a Straussian grounded theory study. These include: cross-checking emerging concepts against participants' meanings, asking experts if the theory 'fit' their experiences, and recording detailed memos outlining all analytical and sampling decisions. IMPLICATIONS FOR RESEARCH PRACTICE: The criteria identified have been expressed as questions to enable novice researchers to audit the extent to which they are demonstrating rigour when writing up their studies. However, it should not be forgotten that rigour is built into the grounded theory method through the inductive-deductive cycle of theory generation. Care in applying the grounded theory methodology correctly is the single most important factor in ensuring rigour.

  4. Repeated checking causes memory distrust

    NARCIS (Netherlands)

    van den Hout, M.; Kindt, M.

    2003-01-01

    This paper attempts to explain why in obsessive-compulsive disorder (OCD) checkers distrust in memory persists despite extensive checking. It is argued that: (1) repeated checking increases familiarity with the issues checked; (2) increased familiarity promotes conceptual processing which inhibits

  5. 30 CFR 77.906 - Trailing cables supplying power to low-voltage mobile equipment; ground wires and ground check...

    Science.gov (United States)

    2010-07-01

    ... portable or mobile equipment from low-voltage three-phase resistance grounded power systems shall contain... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables supplying power to low-voltage... STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage...

  6. What is a good health check? An interview study of health check providers' views and practices.

    Science.gov (United States)

    Stol, Yrrah H; Asscher, Eva C A; Schermer, Maartje H N

    2017-10-02

    Health checks identify (risk factors for) disease in people without symptoms. They may be offered by the government through population screenings and by other providers to individual users as 'personal health checks'. Health check providers' perspective of 'good' health checks may further the debate on the ethical evaluation and possible regulation of these personal health checks. In 2015, we interviewed twenty Dutch health check providers on criteria for 'good' health checks, and the role these criteria play in their practices. Providers unanimously formulate a number of minimal criteria: Checks must focus on (risk factors for) treatable/preventable disease; Tests must be reliable and clinically valid; Participation must be informed and voluntary; Checks should provide more benefits than harms; Governmental screenings should be cost-effective. Aspirational criteria mentioned were: Follow-up care should be provided; Providers should be skilled and experienced professionals that put the benefit of (potential) users first; Providers should take time and attention. Some criteria were contested: People should be free to test on any (risk factor for) disease; Health checks should only be performed in people at high risk for disease that are likely to implement health advice; Follow up care of privately funded tests should not drain on collective resources. Providers do not always fulfil their own criteria. Their reasons reveal conflicts between criteria, conflicts between criteria and other ethical values, and point to components in the (Dutch) organisation of health care that hinder an ethical provision of health checks. Moreover, providers consider informed consent a criterion that is hard to establish in practice. According to providers, personal health checks should meet the same criteria as population screenings, with the exception of cost-effectiveness. Providers do not always fulfil their own criteria. Results indicate that in thinking about the ethics of health

  7. The journey from safe yield to sustainability.

    Science.gov (United States)

    Alley, William M; Leake, Stanley A

    2004-01-01

    Safe-yield concepts historically focused attention on the economic and legal aspects of ground water development. Sustainability concerns have brought environmental aspects more to the forefront and have resulted in a more integrated outlook. Water resources sustainability is not a purely scientific concept, but rather a perspective that can frame scientific analysis. The evolving concept of sustainability presents a challenge to hydrologists to translate complex, and sometimes vague, socioeconomic and political questions into technical questions that can be quantified systematically. Hydrologists can contribute to sustainable water resources management by presenting the longer-term implications of ground water development as an integral part of their analyses.

  8. Parallel Algorithms for Model Checking

    NARCIS (Netherlands)

    van de Pol, Jaco; Mousavi, Mohammad Reza; Sgall, Jiri

    2017-01-01

    Model checking is an automated verification procedure, which checks that a model of a system satisfies certain properties. These properties are typically expressed in some temporal logic, like LTL and CTL. Algorithms for LTL model checking (linear time logic) are based on automata theory and graph

  9. Is the Routine Check Nephrostogram Following Percutaneous Antegrade Ureteric Stent Placement Necessary?

    International Nuclear Information System (INIS)

    Soh, Keng Chuan; Tay, Kiang Hiong; Tan, Bien Soo; MM Htoo, Austin; HG Lo, Richard; Lin, Shueh En

    2008-01-01

    Our aim was to review our experience with percutaneous antegrade ureteric stent (PAUS) placement and to determine if the routinely conducted check nephrostogram on the day following ureteric stent placement was necessary. Retrospective review of patients who had undergone PAUS placement between January 2004 and December 2005 was performed. There were 83 subjects (36 males, 47 females), with a mean age of 59.9 years (range, 22-94 years). Average follow-up duration was 7.1 months (range, 1-24 months). The most common indications for PAUS placement were ureteric obstruction due to metastatic disease (n = 56) and urinary calculi (n = 34). Technical success was 93.2% (96/103 attempts), with no major immediate procedure-related complications or mortalities. The Bard 7Fr Urosoft DJ Stent was used in more than 95% of the cases. Eighty-one of 89 (91.0%) check nephrostograms demonstrated a patent ureteric stent with resultant safety catheter removal. Three check nephrostograms revealed distal stent migration requiring repositioning by a goose-snare, while five others showed stent occlusion necessitating permanent external drainage by nephrostomy drainage catheter reinsertion. Following PAUS placement, the serum creatinine level improved or stabilized in 82% of patients. The serum creatinine outcome difference between the groups with benign and malignant indications for PAUS placement was not statistically significant (p = 0.145) but resolution of hydronephrosis was significantly better (p = 0.008) in patients with benign indications. Percutaneous antegrade ureteric stent placement is a safe and effective means of relief for ureteric obstruction. The check nephrostogram following ureteric stent placement was unnecessary in the majority of patients

  10. A pacemaker magnet check alone is sufficient for the majority of patients postpacemaker implant.

    Science.gov (United States)

    Jones, Michael A; Wong, Kelvin C K; Qureshi, Norman; Rajappan, Kim; Bashir, Yaver; Betts, Timothy R

    2014-12-01

    Patients postpacemaker implant can undergo a full assessment by pacing system programmer (PSP) or a magnet check. The former takes longer, but provides more detailed information; a magnet-mode assessment is faster, but provides only capture data in an asynchronous pacing mode. A magnet-mode assessment alone may be sufficient in most cases, and current clinical practice varies considerably. A retrospective single-center assessment of all pacemaker implants receiving PSP and magnet checks between September 2009 and April 2010. Patient records were reviewed. The results of PSP and magnet checks and any subsequent device-related management were noted. A total of 168 patients underwent pacemaker implantation, magnet-mode assessment, and then PSP interrogation during this period. Magnet-mode assessment revealed a problem in only one patient-failure of atrial capture, leading to subsequent atrial lead repositioning. None of the remaining 167 patients have a serious problem at PSP interrogation; six had minor issues at PSP check, none of which required repeat surgical intervention. The magnet-mode test only provides information on lead capture in an asynchronous pacing mode, which is the most essential data postoperatively. Our study has suggested that a magnet-mode assessment without PSP interrogation may be sufficient in the immediate postimplant assessment of these patients. Routine postimplant PSP interrogation is time consuming, labor intensive, and adds only minimal additional benefit to the safe management of these patients above and beyond a magnet check, coupled with informed assessment of the associated electrocardiogram/rhythm strip, clinical examination, and chest x-ray. ©2014 Wiley Periodicals, Inc.

  11. Software functions for safe operation - learning from Sizewell-B

    International Nuclear Information System (INIS)

    Welbourne, D.

    1996-01-01

    Future nuclear plants will use computer-based systems extensively. Regulatory acceptance must be planned and not underestimated. Commercial software packages will simplify it, but costly analysis and demonstration may be needed. Multiplexed control needs preparation of extensive configuration data and careful checking. On-screen soft control will need consideration of the integrity of the control path. Display design should follow human factors analysis of the operators' needs, and display layout needs great care for clarity. Computer-based system with planned quality will then bring great benefits in safe operation. (author) 1 fig., 3 refs

  12. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  13. 27 CFR 70.101 - Bad checks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Bad checks. 70.101 Section....101 Bad checks. If any check or money order in payment of any amount receivable under Title 26 of the... appropriate TTB officer that such check was tendered in good faith and that such person had reasonable cause...

  14. Check In / Check Out. The Public Space as an Internet of Things

    NARCIS (Netherlands)

    van t Hof, C.C.G.; van Est, R.; Daemen, F.

    2011-01-01

    Mobile phones, public transport smart cards, security cameras and GPS systems in our car - we are surrounded by digital devices. They track us, guide us, help us, and control us. The book Check In / Check Out. The Public Space as an Internet of Things shows us how our digital and physical worlds are

  15. Check in / check out : the public space as an internet of things

    NARCIS (Netherlands)

    Hof, van 't C.; Est, van R.; Daemen, F.

    2011-01-01

    Mobile phones, public transport smart cards, security cameras and GPS systems in our car - we are surrounded by digital devices. They track us, guide us, help us, and control us. The book Check In / Check Out. The Public Space as an Internet of Things shows us how our digital and physical worlds are

  16. What is a good health check? An interview study of health check providers' views and practices

    NARCIS (Netherlands)

    Y. Stol (Yrrah); E.C.A. Asscher (Eva); M.H.N. Schermer (Maartje)

    2017-01-01

    markdownabstract__Background:__ Health checks identify (risk factors for) disease in people without symptoms. They may be offered by the government through population screenings and by other providers to individual users as 'personal health checks'. Health check providers' perspective of 'good'

  17. Molecular double-check strategy for the identification and characterization of European Lyssaviruses

    DEFF Research Database (Denmark)

    Fischer, Melina; Freuling, Conrad M.; Müller, Thomas

    2014-01-01

    The “gold standard” for post-mortem rabies diagnosis is the direct fluorescent antibody test (FAT). However, in the case of ante-mortem non-neural sample material or decomposed tissues, the FAT reaches its limit, and the use of molecular techniques can be advantageous. In this study, we developed......-systems for Rabies virus, European bat lyssavirus type 1 and 2 as well as Bokeloh bat lyssavirus. All assays were validated successfully with a comprehensive panel of lyssavirus positive samples, as well as negative material from various host species. This double-check strategy allows for both safe and sensitive...

  18. checkCIF/PLATON (full publication check)

    Indian Academy of Sciences (India)

    editor handling your paper, to upload your CIF via our web site. PLATON version of 05/02/2014; check.def file version of 05/02/2014. Datablock I - ellipsoid plot http://vm02b.iucr.org/cgi-bin/checkcif_hkl.pl(第 3/4 页)2014-2-12 09:09:12 ...

  19. Effective ambiguity checking in biosequence analysis

    Directory of Open Access Journals (Sweden)

    Giegerich Robert

    2005-06-01

    Full Text Available Abstract Background Ambiguity is a problem in biosequence analysis that arises in various analysis tasks solved via dynamic programming, and in particular, in the modeling of families of RNA secondary structures with stochastic context free grammars. Several types of analysis are invalidated by the presence of ambiguity. As this problem inherits undecidability (as we show here from the namely problem for context free languages, there is no complete algorithmic solution to the problem of ambiguity checking. Results We explain frequently observed sources of ambiguity, and show how to avoid them. We suggest four testing procedures that may help to detect ambiguity when present, including a just-in-time test that permits to work safely with a potentially ambiguous grammar. We introduce, for the special case of stochastic context free grammars and RNA structure modeling, an automated partial procedure for proving non-ambiguity. It is used to demonstrate non-ambiguity for several relevant grammars. Conclusion Our mechanical proof procedure and our testing methods provide a powerful arsenal of methods to ensure non-ambiguity.

  20. Peculiarities of toxic effects exerted by hexyl ether of 5-aminolevulinic acid and grounds for working our regulations of its safe production and application

    Directory of Open Access Journals (Sweden)

    Е.К. Vlasenko

    2017-09-01

    Full Text Available Our research object was hexyl ether of 5-aminolevulinic acid applied as plants growth regulator which was synthe-sized with an original technology by Bioorganic Chemistry Institute of Belarus National Academy of science. Our research goal was to determine peculiarities of toxic effects exerted by this new plants protector on experimental models in vivo/in vitro and to give grounds for hygienic standards of its contents in various media which were to provide its safe production and application. We conducted our research with the use of toxicological, physiological, hematological, biochemical, immu-nologic, cytogenetic, cytological, and statistical methods. We were the first to perform toxicological assessment of this new plants growth regulator under different regimes, doses and ways of introduction into laboratory animals' bodies and it helped us to detect its toxicometric parameters and peculiarities of its biological effects which became apparent through skin-resorptive and cumulative properties, irritating impacts on mucous tunics, moderate reproductive toxicity without sub-stantial signs of gonadotropic, mutagenic, and allergenic impacts on a body. We detected that toxic impacts exerted by the examined substance on a body was combined with membrane-tropic and cytotoxic effects. We determined criteria and limit-ing parameters of hazardous effects exerted by hexyl ether of 5-aminolevulinic acid in the course of a chronic experiment, and it gave us grounds for fixing allowable daily dose for a man and for working out a number of regulations on the sub-stance contents in environmental objects (working area air, water, and soil, in food raw materials, and in food products (grain, rape, rape and linen oil. The obtained results were used as a basis for fixing 9 hygienic standards and were used for the state registration of this plant growth regulator; it will provide its safe production and application in agriculture.

  1. Ground-based eye-safe networkable micro-pulse differential absorption and high spectral resolution lidar for water vapor and aerosol profiling in the lower troposphere

    Science.gov (United States)

    Repasky, K. S.; Spuler, S.; Hayman, M. M.; Bunn, C. E.

    2017-12-01

    Atmospheric water vapor is a greenhouse gas that is known to be a significant driver of weather and climate. Several National Research Council (NRC) reports have highlighted the need for improved water vapor measurements that can capture its spatial and temporal variability as a means to improve weather predictions. Researchers at Montana State University (MSU) and the National Center for Atmospheric Research (NCAR) have developed an eye-safe diode laser based micro-pulse differential absorption lidar (MP-DIAL) for water vapor profiling in the lower troposphere. The MP-DIAL is capable of long term unattended operation and is capable of monitoring water vapor in the lower troposphere in most weather conditions. Two MP-DIAL instruments are currently operational and have been deployed at the Front Range Air Pollution and Photochemistry Experiment (FRAPPE), the Plains elevated Convection at Night (PECAN) experiment, the Perdigão experiment, and the Land Atmosphere Feedback Experiment (LAFE). For each of these field experiments, the MP-DIAL was run unattended and provided near-continuous water vapor profiles, including periods of bright daytime clouds, from 300 m above the ground level to 4 km (or the cloud base) with 150 m vertical resolution and 5 minute temporal resolution. Three additional MP-DIAL instruments are currently under construction and will result in a network of five eye-safe MP-DIAL instruments for ground based weather and climate research experiments. Taking advantage of the broad spectral coverage and modularity or the diode based architecture, a high spectral resolution lidar (HSRL) measurement capabilities was added to the second MP-DIAL instrument. The HSRL capabilities will be operational during the deployment at the LAFE field experiment. The instrument architecture will be presented along with examples of data collected during recent field experiments.

  2. Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet

    Science.gov (United States)

    Baker, Paul; Repaci, Max; Sames, David

    1998-01-01

    Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.

  3. Model Checking Markov Chains: Techniques and Tools

    NARCIS (Netherlands)

    Zapreev, I.S.

    2008-01-01

    This dissertation deals with four important aspects of model checking Markov chains: the development of efficient model-checking tools, the improvement of model-checking algorithms, the efficiency of the state-space reduction techniques, and the development of simulation-based model-checking

  4. Pushover, Response Spectrum and Time History Analyses of Safe Rooms in a Poor Performance Masonry Building

    International Nuclear Information System (INIS)

    Mazloom, M.

    2008-01-01

    The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquake happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly

  5. A Decentralized Interactive Architecture for Aerial and Ground Mobile Robots Cooperation

    OpenAIRE

    Harik, El Houssein Chouaib; Guérin, François; Guinand, Frédéric; Brethé, Jean-François; Pelvillain, Hervé

    2014-01-01

    International audience; —This paper presents a novel decentralized interactive architecture for aerial and ground mobile robots cooperation. The aerial mobile robot is used to provide a global coverage during an area inspection, while the ground mobile robot is used to provide a local coverage of ground features. We include a human-in-the-loop to provide waypoints for the ground mobile robot to progress safely in the inspected area. The aerial mobile robot follows continuously the ground mobi...

  6. Model Checking Structured Infinite Markov Chains

    NARCIS (Netherlands)

    Remke, Anne Katharina Ingrid

    2008-01-01

    In the past probabilistic model checking hast mostly been restricted to finite state models. This thesis explores the possibilities of model checking with continuous stochastic logic (CSL) on infinite-state Markov chains. We present an in-depth treatment of model checking algorithms for two special

  7. Effect of Safe Water on Arsenicosis: A Follow-up Study.

    Science.gov (United States)

    Majumdar, Kunal K; Ghose, Aloke; Ghose, Nilima; Biswas, Anirban; Mazumder, D N Guha

    2014-04-01

    Arsenic pollution in groundwater, used for drinking purposes, has been envisaged as a problem of global concern. Treatment options for the management symptoms of chronic arsenicosis are limited. Mitigation option available for dealing with the health problem of ground water arsenic contamination rests mainly on supply of arsenic safe water in arsenic-endemic region of Indo-Bangladesh subcontinent. Limited information is available regarding the long-term effect of chronic arsenic toxicity after stoppage of consumption of arsenic-containing water. The current study was, therefore, done to assess, objectively, the effect of drinking arsenic safe water (water source in their houses were supplied with arsenic removal filters for getting arsenic-free water during the follow-up period. In participants belonging to Cohort-I, the skin score was found to improve significantly at the end of each year, and it was found to be reduced significantly from 2.17 ± 1.09 to 1.23 ± 1.17; P water on skin lesions. The systemic disease symptom score was also found to improve, but less significantly, at the end of 3 years in both the cohorts. Most important observation during the follow-up study was persistence of severe symptoms of chronic lung disease and severe skin lesion including Bowen's disease in spite of taking arsenic-safe water. Further, death could not be prevented to occur because of lung cancer and severe lung disease. It is, therefore, an urgent need to make arrangement for availability of safe water source among the arsenic-affected people in the district. Many of the people in the affected villages are not aware of contamination of their home tube wells with arsenic. Awareness generation and motivation of the people for testing their drinking water sources for arsenic and environmental interventions like rain water harvesting, ground water recharge, and restricting excessive use of ground water for domestic and agricultural purposes are also important to prevent further

  8. Low ground clearance vehicle detection and warning.

    Science.gov (United States)

    2015-06-01

    A Low Ground Clearance Vehicle Detection : System (LGCVDS) determines if a commercial : motor vehicle can successfully clear a highwayrail : grade crossing and notifies the driver when : his or her vehicle cannot safely traverse the : crossing. That ...

  9. Combining Static Model Checking with Dynamic Enforcement Using the Statecall Policy Language

    Science.gov (United States)

    Madhavapeddy, Anil

    Internet protocols encapsulate a significant amount of state, making implementing the host software complex. In this paper, we define the Statecall Policy Language (SPL) which provides a usable middle ground between ad-hoc coding and formal reasoning. It enables programmers to embed automata in their code which can be statically model-checked using SPIN and dynamically enforced. The performance overheads are minimal, and the automata also provide higher-level debugging capabilities. We also describe some practical uses of SPL by describing the automata used in an SSH server written entirely in OCaml/SPL.

  10. Software tool for physics chart checks.

    Science.gov (United States)

    Li, H Harold; Wu, Yu; Yang, Deshan; Mutic, Sasa

    2014-01-01

    Physics chart check has long been a central quality assurance (QC) measure in radiation oncology. The purpose of this work is to describe a software tool that aims to accomplish simplification, standardization, automation, and forced functions in the process. Nationally recognized guidelines, including American College of Radiology and American Society for Radiation Oncology guidelines and technical standards, and the American Association of Physicists in Medicine Task Group reports were identified, studied, and summarized. Meanwhile, the reported events related to physics chart check service were analyzed using an event reporting and learning system. A number of shortfalls in the chart check process were identified. To address these problems, a software tool was designed and developed under Microsoft. Net in C# to hardwire as many components as possible at each stage of the process. The software consists of the following 4 independent modules: (1) chart check management; (2) pretreatment and during treatment chart check assistant; (3) posttreatment chart check assistant; and (4) quarterly peer-review management. The users were a large group of physicists in the author's radiation oncology clinic. During over 1 year of use the tool has proven very helpful in chart checking management, communication, documentation, and maintaining consistency. The software tool presented in this work aims to assist physicists at each stage of the physics chart check process. The software tool is potentially useful for any radiation oncology clinics that are either in the process of pursuing or maintaining the American College of Radiology accreditation.

  11. 25 CFR 115.704 - May we accept for deposit into a trust account retirement checks/payments or pension fund checks...

    Science.gov (United States)

    2010-04-01

    ... checks/payments or pension fund checks/payments even though those funds are not specified in § 115.702... May we accept for deposit into a trust account retirement checks/payments or pension fund checks.../payments or pension fund checks/payments or any funds from sources that are not identified in the table in...

  12. [Pre-verbality in focusing and the need for self check. An attempt at "focusing check"].

    Science.gov (United States)

    Masui, T; Ikemi, A; Murayama, S

    1983-06-01

    Though the Focusing process is not entirely non-verbal, in Focusing, careful attention is paid by the Focuser and the Listener to the pre-verbal experiential process. In other words, Focusing involves attending to the felt sense that is not easily expressed in words immediately. Hence, during the process of learning to Focus, the Focusing teacher attempts to communicate the experiences of Focusing to the student which are not easily done by words. Due to such difficulties, the Focusing student may (and quite frequently does) mistake the experiential process in Focusing with other processes. Often, the felt sense can be confused with other phenomena such as "autogenic discharge". Also the Focuser may not stay with the felt sense and drift into "free association" or frequently, certain processes in "meditation" can be confused with Focusing. Therefore, there is a need for a "check" by which the Focusing student can confirm the Focusing experience for himself. For the Focusing student, such a "check" serves not only to confirm the Focusing process, but also an aid to learning Focusing. We will report here a "Focusing Check" which we developed by translating Eugene Gendlin's "Focusing Check" and making several modifications in it so that it will be more understandable to the Japanese. Along with the "Focusing Check" we developed, the authors discuss the need for such a check.

  13. From Collective Adaptive Systems to Human Centric Computation and Back: Spatial Model Checking for Medical Imaging

    Directory of Open Access Journals (Sweden)

    Gina Belmonte

    2016-07-01

    Full Text Available Recent research on formal verification for Collective Adaptive Systems (CAS pushed advancements in spatial and spatio-temporal model checking, and as a side result provided novel image analysis methodologies, rooted in logical methods for topological spaces. Medical Imaging (MI is a field where such technologies show potential for ground-breaking innovation. In this position paper, we present a preliminary investigation centred on applications of spatial model checking to MI. The focus is shifted from pure logics to a mixture of logical, statistical and algorithmic approaches, driven by the logical nature intrinsic to the specification of the properties of interest in the field. As a result, novel operators are introduced, that could as well be brought back to the setting of CAS.

  14. [Infection prevention check-in and infection prevention check-out to prevent nosocomial infections].

    Science.gov (United States)

    Kramer, A; Schilling, M; Heidecke, C D

    2010-02-01

    A precondition for the success of the prevention of SSI is the complete realisation of the proven anti-infective measures in form of the multi-barrier strategy or the so-called bundles. In daily practice it is important to follow the fixed instructions, i. e., to ensure a high compliance. In much the same way as an airline pilot or co-pilot must examine whether all instruments are functioning before each take-off, a comparable procedure should be developed as a pre-operative control for the observance of all -defined measures by the responsible surgeon and for the post-operative supervision by the patient. For the control of the observance of the defined pre-operative prevention measures, a check list with 12 items was developed, named the "infection prevention check-in". The check list is authorised by the responsible surgeon be-fore each operation. For the surveillance of the general hygiene in the post-operative period the "infection prevention check-out" with 14 items was developed. Thereby the patient is able to evaluate the staff's compliance with the hygienic measures at the time of dismissal. With the introduction of the check-lists a simple means is given to involve both the team of the surgeons and the ward staff, together with the patient, into the infection prophylaxis even more effectively. In order to assess the success of those measures, the influence on the rate of SSI is to be determined prospectively. Georg Thieme Verlag Stuttgart, New York.

  15. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  16. 25 CFR 11.421 - Bad checks.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Bad checks. 11.421 Section 11.421 Indians BUREAU OF... Criminal Offenses § 11.421 Bad checks. (a) A person who issues or passes a check or similar sight order for..., and the issuer failed to make good within 10 days after receiving notice of that refusal. ...

  17. Diagnostic information in compliance checking

    NARCIS (Netherlands)

    Ramezani Taghiabadi, E.; Fahland, D.; Aalst, van der W.M.P.

    2012-01-01

    Compliance checking is gaining importance as today's organizations need to show that operational processes are executed in a controlled manner while satisfying predefined (legal) requirements. Deviations may be costly and expose the organization to severe risks. Compliance checking is of growing

  18. Non intrusive check valve diagnostics at Bruce A

    International Nuclear Information System (INIS)

    Marsch, S.P.

    1997-01-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  19. Non intrusive check valve diagnostics at Bruce A

    Energy Technology Data Exchange (ETDEWEB)

    Marsch, S.P. [Ontario Hydro, Bruce Nuclear Generating Station A, Tiverton, ON (Canada)

    1997-07-01

    Bruce A purchased non intrusive check valve diagnostic equipment in 1995 to ensure operability and availability of critical check valves in the Station. Diagnostics can be used to locate and monitor check valve degradation modes. Bruce A initiated a pilot program targeting check valves with flow through them and ones that completed open or close cycles. Approaches to determine how to confirm operability of passive check valves using non intrusive techniques were explored. A sample population of seventy-three check valves was selected to run the pilot program on prior to complete implementation. The pilot program produced some significant results and some inconclusive results. The program revealed a major finding that check valve performance modeling is required to ensure continuous operability of check valves. (author)

  20. Implementing Check in/Check out for Students with Intellectual Disability in Self-Contained Classrooms

    Science.gov (United States)

    Boden, Lauren J.; Ennis, Robin P.; Jolivette, Kristine

    2012-01-01

    Check in/check out (CICO) is a secondary-tier intervention implemented within the framework of schoolwide positive behavior interventions and supports (SWPBIS) that uses school-based contingencies to encourage positive behavior. CICO is a five-step cycle which uses daily progress report cards (DPR) to monitor progress toward schoolwide or…

  1. Safe sex

    Science.gov (United States)

    ... sex; Sexually transmitted - safe sex; GC - safe sex; Gonorrhea - safe sex; Herpes - safe sex; HIV - safe sex; ... contact. STIs include: Chlamydia Genital herpes Genital warts Gonorrhea Hepatitis HIV HPV Syphilis STIs are also called ...

  2. Compositional and Quantitative Model Checking

    DEFF Research Database (Denmark)

    Larsen, Kim Guldstrand

    2010-01-01

    This paper gives a survey of a composition model checking methodology and its succesfull instantiation to the model checking of networks of finite-state, timed, hybrid and probabilistic systems with respect; to suitable quantitative versions of the modal mu-calculus [Koz82]. The method is based...

  3. Goat production check list

    DEFF Research Database (Denmark)

    Henriksen, Jørgen; Nielsen, Mette Benedicte Olaf; Madsen, Jørgen

    2009-01-01

    This check list, financed by DanChurchAid, highlights all issues should be carefully investigated before investing in distribution of goats and in interventions to assist poor rural communities to improve their livelihood through goat production.......This check list, financed by DanChurchAid, highlights all issues should be carefully investigated before investing in distribution of goats and in interventions to assist poor rural communities to improve their livelihood through goat production....

  4. 12 CFR Appendix A to Part 229 - Routing Number Guide to Next-Day Availability Checks and Local Checks

    Science.gov (United States)

    2010-01-01

    ... Checks and Local Checks A Appendix A to Part 229 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM AVAILABILITY OF FUNDS AND COLLECTION OF CHECKS... Association. The routing number takes two forms: a fractional form and a nine-digit form. A paying bank...

  5. Model Checking Real-Time Systems

    DEFF Research Database (Denmark)

    Bouyer, Patricia; Fahrenberg, Uli; Larsen, Kim Guldstrand

    2018-01-01

    This chapter surveys timed automata as a formalism for model checking real-time systems. We begin with introducing the model, as an extension of finite-state automata with real-valued variables for measuring time. We then present the main model-checking results in this framework, and give a hint...

  6. Can i just check...? Effects of edit check questions on measurement error and survey estimates

    NARCIS (Netherlands)

    Lugtig, Peter; Jäckle, Annette

    2014-01-01

    Household income is difficult to measure, since it requires the collection of information about all potential income sources for each member of a household.Weassess the effects of two types of edit check questions on measurement error and survey estimates: within-wave edit checks use responses to

  7. Scram system with continuos check

    International Nuclear Information System (INIS)

    Rodriguez Sacco, Walter.

    1976-02-01

    The equipment described pretends to be a further step to the use of integrated circuits in nuclear instrumentation, considering that this type of control was traditionally carried out on the bases of electromechanical elements. A continuous self-check method has been applied in accordance with the high reliability requiered for this type of equipments. The developed equipment fulfils the condition that any deficiency in its component elements, causes an anormal self-detected operation. The equipment covers two systems: the Scram one, that includes the sequence generator-detector, the rods check and scram chain, and the Check system that uses pulses from the sequence detector. (author) [es

  8. Model-Checking Discrete Duration Calculus

    DEFF Research Database (Denmark)

    Hansen, Michael Reichhardt

    1994-01-01

    can do model-checking. The subset we consider is expressive enough to formalize the requirements to the gas burner system given by A.P. Ravn (1993); but only for a discrete time domain. Model-checking is done by reducing the correctness problem ℳ|=𝒟 to the inclusion problem of regular...

  9. 31 CFR 248.6 - Recovery of original check.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Recovery of original check. 248.6... § 248.6 Recovery of original check. (a) If the claimant recovers an original check after he has... or agency concerned regarding the negotiability of such original check. (b) In the event the...

  10. CMM Interim Check (U)

    Energy Technology Data Exchange (ETDEWEB)

    Montano, Joshua Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-03-23

    Coordinate Measuring Machines (CMM) are widely used in industry, throughout the Nuclear Weapons Complex and at Los Alamos National Laboratory (LANL) to verify part conformance to design definition. Calibration cycles for CMMs at LANL are predominantly one year in length. Unfortunately, several nonconformance reports have been generated to document the discovery of a certified machine found out of tolerance during a calibration closeout. In an effort to reduce risk to product quality two solutions were proposed – shorten the calibration cycle which could be costly, or perform an interim check to monitor the machine’s performance between cycles. The CMM interim check discussed makes use of Renishaw’s Machine Checking Gauge. This off-the-shelf product simulates a large sphere within a CMM’s measurement volume and allows for error estimation. Data was gathered, analyzed, and simulated from seven machines in seventeen different configurations to create statistical process control run charts for on-the-floor monitoring.

  11. Co-simulation Platform for Train-to-Ground communications

    DEFF Research Database (Denmark)

    Yan, Ying; Bouaziz, Maha; Kassab, Mohamed

    The project SAFE4RAIL (SAFE architecture for Robust distributed Application Integration in roLling stock) from the Shift2Rail Joint Undertaking will provide a cosimulation platform based on hardware/software co-simulation. The platform will be used for Train-to-Ground (T2G) test environments...... in the context of the validation of the new wireless Train Control Management System (TCMS) transmission over LTE technologies in order to evaluate performances with realistic services and under various railway traffic conditions....

  12. Environmental Reality Check.

    Science.gov (United States)

    Manicone, Santo

    2001-01-01

    Discusses the importance of educational facilities conducting "reality check" self-audits to uncover the real truth behind underlying environmental problems. An environmental compliance multimedia checklist is included. (GR)

  13. 7 CFR 1944.540 - Requesting TSA checks.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 13 2010-01-01 2009-01-01 true Requesting TSA checks. 1944.540 Section 1944.540... TSA checks. (a) The initial TSA check may cover the applicant's needs for the first calendar month. If... the next whole month. (b) The initial advance of TSA grant funds may not be requested simultaneously...

  14. 40 CFR 86.328-79 - Leak checks.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Leak checks. 86.328-79 Section 86.328... Gasoline-Fueled and Diesel-Fueled Heavy-Duty Engines; Gaseous Exhaust Test Procedures § 86.328-79 Leak checks. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could...

  15. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline.

  16. Methodology for Check Valve Selection to Maintain the Integrity of Pipeline against the Check Valve Slam for the KIJANG Research Reactor

    International Nuclear Information System (INIS)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon

    2016-01-01

    The check valve slam results in a water hammer and unexpected system pressure rise in the pipeline. Sometimes, the pressure rise by check valve slam in the pipeline exceeds the design pressure and then it causes the rupture of pipeline. Therefore, check valve slam significantly influences on the integrity of pipe. Especially, this it is most likely to occur by check valve installed in the discharge of pump when one pump trips among the two or more running in parallel pump system. This study focuses on the check valve selection to maintain the integrity of PCS pipeline against the check valve slam. If design head for KJRR PCS pipeline is higher than the sum of static head and 11 m, any type check valves can be installed at the discharge of pump. However, if design head for KJRR PCS pipeline is lower than the sum of static head and 11 m, installation of swing and ball check on the discharge of pump must be avoid to prevent the rupture of PCS pipeline

  17. Incremental Integrity Checking: Limitations and Possibilities

    DEFF Research Database (Denmark)

    Christiansen, Henning; Martinenghi, Davide

    2005-01-01

    Integrity checking is an essential means for the preservation of the intended semantics of a deductive database. Incrementality is the only feasible approach to checking and can be obtained with respect to given update patterns by exploiting query optimization techniques. By reducing the problem...... to query containment, we show that no procedure exists that always returns the best incremental test (aka simplification of integrity constraints), and this according to any reasonable criterion measuring the checking effort. In spite of this theoretical limitation, we develop an effective procedure...

  18. Effect of safe water on arsenicosis: A follow-up study

    Directory of Open Access Journals (Sweden)

    Kunal K Majumdar

    2014-01-01

    Full Text Available Background: Arsenic pollution in groundwater, used for drinking purposes, has been envisaged as a problem of global concern. Treatment options for the management symptoms of chronic arsenicosis are limited. Mitigation option available for dealing with the health problem of ground water arsenic contamination rests mainly on supply of arsenic safe water in arsenic-endemic region of Indo-Bangladesh subcontinent. Limited information is available regarding the long-term effect of chronic arsenic toxicity after stoppage of consumption of arsenic-containing water. Objective: The current study was, therefore, done to assess, objectively, the effect of drinking arsenic safe water (<50 μg/L on disease manifestation of arsenicosis. Results: Manifestations of various skin lesions and systemic diseases associated with chronic arsenic exposure were ascertained initially by carrying on baseline study on 208 participants in Nadia (Cohort-I, with skin lesion and Cohort-II, without skin lesion using a scoring system, as developed by us, and compared objectively at the end of each year for 3 year follow-up period. All the participants who had arsenic contaminated drinking water source in their houses were supplied with arsenic removal filters for getting arsenic-free water during the follow-up period. In participants belonging to Cohort-I, the skin score was found to improve significantly at the end of each year, and it was found to be reduced significantly from 2.17 ± 1.09 to 1.23 ± 1.17; P < 0.001 at the end of 3 year′s intervention study indicating beneficial effect of safe water on skin lesions. The systemic disease symptom score was also found to improve, but less significantly, at the end of 3 years in both the cohorts. Most important observation during the follow-up study was persistence of severe symptoms of chronic lung disease and severe skin lesion including Bowen′s disease in spite of taking arsenic-safe water. Further, death could not be

  19. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  20. SCaN Network Ground Station Receiver Performance for Future Service Support

    Science.gov (United States)

    Estabrook, Polly; Lee, Dennis; Cheng, Michael; Lau, Chi-Wung

    2012-01-01

    Objectives: Examine the impact of providing the newly standardized CCSDS Low Density Parity Check (LDPC) codes to the SCaN return data service on the SCaN SN and DSN ground stations receivers: SN Current Receiver: Integrated Receiver (IR). DSN Current Receiver: Downlink Telemetry and Tracking (DTT) Receiver. Early Commercial-Off-The-Shelf (COTS) prototype of the SN User Service Subsystem Component Replacement (USS CR) Narrow Band Receiver. Motivate discussion of general issues of ground station hardware design to enable simple and cheap modifications for support of future services.

  1. Plant experience with check valves in passive systems

    Energy Technology Data Exchange (ETDEWEB)

    Pahladsingh, R R [GKN Joint Nuclear Power Plant, Dodewaard (Netherlands)

    1996-12-01

    In the design of the advanced nuclear reactors there is a tendency to introduce more passive safety systems. The 25 year old design of the GKN nuclear reactor is different from the present BWR reactors because of some special features, such as the Natural Circulation - and the Passive Isolation Condenser system. When reviewing the design, one can conclude that the plant has 25 years of experience with check valves in passive systems and as passive components in systems. The result of this experience has been modeled in a plant-specific ``living PSA`` for the plant. A data-analysis has been performed on components which are related to the safety systems in the plant. As part of this study also the check valves have been taken in consideration. At GKN, the check valves have shown to be reliable components in the systems and no catastrophic failures have been experienced during the 25 years of operation. Especially the Isolation Condenser with its operation experience can contribute substantially to the insight of check valves in stand-by position at reactor pressure and operating by gravity under different pressure conditions. With the introduction of several passive systems in the SBWR-600 design, such as the Isolation Condensers, Gravity Driven Cooling, and Suppression Pool Cooling System, the issue of reliability of check valves in these systems is actual. Some critical aspects for study in connection with check valves are: What is the reliability of a check valve in a system at reactor pressure, to open on demand; what is the reliability of a check valve in a system at low pressure (gravity), to open on demand; what is the reliability of a check valve to open/close when the stand-by check wave is at zero differential pressure. The plant experience with check valves in a few essential safety systems is described and a brief introduction will be made about the application of check valves in the design of the new generation reactors is given. (author). 6 figs, 1 tab.

  2. Automatization and familiarity in repeated checking

    NARCIS (Netherlands)

    Dek, E.C.P.|info:eu-repo/dai/nl/313959552; van den Hout, M.A.|info:eu-repo/dai/nl/070445354; Giele, C.L.|info:eu-repo/dai/nl/318754460; Engelhard, I.M.|info:eu-repo/dai/nl/239681533

    2015-01-01

    Repetitive, compulsive-like checking of an object leads to reductions in memory confidence, vividness, and detail. Experimental research suggests that this is caused by increased familiarity with perceptual characteristics of the stimulus and automatization of the checking procedure (Dek, van den

  3. An Envelope Based Feedback Control System for Earthquake Early Warning: Reality Check Algorithm

    Science.gov (United States)

    Heaton, T. H.; Karakus, G.; Beck, J. L.

    2016-12-01

    Earthquake early warning systems are, in general, designed to be open loop control systems in such a way that the output, i.e., the warning messages, only depend on the input, i.e., recorded ground motions, up to the moment when the message is issued in real-time. We propose an algorithm, which is called Reality Check Algorithm (RCA), which would assess the accuracy of issued warning messages, and then feed the outcome of the assessment back into the system. Then, the system would modify its messages if necessary. That is, we are proposing to convert earthquake early warning systems into feedback control systems by integrating them with RCA. RCA works by continuously monitoring and comparing the observed ground motions' envelopes to the predicted envelopes of Virtual Seismologist (Cua 2005). Accuracy of magnitude and location (both spatial and temporal) estimations of the system are assessed separately by probabilistic classification models, which are trained by a Sparse Bayesian Learning technique called Automatic Relevance Determination prior.

  4. Improvement of seawater booster pump outlet check valve

    International Nuclear Information System (INIS)

    Li Xuning; Du Yansong; Huang Huimin

    2010-01-01

    Conventional island seawater booster pump set of QNPC 310 MWe unit are very important in the whole circulating cooling system, and the integrate function of seawater booster pump outlet check valve is the foundation of steady operation of the seawater booster pump set. The article mainly introduce that through the analyses to the reason to the problem that the seawater booster pump outlet check valve of QNPC 310 MWe unit appeared in past years by our team, and considering the influence of operation condition and circumstance, the team improve the seawater booster pump outlet check valve from swing check valve to shuttle check valve which operate more appropriately in the system. By the test of continuous practice, we make further modification to the inner structure of shuttle check valve contrapuntally, and therefore we solve the problem in seawater booster pump outlet check valve fundamentally which has troubled the security of system operation in past years, so we realize the aim of technical improvement and ensure that the system operate in safety and stability. (authors)

  5. Critically safe volume vacuum pickup for use in wet or dry cleanup of radioactive enclosures

    International Nuclear Information System (INIS)

    Zeren, J.D.

    1993-01-01

    A physical compact vacuum pickup device of critically safe volume and geometric shape is provided for use in radioactive enclosures, such as a small glove box, to facilitate manual cleanup of either wet or dry radioactive material. The device is constructed and arranged so as to remain safe when filled to capacity with plutonium-239 oxide. Two fine mesh filter bags are supported on the exterior of a rigid fine mesh stainless steel cup. This assembly is sealed within, and spaced from, the interior walls of a stainless steel canister. An air inlet communicates with the interior of the canister. A modified conventional vacuum head is physically connected to, and associated with, the interior of the mesh cup. The volume of the canister, as defined by the space between the mesh cup and the interior walls of the canister, forms a critically safe volume and geometric shape for dry radioactive particles that are gathered within the canister. A critically safe liquid volume is maintained by operation of a suction terminating float valve, and/or by operation of redundant vacuum check/liquid drain valves and placement of the air inlet. 5 figures

  6. Diagnostic information in temporal compliance checking

    NARCIS (Netherlands)

    Ramezani Taghiabadi, E.; Fahland, D.; Dongen, van B.F.; Aalst, van der W.M.P.

    2012-01-01

    Compliance checking is gaining importance as today’s organizations need to show that operational processes are executed in a controlled manner while satisfying prede¿ned (legal) requirements. Deviations may be costly and expose the organization to severe risks. Compliance checking is of growing

  7. 31 CFR 245.8 - Receipt or recovery of original check.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Receipt or recovery of original check... CHECKS § 245.8 Receipt or recovery of original check. (a) If the original check is received or recovered... of instructions with respect to the negotiability of such check. (b) If the original check is...

  8. Ion beam analysis of ground coffee and roasted coffee beans

    International Nuclear Information System (INIS)

    Debastiani, R.; Santos, C.E.I. dos; Yoneama, M.L.; Amaral, L.; Dias, J.F.

    2014-01-01

    The way that coffee is prepared (using roasted ground coffee or roasted coffee beans) may influence the quality of beverage. Therefore, the aim of this work is to use ion beam techniques to perform a full elemental analysis of packed roasted ground coffee and packed roasted coffee beans, as well as green coffee beans. The samples were analyzed by PIXE (particle-induced X-ray emission). Light elements were measured through RBS (Rutherford backscattering spectrometry) experiments. Micro-PIXE experiments were carried out in order to check the elemental distribution in the roasted and green coffee beans. In general, the elements found in ground coffee were Mg, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu, Zn, Rb and Sr. A comparison between ground coffee and grinded roasted beans shows significant differences for several elements. Elemental maps reveal that P and K are correlated and practically homogeneously distributed over the beans

  9. Ion beam analysis of ground coffee and roasted coffee beans

    Energy Technology Data Exchange (ETDEWEB)

    Debastiani, R., E-mail: rafa_debas@yahoo.com.br; Santos, C.E.I. dos; Yoneama, M.L.; Amaral, L.; Dias, J.F.

    2014-01-01

    The way that coffee is prepared (using roasted ground coffee or roasted coffee beans) may influence the quality of beverage. Therefore, the aim of this work is to use ion beam techniques to perform a full elemental analysis of packed roasted ground coffee and packed roasted coffee beans, as well as green coffee beans. The samples were analyzed by PIXE (particle-induced X-ray emission). Light elements were measured through RBS (Rutherford backscattering spectrometry) experiments. Micro-PIXE experiments were carried out in order to check the elemental distribution in the roasted and green coffee beans. In general, the elements found in ground coffee were Mg, P, S, Cl, K, Ca, Ti, Mn, Fe, Cu, Zn, Rb and Sr. A comparison between ground coffee and grinded roasted beans shows significant differences for several elements. Elemental maps reveal that P and K are correlated and practically homogeneously distributed over the beans.

  10. Forgetting what you have checked: a link between working memory impairment and checking behaviors in obsessive-compulsive disorder.

    Science.gov (United States)

    Jaafari, N; Frasca, M; Rigalleau, F; Rachid, F; Gil, R; Olié, J-P; Guehl, D; Burbaud, P; Aouizerate, B; Rotgé, J-Y; Vibert, N

    2013-02-01

    Compulsive checking behaviors are common in obsessive-compulsive disorder (OCD). Several authors have suggested that these checking rituals could be related to memory deficits. Our aim was to test whether patients with OCD show working memory impairment in relation to their checking behavior. We evaluated the verbal and visuospatial components of patients' and controls' working memory using the reading span and backward location span tests. Checking behaviors were measured by recording participants' eye movements during an image comparison task using a non-invasive, infra-red TOBII 1750 eyetracker. Participants were seated, head-free, in a natural position in front of the eyetracker screen where the images were displayed. Patients with OCD made more gaze moves to compare images than controls. Both patients' working memory spans were reduced, and the patients' deficit in the comparison task was negatively related to their working memory spans. This work demonstrates that checking behavior in OCD is linked to a general reduction of the patients' verbal and visuospatial working memory span. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  11. Model Checking Infinite-State Markov Chains

    NARCIS (Netherlands)

    Remke, Anne Katharina Ingrid; Haverkort, Boudewijn R.H.M.; Cloth, L.

    2004-01-01

    In this paper algorithms for model checking CSL (continuous stochastic logic) against infinite-state continuous-time Markov chains of so-called quasi birth-death type are developed. In doing so we extend the applicability of CSL model checking beyond the recently proposed case for finite-state

  12. 38 CFR 21.4505 - Check delivery.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Check delivery. 21.4505...) VOCATIONAL REHABILITATION AND EDUCATION Education Loans § 21.4505 Check delivery. (a) General. Education... surviving spouse is enrolled for delivery by the educational institution. (b) Delivery and certification. (1...

  13. check cif.pdf

    Indian Academy of Sciences (India)

    AMMIN

    Calculated. Reported. Volume ... PLAT094_ALERT_2_C Ratio of Maximum / Minimum Residual Density .... 3.24 Report ... checkCIF was carefully designed to identify outliers and unusual parameters, but every test has its limitations and alerts ...

  14. 46 CFR 10.214 - Security Check.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Security Check. 10.214 Section 10.214 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY MERCHANT MARINE OFFICERS AND SEAMEN MERCHANT MARINER CREDENTIAL General Requirements for All Merchant Mariner Credentials § 10.214 Security Check. Until April 15, 2009...

  15. 7 CFR 58.243 - Checking quality.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Checking quality. 58.243 Section 58.243 Agriculture... Procedures § 58.243 Checking quality. All milk, milk products and dry milk products shall be subject to inspection and analysis by the dairy plant for quality and condition throughout each processing operation...

  16. Mothers' use of and attitudes to BabyCheck.

    OpenAIRE

    Thomson, Hilary; Ross, Sue; Wilson, Philip; McConnachie, Alex; Watson, Richard

    2002-01-01

    A copy of BabyCheck was sent to 497 mothers shortly after the birth of their baby. Six months later they were sent a questionnaire asking about their use of and attitudes to, BabyCheck. Questionnaires were returned by 323 (65%) mothers; 215 (67%) of them reported reading BabyCheck, the majority found it easy to understand (74%) and agreed with the advice (67%). Eighty-four (26%) of the mothers who returned the questionnaires reported using BabyCheck when their baby was ill; of these, 71% agre...

  17. CMM Interim Check Design of Experiments (U)

    Energy Technology Data Exchange (ETDEWEB)

    Montano, Joshua Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-07-29

    Coordinate Measuring Machines (CMM) are widely used in industry, throughout the Nuclear Weapons Complex and at Los Alamos National Laboratory (LANL) to verify part conformance to design definition. Calibration cycles for CMMs at LANL are predominantly one year in length and include a weekly interim check to reduce risk. The CMM interim check makes use of Renishaw’s Machine Checking Gauge which is an off-the-shelf product simulates a large sphere within a CMM’s measurement volume and allows for error estimation. As verification on the interim check process a design of experiments investigation was proposed to test a couple of key factors (location and inspector). The results from the two-factor factorial experiment proved that location influenced results more than the inspector or interaction.

  18. Liability of Banking Institutions for the Payment of Forged or Altered Checks in Colombia

    Directory of Open Access Journals (Sweden)

    Jorge Alberto Padilla Sánchez

    2017-07-01

    Full Text Available We face a trend to turn liability of financial institutions to strict liability for breach of their contractual obligations, trend that has been extended by the Colombian judicial activity to situations that do not have legal grounds, under the pretext of protecting the financial consumer as a subject of special protection by the law. Perhaps one of the most emblematic cases of this trend is the responsibility of banking institutions for payment of counterfeit or adulterated checks, which does have a legal mandate that allows distinguish it from the general system of responsibility of such entities.

  19. 7 CFR 1421.11 - Spot checks.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Spot checks. 1421.11 Section 1421.11 Agriculture... ASSISTANCE LOANS AND LOAN DEFICIENCY PAYMENTS FOR 2008 THROUGH 2012 General § 1421.11 Spot checks. (a) CCC... CCC access to the farm and storage facility as necessary to conduct collateral inspections, or “spot...

  20. 32 CFR 635.6 - Name checks.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Name checks. 635.6 Section 635.6 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS LAW ENFORCEMENT REPORTING Records Administration § 635.6 Name checks. (a) Information contained in military police records may be...

  1. Ground Control System Description Document

    International Nuclear Information System (INIS)

    Eric Loros

    2001-01-01

    The Ground Control System contributes to the safe construction and operation of the subsurface facility, including accesses and waste emplacement drifts, by maintaining the configuration and stability of the openings during construction, development, emplacement, and caretaker modes for the duration of preclosure repository life. The Ground Control System consists of ground support structures installed within the subsurface excavated openings, any reinforcement made to the rock surrounding the opening, and inverts if designed as an integral part of the system. The Ground Control System maintains stability for the range of geologic conditions expected at the repository and for all expected loading conditions, including in situ rock, construction, operation, thermal, and seismic loads. The system maintains the size and geometry of operating envelopes for all openings, including alcoves, accesses, and emplacement drifts. The system provides for the installation and operation of sensors and equipment for any required inspection and monitoring. In addition, the Ground Control System provides protection against rockfall for all subsurface personnel, equipment, and the engineered barrier system, including the waste package during the preclosure period. The Ground Control System uses materials that are sufficiently maintainable and that retain the necessary engineering properties for the anticipated conditions of the preclosure service life. These materials are also compatible with postclosure waste isolation performance requirements of the repository. The Ground Control System interfaces with the Subsurface Facility System for operating envelopes, drift orientation, and excavated opening dimensions, Emplacement Drift System for material compatibility, Monitored Geologic Repository Operations Monitoring and Control System for ground control instrument readings, Waste Emplacement/Retrieval System to support waste emplacement operations, and the Subsurface Excavation System

  2. 45 CFR 201.70 - Treatment of replacement checks.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Treatment of replacement checks. 201.70 Section... STATES FOR PUBLIC ASSISTANCE PROGRAMS Review and Audits § 201.70 Treatment of replacement checks. (a... (FFP) for replacement checks under titles I, VI-A, X, XIV, XVI (AABD) except under the circumstances...

  3. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focussed on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  4. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1990-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focused on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two noval nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  5. Check valve diagnostics utilizing acoustic and magnetic technologies

    International Nuclear Information System (INIS)

    Agostinelli, A.

    1991-01-01

    The potential hazards associated with check valve failures make it necessary to detect check valve problems before they cause significant damage. In the nuclear industry, check valve failures are known to have resulted in damaging water hammer conditions, overpressurization of low pressure systems, steam binding of auxiliary feedwater pumps, and other serious component damage in power plant environments. Similar problems exist in fossil power and various process industries, but the resources dedicated to valve maintenance issues are greatly reduced. However, the trend toward plant life extension, predictive maintenance, and maximum operating efficiency will raise the general awareness of check valve maintenance in commercial (non-nuclear) applications. Although this paper includes specific references to the nuclear industry, the check valve problem conditions and diagnostic techniques apply across all power and process plant environments. The ability to accurately diagnose check valve conditions using non-intrusive, predictive maintenance testing methods allows for a more cost-efficient, productive maintenance program. One particular diagnostic system, called Quickcheck trademark, assists utilities in addressing these concerns. This article presents actual field test data and analysis that demonstrate the power of check valve diagnostics. Prior to presenting the field data, a brief overview of the system is overviewed

  6. Design of power cable grounding wire anti-theft monitoring system

    Science.gov (United States)

    An, Xisheng; Lu, Peng; Wei, Niansheng; Hong, Gang

    2018-01-01

    In order to prevent the serious consequences of the power grid failure caused by the power cable grounding wire theft, this paper presents a GPRS based power cable grounding wire anti-theft monitoring device system, which includes a camera module, a sensor module, a micro processing system module, and a data monitoring center module, a mobile terminal module. Our design utilize two kinds of methods for detecting and reporting comprehensive image, it can effectively solve the problem of power and cable grounding wire box theft problem, timely follow-up grounded cable theft events, prevent the occurrence of electric field of high voltage transmission line fault, improve the reliability of the safe operation of power grid.

  7. Statistical Model Checking of Rich Models and Properties

    DEFF Research Database (Denmark)

    Poulsen, Danny Bøgsted

    in undecidability issues for the traditional model checking approaches. Statistical model checking has proven itself a valuable supplement to model checking and this thesis is concerned with extending this software validation technique to stochastic hybrid systems. The thesis consists of two parts: the first part...... motivates why existing model checking technology should be supplemented by new techniques. It also contains a brief introduction to probability theory and concepts covered by the six papers making up the second part. The first two papers are concerned with developing online monitoring techniques...... systems. The fifth paper shows how stochastic hybrid automata are useful for modelling biological systems and the final paper is concerned with showing how statistical model checking is efficiently distributed. In parallel with developing the theory contained in the papers, a substantial part of this work...

  8. UTP and Temporal Logic Model Checking

    Science.gov (United States)

    Anderson, Hugh; Ciobanu, Gabriel; Freitas, Leo

    In this paper we give an additional perspective to the formal verification of programs through temporal logic model checking, which uses Hoare and He Unifying Theories of Programming (UTP). Our perspective emphasizes the use of UTP designs, an alphabetised relational calculus expressed as a pre/post condition pair of relations, to verify state or temporal assertions about programs. The temporal model checking relation is derived from a satisfaction relation between the model and its properties. The contribution of this paper is that it shows a UTP perspective to temporal logic model checking. The approach includes the notion of efficiency found in traditional model checkers, which reduced a state explosion problem through the use of efficient data structures

  9. Coverage Metrics for Model Checking

    Science.gov (United States)

    Penix, John; Visser, Willem; Norvig, Peter (Technical Monitor)

    2001-01-01

    When using model checking to verify programs in practice, it is not usually possible to achieve complete coverage of the system. In this position paper we describe ongoing research within the Automated Software Engineering group at NASA Ames on the use of test coverage metrics to measure partial coverage and provide heuristic guidance for program model checking. We are specifically interested in applying and developing coverage metrics for concurrent programs that might be used to support certification of next generation avionics software.

  10. First experiences with the LHC BLM sanity checks

    Science.gov (United States)

    Emery, J.; Dehning, B.; Effinger, E.; Nordt, A.; Sapinski, M. G.; Zamantzas, C.

    2010-12-01

    The reliability concerns have driven the design of the Large Hardron Collider (LHC) Beam Loss Monitoring (BLM) system from the early stage of the studies up to the present commissioning and the latest development of diagnostic tools. To protect the system against non-conformities, new ways of automatic checking have been developed and implemented. These checks are regularly and systematically executed by the LHC operation team to ensure that the system status is after each test "as good as new". The sanity checks are part of this strategy. They are testing the electrical part of the detectors (ionisation chamber or secondary emission detector), their cable connections to the front-end electronics, further connections to the back-end electronics and their ability to request a beam abort. During the installation and in the early commissioning phase, these checks have shown their ability to find also non-conformities caused by unexpected failure event scenarios. In every day operation, a non-conformity discovered by this check inhibits any further injections into the LHC until the check confirms the absence of non-conformities.

  11. First experiences with the LHC BLM sanity checks

    International Nuclear Information System (INIS)

    Emery, J; Dehning, B; Effinger, E; Nordt, A; Sapinski, M G; Zamantzas, C

    2010-01-01

    The reliability concerns have driven the design of the Large Hardron Collider (LHC) Beam Loss Monitoring (BLM) system from the early stage of the studies up to the present commissioning and the latest development of diagnostic tools. To protect the system against non-conformities, new ways of automatic checking have been developed and implemented. These checks are regularly and systematically executed by the LHC operation team to ensure that the system status is after each test a s good as new . The sanity checks are part of this strategy. They are testing the electrical part of the detectors (ionisation chamber or secondary emission detector), their cable connections to the front-end electronics, further connections to the back-end electronics and their ability to request a beam abort. During the installation and in the early commissioning phase, these checks have shown their ability to find also non-conformities caused by unexpected failure event scenarios. In every day operation, a non-conformity discovered by this check inhibits any further injections into the LHC until the check confirms the absence of non-conformities.

  12. First experiences with the LHC BLM sanity checks

    Energy Technology Data Exchange (ETDEWEB)

    Emery, J; Dehning, B; Effinger, E; Nordt, A; Sapinski, M G; Zamantzas, C, E-mail: Jonathan.emery@cern.ch [CERN, CH-1211 Geneve 23 (Switzerland)

    2010-12-15

    The reliability concerns have driven the design of the Large Hardron Collider (LHC) Beam Loss Monitoring (BLM) system from the early stage of the studies up to the present commissioning and the latest development of diagnostic tools. To protect the system against non-conformities, new ways of automatic checking have been developed and implemented. These checks are regularly and systematically executed by the LHC operation team to ensure that the system status is after each test {sup a}s good as new{sup .} The sanity checks are part of this strategy. They are testing the electrical part of the detectors (ionisation chamber or secondary emission detector), their cable connections to the front-end electronics, further connections to the back-end electronics and their ability to request a beam abort. During the installation and in the early commissioning phase, these checks have shown their ability to find also non-conformities caused by unexpected failure event scenarios. In every day operation, a non-conformity discovered by this check inhibits any further injections into the LHC until the check confirms the absence of non-conformities.

  13. Content Validation and Semantic Evaluation of a Check-List Elaborated for the Prevention of Gluten Cross-Contamination in Food Services

    Directory of Open Access Journals (Sweden)

    Priscila Farage

    2017-01-01

    Full Text Available Conditions associated to the consumption of gluten have emerged as a major health care concern and the treatment consists on a lifelong gluten-free diet. Providing safe food for these individuals includes adapting to safety procedures within the food chain and preventing gluten cross-contamination in gluten-free food. However, a gluten cross-contamination prevention protocol or check-list has not yet been validated. Therefore, the aim of this study was to perform the content validation and semantic evaluation of a check-list elaborated for the prevention of gluten cross-contamination in food services. The preliminary version of the check-list was elaborated based on the Brazilian resolution for food safety Collegiate Board Resolution 216 (RDC 216 and Collegiate Board Resolution 275 (RDC 275, the standard 22000 from the International Organization for Standardization (ISO 22000 and the Canadian Celiac Association Gluten-Free Certification Program documents. Seven experts with experience in the area participated in the check-list validation and semantic evaluation. The criteria used for the approval of the items, as to their importance for the prevention of gluten cross-contamination and clarity of the wording, was the achievement of a minimal of 80% of agreement between the experts (W-values ≥ 0.8. Moreover, items should have a mean ≥4 in the evaluation of importance (Likert scale from 1 to 5 and clarity (Likert scale from 0 to 5 in order to be maintained in the instrument. The final version of the check-list was composed of 84 items, divided into 12 sections. After being redesigned and re-evaluated, the items were considered important and comprehensive by the experts (both with W-values ≥ 0.89. The check-list developed was validated with respect to content and approved in the semantic evaluation.

  14. Content Validation and Semantic Evaluation of a Check-List Elaborated for the Prevention of Gluten Cross-Contamination in Food Services.

    Science.gov (United States)

    Farage, Priscila; Puppin Zandonadi, Renata; Cortez Ginani, Verônica; Gandolfi, Lenora; Pratesi, Riccardo; de Medeiros Nóbrega, Yanna Karla

    2017-01-06

    Conditions associated to the consumption of gluten have emerged as a major health care concern and the treatment consists on a lifelong gluten-free diet. Providing safe food for these individuals includes adapting to safety procedures within the food chain and preventing gluten cross-contamination in gluten-free food. However, a gluten cross-contamination prevention protocol or check-list has not yet been validated. Therefore, the aim of this study was to perform the content validation and semantic evaluation of a check-list elaborated for the prevention of gluten cross-contamination in food services. The preliminary version of the check-list was elaborated based on the Brazilian resolution for food safety Collegiate Board Resolution 216 (RDC 216) and Collegiate Board Resolution 275 (RDC 275), the standard 22000 from the International Organization for Standardization (ISO 22000) and the Canadian Celiac Association Gluten-Free Certification Program documents. Seven experts with experience in the area participated in the check-list validation and semantic evaluation. The criteria used for the approval of the items, as to their importance for the prevention of gluten cross-contamination and clarity of the wording, was the achievement of a minimal of 80% of agreement between the experts (W-values ≥ 0.8). Moreover, items should have a mean ≥4 in the evaluation of importance (Likert scale from 1 to 5) and clarity (Likert scale from 0 to 5) in order to be maintained in the instrument. The final version of the check-list was composed of 84 items, divided into 12 sections. After being redesigned and re-evaluated, the items were considered important and comprehensive by the experts (both with W-values ≥ 0.89). The check-list developed was validated with respect to content and approved in the semantic evaluation.

  15. Do alcohol compliance checks decrease underage sales at neighboring establishments?

    Science.gov (United States)

    Erickson, Darin J; Smolenski, Derek J; Toomey, Traci L; Carlin, Bradley P; Wagenaar, Alexander C

    2013-11-01

    Underage alcohol compliance checks conducted by law enforcement agencies can reduce the likelihood of illegal alcohol sales at checked alcohol establishments, and theory suggests that an alcohol establishment that is checked may warn nearby establishments that compliance checks are being conducted in the area. In this study, we examined whether the effects of compliance checks diffuse to neighboring establishments. We used data from the Complying with the Minimum Drinking Age trial, which included more than 2,000 compliance checks conducted at more than 900 alcohol establishments. The primary outcome was the sale of alcohol to a pseudo-underage buyer without the need for age identification. A multilevel logistic regression was used to model the effect of a compliance check at each establishment as well as the effect of compliance checks at neighboring establishments within 500 m (stratified into four equal-radius concentric rings), after buyer, license, establishment, and community-level variables were controlled for. We observed a decrease in the likelihood of establishments selling alcohol to underage youth after they had been checked by law enforcement, but these effects quickly decayed over time. Establishments that had a close neighbor (within 125 m) checked in the past 90 days were also less likely to sell alcohol to young-appearing buyers. The spatial effect of compliance checks on other establishments decayed rapidly with increasing distance. Results confirm the hypothesis that the effects of police compliance checks do spill over to neighboring establishments. These findings have implications for the development of an optimal schedule of police compliance checks.

  16. Unmanned Aerial Systems Traffic Management (UTM): Safely Enabling UAS Operations in Low-Altitude Airspace

    Science.gov (United States)

    Jung, Jaewoo; Kopardekar, Parimal H.

    2016-01-01

    Flexibility where possible, and structure where necessary. Consider the needs of national security, safe airspace operations, economic opportunities, and emerging technologies. Risk-based approach based on population density, assets on the ground, density of operations, etc. Digital, virtual, dynamic, and as needed UTM services to manage operations.

  17. Checking and Balancing: Banking and Budgeting.

    Science.gov (United States)

    Thypin, Marilyn; Glasner, Lynne

    A short fictional work for limited English speakers is presented that relates a young couple's experience in learning about managing their money more carefully by budgeting and maintaining a checking account. Since the couple did not have a checking account, they had to go to their savings bank in order to pay each bill and they had to keep cash…

  18. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  19. Glovebox pressure relief and check valve

    International Nuclear Information System (INIS)

    Blaedel, K.L.

    1986-01-01

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury

  20. 76 FR 12719 - Safe Schools/Healthy Students Program; Office of Safe and Drug-Free Schools; Safe Schools/Healthy...

    Science.gov (United States)

    2011-03-08

    ... DEPARTMENT OF EDUCATION Safe Schools/Healthy Students Program; Office of Safe and Drug- Free Schools; Safe Schools/Healthy Students Program; Catalog of Federal Domestic Assistance (CFDA) Numbers: 84... priorities, requirements, and definitions under the Safe Schools/Healthy Students (SS/HS) program. Since...

  1. Underside corrosion of above ground storage tanks (ASTs) | Rim ...

    African Journals Online (AJOL)

    ... above statutory safe limits. The results showed that the physico-chemical characteristics of the water sample have diagnostic and predictive values to implicate and promote underside corrosion of the studied above ground storage tank. Journal of Applied Sciences and Environmental Management Vol. 9(1) 2005: 161-163.

  2. Repeated checking induces uncertainty about future threat

    NARCIS (Netherlands)

    Giele, C.L.|info:eu-repo/dai/nl/318754460; Engelhard, I.M.|info:eu-repo/dai/nl/239681533; van den Hout, M.A.|info:eu-repo/dai/nl/070445354; Dek, E.C.P.|info:eu-repo/dai/nl/313959552; Damstra, Marianne; Douma, Ellen

    2015-01-01

    Studies have shown that obsessive-compulsive (OC) -like repeated checking paradoxically increases memory uncertainty. This study tested if checking also induces uncertainty about future threat by impairing the distinction between danger and safety cues. Participants (n = 54) engaged in a simulated

  3. Inkjet 3D printed check microvalve

    International Nuclear Information System (INIS)

    Walczak, Rafał; Adamski, Krzysztof; Lizanets, Danylo

    2017-01-01

    3D printing enables fast and relatively easy fabrication of various microfluidic structures including microvalves. A check microvalve is the simplest valve enabling control of the fluid flow in microchannels. Proper operation of the check valve is ensured by a movable element that tightens the valve seat during backward flow and enables free flow for forward pressure. Thus, knowledge of the mechanical properties of the movable element is crucial for optimal design and operation of the valve. In this paper, we present for the first time the results of investigations on basic mechanical properties of the building material used in multijet 3D printing. Specified mechanical properties were used in the design and fabrication of two types of check microvalve—with deflecting or hinge-fixed microflap—with 200 µ m and 300 µ m thickness. Results of numerical simulation and experimental data of the microflap deflection were obtained and compared. The valves were successfully 3D printed and characterised. Opening/closing characteristics of the microvalve for forward and backward pressures were determined. Thus, proper operation of the check microvalve so developed was confirmed. (technical note)

  4. Purification of arsenic contaminated ground water using hydrated manganese dioxide

    International Nuclear Information System (INIS)

    Raje, N.; Swain, K.K.

    2002-01-01

    An analytical methodology has been developed for the separation of arsenic from ground water using inorganic material in neutral medium. The separation procedure involves the quantitative retention of arsenic on hydrated manganese dioxide, in neutral medium. The validity of the separation procedure has been checked by a standard addition method and radiotracer studies. Neutron activation analysis (NAA), a powerful measurement technique, has been used for the quantitative determination of arsenic. (author)

  5. Systematic Review of the Check-In, Check-Out Intervention for Students at Risk for Emotional and Behavioral Disorders

    Science.gov (United States)

    Hawken, Leanne S.; Bundock, Kaitlin; Kladis, Kristin; O'Keeffe, Breda; Barret, Courtenay A.

    2014-01-01

    The purpose of this systematic literature review was to summarize outcomes of the Check-in Check-out (CICO) intervention across elementary and secondary settings. Twenty-eight studies utilizing both single subject and group (experimental and quasi-experimental) designs were included in this review. Median effect sizes across the eight group…

  6. Estimate of safe human exposure levels for lunar dust based on comparative benchmark dose modeling.

    Science.gov (United States)

    James, John T; Lam, Chiu-Wing; Santana, Patricia A; Scully, Robert R

    2013-04-01

    Brief exposures of Apollo astronauts to lunar dust occasionally elicited upper respiratory irritation; however, no limits were ever set for prolonged exposure to lunar dust. The United States and other space faring nations intend to return to the moon for extensive exploration within a few decades. In the meantime, habitats for that exploration, whether mobile or fixed, must be designed to limit human exposure to lunar dust to safe levels. Herein we estimate safe exposure limits for lunar dust collected during the Apollo 14 mission. We instilled three respirable-sized (∼2 μ mass median diameter) lunar dusts (two ground and one unground) and two standard dusts of widely different toxicities (quartz and TiO₂) into the respiratory system of rats. Rats in groups of six were given 0, 1, 2.5 or 7.5 mg of the test dust in a saline-Survanta® vehicle, and biochemical and cellular biomarkers of toxicity in lung lavage fluid were assayed 1 week and one month after instillation. By comparing the dose--response curves of sensitive biomarkers, we estimated safe exposure levels for astronauts and concluded that unground lunar dust and dust ground by two different methods were not toxicologically distinguishable. The safe exposure estimates were 1.3 ± 0.4 mg/m³ (jet-milled dust), 1.0 ± 0.5 mg/m³ (ball-milled dust) and 0.9 ± 0.3 mg/m³ (unground, natural dust). We estimate that 0.5-1 mg/m³ of lunar dust is safe for periodic human exposures during long stays in habitats on the lunar surface.

  7. Web-based ground loop supervision system for the TJ-II Stellarator

    International Nuclear Information System (INIS)

    Pena, A. de la; Lapayese, F.; Pacios, L.; Carrasco, R.

    2005-01-01

    To minimize electromagnetic interferences in diagnostic and control signals, and to guarantee safe operation of TJ-II, ground loops must be avoided. In order to meet this goal, the whole grounding system of the TJ-II was split into multiple single branches that are connected at a single earth point located near the TJ-II structure in the torus hall. A real-time ground loop supervision system (GLSS) has been designed, manufactured and tested by the TJ-II control group for detecting unintentional short circuits between isolated grounded parts. A web server running on the real-time operating system OS-9 provides remote access to the real-time ground loops measurement. Ground loops monitoring and different operation modes can be configured via any web browser. This paper gives the detailed design of the whole TJ-II ground loop supervision system and its results during its operation

  8. Web-based ground loop supervision system for the TJ-II Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Pena, A. de la [Asociacion EURATOM-CIEMAT Para Fusion, Avd. Complutense 22, 28040 Madrid (Spain)]. E-mail: a.delapena@ciemat.es; Lapayese, F. [Asociacion EURATOM-CIEMAT Para Fusion, Avd. Complutense 22, 28040 Madrid (Spain); Pacios, L. [Asociacion EURATOM-CIEMAT Para Fusion, Avd. Complutense 22, 28040 Madrid (Spain); Carrasco, R. [Asociacion EURATOM-CIEMAT Para Fusion, Avd. Complutense 22, 28040 Madrid (Spain)

    2005-11-15

    To minimize electromagnetic interferences in diagnostic and control signals, and to guarantee safe operation of TJ-II, ground loops must be avoided. In order to meet this goal, the whole grounding system of the TJ-II was split into multiple single branches that are connected at a single earth point located near the TJ-II structure in the torus hall. A real-time ground loop supervision system (GLSS) has been designed, manufactured and tested by the TJ-II control group for detecting unintentional short circuits between isolated grounded parts. A web server running on the real-time operating system OS-9 provides remote access to the real-time ground loops measurement. Ground loops monitoring and different operation modes can be configured via any web browser. This paper gives the detailed design of the whole TJ-II ground loop supervision system and its results during its operation.

  9. Next-generation nozzle check valve significantly reduces operating costs

    Energy Technology Data Exchange (ETDEWEB)

    Roorda, O. [SMX International, Toronto, ON (Canada)

    2009-01-15

    Check valves perform an important function in preventing reverse flow and protecting plant and mechanical equipment. However, the variety of different types of valves and extreme differences in performance even within one type can change maintenance requirements and life cycle costs, amounting to millions of dollars over the typical 15-year design life of piping components. A next-generation non-slam nozzle check valve which prevents return flow has greatly reduced operating costs by protecting the mechanical equipment in a piping system. This article described the check valve varieties such as the swing check valve, a dual-plate check valve, and nozzle check valves. Advancements in optimized design of a non-slam nozzle check valve were also discussed, with particular reference to computer flow modelling such as computational fluid dynamics; computer stress modelling such as finite element analysis; and flow testing (using rapid prototype development and flow loop testing), both to improve dynamic performance and reduce hydraulic losses. The benefits of maximized dynamic performance and minimized pressure loss from the new designed valve were also outlined. It was concluded that this latest non-slam nozzle check valve design has potential applications in natural gas, liquefied natural gas, and oil pipelines, including subsea applications, as well as refineries, and petrochemical plants among others, and is suitable for horizontal and vertical installation. The result of this next-generation nozzle check valve design is not only superior performance, and effective protection of mechanical equipment but also minimized life cycle costs. 1 fig.

  10. Principle and opening-closing character analysis of DC check valve

    International Nuclear Information System (INIS)

    Han Xu; Zhou Yu

    2006-01-01

    When the behaviour of main pump in PWR power plant change, as a result of arresting fluid countercurrent current by check valve, water hammer phenomena met occur more or less in loop. Serious water hammer not only met brought incident of over pressure, imperil pressure boundary, but also may engender check valve lapse. DC check valve is a kind of new theory check valve, is designed to avoid serious water hammer phenomena at tradition check valve closing, the analyses and experiment indicate that DC check valve can availably solve water hammer problem in the loop, and be able to reliably prevent fluid countercurrent. (authors)

  11. Shallow ground disposal of radioactive wastes

    International Nuclear Information System (INIS)

    1981-01-01

    This guidebook outlines the factors to be considered in site selection, design, operation, shut-down and surveillance as well as the regulatory requirements of repositories for safe disposal of radioactive waste in shallow ground. No attempt is made to summarize the existing voluminous literature on the many facets of radioactive waste disposal. In the context of this guidebook, shallow ground disposal refers to the emplacement of radioactive waste, with or without engineered barriers, above or below the ground surface, where the final protective covering is of the order of a few metres thick. Deep geological disposal and other underground disposal methods, management of mill tailings and disposal into the sea have been or will be considered in other IAEA publications. These guidelines have been made sufficiently general to cover a broad variety of climatic, hydrogeological and biological conditions. They may need to be interpreted or modified to reflect local conditions and national regulations

  12. The use of check valve performance data to support new concepts (probabilistic risk assessment, condition monitoring) for check valve program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.; Gower, D.

    1996-12-01

    The concept of developing an integrated check valve database based on the Nuclear Power Reliability Data System (NPRDS) data was presented at the last Symposium. The Nuclear Industry Check Valve Group (NIC), working in cooperation with the Oak Ridge National Laboratory (ORNL), has completed an operational database of check valve performance from 1984 to the present. NIC has committed to the nuclear industry to periodically update the data and maintain this information accessible. As the new concepts of probabilistic risk analysis and condition monitoring are integrated into the American Society of Mechanical Engineers (ASME) Code, a critical element will be performance data. From check valve performance data, feasible failure modes and rates can be established. When a failure rate or frequency of failures can be established based on a significant enough population (sampling), a more solid foundation for focusing resources and determining appropriate frequencies and testing can be determined. The presentation will give the updated status of the NIC Check Valve Performance Database covering (1) methodology used to combine the original ORNL data; (2) process/controls established for continuing update and refinement of the data; (3) discussion of how this data is being utilized by (a) OM-22 for condition monitoring, and (b) risk-based inservice testing work of Westinghouse Owners` Group; and (4) results/trends of data evaluations. At the 1994 Symposium, ORNL provided an update as of 1991 to their original work of 1984 -1990 which they had performed to characterize check valve degradations and failures in the nuclear industry. These characterizations will be updated to 1995 and additional reviews provided to give insight into the current condition and trends of check valve performance.

  13. The use of check valve performance data to support new concepts (probabilistic risk assessment, condition monitoring) for check valve program

    International Nuclear Information System (INIS)

    Hart, K.A.; Gower, D.

    1996-01-01

    The concept of developing an integrated check valve database based on the Nuclear Power Reliability Data System (NPRDS) data was presented at the last Symposium. The Nuclear Industry Check Valve Group (NIC), working in cooperation with the Oak Ridge National Laboratory (ORNL), has completed an operational database of check valve performance from 1984 to the present. NIC has committed to the nuclear industry to periodically update the data and maintain this information accessible. As the new concepts of probabilistic risk analysis and condition monitoring are integrated into the American Society of Mechanical Engineers (ASME) Code, a critical element will be performance data. From check valve performance data, feasible failure modes and rates can be established. When a failure rate or frequency of failures can be established based on a significant enough population (sampling), a more solid foundation for focusing resources and determining appropriate frequencies and testing can be determined. The presentation will give the updated status of the NIC Check Valve Performance Database covering (1) methodology used to combine the original ORNL data; (2) process/controls established for continuing update and refinement of the data; (3) discussion of how this data is being utilized by (a) OM-22 for condition monitoring, and (b) risk-based inservice testing work of Westinghouse Owners' Group; and (4) results/trends of data evaluations. At the 1994 Symposium, ORNL provided an update as of 1991 to their original work of 1984 -1990 which they had performed to characterize check valve degradations and failures in the nuclear industry. These characterizations will be updated to 1995 and additional reviews provided to give insight into the current condition and trends of check valve performance

  14. Cool and Safe: Multiplicity in Safe Innovation at Unilever

    Science.gov (United States)

    Penders, Bart

    2011-01-01

    This article presents the making of a safe innovation: the application of ice structuring protein (ISP) in edible ices. It argues that safety is not the absence of risk but is an active accomplishment; innovations are not "made safe afterward" but "safe innovations are made". Furthermore, there are multiple safeties to be accomplished in the…

  15. Partial-order reduction for GPU model checking

    NARCIS (Netherlands)

    Neele, T.S.; Wijs, A.J.; Bošnački, D.; van de Pol, J.C.

    2016-01-01

    Model checking using GPUs has seen increased popularity over the last years. Because GPUs have a limited amount of memory, only small to medium-sized systems can be verified. For on-the-fly explicitstate model checking, we improve memory efficiency by applying partialorder reduction. We propose

  16. 40 CFR 89.317 - NOX converter check.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false NOX converter check. 89.317 Section 89.317 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED..., the chemiluminescent oxides of nitrogen analyzer shall be checked for NO2 to NO converter efficiency...

  17. Assessment of check-dam groundwater recharge with water-balance calculations

    Science.gov (United States)

    Djuma, Hakan; Bruggeman, Adriana; Camera, Corrado; Eliades, Marinos

    2017-04-01

    Studies on the enhancement of groundwater recharge by check-dams in arid and semi-arid environments mainly focus on deriving water infiltration rates from the check-dam ponding areas. This is usually achieved by applying simple water balance models, more advanced models (e.g., two dimensional groundwater models) and field tests (e.g., infiltrometer test or soil pit tests). Recharge behind the check-dam can be affected by the built-up of sediment as a result of erosion in the upstream watershed area. This natural process can increase the uncertainty in the estimates of the recharged water volume, especially for water balance calculations. Few water balance field studies of individual check-dams have been presented in the literature and none of them presented associated uncertainties of their estimates. The objectives of this study are i) to assess the effect of a check-dam on groundwater recharge from an ephemeral river; and ii) to assess annual sedimentation at the check-dam during a 4-year period. The study was conducted on a check-dam in the semi-arid island of Cyprus. Field campaigns were carried out to measure water flow, water depth and check-dam topography in order to establish check-dam water height, volume, evaporation, outflow and recharge relations. Topographic surveys were repeated at the end of consecutive hydrological years to estimate the sediment built up in the reservoir area of the check dam. Also, sediment samples were collected from the check-dam reservoir area for bulk-density analyses. To quantify the groundwater recharge, a water balance model was applied at two locations: at the check-dam and corresponding reservoir area, and at a 4-km stretch of the river bed without check-dam. Results showed that a check-dam with a storage capacity of 25,000 m3 was able to recharge to the aquifer, in four years, a total of 12 million m3 out of the 42 million m3 of measured (or modelled) streamflow. Recharge from the analyzed 4-km long river section without

  18. Weather radar performance monitoring using a metallic-grid ground-scatterer

    Science.gov (United States)

    Falconi, Marta Tecla; Montopoli, Mario; Marzano, Frank Silvio; Baldini, Luca

    2017-10-01

    The use of ground return signals is investigated for checks on the calibration of power measurements of a polarimetric C-band radar. To this aim, a peculiar permanent single scatterer (PSS) consisting of a big metallic roof with a periodic mesh grid structure and having a hemisphere-like shape is considered. The latter is positioned in the near-field region of the weather radar and its use, as a reference calibrator, shows fairly good results in terms of reflectivity and differential reflectivity monitoring. In addition, the use of PSS indirectly allows to check for the radar antenna de-pointing which is another issue usually underestimated when dealing with weather radars. Because of the periodic structure of the considered PSS, simulations of its electromagnetic behavior were relatively easy to perform. To this goal, we used an electromagnetic Computer-Aided-Design (CAD) with an ad-hoc numerical implementation of a full-wave solution to model our PSS in terms of reflectivity and differential reflectivity factor. Comparison of model results and experimental measurements are then shown in this work. Our preliminary investigation can pave the way for future studies aiming at characterizing ground-clutter returns in a more accurate way for radar calibration purposes.

  19. AUTOMATED HOTEL CHECK-IN SERTA DAMPAKNYA PADA TENAGA KERJA LOKAL

    Directory of Open Access Journals (Sweden)

    Ni Gusti Nyoman Suci Murni

    2017-10-01

    Full Text Available The tourism sector is one of the most heavily influenced sectors of information technology. Hotels that are a component of tourism cannot be separated from these influences, especially in information services, room reservations, check-in / check-out service, and other services. With the sophistication of information technology, everyone can access any information, from anywhere; at a very cheap price even every country provides free facilities for that purpose. This study uses qualitative methods where the data source obtained by looking for some libraries related to self check-in. The results show that there are some differences that applied between the check-in manual and self check-in, and the impact caused by the application of self check-in. The positive impact of self check-in are speeding up the check-in process, saving payrolls, simplifying services, simplifying reporting, and saving time. While the negative impacts such as reducing employment in developing countries, reducing social communication / human touch, reducing the understanding of cross cultural understanding, allowing the occurrence of crime (cyber crime as well as very expensive initial cost.

  20. Ground engineering principles and practices for underground coal mining

    CERN Document Server

    Galvin, J M

    2016-01-01

    This book teaches readers ground engineering principles and related mining and risk management practices associated with underground coal mining. It establishes the basic elements of risk management and the fundamental principles of ground behaviour and then applies these to the essential building blocks of any underground coal mining system, comprising excavations, pillars, and interactions between workings. Readers will also learn about types of ground support and reinforcement systems and their operating mechanisms. These elements provide the platform whereby the principles can be applied to mining practice and risk management, directed primarily to bord and pillar mining, pillar extraction, longwall mining, sub-surface and surface subsidence, and operational hazards. The text concludes by presenting the framework of risk-based ground control management systems for achieving safe workplaces and efficient mining operations. In addition, a comprehensive reference list provides additional sources of informati...

  1. SPEED ROLLER STAND MEASUREMENT SYSTEM CHECKING TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Y. Zybtsev

    2011-01-01

    Full Text Available The study has shown that the accuracy of brakes checking by inertial stands depends upon the applied methods of measurement of braking parameters (stand slowing down, braking distance, brakes triggering time, current speed as well as the methods of metrological checking of measuring system canals.

  2. Partial-Order Reduction for GPU Model Checking

    NARCIS (Netherlands)

    Neele, T.; Wijs, A.; Bosnacki, D.; van de Pol, Jan Cornelis; Artho, C; Legay, A.; Peled, D.

    2016-01-01

    Model checking using GPUs has seen increased popularity over the last years. Because GPUs have a limited amount of memory, only small to medium-sized systems can be verified. For on-the-fly explicit-state model checking, we improve memory efficiency by applying partial-order reduction. We propose

  3. TARDEC Overview: Ground Vehicle Power and Mobility

    Science.gov (United States)

    2011-02-04

    Fuel & Water Distribution • Force Sustainment • Construction Equipment • Bridging • Assured Mobility Systems Robotics • TALON • PackBot • MARCbot...Equipment • Mechanical Countermine Equipment • Tactical Bridging Intelligent Ground Systems • Autonomous Robotics Systems • Safe Operations...Test Cell • Hybrid Electric Reconfigurable Moveable Integration Testbed (HERMIT) • Electro-chemical Analysis and Research Lab (EARL) • Battery Lab • Air

  4. 40 CFR 86.327-79 - Quench checks; NOX analyzer.

    Science.gov (United States)

    2010-07-01

    ... any flow rate into the reaction chamber. This includes, but is not limited to, sample capillary, ozone... Quench checks; NOX analyzer. (a) Perform the reaction chamber quench check for each model of high vacuum reaction chamber analyzer prior to initial use. (b) Perform the reaction chamber quench check for each new...

  5. Grounding for safety

    Energy Technology Data Exchange (ETDEWEB)

    Prud' homme, P. [Hydro-Quebec, Montreal, PQ (Canada). TransEnergie Div.

    2006-07-01

    The importance of providing electrical grounds as a safety issue in the design of power transmission lines was discussed. Power transmission lines extend over several thousands of kilometers crossing various environments, including communities where electric utilities encourage the use of transmission rights-of-way passages for uses such as bicycle paths. In recent years, many new residential communities have been built at the border of power transmission rights-of-ways or substations. In view of this emerging trend, and the fact that internal statistics indicate that lightning strikes are responsible of about 50 to 60 per cent of transmission line faults, electric utilities are obligated to verify if their installations are safe. Hydro-Quebec TransEnergie's view on this subject was presented along with a review of international standards to determine if limits for touch voltage, step voltage and transferred potential close to transmission lines have been established by the international community. A variety of mitigation measures to control the increase in ground potential in the event of electrical faults were also proposed. tabs., figs.

  6. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  7. Engineering Abstractions in Model Checking and Testing

    DEFF Research Database (Denmark)

    Achenbach, Michael; Ostermann, Klaus

    2009-01-01

    Abstractions are used in model checking to tackle problems like state space explosion or modeling of IO. The application of these abstractions in real software development processes, however, lacks engineering support. This is one reason why model checking is not widely used in practice yet...... and testing is still state of the art in falsification. We show how user-defined abstractions can be integrated into a Java PathFinder setting with tools like AspectJ or Javassist and discuss implications of remaining weaknesses of these tools. We believe that a principled engineering approach to designing...... and implementing abstractions will improve the applicability of model checking in practice....

  8. 12 CFR 229.36 - Presentment and issuance of checks.

    Science.gov (United States)

    2010-01-01

    ... Section 229.36 Banks and Banking FEDERAL RESERVE SYSTEM (CONTINUED) BOARD OF GOVERNORS OF THE FEDERAL RESERVE SYSTEM AVAILABILITY OF FUNDS AND COLLECTION OF CHECKS (REGULATION CC) Collection of Checks § 229... on the check, whether in magnetic ink or in fractional form; (3) At any branch or head office, if the...

  9. FIZCON, ENDF/B Cross-Sections Redundancy Check

    International Nuclear Information System (INIS)

    Dunford, Charles L.

    2007-01-01

    1 - Description of program or function: FIZCON is a program for checking that an evaluated data file has valid data and conforms to recommended procedures. Version 7.01 (April 2005): set success flag after return from beginning; fixed valid level check for an isomer; fixed subsection energy range test in ckf9; changed lower limit on potential scattering test; fixed error in j-value test when l=0 and i=0; added one more significant figure to union grid check and sum up output messages; partial fission cross sections mt=19,20,21 and 38 did not require secondary energy distributions in file 5; corrected product test for elastic scattering; moved potential scattering test to psyche. Version 7.02 (May 2005): Fixed resonance parameter sum test. 2 - Method of solution: FIZCON can recognise the difference between ENDF-6 and ENDF-5 formats and performs its tests accordingly. Some of the tests performed include: data arrays are in increasing energy order; resonance parameter widths add up to the total; Q-values are reasonable and consistent; no required sections are missing and all cover the proper energy range; secondary distributions are normalized to 1.0; energy conservation in decay spectra. Optional tests can be performed to check the redundant cross sections, and algorithms can be used to check for possible incorrect entry of data values (Deviant Point test)

  10. [Memory Checking Tests].

    Science.gov (United States)

    Hart, Joseph T.

    Two basic tests for checking memory skills are included in these appendices. The first, the General Information Test, uses the same 150 items for each of its two versions. One version is a completion-type test which measures recall by requiring the examinee to supply a specific response. The other version supplements each of the 150 items with…

  11. Check Sample Abstracts.

    Science.gov (United States)

    Alter, David; Grenache, David G; Bosler, David S; Karcher, Raymond E; Nichols, James; Rajadhyaksha, Aparna; Camelo-Piragua, Sandra; Rauch, Carol; Huddleston, Brent J; Frank, Elizabeth L; Sluss, Patrick M; Lewandrowski, Kent; Eichhorn, John H; Hall, Janet E; Rahman, Saud S; McPherson, Richard A; Kiechle, Frederick L; Hammett-Stabler, Catherine; Pierce, Kristin A; Kloehn, Erica A; Thomas, Patricia A; Walts, Ann E; Madan, Rashna; Schlesinger, Kathie; Nawgiri, Ranjana; Bhutani, Manoop; Kanber, Yonca; Abati, Andrea; Atkins, Kristen A; Farrar, Robert; Gopez, Evelyn Valencerina; Jhala, Darshana; Griffin, Sonya; Jhala, Khushboo; Jhala, Nirag; Bentz, Joel S; Emerson, Lyska; Chadwick, Barbara E; Barroeta, Julieta E; Baloch, Zubair W; Collins, Brian T; Middleton, Owen L; Davis, Gregory G; Haden-Pinneri, Kathryn; Chu, Albert Y; Keylock, Joren B; Ramoso, Robert; Thoene, Cynthia A; Stewart, Donna; Pierce, Arand; Barry, Michelle; Aljinovic, Nika; Gardner, David L; Barry, Michelle; Shields, Lisa B E; Arnold, Jack; Stewart, Donna; Martin, Erica L; Rakow, Rex J; Paddock, Christopher; Zaki, Sherif R; Prahlow, Joseph A; Stewart, Donna; Shields, Lisa B E; Rolf, Cristin M; Falzon, Andrew L; Hudacki, Rachel; Mazzella, Fermina M; Bethel, Melissa; Zarrin-Khameh, Neda; Gresik, M Vicky; Gill, Ryan; Karlon, William; Etzell, Joan; Deftos, Michael; Karlon, William J; Etzell, Joan E; Wang, Endi; Lu, Chuanyi M; Manion, Elizabeth; Rosenthal, Nancy; Wang, Endi; Lu, Chuanyi M; Tang, Patrick; Petric, Martin; Schade, Andrew E; Hall, Geraldine S; Oethinger, Margret; Hall, Geraldine; Picton, Avis R; Hoang, Linda; Imperial, Miguel Ranoa; Kibsey, Pamela; Waites, Ken; Duffy, Lynn; Hall, Geraldine S; Salangsang, Jo-Anne M; Bravo, Lulette Tricia C; Oethinger, Margaret D; Veras, Emanuela; Silva, Elvia; Vicens, Jimena; Silva, Elvio; Keylock, Joren; Hempel, James; Rushing, Elizabeth; Posligua, Lorena E; Deavers, Michael T; Nash, Jason W; Basturk, Olca; Perle, Mary Ann; Greco, Alba; Lee, Peng; Maru, Dipen; Weydert, Jamie Allen; Stevens, Todd M; Brownlee, Noel A; Kemper, April E; Williams, H James; Oliverio, Brock J; Al-Agha, Osama M; Eskue, Kyle L; Newlands, Shawn D; Eltorky, Mahmoud A; Puri, Puja K; Royer, Michael C; Rush, Walter L; Tavora, Fabio; Galvin, Jeffrey R; Franks, Teri J; Carter, James Elliot; Kahn, Andrea Graciela; Lozada Muñoz, Luis R; Houghton, Dan; Land, Kevin J; Nester, Theresa; Gildea, Jacob; Lefkowitz, Jerry; Lacount, Rachel A; Thompson, Hannis W; Refaai, Majed A; Quillen, Karen; Lopez, Ana Ortega; Goldfinger, Dennis; Muram, Talia; Thompson, Hannis

    2009-02-01

    The following abstracts are compiled from Check Sample exercises published in 2008. These peer-reviewed case studies assist laboratory professionals with continuing medical education and are developed in the areas of clinical chemistry, cytopathology, forensic pathology, hematology, microbiology, surgical pathology, and transfusion medicine. Abstracts for all exercises published in the program will appear annually in AJCP.

  12. Ground-state properties of a supersymmetric fermion chain

    International Nuclear Information System (INIS)

    Fendley, Paul; Hagendorf, Christian

    2011-01-01

    We analyze the ground state of a strongly interacting fermion chain with a supersymmetry. We conjecture a number of exact results, such as a hidden duality between weak and strong couplings. By exploiting a scale-free property of the perturbative expansions, we find exact expressions for the order parameters, yielding the critical exponents. We show that the ground state of this fermion chain and another model in the same universality class, the XYZ chain along a line of couplings, are both written in terms of the same polynomials. We demonstrate this explicitly for up to N = 24 sites and provide consistency checks for large N. These polynomials satisfy a recursion relation related to the Painlevé VI differential equation and, using a scale-free property of these polynomials, we derive a simple and exact formula for their N→∞ limit

  13. Implementing Model-Check for Employee and Management Satisfaction

    Science.gov (United States)

    Jones, Corey; LaPha, Steven

    2013-01-01

    This presentation will discuss methods to which ModelCheck can be implemented to not only improve model quality, but also satisfy both employees and management through different sets of quality checks. This approach allows a standard set of modeling practices to be upheld throughout a company, with minimal interaction required by the end user. The presenter will demonstrate how to create multiple ModelCheck standards, preventing users from evading the system, and how it can improve the quality of drawings and models.

  14. On the safeness of examinees and the reliability of system

    International Nuclear Information System (INIS)

    Kudo, Kazumi; Kanda, Kosuke; Saito, Kazuhiko; Maesawa, Tsuneharu; Idekami, Tomio

    1979-01-01

    The control technique of the reliability of examination system was investigated from the viewpoint of patient safety and image information, based on the prevention of microshock owing to circulatory organ checking system. As for the equipments in hospitals, the size of rooms, air conditioning system, power source installation, earth and piping arrangements should be fully discussed at the planning stage. EPR system must be introduced for the prevention for microshock. Intensive education and training are required for operators to secure safeness in operation. Thorough care should be taken to prevent bacilli infection. Further examinations were made on the control technique of the reliability of photographing system from viewpoint of image information, and it is necessary to study the factors for obtaining the reliability of compound machinery components and the devices of generating radiation. (Kobatake, H.)

  15. The criticality check and its applicability for nuclear material accounting

    International Nuclear Information System (INIS)

    Sanchez Espinoza, V.H.; Adam, E.; Knorr, J.

    1988-01-01

    Different procedures are used by the realization of nuclear material check by the IAEA. The criticality check belongs to these methods and it appropriates especially to verification of the nuclear material inventory of reactors. General aspects of the applicability of this check procedure are formulated and application criteria are deduced. By the example of solid-moderated homogeneous zero-power reactors it is demonstrated the unsecurity which is to be reckoned by applying the criticality check. Finally a possibility for the reduction of errors in core material determination by additional measuring methods without questioning the criticality check method is presented. (author)

  16. Calibration and check light source

    Energy Technology Data Exchange (ETDEWEB)

    Nejedla, B; Krotil, J

    1979-02-15

    The light source is designed for calibrating photomultipliers and checking the function of the thermoluminescent dosemeters evaluation equipment. The check light source consists of a polymer material-based (polyvinyl toluene) plastic scintillator and a 2-phenyl-5-(4-bisphenyl)-1,3,4-oxadiazol and/or paraterphenyl activator, and of emission spectrum shifters for response in the green and the blue light regions. The plastic scintillator is sealed in a case to whose bottom a radiation source is fixed, such as a /sup 90/Sr-/sup 90/Y source of an activity of 1.85x10/sup 3/s/sup -1/ to 0.74x10/sup 9/s/sup -1/.

  17. 26 CFR 301.6657-1 - Bad checks.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Bad checks. 301.6657-1 Section 301.6657-1... Additions to the Tax and Additional Amounts § 301.6657-1 Bad checks. (a) In general. Except as provided in... district director that it was tendered in good faith with reasonable cause to believe that it would be duly...

  18. Vertical pump with free floating check valve

    International Nuclear Information System (INIS)

    Lindsay, M.

    1980-01-01

    A vertical pump is described which has a bottom discharge with a free floating check valve disposed in the outlet plenum thereof. The free floating check valve comprises a spherical member with a hemispherical cage-like member attached thereto which is capable of allowing forward or reverse flow under appropriate conditions while preventing reverse flow under inappropriate conditions

  19. Model Checking Temporal Logic Formulas Using Sticker Automata

    Science.gov (United States)

    Feng, Changwei; Wu, Huanmei

    2017-01-01

    As an important complex problem, the temporal logic model checking problem is still far from being fully resolved under the circumstance of DNA computing, especially Computation Tree Logic (CTL), Interval Temporal Logic (ITL), and Projection Temporal Logic (PTL), because there is still a lack of approaches for DNA model checking. To address this challenge, a model checking method is proposed for checking the basic formulas in the above three temporal logic types with DNA molecules. First, one-type single-stranded DNA molecules are employed to encode the Finite State Automaton (FSA) model of the given basic formula so that a sticker automaton is obtained. On the other hand, other single-stranded DNA molecules are employed to encode the given system model so that the input strings of the sticker automaton are obtained. Next, a series of biochemical reactions are conducted between the above two types of single-stranded DNA molecules. It can then be decided whether the system satisfies the formula or not. As a result, we have developed a DNA-based approach for checking all the basic formulas of CTL, ITL, and PTL. The simulated results demonstrate the effectiveness of the new method. PMID:29119114

  20. Deployment of check-in nodes in complex networks

    Science.gov (United States)

    Jiang, Zhong-Yuan; Ma, Jian-Feng

    2017-01-01

    In many real complex networks such as the city road networks and highway networks, vehicles often have to pass through some specially functioned nodes to receive check-in like services such as gas supplement at gas stations. Based on existing network structures, to guarantee every shortest path including at least a check-in node, the location selection of all check-in nodes is very essential and important to make vehicles to easily visit these check-in nodes, and it is still remains an open problem in complex network studies. In this work, we aim to find possible solutions for this problem. We first convert it into a set cover problem which is NP-complete and propose to employ the greedy algorithm to achieve an approximate result. Inspired by heuristic information of network structure, we discuss other four check-in node location deployment methods including high betweenness first (HBF), high degree first (HDF), random and low degree first (LDF). Finally, we compose extensive simulations in classical scale-free networks, random networks and real network models, and the results can well confirm the effectiveness of the greedy algorithm. This work has potential applications into many real networks.

  1. The impact of gender on the assessment of body checking behavior.

    Science.gov (United States)

    Alfano, Lauren; Hildebrandt, Tom; Bannon, Katie; Walker, Catherine; Walton, Kate E

    2011-01-01

    Body checking includes any behavior aimed at global or specific evaluations of appearance characteristics. Men and women are believed to express these behaviors differently, possibly reflecting different socialization. However, there has been no empirical test of the impact of gender on body checking. A total of 1024 male and female college students completed two measures of body checking, the Body Checking Questionnaire and the Male Body Checking Questionnaire. Using multiple group confirmatory factor analysis, differential item functioning (DIF) was explored in a composite of these measures. Two global latent factors were identified (female and male body checking severity), and there were expected gender differences in these factors even after controlling for DIF. Ten items were found to be unbiased by gender and provide a suitable brief measure of body checking for mixed gender research. Practical applications for body checking assessment and theoretical implications are discussed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Compliance checking of data-aware and resource-aware compliance requirements

    NARCIS (Netherlands)

    Ramezani Taghiabadi, E.; Gromov, V.; Fahland, D.; Aalst, van der W.M.P.; Meersman, R.; Panetto, H.; Dillon, T.; Missikoff, M.; Liu, L.; Pastor, O.; Cuzzocrea, A.; Sllis, T.

    2014-01-01

    Compliance checking is gaining importance as today’s organizations need to show that their business practices are in accordance with predefined (legal) requirements. Current compliance checking techniques are mostly focused on checking the control-flow perspective of business processes. This paper

  3. UK Department of Environment Quality Checking Laboratory

    International Nuclear Information System (INIS)

    Burgoyne, K.E.; Green, T.H.; Maxwell, D.J.; Smith, D.L.G.

    1990-01-01

    The purpose of Taywood Engineering Ltd was to develop and evaluate techniques for the non-destructive and destructive examination of both low and intermediate level radioactive waste packages. The contract also included a study on the conceptual design and cost of a permanent Waste Quality Checking facility. The June 1986 contract was completed in November 1989. A second contract was awarded in September 1989 to extend the scope to include Quality Checking of hazardous waste and to increase the throughput of low level waste. This paper highlights the techniques developed during these programmes and applied to a range of real low level waste packages. The feasibility of operating a pilot scale facility for the independent Quality Checking of LLW has been successfully demonstrated. (orig.)

  4. Model checking exact cost for attack scenarios

    DEFF Research Database (Denmark)

    Aslanyan, Zaruhi; Nielson, Flemming

    2017-01-01

    Attack trees constitute a powerful tool for modelling security threats. Many security analyses of attack trees can be seamlessly expressed as model checking of Markov Decision Processes obtained from the attack trees, thus reaping the benefits of a coherent framework and a mature tool support....... However, current model checking does not encompass the exact cost analysis of an attack, which is standard for attack trees. Our first contribution is the logic erPCTL with cost-related operators. The extended logic allows to analyse the probability of an event satisfying given cost bounds and to compute...... the exact cost of an event. Our second contribution is the model checking algorithm for erPCTL. Finally, we apply our framework to the analysis of attack trees....

  5. The SafeCOP ECSEL Project: Safe Cooperating Cyber-Physical Systems Using Wireless Communication

    DEFF Research Database (Denmark)

    Pop, Paul; Scholle, Detlef; Hansson, Hans

    2016-01-01

    This paper presents an overview of the ECSEL project entitled "Safe Cooperating Cyber-Physical Systems using Wireless Communication" (SafeCOP), which runs during the period 2016 -- 2019. SafeCOP targets safety-related Cooperating Cyber-Physical Systems (CO-CPS) characterised by use of wireless...... detection of abnormal behaviour, triggering if needed a safe degraded mode. SafeCOP will also develop methods and tools, which will be used to produce safety assurance evidence needed to certify cooperative functions. SafeCOP will extend current wireless technologies to ensure safe and secure cooperation...

  6. Cycle time reduction by Html report in mask checking flow

    Science.gov (United States)

    Chen, Jian-Cheng; Lu, Min-Ying; Fang, Xiang; Shen, Ming-Feng; Ma, Shou-Yuan; Yang, Chuen-Huei; Tsai, Joe; Lee, Rachel; Deng, Erwin; Lin, Ling-Chieh; Liao, Hung-Yueh; Tsai, Jenny; Bowhill, Amanda; Vu, Hien; Russell, Gordon

    2017-07-01

    The Mask Data Correctness Check (MDCC) is a reticle-level, multi-layer DRC-like check evolved from mask rule check (MRC). The MDCC uses extended job deck (EJB) to achieve mask composition and to perform a detailed check for positioning and integrity of each component of the reticle. Different design patterns on the mask will be mapped to different layers. Therefore, users may be able to review the whole reticle and check the interactions between different designs before the final mask pattern file is available. However, many types of MDCC check results, such as errors from overlapping patterns usually have very large and complex-shaped highlighted areas covering the boundary of the design. Users have to load the result OASIS file and overlap it to the original database that was assembled in MDCC process on a layout viewer, then search for the details of the check results. We introduce a quick result-reviewing method based on an html format report generated by Calibre® RVE. In the report generation process, we analyze and extract the essential part of result OASIS file to a result database (RDB) file by standard verification rule format (SVRF) commands. Calibre® RVE automatically loads the assembled reticle pattern and generates screen shots of these check results. All the processes are automatically triggered just after the MDCC process finishes. Users just have to open the html report to get the information they need: for example, check summary, captured images of results and their coordinates.

  7. Context-aware compliance checking

    NARCIS (Netherlands)

    Werf, van der J.M.E.M.; Verbeek, H.M.W.; Aalst, van der W.M.P.; Barros, A.; Gal, A.; Kindler, E.

    2012-01-01

    Organizations face more and more the burden to show that their business is compliant with respect to many different boundaries. The activity of compliance checking is commonly referred to as auditing. As information systems supporting the organization’s business record their usage, process mining

  8. A voice-actuated wind tunnel model leak checking system

    Science.gov (United States)

    Larson, William E.

    1989-01-01

    A computer program has been developed that improves the efficiency of wind tunnel model leak checking. The program uses a voice recognition unit to relay a technician's commands to the computer. The computer, after receiving a command, can respond to the technician via a voice response unit. Information about the model pressure orifice being checked is displayed on a gas-plasma terminal. On command, the program records up to 30 seconds of pressure data. After the recording is complete, the raw data and a straight line fit of the data are plotted on the terminal. This allows the technician to make a decision on the integrity of the orifice being checked. All results of the leak check program are stored in a database file that can be listed on the line printer for record keeping purposes or displayed on the terminal to help the technician find unchecked orifices. This program allows one technician to check a model for leaks instead of the two or three previously required.

  9. Safe Kids Worldwide

    Science.gov (United States)

    ... Blog Videos Newsletter facebook twitter instagram pinterest gplus youtube Search Menu Why It Matters Who We Are What We Do Find Your Safe Kids Safe Kids Day Main menu Keeping All Kids Safe Safety Tips Get Involved 4 Star Charity Donate Text Burns and Scalds 4 tips ...

  10. Get Your Kids Moving and Check Some Chores off Your List

    Science.gov (United States)

    ... Check Recipe Certification Program Nutrition Requirements Heart-Check Professional Resources Contact the Heart-Check Certification Program Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering ...

  11. PSYCHE, ENDF/B Data Consistency Check in ENDF Format

    International Nuclear Information System (INIS)

    Dunford, Charles L.

    2007-01-01

    1 - Description of program or function: PSYCHE is a program for checking the physics content of an evaluated data file. It can recognise the difference between ENDF-5 or ENDF-6 formats and performs its tests accordingly. Version 7.01 (April 2005): set success flag after return from begin, added potential scattering test formerly in Fizcon. Version 7.02 (May 2005): Fixed bug in calculation of L=2 penetrability. 2 - Method of solution: PSYCHE checks for energy conservation for emitted neutrons and photons, checks Wick's limit for elastic scattering, analyses resonance parameter statistics, calculates thermal cross sections and resonance integrals, examines continuity across resonance region boundaries and checks 'Q' values against mass tables

  12. Consistency Checking of Web Service Contracts

    DEFF Research Database (Denmark)

    Cambronero, M. Emilia; Okika, Joseph C.; Ravn, Anders Peter

    2008-01-01

    Behavioural properties are analyzed for web service contracts formulated in Business Process Execution Language (BPEL) and Choreography Description Language (CDL). The key result reported is an automated technique to check consistency between protocol aspects of the contracts. The contracts...... are abstracted to (timed) automata and from there a simulation is set up, which is checked using automated tools for analyzing networks of finite state processes. Here we use the Concurrency Work Bench. The proposed techniques are illustrated with a case study that include otherwise difficult to analyze fault...

  13. Use of Microgravity to Assess the Effects of El Nino on Ground-Water Storage in Southern Arizona

    Science.gov (United States)

    Parker, John T.C.; Pool, Donald R.

    1998-01-01

    The availability of ground water is of extreme importance in areas, such as southern Arizona, where it is the main supply for agricultural, industrial, or domestic purposes. Where ground-water use exceeds recharge, monitoring is critical for managing water supplies. Typically, monitoring has been done by measuring water levels in wells; however, this technique only partially describes ground-water conditions in a basin. A new application of geophysical technology is enabling U.S. Geological Survey (USGS) scientists to measure changes in the amount of water in an aquifer using a network of microgravity stations. This technique enables a direct measurement of ground-water depletion and recharge. In Tucson, Arizona, residents have relied solely upon ground water for most of their needs since the 19th century. Water levels in some wells in the Tucson area have declined more than 200 ft in the past 50 years. Similar drops in water levels have occurred elsewhere in Arizona. In response to the overdrafting of ground water, the State of Arizona passed legislation designed to attain 'safe yield,' which is defined as a balance between ground-water withdrawals and annual recharge of aquifers. To monitor progress in complying with the legislation, ground-water withdrawals are measured and estimated, and annual recharge is estimated. The Tucson Basin and Avra Valley are two ground-water basins that form the Tucson Active Management Area (TAMA), which by State statute must attain 'safe yield' by the year 2025.

  14. Checking BEBC superconducting magnet

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The superconducting coils of the magnet for the 3.7 m Big European Bubble Chamber (BEBC) had to be checked, see Annual Report 1974, p. 60. The photo shows a dismantled pancake. By December 1974 the magnet reached again the field design value of 3.5 T.

  15. Quality checking of radioactive and hazardous waste

    International Nuclear Information System (INIS)

    Billington, D.M.; Burgoyne, S.M.J.; Dale, C.J.

    1992-01-01

    This report describes the work of the HMIP Waste Quality Checking Laboratory (WQCL) for the period September 1989 -August 1991. The WQCL has conducted research and development of procedures for the receipt, sampling and analysis of low level solid radioactive waste (LLW), intermediate level radioactive waste (ILW) and hazardous chemical waste (HW). Operational facilities have been commissioned for quality checking both LLW and HW. Waste quality checking has been completed on LLW packages seized from the UK waste disposal route by HMIP Inspectors. Packages have ranged in size from the 200 litre steel drum to half-height ISO freight container. Development work was continued on methods of sample extraction and radio-chemical analysis for cement encapsulated ILW in the form of magnox, graphite and stainless steel. This work was undertaken on non-radioactive simulants. (author)

  16. Model Checking Markov Reward Models with Impulse Rewards

    NARCIS (Netherlands)

    Cloth, Lucia; Katoen, Joost-Pieter; Khattri, Maneesh; Pulungan, Reza; Bondavalli, Andrea; Haverkort, Boudewijn; Tang, Dong

    This paper considers model checking of Markov reward models (MRMs), continuous-time Markov chains with state rewards as well as impulse rewards. The reward extension of the logic CSL (Continuous Stochastic Logic) is interpreted over such MRMs, and two numerical algorithms are provided to check the

  17. Checking Consistency of Pedigree Information is NP-complete

    DEFF Research Database (Denmark)

    Aceto, Luca; Hansen, Jens A.; Ingolfsdottir, Anna

    Consistency checking is a fundamental computational problem in genetics. Given a pedigree and information on the genotypes of some of the individuals in it, the aim of consistency checking is to determine whether these data are consistent with the classic Mendelian laws of inheritance. This probl...

  18. Strategic Planning through Model Checking of ATL Formulae

    NARCIS (Netherlands)

    Jamroga, W.J.; Rutkowski, L.; Siekmann, J.; Tadeusiewicz, R.; Zadeh, L.A.

    2004-01-01

    Model checking of temporal logic has already been proposed for automatic planning. In this paper, we introduce a simple adaptation of the ATL model checking algorithm that returns a strategy to achieve given goal. We point out that the algorithm generalizes minimaxing, and that ATL models generalize

  19. First experiences with the LHC BLM sanity checks

    CERN Document Server

    Emery, J; Effinger, E; Nordt, A; Sapinski, M G; Zamantzas, C

    2010-01-01

    The reliability concerns have driven the design of the Large Hardron Collider (LHC) Beam Loss Monitoring (BLM) system from the early stage of the studies up to the present commissioning and the latest development of diagnostic tools. To protect the system against non-conformities, new ways of automatic checking have been developed and implemented. These checks are regularly and systematically executed by the LHC operation team to ensure that the system status is after each test "as good as new". The sanity checks are part of this strategy. They are testing the electrical part of the detectors (ionisation chamber or secondary emission detector), their cable connections to the front-end electronics, further connections to the back-end electronics and their ability to request a beam abort. During the installation and in the early commissioning phase, these checks have shown their ability to find also non-conformities caused by unexpected failure event scenarios. In every day operation, a non-conformity discovere...

  20. Review and analysis of check valve failure data

    International Nuclear Information System (INIS)

    Todd, M.D.; Casada, D.A.

    1992-01-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost and decreased system availability. There has been, in response, additional attention given to check valves by utilities, as well as the US Nuclear Regulatory Commission and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. Oak Ridge National Laboratory is currently conducting a detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are being considered during the review, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions

  1. Safety and Availability Checking for User Authorization Queries in RBAC

    Directory of Open Access Journals (Sweden)

    Jian-feng Lu

    2012-09-01

    Full Text Available This paper introduces the notion of safety and availability checking for user authorization query processing, and develop a recursive algorithm use the ideas from backtracking-based search techniques to search for the optimal solution. For the availability checking, we introduce the notion of max activatable set (MAS, and show formally how MAS can be determined in a hybrid role hierarchy. For the safety checking, we give a formal definition of dynamic separation-of-duty (DSoD policies, and show how to reduce the safety checking for DSoD to a SAT instance.

  2. The Activity Check of Brachytherapy Isotope

    International Nuclear Information System (INIS)

    Kim, Gun Oh; Lee, Byung Koo; Kwon, Young Ho

    2004-01-01

    An isotope Ir-192, which is used in brachytherapy depends on import in whole quantities. There are a few ways for its activity. measurement using Welltype chamber or the way to rely on authentic decay table of manufacturer. In-air dosimetry using Farmer Chamber, etc. In this paper, let me introduce the way using Farmer chamber which is easier and simple. With the Farmer chamber and source calibration jig, take a measurement the activity of an isotope Ir-192 and compare the value with the value from decay table of manufacturer and check the activity of source. The result of measurement, compared the value from decay table, by ±2.1. (which belongs to recommendable value for AAPM ±5% as difference of error range). It is possible to use on clinical medicine. With the increase in use of brachytherapy, the increase of import is essential. And an accurate activity check of source is compulsory. For the activity check of source, it was possible to use Farmer chamber and source calibration jig without additional purchase of Well type chamber.

  3. 31 CFR 211.1 - Withholding delivery of checks.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false Withholding delivery of checks. 211.1 Section 211.1 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) FISCAL SERVICE, DEPARTMENT OF THE TREASURY FINANCIAL MANAGEMENT SERVICE DELIVERY OF CHECKS AND WARRANTS TO...

  4. Multi-Valued Modal Fixed Point Logics for Model Checking

    Science.gov (United States)

    Nishizawa, Koki

    In this paper, I will show how multi-valued logics are used for model checking. Model checking is an automatic technique to analyze correctness of hardware and software systems. A model checker is based on a temporal logic or a modal fixed point logic. That is to say, a system to be checked is formalized as a Kripke model, a property to be satisfied by the system is formalized as a temporal formula or a modal formula, and the model checker checks that the Kripke model satisfies the formula. Although most existing model checkers are based on 2-valued logics, recently new attempts have been made to extend the underlying logics of model checkers to multi-valued logics. I will summarize these new results.

  5. Estimated emission reductions from California's enhanced Smog Check program.

    Science.gov (United States)

    Singer, Brett C; Wenzel, Thomas P

    2003-06-01

    The U.S. Environmental Protection Agency requires that states evaluate the effectiveness of their vehicle emissions inspection and maintenance (I/M) programs. This study demonstrates an evaluation approach that estimates mass emission reductions over time and includes the effect of I/M on vehicle deterioration. It includes a quantitative assessment of benefits from pre-inspection maintenance and repairs and accounts for the selection bias effect that occurs when intermittent high emitters are tested. We report estimates of one-cycle emission benefits of California's Enhanced Smog Check program, ca. 1999. Program benefits equivalent to metric tons per day of prevented emissions were calculated with a "bottom-up" approach that combined average per vehicle reductions in mass emission rates (g/gal) with average per vehicle activity, resolved by model year. Accelerated simulation mode test data from the statewide vehicle information database (VID) and from roadside Smog Check testing were used to determine 2-yr emission profiles of vehicles passing through Smog Check and infer emission profiles that would occur without Smog Check. The number of vehicles participating in Smog Check was also determined from the VID. We estimate that in 1999 Smog Check reduced tailpipe emissions of HC, CO, and NO(x) by 97, 1690, and 81 t/d, respectively. These correspond to 26, 34, and 14% of the HC, CO, and NO(x) that would have been emitted by vehicles in the absence of Smog Check. These estimates are highly sensitive to assumptions about vehicle deterioration in the absence of Smog Check. Considering the estimated uncertainty in these assumptions yields a range for calculated benefits: 46-128 t/d of HC, 860-2200 t/d of CO, and 60-91 t/d of NO(x). Repair of vehicles that failed an initial, official Smog Check appears to be the most important mechanism of emission reductions, but pre-inspection maintenance and repair also contributed substantially. Benefits from removal of nonpassing

  6. A system to test the ground surface conditions of construction sites--for safe and efficient work without physical strain.

    Science.gov (United States)

    Koningsveld, Ernst; van der Grinten, Maarten; van der Molen, Henk; Krause, Frank

    2005-07-01

    Ground surface conditions on construction sites have an important influence on the health and safety of workers and their productivity. The development of an expert-based "working conditions evaluation" system is described, intended to assist site managers in recognising unsatisfactory ground conditions and remedying these. The system was evaluated in the period 2002-2003. The evaluation shows that companies recognize poor soil/ground conditions as problematic, but are not aware of the specific physical workload hazards. The developed methods allow assessment of the ground surface quality and selection of appropriate measures for improvement. However, barriers exist at present to wide implementation of the system across the industry. Most significant of these is that responsibility for a site's condition is not clearly located within contracting arrangements, nor is it a topic of serious negotiation.

  7. Delivery quality assurance with ArcCHECK

    International Nuclear Information System (INIS)

    Neilson, Christopher; Klein, Michael; Barnett, Rob; Yartsev, Slav

    2013-01-01

    Radiation therapy requires delivery quality assurance (DQA) to ensure that treatment is accurate and closely follows the plan. We report our experience with the ArcCHECK phantom and investigate its potential optimization for the DQA process. One-hundred seventy DQA plans from 84 patients were studied. Plans were classified into 2 groups: those with the target situated on the diodes of the ArcCHECK (D plans) and those with the target situated at the center (C plans). Gamma pass rates for 8 target sites were examined. The parameters used to analyze the data included 3%/3 mm with the Van Dyk percent difference criteria (VD) on, 3%/3 mm with the VD off, 2%/2 mm with the VD on, and x/3 mm with the VD on and the percentage dosimetric agreement “x” for diode plans adjusted. D plans typically displayed maximum planned dose (MPD) on the cylindrical surface containing ArcCHECK diodes than center plans, resulting in inflated gamma pass rates. When this was taken into account by adjusting the percentage dosimetric agreement, C plans outperformed D plans by an average of 3.5%. ArcCHECK can streamline the DQA process, consuming less time and resources than radiographic films. It is unnecessary to generate 2 DQA plans for each patient; a single center plan will suffice. Six of 8 target sites consistently displayed pass rates well within our acceptance criteria; the lesser performance of head and neck and spinal sites can be attributed to marginally lower doses and increased high gradient of plans

  8. Assessment of diagnostic methods for determining degradation of check valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of check valves in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL check valve aging assessment with emphasis on the identification, evaluation, and application of check valve monitoring methods and techniques. Several check valve monitoring methods are described and compared. These methods include: acoustic emission monitoring, ultrasonic inspection, magnetic flux signature analysis (MFSA), external magnetics. These diagnostic technologies were shown to be useful in determining check valve condition (e.g., disc position, disc motion, and seat leakage), although none of the methods was by itself, successful in monitoring all three condition indicators. The combination of acoustic emission with either ultrasonics or one of the magnetic technologies, however, yields a monitoring system that succeeds in providing the sensitivity to detect all major check valve operating conditions. Other areas covered in the paper include descriptions of relevant regulatory issues, utility group activities, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  9. Radioactive check sources for alpha and beta sensitive radiological instrumentation

    International Nuclear Information System (INIS)

    Barnett, J.M.; Kane, J.E. II.

    1994-06-01

    Since 1991, the Westinghouse Hanford Company has examined the construction and use of alpha and beta radioactive check sources for calibrating instruments and for performing response checks of instruments used for operational and environmental radiation detection. The purpose of using a radioactive check source is to characterize the response of a radiation monitoring instrument in the presence of radioactivity. To accurately calibrate the instrument and check its response, the check source used must emulate as closely as possible the actual physical and isotopic conditions being monitored. The isotope employed and the physical methods used to fabricate the check source (among other factors) determine instrument response. Although information from applicable national and international standards, journal articles, books, and government documents was considered, empirical data collected is most valuable when considering the type of source to use for a particular application. This paper presents source construction methods, use considerations, and standard recommendations. The results of a Hanford Site evaluation of several types of alpha and beta sources are also given

  10. "Same Room, Safe Place".

    Science.gov (United States)

    Keene Woods, Nikki

    2017-04-01

    There are many different professional stances on safe sleep and then there is the reality of caring for a newborn. There is a debate among professionals regarding safe sleep recommendations. The continum of recommendations vary from the American Academy of Pediatrics (AAP) Safe Sleep Guidelines to the bed-sharing recommendations from the Mother-Baby Behavioral Sleep Laboratory. The lack of consistent and uniform safe sleep recommendations from health professionals has been confusing for families but has more recently raised a real professional ethical dilemma. Despite years of focused safe sleep community education and interventions, sleep-related infant deaths are on the rise in many communities. This commentary calls for a united safe sleep message from all health professionals to improve health for mothers and infants most at-risk, "Same Room, Safe Place."

  11. Double checking medicines: defence against error or contributory factor?

    Science.gov (United States)

    Armitage, Gerry

    2008-08-01

    The double checking of medicines in health care is a contestable procedure. It occupies an obvious position in health care practice and is understood to be an effective defence against medication error but the process is variable and the outcomes have not been exposed to testing. This paper presents an appraisal of the process using data from part of a larger study on the contributory factors in medication errors and their reporting. Previous research studies are reviewed; data are analysed from a review of 991 drug error reports and a subsequent series of 40 in-depth interviews with health professionals in an acute hospital in northern England. The incident reports showed that errors occurred despite double checking but that action taken did not appear to investigate the checking process. Most interview participants (34) talked extensively about double checking but believed the process to be inconsistent. Four key categories were apparent: deference to authority, reduction of responsibility, automatic processing and lack of time. Solutions to the problems were also offered, which are discussed with several recommendations. Double checking medicines should be a selective and systematic procedure informed by key principles and encompassing certain behaviours. Psychological research may be instructive in reducing checking errors but the aviation industry may also have a part to play in increasing error wisdom and reducing risk.

  12. Experience from replacement and check of thermocouples during reconstruction of in-reactor temperature measurements at Bohunice V-1 units 1 and 2

    International Nuclear Information System (INIS)

    Slanina, M.; Stanc, J.

    2001-01-01

    Replacement of thermocouples in the protection tube blocks was a key phase of the reconstruction of in-reactor temperature measurements at Bohunice V-1 with regard to the success, reliability and impact on safety of unit operation. The replacement consisted of reliable and safe withdrawal of 216 old thermocouples, their disposal and installation of new thermocouples into dry channels. In the material presented, this phase of reconstruction is described in details, with focus on the evaluation of replacement quality and check activities carried out at the new installed thermocouples. (Authors)

  13. Related Fact Checks: a tool for combating fake news

    OpenAIRE

    Guha, Sreya

    2017-01-01

    The emergence of "Fake News" and misinformation via online news and social media has spurred an interest in computational tools to combat this phenomenon. In this paper we present a new "Related Fact Checks" service, which can help a reader critically evaluate an article and make a judgment on its veracity by bringing up fact checks that are relevant to the article. We describe the core technical problems that need to be solved in building a "Related Fact Checks" service, and present results ...

  14. Check-up Measurement (update). Deliverable D5.22

    NARCIS (Netherlands)

    Holtzer, A.C.G.; Giessen, A.M.D. van der; Djurica, M.

    2015-01-01

    This deliverable D5.22 presents the GEN6 check-up measurement. It describes the most prominent outcomes of the GEN6 project up to this point in time. The check-up measurement helps to focus the monitoring towards the most relevant achievements of the project, such that an efficient and well-targeted

  15. Practical Approach on Lightning and Grounding Protection System

    OpenAIRE

    Shan Jose Varghese

    2015-01-01

    Lightning Protection and Grounding of Electrical and Mechanical equipment’s for the Protection of the Human Beings, Structure of the building and equipment protection, safe working of the Worker at Industry as per my latest practical knowledge in the site environment in extreme climatic condition of low lying areas of the Gulf Region in the challenging projects. All the conductor calculation, Lightning Risk Factor calculations, all the system information regarding the ...

  16. Ground assessment methods for nuclear power plant

    International Nuclear Information System (INIS)

    1985-01-01

    It is needless to say that nuclear power plant must be constructed on the most stable and safe ground. Reliable assessment method is required for the purpose. The Ground Integrity Sub-committee of the Committee of Civil Engineering of Nuclear Power Plant started five working groups, the purpose of which is to systematize the assessment procedures including geological survey, ground examination and construction design. The works of working groups are to establishing assessment method of activities of faults, standardizing the rock classification method, standardizing assessment and indication method of ground properties, standardizing test methods and establishing the application standard for design and construction. Flow diagrams for the procedures of geological survey, for the investigation on fault activities and ground properties of area where nuclear reactor and important outdoor equipments are scheduled to construct, were established. And further, flow diagrams for applying investigated results to design and construction of plant, and for determining procedure of liquidification nature of ground etc. were also established. These systematized and standardized methods of investigation are expected to yield reliable data for assessment of construction site of nuclear power plant and lead to the safety of construction and operation in the future. In addition, the execution of these systematized and detailed preliminary investigation for determining the construction site of nuclear power plant will make much contribution for obtaining nation-wide understanding and faith for the project. (Ishimitsu, A.)

  17. Treasury Check Verification Query (TCVQ)

    Data.gov (United States)

    Social Security Administration — The TCVQ system determines the SSN of an individual whose check has been returned to a local field office. The FO is able to request this information via the TCVQ...

  18. Progress Check Module; Basic Electricity and Electronics Individualized Learning System. Progress Check Booklet.

    Science.gov (United States)

    Bureau of Naval Personnel, Washington, DC.

    The Progress Check Booklet is designed to be used by the student working in the programed course to determine if he has mastered the concepts in the course booklets on: electrical current; voltage; resistance; measuring current and voltage in series circuits; relationships of current, voltage, and resistance; parellel circuits; combination…

  19. From safe yield to sustainable development of water resources - The Kansas experience

    Science.gov (United States)

    Sophocleous, M.

    2000-01-01

    This paper presents a synthesis of water sustainability issues from the hydrologic perspective. It shows that safe yield is a flawed concept and that sustainability is an idea that is broadly used but perhaps not well understood. In general, the sustainable yield of an aquifer must be considerably less than recharge if adequate amounts of water are to be available to sustain both the quantity and quality of streams, springs, wetlands, and ground-water-dependent ecosystems. To ensure sustainability, it is imperative that water limits be established based on hydrologic principles of mass balance. To establish water-use policies and planning horizons, the transition curves of aquifer systems from ground-water storage depletion to induced recharge of surface water need to be developed. Present-day numerical models are capable of generating such transition curves. Several idealized examples of aquifer systems show how this could be done. Because of the complexity of natural systems and the uncertainties in characterizing them, the current philosophy underlying sustainable management of water resources is based on the interconnected systems approach and on adaptive management. Examples of water-resources management from Kansas illustrate some of these concepts in a real-world setting. Some of the hallmarks of Kansas water management are the formation of local ground-water management districts, the adoption of minimum streamflow standards, the use of modified safe-yield policies in some districts, the implementation of integrated resource planning by the City of Wichita, and the subbasin water-resources management program in potential problem areas. These are all appropriate steps toward sustainable development. The Kansas examples show that local decision-making is the best way to fully account for local variability in water management. However, it is imperative that public education and involvement be encouraged, so that system complexities and constraints are better

  20. 31 CFR 10.31 - Negotiation of taxpayer checks.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Negotiation of taxpayer checks. 10.31 Section 10.31 Money and Finance: Treasury Office of the Secretary of the Treasury PRACTICE BEFORE THE INTERNAL REVENUE SERVICE Duties and Restrictions Relating to Practice Before the Internal Revenue Service § 10.31 Negotiation of taxpayer checks. ...

  1. "Working towards being ready": A grounded theory study of how practising midwives maintain their ongoing competence to practise their profession.

    Science.gov (United States)

    Calvert, Susan; Smythe, Elizabeth; McKenzie-Green, Barbara

    2017-07-01

    to present a grounded theory research study explaining how New Zealand midwives maintain their ongoing competence to practise their profession. grounded theory, an interpretive emergent research methodology was used to examine the process of maintaining competence in midwifery practice. New Zealand urban and rural practice settings. twenty-six midwives from across New Zealand were interviewed and asked about maintaining their competence to practise. Five midwives were interviewed twice, to explore the emerging findings and as one method of member checking. the grounded theory of 'working towards being ready' describes a continuous process in which midwives engage as they work to maintain practice competence. The component parts comprise professional positioning, identifying needs, strategizing solutions and reflecting on practice. The process is contextual, diverse and is influenced by the practice setting where the salient conditions of resourcing, availability and opportunity for engagement in activities are significant. across the midwifery profession, midwives in New Zealand are currently working under the generic umbrella of midwifery practice. Midwives work across a range of practice arenas in diverse ways focussed on providing safe care and require a range of professional development activities germane to their area of practice. When the midwife has access to professional development pertinent to their practice, women and the profession benefit. As there is diversity of practice, then mandated processes for ongoing competence need to have flexibility to reflect that diversity. midwives engage in development that allows them to remain current in practice and that enables them to provide appropriate care to women and their babies. As a consequence they can develop expertise in certain aspects of midwifery. Mandated processes that require engagement in activities aimed at demonstration of competence should be evaluated and tailored to ensure they meet the needs

  2. 42 CFR 433.40 - Treatment of uncashed or cancelled (voided) Medicaid checks.

    Science.gov (United States)

    2010-10-01

    ...) Medicaid checks. 433.40 Section 433.40 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT...) Medicaid checks. (a) Purpose. This section provides the rules to ensure that States refund the Federal...— Cancelled (voided) check means a Medicaid check issued by a State or fiscal agent which prior to its being...

  3. Shallow ground disposal of radioactive wastes. A guidebook

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    This guidebook outlines the factors to be considered in site selection, design, operation, shut-down and surveillance as well as the regulatory requirements of repositories for safe disposal of radioactive waste in shallow ground. No attempt is made to summarize the existing voluminous literature on the many facets of radioactive waste disposal. In the context of this guidebook, shallow ground disposal refers to the emplacement of radioactive waste, with or without engineered barriers, above or below the ground surface, where the final protective covering is of the order of a few metres thick. Deep geological disposal and other underground disposal methods, management of mill tailings and disposal into the sea have been or will be considered in other IAEA publications. These guidelines have been made sufficiently general to cover a broad variety of climatic, hydrogeological and biological conditions. They may need to be interpreted or modified to reflect local conditions and national regulations.

  4. Application of risk-based methods to inservice testing of check valves

    Energy Technology Data Exchange (ETDEWEB)

    Closky, N.B.; Balkey, K.R.; McAllister, W.J. [and others

    1996-12-01

    Research efforts have been underway in the American Society of Mechanical Engineers (ASME) and industry to define appropriate methods for the application of risk-based technology in the development of inservice testing (IST) programs for pumps and valves in nuclear steam supply systems. This paper discusses a pilot application of these methods to the inservice testing of check valves in the emergency core cooling system of Georgia Power`s Vogtle nuclear power station. The results of the probabilistic safety assessment (PSA) are used to divide the check valves into risk-significant and less-risk-significant groups. This information is reviewed by a plant expert panel along with the consideration of appropriate deterministic insights to finally categorize the check valves into more safety-significant and less safety-significant component groups. All of the more safety-significant check valves are further evaluated in detail using a failure modes and causes analysis (FMCA) to assist in defining effective IST strategies. A template has been designed to evaluate how effective current and emerging tests for check valves are in detecting failures or in finding significant conditions that are precursors to failure for the likely failure causes. This information is then used to design and evaluate appropriate IST strategies that consider both the test method and frequency. A few of the less safety-significant check valves are also evaluated using this process since differences exist in check valve design, function, and operating conditions. Appropriate test strategies are selected for each check valve that has been evaluated based on safety and cost considerations. Test strategies are inferred from this information for the other check valves based on similar check valve conditions. Sensitivity studies are performed using the PSA model to arrive at an overall IST program that maintains or enhances safety at the lowest achievable cost.

  5. DroidSafe

    Science.gov (United States)

    2016-12-01

    Massachusetts Avenue, Build E19-750 Cambridge , MA 02139-4307 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS...Activity objects illustrating the challenges of points-to and information flow analysis...measure how many malicious flows Droid- Safe was able to detect). As these results illustrate , DroidSafe implements an analysis of unprece- dented

  6. Code Optimization, Frozen Glassy Phase and Improved Decoding Algorithms for Low-Density Parity-Check Codes

    International Nuclear Information System (INIS)

    Huang Hai-Ping

    2015-01-01

    The statistical physics properties of low-density parity-check codes for the binary symmetric channel are investigated as a spin glass problem with multi-spin interactions and quenched random fields by the cavity method. By evaluating the entropy function at the Nishimori temperature, we find that irregular constructions with heterogeneous degree distribution of check (bit) nodes have higher decoding thresholds compared to regular counterparts with homogeneous degree distribution. We also show that the instability of the mean-field calculation takes place only after the entropy crisis, suggesting the presence of a frozen glassy phase at low temperatures. When no prior knowledge of channel noise is assumed (searching for the ground state), we find that a reinforced strategy on normal belief propagation will boost the decoding threshold to a higher value than the normal belief propagation. This value is close to the dynamical transition where all local search heuristics fail to identify the true message (codeword or the ferromagnetic state). After the dynamical transition, the number of metastable states with larger energy density (than the ferromagnetic state) becomes exponentially numerous. When the noise level of the transmission channel approaches the static transition point, there starts to exist exponentially numerous codewords sharing the identical ferromagnetic energy. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  7. Pre-Alignment Checks. Automotive Mechanics. Steering & Suspension. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Spignesi, B.

    This instructional package, one in a series of individualized instructional units on automotive steering and suspension, consists of a student guide and an instructor guide dealing with prealignment checks. Covered in the module are the following steps in a prealignment check: checking the ride height of a vehicle, checking the ball joints and the…

  8. Is drive for muscularity related to body checking behaviors in men athletes?

    Directory of Open Access Journals (Sweden)

    Leonardo de Sousa Fortes

    Full Text Available Abstract The aim of this study was to analyze the relationship between drive for muscularity and body checking behaviors in men athletes. Two hundred and twelve Brazilian athletes over 15 years of age participated. We used the Drive for Muscularity Scale (DMS to evaluate the drive for muscularity. The Male Body Checking Questionnaire was used to assess body checking behaviors. The findings demonstrated a relationship between the "body image-oriented muscularity" subscale of the DMS and body checking behaviors (p = 0.001. The results indicated differences in body checking among athletes with high and low levels of drive for muscularity. We concluded that drive for muscularity was related to body checking behaviors in men athletes.

  9. Safe havens in Europe

    DEFF Research Database (Denmark)

    Paldam, Martin

    2013-01-01

    Eleven safe havens exist in Europe providing offshore banking and low taxes. Ten of these states are very small while Switzerland is moderately small. All 11 countries are richer than their large neighbors. It is shown that causality is from small to safe haven to wealth, and that theoretically...... equilibriums are likely to exist where a certain regulation is substantially lower in a small country than in its big neighbor. This generates a large capital inflow to the safe havens. The pool of funds that may reach the safe havens is shown to be huge. It is far in excess of the absorptive capacity...... of the safe havens, but it still explains, why they are rich. Microstates offer a veil of anonymity to funds passing through, and Switzerland offers safe storage of funds....

  10. On the safe use of verify-and-record systems in external beam radiation therapy

    International Nuclear Information System (INIS)

    Seelantag, W.W.; Davis, J.B.

    1997-01-01

    Verify-and-record (V and R) systems are being used increasingly, not only for verification, but also for computer aided setup and chart printing. The close intercorrelation between V and R system and treatment routine requires new ideas for quality assurance (QA): pure ''machine checking'' as with treatment units is not sufficient anymore. The level of QA obviously depends on the tasks of the V and R system: the most advanced case of the system being used for computer aided setup and for chart printing is discussed -both are indispensable for an efficient use of V and R systems. Seven propositions are defined to make this not only efficient but safe. (author)

  11. Assessing Personality and Mood With Adjective Check List Methodology: A Review

    Science.gov (United States)

    Craig, Robert J.

    2005-01-01

    This article addresses the benefits and problems in using adjective check list methodology to assess personality. Recent developments in this assessment method are reviewed, emphasizing seminal adjective-based personality tests (Gough's Adjective Check List), mood tests (Lubin's Depressive Adjective Test, Multiple Affect Adjective Check List),…

  12. Spot-checks to measure general hygiene practice.

    Science.gov (United States)

    Sonego, Ina L; Mosler, Hans-Joachim

    2016-01-01

    A variety of hygiene behaviors are fundamental to the prevention of diarrhea. We used spot-checks in a survey of 761 households in Burundi to examine whether something we could call general hygiene practice is responsible for more specific hygiene behaviors, ranging from handwashing to sweeping the floor. Using structural equation modeling, we showed that clusters of hygiene behavior, such as primary caregivers' cleanliness and household cleanliness, explained the spot-check findings well. Within our model, general hygiene practice as overall concept explained the more specific clusters of hygiene behavior well. Furthermore, the higher general hygiene practice, the more likely children were to be categorized healthy (r = 0.46). General hygiene practice was correlated with commitment to hygiene (r = 0.52), indicating a strong association to psychosocial determinants. The results show that different hygiene behaviors co-occur regularly. Using spot-checks, the general hygiene practice of a household can be rated quickly and easily.

  13. Model Checking Algorithms for CTMDPs

    DEFF Research Database (Denmark)

    Buchholz, Peter; Hahn, Ernst Moritz; Hermanns, Holger

    2011-01-01

    Continuous Stochastic Logic (CSL) can be interpreted over continuoustime Markov decision processes (CTMDPs) to specify quantitative properties of stochastic systems that allow some external control. Model checking CSL formulae over CTMDPs requires then the computation of optimal control strategie...

  14. Traveling Safely with Medicines

    Science.gov (United States)

    ... Medications Safely My Medicine List How to Administer Traveling Safely with Medicines Planes, trains, cars – even boats ... your trip, ask your pharmacist about how to travel safely with your medicines. Make sure that you ...

  15. Efficient probabilistic model checking on general purpose graphic processors

    NARCIS (Netherlands)

    Bosnacki, D.; Edelkamp, S.; Sulewski, D.; Pasareanu, C.S.

    2009-01-01

    We present algorithms for parallel probabilistic model checking on general purpose graphic processing units (GPGPUs). For this purpose we exploit the fact that some of the basic algorithms for probabilistic model checking rely on matrix vector multiplication. Since this kind of linear algebraic

  16. CrossCheck plagiarism screening : Experience of the Journal of Epidemiology

    Science.gov (United States)

    Hashimoto, Katsumi

    Due to technological advances in the past two decades, researchers now have unprecedented access to a tremendous amount of useful information. However, because of the extreme pressure to publish, this abundance of information can sometimes tempt researchers to commit scientific misconduct. A serious form of such misconduct is plagiarism. Editors are always concerned about the possibility of publishing plagiarized manuscripts. The plagiarism detection tool CrossCheck allows editors to scan and analyze manuscripts effectively. The Journal of Epidemiology took part in a trial of CrossCheck, and this article discusses the concerns journal editors might have regarding the use of CrossCheck and its analysis. In addition, potential problems identified by CrossCheck, including self-plagiarism, are introduced.

  17. CAPD Software Development for Automatic Piping System Design: Checking Piping Pocket, Checking Valve Level and Flexibility

    International Nuclear Information System (INIS)

    Ari Satmoko; Edi Karyanta; Dedy Haryanto; Abdul Hafid; Sudarno; Kussigit Santosa; Pinitoyo, A.; Demon Handoyo

    2003-01-01

    One of several steps in industrial plant construction is preparing piping layout drawing. In this drawing, pipe and all other pieces such as instrumentation, equipment, structure should be modeled A software called CAPD was developed to replace and to behave as piping drafter or designer. CAPD was successfully developed by adding both subprogram CHKUPIPE and CHKMANV. The first subprogram can check and gives warning if there is piping pocket in the piping system. The second can identify valve position and then check whether valve can be handled by operator hand The main program CAPD was also successfully modified in order to be capable in limiting the maximum length of straight pipe. By limiting the length, piping flexibility can be increased. (author)

  18. A Method for Model Checking Feature Interactions

    DEFF Research Database (Denmark)

    Pedersen, Thomas; Le Guilly, Thibaut; Ravn, Anders Peter

    2015-01-01

    This paper presents a method to check for feature interactions in a system assembled from independently developed concurrent processes as found in many reactive systems. The method combines and refines existing definitions and adds a set of activities. The activities describe how to populate the ...... the definitions with models to ensure that all interactions are captured. The method is illustrated on a home automation example with model checking as analysis tool. In particular, the modelling formalism is timed automata and the analysis uses UPPAAL to find interactions....

  19. Experimental investigation of the check valve behaviour when the flow is reversing

    Directory of Open Access Journals (Sweden)

    Himr D.

    2017-01-01

    Full Text Available Check valve in a pipeline is supposed to prevent the reverse flow and to allow the flow in the positive direction. The construction of check valves follows these requirements, but the check valve must not cause pressure pulsations in transients. It means when the fluid is accelerating or decelerating. The article describes an experimental investigation of a swing check valve when the flow is changing its direction. The check valve was placed in an experimental circuit, where the pressure on the upstream and downstream side of the valve was measured and the current value of flow rate was determined. The goal was to simulate conditions in the real system, where the check valve slam had been observed.

  20. Masking potency and whiteness of noise at various noise check sizes.

    Science.gov (United States)

    Kukkonen, H; Rovamo, J; Näsänen, R

    1995-02-01

    The masking effect of spatial noise can be increased by increasing either the rms contrast or check size of noise. In this study, the authors investigated the largest noise check size that still mimics the effect of white noise in grating detection and how it depends on the bandwidth and spatial frequency of a grating. The authors measured contrast energy thresholds, E, for vertical cosine gratings at various spatial frequencies and bandwidths. Gratings were embedded in two-dimensional spatial noise. The side length of the square noise checks was varied in the experiments. The spectral density, N(0,0), of white spatial noise at zero frequency was calculated by multiplying the noise check area by the rms contrast of noise squared. The physical signal-to-noise ratio at threshold [E/N(0,0)]0.5 was initially constant but then started to decrease. The largest noise check that still produced a constant physical signal-to-noise ratio at threshold was directly proportional to the spatial frequency. When expressed as a fraction of grating cycle, the largest noise check size depended only on stimulus bandwidth. The smallest number of noise checks per grating cycle needed to mimic the effect of white noise decreased from 4.2 to 2.6 when the number of grating cycles increased from 1 to 64. Spatial noise can be regarded as white in grating detection if there are at least four square noise checks per grating cycle at all spatial frequencies.

  1. Intelligent Data Visualization for Cross-Checking Spacecraft System Diagnosis

    Science.gov (United States)

    Ong, James C.; Remolina, Emilio; Breeden, David; Stroozas, Brett A.; Mohammed, John L.

    2012-01-01

    Any reasoning system is fallible, so crew members and flight controllers must be able to cross-check automated diagnoses of spacecraft or habitat problems by considering alternate diagnoses and analyzing related evidence. Cross-checking improves diagnostic accuracy because people can apply information processing heuristics, pattern recognition techniques, and reasoning methods that the automated diagnostic system may not possess. Over time, cross-checking also enables crew members to become comfortable with how the diagnostic reasoning system performs, so the system can earn the crew s trust. We developed intelligent data visualization software that helps users cross-check automated diagnoses of system faults more effectively. The user interface displays scrollable arrays of timelines and time-series graphs, which are tightly integrated with an interactive, color-coded system schematic to show important spatial-temporal data patterns. Signal processing and rule-based diagnostic reasoning automatically identify alternate hypotheses and data patterns that support or rebut the original and alternate diagnoses. A color-coded matrix display summarizes the supporting or rebutting evidence for each diagnosis, and a drill-down capability enables crew members to quickly view graphs and timelines of the underlying data. This system demonstrates that modest amounts of diagnostic reasoning, combined with interactive, information-dense data visualizations, can accelerate system diagnosis and cross-checking.

  2. Study of check image using computed radiography

    International Nuclear Information System (INIS)

    Sato, Hiroshi

    2002-01-01

    There are two image forming methods both a check image and a portal image in the linacogram. It has been established the image forming method in the check image using computed radiography (CR). On the other hand, it is not established the image forming method in the portal image using CR yet. Usually, in the electric portal imaging device (EPID) is mainly used just before radiotherapy start. The usefulness of the portal image forming method by CR using in place of EPID is possible to confirm the precision for determining to specific position at the irradiate part and to the irradiate method for the human organs. There are some technical problems that, since in the early time, the linac graphy (LG) image have low resolution power. In order to improve to the resolution power in LG image, CR image technologies have been introduced to the check image forming method. Heavy metallic sheet (HMS) is used to the front side of CR-IP cassette, and high contactness sponge is used to the back side of the cassette. Improved contactness between HMS and imaging plate (IP) by means of the high contactness sponge contributed to improve the resolution power in the check images. A lot of paper which is connected with these information have been reported. Imaging plate ST-III should be used to maintain high sensitivity in the check film image forming method. The same image forming method in the check image established by CR has been introduced into the portal image forming method in order to improve the resolution power. However, as a result, it couldn't acquired high resolution image forming in the portal images because of the combination of ST-III and radiotherapy dose. After several trials, it has been recognized that HR-V imaging plate for mammography is the most useful application to maintain high resolution power in the portal images. Also, it is possible to modify the image quality by changing GS parameter which is one of image processing parameters in CR. Furthermore, in case

  3. Model checking biological systems described using ambient calculus

    DEFF Research Database (Denmark)

    Mardare, Radu Iulian; Priami, Corrado; Qualia, Paola

    2005-01-01

    Model checking biological systems described using ambient calculus. In Proc. of the second International Workshop on Computational Methods in Systems Biology (CMSB04), Lecture Notes in Bioinformatics 3082:85-103, Springer, 2005.......Model checking biological systems described using ambient calculus. In Proc. of the second International Workshop on Computational Methods in Systems Biology (CMSB04), Lecture Notes in Bioinformatics 3082:85-103, Springer, 2005....

  4. Model Checking the Remote Agent Planner

    Science.gov (United States)

    Khatib, Lina; Muscettola, Nicola; Havelund, Klaus; Norvig, Peter (Technical Monitor)

    2001-01-01

    This work tackles the problem of using Model Checking for the purpose of verifying the HSTS (Scheduling Testbed System) planning system. HSTS is the planner and scheduler of the remote agent autonomous control system deployed in Deep Space One (DS1). Model Checking allows for the verification of domain models as well as planning entries. We have chosen the real-time model checker UPPAAL for this work. We start by motivating our work in the introduction. Then we give a brief description of HSTS and UPPAAL. After that, we give a sketch for the mapping of HSTS models into UPPAAL and we present samples of plan model properties one may want to verify.

  5. Simple nonparametric checks for model data fit in CAT

    NARCIS (Netherlands)

    Meijer, R.R.

    2005-01-01

    In this paper, the usefulness of several nonparametric checks is discussed in a computerized adaptive testing (CAT) context. Although there is no tradition of nonparametric scalability in CAT, it can be argued that scalability checks can be useful to investigate, for example, the quality of item

  6. Dynamic State Space Partitioning for External Memory Model Checking

    DEFF Research Database (Denmark)

    Evangelista, Sami; Kristensen, Lars Michael

    2009-01-01

    We describe a dynamic partitioning scheme usable by model checking techniques that divide the state space into partitions, such as most external memory and distributed model checking algorithms. The goal of the scheme is to reduce the number of transitions that link states belonging to different...

  7. Creating Büchi automata for multi-valued model checking

    NARCIS (Netherlands)

    Vijzelaar, Stefan J.J.; Fokkink, Wan J.

    2017-01-01

    In explicit state model checking of linear temporal logic properties, a Büchi automaton encodes a temporal property. It interleaves with a Kripke model to form a state space, which is searched for counterexamples. Multi-valued model checking considers additional truth values beyond the Boolean true

  8. Acoustic emission testing of piston check valves

    International Nuclear Information System (INIS)

    Stewart, D.L.

    1994-01-01

    Based on test experience at Comanche Peak Unit 1, an acoustic emission data evaluation matrix for piston check valves has been developed. The degradations represented in this matrix were selected based on Edwards piston check valve failure data reported in the Nuclear Plant Reliability Data System. Evidence to support this matrix was collected from site test data on a variety of valve types. Although still under refinement, the matrix provides three major attributes for closure verification, which have proven useful in developing test procedures for inservice testing and preventing unnecessary disassembly

  9. Symbolic Dependency Graphs for PCTL Model-Checking

    DEFF Research Database (Denmark)

    Mariegaard, Anders; Larsen, Kim Guldstrand

    2017-01-01

    We consider the problem of model-checking a subset of probabilistic CTL, interpreted over (discrete-time) Markov reward models, allowing the specification of lower bounds on the probability of the set of paths satisfying a cost-bounded path formula. We first consider a reduction to fixed-point co......We consider the problem of model-checking a subset of probabilistic CTL, interpreted over (discrete-time) Markov reward models, allowing the specification of lower bounds on the probability of the set of paths satisfying a cost-bounded path formula. We first consider a reduction to fixed...

  10. Approach to developing a ground-motion design basis for facilities important to safety at Yucca Mountain

    International Nuclear Information System (INIS)

    King, J.L.

    1990-01-01

    This paper discusses a methodology for developing a ground-motion design basis for prospective facilities at Yucca Mountain that are important to safety. The methodology utilizes a guasi-deterministic construct called the 10,000-year cumulative-slip earthquake that is designed to provide a conservative, robust, and reproducible estimate of ground motion that has a one-in-ten chance of occurring during the preclosure period. This estimate is intended to define a ground-motion level for which the seismic design would ensure minimal disruption to operations engineering analyses to ensure safe performance are included

  11. Checking in: An Analysis of the (Lack of) Body Checking in Women's Ice Hockey

    Science.gov (United States)

    Weaving, Charlene; Roberts, Samuel

    2012-01-01

    Despite the growing popularity of women's ice hockey in North America, players continue to face limitations because of the prohibition of body checking. In this paper, we argue from a liberal feminist philosophical perspective that this prohibition reinforces existing traditional stereotypes of female athletes. Because the women's game does not…

  12. 16 CFR 240.12 - Checking customer's use of payments.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Checking customer's use of payments. 240.12 Section 240.12 Commercial Practices FEDERAL TRADE COMMISSION GUIDES AND TRADE PRACTICE RULES GUIDES FOR ADVERTISING ALLOWANCES AND OTHER MERCHANDISING PAYMENTS AND SERVICES § 240.12 Checking customer's use of...

  13. Regular Check-Ups Are Important

    Science.gov (United States)

    ... Attack Wear Red for Heart Health Tools for Pregnant Women, New Moms, Women Considering Pregnancy Be a Healthy ... your community (i.e. a faith-based setting, workplace, school, or civic group) ... screening on National Women’s Check-Up Day (the day after Mother’s Day ...

  14. Checking behavioral conformance of artifacts

    NARCIS (Netherlands)

    Fahland, D.; Leoni, de M.; Dongen, van B.F.; Aalst, van der W.M.P.

    2011-01-01

    The usefulness of process models (e.g., for analysis, improvement, or execution) strongly depends on their ability to describe reality. Conformance checking is a technique to validate how good a given process model describes recorded executions of the actual process. Recently, artifacts have been

  15. Progress realized by numerized Eddy current checking-chains

    International Nuclear Information System (INIS)

    Guerin, F.; Blanchet, A.

    1985-01-01

    Until the last ten years , the tubes of the Steam Generators of the Nuclear Stations were inspected by means of Eddy Current with analogical checkings-chains. HBS Company has perfected a numerized checking-chain allowing transmission up to 300 m of the E.C. signals. In a near future, it will be then possible to do periodical inspections of Steam Generators from cabins located out of the reactor building [fr

  16. A novel cognitive intervention for compulsive checking: Targeting maladaptive beliefs about memory.

    Science.gov (United States)

    Alcolado, Gillian M; Radomsky, Adam S

    2016-12-01

    Compulsive checking is one of the most common symptoms of obsessive-compulsive disorder (OCD). Recently it has been proposed that those who check compulsively may believe their memory is poor, rather than having an actual memory impairment. The current study sought to develop and assess a brief cognitive intervention focused on improving maladaptive beliefs about memory, as they pertain to both checking symptoms and memory performance. Participants (N = 24) with a diagnosis of OCD and clinical levels of checking symptomatology were randomly assigned either to receive two weekly 1-hour therapy sessions or to self-monitor during a similar waitlist period. Time spent checking, checking symptoms, maladaptive beliefs about memory, and visuospatial memory were assessed both pre- and post-treatment/waitlist. Results showed that compared to the waitlist condition, individuals in the treatment condition displayed significant decreases in their maladaptive beliefs about memory and checking symptoms from pre- to post-intervention. They also exhibited increased recall performance on a measure of visuospatial memory. Changes in beliefs about memory were predictors of reduced post-intervention checking, but were not predictive of increased post-intervention memory scores. The lack of long term follow-up data and use of a waitlist control leave questions about the stability and specificity of the intervention. Findings provide preliminary evidence that strategies targeting beliefs about memory may be worthy of inclusion in cognitive-behavioural approaches to treating compulsive checking. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. [Factors Associated with Stress Check Attendance: Possible Effect of Timing of Annual Health Examination].

    Science.gov (United States)

    Ishimaru, Tomohiro; Hattori, Michihiro; Nagata, Masako; Kuwahara, Keisuke; Watanabe, Seiji; Mori, Koji

    2018-01-01

    The stress check program has been part of annual employees' health screening since 2015. Employees are recommended, but not obliged, to undergo the stress check offered. This study was designed to examine the factors associated with stress check attendance. A total of 31,156 Japanese employees who underwent an annual health examination and a stress check service at an Occupational Health Service Center in 2016 participated in this study. Data from the annual health examination and stress check service included stress check attendance, date of attendance (if implemented), gender, age, workplace industry, number of employees at the workplace, and tobacco and alcohol consumption. Data were analyzed using multiple logistic regression. The mean rate of stress check attendance was 90.8%. A higher rate of stress check attendance was associated with a lower duration from the annual health examination, age ≥30 years, construction and transport industry, and 50-999 employees at the workplace. A lower rate of stress check attendance was associated with medical and welfare industry and ≥1,000 employees at the workplace. These findings provide insights into developing strategies for improving the rate of stress check attendance. In particular, stress check attendance may improve if the stress check service and annual health examination are conducted simultaneously.

  18. Development of a butterfly check valve model under natural circulation conditions

    International Nuclear Information System (INIS)

    Rao, Yuxian; Yu, Lei; Fu, Shengwei; Zhang, Fan

    2015-01-01

    Highlights: • Bases on Lim’s swing check valve model, a butterfly check valve model was developed. • The method to quantify the friction torque T F in Li’s model was corrected. • The developed model was implemented into the RELAP5 code and verified. - Abstract: A butterfly check valve is widely used to prevent a reverse flow in the pipe lines of a marine nuclear power plant. Under some conditions, the natural circulation conditions in particular, the fluid velocity through the butterfly check valve might become too low to hold the valve disk fully open, thereby the flow resistance of the butterfly check valve varies with the location of the valve disk and as a result the fluid flow is significantly affected by the dynamic motion of the valve disk. Simulation of a pipe line that includes some butterfly check valves, especially under natural circulation conditions, is thus complicated. This paper focuses on the development of a butterfly check valve model to enhance the capability of the thermal–hydraulic system code and the developed model is implemented into the RELAP5 code. Both steady-state calculations and transient calculations were carried out for the primary loop system of a marine nuclear power plant and the calculation results are compared with the experimental data for verification purpose. The simulation results show an agreement with the experimental data

  19. First Results of a Tandem Terrestrial-Unmanned Aerial mapKITE System with Kinematic Ground Control Points for Corridor Mapping

    Directory of Open Access Journals (Sweden)

    Pere Molina

    2017-01-01

    Full Text Available In this article, we report about the first results of the mapKITE system, a tandem terrestrial-aerial concept for geodata acquisition and processing, obtained in corridor mapping missions. The system combines an Unmanned Aerial System (UAS and a Terrestrial Mobile Mapping System (TMMS operated in a singular way: real-time waypoints are computed from the TMMS platform and sent to the UAS in a follow-me scheme. This approach leads to a simultaneous acquisition of aerial-plus-ground geodata and, moreover, opens the door to an advanced post-processing approach for sensor orientation. The current contribution focuses on analysing the impact of the new, dynamic Kinematic Ground Control Points (KGCPs, which arise inherently from the mapKITE paradigm, as an alternative to conventional, costly Ground Control Points (GCPs. In the frame of a mapKITE campaign carried out in June 2016, we present results entailing sensor orientation and calibration accuracy assessment through ground check points, and precision and correlation analysis of self-calibration parameters’ estimation. Conclusions indicate that the mapKITE concept eliminates the need for GCPs when using only KGCPs plus a couple of GCPs at each corridor end, achieving check point horizontal accuracy of μ E , N ≈ 1.7 px (3.4 cm and μ h ≈ 4.3 px (8.6 cm. Since obtained from a simplified version of the system, these preliminary results are encouraging from a future perspective.

  20. Discrete-time rewards model-checked

    NARCIS (Netherlands)

    Larsen, K.G.; Andova, S.; Niebert, Peter; Hermanns, H.; Katoen, Joost P.

    2003-01-01

    This paper presents a model-checking approach for analyzing discrete-time Markov reward models. For this purpose, the temporal logic probabilistic CTL is extended with reward constraints. This allows to formulate complex measures – involving expected as well as accumulated rewards – in a precise and

  1. Remote preenrollment checking of consent forms to reduce nonconformity.

    Science.gov (United States)

    Journot, Valérie; Pérusat-Villetorte, Sophie; Bouyssou, Caroline; Couffin-Cadiergues, Sandrine; Tall, Aminata; Chêne, Geneviève

    2013-01-01

    In biomedical research, the signed consent form must be checked for compliance with regulatory requirements. Checking usually is performed on site, most frequently after a participant's final enrollment. We piloted a procedure for remote preenrollment consent forms checking. We applied it in five trials and assessed its efficiency to reduce form nonconformity before participant enrollment. Our clinical trials unit (CTU) routinely uses a consent form with an additional copy that contains a pattern that partially masks the participant's name and signature. After completion and signatures by the participant and investigator, this masked copy is faxed to the CTU for checking. In case of detected nonconformity, the CTU suspends the participant's enrollment until the form is brought into compliance. We checked nonconformities of consent forms both remotely before enrollment and on site in five trials conducted in our CTU. We tabulated the number and nature of nonconformities by location of detection: at the CTU or on site. We used these data for a pseudo before-and-after analysis and estimated the efficiency of this remote checking procedure in terms of reduction of nonconformities before enrollment as compared to the standard on-site checking procedure. We searched for nonconformity determinants among characteristics of trials, consent forms, investigator sites, and participants through multivariate logistic regression so as to identify opportunities for improvement in our procedure. Five trials, starting sequentially but running concurrently, with remote preenrollment and on-site checking of consent forms from 415 participants screened in 2006-2009 led to 518 consent forms checked; 94 nonconformities were detected in 75 forms, 75 (80%) remotely and 19 more (20%) on site. Nonconformities infrequently concerned dates of signatures (7%) and information about participants (12%). Most nonconformities dealt with investigator information (76%), primarily contact information

  2. The importance of drug checking outside the context of nightlife in Slovenia.

    Science.gov (United States)

    Sande, Matej; Šabić, Simona

    2018-01-12

    The main purpose of the research was to evaluate the implementation of the drug checking service in Slovenia and to obtain the opinion of users included in harm reduction programmes for high-risk drug users and of drug users in nightlife settings on drug checking, the reasons for drug checking, and their attitude towards adulterants in the drugs that they use. The two final unrepresentative research samples included 102 respondents from harm reduction programmes and 554 respondents from the online sample. The questionnaire was designed based on analysis of the interviews conducted with professionals from the programmes, who took part in the drug checking project, and based on previous research on drug use in nightlife. The main findings related to users' opinions on the drug checking service are that users from both samples perceive drug checking as a contribution to risk reduction and that they find providing information for them about the harmful adulterants and substances that they use very important. In addition, users from both samples considered accessibility of the drug checking service as very important and would be in favour of brief counselling at the collection of the drug sample. One of the salient differences between samples was that nightlife drug users found it more important to recognise substances in the drugs that they use. Drug users from two different samples attach a relatively high importance to the drug checking service, and they consider it to be a contribution to risk reduction. As well as drug users in nightlife settings, high-risk drug users also perceive the drug checking service to be important, which is relevant in the phase of planning drug checking services outside the context of nightlife and for the act of incorporating these services into contemporary harm reduction policy.

  3. Intrinsically safe electrical installations, auxiliary circuits and electric communication equipment

    Energy Technology Data Exchange (ETDEWEB)

    Herms, C D

    1981-11-19

    Technical progress has not stopped short of electrical systems in mining, so that three new chapters are new included in the VDE regulations leaflet No. 0118 on 'Installation of electrical systems in underground coal mining'. The regulations on intrinsically safe electric systems, auxiliary circuits and communication systems are briefly described, and grounds for the regulations are presented. The regulations already take account of European regulations on intrinsic safety which will soon be published in a European Regulation on Mine Explosions. In the chapters on auxiliary circuits and communication systems, protection against direct contact, fires, and explosions is discussed as well as the further goal of reliable signal transmission.

  4. An analysis model of the secondary tunnel lining considering ground-primary support-secondary lining interaction

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Seong-Ho; Chang, Seok-Bue [Yooshin Engineering Corporation, Seoul(Korea); Lee, Sang-Duk [Ajou University, Suwon(Korea)

    2002-06-30

    It is the common practice to over design the reinforcement for the secondary tunnel lining due to the lack of rational insight into the ground loosening loads, and due to the conservative application of the empirical design methods. The main loads of the secondary lining are the ground loosening loads and the ground water pressure, and the ground load is critical in the reinforcement design of the secondary lining in the case of drained tunnel. If the external load is absent around a tunnel. the reasons of the load for secondary tunnel lining are the deterioration of the primary supports such as shotcrete, steel rib, and rock bolts. Accordingly, the analysis method considering the ground-primary supports-secondary lining interaction should be required for the rational design of the secondary tunnel lining. In this paper, the interaction was conceptually described by the simple mass-spring model and the load transfer from the ground and primary supports to the secondary lining is showed by the ground-primary supports-secondary lining reaction curves for the theoretical solution of a circular tunnel, And also, the application of this proposed model to numerical analysis is verified in order to check the potential for the tunnel with the complex analysis conditions. (author). 8 refs., 2 tabs., 7 figs.

  5. The medicines refrigerator and the importance of the cold chain in the safe storage of medicines.

    Science.gov (United States)

    Hatchett, Richard

    2017-10-04

    The medicines refrigerator is a common piece of equipment found in clinical areas. It is used to ensure specific medicines are safely stored within a narrow temperature range in line with manufacturers' instructions; this is usually between +2˚C and +8˚C, and ideally +5˚C. Drugs stored in the medicines refrigerator include: vaccines; insulin; chemotherapy drugs; topical preparations, such as some types of eye drops; and other treatments such as glucagon, which is used to manage severe hypoglycaemia. This article reviews the function of the medicines refrigerator and the checks required by healthcare practitioners to ensure that medicines remain safely stored and their effectiveness is maintained. It also outlines the medicines refrigeration procedure known as the 'cold chain', which includes the use of cold boxes or vaccine carriers to maintain the required temperature of medicines during transport from the manufacturer to user, or between healthcare departments. ©2012 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.

  6. Influence of check dams on debris-flow run-out intensity

    Directory of Open Access Journals (Sweden)

    A. Remaître

    2008-12-01

    Full Text Available Debris flows are very dangerous phenomena claiming thousands of lives and millions of Euros each year over the world. Disaster mitigation includes non-structural (hazard mapping, insurance policies, active structural (drainage systems and passive structural (check dams, stilling basins countermeasures. Since over twenty years, many efforts are devoted by the scientific and engineering communities to the design of proper devices able to capture the debris-flow volume and/or break down the energy. If considerable theoretical and numerical work has been performed on the size, the shape and structure of check dams, allowing the definition of general design criteria, it is worth noting that less research has focused on the optimal location of these dams along the debris-flow pathway.

    In this paper, a methodological framework is proposed to evaluate the influence of the number and the location of the check dams on the reduction of the debris-flow intensity (in term of flow thickness, flow velocity and volume. A debris-flow model is used to simulate the run-out of the debris flow. The model uses the Janbu force diagram to resolve the force equilibrium equations; a bingham fluid rheology is introduced and represents the resistance term. The model has been calibrated on two muddy debris-flow events that occurred in 1996 and 2003 at the Faucon watershed (South French Alps.

    Influence of the check dams on the debris-flow intensity is quantified taking into account several check dams configurations (number and location as input geometrical parameters. Results indicate that debris-flow intensity is decreasing with the distance between the source area and the first check dams. The study demonstrates that a small number of check dams located near the source area may decrease substantially the debris-flow intensity on the alluvial fans.

  7. SAFE Newsletter

    OpenAIRE

    2013-01-01

    The Center of Excellence SAFE – “Sustainable Architecture for Finance in Europe” – is a cooperation of the Center for Financial Studies and Goethe University Frankfurt. It is funded by the LOEWE initiative of the State of Hessen (Landes-Offensive zur Entwicklung wissenschaftlich-ökonomischer Exzellenz). SAFE brings together more than 40 professors and just as many junior researchers who are all dedicated to conducting research in support of a sustainable financial architecture. The Center has...

  8. Overview of Prevention for Water Hammer by Check Valve Action in Nuclear Reactor

    International Nuclear Information System (INIS)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon

    2016-01-01

    Water hammer can cause serious damage to pumping system and unexpected system pressure rise in the pipeline. In nuclear reactor, water hammer can influence on the integrity of safety related system. Water hammer in nuclear reactor have been caused by voiding in normally water-filled lines, steam condensation line containing both steam and water, as well as by rapid check valve action. Therefore, this study focuses on the water hammer by check valve among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. This study focuses on the water hammer by check valve action among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. If the inadvertent pump trip or pipe rupture in high velocity and pressure pipe is predicted, the fast response check valve such as tiled disc, dual disc and nozzle check valve should be installed in the system. If the inadvertent pump trip or pipe rupture in very high velocity and pressure pipe and excessively large revered flow velocity are predicted, the very slowly closing check valve such as controlled closure check valve should be installed in the system

  9. Overview of Prevention for Water Hammer by Check Valve Action in Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Water hammer can cause serious damage to pumping system and unexpected system pressure rise in the pipeline. In nuclear reactor, water hammer can influence on the integrity of safety related system. Water hammer in nuclear reactor have been caused by voiding in normally water-filled lines, steam condensation line containing both steam and water, as well as by rapid check valve action. Therefore, this study focuses on the water hammer by check valve among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. This study focuses on the water hammer by check valve action among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. If the inadvertent pump trip or pipe rupture in high velocity and pressure pipe is predicted, the fast response check valve such as tiled disc, dual disc and nozzle check valve should be installed in the system. If the inadvertent pump trip or pipe rupture in very high velocity and pressure pipe and excessively large revered flow velocity are predicted, the very slowly closing check valve such as controlled closure check valve should be installed in the system.

  10. Efficient Multi-Valued Bounded Model Checking for LTL over Quasi-Boolean Algebras

    OpenAIRE

    Andrade, Jefferson O.; Kameyama, Yukiyoshi

    2012-01-01

    Multi-valued Model Checking extends classical, two-valued model checking to multi-valued logic such as Quasi-Boolean logic. The added expressivity is useful in dealing with such concepts as incompleteness and uncertainty in target systems, while it comes with the cost of time and space. Chechik and others proposed an efficient reduction from multi-valued model checking problems to two-valued ones, but to the authors' knowledge, no study was done for multi-valued bounded model checking. In thi...

  11. SRS Burial Ground Complex: Remediation in Progress

    International Nuclear Information System (INIS)

    Griffin, M.; Crapse, B.; Cowan, S.

    1998-01-01

    Closure of the various areas in the Burial Ground Complex (BGC) represents a major step in the reduction of risk at the Savannah River Site (SRS) and a significant investment of resources. The Burial Ground Complex occupies approximately 195 acres in the central section of the SRS. Approximately 160 acres of the BGC consists of hazardous and radioactive waste disposal sites that require remediation. Of these source acres, one-third have been remediated while two-thirds are undergoing interim or final action. These restoration activities have been carried out in a safe and cost effective manner while minimizing impact to operating facilities. Successful completion of these activities is in large part due to the teamwork demonstrated by the Department of Energy, contractor/subcontractor personnel, and the regulatory agencies. The experience and knowledge gained from the closure of these large disposal facilities can be used to expedite closure of similar facilities

  12. Transient analysis for a system with a tilted disc check valve

    International Nuclear Information System (INIS)

    Jeung, Jaesik; Lee, Kyukwang; Cho, Daegwan

    2014-01-01

    Check valves are used to prevent reverse flow conditions in a variety of systems in nuclear power plants. When a check valve is closed by a reverse flow, the transient load can jeopardize the structural integrity on the piping system and its supports. It may also damage intended function of the in-line components even though the severity of the load differs and depends strongly on types of the check valves. To incorporate the transient load in the piping system, it is very important to properly predict the system response to transients such as a check valve closure accompanied by pump trip and to evaluate the system transient. The one-dimensional transient simulation codes such as the RELAP5/MOD3.3 and TRACE were used. There has not been a single model that integrates the two codes to handle the behavior of a tilted disc check valve, which is designed to mitigate check valve slams by shorting the travel of the disc. In this paper a model is presented to predict the dynamic motion of a tilted disc check valve in the transient simulation using the RELAP5/MOD3.3 code and the model is incorporated in a system transient analysis using control variables of the code. In addition, transient analysis for Essential Service Water (ESW) system is performed using the proposed model and the associated load is evaluated for the system. (author)

  13. Efficient Multi-Valued Bounded Model Checking for LTL over Quasi-Boolean Algebras

    Science.gov (United States)

    Andrade, Jefferson O.; Kameyama, Yukiyoshi

    Multi-valued Model Checking extends classical, two-valued model checking to multi-valued logic such as Quasi-Boolean logic. The added expressivity is useful in dealing with such concepts as incompleteness and uncertainty in target systems, while it comes with the cost of time and space. Chechik and others proposed an efficient reduction from multi-valued model checking problems to two-valued ones, but to the authors' knowledge, no study was done for multi-valued bounded model checking. In this paper, we propose a novel, efficient algorithm for multi-valued bounded model checking. A notable feature of our algorithm is that it is not based on reduction of multi-values into two-values; instead, it generates a single formula which represents multi-valuedness by a suitable encoding, and asks a standard SAT solver to check its satisfiability. Our experimental results show a significant improvement in the number of variables and clauses and also in execution time compared with the reduction-based one.

  14. Stability check source measurements with a secondary standard dosimeter in SSDL-Pakistan

    International Nuclear Information System (INIS)

    Salman, S.; Mahmoud, K.; Orfi, S.D.

    1988-01-01

    The stability check source is an integral part of a Secondary Standard Dosimetry System. The purpose of the stability check source is to confirm that the overall response of the dosimeter has not changed significantly since the instrument was calibrated. In case any change in the sensitivity of the ionization chamber or measuring assembly occurs the same is reflected in the reference check source measurements. Stability check source measurements are taken in a Primary Standard Dosimetry Laboratory (PSDL) at the time of calibration of secondary standard dosimeter and mean time (in seconds) to the reference setting of 50 scale divisions with ambient conditions of air at 20 deg. C, 101.3 kPa and 50% RH is quoted in a calibration certificate. This quoted stability check source time figure is the basis for future confirmation of overall response of the secondary standard dosimeter system. This note presents the results of stability check source measurements carried out in SSDL Pakistan over a period of five years

  15. Safe Zones for Shock-Protection of Fragile Components during Impact-Induced Clatter

    Directory of Open Access Journals (Sweden)

    Suresh Goyal

    2002-01-01

    Full Text Available Clattering motion that occurs when flat objects strike the ground at an oblique angle is studied through a simple, tractable, model of a rigid bar with arbitrary, but symmetric, mass distribution and coefficient of restitution. The maximum velocity changes, or velocity shocks, that occur at various locations of the bar as it clatters to rest, are presented. It is shown that different parts of the bar can be subjected to sequences of velocity changes that are both higher, and lower, than those encountered in a single clatter-free impact. The implication that the drop-tolerance of an electronic product can be increased by configuring it to have ‘safe zones’ – where the velocity shocks are lower – for the placement of fragile components, is analysed. It is shown, through example, that a significant safe zone can be created in the center of the product by configuring it to have a low moment of inertia and by minimizing coefficient of restitution.

  16. Independent checks of linear accelerators equipped with multileaf collimators

    International Nuclear Information System (INIS)

    Pavlikova, I.; Ekendahl, D.; Horakova, I.

    2005-01-01

    National Radiation Protection Institute (NRPI) provides independent checks of therapeutic equipment as a part of state supervision. In the end of 2003, the audit was broaden for linear accelerators equipped with multileaf collimators (MLC). NRPI provides TLD postal audits and on-site independent checks. This contribution describes tests for multileaf collimators and intensity modulated radiation therapy (IMRT) technique that are accomplished within the independent on-site check of linear accelerators. The character and type of tests that are necessary to pursue for multileaf collimator depends on application technique. There are three basic application of the MLC. The first we call 'static MLC' and it serves for replacing conventional blocking or for adjusting the field shape to match the beam's-eye view projection of a planning target volume during an arc rotation of the x-ray beam. This procedure is called conformal radiotherapy. The most advanced technique with MLC is intensity modulated radiation therapy. The dose can be delivered to the patient with IMRT in various different ways: dynamic MLC, segmented MLC and IMRT arc therapy. Independent audits represent an important instrument of quality assurance. Methodology for independent check of static MLC was successfully verified on two types of accelerators: Varian and Elekta. Results from pilot measurements with dynamic MLC imply that the methodology is applicable for Varian accelerators. In the future, the experience with other types of linear accelerators will contribute to renovation, modification, and broaden independent checks methodology. (authors)

  17. Safe lengthening of a drillpipe string by stands

    Energy Technology Data Exchange (ETDEWEB)

    Karapetyan, K.V.; Khrennikov, S.B.; Voyevoda, A.N.

    1979-01-01

    In order to prevent dragging of the block and tackle under the ground block, each drilling rig is equipped with block and tackle lift limiter. However these devices reduce the useful height of the derricks. Studies were carried out to achieve safe conditions for lengthening drillpipe strings with stands and advance of the borehole with a set of drilling stands. The basic precepts of this research were used to design the new drilling rig Uralmash-3000 EUK. In addition an increase of derrick height by 2.5 m was recommended for effective use of production drilling rigs BU-80. In order to lengthen the derrick a special support under the crown block articulated to the upper sections of the feet of the derrick with a frame under the crown block should be used.

  18. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  19. Member Checking: A Tool to Enhance Trustworthiness or Merely a Nod to Validation?

    Science.gov (United States)

    Birt, Linda; Scott, Suzanne; Cavers, Debbie; Campbell, Christine; Walter, Fiona

    2016-06-22

    The trustworthiness of results is the bedrock of high quality qualitative research. Member checking, also known as participant or respondent validation, is a technique for exploring the credibility of results. Data or results are returned to participants to check for accuracy and resonance with their experiences. Member checking is often mentioned as one in a list of validation techniques. This simplistic reporting might not acknowledge the value of using the method, nor its juxtaposition with the interpretative stance of qualitative research. In this commentary, we critique how member checking has been used in published research, before describing and evaluating an innovative in-depth member checking technique, Synthesized Member Checking. The method was used in a study with patients diagnosed with melanoma. Synthesized Member Checking addresses the co-constructed nature of knowledge by providing participants with the opportunity to engage with, and add to, interview and interpreted data, several months after their semi-structured interview. © The Author(s) 2016.

  20. Employees are ambivalent about health checks in the occupational setting

    NARCIS (Netherlands)

    Damman, O.C.; van der Beek, A.J.; Timmermans, D.R.M.

    2015-01-01

    Background: Employees are increasingly provided with preventive health checks. However, participation rates are low and several ethical issues arise, such as a potential perceived threat to autonomy and privacy. Aims: To assess what employees think about preventive health checks in the occupational

  1. Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance.

    Science.gov (United States)

    Narayanasamy, Ganesh; Zalman, Travis; Ha, Chul S; Papanikolaou, Niko; Stathakis, Sotirios

    2015-05-08

    The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose comparisons in a plane, Dosimetry Check system produces isodose lines and dose-volume histograms based on the planning CT images. By exporting the dose distribution from the treatment planning system into the Dosimetry Check system, one is able to make a direct comparison between the calculated dose and the planned dose. The versatility of the software is evaluated with respect to the two IMRT techniques - step and shoot and volumetric arc therapy. The system analyzed measurements made using EPID, PTW seven29, and IBA MatriXX, and an intercomparison study was performed. Plans from patients previously treated at our institution with treated anatomical site on brain, head & neck, liver, lung, and prostate were analyzed using Dosimetry Check system for any anatomical site dependence. We have recommendations and possible precautions that may be necessary to ensure proper QA with the Dosimetry Check system.

  2. First experiences with the LHC BLM sanity checks

    OpenAIRE

    Emery, J; Dehning, B; Effinger, E; Nordt, A; Sapinski, M G; Zamantzas, C

    2010-01-01

    The reliability concerns have driven the design of the Large Hardron Collider (LHC) Beam Loss Monitoring (BLM) system from the early stage of the studies up to the present commissioning and the latest development of diagnostic tools. To protect the system against non-conformities, new ways of automatic checking have been developed and implemented. These checks are regularly and systematically executed by the LHC operation team to ensure that the system status is after each test "as good as ne...

  3. Adding Theoretical Grounding to Grounded Theory: Toward Multi-Grounded Theory

    OpenAIRE

    Göran Goldkuhl; Stefan Cronholm

    2010-01-01

    The purpose of this paper is to challenge some of the cornerstones of the grounded theory approach and propose an extended and alternative approach for data analysis and theory development, which the authors call multi-grounded theory (MGT). A multi-grounded theory is not only empirically grounded; it is also grounded in other ways. Three different grounding processes are acknowledged: theoretical, empirical, and internal grounding. The authors go beyond the pure inductivist approach in GT an...

  4. Epidemiological alteration in pathogens found in ground meat in Iran: unexpected predominance of vancomycin-resistant Enterococcus faecalis

    Directory of Open Access Journals (Sweden)

    Sadeghifard, Nourkhoda

    2015-07-01

    Full Text Available Colonization of the human and animal intestinal tract with potential pathogenic bacteria is correlated with the risk of contamination of food products. The current study analyzed the prevalence of and O157H7 in ground meat in Ilam, Iran. Both index organisms were identified following standard food microbiological methods. For , the susceptibility to vancomycin was tested, and PCR was used to check for the gene. was present in all 24 ground meat samples, with no O157H7 detected in samples. The analysis showed the presence of the gene in 5/24 vancomycin resistant enterococci. In conclusion, this study for the first time demonstrates the presence of vancomycin-resistant enterococci in ground meat in Iran. This observation warrants further epidemiologic investigation and should be followed up in the future.

  5. SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

    International Nuclear Information System (INIS)

    Covington, E; Younge, K; Chen, X; Lee, C; Matuszak, M; Kessler, M; Acosta, E; Orow, A; Filpansick, S; Moran, J; Keranen, W

    2015-01-01

    Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827

  6. SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

    Energy Technology Data Exchange (ETDEWEB)

    Covington, E; Younge, K; Chen, X; Lee, C; Matuszak, M; Kessler, M; Acosta, E; Orow, A; Filpansick, S; Moran, J [University of Michigan Hospital and Health System, Ann Arbor, MI (United States); Keranen, W [Varian Medical Systems, Palo Alto, CA (United States)

    2015-06-15

    Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827.

  7. 21 CFR 1301.93 - Sources of information for employee checks.

    Science.gov (United States)

    2010-04-01

    ... OF MANUFACTURERS, DISTRIBUTORS, AND DISPENSERS OF CONTROLLED SUBSTANCES Employee Screening-Non-Practitioners § 1301.93 Sources of information for employee checks. DEA recommends that inquiries concerning... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Sources of information for employee checks. 1301...

  8. Safe Laser Beam Propagation for Interplanetary Links

    Science.gov (United States)

    Wilson, Keith E.

    2011-01-01

    Ground-to-space laser uplinks to Earth–orbiting satellites and deep space probes serve both as a beacon and an uplink command channel for deep space probes and Earth-orbiting satellites. An acquisition and tracking point design to support a high bandwidth downlink from a 20-cm optical terminal on an orbiting Mars spacecraft typically calls for 2.5 kW of 1030-nm uplink optical power in 40 micro-radians divergent beams.2 The NOHD (nominal ocular hazard distance) of the 1030nm uplink is in excess of 2E5 km, approximately half the distance to the moon. Recognizing the possible threat of high power laser uplinks to the flying public and to sensitive Earth-orbiting satellites, JPL developed a three-tiered system at its Optical Communications Telescope Laboratory (OCTL) to ensure safe laser beam propagation through navigational and near-Earth space.

  9. Behavioral Consistency of C and Verilog Programs Using Bounded Model Checking

    National Research Council Canada - National Science Library

    Clarke, Edmund; Kroening, Daniel; Yorav, Karen

    2003-01-01

    .... We describe experimental results on various reactive present an algorithm that checks behavioral consistency between an ANSI-C program and a circuit given in Verilog using Bounded Model Checking...

  10. Spatial prediction of ground subsidence susceptibility using an artificial neural network.

    Science.gov (United States)

    Lee, Saro; Park, Inhye; Choi, Jong-Kuk

    2012-02-01

    Ground subsidence in abandoned underground coal mine areas can result in loss of life and property. We analyzed ground subsidence susceptibility (GSS) around abandoned coal mines in Jeong-am, Gangwon-do, South Korea, using artificial neural network (ANN) and geographic information system approaches. Spatial data of subsidence area, topography, and geology, as well as various ground-engineering data, were collected and used to create a raster database of relevant factors for a GSS map. Eight major factors causing ground subsidence were extracted from the existing ground subsidence area: slope, depth of coal mine, distance from pit, groundwater depth, rock-mass rating, distance from fault, geology, and land use. Areas of ground subsidence were randomly divided into a training set to analyze GSS using the ANN and a test set to validate the predicted GSS map. Weights of each factor's relative importance were determined by the back-propagation training algorithms and applied to the input factor. The GSS was then calculated using the weights, and GSS maps were created. The process was repeated ten times to check the stability of analysis model using a different training data set. The map was validated using area-under-the-curve analysis with the ground subsidence areas that had not been used to train the model. The validation showed prediction accuracies between 94.84 and 95.98%, representing overall satisfactory agreement. Among the input factors, "distance from fault" had the highest average weight (i.e., 1.5477), indicating that this factor was most important. The generated maps can be used to estimate hazards to people, property, and existing infrastructure, such as the transportation network, and as part of land-use and infrastructure planning.

  11. Reducing Lookups for Invariant Checking

    DEFF Research Database (Denmark)

    Thomsen, Jakob Grauenkjær; Clausen, Christian; Andersen, Kristoffer Just

    2013-01-01

    This paper helps reduce the cost of invariant checking in cases where access to data is expensive. Assume that a set of variables satisfy a given invariant and a request is received to update a subset of them. We reduce the set of variables to inspect, in order to verify that the invariant is still...

  12. Identification of technical guidance related to ground water monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Vogelsberger, R.R.; Smith, E.D.; Broz, M.; Wright, J.C. Jr.

    1987-05-01

    Monitoring of ground water quality is a key element of ground water protection and is mandated by several federal and state laws concerned with water quality or waste management. Numerous regulatory guidance documents and technical reports discuss various aspects of ground water monitoring, but at present there is no single source of guidance on procedures and practices for ground water monitoring. This report is intended to assist US Department of Energy (DOE) officials and facility operating personnel in identifying sources of guidance for developing and implementing ground water monitoring programs that are technically sound and that comply with applicable regulations. Federal statutes and associated regulations were reviewed to identify requirements related to ground water monitoring, and over 160 documents on topics related to ground water monitoring were evaluated for their technical merit, their utility as guidance for regulatory compliance, and their relevance to DOE's needs. For each of 15 technical topics involved in ground water monitoring, the report presents (1) a review of federal regulatory requirements and representative state requirements, (2) brief descriptions of the contents and merits of available guidance documents and technical references, and (3) recommendations of the guidance documents or other technical resources that appear to be most appropriate for use in DOE's monitoring activities. The contents of the report are applicable to monitoring activities involving both radioactive and nonradioactive substances. The main sources of regulatory requirements considered in the report are the Atomic Energy Act (including the Uranium Mill Tailings Radiation Control Act), Resource Conservation and Recovery Act, Comprehensive Environmental Response, Compensation and Liability Act, Safe Drinking Water Act, Toxic Substances Control Act, and Federal Water Pollution Control Act.

  13. Identification of technical guidance related to ground water monitoring

    International Nuclear Information System (INIS)

    Vogelsberger, R.R.; Smith, E.D.; Broz, M.; Wright, J.C. Jr.

    1987-05-01

    Monitoring of ground water quality is a key element of ground water protection and is mandated by several federal and state laws concerned with water quality or waste management. Numerous regulatory guidance documents and technical reports discuss various aspects of ground water monitoring, but at present there is no single source of guidance on procedures and practices for ground water monitoring. This report is intended to assist US Department of Energy (DOE) officials and facility operating personnel in identifying sources of guidance for developing and implementing ground water monitoring programs that are technically sound and that comply with applicable regulations. Federal statutes and associated regulations were reviewed to identify requirements related to ground water monitoring, and over 160 documents on topics related to ground water monitoring were evaluated for their technical merit, their utility as guidance for regulatory compliance, and their relevance to DOE's needs. For each of 15 technical topics involved in ground water monitoring, the report presents (1) a review of federal regulatory requirements and representative state requirements, (2) brief descriptions of the contents and merits of available guidance documents and technical references, and (3) recommendations of the guidance documents or other technical resources that appear to be most appropriate for use in DOE's monitoring activities. The contents of the report are applicable to monitoring activities involving both radioactive and nonradioactive substances. The main sources of regulatory requirements considered in the report are the Atomic Energy Act (including the Uranium Mill Tailings Radiation Control Act), Resource Conservation and Recovery Act, Comprehensive Environmental Response, Compensation and Liability Act, Safe Drinking Water Act, Toxic Substances Control Act, and Federal Water Pollution Control Act

  14. Safe Grid

    Science.gov (United States)

    Chow, Edward T.; Stewart, Helen; Korsmeyer, David (Technical Monitor)

    2003-01-01

    The biggest users of GRID technologies came from the science and technology communities. These consist of government, industry and academia (national and international). The NASA GRID is moving into a higher technology readiness level (TRL) today; and as a joint effort among these leaders within government, academia, and industry, the NASA GRID plans to extend availability to enable scientists and engineers across these geographical boundaries collaborate to solve important problems facing the world in the 21 st century. In order to enable NASA programs and missions to use IPG resources for program and mission design, the IPG capabilities needs to be accessible from inside the NASA center networks. However, because different NASA centers maintain different security domains, the GRID penetration across different firewalls is a concern for center security people. This is the reason why some IPG resources are been separated from the NASA center network. Also, because of the center network security and ITAR concerns, the NASA IPG resource owner may not have full control over who can access remotely from outside the NASA center. In order to obtain organizational approval for secured remote access, the IPG infrastructure needs to be adapted to work with the NASA business process. Improvements need to be made before the IPG can be used for NASA program and mission development. The Secured Advanced Federated Environment (SAFE) technology is designed to provide federated security across NASA center and NASA partner's security domains. Instead of one giant center firewall which can be difficult to modify for different GRID applications, the SAFE "micro security domain" provide large number of professionally managed "micro firewalls" that can allow NASA centers to accept remote IPG access without the worry of damaging other center resources. The SAFE policy-driven capability-based federated security mechanism can enable joint organizational and resource owner approved remote

  15. Aviation System Capacity Program Terminal Area Productivity Project: Ground and Airborne Technologies

    Science.gov (United States)

    Giulianetti, Demo J.

    2001-01-01

    Ground and airborne technologies were developed in the Terminal Area Productivity (TAP) project for increasing throughput at major airports by safely maintaining good-weather operating capacity during bad weather. Methods were demonstrated for accurately predicting vortices to prevent wake-turbulence encounters and to reduce in-trail separation requirements for aircraft approaching the same runway for landing. Technology was demonstrated that safely enabled independent simultaneous approaches in poor weather conditions to parallel runways spaced less than 3,400 ft apart. Guidance, control, and situation-awareness systems were developed to reduce congestion in airport surface operations resulting from the increased throughput, particularly during night and instrument meteorological conditions (IMC). These systems decreased runway occupancy time by safely and smoothly decelerating the aircraft, increasing taxi speed, and safely steering the aircraft off the runway. Simulations were performed in which optimal trajectories were determined by air traffic control (ATC) and communicated to flight crews by means of Center TRACON Automation System/Flight Management System (CTASFMS) automation to reduce flight delays, increase throughput, and ensure flight safety.

  16. Not Just right experiences as ironic result of perseverative checking

    NARCIS (Netherlands)

    van Dis, E.A.M.; van den Hout, M.A.

    2016-01-01

    Objective: patients with obsessive-compulsive disorder (ocD) typically report to have “not just right experiences” (NJRE). up till now it is unclear which behavioral ocD features may give rise to NJREs. We used an induced checking paradigm to experimentally study whether perseverative checking

  17. Hydrochemical and Isotopic Assessment of Ground Water in Eastern Desert, Egypt

    International Nuclear Information System (INIS)

    Atiti, S.Y.; Ali, M.M.; Yousef, L.A.; Dessouki, H.A.

    2011-01-01

    The recharge rate is the most critical factor to ground water resources especially in semi- arid and arid areas. Fourteen representative ground water samples were collected from South Eastern Desert of Egypt and subjected to chemical and isotopic composition. The chemical data reported that, the alkalinity (ph) ranges between 6.5 and 8.5, the salinity of water ranges between 396 and 7874 ppm, sodium is the most dominant cation and chloride is the most dominant anion. The concentration of trace elements (Fe, Pb, Cd, Ni, Cu, Zn, and Mn) was analyzed to evaluate the suitability for drinking and irrigation. Uranium and thorium concentrations were found within the safe limit. Most of ground water was found suitable for drinking water, laundry, irrigation, building, industrial, livestock and poultry. The environmental stable isotopes (D and 18 O) and the radioactive isotope 3 H were evaluated for water samples of the investigated area to focus on the origin of the ground water, sources of recharging and the water rock interaction between aquifers and water. The isotopic compositions of these ground water samples indicated that, there are three different sources of recharge; paleo-water, local precipitation and rain water

  18. Welfare Checks, Drug Consumption, and Health: Evidence from Vancouver Injection Drug Users

    Science.gov (United States)

    Riddell, Chris; Riddell, Rosemarie

    2006-01-01

    This paper investigates the link between welfare payments and drug use among injection drug users. The authors find an increase in the likelihood of an overdose in the days following check arrival, and in the probability of leaving the hospital against medical advice (AMA) on check day. Using the check arrival date as an instrument, we estimate…

  19. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  20. A naturalistic examination of body checking and dietary restriction in women with anorexia nervosa.

    Science.gov (United States)

    Lavender, Jason M; Wonderlich, Stephen A; Crosby, Ross D; Engel, Scott G; Mitchell, James E; Crow, Scott; Peterson, Carol B; Le Grange, Daniel

    2013-08-01

    Body checking has been conceptualized as a behavioral manifestation of the core overvaluation of eating, shape, and weight concerns underlying eating disorder psychopathology. Cognitive-behavioral theories suggest that body checking behaviors may function to maintain dietary restriction. The current study examined the association between body checking frequency and dietary restriction among women with anorexia nervosa (AN) in the natural environment. Women (N = 118) with full or partial AN completed baseline clinical interviews and a two-week ecological momentary assessment protocol, during which they reported on body checking behaviors (i.e., checking whether one's thighs touch; checking joints/bones for fat) and dietary restriction (i.e., 8 waking hours without eating; consuming less than 1200 calories per day). Average daily body checking frequency was positively associated with baseline eating disorder symptoms and body mass index. Daily body checking frequency was associated with both forms of dietary restriction on the same day, as well as the following day. Results support the theorized association between body checking and overvaluation of shape and weight, and suggest that targeting such behaviors in treatment may have utility in reducing dietary restriction. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Development and testing of techniques for in-ground stabilization, size reduction, and safe removal of radioactive wastes stored in containments buried in ground

    International Nuclear Information System (INIS)

    Halliwell, Stephen; Christodoulou, Apostolos

    2013-01-01

    Since the 1950's radioactive wastes from a number of laboratories have been stored below ground at the Hanford site, Washington State, USA, in vertical pipe units (VPUs) made of five 200 litre drums without tops or bottoms, and in caissons, made out of corrugated pipe, or concrete and typically 2,500 mm in diameter. The VPU's are buried of the order of 2,100 mm below grade, and the caissons are buried of the order of 6,000 mm below grade. The waste contains fuel pieces, fission products, and a range of chemicals used in the laboratory processes. This can include various energetic reactants such as un-reacted sodium potassium (NaK), potassium superoxide (KO 2 ), and picric acid, as well as quantities of other liquids. The integrity of the containments is considered to present unacceptable risks from leakage of radioactivity to the environment. This paper describes the successful development and full scale testing of in-ground augering equipment, grouting systems and removal equipment for remediation and removal of the VPUs, and the initial development work to test the utilization of the same basic augering and grouting techniques for the stabilization, size reduction and removal of caissons. (authors)

  2. Model Checking Timed Automata with Priorities using DBM Subtraction

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Pettersson, Paul

    2006-01-01

    In this paper we describe an extension of timed automata with priorities, and efficient algorithms to compute subtraction on DBMs (difference bounded matrices), needed in symbolic model-checking of timed automata with priorities. The subtraction is one of the few operations on DBMs that result...... in a non-convex set needing sets of DBMs for representation. Our subtraction algorithms are efficient in the sense that the number of generated DBMs is significantly reduced compared to a naive algorithm. The overhead in time is compensated by the gain from reducing the number of resulting DBMs since...... this number affects the performance of symbolic model-checking. The uses of the DBM subtraction operation extend beyond timed automata with priorities. It is also useful for allowing guards on transitions with urgent actions, deadlock checking, and timed games....

  3. THE INFORMATION SYSTEM TO SUPPORT SAFE FOOD PRODUCTION IN CATTLE SECTOR

    Directory of Open Access Journals (Sweden)

    Janez JERETINA

    2011-01-01

    Full Text Available In the year 2006 we started with the development of computerized system for monitoring the veterinarian treatments to support safe food production in cattle sector. Veterinary database and web application which will be used by PC or handhelds were created. Additionally the code listing of diseases was built up with technical support of Veterinary Faculty. The idea was that all treatments should be registered into database, connected to the database of Animal Identification and Registration Service (SIR. Slaughterhouses which are connected to SIR regularly check the identity of incoming animals. According to our project they are warned if the withdrawal period is not respected or health status is not suitable. The response time of slaughterhouses, dairy or other official authorities will be reduced in these cases. The suggested model upgrades the system of traceability and helps the veterinarians at their professional work, too. All the data will be accessible to breeders and other agricultural services.

  4. A review of historical check valve failure data

    International Nuclear Information System (INIS)

    Casada, D.A.; Todd, M.D.

    1992-01-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost, and decreased system availability. In response, additional attention has been given to check valves by utilities, as well as the US Nuclear Regulatory Commission (NRC) and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient of an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. Oak Ridge National Laboratory is currently conducting a detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are being considered during the review, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions. This work is being carried out under the auspices of the NRC's Nuclear Plant Aging Research program. At this time, the study is approximately 50% complete. All failure records have been reviewed and categorized, and preliminary tabulation and correlation of data is underway. The bulk of the tabulation and correlation portion of the work is expected to be completed by the end of June 1992. A report draft is expected in the fall of 1992

  5. Statistical Model Checking for Biological Systems

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Legay, Axel

    2014-01-01

    Statistical Model Checking (SMC) is a highly scalable simulation-based verification approach for testing and estimating the probability that a stochastic system satisfies a given linear temporal property. The technique has been applied to (discrete and continuous time) Markov chains, stochastic...

  6. Model checking mobile ad hoc networks

    NARCIS (Netherlands)

    Ghassemi, Fatemeh; Fokkink, Wan

    2016-01-01

    Modeling arbitrary connectivity changes within mobile ad hoc networks (MANETs) makes application of automated formal verification challenging. We use constrained labeled transition systems as a semantic model to represent mobility. To model check MANET protocols with respect to the underlying

  7. Political and judicial checks on corruption

    DEFF Research Database (Denmark)

    Alt, James E.; Lassen, David Dreyer

    2008-01-01

    This paper investigates the effects of checks and balances on corruption. Within a presidential system, effective separation of powers is achieved under a divided government, with the executive and legislative branches being controlled by different political parties. When government is unified...

  8. PREREQUISITE PROGRAMMES IN OWN CHECKS IN STATUTORY AND VOLUNTARY LEGISLATION

    Directory of Open Access Journals (Sweden)

    E. Guidi

    2012-08-01

    Full Text Available Prerequisite Programmes approach is a requirement for implementing a correct own check plan. This new approach, born according to the European Legislation, is completely recognized by third Nation Authorities and private Inspection and Accreditation Bodies. This method is the basis to verify if an own check system is under control and to verify if corrective actions are built up to warrant hygienic production standards. The present work demonstrate that a correct own check plan is built up only by a Pre Requisites Program approach. The new UNI EN ISO 22000:2005 standard describe this concept specifying the difference between PRP and CCP.

  9. Towards an automated checked baggage inspection system augmented with robots

    Science.gov (United States)

    DeDonato, Matthew P.; Dimitrov, Velin; Padır, Taskin

    2014-05-01

    We present a novel system for enhancing the efficiency and accuracy of checked baggage screening process at airports. The system requirements address the identification and retrieval of objects of interest that are prohibited in a checked luggage. The automated testbed is comprised of a Baxter research robot designed by Rethink Robotics for luggage and object manipulation, and a down-looking overhead RGB-D sensor for inspection and detection. We discuss an overview of current system implementations, areas of opportunity for improvements, robot system integration challenges, details of the proposed software architecture and experimental results from a case study for identifying various kinds of lighters in checked bags.

  10. Preventing the threat of credit-card fraud: Factors influencing cashiers' identification-checking behavior.

    Science.gov (United States)

    Downing, Christopher; Howard, E Henry; Goodwin, Christina; Geller, E Scott

    2016-01-01

    Two studies examined factors influencing cashiers' identification (ID)-checking behavior in order to inform the development of interventions to prevent credit-card fraud. In both studies, research assistants made credit purchases in various stores and noted the cashiers' ID-checking behavior. In the first study, the store type, whether the cashier swiped the credit/debit card, the amount of the purchase, and whether the credit/debit card was signed significantly influenced ID-checking behavior. In the second study, an A-B-A design was used to evaluate the impact of a "Check my ID" prompt placed on the credit/debit card. The prompt increased cashiers' ID-checking behavior from 5.9% at Baseline to 10.3% during the Intervention. When the prompt was removed, the cashiers' ID-checking behavior decreased to 7.2%. Implications for further intervention research to prevent credit-card fraud are discussed.

  11. Radiation systems for luggage and parcel checks

    International Nuclear Information System (INIS)

    Honomichl, V.

    1989-01-01

    The current radioscopic systems of luggage check in air traffic are based on the principle of intensifying the brightness of half-tone images on the fluorescent screen of an image intensifier, or use of very sensitive pick-up tubes with digital image processing. Computers are used for signal processing and the image is produced on a display unit. Sources of continuous or pulse X-ray radiation are used. The signals from the detector are amplified, converted and stored in a buffer and then displayed. The scanning systems use a narrow beam or, to improve rapidity and sensitivity of scanning, a sector beam of radiation. Equipment is described from Heinemann (FRG) featuring a band of 576 or 768 detectors and microprocessor controlled semiconductor tv cameras. Characteristics are also presented of equipment from Aeradio Ltd (U.K.) and Philips (FRG) companies. Attention is devoted to equipment from American Science and Engineering (U.S.) showing high quality imaging even at low radiation doses. Briefly described are portable check systems for inspection of small luggage and parcels. Characteristics are presented of systems for checking vehicles and containers in naval, air, rail and road transport. The principles and performance are described of the systems. (J.B.). 4 figs

  12. Who uses NHS health checks? Investigating the impact of ethnicity and gender and method of invitation on uptake of NHS health checks.

    Science.gov (United States)

    Cook, Erica J; Sharp, Chloe; Randhawa, Gurch; Guppy, Andy; Gangotra, Raj; Cox, Jonathon

    2016-01-20

    NHS Health Checks is a national risk assessment prevention programme for all individuals aged 40-74 that reside in England. Through the systematic assessment of an individual's ten year disease risk, this programme aims to provide early identification and subsequent management of this risk. However, there is limited evidence on how socio-demographic factors impact on uptake and what influence the invitation method has on uptake to this programme. NHS Health Check data from April 2013 to March 2014 was analysed (N = 50,485) for all 30 GP Practices in Luton, a culturally diverse town in England, UK. Data was collected for age, ethnicity, uptake (attendance and non attendance) and invitation method (letter written, verbal face-to-face, telephone). Actual usage of NHS Health Checks was determined for each ethnic group of the population and compared using Chi-square analysis. The overall uptake rate for Luton was 44 %, markedly lower that the set target of 50-75 %. The findings revealed a variation of uptake in relation to age, gender, level of deprivation. Ethnicity and gender variations were also found, with 'White British' 'Black Caribbean' and 'Indian' patients most likely to take up a NHS Health Check. However, patients from 'Any Other White Background' and 'Black African' were significantly less likely to uptake an NHS Health Check compared to all other ethnic groups. Ethnicity and gender differences were also noted in relation to invitation method. The findings revealed that different invitation methods were effective for different ethnic and gender groups. Therefore, it is suggested that established protocols of invitation are specifically designed for maximizing the response rate for each population group. Future research should now focus on uncovering the barriers to uptake in particular culturally diverse population groups to determine how public health teams can better engage with these communities.

  13. Model Checking Feature Interactions

    DEFF Research Database (Denmark)

    Le Guilly, Thibaut; Olsen, Petur; Pedersen, Thomas

    2015-01-01

    This paper presents an offline approach to analyzing feature interactions in embedded systems. The approach consists of a systematic process to gather the necessary information about system components and their models. The model is first specified in terms of predicates, before being refined to t...... to timed automata. The consistency of the model is verified at different development stages, and the correct linkage between the predicates and their semantic model is checked. The approach is illustrated on a use case from home automation....

  14. Functional check of telescoping transfer pumps

    International Nuclear Information System (INIS)

    Sharpe, C.L.

    1994-01-01

    Activities are defined which constitute a functional check of a telescoping transfer pump (TTP). This report is written to the Procedures group of HLW and particularly applies to those TTP's which are the sole means of emergency transfer from a HLW waste tank

  15. PVeStA: A Parallel Statistical Model Checking and Quantitative Analysis Tool

    KAUST Repository

    AlTurki, Musab

    2011-01-01

    Statistical model checking is an attractive formal analysis method for probabilistic systems such as, for example, cyber-physical systems which are often probabilistic in nature. This paper is about drastically increasing the scalability of statistical model checking, and making such scalability of analysis available to tools like Maude, where probabilistic systems can be specified at a high level as probabilistic rewrite theories. It presents PVeStA, an extension and parallelization of the VeStA statistical model checking tool [10]. PVeStA supports statistical model checking of probabilistic real-time systems specified as either: (i) discrete or continuous Markov Chains; or (ii) probabilistic rewrite theories in Maude. Furthermore, the properties that it can model check can be expressed in either: (i) PCTL/CSL, or (ii) the QuaTEx quantitative temporal logic. As our experiments show, the performance gains obtained from parallelization can be very high. © 2011 Springer-Verlag.

  16. CheckMATE 2: From the model to the limit

    Science.gov (United States)

    Dercks, Daniel; Desai, Nishita; Kim, Jong Soo; Rolbiecki, Krzysztof; Tattersall, Jamie; Weber, Torsten

    2017-12-01

    We present the latest developments to the CheckMATE program that allows models of new physics to be easily tested against the recent LHC data. To achieve this goal, the core of CheckMATE now contains over 60 LHC analyses of which 12 are from the 13 TeV run. The main new feature is that CheckMATE 2 now integrates the Monte Carlo event generation via MadGraph5_aMC@NLO and Pythia 8. This allows users to go directly from a SLHA file or UFO model to the result of whether a model is allowed or not. In addition, the integration of the event generation leads to a significant increase in the speed of the program. Many other improvements have also been made, including the possibility to now combine signal regions to give a total likelihood for a model.

  17. Robotic Ground-Penetrating-Radar (GPR) Surveys to Support the 2014 Greenland Inland Traverse

    Science.gov (United States)

    2016-06-01

    return via the same route to Thule in late May for over- winter equipment storage. The first 100 km of the route onto the main ice cap is ridden with...vehicle has a nominal ground pressure of 20 kPa through 0.51 m diameter all-terrain vehicle (ATV) tires . Yeti there- fore can drive safely over most

  18. 48 CFR 22.406-7 - Compliance checking.

    Science.gov (United States)

    2010-10-01

    ... SOCIOECONOMIC PROGRAMS APPLICATION OF LABOR LAWS TO GOVERNMENT ACQUISITIONS Labor Standards for Contracts... inspections to check type of work performed, number and classification of workers, and fulfillment of posting...

  19. SOLA-LOOP analysis of a back pressure check valve

    International Nuclear Information System (INIS)

    Travis, J.R.

    1984-01-01

    The SOLA-LOOP computer code for transient, nonequilibrium, two-phase flows in networks has been coupled with a simple valve model to analyze a feedwater pipe breakage with a back-pressure check valve. Three tests from the Superheated Steam Reactor Safety Program Project (PHDR) at Kahl, West Germany, are analyzed, and the calculated transient back-pressure check valve behavior and fluid dynamics effects are found to be in excellent agreement with the experimentally measured data

  20. Development of a stainless steel check valve for cryogenic applications

    NARCIS (Netherlands)

    Veenstra, T.T.; Venhorst, G.C.F.; Venhorst, G.C.F.; Burger, Johannes Faas; Holland, Herman J.; ter Brake, Hermanus J.M.; Sirbi, A.; Rogalla, Horst

    2007-01-01

    This paper describes the development of a check valve for use in a sorption compressor that will drive a 10 mW 4.5 K Joule–Thomson cryocooler. For the check valve extremely low backflow rates are tolerable at an operating temperature of the valve of 50 K. To fulfill these requirements, the sealing

  1. Gender Check - veel kord soolisusest Ida-Euroopa kunstis / Mare Tralla

    Index Scriptorium Estoniae

    Tralla, Mare, 1967-

    2010-01-01

    Novembris 2010 Viinis toimunud konverentsist, kus analüüsiti näituse "Gender Check. Feminiinsus ja maskuliinsus Ida-Euroopa kunstis" kogemust ning sellele eelnenud ja järgnenud uurimistöö tulemusi. Esitleti artiklite kogumikku "Gender check: a reader : art and theory in Eastern Europe". "Gender Checki" projekti edasisest saatusest ja mõjust

  2. Fraud by using a check | Azarian | Journal of Fundamental and ...

    African Journals Online (AJOL)

    If someone used check as a tool to fraud and looting of property of others, should they just be subject to check law, and according to the provisions of the law are prosecuted? Are crook people the same as honorable merchants that due to some unwanted changes and fluctuations in the market and social conditions

  3. Type checking with open type functions

    DEFF Research Database (Denmark)

    Schrijvers, Tom; Jones, Simon Peyton; Chakravarty, Manual

    2008-01-01

    We report on an extension of Haskell with open type-level functions and equality constraints that unifies earlier work on GADTs, functional dependencies, and associated types. The contribution of the paper is that we identify and characterise the key technical challenge of entailment checking; an...

  4. Slicing AADL specifications for model checking

    NARCIS (Netherlands)

    Odenbrett, M.R.; Nguyen, V.Y.; Noll, T.

    2010-01-01

    To combat the state-space explosion problem in model checking larger systems, abstraction techniques can be employed. Here, methods that operate on the system specification before constructing its state space are preferable to those that try to minimize the resulting transition system as they

  5. CAREN-4, ENDF/B Utility, Discontinuity Check at Resonance Region Boundary. CHECK-4, ENDF/B Utility, Structure Consistency Check and Format Check. CRECT, ENDF/B Utility, Data Correlation and Data Update. DICT-4, ENDF/B Utility, Section Table of Contents Generator. LISTF-4, ENDF/B Utility, Data Listing. RIGEL-4, ENDF/B Utility, Data Retrieval, BCD to BIN Conversion. SUMUP-4, ENDF/B Utility, Partial Cross-Sections Sum Check Against Tot Cross-Sections

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1975-08-01

    Description of problem or function: These programs are updated versions of ENDF/B checking, retrieval, and display codes capable of processing the Version-IV data files. RIGEL4 retrieves ENDF/B data and changes mode (BCD-BIN) or arrangement. Updated version processes decay data (mf=1, mt=457) and error files. CHECK4 checks the structure, consistency, and formats of ENDF data files. Updated version recognizes newly defined mt and mf numbers, checks mt=457 and the formats of the error files, contains RSIC photon file changes. SUMUP4 checks whether partial cross sections add up to the total. Updated version flags grid points present in the partial cross section, absent in the total. LISTF4 produces interpreted listings of ENDF/B data. Updated version lists mt=457, skips over error files, contains minor corrections. PLOTF4 produces plots of ENDF/B data. Updated version plots mt=457, skips over error files, contains minor corrections. RESEND processes ENDF materials with resonance parameters into a pointwise form. Capability of processing Adler-Adler parameters added. CRECT corrects ENDF/B data files. DICT4 generates a section table of contents (dictionary) for ENDF/B materials. CAREN4 tests for discontinuities across the limits of resonance ranges of an ENDF/B material. Updated version contains minor corrections.

  6. Radiotherapy treatment checking procedures throughout Australasia: results of a survey

    International Nuclear Information System (INIS)

    Duggan, L.; Kron, T.; Howlett, S.

    1996-01-01

    In July 1995, a questionnaire was forwarded to thirty two physicists overseeing Radiation Oncology Departments and brachytherapy in hospitals throughout Australia and New Zealand. From the thirty seven hospitals reached by this survey, details were gathered on thirty hospitals, including the Newcastle In most radiotherapy centres where treatment planning is performed by radiation therapists, at least some of the treatment sheets and their calculations are double checked by radiotherapy physicists. While 23% checked the treatment sheets of all patients, in the majority of centres physicists were found to check only a minor selection, that is, less than 20% of all treatment sheets. Only in six centres physicists were not involved. 5 refs., 4 tabs., 5 figs

  7. Discussion on the installation checking method of precast composite floor slab with lattice girders

    Science.gov (United States)

    Chen, Li; Jin, Xing; Wang, Yahui; Zhou, Hele; Gu, Jianing

    2018-03-01

    Based on the installation checking requirements of China’s current standards and the international norms for prefabricated structural precast components, it proposed an installation checking method for precast composite floor slab with lattice girders. By taking an equivalent composite beam consisted of a single lattice girder and the precast concrete slab as the checking object, compression instability stress of upper chords and yield stress of slab distribution reinforcement at the maximum positive moment, tensile yield stress of upper chords, slab normal section normal compression stress and shear instability stress of diagonal bars at the maximum negative moment were checked. And the bending stress and deflection of support beams, strength and compression stability bearing capacity of the vertical support, shear bearing capacity of the bolt and compression bearing capacity of steel tube wall at the bolt were checked at the same time. Every different checking object was given a specific load value and load combination. Application of installation checking method was given and testified by example.

  8. Prediction and comparison of noise levels from ground and elevated flare systems

    International Nuclear Information System (INIS)

    Obasi, E.

    2009-01-01

    Flaring is a process to dispose of hydrocarbons during clean-up, emergency shut downs or dispose a small volume waste streams of mixed gasses that cannot easily or safely be separated. This presentation discussed flaring as a noise issue. It focused on flaring noise characterization; flare noise modeling; flare sound power levels; and flare sound pressure level comparison at a distance of 1.5 km. The presentation included a photograph of flaring at a gas plant in Nigeria. The presentation listed some of the potential health effects associated with long term exposure to excessive noise, such as hearing loss; headaches; stress; fatigue; sleep disturbance; and high blood pressure. Companies flare gas to dispose waste gases in a safe and reliable manner through combustion and to depressurize gas lines during maintenance and emergencies. This presentation also discussed ground and elevated flares; components of flare noise characterization; and key factors affecting flare noise. A model to predict flaring noise was also presented. It demonstrated that at the same gas mass flow rate, the noise level from elevated flare stacks are significantly higher than ground flares. tabs., figs.

  9. Prediction and comparison of noise levels from ground and elevated flare systems

    Energy Technology Data Exchange (ETDEWEB)

    Obasi, E. [Stantec Consulting Ltd., Surrey, BC (Canada)

    2009-07-01

    Flaring is a process to dispose of hydrocarbons during clean-up, emergency shut downs or dispose a small volume waste streams of mixed gasses that cannot easily or safely be separated. This presentation discussed flaring as a noise issue. It focused on flaring noise characterization; flare noise modeling; flare sound power levels; and flare sound pressure level comparison at a distance of 1.5 km. The presentation included a photograph of flaring at a gas plant in Nigeria. The presentation listed some of the potential health effects associated with long term exposure to excessive noise, such as hearing loss; headaches; stress; fatigue; sleep disturbance; and high blood pressure. Companies flare gas to dispose waste gases in a safe and reliable manner through combustion and to depressurize gas lines during maintenance and emergencies. This presentation also discussed ground and elevated flares; components of flare noise characterization; and key factors affecting flare noise. A model to predict flaring noise was also presented. It demonstrated that at the same gas mass flow rate, the noise level from elevated flare stacks are significantly higher than ground flares. tabs., figs.

  10. Soft Computing Approach to Evaluate and Predict Blast-Induced Ground Vibration

    Science.gov (United States)

    Khandelwal, Manoj

    2010-05-01

    Drilling and blasting is still one of the major economical operations to excavate a rock mass. The consumption of explosive has been increased many folds in recent years. These explosives are mainly used for the exploitation of minerals in mining industry or the removal of undesirable rockmass for community development. The amount of chemical energy converted into mechanical energy to fragment and displace the rockmass is minimal. Only 20 to 30% of this explosive energy is utilized for the actual fragmentation and displacement of rockmass and rest of the energy is wasted in undesirable ill effects, like, ground vibration, air over pressure, fly rock, back break, noise, etc. Ground vibration induced due to blasting is very crucial and critical as compared to other ill effects due to involvement of public residing in the close vicinity of mining sites, regulating and ground vibration standards setting agencies together with mine owners and environmentalists and ecologists. Also, with the emphasis shifting towards eco-friendly, sustainable and geo-environmental activities, the field of ground vibration have now become an important and imperative parameter for safe and smooth running of any mining and civil project. The ground vibration is a wave motion, spreading outward from the blast like ripples spreading outwards due to impact of a stone dropped into a pond of water. As the vibration passes through the surface structures, it induces vibrations in those structures also. Sometimes, due to high ground vibration level, dwellings may get damaged and there is always confrontation between mine management and the people residing in the surroundings of the mine area. There is number of vibration predictors available suggested by different researchers. All the predictors estimate the PPV based on mainly two parameters (maximum charge used per delay and distance between blast face to monitoring point). However, few predictors considered attenuation/damping factor too. For

  11. Polarity Checks in Sectors 23 & 78

    CERN Document Server

    Calaga, R; Lamont, M; Ponce, L; Sun, Y; Tomás, R; Venturini-Delsolaro, W; Zimmermann, F

    2009-01-01

    During the first three LHC synchronization tests on August 10, August 24, and September 7, 2008, linear and higher-order polarity checks were performed with beam 1 in Sector 23 and beam 2 in Sector 78. The main principle of these checks was to launch free betatron oscillations and use the difference trajectory measurements with respect to inverted polarities of circuits under investigation. In the case of zero nominal strength for a circuit, a finite value was introduced. The magnet circuits subjected to these tests were the QT and QTL trim quadrupoles, the MQS skew quadrupoles, the SF and SD arc sextupole circuits, the MCS b3 spool pieces, the OD and OF Landau octupoles, and the MSS skew sextupoles. For some of these circuits sensitivity was enhanced by introducing large momentum offsets. To detect and remove improve spurious contributions from initially off-center orbits, four sets of trajectories were recorded, namely with and without oscillation, and with two magnet strength settings, respectively. We rep...

  12. Are Detox Diets Safe?

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Are Detox Diets Safe? KidsHealth / For Teens / Are Detox Diets ... seguras las dietas de desintoxicación? What Is a Detox Diet? The name sounds reassuring — everyone knows that ...

  13. SU-D-BRD-01: An Automated Physics Weekly Chart Checking System Supporting ARIA

    Energy Technology Data Exchange (ETDEWEB)

    Chang, X; Yang, D [Washington University in St Louis, St Louis, MO (United States)

    2015-06-15

    Purpose: A software tool was developed in this study to perform automatic weekly physics chart check on the patient data in ARIA. The tool accesses the electronic patient data directly from ARIA server and checks the accuracy of treatment deliveries, and generates reports which summarize the delivery history and highlight the errors. Methods: The tool has four modules. 1) The database interface is designed to directly access treatment delivery data from the ARIA database before reorganizing the data into the patient chart tree (PCT). 2) PCT is a core data structure designed to store and organize the data in logical hierarchies, and to be passed among functions. 3) The treatment data check module analyzes the organized data in PCT and stores the checking results into PCT. 4) Report generation module generates reports containing the treatment delivery summary, chart checking results and plots of daily treatment setup parameters (couch table positions, shifts of image guidance). The errors that are found by the tool are highlighted with colors. Results: The weekly check tool has been implemented in MATLAB and clinically tested at two major cancer centers. Javascript, cascading style sheets (CSS) and dynamic HTML were employed to create the user-interactive reports. It takes 0.06 second to search the delivery records of one beam with PCT and compare the delivery records with beam plan. The reports, saved in the HTML files on shared network folder, can be accessed by web browser on computers and mobile devices. Conclusion: The presented weekly check tool is useful to check the electronic patient treatment data in Varian ARIA system. It could be more efficient and reliable than the manually check by physicists. The work was partially supported by a research grant from Varian Medical System.

  14. SU-D-BRD-01: An Automated Physics Weekly Chart Checking System Supporting ARIA

    International Nuclear Information System (INIS)

    Chang, X; Yang, D

    2015-01-01

    Purpose: A software tool was developed in this study to perform automatic weekly physics chart check on the patient data in ARIA. The tool accesses the electronic patient data directly from ARIA server and checks the accuracy of treatment deliveries, and generates reports which summarize the delivery history and highlight the errors. Methods: The tool has four modules. 1) The database interface is designed to directly access treatment delivery data from the ARIA database before reorganizing the data into the patient chart tree (PCT). 2) PCT is a core data structure designed to store and organize the data in logical hierarchies, and to be passed among functions. 3) The treatment data check module analyzes the organized data in PCT and stores the checking results into PCT. 4) Report generation module generates reports containing the treatment delivery summary, chart checking results and plots of daily treatment setup parameters (couch table positions, shifts of image guidance). The errors that are found by the tool are highlighted with colors. Results: The weekly check tool has been implemented in MATLAB and clinically tested at two major cancer centers. Javascript, cascading style sheets (CSS) and dynamic HTML were employed to create the user-interactive reports. It takes 0.06 second to search the delivery records of one beam with PCT and compare the delivery records with beam plan. The reports, saved in the HTML files on shared network folder, can be accessed by web browser on computers and mobile devices. Conclusion: The presented weekly check tool is useful to check the electronic patient treatment data in Varian ARIA system. It could be more efficient and reliable than the manually check by physicists. The work was partially supported by a research grant from Varian Medical System

  15. The B4 school check behaviour measures: findings from the Hawke's Bay evaluation.

    Science.gov (United States)

    Hedley, Cath; Thompson, Shona; Morris Matthews, Kay; Pentecost, Mandy; Wivell, Judy; Frost, Ariana Stockdale; Morris, Helen

    2012-11-01

    The Before (B4) School Check is a free health and development check delivered by specifically trained nurses to four year old children throughout New Zealand, aimed to identify and address any health, behavioural, social or developmental concerns that could affect a child's ability to get the most benefit from school. Reported here are the results of an evaluation of the B4 School Checks in Hawke's Bay, focusing specifically on children assessed at the 84 School Check with behaviour issues as determined by the Strengths and Difficulties Questionnaire (SDQ). Health Hawke's Bay (HHB) records were reviewed to understand the number and demographics of the children assessed with behaviour issues at the B4 School Checks up to 31 August 2011, and the interventions to which they were referred. Telephone Interviews were conducted with 36 parents/caregivers of these children to address the questions, what difference did the B4 School Check make to children assessed with behaviour issues and what aspects of the B4 School Check delivery contributed to successful outcomes for these children? Results showed that child behaviour issues in Hawke's Bay were identified in more boys than girls and concentrated in more deprived families. Māori children were represented in numbers disproportional to the regional population. The majority of referrals for child behaviour directed parents/caregivers to non-governmental organisations for family support and parenting programmes. Thematic analysis was applied to the qualitative data derived from the interviews with parents/caregivers and results indicated high levels of satisfaction with the B4 School Check for behaviour and the referred outcomes. Implications for nursing practice arise from these findings in that they identify factors which contribute to what does and does not work well for achieving successful outcomes from the B4 School Check for behaviour.

  16. checkCIF/PLATON report Datablock: Sm

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  17. checkCIF/PLATON report Datablock: neu

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  18. checkCIF/PLATON report Datablock: shelxl

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  19. checkCIF/PLATON report Datablock: 6

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  20. checkCIF/PLATON report Datablock: 2

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  1. checkCIF/PLATON report Datablock: sm

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  2. Contextual Challenges to Safe Surgery in a Resource-limited Setting: A Multicenter, Multiprofessional Qualitative Study.

    Science.gov (United States)

    Scott, John W; Lin, Yihan; Ntakiyiruta, Georges; Mutabazi, Zeta A; Davis, William Austin; Morris, Megan A; Smink, Douglas S; Riviello, Robert; Yule, Steven

    2018-03-01

    Safe surgery should be available to all patients, no matter the setting. The purpose of this study was to explore the contextual-specific challenges to safe surgical care encountered by surgeons and surgical teams in many in low- and middle-income countries (LMICs), and to understand the ways in which surgical teams overcome them. Optimal surgical performance is highly complex and requires providers to integrate and communicate information regarding the patient, task, team, and environment to coordinate team-based care that is timely, effective, and safe. Resource limitations common to many LMICs present unique challenges to surgeons operating in these environments, but have never been formally described. Using a grounded theory approach, we interviewed 34 experienced providers (surgeons, anesthetists, and nurses) at the 4 tertiary referral centers in Rwanda, to understand the challenges to safe surgical care and strategies to overcome them. Interview transcripts were coded line-by-line and iteratively analyzed for emerging themes until thematic saturation was reached. Rwandan-described challenges related to 4 domains: physical resources, human resources, overall systems support, and communication/language. The majority of these challenges arose from significant variability in either the quantity or quality of these domains. Surgical providers exhibited examples of resilient strategies to anticipate, monitor, respond to, and learn from these challenges. Resource variability rather than lack of resources underlies many contextual challenges to safe surgical care in a LMIC setting. Understanding these challenges and resilient strategies to overcome them is critical for both LMIC surgical providers and surgeons from HICs working in similar settings.

  3. Independent procedure of checking dose calculations using an independent calculus algorithm

    International Nuclear Information System (INIS)

    Perez Rozos, A.; Jerez Sainz, I.; Carrasco Rodriguez, J. L.

    2006-01-01

    In radiotherapy it is recommended the use of an independent procedure of checking dose calculations, in order to verify the main treatment planning system and double check every patient dosimetry. In this work we present and automatic spreadsheet that import data from planning system using IMPAC/RTP format and verify monitor unit calculation using an independent calculus algorithm. Additionally, it perform a personalized analysis of dose volume histograms and several radiobiological parameters like TCP and NTCP. Finally, the application automatically generate a clinical dosimetry report for every patient, including treatment fields, fractionation, independent check results, dose volume analysis, and first day forms. (Author)

  4. Take the Reins on Model Quality with ModelCHECK and Gatekeeper

    Science.gov (United States)

    Jones, Corey

    2012-01-01

    Model quality and consistency has been an issue for us due to the diverse experience level and imaginative modeling techniques of our users. Fortunately, setting up ModelCHECK and Gatekeeper to enforce our best practices has helped greatly, but it wasn't easy. There were many challenges associated with setting up ModelCHECK and Gatekeeper including: limited documentation, restrictions within ModelCHECK, and resistance from end users. However, we consider ours a success story. In this presentation we will describe how we overcame these obstacles and present some of the details of how we configured them to work for us.

  5. 77 FR 38714 - Proposed Collection; Comment Request for the TE/GE Compliance Check Questionnaires

    Science.gov (United States)

    2012-06-28

    ... TE/GE Compliance Check Questionnaires AGENCY: Internal Revenue Service (IRS), Treasury. ACTION..., the IRS is soliciting comments concerning the TE/GE Compliance Check Questionnaires. DATES: Written... [email protected] . SUPPLEMENTARY INFORMATION: Title: TE/GE Compliance Check Questionnaires. OMB...

  6. [Airport security check of medical substances used during patient repatriation].

    Science.gov (United States)

    Felkai, Péter

    2012-09-16

    During airport security check of passenger luggage, hazardous items and substances are prohibited to be taken into the restricted safety zone of the airport and the aircraft. Among equipment of the medical staff escorting the patient, there are several devices and materials which are considered hazardous for security reasons. However, medical equipment and substances are indispensable for treating patients during the flight. The aim of the author was to present his experience obtained with the use of an instrument developed for testing liquids, aerosols and gels for security reasons. An instrument based on Raman spectroscopy was used for the identification of medical substances. The results confirmed that the instrument was able to recognize the tested medical substances. The non-destructive testing maintained sample integrity and asepsis. The data indicate that the instrument has a promising utility for the identification of medical substances. It seems important that during repatriation medical substances should be selected not only on the ground of their medical necessity, but their packaging should be also taken into consideration. It is necessary to perform more tests on different medical substances used in emergency care in order to make the database of medical substances stored in the library of instrument more complete.

  7. Evidence for the safety assurance of the radiation associated equipments for stat-up check

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Igarashi, Hiroshi; Saito, Kyoko; Kawaharada, Yasuhiro; Hirano, Kunihiro; Murase, Kenya; Mochizuki, Teruhito

    2008-01-01

    Based on the new amendment of the Medical Service Law and the Pharmaceutical Affairs Law, the safety control for the medical equipments and devices was strengthened; and a radiological technologist should be stipulated as a safety control manager for the medical equipments and devices. Although it is thought that Start-up check is important for the safety assurance, the enforcement situation is not clear until now. In this report, on the occasion of the start-up of the new Law, questionnaire about the start up check (time and a check items) were investigated from 56 hospitals applying the visit interview. Modality by modality check up time was obtained from 261 institutions by the descriptive study paper type. Start-up check and arming up were applied for almost all modalities about 30 minutes before start of the clinical tests. The check up items for the medical equipments and devices depended on each hospital. Therefore, safety assurance should be established, cooperating with the medical equipment distributors, the hospital sharing the checked results for the patients' safety. (author)

  8. The influence of social anxiety on the body checking behaviors of female college students.

    Science.gov (United States)

    White, Emily K; Warren, Cortney S

    2014-09-01

    Social anxiety and eating pathology frequently co-occur. However, there is limited research examining the relationship between anxiety and body checking, aside from one study in which social physique anxiety partially mediated the relationship between body checking cognitions and body checking behavior (Haase, Mountford, & Waller, 2007). In an independent sample of 567 college women, we tested the fit of Haase and colleagues' foundational model but did not find evidence of mediation. Thus we tested the fit of an expanded path model that included eating pathology and clinical impairment. In the best-fitting path model (CFI=.991; RMSEA=.083) eating pathology and social physique anxiety positively predicted body checking, and body checking positively predicted clinical impairment. Therefore, women who endorse social physique anxiety may be more likely to engage in body checking behaviors and experience impaired psychosocial functioning. Published by Elsevier Ltd.

  9. Diversity and ambivalence in general practitioners' attitudes towards preventive health checks - a qualitative study

    DEFF Research Database (Denmark)

    Søndergaard, Anne; Christensen, Bo; Maindal, Helle Terkildsen

    2012-01-01

    .The purpose of our study is to describe GPs' attitudes towards and concerns about providing preventive health checks and to describe their experiences with the health checks that they provide in daily practice. METHODS: A qualitative descriptive study was conducted based on three semi-structured focus group...... practice. CONCLUSIONS: Our study revealed that health checks are performed differently. Their quality differs, and the GPs perform the health check based on their personal attitude towards this service and prevention in general. Our analysis suggests that the doctors are basically uncertain about the best...... that there was great diversity in the content. The GPs were somewhat ambivalent towards health checks. Many GPs found the service beneficial for the patients. Concurrently, they had reservations about promoting ill-health, they questioned whether the health checks were a core mission of primary care, and they were...

  10. Perencanaan Check Dam Sungai Glugu Kabupaten Grobogan, Jawa Tengah

    OpenAIRE

    Kusuma, Abhibawa Tegar; Wijayanti, Deny; Atmojo, Pranoto Sapto; Edhisono, Sutarto

    2015-01-01

    Glugu River is a tributary of the Lusi River under the authority of the Central River Region Pemali - Juana, precisely located in the administrative area of the Grobogan Regency. Location of Glugu River located upstream, gave effect to the degradation of the river channel, so as to stabilize the river flow necessary to design coservation structure on Glugu River, that is check dam.The data used for design check dam are the primary data (geotechnical, geometry Glugu River, and water when the f...

  11. Mitigating check valve slamming and subsequentwater hammer events for PPFS using MOC

    International Nuclear Information System (INIS)

    Tian Wenxi; Su Guanghui; Wang Gaopeng; Qiu Suizheng; Xiao Zejun

    2009-01-01

    The method of characteristic (MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System (PPFS) during the alternate startup process. The motion of check valve disc was simulated using inertial valve model. Transient parameters including the pressure oscillation, local flow velocity and slamming of the check valve disc etc. have been obtained. The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps. The induced maximum pressure vibration amplitude is up to 5.0 MPa. The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer. It has been numerically approved to be an effective approach. (authors)

  12. Mitigating check valve slamming and subsequentwater hammer events for PPFS using MOC

    Institute of Scientific and Technical Information of China (English)

    TIAN Wenxi; SU Guanghui; WANG Gaopeng; QIU Suizheng; XIAO Zejun

    2009-01-01

    The method of characteristic (MOC) was adopted to analyze the check valve-induced water hammer behaviors for a Parallel Pumps Feedwater System (PPFS) during the alternate startup process. The motion of check valve disc was simulated using inertial valve model. Transient parameters including the pressure oscillation, local flow velocity and slamming of the check valve disc etc. have been obtained. The results showed that severe slamming between the valve disc and valve seat occurred during the alternate startup of parallel pumps. The induced maximum pressure vibration amplitude is up to 5.0 MPa. The scheme of appending a damping torque to slow down the check valve closing speed was also performed to mitigate of water hammer. It has been numerically approved to be an effective approach.

  13. The development of fusion sensor techniques for condition monitoring of a check valve

    International Nuclear Information System (INIS)

    Seong, S.H.; Kim, J.S.; Hur, S.; Kim, J.T.; Park, W.M.; Cha, D.B.

    2004-01-01

    The failures of check valves are one of the most important problems in nuclear power plants because the reverse flows through the failed check valve impact on the healthy hydraulic loop. The present test method of finding out the mechanical failure of a check valve is very risky in the radiated environments during normal operation. In addition, the detection of failures in the overhaul period is very costly and tedious because many check valves are used in the plants and manual disassembly work is required. We have suggested the fusion sensor technology for detecting the failures of check valves through measuring and analyzing the backward leakage flow and mechanical vibration without disassembling the check valve. The fusion sensor means that more than two sensors are used in order to identify and analyze the changes of the frequency response between the failed check valve and healthy check valve. We use the accelerometer and acoustic emission sensor as an alternative to the fusion sensor methodology. We have found that the acoustic emission sensor would be capable of directly detecting a high frequency acoustic wave generated from backward leakage flow itself at a low pressure and temperature. The accelerometer for detecting the mechanical vibration induced from leakage flows would, also, be useful at a high pressure and temperature from the previous studies. The effectiveness of this system is that it is possible for predictive maintenance and information of the problem valve will be captured and it reduces the radiation exposure for the maintenance personnel during power operation as well as the maintenance period. (orig.)

  14. Role of recent research in improving check valve reliability at nuclear power plants

    International Nuclear Information System (INIS)

    Kalsi, M.S.; Horst, C.L.; Wang, J.K.; Sharma, V.

    1990-01-01

    Check valve failures at nuclear power plants in recent years have led to serious safety concerns, and caused extensive damage to other plant components which had a significant impact on plant availability. In order to understand the failure mechanism and improve the reliability of check valves, a systematic research effort was proposed by Kalsi Engineering, Inc. to U.S. Nuclear Regulatory Commission (NRC). The overall goal of the research was to develop models for predicting the performance and degradation of swing check valves in nuclear power plant systems so that appropriate preventive maintenance or design modifications can be performed to improve the reliability of check valves. Under Phase I of this research, a large matrix of tests was run with instrumented swing check valves to determine the stability of the disc under a variety of upstream flow disturbances, covering a wide range of disc stop positions and flow velocities in two different valve sizes. The goals of Phase II research were to develop predictive models which quantify the anticipated degradation of swing check valves that have flow disturbances closely upstream of the valve and are operating under flow velocities that do not result in full disc opening. This research allows the inspection/maintenance activities to be focussed on those check valves that are more likely to suffer premature degradation. The quantitative wear and fatigue prediction methodology can be used to develop a sound preventive maintenance program. The results of the research also show the improvements in check valve performance/reliability that can be achieved by certain modifications in the valve design

  15. Safe Anesthesia For Every Tot

    DEFF Research Database (Denmark)

    Weiss, Markus; Vutskits, Laszlo; Hansen, Tom G

    2015-01-01

    PURPOSE OF REVIEW: The term 'safe use of anesthesia in children is ill-defined and requires definition of and focus on the 'safe conduct of pediatric anesthesia'. RECENT FINDINGS: The Safe Anesthesia For Every Tot initiative (www.safetots.org) has been set up during the last year to focus...... on the safe conduct of pediatric anesthesia. This initiative aims to provide guidance on markers of quality anesthesia care. The introduction and implementation of national regulations of 'who, where, when and how' are required and will result in an improved perioperative outcome in vulnerable children....... The improvement of teaching, training, education and supervision of the safe conduct of pediatric anesthesia are the main goals of the safetots.org initiative. SUMMARY: This initiative addresses the well known perioperative risks in young children, perioperative causes for cerebral morbidity as well as gaps...

  16. High performance ground penetrating radar survey of TA-49/Area 2. Final report

    International Nuclear Information System (INIS)

    Hoeberling, R.F.; Rangel, M.J. III

    1994-09-01

    The results of high performance ground penetrating radar study of Area 2 at Technical Area 49 are presented. The survey was commissioned as part of Los Alamos Laboratory's continuing Environmental Remediation program and was completed and analyzed before borehole studies in Area 2 were started. Based upon the ground penetrating radar results, the location of one of the planned boreholes was moved to assure the drilling area was as safe as possible. While earlier attempts to use commercial radar devices at this facility had not been successful, the radar and digital processing system developed at Los Alamos were able to significantly improve the buried physical detail of the site

  17. Assembly-line health check up in digitalized hospital.

    Science.gov (United States)

    Liu, Yalan; Yao, Bin; Zhang, Zigang

    2002-01-01

    The health check up flow of digital hospital can be consulted with the assembly line of industry factory. Because they have the following same features: highly specialized workstation, closeness and continuance, rhythm, balanced production, continuous production. The essential prerequisites are as the follows: The inspecting items and methods should be stable; advanced product mix and stable production design; standardized raw material, consumption, procedure, inspection method; there are lots of request for health inspection; the customers move at the least unit; the space arrangement should be reasonable; the time arrangement should be proportion. With the computer net, the digital inspection can achieves the raw material controlling accurately. The basis of check up line concerns about equipment, net and software, data collection, and personnel. The group technology is used in the health inspection flow design of the digital hospital in the field of items customers and zone redivided. The digital assembly linemic health inspect has the following stages: member registering, notice, check in, arrange order, time control, report, feedback and analysis. The assembly linemic has following advantages: increasing the productivity, the space utility, satisfaction of customer, fund returning, lowering the cost and ensuring the quality.

  18. The method of a joint intraday security check system based on cloud computing

    Science.gov (United States)

    Dong, Wei; Feng, Changyou; Zhou, Caiqi; Cai, Zhi; Dan, Xu; Dai, Sai; Zhang, Chuancheng

    2017-01-01

    The intraday security check is the core application in the dispatching control system. The existing security check calculation only uses the dispatch center’s local model and data as the functional margin. This paper introduces the design of all-grid intraday joint security check system based on cloud computing and its implementation. To reduce the effect of subarea bad data on the all-grid security check, a new power flow algorithm basing on comparison and adjustment with inter-provincial tie-line plan is presented. And the numerical example illustrated the effectiveness and feasibility of the proposed method.

  19. 47 CFR 1.1165 - Payment by cashier's check for regulatory fees.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Payment by cashier's check for regulatory fees. 1.1165 Section 1.1165 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL PRACTICE AND... regulatory fees. Payment by cashier's check may be required when a person or organization makes payment, on...

  20. Using Canonical Forms for Isomorphism Reduction in Graph-based Model Checking

    NARCIS (Netherlands)

    Kant, Gijs

    Graph isomorphism checking can be used in graph-based model checking to achieve symmetry reduction. Instead of one-to-one comparing the graph representations of states, canonical forms of state graphs can be computed. These canonical forms can be used to store and compare states. However, computing

  1. 78 FR 63565 - Proposed Collection; Comment Request for the TE/GE Compliance Check Questionnaires

    Science.gov (United States)

    2013-10-24

    ... TE/GE Compliance Check Questionnaires AGENCY: Internal Revenue Service (IRS), Treasury. ACTION..., the IRS is soliciting comments concerning the TE/GE Compliance Check Questionnaires. DATES: Written... . SUPPLEMENTARY INFORMATION: Title: TE/GE Compliance Check Questionnaires. OMB Number: 1545-2071. Form Number: Not...

  2. SU-D-BRD-04: The Impact of Automatic Radiation Therapy Plan Checks in Treatment Planning

    International Nuclear Information System (INIS)

    Gopan, O; Yang, F; Ford, E

    2015-01-01

    Purpose: The physics plan check verifies various aspects of a treatment plan after dosimetrists have finished creating the plan. Some errors in the plan which are caught by the physics check could be caught earlier in the departmental workflow. The purpose of this project was to evaluate a plan checking script that can be run within the treatment planning system (TPS) by the dosimetrists prior to plan approval and export to the record and verify system. Methods: A script was created in the Pinnacle TPS to automatically check 15 aspects of a plan for clinical practice conformity. The script outputs a list of checks which the plan has passed and a list of checks which the plan has failed so that appropriate adjustments can be made. For this study, the script was run on a total of 108 plans: IMRT (46/108), VMAT (35/108) and SBRT (27/108). Results: Of the plans checked by the script, 77/108 (71%) failed at least one of the fifteen checks. IMRT plans resulted in more failed checks (91%) than VMAT (51%) or SBRT (63%), due to the high failure rate of an IMRT-specific check, which checks that no IMRT segment < 5 MU. The dose grid size and couch removal checks caught errors in 10% and 14% of all plans – errors that ultimately may have resulted in harm to the patient. Conclusion: Approximately three-fourths of the plans being examined contain errors that could be caught by dosimetrists running an automated script embedded in the TPS. The results of this study will improve the departmental workflow by cutting down on the number of plans that, due to these types of errors, necessitate re-planning and re-approval of plans, increase dosimetrist and physician workload and, in urgent cases, inconvenience patients by causing treatment delays

  3. Participation in preventive health check-ups among 19,351 women in Germany

    Directory of Open Access Journals (Sweden)

    Stefanie Schülein

    2017-06-01

    Full Text Available In Germany, a biennial preventive health check-up has been available for individuals aged 35 and older since 1989. The check-up includes identification of cardiovascular disease risk factors and examinations for diabetes mellitus type 2 and kidney disease. Participation in preventive health check-ups among 19,351 women aged 35 to 74 in Germany in 2004 was investigated. Logistic regression was performed to examine associations between participation and age, marital status, education, socio-economic status (SES and region of residence. In total, 53.4% of women attended at least every two years, 23.4% attended irregularly and 23.2% never attended. In adjusted models, single, divorced, separated or widowed women were less likely to have a preventive health check-up at least every two years compared to married women (OR 0.63, 95% CI 0.57–0.71, while women in eastern Germany were less likely to participate (OR 0.80, 95% CI 0.75–0.86 than women in western Germany. Education showed no association with having a preventive health check-up at least every two years; however, women with low SES were less likely to participate compared to those with high SES (OR 0.82, 95% CI 0.74–0.92. About half of eligible women reported participating in health check-ups at least every two years, with participation varying according to socio-demographic characteristics. Women who are less likely to participate may benefit from receiving invitation letters within the framework of an organised programme. The benefits of general health checks, however, need to be evaluated.

  4. Evaluation of MODIS Land Surface Temperature with In Situ Snow Surface Temperature from CREST-SAFE

    Science.gov (United States)

    Perez Diaz, C. L.; Lakhankar, T.; Romanov, P.; Munoz, J.; Khanbilvardi, R.; Yu, Y.

    2016-12-01

    This paper presents the procedure and results of a temperature-based validation approach for the Moderate Resolution Imaging Spectroradiometer (MODIS) Land Surface Temperature (LST) product provided by the National Aeronautics and Space Administration (NASA) Terra and Aqua Earth Observing System satellites using in situ LST observations recorded at the Cooperative Remote Sensing Science and Technology Center - Snow Analysis and Field Experiment (CREST-SAFE) during the years of 2013 (January-April) and 2014 (February-April). A total of 314 day and night clear-sky thermal images, acquired by the Terra and Aqua satellites, were processed and compared to ground-truth data from CREST-SAFE with a frequency of one measurement every 3 min. Additionally, this investigation incorporated supplementary analyses using meteorological CREST-SAFE in situ variables (i.e. wind speed, cloud cover, incoming solar radiation) to study their effects on in situ snow surface temperature (T-skin) and T-air. Furthermore, a single pixel (1km2) and several spatially averaged pixels were used for satellite LST validation by increasing the MODIS window size to 5x5, 9x9, and 25x25 windows for comparison. Several trends in the MODIS LST data were observed, including the underestimation of daytime values and nighttime values. Results indicate that, although all the data sets (Terra and Aqua, diurnal and nocturnal) showed high correlation with ground measurements, day values yielded slightly higher accuracy ( 1°C), both suggesting that MODIS LST retrievals are reliable for similar land cover classes and atmospheric conditions. Results from the CREST-SAFE in situ variables' analyses indicate that T-air is commonly higher than T-skin, and that a lack of cloud cover results in: lower T-skin and higher T-air minus T-skin difference (T-diff). Additionally, the study revealed that T-diff is inversely proportional to cloud cover, wind speed, and incoming solar radiation. Increasing the MODIS window size

  5. Notification: Purchase Card and Convenience Check Audit

    Science.gov (United States)

    Project #OA-FY13-0116, April 11, 2013. The U.S. Environmental Protection Agency, Office of Inspector General, is beginning the fieldwork phase of its audit of the agency’s purchase card and convenience check programs.

  6. The Design of E-Traveler’s Check with Efficiency and Mutual Authentication

    OpenAIRE

    Chin-Chen Chang; Shih-Chang Chang

    2010-01-01

    Nowadays, traveling has become a popular leisure activity in our daily lives. Travelers can either use cash or credit cards to pay their bills. However, there is risk of cash being robbed or credit cards being copied. The traveler’s check, which is a third choice, comes in to get travelers around such risks and to protect their rights. Nevertheless, traditional travelers’ checks cannot keep imposters from forging and cashing them illegally. Hence, we propose a new type of check, called the e-...

  7. General health checks in adults for reducing morbidity and mortality from disease

    DEFF Research Database (Denmark)

    Krogsbøll, Lasse T; Jørgensen, Karsten Juhl; Grønhøj Larsen, Christian

    2012-01-01

    General health checks are common elements of health care in some countries. These aim to detect disease and risk factors for disease with the purpose of reducing morbidity and mortality. Most of the commonly used screening tests offered in general health checks have been incompletely studied. Als......, screening leads to increased use of diagnostic and therapeutic interventions, which can be harmful as well as beneficial. It is, therefore, important to assess whether general health checks do more good than harm....

  8. The laser calibration system for the STACEE ground-based gamma ray detector

    CERN Document Server

    Hanna, D

    2002-01-01

    We describe the design and performance of the laser system used for calibration monitoring of components of the STACEE detector. STACEE is a ground based gamma ray detector which uses the heliostats of a solar power facility to collect and focus Cherenkov light onto a system of secondary optics and photomultiplier tubes. To monitor the gain and check the linearity and timing properties of the phototubes and associated electronics, a system based on a dye laser, neutral density filters and optical fibres has been developed. In this paper we describe the system and present some results from initial tests made with it.

  9. Predicted buffer zones to protect temporary pond invertebrates from ground-based insecticide applications against desert locusts.

    NARCIS (Netherlands)

    Lahr, J.; Gadji, B.; Dia, D.

    2000-01-01

    To estimate safe downwind distances (i.e. buffer zone widths) for temporary ponds from ULV-treatments with current locust insecticides, experimental trials with two ground-based sprayers, the hand-held Micro-Ulva® and the vehicle-mounted Ulva-Mast® X15 Mark I, were conducted with fenitrothion

  10. The safe home project.

    Science.gov (United States)

    Arphorn, Sara; Jiraniratisai, Sopaphan; Rungtakul, Rungsri; Phutta, Nikom

    2011-12-01

    The Thai Health Promotion Foundation supported the Improvement of Quality of Life of Informal Workers project in Ban Luang District, Amphur Photaram, Ratchaburi Province. There were many informal workers in Ban Luang District. Sweet-crispy fish producers in Ban Luang were the largest group among the sweet-crispy fish producers in Thailand. This project was aimed at improving living and working conditions of informal workers, with a focus on the sweet-crispy fish group. Good practices of improved living and working conditions were used to help informal workers build safe, healthy and productive work environments. These informal workers often worked in substandard conditions and were exposed to various hazards in the working area. These hazards included risk of exposure to hot work environment, ergonomics-related injuries, chemical hazards, electrical hazards etc. Ergonomics problems were commonly in the sweet-crispy fish group. Unnatural postures such as prolonged sitting were performed dominantly. One hundred and fifty informal workers participated in this project. Occupational health volunteers were selected to encourage occupational health and safety in four groups of informal workers in 2009. The occupational health volunteers trained in 2008 were farmers, beauty salon workers and doll makers. The occupational health and safety knowledge is extended to a new informal worker group: sweet-crispy fish producer, in 2009. The occupational health and safety training for sweet-crispy fish group is conducted by occupational health volunteers. The occupational health volunteers increased their skills and knowledge assist in to make safe home and safe community through participatory oriented training. The improvement of living and working condition is conducted by using a modified WISH, Work Improvement for Safe Home, checklist. The plans of improvement were recorded. The informal workers showed improvement mostly on material handling and storage. The safe uses and safe

  11. Two‐year experience with the commercial Gamma Knife Check software

    Science.gov (United States)

    Bhatnagar, Jagdish; Bednarz, Greg; Novotny, Josef; Flickinger, John; Lunsford, L. Dade; Huq, M. Saiful

    2016-01-01

    The Gamma Knife Check software is an FDA approved second check system for dose calculations in Gamma Knife radiosurgery. The purpose of this study was to evaluate the accuracy and the stability of the commercial software package as a tool for independent dose verification. The Gamma Knife Check software version 8.4 was commissioned for a Leksell Gamma Knife Perfexion and a 4C unit at the University of Pittsburgh Medical Center in May 2012. Independent dose verifications were performed using this software for 319 radiosurgery cases on the Perfexion and 283 radiosurgery cases on the 4C units. The cases on each machine were divided into groups according to their diagnoses, and an averaged absolute percent dose difference for each group was calculated. The percentage dose difference for each treatment target was obtained as the relative difference between the Gamma Knife Check dose and the dose from the tissue maximum ratio algorithm (TMR 10) from the GammaPlan software version 10 at the reference point. For treatment plans with imaging skull definition, results obtained from the Gamma Knife Check software using the measurement‐based skull definition method are used for comparison. The collected dose difference data were also analyzed in terms of the distance from the treatment target to the skull, the number of treatment shots used for the target, and the gamma angles of the treatment shots. The averaged percent dose differences between the Gamma Knife Check software and the GammaPlan treatment planning system are 0.3%, 0.89%, 1.24%, 1.09%, 0.83%, 0.55%, 0.33%, and 1.49% for the trigeminal neuralgia, acoustic neuroma, arteriovenous malformation (AVM), meningioma, pituitary adenoma, glioma, functional disorders, and metastasis cases on the Perfexion unit. The corresponding averaged percent dose differences for the 4C unit are 0.33%, 1.2%, 2.78% 1.99%, 1.4%, 1.92%, 0.62%, and 1.51%, respectively. The dose difference is, in general, larger for treatment targets in the

  12. checkCIF/PLATON report Datablock: shelx

    Indian Academy of Sciences (India)

    7 ALERT level G = General information/check it is not something unexpected. 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 3 ALERT type 2 Indicator that the structure ... However, the purpose of your study may justify the reported deviations and the more serious of these should normally be ...

  13. checkCIF/PLATON report Datablock: 1

    Indian Academy of Sciences (India)

    6 ALERT level G = General information/check it is not something unexpected. 2 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 8 ALERT type 2 Indicator that the structure ... However, the purpose of your study may justify the reported deviations and the more serious of these should normally be ...

  14. checkCIF/PLATON report Datablock: 3

    Indian Academy of Sciences (India)

    5 ALERT level G = General information/check it is not something unexpected. 5 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 15 ALERT type 2 Indicator that the structure ... However, the purpose of your study may justify the reported deviations and the more serious of these should normally be ...

  15. checkCIF/PLATON report Datablock: 3

    Indian Academy of Sciences (India)

    5 ALERT level G = General information/check it is not something unexpected. 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 3 ALERT type 2 Indicator that the structure ... However, the purpose of your study may justify the reported deviations and the more serious of these should normally be ...

  16. checkCIF/PLATON report Datablock: shelxl

    Indian Academy of Sciences (India)

    6 ALERT level G = General information/check it is not something unexpected. 0 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 4 ALERT type 2 Indicator that the structure ... However, the purpose of your study may justify the reported deviations and the more serious of these should normally be ...

  17. Separation of Powers: Checks and Balances.

    Science.gov (United States)

    Taylor, Bonnie

    1988-01-01

    This article offers a class activity on separation of powers and checks and balances within the U.S. government. Based on Franklin Delano Roosevelt's attempt to push through legislation for the New Deal of the 1930s by "packing" the U.S. Supreme Court, the activity includes worksheets and teaching suggestions. (JDH)

  18. Effect of faulting on ground-water movement in the Death Valley region, Nevada and California

    International Nuclear Information System (INIS)

    Faunt, C.C.

    1997-01-01

    This study characterizes the hydrogeologic system of the Death Valley region, an area covering approximately 100,000 square kilometers. The study also characterizes the effects of faults on ground-water movement in the Death Valley region by synthesizing crustal stress, fracture mechanics,a nd structural geologic data. The geologic conditions are typical of the Basin and Range Province; a variety of sedimentary and igneous intrusive and extrusive rocks have been subjected to both compressional and extensional deformation. Faulting and associated fracturing is pervasive and greatly affects ground-water flow patterns. Faults may become preferred conduits or barriers to flow depending on whether they are in relative tension, compression, or shear and other factors such as the degree of dislocations of geologic units caused by faulting, the rock types involved, the fault zone materials, and the depth below the surface. The current crustal stress field was combined with fault orientations to predict potential effects of faults on the regional ground-water flow regime. Numerous examples of fault-controlled ground-water flow exist within the study area. Hydrologic data provided an independent method for checking some of the assumptions concerning preferential flow paths. 97 refs., 20 figs., 5 tabs

  19. SU-F-T-96: A New Paradigm of Weekly Chart Checking for Radiation Therapy Clinics

    International Nuclear Information System (INIS)

    Tan, J; Pompos, A; Jiang, S; Yan, Y

    2016-01-01

    Purpose: To put forth an innovative clinical paradigm for weekly chart checking so that treatment status is periodically checked accurately and efficiently. This study also aims to help optimize the chart checking clinical workflow in a busy radiation therapy clinic. Methods: It is mandated by the Texas Administrative code to check patient charts of radiation therapy once a week or every five fractions, however it varies drastically among institutions in terms of when and how it is done. Some do it every day, but a lot of efforts are wasted on opening ineligible charts; some do it on a fixed day but the distribution of intervals between subsequent checks is not optimal. To establish an optimal chart checking procedure, a new paradigm was developed to achieve 1) charts are checked more accurately and more efficiently; 2) charts are checked on optimal days without any miss; 3) workload is evened out throughout a week when multiple physicists are involved. All active charts will be accessed by querying the R&V system. Priority is assigned to each chart based on the number of days before the next due date followed by sorting and workload distribution steps. New charts are also taken into account when distributing the workload so it is reasonably even throughout the week. Results: Our clinical workflow became more streamlined and smooth. In addition, charts get checked in a more timely fashion so that errors would get caught earlier should they occur. Conclusion: We developed a new weekly chart checking diagram. It helps physicists check charts in a timely manner, saves their time in busy clinics, and consequently reduces possible errors.

  20. SU-F-T-96: A New Paradigm of Weekly Chart Checking for Radiation Therapy Clinics

    Energy Technology Data Exchange (ETDEWEB)

    Tan, J; Pompos, A; Jiang, S; Yan, Y [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To put forth an innovative clinical paradigm for weekly chart checking so that treatment status is periodically checked accurately and efficiently. This study also aims to help optimize the chart checking clinical workflow in a busy radiation therapy clinic. Methods: It is mandated by the Texas Administrative code to check patient charts of radiation therapy once a week or every five fractions, however it varies drastically among institutions in terms of when and how it is done. Some do it every day, but a lot of efforts are wasted on opening ineligible charts; some do it on a fixed day but the distribution of intervals between subsequent checks is not optimal. To establish an optimal chart checking procedure, a new paradigm was developed to achieve 1) charts are checked more accurately and more efficiently; 2) charts are checked on optimal days without any miss; 3) workload is evened out throughout a week when multiple physicists are involved. All active charts will be accessed by querying the R&V system. Priority is assigned to each chart based on the number of days before the next due date followed by sorting and workload distribution steps. New charts are also taken into account when distributing the workload so it is reasonably even throughout the week. Results: Our clinical workflow became more streamlined and smooth. In addition, charts get checked in a more timely fashion so that errors would get caught earlier should they occur. Conclusion: We developed a new weekly chart checking diagram. It helps physicists check charts in a timely manner, saves their time in busy clinics, and consequently reduces possible errors.

  1. 28 CFR 105.23 - Procedure for requesting criminal history record check.

    Science.gov (United States)

    2010-07-01

    ... record checks solely for the purpose of screening its private security officers; and that it will abide... employee to submit those prints for a state and national criminal history record check. An authorized... specified by the SIB. (c) Upon receipt of an employee's fingerprints, the SIB shall perform a fingerprint...

  2. Barriers to Implementation of Recommendations for Transport of Children in Ground Ambulances.

    Science.gov (United States)

    Woods, Rashida H; Shah, Manish; Doughty, Cara; Gilchrest, Anthony

    2017-10-16

    The National Highway Traffic Safety Administration (NHTSA) released draft recommendations in 2010 on the safe transport of children in ground ambulances. The purpose of this study was to assess awareness of these guidelines among emergency medical service (EMS) agencies and to identify implementation barriers. We conducted a cross-sectional, anonymous online survey of 911-responding, ground transport EMS agencies in Texas. Demographics, modes of transport based on case scenarios, and barriers to implementation were assessed. Of 62 eligible EMS agencies that took the survey, 35.7% were aware of the NHTSA guidelines, 62.5% agreed they would improve safety, and 41.1% planned to implement them. Seventy-five percent of EMS agencies used the ideal or acceptable alternative to transport children requiring continuous monitoring, and 69.5% chose ideal or acceptable alternatives for children requiring spinal immobilization. The ideal or acceptable alternative was not chosen for children who were not injured or ill (93.2%), ill or injured but not requiring continuous monitoring (53.3%), and situations when multiple patients required transport (57.6%). The main requirements for implementation were provider education, ambulance interior modifications, new guidelines in the EMS agency, and purchase of new equipment. Few EMS agencies are aware of the NHTSA guidelines on safe transport of children in ground ambulances. Although most agencies appropriately transport children who require monitoring, interventions, or spinal immobilization, they use inappropriate means to transport children in situations with multiple patients, lack of injury or illness, or lack of need for monitoring.

  3. Body checking and eating cognitions in Brazilian outpatients with eating disorders and non psychiatric controls.

    Science.gov (United States)

    Kachani, Adriana Trejger; Barroso, Lucia Pereira; Brasiliano, Silvia; Cordás, Táki Athanássios; Hochgraf, Patrícia Brunfentrinker

    2015-12-01

    Compare inadequate eating behaviors and their relationship to body checking in three groups: patients with anorexia nervosa (AN), patients with bulimia nervosa (BN) and a control group (C). Eighty three outpatients with eating disorders (ED) and 40 controls completed eating attitudes and body checking questionnaires. The overall relationship between the eating attitude and body checking was statistically significant in all three groups. The worse the eating attitude, the greater the body checking behavior. However, when we look at each group individually, the relationship was only statistically significant in the AN group (r=.354, p=0.020). The lower the desired weight and the worse the eating attitude, the more people check themselves, although in the presence of an ED the relationship between body checking and food restrictions is greater. In patients displaying the AN subgroup, body checking is also related to continued dietary control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Error Checking for Chinese Query by Mining Web Log

    Directory of Open Access Journals (Sweden)

    Jianyong Duan

    2015-01-01

    Full Text Available For the search engine, error-input query is a common phenomenon. This paper uses web log as the training set for the query error checking. Through the n-gram language model that is trained by web log, the queries are analyzed and checked. Some features including query words and their number are introduced into the model. At the same time data smoothing algorithm is used to solve data sparseness problem. It will improve the overall accuracy of the n-gram model. The experimental results show that it is effective.

  5. FIXUP2007, ENDF Format Redundant Cross-Sections Check

    International Nuclear Information System (INIS)

    2007-01-01

    1 - Description of program or function: FIXUP is designed to read evaluated data in the ENDF/B format, perform corrections and output the results in the ENDF/B format. One of the most important functions of this code is to redefine all redundant cross sections to be exactly equal to the sum of its parts. IAEA1309/11: This version includes the updates up to January 30, 2007. Changes in ENDF/B-VII Format and procedures, as well as the evaluations themselves, make it impossible for versions of the ENDF/B pre-processing codes earlier than PREPRO 2007 (2007 Version) to accurately process current ENDF/B-VII evaluations. The present code can handle all existing ENDF/B-VI evaluations through release 8, which will be the last release of ENDF/B-VI. Modifications from previous versions: - Fixup VERS. 2007-1 (Jan. 2007): checked against all ENDF/B-VII; increased page size from 60,000 to 600,000 data points 2 - Method of solution: FIXUP: All MAT numbers on an ENDF/B tape are processed; each MAT is treated separately. Within each MAT, each section before and after MF=3 is read, checked/corrected and output. When MF=3 is located, all cross sections are read, sections deleted, created, checked/corrected (based on user input) and after several intermediate stages written to output. 3 - Restrictions on the complexity of the problem: The program uses only the ENDF/B BCD format tape and copy all sections except File 3 as read. It is assumed that the data is correctly coded. No error checking is performed. Since File 3 data are in identical format for ENDF/B versions I through VI, the program can be used with all these versions. - All data in file 3 and 23 must be linearly interpolable

  6. Space shuttle prototype check valve development

    Science.gov (United States)

    Tellier, G. F.

    1976-01-01

    Contaminant-resistant seal designs and a dynamically stable prototype check valve for the orbital maneuvering and reaction control helium pressurization systems of the space shuttle were developed. Polymer and carbide seal models were designed and tested. Perfluoroelastomers compatible with N2O4 and N2H4 types were evaluated and compared with Teflon in flat and captive seal models. Low load sealing and contamination resistance tests demonstrated cutter seal superiority over polymer seals. Ceramic and carbide materials were evaluated for N2O4 service using exposure to RFNA as a worst case screen; chemically vapor deposited tungsten carbide was shown to be impervious to the acid after 6 months immersion. A unique carbide shell poppet/cutter seat check valve was designed and tested to demonstrate low cracking pressure ( 2.0 psid), dynamic stability under all test bench flow conditions, contamination resistance (0.001 inch CRES wires cut with 1.5 pound seat load) and long life of 100,000 cycles (leakage 1.0 scc/hr helium from 0.1 to 400 psig).

  7. Classification and checking model of pedestrian crossing

    Directory of Open Access Journals (Sweden)

    Luis Delgado Méndez

    2012-11-01

    After realizing this investigation it can be confirmed that the functionality of a pedestrian crossing depends on almost a hundred parameters which must be checked or measured, in turn proving that this design and construction process is indeed complex.

  8. Decentralized Consistency Checking in Cross-organizational Workflows

    NARCIS (Netherlands)

    Wombacher, Andreas

    Service Oriented Architectures facilitate loosely coupled composed services, which are established in a decentralized way. One challenge for such composed services is to guarantee consistency, i.e., deadlock-freeness. This paper presents a decentralized approach to consistency checking, which

  9. Blood Pressure Matters: Keep Hypertension in Check

    Science.gov (United States)

    ... 2016 Print this issue Blood Pressure Matters Keep Hypertension in Check En español Send us your comments ... 1 in 3 adults in the U.S. has high blood pressure, but many don’t realize it. High blood ...

  10. Development and Testing of Techniques for In-Ground Stabilization, Size Reduction and Safe Removal of Radioactive Wastes Stored in Large Containments in Burial Grounds - 13591

    International Nuclear Information System (INIS)

    Halliwell, Stephen

    2013-01-01

    Radioactive waste materials, including Transuranic (TRU) wastes from laboratories have been stored below ground in large containments at a number of sites in the US DOE Complex, and at nuclear sites in Europe. These containments are generally referred to as caissons or shafts. The containments are in a range of sizes and depths below grade. The caissons at the DOE's Hanford site are cylindrical, of the order of 2,500 mm in diameter, 3,050 mm in height and are buried about 6,000 mm below grade. One type of caisson is made out of corrugated pipe, whereas others are made of concrete with standard re-bar. However, the larger shafts in the UK are of the order of 4,600 mm in diameter, 53,500 mm deep, and 12,000 below grade. This paper describes the R and D work and testing activities performed to date to evaluate the concept of in-ground size reduction and stabilization of the contents of large containments similar to those at Hanford. In practice, the height of the Test Facility provided for a test cell that was approximately 22' deep. That prevented a 'full scale mockup' test in the sense that the Hanford Caisson configuration would be an identical replication. Therefore, the project was conducted in two phases. The first phase tested a simulated Caisson with surrogate contents, and part of a Chute section, and the second phase tested a full chute section. These tests were performed at VJ Technologies Test Facility located in East Haven, CT, as part of the Proof of Design Concept program for studying the feasibility of an in-situ grout/grind/mix/stabilize technology for the remediation of four caissons at the 618-11 Burial Ground at US Department of Energy Hanford Site. The test site was constructed such that multiple testing areas were provided for the evaluation of various tools, equipment and procedures under conditions that simulated the Hanford site, with representative soils and layout dimensions. (authors)

  11. Development and Testing of Techniques for In-Ground Stabilization, Size Reduction and Safe Removal of Radioactive Wastes Stored in Large Containments in Burial Grounds - 13591

    Energy Technology Data Exchange (ETDEWEB)

    Halliwell, Stephen [VJ Technologies Inc, 89 Carlough Road, Bohemia, NY (United States)

    2013-07-01

    Radioactive waste materials, including Transuranic (TRU) wastes from laboratories have been stored below ground in large containments at a number of sites in the US DOE Complex, and at nuclear sites in Europe. These containments are generally referred to as caissons or shafts. The containments are in a range of sizes and depths below grade. The caissons at the DOE's Hanford site are cylindrical, of the order of 2,500 mm in diameter, 3,050 mm in height and are buried about 6,000 mm below grade. One type of caisson is made out of corrugated pipe, whereas others are made of concrete with standard re-bar. However, the larger shafts in the UK are of the order of 4,600 mm in diameter, 53,500 mm deep, and 12,000 below grade. This paper describes the R and D work and testing activities performed to date to evaluate the concept of in-ground size reduction and stabilization of the contents of large containments similar to those at Hanford. In practice, the height of the Test Facility provided for a test cell that was approximately 22' deep. That prevented a 'full scale mockup' test in the sense that the Hanford Caisson configuration would be an identical replication. Therefore, the project was conducted in two phases. The first phase tested a simulated Caisson with surrogate contents, and part of a Chute section, and the second phase tested a full chute section. These tests were performed at VJ Technologies Test Facility located in East Haven, CT, as part of the Proof of Design Concept program for studying the feasibility of an in-situ grout/grind/mix/stabilize technology for the remediation of four caissons at the 618-11 Burial Ground at US Department of Energy Hanford Site. The test site was constructed such that multiple testing areas were provided for the evaluation of various tools, equipment and procedures under conditions that simulated the Hanford site, with representative soils and layout dimensions. (authors)

  12. Selling a gun to a stranger without a background check: acceptable behaviour?

    Science.gov (United States)

    Hemenway, David; Azrael, Deborah; Miller, Matthew

    2017-06-24

    One way that guns get into the wrong hands is via gun sales without a background check. While the large majority of Americans support laws requiring universal background checks, no prior study has assessed whether Americans think it is acceptable behaviour to sell a gun to a stranger without a background check, whether or not there is a law against it. We sponsored a nationally representative survey of over 3900 American adults, oversampling gun owners, using an online panel provided by the survey firm Growth for Knowledge. Over 72% of American adults agree or strongly agree with the statement that 'whether it is legal or not, it is NOT acceptable to sell a gun to a stranger without a background check' and 11% disagree or strongly disagree. Subgroups less likely to agree are young adults, men, conservatives, those with less than a high school education and gun owners. Reducing the number of guns sold without a background check could help reduce the flow of guns to felons. Changes in normative attitudes and behaviours, as well as changes in law, could help accomplish this goal. Most Americans, including gun owners, believe selling a gun to a stranger without a background check is not acceptable behaviour. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. UMTRA Ground Water Project management action process document

    International Nuclear Information System (INIS)

    1996-03-01

    A critical U.S. Department of Energy (DOE) mission is to plan, implement, and complete DOE Environmental Restoration (ER) programs at facilities that were operated by or in support of the former Atomic Energy Commission (AEC). These facilities include the 24 inactive processing sites the Uranium Mill Tailings Radiation Control Act (UMTRCA) (42 USC Section 7901 et seq.) identified as Title I sites, which had operated from the late 1940s through the 1970s. In UMTRCA, Congress acknowledged the potentially harmful health effects associated with uranium mill tailings and directed the DOE to stabilize, dispose of, and control the tailings in a safe and environmentally sound manner. The UMTRA Surface Project deals with buildings, tailings, and contaminated soils at the processing sites and any associated vicinity properties (VP). Surface remediation at the processing sites will be completed in 1997 when the Naturita, Colorado, site is scheduled to be finished. The UMTRA Ground Water Project was authorized in an amendment to the UMTRCA (42 USC Section 7922(a)), when Congress directed DOE to comply with U.S. Environmental Protection Agency (EPA) ground water standards. The UMTRA Ground Water Project addresses any contamination derived from the milling operation that is determined to be present at levels above the EPA standards

  14. SAFE/SNAP application to shipboard security

    International Nuclear Information System (INIS)

    Grady, L.M.; Walker, J.L.; Polito, J.

    1981-11-01

    An application of the combined Safeguards Automated Facility Evaluation/Safeguards Network Analysis Procedure (SAFE/SNAP) modeling technique to a physical protection system (PPS) aboard a generic ship is described. This application was performed as an example of how the SAFE and SNAP techniques could be used. Estimates of probability of interruption and neutralization for the example shipboard PPS are provided by SAFE as well as an adversary scenario, which serves as input to SNAP. This adversary scenario is analyzed by SNAP through four cases which incorporate increasingly detailed security force tactics. Comparisons between the results of the SAFE and SNAP analyses are made and conclusions drawn on the validity of each technique. Feedback from SNAP to SAFE is described, and recommendations for upgrading the ship based on the results of the SAFE/SNAP application are also discussed

  15. Asymptomatic brain tumor detected at brain check-up

    International Nuclear Information System (INIS)

    Onizuka, Masanari; Suyama, Kazuhiko; Shibayama, Akira; Hiura, Tsuyoshi; Horie, Nobutaka; Miyazaki, Hisaya

    2001-01-01

    Brain check-up was performed in 4000 healthy subjects who underwent medical and radiological examinations for possible brain diseases in our hospital from April 1996 to March 2000. Magnetic resonance imaging revealed 11 brain tumors which consisted of six meningiomas, three pituitary adenomas, one astrocytoma, and one epidermoid cyst. The detection rate of incidental brain tumor in our hospital was 0.3%. Nine patients underwent surgery, with one case of morbidity due to postoperative transient oculomotor nerve paresis. The widespread use of brain check-up may increasingly detect asymptomatic brain tumors. Surgical indications for such lesions remain unclear, and the strategy for treatment should be determined with consideration of the patient's wishes. (author)

  16. Toward improved design of check dam systems: A case study in the Loess Plateau, China

    Science.gov (United States)

    Pal, Debasish; Galelli, Stefano; Tang, Honglei; Ran, Qihua

    2018-04-01

    Check dams are one of the most common strategies for controlling sediment transport in erosion prone areas, along with soil and water conservation measures. However, existing mathematical models that simulate sediment production and delivery are often unable to simulate how the storage capacity of check dams varies with time. To explicitly account for this process-and to support the design of check dam systems-we developed a modelling framework consisting of two components, namely (1) the spatially distributed Soil Erosion and Sediment Delivery Model (WaTEM/SEDEM), and (2) a network-based model of check dam storage dynamics. The two models are run sequentially, with the second model receiving the initial sediment input to check dams from WaTEM/SEDEM. The framework is first applied to Shejiagou catchment, a 4.26 km2 area located in the Loess Plateau, China, where we study the effect of the existing check dam system on sediment dynamics. Results show that the deployment of check dams altered significantly the sediment delivery ratio of the catchment. Furthermore, the network-based model reveals a large variability in the life expectancy of check dams and abrupt changes in their filling rates. The application of the framework to six alternative check dam deployment scenarios is then used to illustrate its usefulness for planning purposes, and to derive some insights on the effect of key decision variables, such as the number, size, and site location of check dams. Simulation results suggest that better performance-in terms of life expectancy and sediment delivery ratio-could have been achieved with an alternative deployment strategy.

  17. Efficient Semantics-Based Compliance Checking Using LTL Formulae and Unfolding

    Directory of Open Access Journals (Sweden)

    Liang Song

    2013-01-01

    Full Text Available Business process models are required to be in line with frequently changing regulations, policies, and environments. In the field of intelligent modeling, organisations concern automated business process compliance checking as the manual verification is a time-consuming and inefficient work. There exist two key issues for business process compliance checking. One is the definition of a business process retrieval language that can be employed to capture the compliance rules, the other concerns efficient evaluation of these rules. Traditional syntax-based retrieval approaches cannot deal with various important requirements of compliance checking in practice. Although a retrieval language that is based on semantics can overcome the drawback of syntax-based ones, it suffers from the well-known state space explosion. In this paper, we define a semantics-based process model query language through simplifying a property specification pattern system without affecting its expressiveness. We use this language to capture semantics-based compliance rules and constraints. We also propose a feasible approach in such a way that the compliance checking will not suffer from the state space explosion as much as possible. A tool is implemented to evaluate the efficiency. An experiment conducted on three model collections illustrates that our technology is very efficient.

  18. Experimental and analytical studies on waterhammer generated by the closing of check valves

    International Nuclear Information System (INIS)

    Huet, J.L.; Garcia, J.L.; Coppolani, P.; Ziegler, B.

    1987-01-01

    A double-guillotine rupture on a water line upstream from a check valve generates a severe transient between the check valve and the pressure vessel on the downstream side. Successively following phenomena occur: - decrease then reversal of the flow, - closing of the check valve with impact of the plug on its seat, - waterhammer propagating in the pipe downstream from the check valve. The COMMISARIAT A L'ENERGIE ATOMIQUE (C.E.A.) FRAMATOME and ELECTRICITE DE FRANCE (E.D.F.) have undertaken a joint program in order to: - investigate the behavior uf the check valve in the event of a sudden closure, - evaluate the pressure and flow transient in the line. The program includes: - full scale tests in two loops, CLAUDIA (C.E.A.) and ECLAIR (E.D.F.), - analytical studies in order to qualify the calculation codes. This paper describes the experimental program and presents the analysis results for a benchmark test

  19. Model Checking - Automated Verification of Computational Systems

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 14; Issue 7. Model Checking - Automated Verification of Computational Systems. Madhavan Mukund. General Article Volume 14 Issue 7 July 2009 pp 667-681. Fulltext. Click here to view fulltext PDF. Permanent link:

  20. Combining monitoring with run-time assertion checking

    NARCIS (Netherlands)

    Gouw, Stijn de

    2013-01-01

    We develop a new technique for Run-time Checking for two object-oriented languages: Java and the Abstract Behavioral Specification language ABS. In object-oriented languages, objects communicate by sending each other messages. Assuming encapsulation, the behavior of objects is completely

  1. Multi-Core Emptiness Checking of Timed Büchi Automata using Inclusion Abstraction

    DEFF Research Database (Denmark)

    Laarman, Alfons; Olesen, Mads Chr.; Dalsgaard, Andreas

    2013-01-01

    This paper contributes to the multi-core model checking of timed automata (TA) with respect to liveness properties, by investigating checking of TA Büchi emptiness under the very coarse inclusion abstraction or zone subsumption, an open problem in this field. We show that in general Büchi emptiness...... parallel LTL model checking algorithm for timed automata. The algorithms are implemented in LTSmin, and experimental evaluations show the effectiveness and scalability of both contributions: subsumption halves the number of states in the real-world FDDI case study, and the multi-core algorithm yields...

  2. The check sheet for diagnosis of postmortem CT. Development and the first impression

    International Nuclear Information System (INIS)

    Takahashi, Naoya; Higuchi, Takeshi; Shiotani, Motoi; Sato, Suguru; Maeda, Haruo; Hirose, Yasuo

    2010-01-01

    We developed the check sheet for diagnosis of postmortem CT. We listed the findings that had been reported as causes of death, postmortem changes, and changes caused by cardiopulmonary resuscitation on the sheet. We used the check sheet for 26 postmortem CT of cases with cardiopulmonary arrest on arrival. The causes of death were proposed in 11 cases. The check sheet was useful to diagnose postmortem CT. (author)

  3. checkCIF/PLATON report Datablock: 1

    Indian Academy of Sciences (India)

    (Positive) Residual Density 13.61 eA-3. PLAT201_ALERT_2_B Isotropic non-H Atoms in Main Residue(s) . ... Weight Differ by .. 4.99 Check. PLAT094_ALERT_2_C Ratio of Maximum / Minimum Residual Density . ... 9 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 20 ALERT type 2 Indicator that ...

  4. checkCIF/PLATON report Datablock: platon

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. Structure factors have been supplied for datablock(s) platon. No syntax errors found. CIF dictionary Interpreting this report. Datablock: platon. Bond precision: C-C = 0.0033 A. Wavelength=0.71073. Cell: a=16.345(7) b=6.288(3) c=19.938(8) alpha=90 beta=96.169(7) gamma=90. Temperature:.

  5. checkCIF/PLATON report Datablock: I

    Indian Academy of Sciences (India)

    The relevant atom site should be identified. STRVA01_ALERT_4_C. Flack test results are ambiguous. ... 7 ALERT type 3 Indicator that the structure quality may be low. 5 ALERT type 4 Improvement, methodology, query or ... paper, to upload your CIF via our web site. PLATON version of 20/08/2014; check.def file version of ...

  6. checkCIF/PLATON report Datablock: shelxl

    Indian Academy of Sciences (India)

    6 ALERT level G = General information/check it is not something unexpected. 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 15 ALERT type 2 Indicator that the structure model may be wrong or deficient. 9 ALERT type 3 Indicator that the structure quality may be low. 1 ALERT type 4 Improvement, ...

  7. Inspection of power and ground layers in PCB images

    Science.gov (United States)

    Bunyak, Filiz; Ercal, Fikret

    1998-10-01

    In this work, we present an inspection method for power and ground (P&G) layers of printed circuit boards (PCB) also called utility layers. Design considerations for the P&G layers are different than those of signal layers. Current PCB inspection approaches cannot be applied to these layers. P&G layers act as internal ground, neutral or power sources. P&G layers are predominantly copper with occasional pad areas (without copper) called clearance. Defect definition is based on the spacing between the holes that will be drilled in clearances and the surrounding copper. Overlap of pads of different sizes and shapes are allowed. This results in complex, hard to inspect clearances. Our inspection is based on identification of shape, size and position of the individual pads that contribute to an overlapping clearance and then inspection of each pad based on design rules and tolerances. Main steps of our algorithm are as follows: (1) extraction and preprocessing of clearance contours; (2) decomposition of contours into segments: corner detection and matching lines or circular arcs between two corners; (3) determination of the pads from partial contour information obtained in step (2), and (4) design rules checking for each detected pad.

  8. Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

    International Nuclear Information System (INIS)

    Chiara, P.; Morelli, A.

    2010-01-01

    The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

  9. Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

    Science.gov (United States)

    Chiara, P.; Morelli, A.

    2010-05-01

    The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements. Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken. This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

  10. TFTR grounding scheme and ground-monitor system

    International Nuclear Information System (INIS)

    Viola, M.

    1983-01-01

    The Tokamak Fusion Test Reactor (TFTR) grounding system utilizes a single-point ground. It is located directly under the machine, at the basement floor level, and is tied to the building perimeter ground. Wired to this single-point ground, via individual 500 MCM insulated cables, are: the vacuum vessel; four toroidal field coil cases/inner support structure quadrants; umbrella structure halves; the substructure ring girder; radial beams and columns; and the diagnostic systems. Prior to the first machine operation, a ground-loop removal program was initiated. It required insulation of all hangers and supports (within a 35-foot radius of the center of the machine) of the various piping, conduits, cable trays, and ventilation systems. A special ground-monitor system was designed and installed. It actively monitors each of the individual machine grounds to insure that there are no inadvertent ground loops within the machine structure or its ground and that the machine grounds are intact prior to each pulse. The TFTR grounding system has proven to be a very manageable system and one that is easy to maintain

  11. Energy reduction through voltage scaling and lightweight checking

    Science.gov (United States)

    Kadric, Edin

    As the semiconductor roadmap reaches smaller feature sizes and the end of Dennard Scaling, design goals change, and managing the power envelope often dominates delay minimization. Voltage scaling remains a powerful tool to reduce energy. We find that it results in about 60% geomean energy reduction on top of other common low-energy optimizations with 22nm CMOS technology. However, when voltage is reduced, it becomes easier for noise and particle strikes to upset a node, potentially causing Silent Data Corruption (SDC). The 60% energy reduction, therefore, comes with a significant drop in reliability. Duplication with checking and triple-modular redundancy are traditional approaches used to combat transient errors, but spending 2--3x the energy for redundant computation can diminish or reverse the benefits of voltage scaling. As an alternative, we explore the opportunity to use checking operations that are cheaper than the base computation they are guarding. We devise a classification system for applications and their lightweight checking characteristics. In particular, we identify and evaluate the effectiveness of lightweight checks in a broad set of common tasks in scientific computing and signal processing. We find that the lightweight checks cost only a fraction of the base computation (0-25%) and allow us to recover the reliability losses from voltage scaling. Overall, we show about 50% net energy reduction without compromising reliability compared to operation at the nominal voltage. We use FPGAs (Field-Programmable Gate Arrays) in our work, although the same ideas can be applied to different systems. On top of voltage scaling, we explore other common low-energy techniques for FPGAs: transmission gates, gate boosting, power gating, low-leakage (high-Vth) processes, and dual-V dd architectures. We do not scale voltage for memories, so lower voltages help us reduce logic and interconnect energy, but not memory energy. At lower voltages, memories become dominant

  12. SU-F-T-558: ArcCheck for Patient Specific QA in Stereotactic Ablative Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ramachandran, P [Peter MacCallum Cancer Centre, Melbourne (Australia); RMIT University, Bundoora (Australia); Tajaldeen, A; Esen, N; Geso, M [RMIT University, Bundoora (Australia); Taylor, D; Wanigaratne, D; Roozen, K; Kron, T [Peter MacCallum Cancer Centre, Melbourne (Australia)

    2016-06-15

    Purpose: Stereotactic Ablative Radiotherapy (SABR) is one of the most preferred treatment techniques for early stage lung cancer. This technique has been extended to other treatment sites like Spine, Liver, Scapula, Sternum etc., This has resulted in increased physics QA time on machine. In this study, we’ve tested the feasibility of using ArcCheck as an alternative method to replace film dosimetry. Methods: Twelve patients with varied diagnosis of Lung, Liver, scapula, sternum and Spine undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients which include ionization chamber and film dosimetry. The required gamma criteria for each SABR plan to pass QA and proceed to treatment is 95% (3%,1mm). In addition to this routine process, the treatment plans were exported on to an ArcCheck phantom. The planned and measured dose from the ArcCheck device were compared using four different gamma criteria: 2%,2 mm, 3%,2 mm, 3%,1 mm and 3%, 3 mm. In addition to this, we’ve also introduced errors to gantry, collimator and couch angle to assess sensitivity of the ArcCheck with potential delivery errors. Results: The ArcCheck mean passing rates for all twelve cases were 76.1%±9.7% for gamma criteria 3%,1 mm, 89.5%±5.3% for 2%,2 mm, 92.6%±4.2% for 3%,2 mm, and 97.6%±2.4% for 3%,3 mm gamma criteria. When SABR spine cases are excluded, we observe ArcCheck passing rates higher than 95% for all the studied cases with 3%, 3mm, and ArcCheck results in acceptable agreement with the film gamma results. Conclusion: Our ArcCheck results at 3%, 3 mm were found to correlate well with our non-SABR spine routine patient specific QA results (3%,1 mm). We observed significant reduction in QA time on using ArcCheck for SABR QA. This study shows that ArcCheck could replace film dosimetry for all sites except SABR spine.

  13. SU-F-T-558: ArcCheck for Patient Specific QA in Stereotactic Ablative Radiotherapy

    International Nuclear Information System (INIS)

    Ramachandran, P; Tajaldeen, A; Esen, N; Geso, M; Taylor, D; Wanigaratne, D; Roozen, K; Kron, T

    2016-01-01

    Purpose: Stereotactic Ablative Radiotherapy (SABR) is one of the most preferred treatment techniques for early stage lung cancer. This technique has been extended to other treatment sites like Spine, Liver, Scapula, Sternum etc., This has resulted in increased physics QA time on machine. In this study, we’ve tested the feasibility of using ArcCheck as an alternative method to replace film dosimetry. Methods: Twelve patients with varied diagnosis of Lung, Liver, scapula, sternum and Spine undergoing SABR were selected for this study. Pre-treatment QA was performed for all the patients which include ionization chamber and film dosimetry. The required gamma criteria for each SABR plan to pass QA and proceed to treatment is 95% (3%,1mm). In addition to this routine process, the treatment plans were exported on to an ArcCheck phantom. The planned and measured dose from the ArcCheck device were compared using four different gamma criteria: 2%,2 mm, 3%,2 mm, 3%,1 mm and 3%, 3 mm. In addition to this, we’ve also introduced errors to gantry, collimator and couch angle to assess sensitivity of the ArcCheck with potential delivery errors. Results: The ArcCheck mean passing rates for all twelve cases were 76.1%±9.7% for gamma criteria 3%,1 mm, 89.5%±5.3% for 2%,2 mm, 92.6%±4.2% for 3%,2 mm, and 97.6%±2.4% for 3%,3 mm gamma criteria. When SABR spine cases are excluded, we observe ArcCheck passing rates higher than 95% for all the studied cases with 3%, 3mm, and ArcCheck results in acceptable agreement with the film gamma results. Conclusion: Our ArcCheck results at 3%, 3 mm were found to correlate well with our non-SABR spine routine patient specific QA results (3%,1 mm). We observed significant reduction in QA time on using ArcCheck for SABR QA. This study shows that ArcCheck could replace film dosimetry for all sites except SABR spine.

  14. From Preventive to Permissive Checks

    DEFF Research Database (Denmark)

    Sharp, Paul Richard; Weisdorf, Jacob Louis

    The Malthusian "preventive check" mechanism has been well documented for pre-industrial England through evidence for a negativcorrelation between the marriage rate and the price of wheat. Other literature, however, speculates that the correlation was in fact positive from the early nineteenth cen...... shows that this result is not in fact inconsistent with a stylized Malthusian mechanism, and can be understood within the context of an increasing dominance of shocks to aggregate demand rather than to aggregate supply...

  15. Hydrologic response of streams restored with check dams in the Chiricahua Mountains, Arizona

    Science.gov (United States)

    Norman, Laura M.; Brinkerhoff, Fletcher C.; Gwilliam, Evan; Guertin, D. Phillip; Callegary, James B.; Goodrich, David C.; Nagler, Pamela L.; Gray, Floyd

    2016-01-01

    In this study, hydrological processes are evaluated to determine impacts of stream restoration in the West Turkey Creek, Chiricahua Mountains, southeast Arizona, during a summer-monsoon season (June–October of 2013). A paired-watershed approach was used to analyze the effectiveness of check dams to mitigate high flows and impact long-term maintenance of hydrologic function. One watershed had been extensively altered by the installation of numerous small check dams over the past 30 years, and the other was untreated (control). We modified and installed a new stream-gauging mechanism developed for remote areas, to compare the water balance and calculate rainfall–runoff ratios. Results show that even 30 years after installation, most of the check dams were still functional. The watershed treated with check dams has a lower runoff response to precipitation compared with the untreated, most notably in measurements of peak flow. Concerns that downstream flows would be reduced in the treated watershed, due to storage of water behind upstream check dams, were not realized; instead, flow volumes were actually higher overall in the treated stream, even though peak flows were dampened. We surmise that check dams are a useful management tool for reducing flow velocities associated with erosion and degradation and posit they can increase baseflow in aridlands.

  16. Chernobyl new safe confinement

    International Nuclear Information System (INIS)

    Dodd, L.

    2011-01-01

    The author presents the new safe confinement that will be commissioned at Unit 4 of the Chernobyl NPP in 2015. The confinement will ensure that Chernobyl Unit 4 will be placed in an environmentally safe condition for at least next 100 years. The article highlights the current work status, future perspectives and the feasibility of confinement concept [ru

  17. Asymptotically Safe Dark Matter

    DEFF Research Database (Denmark)

    Sannino, Francesco; Shoemaker, Ian M.

    2015-01-01

    We introduce a new paradigm for dark matter (DM) interactions in which the interaction strength is asymptotically safe. In models of this type, the coupling strength is small at low energies but increases at higher energies, and asymptotically approaches a finite constant value. The resulting...... searches are the primary ways to constrain or discover asymptotically safe dark matter....

  18. Model checking the HAVi leader election protocol

    NARCIS (Netherlands)

    J.M.T. Romijn (Judi)

    1999-01-01

    textabstractThe HAVi specification proposes an architecture for audio/video interoperability in home networks. Part of the HAVi specification is a distributed leader election protocol. We have modelled this leader election protocol in Promela and Lotos and have checked several properties with the

  19. Hydrogeology, Ground-Water-Age Dating, Water Quality, and Vulnerability of Ground Water to Contamination in a Part of the Whitewater Valley Aquifer System near Richmond, Indiana, 2002-2003

    Science.gov (United States)

    Buszka, Paul M.; Watson, Lee R.; Greeman, Theodore K.

    2007-01-01

    Assessments of the vulnerability to contamination of ground-water sources used by public-water systems, as mandated by the Federal Safe Drinking Water Act Amendments of 1996, commonly have involved qualitative evaluations based on existing information on the geologic and hydrologic setting. The U.S. Geological Survey National Water-Quality Assessment Program has identified ground-water-age dating; detailed water-quality analyses of nitrate, pesticides, trace elements, and wastewater-related organic compounds; and assessed natural processes that affect those constituents as potential, unique improvements to existing methods of qualitative vulnerability assessment. To evaluate the improvement from use of these methods, in 2002 and 2003, the U.S. Geological Survey, in cooperation with the City of Richmond, Indiana, compiled and interpreted hydrogeologic data and chemical analyses of water samples from seven wells in a part of the Whitewater Valley aquifer system in a former glacial valley near Richmond. This study investigated the application of ground-water-age dating, dissolved-gas analyses, and detailed water-quality analyses to quantitatively evaluate the vulnerability of ground water to contamination and to identify processes that affect the vulnerability to specific contaminants in an area of post-1972 greenfield development.

  20. Member checking: a tool to enhance trustworthiness or merely a nod to validation?

    OpenAIRE

    Birt, Linda; Scott, Suzanne; Cavers, Deborah; Campbell, Christine; Walter, Fiona M

    2016-01-01

    The trustworthiness of results is the bedrock of high quality qualitative research. Member checking, also known as participant or respondent validation, is a technique for exploring the credibility of results. Data or results are returned to participants to check for accuracy and resonance with their experiences. Member checking is often mentioned as one in a list of validation techniques. This simplistic reporting might not acknowledge the value of using the method, nor its juxtaposition wit...

  1. Patterns of attendance to health checks in a municipality setting: the Danish ‘Check Your Health Preventive Program’

    Directory of Open Access Journals (Sweden)

    Anne-Louise Bjerregaard

    2017-03-01

    More than half of a general population voluntarily attended a general health check, despite a resource intensive offer. People with low resources had lower attendance rates. This study adds a detailed description of mutually exclusive groups of attenders, for use in future planning and implementation of preventive actions.

  2. Stove checking behaviour in people with OCD vs. anxious controls.

    Science.gov (United States)

    Bucarelli, Bianca; Purdon, Christine

    2016-12-01

    A growing body of research suggests that the repetition of an action degrades memory for that action, as well as confidence that is has been done correctly. This has important implications for understanding the compulsive repetition of actions characteristic of obsessive compulsive disorder (OCD). At this time, though, much of the research has been conducted on analogue or nonclinical OCD samples in comparison to healthy controls and often using virtual, as opposed to actual, threat stimuli. Furthermore, although it has been argued that people with OCD are overly attentive to threat stimuli, the research on actual attention to threat is scant. People with a principal diagnosis of OCD (n = 30) and people with a clinically significant diagnosis of an anxiety disorder, but no OCD (n = 18) completed measures of memory confidence and responsibility and then underwent a stove-checking task in a functioning kitchen while wearing a portable eye tracking device. Pre- and post-task ratings of harm and responsibility were taken, along with post-task ratings of memory and certainty. People with OCD did not exhibit poorer memory confidence than the anxious control (AC) group, but did report greater trait and state responsibility for harm. The OCD group checked longer than did the AC group and check duration predicted post-task ratings of harm, but to the same extent in both groups. People with OCD attended to threat items less than did the AC group. Greater visual attention to the stove during the checking period was associated with greater post-task ratings of responsibility and harm and with less certainty in and memory for the check - but only for the AC group. The sample size was modest, women were over-represented and problems with the eye tracking device reduced the amount of reliable data available for analysis. Compulsions are complex actions that are mediated by many trait, state and contextual factors. People with OCD may be able to circumvent self

  3. Automation of Geometry Input for Building Code Compliance Check

    DEFF Research Database (Denmark)

    Petrova, Ekaterina Aleksandrova; Johansen, Peter Lind; Jensen, Rasmus Lund

    2017-01-01

    Documentation of compliance with the energy performance regulations at the end of the detailed design phase is mandatory for building owners in Denmark. Therefore, besides multidisciplinary input, the building design process requires various iterative analyses, so that the optimal solutions can...... be identified amongst multiple alternatives. However, meeting performance criteria is often associated with manual data inputs and retroactive modifications of the design. Due to poor interoperability between the authoring tools and the compliance check program, the processes are redundant and inefficient...... from building geometry created in Autodesk Revit and its translation to input for compliance check analysis....

  4. Treatment/Disposal Plan for Drummed Waste from the 300-FF-1 Operable Unit, 618-4 Burial Ground

    International Nuclear Information System (INIS)

    Lerch, J.A.

    1999-01-01

    The objective of this plan is to support selection of a safe, environmentally responsible, and cost-effective treatment and disposal method for drums containing depleted uranium metal chips submerged in oil that have been and will be excavated from the 618-4 Burial Ground. Remediation of the 300-FF-1 Operable Unit, 618-4 Burial Ground was initiated in fiscal year (FY) 1998 as an excavation and removal operation. Routine processes were established to excavate and ship contaminated soil and debris to the Environmental Restoration Disposal Facility (ERDF) for disposal

  5. Ground-water and geohydrologic conditions in Queens County, Long Island, New York

    Science.gov (United States)

    Soren, Julian

    1971-01-01

    salty ground water toward the deepest parts of the cone of depression in central Queens County. Contamination of ground water is probably also occurring from leaking sewers and from pollutants leaking downward from the land surface. Thermal pollution of the ground water has occurred locally where ground water pumped for cooling uses is returned, with elevated temperatures, to the source aquifer through recharge wells. The quality of ground water in Queens County in 1967 was generally satisfactory for public-supply and most industrial uses. However, the rate and distribution of ground-water withdrawals in the county are leading to greater decline of the water table and to increasing contamination of the aquifers. No 'safe limit' on pumpage can be set for the county because limits on the effects of pumping have not been established. A safe limit, at the present stage of urbanization, could range from considerably less than the current average 60 mgd to considerably more over a wide-range of pumping effects and acceptable water quality. However, continued removal of fresh water from storage and deterioration of water quality reduces the value of the county's aquifers, not only for current supply, but also for additional supply to the county and other parts of New York City in times of drought or other emergency.

  6. 75 FR 1734 - Children’s Online Privacy Protection Rule Safe Harbor Proposed Self-Regulatory Guidelines; i-SAFE...

    Science.gov (United States)

    2010-01-13

    ... Proposed Self-Regulatory Guidelines; i-SAFE, Inc. Application for Safe Harbor AGENCY: Federal Trade... for public comment concerning proposed self-regulatory guidelines submitted by i-SAFE, Inc. under the... approval self-regulatory guidelines that would implement the Rule's protections.\\3\\ \\1\\ 64 FR 59888 (1999...

  7. checkCIF/PLATON report Datablock: fa083

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. Structure factors have been supplied for datablock(s) fa083. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC REFEREE. No syntax errors ...

  8. checkCIF/PLATON report Datablock: gitam035

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. Structure factors have been supplied for datablock(s) gitam035. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC REFEREE. No syntax ...

  9. Type checking by domain analysis in Ampersand

    NARCIS (Netherlands)

    Joosten, S.M.M.; Joosten, S.J.C.; Kahl, W.; Winter, M.; Oliveira, J.N.

    2015-01-01

    In the process of incorporating subtyping in relation algebra, an algorithm was found to derive the subtyping relation from the program to be checked. By using domain analysis rather than type inference, this algorithm offers an attractive visualization of the type derivation process. This

  10. Model based feasibility study on bidirectional check valves in wave energy converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2014-01-01

    Discrete fluid power force systems have been proposed as the primary stage for Wave Energy Converters (WEC’s) when converting ocean waves into electricity, this to improve the overall efficiency of wave energy devices. This paper presents a model based feasibility study of using bidirectional check....../Off and bidirectional check valves. Based on the analysis it is found that the energy production may be slightly improved by using bidirectional check valves as compared to on/off valves, due to a decrease in switching losses. Furthermore a reduction in high flow peaks are realised. The downside being increased...

  11. The Canadian experience in performing accuracy checks on administered doses of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Santry, Dallas

    1998-01-01

    A calibration service was introduced in 1986 to assist the Canadian nuclear medicine community in determining more accurately the amount of radioactive material administered to patients for either diagnostic or therapeutic purposes. This aspect of a quality assurance program in nuclear medicine provides an accuracy check on instruments and the technologists using them. The calibration report issued constitutes direct traceability of a facility to a national standards laboratory. Nuclides most frequently calibrated are 99m Tc and 131 I. Others include 67 Ga, 111 In, 123 I, 125 I and 201 Tl. All samples received are analysed for radionuclidic impurities by high-resolution X-ray and gamma-ray spectrometry. Ten years of testing has shown that, except for a few conscientious departments, accuracy checks on radionuclide (dose) calibrators are not a high priority. There are 285 nuclear medicine facilities in Canada and, since there is no legal requirement that the calibrators be checked for accuracy, only 29 have had their instruments checked using this service. Of these, 14 perform annual accuracy checks with NRCC. In this paper, the results of the intercomparisons are described, and quality control problems associated with the use of radionuclide calibrators in nuclear medicine are discussed

  12. Monitoring Ground Subsidence in Hong Kong via Spaceborne Radar: Experiments and Validation

    Directory of Open Access Journals (Sweden)

    Yuxiao Qin

    2015-08-01

    Full Text Available The persistent scatterers interferometry (PSI technique is gradually becoming known for its capability of providing up to millimeter accuracy of measurement on ground displacement. Nevertheless, there is still quite a good amount of doubt regarding its correctness or accuracy. In this paper, we carried out an experiment corroborating the capability of the PSI technique with the help of a traditional survey method in the urban area of Hong Kong, China. Seventy three TerraSAR-X (TSX and TanDEM-X (TDX images spanning over four years are used for the data process. There are three aims of this study. The first is to generate a displacement map of urban Hong Kong and to check for spots with possible ground movements. This information will be provided to the local surveyors so that they can check these specific locations. The second is to validate if the accuracy of the PSI technique can indeed reach the millimeter level in this real application scenario. For validating the accuracy of PSI, four corner reflectors (CR were installed at a construction site on reclaimed land in Hong Kong. They were manually moved up or down by a few to tens of millimeters, and the value derived from the PSI analysis was compared to the true value. The experiment, carried out in unideal conditions, nevertheless proved undoubtedly that millimeter accuracy can be achieved by the PSI technique. The last is to evaluate the advantages and limitations of the PSI technique. Overall, the PSI technique can be extremely useful if used in collaboration with other techniques, so that the advantages can be highlighted and the drawbacks avoided.

  13. Safeness of radiological machinery

    International Nuclear Information System (INIS)

    Yokoyama, Shun

    1979-01-01

    The human factors affecting the safeness of radiological machinery, which are often very big and complicated machines, are described from the stand point of handling. 20 to 50% of the troubles on equipments seem to be caused by men. This percentage will become even higher in highly developed equipments. Human factors have a great influence on the safeness of radiological equipments. As the human factors, there are sensory factors and knowledge factors as well as psychological factors, and the combination of these factors causes mishandling and danger. Medical services at present are divided in various areas, and consist of the teamwork of the people in various professions. Good human relationship, education and control are highly required to secure the safeness. (Kobatake, H.)

  14. Reducing injury risk from body checking in boys' youth ice hockey.

    Science.gov (United States)

    Brooks, Alison; Loud, Keith J; Brenner, Joel S; Demorest, Rebecca A; Halstead, Mark E; Kelly, Amanda K Weiss; Koutures, Chris G; LaBella, Cynthia R; LaBotz, Michele; Martin, Stephanie S; Moffatt, Kody

    2014-06-01

    Ice hockey is an increasingly popular sport that allows intentional collision in the form of body checking for males but not for females. There is a two- to threefold increased risk of all injury, severe injury, and concussion related to body checking at all levels of boys' youth ice hockey. The American Academy of Pediatrics reinforces the importance of stringent enforcement of rules to protect player safety as well as educational interventions to decrease unsafe tactics. To promote ice hockey as a lifelong recreational pursuit for boys, the American Academy of Pediatrics recommends the expansion of nonchecking programs and the restriction of body checking to elite levels of boys' youth ice hockey, starting no earlier than 15 years of age.

  15. From preventive to permissive checks

    DEFF Research Database (Denmark)

    Weisdorf, Jacob Louis; Sharp, Paul Richard

    2009-01-01

    The Malthusian "preventive check" mechanism has been well documented for pre-industrial England through evidence for a negative correlation between the marriage rate and the price of wheat. Other literature, however, speculates that the correlation was in fact positive from the early nineteenth c...... model shows that this result is not in fact inconsistent with a stylised Malthusian mechanism, and can be understood within the context of an increasing dominance of shocks to aggregate demand rather than to aggregate supply....

  16. Consistency checks in beam emission modeling for neutral beam injectors

    International Nuclear Information System (INIS)

    Punyapu, Bharathi; Vattipalle, Prahlad; Sharma, Sanjeev Kumar; Baruah, Ujjwal Kumar; Crowley, Brendan

    2015-01-01

    In positive neutral beam systems, the beam parameters such as ion species fractions, power fractions and beam divergence are routinely measured using Doppler shifted beam emission spectrum. The accuracy with which these parameters are estimated depend on the accuracy of the atomic modeling involved in these estimations. In this work, an effective procedure to check the consistency of the beam emission modeling in neutral beam injectors is proposed. As a first consistency check, at a constant beam voltage and current, the intensity of the beam emission spectrum is measured by varying the pressure in the neutralizer. Then, the scaling of measured intensity of un-shifted (target) and Doppler shifted intensities (projectile) of the beam emission spectrum at these pressure values are studied. If the un-shifted component scales with pressure, then the intensity of this component will be used as a second consistency check on the beam emission modeling. As a further check, the modeled beam fractions and emission cross sections of projectile and target are used to predict the intensity of the un-shifted component and then compared with the value of measured target intensity. An agreement between the predicted and measured target intensities provide the degree of discrepancy in the beam emission modeling. In order to test this methodology, a systematic analysis of Doppler shift spectroscopy data obtained on the JET neutral beam test stand data was carried out

  17. Effectiveness of community based Safe Motherhood promoters in improving the utilization of obstetric care. The case of Mtwara Rural District in Tanzania.

    Science.gov (United States)

    Mushi, Declare; Mpembeni, Rose; Jahn, Albrecht

    2010-04-01

    In Tanzania, maternal mortality ratio remains unacceptably high at 578/100,000 live births. Despite a high coverage of antenatal care (96%), only 44% of deliveries take place within the formal health services. Still, "Ensure skilled attendant at birth" is acknowledged as one of the most effective interventions to reduce maternal deaths. Exploring the potential of community-based interventions in increasing the utilization of obstetric care, the study aimed at developing, testing and assessing a community-based safe motherhood intervention in Mtwara rural District of Tanzania. This community-based intervention was designed as a pre-post comparison study, covering 4 villages with a total population of 8300. Intervention activities were implemented by 50 trained safe motherhood promoters (SMPs). Their tasks focused on promoting early and complete antenatal care visits and delivery with a skilled attendant. Data on all 512 deliveries taking place from October 2004 to November 2006 were collected by the SMPs and cross-checked with health service records. In addition 242 respondents were interviewed with respect to knowledge on safe motherhood issues and their perception of the SMP's performance. Skilled delivery attendance was our primary outcome; secondary outcomes included antenatal care attendance and knowledge on Safe Motherhood issues. Deliveries with skilled attendant significantly increased from 34.1% to 51.4% (rho utilization of obstetric care and a skilled attendant at delivery. This improvement is attributed to the SMPs' home visits and the close collaboration with existing community structures as well as health services.

  18. [Design and implementation of data checking system for Chinese materia medica resources survey].

    Science.gov (United States)

    Wang, Hui; Zhang, Xiao-Bo; Ge, Xiao-Guang; Jin, Yan; Jing, Zhi-Xian; Qi, Yuan-Hua; Wang, Ling; Zhao, Yu-Ping; Wang, Wei; Guo, Lan-Ping; Huang, Lu-Qi

    2017-11-01

    The Chinese material medica resources (CMMR) national survey information management system has collected a large amount of data. To help dealing with data recheck, reduce the work of inside, improve the recheck of survey data from provincial and county level, National Resource Center for Chinese Materia Medical has designed a data checking system for Chinese material medica resources survey based on J2EE technology, Java language, Oracle data base in accordance with the SOA framework. It includes single data check, check score, content manage, check the survey data census data with manual checking and automatic checking about census implementation plan, key research information, general survey information, cultivation of medicinal materials information, germplasm resources information the medicine information, market research information, traditional knowledge information, specimen information of this 9 aspects 20 class 175 indicators in two aspects of the quantity and quality. The established system assists in the completion of the data consistency and accuracy, pushes the county survey team timely to complete the data entry arrangement work, so as to improve the integrity, consistency and accuracy of the survey data, and ensure effective and available data, which lay a foundation for providing accurate data support for national survey of the Chinese material medica resources (CMMR) results summary, and displaying results and sharing. Copyright© by the Chinese Pharmaceutical Association.

  19. The Impact of a Check Dam on Groundwater Recharge and Sedimentation in an Ephemeral Stream

    Directory of Open Access Journals (Sweden)

    Hakan Djuma

    2017-10-01

    Full Text Available Despite the widespread presence of groundwater recharge check dams, there are few studies that quantify their functionality. The objectives of this study are (i to assess groundwater recharge in an ephemeral river with and without a check dam and (ii to assess sediment build-up in the check-dam reservoir. Field campaigns were carried out to measure water flow, water depth, and check-dam topography to establish water volume, evaporation, outflow, and recharge relations, as well as sediment build-up. To quantify the groundwater recharge, a water-balance approach was applied at two locations: at the check dam reservoir area and at an 11 km long natural stretch of the river upstream. Prediction intervals were computed to assess the uncertainties of the results. During the four years of operation, the check dam (storage capacity of 25,000 m3 recharged the aquifer with an average of 3.1 million m3 of the 10.4 million m3 year−1 of streamflow (30%. The lower and upper uncertainty limits of the check dam recharge were 0.1 and 9.6 million m3 year−1, respectively. Recharge from the upstream stretch was 1.5 million m3 year−1. These results indicate that check dams are valuable structures for increasing groundwater resources in semi-arid regions.

  20. Periodic medical check-up among residents of three Nigerian South-western States

    Directory of Open Access Journals (Sweden)

    Saheed Opeyemi Usman

    2016-09-01

    Full Text Available Objectives: General medical examination is a common form of preventive medicine. Periodic medical check-up generally involves thorough history, physical examination and screening of asymptomatic persons by physicians on a regular basis as part of a routine health care process. Periodic medical check-up is considered effective in preventing illness and promoting health and reducing morbidity and mortality. This study is therefore designed to determine the knowledge, attitude and practice of periodic medical check-up among residents of Osun, Ondo and Ekiti States of Nigeria. It is also to determine the influence of educational status on its practice and compare the outcomes in the three states. Materials and Methods: The cross-sectional survey study utilizing both qualitative and quantitative method of data collection was conducted at various locations across the three states. The locations included those of public servants, private sector workers, artisans, traders, business men/women, farmers, among others. Results: 1200 consenting residents participated in the study in each of the three states. 518 (43.2% of the respondents in Ondo State are males while 682 (57.8% are females. 465 (38.8% of the respondents in Ekiti State are males while 735 (61.2% are females. 494 (41.2% of the respondents in Osun State are males while 706 (59.8% are females. The mean age in Ondo, Ekiti and Osun were 43.8 +/- 10.7 years, 44.6 +/- 11.5 years and 41.7 +/- 10.1 years respectively. 89.2%, 88.3% and 87.4% of the respondents are aware of periodic medical check-up in Ondo, Ekiti and Osun states respectively. Conclusion: There is high level of awareness of periodic medical check-up in all three states but the level of practice of routine medical check-up is low. The majority of the respondents probably don't practice it because their health insurance plan does not cover the medical check-up or due to individual/organizational financial constraints. [J Contemp Med 2016

  1. Type Checking with XML Schema in XACT

    DEFF Research Database (Denmark)

    Kirkegaard, Christian; Møller, Anders

    to support XML Schema as type formalism. The technique is able to model advanced features, such as type derivations and overloaded local element declarations, and also datatypes of attribute values and character data. Moreover, we introduce optional type annotations to improve modularity of the type checking...

  2. Towards Model Checking a Spi-Calculus Dialect

    NARCIS (Netherlands)

    Gnesi, S.; Latella, D.; Lenzini, Gabriele

    We present a model checking framework for a spi-calculus dialect which uses a linear time temporal logic for expressing security properties. We have provided our spi-calculus dialect, called SPID, with a semantics based on labeled transition systems (LTS), where the intruder is modeled in the

  3. Verifying large SDL-specifications using model checking

    NARCIS (Netherlands)

    Sidorova, N.; Steffen, M.; Reed, R.; Reed, J.

    2001-01-01

    In this paper we propose a methodology for model-checking based verification of large SDL specifications. The methodology is illustrated by a case study of an industrial medium-access protocol for wireless ATM. To cope with the state space explosion, the verification exploits the layered and modular

  4. System design for safe robotic handling of nuclear materials

    International Nuclear Information System (INIS)

    Drotning, W.; Wapman, W.; Fahrenholtz, J.; Kimberly, H.; Kuhlmann, J.

    1996-01-01

    Robotic systems are being developed by the Intelligent Systems and Robotics Center at Sandia National Laboratories to perform automated handling tasks with radioactive nuclear materials. These systems will reduce the occupational radiation exposure to workers by automating operations which are currently performed manually. Because the robotic systems will handle material that is both hazardous and valuable, the safety of the operations is of utmost importance; assurance must be given that personnel will not be harmed and that the materials and environment will be protected. These safety requirements are met by designing safety features into the system using a layered approach. Several levels of mechanical, electrical and software safety prevent unsafe conditions from generating a hazard, and bring the system to a safe state should an unexpected situation arise. The system safety features include the use of industrial robot standards, commercial robot systems, commercial and custom tooling, mechanical safety interlocks, advanced sensor systems, control and configuration checks, and redundant control schemes. The effectiveness of the safety features in satisfying the safety requirements is verified using a Failure Modes and Effects Analysis. This technique can point out areas of weakness in the safety design as well as areas where unnecessary redundancy may reduce the system reliability

  5. Design and implementation of check out station for large container inspection system

    International Nuclear Information System (INIS)

    Yao Dongsheng; Gao Wenhuan; Kang Kejun

    1997-01-01

    In Large Container Inspection System (LCIS), Check Out Station (COS) is in charge of deciding whether a container is allowed to pass or has to be opened for checking. Several different top level architecture designs for COS are discussed and analyzed according to the practical requirements of COS

  6. A Parallel Decoding Algorithm for Short Polar Codes Based on Error Checking and Correcting

    Science.gov (United States)

    Pan, Xiaofei; Pan, Kegang; Ye, Zhan; Gong, Chao

    2014-01-01

    We propose a parallel decoding algorithm based on error checking and correcting to improve the performance of the short polar codes. In order to enhance the error-correcting capacity of the decoding algorithm, we first derive the error-checking equations generated on the basis of the frozen nodes, and then we introduce the method to check the errors in the input nodes of the decoder by the solutions of these equations. In order to further correct those checked errors, we adopt the method of modifying the probability messages of the error nodes with constant values according to the maximization principle. Due to the existence of multiple solutions of the error-checking equations, we formulate a CRC-aided optimization problem of finding the optimal solution with three different target functions, so as to improve the accuracy of error checking. Besides, in order to increase the throughput of decoding, we use a parallel method based on the decoding tree to calculate probability messages of all the nodes in the decoder. Numerical results show that the proposed decoding algorithm achieves better performance than that of some existing decoding algorithms with the same code length. PMID:25540813

  7. Neighborhood deprivation is strongly associated with participation in a population-based health check

    DEFF Research Database (Denmark)

    Bender, Anne Mette; Kawachi, Ichiro; Jørgensen, Torben

    2015-01-01

    BACKGROUND: We sought to examine whether neighborhood deprivation is associated with participation in a large population-based health check. Such analyses will help answer the question whether health checks, which are designed to meet the needs of residents in deprived neighborhoods, may increase...... participation and prove to be more effective in preventing disease. In Europe, no study has previously looked at the association between neighborhood deprivation and participation in a population-based health check. METHODS: The study population comprised 12,768 persons invited for a health check including...... screening for ischemic heart disease and lifestyle counseling. The study population was randomly drawn from a population of 179,097 persons living in 73 neighborhoods in Denmark. Data on neighborhood deprivation (percentage with basic education, with low income and not in work) and individual socioeconomic...

  8. Efficient Symmetry Reduction and the Use of State Symmetries for Symbolic Model Checking

    Directory of Open Access Journals (Sweden)

    Christian Appold

    2010-06-01

    Full Text Available One technique to reduce the state-space explosion problem in temporal logic model checking is symmetry reduction. The combination of symmetry reduction and symbolic model checking by using BDDs suffered a long time from the prohibitively large BDD for the orbit relation. Dynamic symmetry reduction calculates representatives of equivalence classes of states dynamically and thus avoids the construction of the orbit relation. In this paper, we present a new efficient model checking algorithm based on dynamic symmetry reduction. Our experiments show that the algorithm is very fast and allows the verification of larger systems. We additionally implemented the use of state symmetries for symbolic symmetry reduction. To our knowledge we are the first who investigated state symmetries in combination with BDD based symbolic model checking.

  9. Effectiveness of community based safe motherhood promoters in improving the utilization of obstetric care. The case of Mtwara Rural District in Tanzania

    Directory of Open Access Journals (Sweden)

    Jahn Albrecht

    2010-04-01

    Full Text Available Abstract Background In Tanzania, maternal mortality ratio remains unacceptably high at 578/100,000 live births. Despite a high coverage of antenatal care (96%, only 44% of deliveries take place within the formal health services. Still, "Ensure skilled attendant at birth" is acknowledged as one of the most effective interventions to reduce maternal deaths. Exploring the potential of community-based interventions in increasing the utilization of obstetric care, the study aimed at developing, testing and assessing a community-based safe motherhood intervention in Mtwara rural District of Tanzania. Method This community-based intervention was designed as a pre-post comparison study, covering 4 villages with a total population of 8300. Intervention activities were implemented by 50 trained safe motherhood promoters (SMPs. Their tasks focused on promoting early and complete antenatal care visits and delivery with a skilled attendant. Data on all 512 deliveries taking place from October 2004 to November 2006 were collected by the SMPs and cross-checked with health service records. In addition 242 respondents were interviewed with respect to knowledge on safe motherhood issues and their perception of the SMP's performance. Skilled delivery attendance was our primary outcome; secondary outcomes included antenatal care attendance and knowledge on Safe Motherhood issues. Results Deliveries with skilled attendant significantly increased from 34.1% to 51.4% (ρ Conclusion The study has demonstrated the effectiveness of community-based safe motherhood intervention in promoting the utilization of obstetric care and a skilled attendant at delivery. This improvement is attributed to the SMPs' home visits and the close collaboration with existing community structures as well as health services.

  10. checkCIF/PLATON report Datablock: rup-re

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  11. checkCIF/PLATON report Datablock: compound1

    Indian Academy of Sciences (India)

    checkCIF/PLATON report. You have not supplied any structure factors. As a result the full set of tests cannot be run. THIS REPORT IS FOR GUIDANCE ONLY. IF USED AS PART OF A REVIEW PROCEDURE. FOR PUBLICATION, IT SHOULD NOT REPLACE THE EXPERTISE OF AN EXPERIENCED. CRYSTALLOGRAPHIC ...

  12. checkCIF/PLATON report Datablock: gitam035

    Indian Academy of Sciences (India)

    Moiety formula C7 H3 N2 O8 Sm, O ? Sum formula ... SHFSU01_ALERT_2_B The absolute value of parameter shift to su ratio > 0.10. Absolute value of the ... PLAT934_ALERT_3_C Number of (Iobs-Icalc)/SigmaW > 10 Outliers .... 1 Check.

  13. Safe Cooperating Cyber-Physical Systems using Wireless Communication

    DEFF Research Database (Denmark)

    Pop, Paul; Scholle, Detlef; Sljivo, Irfan

    2017-01-01

    This paper presents an overview of the ECSEL project entitled ―Safe Cooperating Cyber-Physical Systems using Wireless Communication‖ (SafeCOP), which runs during the period 2016–2019. SafeCOP targets safety-related Cooperating Cyber-Physical Systems (CO-CPS) characterised by use of wireless...... detection of abnormal behaviour, triggering if needed a safe degraded mode. SafeCOP will also develop methods and tools, which will be used to produce safety assurance evidence needed to certify cooperative functions. SafeCOP will extend current wireless technologies to ensure safe and secure cooperation...

  14. Efficient family-based model checking via variability abstractions

    DEFF Research Database (Denmark)

    Dimovski, Aleksandar; Al-Sibahi, Ahmad Salim; Brabrand, Claus

    2016-01-01

    with the abstract model checking of the concrete high-level variational model. This allows the use of Spin with all its accumulated optimizations for efficient verification of variational models without any knowledge about variability. We have implemented the transformations in a prototype tool, and we illustrate......Many software systems are variational: they can be configured to meet diverse sets of requirements. They can produce a (potentially huge) number of related systems, known as products or variants, by systematically reusing common parts. For variational models (variational systems or families...... of related systems), specialized family-based model checking algorithms allow efficient verification of multiple variants, simultaneously, in a single run. These algorithms, implemented in a tool Snip, scale much better than ``the brute force'' approach, where all individual systems are verified using...

  15. Checking Thorough Refinement on Modal Transition Systems Is EXPTIME-Complete

    DEFF Research Database (Denmark)

    Benes, Nikola; Kretinsky, Jan; Larsen, Kim Guldstrand

    2009-01-01

    Modal transition systems (MTS), a specification formalism introduced more than 20 years ago, has recently received a considerable attention in several different areas. Many of the fundamental questions related to MTSs have already been answered. However, the problem of the exact computational...... complexity of thorough refinement checking between two finite MTSs remained unsolved. We settle down this question by showing EXPTIME-completeness of thorough refinement checking on finite MTSs. The upper-bound result relies on a novel algorithm running in single exponential time providing a direct goal...

  16. InaSAFE applications in disaster preparedness

    Science.gov (United States)

    Pranantyo, Ignatius Ryan; Fadmastuti, Mahardika; Chandra, Fredy

    2015-04-01

    Disaster preparedness activities aim to reduce the impact of disasters by being better prepared to respond when a disaster occurs. In order to better anticipate requirements during a disaster, contingency planning activities can be undertaken prior to a disaster based on a realistic disaster scenario. InaSAFE is a tool that can inform this process. InaSAFE is a free and open source software that estimates the impact to people and infrastructure from potential hazard scenarios. By using InaSAFE, disaster managers can develop scenarios of disaster impacts (people and infrastructures affected) to inform their contingency plan and emergency response operation plan. While InaSAFE provides the software framework exposure data and hazard data are needed as inputs to run this software. Then InaSAFE can be used to forecast the impact of the hazard scenario to the exposure data. InaSAFE outputs include estimates of the number of people, buildings and roads are affected, list of minimum needs (rice and clean water), and response checklist. InaSAFE is developed by Indonesia's National Disaster Management Agency (BNPB) and the Australian Government, through the Australia-Indonesia Facility for Disaster Reduction (AIFDR), in partnership with the World Bank - Global Facility for Disaster Reduction and Recovery (GFDRR). This software has been used in many parts of Indonesia, including Padang, Maumere, Jakarta, and Slamet Mountain for emergency response and contingency planning.

  17. A characterization of check valve degradation and failure experience in the nuclear power industry

    International Nuclear Information System (INIS)

    Casada, D.A.; Todd, M.D.

    1993-09-01

    Check valve operating problems in recent years have resulted in significant operating transients, increased cost and decreased system availability. As a result, additional attention has beau given to check valves by utilities (resulting in the formation of the Nuclear Industry Check Valve Group), as well as the US Nuclear Regulatory Commission and the American Society of Mechanical Engineers Operation and Maintenance Committee. All these organizations have the fundamental goal of ensuring reliable operation of check valves. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data, available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System, has been conducted. The focus of the review is on check valve failures that have involved significant degradation of the valve internal parts. A variety of parameters are considered, including size, age, system of service, method of failure discovery, the affected valve parts, attributed causes, and corrective actions

  18. Integrated CAE system for nuclear power plants. Development of piping design check system

    International Nuclear Information System (INIS)

    Narikawa, Noboru; Sato, Teruaki

    1994-01-01

    Toshiba Corporation has developed and operated the integrated CAE system for nuclear power plants, the core of which is the engineering data base to manage accurately and efficiently enormous amount of data on machinery, equipment and piping. As the first step of putting knowledge base system to practical use, piping design check system has been developed. By automatically checking up piping design, this system aims at the prevention of overlooking mistakes, efficient design works and the overall quality improvement of design. This system is based on the thought that it supports designers, and final decision is made by designers. This system is composed of the integrated data base, a two-dimensional CAD system and three-dimensional CAD system. The piping design check system is one of the application systems of the integrated CAE system. Object-oriented programming is the base of the piping design check system, and design knowledge and CAD data are necessary. As to the method of realizing the check system, the flow of piping design, the checkup functions, the checkup of interference and attribute base, and the integration of the system are explained. (K.I)

  19. 12 CFR 229.53 - Substitute check indemnity.

    Science.gov (United States)

    2010-01-01

    ... expenses of representation) related to the substitute check. (2) Comparative negligence. (i) If a loss... negligence or failure to act in good faith, then the indemnity amount described in paragraph (b)(1) of this section shall be reduced in proportion to the amount of negligence or bad faith attributable to the...

  20. NPP planning based on analysis of ground vibration caused by collapse of large-scale cooling towers

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Feng; Ji, Hongkui [Department of Structural Engineering, Tongji University, No. 1239 Siping Road, Shanghai 200092 (China); Gu, Xianglin, E-mail: gxl@tongji.edu.cn [Department of Structural Engineering, Tongji University, No. 1239 Siping Road, Shanghai 200092 (China); Li, Yi [Department of Structural Engineering, Tongji University, No. 1239 Siping Road, Shanghai 200092 (China); Wang, Mingreng; Lin, Tao [East China Electric Power Design Institute Co., Ltd, No. 409 Wuning Road, Shanghai 200063 (China)

    2015-12-15

    Highlights: • New recommendations for NPP planning were addressed taking into account collapse-induced ground vibration. • Critical factors influencing the collapse-induced ground vibration were investigated. • Comprehensive approach was presented to describe the initiation and propagation of collapse-induced disaster. - Abstract: Ground vibration induced by collapse of large-scale cooling towers can detrimentally influence the safe operation of adjacent nuclear-related facilities. To prevent and mitigate these hazards, new planning methods for nuclear power plants (NPPs) were studied considering the influence of these hazards. First, a “cooling tower-soil” model was developed, verified, and used as a numerical means to investigate ground vibration. Afterwards, five critical factors influencing collapse-induced ground vibration were analyzed in-depth. These influencing factors included the height and weight of the towers, accidental loads, soil properties, overlying soil, and isolation trench. Finally, recommendations relating to the control and mitigation of collapse-induced ground vibration in NPP planning were proposed, which addressed five issues, i.e., appropriate spacing between a cooling tower and the nuclear island, control of collapse modes, sitting of a cooling tower and the nuclear island, application of vibration reduction techniques, and the influence of tower collapse on surroundings.

  1. Safe Minimum Internal Temperature Chart

    Science.gov (United States)

    ... Internal Temperature Chart Safe steps in food handling, cooking, and storage are essential in preventing foodborne illness. You can't see, smell, or taste harmful bacteria that may cause illness. In every step of food preparation, follow the four guidelines to keep food safe: ...

  2. Automata-Based CSL Model Checking

    DEFF Research Database (Denmark)

    Zhang, Lijun; Jansen, David N.; Nielson, Flemming

    2011-01-01

    For continuous-time Markov chains, the model-checking problem with respect to continuous-time stochastic logic (CSL) has been introduced and shown to be decidable by Aziz, Sanwal, Singhal and Brayton in 1996. The presented decision procedure, however, has exponential complexity. In this paper, we...... probability can then be approximated in polynomial time (using uniformization). This makes the present work the centerpiece of a broadly applicable full CSL model checker. Recently, the decision algorithm by Aziz et al. was shown to be incorrect in general. In fact, it works only for stratified CTMCs...

  3. Monitor-Based Statistical Model Checking for Weighted Metric Temporal Logic

    DEFF Research Database (Denmark)

    Bulychev, Petr; David, Alexandre; Larsen, Kim Guldstrand

    2012-01-01

    We present a novel approach and implementation for ana- lysing weighted timed automata (WTA) with respect to the weighted metric temporal logic (WMTL≤ ). Based on a stochastic semantics of WTAs, we apply statistical model checking (SMC) to estimate and test probabilities of satisfaction with desi......We present a novel approach and implementation for ana- lysing weighted timed automata (WTA) with respect to the weighted metric temporal logic (WMTL≤ ). Based on a stochastic semantics of WTAs, we apply statistical model checking (SMC) to estimate and test probabilities of satisfaction...

  4. On Diagnostic Checking of Vector ARMA-GARCH Models with Gaussian and Student-t Innovations

    Directory of Open Access Journals (Sweden)

    Yongning Wang

    2013-04-01

    Full Text Available This paper focuses on the diagnostic checking of vector ARMA (VARMA models with multivariate GARCH errors. For a fitted VARMA-GARCH model with Gaussian or Student-t innovations, we derive the asymptotic distributions of autocorrelation matrices of the cross-product vector of standardized residuals. This is different from the traditional approach that employs only the squared series of standardized residuals. We then study two portmanteau statistics, called Q1(M and Q2(M, for model checking. A residual-based bootstrap method is provided and demonstrated as an effective way to approximate the diagnostic checking statistics. Simulations are used to compare the performance of the proposed statistics with other methods available in the literature. In addition, we also investigate the effect of GARCH shocks on checking a fitted VARMA model. Empirical sizes and powers of the proposed statistics are investigated and the results suggest a procedure of using jointly Q1(M and Q2(M in diagnostic checking. The bivariate time series of FTSE 100 and DAX index returns is used to illustrate the performance of the proposed portmanteau statistics. The results show that it is important to consider the cross-product series of standardized residuals and GARCH effects in model checking.

  5. Speed checks on the CERN site

    CERN Multimedia

    2007-01-01

    In view of the significant number of speeding incidents that have been reported, CERN will shortly start to carry out speed checks on the site. The radar used for this purpose will show drivers the speed measured. The disciplinary measures taken against those exceeding the authorised limit (generally 50 k.p.h.) will include a ban from driving on the site for a minimum of one month. Maximilian Metzger
Secretary-General

  6. Development of the system for checking attendance of the lecture at the university using the card reader

    OpenAIRE

    田中,武; 大村,道郎; 楠,茂之; 安井,良親; 山田,明宏

    2003-01-01

    Development of the system for checking attendance of the lecture at the university using the card reader was demonstrated. The rate of checking attendance of the lecture was about 4 to 12 students per minute. The break time of lecture at the Hiroshima Institute of Technology was 10 minute. Therefore, it is possible to check about 40 students' attendance of the lecture for the break time. Also, the probability that check exactly attendance was about 50%. The real time system for checking atten...

  7. checkCIF/PLATON report Datablock: 1b

    Indian Academy of Sciences (India)

    4 ALERT level G = General information/check it is not something unexpected. 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 2 ALERT type 2 Indicator that the structure ... However, the purpose of your study may justify the reported deviations and the more serious of these should normally be ...

  8. checkCIF/PLATON report Datablock: exp_2816

    Indian Academy of Sciences (India)

    4 ALERT level G = General information/check it is not something unexpected. 1 ALERT type 1 CIF construction/syntax error, inconsistent or missing data. 2 ALERT type 2 Indicator that the structure ... However, the purpose of your study may justify the reported deviations and the more serious of these should normally be ...

  9. What checkers actually check: an eye tracking study of inhibitory control and working memory.

    Directory of Open Access Journals (Sweden)

    Ben Harkin

    Full Text Available Not only is compulsive checking the most common symptom in Obsessive Compulsive Disorder (OCD with an estimated prevalence of 50-80% in patients, but approximately ∼15% of the general population reveal subclinical checking tendencies that impact negatively on their performance in daily activities. Therefore, it is critical to understand how checking affects attention and memory in clinical as well as subclinical checkers. Eye fixations are commonly used as indicators for the distribution of attention but research in OCD has revealed mixed results at best.Here we report atypical eye movement patterns in subclinical checkers during an ecologically valid working memory (WM manipulation. Our key manipulation was to present an intermediate probe during the delay period of the memory task, explicitly asking for the location of a letter, which, however, had not been part of the encoding set (i.e., misleading participants. Using eye movement measures we now provide evidence that high checkers' inhibitory impairments for misleading information results in them checking the contents of WM in an atypical manner. Checkers fixate more often and for longer when misleading information is presented than non-checkers. Specifically, checkers spend more time checking stimulus locations as well as locations that had actually been empty during encoding.We conclude that these atypical eye movement patterns directly reflect internal checking of memory contents and we discuss the implications of our findings for the interpretation of behavioural and neuropsychological data. In addition our results highlight the importance of ecologically valid methodology for revealing the impact of detrimental attention and memory checking on eye movement patterns.

  10. Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Eric C., E-mail: eford@uw.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States); Terezakis, Stephanie; Souranis, Annette; Harris, Kendra [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland (United States); Gay, Hiram; Mutic, Sasa [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States)

    2012-11-01

    Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 {+-} 2.3 (mean {+-} SD) and 2.6 {+-} 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that

  11. Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology

    International Nuclear Information System (INIS)

    Ford, Eric C.; Terezakis, Stephanie; Souranis, Annette; Harris, Kendra; Gay, Hiram; Mutic, Sasa

    2012-01-01

    Purpose: To quantify the error-detection effectiveness of commonly used quality control (QC) measures. Methods: We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. Results: In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 ± 2.3 (mean ± SD) and 2.6 ± 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. Conclusions: The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further

  12. Quality control quantification (QCQ): a tool to measure the value of quality control checks in radiation oncology.

    Science.gov (United States)

    Ford, Eric C; Terezakis, Stephanie; Souranis, Annette; Harris, Kendra; Gay, Hiram; Mutic, Sasa

    2012-11-01

    To quantify the error-detection effectiveness of commonly used quality control (QC) measures. We analyzed incidents from 2007-2010 logged into a voluntary in-house, electronic incident learning systems at 2 academic radiation oncology clinics. None of the incidents resulted in patient harm. Each incident was graded for potential severity using the French Nuclear Safety Authority scoring scale; high potential severity incidents (score >3) were considered, along with a subset of 30 randomly chosen low severity incidents. Each report was evaluated to identify which of 15 common QC checks could have detected it. The effectiveness was calculated, defined as the percentage of incidents that each QC measure could detect, both for individual QC checks and for combinations of checks. In total, 4407 incidents were reported, 292 of which had high-potential severity. High- and low-severity incidents were detectable by 4.0 ± 2.3 (mean ± SD) and 2.6 ± 1.4 QC checks, respectively (P<.001). All individual checks were less than 50% sensitive with the exception of pretreatment plan review by a physicist (63%). An effectiveness of 97% was achieved with 7 checks used in combination and was not further improved with more checks. The combination of checks with the highest effectiveness includes physics plan review, physician plan review, Electronic Portal Imaging Device-based in vivo portal dosimetry, radiation therapist timeout, weekly physics chart check, the use of checklists, port films, and source-to-skin distance checks. Some commonly used QC checks such as pretreatment intensity modulated radiation therapy QA do not substantially add to the ability to detect errors in these data. The effectiveness of QC measures in radiation oncology depends sensitively on which checks are used and in which combinations. A small percentage of errors cannot be detected by any of the standard formal QC checks currently in broad use, suggesting that further improvements are needed. These data

  13. Safe affordable fission engine (SAFE 30) module conductivity test thermal model correlation

    International Nuclear Information System (INIS)

    Roman, Jose

    2001-01-01

    The SAFE 30 is a simple, robust space fission power system that is comprised of several independent modules. Each module contains 4 fuel tubes bonded to a central heatpipe. Fission energy is conducted from the fuel tubes to the heatpipe, which in turn transfers the energy to a power conversion system. This paper benchmarks a thermal model of the SAFE 30 with actual test data from simulated SAFE 30 module tests. Two 'dummy' SAFE 30 modules were fabricated - each consisted of 4 1-inch dia. tubes (simulating the fuel tubes) bonded to a central '1' dia. tube (simulating the heatpipe). In the first module the fuel tubes were simply brazed to the heatpipe along the line of contact (leaving void space in the interstices), and in the second module the tubes and heatpipe were brazed via tri-cusps that completely fill the interstices between the tubes. In these tests, fission energy is simulated by placing resistance heaters within each of the 4 fuel tubes. The tests were conducted in a vacuum chamber in 4 configurations: tri-cusps filled with and without an outer insulation wrap, and no tri-cusps with and without an outer insulation wrap. The baseline SAFE 30 configuration uses the brazed tri-cusps. During the tests, the power applied to the heaters was varied in a stepwise fashion, until a steady-state temperature profile was reached. These temperature levels varied between 773 K and 1073 K. To benchmark the thermal model, the input energy and chamber surface temperature were used as boundary conditions for the model. The analytical results from the nodes at the same location as the test thermocouples were plotted again test data to determinate the accuracy of the analysis. The unknown variables on the analysis are the radiation emissivity of the pipe and chamber and the radiation view factor between the module and the chamber. A correlation was determined using a parametric analysis by varying the surface emissivity and view factor until a good match was reached. This

  14. Reliability estimation for check valves and other components

    International Nuclear Information System (INIS)

    McElhaney, K.L.; Staunton, R.H.

    1996-01-01

    For years the nuclear industry has depended upon component operational reliability information compiled from reliability handbooks and other generic sources as well as private databases generated by recognized experts both within and outside the nuclear industry. Regrettably, these technical bases lacked the benefit of large-scale operational data and comprehensive data verification, and did not take into account the parameters and combinations of parameters that affect the determination of failure rates. This paper briefly examines the historic use of generic component reliability data, its sources, and its limitations. The concept of using a single failure rate for a particular component type is also examined. Particular emphasis is placed on check valves due to the information available on those components. The Appendix presents some of the results of the extensive analyses done by Oak Ridge National Laboratory (ORNL) on check valve performance

  15. Constraint-based deadlock checking of high-level specifications

    DEFF Research Database (Denmark)

    Hallerstede, Stefan; Leuschel, Michael

    2011-01-01

    Establishing the absence of deadlocks is important in many applications of formal methods. The use of model checking for finding deadlocks in formal models is limited because in many industrial applications the state space is either infinite or much too large to be explored exhaustively. In this ......Establishing the absence of deadlocks is important in many applications of formal methods. The use of model checking for finding deadlocks in formal models is limited because in many industrial applications the state space is either infinite or much too large to be explored exhaustively......B's Prolog kernel, such as reification of membership and arithmetic constraints. ProB typically finds counter examples to deadlock-freedom constraints, a formula of about 900 partly nested conjunctions and disjunction among them 80 arithmetic and 150 set-theoretic predicates (in total a formula of 30 pages...

  16. Steering teens safe: a randomized trial of a parent-based intervention to improve safe teen driving.

    Science.gov (United States)

    Peek-Asa, Corinne; Cavanaugh, Joseph E; Yang, Jingzhen; Chande, Vidya; Young, Tracy; Ramirez, Marizen

    2014-07-31

    Crashes are the leading cause of death for teens, and parent-based interventions are a promising approach. We assess the effectiveness of Steering Teens Safe, a parent-focused program to increase safe teen driving. Steering Teens Safe aimed to improve parental communication with teens about safe driving using motivational interviewing techniques in conjunction with 19 safe driving lessons. A randomized controlled trial involved 145 parent-teen dyads (70 intervention and 75 control). Intervention parents received a 45-minute session to learn the program with four follow-up phone sessions, a DVD, and a workbook. Control parents received a standard brochure about safe driving. Scores were developed to measure teen-reported quantity and quality of parental communication about safe driving. The main outcome measure was a previously validated Risky Driving Score reported by teens. Because the Score was highly skewed, a generalized linear model based on a gamma distribution was used for analysis. Intervention teens ranked their parent's success in talking about driving safety higher than control teens (p = 0.035) and reported that their parents talked about more topics (non-significant difference). The Risky Driving Score was 21% lower in intervention compared to control teens (85% CI = 0.60, 1.00). Interaction between communication quantity and the intervention was examined. Intervention teens who reported more successful communication had a 42% lower Risky Driving Score (95% CI = 0.37, 0.94) than control parents with less successful communication. This program had a positive although not strong effect, and it may hold the most promise in partnership with other programs, such as Driver's Education or Graduated Driver's License policies. ClinicalTrials.gov NCT01014923. Registered Nov. 16, 2009.

  17. Staying Safe in the Water

    Centers for Disease Control (CDC) Podcasts

    In this podcast, Dr. Julie Gilchrist, a pediatrician and medical epidemiologist from CDC’s Injury Center, talks about staying safe in the water. Tips are for all audiences, with a focus on preventing drownings and keeping children safe in and around the pool, lake, or ocean.

  18. Safe biodegradable fluorescent particles

    Science.gov (United States)

    Martin, Sue I [Berkeley, CA; Fergenson, David P [Alamo, CA; Srivastava, Abneesh [Santa Clara, CA; Bogan, Michael J [Dublin, CA; Riot, Vincent J [Oakland, CA; Frank, Matthias [Oakland, CA

    2010-08-24

    A human-safe fluorescence particle that can be used for fluorescence detection instruments or act as a safe simulant for mimicking the fluorescence properties of microorganisms. The particle comprises a non-biological carrier and natural fluorophores encapsulated in the non-biological carrier. By doping biodegradable-polymer drug delivery microspheres with natural or synthetic fluorophores, the desired fluorescence can be attained or biological organisms can be simulated without the associated risks and logistical difficulties of live microorganisms.

  19. Effects of monetary reward and punishment on information checking behaviour.

    Science.gov (United States)

    Li, Simon Y W; Cox, Anna L; Or, Calvin; Blandford, Ann

    2016-03-01

    Two experiments were conducted to examine whether checking one's own work can be motivated by monetary reward and punishment. Participants were randomly assigned to one of three conditions: a flat-rate payment for completing the task (Control); payment increased for error-free performance (Reward); payment decreased for error performance (Punishment). Experiment 1 (N = 90) was conducted with liberal arts students, using a general data-entry task. Experiment 2 (N = 90) replicated Experiment 1 with clinical students and a safety-critical 'cover story' for the task. In both studies, Reward and Punishment resulted in significantly fewer errors, more frequent and longer checking, than Control. No such differences were obtained between the Reward and Punishment conditions. It is concluded that error consequences in terms of monetary reward and punishment can result in more accurate task performance and more rigorous checking behaviour than errors without consequences. However, whether punishment is more effective than reward, or vice versa, remains inconclusive. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. Safe Haven.

    Science.gov (United States)

    Bush, Gail

    2003-01-01

    Discusses school libraries as safe havens for teenagers and considers elements that foster that atmosphere, including the physical environment, lack of judgments, familiarity, leisure, and a welcoming nature. Focuses on the importance of relationships, and taking the time to listen to teens and encourage them. (LRW)

  1. Flight Testing a Real-Time Hazard Detection System for Safe Lunar Landing on the Rocket-Powered Morpheus Vehicle

    Science.gov (United States)

    Trawny, Nikolas; Huertas, Andres; Luna, Michael E.; Villalpando, Carlos Y.; Martin, Keith E.; Carson, John M.; Johnson, Andrew E.; Restrepo, Carolina; Roback, Vincent E.

    2015-01-01

    The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.

  2. Exercise: When to Check with Your Doctor First

    Science.gov (United States)

    ... check with your doctor before you start to exercise. By Mayo Clinic Staff Regular exercise can help you control your weight, reduce your ... talk to your doctor before starting a new exercise routine. Although moderate physical activity such as brisk ...

  3. State Space Reduction for Model Checking Agent Programs

    NARCIS (Netherlands)

    S.-S.T.Q. Jongmans (Sung-Shik); K.V. Hindriks; M.B. van Riemsdijk; L. Dennis; O. Boissier; R.H. Bordini (Rafael)

    2012-01-01

    htmlabstractState space reduction techniques have been developed to increase the efficiency of model checking in the context of imperative programming languages. Unfortunately, these techniques cannot straightforwardly be applied to agents: the nature of states in the two programming paradigms

  4. Role of check operators in achieving operational excellence at Virginia Power's nuclear stations

    International Nuclear Information System (INIS)

    Shriver, B.L.; Williams, T.M.; Stewart, W.L.

    1987-01-01

    Virginia Power has implemented a Check Operator Program as a part of its commitment to excellence in the operation of the North Anna and Surry nuclear power stations. The Check Operator Program utilizes highly qualified licensed personnel to independently evaluate the performance of licensed operators and senior operators during normal, abnormal and simulated emergency conditions. Emphasis is placed upon individual and team performance as well as the procedures and training which support the operators. The check operators report to line management to ensure that their recommendations are implemented into the overall operations philosophy of the power station

  5. CrossCheck: an open-source web tool for high-throughput screen data analysis.

    Science.gov (United States)

    Najafov, Jamil; Najafov, Ayaz

    2017-07-19

    Modern high-throughput screening methods allow researchers to generate large datasets that potentially contain important biological information. However, oftentimes, picking relevant hits from such screens and generating testable hypotheses requires training in bioinformatics and the skills to efficiently perform database mining. There are currently no tools available to general public that allow users to cross-reference their screen datasets with published screen datasets. To this end, we developed CrossCheck, an online platform for high-throughput screen data analysis. CrossCheck is a centralized database that allows effortless comparison of the user-entered list of gene symbols with 16,231 published datasets. These datasets include published data from genome-wide RNAi and CRISPR screens, interactome proteomics and phosphoproteomics screens, cancer mutation databases, low-throughput studies of major cell signaling mediators, such as kinases, E3 ubiquitin ligases and phosphatases, and gene ontological information. Moreover, CrossCheck includes a novel database of predicted protein kinase substrates, which was developed using proteome-wide consensus motif searches. CrossCheck dramatically simplifies high-throughput screen data analysis and enables researchers to dig deep into the published literature and streamline data-driven hypothesis generation. CrossCheck is freely accessible as a web-based application at http://proteinguru.com/crosscheck.

  6. Development of a computerized procedure system on the basis of formalized action and check

    International Nuclear Information System (INIS)

    Jung, Y. S.; Shin, Y. C.; Jung, K. H.; Sung, C. H.

    1999-01-01

    A computerized procedure system was developed on the basis of formalized action and check. The actions and checks are rendered into two dimensional flowchart with foldable, dynamic, and interactive functions. The action and check are evaluated by computer automatically, and can be overridden by operator if necessary. Detail of each action and check is described in the logic tree with several boolean instruction set and n out m of mathematical operator. Computer supports operators to execute the boolean instruction providing relevant process parameters and control devices. In spite of all these computer support, its inner logic is simple and transparent to operators to keep them in the control loop. The boolean instruction can have 3 states. And n out m operator is defined on the 3 states. The definition minimizes not only number of context switching in procedure execution, but also enables evaluation of the action and check. The process parameters are presented in both text label and graphical symbol to improve readability. Moreover, new mechanism to access any part of a procedure is devised while keeping the main stream of procedure execution

  7. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  8. Model checking optimal finite-horizon control for probabilistic gene regulatory networks.

    Science.gov (United States)

    Wei, Ou; Guo, Zonghao; Niu, Yun; Liao, Wenyuan

    2017-12-14

    Probabilistic Boolean networks (PBNs) have been proposed for analyzing external control in gene regulatory networks with incorporation of uncertainty. A context-sensitive PBN with perturbation (CS-PBNp), extending a PBN with context-sensitivity to reflect the inherent biological stability and random perturbations to express the impact of external stimuli, is considered to be more suitable for modeling small biological systems intervened by conditions from the outside. In this paper, we apply probabilistic model checking, a formal verification technique, to optimal control for a CS-PBNp that minimizes the expected cost over a finite control horizon. We first describe a procedure of modeling a CS-PBNp using the language provided by a widely used probabilistic model checker PRISM. We then analyze the reward-based temporal properties and the computation in probabilistic model checking; based on the analysis, we provide a method to formulate the optimal control problem as minimum reachability reward properties. Furthermore, we incorporate control and state cost information into the PRISM code of a CS-PBNp such that automated model checking a minimum reachability reward property on the code gives the solution to the optimal control problem. We conduct experiments on two examples, an apoptosis network and a WNT5A network. Preliminary experiment results show the feasibility and effectiveness of our approach. The approach based on probabilistic model checking for optimal control avoids explicit computation of large-size state transition relations associated with PBNs. It enables a natural depiction of the dynamics of gene regulatory networks, and provides a canonical form to formulate optimal control problems using temporal properties that can be automated solved by leveraging the analysis power of underlying model checking engines. This work will be helpful for further utilization of the advances in formal verification techniques in system biology.

  9. More than a Safe Space

    Science.gov (United States)

    Sadowski, Michael

    2016-01-01

    Over the past three decades, much of the conversation about LGBTQ students in schools has centered on safety--anti-bullying policies, the "safe space" of gay-straight alliances, and "safe zones" marked by rainbow-colored stickers on classroom doors. In this article, Michael Sadowski argues that it's time to move beyond safety…

  10. 10 CFR 73.28 - Security background checks for secure transfer of nuclear materials.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Security background checks for secure transfer of nuclear... PLANTS AND MATERIALS Physical Protection of Special Nuclear Material in Transit § 73.28 Security background checks for secure transfer of nuclear materials. Licensees are excepted from the security...

  11. checkCIF/PLATON report Datablock: 1b

    Indian Academy of Sciences (India)

    checkCIF was carefully designed to identify outliers and unusual parameters, but every test has its limitations and alerts that are not important in a particular case may appear. Conversely, the absence of alerts does not guarantee there are no aspects of the results needing attention. It is up to the individual to critically assess ...

  12. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  13. Stochastic Local Search for Core Membership Checking in Hedonic Games

    Science.gov (United States)

    Keinänen, Helena

    Hedonic games have emerged as an important tool in economics and show promise as a useful formalism to model multi-agent coalition formation in AI as well as group formation in social networks. We consider a coNP-complete problem of core membership checking in hedonic coalition formation games. No previous algorithms to tackle the problem have been presented. In this work, we overcome this by developing two stochastic local search algorithms for core membership checking in hedonic games. We demonstrate the usefulness of the algorithms by showing experimentally that they find solutions efficiently, particularly for large agent societies.

  14. Calibration, checking and physical corrections for a new dual-spaced neutron porosity tool

    International Nuclear Information System (INIS)

    Smith, M.P.

    1986-01-01

    A new dual-spaced neutron tool has been developed that features high count rates and improved statistical precision and log repeatability. Environmental corrections including borehole diameter, standoff, and lithology are at acceptable levels for DSN-II. The effects of varying source-to-detector spacings and shielding are summarized. Porosity measurement resolution and statistical precision are discussed and it is indicated how tradeoffs between higher count rates and increased environmental corrections must be considered. The absolute calibration of a standard tool is based on its response to limestone test pits, field data, and theoretical calculations. Test data for actual manufactured tools are presented. Shop calibration and wellsite check procedures are discussed. The advantages of multiposition check operations are explained, including reduced sensitivity to check block positioning and external environment. An analysis is presented of errors from tool manufacturing, calibration, and check procedures. A generalized theory of neutron scattering and absorption has been developed to correct dual-spaced neutron logs for unusual minerals and fluids

  15. Study on Vibration Reduction Method for a Subway Station in Soft Ground

    Directory of Open Access Journals (Sweden)

    Xian-Feng Ma

    2017-01-01

    Full Text Available With the rapid development of metro system in urban areas, vibration and its impact on adjacent structures caused by metro operation have drawn much attention of researches and worries relating to it have risen. This paper analyzed the vibration attenuation and the environment impact by a case study of a subway station in soft ground with adjacent laboratory building. A method of setting a compound separation barrier surrounding the station is checked and different materials used in the barrier have been tried and tested through numerical analysis. Key parameters of the material and the effects of vibration reduction are studied with the purpose that similar methodology and findings can be referenced in future practices.

  16. Shearlet transform in aliased ground roll attenuation and its comparison with f-k filtering and curvelet transform

    Science.gov (United States)

    Abolfazl Hosseini, Seyed; Javaherian, Abdolrahim; Hassani, Hossien; Torabi, Siyavash; Sadri, Maryam

    2015-06-01

    Ground roll, which is a Rayleigh surface wave that exists in land seismic data, may mask reflections. Sometimes ground roll is spatially aliased. Attenuation of aliased ground roll is of importance in seismic data processing. Different methods have been developed to attenuate ground roll. The shearlet transform is a directional and multidimensional transform that generates subimages of an input image in different directions and scales. Events with different dips are separated in these subimages. In this study, the shearlet transform is used to attenuate the aliased ground roll. To do this, a shot record is divided into several segments, and the appropriate mute zone is defined for all segments. The shearlet transform is applied to each segment. The subimages related to the non-aliased and aliased ground roll are identified by plotting the energy distributions of subimages with visual checking. Then, muting filters are used on selected subimages. The inverse shearlet transform is applied to the filtered segment. This procedure is repeated for all segments. Finally, all filtered segments are merged using the Hanning window. This method of aliased ground roll attenuation was tested on a synthetic dataset and a field shot record from the west of Iran. The synthetic shot record included strong aliased ground roll, whereas the field shot record did not. To produce the strong aliased ground roll on the field shot record, the data were resampled in the offset direction from 30 to 60 m. To show the performance of the shearlet transform in attenuating the aliased ground roll, we compared the shearlet transform with the f-k filtering and curvelet transform. We showed that the performance of the shearlet transform in the aliased ground roll attenuation is better than that of the f-k filtering and curvelet transform in both the synthetic and field shot records. However, when the dip and frequency content of the aliased ground roll are the same as the reflections, ability of

  17. An analysis of the ArcCHECK-MR diode array's performance for ViewRay quality assurance.

    Science.gov (United States)

    Ellefson, Steven T; Culberson, Wesley S; Bednarz, Bryan P; DeWerd, Larry A; Bayouth, John E

    2017-07-01

    The ArcCHECK-MR diode array utilizes a correction system with a virtual inclinometer to correct the angular response dependencies of the diodes. However, this correction system cannot be applied to measurements on the ViewRay MR-IGRT system due to the virtual inclinometer's incompatibility with the ViewRay's multiple simultaneous beams. Additionally, the ArcCHECK's current correction factors were determined without magnetic field effects taken into account. In the course of performing ViewRay IMRT quality assurance with the ArcCHECK, measurements were observed to be consistently higher than the ViewRay TPS predictions. The goals of this study were to quantify the observed discrepancies and test whether applying the current factors improves the ArcCHECK's accuracy for measurements on the ViewRay. Gamma and frequency analysis were performed on 19 ViewRay patient plans. Ion chamber measurements were performed at a subset of diode locations using a PMMA phantom with the same dimensions as the ArcCHECK. A new method for applying directionally dependent factors utilizing beam information from the ViewRay TPS was developed in order to analyze the current ArcCHECK correction factors. To test the current factors, nine ViewRay plans were altered to be delivered with only a single simultaneous beam and were measured with the ArcCHECK. The current correction factors were applied using both the new and current methods. The new method was also used to apply corrections to the original 19 ViewRay plans. It was found the ArcCHECK systematically reports doses higher than those actually delivered by the ViewRay. Application of the current correction factors by either method did not consistently improve measurement accuracy. As dose deposition and diode response have both been shown to change under the influence of a magnetic field, it can be concluded the current ArcCHECK correction factors are invalid and/or inadequate to correct measurements on the ViewRay system. © 2017 The

  18. Comparative evaluation of Map-Check and Arc-Check for dosimetric verification in patients treaties with IMRT; Evaluacion comparativa de MapCHECK y ArcCHECK para verificacion dosimetrica en pacientes tratados con IMRT

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, B.; Marquina, J.; Ramirez, J.; Gonzales, A., E-mail: bertha.garcia@aliada.com.pe [ALIADA, Oncologia Integral, Av. Jose Galvez Barrenechea 1044, San Isidro, Lima 27 (Peru)

    2014-08-15

    The dosimetric controls that are realized to the patients in the Intensity-Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) techniques; are indispensable since allows in real time to verify the quantity of imparted dose to the patient, these controls should be carried out every time that will begin a treatment, because these techniques impart dose dynamically modulating the dose intensity and movements of the Multi leaf Collimator (MLC), for they exist different diodes devices prepared in spiral (3-D) and planar form (2-D); that allows to estimate the dose fluence in a certain area. Treatment studies for head and neck with IMRT were compared regarding the reading average carried out by the diodes in the corresponding areas, using the criteria of the gamma index like dose difference 3% or 3m m of distance for both diode arrangements, in the IMRT case was found in Arc-Check a minor difference of 3/3 for an average of 99.37% of read diodes in a correct way contrary to the reading obtained with the Map-Check 3/3 an average of difference of 96.19%; in IMRT the difference was lower due to different factors like sensibility of the diodes reading, resolution, diodes disposition, as well as the average reading of entrance and exit of the radiation beams. Within the parameters delivered by the diodes arrangement is considered the positioning correction for both acceptance indexes like the gamma factor and the Distance-to-agreement (Dta), the existent difference of reading in factor gamma and Dta fundamentally is the way in like they compare the dose distribution; the Gamma uses dose averages of high and low gradients and Dta use only averages of areas of high gradients between the nearest points giving the distance as a result among the distribution point and the nearest point what makes stricter. (Author)

  19. Effectiveness of the GoCheck Kids Vision Screener in Detecting Amblyopia Risk Factors.

    Science.gov (United States)

    Peterseim, M Millicent W; Rhodes, Ryan S; Patel, Rupa N; Wilson, M Edward; Edmondson, Luke E; Logan, Sarah A; Cheeseman, Edward W; Shortridge, Emily; Trivedi, Rupal H

    2018-03-01

    The GoCheck Kids smartphone photoscreening app (Gobiquity Mobile Health, Scottsdale, Arizona, USA), introduced in 2014, is marketed to pediatricians with little published validation. We wished to evaluate the GoCheck Kids Screener for accuracy in detecting amblyopia risk factors (ARF) using 2013 American Association for Pediatric Ophthalmology and Strabismus guidelines. Validity assessment. Children 6 months to 6 years of age presenting from October 2016 to August 2017 were included. Children were screened with the GoCheck preloaded Nokia Lumia 1020, software version 4.6 with image processing version R4d, prior to undergoing a comprehensive eye examination by a pediatric ophthalmologist masked to the screener results. Determination of the presence of age-specific ARF was made based upon the examination and compared with the GoCheck recommendation. A total of 206 children were included (average age 43 months). When compared to examination, GoCheck had a sensitivity of 76.0% and specificity of 67.2% in detecting ARF. Positive predictive value was 57.0% and negative predictive value 83.0%. The screener results of 13 children were changed from "no risk factors" to "risk factors identified" based on the GoCheck remote review process. Four images remained "not gradable" and screening was unsuccessful in 3 children. In our high-risk population, this version of the Gocheck Kids smartphone app was useful in identifying ARF in children who are often not able to cooperate with visual acuity testing. This study informs pediatricians about the efficacy of this new screener as they make decisions about how to best detect vision problems in young children. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Optimized Min-Sum Decoding Algorithm for Low Density Parity Check Codes

    OpenAIRE

    Mohammad Rakibul Islam; Dewan Siam Shafiullah; Muhammad Mostafa Amir Faisal; Imran Rahman

    2011-01-01

    Low Density Parity Check (LDPC) code approaches Shannon–limit performance for binary field and long code lengths. However, performance of binary LDPC code is degraded when the code word length is small. An optimized min-sum algorithm for LDPC code is proposed in this paper. In this algorithm unlike other decoding methods, an optimization factor has been introduced in both check node and bit node of the Min-sum algorithm. The optimization factor is obtained before decoding program, and the sam...