WorldWideScience
1

The role of Multidetector CT in the evaluation of the left atrium and pulmonary veins anatomy before and after radio-frequency catheter ablation for atrial fibrillation. Preliminary results and work in progress.Technical note  

International Nuclear Information System (INIS)

Radio-frequency catheter ablation (RFCA) of the distal pulmonary veins is increasingly being used to treat recurrent or refractory atrial fibrillation that doesn't respond to pharmacologic therapy or cardioversion. Successful RFCA of atrial al fibrillation depends on the pre-procedural understanding of the complex anatomy of the distal pulmonary veins and the left atrium. Aim of this parer is to describe the technical main features that characterise the multidetector helical computed tomography in the evaluation of this anatomic region before and after RFCA procedure. The 3D post-processing techniques useful for pre-RFCA planning are straightforward.

2

 

Medline Plus

... 2009) Arrhythmia Electrophysiological Study and Catheter Ablation with 3D Mapping (Mercy Hospital, Miami, FL, 11/15/2007) ...

3

Electrophysiological Study and Catheter Ablation with 3D Mapping  

Medline Plus

... see and electrophysiological study and catheter ablation with 3D mapping. During the procedure, doctors look at the ... perform a electrophysiology study with ablation, using our 3D mapping system. Keep in mind, that during the ...

4

Catheter Ablation for Paroxysmal Atrial Fibrillation  

Medline Plus

... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...

5

Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study  

Energy Technology Data Exchange (ETDEWEB)

To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant ...

2003-06-01

6

Cardiovascular magnetic resonance guided electrophysiology studies  

UK PubMed Central (United Kingdom)

Catheter ablation is a first line treatment for many cardiac arrhythmias and is generally performed under x-ray fluoroscopy guidance. However, current techniques for ablating complex arrhythmias such...Full Text Available

7

Properties of ZnO thin films prepared by radio-frequency plasma beam assisted laser ablation  

International Nuclear Information System (INIS)

Zinc oxide thin films were obtained by laser ablation of a Zn target in oxygen reactive atmosphere, the oxygen being supplied either by a standard gas inlet valve or from a radio-frequency (rf) oxygen plasma. Pt-coated silicon and MgO were used as substrates. The influence of the deposition parameters as laser wavelength (266, 355, 1064 nm), laser fluence (1.5-20 J/cm2) and oxygen pressure (1-60 Pa) was studied. The influence of the rf plasma beam addition on the morphological proprieties of zinc oxide films was particularly investigated, simultaneously with several configurations of the direction of the ablation plasma, the rf plasma beam and the substrate. The obtained films, with thicknesses in the range of 50 nm to 1 ?m have been characterized by atomic force microscopy (AFM), X-ray diffraction (XRD), transmission electron microscopy (TEM).

2005-07-15

8

Localization of small magnets against a noisy background  

Science.gov (United States)

Effective localization of small magnets against a noisy, real world background can involve various methods to first identify the magnetic fields produced by the magnet of interest, then to filter out background noise, and then to analyze the available magnetic field data to localize the magnet. Here we discuss low cost techniques which allow localization of small magnets with field strengths in the milliGauss range against real world background fields in the range of hundreds of mG, which may be fluctuating by up to tens of mG. Such techniques allow magnet tracking to be used to localize catheters in place of more invasive and expensive methods, e.g. fluoroscopy, for a variety of applications, including drug infusion with peripherally inserted central catheters (PICCs), laser ablation (TMR, PTMR) and introduction of pacemaker leads.

2001-05-01

9

Vascular Access Procedures (Central Catheters)  

Science.gov (United States)

... the major types of vascular access catheters: A peripherally inserted central catheter (PICC) is a long catheter that extends ... the procedure performed? A midline catheter and some peripherally inserted central catheter (PICC) lines may be inserted at your ...

10

Technical evaluation report for the demonstration of radio frequency soil decontamination at Site S-1  

Energy Technology Data Exchange (ETDEWEB)

The Air Force`s Armstrong Laboratory at Tyndall Air Force Base, Florida, has supported the research and development of Radio Frequency Soil Decontamination. Radio frequency soil decontamination is essentially a heat-assisted soil vapor extraction process. Site S-1 at Kelly Air Force Base, San Antonio, Texas, was selected for the demonstration of two patented techniques. The site is a former sump that collected spills and surface run-off from a waste petroleum, oils, and lubricants and solvent storage and transfer area. In 1993, a technique developed by the IIT Research Institute using an array of electrodes placed in the soil was demonstrated. In 1994, a technique developed by KAI Technologies, Inc. using a single applicator placed in a vertical borehole was demonstrated. Approximately 120 tons of soil were heated during each demonstration to a temperature of about 150 degrees Celsius.

1995-04-01

11

Central Venous Access Catheters (CVAC) and Gastrostomy (Feeding) Tubes  

Science.gov (United States)

... of CVACs, including tunneled catheters (Hickman or Broviac), peripherally inserted central catheters (also called PICC lines or long lines), ...

12

A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom  

Energy Technology Data Exchange (ETDEWEB)

A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a ...

2008-02-21

13

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

14

Effect of #gamma#-irradiation on relaxation properties of sealants on organosilicon rubber base  

International Nuclear Information System (INIS)

The dielectrical properties of organosilicon sealants have been studied in the wide range of temperatures in the low and radio frequencies range. The effect of thermal treatment and #gamma#-irradiation on these properties is discussed.

15

Electromagnetic characterization of superconducting radio-frequency cavities for gw detection  

International Nuclear Information System (INIS)

The electromagnetic properties of a prototype gravitational wave detector, based on two coupled superconducting microwave cavities, were tested. The radio-frequency (rf) detection system was carefully analysed. With the use of piezoelectric crystals small harmonic displacements of the cavity walls were induced and the parametric conversion of the electromagnetic field inside the cavities explored. Experimental results of bandwidth and sensitivity of the parametric converter versus stored energy and voltage applied to the piezoelectric crystal are reported. A rf control loop, developed to stabilize phase changes on signal paths, gave a 125 dBc rejection of the drive mode on a time scale of 1 h.

2004-03-07

16

Prospective SecurAcath Subcutaneous Securement Trial  

Science.gov (United States)

Peripherally Inserted Central Catheter

2010-02-02

18

Peripherally inserted central catheter  

Science.gov (United States)

You have a peripherally inserted central catheter (PICC). This is a tube that goes into a vein in your arm. It will help carry nutrients ...

19

Guidance for Industry  

Science.gov (United States)

... central venous catheters (tunneled [eg, Hickman], subcutaneously implanted [eg, Porta-cath], and nontunneled), peripherally inserted central venous catheters ...

20

Radio frequency plasma nitriding of aluminium at higher power levels  

International Nuclear Information System (INIS)

Nitriding of aluminium 2011 using a radio frequency plasma at higher power levels (500 and 700 W) and lower substrate temperature (500 deg. C) resulted in higher AlN/Al_2O_3 ratios than obtained at 100 W and 575 deg. C. AlN/Al_2O_3 ratios derived from X-ray photoelectron spectroscopic analysis (and corroborated by heavy ion elastic recoil time of flight spectrometry) for treatments preformed at 100 (575 deg. C), 500 (500 deg. C) and 700 W (500 deg. C) were 1.0, 1.5 and 3.3, respectively. Scanning electron microscopy revealed that plasma nitrided surfaces obtained at higher power levels exhibited much finer nodular morphology than obtained at 100 W.

2006-12-05

21

Passivation of uranium metal by radio-frequency plasma nitriding against gas phase (H{sub 2}, H{sub 2}O) corrosion  

Energy Technology Data Exchange (ETDEWEB)

Thin passive layers of uranium nitride were formed by nitriding pure metallic uranium in non-equilibrium, low pressure radio-frequency plasma of nitrogen. Plasma nitriding at low substrate temperature of 230 C-250 C was found to cause the formation of adherent layers of uranium sesquinitride ({alpha}-U{sub 2}N{sub 3}) which provide a considerable protection against hydrogen attack. The characteristics of these passivation layers were determined by X-ray diffraction and Auger electron spectroscopy. The incipient hydriding kinetics of the plasma-treated samples were compared with those of untreated and nitrogen-ion implantation ones, utilizing a hot-stage microscope that was monitored continuously with a TV camera and videotape. (orig.)

1996-07-01

22

An evaluation of the embedment of a Radio Frequency Integrated Circuit with a temperature detector in building envelopes for energy conservation  

British Library Electronic Table of Contents (United Kingdom)

Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...

2011-01-01

23

RF and microwave energy hots up  

Energy Technology Data Exchange (ETDEWEB)

The advantages of radiofrequency and microwaves, such as volumetric heating, rapid and selective heating, compactness of equipment and ease of operation, offer sound economic alternative heating techniques. This article discusses dielectric loss, its quantification, and how it is put to effective use, including the use of applicators. Brief recommendations are presented for whether to select radio frequency or microwaves for a particular application. Uses of radiofrequency and microwaves in the industrial, domestic and medical sectors are described.

1988-05-12

24

Hyperfine interactions in HCOOD and DCOOH molecules  

Energy Technology Data Exchange (ETDEWEB)

The method of double microwave--radio-frequency resonance has been used to obtain spectra of the 2/sub 11/reverse arrow2/sub 12/ and 3/sub 21/reverse arrow3/sub 22/ transitions in HCOOD, DCOOH, and HCOOH molecules. The constants of the quadrupole bond of the deuterons have been determined, magnetic interactions being taken into acocunt. A comparison with results of previous studies is given.

1986-05-01

25

Enabling Technologies for Petascale Electromagnetic Accelerator Simulation  

Energy Technology Data Exchange (ETDEWEB)

The SciDAC2 accelerator project at SLAC aims to simulate an entire three-cryomodule radio frequency (RF) unit of the International Linear Collider (ILC) main Linac. Petascale computing resources supported by advances in Applied Mathematics (AM) and Computer Science (CS) and INCITE Program are essential to enable such very large-scale electromagnetic accelerator simulations required by the ILC Global Design Effort. This poster presents the recent advances and achievements in the areas of CS/AM through collaborations.

2007-11-09

26

CRC handbook of biological effects of electromagnetic fields  

Energy Technology Data Exchange (ETDEWEB)

This book presents the current knowledge about the effects of electromagnetic fields on living matter. The three-part format covers dielectric permittivity and electrical conductivity of biological materials; effects of direct current and low frequency fields; and effects of radio frequency (including microwave) fields. The parts are designed to be consulted independently or in sequence, depending upon the needs of the reader. Useful appendixes on measurement units and safety standards are also included.

1986-01-01

27

Active RF filter for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmission lines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.

1993-07-01

31

Influence of Fiber Loading on Thermal Ablation of PTFE,  

Science.gov (United States)

... Accession Number : ADD431225. Title : Influence of Fiber Loading on Thermal Ablation of PTFE,. Corporate Author : Personal Author(s) : Letson,KN. ...

1979-07-16

33

Paracardioscopic Ex-Maze  

Medline Plus

... the pulmonary vein and because there's a gap, electricity is going across the ablation line and capturing ...

36

Surface modification of titanium by radio frequency plasma nitriding  

Energy Technology Data Exchange (ETDEWEB)

Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti{sub 2}N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 {mu}m{sup 2}/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near ...

2006-02-21

37

Surface modification of titanium by radio frequency plasma nitriding  

International Nuclear Information System (INIS)

Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti_2N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 #mu#m"2/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near to the ...

2006-02-21

38

Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy  

Energy Technology Data Exchange (ETDEWEB)

Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly developed inductively coupled RF plasma source ...

1997-09-01

39

Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy  

International Nuclear Information System (INIS)

Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly developed inductively coupled RF plasma source ...

1996-09-15

40

Radio Frequency Plasma Applications for Space Propulsion  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in solid-state radio frequency (RF) power technologies allow for the practical consideration of RF heated plasmas for space propulsion. These technologies permit the use of any electrical power source, de-couple the power and propellant sources, and allow for the effcient use of both the propellant mass and power. Effcient use of the propellant is obtained by expelling the rocket exhaust at the highest possible velocity, which can be orders of magnitude higher than those achieved in chemical rockets. Handling the hot plasma exhaust requires the use of magnetic nozzles, and the basic physics of ion detachment from the magnetic eld is discussed. The plasma can be generated by RF using helicon waves to heat electrons. Further direct heating of the ions helps to reduce the line radiation losses, and the magnetic geometry is tailored to allow ion cyclotron resonance heating. RF eld and ion trajectory calculations are presented to ...

1999-09-13

41

Electrical properties of ultra-thin oxynitrided layer using N{sub 2}O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

Energy Technology Data Exchange (ETDEWEB)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The ...

2007-06-04

42

Electrical properties of ultra-thin oxynitrided layer using N_2O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass  

International Nuclear Information System (INIS)

In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The ...

2007-06-04

43

Development of nanometer resolution C-Band radio frequency beam position monitors in the Final Focus Test Beam  

Energy Technology Data Exchange (ETDEWEB)

Using a 47 GeV electron beam, the Final Focus Test Beam (FFTB) produces vertical spot sizes around 70 nm. These small beam sizes introduce an excellent opportunity to develop and test high resolution Radio Frequency Beam Position Monitors (RF-BPMs). These BPMs are designed to measure pulse to pulse beam motion (jitter) at a theoretical resolution of approximately 1 nm. The beam induces a TM{sub 110} mode with an amplitude linearly proportional to its charge and displacement from the BPM's (cylindrical cavity) axis. The C-band (5,712 MHz) TM{sub 110} signal is processed and converted into beam position for use by the Stanford Linear Collider (SLC) control system. Presented are the experimental procedures, acquisition, and analysis of data demonstrating resolution of jitter near 25 nm. With the design of future e{sup +}e{sup -} linear colliders requiring spot sizes close to 3 nm, understanding and developing RF-BPMs will be essential in ...

1998-08-01

44

Generation and detection of superstrong shock waves during ablation of an aluminum surface by intense femtosecond laser pulses  

British Library Electronic Table of Contents (United Kingdom)

Superstrong shock waves of multimegabar level generated during ablation of an aluminum surface by intense (<1 PW/cm2) femtosecond laser pulses have been detected by observing the propagation of a shock wave in air from the ablated surface to a broadband piezoelectric receiver. The estimated initial pressure and velocity of the shock wave (ablation plume) agree well with data obtained earlier by various methods for shock waves propagating inside ablated targets.

2011-01-01

45

Radio-frequency and microwave load comprising a carbon-bonded carbon fiber composite  

Energy Technology Data Exchange (ETDEWEB)

A billet of low-density carbon-bonded carbon fiber (CBCF) composite is machined into a desired attenuator or load element shape (usually tapering). The CBCF composite is used as a free-standing load element or, preferably, brazed to the copper, brass or aluminum components of coaxial transmission lines or microwave waveguides. A novel braze method was developed for the brazing step. The resulting attenuator and/or load devices are robust, relatively inexpensive, more easily fabricated, and have improved performance over conventional graded-coating loads.

1998-01-01

46

Radio-Frequency Beam Conditioner for Fast-Wave Free-Electron Generators of Coherent Radiation  

Energy Technology Data Exchange (ETDEWEB)

A method for conditioning electron beams is proposed, making use of the TM{sub 210} mode of microwave cavities, to reduce the axial velocity spread within the beam, in order to enhance gain in resonant electron beam devices, such as the free-electron laser (FEL). Effectively, a conditioner removes the restriction on beam emittance. The conditioner is analyzed using a simple model for beam transport and ideal RF cavities. Analysis of an FEL is employed to evaluate performance with reduced axial velocity spread. Examples of FELs are presented showing the distinct advantage of conditioning.

1991-07-01

47

Radio frequency He/sup -/ source and a source of negative ions by cesium sputtering  

Energy Technology Data Exchange (ETDEWEB)

Two sources of negative ions are described. An rf source produces up to 14 ..mu..A beams of He/sup -/ by charge exchange in Rb vapor. The other Source of Negative Ions by Cesium Sputtering (SNICS) produces a wide variety of negative ion beams in the ..mu..A range. Two important features of SNICS are its simple, compact construction and its very good beam emittance (2 to 4..pi..mm mrad MeV/sup 1/2/). Both sources have lifetimes >200 hours and they are used extensively on the Wisconsin EN tandem.

1981-04-01

48

RBS Characterization of Yttrium Iron Garnet Thin Films  

International Nuclear Information System (INIS)

Magnetic materials such as yttrium iron garnet (YIG) are of great importance for its magneto-optic properties and for their potential applications in the domain of optical telecommunications. The deposition of thin films of YIG, on quartz or GGG (gadolinium gallium garnet) substrate, was performed using radio frequency non reactive magnetron sputtering, followed by high temperature annealing which is needed to enhance the crystallinity of the layers. Rutherford backscattering spectrometry RBS was used to determine the thickness and stoichiometry of the performed layers in order to investigate correlations between growth conditions and the quality of the final material. RBS measurements showed the influence of the deposition time and the temperature substrate on the film growth and its stoichiometry. (author)

2008-12-13

49

Pure NQR quantum computing  

Energy Technology Data Exchange (ETDEWEB)

It is shown that pure NQR can be utilized as a platform for quantum computing without applying a high external magnetic field. By exciting each resonance transition between quadrupole energy levels with two radio-frequency fields differing in phase and direction, the double degeneracy of the spin energy spectrum in an electric field gradient is removed. As an example, in the case of I=7/2 (nuclei {sup 133}Cs or {sup 123}Sb) the energy spectrum has eight levels which can be used as three qubits. (orig.)

2002-07-01

50

Phase formation in gas-phase combustion and pyrolysis reactions under spark and radio-frequency discharge conditions  

British Library Electronic Table of Contents (United Kingdom)

Doped ultrafine silicon dioxide powder with a narrow particle size distribution was obtained by RF discharge-stimulated dichlorosilane (SiH2C) oxidation at a low pressure using isobutylene as the combustion inhibitor and chromium hexacarbonyl (Cr(CO)6) as the dopant. The formation and morphology of the ultrafine particles are governed by the parameters of the RF discharge and by the chemical mechanism of the combustion reaction yielding the aerosol. Submicron-sized filamentous carbon structures can be obtained by isobutylene decomposition under spark discharge conditions in the presence of a molybdenum metal catalyst.

2009-01-01

51

Operational status of the Brookhaven National Laboratory Accelerator Test Facility  

International Nuclear Information System (INIS)

Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2#pi#/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures.

1990-06-11

52

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

53

Initial RF measurements of the CW normal-conducting RF injector  

Energy Technology Data Exchange (ETDEWEB)

The LANL 2.5-cell, normal-conducting radio-frequency (NCRF) injector has been fabricated. We present initial results of low-power RF measurements (cavity Q, cavity field map, coupling beta, etc.) of the NCRF injector. The measured cavity Q and relative fields are found to be in good agreement with the design calculations and earlier measurements of Glidcop properties. However, the coupling beta of the ridge-loaded waveguides is found to be significantly higher than the design point. The impact of these low-power measurement results on the planned high-power RF and electron beam tests will be discussed.

2008-01-01

54

High-current negative-ion beam transport  

Energy Technology Data Exchange (ETDEWEB)

The requirements for transporting high-current, negative-ion beams are presented with particular emphasis on applications involving negative-hydrogen-ion beams. In addition to the usual matching and steering problems, particular attention must be paid to beam emittance growth in the transport system. Depending on the application, a number of approaches have been developed using both magnetic and electric lenses. I discuss the design considerations for transporting and matching these beams to radio-frequency quadrupole accelerators, and present a survey of the various types of beamlines now used for negative-ion beams.

1992-10-05

55

5 GHz 200 Mbit/s radio over polymer fibre link with envelope detection at 650 nm wavelength  

DEFF Research Database (Denmark)

All-optical envelope detection of a 5 GHz 200 Mbit/s modulated radio frequency signal is achieved using a 650 nm resonant cavity light emitting diode. Error-free transmission is achieved over a 50 m-long link of 1 mm diameter graded index polymer optical fibre (POF). The presented system has potential applications in low cost and low complexity short range wireless and wireline POF-based transmission links.

2008-01-01

56

Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) ...

2008-11-15

57

Sustaining reductions in catheter related bloodstream infections in Michigan intensive care units: observational study  

UK PubMed Central (United Kingdom)

Objectives To evaluate the extent to which intensive care units participating in the initial Keystone ICU project sustained reductions in rates of catheter related bloodstream infections.Design...Full Text Available

2010-01-01

58

Enhancing Process and Data Collection Efficiency of Peripherally Inserted Central Catheter Insertion for Justification of an Intravenous Access Program.  

Science.gov (United States)

This purpose of this paper is to describe the optimizing Peripherally Inserted Central Catheter (PICC) insertion, revising data collection strategies, estimating workloads, and calculating the financial savings generated by the vascular access nurse (VAN)...

2004-01-01

60

Delayed Development of Pneumothorax After Pulmonary Radiofrequency Ablation  

International Nuclear Information System (INIS)

Acute pneumothorax is a frequent complication after percutaneous pulmonary radiofrequency (RF) ablation. In this study we present three cases showing delayed development of pneumothorax after pulmonary RF ablation in 34 patients. Our purpose is to draw attention to this delayed complication and to propose a possible approach to avoid this major complication. These three cases occurred subsequent to 44 CT-guided pulmonary RF ablation procedures (6.8%) using either internally cooled or multitined expandable RF electrodes. In two patients, the pneumothorax, being initially absent at the end of the intervention, developed without symptoms. One of these patients required chest drain placement 32 h after RF ablation, and in the second patient therapy remained conservative. In the third patient, a slight pneumothorax at the end of the intervention gradually increased and led into tension pneumothorax 5 days ...

2009-05-01

61

RF tumor ablation with internally cooled electrodes and saline infusion: what is the optimal location of the saline infusion?  

UK PubMed Central (United Kingdom)

BackgroundRadiofrequency ablation (RFA) of tumors by means of internally cooled electrodes (ICE) combined with interstitial infusion of saline may improve clinical results. To date,...Full Text Available

62

Percutaneous core excision and radiofrequency thermo-coagulation for the ablation of osteoid osteoma of the spine  

UK PubMed Central (United Kingdom)

Percutaneous radiofrequency ablation is the treatment of choice for osteoid osteoma of the appendicular skeleton. However, difficulties in localizing the lesion in the spine and its proximity to neural...Full Text Available

2009-03-01

63

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...

1996-11-01

64

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...

1995-10-01

65

Radio and television interference caused by corona discharges from high-voltage transmission lines  

International Nuclear Information System (INIS)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...

1996-04-09

66

Magnetic layer formation on plasma nitrided CoCrMo alloy  

British Library Electronic Table of Contents (United Kingdom)

In this study structural and magnetic character of the expanded austenite phase (gN) layer formed on a medical grade CoCrMo alloy by a low-pressure Radio-Frequency plasma nitriding process was investigated. The formation of the expanded austenite phase is facilitated at a substrate temperature near 400^oC for 1, 2, 4, 6 and 20h under a gas mixture of 60% N2-40% H2. The magnetic state of the gN layers was determined by a surface sensitive technique, magneto-optic Kerr effect (MOKE), and with a scanning probe microscope in magnetic force mode (MFM). Strong evidence for the ferromagnetic nature of the gN-(Co,Cr,Mo) phase is provided by the observation of stripe domain structures and the hysteresis loops. The ferromagnetic state for the gN phase observed here is mainly linked to large lattice ...

2011-01-01

67

Investigation of methods for improving models of ionospheric plasma-density irregularities and radio-frequency scintillation. Technical report  

Energy Technology Data Exchange (ETDEWEB)

Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.

1993-11-01

68

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron radiography imaging means may be employed to ...

1991-10-02

69

Effects of sputtering pressure on the characteristics of lithium ion conductive lithium phosphorous oxynitride thin film  

British Library Electronic Table of Contents (United Kingdom)

Lithium phosphorous oxynitride(Lipon) thin films as a lithium ion conductive electrolyte were prepared by radio frequency reactive sputtering in N2 plasma. The properties of the amorphous Lipon solid electrolyte were investigated as a function of N2 pressure during reactive sputtering. The ionic conductivity and the electrochemical stability of Lipon thin films improved drastically as the N2 pressure decreased. The ionic conductivity closed to 10?6 S cm?1 and obtained a stability window of 1.0?5.0 V with an N2 pressure of 5 mTorr, where the number of nitrogen bonds between the phosphate groups were more than those formed at higher pressure. It was possible to fabricate the Li//LiCoO2 complete thin film battery using this Lipon solid electrolyte, which exhibited excellent discharge characte...

2006-01-01

70

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

71

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)

2008-05-01

72

A study on rf plasma nitriding at a constant power in different H_2-N_2 mixtures at different temperatures  

International Nuclear Information System (INIS)

Austenitic stainless steel AISI 304 has been nitrided by radio frequency (rf) plasma containing various nitrogen-hydrogen gas mixtures, in order to study the effect of hydrogen on structure and magnetic properties of the formed compound layer. The thermal temperature has been measured at the vicinity of the samples. The compound layer thus produced has been characterized using, X-ray diffractometer and vibration sample magnetometer. Providing the total pressure of nitrogen and hydrogen is held constant, the addition of hydrogen up to 50% gives new structural phases. The magnetization values of the plasma treated samples are strongly dependent on the percentage of H_2 in the gas phase. An excessive amount of hydrogen (#approx#75%) on the other hand, retards the nitriding process. The surface temperature of the sample and plasma condition is crucial factors for nitriding process.

2006-04-15

73

A proposed linac cavity rf drive system for the Los Alamos extreme ultraviolet free-electron laser  

Energy Technology Data Exchange (ETDEWEB)

Since 1979, scientists and engineers at the Los Alamos National Laboratory have designed, constructed, and operated a radio-frequency (RF) linac free-electron laser (FEL) at wavelengths from 9 to 45 /mu/m. Coupled with success of other research centers investigating wavelengths from the visible to far-infrared, Los Alamos is now proposing a vacuum-ultraviolet and soft x-ray (referred to henceforth as extreme ultraviolet, (XUV)) FEL oscillator/Self-Amplified Spontaneous Emission amplifier with beam energies ranging from 100 MeV to 1 GeV. This paper will focus on the first milestone of the proposed Los Alamos XUV project, i.e., a 250-MeV linac with approximately 50 mA of average current, producing photons with wavelengths below 1000 /angstrom/. 3 refs., 3 figs.

1989-01-01

74

A nanosized silicon thin film as high capacity anode material for Li-ion rechargeable batteries  

Energy Technology Data Exchange (ETDEWEB)

Silicon thin film with thickness in range 1000-5300 A deposited on rough Cu foil by a radio frequency magnetron sputtering is used as anode materials for Li-ion rechargeable batteries. The SEM, XRD and TEM analysis reveals that the Si thin film has a floccular nano-sized multi-crystalline structure. Li ions insertion/extraction evaluation is performed mainly with constant current charge/discharge cycling and cyclic voltammetry (CV) at room temperature. The cycleability and reversible discharge capacity are found to depend on the film thickness, and thinner films give larger accommodation capacity. A 3120 A Si film provides a reversible specific capacity over 3500 mA hg{sup -1} with excellent cycleability under 0.5 C charge/discharge rate.

2006-07-15

75

Wiswell, Thomas CV  

Science.gov (United States)

... Ashton WS, Puntel RA, Wiswell TE. A rapid and readily available repair of the peripherally inserted central catheter in the nursery. NEONATAL INTENSIVE CARE 11 ...

76

Outcome of peripherally inserted central venous catheters in surgical and medical neonates  

British Library Electronic Table of Contents (United Kingdom)

Background/Purpose: Peripherally inserted central venous catheters (PICCs) are commonly used for neonatal vascular access. The aim of this study was to look at PICC line complication rates and possible predictors of PICC infection in a neonatal intensive care unit. Method: This was a prospective study of 226 neonates who had PICCs on our neonatal intensive care unit between January 2006 and June 2009. Complete data was available on 218 neonates who had 294 PICC lines. Criteria for catheter-related sepsis was positive blood cultures (peripheral/central) and/or a positive catheter tip culture after removal in the presence of a clinical suspicion of line sepsis. Results: Of 218 neonates, 132 (169 lines) were medical, and 86 (125 lines) were surgical. Our PICC line infection rate was 17 infect...

2011-01-01

77

Implementation of an Intravenous/Phlebotomy Team at Walter ...  

Science.gov (United States)

... dressing changes and site care, mid-line placement, placement of peripherally inserted central catheters, heparin locks, and patient education. ...

1993-08-01

79

Cardiac Atrophy and Diastolic Dysfunction ... - LSDA - Experiment  

Science.gov (United States)

... and Cardiac Function test (including optional measurements of central venous pressure (CVP), via a peripherally inserted central catheter, and cardiac output ...

80

Use of a Peripherally Inserted Central Catheter as a Conduit for Central Venous Access Across Thrombosed Great Veins  

Science.gov (United States)

This report describes a technique of inserting an implantable venous access port (portacath) through a thrombosed and occluded vein employing a pre-existing peripherally inserted central catheter (PICC) as the route of access. The PICC was used as a conduit for venous access in a way that has not been described previously in the literature. This procedure was performed in a young patient with cystic fibrosis in an effort to prevent the use of his virgin contralateral veins, which might be used in the future.

2010-02-15

81

Search Results - NASA Technical Reports Server  

Science.gov (United States)

The influence of ablation on stagnation region convective heating for ... and thermal properties of this fiber depend on the fluorination process ... However, these properties are between those of graphite and those of PTFE (Teflon). ...

82

:z:..... \\ - NASA Technical Report Server (NTRS)  

Science.gov (United States)

A common reinforced liner material is a cloth formed of PTFE fibers and fiber of ... and ablation protection provided. All of these methods of thermal ..... The influence of fiber content on the microstructures of the composites is ...

83

8 - NASA Technical Reports Server  

Science.gov (United States)

The influence of ablation on stagnation region convective heating for ... and thermal properties of this fiber depend on the fluorination process ... However, these properties are between those of graphite and those of PTFE (Teflon). ...

84

120-MM Gun Tube Erosion Including Surface Chemistry ...  

Science.gov (United States)

... with dynamic gridding capability to account for material ablation, as well as the addition of energy sources and heat transfer augmentation due to ...

1997-10-01

85

/ /tLc - NASA Technical Reports Server  

Science.gov (United States)

Inertial navigation error propagation. Hypersonic entry guidance techniques. Ablation effects on hypersonic aero-. Primary navigation and guidance ...

86

Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement  

Science.gov (United States)

The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. ...

2003-04-15

87

Percutaneous mechanical declotting of thrombosed dialysis graft  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the effectiveness of percutaneous mechanical declotting. Using a 7-F Desilets-Hoffman sheath and the crossed-catheter technique, we aspirated the intragraft clot and pushed the residual clot into the central circulation with balloon catheters. The success rate, procedure time, complications and patency rates were evaluated. Technical success was achieved in 24 of 32 cases, with a procedure time of 30-240 (average, 111) minutes. In five of eight cases in which technical failure occurred, the guide wire failed to reach the stenotic site and in the other three, there was insufficient luminal dilatation. Complications included vein ruptures (n=2), arterial emboli (n=1) and arterial dissection (1), but there was no evidence of clinical symptoms of pulmonary embolism. The six-month patency rate was 67.8%. Mechanical declotting of thrombosed dialysis graft using a balloon catheter is relatively inexpensive, safe and ...

2000-10-01

88

Pulmonary vein ablation for idiopathic atrial fibrillation: six month outcome of first procedure in 100 consecutive patients  

UK PubMed Central (United Kingdom)

Objectives: To report six month outcome in patients undergoing their first pulmonary vein ablation procedure for idiopathic atrial fibrillation (AF) at a “non-pioneering”...Full Text Available

2005-01-01

89

Method of defining features on materials with a femtosecond laser  

Energy Technology Data Exchange (ETDEWEB)

The invention relates to a pulsed laser ablation method of metals and/or dielectric films from the surface of a wafer, printed circuit board or a hybrid substrate. By utilizing a high-energy ultra-short pulses of laser light, such a method can be used to manufacture electronic circuits and/or electro-mechanical assemblies without affecting the material adjacent to the ablation zone.

2006-05-23

90

Formation of nano-sized particles of a solid electrolyte by laser ablation  

Energy Technology Data Exchange (ETDEWEB)

Nano-sized particles of a lithium ion conductive solid electrolyte, LiTi{sub 2}(PO{sub 4}){sub 3}, were prepared by laser ablation. The obtained particles were ca. 10nm in diameter. X-ray powder diffraction and Raman spectroscopy showed that they were amorphous with local structure similar to the crystalline counterpart. They were crystallized by the heating at ca. 630{sup o}C. (author)

2005-08-26

91

Gelatin ablation wavelength dependency in the range of 5.6-6.7 #mu#m using a mid-infrared Free Electron Laser  

International Nuclear Information System (INIS)

Efficient and precise ablation of soft tissue is needed for non-invasive dermatological and corneal surgeries. Previous research has revealed that smooth and efficient cutting of certain soft tissues and gelatin is possible using a Free Electron Laser (FEL) with a wavelength of #lambda#=6.45 #mu#m, tuned to the amide-II band of protein. Gelatin ablation experiments have been carried out using a mid-infrared FEL within the waveband #lambda#=5.6-6.7 #mu#m by changing the primary absorbers such as water (#lambda#=6.1 #mu#m) and protein (#lambda#=6.45 #mu#m). The gelatin with 80 wt% water was efficiently ablated by FEL irradiation with the waveband #lambda#=#approx#5.95-6.19 #mu#m. On the other hand, using irradiation within #lambda#=#approx#6.4-6.6 #mu#m, many small bubbles were observed in the irradiated volume, and the gelatin was not ablated but significantly melted. Thus, it was found that the most ...

2003-07-11

92

Spontaneous emission spectra and simulating multiple spontaneous generation coherence in a five-level atomic medium  

Science.gov (United States)

We investigate the features of the spontaneous emission spectra in a coherently driven cold five-level atomic system by means of a radio frequency (rf) or microwave field driving a hyperfine transition within the ground state. It is shown that a few interesting phenomena such as spectral-line narrowing, spectral-line enhancement, spectral-line suppression, and spontaneous emission quenching can be realized by modulating the frequency and intensity of the rf-driving field in our system. In the dressed-state picture of the coupling and rf-driving fields, we find that this coherently driven atomic system has three close-lying levels so that multiple spontaneously generated coherence (SGC) arises. Our considered atomic model can be found in real atoms, such as rubidium or sodium, so a corresponding experiment can be done to observe the expected phenomena related to SGC reported by Fountoulakis et al. [Phys. Rev. A 73, 033811 (2006)], since no ...

2006-09-15

93

Radio-frequency optical double-resonance spectrum of SrF: the X/sup 2/. sigma. /sup +/ state  

Energy Technology Data Exchange (ETDEWEB)

The isotropic and anisotropic hyperfine constants of the ground X/sup 2/..sigma../sup +/ state of /sup 88/SrF and /sup 86/SrF are reported. Vibrational and rotational dependences are studied in a Dunham expansion analysis. Furthermore, the vibrational, rotational, and isotopic dependence of the spin-rotation constant is determined. The following values are obtained for X/sup 2/..sigma../sup +/, ..nu.. = 0, in /sup 88/SrF: ..gamma../sub 0/ = 74.79485 MHz, ..gamma../sub 1/ = 5.752 x 10/sup -5/ MHz, ..gamma../sub 2/ = -6.3 x 10/sup -10/ MHz, b/sub 0/ = 97.0834 MHz, b/sub 1/ = -3.300 x 10/sup -4/ MHz, c/sub 0/ = 30.268 MHz, C/sub I/ = 0.00230 MHz, where ..gamma.. is the spin-rotation parameter, b and c are the Frosch and Foley hyperfine parameters, and C/sub I/ is a nuclear spin-rotation correction. 4 figures, 4 tables.

1981-01-01

94

Polarised foreground removal at low radio frequencies using rotation measure synthesis: Uncovering the signature of hydrogen reionisation  

CERN Document Server

Measurement of redshifted 21-cm emission from neutral hydrogen promises to be the most effective method for studying the reionisation history of hydrogen and, indirectly, the first galaxies. These studies will be limited not by raw sensitivity to the signal, but rather, by bright foreground radiation from Galactic and extragalactic radio sources and the Galactic continuum. In addition, leakage due to gain errors and non-ideal feeds conspire to further contaminate low-frequency radio obsevations. This leakage leads to a portion of the complex linear polarisation signal finding its way into Stokes I, and inhibits the detection of the non-polarised cosmological signal from the epoch of reionisation. In this work, we show that rotation measure synthesis can be used to recover the signature of cosmic hydrogen reionisation in the presence of contamination by polarised foregrounds. To achieve this, we apply the rotation measure synthesis technique to the Stokes I component of a synthetic data ...

2010-01-01

95

Photovoltaic Technologies Beyond the Horizon: Optical Rectenna Solar Cell, Final Report, 1 August 2001-30 September 2002  

Energy Technology Data Exchange (ETDEWEB)

ITN Energy Systems is developing next-generation solar cells based on the concepts of an optical rectenna. ITN's optical rectenna consists of two key elements: (1) an optical antenna to efficiently absorb the incident solar radiation, and (2) a high-frequency metal-insulator-metal (MIM) tunneling diode that rectifies the AC field across the antenna, providing DC power to an external load. The combination of a rectifying diode at the feedpoints of a receiving antenna is often referred to as a rectenna. Rectennas were originally proposed in the 1960s for power transmission by radio waves for remote powering of aircraft for surveillance or communications platforms. Conversion efficiencies greater than 85% have been demonstrated at radio frequencies (efficiency defined as DC power generated divided by RF power incident on the device). Later, concepts were proposed to extend the rectennas into the IR and optical region of the ...

2003-02-01

96

Performance enhancement of a compact radio frequency ion source by the injection of supplemental electrons  

Energy Technology Data Exchange (ETDEWEB)

A versatile, high brightness, volume type, low power RF source, capable of producing positive ion beams with intensities as high as 1 mA from gaseous feed materials and microamperes of negative ion beams has been characterized. The source can also be operated as a plasma sputter negative ion source to generate up to 1 mA of a selected species. The performance of the source in the positive and negative volume modes of operation can be greatly enhanced by addition of a removable, water cooled filament assembly in place of the negative sputter probe. For examine, the material utilization efficiencies of gaseous feed species can be more than doubled, total current intensities increased up to 40%, molecular dissociation fractions increased by 20% and minimum operating pressures reduced by a factor of four when operated in the volume mode. These added electrons also favorably effect, as a consequence of lower pressures, the emittance apparently through a reduction of scattering in the beam ...

1995-07-01

97

Novel InN growth method under In-rich condition on GaN/Al2O3(0001) templates  

International Nuclear Information System (INIS)

A novel technique is proposed for the growth of an InN film on a GaN/Al2O3(0001) template by radio-frequency plasma-excited molecular beam epitaxy (RF-MBE). The method involves 1) InN growth under an In-rich condition and 2) additional nitrogen radical irradiation after the InN growth under an In-rich condition. Excess In that appeared on the InN surface in the InN growth under an In-rich condition is transformed to InN by the additional nitrogen radical irradiation. The effective V/III ratio is easily controlled by monitoring the intensity in a reflection high-energy electron diffraction (RHEED) pattern. The growth of the InN film by repeating the InN growth under an In-rich condition and the additional nitrogen radical irradiation is also demonstrated. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

2009-06-01

98

Lubrication properties of molybdenum disulfide films deposited by RF sputtering method  

Energy Technology Data Exchange (ETDEWEB)

A radio frequency sputtering apparatus with a pair of targets has been developed for depositing a film of uniform thickness onto a complex-geometric specimen such as the retainer of a ball bearing. The deposition characteristics of the apparatus were compared with those of the conventional sputtering apparatus. Lubrication properties of MoS/sub 2/ films made by these devices were also compared under a variety of conditions. Finally, friction and wear of MoS/sub 2/ films applied to angular-contact type ball bearings of 20 mm bore were studied in air, nitrogen and vacuo. The two-target sputtering has an advantage mentioned above. However, the films deposited by the method exhibited a rather short wear life because of the temperature rise of the substrate during ion bombardment and during the sputtering process. This temperature dependence was observed in films on those substrates that had been heated with a built-in heater during sputtering. The ...

1986-01-01

99

Integrated plasma synthesis of efficient catalytic nanostructures for fuel cell electrodes  

International Nuclear Information System (INIS)

A single plasma process involving three consecutive steps has been developed for producing high gas flow catalytic nanostructures on the electrodes of proton exchange membrane (PEM) fuel cells (FC). Using a high density helicon radio frequency (13.56 MHz) plasma, nickel is sputtered onto a porous carbon support. Changing the background gas from argon to methane/hydrogen allowed 2 ?m long, 37 nm diameter carbon nanofibres (CNFs) to be grown by diffusion through the nickel clusters in a 'tip growth' mechanism at the relatively low temperature of 400 deg. C. The third step involves plasma sputtering of platinum onto the CNFs, resulting in nanoclusters (3-8 nm) being formed on the periphery of the CNFs. Four FC cathodes were synthesized on carbon paper and PTFE/carbon loaded cloth (known as gas diffusion layer, GDL), both with and without CNFs, with the Pt/CNFs nanostructures grown on PTFE/carbon loaded cloth having the best FC performances. ...

2007-08-01

100

Influence of the Alfven wave spectrum on the scrape-off layer of the TCA tokamak  

International Nuclear Information System (INIS)

The study of the scrape-off layer (SOL) during Alfven wave heating may lead to a better understanding of the antenna-plasma interaction. The scrape-off layer of the TCA tokamak has been widely investigated by means of Langmuir probes. The aim of this work is to present measurements on the influence of the Alfven wave spectrum on the scrape-off layer. These experiments have shown that the plasma boundary layer is strongly affected by the wave field, in particular the ion saturation current and the floating potential. In TCA, as the spectrum evolves due to a density rise, the passage of the Alfven continua and their associated eigenmodes, the Discrete Alfven Wave (DAW) induces a strong depletion in the edge density of up to 70% during the continuum part and a density increase during the crossing of an eigenmode. The floating potential becomes negative during the continua and even more negative crossing the eigenmodes. In case of MHD mode activity, this behaviour changes for power ...

1988-05-01

101

Industrial applications of the Jefferson Lab high-power free-electron laser  

International Nuclear Information System (INIS)

In partnership with the US Navy, high-technology corporations, and research universities, Jefferson Lab is building a superconducting radio-frequency (SRF) accelerator-driven free-electron laser (FEL) and is outfitting an FEL user facility. This first fourth-generation light source - a 1 kW, 3 #mu#m infrared (IR) laser - is the first step in a program to develop high-average-power SRF-based IR and ultraviolet (UV) FELs for multiple manufacturing applications as well as for defense-related applied research and basic scientific research. This initial FEL will be driven by a 42 MeV, 5 m A recirculating SRF linac similar to the much larger SRF linac in Jefferson Lab's 4 GeV, 200 #mu#A Continuous Electron Beam Accelerator Facility (CEBAF). The FEL is expected to demonstrate 75% energy recovery. Its linac will be cooled by the existing CEBAF cryogenic system. At Jefferson Lab, an infrastructure of facilities and people already supports the advance of SRF and closely ...

1998-09-02

102

IN VACUUM UNDULATOR TASK FORCE REPORT  

Energy Technology Data Exchange (ETDEWEB)

The Green-Chasman lattice, which is the basis for both NSLS storage rings, was conceived with insertion devices in mind. Long, field-free straight sections were provided in the design. The electron optics were chosen so that these sections had zero dispersion and the effects of new magnetic structures placed in these regions would have minimal effect on the emittance of the electron beam. This design concept has been followed by all high-brightness rings which were built subsequent to the NSLS. The X-Ray Ring straight sections also have a very small vertical {beta} function, in addition to the zero dispersion. This was done to optimize the brightness of wiggler sources. There is a further benefit however. The {beta} function determines the beam size and divergence at a particular point in the storage ring lattice. The size is proportional to {radical}{beta} and the divergence is proportional to 1/{radical}{beta}. Thus the electron beam is very small at the center of the X-Ray Ring ...

1998-06-01

103

FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure  

Energy Technology Data Exchange (ETDEWEB)

The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg{sup -1}, which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface area-to-mass ratio.

2008-09-21

104

Enhancement of surface properties of 45{number_sign} steel using plasma immersion ion implantation  

Energy Technology Data Exchange (ETDEWEB)

45{number_sign} steel, which has good mechanical strength and is relatively cheap, is a common constituent in industrial components, such as precision gears, piston columns of oil pumps, and so on. However, since the working environment of these industrial parts is sometimes quite harsh and unforgiving, they are vulnerable to wear and corrosion. Replacing 45{number_sign} steel with stainless or alloy steel increases the cost significant, and a better alternative is to improve its surface properties and lifetime using plasma immersion ion implantation (PIII). The authors have devised a variety of treatment processes using PIII, including radio-frequency (RF) plasma nitriding, RF plasma nitriding and nitrogen PIII, Ti deposition in conjunction with nitrogen PIII (IBED), as well as Cr deposition followed by nitrogen PIII (IBED). To assess the efficacy of the processes, the microhardness and mass loss due to wear were measured for both the untreated and treated ...

1997-12-31

105

Electromagnetic radiation unmasked  

International Nuclear Information System (INIS)

This article describes the nature of the electromagnetic waves, what they are and how do they affect us. Current concern is focused on exposure to low level power-frequency magnetic fields like microwave radiation from mobile phones and leaking microwave ovens; high power radiation from defence and airport radars; fields close to high voltage transmission lines; radio frequency fields from industrial welders and heaters and DC magnetic fields in aluminium smelters. These fields with frequency less than 300 GHz do not carry sufficient energy to break chemical bonds and it is assumed that they cannot damage cell DNA. The amount of radiation absorbed by a human exposed to far field electromagnetic radiation (EMR) depends on the orientation and size of the person. In the 30-300 MHz range it is possible to excite resonance in the whole or partial body such as the head. It is emphasised that since there are some evidence that electromagnetic fields ...

1996-01-01

106

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is ...

2002-01-01

107

Behavior of the positron beam of the Super-ACO storage ring in response to a modification of the RF frequency for free-electron laser experiments  

International Nuclear Information System (INIS)

The macrotemporal structure of the Super-ACO Storage ring free-electron laser (FEL) can be either continuous, pulsed, or chaotic, and can present some rapid fluctuations. The temporal evolution of a storage ring FEL involves both the longitudinal motion of the positron beam (especially the synchrotron oscillations) and the FEL dynamics, as in a coupled system. Studies on the dynamics of the positron beam are performed here, in the goal to have a stable source for FEL applications, and to determine the conditions for a stable Q-switching experiment. The employed method is to study the influence of a controlled change of the radio frequency (RF) (modulation or frequency jump) on the beam. A simple theoretical model taking into account the perturbed RF system is presented to help the understanding of the experimental data. The different methods of measurement are described. Then, the results are given for several experimental conditions and the ...

108

Adaptive and mobile ground sensor array.  

Energy Technology Data Exchange (ETDEWEB)

The goal of this LDRD was to demonstrate the use of robotic vehicles for deploying and autonomously reconfiguring seismic and acoustic sensor arrays with high (centimeter) accuracy to obtain enhancement of our capability to locate and characterize remote targets. The capability to accurately place sensors and then retrieve and reconfigure them allows sensors to be placed in phased arrays in an initial monitoring configuration and then to be reconfigured in an array tuned to the specific frequencies and directions of the selected target. This report reviews the findings and accomplishments achieved during this three-year project. This project successfully demonstrated autonomous deployment and retrieval of a payload package with an accuracy of a few centimeters using differential global positioning system (GPS) signals. It developed an autonomous, multisensor, temporally aligned, radio-frequency communication and signal processing capability, and an array ...

2003-12-01

109

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China (10475112), Western Light Foundation of Chinese ...

2008-05-01

110

High-power radio frequency pulse generation and extraction based on wakefield excited by an intense charged particle beam in dielectric-loaded waveguides  

International Nuclear Information System (INIS)

Power extraction using a dielectric-loaded (DL) waveguide is a way to generate high-power radio frequency (RF) waves for future particle accelerators, especially for two-beam-acceleration. In a two-beam-acceleration scheme, a low-energy, high-current particle beam is passed through a deceleration section of waveguide (decelerator), where the power from the beam is partially transferred to trailing electromagnetic waves (wakefields); then with a properly designed RF output coupler, the power generated in the decelerator is extracted to an output waveguide, where finally the power can be transmitted and used to accelerate another usually high-energy low-current beam. The decelerator, together with the RF output coupler, is called a power extractor. At Argonne Wakefield Accelerator (AWA), we designed a 7.8GHz power extractor with a circular DL waveguide and tested it with single electron bunches and bunch trains. The output RF frequency (7.8GHz) ...

111

What Parents Should Know about Medical Radiation Safety in Interventional Radiology  

Science.gov (United States)

... Amount Background Radiation Blood vessel central line, PICC (peripherally inserted central catheter) or port placement, simple 0.4 mSv ...

112

Pericardial tamponade in a newborn following umbilical catheter insertion.  

Science.gov (United States)

We present a case of cardiac tamponade following umbilical venous catheterization in a neonate, an uncommon, yet potentially fatal complication. Timely diagnosis by echocardiography and urgent pericardiocentesis proved lifesaving. PMID:21654008

2011-05-01

113

Making the Hospital Safer for Older Adult Patients: A Focus on the Indwelling Urinary Catheter  

UK PubMed Central (United Kingdom)

The needs of hospitalized geriatric patients differ from the needs of hospitalized younger adults. In an attempt to improve systems of care for the older adult, the Centers for Medicare and Medicaid...Full Text Available

2011-01-01

114

Heterotopic transcatheter tricuspid valve implantation: first-in-man application of a novel approach to tricuspid regurgitation  

UK PubMed Central (United Kingdom)

AimsTranscatheter treatment of heart valve disease is well established today. However, for the treatment of tricuspid regurgitation (TR), no effective catheter-based approach is...Full Text Available

2011-05-01

115

Convection-enhanced delivery of maghemite nanoparticles: Increased efficacy and MRI monitoring  

UK PubMed Central (United Kingdom)

Convection-enhanced drug delivery (CED) is a novel approach to delivering drugs into brain tissue. Drugs are delivered continuously via a catheter, enabling large volume distributions of high drug concentrations...Full Text Available

2008-04-01

116

Changes in colonic motility induced by sennosides in dogs: evidence of a prostaglandin mediation.  

UK PubMed Central (United Kingdom)

The effects of sennosides on colonic motility were investigated in eight conscious dogs chronically fitted with two strain gauge transducers in the proximal colon, an intracolonic silicone catheter...Full Text Available

1988-09-01

117

Bleeding during cancer treatment: MedlinePlus Medical Encyclopedia  

Science.gov (United States)

- flushing Chemotherapy - what to ask your doctor Dry Mouth Oral mucositis Peripherally inserted central catheter Radiation therapy - what to ask your doctor Safe drinking during...

2011-08-09

118

Nanoparticle formation during laser ablation of metals at different pressures of surrounding noble gases  

Energy Technology Data Exchange (ETDEWEB)

We demonstrate that the nanoparticle formation during laser ablation of metals by short (of a few tens of ps) laser pulses strongly depends on the concentration of surrounding gas. While, at vacuum conditions, nanoparticle formation shows very ''sharp'' atomic force microscope images of aggregated clusters, following with clear appearance of plasmon resonance on the absorption spectra of deposited films, an addition of gas particles starts to decrease the probability of cluster formation. This process shows a threshold for both helium (33 torr) and xenon (12 torr) above which no surface plasmon resonance and correspondingly no observable nanoparticles on the deposited surfaces were detected. The destruction of nanoparticle formation was attributed to the negative influence of surrounding gas particles on ablated particles aggregation. (orig.)

2010-07-15

119

Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with ...

2007-10-01

120

Radiofrequency ablation of lung and liver lesions using CT fluoroscopy  

International Nuclear Information System (INIS)

Full text: Tumour ablation with radiofrequency (RF) energy is a relatively new procedure for the treatment of focal malignant disease. At our institution this is currently being used in the treatment of certain liver and lung lesions with the patients involved being enrolled in clinical trials. The poster describes the technique used at our institution for the placement of the radiofrequency ablation electrode using CT fluoroscopy. Criteria for patient selection are included. Complications from the procedure are described, as well as follow up appearances and results. Our results from the treatment of primary and secondary lesions in the liver correlate well with published literature. Treatment is still not as successful as surgical resection but there is significantly less morbidity. Where this method may be appropriate is when the patient is not a candidate for surgical resection. The treatment of colorectal metastases in the lung shows early ...

2002-06-01

121

Quality-of-Life and Surgical Treatments for Rectal Cancer-a Longitudinal Analysis Using the California Cancer Registry  

UK PubMed Central (United Kingdom)

BackgroundHeterogeneous results for research investigating health-related quality of life (HRQL) in patients undergoing sphincter-ablating procedures for rectal cancer...Full Text Available

2010-08-01

122

Prognostic determinants for survival after resection/ablation of a large hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

Background:Liver resection of large hepatocellular carcinomas (HCC), measuring at least 10 cm remains a controversial debate. Multiple studies on HCCs treated with surgical resection...Full Text Available

2009-06-01

123

Micropatterned polysaccharide surfaces via laser ablation for cell guidance  

Energy Technology Data Exchange (ETDEWEB)

Micropatterned materials were obtained by a controlled laser ablation of a photoimmobilised homogeneous layer of hyaluronic acid (Hyal) and its sulphated derivative (HyalS). The photoimmobilisation was performed by coating the polysaccharide, adequately functionalised with a photoreactive group, on aminosilanised glass substrate and immobilising it on the surface under UV light. Hyal or HyalS photoimmobilised samples were then subjected to laser ablation with wavelengths in the UV regions in order to drill the pattern. Four different patterns with stripes of 100, 50, 25 and 10 {mu}m were generated. A chemical characterisation by attenuated total reflection/Fourier transform infrared (ATR/FT-IR) and time of flight-secondary ions mass spectrometry (TOF-SIMS) confirmed the success of the laser ablation procedure and the presence of alternating stripes of polysaccharide and native glass. The exact dimensions of the stripes were ...

2003-03-03

124

Metal stenting to resolve post-photodynamic therapy stricture in early esophageal cancer  

UK PubMed Central (United Kingdom)

Photodynamic therapy (PDT) is an established endoscopic technique for ablating Barrett’s esophagus with high-grade dysplasia or early-stage intraepithelial neoplasia. The most common clinically...Full Text Available

2011-03-14

125

Genetic Ablation of NADPH Oxidase Enhances Susceptibility to Cigarette Smoke-Induced Lung Inflammation and Emphysema in Mice  

UK PubMed Central (United Kingdom)

Cigarette smoke (CS) induces recruitment of inflammatory cells in the lungs leading to the generation of reactive oxygen species (ROS), which are involved in lung inflammation and injury. Nicotinamide...Full Text Available

2008-05-01

126

Functional Analysis of the Murine Cytomegalovirus Chemokine Receptor Homologue M33: Ablation of Constitutive Signaling Is Associated with an Attenuated Phenotype In Vivo?  

UK PubMed Central (United Kingdom)

The murine cytomegalovirus (MCMV) M33 gene is conserved among all betaherpesviruses and encodes a homologue of seven-transmembrane receptors (7TMR) with the capacity for constitutive signaling. Previous...Full Text Available

2008-02-01

127

Androgens and spermatogenesis: lessons from transgenic mouse models  

UK PubMed Central (United Kingdom)

Transgenic mouse models have contributed considerably to our understanding of the cellular and molecular mechanisms by which androgens control spermatogenesis. Cell-selective ablation of the androgen...Full Text Available

2010-05-27

128

A Combination of Dual-mode 2,940 nm Er:YAG Laser Ablation with Surgical Excision for Treating Medium-sized Congenital Melanocytic Nevus  

UK PubMed Central (United Kingdom)

BackgroundThere are various treatment options for congenital melanocytic nevus (CMN), including surgical excision, dermabrasions, curettage, laser treatment, chemical peels and cryosurgery....Full Text Available

2009-05-01

129

'TT ( \\\\ b - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Inertial navigation error propagation. 153. 100. --. 8. GN-5. Hypersonic entry guidance techniques. 150. 100. 0.8. 9. FM-13. Ablation effects on hypersonic ...

130

sup 131 I treatment of thyroid papillary carcinoma in a patient with renal failure  

Energy Technology Data Exchange (ETDEWEB)

Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.

1990-12-15

131

Radiofrequency ablation of the gastrointestinal tract with a stent-like electrode: experimental study  

Energy Technology Data Exchange (ETDEWEB)

To assess the technical feasibility of a newly designed stent-like electrode in rabbits. A stent-like electrode was knitted from a single thread of nitinol wire and interconnected to a generator using similar wire. In order to gauge the extent of radiofrequency ablation (RFA), we measured the depth of the ablated area in cow liver using a combination of 180-sec time intervals and 20- watt power increments. For data processing, Cox regression analysis was used. RFA was also applied to the small intestine of rabbits using this stent-like electrode under six different sets of conditions: 10 watts for 1 min, 10 watts for 2 mins, 20 watts for 1 min, 20 watts for 2 mins, 30 watts for 1 min, and 30 watts for 2 mins. To determine the gross and microscopic findings, six animals were sacrificed immediately after the procedure and the results obtained under the different sets of conditions were correlated. Eight rabbits were monitored for 4 weeks prior to ...

2003-03-01

132

Endovenous radiofrequency ablation using stent-type electrode for varicose veins: an experimental study in goats  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to investigate the feasibility and the optimal conditions of radiofrequency (RF) ablation by using the stent-type electrode upon the saphenous vein of goats for the endovenous treatment of varicose veins. A self-expandable nitinol stent electrode (6 mm diameter, 2 cm length, cell size; 1.3 x 2 mm) was designed to expose the distal 1 cm segment to allow for contact with the venous wall. The proximal part of the electrode was connected to the RF generator by insulated copper wires located within the stent electrode introducer. Initially, to optimize the power setting, ablation of 6 saphenous veins in 3 goats was performed with power settings of 10, 20 and 30 W. Pull back rate of the electrode was 2 and 4 cm/min for each power level, respectively. The goats were sacrificed 4-6 weeks later and histologic examinations of the saphenous veins were done. For the second part of the experiment, RF ...

2004-10-15

133

Nephron-sparing percutaneous ablation of a 5 cm renal cell carcinoma by superselective embolization and percutaneous RF-ablation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report on the nephron-sparing, percutaneous ablation of a large renal cell carcinoma by combined superselective embolization and percutaneous radiofrequency ablation. Materials and Methods: A 5 cm renal cell carcinoma of a 43-year-old drug abusing male with serologically proven HIV, hepatitis B and C infection, who refused surgery, was superselectively embolized using microspheres (size: 500 - 700 {mu}m) and a platinum coil under local anesthesia. Percutaneous radiofrequency ablation using a 7F LeVeen probe (size of expanded probe tip: 40 mm) and a 200 Watt generator was performed one day after transcatheter embolization under general anesthesia. Results: The combined treatment resulted in complete destruction of the tumor without relevant damage of the surrounding healthy renal tissue. The patient was discharged 24 hours after RF ablation. No complications like urinary leaks or fistulas ...

2001-11-01

134

Symptomatic hepatic cyst in a child: treatment with single-shot injection of tetracycline hydrochloride  

Energy Technology Data Exchange (ETDEWEB)

The prevalence of hepatic cysts is 0.1% to 0.5% based on autopsy studies, and 2.5% based on US examinations. Percutaneous therapies are a new alternative to surgery. They include simple percutaneous aspiration, catheter drainage alone, and catheter drainage with sclerotherapy. We present an 11-year-old boy admitted to hospital because of abdominal pain. A diagnosis of simple hepatic cyst was made, which was treated with aspiration and tetracycline hydrochloride solution (5%) injection into the cystic cavity. Complete regression was seen on US and MRI examination at 3 months, with total collapse and deflation of the cyst. The cyst regressed totally, leaving a hyperechoic linear scar on US examination at 1 year. On the basis of the clinical and imaging results obtained, percutaneous sclerotherapy of hepatic cysts can be recommended as the treatment of choice and as a valid alternative to laparoscopy in children. (orig.)

2009-10-15

135

Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter related bloodstream infection in patients after haematopoietic stem cell transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.

2010-01-01

136

Ultra high vacuum test setup for electron gun  

Energy Technology Data Exchange (ETDEWEB)

Ultra High Vacuum (UHV) test setup for electron gun testing has been developed. The development of next generation light sources and accelerators require development of klystron as a radio frequency power source, and in turn electron gun. This UHV electron gun test setup can be used to test the electron guns ranging from high average current, quasi-continuous wave to high peak current, single pulse etc. An electron gun has been designed, fabricated, assembled and tested for insulation up to 80 kV under the programme to develop high power klystron for future accelerators. Further testing includes the electron emission parameters characterization of the cathode, as it determines the development of a reliable and efficient electron gun with high electron emission current and high life time as well. This needs a clean ultra high vacuum to study these parameters particularly at high emission current. The cathode emission current, work function and ...

2008-05-01

137

Time-varying magnetic fields increase cytosolic free Ca sup 2+ in HL-60 cells  

Energy Technology Data Exchange (ETDEWEB)

Electromagnetic fields have been reported to cause a variety of biological effects. It has been hypothesized that many of these phenomena are mediated by a primary effect on the concentration of cytosolic free calcium ((Ca2+)i). We investigated the effects of exposure to electromagnetic fields on (Ca2+)i in HL-60 cells using the Ca2(+)-sensitive fluorescent indicator indo-1. Indo-1-loaded cell samples were exposed to a radiofrequency electromagnetic field, a static magnetic field, and a time-varying magnetic field, which were generated by a magnetic resonance imaging (MRI) unit. We found that a 23-min exposure to all three fields, in combination, induced a significant increase in (Ca2+)i of 31 +/- 8 (SE) nM (P less than 0.01, n = 13) from a basal level of 121 +/- 8 nM. Also, cells exposed to only the time-varying magnetic field had a mean (Ca2+)i that was 34 +/- 10 nM (P less than 0.01, n = 11) higher than parallel control samples. Separate exposure to the ...

1990-10-01

138

Thermoregulatory responses of rats exposed to 9. 3-GHz radio-frequency radiation  

Energy Technology Data Exchange (ETDEWEB)

Ketamine-anesthetized Sprague-Dawley rats were exposed in H orientation to far-field 9.3-GHz continuous-wave (CW) and pulsed (2 microseconds 500 pps) radiofrequency radiation (RFR) at average power densities of 30 and 60 mW/sq. cm (whole-body average specific absorption rates of 9.3 and 18.6 W/kg, respectively). Irradiation was conducted to cyclicly increase colonic temperature from 38.5 to 39.5 C. Colonic, tympanic, and subcutaneous temperatures, ECG, blood pressure, and respiratory rate were continuously recorded during experimentation. At both power densities, the subcutaneous and tympanic temperature increases significantly exceeded the colonic temperature increase. At both exposure levels, heart rate increased significantly during irradiation and returned to baseline when exposure was discontinued. Blood pressure and respiratory rate did not significantly change during irradiation. There were no significant differences between the effects of CW and pulsed RFR exposure. The levels ...

1987-10-15

139

System control and data acquisition of the two new FWCD RF systems at DIII-D  

Energy Technology Data Exchange (ETDEWEB)

The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend the three branches together into one cohesive system. The control of the ...

1995-10-01

140

Structures and properties of fluorinated amorphous carbon films  

International Nuclear Information System (INIS)

Fluorinated amorphous carbon (a-C:F) films were deposited by radio frequency bias assisted microwave plasma electron cyclotron resonance chemical vapor deposition with tetrafluoromethane (CF_4) and acetylene (C_2H_2) as precursors. The deposition process was performed at two flow ratios R=0.90 and R=0.97, where R=CF_4/(CF_4+C_2H_2). The samples were annealed at 300 deg. C for 30 min. in a N_2 atmosphere. Both Fourier transform infrared and electron spectroscopy for chemical analyzer were used to characterize the a-C:F film chemical bond and fluorine concentration, respectively. A high resolution electron energy loss spectrometer was applied to detect the electronic structure. The higher CF_4 flow ratio (R=0.97) produced more sp"3 linear structure, and it made the a-C:F film smoother and softer. A lifetime of around 0.34 #mu#s and an energy gap of #approx#2.75 eV were observed in both the as-deposited and after annealing conditions. The short ...

2004-07-01

141

Smith-Purcell free-electron laser  

International Nuclear Information System (INIS)

The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these projects are using permanent magnet undulators to couple the electron beam with the ...

1995-08-21

142

Reduction of RF-sheaths potentials by compensation or suppression of parallel RF currents on ICRF antennas  

International Nuclear Information System (INIS)

Radio frequency (RF) sheaths are suspected of limiting the performance of present-day ion cyclotron range of frequencies (ICRFs) antennas over long pulses and should be minimized in future fusion devices. Within the simplest models, RF-sheath effects are quantified by the integral VRF = ? E|| ? dl where the parallel RF field E|| is linked with the slow wave. On 'long open field lines' with large toroidal extension on both sides of the antenna it was shown that VRF is excited by parallel RF currents j|| flowing on the antenna structure. In this paper, the validity of this simple sheath theory is tested experimentally on the Tore Supra (TS) ITER-like antenna prototype (ILP), together with antenna simulation and post-processing codes developed to compute VRF. The predicted poloidal localization of high-|VRF| zones is confronted to that inferred from experimental data analysis. Surface temperature distribution on ILP front face, as well as ...

2010-02-01

143

RF plasma nitriding of severely deformed iron-based alloys  

International Nuclear Information System (INIS)

The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the #alpha#-phase at the higher nitriding ...

2003-05-15

144

Measurement of magnetic fields in the Area Metropolitana  

International Nuclear Information System (INIS)

The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which were chosen because are areas with high population density and also in proximity to antennas that emit electromagnetic waves. Before carrying out the data collection ...

145

High-efficiency Resonant rf Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams  

Energy Technology Data Exchange (ETDEWEB)

High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast passage. We discuss the design of the spin rotator and describe two types of transmission-based neutron spin-flip efficiency ...

2008-08-01

146

Flexible organic electronic devices: Materials, process and applications  

Energy Technology Data Exchange (ETDEWEB)

The research for the development of flexible organic electronic devices (FEDs) is rapidly increasing worldwide, since FEDs will change radically several aspects of everyday life. Although there has been considerable progress in the area of flexible inorganic devices (a-Si or solution processed Si), there are numerous advances in the organic (semiconducting, conducting and insulating), inorganic and hybrid (organic-inorganic) materials that exhibit customized properties and stability, and in the synthesis and preparation methods, which are characterized by a significant amount of multidisciplinary efforts. Furthermore, the development and encapsulation of organic electronic devices onto flexible polymeric substrates by large-scale and low-cost roll-to-roll production processes will allow their market implementation in numerous application areas, including displays, lighting, photovoltaics, radio-frequency identification circuitry and chemical sensors, as well as to ...

2008-08-25

147

Electron cyclotron heating  

International Nuclear Information System (INIS)

Electron cyclotron resonance heating (ECH) in BPX is planned as a possible upgrade to supplement the baseline ion cyclotron resonance frequency (ICRF) system. Eventual implementation primarily depends on the development of the required source technology. ECH offers important technical advantages over ICRF: High radio-frequency (FR) power density can be transmitted through ports (P/A >#approx# 100 MW/M"2), and the antenna need not be in contact with the plasma for efficient coupling. In particular, low-field side, linearly polarized (O-mode) power injection will suffice. By controlling the N spectrum, or by steering the antenna, the power deposition profile can be controlled during ramping of the magnetic field even with a fixed frequency source. Because of the possibility of localized power deposition, ECH is a natural candidate for controlling magnetrohydrodynamic (MHD) activity. Sawtooth oscillations may be prevented by heating in the vicinity of the q = 1 ...

148

Copper coatings for minimization of retention and permeation of implanted tritium in aluminum alloy 6061  

Energy Technology Data Exchange (ETDEWEB)

Copper coatings deposited on Al-6061 substrates by radio frequency magnetron sputtering, to prevent the retention and permeation of energetically implanted tritium in Al-6061, were evaluated by a variety of characterization techniques. The coatings, weighing in the 0.03 to 0.088 kg/m{sup 2} range, were smooth and had a fine grain structure. They contained the intermetallic phases Cu{sub 9}Al{sub 4} and CuAl{sub 2} as well as copper. The fractions of Al and Cu in any coating increased and decreased, respectively, with increasing depth below the surface. Furthermore, the fractions of Al and Cu on the coating surface decreased and increased, respectively, with increasing coating weight. There was no texture or preferred orientation in the Cu phase of the coatings. A significant amount of oxygen was also detected at the original substrate surface. Residual stress measurements revealed that, in both Cu and CuAl{sub 2}, the stresses in the coating ...

1999-08-01

149

A simple 5-DoF MR-compatible motion signal measurement system.  

Science.gov (United States)

The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made ...

2011-09-01

150

Transbrachial arterial digital subtraction angiography  

International Nuclear Information System (INIS)

27 cases including 7 outpatients, underwent intraarterial DSA using 4-F nylon catheter, by transbrachial arterial approach. Much of DSAs were performed in Fuji Computed Radiography (FCR), which has high spatial resolution. In all cases, image quality satisfied clinical demands. No major complication occured in this series. Transbrachial arterial digital subtraction angiography is excellent and safe method for screening of vascular disease. (author).

1985-01-01

151

Scintigraphic assessment of pericardio-peritoneal window patency. Relevance to peritoneal dialysis.  

Science.gov (United States)

To alleviate recurrent pericardial effusion secondary to systemic lupus erythematosus, pericardio-peritoneal window was performed. Subsequently, end stage renal disease developed and the patient required peritoneal dialysis. Patency of the pericardio-peritoneal window was demonstrated by intraperitoneal injection of Tc-99m SC through a Tenckhoff catheter, which prompted special counsel to the patient in order to prevent infectious pericarditis potentially complicating peritoneal dialysis induced-peritonitis. PMID:7554664

1995-07-01

152

Radionuclide demonstration of ventriculoatrial shunt-cutaneous fistula with cerebrospinal fluid leak  

International Nuclear Information System (INIS)

Radionuclide techniques have commonly been used to assess ventriculovenous shunt function, cerebrospinal fluid dynamics, and for the diagnosis of cerebrospinal fluid leaks. All of these techniques were utilized in this unusual case of retrograde migration of a ventriculoatrial catheter into the neck, with cutaneous fistulization and CSF leak. (orig.).

153

Dose specification and quality assurance of RTOG protocol 95-17; a cooperative group study of 192Ir breast implants as sole therapy  

UK PubMed Central (United Kingdom)

PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available

2007-12-01

154

Clinical application of FCR for the portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-08-01

155

Clinical application of FCR for the portable chest radiographs in ICU  

International Nuclear Information System (INIS)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-01-01

156

The interaction of fast alpha particles with pellet ablation clouds  

International Nuclear Information System (INIS)

The energy spectra of energetic confined alpha particles are being measured using the pellet charge exchange method [R. K. Fisher, J. S. Leffler, A. M. Howald, and P. B. Parks, Fusion Technol. 13, 536 (1988)]. The technique uses the dense ablation cloud surrounding an injected impurity pellet to neutralize a fraction of the incident alpha particles, allowing them to escape from the plasma where their energy spectrum can be measured using a neutral particle analyzer. The signal calculations given in the above-mentioned reference disregarded the effects of the alpha particles' helical Larmor orbits, which causes the alphas to make multiple passes through the cloud. Other effects such as electron ionization by plasma and ablation cloud electrons and the effect of the charge state composition of the cloud, were also neglected. This report considers these issues, reformulates the signal level calculation, and uses a Monte-Carlo approach to calculate ...

157

Some properties of atomic beam produced by laser induced ablation of Li target  

International Nuclear Information System (INIS)

Pulsed atomic beams produced in vacuum by laser induced ablation from a lithium target are analyzed by laser induced fluorescence (LIF). The 1-mixing processes induced in the n = 9, 10 Li Rydberg states by collisions with CO_2 molecules illustrate the application of the method. Resolution is limited by the 1 mm diameter of the probe laser beam. Combining LIF and absorption measurements gives n_L_i as a function of time at various distances from the target surface. The investigation of the Li-C0_2 1-mixing process in a heat pipe oven proved impossible due to the high reactivity of Li with C0_2. This problem was solved by renewing the Li atoms at each laser shot. Values obtained for n = 9, n = 10 are k = 17 x 10"-"8 and 15 x 10"-"8 cc/sec, respectively.

158

Rapid and cost-effective assessment of connectivity among assemblages of Choerodon rubescens (Labridae), using laser ablation ICP-MS of sagittal otoliths  

British Library Electronic Table of Contents (United Kingdom)

A rapid and cost-effective assessment was required to provide advice to management on the connectivity between juvenile and adult life cycle stages of Baldchin Groper Choerodon rubescens, a labrid endemic to the west coast of Australia, which has high social value, but relatively low commercial fishery importance. To minimise costs we used laser ablation ICP-MS to analyse levels of a small suite of elements (Ca, Mg, Mn, Cu, Zn, Sr, Rb, Ba and Pb) at the margin (adult phase) and core (juvenile phase) of the same otoliths of adult C. rubescens, collected at ten locations in five management zones. The elemental composition of both otolith margins and cores differed significantly among management zones and in some cases among locations within zones. Similarity of the pattern of among-zone elem...

2011-01-01

159

Pulsed Radiofrequency Ablation for Residual and Phantom Limb Pain: A Case Series  

British Library Electronic Table of Contents (United Kingdom)

Abstract Residual limb pain (RLP) and phantom limb pain (PLP) can be debilitating and can prevent functional gains following amputation. High correlations have been reported between RLP and the stump neuromas following amputation. Many treatment methods including physical therapy, medications, and interventions, have been used with limited success. Pulsed radiofrequency ablation (PRFA) has shown promise in treating neuropathic pain because of the inhibition of evoked synaptic activity. We present 4 amputees who were treated with PRFA after failing conservative management for their RLP and PLP. All 4 patients underwent PRFA and demonstrated at least 80% relief of RLP for over 6 months. One patient reported a complete resolution of phantom sensation while another patient had significantly de...

2010-01-01

160

NONLINEAR OPTICAL PHENOMENA: Nonlinear optical properties of colloidal silver nanoparticles produced by laser ablation in liquids  

Science.gov (United States)

The optical and nonlinear optical properties of colloidal solutions of silver obtained by laser ablation in water and ethanol are studied. It is shown that freshly prepared colloids experience a full or partial sedimentation by changing their nonlinear optical properties. Aqueous colloids undergo a partial sedimentation and their nonlinear optical absorption changes to nonlinear optical transmission. The obtained results are interpreted using the Drude model for metal particles taking the particle size into account and can be explained by the sedimentation of larger silver particles accompanied by the formation of a stable colloid containing silver nanoparticles with a tentatively silver oxide shell. The characteristic size of particles forming such a stable colloid is determined and its optical nonlinearity is estimated.

2004-07-01

161

X-ray ablation measurements and modeling for ICF applications  

Energy Technology Data Exchange (ETDEWEB)

X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and hohlraum wall thickness are also described. ...

1996-09-01

162

Plasma lens formation in e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).

1995-02-01

163

Optimizing the Protocol for Pulmonary Cryoablation: A Comparison of a Dual- and Triple-Freeze Protocol  

International Nuclear Information System (INIS)

The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total freeze time (15 vs. 20 min), the ablation zone identified with the triple freeze-thaw protocol was not ...

2010-12-01

164

MMP-9 Gene Ablation and TIMP-4 Mitigate PAR-1-Mediated Cardiomyocyte Dysfunction: A Plausible Role of Dicer and miRNA  

UK PubMed Central (United Kingdom)

Although matrix metalloproteinase-9 (MMP-9) is involved in cardiomyocytes contractility dysfunction, tissue inhibitor of metalloproteinase-4 (TIMP-4) mitigates the effect of MMP-9, and proteinase-activated...Full Text Available

2010-07-01

165

Phenomenological studies on structure and elemental composition of nanosecond and femtosecond laser-generated aerosols with implications on laser ablation inductively coupled plasma mass spectrometry  

International Nuclear Information System (INIS)

In laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), the properties of laser-generated aerosols, such as size and composition, are crucial for matrix-independent quantification. In this study, the aerosol particle morphology and elemental composition generated by two state-of-the-art laser systems (ArF excimer nanosecond-UV laser and Ti:sapphire femtosecond-IR laser) were investigated by electron microscopic techniques. Electrostatic sampling of the aerosols directly onto transmission electron microscopy (TEM) grids allowed us to study the morphology and elemental composition of the aerosols using TEM and TEM-EDX (energy dispersive X-ray spectroscopy) analyses, respectively. The results of the electron microscopic studies were finally compared to the LA-ICPMS signals of the main matrix components. The investigations were carried out for non-conducting materials (glass and zircon), metallic samples (steel and brass) and semiconductors ...

166

RF plasma nitriding of severely deformed iron-based alloys  

Energy Technology Data Exchange (ETDEWEB)

The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10{sup -5} bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of {epsilon} and {gamma}' nitrides in the compound layer, with a preferential formation of {gamma}' at the expense of the {alpha}-phase at the ...

2003-05-15

167

Retrieval of intravascular foreign bodies with goose neck snare  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is ...

2004-03-01

168

Percutaneous drainage of abdominal abcess  

Energy Technology Data Exchange (ETDEWEB)

The mortality in undrained abdominal abscesses is high with a mortality rate ranging between 45 and 100%. The outcome in abdominal abscesses, however, has improved due to advances in image guided percutaneous interventional techniques. The main indications for the catheter drainage include treatment or palliation of sepsis associated with an infected fluid collection, and alleviation of the symptoms that may be caused by fluid collections by virtue of their size, like pancreatic pseudocele or lymphocele. The single liver abscesses may be drained with ultrasound guidance only, whereas the multiple abscesses usually require computed tomography (CT) guidance and placement of multiple catheters. The pancreatic abscesses are generally drained routinely and urgently. Non-infected pancreatic pseudocysts may be simply observed unless they are symptomatic or cause problems such as pain or obstruction of the biliary or the gastrointestinal tract. ...

2002-09-01

169

Opto-acoustic recanilization delivery system  

Energy Technology Data Exchange (ETDEWEB)

Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design approach incorporates the optical fibers into ...

2002-01-01

170

Combined peritoneography and computerized tomography for evaluating abdominal complications in patients undergoing continuous peritoneal dialysis  

International Nuclear Information System (INIS)

Continuous ambulatory peritoneal dialysis (CAPD) is a generally well-tolerated treatment. However, some patients exhibit such complications as to prevent the continuation of treatment. Peritonitis is the major problem, but the continuation of treatment may also be undermined by different complications, such as peritoneal leakage, hernia, catheter malfunctioning, and scrotal-penile edema; a careful investigation of the patient is always needed in such cases. From November 1985 to February 1990, we examined 20 patients, who had presented with different types of complications in the course of dialysis. Peritoneography demonstrated 3 cases of abdominal hernias, 2 cases of patency of the peritoneal-vaginal duct, and 2 cases of catheter obstruction. Peritoneal CT allowed the identification of leakage in 3 patients, while the combined use of the two techniques showed adhesions or pathologic peritoneal recesses in 7 cases. In 3 patients normal patterns ...

1985-11-01

171

In vitro examination of the visibility of 11 stent catheters with real-time MR imaging; In-vitro-Untersuchung der Sichtbarkeit von 11 Stentkathetern unter Echtzeit-MR-Kontrolle  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an evaluation of the visibility of the tip of the stent-catheter and ...

2004-09-01

172

The usefulness of CO_2 indirect portography in transjugular intrahepatic portosystemic shunt(TIPS)  

International Nuclear Information System (INIS)

To determine the usefulness of carbon dioxide(CO_2) indirect portography during TIPS procedure. We evalvated eight patients who had undergone TIPS due to variceal hemorrhage or ascites caused by portal hypertension. All patients but one with complete situs inversus underwent wedged right hepatic venography for visualization of the portal vein using CO_2. For CO_2 indirect portal venography, 50cc of CO_2 was injected by hand without prior injection of a small amount of CO_2. In three patients a 5-F angiographic catheter was wedged into the right hepatic vein, and in the other five a 9-F sheath from a Ring's transjugular access set was adjunctively wedged into the right hepatic vein over the 5-F catheter. The time required for portal vein puncture was defined as the time between the indirect portal venography procedure and the first procedure after successful portal vein puncture. All patients successfully underwent TIPS without any immediate ...

1999-11-01

173

Hyperthermia in the Treatment of Cholangiocarcinoma: Development and Testing of an Endobiliary Microwave Device  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to create, perfect and test a hyperthermia balloon catheter for local treatment of cholangiocarcinoma. The device should induce hyperthermia in tumor tissue by acting locally in the bile duct lumen in contact with the tumor-infiltrated duct wall. In addition, it should exert tissue compression to cause an appreciable reduction in tumor microvasculature flow, thus improving thermal performance. Methods: According to the design specifications, the working temperature range should allow the device to be used for hyperthermia therapy either in combination with radiation and/or chemotherapy(radio/chemo-sensitizing effect at 42-45 deg. C) or alone (induction of coagulation necrosis above 65 deg. C). The balloon serves as an anchoring system during treatment and as a functional element to induce tissue compression. In vitro mechanical evaluation of the pressure/volume relationship, with the balloon inside rigid walled conduits, was ...

2003-08-01

174

The surface modification of tooth dentine with a Free Electron Laser (FEL)  

International Nuclear Information System (INIS)

Free Electron Laser (FEL) with the wide wavelength tunability has been developed and used for various applications. The FEL gives high efficiency for the photo-induced ablation when the laser is tuned to an absorption maximum of the target. The FEL was tuned to 9.4 #mu#m, which is an absorption maximum of phosphoric acid ion, a known major component of dentine. The FEL pulse length was several ps. The average output power was varied from 5 to 20 mW by filters. The change of irradiated dentine surface was analyzed by mass spectroscopy and Energy Dispersive X-ray (EDX) spectroscopy. Positive ions which correspond to Na"+, CO_3"+ and many phosphoric acid ions were measured. It was found that atomic ratio of P/Ca had reduced from 0.65-0.60. The atomic ratio of P/Ca, however had not changed with irradiation by Er:YAG laser (2.9 #mu#m), or CO_2 laser (10.6 #mu#m). These results indicate the selective ablation of phosphoric acid ion by the 9.4 mm FEL ...

1998-09-02

175

Selective absorption of ultraviolet laser energy by human atherosclerotic plaque treated with tetracycline  

Energy Technology Data Exchange (ETDEWEB)

Tetracycline is an antibiotic that absorbs ultraviolet light at 355 nm and preferentially binds to atherosclerotic plaque both in vitro and in vivo. Tetracycline-treated human cadaveric aorta was compared with untreated aorta using several techniques: absorptive spectrophotometry; and tissue uptake of radiolabeled tetracycline, which showed 4-fold greater uptake by atheroma than by normal vessel. In addition, intravenous tetracycline administered to patients undergoing vascular surgery demonstrated characteristic fluorescence in surgically excised diseased arteries. Because of tetracycline's unique properties, the authors exposed tetracycline-treated and untreated aorta to ultraviolet laser radiation at a wavelength of 355 nm. They found enhanced ablation of tetracycline-treated atheroma compared with untreated atheroma. The plaque ablation caused by ultraviolet laser radiation was twice as extensive in tetracycline-treated vs ...

1985-05-01

176

Cells producing insulin-like androgenic gland hormone of the giant freshwater prawn, Macrobrachium rosenbergii, proliferate following bilateral eyestalk-ablation  

British Library Electronic Table of Contents (United Kingdom)

We found that the androgenic gland (AG) of Macrobrachium rosenbergii possesses three cell types. Type I cells are small polygonal shaped-cells (13.4 mu m in diameter), stain strongly with hematoxylin-eosin (H&E), have abundant multilayered rough endoplasmic reticulum (rER), and nuclei containing mostly heterochromatin. Type II cells are slightly larger (18.6 mu m in diameter), stain lightly with H&E, have rER with dilated cisternae, and nuclei containing mostly euchromatin. Type III cells (previously undescribed) are similar in size and shape to type I cells, but the cytoplasm is unstained and they have a high amount of smooth endoplasmic reticulum (sER) and mitochondria with tubular cristae. Bilateral eyestalk-ablation resulted in AG hypertrophy with a proliferation and predominance of ty...

2011-01-01

177

Uranium isotopic assay instrument  

International Nuclear Information System (INIS)

Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and absorbance. Isotopically selective excitation of uranium vapor also ...

2006-10-16

178

Nondestructive transfer of complex molecular systems of various origins into aerosol phase by means of submillimeter irradiation of free-electron laser (FEL) of the Siberian center for photochemical research  

International Nuclear Information System (INIS)

Original investigations of ablation of minerals, fullerene-like compounds, polymers and complicated biological macromolecules under the action of submillimeter radiation of the free-electron laser (FEL) developed and built at Budker Institute of Nuclear Physics [V.P. Bolotin et al., First experiments on high-power Novosibirsk terahertz free-electron laser, Budker INP, 2005, p. 37 [1

2007-05-21

179

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures  

International Nuclear Information System (INIS)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...

1999-12-01

180

Method for the approximate solution of a two-phase stefan problem with reverse motion of the front  

Science.gov (United States)

Determination of the trajectory of a phase transition front moving in a forward or reverse direction is reduced to the solution of an ordinary differential equation. A numerical check of the results shows the method to be highly accurate. The method was used recently over a period of several years to solve various problems connected with the thawing of frozen rocks and their refreezing; among the problems considered was that of the ablation of rocks during the channeling of well, in which the method invariably proved its effectiveness. This furnishes a basis for recommending it for broader usage.

1988-03-01

181

Local ablading therapy methods in case of liver metastases of colorectal carcinoma; Lokal abladierende Therapieverfahren bei Lebermetastasen kolorektaler Karzinome  

Energy Technology Data Exchange (ETDEWEB)

Clinical studies have proved the effectiveness of local ablading methods in pations with non-resectable liver metastases of a colorectal carcinoma. RF ablation and LITT are a potentially curative therapy option and an alternative to systemic chemotherapy; the latter is carried out primarily for reducing tumour size with the goal of secondary resectability. The number of R0-sesectable metastases can be enhanced by a combined therapy of surgery and local ablading methods, e.g. by preoperative, intraoperative or postoperative ablasion of further non-resectable tumours during surgery. Systemic chemotherapy combined with surgery as an adjuvant method is not recommended unless in cases of non-abladable tumour recidivation. Currently, systemic chemotherapy is used as a neo-adjuvant therapy for tumour size reduction with the goal of secondary resectability or, in case of inoperability, local ablation. (orig.) [German] Abladierende Verfahren. Klinische ...

2003-03-01

182

Radiofrequency Ablation of Intrahepatic Cholangiocarcinoma: Preliminary Experience  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 months thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two ...

2010-08-01

183

Heteroepitaxial growth of In-face InN on GaN (0001) by plasma-assisted molecular-beam epitaxy  

International Nuclear Information System (INIS)

The thermodynamic aspects of indium-face InN growth by radio frequency plasma-assisted molecular-beam epitaxy (rf-MBE) and the nucleation of InN on gallium-face GaN (0001) surface were investigated. The rates of InN decomposition and indium desorption from the surface were measured in situ using reflected high-energy electron diffraction and the rf-MBE 'growth window' of In-face InN (0001) was identified. It is shown that sustainable growth can be achieved only when the arrival rate of active nitrogen species on the surface is higher than the arrival rate of indium atoms. The maximum substrate temperature permitting InN growth as a function of the active nitrogen flux was determined. The growth mode of InN on Ga-face GaN (0001) surface was investigated by reflected high-energy electron diffraction and atomic force microscopy. It was found to be of the Volmer-Weber-type for substrate temperatures less than 350 deg. C and of the ...

2005-06-01

184

Fermilab Steering Group Report  

Energy Technology Data Exchange (ETDEWEB)

The Fermilab Steering Group has developed a plan to keep U.S. accelerator-based particle physics on the pathway to discovery, both at the Terascale with the LHC and the ILC and in the domain of neutrinos and precision physics with a high-intensity accelerator. The plan puts discovering Terascale physics with the LHC and the ILC as Fermilab's highest priority. While supporting ILC development, the plan creates opportunities for exciting science at the intensity frontier. If the ILC remains near the Global Design Effort's technically driven timeline, Fermilab would continue neutrino science with the NOVA experiment, using the NuMI (Neutrinos at the Main Injector) proton plan, scheduled to begin operating in 2011. If ILC construction must wait somewhat longer, Fermilab's plan proposes SNuMI, an upgrade of NuMI to create a more powerful neutrino beam. If the ILC start is postponed significantly, a central feature of the proposed Fermilab plan calls for building ...

2007-01-01

185

Simulation-based training improves applied clinical placement of ultrasound-guided PICCs  

British Library Electronic Table of Contents (United Kingdom)

Purpose Skilled placement of peripherally inserted central catheters (PICC) has a profound impact on patient well-being and costs of care. The use of ultrasound-guided methods and prescribed training for cannulation skills are evidence-based practice recommendations. The purpose of this study was to compare two methods of PICC instruction on the acquisition of applied skills. Methods Residents were randomly assigned to one of two groups (N?=?16/16) of this blind-rater study and were trained to perform ultrasound-guided PICC cannulation using either simulation or apprenticeship methods. All residents were assessed placing a PICC in applied clinical patient care. Results Residents who completed simulation training had significantly better transfer of skills to applied clinical practice than ...

2011-01-01

186

Improving functional esophageal surgery with a ?smart? bougie: endoflip  

British Library Electronic Table of Contents (United Kingdom)

Background An emerging imaging tool, the functional lumen imaging probe (Endoflip; Crospon Ltd, Galway, Ireland), provides a real-time measurement of esophagogastric junction (EGJ) capacity and diameter, which would be of particular interest in functional esophageal surgery such as Heller myotomy and antireflux procedures. This study aimed to demonstrate the intraoperative use of endoflip in the treatment of achalasia and gastroesophageal reflux disease (GERD). Methods In the first case, Heller myotomy was performed under endopflip guidance, for persistent dysphagia after failed endoscopic dilatation. In the second case, the endoflip was used to calibrate a Nissen fundoplication. With the patient under general anesthesia, the endoflip catheter was inserted orally and positioned to straddle...

2011-01-01

187

Hemidiaphragmatic paralysis in preterm neonates: a rare complication of peripherally inserted central catheter extravasation  

British Library Electronic Table of Contents (United Kingdom)

Unilateral diaphragmatic paralysis was diagnosed in 2 preterm neonates born at 29 and 25 weeks of gestation, respectively. In both instances, the pathophysiology was phrenic nerve injury after extravasation of parenteral nutrition fluid. Misplacement and infection were predisposing factors. Diaphragmatic movement analysis by time-motion-mode ultrasonography was helpful in achieving a diagnosis. The first neonate required a diaphragmatic placation, whereas the other infant was managed nonoperatively. These cases confirm a rare etiology of diaphragmatic paralysis and possible spontaneous recovery. In neonates with very low birth weight, general anesthesia and thoracic surgery may be associated with a high morbidity, suggesting that nonoperative medical treatment, when possible, is preferable...

2011-01-01

188

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-12-01

189

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

International Nuclear Information System (INIS)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-01-01

190

Balloon dilatation and balloon-expandable stents for PTA of proximal venous stenoses in haemodialysis patients. Dilatation und ballonexpandierbare Stents zur Therapie zentralvenoeser Stenosen bei Dialysepatienten  

Energy Technology Data Exchange (ETDEWEB)

On 10 dialysis patients we performed 12 balloon dilatations, 2 catheter lyses, 6 stent implants (Palmaz stent) and one atherectomy of central venous stenoses or occlusions (v. subclavia, v. brachiocephalica) at the shunt arm of the patient. The primary success rate was, in balloon PTA and lysis, 12/14 interventions, and in stent placement and atherectomy 7/7. The angiographical and clinical primary result after stent implantation was significantly better than after conventional dilatation. After 66% of the balloon dilatations recidivation occurred within the first year; this can be treated by means of repeated PTA. Whether long-term exclusion of recurrence can be achieved by stent implantation, must be established by means of follow-up studies that are at present in progress. (orig.).

1990-09-01

191

Glue embolization of aneurysm after stenting in canine carotid arteries-technical feasibility  

International Nuclear Information System (INIS)

Coiling or infusion of embolic materials into a wide necked aneurysm can be performed with stenting. The purpose of our study is to assess the technical feasibility of aneurysm treatment with glue embolization after stenting. We used four Wallstents for surgically repairing eight canine carotid aneurysms. After confirmation of the aneurysms on the angiogram, we introduced a 6-7 F guiding catheter in order to deploy the stents. After stenting, we passed a microcatheter into the aneurysm lumen through the stent mesh. 28% glue was slowly injected until the glue cast completely filled the lumen. We evaluated the passage of a microcatheter through the stent meshwork, formation of the glue cast and the stents' ability to protection for any leakage of glue. The follow-up angiogram was obtained for two dogs, one to three times until 8 weeks, and then we sacrificed the dogs and performed pathologic examinations. Stenting was successful in all cases except one in which the ...

2004-10-01

192

Percutaneous US-guided RF thermal ablation for malignant renal tumors: preliminary results in 13 patients  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive treatment for small renal cell carcinoma (RCC) can be necessary in selected patients and, anyway, is desirable. In situ ablation techniques, including RFA, have been developed. The aim of this study is to evaluate the feasibility, safety and short-term local effectiveness of percutaneous US-guided RFA in a small series, as well as mid-term patient outcome. Thirteen patients with a total of 18 tumors (17 small lesions, 35 mm in size or less, and a larger one, 75 mm in size) underwent 19 RFA sessions. Seven patients had a solitary kidney, and three suffered from VHL disease, too. We treated four lesions in a patient with a bilateral tumor. In another patient, three lesions were ablated. Seventeen tumors were RCC; one was a metastasis from lung cancer. Eight lesions were parenchymal, six exophytic, two parenchymal/exophytic, one parenchymal/central and one central. A monopolar RF system with multitined expandable electrode ...

2004-12-01

193

Thulium laser resection via a flexible cystoscope for recurrent non-muscle-invasive bladder cancer: initial clinical experience  

British Library Electronic Table of Contents (United Kingdom)

OBJECTIVE To present our initial experience of thulium laser resection via a flexible cystoscope for recurrent non-muscle-invasive bladder cancer (ThuRBT), as transurethral resection for bladder tumour (TURBT) is regarded as the reference standard for treating this disease, but alternative laser resection or ablation is suitable especially for recurrent tumours. PATIENTS AND METHODS From January 2005 to October 2005, 32 patients with early recurrent bladder tumour (recurrent within a year after TURBT) were treated with ThuRBT via a flexible cystoscope. The follow-up included urine analysis, ultrasonography and cystoscopy every 3 months. RESULTS All patients were treated successfully with ThuRBT in one session, with no bladder haemorrhage, obturator nerve reflex or vesicle perforation. Rand...

2008-01-01

194

Spectroscopic measurement of the Doppler broadening region of He II line emission of DT plasmas using impurity pellets  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of spectroscopic measurement of the velocity distribution of alpha particle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alpha particle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alpha particles was observed, even when boron pellets were injected. (orig.) 4 refs.

1997-03-01

195

Pulsed laser deposition of titanium-carbonitride thin films  

Energy Technology Data Exchange (ETDEWEB)

The goal of this research program is to determine whether pulsed laser deposition is an effective alternative method for growing TiCN thin films. Pulsed laser deposition (PLD) is chosen because of its well-documented capability for growing uniform, stoichiometric films in ultra-high vacuum or gaseous environments. Processing of thin films by PLD is also achieved at relatively low temperatures compared with CVD processing. Given these attributes, the primary objectives in this article are to determine whether nitrogen may be readily incorporated into films resulting from the laser-ablation of TiC in an N{sub 2} environment, determine what effect nitrogen has on mechanical properties, and determine whether nitrogen incorporation is strongly influenced by processes unrelated to laser deposition (e.g., thermally-activated surface reactions).

1997-05-15

196

Modeling of ablation by photospallation using the computer program PUFF/DFRACT  

Energy Technology Data Exchange (ETDEWEB)

In general, macroscopic material failure is a manifestation of irreversible changes at the microscopic level. Many tissues, which may appear to be macroscopically homogeneous, are, at a fundamental microscopic level, a composite material. For example, cornea is composed of a hyaluronic acid matrix in which layers of collagen fibers are overlaid in a crossing pattern. The points where the collagen fibers intersect are potential nucleation sites for microscopic defects, which under the action of tensile stress, nucleate, grow and coalesce to form macroscopic failure planes, or spall planes. Using a model based on microstructural evolution, this paper examines the failure process during photoablation. Specifically, the paper describes a physically motivated, micromechanical model based on the nucleation and growth of spherical voids. This model is then used to simulate photoablation of cornea. Potential for using this model to predict the stress wave and material damage measured by ...

1995-03-01

197

Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases  

British Library Electronic Table of Contents (United Kingdom)

Objective To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Methods Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4?mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Results Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients w...

2008-01-01

198

Free-electron-laser-induced shock-wave control and mechanistic analysis using pulse control  

International Nuclear Information System (INIS)

The wavelength of the free electron laser (FEL) in Osaka University can be continuously varied in the range of 5.0-20.0 #mu#m. The FEL has a double-pulse structure, consisting of a train of macropulses of pulse duration 12 #mu#s. Each macropulse contains a train of 330 micropulses of pulse duration 5 ps. The tunability and picosecond pulses afford new medical and biological applications. However, a macropulse of long pulse duration leads to undesirable secondary effects. Precise control of the macropulse duration is essential for the high-precision applications of the FEL. An FEL pulse control system using acousto-optic modulators has been developed to investigate mechanical (shock-wave) effects of the FEL on living tissues. With this system, we have controlled photoinduced shock waves and determine the mechanism of interaction during FEL-induced tissue ablation.

2008-11-01

199

Effect of Heart Rate on Ventricular Repolarization in Healthy Individuals Applying Vectorcardiographic T Vector and T Vector Loop Analysis  

British Library Electronic Table of Contents (United Kingdom)

Background: Ventricular repolarization (VR) is strongly influenced by heart rate (HR) and autonomic nervous activity, both of which also are important for arrhythmogenesis. Their relative influence on VR is difficult to separate, but might be crucial for understanding while some but not other individuals are at risk for life-threatening arrhythmias at a certain HR. This study was therefore designed to assess the -pure- effect of HR increase by atrial pacing on the ventricular gradient (VG) and other vectorcardiographically (VCG) derived VR parameters during an otherwise unchanged condition. Methods: In 19 patients with structurally normal hearts, a protocol with stepwise increased atrial pacing was performed after successful arrhythmia ablation. Conduction intervals were measured on averag...

2011-01-01

200

Detection of previous neutron irradiation and reprocessing of uranium materials for nuclear forensic purposes  

International Nuclear Information System (INIS)

The paper describes novel analytical methods developed for the detection of previous neutron irradiation and reprocessing of illicit nuclear materials, which is an important characteristic of nuclear materials of unknown origin in nuclear forensics. Alpha spectrometry and inductively coupled plasma sector-field mass spectrometry (ICP-SFMS) using solution nebulization and direct, quasi-non-destructive laser ablation as sample introduction were applied for the measurement of trace-level "2"3"2U, "2"3"6U and plutonium isotopes deriving from previous neutron irradiation of uranium-containing nuclear materials. The measured radionuclides and isotope ratios give important information on the raw material used for fuel production and enable confirm the supposed provenance of illicit nuclear material.

2009-04-01

201

Cytoplasmic p63 immunohistochemistry is a useful marker for muscle differentiation: an immunohistochemical and immunoelectron microscopic study  

British Library Electronic Table of Contents (United Kingdom)

TP63, a member of the TP53 gene family, is a nuclear marker of myoepithelial cells. Antibody against p63 is frequently used to aid in the diagnosis of prostate carcinoma, as well as in the identification of myoepithelial cells in other tissues including the breast. p63 is also a marker for squamous cell carcinoma. Recently, it was found that all p53 family members are involved in regulating the process of muscle differentiation through the retinoblastoma (RB) protein. Ablation of these p53 family functions blocks the differentiation program and promotes malignant transformation by enabling cooperating oncogenes to transform myoblasts. We therefore studied p63 expression in a number of neoplasms with myogenic differentiation. Immunohistochemical staining for p63 was performed on paraffin se...

2011-01-01

202

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.

203

On the Utility of Antiprotons as Drivers for Inertial Confinement Fusion  

Energy Technology Data Exchange (ETDEWEB)

By contrast to the large mass, complexity and recirculating power of conventional drivers for inertial confinement fusion (ICF), antiproton annihilation offers a specific energy of 90MJ/{micro}g and thus a unique form of energy packaging and delivery. In principle, antiproton drivers could provide a profound reduction in system mass for advanced space propulsion by ICF. We examine the physics underlying the use of antiprotons ({bar p}) to drive various classes of high-yield ICF targets by the methods of volumetric ignition, hotspot ignition and fast ignition. The useable fraction of annihilation deposition energy is determined for both {bar p}-driven ablative compression and {bar p}-driven fast ignition, in association with 0-D and 1-D target burn models. Thereby, we deduce scaling laws for the number of injected antiprotons required per capsule, together with timing and focal spot requirements. The kinetic energy of the injected antiproton beam required to ...

2003-10-20

204

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. Our results show that a treatment planning ...

2001-02-01

205

Usefulness of thromboaspiration with Desilets-Hoffman sheath in thrombosed hemodialysis access graft  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to evaluate the feasibility, efficacy and safety of percutaneous thromboaspiration with a Desilets-Hoffman Sheath compared with the previously established percutaneous mechanical thrombectomy technique in cases of occluded dialysis graft. One hundred and sixty eight patients (103 women, 65 men; mean age, 54.7 years; mean graft age, 20.9 months) with 225 episodes of dialysis graft thrombosis underwent percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath using the crossing catheter or single puncture technique. The technical success rate, procedure time, and complication and patency rates were analyzed. Technical success was achieved in 200 of the 225 procedures (88.9%). The average duration of the intervention was 74.3 {+-} 35 minutes. The primary patency rate was 63.1% at 3 months, 44.2% at 6 months and 26.3% at 1 year. Major complications occurred in 4% of the cases (4 venous ruptures; 4 arterial embolisms; 1 arterial ...

2004-07-01

206

Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System  

Energy Technology Data Exchange (ETDEWEB)

RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified ...

1998-01-16

207

Modified nasolacrimal duct stenting  

International Nuclear Information System (INIS)

Objective: Traditional nasolacrimal duct stenting possesses some shortcoming including difficulty of pulling ball head guide wire from the nasal cavity with turbinate hypertrophy and nasal septal deviation. The new method of nose-oral tube track establishment can overcome the forementioned and increase the successful rate. Methods: 5 F catheter and arterial sheath were modified to be nasolacrimal duct stent delivery device respectively. Antegrade dacryocystography was taken firstly to display the obstructed site and followed by the modified protocol of inserting the guide wire through nasolacrimal duct and nasal cavity, and establishing the stent delivery track for retrograde stent placement. Results: 5 epiphora patients with failure implantation by traditional method were all succeeded through the modified stenting (100%). During 6-mouth follow-up, no serious complications and reocclusion occurred. Conclusion: The establishment of eye-nose-mouth-nose of external ...

2008-06-01

208

Dosimetry characterization of $^{32}$P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4  

CERN Document Server

Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for GEANT4. For the unsheathed 20 mm source these values were $0.2908 \\pm 0.0009$ cGy s$^{-1}$ mCi$^{-1}$ and $0.311 \\pm 0.001$ cGy ...

2003-01-01

209

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern film-screen systems. As a ...

210

Argentinian doctors accused of spreading AIDS.  

Science.gov (United States)

The provincial ministry of health has taken over a dialysis center in La Plata, Argentina, following the discovery that at least 20 of the clinic's 34 regular patients have been infected with the human immunodeficiency virus (HIV). Catheters of the clinic's dialysis machines were found to be contaminated with HIV. The 5 physicians associated with the Centro Modelo de Dialisis have been discharged for negligence. 20 of the regular patients also contracted hepatitis C. Argentinian law stipulates that filters for the same patient must be changed after 4 times and prohibits the use of the same vessel to administer medication to more than 1 patient. Testimony from nurses at the La Plata clinic revealed that filters were reused for several patients and basic sanitary procedures were not followed. In 1990, 33 kidney disease patients at a dialysis center in Cordoba became infected with HIV and it was discovered that filters had been used up to 8 times for different ...

1993-09-01

211

Application of a beta microprobe for quantification of regional cerebral blood flow with {sup 15}O-water and PET in rhesus monkeys  

Energy Technology Data Exchange (ETDEWEB)

A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g (PaCO{sub 2}=46.3 mmHg). ...

1998-02-01

212

Structural transformations in Sc/Si multilayers irradiated by EUVlasers  

Energy Technology Data Exchange (ETDEWEB)

Multilayer mirrors for the extreme ultraviolet (EUV) are keyelements for numerous applications of coherent EUV sources such as newtabletop lasers and free-electron lasers. However the field ofapplications is limited by the radiation and thermal stability of themultilayers. Taking into account the growing power of EUV sources thestability of the optics becomes crucial. To overcome this problem it isnecessary to study the degradation of multilayers and try to increasetheir temporal and thermal stability. In this paper we report the resultsof detailed study of structural changes in Sc/Simultilayers when exposedto intense EUV laser pulses. Various types of surface damage such asmelting, boiling, shockwave creation and ablation were observed asirradiation fluencies increase. Cross-sectional TEM study revealed thatthe layer structure was completely destroyed in the upper part ofmultilayer, but still survived below. The layers adjacent tothe substrateremained intact even ...

2007-08-21

213

Radiofrequency ablation of hepatocellular carcinoma extended into the portal vein: Preliminary results  

British Library Electronic Table of Contents (United Kingdom)

SommarioScopo In questo studio riportiamo i dati relativi all'ablazione percutanea con Radiofrequenza (RF) di HCC e trombosi neoplastica dei vasi portali. Pazienti e metodi Dieci pazienti (pz) cirrotici, 7 maschi e 3 femmine, eta media 68 anni, con 10 noduli di HCC e trombosi neoplastica dei vasi portali sono stati sottoposti ad ablazione percutanea con RF del trombo neoplastico e dell'HCC. La RF veniva ritenuta efficace quando alla TC con mdc si osservava la necrosi completa dell'HCC e al Color Doppler si osservava la ricanalizzazione completa dei vasi portali. Risultati La necrosi completa dell'HCC e la ricanalizzazione completa dei vasi portali si osservava in 7 (70%) dei 10 pazienti. Nei rimanenti 3 (30%) la necrosi dell'HCC e la ricanalizzazione dei vasi portali non risultavano comple...

2009-01-01

214

Pancreatic endocrine tumours: an out-matching field of cooperation with nuclear medicine; Les tumeurs endocrines du pancreas: un domaine privilegie de la cooperation avec la medecine nucleaire  

Energy Technology Data Exchange (ETDEWEB)

The Zollinger-Ellison syndrome (ZES) is taken as an example of the diagnostic and therapeutic strategy in gastro-entero-pancreatic endocrine tumours, given the standard characteristics of this procedure, whatever the nature of the primitive tumour. Management of ZES includes: anatomical localization of gastrinoma and of possible metastases, in 60 % of cases this step conditioning therapeutic indications and chances of cure; search of a type 1-multiple endocrine neoplasia (MEN A), in 25 % of cases; therapeutic indications: ablative surgery with curative intent in case of gastrinoma and of resectable liver metastases, palliative treatment otherwise: anti-secretory drugs, somatostatin analogues, chemotherapy and interferon {alpha}; long-term follow-up of patients with resected tumour. At each step, somatostatin receptor scintigraphy with indium 111-pentetreotide does play a pivotal role. (author). 110 refs.

1996-12-31

215

In-plane aligned CeO[sub 2] films grown on amorphous SiO[sub 2] substrates by ion-beam assisted pulsed laser deposition  

Energy Technology Data Exchange (ETDEWEB)

Both (001)- and (111)-oriented CeO[sub 2] thin films have been grown on amorphous fused silica (SiO[sub 2]) substrates by ion-beam assisted pulsed laser ablation of a polycrystalline CeO[sub 2] target. Using 200 eV Ar[sup +] ions incident at 55[degree] to the substrate normal, the preferred orientation for CeO[sub 2] film growth is (001) at room temperature, but changes to (111) for temperatures [ge]300 [degree]C. Furthermore, the ion-beam assisted CeO[sub 2] films exhibit strong in-plane crystallographic alignment. In contrast, CeO[sub 2] films grown without ion-beam assistance exhibit a mixture of polycrystalline orientations with the relative amounts depending on growth temperature. Under optimum conditions, off-normal-incidence Ar[sup +] ions produce a (111)-oriented crystalline CeO[sub 2] film that is aligned with respect to a single in-plane axis, on an amorphous substrate.

1994-10-17

216

High tunability of pulsed laser deposited Ba0.7Sr0.3TiO3 thin films on perovskite oxide electrode  

British Library Electronic Table of Contents (United Kingdom)

Ferroelectric thin films such as BST, PZT and PLZT are extensively being studied for the fabrication of DRAMS since they have high dielectric constant. The large and reversible remnant polarization of these materials makes it attractive for nonvolatile ferroelectric RAM application. In this paper we report the characterization of Ba0.7Sr0.3TiO3 (BST) thin films grown by pulsed laser ablation on oxide electrodes. The structural and electrical properties of the fabricated devices were studied. Growth of crystalline BST films was observed on La0.5Sr0.5CoO3 (LSCO) thin film electrodes at relatively low substrate temperature compared to BST grown on PtSi substrates. Electrical characterization was carried out by fabricating PtSi/LSCO/BST/LSCO heterostructures. The leakage current of the heteros...

2011-01-01

217

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...

2008-07-01

218

Deposition of NbTe{sub x} thin films using laser ablation: Crystallographic structure and spatial composition of deposits  

Energy Technology Data Exchange (ETDEWEB)

Pulsed laser deposition (PLD) is known for its capacity to reproduce a target composition on a substrate. The authors have used this deposition technique to produce thin films of transition metal chalcogenides. However, the deposits were always deficient in Te relative to the starting material (composed by a refractory metal (niobium) and a chalcogene (tellurium)). Variations of the interreticular distances have been observed with respect to fluence and substrate temperature. The authors show that spatial composition of the films is determined by a degree of crystallinity of deposit and by the reaction of formation of Te{sub 2} molecule within laser induced plume. Two kinds of deposits have been obtained: Nb{sub 5}Te{sub 4}-type thin films which have a one-dimensional structure and NbTe{sub 2}-type thin films which have a two-dimensional structure. While NbTe{sub 2} films have been realized by sputtering, it is the first time that Nb{sub 5}Te{sub 4} films have been deposited.

1996-12-31

219

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...

2010-01-15

220

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

International Nuclear Information System (INIS)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous plasma, thin ...

2010-01-01

221

Born-Oppenheimer breakdown effects and hyperfine structure in the rotational spectrum of strontium monosulfide, SrS  

Energy Technology Data Exchange (ETDEWEB)

A newly constructed Fourier transform microwave spectrometer has been used to record the pure rotational spectra of four isotopomers of SrS ({sup 88}Sr{sup 32}S, {sup 87}Sr{sup 32}S, {sup 86}Sr{sup 32}S, and {sup 88}Sr{sup 34}S) between 6 and 26 GHz. The molecules were produced by reacting laser ablated strontium with carbonyl sulfide (0.1% in argon). Pure rotational transitions in the ground, first and second vibrational states have been observed. The data set has enabled a multi-isotopomer fit. Born-Oppenheimer breakdown terms for both atoms have been determined. The {sup 87}Sr nuclear quadrupole coupling constant in {sup 87}Sr{sup 32}S has been determined for the first time.

2007-12-06

222

Application of spectroscopic techniques for the study of paper documents: A survey  

International Nuclear Information System (INIS)

For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: Fourier-Transform Infrared spectroscopy, Raman spectroscopy, Nuclear Magnetic ...

2009-06-01

223

An investigation of the production of thin films of some materials which undergo phase transitions for optical applications  

CERN Document Server

The aim of this work was to study the possibility of producing a fast switching optical thin film device to react to laser radiation in the visible/near infrared region of the spectrum. The switching mechanism was to be thermally driven. A computer program was written to enable the effects of changes of the refractive index of a component of a multilayer thin film stack to be modelled. Attempts to use the phase transition in vanadium dioxide were unsuccessful because, in the spectral region of interest, the 'open-state' absorption was too great. A class of materials known as 'the bronzes' was identified as being potentially useful. Attempts were made to produce thin films of bronze compounds of vanadium, tungsten and molybdenum by the techniques of conventional thermal evaporation and laser ablation for further studies. The former technique appeared to suffer from problems of decomposition of the source material. The latter technique showed greater promise although ...

1995-01-01

224

Multiphasic helical Computed Tomography of hepatocellular carcinoma. Evaluation after various percutaneous ablation procedures; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo differenti procedure ablative percutanee  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to report the personal experience with helical CT evaluation of hepatocellular carcinoma treated with various percutaneous interventional procedures. From December 1996 to September 1998 it were examined with helical CT 41 patients (73 nodules in all) with hepatocellular carcinoma treated with percutaneous ablation therapies: conventional ethanol injection in 18 subjects (31 nodules), one-shot ethanol injection 3 (8 nodules), radiofrequency thermal ablation in 16 (25 nodules), and combined chemo embolization and ethanol injection in 4 (9 nodules). CT performed was 4-27 days after the last session, acquiring biphasic volumetric images in 14 patients and triphasic volumetric images in 27. A second treatment with subsequent CT study was performed for 28 lesions; 15 underwent 3 serial studies and 6 underwent 4 studies. Compared with pretreatment findings, the diameter was unchanged in 62% of the nodules and increased in ...

1999-12-01

225

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors; Combined with hyperthermia  

Energy Technology Data Exchange (ETDEWEB)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial arrangements of implants, which yield high radiation dose on tumors ...

1990-05-01

226

Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors  

International Nuclear Information System (INIS)

The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise intracranial arrangements of implants, which yield high radiation dose on tumors ...

1990-01-01

227

Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent  

Energy Technology Data Exchange (ETDEWEB)

To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in all cases. Among the five patients who encountered problems, ...

2002-07-01

228

Percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency: efficacy of mechanical thrombectomy with using the stone basket  

Energy Technology Data Exchange (ETDEWEB)

We wanted to evaluate the procedural success after percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency and the efficacy of performing mechanical thrombectomy with using the stone basket. From March 2004 to June 2005, 36 thrombosed native hemodialysis access shunts in the upper limbs (brachiocephalic fistulas: 16 and radiocephalic fistulas: 20) were percutaneously treated in 30 patients. Declotting procedures were performed with using urokinase (100,00-200,000 unit) and manual catheter-directed thrombo-aspiration in all the patients. Angioplasty (6 mm in diameter and 4 cm in length) was performed at the identified area of the stenosis and /or with maceration of the thrombus. In 14 cases with massive thrombosis that was refractory to the above mentioned declotting procedures, mechanical thrombectomy with using a Wittich nitinol stone basket (Cook, Bloomington, IN) was performed. Data regarding the procedural success rate and the ...

2006-06-15

229

Optical diagnostics based on elastic scattering: Recent clinical demonstrations with the Los Alamos Optical Biopsy System  

Energy Technology Data Exchange (ETDEWEB)

A non-invasive diagnostic tool that could identify malignancy in situ and in real time would have a major impact on the detection and treatment of cancer. We have developed and are testing early prototypes of an optical biopsy system (OBS) for detection of cancer and other tissue pathologies. The OBS invokes a unique approach to optical diagnosis of tissue pathologies based on the elastic scattering properties, over a wide range of wavelengths, of the microscopic structure of the tissue. The use of elastic scattering as the key to optical tissue diagnostics in the OBS is based on the fact that many tissue pathologies, including a majority of cancer forms, manifest significant architectural changes at the cellular and sub-cellular level. Since the cellular components that cause elastic scattering have dimensions typically on the order of visible to near-IR wavelengths, the elastic (Mie) scattering properties will be strongly wavelength dependent. Thus, morphology and size changes can be ...

1993-08-01

230

Non-selective cervical and cerebral three-dimensional rotational angiography  

International Nuclear Information System (INIS)

To evaluate the usefulness of three-dimensional (3D) rotational angiography, cervical carotid or cerebral angiography was done without catheterizing the branches of the thoracic aorta. A 5-Fr pig-tail type catheter was passed into the ascending aorta via the radial artery or the femoral artery. Optimal carotid angiogram views were obtained using approximately 45 ml of contrast medium at a flow rate of 15 ml/sec. Optimal cerebral angiogram views were obtained using approximately 70 ml of contrast medium at a flow rate of 20 ml/sec. The contrast medium concentration was 300 to 350 mgI/ml. A satisfactory view could be obtained in 5 of 8 (63%) cases on cervical carotid 3D angiography and in 8 of 14 (57%) cases on cerebral 3D angiography. In all cases, no complications were noted. This method offers the advantages of requiring a relatively short procedure time and a decrease in radiation exposure. Further studies are needed to determine the optimal time to start filming ...

2007-09-01

231

New placement of TIPS during pregnancy for recurring esophageal variceal bleeding: Estimation of fetal radiation exposure; TIPS-Neuanlage in der Schwangerschaft bei rezidivierender Oesophagusvarizenblutung - Abschaetzung der fetalen Strahlenexposition  

Energy Technology Data Exchange (ETDEWEB)

Recurrent variceal bleeding due to liver cirrhosis led to treatment with a transjugular intrahepatic portosystemic shunt (TIPS) in a pregnant woman at 20 weeks` gestation. Fetal radiation exposure was estimated to be less than 10 mSv. The use of a graduated catheter allowed measurement of field size and reliable determination of the patient`s entrance dose. Radiation exposure of an approximated fetal dosage of 5.2 mSv did not justify abortion for medical reasons. Therefore, TIPS procedure is not generally contraindicated during pregnancy itself. TIPS placement may be a therapeutic option related to the severity of the underlying maternal disease, after radiation exposure of the fetus has been estimated. (orig.) [Deutsch] Bei rezidivierender Oesophagusvarizenblutung auf dem Boden einer Leberzirrhose wurde bei bestehender Schwangerschaft der 20. Woche ein transjugulaerer portosystemischer Stent-Shunt (TIPS) neu angelegt. Praeinterventionell wurde die zu erwartende ...

1998-10-01

232

Multidetector-row helical CT: analysis of time management and workflow  

International Nuclear Information System (INIS)

The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min (#+-#2.06 min); (b) 4:36 min (#+-#2.43 min); (c) 4:11 min (#+-#2.55 min); (d) 0:43 min (#+-#0.15 min); (e) 6:59 min (#+-#2.39 min); (f) 09:51 min (#+-#3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, ...

2002-03-01

233

Laparoskopisk kolecystektomi  

DEFF Research Database (Denmark)

Forty-one patients with uncomplicated gall stone disease were laparoscopied with the object of cholecystectomy. The procedure was accomplished in 36 patients, but the operation had to be transformed to a conventional open operation in five: Fibrosis made dissection of the gall bladder hazardous in four and bleeding during the procedure made immediate laparotomy necessary in one patient, whose postoperative course was uneventful. The median operating time was 100 minutes, range was 60-250 minutes. The only operative complication was bleeding from a trocar puncture hole on the first postoperative day which stopped spontaneously in one patient. Eighteen were sent home on the first postoperative day and 12 patients on the second day. Peroperative cholangiography was performed employing the Olsen-Reddick cholangiography forceps. We have designed a special catheter, which greatly facilitates the procedure. The procedure was accomplished in 27 of 32 planned cases. Two ...

1993-01-01

234

Potential of sub-ablative pulsed CO{sub 2} laser irradiation on inhibition of artificial caries-like lesion progress in bovine dental enamel; Potencial de inibicao da progressao da carie artificial por irradiacao sub-ablativa com laser de CO{sub 2} pulsado em esmalte dental bovino  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to investigate whether sub-ablative pulsed C0{sub 2} laser (1 0,6 {mu}m) irradiation is capable of reducing the susceptibility of the dental enamel to demineralization, and thus achieving a potential caries-protective effect. The crowns of 51 bovine front teeth, embedded in acrylic resin and polished until exposure of flat enamel surface, were used. The samples were cut in cubes of 10x10 mm, and totally coated with acid-resistant nail varnish, except for an enamel exposed window of 16 mm square. Three groups (n=17) were obtained: control group (CG) not irradiated; group laser A (LA) and group laser B (LB) where the samples were irradiated. The conditions were 60 mJ, 100 Hz, 0,3 J/cm{sup 2} for LA and 135 mJ, 10 Hz, 0,7 J/cm{sup 2} for LB. Two samples of each group were submitted to SEM analysis and fifteen to demineralization in 3 ml acetate buffer solution (0,1 mol/L) with pH 4,5 for 24h at 37 deg C, with regular agitation. After the ...

2005-07-01

235

Microfabricated polyester conical microwells for cell culture applications.  

Science.gov (United States)

Over the past few years there has been a great deal of interest in reducing experimental systems to a lab-on-a-chip scale. There has been particular interest in conducting high-throughput screening studies using microscale devices, for example in stem cell research. Microwells have emerged as the structure of choice for such tests. Most manufacturing approaches for microwell fabrication are based on photolithography, soft lithography, and etching. However, some of these approaches require extensive equipment, lengthy fabrication process, and modifications to the existing microwell patterns are costly. Here we show a convenient, fast, and low-cost method for fabricating microwells for cell culture applications by laser ablation of a polyester film coated with silicone glue. Microwell diameter was controlled by adjusting the laser power and speed, and the well depth by stacking several layers of film. By using this setup, a device containing hundreds of microwells ...

2011-05-26

236

Influence of the deposition techniques on the quality of the epitaxial buffer layers on textured Ni substrates  

Energy Technology Data Exchange (ETDEWEB)

In order to fabricate high temperature superconducting tapes for power applications, the authors have analyzed different buffer layer architectures grown on textured Ni substrates suitable for YBCO deposition. Due to its optimal lattice matching the studied structures present as top layer a CeO{sub 2} film. The deposition of CeO{sub 2} on Ni substrates was performed by pulsed laser ablation and by e-beam evaporation at different temperatures. The films obtained by the two deposition techniques have not optimal structural properties, having a polycrystalline component. The misorientation of CeO{sub 2} is probably due to the formation of NiO at the interface between the film and the substrate during the deposition process even if no oxygen is introduced. In order to prevent Ni oxidation an intermediate 2000 {angstrom} Pd thick film was deposited by e-beam. Furthermore, the lattice mismatch between Pd and CeO{sub 2} is smaller than that between Ni and CeO{sub 2}. The ...

1999-04-20

237

Glacier changes in the Siberian Altai Mountains, Ob river basin (1952-2006) estimated with high resolution imagery  

Energy Technology Data Exchange (ETDEWEB)

The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km{sup 2}), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km{sup 2}). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer air temperature by 1.03 deg. C ...

2007-10-15

238

Glacier changes in the Siberian Altai Mountains, Ob river basin (1952-2006) estimated with high resolution imagery  

International Nuclear Information System (INIS)

The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km"2), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km"2). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer air temperature by 1.03 deg. C (from 1951 ...

239

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on long-lived radioactive isotopes including ...

240

Energy Conversion and Storage Program: 1992 Annual report  

Energy Technology Data Exchange (ETDEWEB)

This report is the 1992 annual progress report for the Energy Conversion and Storage Program, a part of the Energy and Environment Division of the Lawrence Berkeley Laboratory. Work described falls into three broad areas: electrochemistry; chemical applications; and materials applications. The Energy Conversion and Storage Program applies principles of chemistry and materials science to solve problems in several areas: (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes and chemical species, and (5) study and application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to ...

1993-06-01

241

Energy Conversion and Storage Program. 1990 annual report  

Energy Technology Data Exchange (ETDEWEB)

The Energy Conversion and Storage Program applies chemistry and materials science principles to solve problems in (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes, and (5) application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to develop advanced power systems for electric vehicle and stationary energy storage applications. Topics include identification of new electrochemical couples for advanced rechargeable batteries, improvements in battery and fuel-cell materials, and the establishment of engineering principles applicable to electrochemical energy storage and ...

1992-03-01

242

Energy Conversion and Storage Program  

Energy Technology Data Exchange (ETDEWEB)

The Energy Conversion and Storage Program applies chemistry and materials science principles to solve problems in (1) production of new synthetic fuels, (2) development of high-performance rechargeable batteries and fuel cells, (3) development of advanced thermochemical processes for energy conversion, (4) characterization of complex chemical processes, and (5) application of novel materials for energy conversion and transmission. Projects focus on transport-process principles, chemical kinetics, thermodynamics, separation processes, organic and physical chemistry, novel materials, and advanced methods of analysis. Electrochemistry research aims to develop advanced power systems for electric vehicle and stationary energy storage applications. Topics include identification of new electrochemical couples for advanced rechargeable batteries, improvements in battery and fuel-cell materials, and the establishment of engineering principles applicable to electrochemical energy storage and ...

1992-03-01

243

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated ...

2006-03-15

244

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...

2006-03-01

245

Calibration free laser-induced breakdown spectroscopy of oxide materials  

Energy Technology Data Exchange (ETDEWEB)

The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse duration {approx} 6 ns) ablation was ...

2010-08-15

246

The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers  

International Nuclear Information System (INIS)

Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months ...

2000-12-01

247

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI ...

1998-03-01

248

Investigation of dominant loss mechanisms in low-temperature polymer electrolyte membrane fuel cells  

Energy Technology Data Exchange (ETDEWEB)

This thesis deals with the analysis of dominant loss mechanisms in direct methanol fuel cells (DMFC) and hydrogen fed polymer electrolyte membrane fuel cells (PEFC) by means of experimental characterization and modeling work. Due to different fuels used in these two fuel cell types, the dominant loss mechanisms are different in their nature. All in-situ characterization techniques that are used in this work are based on a novel test fuel cell with embedded reference electrodes. The first part of this work presents a new concept for realizing a reference electrode configuration in a polymer electrolyte membrane fuel cell by means of laser ablation. The laser beam is used to evaporate a small gap into the electrode surface of a catalyst coated membrane (CCM) to isolate the reference electrode from the working/counter electrode (WE/CE). This method enables the simultaneous ablation of the electrodes on both sides of the CCM because the membrane is ...

2010-07-01

249

Heated lipiodol as an embolization agent for transhepatic arterial embolization in VX2 rabbit liver cancer model  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the therapeutic effect of heated (60 deg. C) lipiodol via hepatic artery administration in a rabbit model of VX2 liver cancer. Materials and methods: Thirty male New Zealand white rabbits were randomly divided into three groups with 10 rabbits assigned to each group. VX2 carcinoma cells were surgically implanted into the left hepatic lobe. The tumors were allowed to grow for 2 weeks, and studies were performed until the diameter of the tumors detected by ultrasonograph reached 2-3 cm. Under anesthesia, trans-catheter hepatic arterial embolization was performed and doxorubicin-lipiodol (37 deg. C) (1 mL), lipiodol (60 deg. C) (1 mL) or control (physiological saline (37 deg. C) (1 mL)) solution was injected into the hepatic arteries of animals in the three groups. One week later, the volume of the tumor was measured by ultrasonograph again. The serum of all rabbits was collected before injection and at 4 and 7 days after injection, and the level ...

2010-02-15

250

Local control and functional results after twice-daily radiotherapy for Ewing's sarcoma of the extremities  

International Nuclear Information System (INIS)

Purpose: Radiotherapy (RT) has been the predominant local treatment for Ewing's sarcoma of bone at the University of Florida. Twice-daily hyperfractionated RT was initiated in 1982 to improve local control and functional outcome. This retrospective review compares the results of once-daily vs. twice-daily RT in patients with primary Ewing's sarcoma of an extremity, with emphasis on functional outcome. Methods and Materials: Between June 1971 and January 1990, 37 patients were treated at the University of Florida for nonmetastatic Ewing's sarcoma of bone with a primary lesion in an extremity. Three patients underwent amputation. Of 34 patients treated with RT, 31 had RT alone and 3 had a combination of RT and local excision. Before 1982, 14 patients received once-daily RT; since 1982, 17 patients have received twice-daily RT. Doses of once-daily RT varied from 47 to 61 Gy at 1.8-2 Gy per fraction. Doses of twice-daily RT varied, depending on the response of the soft-tissue component of ...

1996-07-01

251

Traces of evidence. Nuclear forensics and illicit trafficking  

International Nuclear Information System (INIS)

An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other radioactive material of unknown origin are ...

2003-06-01