WorldWideScience

Sample records for saarberg-holter process

  1. ECG Holter monitor with alert system and mobile application

    Science.gov (United States)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  2. Smart blood pressure holter.

    Science.gov (United States)

    İlhan, İlhan

    2018-03-01

    In this study, a wireless blood pressure holter that can be used with smart mobile devices was developed. The developed blood pressure holter consists of two parts, which are a smart mobile device and a cuff. The smart mobile device is used as a recording, control and display device through a developed interface, while the cuff was designed to take measurements from the arm. Resistor-Capacitor (RC) and digital filters were used on the cuff that communicates with the smart mobile device via Bluetooth. The blood pressure was estimated using the Simple Hill Climbing Algorithm (HCA). It is possible to measure instantaneous or programmable blood pressure and heart rate values at certain intervals using this holter. The test was conducted with 30 individuals at different ages with the guidance of a specialist health personnel. The results showed that an accuracy at 93.89% and 91.95% rates could be obtained for systolic and diastolic pressure values, respectively, when compared with those obtained using a traditional sphygmomanometer. The accuracy level for the heart rate was measured as 97.66%. Furthermore, this device was tested day and night in the holter mode in terms of working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The test results were evaluated separately in terms of measurement accuracy, working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The measurement accuracy for systolic, diastolic blood pressure and heart rate values was obtained as 93.89%, 91.95% and 97.66%, respectively. The maximum number of measurements which can be conducted with four 1000 mA alkaline batteries at 20 min intervals was found approximately 79 (little more than 24 h). In addition, it was determined that the continuity of the Bluetooth connection and the reliability of the measurement results were automatically achieved through the features in the interface developed for the

  3. Holter registers and metabolic syndrome

    Science.gov (United States)

    Muñoz-Diosdado, A.; Ramírez-Hernández, L.; Aguilar-Molina, A. M.; Zamora-Justo, J. A.; Gutiérrez-Calleja, R. A.; Virgilio-González, C. D.

    2014-11-01

    There is a relationship between the state of the cardiovascular system and metabolic syndrome (MS). A way to diagnose the heart state of a person is to monitor the electrical activity of the heart using a 24 hours Holter monitor. Scanned ECG signal can be analyzed beat-by-beat by algorithms that separate normal of abnormal heartbeats. If the percentage of abnormal heartbeats is too high it could be argued that the patient has heart problems. We have algorithms that can not only identify the abnormal heartbeats, but they can also classify them, so we classified and counted abnormal heartbeats in patients with MS and subjects without MS. Most of our patients have large waist circumference, high triglycerides and high levels of LDL (high-density lipoprotein) cholesterol although some of them have high blood pressure. We enrolled adult patients with MS free of diabetes in a four month lifestyle intervention program including diet and physical aerobic exercise, and compared with healthy controls. We made an initial registration with a Holter, and 24 hours ECG signal is analyzed to identify and classify the different types of heartbeats. The patients then begin with diet or exercise (at least half an hour daily). Periodically Holter records were taken up and we describe the evolution in time of the number and type of abnormal heartbeats. Results show that the percentage of abnormal heartbeats decreases over time, in some cases the decline is very significant, and almost a reduction to half or less of abnormal heartbeats after several months since the patients changed their eating or physical activity habits.

  4. NORMAN HOLTER AND HIS METHOD OF REMOTE CARDIOLOGIC MONITORING. CASE HISTORY

    Directory of Open Access Journals (Sweden)

    A. A. Rassadina

    2013-01-01

    Full Text Available This publication is devoted to the personality and creative designs of uncommon American scientist, the engineer and the inventor – Norman Jefferis «Jeff» Holter. Norman Jefferis Holter introduced the terminology of «nuclear medicine» for the name of the new at that time area which associated with employment of the achievements of the nuclear physics in the medical goals. Also he is the author of ambulatory cardiological monitoring.

  5. Saarbergwerke AG. Report on the business year 1995; Saarbergwerke AG. Bericht ueber das Geschaeftsjahr 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-12-31

    The business report 1995 contains informations about the position of the energy economics, the position of the Saarberg trust and the yearly balance. The activities of the Saarberg trust are reported. (RHM) [Deutsch] Der Geschaeftsbericht 1995 enthaelt Ausfuehrungen ueber die Lage der Energiewirtschaft, die Lage des Saarberg-Konzerns und den Jahresabschluss. Die Aktivitaeten des Saarberg-Konzerns werden dargestellt. (RHM)

  6. Relationship between 24- hour Holter variables, chest discomfort and syncope: Does age matter?

    Directory of Open Access Journals (Sweden)

    Samir Kanti Saha

    2013-01-01

    Full Text Available One hundred and forty four ambulatory, non-emergent human subjects from 20-88 years of age were investigated following routine 24 hour Holter monitoring referred by primary and tertiary care centers primarily for evaluation of palpitations and syncope. The patients were grouped into 3 different age categories: A 20-59 years of age (16%, B 60-69 years of age (26.4% and C > 70 years of age (57.6%. Heart rate profile, RR intervals, symptoms, frequency of premature supra ventricular and ventricular complexes were registered. The data show that though the occurrence and frequency of premature atrial and ventricular contractions over a period of 24 hours did not differ between the groups, the younger subjects documented more subjective discomforts during the Holter monitoring. Extra-systoles in excess of 1000 beats / 24 hour occured incessantly throughout the registration. Patients with syncope and those without did not differ as regards the Holter variables. However, subjects with atrial fibrillation had acceptable rate control and had significantly lower incidence of syncope than those with sinus rhythm. The findings suggest that in a county setting, Holter monitoring for evaluation of syncope may not be the first hand mode of investigation in a non emergent setting. On the contrary, the modality appears to be valuable for monitoring patients with atrial fibrillation. Even mild symptoms in the elderly population may warrant closer clinical follow up to prevent cardiac events and/or syncope leading to serious physical injury.

  7. Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.

    Science.gov (United States)

    Rizos, Timolaos; Güntner, Janina; Jenetzky, Ekkehart; Marquardt, Lars; Reichardt, Christine; Becker, Rüdiger; Reinhardt, Roland; Hepp, Thomas; Kirchhof, Paulus; Aleynichenko, Elena; Ringleb, Peter; Hacke, Werner; Veltkamp, Roland

    2012-10-01

    Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxAF detection. Patients with acute ischemic stroke or transient ischemic attack were prospectively enrolled. After a 12-channel ECG on admission, all patients received 24-hour Holter ECG and CEM. Additionally, ECG monitoring data underwent automated analysis using dedicated software to identify pxAF. Patients with a history of atrial fibrillation or with atrial fibrillation on the admission ECG were excluded. Four hundred ninety-six patients (median age, 69 years; 61.5% male) fulfilled all inclusion criteria (ischemic stroke: 80.4%; transient ischemic attack: 19.6%). Median stroke unit stay lasted 88.8 hours (interquartile range, 65.0-122.0). ECG data for automated CEM analysis were available for a median time of 64.0 hours (43.0-89.8). Paroxysmal AF was documented in 41 of 496 patients (8.3%). Of these, Holter detected pxAF in 34.1%; CEM in 65.9%; and automated CEM in 92.7%. CEM and automated CEM detected significantly more patients with pxAF than Holter (Pstroke on stroke units compared with 24-hour Holter ECG. The comparative usefulness of prolonged or repetitive Holter ECG recordings requires further evaluation.

  8. 24-Hour Holter Monitoring at the Lagos State University Teaching ...

    African Journals Online (AJOL)

    However, only a minority of such patients have documented and confirmed clinically significant tachyarrhythmias in this study. A subsequent larger prospective study would shed more light on this subject. Key Words: Electrocardiogram (ECG), 24-hour Holter, Heart Rate variability. Paroxysmal tachyarrhythmias.

  9. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs.

    Directory of Open Access Journals (Sweden)

    Emily C Hodkinson

    2016-04-01

    Full Text Available INTRODUCTIONThe resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters.METHODS and RESULTSHolter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modelling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters.CONCLUSIONSHere we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic – environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease.

  10. Design of a Holter for Electroencephalography and Polysomnography

    International Nuclear Information System (INIS)

    Martin Gonzalez, Francisco; Velarde Reyes, Ernesto

    2009-01-01

    This paper presents the design of a 40 digital channels Holter for ambulatory studies of electroencephalography(EEG) and polisomnography (PSG), specially for epilepsy and sleep disorders. It includes a revision of the market and technologies used in such equipment. The requirements of design are established, and solutions are presented. It shows a functional diagram of the system including technologies like wireless communication, reading and writing in USB flash devices and a new amplifier design with dynamic compensation of direct current polarization

  11. Atrial fibrillation detected by external loop recording for seven days or two-day simultaneous Holter recording: A comparison in patients with ischemic stroke or transient ischemic attack.

    Science.gov (United States)

    Sejr, Michala Herskind; Nielsen, Jens Cosedis; Damgaard, Dorte; Sandal, Birgitte Forsom; May, Ole

    Atrial fibrillation (AF) is the most common cardiac cause of ischemic stroke and transient ischemic attack (IS/TIA). To compare the diagnostic value of seven-day external loop recording (ELR) and two-day Holter recording for detecting AF after IS/TIA. 191 IS/TIA patients without AF history. Endpoint was AF >30s. We started two-day Holter recording and seven-day ELR simultaneously. Seven-day ELR and two-day Holter recording detected the same three AF patients. ELR detected another six patients with AF adjudicated by cardiologists, four detections after Holter (3 vs. 7, p=0.125) and two false-positive detections during Holter. Seven-day ELR automatically classified 50/191 patients (26%) with AF, but only 7/50 (14%) were confirmed as AF by cardiologists. Seven-day ELR did not detect significantly more patients with AF than two-day Holter recording. 86% of patients with ELR-classified AF were false positives, indicating a poor performance of the automatic AF detection algorithm used. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Saarbergwerke AG. Business report 1993

    International Nuclear Information System (INIS)

    1994-01-01

    This report discusses the situation of energy economics, the situation of the Saarberg Group, and the energy and pollution abatement activities of the Saarberg Group. The annual financial statements and the statement of earnings are compiled. (HS) [de

  13. The relationship between ST segment deviation projected to the front of the chest during exercise and simultaneous Holter monitoring

    DEFF Research Database (Denmark)

    Egstrup, K

    1988-01-01

    were placed to correspond to CM5 and an aVF-like lead. In 36 patients, ST segment changes were found with both Holter and the 12-lead precordial electrocardiogram, while in 12 patients no ischaemic changes were detected by either method. Thus the results of the two methods concurred in 48 of 50 patient...... (96%). The magnitude of the ischaemic change was similar in 24 of 36 patients (67%), while the Holter system underestimated the ischaemic change by 0.5-2.0 mm in 12 patients. When the maximal ST segment deviation in V5 was compared with CM5, the deviations with both systems were identical in all...... but one patient in whom a difference of 0.5 mm was found. The use of a Holter lead resembling a VF identified maximal ST segment change on only one occasion, and in only four patients was an ST segment change of 1 mm noted. In conclusion, ambulatory monitoring utilizing only CM5 seems to detect most...

  14. Avaliação perioperatória através do holter em pacientes idosos submetidos à prostatectomia Evaluación perioperatoria mediante el holter en pacientes adultos mayores sometidos a prostatectomia Peri-operative evaluation by holter in elderly patients submitted to prostatectomy

    Directory of Open Access Journals (Sweden)

    Thais Orrico de Brito Cançado

    2009-10-01

    Full Text Available FUNDAMENTO: Em pacientes do sexo masculino, com idade acima de 65 anos e sem história de cardiopatia, faz-se necessário, assim como exames de avaliação pré-operatória, hemograma, eletrocardiograma e raios X do tórax. OBJETIVO: Tivemos como objetivo verificar se, nesses pacientes, estariam presentes alterações isquêmicas e no ritmo cardíaco, bem como o impacto do procedimento anestésico. Visamos, também, a verificar a validade da monitorização ambulatorial contínua como exame de avaliação pré-operatória nessa população, o qual não foi recomendado pelas atuais diretrizes. MÉTODOS: Utilizamos, neste protocolo, a monitorização ambulatorial contínua (Sistema Holter no período perioperatório de 30 pacientes com idade superior a 65 anos, os quais foram submetidos à ressecção transuretral de próstata sob raquianestesia. RESULTADOS: Encontramos nas avaliações pré-operatória e transoperatória frequentes arritmias ventriculares e supraventriculares complexas, bem como alterações isquêmicas. Na gravação transoperatória, os pacientes que apresentaram episódios isquêmicos foram os mesmos que, na gravação pré-operatória, mostraram carga isquêmica total maior do que 60 minutos. CONCLUSÃO: Aceitamos que a monitorização ambulatorial não seja um procedimento adequado para o screening da isquemia miocárdica, pelas próprias características e limitações técnicas que envolvem o método, principalmente quando são considerados grupos populacionais com baixa prevalência da doença coronariana. Concluímos que, neste estudo transverso e observacional, obtivemos informações complementares com o holter, as quais não puderam ser obtidas pelo eletrocardiograma convencional.FUNDAMENTO: En pacientes del sexo masculino, con edad superior a 65 años y sin historia de cardiopatía, se necesitan exámenes de evaluación preoperatoria, así como hemograma, electrocardiograma y rayos X de tórax. OBJETIVO: Tuvimos como

  15. Evaluation of the indications and arrhythmic patterns of 24 hour Holter electrocardiography among hypertensive and diabetic patients seen at OAUTHC, Ile-Ife Nigeria

    Directory of Open Access Journals (Sweden)

    Adebayo RA

    2014-11-01

    Full Text Available Rasaaq A Adebayo,1 Amanze N Ikwu,1 Michael O Balogun,1 Anthony O Akintomide,1 Tuoyo O Mene-Afejuku,1 Victor O Adeyeye,1 Olaniyi J Bamikole,1 Luqman A Bisiriyu,2 Olufemi E Ajayi,1 Suraj A Ogunyemi,1 Omolola A Oketona1 1Cardiology Unit, Department of Medicine, Obafemi Awolowo University Teaching Hospitals Complex, 2Department of Demography and Social Statistics, Obafemi Awolowo University, Ile-Ife, Osun State, Nigeria Background: There are very limited published studies in Nigeria on the use of 24 hour Holter electrocardiogram (Holter ECG in the arrhythmic evaluation of hypertensive and diabetic patients. Objective: To evaluate indications, arrhythmic pattern of Holter ECG, and heart rate variability (HRV among patients with hypertensive heart disease (HHD with or without heart failure and type 2 diabetes mellitus (T2DM seen in our cardiac care unit. Methods: Seventy-nine patients (32 males and 47 females were studied consecutively over a year using Schiller type (MT-101 Holter ECG machine. Results: Out of the 79 patients, 17 (21.5% had HHD without heart failure, 33 (41.8% had HHD with hypertensive heart failure (HHF, while 29 (36.7% were T2DM patients. The mean (standard deviation ages of HHD without heart failure, HHF and T2DM patients were 59.65 (±14.38, 65.15 (±14.30, and 54.66 (±8.88 respectively. The commonest indication for Holter ECG was palpitation (38%, followed by syncope (20.3%. Premature ventricular contraction was the commonest arrhythmic pattern among the 79 patients, especially among HHF patients. The HRV, using standard deviation of all normal-normal intervals was significantly reduced in T2DM patients (81.03±26.33, confidence interval [CI] =71.02–91.05 compared to the HHD without heart failure (119.65±29.86, CI =104.30–135.00 and HHF (107.03±62.50, CI =84.00–129.19. There was a negative correlation between the duration of T2DM and HRV (r=−0.613. Conclusion: Palpitation was the commonest Holter ECG indication and

  16. [Atypical sinus node dysfunction. Usefulness of implantable Holter. A case report].

    Science.gov (United States)

    Martí Almor, J; Delclòs Urgell, J; Bruguera Cortada, J

    2001-12-01

    We present an 84 year-old female patient with repeated syncopes/presyncopes in the last nine years. All diagnosis tests were negative, including ECG, 24-hour Holter, tilt table test and EP study. Therefore, a subcutaneous insertable loop recorder was implanted (Reveal). The recording of three episodes showed the association of presyncope with the onset of atrial fibrilation and, in two syncopes, with an atrial pause between AF episodes. Probably an abnormal prolonged sinus node recovery time (more than 6 s) allowed AF to restart before the sinus rhythm.

  17. Predictive value of casual ECG-based resting heart rate compared with resting heart rate obtained from Holter recording

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Dixen, Ulrik; Marott, Jacob L

    2014-01-01

    BACKGROUND: Elevated resting heart rate (RHR) is associated with cardiovascular mortality and morbidity. Assessment of heart rate (HR) from Holter recording may afford a more precise estimate of the effect of RHR on cardiovascular risk, as compared to casual RHR. Comparative analysis was carried ...

  18. Development of an algorithm for heartbeats detection and classification in Holter records based on temporal and morphological features

    International Nuclear Information System (INIS)

    García, A; Romano, H; Laciar, E; Correa, R

    2011-01-01

    In this work a detection and classification algorithm for heartbeats analysis in Holter records was developed. First, a QRS complexes detector was implemented and their temporal and morphological characteristics were extracted. A vector was built with these features; this vector is the input of the classification module, based on discriminant analysis. The beats were classified in three groups: Premature Ventricular Contraction beat (PVC), Atrial Premature Contraction beat (APC) and Normal Beat (NB). These beat categories represent the most important groups of commercial Holter systems. The developed algorithms were evaluated in 76 ECG records of two validated open-access databases 'arrhythmias MIT BIH database' and M IT BIH supraventricular arrhythmias database . A total of 166343 beats were detected and analyzed, where the QRS detection algorithm provides a sensitivity of 99.69 % and a positive predictive value of 99.84 %. The classification stage gives sensitivities of 97.17% for NB, 97.67% for PCV and 92.78% for APC.

  19. A portable ECG monitoring device with Bluetooth and Holter capabilities for telemedicine applications.

    Science.gov (United States)

    Lucani, Daniel; Cataldo, Giancarlos; Cruz, Julio; Villegas, Guillermo; Wong, Sara

    2006-01-01

    A prototype of a portable ECG-monitoring device has been developed for clinical and non-clinical environments as part of a telemedicine system to provide remote and continuous surveillance of patients. The device can acquire, store and/or transmit ECG signals to computer-based platforms or specially configured access points (AP) with Intranet/Internet capabilities in order to reach remote monitoring stations. Acquired data can be stored in a flash memory card in FAT16 format for later recovery, or transmitted via Bluetooth or USB to a local station or AP. This data acquisition module (DAM) operates in two modes: Holter and on-line transmission.

  20. Circadian variation in QT dispersion determined from a 12-lead Holter recording

    DEFF Research Database (Denmark)

    Hansen, Stig; Rasmussen, Verner; Larsen, Klaus

    2007-01-01

    Background: QT dispersion is considered to reflect inhomogeneity of myocardial repolarization. Method: The circadian variation of QT interval dispersion was examined in 95 healthy subjects using 24-hour Holter monitoring. Three different methods of lead selection were applied: all 12 leads (QTdisp...... circadian variation using mean values of QTdisp 12, QTdisp 6, or QTdisp 2 obtained every hour, every 2, or every 4 hours, except in QTdisp 6, which demonstrated a significant circadian variation (P ... a significant circadian variation in QTdisp 12 and QTdisp 6 (P circadian variation was seen in QTdisp 2. A subdivision into 10-year age groups revealed that subjects at age >50 years had a significant circadian variation in QTdisp 12 and QTdisp 6, but not in QTdisp 2. Only in males...

  1. Holter con memorias SD y sistema experto de evaluación cardíaca

    OpenAIRE

    Pfarher, Iván; Reula, Germán; Tovorosky, Pablo; Zanin, Miguel; Caballero, Raúl M.; Maggiolo, Gustavo Daniel

    2006-01-01

    Este desarrollo se enmarca dentro de las actividades de la cátedra de Técnicas Digitales de Ingeniería en Electrónica en UTN-FRP y tiene como objeto potenciar la capacidad de diseño de los alumnos. En este caso se ha desarrollado un sistema holter utilizando memorias SD comunes en el mercado de las cámaras fotográficas implementando además un sistema ordenador de control a partir del uso de un microcontrolador con el sistema de operación y de captura embebido correspondiente para la captura, ...

  2. Characteristics and prognostic importance of ST-segment elevation on Holter monitoring early after acute myocardial infarction

    DEFF Research Database (Denmark)

    Mickley, H; Nielsen, J R; Berning, J

    1995-01-01

    The correlation between episodes of ST-segment elevation on Holter monitoring, clinical characteristics, left ventricular function, exercise testing, and long-term prognosis was determined in 123 consecutive patients 55 +/- 8 years old (mean +/- SD) with a first acute myocardial infarction (AMI...... +/- 11% (p = 0.0001). All episodes of ST-segment elevation were asymptomatic and did not correlate with different indicators of myocardial ischemia. Indeed, exercise-induced ST-segment depression was more prevalent in group 2 than in group 1: 57 vs 18% (p

  3. Psicologia aplicada à cardiologia: um estudo sobre emoções relatadas em exame de holter

    OpenAIRE

    Bonomo, Ana Myriam Sánchez; Araujo, Tereza Cristina Cavalcanti Ferreira de

    2009-01-01

    Estudos sobre fatores de risco associados a doenças do coração dão ênfase às emoções negativas e não esclarecem quanto aos efeitos cardíacos de vivências de alegria ou segurança. Realizou-se uma investigação com 30 pessoas submetidas ao exame de Holter 24 horas, visando identificar emoções e episódios de vida diária que ocorrem simultaneamente a arritmias cardíacas. Reuniram-se registros de arritmias, atividades e emoções, complementados por entrevistas semiestruturadas. Verificaram-se difere...

  4. Serial Holter ST-segment monitoring after first acute myocardial infarction. Prevalence, variability, and long-term prognostic importance of transient myocardial ischemia

    DEFF Research Database (Denmark)

    Mickley, H; Nielsen, J R; Berning, J

    1998-01-01

    Based on serial Holter monitoring performed 7 times within 3 years after a first acute myocardial infarction, we assessed the prevalence, variability and long-term clinical importance of transient myocardial ischemia (TMI) defined as episodes of ambulatory ST-segment depression. In all, 121...... consecutive male patients variability was found within and between patients...

  5. Holter-electrocardiogram-monitoring in patients with acute ischaemic stroke (Find-AFRANDOMISED): an open-label randomised controlled trial.

    Science.gov (United States)

    Wachter, Rolf; Gröschel, Klaus; Gelbrich, Götz; Hamann, Gerhard F; Kermer, Pawel; Liman, Jan; Seegers, Joachim; Wasser, Katrin; Schulte, Anna; Jürries, Falko; Messerschmid, Anna; Behnke, Nico; Gröschel, Sonja; Uphaus, Timo; Grings, Anne; Ibis, Tugba; Klimpe, Sven; Wagner-Heck, Michaela; Arnold, Magdalena; Protsenko, Evgeny; Heuschmann, Peter U; Conen, David; Weber-Krüger, Mark

    2017-04-01

    Atrial fibrillation is a major risk factor for recurrent ischaemic stroke, but often remains undiagnosed in patients who have had an acute ischaemic stroke. Enhanced and prolonged Holter-electrocardiogram-monitoring might increase detection of atrial fibrillation. We therefore investigated whether enhanced and prolonged rhythm monitoring was better for detection of atrial fibrillation than standard care procedures in patients with acute ischaemic stroke. Find-AF randomised is an open-label randomised study done at four centres in Germany. We recruited patients with acute ischaemic stroke (symptoms for 7 days or less) aged 60 years or older presenting with sinus rhythm and without history of atrial fibrillation. Patients were included irrespective of the suspected cause of stroke, unless they had a severe ipsilateral carotid or intracranial artery stenosis, which were the exclusion criteria. We used a computer-generated allocation sequence to randomly assign patients in a 1:1 ratio with permuted block sizes of 2, 4, 6, and 8, stratified by centre, to enhanced and prolonged monitoring (ie, 10-day Holter-electrocardiogram [ECG]-monitoring at baseline, and at 3 months and 6 months of follow-up) or standard care procedures (ie, at least 24 h of rhythm monitoring). Participants and study physicians were not masked to group assignment, but the expert committees that adjudicated endpoints were. The primary endpoint was the occurrence of atrial fibrillation or atrial flutter (30 sec or longer) within 6 months after randomisation and before stroke recurrence. Because Holter ECG is a widely used procedure and not known to harm patients, we chose not to assess safety in detail. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01855035. Between May 8, 2013, and Aug 31, 2014, we recruited 398 patients. 200 patients were randomly assigned to the enhanced and prolonged monitoring group and 198 to the standard care group. After 6

  6. Prognosis in medically stabilized unstable angina: Early Holter ST-segment monitoring compared with predischarge exercise thallium tomography

    International Nuclear Information System (INIS)

    Marmur, J.D.; Freeman, M.R.; Langer, A.; Armstrong, P.W.

    1990-01-01

    The objective of this study was to assess the relative value of invasive and noninvasive predictors of outcome in patients after unstable angina. Fifty-four patients with unstable angina who had 6-month follow-up after stabilization on medical therapy were evaluated. We prospectively compared 24-hour Holter ST-segment monitoring at admission, quantitative exercise thallium tomography, and cardiac catheterization 5 +/- 2 days after admission and analyzed their value for predicting a cardiac event in patients with unstable angina within 6 months. When patients with a favorable outcome (n = 40) were compared with patients with an unfavorable outcome (n = 11) no statistical difference was found in duration of ST shift of 1 mm or more on Holter monitoring (51 +/- 119 min compared with 37 +/- 43 min), exercise duration by the standard Bruce protocol (8.0 +/- 3.6 min compared with 7.9 +/- 3.1 min), exercise-induced ST depression (0.6 +/- 0.9 mm compared with 1.0 +/- 1.0 mm), and contrast left ventricular ejection fraction (70% +/- 10% compared with 69% +/- 15%). Patients with a favorable outcome were distinguished from those with an unfavorable outcome by a higher maximum rate-pressure product (24 x 10(3) +/- 6 x 10(3) compared with 18 x 10(3) +/- 7 x 10(3), P = 0.0025), smaller size of the reversible scintigraphic perfusion defect expressed as a percentage of total myocardium imaged (6% +/- 11% compared with 17% +/- 18%, P = 0.05) and a smaller number of vessels with stenosis of 50% or more (1.1 +/- 1.2 compared with 2.1 +/- 1.0, P = 0.01). On multiple logistic regression analysis, a history of previous myocardial infarction was the most powerful predictor of outcome. In patients without myocardial infarction, reversible exercise thallium perfusion defect size was the only predictor

  7. Milliken Station Demonstration Project FDG retrofit update

    Energy Technology Data Exchange (ETDEWEB)

    Alder, R.C.; Jackson, C.E.; O`Dea, D.T. [and others

    1994-12-31

    The Milliken Clean Coal Demonstration Project is one of the nine Clean Coal Projects selected for funding in Round 4 of the U.S. DOE`s Clean Coal Demonstration Program. The project`s sponsor is New York State Electric and Gas Corporation (NYSEG). Project team members include CONSOL Inc., Saarberg-Holter-Umwelttechnik (SHU), NALCO/FuelTech, Stebbins Engineering and Manufacturing Co., DHR Technologies, and CE Air Preheater. Gilbert/Commonwealth is the Architect/Engineer and Construction Manager for the flue gas desulfurization (FGD) retrofit. The project will provide full-scale demonstration of a combination of innovative emission-reducing technologies and plant upgraded for the control of sulfur dioxide (SO{sub 2}) and nitrogen oxides (NO{sub x}) emissions from a coal-fired steam generator without a significant loss of station efficiency. The overall project goals are the following: 98% SO{sub 2} removal efficiency using limestone while burning high sulfur coal; up to 70% NO{sub x} reduction using the NOXOUT selective non-catalytic reduction (SNCR) technology in conjunction with combustion modifications; minimization of solid waste by producing marketable by-products including commercial grade gypsum, calcium chloride, and fly ash; zero wastewater discharge; maintenance of station efficiency by using a high efficiency heat-pipe air heater system and a low-power-consuming scrubber system. The demonstration project is being conducted at NYSEG`s Milliken Station, located in Lansing, New York. Milliken Station has two 150-MWe pulverized coal-fired units built in the 1950s by Combustion Engineering. The SHU FGD process and the combustion modifications are being installed on both units, but the NOXOUT process, Plant Economic Optimization Advisor (PEOA), and the high-efficiency air heater system will be installed on only one unit.

  8. Recomendações da sociedade brasileira de arritmias cardíacas para serviços de holter

    Directory of Open Access Journals (Sweden)

    Adalberto Lorga Filho

    2013-08-01

    Full Text Available FUNDAMENTOS: Inúmeros indicadores são utilizados para assegurar a qualidade de um serviço; entretanto, a competência médica e o adequado fluxo de realização de um procedimento são determinantes da qualidade final. Nesse contexto, a Sociedade Brasileira de Arritmias Cardíacas pretende recomendar parâmetros mínimos necessários para garantir a excelência dos serviços de monitorização eletrocardiográfica ambulatorial. OBJETIVOS: Recomendar competências médicas mínimas e as informações necessárias para emissão do laudo de Holter. MÉTODOS: O documento foi fundamentado no conceito de medicina baseada em evidência, e nas circunstâncias em que a evidência não estava disponível a opinião de uma comissão de redação foi utilizada para a formulação da recomendação. Essa comissão foi formada por profissionais que apresentam vivência nas dificuldades do método e gestão na prestação de serviços nessa área. RESULTADOS: O profissional responsável pela análise de Holter deve conhecer as patologias cardiovasculares e ter formação consistente em eletrocardiografia, incluindo arritmias cardíacas e seus diagnósticos diferenciais. O laudo deve ser redigido de forma clara e objetiva. Os parâmetros mínimos que devem constar no laudo incluem as estatísticas do exame, assim como quantificação e análise dos distúrbios do ritmo observados durante a monitorização. CONCLUSÃO: A monitorização eletrocardiográfica ambulatorial deve ser realizada por profissionais com vivência em análise eletrocardiográfica e o laudo deve conter os parâmetros mínimos mencionados nesse documento.

  9. Psicologia aplicada à cardiologia: um estudo sobre emoções relatadas em exame de holter

    Directory of Open Access Journals (Sweden)

    Ana Myriam Sánchez Bonomo

    Full Text Available Estudos sobre fatores de risco associados a doenças do coração dão ênfase às emoções negativas e não esclarecem quanto aos efeitos cardíacos de vivências de alegria ou segurança. Realizou-se uma investigação com 30 pessoas submetidas ao exame de Holter 24 horas, visando identificar emoções e episódios de vida diária que ocorrem simultaneamente a arritmias cardíacas. Reuniram-se registros de arritmias, atividades e emoções, complementados por entrevistas semiestruturadas. Verificaram-se diferenças acentuadas entre gêneros: mulheres apresentaram mais arritmias que homens. Nas mulheres, arritmias ventriculares ocorreram mais simultaneamente à preocupação do que à ansiedade e não se mostraram relacionadas à raiva. A tristeza não foi associada a arritmias ventriculares por nenhum dos gêneros.

  10. Finding atrial fibrillation in stroke patients: Randomized evaluation of enhanced and prolonged Holter monitoring--Find-AF(RANDOMISED) --rationale and design.

    Science.gov (United States)

    Weber-Krüger, Mark; Gelbrich, Götz; Stahrenberg, Raoul; Liman, Jan; Kermer, Pawel; Hamann, Gerhard F; Seegers, Joachim; Gröschel, Klaus; Wachter, Rolf

    2014-10-01

    Detecting paroxysmal atrial fibrillation (AF) in patients with ischemic strokes presenting in sinus rhythm is challenging because episodes are often short, occur randomly, and are frequently asymptomatic. If AF is detected, recurrent thromboembolism can be prevented efficiently by oral anticoagulation. Numerous uncontrolled studies using various electrocardiogram (ECG) devices have established that prolonged ECG monitoring increases the yield of AF detection, but most established procedures are time-consuming and costly. The few randomized trials are mostly limited to cryptogenic strokes. The optimal method, duration, and patient selection remain unclear. Repeated prolonged continuous Holter ECG monitoring to detect paroxysmal AF within an unspecific stroke population may prove to be a widely applicable, effective secondary prevention strategy. Find-AFRANDOMISED is a randomized and controlled prospective multicenter trial. Four hundred patients 60 years or older with manifest (symptoms ≥24 hours or acute computed tomography/magnetic resonance imaging lesion) and acute (symptoms ≤7 days) ischemic strokes will be included at 4 certified stroke centers in Germany. Those with previously diagnosed AF/flutter, indications/contraindications for oral anticoagulation, or obvious causative blood vessel pathologies will be excluded. Patients will be randomized 1:1 to either enhanced and prolonged Holter ECG monitoring (10 days at baseline and after 3 and 6 months) or standard of care (≥24-hour continuous ECG monitoring, according to current stroke guidelines). All patients will be followed up for at least 12 months. The primary end point is newly detected AF (≥30 seconds) after 6 months, confirmed by an independent adjudication committee. We plan to complete recruitment in autumn 2014. First results can be expected by spring 2016. Copyright © 2014 Mosby, Inc. All rights reserved.

  11. Yield of atrial fibrillation detection with Textile Wearable Holter from the acute phase of stroke: Pilot study of Crypto-AF registry.

    Science.gov (United States)

    Pagola, Jorge; Juega, Jesus; Francisco-Pascual, Jaume; Moya, Angel; Sanchis, Mireia; Bustamante, Alejandro; Penalba, Anna; Usero, Maria; Cortijo, Elisa; Arenillas, Juan F; Calleja, Ana I; Sandin-Fuentes, Maria; Rubio, Jeronimo; Mancha, Fernando; Escudero-Martinez, Irene; Moniche, Francisco; de Torres, Reyes; Pérez-Sánchez, Soledad; González-Matos, Carlos E; Vega, Ángela; Pedrote, Alonso A; Arana-Rueda, Eduardo; Montaner, Joan; Molina, Carlos A

    2018-01-15

    We describe the feasibility of monitoring with a Textile Wearable Holter (TWH) in patients included in Crypto AF registry. We monitored cryptogenic stroke patients from stroke onset (<3days) continuously during 28days. We employed a TWH composed by a garment and a recorder. We compared two garments (Lead and Vest) to assess rate of undiagnosed Atrial Fibrillation (AF) detection, monitoring compliance, comfortability (1 to 5 points), skin lesions, and time analyzed. We describe the timing of AF detection in three periods (0-3, 4-15 and 16-28days). The rate of undiagnosed AF detection with TWH was 21.9% (32 out of 146 patients who completed the monitoring). Global time compliance was 90% of the time expected (583/644h). The level of comfortability was 4 points (IQR 3-5). We detected reversible skin lesions in 5.47% (8/146). The comfortability was similar but time compliance (in hours) was longer in Vest group 591 (IQR [521-639]) vs. Lead 566 (IQR [397-620]) (p=0.025). Also, time analyzed was more prolonged in Vest group 497 (IQR [419-557]) vs. Lead (336h (IQR [140-520]) (p=0.001)). The incidence of AF increases from 5.6% (at 3days) to 17.5% (at 15th day) and up to 20.9% (at 28th day). The percentage of AF episodes detected only in each period was 12.5% (0-3days); 21.7% (4-15days) and 19% (16-28days). 28days Holter monitoring from the acute phase of the stroke was feasible with TWH. Following our protocol, only five patients were needed to screen to detected one case of AF. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. 45. Ezetimibe and statins yields on silent holter ambulatory myocardial ischemia

    Directory of Open Access Journals (Sweden)

    W. Kadro

    2016-07-01

    Full Text Available Further cholestrol lowering may affect silent ischemia detected on holter monitoring. Cholesterol lowering is associated with a reduction in cardiovascular morbidity and mortality. Statins are the main drugs for cholesterol lowering. Ezetimibe when added to statins gives further reduction in cholesterol but its long-term effect on cardiovascular morbidity and mortality and ischemic events is not known. This study sought to determine whether further cholesterol lowering with ezitimibe will also results in a reduction of myocardial ischemia during daily life. We enrolled 50 patients with proven stable coronary artery disease (CAD and at least one episode of ST-segment depression on ambulatory ECG monitoring. All of them were receiving optimal therapy for CAD including statin therapy for cholesterol reduction. 25 patients were randomized to continue their statin therapy (Statin only group and 25 to recieve statin plus ezitimibe 10 mg/day (ezitimibe group. Serum cholesterol and LDL cholesterol levels and ambulatory monitoring were repeated after 4–6 months of therapy. The two groups were comparable with respect to baseline characteristics, number of episodes of ST-segment depression, and baseline serum cholesterol levels. The ezitimibe group had lower mean total and LDL cholesterol levels at study end and experienced a significant reduction in the number of episodes of ST-segment depression compared with the statin only group. ST-segment depression was completely resolved in 13 of 25 patients (52% in the ezitimibe group versus 3 of 25 (12% in the statin only group. The ezitimibe group exhibited a highly significant reduction in ambulatory ischemia (P < .001. By logistic regression, treatment with ezitimibe was an independent predictor of ischemia resolution. Further cholesterol lowering with ezitimibe can result in reduction or resolution of myocardial ischemia recorded as episodes of ST-segment depression in ambulatory monitoring of the ECG.

  13. QTc interval prolongation in HIV-infected patients: a case–control study by 24-hour Holter ECG recording

    Directory of Open Access Journals (Sweden)

    Fiorentini Alessandra

    2012-12-01

    Full Text Available Abstract Background Aim of the study was to assess QTc interval by a 24-hour ECG recording in a group of HIV-infected individuals with a basal prolonged QTc. The risk factors associated with QTc prolongation and the indices of cardiovascular autonomic control were also evaluated. Methods A case–control study was performed using as cases 32 HIV-infected patients with prolonged (>440 msec QTc interval as assessed by Holter ECG, and as controls 64 HIV-infected subjects with normal QTc interval. Autonomic function was evaluated by heart rate variability analysis during 24-hour recording. Results Duration of HIV disease was significantly longer among cases than among controls (p=0.04. Waist/hip ratio was also higher among cases than among controls (p=0.05. Frequency domain analysis showed the absence of physiologic decrease of low frequency (LF in the night period in both cases and controls. The LF night in cases showed a statistically significant reduction when compared with controls (p=0.007. Conclusions In our study group, QTc interval prolongation was associated with a longer duration of HIV infection and with a greater waist/hip ratio. HIV patients with QTc interval prolongation and with a longer duration of HIV infection were more likely to have an impairment of parasympathetic and sympathetic cardiac component.

  14. Saarbergwerke AG. Annual report 1992

    International Nuclear Information System (INIS)

    1993-01-01

    The business report contains informations about the position of the energy economics, the position of the Saarberg trust and the yearly balance. The activities in the field of energy comprise the production and scale of coal, the production of coke and electrical power and district heat. Furthermore it is reported about the trade of solid and liquid fuels, services in the engineering and environment technology and non-energy activities. (orig.) [de

  15. The Telemetric and Holter ECG Warehouse Initiative (THEW): a Data Repository for the Design, Implementation and Validation of ECG-related Technologies

    Science.gov (United States)

    Couderc, Jean-Philippe

    2011-01-01

    We present an initiative supported by the National Heart Lung, and Blood Institute and the Food and Drug Administration for the development of a repository containing continuous electrocardiographic information to be shared with the worldwide scientific community. We believe that sharing data reinforces open scientific inquiry. It encourages diversity of analysis and opinion while promoting new research and facilitating the education of new researchers. In this paper, we present the resources available in this initiative for the scientific community. We describe the set of ECG signals currently hosted and we briefly discuss the associated clinical information (medical history. Disease and study-specific endpoints) and software tools we propose. Currently, the repository contains more than 250GB of data from eight clinical studies including healthy individuals and cardiac patients. This data is available for the development, implementation and validation of technologies related to body-surface ECGs. To conclude, the Telemetric and Holter ECG Warehouse (THEW) is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. PMID:21097349

  16. Comparison of two systems for long-term heart rate variability monitoring in free-living conditions - a pilot study

    DEFF Research Database (Denmark)

    Kristiansen, Jesper; Korshoj, Mette; Skotte, Jorgen H

    2011-01-01

    Actiheart and Holter recorders, and signals were processed to RR-interval time series. Segments of 5-minute duration were sampled every 30 minutes, and spectral components of the heart rate variability were calculated. Actiheart and Holter values were compared using Deming regression analysis and Bland...

  17. A wearable smartphone-based platform for real-time cardiovascular disease detection via electrocardiogram processing.

    Science.gov (United States)

    Oresko, Joseph J; Duschl, Heather; Cheng, Allen C

    2010-05-01

    Cardiovascular disease (CVD) is the single leading cause of global mortality and is projected to remain so. Cardiac arrhythmia is a very common type of CVD and may indicate an increased risk of stroke or sudden cardiac death. The ECG is the most widely adopted clinical tool to diagnose and assess the risk of arrhythmia. ECGs measure and display the electrical activity of the heart from the body surface. During patients' hospital visits, however, arrhythmias may not be detected on standard resting ECG machines, since the condition may not be present at that moment in time. While Holter-based portable monitoring solutions offer 24-48 h ECG recording, they lack the capability of providing any real-time feedback for the thousands of heart beats they record, which must be tediously analyzed offline. In this paper, we seek to unite the portability of Holter monitors and the real-time processing capability of state-of-the-art resting ECG machines to provide an assistive diagnosis solution using smartphones. Specifically, we developed two smartphone-based wearable CVD-detection platforms capable of performing real-time ECG acquisition and display, feature extraction, and beat classification. Furthermore, the same statistical summaries available on resting ECG machines are provided.

  18. A Unique Digital Electrocardiographic Repository for the Development of Quantitative Electrocardiography and Cardiac Safety: The Telemetric and Holter ECG Warehouse (THEW)

    Science.gov (United States)

    Couderc, Jean-Philippe

    2010-01-01

    The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This information is shared with the worldwide scientific community in order to improve quantitative electrocardiology and cardiac safety. First, we present the objectives of the initiative and its mission. Then, we describe the resources available in this initiative following three components: data, expertise and tools. The Data available in the Telemetric and Holter ECG Warehouse (THEW) includes continuous ECG signals and associated clinical information. The initiative attracted various academic and private partners whom expertise covers a large list of research arenas related to quantitative electrocardiography; their contribution to the THEW promotes cross-fertilization of scientific knowledge, resources, and ideas that will advance the field of quantitative electrocardiography. Finally, the tools of the THEW include software and servers to access and review the data available in the repository. To conclude, the THEW is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. It is a new repository designed to complement the existing ones such as Physionet, the AHA-BIH Arrhythmia Database, and the CSE database. The THEW hosts unique datasets from clinical trials and drug safety studies that, so far, were not available to the worldwide scientific community. PMID:20863512

  19. The Implementation of IS on the Knowledge Management and Mental Models at the Decision-Making Process

    Science.gov (United States)

    2011-03-01

    results. Further attention to the use and refinement of fidelity criteria is important to the evaluation practice (Mowbray, Holter, Teague, & Bybee ...C., Teague, G. B., & Bybee , D. (2003). Fidelity Criteria: Development, Measurement, and Validation. American Journal of Evaluation, 24(3), 315–340

  20. Bedside identification of patients at risk for PVC-induced cardiomyopathy: Is ECG useful?

    Science.gov (United States)

    Garster, Noelle C; Henrikson, Charles A

    2017-07-01

    Premature ventricular complexes (PVCs) are an underrecognized cause of cardiomyopathy. Standard 12-lead electrocardiogram (ECG) has potential to direct attention toward at-risk patients. We performed a single-center, retrospective chart review of 1,240 patients who completed ECG and Holter monitoring at Oregon Health and Science University Hospital between January 1, 2011 and December 31, 2013 to investigate the relationship of PVC frequency on ECG with burden on Holter. Primary outcome measures included PVC quantity on ECG, mean PVC quantity on Holter, and percentage of total beats on Holter recorded as PVCs. High PVC burden was defined as ≥10% of total beats. Weighted mean percentages of total beats on Holter monitor recorded as PVCs were calculated for 0, 1, 2, and ≥3 PVCs on ECG and found to be 1.4% (n = 1,128), 3.5% (n = 32), 4.3% (n = 25), and 16.6% (n = 55), respectively, which represent statistically significant differences (P ECG for ≥10% PVC Holter burden was 58%. Negative predictive value for 0 PVCs on ECG was 98%. The sensitivity and specificity of ECG to identify high PVC burden on Holter was 72% and 93.6%, respectively, when utilizing a positive ECG result as one PVC or more, and 44% and 98.9%, respectively, with ≥3 PVCs on ECG. The positive likelihood ratio corresponding to ≥3 PVCs on ECG was 40. These findings demonstrate that the number of PVCs on ECG can be utilized for quick bedside estimation of high PVC burden. © 2017 Wiley Periodicals, Inc.

  1. The evolution of ambulatory ECG monitoring.

    Science.gov (United States)

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health. © 2013.

  2. ST-segment deviation during 24-hour ambulatory electrocardiographic monitoring and exercise stress test in healthy male subjects 51 to 75 years of age: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner; Sørum, C

    1999-01-01

    or descending ST-segment depression of >/=0.15 mV during Holter monitoring or at the exercise test, respectively. Furthermore, the specificity was 0.95 when a horizontal or downsloping ST-segment depression of 0.1 mV was displayed in both the Holter and exercise electrocardiographic recording system......BACKGROUND: Although ST-segment deviation has been evaluated and used during many years both on continuous electrocardiographic Holter monitoring and during exercise stress testing, considerable controversy still remains concerning the prevalence and diagnostic significance of fortuitously...... discovered ST-segment deviation in asymptomatic healthy persons. METHODS AND RESULTS: The occurrence of ST-segment deviation was studied in a population of 63 clinically healthy male subjects 51 to 75 years of age, with the use of 24-hour Holter monitoring and exercise stress testing. The subjects were...

  3. On the Beat Detection Performance in Long-Term ECG Monitoring Scenarios

    Directory of Open Access Journals (Sweden)

    Francisco-Manuel Melgarejo-Meseguer

    2018-05-01

    Full Text Available Despite the wide literature on R-wave detection algorithms for ECG Holter recordings, the long-term monitoring applications are bringing new requirements, and it is not clear that the existing methods can be straightforwardly used in those scenarios. Our aim in this work was twofold: First, we scrutinized the scope and limitations of existing methods for Holter monitoring when moving to long-term monitoring; Second, we proposed and benchmarked a beat detection method with adequate accuracy and usefulness in long-term scenarios. A longitudinal study was made with the most widely used waveform analysis algorithms, which allowed us to tune the free parameters of the required blocks, and a transversal study analyzed how these parameters change when moving to different databases. With all the above, the extension to long-term monitoring in a database of 7-day Holter monitoring was proposed and analyzed, by using an optimized simultaneous-multilead processing. We considered both own and public databases. In this new scenario, the noise-avoid mechanisms are more important due to the amount of noise that exists in these recordings, moreover, the computational efficiency is a key parameter in order to export the algorithm to the clinical practice. The method based on a Polling function outperformed the others in terms of accuracy and computational efficiency, yielding 99.48% sensitivity, 99.54% specificity, 99.69% positive predictive value, 99.46% accuracy, and 0.85% error for MIT-BIH arrhythmia database. We conclude that the method can be used in long-term Holter monitoring systems.

  4. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    Science.gov (United States)

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  5. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    Science.gov (United States)

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86Holter at rest, during 6MW and recovery. At higher rates, a small effect in increasing differences between Holter and Polar in R-R intervals was observed. In conclusion, our study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.

  6. Effects of atomoxetine on heart rhythm in children and adolescents.

    Science.gov (United States)

    Tanidir, Ibrahim Cansaran; Tanidir, Canan; Ozturk, Erkut; Bahali, Kayhan; Gunes, Hatice; Ergul, Yakup; Uneri, Ozden Sukran; Akdeniz, Celal; Tuzcu, Volkan

    2015-12-01

    The aim of this study was to examine the effects of atomoxetine on heart rhythm using 12-lead electrocardiography (ECG) and 24 h Holter monitoring. Children and adolescents who were diagnosed with attention deficit-hyperactivity disorder according to DSM-IV-TR were referred to a pediatric cardiology clinic for cardiologic examination before and after 4 or 5 weeks of atomoxetine treatment. Cardiac examination, complete blood count, biochemistry, thyroid function tests, 12-lead ECG and 24 h Holter monitoring were performed routinely in all patients. Each subject underwent 24 h Holter ECG monitoring before atomoxetine was started and after 4 or 5 weeks of effective dose atomoxetine treatment. Forty-one patients were included in this prospective study. No statistically significant change was found in QT, QTc or QT interval dispersion or blood pressure before and after 4 or 5 weeks of atomoxetine treatment. There was a statistically significant increase in heart rate (both during the day and at night) and QRS duration, and a statistically significant decrease in P wave dispersion. Three patients had rhythm disturbances. All of these three patients were asymptomatic and none of these arrhythmias reached clinical significance. Atomoxetine did not cause significant changes in ECG or Holter variables. In two patients, who had undiagnosed subclinical extrasystoles, extra beats were increased after 4th week of treatment, but still remained clinically insignificant. Before and after atomoxetine treatment, listening to the heart sounds for a longer time, may help clinicians to notice an extra beat. If an extra beat is identified then 24 Holter monitoring is recommended. © 2015 Japan Pediatric Society.

  7. Heart rate turbulence after ventricular premature beats in healthy Doberman pinschers and those with dilated cardiomyopathy.

    Science.gov (United States)

    Harris, J D; Little, C J L; Dennis, J M; Patteson, M W

    2017-10-01

    To describe the measurement of heart rate turbulence (HRT) after ventricular premature beats and compare HRT in healthy Doberman pinschers and those with dilated cardiomyopathy (DCM), with and without congestive heart failure (CHF). Sixty-five client-owned Dobermans: 20 healthy (NORMAL), 31 with preclinical DCM and 14 with DCM and CHF (DCM + CHF). A retrospective study of data retrieved from clinical records and ambulatory ECG (Holter) archives, including data collected previously for a large-scale prospective study of Dobermans with preclinical DCM. Holter data were reanalysed quantitatively, including conventional time-domain heart rate variability and the HRT parameters turbulence onset and turbulence slope. Heart rate turbulence could be measured in 58/65 dogs. Six Holter recordings had inadequate ventricular premature contractions (VPCs) and one exhibited VPCs too similar to sinus morphology. Heart rate turbulence parameter, turbulence onset, was significantly reduced in DCM dogs, whereas conventional heart rate variability measures were not. Heart rate variability and HRT markers were reduced in DCM + CHF dogs as expected. Heart rate turbulence can be measured from the majority of good quality standard canine 24-hour Holter recordings with >5 VPCs. Turbulence onset is significantly reduced in Dobermans with preclinical DCM which indicates vagal withdrawal early in the course of disease. Heart rate turbulence is a powerful prognostic indicator in human cardiac disease which can be measured from standard 24-hour ambulatory ECG (Holter) recordings using appropriate computer software. Further studies are warranted to assess whether HRT may be of prognostic value in dogs with preclinical DCM and in other canine cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. [Limits of cardiac functional adaptation in "top level" resistance athletes].

    Science.gov (United States)

    Carù, B; Righetti, G; Bossi, M; Gerosa, C; Gazzotti, G; Maranetto, D

    2001-02-01

    Sports activity, particularly when performed at high level, provokes cardiovascular adjustments depending on the type of sport and on the level of the load. We evaluated 15 athletes from the Italian national team during a non-agonistic period of cross country skiing, with non-invasive tests including exercise test, color Doppler echocardiography, Holter monitoring, physical examination and standard rest electrocardiogram. Physical examination, rest electrocardiogram, exercise testing and echocardiography were all within the range of the expected values for this type of subjects. Holter monitoring recorded during the periods of agonistic activity revealed significant hypokinetic arrhythmias such as severe bradycardia, pauses, I and II degree atrioventricular blocks, and complete atrioventricular block in 2 cases; these features were not observed on Holter monitoring recorded during the non-agonistic period. The perfect health status of subjects and their racing results may bring about physiological functional adjustments, but these observations suggest the need for a follow-up to evaluate possible pathologic outcomes.

  9. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    International Nuclear Information System (INIS)

    Braceli, Agustín Iriart; Morani, Jorge Exequiel

    2011-01-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  10. Design and implementation of an electrocardiographical signal acquisition and digital processing system orientated to the detection of paroxysmal arrhythmias

    Science.gov (United States)

    Iriart Braceli, Agustín; Exequiel Morani, Jorge

    2011-12-01

    This article describes the design, technical aspects and implementation of a device capable of acquiring electrocardiograph signals; visualize them in real time over a graphic liquid crystal display (GLCD), and the storage of these ECG registers on a SD memory card. It also details a noise suppression algorithm using the Wavelet Transform. This system was specially developed to cover some bankruptcy that presents actual Holters or ECG regarding the detection of paroxysmal arrhythmias. The contribution of this work is settled on its portability and low production cost. The filtering method used provides an ECG signal without any significant noise and appropriate to the diagnosis of cardiac pathologies.

  11. Arrhythmias and conduction abnormalities in children after repair of tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Kuzevska-Maneva Konstandina

    2005-01-01

    Full Text Available Aim. To find out types and frequency of cardiac arrhythmias and conduction abnormalities in the group of children who underwent surgery for tetralogy of Fallot (TOF. Methods. Fortysix pedicatric patients who underwent a complete repair of TOF at the age of 1 to 13 (mean 2.89 ± 2.36 were studied. Thirty-eight (82.60% had total correction and 8 (17.40% had palliative operation first, and total correction afterwards. Twenty-four-hour Holter ECG monitoring was performed in all 46 pediatric patients aged from 1 to 16 yrs (mean 6.48 ± 4.04 after surgery as follows: in 1 patient (2.17% after a year, in 20 patients (43.47% after 2 to 5 years and in 25 patients (54.34% after 5 years. Mean age of patients on Holter monitoring was 9.25 ± 4.39 (range 4−19. Twenty of them (43.47% were girls and 28 (56.53% were boys. All the patients were evaluated by standard methods (clinical signs, clinical findings, ECG before surgery, ECG before Holter monitoring and 2D Doppler echocardiography. Results. Types of heart rhythm found out by Holter monitoring were: sinus nodus dysfunction in 1 child (2.17%, significant premature atrial contraction (PAC in 8 (17.39%, supraventricular paroxysmal tachycardia in 3 (6.53%, transient nodal rhythm in 2 (4.34%, premature ventricular contraction (PVC Lown grade I-III in 9 (19.56% and Lown grade IV in 2 (4.34, atrioventricular (AV block grade I in 2, right bundle branch block (RBBB in all 46 (100% and RBBB + left anterior hemiblock (LAH in 4 (8.96%. There was no presence of atrial flutter, ventricular tachycardia or complete AV block. None of them experienced sudden death. Using cross procedure statistical methods, it was found that all the patients with PVC had right ventricular dilatation. There was no relation of other types of arrhythmia found on Holter monitoring to the other parameters from echocardiography, neither to the other standard methods. Children did not need the pace-maker, but 36.95% of the them required

  12. Cuff inflation during ambulatory blood pressure monitoring and heart rate

    Directory of Open Access Journals (Sweden)

    Mia Skov-Madsen

    2008-11-01

    Full Text Available Mia Skov-Madsen, My Svensson, Jeppe Hagstrup ChristensenDepartment of Nephrology, Aarhus University Hospital, Aalborg, DenmarkIntroduction: Twenty four-hour ambulatory blood pressure monitoring is a clinically validated procedure in evaluation of blood pressure (BP. We hypothesised that the discomfort during cuff inflation would increase the heart rate (HR measured with 24-h ambulatory BP monitoring compared to a following HR measurement with a 24-h Holter monitor.Methods: The study population (n = 56 were recruited from the outpatient’s clinic at the Department of Nephrology, Aalborg Hospital, Aarhus University Hospital at Aalborg, Denmark. All the patients had chronic kidney disease (CKD. We compared HR measured with a 24-h Holter monitor with a following HR measured by a 24-h ambulatory BP monitoring.Results: We found a highly significant correlation between the HR measured with the Holter monitor and HR measured with 24-h ambulatory blood pressure monitoring (r = 0.77, p < 0.001. Using the Bland-Altman plot, the mean difference in HR was only 0.5 beat/min during 24 hours with acceptable limits of agreement for both high and low HR levels. Dividing the patients into groups according to betablocker treatment, body mass index, age, sex, angiotensin-converting enzyme inhibitor treatment, statins treatment, diuretic treatment, or calcium channel blocker treatment revealed similar results as described above.Conclusion: The results indicate that the discomfort induced by cuff inflation during 24-h ambulatory BP monitoring does not increase HR. Thus, 24-h ambulatory BP monitoring may be a reliable measurement of the BP among people with CKD.Keywords: ambulatory blood pressure monitoring, Holter monitoring, heart rate, chronic kidney disease, hypertension

  13. Cardiac asystole following cannabis (marijuana) usage--additional mechanism for sudden death?

    Science.gov (United States)

    Menahem, Samuel

    2013-12-10

    A 21 year old university student previously operated during infancy for an unobstructed total anomalous pulmonary venous drainage with an excellent result, was noted on a routine follow up 24 h Holter monitor to have multiple pauses related to cardiac asystole, the longest lasting 5.8 s and temporally related to marijuana inhalation. A repeat Holter was normal following a two week cessation of marijuana usage and again when carried out 3 months later. The documented periods of asystole may be a precursor of sudden death seen in addicts even without evidence of ischaemic heart disease. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  14. Standard 12 Lead and 24 hour holter electrocardiographic ...

    African Journals Online (AJOL)

    Aim: To compare the cardiovascular responses to perinatal stress between two ethnic groups of newborns. Study population: 23 Nigerians and 14 Dutch perinally asphyxiated newborns together with their respective control of 12 healthy Nigerian and 16 Dutch newborns. Method: The study subjects and their controls were ...

  15. Ventricular Repolarization Evaluation From Surface ECG for Identification of the Patients With Increased Myocardial Electrical Instability

    National Research Council Canada - National Science Library

    Lass, Jaanus

    2001-01-01

    In order to reveal the possible correlation between the level of myocardial electrical instability assessed at Holter monitoring and certain ECG parameters characterizing ventricular repolarization...

  16. Intermittent versus Persistent Wolff-Parkinson-White Syndrome in Children: Electrophysiologic Properties and Clinical Outcomes.

    Science.gov (United States)

    Kiger, Michelle E; McCanta, Anthony C; Tong, Suhong; Schaffer, Michael; Runciman, Martin; Collins, Kathryn K

    2016-01-01

    Intermittent Wolff-Parkinson-White (WPW) syndrome is considered to have a lower risk of sudden death. Fewer data exist regarding electrophysiologic (EP) characteristics and the natural history of intermittent WPW in children. All patients with WPW age 1-18 years at a single institution (1996-2013) were reviewed. Patients with intermittent preexcitation were compared to those with loss of preexcitation on Holter/exercise testing and those with persistent preexcitation. High-risk accessory pathway (AP) was defined as AP effective refractory period (APERP), block cycle length, or shortest preexcited RR interval during atrial fibrillation ≤250 ms. A total of 295 patients were included: 226 (76.6%) persistent, 39 (13.2%) intermittent, and 30 (10.2%) loss of preexcitation Holter/exercise. There were no differences in symptoms between groups. Median interquartile range APERP was significantly longer in intermittent WPW (380 [320, 488] ms vs 320 [300, 350] ms persistent, 310 [290, 330] ms loss of preexcitation Holter/exercise; P = 0.0008). At baseline, there was no difference between groups in frequency of high-risk pathways. However, when isoproterenol values were included, high-risk pathways were more frequent among patients with loss of preexcitation on Holter/exercise (54% vs 16% persistent, 11% intermittent; P = 0.005). There was one death in a patient with loss of preexcitation on exercise testing, no EP study, and prior drug use. A second patient with persistent WPW and APERP 270 ms required resuscitation following a methadone overdose. Intermittent preexcitation in children does not connote a lower risk AP by EP criteria or reduced symptoms. The low number of pediatric WPW patients who develop preexcited atrial fibrillation or sudden death warrants larger studies to investigate these outcomes. ©2015 Wiley Periodicals, Inc.

  17. EVALUACIÓN DE LA DINÁMICA CARDIACA DE PACIENTES CON ARRITMIA CON BASE EN LA TEORÍA DE LA PROBABILIDAD

    Directory of Open Access Journals (Sweden)

    Javier Rodríguez

    2012-01-01

    Full Text Available Teorías físicas y matemáticas como los siste-mas dinámicos y la teoría de la probabilidad han servido como base para el desarrollo de metodo-logías diagnósticas en medicina. En este trabajo se aplicaron parámetros de evaluación asociados al número de latidos por hora, establecidos en un trabajo diagnóstico previo, a Holter de 16 pacientes con diferentes arritmias cardiacas, 3 con indicaciones de sintomatologías o patologías previas diagnos-ticados como normales y 1 normal, con edades mayores a 21 años, para estudiar la respuesta de estos parámetros a esta patología específica. Se calculó la probabilidad del número total de latidos por hora en rangos de 250 latidos/hora, evaluando la presencia de una probabilidad máxima menor a 0,217 o mayor a 0,304 y la aparición de un número menor a 3,000 o mayor a 6,250 latidos/ hora, encontrando que 12 de los holter con arritmia presentaron como mínimo una de las dos condicio-nes mencionadas, del mismo modo que los holter con antecedentes de sintomatologías o patologías previas y con diagnóstico dentro de los límites de normalidad, mientras que el holter de normalidad no presentó ninguna de estas condiciones.Los parámetros evaluados asociados a la probabilidad del número de latidos caracterizan objetivamente la dinámica cardiaca y sugieren una posible utilidad para la detección de alteraciones leves o en evolución hacia la enfermedad, siendo necesarios estudios posteriores para definir su aplicación clínica en arritmias.

  18. The Brugada syndrome. Outcome of one case

    Directory of Open Access Journals (Sweden)

    Maia Ivan G.

    2000-01-01

    Full Text Available The Brugada syndrome is a rare condition, and due to its mutating manner of presentation it may be difficult to diagnose. We report one case and discuss the diagnostic aspects and the clinical outcome of one patient with characteristic findings of this syndrome. These findings are especially defined by J-ST elevation in the right leads of serial electrocardiographic records, wide oscillations of J points and ST segments during 24-hour Holter monitoring, and nocturnal sudden death. We stress the importance of the Holter monitor findings for diagnostic complementation. Through this method it is possible to establish a correlation between vigil activities and sleep and the variability of the degree of impairment in ventricular repolarization.

  19. Perfil clínico de pacientes chagásicos e não-chagásicos portadores de marca-passo cardíaco artificial Clinical profile of Chagas and non-Chagas' disease patients with cardiac pacemaker

    Directory of Open Access Journals (Sweden)

    Leonor Garcia Rincon

    2006-06-01

    Full Text Available O objetivo do estudo foi comparar pacientes chagásicos e não-chagásicos com marca-passo cardíaco artificial uni ou bicameral quanto à fração de ejeção do ventrículo esquerdo, o limiar de estimulação ventricular e a incidência de arritmias cardíacas. Entre janeiro/2001 e novembro/2002 foram avaliados 45 pacientes chagásicos e 35 não-chagásicos portadores de marca-passo quanto à história clínica, radiografia do tórax, ecocardiograma, Holter 24h e análise telemétrica do marca-passo. Embora os chagásicos fossem mais jovens, os dois grupos foram semelhantes quanto a variáveis radiológicas e o limiar de estimulação ventricular direito. Os chagásicos apresentaram menor fração de ejeção do ventrículo esquerdo ao ecocardiograma e maior incidência de arritmia ventricular ao Holter 24h. Observou-se correlação positiva entre a baixa fração de ejeção do ventrículo esquerdo e a intensidade da arritmia ventricular ao Holter 24h. Em pacientes com marca-passo, a doença de Chagas está associada a marcadores cardíacos de prognóstico adverso.The aim of this study was to compare Chagas and non-Chagas' disease patients using single or dual-chamber pacemaker in relation to the ejection fraction of the left ventricle, the ventricular stimulation threshold and the occurrence of ventricular arrhythmia. From January, 2001 to November, 2002, 45 Chagas' disease patients and 35 non-Chagas' disease patients, all pacemaker users, were evaluated considering clinical history, echocardiographic study, Holter monitoring and analysis of the pacemaker telemetry data. Chagas' disease patients were significantly younger, but both groups were similar when chest X-Ray variables and right ventricular stimulation threshold were analyzed. Chagas' disease patients had a lower left ventricular ejection fraction and more frequent ventricular arrhythmia during Holter monitoring. A positive correlation between the low ejection fraction of the left

  20. [Evaluation of the radiofrequency ablation effectiveness in patients with the Wolff-Parkinson-White syndrome].

    Science.gov (United States)

    Ushakov, I B; Ardashev, A V; Ardashev, V N; Voronkov, Iu I; Sharoĭko, M V; Akimova, O S

    2012-01-01

    A one-year prospective study involved 22 patients with the Wolff-Parkinson-White syndrome (WPW) and 20 healthy people. Means age of patients was 34.3 +/- 16.3 years. All 22 patients were successfully treated with radiofrequency ablation (RFA) of additional pathways. RFA effectiveness was evaluated with the help of clinical questionnaire, data of ECG, EchoCG, heart rate variability (HRV), frequency response and nonlinear dynamics. Cardiac rhythm disturbances were verified using Holter monitoring applied to all patients. Positive clinical effect was achieved in all the WPW patients, as RFA arrested cardiac arrhythmias completely. Holter monitoring did not register cardiac disturbances which points to high RFA effectiveness in WPW patients. HRV, frequency response and nonlinear dynamics reassumed their normal patterns.

  1. Adapting detection sensitivity based on evidence of irregular sinus arrhythmia to improve atrial fibrillation detection in insertable cardiac monitors.

    Science.gov (United States)

    Pürerfellner, Helmut; Sanders, Prashanthan; Sarkar, Shantanu; Reisfeld, Erin; Reiland, Jerry; Koehler, Jodi; Pokushalov, Evgeny; Urban, Luboš; Dekker, Lukas R C

    2017-10-03

    Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology

  2. The Effect of Valsartan on Heart Rate Variability and Heart Rate Recovery in Patients with Mild to Moderate Mitral Stenosis

    Directory of Open Access Journals (Sweden)

    Ali Metin Esen

    2010-04-01

    Full Text Available Summary: Atrial fibrillation (AF is known to be one of the most important complications of mitral stenosis (MS. It has been reported that autonomic nervous system (ANS had an effect on AF development, heart rate variability (HRV and heart rate recovery (HRR were under the control of ANS, and their disorders were present in MS. We studied the effect of Valsartan on HRV and HRT, and thus its effect on ANS. Methods: Eleven patients (39±8 years, 10 females with mild to moderate MS were included in the study. Sixteen volunteers (38±8 years, 14 females matched for age and sex were selected for control group. All subjects underwent transthoracic echocardiography (TTE, symptom-limited treadmill test and 24 hour Holter monitorization.The patients were administered 160 mg of Valsartan daily for 14 weeks. TTE, treadmill test and Holter monitorization were repeated at the end of treatment period. In Holter monitorization, the time and frequency domain analysis of HRV and in exercise test, HRR at first and third minutes (HRR1 and HRR3 were examined. Results: Before Valsartan treatment, no significant difference was found in HRR and HRV parameters between the two groups. Systolic and diastolic blood pressure, and also HRR1values were significantly decreased after treatment of Valsartan (117±6 vs. 107±4 mmHg p<0.002, 76±6 vs. 69±9 mmHg p<0.044, 44±14 vs. 33±12 p< 0.014, respectively, while the exercise time was significantly increased (786±114 vs. 846±95 sn p< 0.044. In Holter analysis neither time nor frequency domain of HRV parameters showed a meaningful change. Conclusion: In moderate MS, treatment with Valsartan improved the effort capacity, while autonomic function parameters have been defined on the base of HRV and HRR were not significantly different.

  3. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken [Shakaihoken Chukyo Hospital, Nagoya (Japan)] [and others

    2000-05-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6{+-}14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3{+-}9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280{+-}0.0068 vs ASO group 0.0219{+-}0.0083), and gradually increased with time (1-3 years: 0.0470{+-}0.0157 vs 0.0314{+-}0.0124). (author)

  4. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    International Nuclear Information System (INIS)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken

    2000-01-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6±14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3±9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280±0.0068 vs ASO group 0.0219±0.0083), and gradually increased with time (1-3 years: 0.0470±0.0157 vs 0.0314±0.0124). (author)

  5. Cardiotoxicity in Asymptomatic Patients Receiving Adjuvant 5-fluorouracil

    DEFF Research Database (Denmark)

    Nielsen, Karin; Polk, Anne; Nielsen, Dorte Lisbet

    2014-01-01

    Evolving evidence of cardiotoxicity in cancer patients treated with 5-fluorouracil (5-FU) has been reported. We report two different clinical manifestations of asymptomatic 5-FU-associated cardiotoxicity in patients operated for colorectal cancer and treated with adjuvant chemotherapy of 5-FU...... (bolus-injection and continuous infusion for 46 hours), folinic acid and oxaliplatin (FOLFOX). For a research study evaluating cardiac events during 5-FU treatment, Holter monitoring, electrocardiogram (ECG) and echocardiography were done and cardiac markers monitored before and during the first...... and hyperlipidemia as well as an incidental finding of negative T-waves in electrocardiogram years before 5-FU treatment. No subjective cardiac symptoms were described during infusion, but approximately 12 hours after infusion she suffered from cardiac arrest but was revived. Subsequent analysis of the Holter...

  6. 24-HOUR ELECTROCARDIOGRAPHY IN CLINICAL HEALTHY CAVALIER KING CHARLES SPANIELS, WIRE-HAIRED DACHSHUNDS AND CAIRN TERRIERS

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Vesterholm, Stina; Ludvigsen, Trine Pagh

    2010-01-01

    analysis were analyzed for influence by breed, age, gender, relevant heart rate (HR) parameters and bodyweight. CKCS had a significantly higher HRex (mean 121 ± SD 12 bpm) compared to wD (94±18 bpm) (P>0.0001) and CT (102±16bpm) (P=0.0009). The minimum HR (HRmin) measured during Holter recording...... was significantly higher in CKCS (51±10 bpm) compared to wD (42±7 bpm) (P=0.001) and CT (45±7 bpm) (P=0.05). In addition, CKCS had a higher mean HR (HRmean) during Holter recording (83±13 bpm) compared to wD (68±8 bpm) (P>0.0001) and CT (75±10 bpm) (P=0.04). Both HRmean (P>0.0001) and HRmin (P=0.001) were...

  7. Impaired chronotropic response to physical activities in heart failure patients.

    Science.gov (United States)

    Shen, Hong; Zhao, Jianrong; Zhou, Xiaohong; Li, Jingbo; Wan, Qing; Huang, Jing; Li, Hui; Wu, Liqun; Yang, Shungang; Wang, Ping

    2017-05-25

    While exercise-based cardiac rehabilitation has a beneficial effect on heart failure hospitalization and mortality, it is limited by the presence of chronotropic incompetence (CI) in some patients. This study explored the feasibility of using wearable devices to assess impaired chronotropic response in heart failure patients. Forty patients with heart failure (left ventricular ejection fraction, LVEF: 44.6 ± 5.8; age: 54.4 ± 11.7) received ECG Holter and accelerometer to monitor heart rate (HR) and physical activities during symptom-limited treadmill exercise testing, 6-min hall walk (6MHW), and 24-h daily living. CI was defined as maximal HR during peak exercise testing failing to reach 70% of age-predicted maximal HR (APMHR, 220 - age). The correlation between HR and physical activities in Holter-accelerometer recording was analyzed. Of 40 enrolled patients, 26 were able to perform treadmill exercise testing. Based on exercise test reports, 13 (50%) of 26 patients did not achieve at least 70% of APMHR (CI patients). CI patients achieved a lower % APMHR (62.0 ± 6.3%) than non-CI patients who achieved 72.0 ± 1.2% of APMHR (P failure patients who took treadmill exercise testing. The wearable Holter-accelerometer recording could help to identify impaired chronotropic response to physical activities in heart failure patients. ClinicalTrials.gov ID NCT02358603 . Registered 16 May 2014.

  8. Early and late arrhythmogenic effects of doxorubicin.

    Science.gov (United States)

    Kilickap, Saadettin; Barista, Ibrahim; Akgul, Ebru; Aytemir, Kudret; Aksoy, Sercan; Tekuzman, Gulten

    2007-03-01

    To determine the incidence of early and late arrhythmogenic effects of doxorubicin-containing chemotherapy regimens. A prospective study including 29 patients who were treated with doxorubicin-containing regimens. Cardiac evaluation was based on 24-hour electrocardiographic monitorization (Holter), which was performed during the first cycle of doxorubicin-containing regimens, as well as after the last cycle of chemotherapy. The mean age of the patients was 45.8 +/- 15.1 (range 18-69). Holter records obtained during the first cycle of treatment revealed varying arrhythmias in 19 patients (65.5%) and in 18 (62.1%) patients after completion of therapy. One patient presented with syncope and both Mobitz Type 2 atrioventricular block and complete atrioventricular block were demonstrated. The patient subsequently underwent permanent pacemaker implantation. Doxorubicin may result in arrhythmias both in early and late periods of treatment. These arrhythmias are rarely life threatening.

  9. Multimodality assessment of cardiac involvement in Churg-Strauss syndrome patients in clinical remission

    International Nuclear Information System (INIS)

    Szczeklik, W.; Miszalski-Jamka, T.; Mastalerz, L.; Sokolowska, B.; Dropinski, J.; Musial, J.; Banys, R.; Hor, K.N.; Mazur, W.

    2011-01-01

    Cardiac involvement in Churg-Strauss syndrome (CSS) is not uncommon, but its frequency varies widely and may depend on the activity of the disease. Therefore, the cardiac involvement in CSS patients in clinical remission was assessed in the present study. In 20 CSS patients in remission and 20 sex- and age-matched healthy controls, an electrocardiogram (ECG) stress test, echocardiography, and 24-h ECG Holter monitoring were performed, together with cardiac magnetic resonance imaging (cMRI). Cardiac involvement was present in 90% (18/20) of CSS patients. Left ventricular ejection fraction (LVEF) was on average lower in the CSS group than in controls (P<0.05), with 7 patients showing systolic heart failure (LVEF <50%). cMRI changes included late gadolinium enhancement lesions in the LV in 89% of patients (17/19), present in all layers of the myocardium. Signs of ongoing inflammation (early gadolinium enhancement) and edema (T2-weighted imaging) were present in 6/19 patients. Holter monitoring revealed both supraventricular and ventricular arrhythmias more frequently in CSS patients when compared with controls (P<0.05). Absolute eosinophil count before the initiation of treatment was higher in rhythm disturbances (P<0.05), and inversely correlated with LV systolic function (rho -0.65). Heart involvement in CSS patients who are in clinical remission is very common. It is characterized not only by fibrosis, but also by an active inflammatory process. The latter finding might influence therapeutic decisions in CSS patients in full clinical remission. (author)

  10. Multimodality assessment of cardiac involvement in Churg-Strauss syndrome patients in clinical remission

    Energy Technology Data Exchange (ETDEWEB)

    Szczeklik, W; Miszalski-Jamka, T; Mastalerz, L; Sokolowska, B; Dropinski, J; Musial, J [Medical Coll., Jagiellonian Univ., Krakow (Poland); Banys, R [John Paul II Hospital, Krakow (Poland); Hor, K N [Cincinnati Children' s Medical Center, OH (United States); Mazur, W [Heart and Vascular Center at The Christ Hospitals, OH (United States)

    2011-02-15

    Cardiac involvement in Churg-Strauss syndrome (CSS) is not uncommon, but its frequency varies widely and may depend on the activity of the disease. Therefore, the cardiac involvement in CSS patients in clinical remission was assessed in the present study. In 20 CSS patients in remission and 20 sex- and age-matched healthy controls, an electrocardiogram (ECG) stress test, echocardiography, and 24-h ECG Holter monitoring were performed, together with cardiac magnetic resonance imaging (cMRI). Cardiac involvement was present in 90% (18/20) of CSS patients. Left ventricular ejection fraction (LVEF) was on average lower in the CSS group than in controls (P<0.05), with 7 patients showing systolic heart failure (LVEF <50%). cMRI changes included late gadolinium enhancement lesions in the LV in 89% of patients (17/19), present in all layers of the myocardium. Signs of ongoing inflammation (early gadolinium enhancement) and edema (T2-weighted imaging) were present in 6/19 patients. Holter monitoring revealed both supraventricular and ventricular arrhythmias more frequently in CSS patients when compared with controls (P<0.05). Absolute eosinophil count before the initiation of treatment was higher in rhythm disturbances (P<0.05), and inversely correlated with LV systolic function (rho -0.65). Heart involvement in CSS patients who are in clinical remission is very common. It is characterized not only by fibrosis, but also by an active inflammatory process. The latter finding might influence therapeutic decisions in CSS patients in full clinical remission. (author)

  11. Silent ischemia in patients after the acute myocardial infarction

    International Nuclear Information System (INIS)

    Samarzija, M.

    1991-01-01

    The purpose of this study was to determine the frequency and importance of silent ischemia in patients (pts) after acute myocardial infarction (AMI) as well as to establish diagnostic and prognostic values of exercise stress test (EST), Holter (H) monitoring and thallium-201 (Tl) scintigraphy. All the tests were performed 2-4 months following the AMI. The criterion for diagnostic myocardial ischemia on EST and H is 1 mm or more of horizontal or down-sloping ST depression. Additional criteria for Holter imply that the ischemic episode should last one minute and be separated from other episodes by at least one minute. Planar thallium images were performed 5-10 minutes after the stress test; the delayed images were obtained after 3-6 hours. Visual and quantitative methods were employed in the analysis of Tl-scintigraphy. Scintigraphy was considered positive if exercise-induced perfusion defects showed redistribution. The study included 74 asymptomatic patients after the AMI. The patients were divided into two groups by results of quantitative Tl-scintigraphy: Group I - 44 pts with silent ischemia, Group II - 30 pts without ischemia. In Group I, out of 44 pts, 9 had a positive exercise stress test, 4 showed a painless ST depression on Holter and 7 had both tests positive, whereas 24 pts had only scintigraphy positive. In Group II one patient had positive EST and H. Sensitivity and specificity were determined by results of coronary arteriography performed on 33 pts: EST (Se=40%, Sp=80%), H (Se=21%, Sp=100%) and scintigraphy (Se=93%, Sp=80%). During the follow-up period lasting at least 12 months, in Group I 3 pts died, 1 developed a new myocardial infarction and 15 pts had painful ischemic occurrences. In Group II only 3 pts developed symptoms of angina pectoris. Tl-scintigraphy was the only non-invasive test showing significant correlation with the follow-up outcomes. The diagnostic and prognostic superiority of Tl-scintigraphy justifies its value as an initial

  12. Silent ischemia in patients after uncomplicated myocardial infarction

    International Nuclear Information System (INIS)

    Samarzija, M.; Tezak, S.

    1994-01-01

    The purpose of this study was to determine the frequency and importance of silent ischemia in patients (pts) after the acute myocardial infarction (A MI) as well as to establish diagnostic and prognostic value of exercise stress test (EST), Holter (H) monitoring and thallium-201 (Tl) scintigraphy. All the three tests were performed 2-4 months following the AMI. The criterion for diagnosing myocardial ischemia on EST and H is 1 mm or more of horizontal or down-sloping ST depression. Additional criteria for Holter imply the ischemic episode should last one minute and be separated from other episodes by at least one minute. Planar thallium images were performed 5-10 minute after the stress test; the delayed images were obtained after 3-6 hours. Visual and quantitative methods were employed in the analysis of TI-scintigraphy. Scintigraphy was considered positive if exercise- induced perfusion defects showed redistribution. The study included 74 asymptomatic patients after the AMI. The patients were divided into two groups by results of quantitative Tl-scintigraphy: Group I - 44 pts with silent ischemia, Group II - 30 pts without ischemia. In Group I, out of 44 pts, 9 had a positive exercise stress, 4 showed a painless ST depression on Holter and 7 had both tests positive, whereas 24 pts had only scintigraphy positive. In Group II one patient had positive EST and H. Sensitivity and specificity were determined by results of coronary arteriography performed on 33 pts: EST (Se=40%, Sp=80%), H (Se=219, Sp=100%) and scintigraphy (Se=93%, Sp =80%). During the follow-up period lasting at least 12 months, in Group I 3 pts died, 1 developed a new myocardial infarction and 15 pts had painful ischemic occurrences. In Group II only 3 pts developed symptoms of angina pectoris. Tl-scintigraphy was the only non-invasive test showing significant correlation with the follow-up outcomes. The diagnostic and prognostic superiority of Tl-scintigraphy justifies its value as the initial

  13. α-Glucosidase inhibitor miglitol attenuates glucose fluctuation, heart rate variability and sympathetic activity in patients with type 2 diabetes and acute coronary syndrome: a multicenter randomized controlled (MACS) study.

    Science.gov (United States)

    Shimabukuro, Michio; Tanaka, Atsushi; Sata, Masataka; Dai, Kazuoki; Shibata, Yoshisato; Inoue, Yohei; Ikenaga, Hiroki; Kishimoto, Shinji; Ogasawara, Kozue; Takashima, Akira; Niki, Toshiyuki; Arasaki, Osamu; Oshiro, Koichi; Mori, Yutaka; Ishihara, Masaharu; Node, Koichi

    2017-07-06

    Little is known about clinical associations between glucose fluctuations including hypoglycemia, heart rate variability (HRV), and the activity of the sympathetic nervous system (SNS) in patients with acute phase of acute coronary syndrome (ACS). This pilot study aimed to evaluate the short-term effects of glucose fluctuations on HRV and SNS activity in type 2 diabetes mellitus (T2DM) patients with recent ACS. We also examined the effect of suppressing glucose fluctuations with miglitol on these variables. This prospective, randomized, open-label, blinded-endpoint, multicenter, parallel-group comparative study included 39 T2DM patients with recent ACS, who were randomly assigned to either a miglitol group (n = 19) or a control group (n = 20). After initial 24-h Holter electrocardiogram (ECG) (Day 1), miglitol was commenced and another 24-h Holter ECG (Day 2) was recorded. In addition, continuous glucose monitoring (CGM) was performed throughout the Holter ECG. Although frequent episodes of subclinical hypoglycemia (≤4.44 mmo/L) during CGM were observed on Day 1 in the both groups (35% of patients in the control group and 31% in the miglitol group), glucose fluctuations were decreased and the minimum glucose level was increased with substantial reduction in the episodes of subclinical hypoglycemia to 7.7% in the miglitol group on Day 2. Holter ECG showed that the mean and maximum heart rate and mean LF/HF were increased on Day 2 in the control group, and these increases were attenuated by miglitol. When divided 24-h time periods into day-time (0700-1800 h), night-time (1800-0000 h), and bed-time (0000-0700 h), we found increased SNS activity during day-time, increased maximum heart rate during night-time, and glucose fluctuations during bed-time, which were attenuated by miglitol treatment. In T2DM patients with recent ACS, glucose fluctuations with subclinical hypoglycemia were associated with alterations of HRV and SNS activity, which were mitigated by

  14. Monitorização eletrocardiográfica ambulatorial por 24-horas em cães com cardiomiopatia dilatada idiopática Twenty-four-hour ambulatory electrocardiographic monitoring in dogs with idiopathic dilated cardiomyopathy

    Directory of Open Access Journals (Sweden)

    F.L. Yamaki

    2007-12-01

    Full Text Available Caracterizou-se monitorização eletrocardiográfica ambulatorial por 24 horas (ou monitorização Holter em cães com cardiomiopatia dilatada idiopática, visando principalmente à detecção de arritmias ventriculares não detectadas pela eletrocardiografia convencional (de repouso. Para tanto, avaliaram-se 40 pacientes com diagnóstico de cardiomiopatia dilatada idiopática, por meio de exame físico e mensuração indireta da pressão arterial, além de exames eletrocardiográfico, ecocardiográfico, radiográfico de tórax e da monitorização Holter. Extra-sístoles ventriculares foram detectadas, por monitorização Holter, em 97,5% dos animais e taquicardia ventricular, em 45%. Não houve correlação entre o número de extra-sístoles ventriculares e a fração de encurtamento. Considerando as manifestações clínicas, apenas houve associação entre presença de taquicardia ventricular e histórico de síncopes. Conclui-se que a incidência de arritmias ventriculares em cães com cardiomiopatia dilatada idiopática é bastante alta, sendo a taquicardia ventricular relativamente freqüente, ocorrendo mais sob a forma não sustentada.This study aimed to characterize 24-hour ambulatory electrocardiographic monitoring (Holter monitoring in dogs with idiopathic dilated cardiomyopathy. Physical examination and indirect (Doppler blood pressure measurement, and also electrocardiography, thoracic radiography, echocardiography, and 24-hour ambulatory electrocardiographic exams were performed in 40 dogs with idiopathic dilated cardiomyopathy. Ventricular extrasystoles were detected in 97.5% of the animals, and ventricular tachycardia in 45%. No correlation between the number of ventricular extrasystoles and the shortening fraction was observed. Concerning the clinical symptoms, there was only association between the presence of ventricular tachycardia and past report of syncope. It was concluded that the incidence of ventricular arrhythmias is

  15. Ventricular arrhythmia burst is an independent indicator of larger infarct size even in optimal reperfusion in STEMI

    NARCIS (Netherlands)

    van der Weg, Kirian; Majidi, Mohamed; Haeck, Joost D. E.; Tijssen, Jan G. P.; Green, Cynthia L.; Koch, Karel T.; Kuijt, Wichert J.; Krucoff, Mitchell W.; Gorgels, Anton P. M.; de Winter, Robbert J.

    2016-01-01

    We hypothesized that ventricular arrhythmia (VA) bursts during reperfusion phase are a marker of larger infarct size despite optimal epicardial and microvascular perfusion. 126 STEMI patients were studied with 24h continuous, 12-lead Holter monitoring. Myocardial blush grade (MBG) was determined and

  16. Use of left ventricular ejection fraction or wall-motion score index in predicting arrhythmic death in patients following an acute myocardial infarction. The TRACE Study Group

    DEFF Research Database (Denmark)

    Køber, L; Torp-Pedersen, C; Elming, H

    1997-01-01

    on the correlation between arrhythmic death and "sudden unexpected death" defined as death within 1 hour of onset of new symptoms. Assessment of late potentials, heart rate variability (HRV), T wave alternans, arrhythmias seen on Holter monitoring or during exercise testing, electrophysiological testing...

  17. Heart Rate Variability Density Analysis (Dyx) and Prediction of Long-Term Mortality after Acute Myocardial Infarction

    DEFF Research Database (Denmark)

    Jørgensen, Rikke Mørch; Abildstrøm, Steen Z; Levitan, Jacob

    2016-01-01

    AIMS: The density HRV parameter Dyx is a new heart rate variability (HRV) measure based on multipole analysis of the Poincaré plot obtained from RR interval time series, deriving information from both the time and frequency domain. Preliminary results have suggested that the parameter may provide...... new predictive information on mortality in survivors of acute myocardial infarction (MI). This study compares the prognostic significance of Dyx to that of traditional linear and nonlinear measures of HRV. METHODS AND RESULTS: In the Nordic ICD pilot study, patients with an acute MI were screened...... with 2D echocardiography and 24-hour Holter recordings. The study was designed to assess the power of several HRV measures to predict mortality. Dyx was tested in a subset of 206 consecutive Danish patients with analysable Holter recordings. After a median follow-up of 8.5 years 70 patients had died...

  18. Descriptive evaluation of holter recordings at a teaching hospital in ...

    African Journals Online (AJOL)

    Wide QRS complex tachycardia was detected in 20.4%, ST segment depression in 47.8% and atrial fibrillation in 28.7%. Asystole was seen in 18% of subjects with a mean duration of 2.17secs, arrest was recorded in 26.7% of those with asystole. The longest duration was 7.58secs. Premature atrial ectopics were seen in ...

  19. Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Mittal, Suneet; Ruwald, Anne-Christine

    2014-01-01

    -defibrillator device with data available on biventricular pacing percentage and pre-implantation 24-h Holter recordings were included. Using logistic regression, we estimated the influence of ectopic beats on the percentage of biventricular pacing. Reverse remodeling was measured as reductions in atrial and left...

  20. 76 FR 25732 - Order of Suspension of Trading; In the Matter of Advanced Refractive Technologies, Inc., Bluebook...

    Science.gov (United States)

    2011-05-05

    ... of Advanced Refractive Technologies, Inc., Bluebook International Holding Co. (The), CBCom, Inc., Gener8xion Entertainment, Inc., Group Long Distance Inc., HiEnergy Technologies, Inc., and Holter Technologies Holding, A.G. (n/k/a International Consortium Corp.) It appears to the Securities and Exchange...

  1. Highland Medical Research Journal - Vol 15, No 2 (2015)

    African Journals Online (AJOL)

    Descriptive evaluation of holter recordings at a teaching hospital in central Nigeria · EMAIL FULL TEXT EMAIL FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Caleb M. Chundusu, Maxwel O. Akanbi, James A. Onuh, Ganiyu A. Amusa, Solomon S. Danbauchi, Basil N. Okeahialam, 59-62 ...

  2. Complete paroxysmal atrioventricular block in a 2-year-old girl

    DEFF Research Database (Denmark)

    Holst, Line Marie; Dixen, Ulrik; Jeppesen, Dorthe L

    2015-01-01

    We present a case of atypical syncope in a 2-year-old, otherwise healthy girl. The patient presented with three episodes of syncope without any precipitating factors and no family history of sudden unexpected death. Holter monitoring revealed 24 events of complete atrioventricular block lasting up...

  3. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    Science.gov (United States)

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  4. A new after-loading intrauterine packing device: ten years experience.

    Science.gov (United States)

    Sklaroff, D M; Baker, A S; Tasbas, M

    1985-12-01

    A new variation of the uterine packing device for the treatment of endometrial carcinoma is described. It combines the advantages of the Holter technique with the after-loading method described by Simon. This device has been in use for more than 10 years and has been found most satisfactory.

  5. New after-loading intrauterine packing device: ten years experience

    International Nuclear Information System (INIS)

    Sklaroff, D.M.; Baker, A.S.; Tasbas, M.

    1985-01-01

    A new variation of the uterine packing device for the treatment of endometrial carcinoma is described. It combines the advantages of the Holter technique with the after-loading method described by Simon. This device has been in use for more than 10 years and has been found most satisfactory

  6. Effects of citalopram on heart rate variability in women with generalized anxiety disorder

    Directory of Open Access Journals (Sweden)

    Fatemeh Ranjbar

    2015-07-01

    Full Text Available BACKGROUND: Heart rate variability (HRV is defined as variations in R-R interval with time. Dysautonomia is common in patients with psychiatric disorders such as depression and anxiety. Using HRV analysis, recent studies showed that in anxiety disorders, the vagal cardiac function decreases, and sympathetic function increases. This study aimed at investigating citalopram effects on HRV. METHODS: This before and after study was conducted in 25 generalized anxiety disorder (GAD patients. GAD was diagnosed based on clinical interview according to diagnostic and statistical manual of mental disorders IV-Text revised (DSM-IV-TR criteria using Structured Clinical Interview for DSM Disorders-I questionnaire. A cardiologist studied 24 h ambulatory monitoring of the electrocardiogram (Holter on all patients before the treatment. A volume of 20 mg of citalopram was administered to the subjects on a daily basis. Then, they were studied by Holter monitoring again after 1-month of administration of citalopram. RESULTS: The average age of participants was 35.32 ± 8.7. The average Holter monitoring time was 23.29 ± 1.14 h before treatment and 23.81 ± 0.68 after it. The 3 h low frequency/high frequency ratio was significantly different between 3 h segments of time before treatment (P < 0.001. This difference was even higher after treatment (P = 0.001. Data showed an increase in parasympathetic tone during sleep both before and after treatment. CONCLUSION: These patients showed some impairments of HRV indices that did not improve by citalopram in future, the clinical importance of such disturbances should be evaluated in details with prolonged follow-up and greater sample size.   

  7. Alterações contráteis segmentares e sua associação com arritmias ventriculares complexas, em pacientes chagásicos com eletrocardiograma normal ou borderline Regional left ventricular dysfunction and its association with complex ventricular arrhythmia, in chagasic patients with normal or borderline electrocardiogram

    Directory of Open Access Journals (Sweden)

    Flavia Vernin de Oliveira Terzi

    2010-10-01

    Full Text Available INTRODUÇÃO: Morte súbita representa a principal causa de óbito em chagásicos. Eventos fatais em pacientes saudáveis, com anormalidades contráteis, foram documentados. O objetivo deste trabalho é determinar a associação entre alteração contrátil e arritmias ventriculares complexas em pacientes chagásicos, classe funcional I, eletrocardiograma normal ou borderline e função ventricular preservada. MÉTODOS: Quarenta e nove pacientes com doença de Chagas e eletrocardiograma normal ou borderline realizaram ecocardiograma, teste ergométrico e Holter. Avaliou-se a contratilidade global e segmentar dos ventrículos e a presença de arritmias ventriculares complexas induzidas no esforço e espontâneas, respectivamente. A análise estatística foi feita pelo modelo Log-Linear geral. RESULTADOS: Idade média de 56 anos; 55% mulheres. Alterações contráteis segmentares em 24,5% dos pacientes; 12% dos Holter e 18% dos testes ergométricos positivos. Houve associação entre arritmia e alteração segmentar condicionada à presença da disfunção sistólica leve do ventrículo esquerdo. CONCLUSÕES: Alterações contráteis, na presença de disfunção global leve, indicam pacientes sob maior risco de arritmias complexas.INTRODUCTION: Sudden death is the major cause of death among chagasic patients. A significant number of fatal events in patients without apparent heart disease and borderline electrocardiogram, but with contractile ventricular dysfunction, have been documented. This work aimed to determine the association between regional dysfunction and the presence of ventricular arrhythmia in chagasic patients without apparent heart disease. METHODS: Forty-nine patients with normal or borderline electrocardiogram were submitted to echocardiogram, exercise stress test and Holter. The presence of cardiac contractile alterations and complex ventricular arrhythmia was analyzed. Statistic analysis used the general Log-Linear model. RESULTS

  8. Haptoglobin genotype and risk markers of cardiovascular disease in patients with chronic kidney disease

    DEFF Research Database (Denmark)

    Strandhave, Charlotte; Svensson, My; Krarup, Henrik

    2013-01-01

    -5 were included. Hp genotype was determined by high-performance liquid chromatography. HRV was analysed from the 24 h Holter recordings. Hs-CRP was measured using an immunoturbidimetric assay. The results show that the HRV indices SDNN and SDANN were significantly lower in the Hp 2-2 patients (P = 0...

  9. Heart Rate Variability and Drawing Impairment in Hypoxemic COPD

    Science.gov (United States)

    Incalzi, Raffaele Antonelli; Corsonello, Andrea; Trojano, Luigi; Pedone, Claudio; Acanfora, Domenico; Spada, Aldo; D'Addio, Gianni; Maestri, Roberto; Rengo, Franco; Rengo, Giuseppe

    2009-01-01

    We studied 54 patients with hypoxemic chronic obstructive pulmonary disease (COPD). The Mini Mental State Examination and the Mental Deterioration Battery were used for neuropsychological assessment. Heart rate variability (HRV) was assessed based on 24-h Holter ECG recording. Mann-Whitney test was used to compare HRV parameters of patients…

  10. Forecasting of primary energy consumption data in the United States: A comparison between ARIMA and Holter-Winters models

    Science.gov (United States)

    Rahman, A.; Ahmar, A. S.

    2017-09-01

    This research has a purpose to compare ARIMA Model and Holt-Winters Model based on MAE, RSS, MSE, and RMS criteria in predicting Primary Energy Consumption Total data in the US. The data from this research ranges from January 1973 to December 2016. This data will be processed by using R Software. Based on the results of data analysis that has been done, it is found that the model of Holt-Winters Additive type (MSE: 258350.1) is the most appropriate model in predicting Primary Energy Consumption Total data in the US. This model is more appropriate when compared with Holt-Winters Multiplicative type (MSE: 262260,4) and ARIMA Seasonal model (MSE: 723502,2).

  11. Measure of the QT-RR Dynamic Coupling in Patients with the Long QT Syndrome

    Czech Academy of Sciences Publication Activity Database

    Halámek, Josef; Couderc, J. P.; Jurák, Pavel; Vondra, Vlastimil; Zareba, W.; Viščor, Ivo; Leinveber, P.

    2012-01-01

    Roč. 17, č. 4 (2012), s. 323-330 ISSN 1082-720X R&D Projects: GA MŠk ME09050 Institutional support: RVO:68081731 Keywords : Long QT syndrome * Dynamic QT-RR coupling * Holter recording * QT adaptation * QT parameters Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.084, year: 2012

  12. A microcontroller-based portable electrocardiograph recorder.

    Science.gov (United States)

    Segura-Juárez, José J; Cuesta-Frau, David; Samblas-Pena, Luis; Aboy, Mateo

    2004-09-01

    We describe a low cost portable Holter design that can be implemented with off-the-shelf components. The recorder is battery powered and includes a graphical display and keyboard. The recorder is capable of acquiring up to 48 hours of continuous electrocardiogram data at a sample rate of up to 250 Hz.

  13. CONTINUOUS HOLTER MONITORING OF PATIENTS WITH CARDIOVASCULAR DISEASES IN ORAL SURGERY

    OpenAIRE

    Hristo Daskalov; Lyudmila Vladimirova-Kitova; F. Nikolov; E. Sarachev

    2011-01-01

    Introduction. Pain control and anxiety management are important aspects of modern dental treatment. Although many local anesthetics and anesthesia techniques have so far been studied, there is still no clarity as to what anesthetic should be used in cardiovascularly compromised patients. This anesthetic and its dosage should be very carefully chosen to achieve optimal effective pain control; the possible side effects occurring mainly in morbidly compromised patients should also be well studie...

  14. CONTINUOUS HOLTER MONITORING OF PATIENTS WITH CARDIOVASCULAR DISEASES IN ORAL SURGERY

    Directory of Open Access Journals (Sweden)

    Hristo Daskalov

    2011-09-01

    Full Text Available Introduction. Pain control and anxiety management are important aspects of modern dental treatment. Although many local anesthetics and anesthesia techniques have so far been studied, there is still no clarity as to what anesthetic should be used in cardiovascularly compromised patients. This anesthetic and its dosage should be very carefully chosen to achieve optimal effective pain control; the possible side effects occurring mainly in morbidly compromised patients should also be well studied.Methods. The aim of this study was to study the effect of vasoconstrictors on local anesthetics in 18 patients with heart diseases. The study contingent was recruited from the patients visiting often their general dental practitioners and diagnosed with the following heart diseases: Heart failure (after 6 months; ischemic heart disease, including mild angina pectoris. Articaine was used as local anesthetic. Results. The ST segment on the ECG was used to detect myocardial ischemia and to study the effect of the administered local anesthesia.Conclusion. The study results suggest that pain control in a cardiovascularly compromised patient subjected to oral surgery should be carried out only after thorough analysis is conducted of the specific condition and current status of the patient. Additional hematological tests shoud be done to enable the dentist to build a viable treatment plan.

  15. Atrial fibrillation is not uncommon among patients with ischemic stroke and transient ischemic stroke in China.

    Science.gov (United States)

    Yang, Xiaomeng; Li, Shuya; Zhao, Xingquan; Liu, Liping; Jiang, Yong; Li, Zixiao; Wang, Yilong; Wang, Yongjun

    2017-12-04

    Atrial fibrillation (AF) is reported to be a less frequent cause of ischemic stroke in China than in Europe and North America, but it is not clear whether this is due to underestimation. Our aim was to define the true frequency of AF-associated stroke, to determine the yield of 6-day Holter ECG to detect AF in Chinese stroke patients, and to elucidate predictors of newly detected AF. Patients with acute ischemic stroke or transient ischemic attack (TIA) were enrolled in a prospective, multicenter cohort study of 6-day Holter monitoring within 7 days after stroke onset at 20 sites in China between 2013 and 2015. Independent predictors of newly-detected AF were determined by multivariate analysis. Among 1511 patients with ischemic stroke and TIA (mean age 63 years, 33.1% women), 305 (20.2%) had either previously known (196, 13.0%) or AF newly-detected by electrocardiography (53, 3.5%) or by 6-day Holter monitoring (56/1262, 4.4%). A history of heart failure (OR = 4.70, 95%CI, 1.64-13.5), advanced age (OR = 1.06, 95%CI, 1.04-1.09), NIHSS at admission (OR = 1.06, 95%CI, 1.02-1.10), blood high density lipoprotein (HDL) (OR = 1.52, 95%CI, 1.09-2.13), together with blood triglycerides (OR = 0.64, 95%CI, 0.45-0.91) were independently associated with newly-detected AF. Contrary to previous reports, AF-associated stroke is frequent (20%) in China if systemically sought. Prolonged noninvasive cardiac rhythm monitoring importantly increases AF detection in patients with recent ischemic stroke and TIA in China. Advanced age, history of heart failure, and higher admission NIHSS and higher level of HDL were independent indicators of newly-detected AF. NCT02156765 (June 5, 2014).

  16. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    International Nuclear Information System (INIS)

    Sultana, R.; Sultana, N.; Rashid, A.; Rasheed, S.Z.; Ahmed, M.; Ishaq, M.; Samad, A.

    2010-01-01

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  17. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sultana, R; Sultana, N; Rashid, A; Rasheed, S Z; Ahmed, M; Ishaq, M; Samad, A [Karachi Institute of Heart Diseases, Karachi (Pakistan)

    2010-10-15

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  18. Current investigation and management of patients with syncope

    DEFF Research Database (Denmark)

    Dagres, Nikolaos; Bongiorni, Maria Grazia; Dobreanu, Dan

    2013-01-01

    and indications for tilt table testing in neurally mediated syncope. The majority of centres reported using ECG, echocardiography, and Holter monitoring as their main diagnostic tools in patients with syncope, whereas a smaller proportion of centres applied specific assessment algorithms. Physical manoeuvres were...... almost uniformely reported as the standard treatment for neurally mediated syncope....

  19. Heart rate variability in healthy population

    International Nuclear Information System (INIS)

    Alamgir, M.; Hussain, M.M.

    2010-01-01

    Background: Heart rate variability has been considered as an indicator of autonomic status. Little work has been done on heart rate variability in normal healthy volunteers. We aimed at evolving the reference values of heart rate variability in our healthy population. Methods: Twenty-four hour holter monitoring of 37 healthy individuals was done using Holter ECG recorder 'Life card CF' from 'Reynolds Medical'. Heart rate variability in both time and frequency domains was analysed with 'Reynolds Medical Pathfinder Digital/700'. Results: The heart rate variability in normal healthy volunteers of our population was found in time domain using standard deviation of R-R intervals (SDNN), standard deviation of average NN intervals (SDANN), and Square root of the mean squared differences of successive NN intervals (RMSSD). Variation in heart rate variability indices was observed between local and foreign volunteers and RMSSD was found significantly increased (p<0.05) in local population. Conclusions: The values of heart rate variability (RMSSD) in healthy Pakistani volunteers were found increased compared to the foreign data reflecting parasympathetic dominance in our population. (author)

  20. Conventional heart rate variability analysis of ambulatory electrocardiographic recordings fails to predict imminent ventricular fibrillation

    Science.gov (United States)

    Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.

    1993-01-01

    OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.

  1. Ambulatory monitoring of myocardial ischemia in the 21st century-an opportunity for high frequency QRS analysis

    Czech Academy of Sciences Publication Activity Database

    Leinveber, Pavel; Halámek, Josef; Jurák, Pavel

    2016-01-01

    Roč. 49, č. 6 (2016), s. 902-906 ISSN 0022-0736 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : ambulatory monitoring * HF-QRS * myocardial Ischemia * silent Ischemia * Holter monitoring Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.514, year: 2016

  2. Low Incidence of Atrial Fibrillation in Patients with Transient Ischemic Attack

    DEFF Research Database (Denmark)

    Pedersen, Kenneth Bruun; Chemnitz, Alexander; Madsen, Charlotte

    2016-01-01

    on admission ECG. Another 2 (1.2%) were diagnosed with AF on Holter monitoring. In total, 6 patients (3.5%) were diagnosed with AF. Patients with AF were significantly older (mean age 79.4 [95% CI 65.1-93.6] years) than patients without AF (mean age 67.6 [95% CI 65.6-69.5] years) but otherwise showed...

  3. Análise da variabilidade da freqüência cardíaca em pacientes hipertensos, antes e depois do tratamento com inibidores da enzima conversora da angiotensina II Analysis of heart rate variability in hypertensive patients before and after treatment with angiotensin II-converting enzyme inhibitors

    Directory of Open Access Journals (Sweden)

    Antônio da Silva Menezes Júnior

    2004-08-01

    Full Text Available OBJETIVO: Comparar a variabilidade de freqüência cardíaca em indivíduos normotensos e hipertensos e observar o comportamento do sistema nervoso autônomo após terapia com inibidores da enzima conversora de angiotensina II. MÉTODO: Estudados 286 pacientes com diagnóstico de hipertensão arterial, pela 1ª vez, e divididos em 4 grupos, conforme a pressão arterial diastólica (PAD: grupo A - PAD110 mmHg. Os pacientes do grupo A (normais e do grupo C (HA moderada, somando 110 e 79 pacientes, respectivamente, submeteram-se ao Holter-ECG 24h com análise de variabilidade de freqüência cardíaca no domínio do tempo (DT e no domínio da freqüência (DF. O grupo C foi tratado com inibidores da ECA durante 3 meses, e após esse período novamente avaliado com Holter-ECG 24h e variabilidade da freqüência cardíaca, e os valores comparados com os normotensos. RESULTADOS: Os parâmetros SDNN, PNN50 (DT e o espectro LF (DF foram significativamente diferentes para os dois grupos, com valores notadamente diminuídos em hipertensos (pOBJECTIVE: To compare heart rate variability in normotensive and hypertensive individuals and to observe the behavior of the autonomic nervous system after treatment with angiotensin II-converting enzyme inhibitors. METHOD: The study comprised 286 patients diagnosed with arterial hypertension (AH for the first time and divided into 4 groups according to diastolic blood pressure (DBP levels: group A - DBP110 mmHg. Group A (110 healthy individuals and group C (79 patients with moderate AH underwent 24-hour Holter-ECG with analysis of heart rate variability in time domain (TD and frequency domain (FD. The group C patients were treated with ACE inhibitors for 3 months, and, after this period, they underwent a new 24-hour Holter-ECG study for assessing heart rate variability, the values being compared with those of normotensive individuals. RESULTS: The SDNN and PNN50 parameters (TD, and the LF spectrum (FD were

  4. Buerger's Disease and Anaesthesia: The Neglected Cardiac Angle

    Directory of Open Access Journals (Sweden)

    Shagun Bhatia Shah

    2015-08-01

    Full Text Available Distal limb amputations and respiratory complications are common in patients with Buerger’s disease. Nicotine in cigarette is arrhythmogenic as it blocks cardiac potassium channels. Preoperative Holter ECG monitoring may be useful if preoperative electrocardiogram is normal. If the patient is undergoing major surgery, preservative free lignocaine & amiodarone infusions and a cardioverter defibrillator should be available for the intraoperative cardiac rhythm disturbances.

  5. Evaluation of proportional health impairment due to occupationally related myocardial infarction

    International Nuclear Information System (INIS)

    Szozda, R.; Schneiberg, P.

    1995-01-01

    The authors propose the principles how to calculate a proportional health impairment due to myocardial infarction. The proposals are based on own experience, literature and regulations. It is suggested that the following should be taken into account for the calculation purposes: case history, resting electrocardiogram, postexercise electrocardiogram, results of Holter's examination, chest X-ray including evaluation of the heart silhouette and UCG. (author). 8 refs, 3 tabs

  6. Features of conngestive heart failure development in patients with post infarct cardiosclerosis concomitant with arrhythmias

    International Nuclear Information System (INIS)

    Zharov, E.I.; Martynov, A.I.; Vertkin, A.L.; Sergeeva, L.I.; Sedov, V.P.

    1989-01-01

    Two hundred and seventy seven patients with coronary heart disease, includng 182 with postinfarction cardiosclerosis undewent 24-hour Holter monitoring. A significant correlation was found between the number of coupled ventricular arrhythmias, ventricular tachycardia paroxysms and developmet of congestive heart failure in patients with postinfarct cardiosclerosis. With evolving metabolic deficiency as evidenced by thallium-201 myocardial scintigraphy, the incidence of congestive heart failure and ventricular arrhythmias increased among the patients

  7. Heart Rate Variability Correlates to Functional Aerobic Impairment in Hemodialysis Patients

    Directory of Open Access Journals (Sweden)

    Maria Angela Magalhães de Queiroz Carreira

    2015-06-01

    Full Text Available Background: Autonomic dysfunction (AD is highly prevalent in hemodialysis (HD patients and has been implicated in their increased risk of cardiovascular mortality. Objective: To correlate heart rate variability (HRV during exercise treadmill test (ETT with the values obtained when measuring functional aerobic impairment (FAI in HD patients and controls. Methods: Cross-sectional study involving HD patients and a control group. Clinical examination, blood sampling, transthoracic echocardiogram, 24-hour Holter, and ETT were performed. A symptom-limited ramp treadmill protocol with active recovery was employed. Heart rate variability was evaluated in time domain at exercise and recovery periods. Results: Forty-one HD patients and 41 controls concluded the study. HD patients had higher FAI and lower HRV than controls (p<0.001 for both. A correlation was found between exercise HRV (SDNN and FAI in both groups. This association was independent of age, sex, smoking, body mass index, diabetes, and clonidine or beta-blocker use, but not of hemoglobin levels. Conclusion: No association was found between FAI and HRV on 24-hour Holter or at the recovery period of ETT. Of note, exercise HRV was inversely correlated with FAI in HD patients and controls. (Arq Bras Cardiol. 2015; [online]. ahead print, PP.0-0

  8. Assesment of Rhythm Disorders in Classical and Nonclassical Mitral Valve Prolapse.

    Science.gov (United States)

    Hodzic, Enisa

    2018-02-01

    Mitral Valve Prolapse (MVP) is the most common cardiac valve pathology of to day. Aim of article was to identify the types and frequency of potentially malignant arrhythmia and atrial brillation in patients with MVP, to determine the differences in these arrhythmias between classical and non-classical MVP, to evaluate the correlation of potentially malignant arrhythmia and atrial fibrillation with MVP with possible clinical complications of arrhythmogenic sudden cardiac death and potential risk of thromboembolic vascular incident. Article has retrospective-prospective analytical character and present observational study on 239 patients (120 with MVP (66 with classical and 54 with non-classical MVP), who had a subjective feeling of palpitations and/or pain in the chest, and/or episode of syncope, and did not have ischemic heart disease or another valve pathology) and 119 healthy patients in the control group. All patients were analyzed by 24-hour ECG Holter. Signifficant difference in all analyzed arrhythmias between classical MVP and control group (p MVP (p = 0.016). The potential risk of cardiac death and vascular incidence is signi cantly higher in classical MVP than in non-classical MVP, implying the need for routine ECG-Holter monitoring in their diagnosis for timely prevention of clinical arrhythmogenic complications.

  9. GAMMAGRAFÍA DE PERFUSIÓN MIOCÁRDICA EN MUJERES POSMENOPÁUSICAS CON ANGINA Y CORONARIAS EPICÁRDICAS ANGIOGRÁFICAMENTE NORMALES / Myocardial perfusion scintigraphy in postmenopausal women with angina and angiographically normal epicardial coronary

    Directory of Open Access Journals (Sweden)

    Sherien Sixto Fernández

    2011-03-01

    Full Text Available Introduction and Objectives: Microvascular angina is common in postmenopausal women. Myocardial ischemia was induced by stress testing, and reports have been published about the relationship between endothelial dysfunction and myocardial perfusion. The objective of this research was to determine whether myocardial ischemia can be evidenced by abnormalities in perfusion and function, as detected by myocardial scintigraphy in women with typical angina, normal coronary angiography and endothelial dysfunction. Methods: 59 women underwent lipid and endothelial function measurements by brachial artery ultrasound, in addition, a 24-hour ECG study (Holter. During the scintigraphy a stress-rest protocol was applied. Patients were divided into two groups according to presence (group I or absence (group II of myocardial perfusion defects. Results: 21 patients showed perfusion defects. 57 % of group I exhibited greater endothelial dysfunction. Only twelve patients showed reversible perfusion defects, and 75 % of the cases was associated with a reduction of post-stress left ventricular ejection fraction, greater than 5 %, and regional abnormalities of wall motion. Three patients in group I showed evidence of ischemia compared with four in Group II. Conclusions: The stress-induced ischemia was associated with a reduced post-stress ejection fraction and endothelial dysfunction in the studied women, and no ischemic changes in the Holter were found.

  10. Avaliação clínica e funcional tardia de arritmias em crianças operadas de Tetralogia de Fallot Evaluación clínica y funcional tardía de arritmias en niños operados de tetralogía de Fallot Late clinical and functional assessment of arrhythmias in children after repair of Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Maria Eulália Thebit Pfeiffer

    2010-09-01

    Full Text Available FUNDAMENTO: Arritmias cardíacas são a maior causa de morte súbita tardia em pacientes operados de Tetralogia de Fallot (TF. OBJETIVO: Avaliar a ocorrência de arritmias cardíacas em crianças e adolescentes operados de TF, associando-as aos aspectos clínicos e de exames complementares. MÉTODOS: Estudo transversal em 37 pacientes submetidos a cirurgia de TF no Instituto Estadual de Cardiologia Aloysio de Castro (RJ. Após revisão de prontuários e avaliação clínica, os pacientes foram submetidos a eletrocardiograma (ECG, ecocardiograma (Eco, Holter 24h (Holter e teste ergométrico (TE, sendo os resultados submetidos a análise estatística. RESULTADOS: Estudados 37 pacientes, 54% masculinos, idade 9,7 ± 3,5 anos, seguimento médio de 4,7 ± 1,9 anos. Alterações mais prevalentes: ECG: bloqueio de ramo direito (89%; Eco: insuficiência pulmonar grave (43%, estenose pulmonar leve (73%, hipertrofia ventricular direita (HVD moderada (57%. No TE, baixa capacidade de exercício (90%, déficit cronotrópico (40%, arritmias (20%. Ao Holter, 59% apresentaram arritmias: ventriculares 44%, supraventriculares 38% e ambas 24%, com predomínio de extrassístoles pouco frequentes e benignas. Cinco pacientes (15% apresentaram extrassístoles polimórficas. Houve associação entre arritmia ventricular e HVD moderada e grave (p=0,026 e também com gradiente ventrículo direito-artéria pulmonar (VD/AP > 45 mmHg (p=0,004. Através da Regressão Logística, o aumento do gradiente VD/AP foi fator preditivo independente para arritmia ventricular (p=0,017. CONCLUSÃO: Arritmias cardíacas foram um achado comum em grande parte de crianças e adolescentes após reparo cirúrgico de TF, porém pouco frequentes e benignas, na maioria dos casos. O gradiente pressórico VD-AP foi considerado forte preditor para arritmia ventricular.FUNDAMENTO: Arritmias cardíacas son la mayor causa de muerte súbita tardía en pacientes operados de Tetralogía de Fallot (TF

  11. Electrocardiogram Pattern Recognition and Analysis Based on Artificial Neural Networks and Support Vector Machines: A Review

    Directory of Open Access Journals (Sweden)

    Mario Sansone

    2013-01-01

    Full Text Available Computer systems for Electrocardiogram (ECG analysis support the clinician in tedious tasks (e.g., Holter ECG monitored in Intensive Care Units or in prompt detection of dangerous events (e.g., ventricular fibrillation. Together with clinical applications (arrhythmia detection and heart rate variability analysis, ECG is currently being investigated in biometrics (human identification, an emerging area receiving increasing attention. Methodologies for clinical applications can have both differences and similarities with respect to biometrics. This paper reviews methods of ECG processing from a pattern recognition perspective. In particular, we focus on features commonly used for heartbeat classification. Considering the vast literature in the field and the limited space of this review, we dedicated a detailed discussion only to a few classifiers (Artificial Neural Networks and Support Vector Machines because of their popularity; however, other techniques such as Hidden Markov Models and Kalman Filtering will be also mentioned.

  12. Sympathetic overactivity and arrhythmias in tetanus: electrocardiographic analysis Hiperatividade simpática e arritmias no tétano: análise eletrocardiográfica

    Directory of Open Access Journals (Sweden)

    Gustavo Trindade Henriques Filho

    2007-02-01

    Full Text Available As a result of the advances in the control of pulmonary insufficiency in tetanus, the cardiovascular system has increasingly been shown to be a determining factor in morbidity and mortality but detailed knowledge of the cardiovascular complications in tetanus is scanty. The 24h-Holter was carried out in order to detect arrhythmias and sympathetic overactivity in 38 tetanus patients admitted to an ICU. The SDNN Index (standard deviation from the normal R-to-R intervals, was useful in detecting adrenergic tonus, and ranged from 64.1 ± 27 in the more severe forms of tetanus to 125 ± 69 in the milder ones. Sympathetic overactivity occurred in 86.2% of the more severe forms of the disease, but was also detected in 33% of the milder forms. Half the patients had their sympathetic overactivity detected only by the Holter. The most frequent arrhythmias were isolated supraventricular (55.2% and ventricular (39.4% extrasystoles. There was no association of the arrhythmias with the clinical form of tetanus or with the presence of sympathetic overactivity. The present study demonstrated that major cardiovascular dysfunction, particularly sympathetic overactivity, occurs in all forms of tetanus, even in the milder ones. This has not been effectively detected with traditional monitoring in ICU and may not be properly treated.Com os avanços no controle da insuficiência respiratória no tétano, o sistema cardiovascular tem participado de forma crescente na morbidade e mortalidade da doença, mas o conhecimento dessas complicações é escasso. No intuito de detectar arritmias e hiperatividade simpática, o holter de 24 h foi utilizado em 38 pacientes com tétano admitidos numa UTI de doenças infecciosas. O índice SDNN (desvio standard dos intervalos normais R-a-R, foi útil na detecção do tônus adrenérgico, e variou de 64,1 ± 27 nas formas mais severas de tétano a 125 ± 69 nas formas mais leves. Hiperatividade simpática ocorreu em 86,2% das formas

  13. Clinical usefulness of 123I-MIBG myocardial spect in patients with cardiac sarcoidosis

    International Nuclear Information System (INIS)

    Kobayashi, Keiko; Hatsumi, Chie; Fujioka, Haruto

    1996-01-01

    This study was undertaken to assess whether 123 I-MIBG scintigraphy is useful to detect cardiac involvements of sarcoidosis. In 45 patients with sarcoidosis, dual SPECT with 123 I-MIBG and 201 Tl-Cl(Tl) were performed, and the findings were compared with electrocardiogram (ECG), 24 hour Holter ECG and ultrasound echocardiography. In order to evaluate cardiac involvements, Tl and MIBG extent score (E.S.) and severity score (S.S.) were calculated by a Bull's eye map in addition to visual evaluation. Abnormal findings were recognized in 8.9% of all subjects in echocardiography, in 22.2% of those in ECG and Holter ECG, in 40% of those in Tl scintigraphy, and in 64.4% of those in MIBG scintigraphy. All of the Tl and MIBG abnormalities were detected in left ventricles, especially at the basal septal wall. At the inferior wall, abnormalities were observed more frequently by MIBG than by Tl. Tl E.S., Tl S.S. and MIBG E.S. were significantly higher in 10 patients with abnormal ECG findings than in 35 patients with normal ECG findings. Also, all of 10 patients with abnormal ECG findings had abnormal MIBG image, but 3 of them showed normal Tl images. 11 of 35 patients with normal ECG findings showed abnormal Tl and MIBG images (group A), 8 of 35 patients showed normal Tl images and abnormal MIBG images (group B), and 16 of 35 patients showed normal Tl and MIBG images (group C). MIBG S.S. of group A (11.3±7.8) was significantly higher than that of group B (5.3±3.1) or group C (2.6±3.2). Furthermore, in group A, MIBG S.S. was significantly higher than Tl S.S. (5.5±2.8). In a case of normal ECG with abnormal MIBG images, we seriously suspect cardiac involvements and recommend repeated Holter ECG tests as necessary in order to detect critical arrythmia. MIBG scintigraphy appeared to be a sensitive and useful method for the early detection of cardiac sarcoidosis. (J.P.N.)

  14. Further contribution to the development of nuclear stethoscopic techniques

    International Nuclear Information System (INIS)

    Horvath, M.; Nemeth, L.; Kantor, E.; Kiss, J.; Bocsa, Z.; Sziberth, P.; Karman, M.

    1991-01-01

    After the introduction of radiocardiography (RCG) function analysis, the method has gradually been improved by applying scintillation probes, semiconductor detectors and computer evaluation. Miniature semiconductor detectors were fixed onto the chest, the detection efficiency and energy resolution was clarified to further improve the RCG technique. Various semiconductor devices were tested and compared. The RCG was combined with Holter monitoring and ECG. Photodiode RCG was extended to ergometric measurements. These new improvements were evaluated. (R.P.) 8 refs.; 8 figs

  15. HEREDITARY INTRAVENTRICULAR CONDUCTION DISORDERS IN THE FAMILY FROM KRASNOYARSK

    Directory of Open Access Journals (Sweden)

    A. A. Chernova

    2011-01-01

    Full Text Available Pedigree of the family from Krasnoyarsk city with hereditary disorders of intracardiac conduction was studied. The diagnosis of each family member was verified by electrocardiography (ECG, echocardiography , bicycle ergometry , ECG Holter monitoring. The family 10-year follow-up showed familial aggregation of intracardiac conduction disorders in grandson, niece, son of the proband niece, ie, in the III-degree relatives. Family history of III-degree relatives with intracardiac conduction disorders and discordant pathology is identified.

  16. A Psychological Factor Affecting a Cardiac Condition in a Psychotherapist

    OpenAIRE

    R Waxman; K Khorasani; A Lenny; S Bhalerao

    2009-01-01

    It has been established that intense emotions can affect the development and course of cardiac arrhythmias. This study sought to convey that a lack of expression of emotion can also have an effect on arrhythmias. A psychotherapist with Idiopathic Ventricular Fibrillation and an Implantable Cardioverter Defibrillator measured his rate of Premature Ventricular Contractions using a Holter monitor during three separate six-week periods and in three domains: A) work days vs. off days, B) a 27 hour...

  17. Arrhythmia as a cardiac manifestation in MELAS syndrome.

    Science.gov (United States)

    Thomas, Tamara; Craigen, William J; Moore, Ryan; Czosek, Richard; Jefferies, John L

    2015-09-01

    A 44-year-old female with a diagnosis of mitochondrial myopathy, encephalopathy and stroke-like episodes (MELAS) syndrome had progressive left ventricular hypertrophy (LVH) on echocardiogram. A Holter monitor demonstrated episodes of non-sustained atrial tachycardia, a finding not been previously described in this population. This unique case of MELAS syndrome demonstrates the known associated cardiac manifestation of LVH and the new finding of atrial tachycardia which may represent the potential for subclinical arrhythmia in this population.

  18. Heart rate turbulence and variability in patients with ventricular arrhythmias

    Directory of Open Access Journals (Sweden)

    Diego Tarricone

    2009-08-01

    Full Text Available Background: To evaluate the changes in autonomic neural control mechanisms before malignant ventricular arrhythmias, we measured heart rate variability (HRV and heart rate turbulence (HRT in patients with ventricular tachycardia or fibrillation (Group I; n=6, non sustained ventricular tachycardia (Group II; n=32, frequent premature ventricular beats (Group III; n=26 and with ICD implantation (Group IV; n=11. Methods: Time domain parameters of HRV and turbulence onset (TO and slope (TS were calculated on 24 hour Holter recordings. Normal values were: SDNN > 70 msec for HRV, TO <0% and TS >2.5 msec/RR-I for HRT. Results: Whereas SDNN was within normal range and similar in all study groups, HRT parameters were significantly different in patients who experienced VT/VF during Holter recording. Abnormal TO and/or TS were present in 100% of Group I patients and only in about 50% of Group II and IV. On the contrary, normal HRT parameters were present in 40-70% of Group II, III and IV patients and none of Group I. Conclusions: These data suggest that HRT analysis is more suitable than HRV to detect those transient alterations in autonomic control mechanisms that are likely to play a major trigger role in the genesis of malignant cardiac arrhythmias. (Heart International 2007; 3: 51-7

  19. Useful clinical features for the selection of ideal patients with strial fibrillation for mapping and catheter ablation

    Directory of Open Access Journals (Sweden)

    Mehta Niraj

    2002-01-01

    Full Text Available OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1 antiarrhythmic drugs, 2 symptoms of low cardiac output, and 3 intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation, catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein. One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.

  20. Noninvasive diagnosis of allograft vascular disease after heart transplantation

    Directory of Open Access Journals (Sweden)

    Fernando Bacal

    2001-01-01

    Full Text Available OBJECTIVE: To determine the predictive values of noninvasive tests for the detection of allograft vascular disease. METHODS: We studied 39 patients with mean ages of 48±13 years and a follow-up period of 86±13 months. The diagnosis of allograft vascular disease was made by cine-coronary arteriography, and it was considered as positive if lesions existed that caused > or = 50% obstruction of the lumen. Patients underwent 24h Holter monitoring, thallium scintigraphy, a treadmill stress test, and dobutamine stress echocardiography. Sensitivity, specificity, and positive and negative predictive values were determined in percentages for each method, as compared with the cine-coronary arteriography results. RESULTS: Allograft vascular disease was found in 15 (38% patients. The Holter test showed 15.4% sensitivity, 95.5% specificity. For the treadmill stress test, sensitivity was 10%, specificity was 100%. When thallium scintigraphy was used, sensitivity was 40%, specificity 95.8%. On echocardiography with dobutamine, we found a 63.6% sensitivity, 91.3% specificity. When the dobutamine echocardiogram was associated with scintigraphy, sensitivity was 71.4%, specificity was 87%. CONCLUSION: In this group of patients, the combination of two noninvasive methods (dobutamine echocardiography and thallium scintigraphy may be a good alternative for the detection of allograft vascular disease in asymptomatic patients with normal ventricular function.

  1. Omega-3 Fatty Acid Supplementation Improves Heart Rate Variability in Obese Children

    Directory of Open Access Journals (Sweden)

    Christoph Baumann

    2018-01-01

    Full Text Available Obese children and adolescents are at high risk of developing cardiovascular diseases later in life. We hypothesized that cardiovascular prophylaxis with omega-3 fatty acids could benefit them. In our study, 20 children and adolescents (mean body mass index percentile: 99.1; mean age: 11.0 years underwent two ambulatory 24 h Holter electrocardiography (ECG recordings (before and after at least 3 months of omega-3 fatty acid supplementation. Time domain heart rate variability (HRV and heart rate (HR were examined for these patients. As a control, we used 24 h Holter ECG recordings of 94 nonobese children and adolescents. Time domain HRV parameters, which are indicators of vagal stimulation, were significantly lower in obese patients than in healthy controls, but HR was higher (standard deviation of the normal-to-normal [SDNN] interbeat intervals: −34.02%; root mean square of successive differences [RMSSD] between normal heartbeats: −40.66%; percentage of consecutive RR intervals [pNN50]: −60.24%; HR: +13.37%. After omega-3 fatty acid supplementation, time domain HRV parameters and HR of obese patients were similar to the values of healthy controls (SDNN interbeat intervals: −21.73%; RMSSD: −19.56%; pNN50: −25.59%; HR: +3.94%. Therefore, omega-3 fatty acid supplementation may be used for cardiovascular prophylaxis in obese children and adolescents.

  2. Circadian variation in dominant atrial fibrillation frequency in persistent atrial fibrillation

    International Nuclear Information System (INIS)

    Sandberg, Frida; Stridh, Martin; Sörnmo, Leif; Bollmann, Andreas; Husser, Daniela

    2010-01-01

    Circadian variation in atrial fibrillation (AF) frequency is explored in this paper by employing recent advances in signal processing. Once the AF frequency has been estimated and tracked by a hidden Markov model approach, the resulting trend is analyzed for the purpose of detecting and characterizing the presence of circadian variation. With cosinor analysis, the results show that the short-term variations in the AF frequency exceed the variation that may be attributed to circadian. Using the autocorrelation method, circadian variation was found in 13 of 18 ambulatory ECG recordings (Holter) acquired from patients with long-standing persistent AF. Using the ensemble correlation method, the highest AF frequency usually occurred during the afternoon, whereas the lowest usually occurred during late night. It is concluded that circadian variation is present in most patients with long-standing persistent AF though the short-term variation in the AF frequency is considerable and should be taken into account

  3. Lanchester-Type Models of Warfare. Volume II

    Science.gov (United States)

    1980-10-01

    ii7 L HOWES and THRALL (1972) ,HT n HTY HT m HTX jini ijl HOLTER (1973) and ANDERSON (1979) CHA HAx Y tAs in the preceding table, SPUDICH (1968) - the...detail can one afford? A recent U. S. General Accounting Office ( GAO ) report [150, pp. 28-29] points out that there is a strong inconsistency between...further details). 65. A recent U. S. Getueral Accounting Office ( GAO ) [1501 study has emphasized that empirical study is necessary to strengthen the

  4. A modified van der Pol equation with delay in a description of the heart action

    OpenAIRE

    Zduniak Beata; Bodnar Marek; Foryś Urszula

    2014-01-01

    In this paper, a modified van der Pol equation is considered as a description of the heart action. This model has a number of interesting properties allowing reconstruction of phenomena observed in physiological experiments as well as in Holter electrocardiographic recordings. Our aim is to study periodic solutions of the modified van der Pol equation and take into consideration the influence of feedback and delay which occur in the normal heart action mode as well as in pathological modes. U...

  5. Primary cardiac tumor presenting as left ventricular outflow tract obstruction and complex arrhythmia.

    Science.gov (United States)

    Fries, R; Achen, S; O'Brien, M T; Jackson, N D; Gordon, S

    2017-10-01

    An adult female mixed breed dog presented for recurrent collapsing episodes over several weeks. Holter evaluation revealed periods of sinus arrest and echocardiography identified a soft tissue mass with subsequent severe dynamic obstruction of the left ventricular outflow tract. The patient was euthanized five days after presentation for severe dyspnea. Necropsy revealed an irregular mass circumferentially lining the left ventricular outflow tract as well as multiple myocardial metastases. The final diagnosis was an undifferentiated pleomorphic endocardial sarcoma. Published by Elsevier B.V.

  6. Family, Socialization and Migration in Norwegian-Pakistani Families: A Study of the First and the Second Generation

    OpenAIRE

    Shakari, Yasmine

    2013-01-01

    Summary Author s name: Yasmine Shakari Title: Family, Socialization and Migration in Norwegian-Pakistani Families: A Study of the First and the Second Generation Supervisor: Øystein Gullvåg Holter Co-supervisor: Thomas Walle Aim of study: This thesis seeks to obtain knowledge about 1) how the first generation of Norwegian-Pakistanis were raised in Pakistan in terms of socialization of gender roles, 2) how the second generation of Norwegian-Pakistanis have been raised here in Norway, and 3) if...

  7. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cristina Soguero-Ruiz

    2018-03-01

    Full Text Available Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT, and a complex-domain (heart rate variability (HRV. Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT. The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain.

  8. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Science.gov (United States)

    Mora-Jiménez, Inmaculada; Ramos-López, Javier; Quintanilla Fernández, Teresa; García-García, Antonio; Díez-Mazuela, Daniel; García-Alberola, Arcadi

    2018-01-01

    Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT)), and a complex-domain (heart rate variability (HRV)). Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages) and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT). The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain. PMID:29494497

  9. Syncope in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    I. V. Leontyeva

    2014-01-01

    Full Text Available Seventy children aged 7 to 17 years with hypertrophic cardiomyopathy (HCM were examined; among them there were 11 syncope patients and 5 presyncope patients. The screening program included standard electrocardiography (ECG, Doppler echocardiogra-phy, 24-hour Holter ECG monitoring, and an incremental exercise testing (Bruce treadmill test. The markers of myocardial electrical instability were determined. In the children with HCM, syncope was established to be heterogeneous; it had an arrhythmogenic origin and, in most cases, occurred in the presence of tachyarrhythmia (44% or bradyarrythmia (25%; its vasovagal genesis was probable in one third of the examinees. The children with syncope were typified by the asymmetric, obstructive form of HCM, at the same tone there was most commonly left ventricular hypertrophy concurrent with left atrial enlargement. 24-hour Holter monitoring showed that bradycardia was prevalent in the patients, 3 patients were found to have more than 2-second cardiac rhythm pauses caused by second-degree atrioventricular block in 1 case or by sick sinus syndrome in 2. Nonsustained ventricular tachycardia was noted in two patients. The children with syncope were typified by the signs of myocardial electrical instability as a reduction in the early phase of heart rate turbulence and by impaired QT/RR interval adaptation as hyperadaptation. The paper presents the developed management tactics for children with syncope and indications for the implantation of a cardioverter defibrillator, a pacemaker, or an ECG loop recorder.

  10. Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.

    Science.gov (United States)

    Kollias, Anastasios; Destounis, Antonios; Kalogeropoulos, Petros; Kyriakoulis, Konstantinos G; Ntineri, Angeliki; Stergiou, George S

    2018-07-01

    This study assessed the diagnostic accuracy of a novel 24-hour ambulatory blood pressure (ABP) monitor (Microlife WatchBP O3 Afib) with implemented algorithm for automated atrial fibrillation (AF) detection during each ABP measurement. One hundred subjects (mean age 70.6±8.2 [SD] years; men 53%; hypertensives 85%; 17 with permanent AF; 4 paroxysmal AF; and 79 non-AF) had simultaneous 24-hour ABP monitoring and 24-hour Holter monitoring. Among a total of 6410 valid ABP readings, 1091 (17%) were taken in ECG AF rhythm. In reading-to-reading ABP analysis, the sensitivity, specificity, and accuracy of ABP monitoring in detecting AF were 93%, 87%, and 88%, respectively. In non-AF subjects, 12.8% of the 24-hour ABP readings indicated false-positive AF, of whom 27% were taken during supraventricular premature beats. There was a strong association between the proportion of false-positive AF readings and that of supraventricular premature beats ( r =0.67; P ABP monitoring had 100%/85% sensitivity/specificity (area under the curve 0.91; P ABP monitor with AF detector has high sensitivity and moderate specificity for AF screening during routine ABP monitoring. Thus, in elderly hypertensives, a 24-hour ABP recording with at least 26% of the readings suggesting AF indicates a high probability for AF diagnosis and should be regarded as an indication for performing 24-hour Holter monitoring. © 2018 American Heart Association, Inc.

  11. ECG-derived Cheyne-Stokes respiration and periodic breathing in healthy and hospitalized populations.

    Science.gov (United States)

    Tinoco, Adelita; Drew, Barbara J; Hu, Xiao; Mortara, David; Cooper, Bruce A; Pelter, Michele M

    2017-11-01

    Cheyne-Stokes respiration (CSR) has been investigated primarily in outpatients with heart failure. In this study we compare CSR and periodic breathing (PB) between healthy and cardiac groups. We compared CSR and PB, measured during 24 hr of continuous 12-lead electrocardiographic (ECG) Holter recording, in a group of 90 hospitalized patients presenting to the emergency department with symptoms suggestive of acute coronary syndrome (ACS) to a group of 100 healthy ambulatory participants. We also examined CSR and PB in the 90 patients presenting with ACS symptoms, divided into a group of 39 (43%) with confirmed ACS, and 51 (57%) with a cardiac diagnosis but non-ACS. SuperECG software was used to derive respiration and then calculate CSR and PB episodes from the ECG Holter data. Regression analyses were used to analyze the data. We hypothesized SuperECG software would differentiate between the groups by detecting less CSR and PB in the healthy group than the group of patients presenting to the emergency department with ACS symptoms. Hospitalized patients with suspected ACS had 7.3 times more CSR episodes and 1.6 times more PB episodes than healthy ambulatory participants. Patients with confirmed ACS had 6.0 times more CSR episodes and 1.3 times more PB episodes than cardiac non-ACS patients. Continuous 12-lead ECG derived CSR and PB appear to differentiate between healthy participants and hospitalized patients. © 2017 Wiley Periodicals, Inc.

  12. Concurrent measurement of "real-world" stress and arousal in individuals with psychosis: assessing the feasibility and validity of a novel methodology.

    Science.gov (United States)

    Kimhy, David; Delespaul, Philippe; Ahn, Hongshik; Cai, Shengnan; Shikhman, Marina; Lieberman, Jeffrey A; Malaspina, Dolores; Sloan, Richard P

    2010-11-01

    Psychosis has been repeatedly suggested to be affected by increases in stress and arousal. However, there is a dearth of evidence supporting the temporal link between stress, arousal, and psychosis during "real-world" functioning. This paucity of evidence may stem from limitations of current research methodologies. Our aim is to the test the feasibility and validity of a novel methodology designed to measure concurrent stress and arousal in individuals with psychosis during "real-world" daily functioning. Twenty patients with psychosis completed a 36-hour ambulatory assessment of stress and arousal. We used experience sampling method with palm computers to assess stress (10 times per day, 10 AM → 10 PM) along with concurrent ambulatory measurement of cardiac autonomic regulation using a Holter monitor. The clocks of the palm computer and Holter monitor were synchronized, allowing the temporal linking of the stress and arousal data. We used power spectral analysis to determine the parasympathetic contributions to autonomic regulation and sympathovagal balance during 5 minutes before and after each experience sample. Patients completed 79% of the experience samples (75% with a valid concurrent arousal data). Momentary increases in stress had inverse correlation with concurrent parasympathetic activity (ρ = -.27, P feasibility and validity of our methodology in individuals with psychosis. The methodology offers a novel way to study in high time resolution the concurrent, "real-world" interactions between stress, arousal, and psychosis. The authors discuss the methodology's potential applications and future research directions.

  13. VLSI in medicine

    CERN Document Server

    Einspruch, Norman G

    1989-01-01

    VLSI Electronics Microstructure Science, Volume 17: VLSI in Medicine deals with the more important applications of VLSI in medical devices and instruments.This volume is comprised of 11 chapters. It begins with an article about medical electronics. The following three chapters cover diagnostic imaging, focusing on such medical devices as magnetic resonance imaging, neurometric analyzer, and ultrasound. Chapters 5, 6, and 7 present the impact of VLSI in cardiology. The electrocardiograph, implantable cardiac pacemaker, and the use of VLSI in Holter monitoring are detailed in these chapters. The

  14. Holter monitoring of central and peripheral temperature: possible uses and feasibility study in outpatient settings.

    Science.gov (United States)

    Varela, Manuel; Cuesta, David; Madrid, Juan Antonio; Churruca, Juan; Miro, Pau; Ruiz, Raul; Martinez, Carlos

    2009-08-01

    Conventional clinical thermometry has important limitations. A continuous monitoring of temperature may offer significant advantages, including the use of chronobiological and complexity analysis of temperature profile and eventually the identification of a "pre-febrile" pattern. We present a clinical model designed to measure, store and/or transmit in real time a central and a peripheral temperature reading. The results of its use in a healthy, free-living population is reported. Thirty subjects (15 women, 15 men, 20-70 years old), were monitored for 24 h while following their normal life. Temperatures were recorded every minute at the external auditory channel (EAC) and on the skin, at the intersection of the 5th intercostal space and the anterior axillary line. A Cosinor analysis and Approximate Entropy (ApEn) (m = 2, r = 0.15*SD, N = 180) were calculated for both temperatures. Median temperature was 35.55 degrees C [interquartile range (IR) 0.77 degrees C] in the external auditory channel (EAC) and 34.62 degrees C (IR 1.61) in the specified skin location. Median gradient between AEC and skin was 0.93 (IR 1.57). A circadian rhythm was present both in EAC and skin temperature, with a mean amplitude of 0.44 degrees C and an acrophase at 21:02 for the EAC and 0.70 degrees C and 00:42 for the skin. During the night there was a sizable increase in peripheral temperature, with a decrease in gradient and a loss of complexity in the temperature profile, most significantly in the peripheral temperature. Continuous monitoring of central and peripheral temperature may be a helpful tool in both ambulatory and admitted patients and may offer new approaches in clinical thermometry.

  15. Long-term biatrial recordings in post-operative atrial fibrillation.

    Science.gov (United States)

    Masè, M; Graffigna, A; Sinelli, S; Pallaoro, G; Nollo, G; Ravelli, F

    2010-01-01

    Although atrial fibrillation (AF) is a common complication of cardiac surgery, its pathophysiology remains unclear. The study of post-operative AF demands for the recording of cardiac electrical activity in correspondence of AF onset and progression. Long-term recordings in post-surgery patients could provide this information, but, to date, have been limited to surface signals, which precludes a characterization of the arrhythmic triggers and substrate. In this study we demonstrate the feasibility of a continuous long-term recording of atrial electrical activities from the right and left atria in post-surgery patients. Local atrial epicardial electrograms are acquired by positioning temporary pacing wires in the right and left atria at the end of the intervention, while three day recordings are obtained by a digital holter recorder, adapted to epicardial signal features. The capability of the system to map local atrial activity and the possibility to obtain quantitative information on atrial rate and synchronization from the processed epicardial signals are proven in representative examples. The quantitative description of local atrial properties opens new perspective in the investigation of post-surgery AF.

  16. Smartphone electrographic monitoring for atrial fibrillation in acute ischemic stroke and transient ischemic attack.

    Science.gov (United States)

    Tu, Hans T; Chen, Ziyuan; Swift, Corey; Churilov, Leonid; Guo, Ruibing; Liu, Xinfeng; Jannes, Jim; Mok, Vincent; Freedman, Ben; Davis, Stephen M; Yan, Bernard

    2017-10-01

    Rationale Paroxysmal atrial fibrillation is a common and preventable cause of devastating strokes. However, currently available monitoring methods, including Holter monitoring, cardiac telemetry and event loop recorders, have drawbacks that restrict their application in the general stroke population. AliveCor™ heart monitor, a novel device that embeds miniaturized electrocardiography (ECG) in a smartphone case coupled with an application to record and diagnose the ECG, has recently been shown to provide an accurate and sensitive single lead ECG diagnosis of atrial fibrillation. This device could be used by nurses to record a 30-s ECG instead of manual pulse taking and automatically provide a diagnosis of atrial fibrillation. Aims To compare the proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring with current standard practice. Sample size 296 Patients. Design Consecutive ischemic stroke and transient ischemic attack patients presenting to participating stroke units without known atrial fibrillation will undergo intermittent AliveCor™ ECG monitoring administered by nursing staff at the same frequency as the vital observations of pulse and blood pressure until discharge, in addition to the standard testing paradigm of each participating stroke unit to detect paroxysmal atrial fibrillation. Study outcome Proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring compared to 12-lead ECG, 24-h Holter monitoring and cardiac telemetry. Discussion Use of AliveCor™ heart monitor as part of routine stroke unit nursing observation has the potential to be an inexpensive non-invasive method to increase paroxysmal atrial fibrillation detection, leading to improvement in stroke secondary prevention.

  17. Diagnostic Dilemma of Cardiac Syncope in Pediatric Patients

    Directory of Open Access Journals (Sweden)

    Ranya A Hegazy

    2008-02-01

    Full Text Available Aims Syncope is defined as temporary loss of consciousness and postural tone resulting from an abrupt transient decrease in cerebral blood flow. The present work aimed at determining how diagnostic tests are used in the evaluation of pediatric syncope at a tertiary pediatric referral center and to report on the utility and the yield of these tests.Settings and Design Retrospective study conducted at a tertiary referral arrhythmolology serviceMethods and Material The clinical charts of 234 pediatric patients presenting with a primary complaint of syncope with an average age of 7.48 ± 3.82(3.5-16 years were reviewed by the investigators.Statistical analysis used Statistical Package of social science (SPSS version 9,0 was used for analysis of data.Results The commonest trigger for syncope in the study population was early following exercise (n=65 and the commonest prodrome was palpitation, noted in 25 patients. A murmur was present in 19 of our patients (8.3% while 10.7% (n=25 had abnormal ECGs. Of the 106 echocardiograms done, 14 (13.2% were abnormal. Only two of them were missed by ECG. All patients were offered ambulatory 24 hour ECG. One patient with sick sinus syndrome was diagnosed only with Holter.Conclusions Clues to the presence of cardiac syncope may include acute onset of syncope, frequent episodes, low difference between blood pressure readings in supine and erect positions (after standing for 2 minutes and most importantly an abnormal 12 lead ECG. Transthoracic echo and Holter monitoring have low yield in pediatric syncope.

  18. Early diagnosis of interferon-induced myocardial disorder in patients with chronic hepatitis C. Evaluation by myocardial imaging with 123I-BMIPP

    International Nuclear Information System (INIS)

    Kondo, Yuki; Yukinaka, Michiko; Nomura, Masahiro; Nakaya, Yutaka; Ito, Susumu

    2000-01-01

    Interferon (IFN) therapy for chronic hepatitis C is sometimes associated with cardiac complications. In the present study, we performed myocardial imaging with 123 I-labeled β-methyl-p-iodophenylpentadecanoic acid ( 123 I-BMIPP) in order to evaluate myocardial disorders caused by IFN. We studied 40 healthy subjects (H group) and 25 patients with chronic hepatitis C who had been treated with IFN (IFN group). A Holter electrocardiogram (ECG) was performed and the autonomic nervous function was assessed by analyzing the spectral variability and 1/f fluctuation of heart rate. Myocardial planner imaging with 123 I-BMIPP was performed to obtain the time activity curve for 20 min immediately after administration of 123 I-BMIPP (dynamic study). Early and delayed myocardial single photon emission computed tomography (SPECT) images were expressed as Bull's eyes and the myocardium was divided into four segments to calculate the washout rate for each segment on early and late SPECT images (early and late SPECT study). No significant differences in autonomic nervous function were observed between the two groups in heart rate variability. In a dynamic study, the reduction rate from the time activity curve was significantly higher in the IFN group compared with the H group (reduction rate, IFN group, 5.3±3.7% vs H group, 1.2±3.3%; P 123 I-BMIPP myocardial scintigraphy examination several months after IFN therapy. These results indicate that metabolic disorders of fatty acids caused by IFN therapy can be detected before abnormalities are observed by Holter-ECG or echocardiography. (author)

  19. Early diagnosis of interferon-induced myocardial disorder in patients with chronic hepatitis C: evaluation by myocardial imaging with 123I-BMIPP.

    Science.gov (United States)

    Kondo, Y; Yukinaka, M; Nomura, M; Nakaya, Y; Ito, S

    2000-01-01

    Interferon (IFN) therapy for chronic hepatitis C is sometimes associated with cardiac complications. In the present study, we performed myocardial imaging with 123I-labeled beta-methyl-p-iodophenylpentadecanoic acid (123I-BMIPP) in order to evaluate myocardial disorders caused by IFN. We studied 40 healthy subjects (H group) and 25 patients with chronic hepatitis C who had been treated with IFN (IFN group). A Holter electrocardiogram (ECG) was performed and the autonomic nervous function was assessed by analyzing the spectral variability and 1/f fluctuation of heart rate. Myocardial planner imaging with 123I-BMIPP was performed to obtain the time activity curve for 20min immediately after administration of 123I-BMIPP (dynamic study). Early and delayed myocardial single photon emission computed tomography (SPECT) images were expressed as Bull's eyes and the myocardium was divided into four segments to calculate the washout rate for each segment on early and late SPECT images (early and late SPECT study). No significant differences in autonomic nervous function were observed between the two groups in heart rate variability. In a dynamic study, the reduction rate from the time activity curve was significantly higher in the IFN group compared with the H group (reduction rate, IFN group, 5.3 +/- 3.7% vs H group, 1.2 +/- 3.3%; P acids caused by IFN was reversed on the second 123I-BMIPP myocardial scintigraphy examination several months after IFN therapy. These results indicate that metabolic disorders of fatty acids caused by IFN therapy can be detected before abnormalities are observed by Holter-ECG or echocardiography.

  20. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    Science.gov (United States)

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length 1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  1. A Novel 12-Lead ECG T-Shirt with Active Electrodes

    Directory of Open Access Journals (Sweden)

    Anna Boehm

    2016-11-01

    Full Text Available We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403. The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.

  2. Low frequency of cardniac arrhythmias and lack of structural heart disease in medically-naïve acromegaly patients: a prospective study at baseline and after 1 year of somatostatin analogs treatment.

    Science.gov (United States)

    Warszawski, Leila; Kasuki, Leandro; Sá, Rodrigo; Dos Santos Silva, Cintia Marques; Volschan, Isabela; Gottlieb, Ilan; Pedrosa, Roberto Coury; Gadelha, Mônica R

    2016-12-01

    The incidence of arrhythmias may be increased in acromegaly, but the pathophysiologic mechanisms involved are still unclear, and it has never been correlated with structural heart changes analyzed by the gold-standard method cardiac magnetic resonance (CMR). Evaluate the frequency of arrhythmias in drug-naïve acromegaly patients at baseline and after 1 year of somatostatin analogs (SA) treatment and to correlate the occurrence of arrhythmias with the presence of structural heart changes. Consecutive drug-naïve acromegaly patients were recruited. The occurrence of arrhythmias and structural heart changes were studied through 24-h Holter and CMR, respectively, at baseline and after 1-year SA treatment. Thirty-six patients were studied at baseline and 28 were re-evaluated after 1 year of SA treatment. There were 13 females and median age was 48 years (20-73 years). Nine patients (32 %) were controlled after treatment. No sustained arrhythmias were reported in the 24-h Holter. No arrhythmia-related symptoms were observed. Only two patients presented left ventricular hypertrophy and three patients presented fibrosis at baseline. There was no correlation of the left ventricular mass with the number of episodes of arrhythmias and they were not more prevalent in the patients presenting cardiac fibrosis. We found no sustained arrhythmias and a lack of arrhythmia-related symptoms at baseline and after 1 year of SA treatment in a contemporary cohort of acromegaly patients that also present a low frequency of structural heart changes, indicating that these patients may have a lower frequency of heart disease than previously reported.

  3. Are Changes in Heart Rate Variability During Hypoglycemia Confounded by the Presence of Cardiovascular Autonomic Neuropathy in Patients with Diabetes?

    DEFF Research Database (Denmark)

    Cichosz, Simon Lebech; Frystyk, Jan; Tarnow, Lise

    2017-01-01

    BACKGROUND: We have recently shown how the combination of information from continuous glucose monitor (CGM) and heart rate variability (HRV) measurements can be used to construct an algorithm for prediction of hypoglycemia in both bedbound and active patients with type 1 diabetes (T1D). Questions...... with CGM and a Holter device while they performed normal daily activities. CAN was diagnosed using two cardiac reflex tests: (1) deep breathing and (2) orthostatic hypotension and end organ symptoms. Early CAN was defined as the presence of one abnormal reflex test and severe CAN was defined as two...

  4. Prosthetic Valve Endocarditis - Successful Management With Antimicrobial Treatment

    Directory of Open Access Journals (Sweden)

    Ashokan Nambiar C

    2015-07-01

    Full Text Available Middle aged male was admitted with high fever, rigor and chills of 2 days duration. He was seen in the clinic two years back for syncope. He gave history of Mitral (Starr-Edward and Aortic (Medtronic valve replacement ten years earlier from another center and was on regular anticoagulation with dose-adjusted acenocoumarol. On evaluation he had normal prosthetic valve function by trans-thoracic echo, but Holter monitoring showed Paroxysmal Atrial Fibrillation. He had mild wall motion abnormalities and left ventricular dysfunction suggestive of coronary artery disease also and was put on additional Metoprolol.

  5. Consumption of Caffeinated Products and Cardiac Ectopy.

    Science.gov (United States)

    Dixit, Shalini; Stein, Phyllis K; Dewland, Thomas A; Dukes, Jonathan W; Vittinghoff, Eric; Heckbert, Susan R; Marcus, Gregory M

    2016-01-26

    Premature cardiac contractions are associated with increased morbidity and mortality. Though experts associate premature atrial contractions (PACs) and premature ventricular contractions (PVCs) with caffeine, there are no data to support this relationship in the general population. As certain caffeinated products may have cardiovascular benefits, recommendations against them may be detrimental. We studied Cardiovascular Health Study participants with a baseline food frequency assessment, 24-hour ambulatory electrocardiography (Holter) monitoring, and without persistent atrial fibrillation. Frequencies of habitual coffee, tea, and chocolate consumption were assessed using a picture-sort food frequency survey. The main outcomes were PACs/h and PVCs/hour. Among 1388 participants (46% male, mean age 72 years), 840 (61%) consumed ≥1 caffeinated product per day. The median numbers of PACs and PVCs/h and interquartile ranges were 3 (1-12) and 1 (0-7), respectively. There were no differences in the number of PACs or PVCs/h across levels of coffee, tea, and chocolate consumption. After adjustment for potential confounders, more frequent consumption of these products was not associated with ectopy. In examining combined dietary intake of coffee, tea, and chocolate as a continuous measure, no relationships were observed after multivariable adjustment: 0.48% fewer PACs/h (95% CI -4.60 to 3.64) and 2.87% fewer PVCs/h (95% CI -8.18 to 2.43) per 1-serving/week increase in consumption. In the largest study to evaluate dietary patterns and quantify cardiac ectopy using 24-hour Holter monitoring, we found no relationship between chronic consumption of caffeinated products and ectopy. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  6. Excessive Premature Atrial Complexes and the Risk of Recurrent Stroke or Death in an Ischemic Stroke Population.

    Science.gov (United States)

    Vinther, Kristina H; Tveskov, Claus; Möller, Sören; Auscher, Soren; Osmanagic, Armin; Egstrup, Kenneth

    2017-06-01

    Our aim was to investigate the association of premature atrial complexes and the risk of recurrent stroke or death in patients with ischemic stroke in sinus rhythm. In a prospective cohort study, we used 24-hour Holter recordings to evaluate premature atrial complexes in patients consecutively admitted with ischemic strokes. Excessive premature atrial complexes were defined as >14 premature atrial complexes per hour and 3 or more runs of premature atrial complexes per 24 hours. During follow-up, 48-hour Holter recordings were performed after 6 and 12 months. Among patients in sinus rhythm, the association of excessive premature atrial complexes and the primary end point of recurrent stroke or death were estimated in both crude and adjusted Cox proportional hazards models. We further evaluated excessive premature atrial complexes contra atrial fibrillation in relation to the primary end point. Of the 256 patients included, 89 had atrial fibrillation. Of the patients in sinus rhythm (n = 167), 31 had excessive premature atrial complexes. During a median follow-up of 32 months, 50 patients (30% of patients in sinus rhythm) had recurrent strokes (n = 20) or died (n = 30). In both crude and adjusted models, excessive premature atrial complexes were associated with the primary end point, but not with newly diagnosed atrial fibrillation. Compared with patients in atrial fibrillation, those with excessive premature atrial complexes had similarly high risks of the primary end point. In patients with ischemic stroke and sinus rhythm, excessive premature atrial complexes were associated with a higher risk of recurrent stroke or death. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. Exercise-Induced Ventricular Fibrillation: Seven Years Follow-Up

    Directory of Open Access Journals (Sweden)

    Gökmen Gemici

    2011-11-01

    Full Text Available We present a 7-year follow-up of a 55-year-old male who experienced ventricular fibrillation during the recovery period of exercise testing and refused implantation of an ICD. Normal left ventricular systolic function was found on echocardiographic examination, and coronary angiography revealed only a side branch disease with a vessel diameter of less than 2 millimeters. The patient was discharged on metoprolol and ASA in addition to his previous treatment with lisinopril and simvastatin. Outpatient cardiac evaluation by repeated 24-hour ECG monitorizations (Holter revealed normal findings. On follow up visits every six months for the past seven years, the patient was found to be asymptomatic.

  8. A case of short-coupled premature ventricular beat-induced ventricular fibrillation with early repolarization in the inferolateral leads

    Directory of Open Access Journals (Sweden)

    Hidekazu Kondo, MD

    2015-02-01

    Full Text Available This case report describes a 19-year-old man with early repolarization (ER in the inferolateral leads and a normal QT interval who survived a cardiac arrest that was likely related to polymorphic ventricular tachycardia (VT. Electrocardiograms (ECGs also showed unifocal premature ventricular beats (PVBs with a relatively narrow QRS duration. A Holter ECG documented occasional short-coupled PVBs following non-sustained VTs. Pharmacological stress testing was also performed to assess the effects of anti-arrhythmic drugs on ER (the J wave and PVBs. We performed successful radiofrequency catheter ablation to prevent the recurrence of ventricular fibrillation after cardioverter-defibrillator implantation.

  9. A modified van der Pol equation with delay in a description of the heart action

    Directory of Open Access Journals (Sweden)

    Zduniak Beata

    2014-12-01

    Full Text Available In this paper, a modified van der Pol equation is considered as a description of the heart action. This model has a number of interesting properties allowing reconstruction of phenomena observed in physiological experiments as well as in Holter electrocardiographic recordings. Our aim is to study periodic solutions of the modified van der Pol equation and take into consideration the influence of feedback and delay which occur in the normal heart action mode as well as in pathological modes. Usage of certain values for feedback and delay parameters allows simulating the heart action when an accessory conducting pathway is present (Wolff-Parkinson-White syndrome.

  10. Eccentric apical hypertrophic cardiomyopathy unmasked by multimodality imaging: an uncommon but missed cause of out of hospital cardiac arrest

    Science.gov (United States)

    Towe, Eric; Sharma, Saurabh; Geske, Jeffrey; Ackerman, Michael J

    2015-01-01

    A woman in her late 50s experienced a witnessed, sudden out of hospital cardiac arrest. Initial workup included coronary angiography, transthoracic echocardiogram and a CT scan of the chest to rule out pulmonary embolus. She was subsequently discharged home without an implantable cardioverter defibrillator (ICD) or a life vest. On follow-up at another facility, an ICD was placed and a Holter monitor showed no ventricular ectopy. Further transthoracic echocardiographic images were obtained, which were suggestive of apical hypertrophic cardiomyopathy. A limited transthoracic echocardiogram with contrast was performed, which did not elucidate the hypertrophy. However, eccentric left ventricular apical wall hypertrophy was visualised by a coronary CT scan. PMID:26153133

  11. Evaluación de arritmias con base en el método de ayuda diagnóstica de la dinámica cardiaca basado en la teoría de la probabilidad

    OpenAIRE

    prirto bohorquez, Signed; bautista, Jairo; correa herra, Catalina; lópez garcía, Fredy; valero, Laura; velasco, Alejandro; méndez pino, Laura; bernal, Hebert; hoyos, Natalia

    2015-01-01

     Objetivo: confirmar la capacidad diagnóstica de la metodología en casos de arritmia.Materiales y métodos: se realizó un estudio ciego, en el que se estudiaron 10  holter normales y 90 con diferentes tipos de arritmia, mayores de 21 años. Se enmascaró el diagnóstico convencional y se calculó la probabilidad de rangos de frecuencias cardiacas máximas, mínimas e intermedias cada hora, y  de número de latidos por hora, para determinar el diagnóstico matemático de acuerdo con los  tres parámetros...

  12. Uso da radiofrequência bipolar para o tratamento da fibrilação atrial durante cirurgia cardíaca Uso de la radiofrecuencia bipolar para el tratamiento de la fibrilación atrial durante cirugía cardíaca Use of bipolar radiofrequency for the treatment of atrial fibrillation during cardiac surgery

    Directory of Open Access Journals (Sweden)

    Leonardo Secchin Canale

    2011-06-01

    Full Text Available FUNDAMENTO: O tratamento da fibrilação atrial com dispositivo de ablação de tecidos por radiofrequência bipolar em concomitância à cirurgia cardíaca tem se mostrado método eficaz no tratamento desta arritmia. OBJETIVO: Descrever a experiência inicial do Instituto Nacional de Cardiologia no tratamento cirúrgico da fibrilação atrial com uso de dispositivo de radiofrequência bipolar em pacientes submetidos à cirurgia cardíaca, relatando o resultado de acompanhamento pós-operatório de um ano. MÉTODOS: Entre janeiro de 2008 e março de 2009, 47 pacientes (36 mulheres consecutivos, com idade média de 53,7 ± 10,6 anos, apresentando fibrilação atrial por um período médio de 34,6 meses (3 a 192 meses foram submetidos à ablação cirúrgica desta arritmia, por radiofrequência bipolar, durante o procedimento que motivou a indicação da cirurgia. Oito apresentavam fibrilação atrial intermitente e 39, contínua. Oitenta e um por cento foram submetidos à cirurgia valvar como procedimento principal. Esta é uma análise retrospectiva, observacional, com avaliação de um ano de pós-operatório das variáveis clínicas e de Holter 24 h. RESULTADOS: Dos 47 pacientes, 40 sobreviveram um ano. Desses, 33 foram submetidos a Holter 24 h, em um intervalo médio de 401 dias após a cirurgia. Encontrou-se a seguinte distribuição de ritmos: 24 (73% sinusal, 5 (15% fibrilação atrial, três (9% Flutter atrial e um (3% ritmo juncional. Foram observados dois acidentes vasculares encefálicos, sendo um associado à arritmia supraventricular. CONCLUSÃO: A ablação cirúrgica de fibrilação atrial com dispositivo de radiofrequência bipolar concomitante à cirurgia cardíaca é método eficaz para o tratamento desta arritmia.FUNDAMENTO: El tratamiento de la fibrilación atrial con dispositivo de ablación de tejidos por radiofrecuencia bipolar en concomitancia con la cirugía cardíaca se muestra un método eficaz en el tratamiento de esta

  13. Depressed heart rate variability as an independent predictor of death in chronic congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy.

    Science.gov (United States)

    Ponikowski, P; Anker, S D; Chua, T P; Szelemej, R; Piepoli, M; Adamopoulos, S; Webb-Peploe, K; Harrington, D; Banasiak, W; Wrabec, K; Coats, A J

    1997-06-15

    After acute myocardial infarction, depressed heart rate variability (HRV) has been proven to be a powerful independent predictor of a poor outcome. Although patients with chronic congestive heart failure (CHF) have also markedly impaired HRV, the prognostic value of HRV analysis in these patients remains unknown. The aim of this study was to investigate whether HRV parameters could predict survival in 102 consecutive patients with moderate to severe CHF (90 men, mean age 58 years, New York Heart Association [NYHA] class II to IV, CHF due to idiopathic dilated cardiomyopathy in 24 patients and ischemic heart disease in 78 patients, ejection fraction [EF], 26%; peak oxygen consumption, 16.9 ml/kg/min) after exclusion of patients in atrial fibrilation with diabetes or with chronic renal failure. In the prognostic analysis (Cox proportional-hazards model, Kaplan-Meier survival analysis), the following factors were investigated: age, CHF etiology, NYHA class, EF, peak oxygen consumption, presence of ventricular tachycardia on Holter monitoring, and HRV measures derived from 24-hour electrocardiography monitoring, calculated in the time (standard deviation of all normal RR intervals [SDNN], standard deviation of 5-minute RR intervals [SDANN], mean of all 5-minute standard deviations of RR intervals [SD], root-mean-square of difference of successive RR intervals [rMSSD], and percentage of adjacent RR intervals >50 ms different [pNN50]) and frequency domain (total power [TP], power within low-frequency band [LF], and power within high-frequency band [HF]). During follow-up of 584 +/- 405 days (365 days in all who survived), 19 patients (19%) died (mean time to death: 307 +/- 315 days, range 3 to 989). Cox's univariate analysis identified the following factors to be predictors of death: NYHA (p = 0.003), peak oxygen consumption (p = 0.01), EF (p = 0.02), ventricular tachycardia on Holter monitoring (p = 0.05), and among HRV measures: SDNN (p = 0.004), SDANN (p = 0.003), SD

  14. The effects of home oxygen therapy on energy metabolism in patients with COPD

    Science.gov (United States)

    Kırıcı Berber, Nurcan; Yetkin, Özkan; Kılıç, Talat; Berber, Ilhami; Özgel, Mehmet

    2018-01-01

    Background COPD is preventable and treatable and is characterized by completely nonreversible airflow obstruction. In this study, we aimed to investigate the effect of long-term oxygen therapy on patients with stage 4 COPD who were followed up and treated at the polyclinic or clinic service. We evaluated the effects of oxygen therapy on energy metabolism and physical activity in patients with COPD. Methods Nineteen patients with COPD (16 male/3 female), treated with oxygen therapy for the first time, were included in this study. Analysis of arterial blood gases and pulmonary function test was performed. Metabolic Holter device (SenseWear® Armband) was placed pre- and post-oxygen therapy on the patients’ arm for at least 3 days. This device captures Holter data in a digitized electronic system, and the daily average value was calculated from the data. Results Post-oxygen treatment showed a significant increase in energy expenditure by patients with COPD (pretreatment, 1,497±596 joule; posttreatment, 2,977±5,985 joule; P=0.044). Moreover, number of steps during walking (pretreatment, 2,056±256; posttreatment, 2,120±195; P=0.03), resting (pretreatment, 6.36±3.31 hours; posttreatment, 3.47±2.19 hours; P<0.03), and sleeping (pretreatment, 4.23±2.13 hours; posttreatment, 2.33±1.42 hours; P<0.00) showed significant differences. Increased daily energy expenditure in patients with respiratory failure was detected with long-term oxygen therapy. In addition, the immobility of patients decreased and duration of physical activity increased in patients with COPD. Conclusion In this study, positive effects of long-term oxygen therapy have been demonstrated with respect to energy metabolism and physical activity of patients with COPD. Thus, we recommend that medication adherence and long-term oxygen therapy should begin early in patients with COPD.

  15. The impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot.

    Science.gov (United States)

    Ávila, Pablo; Marcotte, François; Dore, Annie; Mercier, Lise-Andrée; Shohoudi, Azadeh; Mongeon, François-Pierre; Mondésert, Blandine; Proietti, Anna; Ibrahim, Reda; Asgar, Anita; Poirier, Nancy; Khairy, Paul

    2016-09-15

    Sudden death of presumed arrhythmic etiology is the leading cause of mortality in adults with tetralogy of Fallot. To assess the impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot. Adults with repaired tetralogy of Fallot were randomized in a 2:1 ratio to an open-label trial of standard care versus 12weeks of supervised combined aerobic/resistance training with continuous Holter monitoring. Proportion of premature ventricular complexes (PVC) and runs of non-sustained ventricular tachycardia (NSVT) were assessed by mixed and Poisson regression models with generalized estimating equations for repeated measures. A total of 152 Holters were performed in 17 patients, median age 35 (interquartile range [IQR] 28, 42) years, 65% male, 13 of whom were randomized to exercise training. Baseline characteristics were similar between groups. Exercise training resulted in significant increases in peak oxygen uptake (11±19%, p=0.028), metabolic equivalents (11±18%, p=0.027), and exercise duration (8±10%, p=0.009) compared to no changes in controls. Frequent (≥30 per hour) PVCs were present in 46% of patients, couplets in 62%, and 3 to 7 beat runs of NSVT in 31%. The median proportion of PVCs was 1.93‰ (IQR 0.41, 5.89) at baseline and 1.45‰ (IQR 0.08, 2.76) during the initial exercise session (p=0.722), and remained stable over time (ß coefficient=-0.031, p=0.408). Runs of NSVT decreased significantly over time (ß coefficient=-0.032, p=0.018). In adults with repaired tetralogy of Fallot, exercise training is safe, improves exercise capacity, and appears to confer a beneficial effect on ventricular arrhythmias. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Associação entre dissinergia miocárdica e arritmia ventricular na forma indeterminada da doença de Chagas

    Directory of Open Access Journals (Sweden)

    Márcio Lins Barros

    2011-04-01

    Full Text Available INTRODUÇÃO: Pacientes na forma indeterminada da doença de Chagas (FIDC podem apresentar anormalidades contráteis segmentares, com evidências de pior prognóstico comparativamente a pacientes com estudo ecocardiográfico normal. O objetivo deste estudo foi de avaliar a associação entre a presença de anormalidade contrátil segmentar e a presença de distúrbios do ritmo cardíaco na FIDC. MÉTODOS: Foram estudados 38 pacientes na FIDC, sendo 26 pacientes sem anormalidade contrátil e 12 com presença de distúrbio contrátil ao estudo ecocardiográfico. Todos os pacientes foram submetidos a um estudo ecocardiográfico completo, incluindo o Doppler tecidual, bem como à monitorização eletrocardiográfica de 24h (Holter. RESULTADOS: Entre as diversas variáveis estudadas, foram encontradas diferenças significativas entre os dois grupos em relação à fração de ejeção (p < 0,001, dimensão sistólica do ventrículo esquerdo (p = 0,029 e tempo de contração isovolumétrica (p < 0,05 medidos pela ecocardiografia e Doppler tecidual, bem como extrassistolia ventricular isolada (p = 0,016 e em pares (p = 0,003 pela avaliação pelo Holter. CONCLUSÕES: Pacientes na FIDC que apresentam anormalidades contráteis quando avaliados pela ecocardiografia apresentam episódios mais frequentes de extrassistolia ventricular, traduzindo um maior dano morfofuncional e elétrico do coração, quando comparados a pacientes que apresentem estudo ecocardiográfico normal.

  17. Does the STAF score help detect paroxysmal atrial fibrillation in acute stroke patients?

    Science.gov (United States)

    Horstmann, S; Rizos, T; Güntner, J; Hug, A; Jenetzky, E; Krumsdorf, U; Veltkamp, R

    2013-01-01

    Detecting paroxysmal atrial fibrillation (pAF) soon after acute cerebral ischaemia has a major impact on secondary stroke prevention. Recently, the STAF score, a composite of clinical and instrumental findings, was introduced to identify stroke patients at risk of pAF. We aimed to validate this score in an independent study population. Consecutive patients admitted to our stroke unit with acute ischaemic stroke were prospectively enrolled. The diagnostic work-up included neuroimaging, neuroultrasound, baseline 12-channel electrocardiogram (ECG), 24-h Holter ECG, continuous ECG monitoring, and echocardiography. Presence of AF was documented according to the medical history of each patient and after review of 12-lead ECG, 24-h Holter ECG, or continuous ECG monitoring performed during the stay on the ward. Additionally, a telephone follow-up visit was conducted for each patient after 3 months to inquire about newly diagnosed AF. Items for each patient-age, baseline NIHSS, left atrial dilatation, and stroke etiology according to the TOAST criteria - were assessed to calculate the STAF score. Overall, 584 patients were enrolled in our analysis. AF was documented in 183 (31.3%) patients. In multivariable analysis, age, NIHSS, left atrial dilatation, and absence of vascular etiology were independent predictors for AF. The logistic AF-prediction model of the STAF score revealed fair classification accuracy in receiver operating characteristic curve analysis with an area under the curve of 0.84. STAF scores of ≥5 had a sensitivity of 79% and a specificity of 74% for predicting AF. The value of the STAF score for predicting the risk of pAF in stroke patients is limited. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  18. Relationship between the mismatch of 123I-BMIPP and 201Tl myocardial single-photon emission computed tomography and autonomic nervous system activity in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Yamanaka, Hiroyuki; Suzuki, Takeshi; Kishida, Hiroshi; Nagasawa, Koichi; Takano, Teruo

    2006-01-01

    The purpose of this study was to elucidate the relationship between the mismatch of thallium-201 (Tl) and iodine-123-beta-methyl-iodophenyl-pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography (SPECT) and autonomic nervous system activity in myocardial infarction (MI) patients. The subjects were 40 patients (34 males, 6 females) who underwent examinations by 123 I-BMIPP and 201 Tl myocardial SPECT imaging and 24-hour Holter monitoring within a 3-day period 3 weeks after the onset of their first MI. R-R intervals were analyzed every hour over a period of 24 hours by fast Fourier transformation (FFT). High frequency (HF) and low frequency (LF) were defined as markers of cardiac vagal activity in the former and the LF/HF ratio as sympathetic activity. Greater or more extensive decreases in the BMIPP image than that in the Tl image were defined as a positive mismatch. Patients were divided into positive and negative mismatch groups of 20 patients each. There were no significant differences between the 2 groups in age, sex, site of infarction, max CK (creatine kinase), max CK-MB, or left ventricular ejection fraction. The incidences of clinical signs suggesting residual myocardial ischemia were significantly greater in the positive than in the negative mismatch group (P 123 I-BMIPP and 201 Tl myocardial SPECT 3 weeks after a first acute myocardial infarction with uncomplicated moderate or severe heart failure and decreased heart rate variability are related to residual myocardial ischemia. A combined assessment of heart rate variability in 24 hour Holter electrocardiogram (ECG) monitoring and perfusion-metabolism mismatch in 123 I-BMIPP and 201 Tl myocardial SPECT is useful for determining residual myocardial ischemia in the follow-up of those with acute myocardial infarction. (author)

  19. Atrial ectopy predicts late recurrence of atrial fibrillation after pulmonary vein isolation.

    Science.gov (United States)

    Gang, Uffe J O; Nalliah, Chrishan J; Lim, Toon Wei; Thiagalingam, Aravinda; Kovoor, Pramesh; Ross, David L; Thomas, Stuart P

    2015-06-01

    Late recurrence of atrial fibrillation (AF) after radiofrequency ablation remains significant. Asymptomatic recurrence poses a difficult clinical problem as it is associated with an equally increased risk of stroke and death compared with symptomatic AF events. Meta-analyses reveal that no single preablation patient characteristic efficiently predicts these AF recurrences. This study aimed to evaluate the prognostic value of premature atrial complex (PAC) occurrence with regard to the risk of late AF recurrence after radiofrequency ablation. The study cohort consisted of 124 patients with 7-day Holter recordings at 6 months post radiofrequency ablation for AF. No patients had AF recurrence before this time. Patients were followed-up every 6 months. Holter-detected PACs were defined as any supraventricular complexes occurring >30% earlier than expected. During a median follow-up of 4.2 years (first quartile to third quartile [Q1-Q3]=1.6-4.5), 32 patients (26%) had late recurrences of AF at a median of 462 days (Q1-Q3=319-1026) post radiofrequency ablation. The number of PACs per 24 hours was 248 (Q1-Q3=62-1026) in patients with and 77 (Q1-Q3=24-448) in patients without recurrence of AF (P=0.02). Multivariate analysis of the risk of late AF recurrence found ≥142 PACs per 24 hours to have a hazard ratio 2.84 (confidence interval, 1.26-6.43), P=0.01. This study showed that occurrence of ≥142 PACs per day at 6 months after PVI was independently associated with a significantly increased risk of late AF recurrence. These results could have important clinical implications for the design of post-PVI follow-up. URL: http://www.anzctr.org.au. Unique identifier: ACRTN12606000467538. © 2015 American Heart Association, Inc.

  20. Early diagnosis of interferon-induced myocardial disorder in patients with chronic hepatitis C. Evaluation by myocardial imaging with {sup 123}I-BMIPP

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Yuki; Yukinaka, Michiko; Nomura, Masahiro; Nakaya, Yutaka; Ito, Susumu [Tokushima Univ. (Japan). School of Medicine

    2000-02-01

    Interferon (IFN) therapy for chronic hepatitis C is sometimes associated with cardiac complications. In the present study, we performed myocardial imaging with {sup 123}I-labeled {beta}-methyl-p-iodophenylpentadecanoic acid ({sup 123}I-BMIPP) in order to evaluate myocardial disorders caused by IFN. We studied 40 healthy subjects (H group) and 25 patients with chronic hepatitis C who had been treated with IFN (IFN group). A Holter electrocardiogram (ECG) was performed and the autonomic nervous function was assessed by analyzing the spectral variability and 1/f fluctuation of heart rate. Myocardial planner imaging with {sup 123}I-BMIPP was performed to obtain the time activity curve for 20 min immediately after administration of {sup 123}I-BMIPP (dynamic study). Early and delayed myocardial single photon emission computed tomography (SPECT) images were expressed as Bull's eyes and the myocardium was divided into four segments to calculate the washout rate for each segment on early and late SPECT images (early and late SPECT study). No significant differences in autonomic nervous function were observed between the two groups in heart rate variability. In a dynamic study, the reduction rate from the time activity curve was significantly higher in the IFN group compared with the H group (reduction rate, IFN group, 5.3{+-}3.7% vs H group, 1.2{+-}3.3%; P<0.05). In the early and delayed myocardial SPECT study, the washout rate for the IFN group was significantly increased in all myocardial areas compared to that in the H group. However, the metabolic disorder of fatty acids caused by IFN was reversed on the second {sup 123}I-BMIPP myocardial scintigraphy examination several months after IFN therapy. These results indicate that metabolic disorders of fatty acids caused by IFN therapy can be detected before abnormalities are observed by Holter-ECG or echocardiography. (author)

  1. A double-blind, placebo-controlled, randomised, parallel-group, dose-escalating, repeat dose study in healthy volunteers to evaluate the safety, tolerability, pharmacodynamic effects and pharmacokinetics of the once daily rectal application of NRL001 suppositories for 14 days.

    Science.gov (United States)

    Bell, D; Duffin, A; Jacobs, A; Pediconi, C; Gruss, H J

    2014-03-01

    The 1R,2S stereoisomer of methoxamine hydrochloride, NRL001, is a highly selective α1-adrenoceptor agonist being developed for the local treatment of non-structural faecal incontinence caused by weak internal anal sphincter tone. This study investigated the steady state pharmacokinetics (PK) and safety of 2 g rectal suppositories containing NRL001 in different strengths (7.5, 10, 12.5 or 15 mg). Healthy volunteers aged 18-45 years received 14 daily doses of NRL001 2 g suppositories or matching placebo. In each dose group nine participants received NRL001 and three received placebo. Blood samples to determine NRL001 concentrations were taken on Days 1, 7 and 14. Cardiovascular parameters were collected via electrocardiograms, Holter monitoring (three lead Holter monitor) and vital signs. Forty-eight volunteers were enrolled; 43 completed the study and were included in the PK analysis population. AUC and Cmax broadly increased with increasing dose, Tmax generally occurred between 4.0 and 5.0 h. Although the data did not appear strongly dose proportional, dose proportionality analysis did not provide evidence against dose proportionality as the log(dose) coefficients were not significantly < 1. NRL001 did not accumulate over time for any dose. Increasing NRL001 concentrations were related to changes in vital sign variables, most notably decreased heart rate. The most commonly reported adverse events (AEs) in the active treatment groups were paraesthesia and piloerection. Treatment with NRL001 was generally well tolerated over 14 days once daily dosing and plasma NRL001 did not accumulate over time. Treatment was associated with changes in vital sign variables, most notably decreased heart rate. AEs commonly reported with NRL001 treatment were events indicative of a systemic α-adrenergic effect. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  2. Predictors of Sudden Cardiac Death in Doberman Pinschers with Dilated Cardiomyopathy.

    Science.gov (United States)

    Klüser, L; Holler, P J; Simak, J; Tater, G; Smets, P; Rügamer, D; Küchenhoff, H; Wess, G

    2016-05-01

    Doberman Pinschers with dilated cardiomyopathy (DCM) are at high risk of sudden cardiac death (SCD). Risk factors for SCD are poorly defined. To assess cardiac biomarkers, Holter-ECG, echocardiographic variables and canine characteristics in a group of Doberman Pinschers with DCM dying of SCD and in a DCM control group to identify factors predicting SCD. A longitudinal prospective study was performed in 95 Doberman Pinschers with DCM. Forty-one dogs died within 3 months after the last cardiac examination (SCD-group) and were compared to 54 Doberman Pinschers with DCM surviving 1 year after inclusion. Holter-ECG, echocardiography, measurement of N-terminal prohormone of brain-natriuretic peptide (NT-proBNP), and cardiac Troponin I (cTnI) concentrations were recorded for all dogs. Volume overload of the left ventricle (left ventricular end-diastolic volume (LVEDV/BSA) > 91.3 mL/m²) was the single best variable to predict SCD. The probability of SCD increases 8.5-fold (CI0.95  = 0.8-35.3) for every 50 mL/m²-unit increment in LVEDV/BSA. Ejection fraction (EF), left ventricular end-systolic volume (LVESV/BSA) and NT-proBNP were highly correlated with LVEDV/BSA (r = -0.63, 0.96, 0.86, respectively). Generated conditional inference trees (CTREEs) revealed that the presence of ventricular tachycardia (VT), increased concentration of cTnI, and the fastest rate (FR) of ventricular premature complexes (VPC) ≥260 beats per minute (bpm) are additional important variables to predict SCD. Conditional inference trees provided in this study might be useful for risk assessment of SCD in Doberman Pinschers with DCM. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  3. β1-Adrenoceptor blocker aggravated ventricular arrhythmia.

    Science.gov (United States)

    Wang, Yan; Patel, Dimpi; Wang, Dao Wu; Yan, Jiang Tao; Hsia, Henry H; Liu, Hao; Zhao, Chun Xia; Zuo, Hou Juan; Wang, Dao Wen

    2013-11-01

    To assess the impact of β1 -adrenoceptor blockers (β1 -blocker) and isoprenaline on the incidence of idiopathic repetitive ventricular arrhythmia that apparently decreases with preprocedural anxiety. From January 2010 to July 2012, six patients were identified who had idiopathic ventricular arrhythmias that apparently decreased (by greater than 90%) with preprocedural anxiety. The number of ectopic ventricular beats per hour (VPH) was calculated from Holter or telemetry monitoring to assess the ectopic burden. The mean VPH of 24 hours from Holter before admission (VPH-m) was used as baseline (100%) for normalization. β1 -Blockers, isoprenaline, and/or aminophylline were administrated successively on the ward and catheter lab to evaluate their effects on the ventricular arrhythmias. Among 97 consecutive patients with idiopathic ventricular arrhythmias, six had reduction in normalized VPHs in the hour before the scheduled procedure time from (104.6 ± 4.6%) to (2.8 ± 1.6%) possibly due to preprocedural anxiety (P < 0.05), then increased to (97.9 ± 9.7%) during β1 -blocker administration (P < 0.05), then quickly reduced to (1.6 ± 1.0%) during subsequent isoprenaline infusion. Repeated β1 -blocker quickly counteracted the inhibitory effect of isoprenaline, and VPHs increased to (120.9 ± 2.4%) from (1.6 ± 1.0%; P < 0.05). Isoprenaline and β1 -blocker showed similar effects on the arrhythmias in catheter lab. In some patients with structurally normal heart and ventricular arrhythmias there is a marked reduction of arrhythmias associated with preprocedural anxiety. These patients exhibit a reproducible sequence of β1 -blocker aggravation and catecholamine inhibition of ventricular arrhythmias, including both repetitive ventricular premature beats and monomorphic ventricular tachycardia. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  4. Gender differences of heart rate variability in healthy volunteers

    International Nuclear Information System (INIS)

    Saleem, S.; Majeed, S.M.I.; Khan, M.A.

    2012-01-01

    Objective: To identify the basic values of heart rate variability in Pakistani population and to verify our hypothesis that there are gender differences in cardiovascular autonomic modulation. Methods: The descriptive cross sectional study based on convenience probability sampling was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD) Pakistan. The duration of the study was from December 2009 to July 2010. It involved 24-hour holter monitoring of 45 healthy individuals using holter electrocardiography (ECG) recorder. Heart rate variability was analysed in time (SDNN, SDANN, SDNNi, rMSSD, pNN50) and frequency domains (power, VLF, LF, and HF). Results: The time domain indices; SDNN (male=140 +- 36 ms vs. females=122 +- 33 ms; p =0.09), SDANN (male=123 +- 34 ms vs. females=111+- 34 ms; P= 0.23), SDNNi (male=64 +-19 ms vs. females=52 +- 14 ms; P= 0.03), and pNN50 (male=14 +- 10 ms vs. females=12 +- 7 ms; P= 0.43) were decreased in female volunteers when compared with males. Comparison of frequency domain indices; Total power (male=4041 +- 3150 ms/sup 2/ vs. females=2750 +- 1439 ms/sup 2/; P= 0.07), VLF (male=291 2675 ms/sup 2/ vs. females=1843 +- 928 ms/sup 2/; P= 0.06), LF (male=788 +- 397 ms/sup 2/ vs. females=556 +- 346 ms/sup 2/; P= 0.04) and HF (male=318 +- 251 ms/sup 2/ vs. females=31 277 ms/sup 2/; P= 0.94) amongst males and females showed attenuated heart rate variability in females. Of all the observed values, SDNNi and LF were found significantly (p <0.05) decreased in women. Conclusion: In healthy population, heart rate variability is low in women than men. It reflects sympathetic dominance in women in our population. (author)

  5. Blunted cyclic variation of heart rate predicts mortality risk in post-myocardial infarction, end-stage renal disease, and chronic heart failure patients.

    Science.gov (United States)

    Hayano, Junichiro; Yasuma, Fumihiko; Watanabe, Eiichi; Carney, Robert M; Stein, Phyllis K; Blumenthal, James A; Arsenos, Petros; Gatzoulis, Konstantinos A; Takahashi, Hiroshi; Ishii, Hideki; Kiyono, Ken; Yamamoto, Yoshiharu; Yoshida, Yutaka; Yuda, Emi; Kodama, Itsuo

    2017-08-01

    Cyclic variation of heart rate (CVHR) associated with sleep-disordered breathing is thought to reflect cardiac autonomic responses to apnoeic/hypoxic stress. We examined whether blunted CVHR observed in ambulatory ECG could predict the mortality risk. CVHR in night-time Holter ECG was detected by an automated algorithm, and the prognostic relationships of the frequency (FCV) and amplitude (ACV) of CVHR were examined in 717 patients after myocardial infarction (post-MI 1, 6% mortality, median follow-up 25 months). The predictive power was prospectively validated in three independent cohorts: a second group of 220 post-MI patients (post-MI 2, 25.5% mortality, follow-up 45 months); 299 patients with end-stage renal disease on chronic haemodialysis (ESRD, 28.1% mortality, follow-up 85 months); and 100 patients with chronic heart failure (CHF, 35% mortality, follow-up 38 months). Although CVHR was observed in ≥96% of the patients in all cohorts, FCV did not predict mortality in any cohort. In contrast, decreased ACV was a powerful predictor of mortality in the post-MI 1 cohort (hazard ratio [95% CI] per 1 ln [ms] decrement, 2.9 [2.2-3.7], P < 0.001). This prognostic relationship was validated in the post-MI 2 (1.8 [1.4-2.2], P < 0.001), ESRD (1.5 [1.3-1.8], P < 0.001), and CHF (1.4 [1.1-1.8], P = 0.02) cohorts. The prognostic value of ACV was independent of age, gender, diabetes, β-blocker therapy, left ventricular ejection fraction, sleep-time mean R-R interval, and FCV. Blunted CVHR detected by decreased ACV in a night-time Holter ECG predicts increased mortality risk in post-MI, ESRD, and CHF patients. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology.

  6. Science.gov (United States)

    Prieto Bohórquez, Signed Esperanza; Rodríguez Velásquez, Javier Oswaldo; Correa Herrera, Catalina; Pardo Oviedo, Juan Mauricio; Ardila, Javier

    2018-03-23

    Introducción: una ley exponencial se ha hallado para los sistemas dinámicos caóticos cardiacos, logrando cuantificar las diferencias entre dinámicas cardiacas normales y  patológicas.Metodología: Se analizaron 120 registros electrocardiográficos, 40 correspondían a sujetos dentro de los límites de normalidad y 80 con diferentes patologías. Para cada holter se analizaron los atractores generados con los datos durante 18 horas y durante toda la dinámica. Se calculó la dimensión fractal del atractor y su ocupación espacial. A estas medidas se aplicó la evaluación matemática diagnostica desarrollada previamente, comparando la evaluación para 18 horas y para todo el registro; finalmente se calculó la sensibilidad, especificidad y coeficiente Kappa.Resultados: Para las dinámicas normales los espacios de ocupación en la rejilla Kp estuvieron entre 200 y 381 en la evaluación de la totalidad del holter, y entre 201 y 384 en la evaluación durante 18 horas, mostrando la cercanía en las medidas, lo que permite que la disminución en el tiempo de la evaluación sea consistente, esta misma cercanía se observó para las dinámicas enfermas y agudas.Conclusión: Se evidenció la aplicabilidad clínica en 18 horas de la ley exponencial en la dinámica cardiaca caótica asociada a arritmias mostrando ser de utilidad para la predicción de la evolución hacia estados agudos de la dinámica.

  7. Blunted cyclic variation of heart rate predicts mortality risk in post-myocardial infarction, end-stage renal disease, and chronic heart failure patients

    Science.gov (United States)

    Hayano, Junichiro; Yasuma, Fumihiko; Watanabe, Eiichi; Carney, Robert M.; Stein, Phyllis K.; Blumenthal, James A.; Arsenos, Petros; Gatzoulis, Konstantinos A.; Takahashi, Hiroshi; Ishii, Hideki; Kiyono, Ken; Yamamoto, Yoshiharu; Yoshida, Yutaka; Yuda, Emi; Kodama, Itsuo

    2017-01-01

    Abstract Aims Cyclic variation of heart rate (CVHR) associated with sleep-disordered breathing is thought to reflect cardiac autonomic responses to apnoeic/hypoxic stress. We examined whether blunted CVHR observed in ambulatory ECG could predict the mortality risk. Methods and results CVHR in night-time Holter ECG was detected by an automated algorithm, and the prognostic relationships of the frequency (FCV) and amplitude (ACV) of CVHR were examined in 717 patients after myocardial infarction (post-MI 1, 6% mortality, median follow-up 25 months). The predictive power was prospectively validated in three independent cohorts: a second group of 220 post-MI patients (post-MI 2, 25.5% mortality, follow-up 45 months); 299 patients with end-stage renal disease on chronic haemodialysis (ESRD, 28.1% mortality, follow-up 85 months); and 100 patients with chronic heart failure (CHF, 35% mortality, follow-up 38 months). Although CVHR was observed in ≥96% of the patients in all cohorts, FCV did not predict mortality in any cohort. In contrast, decreased ACV was a powerful predictor of mortality in the post-MI 1 cohort (hazard ratio [95% CI] per 1 ln [ms] decrement, 2.9 [2.2–3.7], P < 0.001). This prognostic relationship was validated in the post-MI 2 (1.8 [1.4–2.2], P < 0.001), ESRD (1.5 [1.3–1.8], P < 0.001), and CHF (1.4 [1.1–1.8], P = 0.02) cohorts. The prognostic value of ACV was independent of age, gender, diabetes, β-blocker therapy, left ventricular ejection fraction, sleep-time mean R-R interval, and FCV. Conclusion Blunted CVHR detected by decreased ACV in a night-time Holter ECG predicts increased mortality risk in post-MI, ESRD, and CHF patients. PMID:27789562

  8. Atriofascicular Mahaim with Ebstein anomaly: A case report

    Directory of Open Access Journals (Sweden)

    Kazushi Ueshima, MD

    2017-10-01

    Full Text Available We report a case of a 7-year-old girl with atriofascicular Mahaim (AFM pathway concomitant with Ebstein's anomaly. The QRS wave showed left bundle branch block pattern on electrocardiogram. Holter electrocardiogram showed prolongation of the PR interval and QRS morphological change during sinus tachycardia. An electrophysiological study demonstrated that the distal His potential appeared earlier than the proximal His potential, which suggested retrograde His conduction toward the atrioventricular node. Conduction from the Mahaim fiber to the His bundle was faster than that from the atrioventricular node towards the His bundle. The findings of this important case allowed a differential diagnosis between AFM and Wolff-Parkinson-White (WPW syndrome.

  9. Evaluation of Commercial Self-Monitoring Devices for Clinical Purposes

    DEFF Research Database (Denmark)

    Leth, Soren; Hansen, John; Nielsen, Olav W

    2017-01-01

    Commercial self-monitoring devices are becoming increasingly popular, and over the last decade, the use of self-monitoring technology has spread widely in both consumer and medical markets. The purpose of this study was to evaluate five commercially available self-monitoring devices for further...... activity trackers and compared to gyroscope readings. Two trackers were also tested on nine subjects by comparing pulse readings to Holter monitoring. RESULTS: The lowest average systematic error in the walking tests was -0.2%, recorded on the Garmin Vivofit 2 at 3.5 km/h; the highest error was the Fitbit...... the current functionality and limitations of the five self-tracking devices, and point towards a need for future research in this area....

  10. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  11. Arrhythmogenic effects of hypoglycemia in children and adolescents with type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Dmitriy Nikitich Laptev

    2013-12-01

    Full Text Available Aim. To determine the effects of hypoglycemia on the duration of QT interval, heart rate variability (HRV and frequency of arrhythmic events, as well as to closer investigate the factors associated with the development of various heart rhythm disorders in children and adolescents with type 1 diabetes mellitus (T1DM. Materials and methods.  The study included 150 children and adolescents with T1DM at the age of 6?18 years. All participants underwent Holter monitoring and continuous glucose monitoring (CGM for 24 hours. QTc and HRV parameters (SDNN, RMSSD, SVVR were calculated automatically. Data was averaged for 5?-interval and juxtaposed with CGM. Patients identified with hypoglycemic events (blood glucose

  12. AN ADVANCED OXIDATION PROCESS : FENTON PROCESS

    Directory of Open Access Journals (Sweden)

    Engin GÜRTEKİN

    2008-03-01

    Full Text Available Biological wastewater treatment is not effective treatment method if raw wastewater contains toxic and refractory organics. Advanced oxidation processes are applied before or after biological treatment for the detoxification and reclamation of this kind of wastewaters. The advanced oxidation processes are based on the formation of powerful hydroxyl radicals. Among advanced oxidation processes Fenton process is one of the most promising methods. Because application of Fenton process is simple and cost effective and also reaction occurs in a short time period. Fenton process is applied for many different proposes. In this study, Fenton process was evaluated as an advanced oxidation process in wastewater treatment.

  13. Control system for technological processes in tritium processing plants with process analysis

    International Nuclear Information System (INIS)

    Retevoi, Carmen Maria; Stefan, Iuliana; Balteanu, Ovidiu; Stefan, Liviu; Bucur, Ciprian

    2005-01-01

    Integration of a large variety of installations and equipment into a unitary system for controlling the technological process in tritium processing nuclear facilities appears to be a rather complex approach particularly when experimental or new technologies are developed. Ensuring a high degree of versatility allowing easy modifications in configurations and process parameters is a major requirement imposed on experimental installations. The large amount of data which must be processed, stored and easily accessed for subsequent analyses imposes development of a large information network based on a highly integrated system containing the acquisition, control and technological process analysis data as well as data base system. On such a basis integrated systems of computation and control able to conduct the technological process could be developed as well protection systems for cases of failures or break down. The integrated system responds to the control and security requirements in case of emergency and of the technological processes specific to the industry that processes radioactive or toxic substances with severe consequences in case of technological failure as in the case of tritium processing nuclear plant. In order to lower the risk technological failure of these processes an integrated software, data base and process analysis system are developed, which, based on identification algorithm of the important parameters for protection and security systems, will display the process evolution trend. The system was checked on a existing plant that includes a removal tritium unit, finally used in a nuclear power plant, by simulating the failure events as well as the process. The system will also include a complete data base monitoring all the parameters and a process analysis software for the main modules of the tritium processing plant, namely, isotope separation, catalytic purification and cryogenic distillation

  14. The impact of major depression on heart rate variability and endothelial dysfunction in patients with stable coronary artery disease.

    Science.gov (United States)

    Aydin Sunbul, Esra; Sunbul, Murat; Gulec, Huseyin

    Depression is an independent risk factor in cardiovascular diseases. Changes in the cardiac autonomic functions and pro-inflammatory processes are potential biological factors. Endothelial dysfunction plays an important role in the etiopathogenesis of atherosclerosis. Our objective was to evaluate the impact of major depression on heart rate variability and endothelial dysfunction in patients with stable CAD. The study group included 65 CAD patients with a diagnosis of major depression and 54 CAD patients without major depression. All study population underwent transthoracic echocardiography, measurement of flow mediated dilatation (FMD) and 24-h holter recording for heart rate variability (HRV). Blood samples were drawn to determine the inflammatory parameters. Severity of depressive episode was assessed by Montgomery-Asberg Depression Scale (MADRS). The distribution of age and sex was similar in the patient and control groups (P=0.715, 0.354, respectively). There was no significant difference in medications used between the groups. Echocardiographic parameters were similar between the groups. Inflammatory parameters were also similar between the groups. HRV parameters were significantly lower in the patient group than controls. The absolute FMD value and percentage FMD were significantly lower in the patient group than controls (Pgender (Pgender. Clinician should pay more attention for evaluation of depressive patients with CAD. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. A low-power bio-potential acquisition system with flexible PDMS dry electrodes for portable ubiquitous healthcare applications.

    Science.gov (United States)

    Chen, Chih-Yuan; Chang, Chia-Lin; Chang, Chih-Wei; Lai, Shin-Chi; Chien, Tsung-Fu; Huang, Hong-Yi; Chiou, Jin-Chern; Luo, Ching-Hsing

    2013-03-04

    This work describes a bio-potential acquisition system for portable ubiquitous healthcare applications using flexible polydimethylsiloxane dry electrodes (FPDEs) and a low-power recording circuit. This novel FPDE used Au as the skin contact layer, which was made using a CO2 laser and replica method technology. The FPDE was revised from a commercial bio-potential electrode with a conductive snap using dry electrodes rather than wet electrodes that proposed reliable and robust attachment for the purpose of measurement, and attaching velcro made it wearable on the forearm for bio-potential applications. Furthermore, this study proposes a recording device to store bio-potential signal data and provides portability and low-power consumption for the proposed acquisition system. To acquire differential bio-potentials, such as electrocardiogram (ECG) signals, the proposed recording device includes a low-power front-end acquisition chip fabricated using a complementary metal-oxide-semiconductor (CMOS) process, a commercial microcontroller (MSP430F149), and a secure digital (SD) card for portable healthcare applications. The proposed system can obtain ECG signals efficiently and are comfortable to the skin. The power consumption of the system is about 85 mW for continuous working over a 3 day period with two AA batteries. It can also be used as a compact Holter ECG system.

  16. STRUCTURAL AND FUNCTIONAL CHANGES EVALUATED BY ECHOCARDIOGRAPHY IN PATIENTS WITH SYSTEMIC SCLEROSIS AND HEART RATE VARIABILITY

    Directory of Open Access Journals (Sweden)

    E. O. Saad

    2017-01-01

    Full Text Available Objective: to estimate heart rate variability (HRV in patients with systemic sclerosis (SS and to investigate their relationship to echocardiographic structural and functional changes in the heart.Subjects and methods. The investigation enrolled 125 patients with SS and 50 gender- and age-matched apparently healthy individuals who made up a control group. In addition to clinical examinations, 73 patients underwent HRV assessment from 24-hour Holter electrocardiogram (ECG monitoring results and 121 patients had echocardiography (EchoCG. 24-hour Holter ECG monitoring was carried out in all control individuals.Results and discussion. Examination of the main parameters of time-domain HRV in patients with SS revealed a significant decline in all temporal and spectral indices, except for the mean R–R interval duration (meanNN, as compared with the control group. EchoCG detected a variety of changes, primarily the induration and calcification of aortic and mitral valves in most patients. Left ventricular diastolic dysfunction was encountered in almost half of the patients with SS. Eight patients had a lower left ventricular ejection fraction (LVEF, which was <55%. Studying the association of HRV values with separate EchoCG parameters revealed significant inverse correlations of the mean standard deviation of R–R intervals in 5-minute recording segments during 24 hours with the thickness of the interventricular septum (r = -0.18; p < 0.05 and with the induration of the aortic valve (r = -0.18; p < 0.05; the square root mean squared of successive differences (RMSSD, ms for R–R intervals and the percentage of adjacent R–R intervals that varied by more than 50 ms (pNN50 correlated with the induration of the aortic valve (r = -0.23; p<0.05 and r = -0.25; p < 0.05, respectively, with the presence of pericarditis (r = -0.24; p < 0.05 and r = -0,27; p < 0.05, respectively, and with the level of pulmonary artery systolic pressure (r = -0

  17. Markov Processes in Image Processing

    Science.gov (United States)

    Petrov, E. P.; Kharina, N. L.

    2018-05-01

    Digital images are used as an information carrier in different sciences and technologies. The aspiration to increase the number of bits in the image pixels for the purpose of obtaining more information is observed. In the paper, some methods of compression and contour detection on the basis of two-dimensional Markov chain are offered. Increasing the number of bits on the image pixels will allow one to allocate fine object details more precisely, but it significantly complicates image processing. The methods of image processing do not concede by the efficiency to well-known analogues, but surpass them in processing speed. An image is separated into binary images, and processing is carried out in parallel with each without an increase in speed, when increasing the number of bits on the image pixels. One more advantage of methods is the low consumption of energy resources. Only logical procedures are used and there are no computing operations. The methods can be useful in processing images of any class and assignment in processing systems with a limited time and energy resources.

  18. Effect of verapamil on heart rate variability after an acute myocardial infarction. Danish Verapamil Infarction Trial II

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner

    1998-01-01

    with verapamil significantly reduced sudden death, the aim of the present substudy was to evaluate the effect of verapamil on heart-rate variability in the time and frequency domain, measured in two 5-minute segments during the day and night. Thirty-eight patients were examined by Holter monitoring, at 1 week......-16 months of treatment. In accord with the known reduction of overall heart rate by verapamil, a significant increase of mean NN interval from before to after 1 (P = 0.0004) and 12-16 months (P = 0.004) of treatment was seen in the verapamil, but not in the placebo, group at night. Parameters generally......, the present study indicates that verapamil shifts the autonomic balance to a vagal preponderance or sympathetic attenuation in the postinfarction period....

  19. Monitoring and Detection Platform to Prevent Anomalous Situations in Home Care

    Directory of Open Access Journals (Sweden)

    Gabriel Villarrubia

    2014-06-01

    Full Text Available Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost.

  20. ECG scaling properties of cardiac arrhythmias using detrended fluctuation analysis

    International Nuclear Information System (INIS)

    Rodriguez, E; Echeverria, J C; Alvarez-Ramirez, J; Lerma, C

    2008-01-01

    We applied detrended fluctuation analysis to characterize at very short time scales during episodes of cardiac arrhythmias the raw electrocardiogram (ECG) waveform, aiming to get a global insight into its dynamical behaviour in patients who experienced sudden death. We found that in 15 recordings involving different types of arrhythmias (taken from PhysioNet's Sudden Cardiac Death Holter Database), the ECG waveform, besides showing a less-random dynamics, becomes more regular during bigeminy, ventricular tachycardia or even atrial fibrillation and ventricular fibrillation. The ECG waveform scaling properties thus suggest that reduced complexity dominates the underlying mechanisms of arrhythmias. Among other explanations, this may result from shorted or restricted (i.e. less diverse) pathways of conduction of the electrical activity within ventricles

  1. Relationship between vascular dysfunction in peripheral arteries and ischemic episodes during daily life in patients with ischemic heart disease and hypercholesterolemia

    DEFF Research Database (Denmark)

    Søndergaard, Eva; Møller, Jacob E; Egstrup, Kenneth

    2002-01-01

    cardiovascular risk factors. CONCLUSIONS: These results indicate a significant relationship between ischemic episodes and vascular dysfunction in patients with ischemic heart disease and hypercholesterolemia and may justify an aggressive preventive therapy targeted directly at the endothelium.......BACKGROUND: It is well established that endothelial dysfunction is present in patients with ischemic heart disease and hypercholesterolemia. Some of these patients will have signs of transient myocardial ischemia during Holter monitoring. We sought to describe the correlation between daily life...... ischemia and signs of endothelial dysfunction as assessed by means of brachial vasoreactivity. METHODS: We included in the study 131 patients with documented ischemic heart disease and a serum cholesterol level of > or =5 mmol/L before the institution of lipid-lowering treatment and dietary intervention...

  2. Thinning spatial point processes into Poisson processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Schoenberg, Frederic Paik

    , and where one simulates backwards and forwards in order to obtain the thinned process. In the case of a Cox process, a simple independent thinning technique is proposed. In both cases, the thinning results in a Poisson process if and only if the true Papangelou conditional intensity is used, and thus can......This paper describes methods for randomly thinning certain classes of spatial point processes. In the case of a Markov point process, the proposed method involves a dependent thinning of a spatial birth-and-death process, where clans of ancestors associated with the original points are identified...... be used as a diagnostic for assessing the goodness-of-fit of a spatial point process model. Several examples, including clustered and inhibitive point processes, are considered....

  3. Process validation for radiation processing

    International Nuclear Information System (INIS)

    Miller, A.

    1999-01-01

    Process validation concerns the establishment of the irradiation conditions that will lead to the desired changes of the irradiated product. Process validation therefore establishes the link between absorbed dose and the characteristics of the product, such as degree of crosslinking in a polyethylene tube, prolongation of shelf life of a food product, or degree of sterility of the medical device. Detailed international standards are written for the documentation of radiation sterilization, such as EN 552 and ISO 11137, and the steps of process validation that are described in these standards are discussed in this paper. They include material testing for the documentation of the correct functioning of the product, microbiological testing for selection of the minimum required dose and dose mapping for documentation of attainment of the required dose in all parts of the product. The process validation must be maintained by reviews and repeated measurements as necessary. This paper presents recommendations and guidance for the execution of these components of process validation. (author)

  4. Thinning spatial point processes into Poisson processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Schoenberg, Frederic Paik

    2010-01-01

    are identified, and where we simulate backwards and forwards in order to obtain the thinned process. In the case of a Cox process, a simple independent thinning technique is proposed. In both cases, the thinning results in a Poisson process if and only if the true Papangelou conditional intensity is used, and......In this paper we describe methods for randomly thinning certain classes of spatial point processes. In the case of a Markov point process, the proposed method involves a dependent thinning of a spatial birth-and-death process, where clans of ancestors associated with the original points......, thus, can be used as a graphical exploratory tool for inspecting the goodness-of-fit of a spatial point process model. Several examples, including clustered and inhibitive point processes, are considered....

  5. Late Results of Cox Maze III Procedure in Patients with Atrial Fibrillation Associated with Structural Heart Disease.

    Science.gov (United States)

    Gomes, Gustavo Gir; Gali, Wagner Luis; Sarabanda, Alvaro Valentim Lima; Cunha, Claudio Ribeiro da; Kessler, Iruena Moraes; Atik, Fernando Antibas

    2017-07-01

    Cox-Maze III procedure is one of the surgical techniques used in the surgical treatment of atrial fibrillation (AF). To determine late results of Cox-Maze III in terms of maintenance of sinus rhythm, and mortality and stroke rates. Between January 2006 and January 2013, 93 patients were submitted to the cut-and-sew Cox-Maze III procedure in combination with structural heart disease repair. Heart rhythm was determined by 24-hour Holter monitoring. Procedural success rates were determined by longitudinal methods and recurrence predictors by multivariate Cox regression models. Thirteen patients that obtained hospital discharge alive were excluded due to lost follow-up. The remaining 80 patients were aged 49.9 ± 12 years and 47 (58.7%) of them were female. Involvement of mitral valve and rheumatic heart disease were found in 67 (83.7%) and 63 (78.7%) patients, respectively. Seventy patients (87.5%) had persistent or long-standing persistent AF. Mean follow-up with Holter monitoring was 27.5 months. There were no hospital deaths. Sinus rhythm maintenance rates were 88%, 85.1% and 80.6% at 6 months, 24 months and 36 months, respectively. Predictors of late recurrence of AF were female gender (HR 3.52; 95% CI 1.21-10.25; p = 0.02), coronary artery disease (HR 4.73 95% CI 1.37-16.36; p = 0.01) and greater left atrium diameter (HR 1.05; 95% CI 1.01-1.09; p = 0.02). Actuarial survival was 98.5% at 12, 24 and 48 months and actuarial freedom from stroke was 100%, 100% and 97.5% in the same time frames. The Cox-Maze III procedure, in our experience, is efficacious for sinus rhythm maintenance, with very low late mortality and stroke rates. A operação de Cox-Maze III é uma das variantes técnicas no tratamento cirúrgico da fibrilação atrial (FA). Estudar os resultados tardios da operação de Cox-Maze III, quanto à eficácia na manutenção de ritmo sinusal e taxas de mortalidade e acidente vascular cerebral (AVC). Entre janeiro de 2006 a janeiro de 2013, 93 pacientes

  6. Process correlation analysis model for process improvement identification.

    Science.gov (United States)

    Choi, Su-jin; Kim, Dae-Kyoo; Park, Sooyong

    2014-01-01

    Software process improvement aims at improving the development process of software systems. It is initiated by process assessment identifying strengths and weaknesses and based on the findings, improvement plans are developed. In general, a process reference model (e.g., CMMI) is used throughout the process of software process improvement as the base. CMMI defines a set of process areas involved in software development and what to be carried out in process areas in terms of goals and practices. Process areas and their elements (goals and practices) are often correlated due to the iterative nature of software development process. However, in the current practice, correlations of process elements are often overlooked in the development of an improvement plan, which diminishes the efficiency of the plan. This is mainly attributed to significant efforts and the lack of required expertise. In this paper, we present a process correlation analysis model that helps identify correlations of process elements from the results of process assessment. This model is defined based on CMMI and empirical data of improvement practices. We evaluate the model using industrial data.

  7. Management of processes of electrochemical dimensional processing

    Science.gov (United States)

    Akhmetov, I. D.; Zakirova, A. R.; Sadykov, Z. B.

    2017-09-01

    In different industries a lot high-precision parts are produced from hard-processed scarce materials. Forming such details can only be acting during non-contact processing, or a minimum of effort, and doable by the use, for example, of electro-chemical processing. At the present stage of development of metal working processes are important management issues electrochemical machining and its automation. This article provides some indicators and factors of electrochemical machining process.

  8. Chemical process engineering in the transuranium processing plant

    International Nuclear Information System (INIS)

    Collins, E.D.; Bigelow, J.E.

    1976-01-01

    Since operation of the Transuranium Processing Plant began, process changes have been made to counteract problems caused by equipment corrosion, to satisfy new processing requirements, and to utilize improved processes. The new processes, equipment, and techniques have been incorporated into a sequence of steps which satisfies all required processing functions

  9. Managing Process Variants in the Process Life Cycle

    NARCIS (Netherlands)

    Hallerbach, A.; Bauer, Th.; Reichert, M.U.

    2007-01-01

    When designing process-aware information systems, often variants of the same process have to be specified. Each variant then constitutes an adjustment of a particular process to specific requirements building the process context. Current Business Process Management (BPM) tools do not adequately

  10. Applications of Process Synthesis: Moving from Conventional Chemical Processes towards Biorefinery Processes

    DEFF Research Database (Denmark)

    Yuan, Zhihong; Chen, Bingzhen; Gani, Rafiqul

    2013-01-01

    Concerns about diminishing petroleum reserves, enhanced worldwide demand for fuels and fluctuations in the global oil market, together with climate change and national security have promoted many initiatives for exploring alternative, non-petroleum based processes. Among these initiatives......, biorefinery processes for converting biomass-derived carbohydrates into transportation fuels and chemicals are now gaining more and more attention from both academia and industry. Process synthesis, which has played a vital role for the development, design and operation of (petro) chemical processes, can...

  11. Visualizing the process of process modeling with PPMCharts

    NARCIS (Netherlands)

    Claes, J.; Vanderfeesten, I.T.P.; Pinggera, J.; Reijers, H.A.; Weber, B.; Poels, G.; La Rosa, M.; Soffer, P.

    2013-01-01

    In the quest for knowledge about how to make good process models, recent research focus is shifting from studying the quality of process models to studying the process of process modeling (often abbreviated as PPM) itself. This paper reports on our efforts to visualize this specific process in such

  12. Disritmias cardíacas e alterações do segmento ST em idosos no perioperatório de ressecção transuretral da próstata sob raquianestesia: estudo comparativo Disritmias cardíacas y alteraciones del segmento ST en ancianos en el perioperatorio de resección transuretral de la próstata sobre raquianestesia: estudio comparativo Cardiac arrhythmias and ST changes in the perioperative period of elderly patients submitted to transurethral prostatectomy under spinal anesthesia: comparative study

    Directory of Open Access Journals (Sweden)

    Beatriz Lemos da Silva Mandim

    2004-04-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Idosos representam 25% do total dos pacientes cirúrgicos. Muitos pacientes com doença arterial coronariana (DAC apresentam eletrocardiograma (ECG pré-operatório normal, e alta incidência de infarto agudo do miocárdio (IAM silencioso na 1ª semana de pós-operatório. As disritmias aumentam com a idade, sendo observadas extrassístoles supraventriculares (ESSV e ventriculares (ESV, fibrilação atrial e distúrbios da condução intraventricular. O objetivo deste estudo foi avaliar a prevalência de disritmias cardíacas e de alterações do segmento ST no perioperatório através do Sistema Holter em pacientes idosos submetidos à cirurgia de ressecção transuretral da próstata (RTU e herniorrafia inguinal sob raquianestesia (controle. MÉTODO: Foram avaliados 21 pacientes com idades entre 65 e 84 anos submetidos a RTU da próstata e 16 pacientes com idades entre 65 e 86 anos, submetidos à herniorrafia inguinal, sob raquianestesia. Avaliação pelo Sistema Holter no pré-operatório (12 horas, intra-operatório (3 horas e pós-operatório (12 horas. RESULTADOS: A prevalência de extrassístoles supraventriculares (ESSV entre os grupos RTU e controle foi, no pré-operatório 85,7% vs. 93,7%, no intra-operatório 85,7% vs. 81,2% e no pós-operatório 76,2% vs. 100%. As extrassístoles ventriculares (ESV tiveram prevalência de 76,2% vs. 81,2% no pré, 80,9% vs. 68,7% no intra e 80,9% vs. 81,2% no pós-operatório. A prevalência de alterações do segmento ST entre os grupos RTU e controle foi, no pré-operatório 19% vs. 18,7%, no intra-operatório 4,7% vs. 18,7% e no pós-operatório de 14,3% vs. 18,7%, sem significância estatística. CONCLUSÕES: Os paciente idosos apresentam alta prevalência de ESSV e ESV. O número total de ESSV e ESV, e alterações do segmento ST, presentes no período pré-operatório, não foi alterado pela cirurgia de ressecção transuretral da próstata, bem como pela herniorrafia

  13. Process Intensification: A Perspective on Process Synthesis

    DEFF Research Database (Denmark)

    Lutze, Philip; Gani, Rafiqul; Woodley, John

    2010-01-01

    In recent years, process intensification (PI) has attracted considerable academic interest as a potential means for process improvement, to meet the increasing demands for sustainable production. A variety of intensified operations developed in academia and industry creates a large number...... of options to potentially improve the process but to identify the set of feasible solutions for PI in which the optimal can be found takes considerable resources. Hence, a process synthesis tool to achieve PI would potentially assist in the generation and evaluation of PI options. Currently, several process...... design tools with a clear focus on specific PI tasks exist. Therefore, in this paper, the concept of a general systematic framework for synthesis and design of PI options in hierarchical steps through analyzing an existing process, generating PI options in a superstructure and evaluating intensified...

  14. Perceptual Processing Affects Conceptual Processing

    Science.gov (United States)

    van Dantzig, Saskia; Pecher, Diane; Zeelenberg, Rene; Barsalou, Lawrence W.

    2008-01-01

    According to the Perceptual Symbols Theory of cognition (Barsalou, 1999), modality-specific simulations underlie the representation of concepts. A strong prediction of this view is that perceptual processing affects conceptual processing. In this study, participants performed a perceptual detection task and a conceptual property-verification task…

  15. A process insight repository supporting process optimization

    OpenAIRE

    Vetlugin, Andrey

    2012-01-01

    Existing solutions for analysis and optimization of manufacturing processes, such as online analysis processing or statistical calculations, have shortcomings that limit continuous process improvements. In particular, they lack means of storing and integrating the results of analysis. This makes the valuable information that can be used for process optimizations used only once and then disposed. The goal of the Advanced Manufacturing Analytics (AdMA) research project is to design an integrate...

  16. [The influence of physical exercise on heart rate variability].

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies

  17. The effect of the physical activity on polymorphic premature ventricular complexes in chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Márcio G. Kiuchi

    2017-06-01

    Full Text Available Background: Polymorphic premature ventricular complexes (PVCs are very common, appearing most frequently in patients with hypertension, obesity, sleep apnea, and structural heart disease. Sympathetic hyperactivity plays a critical role in the development, maintenance, and aggravation of ventricular arrhythmias. Endurance exercise training clearly lowers sympathetic activity in sympatho-excitatory disease states and may be tolerated by patients with chronic kidney disease (CKD. Methods: We assessed 40 CKD patients with hypertension with polymorphic PVCs. Patients underwent a complete medical history and physical examination. We evaluated the effectiveness of β blocker only or β blocker + exercise during 12 months of follow-up regarding the changes of the numbers of PVCs and mean heart rate (HR by 24-hour-Holter. Results: We observed in the β blocker group a significant decrease in the number of polymorphic PVCs from baseline 36,515 ± 3,518 to 3, 6, 9 and 12 months of follow-up, 28,314 ± 2,938, 23,709 ± 1,846, 22,564 ± 1,673, and 22,725 ± 1,415, respectively (P < 0.001. In the β blocker + exercise group a significant decrease in the number of polymorphic PVCs also occurred from baseline 36,091 ± 3,327 to 3, 6, 9 and 12 months of follow-up, 29,252 ± 3,211, 20,948 ± 2,386, 14,238 ± 3,338, and 6,225 ± 2,319, respectively (P < 0.001. Comparisons between the two groups at the same time point showed differences from the sixth month onwards: the 6th (Δ = −2,761, P = 0.045, 9th (Δ = −8,325, P < 0.001 and 12th (Δ = −16,500, P < 0.001 months. There was an improvement during the 12 months of follow-up vs. baseline, after the β blocker or β blocker + exercise in mean 24-hour HR Holter monitoring, creatinine values, eGFR, and ACR. Conclusion: Polymorphic PVCs may be modifiable by physical activity in CKD patients with hypertension without structural heart disease.

  18. Utility of heart rate turbulence and T-Wave alternans to assess risk for Re-admission and cardiac death in hospitalized heart failure patients.

    Science.gov (United States)

    Yamada, Shinya; Yoshihisa, Akiomi; Sato, Yu; Sato, Takamasa; Kamioka, Masashi; Kaneshiro, Takashi; Oikawa, Masayoshi; Kobayashi, Atsushi; Suzuki, Hitoshi; Ishida, Takafumi; Takeishi, Yasuchika

    2018-05-18

    Heart failure (HF) patients have a higher risk of recurrent HF and cardiac death, and electrical remodeling is considered to be an important factor for HF progression. The present study aimed to validate the utility of electrocardiogram and Holter monitoring for the risk stratification of HF patients. Our study comprised 215 patients (144 males, mean age 62 years) who had been hospitalized due to acute decompensated HF. Electrocardiogram (QRS duration and QTc interval) and 24-hour Holter monitoring (heart rate variability, heart rate turbulence and T-wave alternans [TWA]) were performed in stable condition before discharge. The clinical characteristics and outcomes were then investigated. During a median follow-up period of 2.7 years, there were 83 (38.6%) cardiac events (re-hospitalization due to worsening HF [n = 51] or cardiac death [n = 32]). The patients with cardiac events had a lower turbulence slope (TS) and higher TWA compared to those without cardiac events (TS, 3.0±5.5 ms/RR vs. 5.3±5.6 ms/RR, P = 0.001; TWA, 66.1±19.6 μV vs. 54.7±15.1 μV, P < 0.001). Univariable analysis showed that TS, TWA, QRS duration, and QTc interval were associated with cardiac events (P = 0.004, P < 0.001, P = 0.037 and P = 0.024, respectively), while the multivariable analysis after the adjustment of multiple confounders showed that TS and TWA were independent predictive factors of cardiac events with a hazard ratio of 0.936 and 1.015 (95% confidence interval [CI]: 0.860-0.974, P = 0.006; and 95% CI: 1.003-1.027, p = 0.016), respectively. The measurement of TS and TWA is useful for assessing risk for re-hospitalization and cardiac death in HF patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Two-stage process analysis using the process-based performance measurement framework and business process simulation

    NARCIS (Netherlands)

    Han, K.H.; Kang, J.G.; Song, M.S.

    2009-01-01

    Many enterprises have recently been pursuing process innovation or improvement to attain their performance goals. To align a business process with enterprise performances, this study proposes a two-stage process analysis for process (re)design that combines the process-based performance measurement

  20. Continuous Correctness of Business Processes Against Process Interference

    NARCIS (Netherlands)

    van Beest, Nick; Bucur, Doina

    2013-01-01

    In distributed business process support environments, process interference from multiple stakeholders may cause erroneous process outcomes. Existing solutions to detect and correct interference at runtime employ formal verification and the automatic generation of intervention processes at runtime.

  1. Process mining: making knowledge discovery process centric

    NARCIS (Netherlands)

    Aalst, van der W.M.P.

    2011-01-01

    Recently, the Task Force on Process Mining released the Process Mining Manifesto. The manifesto is supported by 53 organizations and 77 process mining experts contributed to it. The active contributions from end-users, tool vendors, consultants, analysts, and researchers illustrate the growing

  2. Business process model repositories : efficient process retrieval

    NARCIS (Netherlands)

    Yan, Z.

    2012-01-01

    As organizations increasingly work in process-oriented manner, the number of business process models that they develop and have to maintain increases. As a consequence, it has become common for organizations to have collections of hundreds or even thousands of business process models. When a

  3. Corpo estranho intracardíaco: complicação da ventriculoauriculostomia

    Directory of Open Access Journals (Sweden)

    Gilberto Machado de Almeida

    1965-09-01

    Full Text Available A ventriculoauriculostomia, apesar das complicações que pode determinar, continua a ser a técnica cirúrgica mais freqüentemente usada para o tratamento da hidrocefalia. Na literatura, existe referência a apenas três casos em que a extremidade inferior do sistema de derivação deslocou-se para o ventrículo direito. Nestes doentes o corpo estranho foi retirado ci-rùrgicamente. Apresentamos um caso operado segundo a técnica de Spitz-Holter, com embolização cardíaca pelo cateter jugular. O doente permanece há 22 meses com o corpo estranho no coração direito, porque a família não permitiu que fôsse realizada a cardiotomia.

  4. Melatonin reduces cardiac morbidity and markers of myocardial ischemia after elective abdominal aortic aneurism repair

    DEFF Research Database (Denmark)

    Gögenür, Ismail; Kücükakin, Bülent; Panduro Jensen, Leif

    2014-01-01

    The aim was to examine the effect of perioperative melatonin treatment on clinical cardiac morbidity and markers of myocardial ischemia in patients undergoing elective surgery for abdominal aortic aneurism. Reperfusion injury results in increased cardiac morbidity in patients undergoing surgery...... for abdominal aortic aneurisms (AAA). A randomized, placebo-controlled, clinical trial including patients undergoing surgery for AAA was performed. The patients received by infusion over a 2-hr period either, 50 mg melatonin or placebo intra-operatively, and 10 mg melatonin or placebo orally, the first three...... by Holter monitoring. A total of 26 patients received melatonin, while 24 received placebo. A significant reduction in cardiac morbidity was seen in the melatonin-treated patients compared with those given placebo [4% versus 29% (P = 0.02)]. Five patients (19%) who received melatonin had increased Tp...

  5. Engineered design features in the HI-STAR/HI-STORM systems to maximize ALARA, safety, and community acceptance

    International Nuclear Information System (INIS)

    Blessing, Christian

    2003-01-01

    Heltec International is a U.S. corporation headquartered in New Jersey, dedicated to providing capital goods and technical services to the power industry. Over 75 percent of the company's product output is destined for nuclear power plants. Holter counts among its active clients a majority of the nuclear plants in the United States, as well as Korea, Taiwan, Mexico, and Brazil. The company also has a growing market presence in Japan and the European Union. Leading U.S. nuclear plant owners, such as Entergy, Exelon, FPL, Southern Nuclear, PG and E and TVA have a long-term and continuous business relationship with Holtec International. This article deals with Holtec dry storage system description, the multi-purpose canister, hi-star 100 overpack, hi-storm 100 overpack and unique advantages of holtec's dry storage technology

  6. C-reactive protein, heart rate variability and prognosis in community subjects with no apparent heart disease

    DEFF Research Database (Denmark)

    Sajadieh, A; Nielsen, OW; Rasmussen, Verner

    2006-01-01

    OBJECTIVES: Increased C-reactive protein (CRP) and reduced heart rate variability (HRV) both indicate poor prognosis. An inverse association between HRV and CRP has been reported, suggesting an interaction between inflammatory and autonomic systems. However, the prognostic impact of this interact...... of four HRV measures were significantly associated with increased rate of death or myocardial infarction. In a Cox model with CRP >or=2.5 microg mL(-1), standard deviation for the mean value of the time between normal complexes...... examinations, and 24-h Holter monitoring. Four time domain measures of HRV were studied. All were prospectively followed for up to 5 years. RESULTS: Mean age was 64 years (55-75). During the follow-up, 46 total deaths and 11 cases of definite acute myocardial infarction were observed. Both CRP and three...

  7. Severe abnormal Heart Rate Turbulence Onset is associated with deterioration of liver cirrhosis

    DEFF Research Database (Denmark)

    Jansen, Christian; Al-Kassou, Baravan; Lehmann, Jennifer

    2018-01-01

    BACKGROUND: In patients with liver cirrhosis, cardiac dysfunction is frequent and is associated with increased morbidity and mortality. Cardiac dysfunction in cirrhosis seems to be linked to autonomic dysfunction. This study investigates the role of autonomic dysfunction assessed by Heart Rate...... Turbulence (HRT) analyses in patients with liver cirrhosis. METHODS AND PATIENTS: Inclusion criteria was (1) diagnosis of cirrhosis by clinical, imaging or biopsy and (2) evaluation by standard 12-lead-ECG and 24h holter monitoring and (3) at least 3 premature ventricular contractions. The exclusion...... criterion was presence of cardiac diseases, independent of liver cirrhosis. Biochemical parameters were analysed using standard methods. HRT was assessed using Turbulence onset (TO) and slope (TS). The endpoint was deterioration of liver cirrhosis defined as increased MELD and readmission for complications...

  8. Aerodynamic isotope separation processes for uranium enrichment: process requirements

    International Nuclear Information System (INIS)

    Malling, G.F.; Von Halle, E.

    1976-01-01

    The pressing need for enriched uranium to fuel nuclear power reactors, requiring that as many as ten large uranium isotope separation plants be built during the next twenty years, has inspired an increase of interest in isotope separation processes for uranium enrichment. Aerodynamic isotope separation processes have been prominently mentioned along with the gas centrifuge process and the laser isotope separation methods as alternatives to the gaseous diffusion process, currently in use, for these future plants. Commonly included in the category of aerodynamic isotope separation processes are: (a) the separation nozzle process; (b) opposed gas jets; (c) the gas vortex; (d) the separation probes; (e) interacting molecular beams; (f) jet penetration processes; and (g) time of flight separation processes. A number of these aerodynamic isotope separation processes depend, as does the gas centrifuge process, on pressure diffusion associated with curved streamlines for the basic separation effect. Much can be deduced about the process characteristics and the economic potential of such processes from a simple and elementary process model. In particular, the benefit to be gained from a light carrier gas added to the uranium feed is clearly demonstrated. The model also illustrates the importance of transient effects in this class of processes

  9. Business Process Innovation using the Process Innovation Laboratory

    DEFF Research Database (Denmark)

    Møller, Charles

    for practical applications has not been identified. The aim of this paper is to establish a conceptual framework for business process innovation in the supply chain based on advanced enterprise systems. The main approach to business process innovation in this context is to create a new methodology for exploring...... process models and patterns of applications. The paper thus presents a new concept for business process innovation called the process innovation laboratory a.k.a. the ?-Lab. The ?-Lab is a comprehensive framework for BPI using advanced enterprise systems. The ?-Lab is a collaborative workspace...... for experimenting with process models and an explorative approach to study integrated modeling in a controlled environment. The ?-Lab facilitates innovation by using an integrated action learning approach to process modeling including contemporary technological, organizational and business perspectives....

  10. Discovering Reference Process Models by Mining Process Variants

    NARCIS (Netherlands)

    Li, C.; Reichert, M.U.; Wombacher, Andreas

    Recently, a new generation of adaptive Process-Aware Information Systems (PAIS) has emerged, which allows for dynamic process and service changes (e.g., to insert, delete, and move activities and service executions in a running process). This, in turn, has led to a large number of process variants

  11. BUSINESS PROCESS REENGINEERING AS THE METHOD OF PROCESS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    O. Honcharova

    2013-09-01

    Full Text Available The article is devoted to the analysis of process management approach. The main understanding of process management approach has been researched in the article. The definition of process and process management has been given. Also the methods of business process improvement has been analyzed, among them are fast-analysis solution technology (FAST, benchmarking, reprojecting and reengineering. The main results of using business process improvement have been described in figures of reducing cycle time, costs and errors. Also the tasks of business process reengineering have been noticed. The main stages of business process reengineering have been noticed. The main efficiency results of business process reengineering and its success factors have been determined.

  12. Fundamentals of process intensification: A process systems engineering view

    DEFF Research Database (Denmark)

    Babi, Deenesh Kavi; Sales Cruz, Alfonso Mauricio; Gani, Rafiqul

    2016-01-01

    This chapter gives an overview of the fundamentals of process intensification from a process systems engineering point of view. The concept of process intensification, including process integration, is explained together with the drivers for applying process intensification, which can be achieved...

  13. Idaho Chemical Processing Plant Process Efficiency improvements

    International Nuclear Information System (INIS)

    Griebenow, B.

    1996-03-01

    In response to decreasing funding levels available to support activities at the Idaho Chemical Processing Plant (ICPP) and a desire to be cost competitive, the Department of Energy Idaho Operations Office (DOE-ID) and Lockheed Idaho Technologies Company have increased their emphasis on cost-saving measures. The ICPP Effectiveness Improvement Initiative involves many activities to improve cost effectiveness and competitiveness. This report documents the methodology and results of one of those cost cutting measures, the Process Efficiency Improvement Activity. The Process Efficiency Improvement Activity performed a systematic review of major work processes at the ICPP to increase productivity and to identify nonvalue-added requirements. A two-phase approach was selected for the activity to allow for near-term implementation of relatively easy process modifications in the first phase while obtaining long-term continuous improvement in the second phase and beyond. Phase I of the initiative included a concentrated review of processes that had a high potential for cost savings with the intent of realizing savings in Fiscal Year 1996 (FY-96.) Phase II consists of implementing long-term strategies too complex for Phase I implementation and evaluation of processes not targeted for Phase I review. The Phase II effort is targeted for realizing cost savings in FY-97 and beyond

  14. Process Accounting

    OpenAIRE

    Gilbertson, Keith

    2002-01-01

    Standard utilities can help you collect and interpret your Linux system's process accounting data. Describes the uses of process accounting, standard process accounting commands, and example code that makes use of process accounting utilities.

  15. Modeling of biopharmaceutical processes. Part 2: Process chromatography unit operation

    DEFF Research Database (Denmark)

    Kaltenbrunner, Oliver; McCue, Justin; Engel, Philip

    2008-01-01

    Process modeling can be a useful tool to aid in process development, process optimization, and process scale-up. When modeling a chromatography process, one must first select the appropriate models that describe the mass transfer and adsorption that occurs within the porous adsorbent. The theoret......Process modeling can be a useful tool to aid in process development, process optimization, and process scale-up. When modeling a chromatography process, one must first select the appropriate models that describe the mass transfer and adsorption that occurs within the porous adsorbent...

  16. Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices.

    Science.gov (United States)

    Gambi, Ennio; Agostinelli, Angela; Belli, Alberto; Burattini, Laura; Cippitelli, Enea; Fioretti, Sandro; Pierleoni, Paola; Ricciuti, Manola; Sbrollini, Agnese; Spinsante, Susanna

    2017-08-02

    Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects' normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject's lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account.

  17. Generalized Ornstein-Uhlenbeck processes and associated self-similar processes

    CERN Document Server

    Lim, S C

    2003-01-01

    We consider three types of generalized Ornstein-Uhlenbeck processes: the stationary process obtained from the Lamperti transformation of fractional Brownian motion, the process with stretched exponential covariance and the process obtained from the solution of the fractional Langevin equation. These stationary Gaussian processes have many common properties, such as the fact that their local covariances share a similar structure and they exhibit identical spectral densities at large frequency limit. In addition, the generalized Ornstein-Uhlenbeck processes can be shown to be local stationary representations of fractional Brownian motion. Two new self-similar Gaussian processes, in addition to fractional Brownian motion, are obtained by applying the (inverse) Lamperti transformation to the generalized Ornstein-Uhlenbeck processes. We study some of the properties of these self-similar processes such as the long-range dependence. We give a simulation of their sample paths based on numerical Karhunan-Loeve expansi...

  18. Generalized Ornstein-Uhlenbeck processes and associated self-similar processes

    International Nuclear Information System (INIS)

    Lim, S C; Muniandy, S V

    2003-01-01

    We consider three types of generalized Ornstein-Uhlenbeck processes: the stationary process obtained from the Lamperti transformation of fractional Brownian motion, the process with stretched exponential covariance and the process obtained from the solution of the fractional Langevin equation. These stationary Gaussian processes have many common properties, such as the fact that their local covariances share a similar structure and they exhibit identical spectral densities at large frequency limit. In addition, the generalized Ornstein-Uhlenbeck processes can be shown to be local stationary representations of fractional Brownian motion. Two new self-similar Gaussian processes, in addition to fractional Brownian motion, are obtained by applying the (inverse) Lamperti transformation to the generalized Ornstein-Uhlenbeck processes. We study some of the properties of these self-similar processes such as the long-range dependence. We give a simulation of their sample paths based on numerical Karhunan-Loeve expansion

  19. From Process Understanding to Process Control

    NARCIS (Netherlands)

    Streefland, M.

    2010-01-01

    A licensed pharmaceutical process is required to be executed within the validated ranges throughout the lifetime of product manufacturing. Changes to the process usually require the manufacturer to demonstrate that the safety and efficacy of the product remains unchanged. Recent changes in the

  20. Integrated Process Modeling-A Process Validation Life Cycle Companion.

    Science.gov (United States)

    Zahel, Thomas; Hauer, Stefan; Mueller, Eric M; Murphy, Patrick; Abad, Sandra; Vasilieva, Elena; Maurer, Daniel; Brocard, Cécile; Reinisch, Daniela; Sagmeister, Patrick; Herwig, Christoph

    2017-10-17

    During the regulatory requested process validation of pharmaceutical manufacturing processes, companies aim to identify, control, and continuously monitor process variation and its impact on critical quality attributes (CQAs) of the final product. It is difficult to directly connect the impact of single process parameters (PPs) to final product CQAs, especially in biopharmaceutical process development and production, where multiple unit operations are stacked together and interact with each other. Therefore, we want to present the application of Monte Carlo (MC) simulation using an integrated process model (IPM) that enables estimation of process capability even in early stages of process validation. Once the IPM is established, its capability in risk and criticality assessment is furthermore demonstrated. IPMs can be used to enable holistic production control strategies that take interactions of process parameters of multiple unit operations into account. Moreover, IPMs can be trained with development data, refined with qualification runs, and maintained with routine manufacturing data which underlines the lifecycle concept. These applications will be shown by means of a process characterization study recently conducted at a world-leading contract manufacturing organization (CMO). The new IPM methodology therefore allows anticipation of out of specification (OOS) events, identify critical process parameters, and take risk-based decisions on counteractions that increase process robustness and decrease the likelihood of OOS events.

  1. PC image processing

    International Nuclear Information System (INIS)

    Hwa, Mok Jin Il; Am, Ha Jeng Ung

    1995-04-01

    This book starts summary of digital image processing and personal computer, and classification of personal computer image processing system, digital image processing, development of personal computer and image processing, image processing system, basic method of image processing such as color image processing and video processing, software and interface, computer graphics, video image and video processing application cases on image processing like satellite image processing, color transformation of image processing in high speed and portrait work system.

  2. Meat Processing.

    Science.gov (United States)

    Legacy, Jim; And Others

    This publication provides an introduction to meat processing for adult students in vocational and technical education programs. Organized in four chapters, the booklet provides a brief overview of the meat processing industry and the techniques of meat processing and butchering. The first chapter introduces the meat processing industry and…

  3. Process for improving metal production in steelmaking processes

    Science.gov (United States)

    Pal, Uday B.; Gazula, Gopala K. M.; Hasham, Ali

    1996-01-01

    A process and apparatus for improving metal production in ironmaking and steelmaking processes is disclosed. The use of an inert metallic conductor in the slag containing crucible and the addition of a transition metal oxide to the slag are the disclosed process improvements.

  4. Genetic Process Mining: Alignment-based Process Model Mutation

    NARCIS (Netherlands)

    Eck, van M.L.; Buijs, J.C.A.M.; Dongen, van B.F.; Fournier, F.; Mendling, J.

    2015-01-01

    The Evolutionary Tree Miner (ETM) is a genetic process discovery algorithm that enables the user to guide the discovery process based on preferences with respect to four process model quality dimensions: replay fitness, precision, generalization and simplicity. Traditionally, the ETM algorithm uses

  5. Business process modeling for processing classified documents using RFID technology

    Directory of Open Access Journals (Sweden)

    Koszela Jarosław

    2016-01-01

    Full Text Available The article outlines the application of the processing approach to the functional description of the designed IT system supporting the operations of the secret office, which processes classified documents. The article describes the application of the method of incremental modeling of business processes according to the BPMN model to the description of the processes currently implemented (“as is” in a manual manner and target processes (“to be”, using the RFID technology for the purpose of their automation. Additionally, the examples of applying the method of structural and dynamic analysis of the processes (process simulation to verify their correctness and efficiency were presented. The extension of the process analysis method is a possibility of applying the warehouse of processes and process mining methods.

  6. Novel process windows, part 1: Boosted micro process technology

    NARCIS (Netherlands)

    Hessel, V.; Wang, Q.

    2011-01-01

    Novel Process Windows (NPW) is the use of highly intensified, unusual and typically harsh process conditions to boost micro process technology and flow chemistry for the production of high-added value fine chemicals, pharmaceuticals, etc.. It is far from conventional processing and also from

  7. Cognitive Processes in Discourse Comprehension: Passive Processes, Reader-Initiated Processes, and Evolving Mental Representations

    Science.gov (United States)

    van den Broek, Paul; Helder, Anne

    2017-01-01

    As readers move through a text, they engage in various types of processes that, if all goes well, result in a mental representation that captures their interpretation of the text. With each new text segment the reader engages in passive and, at times, reader-initiated processes. These processes are strongly influenced by the readers'…

  8. Data processing

    CERN Document Server

    Fry, T F

    2013-01-01

    Data Processing discusses the principles, practices, and associated tools in data processing. The book is comprised of 17 chapters that are organized into three parts. The first part covers the characteristics, systems, and methods of data processing. Part 2 deals with the data processing practice; this part discusses the data input, output, and storage. The last part discusses topics related to systems and software in data processing, which include checks and controls, computer language and programs, and program elements and structures. The text will be useful to practitioners of computer-rel

  9. In-process and post-process measurements of drill wear for control of the drilling process

    Science.gov (United States)

    Liu, Tien-I.; Liu, George; Gao, Zhiyu

    2011-12-01

    Optical inspection was used in this research for the post-process measurements of drill wear. A precision toolmakers" microscope was used. Indirect index, cutting force, is used for in-process drill wear measurements. Using in-process measurements to estimate the drill wear for control purpose can decrease the operation cost and enhance the product quality and safety. The challenge is to correlate the in-process cutting force measurements with the post-process optical inspection of drill wear. To find the most important feature, the energy principle was used in this research. It is necessary to select only the cutting force feature which shows the highest sensitivity to drill wear. The best feature selected is the peak of torque in the drilling process. Neuro-fuzzy systems were used for correlation purposes. The Adaptive-Network-Based Fuzzy Inference System (ANFIS) can construct fuzzy rules with membership functions to generate an input-output pair. A 1x6 ANFIS architecture with product of sigmoid membership functions can in-process measure the drill wear with an error as low as 0.15%. This is extremely important for control of the drilling process. Furthermore, the measurement of drill wear was performed under different drilling conditions. This shows that ANFIS has the capability of generalization.

  10. Quasi-Birth-and-Death Processes with Rational Arrival Process Components

    DEFF Research Database (Denmark)

    Bean, Nigel G.; Nielsen, Bo Friis

    to develop an analytic method for such a process, that parallels the analysis of a traditional QBD. We demonstrate the analysis by considering a queue where the arrival process and the sequence of service times are derived from two different RAPs that are not just Markovian Arrival processes. We also...... introduce an element of correlation between the arrival process and the sequence of service times.......In this paper we introduce the concept of a Quasi-Birth-and-Death process (QBD) with Rational Arrival Process components. We use the physical interpretation of a Rational Arrival Process (RAP), developed by Asmussen and Bladt, to consider such a Markov process. We exploit this interpretation...

  11. Processes subject to integrated pollution control. Petroleum processes: oil refining and associated processes

    International Nuclear Information System (INIS)

    1995-01-01

    This document, part of a series offering guidance on pollution control regulations issued by Her Majesty's Inspectorate of Pollution, (HMIP) focuses on petroleum processes such as oil refining and other associated processes. The various industrial processes used, their associated pollution release routes into the environment and techniques for controlling these releases are all discussed. Environmental quality standards are related to national and international agreements on pollution control and abatement. HMIP's work on air, water and land pollution monitoring is also reported. (UK)

  12. Reflow process stabilization by chemical characteristics and process conditions

    Science.gov (United States)

    Kim, Myoung-Soo; Park, Jeong-Hyun; Kim, Hak-Joon; Kim, Il-Hyung; Jeon, Jae-Ha; Gil, Myung-Goon; Kim, Bong-Ho

    2002-07-01

    With the shrunken device rule below 130nm, the patterning of smaller contact hole with enough process margin is required for mass production. Therefore, shrinking technology using thermal reflow process has been applied for smaller contact hole formation. In this paper, we have investigated the effects of chemical characteristics such as molecular weight, blocking ratio of resin, cross-linker amount and solvent type with its composition to reflow process of resist and found the optimized chemical composition for reflow process applicable condition. And several process conditions like resist coating thickness and multi-step thermal reflow method have been also evaluated to stabilize the pattern profile and improve CD uniformity after reflow process. From the experiment results, it was confirmed that the effect of crosslinker in resist to reflow properties such as reflow temperature and reflow rate were very critical and it controlled the pattern profile during reflow processing. And also, it showed stable CD uniformity and improved resist properties for top loss, film shrinkage and etch selectivity. The application of lower coating thickness of resist induced symmetric pattern profile even at edge with wider process margin. The introduction of two-step baking method for reflow process showed uniform CD value, also. It is believed that the application of resist containing crosslinker and optimized process conditions for smaller contact hole patterning is necessary for the mass production with a design rule below 130nm.

  13. Microcrystalline silicon deposition: Process stability and process control

    International Nuclear Information System (INIS)

    Donker, M.N. van den; Kilper, T.; Grunsky, D.; Rech, B.; Houben, L.; Kessels, W.M.M.; Sanden, M.C.M. van de

    2007-01-01

    Applying in situ process diagnostics, we identified several process drifts occurring in the parallel plate plasma deposition of microcrystalline silicon (μc-Si:H). These process drifts are powder formation (visible from diminishing dc-bias and changing spatial emission profile on a time scale of 10 0 s), transient SiH 4 depletion (visible from a decreasing SiH emission intensity on a time scale of 10 2 s), plasma heating (visible from an increasing substrate temperature on a time scale of 10 3 s) and a still puzzling long-term drift (visible from a decreasing SiH emission intensity on a time scale of 10 4 s). The effect of these drifts on the crystalline volume fraction in the deposited films is investigated by selected area electron diffraction and depth-profiled Raman spectroscopy. An example shows how the transient depletion and long-term drift can be prevented by suitable process control. Solar cells deposited using this process control show enhanced performance. Options for process control of plasma heating and powder formation are discussed

  14. The permanent process

    DEFF Research Database (Denmark)

    Møller, Jesper; McCullagh, Peter

    We extend the boson process first to a large class of Cox processes and second an even larger class of infinitely divisible point processes. Density and moment results are studied in detail. These results are obtained in closed form as weighted permanents, so the extension is called a permanent...... process. Temporal extensions and a particularly tractable case of the permanent process are also studied. Extensions of the ferminon process along similar lines, leading to so-called determinant processes, are discussed at the end. While the permanent process is attractive, the determinant process...

  15. Multidimensional process discovery

    NARCIS (Netherlands)

    Ribeiro, J.T.S.

    2013-01-01

    Typically represented in event logs, business process data describe the execution of process events over time. Business process intelligence (BPI) techniques such as process mining can be applied to get strategic insight into business processes. Process discovery, conformance checking and

  16. Process development

    Energy Technology Data Exchange (ETDEWEB)

    Schuegerl, K

    1984-01-01

    The item 'process development' comprises the production of acetonic/butonal with C. acetobylicum and the yeasting of potato waste. The target is to increase productivity by taking the following measures - optimation of media, on-line process analysis, analysis of reaction, mathematic modelling and identification of parameters, process simulation, development of a state estimator with the help of the on-line process analysis and the model, optimization and adaptive control.

  17. Echocardiographic and clinical findings in patients with Fabry disease during long-term enzyme replacement therapy

    DEFF Research Database (Denmark)

    Madsen, Christoffer Valdorff; Bundgaard, Henning; Rasmussen, Åse Krogh

    2017-01-01

    from baseline to follow-up; 30 mm [15-53] vs. 25 mm [3-44], p vs. 1520 mm·ms [550-5740], p within the non-ERT group. During follow-up, cardiac symptoms and use of cardiovascular procedures and -medication increased...... significantly in the ERT group, whereas no differences were observed within the non-ERT group. DISCUSSION: We raise concerns regarding the efficacy and benefit of ERT on cardiac involvement in Fabry disease and stress the need for further research....... and Holter-monitoring. RESULTS: We included 66 patients; 47 patients (27 women) received ERT (ERT group) and 19 patients (15 women) did not (non-ERT group). The groups were followed for a median of 8 [0-12] years and 6 [0-13] years, respectively. Comparison between ERT and non-ERT receiving patients by left...

  18. Influence of heavy cigarette smoking on heart rate variability and heart rate turbulence parameters

    DEFF Research Database (Denmark)

    Cagirci, Goksel; Cay, Serkan; Karakurt, Ozlem

    2009-01-01

    BACKGROUND: Cigarette smoking increases the risk of cardiovascular events related with several mechanisms. The most suggested mechanism is increased activity of sympathetic nervous system. Heart rate variability (HRV) and heart rate turbulence (HRT) has been shown to be independent and powerful......, 69 subjects and nonsmokers 74 subjects (control group) were enrolled in this study. HRV and HRT analyses [turbulence onset (TO) and turbulence slope (TS)] were assessed from 24-hour Holter recordings. RESULTS: The values of TO were significantly higher in heavy cigarette smokers than control group...... (-1.150 +/- 4.007 vs -2.454 +/- 2.796, P = 0.025, respectively), but values of TS were not statistically different between two groups (10.352 +/- 7.670 vs 9.613 +/- 7.245, P = 0.555, respectively). Also, the number of patients who had abnormal TO was significantly higher in heavy cigarette smokers...

  19. New descriptors of T-wave morphology are independent of heart rate

    DEFF Research Database (Denmark)

    Andersen, Mads Peter; Xue, Joel Q; Graff, Claus

    2008-01-01

    from daytime Holter recordings. Duration parameters (QT, ToTe, TpTe, and others), a number of basic T-wave morphology parameters (amplitude, area, and others) as well as advanced morphology descriptors (asymmetry, flatness, and others) were measured automatically. Heart rate dependence was examined...... by means of analysis of covariance. The results showed clear heart rate dependence for the QT interval (R(2) = 0.53-0.57) and a moderate degree of heart rate dependence for the basic morphology parameters (amplitude, area, and others) (R(2) = 0.17-0.42). Both the advanced T-wave descriptors (asymmetry......T-wave morphology descriptors are sensitive to drug-induced changes and may be a useful addition to the QT interval in cardiac safety trials. Intrasubject heart rate dependence of T-wave morphology was investigated in a sample of 39 healthy individuals. Ten-second electrocardiograms were obtained...

  20. Autonomic dysfunction and impaired cerebral autoregulation in cirrhosis

    DEFF Research Database (Denmark)

    Frøkjaer, Vibe G; Strauss, Gitte I; Mehlsen, Jesper

    2006-01-01

    Cerebral blood flow autoregulation is lost in patients with severe liver cirrhosis. The cause of this is unknown. We determined whether autonomic dysfunction was related to impaired cerebral autoregulation in patients with cirrhosis. Fourteen patients with liver cirrhosis and 11 healthy volunteers...... were recruited. Autonomic function was assessed in response to deep breathing, head-up tilt and during 24-h Holter monitoring. Cerebral autoregulation was assessed by determining the change in mean cerebral blood flow velocity (MCAVm, transcranial Doppler) during an increase in blood pressure induced...... by norepinephrine infusion (NE). The severity of liver disease was assessed using the Child-Pugh scale (class A, mild; class B, moderate; class C, severe liver dysfunction).NE increased blood pressure similarly in the controls (27 (24-32) mmHg) and patients with the most severe liver cirrhosis (Child-Pugh C, 31 (26...

  1. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...... analyzed. In adjusted analyses, significant associations (standard deviation of normal-to-normal [NN] intervals [SDNN]: p = .043; standard deviation of NN intervals over 5-min periods [SDANN]: p = .010) and a trend (HRV triangular index: p = .09) were found for Type D personality, and trends were found...... = .043). A Benjamini-Hochberg correction for multiple testing led to reduction of the number of significant relationships, but there was still support for lower autonomic control patients with Type D personality and depression. Future research with larger sample sizes is warranted....

  2. Statistical Process Control for KSC Processing

    Science.gov (United States)

    Ford, Roger G.; Delgado, Hector; Tilley, Randy

    1996-01-01

    The 1996 Summer Faculty Fellowship Program and Kennedy Space Center (KSC) served as the basis for a research effort into statistical process control for KSC processing. The effort entailed several tasks and goals. The first was to develop a customized statistical process control (SPC) course for the Safety and Mission Assurance Trends Analysis Group. The actual teaching of this course took place over several weeks. In addition, an Internet version of the same course complete with animation and video excerpts from the course when it was taught at KSC was developed. The application of SPC to shuttle processing took up the rest of the summer research project. This effort entailed the evaluation of SPC use at KSC, both present and potential, due to the change in roles for NASA and the Single Flight Operations Contractor (SFOC). Individual consulting on SPC use was accomplished as well as an evaluation of SPC software for KSC use in the future. A final accomplishment of the orientation of the author to NASA changes, terminology, data format, and new NASA task definitions will allow future consultation when the needs arise.

  3. A method for manufacturing a tool part for an injection molding process, a hot embossing process, a nano-imprint process, or an extrusion process

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a method for manufacturing a tool part for an injection molding process, a hot embossing process, nano-imprint process or an extrusion process. First, there is provided a master structure (10) with a surface area comprising nanometre-sized protrusions (11...

  4. Process control using modern systems of information processing

    International Nuclear Information System (INIS)

    Baldeweg, F.

    1984-01-01

    Modern digital automation techniques allow the application of demanding types of process control. These types of process control are characterized by their belonging to higher levels in a multilevel model. Functional and technical aspects of the performance of digital automation plants are presented and explained. A modern automation system is described considering special procedures of process control (e.g. real time diagnosis)

  5. DUAL-PROCESS, a highly reliable process control system

    International Nuclear Information System (INIS)

    Buerger, L.; Gossanyi, A.; Parkanyi, T.; Szabo, G.; Vegh, E.

    1983-02-01

    A multiprocessor process control system is described. During its development the reliability was the most important aspect because it is used in the computerized control of a 5 MW research reactor. DUAL-PROCESS is fully compatible with the earlier single processor control system PROCESS-24K. The paper deals in detail with the communication, synchronization, error detection and error recovery problems of the operating system. (author)

  6. Quasi-Birth-and-Death Processes with Rational Arrival Process Components

    DEFF Research Database (Denmark)

    Bean, Nigel G.; Nielsen, Bo Friis

    2010-01-01

    This paper introduces the concept of a Quasi-Birth-and-Death process (QBD) with Rational Arrival Process (RAP) components. We use the physical interpretation of the prediction process of the RAP, developed by Asmussen and Bladt, and develop an analysis that parallels the analysis of a traditional...... QBD. Further, we present an algorithm for the numerical evaluation of the matrix G. As an example, we consider two queues where the arrival process and the sequence of service times are taken from two dependent RAPs, that are not Markovian Arrival Processes......This paper introduces the concept of a Quasi-Birth-and-Death process (QBD) with Rational Arrival Process (RAP) components. We use the physical interpretation of the prediction process of the RAP, developed by Asmussen and Bladt, and develop an analysis that parallels the analysis of a traditional...

  7. Stochastic processes

    CERN Document Server

    Parzen, Emanuel

    1962-01-01

    Well-written and accessible, this classic introduction to stochastic processes and related mathematics is appropriate for advanced undergraduate students of mathematics with a knowledge of calculus and continuous probability theory. The treatment offers examples of the wide variety of empirical phenomena for which stochastic processes provide mathematical models, and it develops the methods of probability model-building.Chapter 1 presents precise definitions of the notions of a random variable and a stochastic process and introduces the Wiener and Poisson processes. Subsequent chapters examine

  8. Dosimetry and process control for radiation processing

    International Nuclear Information System (INIS)

    Mod Ali, N.

    2002-01-01

    Complete text of publication follows. Accurate radiation dosimetry can provide quality assurance in radiation processing. Considerable relevant experiences in dosimetry by the SSDL-MINT has necessitate the development of methods making measurement at gamma plant traceable to the national standard. It involves the establishment of proper calibration procedure and selection of appropriate transfer system/technique to assure adequate traceability to a primary radiation standard. The effort forms the basis for irradiation process control, the legal approval of the process by the public health authorities (medical product sterilization and food preservation) and the safety and acceptance of the product

  9. Process mining using BPMN: relating event logs and process models

    NARCIS (Netherlands)

    Kalenkova, A.A.; van der Aalst, W.M.P.; Lomazova, I.A.; Rubin, V.A.

    2017-01-01

    Process-aware information systems (PAIS) are systems relying on processes, which involve human and software resources to achieve concrete goals. There is a need to develop approaches for modeling, analysis, improvement and monitoring processes within PAIS. These approaches include process mining

  10. Process mining using BPMN : relating event logs and process models

    NARCIS (Netherlands)

    Kalenkova, A.A.; Aalst, van der W.M.P.; Lomazova, I.A.; Rubin, V.A.

    2015-01-01

    Process-aware information systems (PAIS) are systems relying on processes, which involve human and software resources to achieve concrete goals. There is a need to develop approaches for modeling, analysis, improvement and monitoring processes within PAIS. These approaches include process mining

  11. Process modeling for Humanities: tracing and analyzing scientific processes

    OpenAIRE

    Hug , Charlotte; Salinesi , Camille; Deneckere , Rebecca; Lamasse , Stéphane

    2011-01-01

    International audience; This paper concerns epistemology and the understanding of research processes in Humanities, such as Archaeology. We believe that to properly understand research processes, it is essential to trace them. The collected traces depend on the process model established, which has to be as accurate as possible to exhaustively record the traces. In this paper, we briefly explain why the existing process models for Humanities are not sufficient to represent traces. We then pres...

  12. Poisson processes

    NARCIS (Netherlands)

    Boxma, O.J.; Yechiali, U.; Ruggeri, F.; Kenett, R.S.; Faltin, F.W.

    2007-01-01

    The Poisson process is a stochastic counting process that arises naturally in a large variety of daily life situations. We present a few definitions of the Poisson process and discuss several properties as well as relations to some well-known probability distributions. We further briefly discuss the

  13. Process improvement : the creation and evaluation of process alternatives

    NARCIS (Netherlands)

    Netjes, M.

    2010-01-01

    Companies continuously strive to improve their processes to increase productivity and delivered quality against lower costs. With Business Process Redesign (BPR) projects such improvement goals can be achieved. BPR involves the restructuring of business processes, stimulated by the application of

  14. The permanental process

    DEFF Research Database (Denmark)

    McCullagh, Peter; Møller, Jesper

    2006-01-01

    We extend the boson process first to a large class of Cox processes and second to an even larger class of infinitely divisible point processes. Density and moment results are studied in detail. These results are obtained in closed form as weighted permanents, so the extension i called a permanental...... process. Temporal extensions and a particularly tractable case of the permanental process are also studied. Extensions of the fermion process along similar lines, leading to so-called determinantal processes, are discussed....

  15. Dry process potentials

    International Nuclear Information System (INIS)

    Faugeras, P.

    1997-01-01

    Various dry processes have been studied and more or less developed in order particularly to reduce the waste quantities but none of them had replaced the PUREX process, for reasons departing to policy errors, un-appropriate demonstration examples or too late development, although realistic and efficient dry processes such as a fluoride selective volatility based processes have been demonstrated in France (CLOVIS, ATILA) and would be ten times cheaper than the PUREX process. Dry processes could regain interest in case of a nuclear revival (following global warming fears) or thermal wastes over-production. In the near future, dry processes could be introduced in complement to the PUREX process, especially at the end of the process cycle, for a more efficient recycling and safer storage (inactivation)

  16. Business Process Customization using Process Merging Techniques

    NARCIS (Netherlands)

    Bulanov, Pavel; Lazovik, Alexander; Aiello, Marco

    2012-01-01

    One of the important application of service composition techniques lies in the field of business process management. Essentially a business process can be considered as a composition of services, which is usually prepared by domain experts, and many tasks still have to be performed manually. These

  17. Business process transformation the process tangram framework

    CERN Document Server

    Sharma, Chitra

    2015-01-01

    This book presents a framework through transformation and explains  how business goals can be translated into realistic plans that are tangible and yield real results in terms of the top line and the bottom line. Process Transformation is like a tangram puzzle, which has multiple solutions yet is essentially composed of seven 'tans' that hold it together. Based on practical experience and intensive research into existing material, 'Process Tangram' is a simple yet powerful framework that proposes Process Transformation as a program. The seven 'tans' are: the transformation program itself, triggers, goals, tools and techniques, culture, communication and success factors. With its segregation into tans and division into core elements, this framework makes it possible to use 'pick and choose' to quickly and easily map an organization's specific requirements. Change management and process modeling are covered in detail. In addition, the book approaches managed services as a model of service delivery, which it ex...

  18. Composable Data Processing in Environmental Science - A Process View

    NARCIS (Netherlands)

    Wombacher, Andreas

    Data processing in environmental science is essential for doing science. The heterogeneity of data sources, data processing operations and infrastructures results in a lot of manual data and process integration work done by each scientist individually. This is very inefficient and time consuming.

  19. Processing module operating methods, processing modules, and communications systems

    Science.gov (United States)

    McCown, Steven Harvey; Derr, Kurt W.; Moore, Troy

    2014-09-09

    A processing module operating method includes using a processing module physically connected to a wireless communications device, requesting that the wireless communications device retrieve encrypted code from a web site and receiving the encrypted code from the wireless communications device. The wireless communications device is unable to decrypt the encrypted code. The method further includes using the processing module, decrypting the encrypted code, executing the decrypted code, and preventing the wireless communications device from accessing the decrypted code. Another processing module operating method includes using a processing module physically connected to a host device, executing an application within the processing module, allowing the application to exchange user interaction data communicated using a user interface of the host device with the host device, and allowing the application to use the host device as a communications device for exchanging information with a remote device distinct from the host device.

  20. Improving the process of process modelling by the use of domain process patterns

    NARCIS (Netherlands)

    Koschmider, A.; Reijers, H.A.

    2015-01-01

    The use of business process models has become prevalent in a wide area of enterprise applications. But while their popularity is expanding, concerns are growing with respect to their proper creation and maintenance. An obvious way to boost the efficiency of creating high-quality business process

  1. Trends in business process analysis: from verification to process mining

    NARCIS (Netherlands)

    Aalst, van der W.M.P.; Cardoso, J.; Cordeiro, J.; Filipe, J.

    2007-01-01

    Business process analysis ranges from model verification at design-time to the monitoring of processes at runtime. Much progress has been achieved in process verification. Today we are able to verify the entire reference model of SAP without any problems. Moreover, more and more processes leave

  2. Automatic extraction of process categories from process model collections

    NARCIS (Netherlands)

    Malinova, M.; Dijkman, R.M.; Mendling, J.; Lohmann, N.; Song, M.; Wohed, P.

    2014-01-01

    Many organizations build up their business process management activities in an incremental way. As a result, there is no overarching structure defined at the beginning. However, as business process modeling initiatives often yield hundreds to thousands of process models, there is a growing need for

  3. Opportunities and challenges for process control in process intensification

    NARCIS (Netherlands)

    Nikacevic, N.M.; Huesman, A.E.M.; Hof, Van den P.M.J.; Stankiewicz, A.

    2012-01-01

    This is a review and position article discussing the role and prospective for process control in process intensification. Firstly, the article outlines the classical role of control in process systems, presenting an overview of control systems’ development, from basic PID control to the advanced

  4. Transforming spatial point processes into Poisson processes using random superposition

    DEFF Research Database (Denmark)

    Møller, Jesper; Berthelsen, Kasper Klitgaaard

    with a complementary spatial point process Y  to obtain a Poisson process X∪Y  with intensity function β. Underlying this is a bivariate spatial birth-death process (Xt,Yt) which converges towards the distribution of (X,Y). We study the joint distribution of X and Y, and their marginal and conditional distributions....... In particular, we introduce a fast and easy simulation procedure for Y conditional on X. This may be used for model checking: given a model for the Papangelou intensity of the original spatial point process, this model is used to generate the complementary process, and the resulting superposition is a Poisson...... process with intensity function β if and only if the true Papangelou intensity is used. Whether the superposition is actually such a Poisson process can easily be examined using well known results and fast simulation procedures for Poisson processes. We illustrate this approach to model checking...

  5. Process/Equipment Co-Simulation on Syngas Chemical Looping Process

    Energy Technology Data Exchange (ETDEWEB)

    Zeng, Liang; Zhou, Qiang; Fan, Liang-Shih

    2012-09-30

    The chemical looping strategy for fossil energy applications promises to achieve an efficient energy conversion system for electricity, liquid fuels, hydrogen and/or chemicals generation, while economically separate CO{sub 2} by looping reaction design in the process. Chemical looping particle performance, looping reactor engineering, and process design and applications are the key drivers to the success of chemical looping process development. In order to better understand and further scale up the chemical looping process, issues such as cost, time, measurement, safety, and other uncertainties need to be examined. To address these uncertainties, advanced reaction/reactor modeling and process simulation are highly desired and the modeling efforts can accelerate the chemical looping technology development, reduce the pilot-scale facility design time and operating campaigns, as well as reduce the cost and technical risks. The purpose of this work is thus to conduct multiscale modeling and simulations on the key aspects of chemical looping technology, including particle reaction kinetics, reactor design and operation, and process synthesis and optimization.

  6. Process Fragment Libraries for Easier and Faster Development of Process-based Applications

    Directory of Open Access Journals (Sweden)

    David Schumm

    2011-01-01

    Full Text Available The term “process fragment” is recently gaining momentum in business process management research. We understand a process fragment as a connected and reusable process structure, which has relaxed completeness and consistency criteria compared to executable processes. We claim that process fragments allow for an easier and faster development of process-based applications. As evidence to this claim we present a process fragment concept and show a sample collection of concrete, real-world process fragments. We present advanced application scenarios for using such fragments in development of process-based applications. Process fragments are typically managed in a repository, forming a process fragment library. On top of a process fragment library from previous work, we discuss the potential impact of using process fragment libraries in cross-enterprise collaboration and application integration.

  7. Rapid thermal processing and beyond applications in semiconductor processing

    CERN Document Server

    Lerch, W

    2008-01-01

    Heat-treatment and thermal annealing are very common processing steps which have been employed during semiconductor manufacturing right from the beginning of integrated circuit technology. In order to minimize undesired diffusion, and other thermal budget-dependent effects, the trend has been to reduce the annealing time sharply by switching from standard furnace batch-processing (involving several hours or even days), to rapid thermal processing involving soaking times of just a few seconds. This transition from thermal equilibrium, to highly non-equilibrium, processing was very challenging a

  8. Fractional Processes and Fractional-Order Signal Processing Techniques and Applications

    CERN Document Server

    Sheng, Hu; Qiu, TianShuang

    2012-01-01

    Fractional processes are widely found in science, technology and engineering systems. In Fractional Processes and Fractional-order Signal Processing, some complex random signals, characterized by the presence of a heavy-tailed distribution or non-negligible dependence between distant observations (local and long memory), are introduced and examined from the ‘fractional’ perspective using simulation, fractional-order modeling and filtering and realization of fractional-order systems. These fractional-order signal processing (FOSP) techniques are based on fractional calculus, the fractional Fourier transform and fractional lower-order moments. Fractional Processes and Fractional-order Signal Processing: • presents fractional processes of fixed, variable and distributed order studied as the output of fractional-order differential systems; • introduces FOSP techniques and the fractional signals and fractional systems point of view; • details real-world-application examples of FOSP techniques to demonstr...

  9. Clinical Processes - The Killer Application for Constraint-Based Process Interactions

    DEFF Research Database (Denmark)

    Jiménez-Ramírez, Andrés; Barba, Irene; Reichert, Manfred

    2018-01-01

    . The scenario is subject to complex temporal constraints and entails the need for coordinating the constraint-based interactions among the processes related to a patient treatment process. As demonstrated in this work, the selected real process scenario can be suitably modeled through a declarative approach....... examples. However, to the best of our knowledge, they have not been used to model complex, real-world scenarios that comprise constraints going beyond control-flow. In this paper, we propose the use of a declarative language for modeling a sophisticated healthcare process scenario from the real world......For more than a decade, the interest in aligning information systems in a process-oriented way has been increasing. To enable operational support for business processes, the latter are usually specified in an imperative way. The resulting process models, however, tend to be too rigid to meet...

  10. Process innovation laboratory

    DEFF Research Database (Denmark)

    Møller, Charles

    2007-01-01

    to create a new methodology for developing and exploring process models and applications. The paper outlines the process innovation laboratory as a new approach to BPI. The process innovation laboratory is a comprehensive framework and a collaborative workspace for experimenting with process models....... The process innovation laboratory facilitates innovation by using an integrated action learning approach to process modelling in a controlled environment. The study is based on design science and the paper also discusses the implications to EIS research and practice......Most organizations today are required not only to operate effective business processes but also to allow for changing business conditions at an increasing rate. Today nearly every business relies on their enterprise information systems (EIS) for process integration and future generations of EIS...

  11. Membrane processes

    Science.gov (United States)

    Staszak, Katarzyna

    2017-11-01

    The membrane processes have played important role in the industrial separation process. These technologies can be found in all industrial areas such as food, beverages, metallurgy, pulp and paper, textile, pharmaceutical, automotive, biotechnology and chemical industry, as well as in water treatment for domestic and industrial application. Although these processes are known since twentieth century, there are still many studies that focus on the testing of new membranes' materials and determining of conditions for optimal selectivity, i. e. the optimum transmembrane pressure (TMP) or permeate flux to minimize fouling. Moreover the researchers proposed some calculation methods to predict the membrane processes properties. In this article, the laboratory scale experiments of membrane separation techniques, as well their validation by calculation methods are presented. Because membrane is the "heart" of the process, experimental and computational methods for its characterization are also described.

  12. PROPOSAL OF SPATIAL OPTIMIZATION OF PRODUCTION PROCESS IN PROCESS DESIGNER

    Directory of Open Access Journals (Sweden)

    Peter Malega

    2015-03-01

    Full Text Available This contribution is focused on optimizing the use of space in the production process using software Process Designer. The aim of this contribution is to suggest possible improvements to the existing layout of the selected production process. Production process was analysed in terms of inputs, outputs and course of actions. Nowadays there are many software solutions aimed at optimizing the use of space. One of these software products is the Process Designer, which belongs to the product line Tecnomatix. This software is primarily aimed at production planning. With Process Designer is possible to design the layout of production and subsequently to analyse the production or to change according to the current needs of the company.

  13. Process automation

    International Nuclear Information System (INIS)

    Moser, D.R.

    1986-01-01

    Process automation technology has been pursued in the chemical processing industries and to a very limited extent in nuclear fuel reprocessing. Its effective use has been restricted in the past by the lack of diverse and reliable process instrumentation and the unavailability of sophisticated software designed for process control. The Integrated Equipment Test (IET) facility was developed by the Consolidated Fuel Reprocessing Program (CFRP) in part to demonstrate new concepts for control of advanced nuclear fuel reprocessing plants. A demonstration of fuel reprocessing equipment automation using advanced instrumentation and a modern, microprocessor-based control system is nearing completion in the facility. This facility provides for the synergistic testing of all chemical process features of a prototypical fuel reprocessing plant that can be attained with unirradiated uranium-bearing feed materials. The unique equipment and mission of the IET facility make it an ideal test bed for automation studies. This effort will provide for the demonstration of the plant automation concept and for the development of techniques for similar applications in a full-scale plant. A set of preliminary recommendations for implementing process automation has been compiled. Some of these concepts are not generally recognized or accepted. The automation work now under way in the IET facility should be useful to others in helping avoid costly mistakes because of the underutilization or misapplication of process automation. 6 figs

  14. Process Analytical Technology (PAT): batch-to-batch reproducibility of fermentation processes by robust process operational design and control.

    Science.gov (United States)

    Gnoth, S; Jenzsch, M; Simutis, R; Lübbert, A

    2007-10-31

    The Process Analytical Technology (PAT) initiative of the FDA is a reaction on the increasing discrepancy between current possibilities in process supervision and control of pharmaceutical production processes and its current application in industrial manufacturing processes. With rigid approval practices based on standard operational procedures, adaptations of production reactors towards the state of the art were more or less inhibited for long years. Now PAT paves the way for continuous process and product improvements through improved process supervision based on knowledge-based data analysis, "Quality-by-Design"-concepts, and, finally, through feedback control. Examples of up-to-date implementations of this concept are presented. They are taken from one key group of processes in recombinant pharmaceutical protein manufacturing, the cultivations of genetically modified Escherichia coli bacteria.

  15. Defense Waste Processing Facility Process Simulation Package Life Cycle

    International Nuclear Information System (INIS)

    Reuter, K.

    1991-01-01

    The Defense Waste Processing Facility (DWPF) will be used to immobilize high level liquid radioactive waste into safe, stable, and manageable solid form. The complexity and classification of the facility requires that a performance based operator training to satisfy Department of Energy orders and guidelines. A major portion of the training program will be the application and utilization of Process Simulation Packages to assist in training the Control Room Operators on the fluctionality of the process and the application of the Distribution Control System (DCS) in operating and managing the DWPF process. The packages are being developed by the DWPF Computer and Information Systems Simulation Group. This paper will describe the DWPF Process Simulation Package Life Cycle. The areas of package scope, development, validation, and configuration management will be reviewed and discussed in detail

  16. Comparative process mining in education : an approach based on process cubes

    NARCIS (Netherlands)

    van der Aalst, W.M.P.; Guo, S.; Gorissen, P.J.B.; Ceravolo, P.; Accorsi, R.; Cudre-Mauroux, P.

    2015-01-01

    Process mining techniques enable the analysis of a wide variety of processes using event data. For example, event logs can be used to automatically learn a process model (e.g., a Petri net or BPMN model). Next to the automated discovery of the real underlying process, there are process mining

  17. Process mining

    DEFF Research Database (Denmark)

    van der Aalst, W.M.P.; Rubin, V.; Verbeek, H.M.W.

    2010-01-01

    Process mining includes the automated discovery of processes from event logs. Based on observed events (e.g., activities being executed or messages being exchanged) a process model is constructed. One of the essential problems in process mining is that one cannot assume to have seen all possible...... behavior. At best, one has seen a representative subset. Therefore, classical synthesis techniques are not suitable as they aim at finding a model that is able to exactly reproduce the log. Existing process mining techniques try to avoid such “overfitting” by generalizing the model to allow for more...... support for it). None of the existing techniques enables the user to control the balance between “overfitting” and “underfitting”. To address this, we propose a two-step approach. First, using a configurable approach, a transition system is constructed. Then, using the “theory of regions”, the model...

  18. Process monitoring

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Many of the measurements and observations made in a nuclear processing facility to monitor processes and product quality can also be used to monitor the location and movements of nuclear materials. In this session information is presented on how to use process monitoring data to enhance nuclear material control and accounting (MC and A). It will be seen that SNM losses can generally be detected with greater sensitivity and timeliness and point of loss localized more closely than by conventional MC and A systems if process monitoring data are applied. The purpose of this session is to enable the participants to: (1) identify process unit operations that could improve control units for monitoring SNM losses; (2) choose key measurement points and formulate a loss indicator for each control unit; and (3) describe how the sensitivities and timeliness of loss detection could be determined for each loss indicator

  19. Metacognition in Creativity: Process Awareness Used to Facilitate the Creative Process

    DEFF Research Database (Denmark)

    Valgeirsdóttir, Dagný; Onarheim, Balder

    2017-01-01

    to ensure capture of all instances of process awareness. Through this iterative process it was revealed that process awareness was predominantly observed in creativity related tasks. Moreover three distinct facets to process awareness emerged; planning, monitoring and reflecting, which were employed...... respectively before, during and after initiating a process and/or a workshop. We conclude that process awareness is an important creativity skill, being a crucial mechanism to enhance all stages of the creative process. If a designer becomes able to plan, monitor and reflect on his or her own cognitive...... processes, as well as other team members, he or she will be able to understand what works and what does not for advancing the creative process. In turn, that enables the designer to become more strategic about which actions are appropriate and at what time they are most usefully deployed; making the use...

  20. Development of functionally-oriented technological processes of electroerosive processing

    Science.gov (United States)

    Syanov, S. Yu

    2018-03-01

    The stages of the development of functionally oriented technological processes of electroerosive processing from the separation of the surfaces of parts and their service functions to the determination of the parameters of the process of electric erosion, which will provide not only the quality parameters of the surface layer, but also the required operational properties, are described.

  1. Data processing

    International Nuclear Information System (INIS)

    Cousot, P.

    1988-01-01

    The 1988 progress report of the Data Processing laboratory (Polytechnic School, France), is presented. The laboratory research fields are: the semantics, the tests and the semantic analysis of the codes, the formal calculus, the software applications, the algorithms, the neuron networks and VLSI (Very Large Scale Integration). The investigations concerning the polynomial rings are performed by means of the standard basis approach. Among the research topics, the Pascal codes, the parallel processing, the combinatorial, statistical and asymptotic properties of the fundamental data processing tools, the signal processing and the pattern recognition. The published papers, the congress communications and the thesis are also included [fr

  2. PROCESS VARIABILITY REDUCTION THROUGH STATISTICAL PROCESS CONTROL FOR QUALITY IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    B.P. Mahesh

    2010-09-01

    Full Text Available Quality has become one of the most important customer decision factors in the selection among the competing product and services. Consequently, understanding and improving quality is a key factor leading to business success, growth and an enhanced competitive position. Hence quality improvement program should be an integral part of the overall business strategy. According to TQM, the effective way to improve the Quality of the product or service is to improve the process used to build the product. Hence, TQM focuses on process, rather than results as the results are driven by the processes. Many techniques are available for quality improvement. Statistical Process Control (SPC is one such TQM technique which is widely accepted for analyzing quality problems and improving the performance of the production process. This article illustrates the step by step procedure adopted at a soap manufacturing company to improve the Quality by reducing process variability using Statistical Process Control.

  3. Emotional Processing, Interaction Process, and Outcome in Clarification-Oriented Psychotherapy for Personality Disorders: A Process-Outcome Analysis.

    Science.gov (United States)

    Kramer, Ueli; Pascual-Leone, Antonio; Rohde, Kristina B; Sachse, Rainer

    2016-06-01

    It is important to understand the change processes involved in psychotherapies for patients with personality disorders (PDs). One patient process that promises to be useful in relation to the outcome of psychotherapy is emotional processing. In the present process-outcome analysis, we examine this question by using a sequential model of emotional processing and by additionally taking into account a therapist's appropriate responsiveness to a patient's presentation in clarification-oriented psychotherapy (COP), a humanistic-experiential form of therapy. The present study involved 39 patients with a range of PDs undergoing COP. Session 25 was assessed as part of the working phase of each therapy by external raters in terms of emotional processing using the Classification of Affective-Meaning States (CAMS) and in terms of the overall quality of therapist-patient interaction using the Process-Content-Relationship Scale (BIBS). Treatment outcome was assessed pre- and post-therapy using the Global Severity Index (GSI) of the SCL-90-R and the BDI. Results indicate that the good outcome cases showed more self-compassion, more rejecting anger, and a higher quality of therapist-patient interaction compared to poorer outcome cases. For good outcome cases, emotional processing predicted 18% of symptom change at the end of treatment, which was not found for poor outcome cases. These results are discussed within the framework of an integrative understanding of emotional processing as an underlying mechanism of change in COP, and perhaps in other effective therapy approaches for PDs.

  4. Process Materialization Using Templates and Rules to Design Flexible Process Models

    Science.gov (United States)

    Kumar, Akhil; Yao, Wen

    The main idea in this paper is to show how flexible processes can be designed by combining generic process templates and business rules. We instantiate a process by applying rules to specific case data, and running a materialization algorithm. The customized process instance is then executed in an existing workflow engine. We present an architecture and also give an algorithm for process materialization. The rules are written in a logic-based language like Prolog. Our focus is on capturing deeper process knowledge and achieving a holistic approach to robust process design that encompasses control flow, resources and data, as well as makes it easier to accommodate changes to business policy.

  5. Thin film processes

    CERN Document Server

    Vossen, John L

    1978-01-01

    Remarkable advances have been made in recent years in the science and technology of thin film processes for deposition and etching. It is the purpose of this book to bring together tutorial reviews of selected filmdeposition and etching processes from a process viewpoint. Emphasis is placed on the practical use of the processes to provide working guidelines for their implementation, a guide to the literature, and an overview of each process.

  6. Screening and managing obstructive sleep apnoea in nocturnal heart block patients: an observational study.

    Science.gov (United States)

    Wu, Xu; Liu, Zilong; Chang, Su Chi; Fu, Cuiping; Li, Wenjing; Jiang, Hong; Jiang, Liyan; Li, Shanqun

    2016-02-16

    Nocturnal heart block often occurs in patients with obstructive sleep apnoea (OSA). It is more likely to be undiagnosed in heart block patients who are ignorant of the symptoms of sleep disorder. Berlin Questionnaire (BQ) is a highly reliable way to discover the risk factors of OSA, whereas the validity in sleep-related heart block patients is uncertain. We performed an observational study to address these issues and confirmed the potential protective effect of continuous positive airway pressure (CPAP). Patients who were previously diagnosed with nocturnal heart block with R-R pauses exceeding 2 seconds were retrospective screened from the ECG centre of Zhongshan hospital. These recruited participants completed Berlin Questionnaire and underwent polysomnography synchronously with 24-hour Holter monitoring. A cross-sectional analysis was performed to confirm the association between nocturnal arrhythmia and OSA, as well as to assess the diagnostic accuracy of the BQ. Subsequently, subjects diagnosed with OSA (apnoea-hypopnoea index > 5) underwent 3 consecutive days of CPAP therapy. On the third day, patients repeated 24-hour Holter monitoring within the institution of CPAP. The symptoms of disruptive snoring and hypersomnolence in 72 enrolled patients were more related to the occurrence of nocturnal heart block (r = 0.306, 0.226, respectively, p = 0.015, 0.019) than syncope (r = 0.134, p = 0.282) and palpitations (r = 0.106, p = 0.119), which were prominent trait of our study population. The sensitivity, specificity, positive and negative predictive value of the BQ at a cut-off point of 5 of AHI for detecting OSA in heart block patients was 81.0 %, 44.4 %, 91.07 % and 25 %. Nocturnal heart block does not appear to occur exclusively in severe sleep apnoea. The frequent occurrence of arrhythmias in prominent oxygen desaturation supports the correlation between them. CPAP therapy resulted in significant decrease in the average number of

  7. Partial processing

    International Nuclear Information System (INIS)

    1978-11-01

    This discussion paper considers the possibility of applying to the recycle of plutonium in thermal reactors a particular method of partial processing based on the PUREX process but named CIVEX to emphasise the differences. The CIVEX process is based primarily on the retention of short-lived fission products. The paper suggests: (1) the recycle of fission products with uranium and plutonium in thermal reactor fuel would be technically feasible; (2) it would, however, take ten years or more to develop the CIVEX process to the point where it could be launched on a commercial scale; (3) since the majority of spent fuel to be reprocessed this century will have been in storage for ten years or more, the recycling of short-lived fission products with the U-Pu would not provide an effective means of making refabrication fuel ''inaccessible'' because the radioactivity associated with the fission products would have decayed. There would therefore be no advantage in partial processing

  8. Assessment of Process Capability: the case of Soft Drinks Processing Unit

    Science.gov (United States)

    Sri Yogi, Kottala

    2018-03-01

    The process capability studies have significant impact in investigating process variation which is important in achieving product quality characteristics. Its indices are to measure the inherent variability of a process and thus to improve the process performance radically. The main objective of this paper is to understand capability of the process being produced within specification of the soft drinks processing unit, a premier brands being marketed in India. A few selected critical parameters in soft drinks processing: concentration of gas volume, concentration of brix, torque of crock has been considered for this study. Assessed some relevant statistical parameters: short term capability, long term capability as a process capability indices perspective. For assessment we have used real time data of soft drinks bottling company which is located in state of Chhattisgarh, India. As our research output suggested reasons for variations in the process which is validated using ANOVA and also predicted Taguchi cost function, assessed also predicted waste monetarily this shall be used by organization for improving process parameters. This research work has substantially benefitted the organization in understanding the various variations of selected critical parameters for achieving zero rejection.

  9. Perturbed GUE Minor Process and Warren's Process with Drifts

    Science.gov (United States)

    Ferrari, Patrik L.; Frings, René

    2014-01-01

    We consider the minor process of (Hermitian) matrix diffusions with constant diagonal drifts. At any given time, this process is determinantal and we provide an explicit expression for its correlation kernel. This is a measure on the Gelfand-Tsetlin pattern that also appears in a generalization of Warren's process (Electron. J. Probab. 12:573-590, 2007), in which Brownian motions have level-dependent drifts. Finally, we show that this process arises in a diffusion scaling limit from an interacting particle system in the anisotropic KPZ class in 2+1 dimensions introduced in Borodin and Ferrari (Commun. Math. Phys., 2008). Our results generalize the known results for the zero drift situation.

  10. Integrated stationary Ornstein-Uhlenbeck process, and double integral processes

    Science.gov (United States)

    Abundo, Mario; Pirozzi, Enrica

    2018-03-01

    We find a representation of the integral of the stationary Ornstein-Uhlenbeck (ISOU) process in terms of Brownian motion Bt; moreover, we show that, under certain conditions on the functions f and g , the double integral process (DIP) D(t) = ∫βt g(s) (∫αs f(u) dBu) ds can be thought as the integral of a suitable Gauss-Markov process. Some theoretical and application details are given, among them we provide a simulation formula based on that representation by which sample paths, probability densities and first passage times of the ISOU process are obtained; the first-passage times of the DIP are also studied.

  11. Integrating textual and model-based process descriptions for comprehensive process search

    NARCIS (Netherlands)

    Leopold, Henrik; van der Aa, Han; Pittke, Fabian; Raffel, Manuel; Mendling, Jan; Reijers, Hajo A.

    2016-01-01

    Documenting business processes using process models is common practice in many organizations. However, not all process information is best captured in process models. Hence, many organizations complement these models with textual descriptions that specify additional details. The problem with this

  12. Neurological evidence linguistic processes precede perceptual simulation in conceptual processing.

    Science.gov (United States)

    Louwerse, Max; Hutchinson, Sterling

    2012-01-01

    There is increasing evidence from response time experiments that language statistics and perceptual simulations both play a role in conceptual processing. In an EEG experiment we compared neural activity in cortical regions commonly associated with linguistic processing and visual perceptual processing to determine to what extent symbolic and embodied accounts of cognition applied. Participants were asked to determine the semantic relationship of word pairs (e.g., sky - ground) or to determine their iconic relationship (i.e., if the presentation of the pair matched their expected physical relationship). A linguistic bias was found toward the semantic judgment task and a perceptual bias was found toward the iconicity judgment task. More importantly, conceptual processing involved activation in brain regions associated with both linguistic and perceptual processes. When comparing the relative activation of linguistic cortical regions with perceptual cortical regions, the effect sizes for linguistic cortical regions were larger than those for the perceptual cortical regions early in a trial with the reverse being true later in a trial. These results map upon findings from other experimental literature and provide further evidence that processing of concept words relies both on language statistics and on perceptual simulations, whereby linguistic processes precede perceptual simulation processes.

  13. Silicon integrated circuit process

    International Nuclear Information System (INIS)

    Lee, Jong Duck

    1985-12-01

    This book introduces the process of silicon integrated circuit. It is composed of seven parts, which are oxidation process, diffusion process, ion implantation process such as ion implantation equipment, damage, annealing and influence on manufacture of integrated circuit and device, chemical vapor deposition process like silicon Epitaxy LPCVD and PECVD, photolithography process, including a sensitizer, spin, harden bake, reflection of light and problems related process, infrared light bake, wet-etch, dry etch, special etch and problems of etching, metal process like metal process like metal-silicon connection, aluminum process, credibility of aluminum and test process.

  14. Silicon integrated circuit process

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Duck

    1985-12-15

    This book introduces the process of silicon integrated circuit. It is composed of seven parts, which are oxidation process, diffusion process, ion implantation process such as ion implantation equipment, damage, annealing and influence on manufacture of integrated circuit and device, chemical vapor deposition process like silicon Epitaxy LPCVD and PECVD, photolithography process, including a sensitizer, spin, harden bake, reflection of light and problems related process, infrared light bake, wet-etch, dry etch, special etch and problems of etching, metal process like metal process like metal-silicon connection, aluminum process, credibility of aluminum and test process.

  15. Industrial processing versus home processing of tomato sauce

    NARCIS (Netherlands)

    Tomas, Merve; Beekwilder, Jules; Hall, Robert D.; Sagdic, Osman; Boyacioglu, Dilek; Capanoglu, Esra

    2017-01-01

    The effect of industrial and home processing, in vitro gastrointestinal digestion, individual phenolic content, and antioxidant capacity of tomato into tomato sauce were investigated. Industrial processing of tomato fruit into sauce had an overall positive effect on the total antioxidant capacity

  16. Genetic process mining

    NARCIS (Netherlands)

    Aalst, van der W.M.P.; Alves De Medeiros, A.K.; Weijters, A.J.M.M.; Ciardo, G.; Darondeau, P.

    2005-01-01

    The topic of process mining has attracted the attention of both researchers and tool vendors in the Business Process Management (BPM) space. The goal of process mining is to discover process models from event logs, i.e., events logged by some information system are used to extract information about

  17. Marshaling and Acquiring Resources for the Process Improvement Process

    Science.gov (United States)

    1993-06-01

    stakeholders. ( Geber , 1990) D. IDENTIFYING SUPPLIERS Suppliers are just as crucial to setting requirements for processes as are customers. Although...output ( Geber , 1990, p. 32). Before gathering resources for process improvement, the functional manager must ensure that the relationship of internal...him patent information and clerical people process his applications. ( Geber , 1990, pp. 29-34) To get the full benefit of a white-collar worker as a

  18. Process for recovering uranium from wet process phosphoric acid (III)

    International Nuclear Information System (INIS)

    Pyrih, R.Z.; Rickard, R.S.; Carrington, O.F.

    1983-01-01

    Uranium is conventionally recovered from wet-process phosphoric acid by two liquid ion exchange steps using a mixture of mono- and disubstituted phenyl esters of orthophosphoric acid (OPPA). Efficiency of the process drops as the mono-OPPA is lost preferentially to the aqueous phase. This invention provides a process for the removal of the uranium process organics (OPPA and organic solvents) from the raffinate of the first liquid ion exchange step and their return to the circuit. The process organics are removed by a combination flotation and absorption step, which results in the recovery of the organics on beads of a hydrophobic styrene polymer

  19. Extensible packet processing architecture

    Science.gov (United States)

    Robertson, Perry J.; Hamlet, Jason R.; Pierson, Lyndon G.; Olsberg, Ronald R.; Chun, Guy D.

    2013-08-20

    A technique for distributed packet processing includes sequentially passing packets associated with packet flows between a plurality of processing engines along a flow through data bus linking the plurality of processing engines in series. At least one packet within a given packet flow is marked by a given processing engine to signify by the given processing engine to the other processing engines that the given processing engine has claimed the given packet flow for processing. A processing function is applied to each of the packet flows within the processing engines and the processed packets are output on a time-shared, arbitered data bus coupled to the plurality of processing engines.

  20. Process intensification on membrane-based process for blackcurrant juice concentration

    DEFF Research Database (Denmark)

    Fjerbæk Søtoft, Lene; Rong, Ben-Guang; Christensen, Knud Villy

    Juice concentrate production is a field where process intensification and novel concentration processes need to be implemented. The paper presents a systematic approach for process synthesis based on membrane processes for the concentration of blackcurrant juice, exemplified by the aroma recovery...... using combinations of vacuum membrane distillation and traditional distillation. Furthermore, the paper further suggests a novel method for the combination of nanofiltration, reverse osmosis and membrane distillation for the concentration of the dearomatized juice....

  1. Application of various technological processes in red clover seed processing

    OpenAIRE

    Đokić, Dragoslav; Stanisavljević, Rade; Terzić, Dragan; Marković, Jordan; Radivojević, Gordana; Anđelković, Bojan; Barać, Saša

    2012-01-01

    This paper presents the results of the processing of natural red clover seed on the processing equipment using different technological methods. Red clover seed, for the establishment and crop utilization, must be of high purity, germination, and high genetic values. These requirements are achieved by processing, or removing impurities and poor quality seeds. Red clover seed processing involves a number of operations, of which the most important are: cleaning, packaging, labeling and storage. ...

  2. CO-PRODUCT ENHANCEMENT AND DEVELOPMENT FOR THE MASADA OXYNOL PROCESS PROCESS

    Energy Technology Data Exchange (ETDEWEB)

    Donald V. Watkins

    2010-06-14

    The focus of this project was an overall process improvement through the enhancement of the co-product streams. The enhancement of the process operations and co-products will increase both ethanol production and the value of other process outputs and reduces the amount of waste byproducts. This leads to a more economical and environmentally sound alternative to landfill disposal of municipal solid waste (MSW). These enhancements can greatly increase the commercial potential for the production of ethanol from MSW by the Masada CES OxyNol process. Both technological and economical issues were considered for steps throughout the conversion process. The research efforts of this project are varied but synergistic. The project investigated many of the operations involved in the Masada process with the overall goal of process improvements. The general goal of the testing was to improve co-product quality, improve conversions efficiencies, minimize process losses, increase energy efficiency, and mitigate process and commercialization risks. The project was divided into 16 subtasks as described in general terms below. All these tasks are interrelated but not necessarily interdependent.

  3. Modeling the Object-Oriented Software Process: OPEN and the Unified Process

    NARCIS (Netherlands)

    van den Berg, Klaas; Aksit, Mehmet; van den Broek, P.M.

    A short introduction to software process modeling is presented, particularly object-oriented modeling. Two major industrial process models are discussed: the OPEN model and the Unified Process model. In more detail, the quality assurance in the Unified Process tool (formally called Objectory) is

  4. Links between attachment and social information processing: examination of intergenerational processes.

    Science.gov (United States)

    Dykas, Matthew J; Ehrlich, Katherine B; Cassidy, Jude

    2011-01-01

    This chapter describes theory and research on intergenerational connections between parents' attachment and children's social information processing, as well as between parents' social information processing and children's attachment. The chapter begins with a discussion of attachment theorists' early insights into the role that social information processing plays in attachment processes. Next, current theory about the mechanisms through which cross-generational links between attachment and social information processing might emerge is presented. The central proposition is that the quality of attachment and/or the social information processing of the parent contributes to the quality of attachment and/or social information processing in the child, and these links emerge through mediating processes related to social learning, open communication, gate-keeping, emotion regulation, and joint attention. A comprehensive review of the literature is then presented. The chapter ends with the presentation of a current theoretical perspective and suggestions for future empirical and clinical endeavors.

  5. A Repeatable Collaboration Process for Exploring Business Process Improvement Alternatives

    NARCIS (Netherlands)

    Sol, H G; Amiyo, Mercy; Nabukenya, J.

    2012-01-01

    The dynamic nature of organisations has increased demand for business process agility leading to the adoption of continuous Business Process Improvement (BPI). Success of BPI projects calls for continuous process analysis and exploration of several improvement alternatives. These activities are

  6. Processing approaches to cognition: the impetus from the levels-of-processing framework.

    Science.gov (United States)

    Roediger, Henry L; Gallo, David A; Geraci, Lisa

    2002-01-01

    Processing approaches to cognition have a long history, from act psychology to the present, but perhaps their greatest boost was given by the success and dominance of the levels-of-processing framework. We review the history of processing approaches, and explore the influence of the levels-of-processing approach, the procedural approach advocated by Paul Kolers, and the transfer-appropriate processing framework. Processing approaches emphasise the procedures of mind and the idea that memory storage can be usefully conceptualised as residing in the same neural units that originally processed information at the time of encoding. Processing approaches emphasise the unity and interrelatedness of cognitive processes and maintain that they can be dissected into separate faculties only by neglecting the richness of mental life. We end by pointing to future directions for processing approaches.

  7. Editorial: "Business process intelligence : connecting data and processes"

    NARCIS (Netherlands)

    Aalst, van der W.M.P.; Zhao, J.L.; Wang, H.; Wang, Harry Jiannan

    2015-01-01

    This introduction to the special issue on Business Process Intelligence (BPI) discusses the relation between data and processes. The recent attention for Big Data illustrates that organizations are aware of the potential of the torrents of data generated by today's information systems. However, at

  8. Modeling the Object-Oriented Software Process: OPEN and the Unified Process

    OpenAIRE

    van den Berg, Klaas; Aksit, Mehmet; van den Broek, P.M.

    1999-01-01

    A short introduction to software process modeling is presented, particularly object-oriented modeling. Two major industrial process models are discussed: the OPEN model and the Unified Process model. In more detail, the quality assurance in the Unified Process tool (formally called Objectory) is reviewed.

  9. Process modelling on a canonical basis[Process modelling; Canonical modelling

    Energy Technology Data Exchange (ETDEWEB)

    Siepmann, Volker

    2006-12-20

    Based on an equation oriented solving strategy, this thesis investigates a new approach to process modelling. Homogeneous thermodynamic state functions represent consistent mathematical models of thermodynamic properties. Such state functions of solely extensive canonical state variables are the basis of this work, as they are natural objective functions in optimisation nodes to calculate thermodynamic equilibrium regarding phase-interaction and chemical reactions. Analytical state function derivatives are utilised within the solution process as well as interpreted as physical properties. By this approach, only a limited range of imaginable process constraints are considered, namely linear balance equations of state variables. A second-order update of source contributions to these balance equations is obtained by an additional constitutive equation system. These equations are general dependent on state variables and first-order sensitivities, and cover therefore practically all potential process constraints. Symbolic computation technology efficiently provides sparsity and derivative information of active equations to avoid performance problems regarding robustness and computational effort. A benefit of detaching the constitutive equation system is that the structure of the main equation system remains unaffected by these constraints, and a priori information allows to implement an efficient solving strategy and a concise error diagnosis. A tailor-made linear algebra library handles the sparse recursive block structures efficiently. The optimisation principle for single modules of thermodynamic equilibrium is extended to host entire process models. State variables of different modules interact through balance equations, representing material flows from one module to the other. To account for reusability and encapsulation of process module details, modular process modelling is supported by a recursive module structure. The second-order solving algorithm makes it

  10. EFFECT OF BRONCHODILATORS ON HEART RATE VARIABILITY IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE

    Directory of Open Access Journals (Sweden)

    H. H. Shugushev

    2015-12-01

    Full Text Available Aim. To study effect of long-acting theophylline (Theotard, KRKA and combination of salmeterol and fluticasone (Seretide, GlaxoSmithKline on heart rhythm variability (HRV and number of arrhythmic episodes in patients with chronic obstructive pulmonary disease (COPD.Material and methods. 144 patients with COPD and 35 patients of control group were examined. The analysis of HRV and Holter monitoring were made f on 2th and 14th days.Results. Treatment with both drugs led to increase in power of low- and high frequencies and their ratio (LF/HF, decrease in rate of supraventricular and ventricular arrhythmias. Theophylline therapy raised in a number of single and pair supraventricular extrasystoles. Treatment with combination of salmeterol and fluticasone did not change a number of extrasystoles.Conclusion. Combination of salmeterol and fluticasone is more preferable as a broncholytic therapy for patients with COPD and heart rhythm disorders.

  11. [Cardiac sarcoidosis: diagnostics, treatment and follow-up].

    Science.gov (United States)

    Dudziak, Maria; Jankowska, Hanna; Dorniak, Karolina

    2018-03-27

    Sarcoidosis is a generalised granulomatous disorder of unknown aetiology. Cardiac involvement may affect conduction system, myocardium, valvular apparatus and pericardium. Clinical spectrum ranges from asymptomatic involvement to sudden cardiac death. Patients with biopsy-proven extracardiac sarcoidosis should be screened for cardiac involvement (standard ECG, 24-hour Holter ECG, echocardiography) and in case of any abnormalities found on these tests, more advanced diagnostic methods should be used. Steroid treatment is still the mainstay of therapy in cardiac sarcoidosis. Several immunosuppresive agents are also effective and used in different combinations with steroids, as well as heart failure treatment (including ACE inhibitors, angiotensin receptor blockers, beta-blockers and diuretics). Advanced heart block requires pacemaker implantation, and implantable cardioverterdefibrillator is an effective treatment in primary and secondary prophylaxis of sudden cardiac death. Heart transplantation is considered in advanced, drug-resistant heart failure or incessant ventricular arrhythmias unresponsive to other forms of therapy. © 2018 MEDPRESS.

  12. Neurocardiogenic Syncope and Supraventricular Tachycardia in Association with a Rare Congenital Aortic Valve Abnormality

    Directory of Open Access Journals (Sweden)

    Yashwant Agrawal

    2016-01-01

    Full Text Available We report a case of a 26-year-old woman who presented with multiple episodes of syncope over a five-months period of time. Transthoracic echocardiogram had shown a normal functioning quadricuspid aortic valve (QAV which was also confirmed on a transesophageal echocardiogram. Computed tomographic angiography of heart and coronary arteries showed the QAV with equal size of all aortic cusps and normal coronary arteries. Intermittent chest pain and palpitations warranted an exercise stress test. The stress test revealed normal aerobic exertion, with achievement of 101% of maximal peak heart rate. However, during peak stress, we noted a drop in her blood pressure significantly resulting in dizziness. No arrhythmias were noted during the stress test. With recurrent syncope episodes and palpitations, Holter monitoring was done, revealing supraventricular tachycardia (SVT. We discuss current available literature and coassociations with QAV. New association of QAV with SVT needs further analysis.

  13. Uranium enrichment. Enrichment processes

    International Nuclear Information System (INIS)

    Alexandre, M.; Quaegebeur, J.P.

    2009-01-01

    Despite the remarkable progresses made in the diversity and the efficiency of the different uranium enrichment processes, only two industrial processes remain today which satisfy all of enriched uranium needs: the gaseous diffusion and the centrifugation. This article describes both processes and some others still at the demonstration or at the laboratory stage of development: 1 - general considerations; 2 - gaseous diffusion: physical principles, implementation, utilisation in the world; 3 - centrifugation: principles, elementary separation factor, flows inside a centrifuge, modeling of separation efficiencies, mechanical design, types of industrial centrifuges, realisation of cascades, main characteristics of the centrifugation process; 4 - aerodynamic processes: vortex process, nozzle process; 5 - chemical exchange separation processes: Japanese ASAHI process, French CHEMEX process; 6 - laser-based processes: SILVA process, SILMO process; 7 - electromagnetic and ionic processes: mass spectrometer and calutron, ion cyclotron resonance, rotating plasmas; 8 - thermal diffusion; 9 - conclusion. (J.S.)

  14. Science-based information processing in the process control of power stations

    International Nuclear Information System (INIS)

    Weisang, C.

    1992-01-01

    Through the application of specialized systems, future-orientated information processing integrates the sciences of processes, control systems, process control strategies, user behaviour and ergonomics. Improvements in process control can be attained, inter alia, by the preparation of the information contained (e.g. by suppressing the flow of signals and replacing it with signals which are found on substance) and also by an ergonomic representation of the study of the process. (orig.) [de

  15. Process mining: discovering direct successors in process logs

    NARCIS (Netherlands)

    Maruster, L.; Weijters, A.J.M.M.; Aalst, van der W.M.P.; Bosch, van den A.P.J.; Lange, S.; Satoh, K.; Smith, C.H.

    2002-01-01

    Workflow management technology requires the existence of explicit process models, i.e. a completely specified workflow design needs to be developed in order to enact a given workflow process. Such a workflow design is time consuming and often subjective and incomplete. We propose a learning method

  16. Internal process: what is abstraction and distortion process?

    Science.gov (United States)

    Fiantika, F. R.; Budayasa, I. K.; Lukito, A.

    2018-03-01

    Geometry is one of the branch of mathematics that plays a major role in the development of science and technology. Thus, knowing the geometry concept is needed for students from their early basic level of thinking. A preliminary study showed that the elementary students have difficulty in perceiving parallelogram shape in a 2-dimention of a cube drawing as a square shape. This difficulty makes the students can not solve geometrical problems correctly. This problem is related to the internal thinking process in geometry. We conducted the exploration of students’ internal thinking processes in geometry particularly in distinguishing the square and parallelogram shape. How the students process their internal thinking through distortion and abstraction is the main aim of this study. Analysis of the geometrical test and deep interview are used in this study to obtain the data. The result of this study is there are two types of distortion and abstraction respectively in which the student used in their internal thinking processes.

  17. Nonaqueous processing methods

    International Nuclear Information System (INIS)

    Coops, M.S.; Bowersox, D.F.

    1984-09-01

    A high-temperature process utilizing molten salt extraction from molten metal alloys has been developed for purification of spent power reactor fuels. Experiments with laboratory-scale processing operations show that purification and throughput parameters comparable to the Barnwell Purex process can be achieved by pyrochemical processing in equipment one-tenth the size, with all wastes being discharged as stable metal alloys at greatly reduced volume and disposal cost. This basic technology can be developed for large-scale processing of spent reactor fuels. 13 references, 4 figures

  18. Transforming Collaborative Process Models into Interface Process Models by Applying an MDA Approach

    Science.gov (United States)

    Lazarte, Ivanna M.; Chiotti, Omar; Villarreal, Pablo D.

    Collaborative business models among enterprises require defining collaborative business processes. Enterprises implement B2B collaborations to execute these processes. In B2B collaborations the integration and interoperability of processes and systems of the enterprises are required to support the execution of collaborative processes. From a collaborative process model, which describes the global view of the enterprise interactions, each enterprise must define the interface process that represents the role it performs in the collaborative process in order to implement the process in a Business Process Management System. Hence, in this work we propose a method for the automatic generation of the interface process model of each enterprise from a collaborative process model. This method is based on a Model-Driven Architecture to transform collaborative process models into interface process models. By applying this method, interface processes are guaranteed to be interoperable and defined according to a collaborative process.

  19. Z-buffer image assembly processing in high parallel visualization processing

    International Nuclear Information System (INIS)

    Kaneko, Isamu; Muramatsu, Kazuhiro

    2000-03-01

    On the platform of the parallel computer with many processors, the domain decomposition method is used as a popular means of parallel processing. In these days when the simulation scale becomes much larger and takes a lot of time, the simultaneous visualization processing with the actual computation is much more needed, and especially in case of a real-time visualization, the domain decomposition technique is indispensable. In case of parallel rendering processing, the rendered results must be gathered to one processor to compose the integrated picture in the last stage. This integration is usually conducted by the method using Z-buffer values. This process, however, induces the crucial problems of much lower speed processing and local memory shortage in case of parallel processing exceeding more than several tens of processors. In this report, the two new solutions are proposed. The one is the adoption of a special operator (Reduce operator) in the parallelization process, and the other is a buffer compression by deleting the background informations. This report includes the performance results of these new techniques to investigate their effect with use of the parallel computer Paragon. (author)

  20. Explosive processes in nucleosynthesis

    International Nuclear Information System (INIS)

    Boyd, R.N.

    2002-01-01

    There are many explosive processes in nucleosynthesis: big bang nucleosynthesis, the rp-process, the γ-process, the ν-process, and the r-process. However, I will discuss just the rp-process and the r-process in detail, primarily because both seem to have been very active research areas of late, and because they have great potential for studies with radioactive nuclear beams. I will also discuss briefly the γ-process because of its inevitability in conjunction with the rp-process. (orig.)

  1. Processing Depth, Elaboration of Encoding, Memory Stores, and Expended Processing Capacity.

    Science.gov (United States)

    Eysenck, Michael W.; Eysenck, M. Christine

    1979-01-01

    The effects of several factors on expended processing capacity were measured. Expended processing capacity was greater when information was retrieved from secondary memory than from primary memory, when processing was of a deep, semantic nature than when it was shallow and physical, and when processing was more elaborate. (Author/GDC)

  2. Sewer Processes

    DEFF Research Database (Denmark)

    Hvitved-Jacobsen, Thorkild; Vollertsen, Jes; Nielsen, Asbjørn Haaning

    Since the first edition was published over a decade ago, advancements have been made in the design, operation, and maintenance of sewer systems, and new problems have emerged. For example, sewer processes are now integrated in computer models, and simultaneously, odor and corrosion problems caused...... by hydrogen sulfide and other volatile organic compounds, as well as other potential health issues, have caused environmental concerns to rise. Reflecting the most current developments, Sewer Processes: Microbial and Chemical Process Engineering of Sewer Networks, Second Edition, offers the reader updated...... and valuable information on the sewer as a chemical and biological reactor. It focuses on how to predict critical impacts and control adverse effects. It also provides an integrated description of sewer processes in modeling terms. This second edition is full of illustrative examples and figures, includes...

  3. AN OVERVIEW OF PHARMACEUTICAL PROCESS VALIDATION AND PROCESS CONTROL VARIABLES OF TABLETS MANUFACTURING PROCESSES IN INDUSTRY

    OpenAIRE

    Mahesh B. Wazade*, Sheelpriya R. Walde and Abhay M. Ittadwar

    2012-01-01

    Validation is an integral part of quality assurance; the product quality is derived from careful attention to a number of factors including selection of quality parts and materials, adequate product and manufacturing process design, control of the process variables, in-process and end-product testing. Recently validation has become one of the pharmaceutical industry’s most recognized and discussed subjects. It is a critical success factor in product approval and ongoing commercialization, fac...

  4. Phenomena based Methodology for Process Synthesis incorporating Process Intensification

    DEFF Research Database (Denmark)

    Lutze, Philip; Babi, Deenesh Kavi; Woodley, John

    2013-01-01

    at processes at the lowest level of aggregation which is the phenomena level. In this paper, a phenomena based synthesis/design methodology incorporating process intensification is presented. Using this methodology, a systematic identification of necessary and desirable (integrated) phenomena as well......Process intensification (PI) has the potential to improve existing as well as conceptual processes, in order to achieve a more sustainable production. PI can be achieved at different levels. That is, the unit operations, functional and/or phenomena level. The highest impact is expected by looking...... as generation and screening of phenomena based flowsheet options are presented using a decomposition based solution approach. The developed methodology as well as necessary tools and supporting methods are highlighted through a case study involving the production of isopropyl-acetate....

  5. Minimal and careful processing

    OpenAIRE

    Nielsen, Thorkild

    2004-01-01

    In several standards, guidelines and publications, organic food processing is strongly associated with "minimal processing" and "careful processing". The term "minimal processing" is nowadays often used in the general food processing industry and described in literature. The term "careful processing" is used more specifically within organic food processing but is not yet clearly defined. The concept of carefulness seems to fit very well with the processing of organic foods, especially if it i...

  6. The Newest Laser Processing

    International Nuclear Information System (INIS)

    Lee, Baek Yeon

    2007-01-01

    This book mentions laser processing with laser principle, laser history, laser beam property, laser kinds, foundation of laser processing such as laser oscillation, characteristic of laser processing, laser for processing and its characteristic, processing of laser hole including conception of processing of laser hole and each material, and hole processing of metal material, cut of laser, reality of cut, laser welding, laser surface hardening, application case of special processing and safety measurement of laser.

  7. Process Integration Analysis of an Industrial Hydrogen Production Process

    OpenAIRE

    Stolten, Detlef; Grube, Thomas; Tock, Laurence; Maréchal, François; Metzger, Christian; Arpentinier, Philippe

    2010-01-01

    The energy efficiency of an industrial hydrogen production process using steam methane reforming (SMR) combined with the water gas shift reaction (WGS) is analyzed using process integration techniques based on heat cascade calculation and pinch analysis with the aim of identifying potential measures to enhance the process performance. The challenge is to satisfy the high temperature heat demand of the SMR reaction by minimizing the consumption of natural gas to feed the combustion and to expl...

  8. Developing engineering processes through integrated modelling of product and process

    DEFF Research Database (Denmark)

    Nielsen, Jeppe Bjerrum; Hvam, Lars

    2012-01-01

    This article aims at developing an operational tool for integrated modelling of product assortments and engineering processes in companies making customer specific products. Integrating a product model in the design of engineering processes will provide a deeper understanding of the engineering...... activities as well as insight into how product features affect the engineering processes. The article suggests possible ways of integrating models of products with models of engineering processes. The models have been tested and further developed in an action research study carried out in collaboration...... with a major international engineering company....

  9. Process-based costing.

    Science.gov (United States)

    Lee, Robert H; Bott, Marjorie J; Forbes, Sarah; Redford, Linda; Swagerty, Daniel L; Taunton, Roma Lee

    2003-01-01

    Understanding how quality improvement affects costs is important. Unfortunately, low-cost, reliable ways of measuring direct costs are scarce. This article builds on the principles of process improvement to develop a costing strategy that meets both criteria. Process-based costing has 4 steps: developing a flowchart, estimating resource use, valuing resources, and calculating direct costs. To illustrate the technique, this article uses it to cost the care planning process in 3 long-term care facilities. We conclude that process-based costing is easy to implement; generates reliable, valid data; and allows nursing managers to assess the costs of new or modified processes.

  10. Colloid process engineering

    CERN Document Server

    Peukert, Wolfgang; Rehage, Heinz; Schuchmann, Heike

    2015-01-01

    This book deals with colloidal systems in technical processes and the influence of colloidal systems by technical processes. It explores how new measurement capabilities can offer the potential for a dynamic development of scientific and engineering, and examines the origin of colloidal systems and its use for new products. The future challenges to colloidal process engineering are the development of appropriate equipment and processes for the production and obtainment of multi-phase structures and energetic interactions in market-relevant quantities. The book explores the relevant processes and for controlled production and how they can be used across all scales.

  11. Laser Processing of Multilayered Thermal Spray Coatings: Optimal Processing Parameters

    Science.gov (United States)

    Tewolde, Mahder; Zhang, Tao; Lee, Hwasoo; Sampath, Sanjay; Hwang, David; Longtin, Jon

    2017-12-01

    Laser processing offers an innovative approach for the fabrication and transformation of a wide range of materials. As a rapid, non-contact, and precision material removal technology, lasers are natural tools to process thermal spray coatings. Recently, a thermoelectric generator (TEG) was fabricated using thermal spray and laser processing. The TEG device represents a multilayer, multimaterial functional thermal spray structure, with laser processing serving an essential role in its fabrication. Several unique challenges are presented when processing such multilayer coatings, and the focus of this work is on the selection of laser processing parameters for optimal feature quality and device performance. A parametric study is carried out using three short-pulse lasers, where laser power, repetition rate and processing speed are varied to determine the laser parameters that result in high-quality features. The resulting laser patterns are characterized using optical and scanning electron microscopy, energy-dispersive x-ray spectroscopy, and electrical isolation tests between patterned regions. The underlying laser interaction and material removal mechanisms that affect the feature quality are discussed. Feature quality was found to improve both by using a multiscanning approach and an optional assist gas of air or nitrogen. Electrically isolated regions were also patterned in a cylindrical test specimen.

  12. Application of statistical process control and process capability analysis procedures in orbiter processing activities at the Kennedy Space Center

    Science.gov (United States)

    Safford, Robert R.; Jackson, Andrew E.; Swart, William W.; Barth, Timothy S.

    1994-01-01

    Successful ground processing at KSC requires that flight hardware and ground support equipment conform to specifications at tens of thousands of checkpoints. Knowledge of conformance is an essential requirement for launch. That knowledge of conformance at every requisite point does not, however, enable identification of past problems with equipment, or potential problem areas. This paper describes how the introduction of Statistical Process Control and Process Capability Analysis identification procedures into existing shuttle processing procedures can enable identification of potential problem areas and candidates for improvements to increase processing performance measures. Results of a case study describing application of the analysis procedures to Thermal Protection System processing are used to illustrate the benefits of the approaches described in the paper.

  13. Westinghouse modular grinding process - improvement for follow on processes

    Energy Technology Data Exchange (ETDEWEB)

    Fehrmann, Henning [Westinghouse Germany GmbH, Mannheim, State (Germany)

    2013-07-01

    In nuclear power plants (NPP) ion exchange (IX) resins are used in several systems for water treatment. The resins can be in bead or powdered form. For waste treatment of spent IX resins, two methods are basically used: Direct immobilization (e.g. with cement, bitumen, polymer or High Integrity Container (HIC)); Thermal treatment (e.g. drying, oxidation or pyrolysis). Bead resins have some properties (e.g. particle size and density) that can have negative impacts on following waste treatment processes. Negative impacts could be: Floatation of bead resins in cementation process; Sedimentation in pipeline during transportation; Poor compaction properties for Hot Resin Supercompaction (HRSC). Reducing the particle size of the bead resins can have beneficial effects enhancing further treatment processes and overcoming prior mentioned effects. Westinghouse Electric Company has developed a modular grinding process to crush/grind the bead resins. This modular process is designed for flexible use and enables a selective adjustment of particle size to tailor the grinding system to the customer needs. The system can be equipped with a crusher integrated in the process tank and if necessary a colloid mill. The crusher reduces the bead resins particle size and converts the bead resins to a pump able suspension with lower sedimentation properties. With the colloid mill the resins can be ground to a powder. Compared to existing grinding systems this equipment is designed to minimize radiation exposure of the worker during operation and maintenance. Using the crushed and/or ground bead resins has several beneficial effects like facilitating cementation process and recipe development, enhancing oxidation of resins, improving the Hot Resin Supercompaction volume reduction performance. (authors)

  14. Westinghouse modular grinding process - improvement for follow on processes

    International Nuclear Information System (INIS)

    Fehrmann, Henning

    2013-01-01

    In nuclear power plants (NPP) ion exchange (IX) resins are used in several systems for water treatment. The resins can be in bead or powdered form. For waste treatment of spent IX resins, two methods are basically used: Direct immobilization (e.g. with cement, bitumen, polymer or High Integrity Container (HIC)); Thermal treatment (e.g. drying, oxidation or pyrolysis). Bead resins have some properties (e.g. particle size and density) that can have negative impacts on following waste treatment processes. Negative impacts could be: Floatation of bead resins in cementation process; Sedimentation in pipeline during transportation; Poor compaction properties for Hot Resin Supercompaction (HRSC). Reducing the particle size of the bead resins can have beneficial effects enhancing further treatment processes and overcoming prior mentioned effects. Westinghouse Electric Company has developed a modular grinding process to crush/grind the bead resins. This modular process is designed for flexible use and enables a selective adjustment of particle size to tailor the grinding system to the customer needs. The system can be equipped with a crusher integrated in the process tank and if necessary a colloid mill. The crusher reduces the bead resins particle size and converts the bead resins to a pump able suspension with lower sedimentation properties. With the colloid mill the resins can be ground to a powder. Compared to existing grinding systems this equipment is designed to minimize radiation exposure of the worker during operation and maintenance. Using the crushed and/or ground bead resins has several beneficial effects like facilitating cementation process and recipe development, enhancing oxidation of resins, improving the Hot Resin Supercompaction volume reduction performance. (authors)

  15. Defense waste processing facility precipitate hydrolysis process

    International Nuclear Information System (INIS)

    Doherty, J.P.; Eibling, R.E.; Marek, J.C.

    1986-03-01

    Sodium tetraphenylborate and sodium titanate are used to assist in the concentration of soluble radionuclide in the Savannah River Plant's high-level waste. In the Defense Waste Processing Facility, concentrated tetraphenylborate/sodium titanate slurry containing cesium-137, strontium-90 and traces of plutonium from the waste tank farm is hydrolyzed in the Salt Processing Cell forming organic and aqueous phases. The two phases are then separated and the organic phase is decontaminated for incineration outside the DWPF building. The aqueous phase, containing the radionuclides and less than 10% of the original organic, is blended with the insoluble radionuclides in the high-level waste sludge and is fed to the glass melter for vitrification into borosilicate glass. During the Savannah River Laboratory's development of this process, copper (II) was found to act as a catalyst during the hydrolysis reactions, which improved the organic removal and simplified the design of the reactor

  16. On some applications of diffusion processes for image processing

    International Nuclear Information System (INIS)

    Morfu, S.

    2009-01-01

    We propose a new algorithm inspired by the properties of diffusion processes for image filtering. We show that purely nonlinear diffusion processes ruled by Fisher equation allows contrast enhancement and noise filtering, but involves a blurry image. By contrast, anisotropic diffusion, described by Perona and Malik algorithm, allows noise filtering and preserves the edges. We show that combining the properties of anisotropic diffusion with those of nonlinear diffusion provides a better processing tool which enables noise filtering, contrast enhancement and edge preserving.

  17. Grind hardening process

    CERN Document Server

    Salonitis, Konstantinos

    2015-01-01

    This book presents the grind-hardening process and the main studies published since it was introduced in 1990s.  The modelling of the various aspects of the process, such as the process forces, temperature profile developed, hardness profiles, residual stresses etc. are described in detail. The book is of interest to the research community working with mathematical modeling and optimization of manufacturing processes.

  18. Transuranium processing plant

    International Nuclear Information System (INIS)

    King, L.J.

    1983-01-01

    The Transuranium Processing Plant (TRU) is a remotely operated, hot-cell, chemical processing facility of advanced design. The heart of TRU is a battery of nine heavily shielded process cells housed in a two-story building. Each cell, with its 54-inch-thick walls of a special high-density concrete, has enough shielding to stop the neutrons and gamma radiation from 1 gram of 252/sub Cf/ and associated fission products. Four cells contain chemical processing equipment, three contain equipment for the preparation and inspection of HFIR targets, and two cells are used for analytical chemistry operations. In addition, there are eight laboratories used for process development, for part of the process-control analyses, and for product finishing operations. Although the Transuranium Processing Plant was built for the purpose of recovering transuranium elements from targets irradiated in the High Flux Isotope Reactor (HFIR), it is also a highly versatile facility which has extensive provisions for changing and modifying equipment. Thus, it was a relatively simple matter to install a Solvent Extraction Test Facility (SETF) in one of the TRU chemical processing cells for use in the evaluation and demonstration of solvent extraction flowsheets for the recovery of fissile and fertile materials from irradiated reactor fuels. The equipment in the SETF has been designed for process development and demonstrations and the particular type of mixer-settler contactors was chosen because it is easy to observe and sample

  19. Welding processes handbook

    CERN Document Server

    Weman, Klas

    2003-01-01

    Deals with the main commercially significant and commonly used welding processes. This title takes the student or novice welder through the individual steps involved in each process in an easily understood way. It covers many of the requirements referred to in European Standards including EN719, EN 729, EN 729 and EN 287.$bWelding processes handbook is a concise, explanatory guide to the main commercially significant and commonly-used welding processes. It takes the novice welder or student through the individual steps involved in each process in a clear and easily understood way. It is intended to provide an up-to-date reference to the major applications of welding as they are used in industry. The contents have been arranged so that it can be used as a textbook for European welding courses in accordance with guidelines from the European Welding Federation. Welding processes and equipment necessary for each process are described so that they can be applied to all instruction levels required by the EWF and th...

  20. Kidney transplantation process in Brazil represented in business process modeling notation.

    Science.gov (United States)

    Peres Penteado, A; Molina Cohrs, F; Diniz Hummel, A; Erbs, J; Maciel, R F; Feijó Ortolani, C L; de Aguiar Roza, B; Torres Pisa, I

    2015-05-01

    Kidney transplantation is considered to be the best treatment for people with chronic kidney failure, because it improves the patients' quality of life and increases their length of survival compared with patients undergoing dialysis. The kidney transplantation process in Brazil is defined through laws, decrees, ordinances, and resolutions, but there is no visual representation of this process. The aim of this study was to analyze official documents to construct a representation of the kidney transplantation process in Brazil with the use of business process modeling notation (BPMN). The methodology for this study was based on an exploratory observational study, document analysis, and construction of process diagrams with the use of BPMN. Two rounds of validations by specialists were conducted. The result includes the kidney transplantation process in Brazil representation with the use of BPMN. We analyzed 2 digital documents that resulted in 2 processes with 45 total of activities and events, 6 organizations involved, and 6 different stages of the process. The constructed representation makes it easier to understand the rules for the business of kidney transplantation and can be used by the health care professionals involved in the various activities within this process. Construction of a representation with language appropriate for the Brazilian lay public is underway. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. High temperature nuclear process heat systems for chemical processes

    International Nuclear Information System (INIS)

    Jiacoletti, R.J.

    1976-01-01

    The development planning and status of the very high temperature gas cooled reactor as a source of industrial process heat is presented. The dwindling domestic reserves of petroleum and natural gas dictate major increases in the utilization of coal and nuclear sources to meet the national energy demand. The nuclear process heat system offers a unique combination of the two that is environmentally and economically attractive and technically sound. Conceptual studies of several energy-intensive processes coupled to a nuclear heat source are presented

  2. Process development

    International Nuclear Information System (INIS)

    Zapata G, G.

    1989-01-01

    Process development: The paper describes the organization and laboratory facilities of the group working on radioactive ore processing studies. Contains a review of the carried research and the plans for the next future. A list of the published reports is also presented

  3. Information Technology Process Improvement Decision-Making: An Exploratory Study from the Perspective of Process Owners and Process Managers

    Science.gov (United States)

    Lamp, Sandra A.

    2012-01-01

    There is information available in the literature that discusses information technology (IT) governance and investment decision making from an executive-level perception, yet there is little information available that offers the perspective of process owners and process managers pertaining to their role in IT process improvement and investment…

  4. Process synthesis, design and analysis using a process-group contribution method

    DEFF Research Database (Denmark)

    Kumar Tula, Anjan; Eden, Mario R.; Gani, Rafiqul

    2015-01-01

    ) techniques. The fundamental pillars of this framework are the definition and use of functional process-groups (building blocks) representing a wide range of process operations, flowsheet connectivity rules to join the process-groups to generate all the feasible flowsheet alternatives and flowsheet property...... models like energy consumption, atom efficiency, environmental impact to evaluate the performance of the generated alternatives. In this way, a list of feasible flowsheets are quickly generated, screened and selected for further analysis. Since the flowsheet is synthesized and the operations......This paper describes the development and application of a process-group contribution method to model, simulate and synthesize chemical processes. Process flowsheets are generated in the same way as atoms or groups of atoms are combined to form molecules in computer aided molecular design (CAMD...

  5. Development of interface technology between unit processes in E-Refining process

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S. H.; Lee, H. S.; Kim, J. G. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    The pyroprocessing is composed mainly four subprocesses, such as an electrolytic reduction, an electrorefining, an electrowinning, and waste salt regeneration/ solidification processes. The electrorefining process, one of main processes which are composed of pyroprocess to recover the useful elements from spent fuel, is under development by Korea Atomic Energy Research Institute as a sub process of pyrochemical treatment of spent PWR fuel. The CERS(Continuous ElectroRefining System) is composed of some unit processes such as an electrorefiner, a salt distiller, a melting furnace for the U-ingot and U-chlorinator (UCl{sub 3} making equipment) as shown in Fig. 1. In this study, the interfaces technology between unit processes in E-Refining system is investigated and developed for the establishment of integrated E-Refining operation system as a part of integrated pyroprocessing

  6. A secondary fuel removal process: plasma processing

    Energy Technology Data Exchange (ETDEWEB)

    Min, J Y; Kim, Y S [Hanyang Univ., Seoul (Korea, Republic of); Bae, K K; Yang, M S [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-07-01

    Plasma etching process of UO{sub 2} by using fluorine containing gas plasma is studied as a secondary fuel removal process for DUPIC (Direct Use of PWR spent fuel Into Candu) process which is taken into consideration for potential future fuel cycle in Korea. CF{sub 4}/O{sub 2} gas mixture is chosen for reactant gas and the etching rates of UO{sub 2} by the gas plasma are investigated as functions of CF{sub 4}/O{sub 2} ratio, plasma power, substrate temperature, and plasma gas pressure. It is found that the optimum CF{sub 4}/O{sub 2} ratio is around 4:1 at all temperatures up to 400 deg C and the etching rate increases with increasing r.f. power and substrate temperature. Under 150W r.f. power the etching rate reaches 1100 monolayers/min at 400 deg C, which is equivalent to about 0.5mm/min. (author).

  7. Clinical Process Intelligence

    DEFF Research Database (Denmark)

    Vilstrup Pedersen, Klaus

    2006-01-01

    .e. local guidelines. From a knowledge management point of view, this externalization of generalized processes, gives the opportunity to learn from, evaluate and optimize the processes. "Clinical Process Intelligence" (CPI), will denote the goal of getting generalized insight into patient centered health...

  8. Sustainable processing

    DEFF Research Database (Denmark)

    Kristensen, Niels Heine

    2004-01-01

    Kristensen_NH and_Beck A: Sustainable processing. In Otto Schmid, Alexander Beck and Ursula Kretzschmar (Editors) (2004): Underlying Principles in Organic and "Low-Input Food" Processing - Literature Survey. Research Institute of Organic Agriculture FiBL, CH-5070 Frick, Switzerland. ISBN 3-906081-58-3...

  9. Food processing

    NARCIS (Netherlands)

    Teodorowicz, Malgorzata; Neerven, Van Joost; Savelkoul, Huub

    2017-01-01

    The majority of foods that are consumed in our developed society have been processed. Processing promotes a non-enzymatic reaction between proteins and sugars, the Maillard reaction (MR). Maillard reaction products (MRPs) contribute to the taste, smell and color of many food products, and thus

  10. Using Process Mining to Learn from Process Changes in Evolutionary Systems

    NARCIS (Netherlands)

    Günther, Christian W.; Rinderle, S.B.; Reichert, M.U.; van der Aalst, Wil M.P.; Recker, Jan

    2008-01-01

    Traditional information systems struggle with the requirement to provide flexibility and process support while still enforcing some degree of control. Accordingly, adaptive process management systems (PMSs) have emerged that provide some flexibility by enabling dynamic process changes during

  11. REALIZING BUSINESS PROCESS MANAGEMENT BY HELP OF A PROCESS MAPPING DATABASE TOOL

    CERN Document Server

    Vergili, Ceren

    2016-01-01

    In a typical business sector, processes are the building blocks of the achievement. A considerable percentage of the processes are consisting of business processes. This fact is bringing the fact that business sectors are in need of a management discipline. Business Process Management (BPM) is a discipline that combines modelling, automation, execution, control, measurement, and optimization of process by considering enterprise goals, spanning systems, employees, customers, and partners. CERN’s EN – HE – HM section desires to apply the BPM discipline appropriately for improving their necessary technical, administrative and managerial actions to supply appropriate CERN industrial transport, handling and lifting equipment and to maintain it. For this reason, a Process Mapping Database Tool is created to develop a common understanding about how the section members can visualize their processes, agree on quality standards and on how to improve. It provides a management support by establishing Process Charts...

  12. Multimodal Processes Rescheduling

    DEFF Research Database (Denmark)

    Bocewicz, Grzegorz; Banaszak, Zbigniew A.; Nielsen, Peter

    2013-01-01

    Cyclic scheduling problems concerning multimodal processes are usually observed in FMSs producing multi-type parts where the Automated Guided Vehicles System (AGVS) plays a role of a material handling system. Schedulability analysis of concurrently flowing cyclic processes (SCCP) exe-cuted in the......Cyclic scheduling problems concerning multimodal processes are usually observed in FMSs producing multi-type parts where the Automated Guided Vehicles System (AGVS) plays a role of a material handling system. Schedulability analysis of concurrently flowing cyclic processes (SCCP) exe...

  13. Process-aware information systems : lessons to be learned from process mining

    NARCIS (Netherlands)

    Aalst, van der W.M.P.; Jensen, K.; Aalst, van der W.M.P.

    2009-01-01

    A Process-Aware Information System (PAIS) is a software system that manages and executes operational processes involving people, applications, and/or information sources on the basis of process models. Example PAISs are workflow management systems, case-handling systems, enterprise information

  14. Applicability of product-driven process synthesis to separation processes in food

    NARCIS (Netherlands)

    Jankowiak, L.; Goot, van der A.J.; Trifunovic, O.; Bongers, P.; Boom, R.M.

    2012-01-01

    The demand for more sustainable processing in the food industry is rising but requires structured methodologies to support the fast implementation of new economic and sustainable processes. Product-driven process synthesis (PDPS) is a recently established methodology facilitating the rapid

  15. Synroc processing options

    International Nuclear Information System (INIS)

    Rozsa, R.B.; Hoenig, C.L.

    1981-01-01

    Synroc is a titanate-based ceramic material currently being developed for immobilizing high-level nuclear reactor wastes in solid form. Synroc D is a unique variation of Synroc. It can contain the high-level defense wastes, particularly those in storage at the Savannah River Plant. In this report, we review the early development of the initial Synroc process, discuss modification and other options that simplify it overall, and recommend the future direction of research and development in the processing area. A reference Synroc process is described briefly and contrasted with the Savannah River Laboratory glass-based reference case. Preliminary engineering layouts show Synroc to be a more complex processing operation and, thus, more expensive than the glass-based process. However, we believe that simplifications, which will significantly reduce the cost difference, are possible. Further research and development will continue in the areas of slurry processing, fluidized bed calcination, and mineralization. This last will use sintering, hot uniaxial pressing, or hot isostatic pressing

  16. Design Processes

    DEFF Research Database (Denmark)

    Ovesen, Nis

    2009-01-01

    Inspiration for most research and optimisations on design processes still seem to focus within the narrow field of the traditional design practise. The focus in this study turns to associated businesses of the design professions in order to learn from their development processes. Through interviews...... and emerging production methods....

  17. Process modeling style

    CERN Document Server

    Long, John

    2014-01-01

    Process Modeling Style focuses on other aspects of process modeling beyond notation that are very important to practitioners. Many people who model processes focus on the specific notation used to create their drawings. While that is important, there are many other aspects to modeling, such as naming, creating identifiers, descriptions, interfaces, patterns, and creating useful process documentation. Experience author John Long focuses on those non-notational aspects of modeling, which practitioners will find invaluable. Gives solid advice for creating roles, work produ

  18. Improving Healthcare Logistics Processes

    DEFF Research Database (Denmark)

    Feibert, Diana Cordes

    logistics processes in hospitals and aims to provide theoretically and empirically based evidence for improving these processes to both expand the knowledge base of healthcare logistics and provide a decision tool for hospital logistics managers to improve their processes. Case studies were conducted...... processes. Furthermore, a method for benchmarking healthcare logistics processes was developed. Finally, a theoretically and empirically founded framework was developed to support managers in making an informed decision on how to improve healthcare logistics processes. This study contributes to the limited...... literature concerned with the improvement of logistics processes in hospitals. Furthermore, the developed framework provides guidance for logistics managers in hospitals on how to improve their processes given the circumstances in which they operate....

  19. Nuclear process heat

    International Nuclear Information System (INIS)

    Barnert, H.; Hohn, H.; Schad, M.; Schwarz, D.; Singh, J.

    1993-01-01

    In a system for the application of high temperature heat from the HTR one must distinguish between the current generation and the use of process heat. In this respect it is important that the current can be generated by dual purpose power plants. The process heat is used as sensible heat, vaporisation heat and as chemical energy at the chemical conversion for the conversion of raw materials, the refinement of fossil primary energy carriers and finally circuit processes for the fission of water. These processes supply the market for heat, fuels, motor fuels and basic materials. Fifteen examples of HTR heat processes from various projects and programmes are presented in form of energy balances, however in a rather short way. (orig./DG) [de

  20. Business process support

    Energy Technology Data Exchange (ETDEWEB)

    Carle, Adriana; Fiducia, Daniel [Transportadora de Gas del Sur S.A. (TGS), Buenos Aires (Argentina)

    2005-07-01

    This paper is about the own development of business support software. The developed applications are used to support two business processes: one of them is the process of gas transportation and the other is the natural gas processing. This software has interphases with the ERP SAP, software SCADA and on line gas transportation simulation software. The main functionalities of the applications are: entrance on line real time of clients transport nominations, transport programming, allocation of the clients transport nominations, transport control, measurements, balanced pipeline, allocation of gas volume to the gas processing plants, calculate of product tons processed in each plant and tons of product distributed to clients. All the developed software generates information to the internal staff, regulatory authorities and clients. (author)

  1. Process for making unsaturated hydrocarbons using microchannel process technology

    Science.gov (United States)

    Tonkovich, Anna Lee [Dublin, OH; Yuschak, Thomas [Lewis Center, OH; LaPlante, Timothy J [Columbus, OH; Rankin, Scott [Columbus, OH; Perry, Steven T [Galloway, OH; Fitzgerald, Sean Patrick [Columbus, OH; Simmons, Wayne W [Dublin, OH; Mazanec, Terry Daymo, Eric

    2011-04-12

    The disclosed invention relates to a process for converting a feed composition comprising one or more hydrocarbons to a product comprising one or more unsaturated hydrocarbons, the process comprising: flowing the feed composition and steam in contact with each other in a microchannel reactor at a temperature in the range from about 200.degree. C. to about 1200.degree. C. to convert the feed composition to the product, the process being characterized by the absence of catalyst for converting the one or more hydrocarbons to one or more unsaturated hydrocarbons. Hydrogen and/or oxygen may be combined with the feed composition and steam.

  2. Correlation between radwaste processing and hazardous waste treatment processes

    International Nuclear Information System (INIS)

    Block, O.U.J.; Tulipano, F.J.

    1988-01-01

    The basic framework under SARA has established that preferred remedies are those which permanently and significantly reduce toxicity, mobility or volume of wastes. In the 1970's radwaste process designs at power plants received pressure to satisfy essentially the same criteria when increased emphasis was placed on limited disposal sites which resulted in rapidly escalating disposal costs. This paper provides a historical perspective of radwaste experience and discusses valuable insight to hazardous waste treatment technologies. The radwaste system experience is discussed in terms of providing a source of proven and reliable technologies. Discussion is presented on specific radwaste processes which are applicable technologies for hazardous waste treatment. The technologies presented include (a) Solidification, (b) Evaporation, and (c) Incineration. Experience is presented which establishes assurance that the treatment technologies will provide a permanent remedy to hazardous waste treatment. This paper describes typical radwaste solidification, evaporation and incineration processes at power plants. The design requirements and implementation of radwaste equipment is correlated to design requirement of hazardous waste equipment. Specific discussion is provided on how the available process equipment can reduce toxicity, mobility, and volume of waste. Discussion is presented on how the standard off the shelf processing equipment needs to be modified for radwaste and hazardous waste applications

  3. Modeling Aspects of Activated Sludge Processes Part l l: Mathematical Process Modeling and Biokinetics of Activated Sludge Processes

    Energy Technology Data Exchange (ETDEWEB)

    AbdElHaleem, H S [Cairo Univ.-CivlI Eng. Dept., Giza (Egypt); EI-Ahwany, A H [CairoUlmrsity- Faculty ofEngincering - Chemical Engineering Department, Giza (Egypt); Ibrahim, H I [Helwan University- Faculty of Engineering - Biomedical Engineering Department, Helwan (Egypt); Ibrahim, G [Menofia University- Faculty of Engineering Sbebin EI Kom- Basic Eng. Sc. Dept., Menofia (Egypt)

    2004-07-01

    Mathematical process modeling and biokinetics of activated sludge process were reviewed considering different types of models. It has been evaluated the task group models of ASMI. and 2, and 3 versioned by Henze et al considering the conditions of each model and the different processes of which every model consists. It is revealed that ASMI contains some defects avoided in ASM3. Relied on homogeneity, Models can be classified into homogenous models characterized by taking the activated sludge process as one phase. In this type of models, the internal mass transfer inside the floes was neglected.. Hence, the kinetic parameter produces can be considered inaccurate. The other type of models is the heterogeneous model This type considers the mass transfer operations in addition to the biochemical reaction processes; hence, the resulted kinetic parameters can be considered more accurate than that of homogenous type.

  4. Modeling Aspects of Activated Sludge Processes Part l l: Mathematical Process Modeling and Biokinetics of Activated Sludge Processes

    International Nuclear Information System (INIS)

    AbdElHaleem, H.S.; EI-Ahwany, A. H.; Ibrahim, H.I.; Ibrahim, G.

    2004-01-01

    Mathematical process modeling and biokinetics of activated sludge process were reviewed considering different types of models. It has been evaluated the task group models of ASMI. and 2, and 3 versioned by Henze et al considering the conditions of each model and the different processes of which every model consists. It is revealed that ASMI contains some defects avoided in ASM3. Relied on homogeneity, Models can be classified into homogenous models characterized by taking the activated sludge process as one phase. In this type of models, the internal mass transfer inside the floes was neglected.. Hence, the kinetic parameter produces can be considered inaccurate. The other type of models is the heterogeneous model This type considers the mass transfer operations in addition to the biochemical reaction processes; hence, the resulted kinetic parameters can be considered more accurate than that of homogenous type

  5. A Dual Process Approach to Understand Tourists’ Destination Choice Processes

    DEFF Research Database (Denmark)

    Kock, Florian; Josiassen, Alexander; Assaf, Albert

    2017-01-01

    Most studies that investigate tourists' choices of destinations apply the concept of mental destination representations, also referred to as destination image. The present study investigates tourists’ destination choice processes by conceptualizing how different components of destination image...... are mentally processed in tourists' minds. Specifically, the seminal dual processing approach is applied to the destination image literature. By doing this, we argue that some components of mental destination representations are processed systematically while others serve as inputs for heuristics...... that individuals apply to inform their decision making. Understanding how individuals make use of their mental destination representations and how they color their decision-making is essential in order to better explain tourist behavior....

  6. Ornstein-Uhlenbeck Processes Simulation

    OpenAIRE

    Kuzmina, A.

    2012-01-01

    In this paper we give a brief introduction to Ornstein-Uhlenbeck processes and their simulation methods. Ornstein-Uhlenbeck processes were introduced by Barndorff-Nielsen and Shephard (2001) as a model to describe volatility in finance. Ornstein-Uhlenbeck processes are based on Levy processes. Levy processes simulation may be found in [1, 2].

  7. Process heat. Triggering the processes

    Energy Technology Data Exchange (ETDEWEB)

    Augsten, Eva

    2012-07-01

    If solar process heat is to find a market, then the decision makers in industrial companies need to be aware that it actually exists. This was one of the main goals of the So-Pro project, which officially drew to a close in April 2012. (orig.)

  8. Optimality of Poisson Processes Intensity Learning with Gaussian Processes

    NARCIS (Netherlands)

    Kirichenko, A.; van Zanten, H.

    2015-01-01

    In this paper we provide theoretical support for the so-called "Sigmoidal Gaussian Cox Process" approach to learning the intensity of an inhomogeneous Poisson process on a d-dimensional domain. This method was proposed by Adams, Murray and MacKay (ICML, 2009), who developed a tractable computational

  9. Is There Dependence Between Process Maturity and Process Performance?

    NARCIS (Netherlands)

    Joost Spekschoor; Pascal Ravesteijn; Roeland Loggen; dr. Martijn Zoet

    2012-01-01

    During recent years the world has seen rapid changes such as globalization, the Internet, and the rise of new economies. To survive these changes organizations need to be in control of their processes, and be able to continuously improve the process performance. Therefore many organizations are

  10. Stream-processing pipelines: processing of streams on multiprocessor architecture

    NARCIS (Netherlands)

    Kavaldjiev, N.K.; Smit, Gerardus Johannes Maria; Jansen, P.G.

    In this paper we study the timing aspects of the operation of stream-processing applications that run on a multiprocessor architecture. Dependencies are derived for the processing and communication times of the processors in such a system. Three cases of real-time constrained operation and four

  11. Detecting Difference between Process Models Based on the Refined Process Structure Tree

    Directory of Open Access Journals (Sweden)

    Jing Fan

    2017-01-01

    Full Text Available The development of mobile workflow management systems (mWfMS leads to large number of business process models. In the meantime, the location restriction embedded in mWfMS may result in different process models for a single business process. In order to help users quickly locate the difference and rebuild the process model, detecting the difference between different process models is needed. Existing detection methods either provide a dissimilarity value to represent the difference or use predefined difference template to generate the result, which cannot reflect the entire composition of the difference. Hence, in this paper, we present a new approach to solve this problem. Firstly, we parse the process models to their corresponding refined process structure trees (PSTs, that is, decomposing a process model into a hierarchy of subprocess models. Then we design a method to convert the PST to its corresponding task based process structure tree (TPST. As a consequence, the problem of detecting difference between two process models is transformed to detect difference between their corresponding TPSTs. Finally, we obtain the difference between two TPSTs based on the divide and conquer strategy, where the difference is described by an edit script and we make the cost of the edit script close to minimum. The extensive experimental evaluation shows that our method can meet the real requirements in terms of precision and efficiency.

  12. Preliminary evaluation of alternative waste form solidification processes. Volume I. Identification of the processes

    International Nuclear Information System (INIS)

    Treat, R.L.; Nesbitt, J.F.; Blair, H.T.; Carter, J.G.; Gorton, P.S.; Partain, W.L.; Timmerman, C.L.

    1980-04-01

    This document contains preconceptual design data on 11 processes for the solidification and isolation of nuclear high-level liquid wastes (HLLW). The processes are: in-can glass melting (ICGM) process, joule-heated glass melting (JHGM) process, glass-ceramic (GC) process, marbles-in-lead (MIL) matrix process, supercalcine pellets-in-metal (SCPIM) matrix process, pyrolytic-carbon coated pellets-in-metal (PCCPIM) matrix process, supercalcine hot-isostatic-pressing (SCHIP) process, SYNROC hot-isostatic-pressing (SYNROC HIP) process, titanate process, concrete process, and cermet process. For the purposes of this study, it was assumed that each of the solidification processes is capable of handling similar amounts of HLLW generated in a production-sized fuel reprocessing plant. It was also assumed that each of the processes would be enclosed in a shielded canyon or cells within a waste facility located at the fuel reprocessing plant. Finally, it was assumed that all of the processes would be subject to the same set of regulations, codes and standards. Each of the solidification processes converts waste into forms that may be acceptable for geological disposal. Each process begins with the receipt of HLLW from the fuel reprocessing plant. In this study, it was assumed that the original composition of the HLLW would be the same for each process. The process ends when the different waste forms are enclosed in canisters or containers that are acceptable for interim storage. Overviews of each of the 11 processes and the bases used for their identification are presented in the first part of this report. Each process, including its equipment and its requirements, is covered in more detail in Appendices A through K. Pertinent information on the current state of the art and the research and development required for the implementation of each process are also noted in the appendices

  13. Suppurative processes

    International Nuclear Information System (INIS)

    Vinner, M.G.

    1983-01-01

    Suppurative process in the case of bronchiectatic disease, abscess and gang rene of lungs, has been described. Characteristic signs of roentgenologic pictu re of the above-mentioned diseases are considered. It is shown,that in most cas es roentgenologic studies give a possibility to make a high-quality diagnosis of suppurative processes

  14. Investigating the Process of Process Modeling with Eye Movement Analysis

    OpenAIRE

    Pinggera, Jakob; Furtner, Marco; Martini, Markus; Sachse, Pierre; Reiter, Katharina; Zugal, Stefan; Weber, Barbara

    2015-01-01

    Research on quality issues of business process models has recently begun to explore the process of creating process models by analyzing the modeler's interactions with the modeling environment. In this paper we aim to complement previous insights on the modeler's modeling behavior with data gathered by tracking the modeler's eye movements when engaged in the act of modeling. We present preliminary results and outline directions for future research to triangulate toward a more comprehensive un...

  15. Radiotracer investigations of the flotation process in copper ore processing

    International Nuclear Information System (INIS)

    Petryka, L.; Przewlocki, K.

    1983-01-01

    Optimization of copper ore processing requires in particular the investigation of the flotation process. 64 Cu induced in natural ore by activation was used as a tracer. Detailed measurements were performed in an industrial flotation plant consisting of 14 cells. As a result the mean residence time of different grain size fractions of natural copper sulphide was determined for all parts of the flotation plant together with the efficiency of the flotation process. (author)

  16. Shot-noise-weighted processes : a new family of spatial point processes

    NARCIS (Netherlands)

    M.N.M. van Lieshout (Marie-Colette); I.S. Molchanov (Ilya)

    1995-01-01

    textabstractThe paper suggests a new family of of spatial point processes distributions. They are defined by means of densities with respect to the Poisson point process within a bounded set. These densities are given in terms of a functional of the shot-noise process with a given influence

  17. Process Management Plans

    Directory of Open Access Journals (Sweden)

    Tomasz Miksa

    2014-07-01

    Full Text Available In the era of research infrastructures and big data, sophisticated data management practices are becoming essential building blocks of successful science. Most practices follow a data-centric approach, which does not take into account the processes that created, analysed and presented the data. This fact limits the possibilities for reliable verification of results. Furthermore, it does not guarantee the reuse of research, which is one of the key aspects of credible data-driven science. For that reason, we propose the introduction of the new concept of Process Management Plans, which focus on the identification, description, sharing and preservation of the entire scientific processes. They enable verification and later reuse of result data and processes of scientific experiments. In this paper we describe the structure and explain the novelty of Process Management Plans by showing in what way they complement existing Data Management Plans. We also highlight key differences, major advantages, as well as references to tools and solutions that can facilitate the introduction of Process Management Plans.

  18. DECAB: process development of a phase change absorption process

    NARCIS (Netherlands)

    Sanchez Fernandez, E.; Goetheer, E.L.V.

    2011-01-01

    This work describes the conceptual design of a novel separation process for CO2 removal from flue gas based on precipitating solvents. The process here described (DECAB) is an enhanced CO2 absorption based on the Le Chatelier's principle, which states that reaction equilibrium can be shifted by

  19. The H-Oil process: a worldwide leader in vacuum residue hydro processing

    Energy Technology Data Exchange (ETDEWEB)

    Colyar, J.J.; Wisdom, L.I.; Koskas, A.

    1996-12-31

    The h-Oil process is a catalytic hydrocracking process which is used to convert and upgrade petroleum residua and heavy oils. This paper discusses additional background information on the H-Oil process, some of the key advances made to the process and applications for the Latin America market. 5 refs., 6 tabs.., 2 figs.

  20. Development of the Log-in Process and the Operation Process for the VHTR-SI Process Dynamic Simulation Code

    International Nuclear Information System (INIS)

    Chang, Jiwoon; Shin, Youngjoon; Kim, Jihwan; Lee, Kiyoung; Lee, Wonjae; Chang, Jonghwa; Youn, Cheung

    2009-01-01

    The VHTR-SI process is a hydrogen production technique by using Sulfur and Iodine. The SI process for a hydrogen production uses a high temperature (about 950 .deg. C) of the He gas which is a cooling material for an energy sources. The Korea Atomic Energy Research Institute Dynamic Simulation Code (KAERI DySCo) is an integration application software that simulates the dynamic behavior of the VHTR-SI process. A dynamic modeling is used to express and model the behavior of the software system over time. The dynamic modeling deals with the control flow of system, the interaction of objects and the order of actions in view of a time and transition by using a sequence diagram and a state transition diagram. In this paper, we present an user log-in process and an operation process for the KAERI DySCo by using a sequence diagram and a state transition diagram

  1. Quantifying Quantum-Mechanical Processes.

    Science.gov (United States)

    Hsieh, Jen-Hsiang; Chen, Shih-Hsuan; Li, Che-Ming

    2017-10-19

    The act of describing how a physical process changes a system is the basis for understanding observed phenomena. For quantum-mechanical processes in particular, the affect of processes on quantum states profoundly advances our knowledge of the natural world, from understanding counter-intuitive concepts to the development of wholly quantum-mechanical technology. Here, we show that quantum-mechanical processes can be quantified using a generic classical-process model through which any classical strategies of mimicry can be ruled out. We demonstrate the success of this formalism using fundamental processes postulated in quantum mechanics, the dynamics of open quantum systems, quantum-information processing, the fusion of entangled photon pairs, and the energy transfer in a photosynthetic pigment-protein complex. Since our framework does not depend on any specifics of the states being processed, it reveals a new class of correlations in the hierarchy between entanglement and Einstein-Podolsky-Rosen steering and paves the way for the elaboration of a generic method for quantifying physical processes.

  2. Hydrogen production processes

    International Nuclear Information System (INIS)

    2003-01-01

    The goals of this first Gedepeon workshop on hydrogen production processes are: to stimulate the information exchange about research programs and research advances in the domain of hydrogen production processes, to indicate the domains of interest of these processes and the potentialities linked with the coupling of a nuclear reactor, to establish the actions of common interest for the CEA, the CNRS, and eventually EDF, that can be funded in the framework of the Gedepeon research group. This document gathers the slides of the 17 presentations given at this workshop and dealing with: the H 2 question and the international research programs (Lucchese P.); the CEA's research program (Lucchese P., Anzieu P.); processes based on the iodine/sulfur cycle: efficiency of a facility - flow-sheets, efficiencies, hard points (Borgard J.M.), R and D about the I/S cycle: Bunsen reaction (Colette S.), R and D about the I/S cycle: the HI/I 2 /H 2 O system (Doizi D.), demonstration loop/chemical engineering (Duhamet J.), materials and corrosion (Terlain A.); other processes under study: the Westinghouse cycle (Eysseric C.), other processes under study at the CEA (UT3, plasma,...) (Lemort F.), database about thermochemical cycles (Abanades S.), Zn/ZnO cycle (Broust F.), H 2 production by cracking, high temperature reforming with carbon trapping (Flamant G.), membrane technology (De Lamare J.); high-temperature electrolysis: SOFC used as electrolyzers (Grastien R.); generic aspects linked with hydrogen production: technical-economical evaluation of processes (Werkoff F.), thermodynamic tools (Neveu P.), the reactor-process coupling (Aujollet P.). (J.S.)

  3. Materials, process, product analysis of coal process technology. Phase I final report

    Energy Technology Data Exchange (ETDEWEB)

    Saxton, J. C.; Roig, R. W.; Loridan, A.; Leggett, N. E.; Capell, R. G.; Humpstone, C. C.; Mudry, R. N.; Ayres, E.

    1976-02-01

    The purpose of materials-process-product analysis is a systematic evaluation of alternative manufacturing processes--in this case processes for converting coal into energy and material products that can supplement or replace petroleum-based products. The methodological steps in the analysis include: Definition of functional operations that enter into coal conversion processes, and modeling of alternative, competing methods to accomplish these functions; compilation of all feasible conversion processes that can be assembled from combinations of competing methods for the functional operations; systematic, iterative evaluation of all feasible conversion processes under a variety of economic situations, environmental constraints, and projected technological advances; and aggregative assessments (economic and environmental) of various industrial development scenarios. An integral part of the present project is additional development of the existing computer model to include: A data base for coal-related materials and coal conversion processes; and an algorithmic structure that facilitates the iterative, systematic evaluations in response to exogenously specified variables, such as tax policy, environmental limitations, and changes in process technology and costs. As an analytical tool, the analysis is intended to satisfy the needs of an analyst working at the process selection level, for example, with respect to the allocation of RDandD funds to competing technologies.

  4. Process for separating nitrogen from methane using microchannel process technology

    Science.gov (United States)

    Tonkovich, Anna Lee [Marysville, OH; Qiu, Dongming [Dublin, OH; Dritz, Terence Andrew [Worthington, OH; Neagle, Paul [Westerville, OH; Litt, Robert Dwayne [Westerville, OH; Arora, Ravi [Dublin, OH; Lamont, Michael Jay [Hilliard, OH; Pagnotto, Kristina M [Cincinnati, OH

    2007-07-31

    The disclosed invention relates to a process for separating methane or nitrogen from a fluid mixture comprising methane and nitrogen, the process comprising: (A) flowing the fluid mixture into a microchannel separator, the microchannel separator comprising a plurality of process microchannels containing a sorption medium, the fluid mixture being maintained in the microchannel separator until at least part of the methane or nitrogen is sorbed by the sorption medium, and removing non-sorbed parts of the fluid mixture from the microchannel separator; and (B) desorbing the methane or nitrogen from the sorption medium and removing the desorbed methane or nitrogen from the microchannel separator. The process is suitable for upgrading methane from coal mines, landfills, and other sub-quality sources.

  5. Business process reporting using process mining, analytic workflows and process cubes : A case study in education

    NARCIS (Netherlands)

    Bolt Iriondo, A.J.; de Leoni, M.; van der Aalst, W.M.P.; Gorissen, P.; Paolo, C.; Stefanie, R.-M.

    2017-01-01

    Business Process Intelligence (BPI) is an emerging topic that has gained popularity in the last decade. It is driven by the need for analysis techniques that allow businesses to understand and improve their processes. One of the most common applications of BPI is reporting, which consists on the

  6. The plasma hearth process: Process residuals characterization

    International Nuclear Information System (INIS)

    Leatherman, G.L.; Geimer, R.; Batdorf, J.; Hassel, G.; Wolfe, P.; Carney, K.P.

    1994-01-01

    The Plasma Hearth Process (PHP) is a high-temperature waste treatment process being developed by Science Applications International Corporation (SAIC) for the Department of Energy (DOE) that destroys hazardous organics while stabilizing radionuclides and hazardous metals in a vitreous slag waste form. The PHP has potential application for the treatment of a wide range of mixed waste types in both the low-level and transuranic (TRU) mixed waste categories. DOE, through the Office of Technology Development's Mixed Waste Integrated Program (MWIP) is conducting a three phase development project to ready the PHP for implementation in the DOE complex

  7. Process and device for processing radioactive wastes

    International Nuclear Information System (INIS)

    1974-01-01

    A method is described for processing liquid radioactive wastes. It includes the heating of the liquid wastes so that the contained liquids are evaporated and a practically anhydrous mass of solid particles inferior in volume to that of the wastes introduced is formed, then the transformation of the solid particles into a monolithic structure. This transformation includes the compressing of the particles and sintering or fusion. The solidifying agent is a mixture of polyethylene and paraffin wax or a styrene copolymer and a polyester resin. The device used for processing the radioactive liquid wastes is also described [fr

  8. Fermentation process using specific oxygen uptake rates as a process control

    Science.gov (United States)

    Van Hoek, Pim [Minnetonka, MN; Aristidou, Aristos [Maple Grove, MN; Rush, Brian [Minneapolis, MN

    2011-05-10

    Specific oxygen uptake (OUR) is used as a process control parameter in fermentation processes. OUR is determined during at least the production phase of a fermentation process, and process parameters are adjusted to maintain the OUR within desired ranges. The invention is particularly applicable when the fermentation is conducted using a microorganism having a natural PDC pathway that has been disrupted so that it no longer functions. Microorganisms of this sort often produce poorly under strictly anaerobic conditions. Microaeration controlled by monitoring OUR allows the performance of the microorganism to be optimized.

  9. Photon technology. Laser processing technology; Photon technology. Laser process gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-03-01

    Survey has been conducted to develop laser processing technology utilizing the interaction between substance and photon. This is a part of the leading research on photon technology development. The photon technology development is aimed at novel technology development highly utilizing the quantum nature of photons. In the field of laser processing, high quality photons are used as tools, special functions of atoms and molecules will be discovered, and processing for functional fabrication (photon machining) will be established. A role of laser processing in industries has become significant, which is currently spreading not only into cutting and welding of materials and scalpels but also into such a special field as ultrafine processing of materials. The spreading is sometimes obstructed due to the difficulty of procurement of suitable machines and materials, and the increase of cost. The purpose of this study is to develop the optimal laser technology, to elucidate the interaction between substance and photon, and to develop the laser system and the transmission and regulation systems which realize the optimal conditions. 387 refs., 115 figs., 25 tabs.

  10. Process Technical Basis Documentation Diagram for a solid-waste processing facility

    International Nuclear Information System (INIS)

    Benar, C.J.; Petersen, C.A.

    1994-02-01

    The Process Technical Basis Documentation Diagram is for a solid-waste processing facility that could be designed to treat, package, and certify contact-handled mixed low-level waste for permanent disposal. The treatment processes include stabilization using cementitious materials and immobilization using a polymer material. The Diagram identifies several engineering/demonstration activities that would confirm the process selection and process design. An independent peer review was conducted at the request of Westinghouse Hanford Company to determine the technical adequacy of the technical approach for waste form development. The peer review panel provided comments and identified documents that it felt were needed in the Diagram as precedence for Title I design. The Diagram is a visual tool to identify traceable documentation of key activities, including those documents suggested by the peer review, and to show how they relate to each other. The Diagram is divided into three sections: (1) the Facility section, which contains documents pertaining to the facility design, (2) the Process Demonstration section, which contains documents pertaining to the process engineering/demonstration work, and 3) the Regulatory section, which contains documents describing the compliance strategy for each acceptance requirement for each feed type, and how this strategy will be implemented

  11. Flue Gas Desulphurization Processes

    International Nuclear Information System (INIS)

    Aly, A.I.M.; Halhouli, K.A.; Abu-Ashur, B.M.

    1999-01-01

    Flue gas desulphurization process are discussed. These processes can be grouped into non-regenerable systems and regenerable systems. The non-regenerable systems produce a product which is either disposed of as waste or sold as a by-product e.g. lime/limestone process. While in the regenerable systems, e.g. Wellman-Lord process, the SO 2 is regenerated from the sorbent(sodium sulphite), which is returned to absorb more SO 2 . Also a newer technology for flue gas desulphurization is discussed. The Ispra process uses bromine as oxidant, producing HBr, from which bromine is regenerated by electrolysis. The only by-products of this process are sulphuric acid and hydrogen, which are both valuable products, and no waste products are produced. Suggested modifications on the process are made based on experimental investigations to improve the efficiency of the process and to reduce its costs

  12. BPMN process views construction

    NARCIS (Netherlands)

    Yongchareon, S.; Liu, Chengfei; Zhao, X.; Kowalkiewicz, M.; Kitagawa, H.; Ishikawa, Y.

    2010-01-01

    Process view technology is catching more attentions in modern business process management, as it enables the customisation of business process representation. This capability helps improve the privacy protection, authority control, flexible display, etc., in business process modelling. One of

  13. Visual processing in rapid-chase systems: Image processing, attention, and awareness

    Directory of Open Access Journals (Sweden)

    Thomas eSchmidt

    2011-07-01

    Full Text Available Visual stimuli can be classified so rapidly that their analysis may be based on a single sweep of feedforward processing through the visuomotor system. Behavioral criteria for feedforward processing can be evaluated in response priming tasks where speeded pointing or keypress responses are performed towards target stimuli which are preceded by prime stimuli. We apply this method to several classes of complex stimuli. 1 When participants classify natural images into animals or non-animals, the time course of their pointing responses indicates that prime and target signals remain strictly sequential throughout all processing stages, meeting stringent behavioral criteria for feedforward processing (rapid-chase criteria. 2 Such priming effects are boosted by selective visual attention for positions, shapes, and colors, in a way consistent with bottom-up enhancement of visuomotor processing, even when primes cannot be consciously identified. 3 Speeded processing of phobic images is observed in participants specifically fearful of spiders or snakes, suggesting enhancement of feedforward processing by long-term perceptual learning. 4 When the perceived brightness of primes in complex displays is altered by means of illumination or transparency illusions, priming effects in speeded keypress responses can systematically contradict subjective brightness judgments, such that one prime appears brighter than the other but activates motor responses as if it was darker. We propose that response priming captures the output of the first feedforward pass of visual signals through the visuomotor system, and that this output lacks some characteristic features of more elaborate, recurrent processing. This way, visuomotor measures may become dissociated from several aspects of conscious vision. We argue that "fast" visuomotor measures predominantly driven by feedforward processing should supplement "slow" psychophysical measures predominantly based on visual

  14. Assessment of service delays and impact on bed utilisation in a major teaching hospital.

    LENUS (Irish Health Repository)

    Conway, R

    2010-12-14

    BACKGROUND: Increasing economic pressures coupled with an expanding and ageing population and a hostile economic climate have led to growing interest in the optimisation of bed usage within hospitals. There are many causes for delay in a patient\\'s discharge. METHODS: This prospective observational study assessed consecutive patients admitted and discharged from hospital within a 52-day period for waiting times in the provision of requested diagnostic tests and services. RESULTS: Seventy patients were included in the study. There were median delays of 2 and 3 days for an MRI and colonoscopy, a delay of 3 days for a Holter monitor report, and 9 days for an occupational therapy referral. The median wait for consults was 1 day across all three services. CONCLUSIONS: Significant remediable delays exist during the course of many acute medical admissions. Addressing these factors will enable the provision of a faster and more cost-efficient service.

  15. Identifying drug-induced repolarization abnormalities from distinct ECG patterns in congenital long QT syndrome: a study of sotalol effects on T-wave morphology

    DEFF Research Database (Denmark)

    Graff, Claus; Andersen, Mads P; Xue, Joel Q

    2009-01-01

    BACKGROUND: The electrocardiographic QT interval is used to identify drugs with potential harmful effects on cardiac repolarization in drug trials, but the variability of the measurement can mask drug-induced ECG changes. The use of complementary electrocardiographic indices of abnormal repolariz......BACKGROUND: The electrocardiographic QT interval is used to identify drugs with potential harmful effects on cardiac repolarization in drug trials, but the variability of the measurement can mask drug-induced ECG changes. The use of complementary electrocardiographic indices of abnormal...... are typical ECG patterns in LQT2. Blinded to labels, the new morphology measures were tested in a third group of 39 healthy subjects receiving sotalol. Over 3 days the sotalol group received 0, 160 and 320 mg doses, respectively, and a 12-lead Holter ECG was recorded for 22.5 hours each day. Drug...... with QTcF, p ECG patterns in LQT2 carriers effectively quantified repolarization changes induced by sotalol. Further studies are needed to validate whether this measure has...

  16. 77-year-old female with syncope.

    Science.gov (United States)

    Abdelsalam, Mahmoud A; Geske, Jeffrey B

    2017-02-15

    A 77-year-old female was referred for evaluation of an episode of syncope while eating breakfast. There was no history of fall, syncope, prodrome, dyspnoea, chest discomfort or palpitations. Medical history was notable for hyperlipidaemia and treated hypertension. Blood pressure was 140/90 mm Hg, pulse 85  beats per minute (BPM). No murmurs were present on cardiac examination. ECG revealed normal sinus rhythm with left ventricular (LV) hypertrophy (see online supplementary figure S1). Holter monitor demonstrated rare premature ventricular complexes (<1% of beats), without heart block or ventricular tachycardia. Transthoracic echocardiogram is shown in figure 1. Which of the following is the explanation for the flow indicated by the yellow arrow? Aortic stenosisCoronary artery flow, indicative of coronary fistulaHypertrophic cardiomyopathy with apical pouchHypertensive heart diseaseMitral stenosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals

    Directory of Open Access Journals (Sweden)

    Isabel G. Trindade

    2016-09-01

    Full Text Available This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  18. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals.

    Science.gov (United States)

    Trindade, Isabel G; Machado da Silva, José; Miguel, Rui; Pereira, Madalena; Lucas, José; Oliveira, Luís; Valentim, Bruno; Barreto, Jorge; Santos Silva, Manuel

    2016-09-24

    This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  19. EFFECT OF ANTIHYPERTENSIVE THERAPY BASED ON NEW METHOD OF INDIVIDUAL CHOICE OF DRUGS ON LEFT VENTRICULAR HYPERTROPHY IN ELDERLY PATIENTS

    Directory of Open Access Journals (Sweden)

    K. I. Pshenichkin

    2015-12-01

    Full Text Available Aim. To study the effects of antihypertensive therapy based on consideration of individual heart rhythm variability (HRV on left ventricular hypertrophy (LVH in hypertensive elderly patients.Material and methods. 60 hypertensive elderly patients with LVH were included in the study. They were split in two groups (30 people in each one. Patients of the group-I had common antihypertensive therapy. Patients of group-II received medications prescribed with consideration of individual heart rate variability. Holter monitoring with analysis of HRV, 24-hour blood pressure monitoring and ultrasonography were conducted initially and 18 months after treatment beginning.Results. BP control was reached in the majority of patients of both groups. The patients of group-II in comparison with patients of group-I had reduction of low- high frequency power ratio (LF/HF and higher rate of LVH reduction. Relationship between LVH dynamics and ratio LF/HF was found.Conclusion. Arterial hypertension therapy considering individual HRV contributes in LVH reduction in elderly patients.

  20. Perioperative Rosuvastatin in Cardiac Surgery.

    Science.gov (United States)

    Zheng, Zhe; Jayaram, Raja; Jiang, Lixin; Emberson, Jonathan; Zhao, Yan; Li, Qi; Du, Juan; Guarguagli, Silvia; Hill, Michael; Chen, Zhengming; Collins, Rory; Casadei, Barbara

    2016-05-05

    Complications after cardiac surgery are common and lead to substantial increases in morbidity and mortality. Meta-analyses of small randomized trials have suggested that perioperative statin therapy can prevent some of these complications. We randomly assigned 1922 patients in sinus rhythm who were scheduled for elective cardiac surgery to receive perioperative rosuvastatin (at a dose of 20 mg daily) or placebo. The primary outcomes were postoperative atrial fibrillation within 5 days after surgery, as assessed by Holter electrocardiographic monitoring, and myocardial injury within 120 hours after surgery, as assessed by serial measurements of the cardiac troponin I concentration. Secondary outcomes included major in-hospital adverse events, duration of stay in the hospital and intensive care unit, left ventricular and renal function, and blood biomarkers. The concentrations of low-density lipoprotein cholesterol and C-reactive protein after surgery were lower in patients assigned to rosuvastatin than in those assigned to placebo (PSTICS ClinicalTrials.gov number, NCT01573143.).

  1. Electrocardiographic Patch Devices and Contemporary Wireless Cardiac Monitoring

    Directory of Open Access Journals (Sweden)

    Erik eFung

    2015-05-01

    Full Text Available Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG, Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable ‘on-body’ ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.

  2. Detection of ST-T Episode Based on the Global Curvature of Isoelectric Level in ECG

    Energy Technology Data Exchange (ETDEWEB)

    Kang, D. W.; Jun, D. G.; Lee, K. J.; Yoon, H. R. [Yonsei University, Seoul (Korea)

    2001-04-01

    This paper describes an automated detection algorithm of ST-T episodes using global curvature which can connect the isoelectric level in ECG and can eliminate not only the slope of ST segment, but also difference of the baseline and global curve. This above method of baseline correction is very faster than classical baseline correction methods. The optimal values of parameters for baseline correction were found as the value having the highest detection rate of ST episode. The features as input of backpropagation Neural Network were extracted from the whole ST segment. The European ST-T database was used as training and test data. Finally, ST elevation, ST depression and normal ST were classified. The average ST episode sensitivity and predictivity were 85.42%, 80.29%, respectively. This result shows the high speed and reliability in ST episode detection. In conclusion, the proposed method showed the possibility in various applications for the Holter system. (author). 17 refs., 5 figs., 4 tabs.

  3. QT dynamics during treatment with sertindole

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Wang, Fan; Graff, Claus

    2015-01-01

    be revealed by dynamic measures of the QT interval such as the ratio of QT variability to heart rate variability (variability ratio [VR]). The aim of this study was to investigate the effect of sertindole on QT dynamics. METHODS: QTc and the VR were assessed in an observational study using 24-hour Holter...... monitoring at baseline and after 3 weeks of treatment with sertindole 16 mg. The VR was calculated by dividing the standard deviation of QT intervals with the standard deviation of heart rates. Outcome measures were compared using paired t-test. RESULTS: A total of 18 patients participated in the study, two...... were excluded from further analysis due to low amplitude of the T-wave. When patients were shifted to sertindole, the VR increased from 0.192 (SD 0.045) to 0.223 (SD 0.061), p = 0.02. The QTcF interval increased from 388 (SD 16) to 403 ms (SD 14), p = 0.002. There was no difference in heart rate 78 bpm...

  4. [Therapy of arrhythmia induced by myocardial ischemia. Association of L-carnitine, propafenone and mexiletine].

    Science.gov (United States)

    Mondillo, S; Faglia, S; D'Aprile, N; Mangiacotti, L; Campolo, M A; Agricola, E; Palazzuoli, V

    1995-12-01

    To assess the anti-arrythmic effect of L-carnitina, propafenone and mexiletine, we tested the drugs in 50 patients with effort angina and ventricular ectopic beats (VEB). The patients were randomized in 5 groups: Group A: was treated with oral L-carnitine at the dose of 2 g x 3 for two weeks. Group B: oral propafenone at the dose of 300 mg x 3 for two weeks. Group C: as group B+L-carnitine+g x 3 at the second weeks. Group D: oral mexiletine at the dose of 200 mg x 3 for two weeks. Group E: as group D+L-carnitine 2 gr x 3 at the second week. After 7 and 14 days of treatment, in all patients an Holter examination was performed. Our results show that L-carnitine exerts a significant reduction of the VEB and its administration potentiates the anti-arrythmic effect of propafenone and mexiletine.

  5. Haptoglobin Phenotype Predicts a Low Heart Rate Variability in Patients with Chronic Kidney Disease

    DEFF Research Database (Denmark)

    Svensson, My; Strandhave, Charlotte; Krarup, H.B.

    2009-01-01

    whether Hp phenotyping in patients with CKD could identify a group of high-risk patients according to HRV measurements. Methods: Patients (n = 61) were recruited from our outpatient clinic. They were eligible if they had CKD, defined as a plasma creatinine level between 1.70 and 4.52 mg/dL, for more than...... 3 months. The Hp phenotype was determined using a high-performance liquid chromatography. Furthermore, a 24-hour Holter recording was obtained in each patient for analysis of 24-h HRV indices in the time domain. Results: The CKD patients in the three groups [phenotypes Hp 1-1 (n=12), Hp 2-1 (n=32......), and Hp 2-2 (n=17)] were comparable regarding clinical relevant parameters such as age, plasma creatinine, body mass index, PTH level, and haemoglobin. Furthermore, sodium-, potassium-, and calcium levels were within normal range in all patients. The HRV parameter SDNN (SD of all normal RR...

  6. The impact of supraventricular ectopic complexes in different age groups and risk of recurrent atrial fibrillation after antiarrhythmic medication or catheter ablation

    DEFF Research Database (Denmark)

    Alhede, Christina; Lauridsen, Trine K; Johannessen, Arne

    2018-01-01

    INTRODUCTION: Supraventricular ectopic complexes (SVEC) are known risk factors of recurrent atrial fibrillation (AF). However, the impact of SVEC in different age groups is unknown. We aimed to investigate the risk of AF recurrence with higher SVEC burden in patients ±57years, respectively, after....... RESULTS: Age >57years were significantly associated with higher AF recurrence rate after CA (58% vs 36%, p=0.02). After CA, we observed a higher SVEC burden during follow-up in patients >57years which was not observed in the younger age group treated with CA (p=0.006). High SVEC burden at 3months after CA...... treatment with antiarrhythmic medication (AAD) or catheter ablation (CA). METHODS: In total, 260 patients with LVEF >40% and age ≤70 years were randomized to AAD (N=132) or CA (N=128) as first-line treatment for paroxysmal AF. All patients underwent 7-day Holter monitoring at baseline, and after 3, 6, 12...

  7. [Non-invasive exploration methods of supraventricular arrhythmia in current practice].

    Science.gov (United States)

    Fauchier, J P; Fauchier, L; Babuty, D; Sirinelli, A; Cosnay, P

    1993-06-15

    In patients with supraventricular rhythm disorders ambulatory electro-cardiographic recording (Holter system) is an indispensable examination as it detects attacks that pass unrecorded by conventional ECG, being asymptomatic, too brief or too rare. It confirms the diagnosis, defines the factors triggering the attacks, detects the association of rhythm and conduction disorders, guides the treatment and monitors its effectiveness. Sequential ambulatory recording lends itself particularly well to this last objective. Biochemical examinations explain the cause of certain relapses (potassium depletion, high alcohol blood level) or detect the origin, clinically more or less obvious, of these disorders of rhythm (essays of thyroid hormones). Measuring blood levels of therapeutic drugs makes the handling of these various drugs safer. Finally, echocardiography detects an underlying heart disease, evaluates the size of the left atrium (a factor of relapse when it is dilated and of embolism when it harbours thrombi) and assesses the left ventricular function before administration of antiarrhythmics which, to varying extents, are all negative inotropic drugs.

  8. Evaluation of the sympathetic nervous system in silent ischemia with 123I-metaiodobenzylguanidine (MIBG)

    International Nuclear Information System (INIS)

    Guertner, C.; Schacherer, C.; Krause, B.J.; Zickmann, J.; Klepzig, H. Jr.; Hoer, G.

    1996-01-01

    Stress and rest myocardial perfusion scintigraphy using either Thallium-201 or 99m Tc-isonitrile was performed in SPECT technique in order to localize ischemia or scar associated perfusion defects. 15 min and 4 h p.i. static anterior 123 I-MIBG uptake was acquired. In order to localize norepinephrine depletion 4 h p.i. additional 123 I-MIBG SPECT acquistion was performed. Incidence of arrhythmias was investigated by Holter ECG. Patients with diabetes mellitus were excluded. SPECT images showed in all patients regional 123 I-MIBG depletion which corresponded with scintigraphically infarcted or ischemic regions. Well perfused myocardial regions matched with regular 123 I-MIBG utpake. There was no evidence of increased arrhythmias in long-term ECG. The finding of regular 123 I-MIBG uptake in well-perfused myocardium and infarction- or ischemia-associated regional 123 I-MIBG depletion confirms that silent ischemia is not caused by a global sympathetic nervous dysfunction in a sense of cardiac polyneuropathy. (orig.) [de

  9. Cryptogenic embolic stroke in a girl with a trisomy 21 mosaic.

    Science.gov (United States)

    Stöllberger, Claudia; Weiss, Simone; Zlabinger, Gerhard; Finsterer, Josef

    2012-06-01

    Stroke in trisomy 21 may be due to cardioembolism, atherosclerosis, vasculitis, moyamoya disease, sinus venous thrombosis, internal carotid hypoplasia or infections like endocarditis with septic emboli, meningitis or brain abscess. In rare cases, however, stroke etiology remains unexplained. We present a 19 year old Caucasian girl with trisomy 21 with a 47XX+21 karyotype who suffered at age 11 years from a transient ischemic attack with left hemiparesis, and at age 17 years from an ischemic stroke in the territory of the right cerebral medial artery. She suffered from arterial hypertension, obesity and hypercholesterolemia. Since blood coagulation studies, immunologic parameters, blood cultures, 24-h Holter monitoring, transthoracic and transesophageal echocardiography, magnetic resonance angiography of the extra- and intracranial vessels, thoracic and abdominal aorta and renal arteries did not provide any explanation for the stroke, implantation of a loop recorder is considered in order to detect episodes of clinically silent atrial fibrillation.

  10. Pheochromocytoma diagnosed after anticoagulation for atrial fibrillation ablation procedure: a giant in disguise.

    Science.gov (United States)

    Galvão Braga, Carlos; Ribeiro, Sílvia; Martins, Juliana; Arantes, Carina; Ramos, Vítor; Primo, João; Magalhães, Sónia; Correia, Adelino

    2014-04-01

    Pheochromocytoma is a rare catecholamine-producing tumor, discovered incidentally in 50% of cases. We present the case of a 44-year-old male with a history of paroxysmal palpitations. Baseline ECG, transthoracic echocardiogram and ECG stress test showed no relevant alterations. Paroxysmal atrial fibrillation was detected on 24-hour Holter ECG. After antiarrhythmic therapy, the patient remained symptomatic, and was accordingly referred for electrophysiological study and atrial fibrillation ablation. Anticoagulation was initiated before the procedure. After ablation and still anticoagulated, he complained of hematospermia. The abdominal and pelvic imaging study showed a 10-cm left adrenal mass, predominantly cystic, compatible with pheochromocytoma, which was confirmed after biochemical tests (increased urine metanephrines and plasma catecholamines). Metaiodobenzylguanidine scintigraphy scanning confirmed localized disease in the adrenal gland, excluding other uptake foci. Following appropriate preoperative management, surgical resection of the giant mass was performed successfully and without complications. Copyright © 2013 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  11. Exercise training improves autonomic profiles in patients with Charcot-Marie-Tooth disease.

    Science.gov (United States)

    El Mhandi, Lhassan; Pichot, Vincent; Calmels, Paul; Gautheron, Vincent; Roche, Frédéric; Féasson, Léonard

    2011-11-01

    The effect of an interval exercise training (ITE) program on heart rate variability (HRV) was studied in 8 patients with Charcot-Marie-Tooth (CMT) disease and 8 healthy controls. At baseline, all subjects underwent ambulatory 24-hour Holter electrocardiographic (ECG) monitoring to evaluate HRV. HRV analysis was repeated on CMT patients after they completed a 24-week ITE program on a cycle ergometer. Before exercise, all HRV indices were lower in patients compared with controls, and the difference reached statistical significance for pNN50 (percent of differences between adjacent R-R intervals exceeding 50 ms). After ITE, time- and frequency-domain indices were significantly improved, particularly at night (+8% mean R-R interval, +95% pNN50, 52% reduction in low/high-frequency ratio). We observed significant increases in some of the time and frequency parameters, and values sometimes exceeded those of controls at baseline. Our results suggest that ITE improves HRV modulation in CMT patients by enhancing parasympathetic activity. Copyright © 2011 Wiley Periodicals, Inc.

  12. A survey of process control computers at the Idaho Chemical Processing Plant

    International Nuclear Information System (INIS)

    Dahl, C.A.

    1989-01-01

    The Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory is charged with the safe processing of spent nuclear fuel elements for the United States Department of Energy. The ICPP was originally constructed in the late 1950s and used state-of-the-art technology for process control at that time. The state of process control instrumentation at the ICPP has steadily improved to keep pace with emerging technology. Today, the ICPP is a college of emerging computer technology in process control with some systems as simple as standalone measurement computers while others are state-of-the-art distributed control systems controlling the operations in an entire facility within the plant. The ICPP has made maximal use of process computer technology aimed at increasing surety, safety, and efficiency of the process operations. Many benefits have been derived from the use of the computers for minimal costs, including decreased misoperations in the facility, and more benefits are expected in the future

  13. Process evaluation distributed system

    Science.gov (United States)

    Moffatt, Christopher L. (Inventor)

    2006-01-01

    The distributed system includes a database server, an administration module, a process evaluation module, and a data display module. The administration module is in communication with the database server for providing observation criteria information to the database server. The process evaluation module is in communication with the database server for obtaining the observation criteria information from the database server and collecting process data based on the observation criteria information. The process evaluation module utilizes a personal digital assistant (PDA). A data display module in communication with the database server, including a website for viewing collected process data in a desired metrics form, the data display module also for providing desired editing and modification of the collected process data. The connectivity established by the database server to the administration module, the process evaluation module, and the data display module, minimizes the requirement for manual input of the collected process data.

  14. Development of processes for the utilization of Brazilian coal using nuclear process heat and/or nuclear process steam

    International Nuclear Information System (INIS)

    Bamert, H.; Niessen, H.F.; Walbeck, M.; Wasrzik, U.; Mueller, R.; Schiffers, U.; Strauss, W.

    1980-01-01

    Status of the project: End of the project definition phase and preparation of the planned conceptual phase. Objective of the project: Development of processes for the utilization of nuclear process heat and/or nuclear process steam for the gasification of coal with high ash content, in particular coal from Brazil. Results: With the data of Brazilian coal of high ash content (mine Leao/ 43% ash in the mine-mouth quality, 20% ash after preparation) there have been worked out proposals for the mine planning and for a number of processes. On the basis of these proposals and under consideration of the main data specified by the Brazilian working group there have been choosen two processes and worked out in a conceptual design: 1) pressurized water reactor + LURGI-pressure gasifier/hydrogasification for the production of SNG and 2) high temperature reactor steam gasification for the production of town gas. The economic evaluation showed that the two processes are not substantially different in their cost efficiency and they are economical on a long-term basis. For more specific design work there has been planned the implementation of an experimental programme using the semi-technical plants 'hydrogasification' in Wesseling and 'steam gasification' in Essen as the conceptual phase. (orig.) [de

  15. Improving the Document Development Process: Integrating Relational Data and Statistical Process Control.

    Science.gov (United States)

    Miller, John

    1994-01-01

    Presents an approach to document numbering, document titling, and process measurement which, when used with fundamental techniques of statistical process control, reveals meaningful process-element variation as well as nominal productivity models. (SR)

  16. Fuel processing. Wastes processing

    International Nuclear Information System (INIS)

    Bourgeois, M.

    2000-01-01

    The gaseous, liquid and solid radioactive effluents generated by the fuel reprocessing, can't be release in the environment. They have to be treated in order to respect the limits of the pollution regulations. These processing are detailed and discussed in this technical paper. A second part is devoted to the SPIN research program relative to the separation of the long life radionuclides in order to reduce the radioactive wastes storage volume. (A.L.B.)

  17. Exploring processes and deviations

    NARCIS (Netherlands)

    Leemans, S.J.J.; Fahland, D.; Aalst, van der W.M.P.; Fournier, F.; Mendling, J.

    2015-01-01

    In process mining, one of the main challenges is to discover a process model, while balancing several quality criteria. This often requires repeatedly setting parameters, discovering a map and evaluating it, which we refer to as process exploration. Commercial process mining tools like Disco,

  18. Process for winning uranium from wet process phosphoric acid

    International Nuclear Information System (INIS)

    1980-01-01

    A process is described for winning uranium from wet process phosphoric acid by means of liquid-liquid extraction with organic phosphoric acid esters. The process is optimised by keeping the sulphate percentage in the phosphoric acid below 2% by weight, and preferably below 0.6% by weight, as compared to P 2 O 5 in the phosphoric acid. This is achieved by adding an excess of Ba and/or Ca carbonate or sulfide solution and filtering off the formed calcium and/or barium sulphate precipitates. Solid KClO 3 is then added to the filtrate to oxidise U 4+ to U 6+ . The normal extraction procedure using organic phosphoric esters as extraction liquid, can then be applied. (Th.P.)

  19. Product- and Process Units in the CRITT Translation Process Research Database

    DEFF Research Database (Denmark)

    Carl, Michael

    than 300 hours of text production. The database provides the raw logging data, as well as Tables of pre-processed product- and processing units. The TPR-DB includes various types of simple and composed product and process units that are intended to support the analysis and modelling of human text......The first version of the "Translation Process Research Database" (TPR DB v1.0) was released In August 2012, containing logging data of more than 400 translation and text production sessions. The current version of the TPR DB, (v1.4), contains data from more than 940 sessions, which represents more...

  20. Poisson branching point processes

    International Nuclear Information System (INIS)

    Matsuo, K.; Teich, M.C.; Saleh, B.E.A.

    1984-01-01

    We investigate the statistical properties of a special branching point process. The initial process is assumed to be a homogeneous Poisson point process (HPP). The initiating events at each branching stage are carried forward to the following stage. In addition, each initiating event independently contributes a nonstationary Poisson point process (whose rate is a specified function) located at that point. The additional contributions from all points of a given stage constitute a doubly stochastic Poisson point process (DSPP) whose rate is a filtered version of the initiating point process at that stage. The process studied is a generalization of a Poisson branching process in which random time delays are permitted in the generation of events. Particular attention is given to the limit in which the number of branching stages is infinite while the average number of added events per event of the previous stage is infinitesimal. In the special case when the branching is instantaneous this limit of continuous branching corresponds to the well-known Yule--Furry process with an initial Poisson population. The Poisson branching point process provides a useful description for many problems in various scientific disciplines, such as the behavior of electron multipliers, neutron chain reactions, and cosmic ray showers

  1. Investigation of Mediational Processes Using Parallel Process Latent Growth Curve Modeling

    Science.gov (United States)

    Cheong, JeeWon; MacKinnon, David P.; Khoo, Siek Toon

    2010-01-01

    This study investigated a method to evaluate mediational processes using latent growth curve modeling. The mediator and the outcome measured across multiple time points were viewed as 2 separate parallel processes. The mediational process was defined as the independent variable influencing the growth of the mediator, which, in turn, affected the growth of the outcome. To illustrate modeling procedures, empirical data from a longitudinal drug prevention program, Adolescents Training and Learning to Avoid Steroids, were used. The program effects on the growth of the mediator and the growth of the outcome were examined first in a 2-group structural equation model. The mediational process was then modeled and tested in a parallel process latent growth curve model by relating the prevention program condition, the growth rate factor of the mediator, and the growth rate factor of the outcome. PMID:20157639

  2. A Campbell random process

    International Nuclear Information System (INIS)

    Reuss, J.D.; Misguich, J.H.

    1993-02-01

    The Campbell process is a stationary random process which can have various correlation functions, according to the choice of an elementary response function. The statistical properties of this process are presented. A numerical algorithm and a subroutine for generating such a process is built up and tested, for the physically interesting case of a Campbell process with Gaussian correlations. The (non-Gaussian) probability distribution appears to be similar to the Gamma distribution

  3. Weak convergence of marked point processes generated by crossings of multivariate jump processes

    DEFF Research Database (Denmark)

    Tamborrino, Massimiliano; Sacerdote, Laura; Jacobsen, Martin

    2014-01-01

    We consider the multivariate point process determined by the crossing times of the components of a multivariate jump process through a multivariate boundary, assuming to reset each component to an initial value after its boundary crossing. We prove that this point process converges weakly...... process converging to a multivariate Ornstein–Uhlenbeck process is discussed as a guideline for applying diffusion limits for jump processes. We apply our theoretical findings to neural network modeling. The proposed model gives a mathematical foundation to the generalization of the class of Leaky...

  4. Business process quality management

    NARCIS (Netherlands)

    Reijers, H.A.; Mendling, J.; Recker, J.; Brocke, vom J.; Rosemann, M.

    2010-01-01

    Abstract Process modeling is a central element in any approach to Business Process Management (BPM). However, what hinders both practitioners and aca demics is the lack of support for assessing the quality of process models — let alone realizing high quality process models. Existing frameworks are

  5. Distributed genetic process mining

    NARCIS (Netherlands)

    Bratosin, C.C.; Sidorova, N.; Aalst, van der W.M.P.

    2010-01-01

    Process mining aims at discovering process models from data logs in order to offer insight into the real use of information systems. Most of the existing process mining algorithms fail to discover complex constructs or have problems dealing with noise and infrequent behavior. The genetic process

  6. 7 Processes that Enable NASA Software Engineering Technologies: Value-Added Process Engineering

    Science.gov (United States)

    Housch, Helen; Godfrey, Sally

    2011-01-01

    The presentation reviews Agency process requirements and the purpose, benefits, and experiences or seven software engineering processes. The processes include: product integration, configuration management, verification, software assurance, measurement and analysis, requirements management, and planning and monitoring.

  7. Motivated information processing and group decision-making : Effects of process accountability on information processing and decision quality

    NARCIS (Netherlands)

    Scholten, Lotte; van Knippenberg, Daan; Nijstad, Bernard A.; De Dreu, Carsten K. W.

    Integrating dual-process models [Chaiken, S., & Trope, Y. (Eds.). (1999). Dual-process theories in social psychology. NewYork: Guilford Press] with work on information sharing and group decision-making [Stasser, G., & Titus, W. (1985). Pooling of unshared information in group decision making: biased

  8. FFTF gas processing systems

    International Nuclear Information System (INIS)

    Halverson, T.G.

    1977-01-01

    The design and operation of the two radioactive gas processing systems at the Fast Flux Test Facility (FFTF) exemplifies the concept that will be used in the first generation of Liquid Metal Fast Breeder Reactors (LMFBR's). The two systems, the Radioactive Argon Processing System (RAPS) and the Cell Atmosphere Processing System (CAPS), process the argon and nitrogen used in the FFTF for cover gas on liquid metal systems and as inert atmospheres in steel lined cells housing sodium equipment. The RAPS specifically processes the argon cover gas from the reactor coolant system, providing for decontamination and eventual reuse. The CAPS processes radioactive gasses from inerted cells and other liquid metal cover gas systems, providing for decontamination and ultimate discharge to the atmosphere. The cryogenic processing of waste gas by both systems is described

  9. Sustainable Process Synthesis-Intensification

    DEFF Research Database (Denmark)

    Babi, Deenesh Kavi; Holtbruegge, Johannes; Lutze, Philip

    2014-01-01

    Sustainable process design can be achieved by performing process synthesis and process intensification together. This approach first defines a design target through a sustainability analysis and then finds design alternatives that match the target through process intensification. A systematic......, multi-stage framework for process synthesis- intensification that identifies more sustainable process designs has been developed. At stages 1-2, the working scale is at the level of unit operations, where a base case design is identified and analyzed with respect to sustainability metrics. At stages 3......, a phenomena-based process synthesis method is applied, where the phenomena involved in each tasks are identified, manipulated and recombined to generate new and/or existing unit operations configured into flowsheets that are more sustainable from those found in the previous levels. An overview of the key...

  10. Feller processes: the next generation in modeling. Brownian motion, Lévy processes and beyond.

    Directory of Open Access Journals (Sweden)

    Björn Böttcher

    Full Text Available We present a simple construction method for Feller processes and a framework for the generation of sample paths of Feller processes. The construction is based on state space dependent mixing of Lévy processes. Brownian Motion is one of the most frequently used continuous time Markov processes in applications. In recent years also Lévy processes, of which Brownian Motion is a special case, have become increasingly popular. Lévy processes are spatially homogeneous, but empirical data often suggest the use of spatially inhomogeneous processes. Thus it seems necessary to go to the next level of generalization: Feller processes. These include Lévy processes and in particular brownian motion as special cases but allow spatial inhomogeneities. Many properties of Feller processes are known, but proving the very existence is, in general, very technical. Moreover, an applicable framework for the generation of sample paths of a Feller process was missing. We explain, with practitioners in mind, how to overcome both of these obstacles. In particular our simulation technique allows to apply Monte Carlo methods to Feller processes.

  11. Standard Model processes

    CERN Document Server

    Mangano, M.L.; Aguilar-Saavedra, Juan Antonio; Alekhin, S.; Badger, S.; Bauer, C.W.; Becher, T.; Bertone, V.; Bonvini, M.; Boselli, S.; Bothmann, E.; Boughezal, R.; Cacciari, M.; Carloni Calame, C.M.; Caola, F.; Campbell, J.M.; Carrazza, S.; Chiesa, M.; Cieri, L.; Cimaglia, F.; Febres Cordero, F.; Ferrarese, P.; D'Enterria, D.; Ferrera, G.; Garcia i Tormo, X.; Garzelli, M.V.; Germann, E.; Hirschi, V.; Han, T.; Ita, H.; Jäger, B.; Kallweit, S.; Karlberg, A.; Kuttimalai, S.; Krauss, F.; Larkoski, A.J.; Lindert, J.; Luisoni, G.; Maierhöfer, P.; Mattelaer, O.; Martinez, H.; Moch, S.; Montagna, G.; Moretti, M.; Nason, P.; Nicrosini, O.; Oleari, C.; Pagani, D.; Papaefstathiou, A.; Petriello, F.; Piccinini, F.; Pierini, M.; Pierog, T.; Pozzorini, S.; Re, E.; Robens, T.; Rojo, J.; Ruiz, R.; Sakurai, K.; Salam, G.P.; Salfelder, L.; Schönherr, M.; Schulze, M.; Schumann, S.; Selvaggi, M.; Shivaji, A.; Siodmok, A.; Skands, P.; Torrielli, P.; Tramontano, F.; Tsinikos, I.; Tweedie, B.; Vicini, A.; Westhoff, S.; Zaro, M.; Zeppenfeld, D.; CERN. Geneva. ATS Department

    2017-06-22

    This report summarises the properties of Standard Model processes at the 100 TeV pp collider. We document the production rates and typical distributions for a number of benchmark Standard Model processes, and discuss new dynamical phenomena arising at the highest energies available at this collider. We discuss the intrinsic physics interest in the measurement of these Standard Model processes, as well as their role as backgrounds for New Physics searches.

  12. Classical higher-order processes

    DEFF Research Database (Denmark)

    Montesi, Fabrizio

    2017-01-01

    Classical Processes (CP) is a calculus where the proof theory of classical linear logic types processes à la Π-calculus, building on a Curry-Howard correspondence between session types and linear propositions. We contribute to this research line by extending CP with process mobility, inspired...... by the Higher-Order Π-calculus. The key to our calculus is that sequents are asymmetric: one side types sessions as in CP and the other types process variables, which can be instantiated with process values. The controlled interaction between the two sides ensures that process variables can be used at will......, but always respecting the linear usage of sessions expected by the environment....

  13. Process margin enhancement for 0.25-μm metal etch process

    Science.gov (United States)

    Lee, Chung Y.; Ma, Wei Wen; Lim, Eng H.; Cheng, Alex T.; Joy, Raymond; Ross, Matthew F.; Wong, Selmer S.; Marlowe, Trey

    2000-06-01

    This study evaluates electron beam stabilization of UV6, a positive tone Deep-UV (DUV) resist from Shipley, for a 0.25 micrometer metal etch application. Results are compared between untreated resist and resist treated with different levels of electron beam stabilization. The electron beam processing was carried out in an ElectronCureTM flood electron beam exposure system from Honeywell International Inc., Electron Vision. The ElectronCureTM system utilizes a flood electron beam source which is larger in diameter than the substrate being processed, and is capable of variable energy so that the electron range is matched to the resist film thickness. Changes in the UV6 resist material as a result of the electron beam stabilization are monitored via spectroscopic ellipsometry for film thickness and index of refraction changes and FTIR for analysis of chemical changes. Thermal flow stability is evaluated by applying hot plate bakes of 150 degrees Celsius and 200 degrees Celsius, to patterned resist wafers with no treatment and with an electron beam dose level of 2000 (mu) C/cm2. A significant improvement in the thermal flow stability of the patterned UV6 resist features is achieved with the electron beam stabilization process. Etch process performance of the UV6 resist was evaluated by performing a metal pattern transfer process on wafers with untreated resist and comparing these with etch results on wafers with different levels of electron beam stabilization. The etch processing was carried out in an Applied Materials reactor with an etch chemistry including BCl3 and Cl2. All wafers were etched under the same conditions and the resist was treated after etch to prevent further erosion after etch but before SEM analysis. Post metal etch SEM cross-sections show the enhancement in etch resistance provided by the electron beam stabilization process. Enhanced process margin is achieved as a result of the improved etch resistance, and is observed in reduced resist side

  14. Quality Control in Automated Manufacturing Processes – Combined Features for Image Processing

    Directory of Open Access Journals (Sweden)

    B. Kuhlenkötter

    2006-01-01

    Full Text Available In production processes the use of image processing systems is widespread. Hardware solutions and cameras respectively are available for nearly every application. One important challenge of image processing systems is the development and selection of appropriate algorithms and software solutions in order to realise ambitious quality control for production processes. This article characterises the development of innovative software by combining features for an automatic defect classification on product surfaces. The artificial intelligent method Support Vector Machine (SVM is used to execute the classification task according to the combined features. This software is one crucial element for the automation of a manually operated production process

  15. The creation of process redesigns by selecting, transforming and replacing process parts

    NARCIS (Netherlands)

    Netjes, M.; Reijers, H.A.; Aalst, van der W.M.P.

    2008-01-01

    For companies to sustain competitive advantages, it is required to redesign and improve business processes continuously by monitoring and analyzing process enactment results. Furthermore, organizational structures must be redesigned according to the changes in business processes. However, there are

  16. Hierarchical process memory: memory as an integral component of information processing

    Science.gov (United States)

    Hasson, Uri; Chen, Janice; Honey, Christopher J.

    2015-01-01

    Models of working memory commonly focus on how information is encoded into and retrieved from storage at specific moments. However, in the majority of real-life processes, past information is used continuously to process incoming information across multiple timescales. Considering single unit, electrocorticography, and functional imaging data, we argue that (i) virtually all cortical circuits can accumulate information over time, and (ii) the timescales of accumulation vary hierarchically, from early sensory areas with short processing timescales (tens to hundreds of milliseconds) to higher-order areas with long processing timescales (many seconds to minutes). In this hierarchical systems perspective, memory is not restricted to a few localized stores, but is intrinsic to information processing that unfolds throughout the brain on multiple timescales. “The present contains nothing more than the past, and what is found in the effect was already in the cause.”Henri L Bergson PMID:25980649

  17. Process mining applied to the test process of wafer steppers in ASML

    NARCIS (Netherlands)

    Rozinat, A.; Jong, de I.S.M.; Günther, C.W.; Aalst, van der W.M.P.

    2009-01-01

    Process mining techniques attempt to extract nontrivial and useful information from event logs. For example, there are many process mining techniques to automatically discover a process model describing the causal dependencies between activities. Several successful case studies have been reported in

  18. Welding process

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    For the final chapter of this book, there is basic introduction on welding process. The good radiography must know somehow on welding process so that they can know what kind of welding that must rejected or not. All of the exposure technique that mention in earlier chapter almost applicable in this field because welding process is critical problem if there is no inspection will be done. So, for this chapter, all the discontinuity that usually appeared will be discussed and there is another discontinuity maybe not to important and do not give big impact if found it, do not described here. On top of that, the decision to accept or reject based on code, standard and specification that agreed by both to make sure that decision that agreed is corrected and more meaningful.

  19. Multivariate supOU processes

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler; Stelzer, Robert

    Univariate superpositions of Ornstein-Uhlenbeck (OU) type processes, called supOU processes, provide a class of continuous time processes capable of exhibiting long memory behaviour. This paper introduces multivariate supOU processes and gives conditions for their existence and finiteness...... of moments. Moreover, the second order moment structure is explicitly calculated, and examples exhibit the possibility of long range dependence. Our supOU processes are defined via homogeneous and factorisable Lévy bases. We show that the behaviour of supOU processes is particularly nice when the mean...... reversion parameter is restricted to normal matrices and especially to strictly negative definite ones.For finite variation Lévy bases we are able to give conditions for supOU processes to have locally bounded càdlàg paths of finite variation and to show an analogue of the stochastic differential equation...

  20. Multivariate supOU processes

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler; Stelzer, Robert

    2011-01-01

    Univariate superpositions of Ornstein–Uhlenbeck-type processes (OU), called supOU processes, provide a class of continuous time processes capable of exhibiting long memory behavior. This paper introduces multivariate supOU processes and gives conditions for their existence and finiteness of moments....... Moreover, the second-order moment structure is explicitly calculated, and examples exhibit the possibility of long-range dependence. Our supOU processes are defined via homogeneous and factorizable Lévy bases. We show that the behavior of supOU processes is particularly nice when the mean reversion...... parameter is restricted to normal matrices and especially to strictly negative definite ones. For finite variation Lévy bases we are able to give conditions for supOU processes to have locally bounded càdlàg paths of finite variation and to show an analogue of the stochastic differential equation of OU...

  1. Rapid process development of chromatographic process using direct analysis in real time mass spectrometry as a process analytical technology tool.

    Science.gov (United States)

    Yan, Binjun; Chen, Teng; Xu, Zhilin; Qu, Haibin

    2014-06-01

    The concept of quality by design (QbD) is widely applied in the process development of pharmaceuticals. However, the additional cost and time have caused some resistance about QbD implementation. To show a possible solution, this work proposed a rapid process development method, which used direct analysis in real time mass spectrometry (DART-MS) as a process analytical technology (PAT) tool for studying the chromatographic process of Ginkgo biloba L., as an example. The breakthrough curves were fast determined by DART-MS at-line. A high correlation coefficient of 0.9520 was found between the concentrations of ginkgolide A determined by DART-MS and HPLC. Based on the PAT tool, the impacts of process parameters on the adsorption capacity were discovered rapidly, which showed a decreased adsorption capacity with the increase of the flow rate. This work has shown the feasibility and advantages of integrating PAT into QbD implementation for rapid process development. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Recollection is a continuous process: implications for dual-process theories of recognition memory.

    Science.gov (United States)

    Mickes, Laura; Wais, Peter E; Wixted, John T

    2009-04-01

    Dual-process theory, which holds that recognition decisions can be based on recollection or familiarity, has long seemed incompatible with signal detection theory, which holds that recognition decisions are based on a singular, continuous memory-strength variable. Formal dual-process models typically regard familiarity as a continuous process (i.e., familiarity comes in degrees), but they construe recollection as a categorical process (i.e., recollection either occurs or does not occur). A continuous process is characterized by a graded relationship between confidence and accuracy, whereas a categorical process is characterized by a binary relationship such that high confidence is associated with high accuracy but all lower degrees of confidence are associated with chance accuracy. Using a source-memory procedure, we found that the relationship between confidence and source-recollection accuracy was graded. Because recollection, like familiarity, is a continuous process, dual-process theory is more compatible with signal detection theory than previously thought.

  3. Fractional Poisson process (II)

    International Nuclear Information System (INIS)

    Wang Xiaotian; Wen Zhixiong; Zhang Shiying

    2006-01-01

    In this paper, we propose a stochastic process W H (t)(H-bar (12,1)) which we call fractional Poisson process. The process W H (t) is self-similar in wide sense, displays long range dependence, and has more fatter tail than Gaussian process. In addition, it converges to fractional Brownian motion in distribution

  4. Making process improvement 'stick'.

    Science.gov (United States)

    Studer, Quint

    2014-06-01

    To sustain gains from a process improvement initiative, healthcare organizations should: Explain to staff why a process improvement initiative is needed. Encourage leaders within the organization to champion the process improvement, and tie their evaluations to its outcomes. Ensure that both leaders and employees have the skills to help sustain the sought-after process improvements.

  5. Process Improvement Essentials

    CERN Document Server

    Persse, James R

    2006-01-01

    Process Improvement Essentials combines the foundation needed to understand process improvement theory with the best practices to help individuals implement process improvement initiatives in their organization. The three leading programs: ISO 9001:2000, CMMI, and Six Sigma--amidst the buzz and hype--tend to get lumped together under a common label. This book delivers a combined guide to all three programs, compares their applicability, and then sets the foundation for further exploration.

  6. Integrated Renovation Process

    DEFF Research Database (Denmark)

    Galiotto, Nicolas; Heiselberg, Per; Knudstrup, Mary-Ann

    2016-01-01

    renovation to be overcome. The homeowners were better integrated and their preferences and immaterial values were better taken into account. To keep the decision-making process economically viable and timely, the process as known today still needs to be improved, and new tools need to be developed....... This paper presents a new scheme: the integrated renovation process. One successful case study is introduced, and recommendations for future developments needed in the field are provided....

  7. Business Process Quality Computation : Computing Non-Functional Requirements to Improve Business Processes

    NARCIS (Netherlands)

    Heidari, F.

    2015-01-01

    Business process modelling is an important part of system design. When designing or redesigning a business process, stakeholders specify, negotiate, and agree on business requirements to be satisfied, including non-functional requirements that concern the quality of the business process. This thesis

  8. Specification of e-business process model for PayPal online payment process using Reo

    NARCIS (Netherlands)

    M. Xie

    2005-01-01

    textabstractE-business process modeling allows business analysts to better understand and analyze the business processes, and eventually to use software systems to automate (parts of) these business processes to achieve higher profit. To support e-business process modeling, many business process

  9. Honing process optimization algorithms

    Science.gov (United States)

    Kadyrov, Ramil R.; Charikov, Pavel N.; Pryanichnikova, Valeria V.

    2018-03-01

    This article considers the relevance of honing processes for creating high-quality mechanical engineering products. The features of the honing process are revealed and such important concepts as the task for optimization of honing operations, the optimal structure of the honing working cycles, stepped and stepless honing cycles, simulation of processing and its purpose are emphasized. It is noted that the reliability of the mathematical model determines the quality parameters of the honing process control. An algorithm for continuous control of the honing process is proposed. The process model reliably describes the machining of a workpiece in a sufficiently wide area and can be used to operate the CNC machine CC743.

  10. Sustainable process synthesis–intensification

    DEFF Research Database (Denmark)

    Babi, Deenesh Kavi; Holtbruegge, Johannes; Lutze, Philip

    2015-01-01

    Chemical industry is facing global challenges such as the need to find sustainable production processes.Process intensification as part of process synthesis has the potential to find truly innovative and moresustainable solutions. In this paper, a computer-aided, multi-level, multi-scale framework...... for synthesis,design and intensification of processes, for identifying more sustainable alternatives is presented. Withinthe framework, a three stage work-flow has been implemented where, in the first “synthesis” stage anoptimal processing route is synthesized through a network superstructure optimization...

  11. Data processing made simple

    CERN Document Server

    Wooldridge, Susan

    2013-01-01

    Data Processing: Made Simple, Second Edition presents discussions of a number of trends and developments in the world of commercial data processing. The book covers the rapid growth of micro- and mini-computers for both home and office use; word processing and the 'automated office'; the advent of distributed data processing; and the continued growth of database-oriented systems. The text also discusses modern digital computers; fundamental computer concepts; information and data processing requirements of commercial organizations; and the historical perspective of the computer industry. The

  12. Participative Facility Planning for Obstetrical and Neonatal Care Processes: Beginning of Life Process

    Directory of Open Access Journals (Sweden)

    Jori Reijula

    2016-01-01

    Full Text Available Introduction. Old hospitals may promote inefficient patient care processes and safety. A new, functionally planned hospital presents a chance to create an environment that supports streamlined, patient-centered healthcare processes and adapts to users’ needs. This study depicts the phases of a facility planning project for pregnant women and newborn care processes (beginning of life process at Turku University Hospital. Materials and Methods. Project design reports and meeting documents were utilized to assess the beginning of life process as well as the work processes of the Women’s and Children’s Hospital. Results. The main elements of the facility design (FD project included rigorous preparation for the FD phase, functional planning throughout the FD process, and setting key values: (1 family-centered care, (2 Lean thinking and Lean tools as the framework for the FD process, (3 safety, and (4 cooperation. Conclusions. A well-prepared FD project with sufficient insight into functional planning, Lean thinking, and user-centricity seemed to facilitate the actual FD process. Although challenges occurred, the key values were not forgone and were successfully incorporated into the new hospital building.

  13. Signals, processes, and systems an interactive multimedia introduction to signal processing

    CERN Document Server

    Karrenberg, Ulrich

    2013-01-01

    This is a very new concept for learning Signal Processing, not only from the physically-based scientific fundamentals, but also from the didactic perspective, based on modern results of brain research. The textbook together with the DVD form a learning system that provides investigative studies and enables the reader to interactively visualize even complex processes. The unique didactic concept is built on visualizing signals and processes on the one hand, and on graphical programming of signal processing systems on the other. The concept has been designed especially for microelectronics, computer technology and communication. The book allows to develop, modify, and optimize useful applications using DasyLab - a professional and globally supported software for metrology and control engineering. With the 3rd edition, the software is also suitable for 64 bit systems running on Windows 7. Real signals can be acquired, processed and played on the sound card of your computer. The book provides more than 200 pre-pr...

  14. Modular toolkit for Data Processing (MDP: a Python data processing framework

    Directory of Open Access Journals (Sweden)

    Tiziano Zito

    2009-01-01

    Full Text Available Modular toolkit for Data Processing (MDP is a data processing framework written in Python. From the user's perspective, MDP is a collection of supervised and unsupervised learning algorithms and other data processing units that can be combined into data processing sequences and more complex feed-forward network architectures. Computations are performed efficiently in terms of speed and memory requirements. From the scientific developer's perspective, MDP is a modular framework, which can easily be expanded. The implementation of new algorithms is easy and intuitive. The new implemented units are then automatically integrated with the rest of the library. MDP has been written in the context of theoretical research in neuroscience, but it has been designed to be helpful in any context where trainable data processing algorithms are used. Its simplicity on the user's side, the variety of readily available algorithms, and the reusability of the implemented units make it also a useful educational tool.

  15. ARTIST process. A novel chemical process for treatment of spent nuclear fuel

    International Nuclear Information System (INIS)

    Tachimori, Shoichi

    2001-10-01

    A new chemical process, ARTIST process, is proposed for the treatment of spent nuclear fuel. The main concept of the ARTIST process is to recover and stock all actinides (Ans) as two groups, uranium (U) and a mixture of transuranics (TRU), to preserve their resource value and to dispose solely fission products (FPs). The process is composed of two main steps, an U exclusive isolation and a total recovery of TRU; which copes with the nuclear non-proliferation measures, and additionally of Pu separation process and soft N-donor process if requested, and optionally of processes for separation of long-lived FPs. These An products: U-product and TRU-product, are to be solidified by calcination and allowed to the interim stockpile for future utilization. These separations are achieved by use of amidic extractants in accord with the CHON principle. The technical feasibility of the ARTIST process was explained by the performance of both the branched alkyl monoamides in extracting U and suppressing the extraction of tetravalent Ans due to the steric effect and the diglycolic amide (TODGA) in thorough extraction of all TRU by tridentate fashion. When these TRU are requested to put into reactors, LWR or FBR, for power generation or the Accelerator - Driven System (ADS) for transmutation, Pu (Np) or Am-Cm (Np) are to be extracted from the TRU-product. (author)

  16. Exploiting process cubes, analytic workflows and process mining for business process reporting : a case study in education

    NARCIS (Netherlands)

    Bolt Iriondo, Alfredo; de Leoni, Massimiliano; van der Aalst, Wil M.P.; Gorissen, Pierre; Ceravolo, P.; Rinderle-Ma, S.

    2015-01-01

    Business Process Intelligence (BPI) is an emerging topic that has gained popularity in the last decade. It is driven by the need for analysis techniques that allow businesses to understand and improve their processes. One of the most common applications of BPI is reporting, which consists on the

  17. On Intelligent Design and Planning Method of Process Route Based on Gun Breech Machining Process

    Science.gov (United States)

    Hongzhi, Zhao; Jian, Zhang

    2018-03-01

    The paper states an approach of intelligent design and planning of process route based on gun breech machining process, against several problems, such as complex machining process of gun breech, tedious route design and long period of its traditional unmanageable process route. Based on gun breech machining process, intelligent design and planning system of process route are developed by virtue of DEST and VC++. The system includes two functional modules--process route intelligent design and its planning. The process route intelligent design module, through the analysis of gun breech machining process, summarizes breech process knowledge so as to complete the design of knowledge base and inference engine. And then gun breech process route intelligently output. On the basis of intelligent route design module, the final process route is made, edited and managed in the process route planning module.

  18. A systematic synthesis and design methodology to achieve process intensification in (bio) chemical processes

    DEFF Research Database (Denmark)

    Lutze, Philip; Roman Martinez, Alicia; Woodley, John

    2012-01-01

    Process intensification (PI) has the potential to improve existing processes or create new process options, which are needed in order to produce products using more sustainable methods. In principle, an enormous number of process options can be generated but where and how the process should be in...

  19. Process Mining Methodology for Health Process Tracking Using Real-Time Indoor Location Systems

    Science.gov (United States)

    Fernandez-Llatas, Carlos; Lizondo, Aroa; Monton, Eduardo; Benedi, Jose-Miguel; Traver, Vicente

    2015-01-01

    The definition of efficient and accurate health processes in hospitals is crucial for ensuring an adequate quality of service. Knowing and improving the behavior of the surgical processes in a hospital can improve the number of patients that can be operated on using the same resources. However, the measure of this process is usually made in an obtrusive way, forcing nurses to get information and time data, affecting the proper process and generating inaccurate data due to human errors during the stressful journey of health staff in the operating theater. The use of indoor location systems can take time information about the process in an unobtrusive way, freeing nurses, allowing them to engage in purely welfare work. However, it is necessary to present these data in a understandable way for health professionals, who cannot deal with large amounts of historical localization log data. The use of process mining techniques can deal with this problem, offering an easily understandable view of the process. In this paper, we present a tool and a process mining-based methodology that, using indoor location systems, enables health staff not only to represent the process, but to know precise information about the deployment of the process in an unobtrusive and transparent way. We have successfully tested this tool in a real surgical area with 3613 patients during February, March and April of 2015. PMID:26633395

  20. Process Mining Methodology for Health Process Tracking Using Real-Time Indoor Location Systems.

    Science.gov (United States)

    Fernandez-Llatas, Carlos; Lizondo, Aroa; Monton, Eduardo; Benedi, Jose-Miguel; Traver, Vicente

    2015-11-30

    The definition of efficient and accurate health processes in hospitals is crucial for ensuring an adequate quality of service. Knowing and improving the behavior of the surgical processes in a hospital can improve the number of patients that can be operated on using the same resources. However, the measure of this process is usually made in an obtrusive way, forcing nurses to get information and time data, affecting the proper process and generating inaccurate data due to human errors during the stressful journey of health staff in the operating theater. The use of indoor location systems can take time information about the process in an unobtrusive way, freeing nurses, allowing them to engage in purely welfare work. However, it is necessary to present these data in a understandable way for health professionals, who cannot deal with large amounts of historical localization log data. The use of process mining techniques can deal with this problem, offering an easily understandable view of the process. In this paper, we present a tool and a process mining-based methodology that, using indoor location systems, enables health staff not only to represent the process, but to know precise information about the deployment of the process in an unobtrusive and transparent way. We have successfully tested this tool in a real surgical area with 3613 patients during February, March and April of 2015.

  1. Discovering Process Reference Models from Process Variants Using Clustering Techniques

    NARCIS (Netherlands)

    Li, C.; Reichert, M.U.; Wombacher, Andreas

    2008-01-01

    In today's dynamic business world, success of an enterprise increasingly depends on its ability to react to changes in a quick and flexible way. In response to this need, process-aware information systems (PAIS) emerged, which support the modeling, orchestration and monitoring of business processes

  2. Thin film processes II

    CERN Document Server

    Kern, Werner

    1991-01-01

    This sequel to the 1978 classic, Thin Film Processes, gives a clear, practical exposition of important thin film deposition and etching processes that have not yet been adequately reviewed. It discusses selected processes in tutorial overviews with implementation guide lines and an introduction to the literature. Though edited to stand alone, when taken together, Thin Film Processes II and its predecessor present a thorough grounding in modern thin film techniques.Key Features* Provides an all-new sequel to the 1978 classic, Thin Film Processes* Introduces new topics, and sever

  3. Business process transformation

    CERN Document Server

    Grover, Varun

    2015-01-01

    Featuring contributions from prominent thinkers and researchers, this volume in the ""Advances in Management Information Systems"" series provides a rich set of conceptual, empirical, and introspective studies that epitomize fundamental knowledge in the area of Business Process Transformation. Processes are interpreted broadly to include operational and managerial processes within and between organizations, as well as those involved in knowledge generation. Transformation includes radical and incremental change, its conduct, management, and outcome. The editors and contributing authors pay clo

  4. Shell coal gasification process

    Energy Technology Data Exchange (ETDEWEB)

    Hennekes, B. [Shell Global Solutions (US) Inc. (United States). Technology Marketing

    2002-07-01

    The presentation, on which 17 slides/overheads are included in the papers, explained the principles of the Shell coal gasification process and the methods incorporated for control of sulfur dioxide, nitrogen oxides, particulates and mercury. The economics of the process were discussed. The differences between gasification and burning, and the differences between the Shell process and other processes were discussed.

  5. Closed-Loop Process Control for Electron Beam Freeform Fabrication and Deposition Processes

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hafley, Robert A. (Inventor); Martin, Richard E. (Inventor); Hofmeister, William H. (Inventor)

    2013-01-01

    A closed-loop control method for an electron beam freeform fabrication (EBF(sup 3)) process includes detecting a feature of interest during the process using a sensor(s), continuously evaluating the feature of interest to determine, in real time, a change occurring therein, and automatically modifying control parameters to control the EBF(sup 3) process. An apparatus provides closed-loop control method of the process, and includes an electron gun for generating an electron beam, a wire feeder for feeding a wire toward a substrate, wherein the wire is melted and progressively deposited in layers onto the substrate, a sensor(s), and a host machine. The sensor(s) measure the feature of interest during the process, and the host machine continuously evaluates the feature of interest to determine, in real time, a change occurring therein. The host machine automatically modifies control parameters to the EBF(sup 3) apparatus to control the EBF(sup 3) process in a closed-loop manner.

  6. Issues Management Process Course # 38401

    Energy Technology Data Exchange (ETDEWEB)

    Binion, Ula Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-02-01

    The purpose of this training it to advise Issues Management Coordinators (IMCs) on the revised Contractor Assurance System (CAS) Issues Management (IM) process. Terminal Objectives: Understand the Laboratory’s IM process; Understand your role in the Laboratory’s IM process. Learning Objectives: Describe the IM process within the context of the CAS; Describe the importance of implementing an institutional IM process at LANL; Describe the process flow for the Laboratory’s IM process; Apply the definition of an issue; Use available resources to determine initial screening risk levels for issues; Describe the required major process steps for each risk level; Describe the personnel responsibilities for IM process implementation; Access available resources to support IM process implementation.

  7. Organizing Process

    DEFF Research Database (Denmark)

    Hull Kristensen, Peer; Bojesen, Anders

    This paper invites to discuss the processes of individualization and organizing being carried out under what we might see as an emerging regime of change. The underlying argumentation is that in certain processes of change, competence becomes questionable at all times. The hazy characteristics...... of this regime of change are pursued through a discussion of competencies as opposed to qualifications illustrated by distinct cases from the Danish public sector in the search for repetitive mechanisms. The cases are put into a general perspective by drawing upon experiences from similar change processes...... in MNCs. The paper concludes by asking whether we can escape from a regime of competence in a world defined by a rhetoric of change and create a more promising world in which doubt and search serve as a strategy for gaining knowledge and professionalism that improve on our capability for mutualism....

  8. The SILVA atomic process

    International Nuclear Information System (INIS)

    Cazalet, J.

    1997-01-01

    The SILVA laser isotope separation process is based on the laser selective photo-ionization of uranium atomic vapour; the process is presently under development by CEA and COGEMA in France, with the aim to reduce by a factor three the cost of uranium enrichment. The two main components of a SILVA process plant are the lasers (copper vapour lasers and dye lasers) and the separator for the vaporization (with a high energy electron beam), ionization and separation operations. Researches on the SILVA process started in 1985 and the technical and economical feasibility is to be demonstrated in 1997. The progresses of similar rival processes and other processes are discussed and the remaining research stages and themes of the SILVA program are presented

  9. Badge Office Process Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Haurykiewicz, John Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dinehart, Timothy Grant [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Parker, Robert Young [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-12

    The purpose of this process analysis was to analyze the Badge Offices’ current processes from a systems perspective and consider ways of pursuing objectives set forth by SEC-PS, namely increased customer flow (throughput) and reduced customer wait times. Information for the analysis was gathered for the project primarily through Badge Office Subject Matter Experts (SMEs), and in-person observation of prevailing processes. Using the information gathered, a process simulation model was constructed to represent current operations and allow assessment of potential process changes relative to factors mentioned previously. The overall purpose of the analysis was to provide SEC-PS management with information and recommendations to serve as a basis for additional focused study and areas for potential process improvements in the future.

  10. Water And Waste Water Processing

    International Nuclear Information System (INIS)

    Yang, Byeong Ju

    1988-04-01

    This book shows US the distribution diagram of water and waste water processing with device of water processing, and device of waste water processing, property of water quality like measurement of pollution of waste water, theoretical Oxygen demand, and chemical Oxygen demand, processing speed like zero-order reactions and enzyme reactions, physical processing of water and waste water, chemical processing of water and waste water like neutralization and buffering effect, biological processing of waste water, ammonia removal, and sludges processing.

  11. Specification of e-business process model for PayPal online payment process using Reo

    OpenAIRE

    Xie, M.

    2005-01-01

    textabstractE-business process modeling allows business analysts to better understand and analyze the business processes, and eventually to use software systems to automate (parts of) these business processes to achieve higher profit. To support e-business process modeling, many business process modeling languages have been used as tools. However, many existing business process modeling languages lack (a) formal semantics, (b) formal computational model, and (c) an integrated view of the busi...

  12. Translating Message Sequence Charts to other Process Languages using Process

    DEFF Research Database (Denmark)

    Lassen, Kristian Bisgaard; van Dongen, Boudewijn F.

    2008-01-01

    stakeholders. Often such discussions lead to more complete behavioral models described by e.g. Event-driven Process Chains (EPCs), UML activity diagrams, BPMN models, Petri nets, etc. Process mining on the other hand, deals with the problem of constructing complete behavioral models by analyzing event logs...

  13. Pennsylvania's partnering process

    International Nuclear Information System (INIS)

    Latham, J.W.

    1996-01-01

    Pennsylvania is committed to finding a site for a low-level radioactive waste (LLRW) disposal facility through an innovative voluntary process. The Pennsylvania Department of Environmental Protection (DEP) and Chem-Nuclear Systems, Inc. (CNSI) developed the Community Partnering Plan with extensive public participation. The Community Partnering Plan outlines a voluntary process that empowers municipalities to evaluate the advantages and disadvantages of hosting the facility. DEP and CNSI began developing the Community Partnering Plan in July 1995. Before then, CNSI was using a screening process prescribed by state law and regulations to find a location for the facility. So far, approximately 78 percent of the Commonwealth has been identified as disqualified as a site for the LLRW disposal facility. The siting effort will now focus on identifying volunteer host municipalities in the remaining 22 percent of the state. This combination of technical screening and voluntary consideration makes Pennsylvania's process unique. A volunteered site will have to meet the same tough requirements for protecting people and the environment as a site chosen through the screening process. Protection of public health and safety continues to be the foundation of the state's siting efforts. The Community Partnering Plan offers a window of opportunity. If Pennsylvania does not find volunteer municipalities with suitable sites by the end of 1997, it probably will return to a technical screening process

  14. Raw material changes and their processing parameters in an extrusion cooking process

    DEFF Research Database (Denmark)

    Cheng, Hongyuan; Friis, Alan

    In this work, the effects of raw material and process parameters on product expansion in a fish feed extrusion process were investigated. Four different recipes were studied with a pilot-scale twin-screw co-rotating extruder according to a set of pre-defined processing conditions. In the four rec...

  15. Process monitoring for intelligent manufacturing processes - Methodology and application to Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas

    Process monitoring provides important information on the product, process and manufacturing system during part manufacturing. Such information can be used for process optimization and detection of undesired processing conditions to initiate timely actions for avoidance of defects, thereby improving...... quality assurance. This thesis is aimed at a systematic development of process monitoring solutions, constituting a key element of intelligent manufacturing systems towards zero defect manufacturing. A methodological approach of general applicability is presented in this concern.The approach consists...... of six consecutive steps for identification of product Vital Quality Characteristics (VQCs) and Key Process Variables (KPVs), selection and characterization of sensors, optimization of sensors placement, validation of the monitoring solutions, definition of the reference manufacturing performance...

  16. Laser dimpling process parameters selection and optimization using surrogate-driven process capability space

    Science.gov (United States)

    Ozkat, Erkan Caner; Franciosa, Pasquale; Ceglarek, Dariusz

    2017-08-01

    Remote laser welding technology offers opportunities for high production throughput at a competitive cost. However, the remote laser welding process of zinc-coated sheet metal parts in lap joint configuration poses a challenge due to the difference between the melting temperature of the steel (∼1500 °C) and the vapourizing temperature of the zinc (∼907 °C). In fact, the zinc layer at the faying surface is vapourized and the vapour might be trapped within the melting pool leading to weld defects. Various solutions have been proposed to overcome this problem over the years. Among them, laser dimpling has been adopted by manufacturers because of its flexibility and effectiveness along with its cost advantages. In essence, the dimple works as a spacer between the two sheets in lap joint and allows the zinc vapour escape during welding process, thereby preventing weld defects. However, there is a lack of comprehensive characterization of dimpling process for effective implementation in real manufacturing system taking into consideration inherent changes in variability of process parameters. This paper introduces a methodology to develop (i) surrogate model for dimpling process characterization considering multiple-inputs (i.e. key control characteristics) and multiple-outputs (i.e. key performance indicators) system by conducting physical experimentation and using multivariate adaptive regression splines; (ii) process capability space (Cp-Space) based on the developed surrogate model that allows the estimation of a desired process fallout rate in the case of violation of process requirements in the presence of stochastic variation; and, (iii) selection and optimization of the process parameters based on the process capability space. The proposed methodology provides a unique capability to: (i) simulate the effect of process variation as generated by manufacturing process; (ii) model quality requirements with multiple and coupled quality requirements; and (iii

  17. Contaminated nickel scrap processing

    International Nuclear Information System (INIS)

    Compere, A.L.; Griffith, W.L.; Hayden, H.W.; Johnson, J.S. Jr.; Wilson, D.F.

    1994-12-01

    The DOE will soon choose between treating contaminated nickel scrap as a legacy waste and developing high-volume nickel decontamination processes. In addition to reducing the volume of legacy wastes, a decontamination process could make 200,000 tons of this strategic metal available for domestic use. Contaminants in DOE nickel scrap include 234 Th, 234 Pa, 137 Cs, 239 Pu (trace), 60 Co, U, 99 Tc, and 237 Np (trace). This report reviews several industrial-scale processes -- electrorefining, electrowinning, vapormetallurgy, and leaching -- used for the purification of nickel. Conventional nickel electrolysis processes are particularly attractive because they use side-stream purification of process solutions to improve the purity of nickel metal. Additionally, nickel purification by electrolysis is effective in a variety of electrolyte systems, including sulfate, chloride, and nitrate. Conventional electrorefining processes typically use a mixed electrolyte which includes sulfate, chloride, and borate. The use of an electrorefining or electrowinning system for scrap nickel recovery could be combined effectively with a variety of processes, including cementation, solvent extraction, ion exchange, complex-formation, and surface sorption, developed for uranium and transuranic purification. Selected processes were reviewed and evaluated for use in nickel side-stream purification. 80 refs

  18. Wetland Groundwater Processes

    National Research Council Canada - National Science Library

    Williams, Greg

    1993-01-01

    This technical note summarizes hydrologic and hydraulic (H AND H) processes and the related terminology that will likely be encountered during an evaluation of the effect of ground-water processes on wetland function...

  19. Manufacturing Process Selection of Composite Bicycle’s Crank Arm using Analytical Hierarchy Process (AHP)

    Science.gov (United States)

    Luqman, M.; Rosli, M. U.; Khor, C. Y.; Zambree, Shayfull; Jahidi, H.

    2018-03-01

    Crank arm is one of the important parts in a bicycle that is an expensive product due to the high cost of material and production process. This research is aimed to investigate the potential type of manufacturing process to fabricate composite bicycle crank arm and to describe an approach based on analytical hierarchy process (AHP) that assists decision makers or manufacturing engineers in determining the most suitable process to be employed in manufacturing of composite bicycle crank arm at the early stage of the product development process to reduce the production cost. There are four types of processes were considered, namely resin transfer molding (RTM), compression molding (CM), vacuum bag molding and filament winding (FW). The analysis ranks these four types of process for its suitability in the manufacturing of bicycle crank arm based on five main selection factors and 10 sub factors. Determining the right manufacturing process was performed based on AHP process steps. Consistency test was performed to make sure the judgements are consistent during the comparison. The results indicated that the compression molding was the most appropriate manufacturing process because it has the highest value (33.6%) among the other manufacturing processes.

  20. Advanced materials processing

    International Nuclear Information System (INIS)

    Giamei, A.F.

    1993-01-01

    Advanced materials will require improved processing methods due to high melting points, low toughness or ductility values, high reactivity with air or ceramics and typically complex crystal structures with significant anisotropy in flow and/or fracture stress. Materials for structural applications at elevated temperature in critical systems will require processing with a high degree of control. This requires an improved understanding of the relationship between process variables and microstructure to enable control systems to achieve consistently high quality. One avenue to the required level of understanding is computer simulation. Past attempts to do process modeling have been hampered by incomplete data regarding thermophysical or mechanical material behavior. Some of the required data can be calculated. Due to the advances in software and hardware, accuracy and costs are in the realm of acquiring experimental data. Such calculations can, for example, be done at an atomic level to compute lattice energy, fault energies, density of states and charge densities. These can lead to fundamental information about the competition between slip and fracture, anisotropy of bond strength (and therefore cleavage strength), cohesive strength, adhesive strength, elastic modulus, thermal expansion and possibly other quantities which are difficult (and therefore expensive to measure). Some of these quantities can be fed into a process model. It is probable that temperature dependencies can be derived numerically as well. Examples are given of the beginnings of such an approach for Ni 3 Al and MoSi 2 . Solidification problems are examples of the state-of-the-art process modeling and adequately demonstrate the need for extensive input data. Such processes can be monitored in terms of interfacial position vs. time, cooling rate and thermal gradient

  1. Optimization of a novel enzyme treatment process for early-stage processing of sheepskins.

    Science.gov (United States)

    Lim, Y F; Bronlund, J E; Allsop, T F; Shilton, A N; Edmonds, R L

    2010-01-01

    An enzyme treatment process for early-stage processing of sheepskins has been previously reported by the Leather and Shoe Research Association of New Zealand (LASRA) as an alternative to current industry operations. The newly developed process had marked benefits over conventional processing in terms of a lowered energy usage (73%), processing time (47%) as well as water use (49%), but had been developed as a "proof of principle''. The objective of this work was to develop the process further to a stage ready for adoption by industry. Mass balancing was used to investigate potential modifications for the process based on the understanding developed from a detailed analysis of preliminary design trials. Results showed that a configuration utilising a 2 stage counter-current system for the washing stages and segregation and recycling of enzyme float prior to dilution in the neutralization stage was a significant improvement. Benefits over conventional processing include a reduction of residual TDS by 50% at the washing stages and 70% savings on water use overall. Benefits over the un-optimized LASRA process are reduction of solids in product after enzyme treatment and neutralization stages by 30%, additional water savings of 21%, as well as 10% savings of enzyme usage.

  2. Rational Unified Process

    OpenAIRE

    Kopal, Nils

    2016-01-01

    In this German seminar paper, which was written in the year 2011 at the University of Duisburg for a Bachelor Colloquium in Applied computer science, we show a brief overview of the Rational Unified Process (RUP). Thus, interested students or generally interested people in software development gain a first impression of RUP. The paper includes a survey and overview of the underlying process structure, the phases of the process, its workflows, and describes the always by the RUP developers pos...

  3. gProcess and ESIP Platforms for Satellite Imagery Processing over the Grid

    Science.gov (United States)

    Bacu, Victor; Gorgan, Dorian; Rodila, Denisa; Pop, Florin; Neagu, Gabriel; Petcu, Dana

    2010-05-01

    The Environment oriented Satellite Data Processing Platform (ESIP) is developed through the SEE-GRID-SCI (SEE-GRID eInfrastructure for regional eScience) co-funded by the European Commission through FP7 [1]. The gProcess Platform [2] is a set of tools and services supporting the development and the execution over the Grid of the workflow based processing, and particularly the satelite imagery processing. The ESIP [3], [4] is build on top of the gProcess platform by adding a set of satellite image processing software modules and meteorological algorithms. The satellite images can reveal and supply important information on earth surface parameters, climate data, pollution level, weather conditions that can be used in different research areas. Generally, the processing algorithms of the satellite images can be decomposed in a set of modules that forms a graph representation of the processing workflow. Two types of workflows can be defined in the gProcess platform: abstract workflow (PDG - Process Description Graph), in which the user defines conceptually the algorithm, and instantiated workflow (iPDG - instantiated PDG), which is the mapping of the PDG pattern on particular satellite image and meteorological data [5]. The gProcess platform allows the definition of complex workflows by combining data resources, operators, services and sub-graphs. The gProcess platform is developed for the gLite middleware that is available in EGEE and SEE-GRID infrastructures [6]. gProcess exposes the specific functionality through web services [7]. The Editor Web Service retrieves information on available resources that are used to develop complex workflows (available operators, sub-graphs, services, supported resources, etc.). The Manager Web Service deals with resources management (uploading new resources such as workflows, operators, services, data, etc.) and in addition retrieves information on workflows. The Executor Web Service manages the execution of the instantiated workflows

  4. Business Process Inventory

    Data.gov (United States)

    Office of Personnel Management — Inventory of maps and descriptions of the business processes of the U.S. Office of Personnel Management (OPM), with an emphasis on the processes of the Office of the...

  5. Eye Tracking Meets the Process of Process Modeling: a Visual Analytic Approach

    DEFF Research Database (Denmark)

    Burattin, Andrea; Kaiser, M.; Neurauter, Manuel

    2017-01-01

    Research on the process of process modeling (PPM) studies how process models are created. It typically uses the logs of the interactions with the modeling tool to assess the modeler’s behavior. In this paper we suggest to introduce an additional stream of data (i.e., eye tracking) to improve the ...

  6. Empirical evaluation of the Process Overview Measure for assessing situation awareness in process plants.

    Science.gov (United States)

    Lau, Nathan; Jamieson, Greg A; Skraaning, Gyrd

    2016-03-01

    The Process Overview Measure is a query-based measure developed to assess operator situation awareness (SA) from monitoring process plants. A companion paper describes how the measure has been developed according to process plant properties and operator cognitive work. The Process Overview Measure demonstrated practicality, sensitivity, validity and reliability in two full-scope simulator experiments investigating dramatically different operational concepts. Practicality was assessed based on qualitative feedback of participants and researchers. The Process Overview Measure demonstrated sensitivity and validity by revealing significant effects of experimental manipulations that corroborated with other empirical results. The measure also demonstrated adequate inter-rater reliability and practicality for measuring SA in full-scope simulator settings based on data collected on process experts. Thus, full-scope simulator studies can employ the Process Overview Measure to reveal the impact of new control room technology and operational concepts on monitoring process plants. Practitioner Summary: The Process Overview Measure is a query-based measure that demonstrated practicality, sensitivity, validity and reliability for assessing operator situation awareness (SA) from monitoring process plants in representative settings.

  7. Technology or Process First?

    DEFF Research Database (Denmark)

    Siurdyban, Artur Henryk; Svejvig, Per; Møller, Charles

    Enterprise Systems Management (ESM) and Business Pro- cess Management (BPM), although highly correlated, have evolved as alternative and mutually exclusive approaches to corporate infrastruc- ture. As a result, companies struggle to nd the right balance between technology and process factors...... in infrastructure implementation projects. The purpose of this paper is articulate a need and a direction to medi- ate between the process-driven and the technology-driven approaches. Using a cross-case analysis, we gain insight into two examples of sys- tems and process implementation. We highlight the dierences...... between them using strategic alignment, Enterprise Systems and Business Process Management theories. We argue that the insights from these cases can lead to a better alignment between process and technology. Implications for practice include the direction towards a closer integration of process...

  8. Sustainable Process Synthesis-Intensification

    DEFF Research Database (Denmark)

    Babi, Deenesh Kavi

    The chemical and biochemical industry needs major reductions in energy consumption, waste generation, number of equipment used in the construction of plants and capital/operational cost. These required reductions can be addressed through process intensification that is the efficient use of raw....... Therefore sustainable process design can be achieved by performing process syn-thesis and process intensification together. The main contribution of this work is the development of a systematic computer-aided multi-scale, multi-level framework for performing process synthesis-intensification that aims...... designs that otherwise could not be found from the higher scales. The framework is applied to three case studies related to the chemical and bioprocess industry in order to test the applicability of the framework for covering a wide range of applications, showing that process intensification provides...

  9. Remarks to a process-overlapping description of cost structures of energy conversion processes

    International Nuclear Information System (INIS)

    Barnert, H.

    1986-03-01

    The cost of energy conversion processes are more and more determined by capital expenses. These are partly used to improve the efficiency. With a mathematical formula for the relation between capital costs and efficiency a process-over-laping description is proposed and proved at 10 typically chosen energy conversion processes. The result is a classification of enery conversion processes in categories of efficiency-producing and efficiency-independent capital expenditures. Another result is that process-overlapping the relative capital cost supplement is described by the (1-eta)/eta-law. (orig.) [de

  10. Renewal processes

    CERN Document Server

    Mitov, Kosto V

    2014-01-01

    This monograph serves as an introductory text to classical renewal theory and some of its applications for graduate students and researchers in mathematics and probability theory. Renewal processes play an important part in modeling many phenomena in insurance, finance, queuing systems, inventory control and other areas. In this book, an overview of univariate renewal theory is given and renewal processes in the non-lattice and lattice case are discussed. A pre-requisite is a basic knowledge of probability theory.

  11. Transnational Learning Processes

    DEFF Research Database (Denmark)

    Nedergaard, Peter

    This paper analyses and compares the transnational learning processes in the employment field in the European Union and among the Nordic countries. Based theoretically on a social constructivist model of learning and methodologically on a questionnaire distributed to the relevant participants......, a number of hypotheses concerning transnational learning processes are tested. The paper closes with a number of suggestions regarding an optimal institutional setting for facilitating transnational learning processes.Key words: Transnational learning, Open Method of Coordination, Learning, Employment......, European Employment Strategy, European Union, Nordic countries....

  12. Software Process Validation: Quantitatively Measuring the Correspondence of a Process to a Model

    National Research Council Canada - National Science Library

    Cook, Jonathan E; Wolf, Alexander L

    1997-01-01

    .... When process models and process executions diverge, something significant is happening. The authors have developed techniques for uncovering and measuring the discrepancies between models and executions, which they call process validation...

  13. A computer-aided approach for achieving sustainable process design by process intensification

    DEFF Research Database (Denmark)

    Anantasarn, Nateetorn; Suriyapraphadilok, Uthaiporn; Babi, Deenesh Kavi

    2017-01-01

    to generate flowsheet alternatives that satisfy the design targets thereby, minimizing and/or eliminating the process hot-spots. The application of the framework is highlighted through the production of para-xylene via toluene methylation where more sustainable flowsheet alternatives that consist of hybrid......Process intensification can be applied to achieve sustainable process design. In this paper, a systematic, 3-stage synthesis-intensification framework is applied to achieve more sustainable design. In stage 1, the synthesis stage, an objective function and design constraints are defined and a base...... case is synthesized. In stage 2, the design and analysis stage, the base case is analyzed using economic and environmental analyses to identify process hot-spots that are translated into design targets. In stage 3, the innovation design stage, phenomena-based process intensification is performed...

  14. Investigation of the Effects of Continuous Low-Dose Epidural Analgesia on the Autonomic Nervous System Using Hilbert Huang Transform

    Directory of Open Access Journals (Sweden)

    Wei-Ren Chuang

    2010-01-01

    Full Text Available Effects of continuous low-dose epidural bupivacaine (0.05-0.1% infusion on the Doppler velocimetry for labor analgesia have been well documented. The aim of this study was to monitor the activity of the autonomic nervous system (ANS for women in labor based on Hilbert Huang transform (HHT, which performs signal processing for nonlinear systems, such as human cardiac systems. Thirteen pregnant women were included in the experimental group for labor analgesia. They received continuous epidural bupivacaine 0.075% infusion. The normal-to-normal intervals (NN-interval were downloaded from an ECG holter. Another 20 pregnant women in non-anesthesia labor (average gestation age was 38.6 weeks were included in the comparison group. In this study, HHT was used to decompose components of ECG signals, which reflect three different frequency bands of a person's heart rate spectrum (viz. high frequency (HF, low frequency (LF and very low frequency (VLF. It was found that the change of energy in subjects without anesthesia was more active than that with continuous epidural bupivacaine 0.075% infusion. The energy values of the experimental group (i.e., labor analgesia of HF and LF of ANS activities were significantly lower (P < 0.05 than the values of the comparison group (viz. labor without analgesia, but the trend of energy ratio of LF/HF was opposite. In conclusion, the sympathetic and parasympathetic components of ANS are all suppressed by continuous low-dose epidural bupivacaine 0.075% infusion, but parasympathetic power is suppressed more than sympathetic power.

  15. Immediate effects of reiki on heart rate variability, cortisol levels, and body temperature in health care professionals with burnout.

    Science.gov (United States)

    Díaz-Rodríguez, Lourdes; Arroyo-Morales, Manuel; Fernández-de-las-Peñas, Cesar; García-Lafuente, Francisca; García-Royo, Carmen; Tomás-Rojas, Inmaculada

    2011-10-01

    Burnout is a work-related mental health impairment comprising three dimensions: emotional exhaustion, depersonalization, and reduced personal accomplishment. Reiki aims to help replenish and rebalance the body's energetic system, thus stimulating the healing process. The objective of this placebo-controlled, repeated measures, crossover, single-blind, randomized trial was to analyze the immediate effects of Reiki on heart rate variability (HRV), body temperature, and salivary flow rate and cortisol level in health care professionals with burnout syndrome (BS). Participants included 21 health care professionals with BS, who were asked to complete two visits to the laboratory with a 1-week interval between sessions. They were randomly assigned the order in which they would receive a Reiki session applied by an experienced therapist and a placebo treatment applied by a therapist with no knowledge of Reiki, who mimicked the Reiki treatment. Temperature, Holter ECG recordings (standard deviation of the normal-to-normal interval [SDNN], square root of mean squared differences of successive NN intervals [RMSSD], HRV index, low frequency component [LF], and high frequency component [HF]), salivary flow rate and cortisol levels were measured at baseline and postintervention by an assessor blinded to allocation group. SDNN and body temperature were significantly higher after the Reiki treatment than after the placebo. LF was significantly lower after the Reiki treatment. The decrease in the LF domain was associated with the increase in body temperature. These results suggest that Reiki has an effect on the parasympathetic nervous system when applied to health care professionals with BS.

  16. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    Science.gov (United States)

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  17. Laser material processing

    CERN Document Server

    Steen, William

    2010-01-01

    This text moves from the basics of laser physics to detailed treatments of all major materials processing techniques for which lasers are now essential. New chapters cover laser physics, drilling, micro- and nanomanufacturing and biomedical laser processing.

  18. Cascading activation from lexical processing to letter-level processing in written word production.

    Science.gov (United States)

    Buchwald, Adam; Falconer, Carolyn

    2014-01-01

    Descriptions of language production have identified processes involved in producing language and the presence and type of interaction among those processes. In the case of spoken language production, consensus has emerged that there is interaction among lexical selection processes and phoneme-level processing. This issue has received less attention in written language production. In this paper, we present a novel analysis of the writing-to-dictation performance of an individual with acquired dysgraphia revealing cascading activation from lexical processing to letter-level processing. The individual produced frequent lexical-semantic errors (e.g., chipmunk → SQUIRREL) as well as letter errors (e.g., inhibit → INBHITI) and had a profile consistent with impairment affecting both lexical processing and letter-level processing. The presence of cascading activation is suggested by lower letter accuracy on words that are more weakly activated during lexical selection than on those that are more strongly activated. We operationalize weakly activated lexemes as those lexemes that are produced as lexical-semantic errors (e.g., lethal in deadly → LETAHL) compared to strongly activated lexemes where the intended target word (e.g., lethal) is the lexeme selected for production.

  19. Explicit and Implicit Processes Constitute the Fast and Slow Processes of Sensorimotor Learning.

    Science.gov (United States)

    McDougle, Samuel D; Bond, Krista M; Taylor, Jordan A

    2015-07-01

    A popular model of human sensorimotor learning suggests that a fast process and a slow process work in parallel to produce the canonical learning curve (Smith et al., 2006). Recent evidence supports the subdivision of sensorimotor learning into explicit and implicit processes that simultaneously subserve task performance (Taylor et al., 2014). We set out to test whether these two accounts of learning processes are homologous. Using a recently developed method to assay explicit and implicit learning directly in a sensorimotor task, along with a computational modeling analysis, we show that the fast process closely resembles explicit learning and the slow process approximates implicit learning. In addition, we provide evidence for a subdivision of the slow/implicit process into distinct manifestations of motor memory. We conclude that the two-state model of motor learning is a close approximation of sensorimotor learning, but it is unable to describe adequately the various implicit learning operations that forge the learning curve. Our results suggest that a wider net be cast in the search for the putative psychological mechanisms and neural substrates underlying the multiplicity of processes involved in motor learning. Copyright © 2015 the authors 0270-6474/15/359568-12$15.00/0.

  20. Contaminated nickel scrap processing

    Energy Technology Data Exchange (ETDEWEB)

    Compere, A.L.; Griffith, W.L.; Hayden, H.W.; Johnson, J.S. Jr.; Wilson, D.F.

    1994-12-01

    The DOE will soon choose between treating contaminated nickel scrap as a legacy waste and developing high-volume nickel decontamination processes. In addition to reducing the volume of legacy wastes, a decontamination process could make 200,000 tons of this strategic metal available for domestic use. Contaminants in DOE nickel scrap include {sup 234}Th, {sup 234}Pa, {sup 137}Cs, {sup 239}Pu (trace), {sup 60}Co, U, {sup 99}Tc, and {sup 237}Np (trace). This report reviews several industrial-scale processes -- electrorefining, electrowinning, vapormetallurgy, and leaching -- used for the purification of nickel. Conventional nickel electrolysis processes are particularly attractive because they use side-stream purification of process solutions to improve the purity of nickel metal. Additionally, nickel purification by electrolysis is effective in a variety of electrolyte systems, including sulfate, chloride, and nitrate. Conventional electrorefining processes typically use a mixed electrolyte which includes sulfate, chloride, and borate. The use of an electrorefining or electrowinning system for scrap nickel recovery could be combined effectively with a variety of processes, including cementation, solvent extraction, ion exchange, complex-formation, and surface sorption, developed for uranium and transuranic purification. Selected processes were reviewed and evaluated for use in nickel side-stream purification. 80 refs.