Energy Technology Data Exchange (ETDEWEB)
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
1981-09-01
Energy Technology Data Exchange (ETDEWEB)
A heat transfer (condenser) of a domestic freezer was tested in a vertical channel in order to study the influence of the chimney effect in the optimization of the heat transfer coefficient. The variation of the opening of the channel, position and the heating power of the heat exchanger in the heat transfer coefficient was considered. The influence of the surface emissivity on the heat transfer by thermal radiation was studied with the heat exchanger testes without paint and with black paint. The air velocity entering the channel was measured with a hot wire anemometer. In order to evaluate the chimney effect, the heat exchanger was testes in a open ambient. This situation simulates its operational conditions when installed on the freezer system. The variables collected in the experimental procedures was gathered in the form of dimensionless parameters as Nusselt, Rayleigh, Grashof ...
1997-07-01
Heat-transfer augmentation in rod bundles near grid spacers
International Nuclear Information System (INIS)
Heat-transfer augmentation by straight grid spacers in rod bundles is studied for single-phase flow and for post-critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single-phase flow is also examined. Governing heat-transfer mechanisms are analyzed, and predictive formulations are established. For single-phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. The effect of local velocity increasing near swirling spacer is considered. For post critical heat flux (CHF) dispersed flow, the heat transfer by thermal radiation, fin cooling, and vapor convection near the spacer are calculated. The predictions are compared with experimental data with satisfactory agreement.
1982-01-01
International Nuclear Information System (INIS)
A numerical and experimental investigation is carried out in a solar thermochemical reactor for the thermal dissociation of ZnO at 2000 K using concentrated solar energy. The reactor consists of a cavity-receiver lined with ZnO particles and directly exposed to high-flux irradiation. A transient heat transfer model is formulated to link the rate of radiation, convection, and conduction heat transfer to the reaction kinetics. The radiosity and Monte Carlo methods are applied to obtain the distribution of net radiative fluxes at the internal surfaces of the reactor cavity and at the surface of the ZnO bed. Validation is accomplished in terms of the calculated and measured transient temperature profiles and chemical reaction rates.
2008-04-01
Radiative properties of a solar cavity receiver/reactor with quartz window
British Library Electronic Table of Contents (United Kingdom)
An energy transfer and conversion model for high-temperature solar cavity receivers has been developed using the transport behaviour of solar radiation as described by the spectral radiative exchange factors. A Monte-Carlo ray-tracing method coupled with optical properties was adopted, to predict radiation characteristics of the solar collector system by calculating radiative exchange factors. A cavity receiver with a plano-convexo quartz window was proposed, based upon the directional characteristics of the focal flux and the redistribution effect of the quartz window. Parametric studies on the windowed receiver provided a more uniform flux distribution, higher efficiency and lower loss than the windowless receivers. The predicted results serve as a design reference for the solar receiver...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...
2005-03-18
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a ...
1992-10-01
Energy Technology Data Exchange (ETDEWEB)
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate ...
1995-02-01
Elemental transfer from Chinese soil via the diet to the whole human body
International Nuclear Information System (INIS)
Based on results from recent studies of elemental dietary intake and organ or tissue content for adult Chinese men, quoted nationwide elemental concentrations in Chinese soil and newly published national average consumption of dietary foods, values of both transfer coefficients and discrimination factor (DF) for transfer from soil via the diet to both critical organs and the whole body have been calculated for important elements in radiation protection, including alkaline earths, alkali metals, rare earths and other related elements. These calculations have used both the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) model and the DF method. In the UNSCEAR model, the basic parameters used to describe the transport of radionuclides are the transfer coefficients P_i_j, which describe the relationship of ...
2008-12-01
A mathematical model for simulating shallow solar ponds for treatment of industrial wastewater
Energy Technology Data Exchange (ETDEWEB)
This paper presents a mathematical model to analyze the solar evaporation in a shallow pond in steady state, when the inlet flow rate, concentration, surface area and solar radiation are given. The simultaneous heat and mass transfer mechanisms are considered for quantifying the amount of evaporated water to the atmosphere and the actual absorbed heat by wastewater is calculated to obtain the bottom temperature of water pond. The heat losses to air by radiation and convection mechanisms are considered and the heat transmission across the water film is evaluated by the forced convection mechanism. 6 refs., 5 figs., 1 tab.
1996-12-31
British Library Electronic Table of Contents (United Kingdom)
An analysis is presented for the effects of chemical reaction and thermal radiation on hydromagnetic free convection heat and mass transfer for a micropolar fluid via a porous medium bounded by a semi-infinite vertical porous plate in the presence of heat generation. The plate moves with a constant velocity in the longitudinal direction and the free stream velocity follows an exponentially small perturbation law. A uniform magnetic field acts perpendicularly to the porous surface in which absorbs the micropolar fluid with a suction velocity varying with time. Analytical expressions are computed numerically. Numerical calculations are carried out the purpose of the discussion of the results which are shown on graphs and the effects of the various dimensionless parameters entering into the p...
2009-01-01
We compare the predictions of four different algorithms for the distribution of ionized gas during the Epoch of Reionization. These algorithms are all used to run a 100 Mpc/h simulation of reionization with the same initial conditions. Two of the algorithms are state-of-the-art ray-tracing radiative transfer codes that use disparate methods to calculate the ionization history. The other two algorithms are fast but more approximate schemes based on iterative application of a smoothing filter to the underlying source and density fields. We compare these algorithms' resulting ionization and 21 cm fields using several different statistical measures. The two radiative transfer schemes are in excellent agreement with each other (with the cross-correlation coefficient of the ionization fields >0.8 for k 0.6 for k < 1 h/Mpc). When used to predict the 21cm power spectrum at different ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
To resolve the central thermal safety issue for spent fuel dry storage concrete canister design or Wolsung (CANDU) nuclear power plant unit 1, a thermal analysis method has been developed for the complicated geometry of rod bundles and the multi-dimensional and multi-mode heat transfer phenomena. The canister geometry is simplified and combined heat transfer by conduction, convection, and radiation is considered through effective heat transfer coefficients. Mean temperature distributions of the fuel bundles within the fuel basket are obtained by solving the heat transfer problem using an existing computer code HEATING5. The measured steady state temperature distribution within a mock-up of a storage basket is compared to the calculated result. Steady state and/or transient fuel temperature distributions have been calculated for various ...
1992-07-01
International Nuclear Information System (INIS)
To resolve the central thermal safety issue for spent fuel dry storage concrete canister design or Wolsung (CANDU) nuclear power plant unit 1, a thermal analysis method has been developed for the complicated geometry of rod bundles and the multi-dimensional and multi-mode heat transfer phenomena. The canister geometry is simplified and combined heat transfer by conduction, convection, and radiation is considered through effective heat transfer coefficients. Mean temperature distributions of the fuel bundles within the fuel basket are obtained by solving the heat transfer problem using an existing computer code HEATING5. The measured steady state temperature distribution within a mock-up of a storage basket is compared to the calculated result. Steady state and/or transient fuel temperature distributions have been calculated for various ...
1992-10-31
PROCEEDINGS OF THE 1966 HEAT TRANSFER AND FLUID ...
... mass of gray gas by thermal radiation; An experimental study of the turbulent wake behind a cone at M = 5; Heat transfer augmentation by steady ...
Emittance theory for thin film selective emitter
Energy Technology Data Exchange (ETDEWEB)
Thin films of high temperature garnet materials such as yttrium aluminum garnet (YAG) doped with rare earths are currently being investigated as selective emitters. This paper presents a radiative transfer analysis of the thin film emitter. From this analysis the emitter efficiency and power density are calculated. Results based on measured extinction coefficients for erbium-YAG and holmium-YAG are presented. These results indicated that emitter efficiencies of 50 percent and power densities of several watts/sq cm are attainable at moderate temperatures (less than 1750 K).
1994-08-01
Photoluminescence enhancement of Sm{sup 3+} ions in the vicinity of noble-metal nanoparticles
Energy Technology Data Exchange (ETDEWEB)
The photoluminescence intensity of an optical emitter changes when placed in close proximity to a noble-metal nanoparticle, due to two contributions. First, the optical near-field of the nanoparticle leads to a change in excitation rate of the emitter. Secondly, the emission efficiency is changed due to an optical energy transfer from the emitter to the metal nanoparticle, which provides additional radiative and non-radiative decay channels. In this work we investigate the photoluminescence of Sm{sup 3+} ions, which are embedded in SiO{sub 2}. The photoluminescence spectrum of ions in proximity to single silver and gold nanoparticles is measured. The influence of the spectral position of the nanoparticle plasmon peak on the photoluminescence yield will be discussed and compared with model calculations.
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF
1999-05-01
Energy Technology Data Exchange (ETDEWEB)
E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood ...
1999-12-05
Induced radiation during scattering of channeled electrons and positrons by point defects
Energy Technology Data Exchange (ETDEWEB)
In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.
1984-12-01
MINEQL-PC. Chemical Equilibrium Composition of Aqueous Systems
Energy Technology Data Exchange (ETDEWEB)
MINEQL is a subroutine package to calculate equilibrium composition of an aqueous system, accounting for mass transfer.
1986-11-21
Energy Technology Data Exchange (ETDEWEB)
The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to ...
2009-12-01
International Nuclear Information System (INIS)
We investigate some aspects of the radiation damage mechanisms in biomolecules, focusing on the modelling of resonant fragmentation caused by the attachment of low-energy electrons (LEEs) initially ejected by biological tissues when exposed to ionizing radiation. Scattering equations are formulated within a symmetry-adapted, single-center expansion of both continuum and bound electrons, and the interaction forces are obtained from a combination of ab initio calculations and a nonempirical model of exchange and correlation effects developed in our group. We present total elastic scattering cross-sections and resonance features obtained for the equilibrium geometries of glycine, alanine, proline and valine. Our results at those geometries of the target molecules are briefly shown to qualitatively explain some of the fragmentation patterns obtained in experiments. We further carry out a one-dimensional (1D) modeling for the ...
2010-10-01
Study of the thermal plasma etching at atmospheric pressure on silica rods
International Nuclear Information System (INIS)
Etching of SiO_2 rods has been obtained with a dc torch with argon as the process gas in an air environment at atmospheric pressure; the high temperature of the plasma jet causes vaporization of the exposed area. The apparatus and torch operative parameters have been set up to obtain a depth etch rate of up to 0.6 mm min"-"1 corresponding to 0.826 g min"-"1. An enthalpy probe has been employed to monitor the plasma conditions before the thermal plasma etching process and from the experimental etch rate a surface rod temperature of T_s_u_r = 2057 K has been derived. Etching has been obtained with uniformity over the entire exposed area with peak to peak differences below 1%. The plasma to rod heat transfer has been simulated using a commercial CFD code Fluent (copyright). The model consists of a non-steady two-dimensional simulation for a compressible turbulent fluid, with an adapted grid calculation. Boundary conditions have been set out using ...
2004-04-21
Energy Technology Data Exchange (ETDEWEB)
The paper presents cloud structure models for Jupiter's Great Red Spot, Equatorial and North Tropical Zones, North and South Temperate Zones, and North and South Polar Regions. The models are based on images of Jupiter in three methane bands and nearby continuum radiative transfer calculations include multiple scattering and absorption from three aerosol layers. The model results include the transition in the upper-cloud altitude to 3 km lower altitude from the tropical zones to temperate zones and polar regions, a N/S asymmetry in cloud thickness in the tropical and temperature zones, and the presence of aerosols up to about 0.3 bar in the Great Red Spot and Equatorial Zone. It is concluded that polarization data are sensitive to aerosols in and above the upper cloud layer but insensitive to deeper cloud structure.
1980-02-01
Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.
Energy Technology Data Exchange (ETDEWEB)
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
1998-09-11
Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces
Energy Technology Data Exchange (ETDEWEB)
A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative error of ...
1981-10-01
Energy Technology Data Exchange (ETDEWEB)
Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.
1999-07-01
Heat transfer. Fundamentals. 5. rev. ed.
International Nuclear Information System (INIS)
This textbook contains the following main topics: Heat conductivity, convection, condensation and evaporation, radiation heat transfer and heat exchangers. It includes the physical foundations for all these aspects and many examples. (orig.)
Sophisticated applications of radiation heat transfer
International Nuclear Information System (INIS)
A large amount of energy has been consumed so far in so called matured industries such as iron and steel, oil refinery, petrochemical, ceramic, paper and pulp manufacturing and so forth. A successive stimulation on the preceding industries has to be enhanced from a technological viewpoint in order to maintain a further development based on novel and innovative technologies. In this regard, energy technology has become and will be increasingly important in a high temperature system so that the basic concept for heat transfer augmentation methods by thermal radiation is reviewed briefly in accord with the recent developments together with theoretical background and the prominent features. The heat transfer augmentation related to thermal radiation is summarized.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
The Monte Carlo simulation method is applied to calculate the nucleon transfer part of the imaginary optical-model potential in colliding heavy ions. In the process of transfer of nucleons from one nucleus to the other, forward and backward neutrons and protons are treated separately by taking into consideration the effect of the Coulomb forces and the potential energy surfaces (driving forces). The Pauli exclusion principle is also incorporated properly in the calculation.
1988-08-08
Medium voltage analytical electron microscopy microanalysis versus radiation damage
Energy Technology Data Exchange (ETDEWEB)
The kinetic energy transferred to some elements by an electron of kinetic energy 100 to 400 kV is discussed. The displacement rates are compared to the signal generation. (DCL)
1985-09-01
Radiative transfer in a solar absorbing particle laden flow
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, ...
1985-11-01
We review results from general relativistic axisymmetric magnetohydrodynamic simulations of accretion in Sgr A*. We use general relativistic radiative transfer methods and to produce a broad band (from millimeter to gamma-rays) spectrum. Using a ray tracing scheme we also model images of Sgr A* and compare the size of image to the VLBI observations at 230 GHz. We perform a parameter survey and study radiative properties of the flow models for various black hole spins, ion to electron temperature ratios, and inclinations. We scale our models to reconstruct the flux and the spectral slope around 230 GHz. The combination of Monte Carlo spectral energy distribution calculations and 230 GHz image modeling constrains the parameter space of the numerical models. Our models suggest rather high black hole spin ($a_*\\approx 0.9$), electron temperatures close to the ion temperature ($T_i/T_e \\sim 3$) and high ...
2010-01-01
UK PubMed Central (United Kingdom)
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
Total hemispherical emittance was measured for the SP-100 reactor fuel cladding alloy (Nb-l% Zr). Based on a standard test method (ASTM C 835-82), experiments were conducted on a reference sample of oxidized stainless steel and then on a sample of actual cladding. The sample is heated in a vacuum by passing DC current through it until reaching equilibrium. Measurements are made of the electrical power dissipated in the sample and of the surface temperature. Using the Stefan-Boltzmann Law and some key assumptions concerning conductive and radiative heat transfer, the measured quantities are used to calculate emittance. Calculated values for unoxidized cladding range from 0.159 +/- 5.35% at 913 K to 0.200 +/- 4.51% at 1091 K. Highest value measured after onset of visible oxidation was 0.339 +/- 3.92% at 1269 K.... SP-100, Reactor, Emittance, Niobium, Fuel cladding, Emissivity.
1992-12-01
Simulations and Analytic Calculations of Bubble Growth During Hydrogen Reionization
We present results from a large volume simulation of Hydrogen reionization. We combine 3d radiative transfer calculations and an N-body simulation, describing structure formation in the IGM, to detail the growth of HII regions around high redshift galaxies. Our simulation tracks 1024^3 dark matter particles, in a box of side length 65.6 Mpc/h. This large volume allows us to accurately characterize the size distribution of HII regions throughout most of the reionization process. At the same time, our simulation resolves many of the small galaxies likely responsible for reionization. It confirms a picture anticipated by analytic models: HII regions grow collectively around highly-clustered sources, and have a well-defined characteristic size, evolving from a sub-Mpc scale at the beginning of reionization to R>10 Mpc towards the end. We present a detailed statistical description of our results, and compare them with a ...
2006-01-01
Modelling of MeV alpha particle energy transfer to lower hybrid waves
Energy Technology Data Exchange (ETDEWEB)
The interaction between a lower hybrid wave and a fusion alpha particle displaces the alpha particle simultaneously in space and energy. This results in coupled diffusion. Diffusion of alphas down the density gradient could lead to their transferring energy to the wave. This could, in turn, put energy into current drive. Here we calculate numerical solutions for the alpha energy transfer and study a range of conditions that are favourable for wave amplification from alpha energy. We find that it is possible for fusion alpha particles to transfer a large fraction of their energy to the lower hybrid wave. The numerical calculation shows that the net energy transfer is not sensitive to the value of the diffusion coefficient over a wide range of practical values. An extension of this idea, the use of a lossy boundary to enhance the energy ...
1994-05-01
Modelling of MeV alpha particle energy transfer to lower hybrid waves
International Nuclear Information System (INIS)
The interaction between a lower hybrid wave and a fusion alpha particle displaces the alpha particle simultaneously in space and energy. This results in coupled diffusion. Diffusion of alphas down the density gradient could lead to their transferring energy to the wave. This could, in turn, put energy into current drive. Here we calculate numerical solutions for the alpha energy transfer and study a range of conditions that are favourable for wave amplification from alpha energy. We find that it is possible for fusion alpha particles to transfer a large fraction of their energy to the lower hybrid wave. The numerical calculation shows that the net energy transfer is not sensitive to the value of the diffusion coefficient over a wide range of practical values. An extension of this idea, the use of a lossy boundary to enhance the energy ...
Modeling of MeV alpha particle energy transfer to lower hybrid waves
Energy Technology Data Exchange (ETDEWEB)
The interaction between a lower hybrid wave and a fusion alpha particle displaces the alpha particle simultaneously in space and energy. This results in coupled diffusion. Diffusion of alphas down the density gradient could lead to their transferring energy to the wave. This could, in turn, put energy into current drive. An initial analytic study was done by Fisch and Rax. Here the authors calculate numerical solutions for the alpha energy transfer and study a range of conditions that are favorable for wave amplification from alpha energy. They find that it is possible for fusion alpha particles to transfer a large fraction of their energy to the lower hybrid wave. The numerical calculation shows that the net energy transfer is not sensitive to the value of the diffusion coefficient over a wide range of practical values. An extension of this idea, the use of a ...
1993-10-01
International Nuclear Information System (INIS)
... 5. Formation of the annular two-phase flow regime, with a wavy film on the
1974-01-01
High temperature heat transfer augmentation
International Nuclear Information System (INIS)
The heat transfer augmentation is reviewed in view of high temperature heat exchangers illuminating the contribution of radiative heat transfer. A number of means and/or devices are presented as well as the sophisticated concept which will be promoted to the extended applications in matured industries such as iron and steel, oir refinery, petro-chemical. It should be emphasized that the more creative and innovatory technology has to be promoted in order to stimulate and refresh the foregoing industries, recognizing the increasing importance of the energy resources.
1985-08-01
Pairing effects in nucleon transfer reactions in the system sup 144 Sm+ sup 88 Sr at 4. 7 MeV/u
Energy Technology Data Exchange (ETDEWEB)
Proton and neutron transfer populating low-lying states have been studied in the system {sup 144}Sm+{sup 88}Sr at an energy below the Coulomb barrier. The experimental cross sections for the single proton transfer are well reproduced by DWBA-calculations using spectroscopic information from light ion reactions. The two-proton transfer appears enhanced relative to the uncorrelated sequential transfer of single protons. The same holds for the transfer of proton pairs, the enhancement is kept for the second pair. This is interpreted as a supercurrent between two superfluid nuclear proton-pair wave functions: More mass and charge is transported per time unit in pairs than by single nucleons. Neutron transfer is observed with large cross sections and is found to contribute to the energy loss observed in the transfer ...
1990-05-01
Pairing effects in nucleon transfer reactions in the system "1"4"4Sm+"8"8Sr at 4.7 MeV/u
International Nuclear Information System (INIS)
Proton and neutron transfer populating low-lying states have been studied in the system "1"4"4Sm+"8"8Sr at an energy below the Coulomb barrier. The experimental cross sections for the single proton transfer are well reproduced by DWBA-calculations using spectroscopic information from light ion reactions. The two-proton transfer appears enhanced relative to the uncorrelated sequential transfer of single protons. The same holds for the transfer of proton pairs, the enhancement is kept for the second pair. This is interpreted as a supercurrent between two superfluid nuclear proton-pair wave functions: More mass and charge is transported per time unit in pairs than by single nucleons. Neutron transfer is observed with large cross sections and is found to contribute to the energy loss observed in the transfer reactions. For ...
COOLOD, Steady-State Thermal Hydraulics of Research Reactors
International Nuclear Information System (INIS)
1 - Description of program or function: The COOLOD-N2 code provides a capability for the analyses of the steady-state thermal-hydraulics of research reactors. This code is a revised version of the COOLOD-N code, and is applicable not only for research reactors in which plate-type fuel is adopted, but also for research reactors in which rod-type fuel is adopted. In the code, subroutines to calculate temperature distribution in rod-type fuel have been newly added to the COOLOD-N code. The COOLOD-N2 code can calculate fuel temperatures under both forced convection cooling mode and natural convection cooling mode. A 'Heat Transfer package' is used for calculating heat transfer coefficient, DNB heat flux etc. The 'Heat Transfer package' is a subroutine program and is especially developed for research reactors in which plate-type fuel is adopted. In case of rod-type ...
Potential Hazards from Neutrino Radiation at Muon Colliders
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
1999-01-01
Estimation of X-rays dose in the crystals of final thickness
International Nuclear Information System (INIS)
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Numerical analysis of methane-air combustion considering radiation effect
Energy Technology Data Exchange (ETDEWEB)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation ...
2008-12-15
Numerical analysis of methane-air combustion considering radiation effect
International Nuclear Information System (INIS)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect ...
2008-12-01
Radiation-stimulated diffusion of aerosols
Energy Technology Data Exchange (ETDEWEB)
The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.
1984-04-01
Radiation-induced chemical modification of wood
International Nuclear Information System (INIS)
The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.
1985-01-01
Enhanced heat transfer through oscillatory flow
Energy Technology Data Exchange (ETDEWEB)
The enhancement of longitudinal heat transfer by means of fluid pulsation in a pipe has been investigated analytically and numerically, including the transient state. The effects of pulsation amplitude, frequency, and pipe length on thermal properties such as effective thermal diffusivity and delay time are clarified. Their effects on numerical calculations are also presented and suggestions for efficient numerical calculations of this problem are made concerning the combination of parameters.
1994-03-01
Apoptosis induced by high- and low-LET radiations
International Nuclear Information System (INIS)
Cell death after irradiation occurs by apoptosis in certain cell populations in tissues. The phenomenon also occurs after high linear energy transfer (LET) irradiation, and the relative biological effectiveness (RBE) is 3 to 4 (with respect to low-LET radiation and apoptosis in intestinal crypts) for neutrons with energies of 14 MeV and up to 600 MeV. It is thought that p53 plays a role in the phenomenon, as radiation-induced apoptosis is not observed in p53-null animals. (orig.).
Energy transfer study of europium-tetracycline complexes
Energy Technology Data Exchange (ETDEWEB)
The aim of this work was to study the energy transfer mechanisms from the ligand to the central lanthanide ion of tetracycline-europium (Tc-Eu) complex. The absorption spectra of a EuCl{sub 3}.H{sub 2}O solution was measured and absorption cross-section of Eu{sup 3+} was estimated. The observed overlap predicts a resonant energy transfer from Tetracycline to Eu{sup 3+}. The microscopic parameter of energy transfer was obtained using the overlap integral calculation considering a dipole-dipole energy transfer mechanism and results were compared considering an energy transfer by exchange. In this work, we report also the optical properties of Tc-Eu complex when urea hydrogen peroxide is added to the aqueous solution.
2007-01-15
The impact of accretion disk winds on the X-ray spectrum of AGN: Part 1 - XSCORT
(abridged) The accretion disk in AGN is expected to produce strong outflows, in particular a UV-line driven wind. Despite providing a good fit to the data, current spectral models of the X-ray spectrum of AGN observed through an accretion disk wind are ad-hoc in their treatment of the properties of the wind material. In order to address these limitations we adopt a numerical computation method that links a series of radiative transfer calculations, incorporating the effect of a global velocity field in a self-consistent manner (XSCORT). We present a series of example spectra from the XSCORT code that allow us to examine the shape of AGN X-ray spectra seen through a wind, for a range of velocity and density distributions, total column densities and initial ionization parameters. These detailed spectral models clearly show considerable complexity and structure that is strongly affected by all these factors. The presence of ...
2007-01-01
In response to the consultation from the National Council on Radiation Protection and Measurements (NCRP) to the International Commission on Radiological Protection (ICRP) committee 2, retention and excretion of 239Pu deposited at wound site were calculated by coupling together the proposed NCRP wound model and the current ICRP systemic model of Pu. The physicochemical forms considered were the soluble form categorized into 'Strong Retention', and the colloidal, particulate and fragmentary forms. The results are summarized as follows. If in soluble form, immediate medical intervention is needed to prevent uptake of radionuclides to body tissues, and prompt wound monitoring is essential for an accurate estimation of the initially deposited radioactivity. If in particulate form, a multi-component exponential equation leads to an overestimation of the absorption rate to blood because of significant lymph node drainage. The committed doses in the ...
2007-06-07
British Library Electronic Table of Contents (United Kingdom)
We used a radiation-transfer equation estimate of July surface temperatures (Ts) in China's Yongding River basin based on thermal infrared Landsat TM images from 1987 and 2005 and Landsat ETM+ images from 2000. Based upon the Ts-NDVI relationship space, we analyzed the scatterplot of Ts versus NDVI to calculate a temperature-vegetation dryness index (TVDI). We used a linear regression model between soil moisture and TVDI to estimate soil moisture to depths of 10 and 20cm. We produced a land use and cover type map by classification of the Landsat images, and used the map to study the influence of land use and cover type changes on soil moisture. Some areas of farmland in 1987 had been converted into grassland by 2000, and soil moisture mainly increased, with increases ranging from 20 to 60%...
2010-01-01
Materials considerations for the National Spallation Neutron Source target
Energy Technology Data Exchange (ETDEWEB)
The National Spallation Neutron Source (NSNS), in which neutrons are generated by bombarding a liquid mercury target with 1 GeV protons, will place extraordinary demands on materials performance. The target structural material will operate in an aggressive environment, subject to intense fluxes of high energy protons, neutrons, and other particles, while exposed to liquid mercury and to water. Components that require special consideration include the Hg liquid target container and protective shroud, beam windows, support structures, moderator containers, and beam tubes. In response to these demands a materials R and D program has been developed for the NSNS that includes: selection of materials; calculations of radiation damage; irradiations, post irradiation testing, and characterization; compatibility testing and characterization; design and implementation of a plan for monitoring of materials performance in service; and materials engineering ...
1997-08-01
Detonating Failed Deflagration Model of Thermonuclear Supernovae II. Comparison to Observations
We develop and demonstrate the methodology of testing multi-dimensional supernova models against observations by studying the properties of one example of the detonation from failed deflagration (DFD) explosion model of thermonuclear supernovae. Using time-dependent multi-dimensional radiative transfer calculations, we generate the synthetic broadband optical light curves, near-infrared light curves, color evolution curves, full spectral time-series, and spectropolarization of the model, as seen from various viewing angles. All model observables are critically evaluated against examples of well-observed, standard Type Ia supernovae (SNe Ia). We explore the consequences of the intrinsic model asphericity by studying the dependence of the model emission on viewing angle, and by quantifying the resulting dispersion in (and internal correlations between) various model observables. These statistical properties of the model are ...
2006-01-01
A deterministic partial differential equation model for dose calculation in electron radiotherapy
International Nuclear Information System (INIS)
High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss ...
2010-07-07
Smith-Purcell radiation in the highly relativistic regime
International Nuclear Information System (INIS)
An electron moving over the surface of a diffraction grating will transfer a part of its kinetic energy to radiation via a velocity synchronous coupling with a slow space harmonic component of the field. Since the phase velocity of a slow space harmonic is less than the speed of light, the slow components decay exponentially, or evanesce, with distance above the grating and the evanescence scale is determined by the product of the relative velocity, #beta#, the relative energy, #gamma#, and the wavelength #lambda#. Thus, in the relativistic regime, good electron - grating coupling can be maintained at beam heights that are greater than the emitted wavelength. In order to explore this regime a series of experiments have been carried out with moderately energetic beams and an experiment with the 70-MeV beam at the Accelerator Test Facility is in the planning stage. The work has two basic goals: the first is to explore the characteristics of the ...
1995-08-21
Cooperative spontaneous emission from two different atoms
International Nuclear Information System (INIS)
The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
The theoretical analysis of a partially-ionized hydrogen gas flow (gas temperatures of approximately 10,000 to 20,000 K) through a particular class of magnetohydrodynamic (MHD) generators and the preliminary design of these MHD generators as open cycle, electric power supplies are performed. Analysis of the gas flow through these ultra-high temperature MHD generators requires a coupled gas dynamics/radiative heat transfer solution. Gas dynamics are modeled by a set of quasi-one-dimensional, nonlinear differential equations which account for friction, convective and radiative heat transfer and the interaction between the ionized gas and applied magnetic field. Radiative heat transfer is modeled using non-gray, absorbing-emitting two- and three-dimensional P-1 approximations which permit an arbitrary variation of the spectral absorption coefficient with frequency. ...
1990-01-01
Spontaneous radiation of an electron beam in a free-electron laser with a quadrupole wiggler
Energy Technology Data Exchange (ETDEWEB)
A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.
1986-09-01
Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)
International Nuclear Information System (INIS)
Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds ...
1978-01-01
Long-lived quantum coherence in photosynthetic complexes at physiological temperature
UK PubMed Central (United Kingdom)
Photosynthetic antenna complexes capture and concentrate solar radiation by transferring the excitation to the reaction center that stores energy from the photon in chemical bonds. This process occurs...Full Text Available
2010-07-20
Cooperative Effects on Transient Spectral Hole Burning
... of Dist SpeA tI/ __LLL5' Page 5. 3 the coherent effects on the spontaneous radiation, we calculate the pump- field-induced ...
1992-06-01
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
1980-01-01
British Library Electronic Table of Contents (United Kingdom)
The behavior of proton transfer facilitated by a novel thiazole derivative, N-methyl-4-(4-phenoxyphenyl)thiazol-2-amine (MPPT), across the water/1,2-dichloroethane (1,2-DCE) interface was investigated electrochemically. The ionic partition diagram for MPPT was obtained from interpretation of the cyclic voltammograms. The apparent partition coefficient of MPPT was evaluated by the shaking-flask method under experimental conditions, while that for the protonated form of MPPT was calculated from its transfer potential obtained from the ionic partition diagram. It was suggested that the mechanism for transfer of MPPT across the water/1,2-DCE) interface depends on the pH of the aqueous phase. The parameters of the facilitated proton transfer across the water/1,2-DCE interface were evaluated as ...
2011-01-01
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed ...
2006-07-15
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
1984-11-08
Energy Technology Data Exchange (ETDEWEB)
The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been carried out in ...
2008-07-01
Cask consolidated spent fuel thermal analyses using the COBRA-SFS code
Energy Technology Data Exchange (ETDEWEB)
The COBRA-SFS computer code was used to perform thermal-hydraulic analyses of consolidated spent fuel stored in casks. The ability of the COBRA-SFS code to model consolidated fuel was evaluated by comparing predictions with experimental data obtained from electrically heated rod bundles by Ridihalgh, Eggers, and Associates and Eggers Ridihalgh Partners, Inc. under sponsorship of the Electric Power Research Institute. The calculations agreed with the measured temperatures well within the bounds of experimental error. Based on the evaluation results, best-estimate temperature predictions were performed for consolidated fuel in several cask designs. Results are presented for the REA 2023 BWR cask, the CASTOR-1C BWR cask, and the Concrete Sealed Storage Cask designed for Monitored Retrievable Storage (MRS). The cask simulation results indicate that consolidation of spent fuel results in a reduction of convection and radiation heat ...
1986-04-01
Somatic radiation risk in X-ray diagnostics
Energy Technology Data Exchange (ETDEWEB)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
1983-12-01
Somatic radiation risk in X-ray diagnostics
International Nuclear Information System (INIS)
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
1983-01-01
British Library Electronic Table of Contents (United Kingdom)
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
2007-01-01
Scientific Electronic Library Online (English)
Abstract in english Numerical solutions for the effects of radiation on a MHD convective heat transfer past a semi-infinite porous plate with a magnetic field are obtained. It is assumed that the porous plate moves with a constant velocity in the direction of fluid flow, and the free stream velocity follows the exponentially increasing small perturbation law. The magnetic field acts perpendicular to the porous surface which absorbs the fluid with a suction velocity varying with time. The gov (more) erning equations for the flow are transformed into a system of nonlinear ordinary differential equations by perturbation technique and then are solved numerically by using the shooting method. The effects of the various parameters on the velocity, temperature profiles as well as the surface skin-friction and surface heat transfer are illustrated graphically.
2008-12-01
International Nuclear Information System (INIS)
By the department Radio-ecology of the Laboratory for Radiation Research, in the period 1981 up to 1989 inclusive, the transfer has been studied, from soil to plant, of a number of important activation and fission products, originating in the nuclear-power production in nuclear power plants. The purpose of this study was twofold: on the one side the quantification of this transfer for various agrarian systems and on the other side to find out in how far, after an accidental contamination, certain agriculture activities can influence essentially the transfer and subsequently the radiation burden for the population. Emphasis lay, the last years, in particular upon this second aspect. The results of this study form essential basic data for diffusion models for radioactive materials which, in turn, are important in estimating the effects of measures. (author). 6 refs.; 4 figs.
Fourier analysis of energy transfer data obtained by simulating a 14-MeV #alpha#-particle in water
International Nuclear Information System (INIS)
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
2010-01-15
Optimum profiles for asymmetrical longitudinal fins in annular ducts
Energy Technology Data Exchange (ETDEWEB)
In the present work the geometry of annular ducts with asymmetrical longitudinal fins is optimized in order to enhance the heat transfer under laminar coolant flow conditions. The heat transferred is also maximized for a given amount of material or hydraulic resistance. Polynomial profiles are assigned to the two lateral fin surfaces. Velocity and temperature distributions on the annular duct cross section are determined with the help of a finite-element model. A global heat transfer coefficient and an equivalent Nusselt number are then calculated. Lastly, optimum asymmetrical fins obtained by means of a genetic algorithm are shown for different situations and their performance is compared with those of optimum symmetrical fins.
2000-04-01
Collisional excitation transfer between lithium isotopes
Energy Technology Data Exchange (ETDEWEB)
Excitation transfer between the 3S[sub 1/2] states of the lithium isotopes [sup 6]Li and [sup 7]Li is measured in a thermionic diode. The 3S level is excited by off-resonant two-photon transitions with a single mode cw laser. The relative densities of the directly excited and collisionally populated levels are probed by further laser excitation to the 12P levels. An energy transfer cross section of 585 A[sup 2] [+-] 160 A[sup 2] is found at the experimental temperature of about 850 K. A simple semiclassical calculation yields a cross section of 450 A[sup 2]. (orig.)
1995-01-01
Unsteady state heat transfer in the vertical walls of a building
Energy Technology Data Exchange (ETDEWEB)
The unsteady state heat transfer behaviour of a vertical wall subject to the effects of uniform radiation is investigated and the dimensional analysis of combined heat transfers by conduction, convection and radiation is presented. The convective heat transfer coefficients used in the numerical model are determined experimentally by means of an assembly resembling the conditions encountered in the dwelling (variable temperatures and heat flows in time and space, wall associated with a floor, radiative flux outside the wall). In routine conditions (homogeneous wall dimensions, temperature differentials less than 40/sup 0/C), it is shown that the problem depends in practice on three parameters (instead of five) and that nomographs can give the energy accumulated in the wall as a function of its geometric and thermal charactersitics and the external conditions ...
1982-12-01
Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus
International Nuclear Information System (INIS)
Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.
1987-08-01
Performance of large LWR system codes in calculating the steam-generator heat-transfer behavior
Energy Technology Data Exchange (ETDEWEB)
This paper presents a series of modeling experiences and problems in simulating the thermal-hydraulic behavior of large PWR steam generators using the RELAP4 and RELAP5 computer codes. Sensitivity studies investigating the heat transfer characteristics of both once-through and U-tube steam generators are discussed. Suggestions and recommendations are given for effective use and potential future improvements of these codes.
1982-01-01
International Nuclear Information System (INIS)
The results of calculated and experimental investigation of interphase isotopic exchange efficiency in countercurrent columns are given when separation processes of isotope mixtures are taken place with use of liquid-solid systems. Effect of liquid phase flow on transfer unit height in ion exchange separation of boron, lithium, nitrogen isotopes is considered. 40 refs.; 5 figs.
Double proton migrations in dimeric methaboric, formic, cis-nitrous and nitric acids
International Nuclear Information System (INIS)
Using ab initio (SCF/6-31G) method, mechanisms of proton migrations in methaboric acid dimers have studied. It is shown that in all the dimers considered a cooperative transfer of protons occurs. The calculated values of activation barriers of cooperative proton transfer reactions in the dimers are equal to 28.6 kcal/mol.
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been ...
1996-12-31
Calculation method for microwave pyramidal horn radiators with curvilinear generatrix
British Library Electronic Table of Contents (United Kingdom)
Calculation method for pyramidal horn radiators (PHR) with curvilinear generatrix has been developed on the basis of the theory of waveguide tapers. This method makes it possible to reduce the value of spurious reflection coefficients and transformation of the principal wave into waves of higher order modes by forming generatrixes of walls with specific curvilinearity.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.
1982-10-01
International Nuclear Information System (INIS)
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).
1982-01-01
Pressure drop and heat transfer in gas-cooled rod bundles
International Nuclear Information System (INIS)
Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework could support a Radiative Equilibrium ...
2010-01-01
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss ...
2008-01-01
Hydrogen isotope effects in hydride transfer reactions of formaldehyde and glyoxal
International Nuclear Information System (INIS)
In the presence of hydroxyl anion, both formaldehyde and glyoxal are known to undergo rearrangements involving intermolecular and intramolecular hydride transfer (the Cannizzaro and Benzilic acid rearrangements respectively). The authors report ab initio SCF-MO calculations of the transition state geometries, the activation barriers, and the hydrogen isotope effects for these two reactions. The structure of the transition state for the rection involving formaldehyde is usually basis set dependent, becoming more linear and symmetrical as the basis set size increases. In contrast, the analogous transition state for the glyoxal reaction involves a highly non-linear hydride transfer. They find the isotope effects to be quite low for the Cannizzaro reaction, and significantly larger for the non-linear benzilic acid rection, in apparent contradiction to Westheimer's suggestion the isotope effects reach a maximum for linear ...
1987-04-01
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide ...
2003-01-01
Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL
Recently the author showed that the widely used simulation code TDA3D, even though a single frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, the author applies this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, he shows that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is substracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.
1998-08-01
Power spectrum calculation for the Cornell Wiggler A SASE experiment at BNL
Energy Technology Data Exchange (ETDEWEB)
Recently, we showed (Yu, Phys. Rev. E 58 (1998) 4991) that the widely used simulation code TDA3D, even though a single-frequency code, can be used to determine the power spectrum in the SASE process with excellent approximation in the exponential growth regime. In this paper, we apply this method to the BNL Cornell Wiggler A SASE experiment as an example. When the gain is not very high, there are many modes in the radiation, which seems to make the analytical calculation very difficult. However, we show that the increment of the radiation due to SASE over the spontaneous radiation can be expanded in terms of guided modes with rapid convergence. Thus when the spontaneous radiation is subtracted from the SASE power during the calculation, there is a good agreement between the analytical theory and the numerical simulation.
1999-06-01
Heavy fuel oil combustion in a cylindrical laboratory furnace: measurements and modeling
Energy Technology Data Exchange (ETDEWEB)
The finite-volume based commercial CFD-code Fluent was used to simulate the reacting flow in a heavy fuel oil fired laboratory furnace. Both the standard {kappa}-{epsilon} turbulence model and the Reynolds stress model (RSM) were tested. The combustion model was based on the conserved scalar (mixture fraction) and prescribed probability density function approach. The heavy fuel oil droplet trajectories were predicted by solving the momentum equations for the droplets using the Lagrangian treatment. The soot distribution in the furnace was calculated by solving a transport equation for the soot mass fraction. Simple expressions for the soot formation and oxidation rates were employed. The radiation heat transfer equation was solved using the finite volume method. The formation of thermal NO from molecular nitrogen was modeled according to the extended Zeldovich mechanism. Fuel-based NO was modeled assuming that all the ...
2005-03-01
X-ray generation by the Smith-Purcell effect
International Nuclear Information System (INIS)
Smith-Purcell (S-P) radiation is produced when electrons graze the surface of a grating. Calculations based on the theory of diffraction radiation show that, given severe restrictions on e"--beam quality, S-P radiation is highly efficient. Efficient S-P x-ray generation requires relativistic e"- beams having a transverse momentum and dimension whose product approaches the Heisenberg uncertainty limit.
Solar flux distribution in cavity receivers with parabolic dish collector
Energy Technology Data Exchange (ETDEWEB)
Thermal absorption with its combined thermal and mechanical loads in a solar receiver does depend significantly on the distribution of incident solar radiation. For a cavity receiver with paraboloid collectar a method is derived which enables the calculation of solar radiation distribution on the areas inside the receiver. The theoretical bases are presented first, and a subsequent example shows the influence of the most important geometric parameters on the distribution of solar radiation.
1982-01-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents fundamental researches based on the electronic structure calculations and X absorption spectroscopy, allowing the knowledge on nuclear fuels at an atomic scale. They bring a better understanding of these material behavior to accurate the macroscopic simulation. The calculation methods, the experimental techniques of validation and the ab initio calculations results are detailed. (A.L.B.)
2000-07-01
Envelope correlation in (N, N) MIMO antenna array from scattering parameters
DEFF Research Database (Denmark)
A simple closed-form equation to calculate the envelope correlation between any two receiver or transmitter antennas in a multi-input multi-output (MIMO) system of an arbitrary number of elements is derived. The equation uses the scattering parameters obtained at the antenna feed point to calculate the envelope correlation coefficient. This approach has the advantage that it does not require knowledge of the antenna radiation pattern. Numerical data that include conductor and permittivity loss are shown to validate the approach. Using the scattering parameters for calculating the envelope correlation is less laborious and relatively cheaper, as compared to the radiation pattern approach.
2006-01-01
Gravitational waves from the big bang
Energy Technology Data Exchange (ETDEWEB)
The gravitational radiation produced by the big bang is calculated in order to provide a condition for the unification of the gravitational and electromagnetic forces. By analogy with electromagnetic radiation and under the assumption that gravity is also quantized, it is shown that matter would have decoupled from gravitational radiation at a time of approximately 10 to the -43rd sec and would have dominated it at 10 to the -17th sec. Furthermore, the theory predicts a background gravitational radiation temperature of 0.003 K which peaks at a wavelength of about 1 m, which may be detected by the comparison of the synchronization of clocks at increasing distances.
1980-12-20
Cut diagrams for high energy scatterings
International Nuclear Information System (INIS)
A new approach is introduced to study QCD amplitudes at high energy and comparatively small momentum transfer. Novel cut diagrams, representing the resummation of Feynman diagrams, are used to simplify the calculation and to avoid delicate cancellations encountered in the usual approach. An explicit calculation to the sixth order is carried out to demonstrate the advantage of cut diagrams over Feynman diagrams. copyright 1996 The American Physical Society.
Synchrotron radiation from electron beams in plasma-focusing channels.
Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron ...
2002-05-20
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal ...
1986-01-01
High-efficiency pump for space helium transfer. Final Technical Report
Energy Technology Data Exchange (ETDEWEB)
A centrifugal pump was developed for the efficient and reliable transfer of liquid helium in space. The pump can be used to refill cryostats on orbiting satellites which use liquid helium for refrigeration at extremely low temperatures. The pump meets the head and flow requirements of on-orbit helium transfer: a flow rate of 800 L/hr at a head of 128 J/kg. The overall pump efficiency at the design point is 0.45. The design head and flow requirements are met with zero net positive suction head, which is the condition in an orbiting helium supply Dewar. The mass transfer efficiency calculated for a space transfer operation is 0.99. Steel ball bearings are used with gas fiber-reinforced teflon retainers to provide solid lubrication. These bearings have demonstrated the longest life in liquid helium endurance tests under simulated pumping conditions. Technology developed in the project ...
1991-12-01
Ganglioside GM_1 spontaneous transfer between phospholipid vesicles
International Nuclear Information System (INIS)
The transfer kinetics of the monosiaylated glycosphingolipid, GM_1, between different size phospholipid vesicles was measured using molecular sieve chromatography. At desired time intervals, small unilamellar donor vesicles were separated from large unilamellar acceptor vesicles by elution from a Sephacryl S-500 column ["3H]-GM_1 net transfer was calculated relative to ["1"4C]-cholesteryl oleate, which served as a nontransferable marker in the donor vesicles. The initial GM_1 transfer rate between 1-palmitoyl-2-oleoyl phosphatidylcholine vesicles at 45"0C deviated slightly from first order kinetics and possessed a half time of 3.6 days. This transfer half time is an order of magnitude shorter than that observed from the desiaylated derivative of GM_1. The transfer kinetics are consistent with the authors recent electron microscopic results suggesting a molecular ...
1986-06-08
Core Heat Transfer Model Validation of the TASS/SMR-S Code using the Bennett's Test
International Nuclear Information System (INIS)
The SMART (System-integrated Modular Advanced ReacTor) which is a 330 MWt advanced integral PWR was developed by the KAERI (Korea Atomic Energy Institute) for electricity generation and seawater desalination. A thermal hydraulic evaluation and analysis of the SMART is performed by the TASS /SMR-S (Transient And Setpoint Simulation/System integrated Modular Reactor-Safety). The TASS/SMR-S code has various models reflecting the design features of the SMART such as the drift flux model, the core models (core power and core heat transfer model), the component models, and the specific models. One of the core models is the core heat transfer model. The role of this model is to calculate the heat flux and radial temperature profiles at a fuel rod surface using the relevant heat transfer correlations for all of the heat transfer modes. Also it is modeled to meet the requirements of the 10 ...
2010-10-01
International Nuclear Information System (INIS)
The LWR fuel performance analysis computer code, FRAPCON-1, are evaluated to investigate the performance of CANDU fuel elements loaded in Wolsung-1 reactor. The FRAPCON-1 models of neutron flux depression in fuel and of fuel-to-cladding heat transfer are modified, and the validity of fission gas release model for CANDU fuel is evaluated. And the heavy water properties are provided in calculating the heat transfer coefficient between cladding and coolant. By using the modified code, FRAPCON-1-CSK, the sensitivity studies are carried out for Wolsung-1 fuel element design parameters. The performance analysis is also performed for Wolsung-1 fuel elements. The calculated results are discussed in terms of LWR fuel design criteria because of unavailability of CANDU fuel design criteria. (Author).
1983-01-01
Microclimatic conditions at the external surface of building envelopes
Energy Technology Data Exchange (ETDEWEB)
The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat ...
1998-12-31
The dust distribution in edge-on galaxies. Radiative transfer fits of V and K'-band images
Aims: I have analyzed a sample of seven nearby edge-on galaxies observed in the V and K'-band, in order to infer the properties of the dust distribution. Methods: A radiative transfer model, including scattering, have been used to decompose each image into a stellar disk, a bulge, and a dust disk. The parameters describing the distributions have been obtained through standard X^2 minimization techniques. Results: The dust disks fitted to the V-band images are consistent with previous work in literature: the radial scalelength of dust is larger than that for stars (h_d/h_s ~ 1.5); the dust disk has a smaller vertical scalelength than the stellar (z_d/z_s ~ 1/3); the dust disk is almost transparent when seen face-on (central, face-on, optical depth tau_0 =0.5-1.5). Faster radiative transfer models which neglect scattering can produce equivalent fits, with changes in the derived parameters within the ...
2007-01-01
International Nuclear Information System (INIS)
The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change ...
2006-06-19
International Nuclear Information System (INIS)
Studies were conducted on mating behaviour and reproductive performance of a) Earias vittella (F.) males rendered sterile by exposing them to 300 Gy gamma rays and b) F_1 sterile males obtained by exposing parent male to 100 Gy gamma rays. For the study, males were allowed only one mating with a normal female. Results revealed that premating period, period in copula and per cent insects mating were not adversely affected in case of both types of sterile males and fecundity also remained unaffected. However, in both types of sterile males, incidence of spermatophore transfer without sperm was very large and such an occurrence (including reduced spermatophore transfer) was significantly higher in case of radiation sterilized males compared to the F_1 sterile males. Inability to produce and transfer spermatophore and/or sperm appeared to be a major cause behind the reduced mating competitiveness of both ...
Improvement of the efficiency of a bare solar collector by means of turbulence promoters
Energy Technology Data Exchange (ETDEWEB)
A steady-state mathematical model was developed for a bare collector. Results obtained by previous authors for heat transfer and friction in rectangular ducts with periodic disturbances were employed to evaluate the effect of such disturbances on bare collector efficiency and on its pressure drop. An effective efficiency, which takes into account extra heat obtained and additional mechanical (electric) energy consumption for moving air when heat-transfer augmentation devices are employed, was defined. Simulation results are given for a bare collector, with and without perturbations, showing efficiency and effective efficiency dependence on collector dimensions, solar radiation intensity, disturbance diameter and pitch for collector performance optimization. (author).
1990-01-01
British Library Electronic Table of Contents (United Kingdom)
An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...
2009-01-01
Heat transfer augmentation by gas-particle two-phase flow
International Nuclear Information System (INIS)
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat ...
1995-06-01
Mathematical child phantom for the calculation of dose to the organs at risk
Energy Technology Data Exchange (ETDEWEB)
In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.
1988-05-01
Calculations of the self-amplified spontaneous emission performance of a free-electron laser.
Energy Technology Data Exchange (ETDEWEB)
The linear integral equation based computer code (RON: Roger Oleg Nikolai), which was recently developed at Argonne National Laboratory, was used to calculate the self-amplified spontaneous emission (SASE) performance of the free-electron laser (FEL) being built at Argonne. Signal growth calculations under different conditions are used for estimating tolerances of actual design parameters. The radiation characteristics are discussed, and calculations using an ideal undulator magnetic field and a real measured magnetic field will be compared and discussed.
1999-04-20
Ultrafast resonance energy transfer in bio-molecular systems
British Library Electronic Table of Contents (United Kingdom)
In this article, we present our consistent efforts to explore the dynamical pathways of the migration of electronic radiation by using ultrafast (picosecond/femtosecond time scales) F?rster resonance energy transfer (FRET) technique. The ultrafast non-radiative energy migration from an intrinsic donor fluorophore (Tryptophan, Trp214) present in domain IIA of a transporter protein human serum albumin (HSA) to various non-covalently/covalently attached organic/inorganic chromophores including photoporphyrin IX (PPIX), polyoxovanadate [V15As6O42(H2O)]-6 clusters (denoted as V15) and CdS quantum dots (QDs) has been explored. We have also used other covalently/non-covalently attached extrinsic fluorogenic donors (NPA, ANS) in order to exploit the dynamics of resonance energy migration of an enz...
2010-01-01
Transfer Factors of {sup 85}Sr and {sup 137}Cs for Rice in Three Paddy Soils from the Wolsung Area
Energy Technology Data Exchange (ETDEWEB)
Several nuclear power plants are operating in Wolsung area, a south-east coastland of Korea. In addition, a medium-level radioactive waste repository is under construction there. If radionuclides are released from these facilities, food crops could be radioactively contaminated, leading to human exposure to internal radiations via food consumption. There are a number of rice fields around the Wolsung nuclear sites. However, almost nothing has yet been reported on the transfer of radionuclides to rice plants from Wolsung soils. In this study, {sup 85}Sr and {sup 137}Cs transfer factors (TFs) were measured for the rice in three paddy soils collected around the Wolsung nuclear sites.
2009-10-15
Transfer Factors of 85Sr and 137Cs for Rice in Three Paddy Soils from the Wolsung Area
International Nuclear Information System (INIS)
Several nuclear power plants are operating in Wolsung area, a south-east coastland of Korea. In addition, a medium-level radioactive waste repository is under construction there. If radionuclides are released from these facilities, food crops could be radioactively contaminated, leading to human exposure to internal radiations via food consumption. There are a number of rice fields around the Wolsung nuclear sites. However, almost nothing has yet been reported on the transfer of radionuclides to rice plants from Wolsung soils. In this study, 85Sr and 137Cs transfer factors (TFs) were measured for the rice in three paddy soils collected around the Wolsung nuclear sites
2009-10-01
Thermal modeling of solar central receiver cavities
Energy Technology Data Exchange (ETDEWEB)
Results are presented from a numerical model of the steady-state energy transfer in molten-salt-in-tube solar cavity receivers that includes convective energy transfer at a local (spatially resolved) level. Molten salt energy absorption and gray radiative transfer between all cavity surfaces are also included. This model is applied to the Molten Salt Subsystem Component Test Experiment (MSS/CTE) cavity receiver. Results for this receiver indicate the global (entire cavity) receiver thermal efficiency is invariant within a few percent to most parameters investigated, although front surface temperatures of the nonabsorbing walls vary considerably, and are particularly sensitive to the type of convective submodel used. Absorption efficiencies indicate the effects of the cavity enclosure environment. For all conditions investigated, tube inner wall temperatures remain under 855 K, ensuring that the salt ...
1989-05-01
Transient behaviour of solar heated radiation receivers for small gas turbine power plants
Energy Technology Data Exchange (ETDEWEB)
Solar heating of gas turbine plants steps back more and more into the focus of current research. The mainly instationary operation of solar turbine power plants can only be predicted with sufficient accuracy if the transient behaviour of the receiver for the solar radiation is known. Therefore the transient behaviour of cavity receivers of different design is investigated. The mathematical model used for the simulation of the heat transfer and energy storage processes is illustrated. Computed results for receivers with various inner lining are compared and evaluated concerning their use in practice.
1987-03-01
Transient behavior of solar heated radiation receivers for small gas turbine power plants
Energy Technology Data Exchange (ETDEWEB)
Solar heating of gas turbine plants is moving back to the focus of current research. The mainly unsteady operation of solar turbine power plants can only be predicted with sufficient accuracy if the transient behavior of the solar radiation receiver is known. Therefore the transient behavior of cavity receivers of different designs is investigated. The mathematical model used to simulate heat transfer and energy storage is illustrated. Computed results for two receivers with different inner lining are compared and evaluated concerning their use in practice.
1987-01-01
Effects of thermophoresis and radiation on laminar flow along a semi-infinite vertical plate
British Library Electronic Table of Contents (United Kingdom)
The present contribution deals with the thermophoresis particle deposition and thermal radiation effects on the flow, heat and mass transfer characteristics in a viscous fluid over a semi-infinite vertical porous plate. The governing boundary layer equations are written into a dimensionless form by similarity transformations. The transformed coupled nonlinear ordinary differential equations are solved numerically by means of the fourth-order Runge?Kutta method with a shooting technique. The effects of different parameters on the dimensionless velocity, temperature, and concentration profiles are shown graphically. In addition, results for the local skin-friction coefficient, the local Nusselt number, and the local Sherwood number are tabulated and discussed.
2011-01-01
Effects of thermophoresis and radiation on laminar flow along a semi-infinite vertical plate
The present contribution deals with the thermophoresis particle deposition and thermal radiation effects on the flow, heat and mass transfer characteristics in a viscous fluid over a semi-infinite vertical porous plate. The governing boundary layer equations are written into a dimensionless form by similarity transformations. The transformed coupled nonlinear ordinary differential equations are solved numerically by means of the fourth-order Runge-Kutta method with a shooting technique. The effects of different parameters on the dimensionless velocity, temperature, and concentration profiles are shown graphically. In addition, results for the local skin-friction coefficient, the local Nusselt number, and the local Sherwood number are tabulated and discussed.
2011-04-01
UK PubMed Central (United Kingdom)
14C has long been used as a tracer for quantifying the in...Full Text Available
2010-04-28
Energy Technology Data Exchange (ETDEWEB)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater ...
2010-11-15
International Nuclear Information System (INIS)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater ...
2010-11-01
Natural-convection cooling of heat-producing radioactive waste in transport and storage casks
International Nuclear Information System (INIS)
The heat transfer characteristics of a newly developed transport and storage cask for vitrified heat-producing radioactive waste from reprocessing are described. The theoretical layout of the cask was tested by measurements on a prototype cask of the scale 1:1. These measurements confirmed the theoretical thermodynamic layout data. They can be described by the function Nu=CxRa"m, with the constant C, but not the constant m, differing for a vertical and a horizontal position of the cask. The measured velocity and temperature profiles of the cask were verified with an existing code for the calculation of heat transfer from finned horizontal cylinders by natural convection. (orig.).
Energy Technology Data Exchange (ETDEWEB)
Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.
1983-11-01
International Nuclear Information System (INIS)
Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.
1983-01-01
Fluorescence resonance energy transfer using lanthanide-ion doped oxide nanoparticles as donors
We have demonstrated fluorescence resonance energy transfer (FRET) between lanthanide-ion doped oxide nanoparticles acting as donors and organic acceptor molecules (Cy5). Due to the long nanoparticle lifetime and the large Stokes shift between nanoparticle absorption and emission, unambiguous and precise FRET measurements can be performed despite the presence of large free acceptor oncentrations. We determined FRET efficiencies as a function of Cy5 concentration which are in very good agreement with a multiple acceptor-multiple donor calculation.
2006-03-01
International Nuclear Information System (INIS)
A theoretical analysis is presented for the method of determining the concentration distribution of admixtures in zone melting and in the study of diffusion in melts. Continuous mode X-ray fluorescence analysis is considered. The convolution integral interpreting the analog output of the ratemeter was solved applying the mathematical apparatus of Z transformation. The feasibility of the method is tested on an example of the determination of tin distribution in tungsten. With respect to the statistical error (#delta#<1.5%), the maximum integration constant (100 s) and a very slow sample feed (0.025 mm/s) were used. The calculated transfer function reflects the total transfer function of the ratemeter and the recorder used. (M.D.).
1985-01-01
International Nuclear Information System (INIS)
When analyzing the loss-of-coolant accidents at VVER reactor NPP the problem of the effect of noncondensable gases on heat transfer in a horizontal steam generator (HSG) is gaining in importance. Based on the RELAP5/MOD3.2 computer code one analyzed the experiments to condense steam-and-gas mixture in a HSG. The calculations are shown to predict satisfactorily duration of steam generator poisoning from noncondensable gas
2005-03-01
A new empirical potential function and its application to hydrogen bonding
International Nuclear Information System (INIS)
A new potential function based on spectroscopic results for diatomic molecules is presented and applied to the hydrogen bonding systems. The potential energy of interaction is supposed to have electrostatic, polarization, dispersion, repulsion and effective charge-transfer contributions. Estimates of the effective charge-transfer quantity have been made based on the average charge of the proton donor and the acceptor atoms. For dimers such as water, methanol, acetic acid and formic acid, the vibrational stretching frequencies and dimerization energies are calculated and discussed in connection with Badger-Bauer rule. (author).
1981-01-01
Resonance scattering of Lyman-. cap alpha. radiation by hydrogen in the ground state
Energy Technology Data Exchange (ETDEWEB)
We calculate the cross section for the resonance scattering of Lyman-..cap alpha.. radiation by spinless nonrelativistic hydrogen atoms in the ground state using a two-level model. A generalization of Dirac's resonance scattering theory is used together with the exact matrix elements for the electromagnetic interaction. In contrast to the usual treatments in which only the dipole approximation for the matrix elements are taken, the shift in position of the resonance is finite and has a value of 75% of the Lamb shift of the n=1 state. Whether this latter fact is significant in renormalization calculations is left open.
1980-11-01
Analysis of in-pile heat transfer tests: Final report
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of analysis of selected data from the NRU test series dealing with heatup and reflood heat transfer during postulated PWR LOCA conditions. These tests used nuclear fuel rods and some considered clad ballooning and rupture. Also included was an electrically-heated rod ballooning test, REBEKA-6. The COBRA-TF computer program, renamed PYTHONS, was modified and used for the analytical tool. Modifications included provisions for fuel rod gas flow and pressure, creep deformation and rupture, channel blockage, and blockage heat transfer. Calculated clad temperatures for NRU unpressurized rods show quite good agreement with experimental data. The calculated amount and axial extent of clad ballooning for pressurized rods agrees reasonably well with post-test examinations of the NRU bundles. Time to failure was underpredicted in the MT-3 test as a result of the high strength of ...
1986-11-01
Energy Technology Data Exchange (ETDEWEB)
The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and ...
1987-06-15
Spontaneous transfer of ganglioside GM_1 between phospholipid vesicles
International Nuclear Information System (INIS)
The transfer kinetics of the negatively charged glycosphingolipid II"3-N-acetylneuraminosyl-gangliotetraosylceramide (GM_1) were investigated by monitoring tritiated GM_1 movement between donor and acceptor vesicles. After appropriate incubation times at 45 "0C, donor and acceptor vesicles were separated by molecular sieve chromatography. Donors were small unilamellar vesicles produced by sonication, whereas acceptors were large unilamellar vesicles produced by either fusion or ethanol injection. Initial GM_1 transfer to acceptors followed first-order kinetics with a half-time of about 40 h assuming that GM_1 is present in equal mole fractions in the exterior and interior surfaces of the donor vesicle bilayer and that no glycolipid flip-flop occurs. GM_1 net transfer was calculated relative to that of ["1"4C]cholesteryl oleate, which served as a nontransferable marker in the donor vesicles. Factors ...
Investigation of Heat Transfer in Supercritical Fluids for Application to the Generation IV
Energy Technology Data Exchange (ETDEWEB)
Using a facility named SPHINX, which can accommodate a heat transfer test with CO{sub 2} at supercritical pressure, a series of tests was performed. The test geometries include tubes with the inner diameter of 4.4, 6.32 and 9 mm. a concentric annular passages with 8 x 10 mm, and an eccentric annular passages with 9.5 x 12.5 mm. Based on the test results, heat transfer correlations were developed and compared with the existing correlations. The heat transfer deterioration which may occur at certain conditions of heat and mass flux, were carefully studied and the published criteria were reviewed against our test results. Numerical calculation by using commercial CFD code, Fluent, were performed in order to provide the pre-test information for the heat transfer tests. Various turbulence models were evaluated and reliable models were suggested for each case
2007-08-15
Heat transfer augmentation in a rectangular channel with a vee-shaped vortex generator
International Nuclear Information System (INIS)
The unsteady flow and heat transfer are simulated using LES and DNS for a channel with two angled ribs as a vee-shaped vortex generator to augment heat transfer. The vortex generators are attached on the bottom wall of the channel and their angles in respect to the main flow are between 10"o and 30"o. The Prandtl number is 0.71 and the Reynolds numbers based on the inflow velocity and the height of channel are from 200 to 2000. Based on the results of this work, the variations of the Nusselt number, pressure coefficient, bulk temperature, friction factor and Colburn factor with the Reynolds numbers and the incidence angles are provided. The relation between the key parameters of the velocity (friction factor f) and thermal (Colburn factor J) boundary layers is calculated for all cases and their values are compared with the predicted values by the Chilton-Colburn analogy. A comparison between the DNS and LES results is ...
2007-04-01
Turbulent flow in a channel with transverse rib heat transfer augmentation
Turbulent flow in a 2D channel with repeated rectangular rib roughness was numerically simulated using a low Reynolds number form of the k-epsilon turbulence model. Friction factors and average Stanton numbers were calculated for various pitch to rib height ratios and bulk Reynolds numbers. Comparisons with experiment were generally adequate, with the predictions of friction superior to those for heat transfer. The effect of variable properties for channel flow was investigated, and the results showed a greater effect for friction than for heat transfer. Comparison with experiment yielded no clear conclusions. The turbulence model was also validated for a related problem, that of flow downstream of an abrupt pipe expansion.
1993-04-01
Some sensitivities during a LWR severe core-damage sequence
International Nuclear Information System (INIS)
Stable boiloff of core water during a severe LWR accident, that is, boiloff driven only by the decay power generated below the water level, is tractable analytically and is relatively insensitive to axial power distribution. As might be expected, calculated accident event times are sensitive to the fidelity of the decay power model. During later stages of boiloff, heat transfer or transport of energy from above the water level to the residual water can result in an unstable condition during which the boiloff rate increases greatly. The unstable boiloff phenomenon illustrates the highly nonlinear influence of core heat transfer during meltdown and emphasizes the great accuracy requirements which attend the modeling of the accident during periods of enhanced heat transfer when significant zirconium oxidation is possible.
1981-12-04
Improvement of the PGV-1000 steam generator in-vessel components
International Nuclear Information System (INIS)
Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.
1988-01-01
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
Spontaneous radiation decay of weakly bound system in externa field
International Nuclear Information System (INIS)
A new channel of nonlinear ionization of quantum system in a strong laser field is discussed. The probability of spontaneous radiation decay from the ground state in a short-range potential to the final Volkov wave function, is calculated by the first order of the perturbation theory. It is shown that this process at high intensities of the laser field will be comparable with the high harmonic generation. (orig.)
2001-02-01
Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy
International Nuclear Information System (INIS)
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
Population exposure to external natural radiation background in the United States
Energy Technology Data Exchange (ETDEWEB)
This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.
1981-04-01
International Nuclear Information System (INIS)
From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurement results are compared with theoretical calculations.
1984-05-25
Energy Technology Data Exchange (ETDEWEB)
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
2000-07-01
Albedo method applied to coupled neutron-gamma shielding radiations
International Nuclear Information System (INIS)
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
2000-10-15
Review of passive heat transfer augmentation techniques
Energy Technology Data Exchange (ETDEWEB)
Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive ...
2004-12-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and GD-DTPA produced two ...
2003-07-01
The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)
International Nuclear Information System (INIS)
As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.
The effect of temperature on the radiative performance of Ho-YAG thin film selective emitters
Energy Technology Data Exchange (ETDEWEB)
The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.
1995-01-01
Radiation doses from flying through nuclear-debris clouds. Final report, 2-10 January 1985
Energy Technology Data Exchange (ETDEWEB)
Taboada et al. have recently developed a computer model to predict gamma radiation doses to aircrews flying through nuclear-debris clouds. Although the model has the advantages of taking a large number of parameters into account and using the benchmark DELFIC code to model cloud dynamics, it takes up to 20 min for a single run on a mainframe computer. Results from a number of runs have been generalized into empirical formulae. From these results it is possible to estimate worst case gamma radiation doses for complex scenarios using a hand calculator.
1986-04-01
Conformal radiation therapy: technical requirements and clinical applications
International Nuclear Information System (INIS)
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
1995-01-01
International Nuclear Information System (INIS)
For more than thirty years, the IAEA has published a set of documents aimed at the limitation of the radiation exposure of the population from various nuclear activities. In particular, in 1994 the IAEA published Technical Reports Series No. 364, Handbook of Parameter Values for the Prediction of Radionuclide Transfer in Temperate Environments. Over the years, it has proved to be a valuable reference for radioecologists, modellers and authorities in Member States, and has been quoted in numerous impact assessments. Technical Reports Series No. 364 was based on a review of available data up to the end of 1992. However, a number of high quality critical reviews have been produced in recent years for some of the transfer parameter values which merit consideration. Thus, it was assumed that there is sufficient new information available to warrant reconsideration of a significant proportion of the values given in Technical ...
1993-04-05
Energy Technology Data Exchange (ETDEWEB)
The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of ...
2007-07-25
Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...
1990-01-01
We developed a model for radar scattering from the lunar reoglith layer using vector radiative transfer theory. From this model, both the radar backscattering coefficient and the circular polarization ratio can be predicted analytically as a function of regolith parameters.
2010-03-01
International Nuclear Information System (INIS)
Non-design-basis transition changes in the level fluctuations in the surrounds of a hot steam generator collector for a WWER-440 reactor and the corresponding responses of the temperature fields, strains and stresses are examined. A new approach to the thermal calculation of the horizontal steam generator, which is rapid and affords accurate results, is suggested. An important result of the calculation is the shape of the transition region level and the corresponding distribution of the heat transfer coefficient values. This was used for the calculation of the temperature fields, strain and stress of the hot collector. The stress values obtained were deeply below the yield point of the hot collector material but they get superimposed on the stress from overpressure in the primary and secondary circuits. The obtained fluctuations of the secondary medium level in the surrounds of the hot collector give ...
1989-01-01
Thermal and radiation losses in a linear device
Energy Technology Data Exchange (ETDEWEB)
An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ...
1980-11-01
Numerical error analysis of direct integration method
Energy Technology Data Exchange (ETDEWEB)
Numerical errors of PALLAS calculation due to spatial mesh sizes are examined for a typical deep penetration shielding problem of isotropic incident fission neutrons penetrating a 200-cm-thick water slab. The exponential approximation for the source spatial distribution to solve the transport equation based on the direct integration method is verified to be effective for radiation transport in attenuating medium, while the linear approximation employed in the old PALLAS code is found to produce large errors for calculations with large mesh sizes.
1986-01-01
M 1 decay rates of heavy quarkonia with a nonsingular potential
Energy Technology Data Exchange (ETDEWEB)
We use a nonsingular-potential model for heavy quarkonia proposed by Gupta, Repko, and Suchyta to calculate the transition amplitudes for the magnetic-dipole ({ital M}1) one-photon radiative decays of the {ital c{bar c}} and {ital b{bar b}} bound systems. The wave functions of the bound systems are calculated by a nonperturbative treatment. The results are in better agreement with the experimental data than those predicted using other potential models.
1991-09-01
Calculation of atomic spontaneous emission rate in 1D finite photonic crystal with defects
We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.
2009-01-01
Thermal and heat transfer characteristics in a latent heat storage system using lauric acid
Energy Technology Data Exchange (ETDEWEB)
The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the heat ...
2002-12-01
International Nuclear Information System (INIS)
Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in ...
2002-10-20
Comparisons of two-phase microgravity calculations using current and new flow regime maps in RELAP5
Energy Technology Data Exchange (ETDEWEB)
Recently, many experiments designed to quantify the parameters involved in microgravity two-phase flow have been performed. These experiments give significant insight to the differences between the flow regimes in 1-g and microgravity. However, the new correlations for pressure drop, heat transfer, and the flow regime maps are yet to be implemented into analytical methods. The purpose of this study is to model a KC-135 microgravity experiment, using the thermal-hydraulic does RELAP5/MOD2 and ATHENA. A comparison of these experimental results to code calculations from RELAP5/MOD2 and ATHENA is shown. Results show little difference between the ATHENA and the RELAP5 calculations. Also, modifications are made to the two-phase flow regime map in RELAP5 to model microgravity predictions. There is a substantial difference between the code's calculation before and after the changes were implemented. ...
1988-01-01
Comparisons of two-phase microgravity calculations using current and new flow regime maps in RELAP5
International Nuclear Information System (INIS)
Recently, many experiments designed to quantify the parameters involved in microgravity two-phase flow have been performed. These experiments give significant insight to the differences between the flow regimes in 1-g and microgravity. However, the new correlations for pressure drop, heat transfer, and the flow regime maps are yet to be implemented into analytical methods. The purpose of this study is to model a KC-135 microgravity experiment, using the thermal-hydraulic does RELAP5/MOD2 and ATHENA. A comparison of these experimental results to code calculations from RELAP5/MOD2 and ATHENA is shown. Results show little difference between the ATHENA and the RELAP5 calculations. Also, modifications are made to the two-phase flow regime map in RELAP5 to model microgravity predictions. There is a substantial difference between the code's calculation before and after the changes were implemented. The heat ...
1988-11-04
Energy Technology Data Exchange (ETDEWEB)
A numerical model was developed to simulate the combined effects of heat transfer, magnetite oxidation, and NO{sub x} formation in a grate-kiln furnace for taconite pellet induration. Heat transfer from the flame in the kiln was described by the net radiation method. The shrinking core model was used to account for magnetite oxidation on the grate. A novel approach to oxidation of tumbling pellets in a kiln was derived. The Zeldovich mechanism was used to predict thermal NO generation. Temperature fluctuations in the gas streams were estimated with a clipped Gaussian probability density function. The thermal energy balances and mass balances resulted in coupled systems of first-order differential equations, which were solved numerically. The model is capable of predicting NO production and magnetite oxidation in agreement with observation of plant performance. Although the design of the grate-kiln system is for efficient ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are ...
1990-10-01
Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the ...
2005-01-01
Energy Technology Data Exchange (ETDEWEB)
Thermoluminescence (TL) properties of sphene and epidote are of interest in studies related to their radiation damage. Natural and artificially induced TL of these minerals has, therefore, been investigated. Both minerals exhibit complex glow curves with several overlapping peaks. The Tsub(m) -Tsub(STOP) thermal cleaning procedure has revealed three peaks in the ..gamma.. ray induced glow curve of each mineral. That these peaks obey second order kinetics was indicated by the continuously slanting structure of the Tsub(m)-Tsub(STOP) curve. The TL parameters E and s have been calculated using (i) the initial rise method, and (ii) the glow-peak shape method. In general, the values of E calculated by the first method are found to be higher than those from the second. The TL curve-fitting method is also applied in order to calculate these parameters and to serve as a cross-check on the results.
1986-01-01
Status Report of Simulated Space Radiation Environment Facility
Energy Technology Data Exchange (ETDEWEB)
The technology for performance testing and improvement of materials which are durable at space environment is a military related technology and veiled and securely regulated in advanced countries such as US and Russia. This core technology cannot be easily transferred to other country too. Therefore, this technology is the most fundamental and necessary research area for the successful establishment of space environment system. Since the task for evaluating the effects of space materials and components by space radiation plays important role in satellite lifetime extension and running failure percentage decrease, it is necessary to establish simulated space radiation facility and systematic testing procedure. This report has dealt with the status of the technology to enable the simulation of space environment effects, including the effect of space radiation on space materials. This information such as ...
2007-11-15
Measuring characteristics on emissivity using infrared thermometer for RCCS
International Nuclear Information System (INIS)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured emissivity relatively. It ...
2004-12-01
Rigid muffin-tin approximation for the electron-phonon interaction in transition metals
Energy Technology Data Exchange (ETDEWEB)
Progress in calculating the electron-phonon parameters of transition metals has been based on either the rigid muffin-tin approximation (RMTA) or the fitted modified tight-binding approximation (FMTBA). The RMTA has been shown to be remarkably accurate for average electron-phonon properties, but there are indications that RMTA matrix elements may be too small at low momentum transfer. An attempt is made to demonstrate these assertions concerning the accuracy of RMTA and the numerous electron-phonon calculations are placed in a broader perspective by a demonstration of how they can be used to explain the trends in the strength of the electron-phonon coupling among the transition metals and the A-15 compounds. (GHT)
1980-01-01
Information detective quantum efficiency of X-ray film-intensifier foil systems
Energy Technology Data Exchange (ETDEWEB)
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed.
1988-04-01
Information detective quantum efficiency of X-ray film-intensifier foil systems
International Nuclear Information System (INIS)
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed. (orig.).
Convection in the cavity between two rollers: The effect of thermal boundary conditions
Energy Technology Data Exchange (ETDEWEB)
In this study the authors examine the convective cooling provided by fluid trapped in the cavity between two consecutive rollers in a roller bearing. In order to calculate the steady-state temperature of the roller, the designer must know nor only the rolling-contact heat input received by the roller but also the convection cooling effect of the surrounding fluid. Until recently, this lateral convection cooling effect was modeled by assuming a certain (constant) heat transfer coefficient h at the roller surface, and then calculating the steady-state temperature distribution around the roller.
1991-02-01
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation ...
Human exposure to volatile organic compounds in household tap water: the indoor inhalation pathway
International Nuclear Information System (INIS)
This paper addresses the quantification of human exposure to volatile organic compounds (VOC's) as a result of mass transfer from tap water to indoor air. A three-compartment model is developed and used to simulate the 24-h concentration profile within the shower, bathroom, and remaining household volumes of a dwelling. Mass transfers from water to air are derived from measured data for radon and adjusted to account for the difference in mass-transfer properties for VOC's. A preliminary data base for household parameters is used to calculate a range of concentrations and human exposures in U.S. dwellings. The model is used to estimate exposure factors for seven compounds-chloroform, ethylene dibromide, dibromo-chloropropane, methylchloroform, perchloroethylene, trichloroethylene, and carbon tetrachloride. The calculated ratio of indoor-air exposure to tap water concentration is ...
The form factors of the nucleon at small momentum transfer
Energy Technology Data Exchange (ETDEWEB)
We study the low energy expansion of the nucleon`s electroweak form factors in the framework of an effective chiral Lagrangian including pions, nucleons and the {Delta}(1232). We work to third order in the so-called small scale expansion and compare the results with the ones previously obtained in the chiral expansion. In addition, these calculations serve as a first exploratory study of renormalization and decoupling within the small scale expansion. (orig.) 35 refs.
1998-05-25
Steam generator PGV-1000 thermal-hydraulics
International Nuclear Information System (INIS)
The main features are presented of a computer programme for 3-D thermohydraulic and thermodynamic analysis of the PGV-1000 horizontal steam generator used at the Temelin NPP. The programme provides analyses of primary side hydraulics, heat exchange behavior and the steam generator secondary side thermohydraulics and thermodynamics. Given are calculated data on the circulation flow rate, void fraction, heat transfer dynamics and the swelled level. (Z.S.) 9 figs.
1995-09-21
Dynamic behavior of a solar-heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly nonstationary operation of a solar-heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1987-01-01
Dynamic behavior of a solar heated receiver of a gas turbine plant
Energy Technology Data Exchange (ETDEWEB)
The mainly instationary operation of a solar heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
1986-01-01
International Nuclear Information System (INIS)
Radiation chimeras in the early phase after bone marrow transplantation are a good model to study the efficiency of the body's nonspecific defense system represented by macrophages (M phi), polymorphonuclear cells (PMN), and NK cells. These cell types are present in large numbers in spleen and liver at that time, whereas the specific immune system represented by T and B cells is functionally deficient. We previously reported enhanced activities in vitro of M phi (and PMN) from recipient animals in an early phase after allogeneic bone marrow transfer. We here demonstrate that these activities result in enhanced spontaneous resistance against Listeria monocytogenes in vivo: CFU of L. monocytogenes in spleen and liver 48 h after infection were about 1 or 2 to 4 log steps less than in untreated control mice of donor or host haplotype. This enhanced resistance decreased over the 4-mo period after marrow transfer. Preactivated M ...
Effects of intersegmental transfers on target location by proteins
We study a model for a protein searching for a target, using facilitated diffusion, on a DNA molecule confined in a finite volume. The model includes three distinct pathways for facilitated diffusion: (a) sliding - in which the protein diffuses along the contour of the DNA (b) jumping - where the protein travels between two sites along the DNA by three-dimensional diffusion, and finally (c) intersegmental transfer - which allows the protein to move from one site to another by transiently binding both at the same time. The typical search time is calculated using scaling arguments which are verified numerically. Our results suggest that the inclusion of intersegmental transfer (i) decreases the search time considerably (ii) makes the search time much more robust to variations in the parameters of the model and (iii) that the optimal search time occurs in a regime very different than that found for models which ignore ...
2008-01-01
Spontaneous transfer of gangliotetraosylceramide between phospholipid vesicles
Energy Technology Data Exchange (ETDEWEB)
The transfer kinetics of the neutral glycosphingolipid gangliotetraosylceramide (asialo-GM1) were investigated by monitoring tritiated asialo-GM1 movement from donor to acceptor vesicles. Two different methods were employed to separate donor and acceptor vesicles at desired time intervals. In one method, a negative charge was imparted to dipalmitoylphosphatidylcholine donor vesicles by including 10 mol% dipalmitoylphosphatidic acid. Donors were separated from neutral dipalmitoylphosphatidylcholine acceptor vesicles by ion-exchange chromatography. In the other method, small, unilamellar donor vesicles and large, unilamellar acceptor vesicles were coincubated at 45 degrees C and then separated at desired time intervals by molecular sieve chromatography. The majority of asialo-GM1 transfer to acceptor vesicles occurred as a slow first-order process with a half-time of about 24 days assuming that the relative concentration of asialo-GM1 in the ...
1985-07-16
International Nuclear Information System (INIS)
The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles within the respirable ...
1975-11-17
Glass-heat-pipe evacuated-tube solar collector
A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.
1981-08-06
International Nuclear Information System (INIS)
A comparison is made of the response of a count ratemeter and a pulse counter using the mathematical tool of the Z transform. Transform Z is used for the solution of the convolution integral interpreting the analog output of the count ratemeter used for recording characteristic radiation, excited in the moving beam. The comparison of count rates obtained by the count ratemeter during continuous analysis and the pulse counter during discontinuous measurement gave the transfer function of the count ratemeter in the actual range of count rate. Also discussed is the use of the transfer function for localizing concentration changes in the sample. The use of the described method is demonstrated on the determination of the tin content in tungsten using continuous radionuclide X-ray fluorescence analysis. (B.S.).
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
The measurements of the K X-ray intensity ratio I(K{sub {beta}})/I(K{sub {alpha}}) for the 17 elements Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Rb, Sr, Y, Zr, Nb and Mo have been done following ionization by 59.5keV {gamma}-rays from a {sup 241}Am point source. Ratios of emission probabilities of Auger electrons and the vacancy transfer coefficients have been extracted in terms of the intensity ratios. It is found that the present results agree well with earlier fitted values and the semi-empirical values.
2006-01-15
British Library Electronic Table of Contents (United Kingdom)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exc...
2010-01-01
Electronic structure, charge distribution and X-ray emission spectra of V_3Si
International Nuclear Information System (INIS)
Cluster calculations of the electronic structure and charge distribution in V_3Si have been performed using two different molecular orbital methods: a semiempirical LCAO and the MS X#alpha# model. The results are compared with X-ray emission spectra and band structure calculations. An analysis of the calculated electronic distribution reveals a charge transfer from Si-atoms to V-atoms, the additional charge on a V-atom being 0.6e (LCAO) and 0.4e (MS X#alpha# method). The results are in good agreement with experiment, which indicates that the cluster approach is adequate for the description of charge distributions and spectra characteristics of the A-15 compounds. (author).
Analysis of the omnium-g receiver
Energy Technology Data Exchange (ETDEWEB)
A thermal analysis of the Omnium-G receiver is presented and the technique is shown to be generally applicable to solar thermal receivers utilizing a directly heated thermal mass. The thermal loss coefficient, including reradiation losses, is calculated and shown to agree quite well with the experimentally measured thermal loss coefficient. The rate of heat transfer to the working fluid is also analyzed and the analysis is used to show that the Omnium-G receiver is well matched to the water/steam working fluid because the steam outlet temperature is almost the same as the receiver temperature. A general procedure for calculating receiver performance is presented. With this procedure, the energy delivery to any working fluid, the delivered temperature of the working fluid, and the pressure drop through the receiver can be determined. An example of the calculation is also presented.
1980-03-01
Energy Technology Data Exchange (ETDEWEB)
Calculating work-function modifications for flat-lying conjugated molecules on extended metal surfaces using density functional theory (DFT) is an extremely resource intensive task. This prevents fast screening of new molecules for their potential to optimize metal work functions for good electron or hole injection in organic electronic devices. We present a semi-classical model, which avoids that problem. This is achieved by identifying the dominant processes occurring at the interface between metal and adsorbate in the pinning-regime, which are then parameterizing their description using band-structure DFT calculations for a small training set With the resulting interdependent equations at hand, only simple gas-phase calculations are needed to predict the work-function changes induced by new molecules. The model is tested for ten molecules on three different metal surfaces, where it shows excellent agreement with ...
2010-07-01
Ultraviolet radiation in Finland
Energy Technology Data Exchange (ETDEWEB)
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
This paper reports the study results on the standard weather data necessary for simulation of PV power generation systems in fiscal 1994. In the study on the selection criterion of the standard weather data from the viewpoint of PV power generation systems, three typical years are used; a year with average solar radiation, and two years with extremely less and more solar radiation for safe simulation. The standard weather data are arranged for output calculation of PV power generation systems by selecting the most typical year based on long-term observation data. The data to be arranged are as follows; total, direct and scattered solar radiations incident upon a horizontal surface, solar radiation upon a slope surface, sunshine duration, air temperature, wind direction, wind velocity, amount of precipitation, and snow depth. For arrangement of the nationwide standard weather data, ...
1994-12-01
Energy Technology Data Exchange (ETDEWEB)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma ...
1983-01-01
International Nuclear Information System (INIS)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma ...
7871-01-01
Energy Technology Data Exchange (ETDEWEB)
The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating ...
2007-08-01
Simple calculation of daily photosynthesis by means of five photosynthesis-light equations
Energy Technology Data Exchange (ETDEWEB)
The performance of five well-known photosynthesis-light equations is compared by presenting a wide range of solutions in the form of dimensionless nomographs for the case where photosynthetically available radiation (PAR) reduces exponentially down the water column and is distributed sinusoidally through the photoperiod. These provide a simple means of calculating daily photosynthesis at any depth (e.g. at a benthic layer), or through a water column, avoiding the need to perform complex integrations. An examination is made of the accuracy of common approximate methods for calculating daily photosynthesis, assuming constant PAR. For optically deep water a modification is proposed to Talling's planimetric solution, to enable daily photosynthesis to be calculated more accurately, yet simply, over the whole range of possible PAR values. The errors induced by approximating the daily PAR distribution ...
1992-12-01
Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the ...
2007-07-01
International Nuclear Information System (INIS)
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work with tumour and ...
2006-01-01
Spontaneous Radiation Emission from Short, High Field Strength Insertion Devices
Energy Technology Data Exchange (ETDEWEB)
Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the ...
2005-09-15
Energy Technology Data Exchange (ETDEWEB)
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be ...
1984-01-01
Low dose effects - is the fear more dangerous than the radiation?
Energy Technology Data Exchange (ETDEWEB)
The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic ...
1996-01-01
Reference neutron transport calculation note for Korea nuclear power plants with 3-loop PWR reactors
Energy Technology Data Exchange (ETDEWEB)
Reactor pressure vessel (RPV) steels are subjected to neutron irradiation at a temperature of about 290 deg C. This radiation exposure alters the mechanical properties, leading to a shift of the brittle-to-ductile transition temperature toward higher temperatures and to a diminution of the rupture energy as determined by Charpy V-notch tests. This radiation embrittlement is one of the important aging factors of nuclear power plants. U.S. NRC recommended the basic requirements for the determination of the pressure vessel fluence by regulatory guide DG-1025 in order to reduce the uncertainty in the determination of neutron fluence calculation and measurements. The determination of the pressure vessel fluence is based on both calculations and measurements. The fluence prediction is made with a calculation and the measurements are used to qualify the calculational ...
1997-05-01
Application of the porous media model for the LWR process components
Energy Technology Data Exchange (ETDEWEB)
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling ...
2005-07-01
Particle and X-ray damage in pn-CCDs
Energy Technology Data Exchange (ETDEWEB)
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
2000-01-11
Energy Technology Data Exchange (ETDEWEB)
Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer ...
2009-05-26
Tritium bioassay and dosimetry at a CANDU reactors
Energy Technology Data Exchange (ETDEWEB)
Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.
1996-07-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this research was to determine improved thermal, epithermal, and fast fluxes and several responses at mechanical test surveillance location keys 2, 4, 5, and 7 of the pressure vessel of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) for the beginning of the fuel cycle. The purpose of the research was to provide essential flux data in support of radiation embrittlement studies of the pressure vessel shell and beam tubes at some of the important locations.
1993-11-01
Energy Technology Data Exchange (ETDEWEB)
Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).
1990-07-01
Radiation exposure of patients and operators during interventional radiology
International Nuclear Information System (INIS)
Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).
1986-01-01
Preparation of wood-polymer composites by using ionizing radiation
International Nuclear Information System (INIS)
Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).
1982-05-01
Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
1991-01-01
Measurement of stress in materials using chromium K/sub. beta. / radiation
Energy Technology Data Exchange (ETDEWEB)
Bragg peaks obtained in X-ray stress analysis studies are often asymmetric. The use of K/sub ..beta../ rather than K/sub ..cap alpha../ radiation simplifies the problem of peak location, as only one Bragg peak needs to be analysed. It is shown, however, that the common practice of fitting a parabola to the top 15% of the data in a Bragg peak in order to determine the peak position, when the fitted region is asymmetric, can lead to large errors in the calculated stress. Asymmetric pseudo-Lorentzian functions have been found to provide the most satisfactory fits.
1983-01-01
Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma
International Nuclear Information System (INIS)
The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)
2007-12-01
Estimated values of the genetic and somatic radiation exposure of the Bulgarian population in 1976
International Nuclear Information System (INIS)
The genetically and leukemia-significant doses (GSD and LSD) were calculated from the average gonad and bone marrow doses caused by the most frequently applied radiopharmaceuticals in Bulgaria in 1976. Because of the lack of information about the age groups of the patients examined assumptions have been made which led to estimated values of 0.97 mrad for GSD and 2.0 mrad for LSD which must be considered as the upper limit of the real GSD and LSD. The influence of the different radiopharmaceuticals on the average radiation exposure of the population is discussed. (author).
1976-01-01
Electronic structure of clusters of A-15 compounds with radiation induced defects
Energy Technology Data Exchange (ETDEWEB)
The electronic structure of the clusters (V/sub 3/Si/sub 4/)/sup 12 -/, (Nb/sub 3/Sn/sub 4/)/sup 12 -/(Mo/sub 3/Ge/sub 4/)/sup 15 -/ in crystalline V/sub 3/Si, Nb/sub 3/Sn, Mo/sub 3/Ge compounds is calculated by the Extended Hueckel method. The influence of different types of radiation induced defects on the density of states at the Fermi level (the anti-site defects, the displacement of atoms in linear chains, the vacancy-interstitial type defects) is considered.
1981-05-01
Electronic structure of clusters of A-15 compounds with radiation induced defects
International Nuclear Information System (INIS)
The electronic structure of the clusters [V_3Si_4]"1"2"-, [Nb_3Sn_4]"1"2"-[Mo_3Ge_4]"1"5"- in crystalline V_3Si, Nb_3Sn, Mo_3Ge compounds is calculated by the Extended Hueckel method. The influence of different types of radiation induced defects on the density of states at the Fermi level (the anti-site defects, the displacement of atoms in linear chains, the vacancy-interstitial type defects) is considered. (author).
Convection heat loss from a cavity receiver
Energy Technology Data Exchange (ETDEWEB)
The receiver whose convective heat loss test results are presented was designed to absorb 5 MW of solar energy, using a molten salt working fluid. During the tests, this receiver was brought to a temperature of about 343 C by a small group of heliostats. Total receiver heat loss due to emitted radiation, conduction and convection was first determined, and the convection loss was established by calculating the radiation and conduction losses analytically and subtracting their sum from the total. Losses due to convection are found to be 1.43 percent of the total heat input.
1984-02-01
Accumulation and distribution of "8"5Kr in rats exposed to "8"5Kr atmospheres
International Nuclear Information System (INIS)
Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.
1977-05-01
A marine compartment model for collective dose assessment of liquid radioactive effluents
International Nuclear Information System (INIS)
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).
1982-01-01
3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
1983-12-01
Thermal hydraulic analysis of nuclear reactors (THEA). THEA summary report
Energy Technology Data Exchange (ETDEWEB)
The project is focused on the thermal hydraulic analyses of nuclear power plants. Specific areas of research have been the modelling of heat transfer in horizontal steam generator in presence of non-condensable gas, and the development of tools for multidimensional two-phase flow simulations. The effect of non-condensable gas on the heat transfer in the horizontal steam generator (SG) has been studied by calculating with APROS the PACTEL experiments NCG-1 (air injection) and NCG-3 (helium injection). The work done for the two-phase flow model development consists of two parts; improving the solution algorithm of porous media code PORFLO, and adding a homogeneous two-phase model to the commercial CFD code Fluent. (orig.)
2004-07-01
Quantum corrections to the Larmor radiation formula in scalar electrodynamics
We use the semi-classical approximation in perturbative scalar quantum electrodynamics to calculate the quantum correction to the Larmor radiation formula to first order in Planck's constant in the non-relativistic approximation, choosing the initial state of the charged particle to be a momentum eigenstate. We calculate this correction in two cases: in the first case the charged particle is accelerated by a time-dependent but space-independent vector potential whereas in the second case it is accelerated by a time-independent vector potential which is a function of one spatial coordinate. We find that the corrections in these two cases are different even for a charged particle with the same classical motion. The correction in each case turns out to be non-local in time in contrast to the classical approximation.
2009-01-01
Gamma-rays and neutrinos from the pulsar wind nebulae
Energy Technology Data Exchange (ETDEWEB)
We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab ...
2005-08-01
British Library Electronic Table of Contents (United Kingdom)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...
2009-01-01
International Nuclear Information System (INIS)
Original investigations of ablation of minerals, fullerene-like compounds, polymers and complicated biological macromolecules under the action of submillimeter radiation of the free-electron laser (FEL) developed and built at Budker Institute of Nuclear Physics [V.P. Bolotin et al., First experiments on high-power Novosibirsk terahertz free-electron laser, Budker INP, 2005, p. 37
2007-05-21
Thermal performance of automotive aluminium plate radiator
Energy Technology Data Exchange (ETDEWEB)
The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of heat exchanger configurations that can help augment heat transfer whilst ...
2005-06-01
Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)
2004-11-30
International Nuclear Information System (INIS)
Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)
2004-11-30
Role of the radiation pressure gradient in giant and supergiant star evolution
Since some of the earliest evolutionary calculations it has been found that post main sequence stars become red giants (e.g. Sandage and Schwarzschild, 1952). However the exact physical processes that lead to and determine the rate of redward evolution are not completely understood. We hypothesized that the redward evolution might be due to an increase in radiation pressure somewhere in the star that causes the layers above it to be pushed outward, resulting in an expanded envelope and a cooler surface temperature. If the radiative luminosity somewhere in the star approached the Eddington limit, the outer layers would obviously expand. However, due to the presence of gas pressure, the critical value for expansion would be somewhat less than the Eddington limit.
1983-10-07
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
International Nuclear Information System (INIS)
In this paper experimental observations and a theoretical analysis of periodic radiation bursts and macropulse formation in the start-up phase of a free-electron laser (FEL) oscillator are presented. This microwave FEL uses a long pulse electron beam with a slowly decaying voltage. The output radiation consists of a superposition of bell-shaped macropulses, each of which is composed of a periodic sequence of short micropulses. The micropulses are separated by a cavity round-trip time. Each bell-shaped macropulse has a random start-up time and amplitude. The startup of the radiation macropulses is correlated with random current spikes on the continuous electron beam. The observed macropulse signal agrees with a theoretical calculation of the impulse response of the FEL oscillator when the shift in the FEL resonance frequency arising from the slow voltage drop of the electron beam is included in the ...
Dose consequences from a postulated criticality occurring in a low-level waste disposal facility
Energy Technology Data Exchange (ETDEWEB)
Evaluations were done to determine conditions that could permit nuclear criticality with fissile uranium in low-level waste (LLW) facilities and to estimate potential radiation exposures to personnel if there were such an accident. Simultaneous hydrogeochemical and nuclear criticality studies were done (1) to identity realistic scenarios for uranium migration and concentration increase at LLW disposal facilities, (2) to model groundwater transport of uranium and subsequent concentration via sorption or precipitation, (3) to evaluate the potential for nuclear criticality resulting from potential increases in uranium concentration over disposal limits, and (4) to estimate potential radiation exposures to personnel resulting from criticality consequences. This paper presents the details of the radiation exposure calculations relying on the conditions as determined from the preceding studies detailed in a ...
1997-12-01
International Nuclear Information System (INIS)
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of regulations concerning the ...
1988-01-01
Assessment and control of fetal exposure
Energy Technology Data Exchange (ETDEWEB)
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, ...
1991-10-01
Intensification of Harmonic Spontaneous Radiation with a Novel Undulator
We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessive current in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeV electrons taking K < 1, for spontaneous radiation emitted along the axis of the system. The emission at harmonics f > 1 is greatly enhanced for ...
1998-11-01
Steady-state film-boiling data in rod-bundle geometry and non-equilibrium correlation assessment
Energy Technology Data Exchange (ETDEWEB)
A series of 22 steady-state, rod bundle, dispersed flow film boiling experiments has been performed in the Thermal-Hydraulic Test Facility (THTF), a pressurized-water loop containing 64 full-length electrically heated rods. Test parameters in the upflow experiments cover a wide range of conditions typical of those which might be encountered during a nuclear reactor loss-of-coolant accident. Local equilibrium fluid conditions were calculated using mass and energy conservation considerations. Experimentally determined heat transfer coefficients were compared to several available film boiling heat transfer correlations: Dougall-Rohsenow, Groeneveld 5.7, Groeneveld-Delorme, Chen, Jones-Zuber, and Yoder-Rohsenow. The Groeneveld 5.7 correlation tended to predict the data better than any other correlation tested. The Dougall-Rohsenow correlation tends to overpredict the data while the Yoder-Rohsenow correlation predicted the data ...
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
The described heat transfer model supplies plausible results for the size distribution of active nucleation spots. For boiling states for which a comparison with measured bubble covering density is possible, that is for low boiling pressures and low heat flux densities, the bubble covering densities calculated by model on the basis of heat transfer measurements agree relatively well with the values observed. (orig.) [Deutsch] Das beschriebene Waermeuebergangsmodell liefert plausible Ergebnisse fuer die Groessenverteilung der aktiven Keimstellen. Fuer die Siedezustaende, fuer die ein Vergleich mit gemessenen Blasenbelegungsdichten moeglich ist, d.h. fuer niedrige Siededruecke und kleine Waermestromdichten, stimmen die aufgrund der Waermeuebergangsmessungen mit dem Modell berechneten Blasenbelegungsdichten verhaeltnismaessig gut mit den beobachteten Werten ueberein. (orig.)
1992-02-15
Development of fire simulation models for radiative heat transfer and probabilistic risk assessment
Energy Technology Data Exchange (ETDEWEB)
An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical applications, advanced ...
2008-07-01
International Nuclear Information System (INIS)
Full text: The principal nuclear design tools available to the shielding designer include diffusion approximation, transport theory, and Monte Carlo techniques. Full transport theory or Monte Carlo methods are routinely used for shielding analyses, where penetration investigations are more sensitive to directional aspects. However, the aim of this paper is to illustrate the coupled neutron-gamma Albedo method particularly as applied to problems of shielding analysis. The multigroup Albedo method is applied to coupled neutron-gamma radiations considering 'n' neutron energy groups and 'g' gamma energy groups to estimate the probabilities of transmission through, absorption in, and reflection from shieldings composed by multiple material layers, 'm' slabs, in which no fission occurs. In this study, these energy groups were selected in order to minimize upscattering effects of the radiation from lower energy groups to higher energy groups. However, ...
Large Eddy Simulation for Heat Transfer Prediction in a Gas ...
... turbine blade heat-transfer and study the heat-transfer augmentation in idealized geometry and its ... responsible for heat transfer augmentation. ...
2007-03-30
International Nuclear Information System (INIS)
Objective: To apply the obtained results from 3 stages of research in Chinese radiation protection field. Methods: Based on the identification of physical, chemical and biological qualities for element and its radionuclides under equilibrium condition, main application of these results in Chinese radiation protection field have been discussed by using reported methods in literature. Results: Based on developing elemental reference values of organs or tissues, whole body burdens and their distribution for Chinese Reference Man, discussed in the above 3 articles, current dietary elemental intakes of 42 elements have been updated, and related basis for certain important parameters of bio-kinetic model for use in radiation protection (for example, f_l, T_e and T_b) have been provided. The internal doses from primordial radionuclides and transfer coefficients of elements from environment into the critical ...
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
The following paper is focused on the numerical modelling of the transient radon diffusion through radon-proof membranes during the measurement of their radon diffusion coefficient. The major aim of such numerical modelling is to increase the accuracy of radon diffusion coefficients derived from the measured data sets. The developed complex ''transient'' numerical model is able to calculate the radon diffusion coefficient with sufficient accuracy from almost any data set - even from a short-time measurement with a non-linear course of results. This numerical model can also be used for various analyses of transient radon transfer processes (e.g. for the calculation of radon distribution curves within the membrane). The following paper presents governing equations for the simulation model, together with a brief description of algorithms incorporated in the newly developed software package, ...
2009-06-15
TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams
International Nuclear Information System (INIS)
A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in ...
2010-03-11
Changes of magnetization transfer ratio according to rat brain development
International Nuclear Information System (INIS)
We assessed the age-related changes in magnetization transfer ratio (MTR) value and the ratio of water content in rat brain (frontal lobe and pons) during normal development. All studies were done on 42 normal Wistar rats. MTR was calculated by using the equation (M_o_f_f-M_o_n)/M_o_f_f, where M_o_f_f and M_o_n were the measured signal intensities on the conventional and MT-prepared SPGR images, respectively. The ratios of water content were measured by comparing the wet weight with the dry weight of the frontal lobe and the pons, which were extracted from a rat brain soon after MTR measurements. The ratio of water content was calculated by using the equation 100 x (wet weight-dry weight)/wet weight (%). The ratio of water content decreased markedly during the first 30 days, but the decrease was very slight there after both in the frontal lobe and the pons. The change in MTR was similar to that of the ratio of water ...
International Nuclear Information System (INIS)
Presented here is the calculation of radionuclide concentration in gaseous effluents from the Daya Bay Nuclear Power Plant by using the Gaussian model, based on the analysis of the radionuclides in gaseous effluents and based on the measured wind field in the area of Guangdong province in November 2005. The calculating results about the relative concentration distribution of the radionuclides in Guangdong province, especially in Daya Bay, Shengzheng, Zhuhai and Guangzhou, are obtained. These results can provide reference data for the effect of radiation on the environment of Guangdong province under normal conditions of operation of the Daya Bay Nuclear Power Plant. It can also provide reference data for monitoring possible nuclear incidents in nuclear power plants. (authors)
2007-07-01
International Nuclear Information System (INIS)
Presented here is the calculation of the diffusion of radionuclides from the Daya Bay Nuclear Power Plant under normal operation on the basis of Gaussian model. The model is modified partially considering practical situation, and monitoring meteorological data are adopted. By using the AIRDOS-EPA computer code, the average annual ground-level concentration distribution of radionuclides from Daya Bay Nuclear Power Plant in 2001 was obtained, the atmospheric dispersion factor and ground deposition rate were also acquired. These calculated results can provide information for understanding the effect on radiation environment due to Daya Bay Nuclear Power Plant under normal operation. (authors)
2007-11-01
New methods for electronic structure calculations
Energy Technology Data Exchange (ETDEWEB)
This thesis consists of five chapters, each of which is a self-contained unit. The first chapter overviews methods for electronic-structure calculations. Chapter 2 introduces a new method to generate a rapidly converging configuration expansion. The approach iteratively combines (1) a least-squares fitting of a configuration expansion to a many-body wave function with (2) a transfer-matrix method for projecting out the ground state. Results are shown to be equivalent to multiconfiguration Hartree-Fock. Results from test calculations are given for a simple finite difference model of the helium atom. In Chapter 3 the use of the finite-element method in electronic structure calculations is discussed. Chapters 4 and 5 discuss developments in Monte Carlo methods based on Hubbard-Stratonovich transformations. Chapter 4 introduces a canonical ensemble formulation of the method, which is more appropriate than ...
1988-01-01
FT-IR spectroscopic studies of polycyclic aromatic hydrocarbons
International Nuclear Information System (INIS)
Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared absorption coefficients instead of those ...
1990-04-01
The calibration of sub-Coulomb heavy ion proton transfer reactions
Energy Technology Data Exchange (ETDEWEB)
Measurements were made of the cross sections for the /sup 27/Al(/sup 16/O,/sup 15/N)/sup 28/Si, /sup 89/Y(/sup 15/N,/sup 16/O)/sup 88/Sr and /sup 89/Y(/sup 27/Al,/sup 28/Si)/sup 88/Sr reactions at energies near and below the Coulomb barrier. The first reaction required separate measurements of the transfer to elastic cross section ratio for particular charge states, the charge state distribution for /sup 27/Al and /sup 28/Si ions, and the absolute elastic scattering cross section for the /sup 27/Al + /sup 16/O system. The ratio measurement required the combined use of two relatively new scientific instruments: the momentum filter and the Bragg curve spectrometer. The latter two transfer measurements were performed using the same setup involving surface barrier detectors at backward angles. Additional elastic scattering data for the /sup 15/N + /sup 28/Si, /sup 89/Y + /sup 15/N, /sup 89/Sr + /sup 27/Al, and /sup 88/Sr + /sup 28/Si systems was ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The ...
2002-07-01
Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method
International Nuclear Information System (INIS)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The ...
2002-01-01
Thermal performance simulation of a solar cavity receiver under windy conditions
British Library Electronic Table of Contents (United Kingdom)
Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Theoretical investigations of fatty acids as a phase change material (PCM) for energy storage system have been conducted in this study. The selected fatty acids were capric acid, lauric acid, myristic acid, palmitic acid and stearic acid. For the two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Glass, stainless steel, tin, aluminium mixed, aluminium and copper were used as heat exchanger materials in the numerical calculations. Theoretical results show that capric acid was found good compatibility with latent heat storage system. The large value of thermal conductivity of heat exchanger materials did not make significant contribution on the melt fraction. (author)
2005-11-01
Exclusive ?0 electroproduction on transversely polarized protons
International Nuclear Information System (INIS)
The exclusive electroproduction of ?0 mesons was studied with the HERMES spectrometer at the DESY laboratory by scattering 27.6 GeV positron and electron beams off a transversely polarized hydrogen target. Spin density matrix elements for this process were determined from the measured production- and decay-angle distributions of the produced ?0 mesons. These matrix elements embody information on helicity transfer and the validity of s-channel helicity conservation in the case of a transversely polarized target. From the spin density matrix elements, the leading-twist term in the single-spin asymmetry was calculated separately for longitudinally and transversely polarized ?0 mesons. Neglecting s-channel helicity changing matrix elements, results for the former can be compared to calculations based on generalized parton distributions, which are sensitive to the contribution of the total angular momentum of the quarks to the ...
2009-08-17
Calculations relating to two experiments that demonstrate coherent control of preformed rubidium-85 molecules in a magneto-optical trap using ultrafast laser pulses are presented. In the first experiment, it is shown that pre-associated molecules in an incoherent mixture of states can be made to oscillate coherently using a single ultrafast pulse. A novel mechanism that can transfer molecular population to more deeply bound vibrational levels is used in the second. Optimal parameters of the control pulse are presented for the application of the mechanism to molecules in a magneto-optical trap. The calculations make use of an experimental determination of the initial state of molecules photoassociated by the trapping lasers in the magneto-optical trap and use shaped pulses consistent with a standard ultrafast laser system.
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
We report the first band structure calculations of the quasi-one-dimensional [MnTPP][TCNE] compounds (TPP?=?meso-tetraphenylporphyrinato, TCNE?=?tetracyanoethylene), based on Density Functional Theory (DFT) methods, in order to interpret the magnetic ordering in these prototypic systems. We compare and contrast the results of broken-symmetry DFT calculations for extended systems, with periodic boundary conditions, and for finite systems, magnetic dimers modeling the actual molecular magnets. By varying systematically the main angles, we are able to determine the geometry dependence of the exchange interaction. Structure?properties correlations in these charge-transfer salts reveal the determinant role of the Mn-(N?C)TCNE bond angle on the strength of the ferrimagnetic coupling between the ...
2011-01-01
Bulk and surface electronic structure of hexagonal boron nitride
International Nuclear Information System (INIS)
Accurate full-potential self-consistent linearized augmented-plane-wave (FLAPW) calculations have been carried out for hexagonal boron nitride. The resulting energy-band structure indicates that this material is an indirect-gap insulator and shows the existence of two unoccupied interlayer bands, similar to those found in graphite and graphite intercalation compounds. Chemical bonding is mainly covalent, with a small charge transfer towards the nitrogen atoms. Moreover, model-potential calculations, based on first-principles FLAPW wave functions and potentials, have been used to study slabs of thickness up to 35 layers. Contrary to the case of graphite, our results do not provide evidence of surface states associated with the interlayer bands.
Energy Technology Data Exchange (ETDEWEB)
Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
Electronic structure of the Ru(0001) surface
Energy Technology Data Exchange (ETDEWEB)
This paper deals with the electronic structure of ruthenium. Synchrotron radiation in the range from 15 to 45 eV and angle-resolved ultraviolet photoemission are used to map the energies of the electronic states. The Fermi surface of Ru is determined using angle-resolved ultraviolet photoemission spectroscopy. The experimental results are compared with calculated photoemission spectra obtained within the framework of the one-step model of photoemission. (author)
2000-03-13
Electron-ion recombination of neutral iron
Energy Technology Data Exchange (ETDEWEB)
The total and state-specific electron-ion recombination rate coefficients are obtained for FeI. The calculations are carried out using a new ab initio method that incorporates both the radiative and the dielectronic recombination processes in an unified and self-consistent manner. The computations employ the close coupling approximation and the R-matrix method from atomic collision theory. A 52 state close coupling eigenfunction expansion dominated by the states of the ground 3d{sup 6}4s and excited 3d{sup 7}, 3d{sup 6}4p, 3d{sup 5}4s{sup 2}, and 3d{sup 5}4s4p configurations of FeII are used in the present calculations. The important electron correlation and radiation damping effects are included via explicit coupling of autoionization and radiative channels. This is the first detailed atomic calculation for the recombination rates for FeI. The present rates are ...
1997-04-01
Energy Technology Data Exchange (ETDEWEB)
A comment on the letter by T. Kajino and A. Arima Phys. Rev. Lett. 52, 739 (1984).
1984-07-23
Using radiation: harder, tougher and more stable woods
International Nuclear Information System (INIS)
The general characteristics of radiation processing and its main applications of interest in Chile are described, with particular reference to the production of wood-plastic composites (WPC). The process itself and the technical characteristics of the resulting product are explained for products that demand an aesthetic appearance, warmth, toughness and durability, as in the flooring industry. Certain domestic wood products could receive a boost in quality by using this process, making them more competitive in demanding export markets. These products could open new markets, serving as substitutes, for example, for carpets and tiles. This would be highly convenient for Chile, considering the big supply of wood for industrial consumption that the country will have in the coming decade. Because of this situation two Chilean technology institutes, the Chilean Nuclear Energy Commission and INTEC-CHILE, are jointly working on a project that aims to increase the quality ...
1998-10-01
International Nuclear Information System (INIS)
Research and development and other activities of the various constituent units of Department of Atomic Energy (DAE) and also of the institution aided by DAE for the year 2005-2006 are reported. The various constituents units of DAE consist of nuclear research centres, nuclear power stations, fuel reprocessing and heavy water plants, nuclear fuel fabrication facilities, electronic and instrumentation production organisations, atomic mineral processing units and other nuclear installations. The activities of DAE cover the whole gamut of nuclear fuel cycle, research and development in nuclear science and reactor technology, applications of radiation and radioisotopes, radiation protection, research and development in front line areas such as robotics, lasers, mathematics and computational sciences. International research collaborations like CERN-DAE collaboration were completed by BARC. These activities are described broadly under: executive ...
Spectroscopy of neutron-rich Fe isotopes populated in the "6"4Ni+"2"3"8U reaction
International Nuclear Information System (INIS)
The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.
2007-09-01
Principle, classification and functions of geochemical modeling codes
International Nuclear Information System (INIS)
Geochemical model is a kind of concept model which describes geochemical processes by means of chemical reaction equations and mathematical formula, and the software based on the concept model are called geochemical modeling code. Geochemical modeling codes can be divided into three categories: mass equilibrium, mass transfer and mass transport code. The major functions of geochemical codes include the calculation of forms of occurrence of elements, the prediction of direction of various geochemical reaction, the dissolution and precipitation of elements, the pH and Eh value, the rate and path of geochemical reaction in aqueous solution.
Natural convection cooling of circumferentially finned transport casks
International Nuclear Information System (INIS)
It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.
1983-12-01
Design parameters for tube cavity receivers in solar power plants
Energy Technology Data Exchange (ETDEWEB)
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
1981-01-01
Denaturation of Heterogeneous DNA
The effect of pair-binding energy variations on the denaturation of double stranded DNAs is investigated. Using a two-parameter renormalization group (RG) analysis and extensive transfer matrix calculations, we find a random quenched-in variations to be marginally irrelevant, indicating that the system is self-averaging at the transition. The effect of a recently-proposed variable backbone stiffness is also investigated. Although irrelevant in the RG sense, it dramatically amplifies the randomness, leading to the appearance of ``multi-step melting'' for realistic sequences. These results are relevant to the adsorption of random heteropolymers and the wetting of disordered substrates.
1997-01-01
Conjugate parallel-flowing free and forced convection boundary layers on vertical wall sides
Energy Technology Data Exchange (ETDEWEB)
The paper describes an analytical study of two parallel-flowing boundary layers of free and forced convection modes on the facing sides of a vertical thin wall. The two layers are analyzed separately within the framework of boundary layer theory, and coupled by the matching conditions at wall. Numerical data are obtained for a wide range of a dimensionless conjugation parameter {zeta} relating the heat transfer effectiveness of two convection modes. Based on these data, an expression for calculating the conjugate mean Nusselt number as a function of {zeta}-parameter is found by means of a curve-fitting method. (orig.)
2003-02-01
Assessing radiologic risk for population due to human activities
International Nuclear Information System (INIS)
The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...
2002-09-06
Mercury-free fluorescent lighting
Energy Technology Data Exchange (ETDEWEB)
A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm using a calibrated VUV ...
1996-05-01
Improvement of top shield analysis technology for CANDU 6 reactor
Energy Technology Data Exchange (ETDEWEB)
As for Wolsung NPP unit 1, radiation shielding analysis was performed by using neutron diffusion codes, one-dimensional discrete ordinates code ANISN, and analytical methods. But for Wolsung NPP unit 2, 3, and 4, two-dimensional discrete ordinates code DOT substituted for neutron diffusion codes. In other words, the method of analysis and computer codes used for radiation shielding of CANDU 6 type reactor have been improved. Recently Monte Carlo MCNP code has been widely utilized in the field of radiation physics and other radiation related areas because it can describe an object sophisticately by use of three-dimensional modelling and can adopt continuous energy cross-section library. Nowadays Monte Carlo method has been reported to be competitive to discrete ordinate method in the field of radiation shielding and the former has been known to be superior to the latter for complex ...
1996-07-01
Concepts in radiation protection
International Nuclear Information System (INIS)
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the dose limit diminished ...
1996-01-01
International Nuclear Information System (INIS)
In this paper, a phenomenological model of the thermal hydraulics of convective boiling in the post-critical-heat-flux (post-CHF) regime is developed and discussed. The model was implemented in the TRAC-PF1/MOD2 computer code (an advanced best-estimate computer program written for the analysis of pressurized water reactor systems). The model was built around the determination of flow regimes downstream of the quench front. The regimes were determined from the flow-regime map suggested by Ishii and his coworkers. Heat transfer in the transition boiling region was formulated as a position-dependent model. The propagation of the CHF point was strongly dependent on the length of the transition boiling region. Wall-to-fluid film boiling heat transfer was considered to consist of two components: first, a wall-to-vapor convective heat-transfer portion and, second, a wall-to-liquid heat transfer representing ...
1983-10-14
Dose planning and dose delivery in radiation therapy
International Nuclear Information System (INIS)
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the ...
2008-08-01
International Nuclear Information System (INIS)
In this thesis the rate constants for a number of radical reactions in aqueous solution have been studied in a wide temperature range. The reactions of H with H_2O_2, OH and HO_2 and the reactions of HO_2 with OH, Fe"2"+ and Cu"2"+ have been studied. For each reaction rate constants have been determined as a function of temperature using the technique of high temperature, high pressure (HTP) pulse radiolysis. The rate constants were obtained by fitting a kinetic computer model to the experimental data. From an Arrhenius plot the activation energy of each reaction was determined. The data determined in this way are important for modeling of radiolysis in nuclear light water reactors. A previously developed model for calculation of the effect of water radiolysis products on oxidation and dissolution of spent nuclear fuel has been improved. In the new model, called TraRaMo, simultaneous transport by diffusion and chemical reactions induced by radiolysis can be ...
2003-01-01
International Nuclear Information System (INIS)
Ultraviolet (UV) upconversion (UC) luminescence in Yb3+/Er3+-codoped yttrium oxide (Y2O3) nanocrystals can be enhanced by orders of magnitude via tridoping further with Li+ ions under diode laser excitation of 970 nm. Sensitized three-photon UC radiations at 390 and 409 nm, corresponding to the 4G11/2?4I15/2 and 4H9/2?4I15/2 of Er3+ ions, respectively, present an enhancement time of about 33 times, which is larger than the 24 times enhancement for the UC green radiation. The UV UC radiation at 320 nm that corresponds to the 2P3/2?4I15/2 of Er3+ ions has also been greatly enhanced. Theoretical calculations interpret that all the observed enhancement times of UV UC radiations arise from the prolonged lifetimes of their intermediate states.
2009-03-01
International Nuclear Information System (INIS)
Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved ...
1983-01-01
Intensification of harmonic spontaneous radiation with a novel undulator
International Nuclear Information System (INIS)
We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessivecurrent in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeV electrons taking K1 is greatly enhanced for the approximate square-wave magnetic profile: the ratio of the power emitted at f=5 by the square-wave undulator to that of the ...
1999-07-01
Bomb "1"4C and human radiation burden
International Nuclear Information System (INIS)
Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbed dose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially produced "1"4C calculated using the assumptions stated is certainly ...
International Nuclear Information System (INIS)
To respond to an increase of social problems concerning orphan sources in Japan, a working group was formed in the Japan Health Physics Society. In this working group, we investigated how to prevent acute radiation hazard or social panic regarding orphan sources in scrap metal and detection system for orphan sources brought into scrap yards before recycle. For detection system in a scrap yard we conducted an experiment on detectability of monitoring instrument using a radiation source mixed in scrap metal on a truck. The result showed that it was not easy to detect even a high-level source if it was shielded by scrap metal. We also estimated detection limits for radioactive materials in scrap metal by calculation that was validated with experimental data. We summarized present status about orphan sources in Japan and proposed a categorization of orphan sources according to dose rates to deal with unknown sources in a scrap ...
2002-10-20
Energy Technology Data Exchange (ETDEWEB)
A phenomenological model of the heat transfer in direct injection diesel engines was developed. Utilizing the thermodynamic results of a combustion model as an input, the model is able to predict the temporal variation of the heat losses from the cylinder gas to the cylinder walls. Additionally, the division into isothermal combustion chamber subsurfaces allows the consideration of the spatial variation of the wall heat fluxes. The physical mechanisms such as flow dependent convection, heat radiation due to hot soot particles and isolation effects of deposited soot layers are described in detail. Thus the effects of these mechanisms on the overall heat transfer can be studied. The heat transfer model was verified successfully by the comparison to measured wall heat fluxes in a single-cylinder direct injection diesel engine. It is shown that the effects of engine speed and load, turbocharging and soot ...
2000-07-01
Energy transfer in Y3Al5O12:Ce3+, Pr3+ and CaMoO4:Sm3+, Eu3+ phosphors
International Nuclear Information System (INIS)
Non-radiative energy transfers (ET) from Ce3+ to Pr3+ in Y3Al5O12:Ce3+, Pr3+ and from Sm3+ to Eu3+ in CaMoO4:Sm3+, Eu3+ are studied based on photoluminescence spectroscopy and fluorescence decay patterns. The result indicates an electric dipole-dipole interaction that governs ET in the LED phosphors. For Ce3+ concentration of 0.01 in YAG:Ce3+, Pr3+, the rate constant and critical distance are evaluated to be 4.5x10-36 cm6 s-1 and 0.81 nm, respectively. An increase in the red emission line of Pr3+ relative to the yellow emission band of Ce3+, on increasing Ce3+ concentration is observed. This behavior is attributed to the increase of spectral overlap integrals between Ce3+ emission and Pr3+ excitation due to the fact that the yellow band shifts to the red spectral side with increasing Ce3+ concentration. In CaMoO4:Sm3+, Eu3+, Sm3+-Eu3+ transfer occurs from 4G5/2 of Sm3+ to 5D0 of Eu3+. The rate constant of 8.5x10-40 cm6 s-1 ...
2011-03-01
Energy Technology Data Exchange (ETDEWEB)
Shielding calculations for neutron-gamma radiation are usually done by using the full Theory of Transport or the Monte Carlo Techniques. After some works based on the Albedo Method, the shielding calculations for neutron-gamma radiation have a reliable tool with great didactical value which shows its clarity and simplicity for the resolution of cases that involve neutrons and photon shielding in nonmultiplying media. The excellent results of these works have motivated the elaboration and the development of this study that will be presented in this dissertation. The balance of a neutronic current entering a shield of two layers considering the coupling neutron-gamma will be determined by the Albedo Method. The shield will be composed of a layer of iron and another one of manganese with 10 cm of thickness each. The arrays of the materials coefficients will be obtained from the ANISN code. ANISN is a one ...
2001-07-01
Multigroup Albedo Method applied to coupled neutron-gamma radiations shielding
International Nuclear Information System (INIS)
Shielding calculations for neutron-gamma radiation are usually done by using the full Theory of Transport or the Monte Carlo Techniques. After some works based on the Albedo Method, the shielding calculations for neutron-gamma radiation have a reliable tool with great didactical value which shows its clarity and simplicity for the resolution of cases that involve neutrons and photon shielding in nonmultiplying media. The excellent results of these works have motivated the elaboration and the development of this study that will be presented in this dissertation. The balance of a neutronic current entering a shield of two layers considering the coupling neutron-gamma will be determined by the Albedo Method. The shield will be composed of a layer of iron and another one of manganese with 10 cm of thickness each. The arrays of the materials coefficients will be obtained from the ANISN code. ANISN is a one ...
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
The Nuclear Regulatory Commission (NRC) has sponsored several studies to identify and quantify, through the use of models, the potential health effects of accidental releases of radionuclides from nuclear power plants. The Reactor Safety Study provided the basis for most of the earlier estimates related to these health effects. Subsequent efforts by NRC-supported groups resulted in improved health effects models that were published in the report entitled {open_quotes}Health Effects Models for Nuclear Power Plant Consequence Analysis{close_quotes}, NUREG/CR-4214, 1985 and revised further in the 1989 report NUREG/CR-4214, Rev. 1, Part 2. The health effects models presented in the 1989 NUREG/CR-4214 report were developed for exposure to low-linear energy transfer (LET) (beta and gamma) radiation based on the best scientific information available at that time. Since the 1989 report was published, two addenda to that report have been prepared to (1) ...
1993-05-01
Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects
Energy Technology Data Exchange (ETDEWEB)
Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...
1996-12-31
Variability of infrared stimulated luminescence properties from fractured feldspar grains
Energy Technology Data Exchange (ETDEWEB)
A series of OSL properties of fragments from split feldspar grains have been investigated. These are (1) the response to a radiation dose, (2) the recycling of corrected induced luminescence (L{sub i}/T{sub i}), (3) the corrected natural luminescence (L{sub N}/T{sub N}), (4) the corrected thermal transfer luminescence (termed herein L{sub tt}/T{sub tt}) and, (5) the rate of anomalous fading ('g'). It was found that the parameters of different parts of the same grain are the same. The relative uncertainty, at the 2 sigma level, at which we can claim that the measured parameters are correlated, is generally less than 5% but is ca 40% for the anomalous fading rate due to measurement uncertainty. For young partially bleached sediments, the result is that one could use one fragment to evaluate the equivalent dose and another to assess the contribution of thermal transfer resulting from preheating the natural ...
2003-10-01
Energy Technology Data Exchange (ETDEWEB)
The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general ...
1994-03-01
Experimental Seminar on Nuclear Energy for Teachers
Energy Technology Data Exchange (ETDEWEB)
`Experimental Seminar on Nuclear Energy for Teachers` was conducted and sponsored by the Science and Technology Agency. And in order to understand nuclear energy properly through lectures and experiments with good results inclass, the seminar carried out for teachers of high schools and junior high schools by the Nuclear Technology and Education Center (NuTEC), Japan Atomic Energy Research Institute in 1990 FY to 1997 FY. In this report, details of the seminars in the above period are described and No.1 to 17 of Communication Letters of Experimental Seminar on Nuclear Energy` started at 1992 FY are described also. These letters were prepared for attendant follow-up program. And programs of recent seminars, future`s seminars, impressions and comments from attendants, reports from actual classes and others are described in these letters and they are very useful for educational classes on nuclear energy by other teachers. Therefore contents of the letters are listed and easy to refer. A ...
1999-02-01
Fully relativistic analysis of the absorption spectra of Ca_3Sc_2Ge_3O_1_2:Ni"2"+
International Nuclear Information System (INIS)
Systematic analysis of the energy level schemes, ground state absorption (GSA) and covalency effects for the Ni"2"+ ion in Ca_3Sc_2Ge_3O_1_2 was performed. The recently developed first-principles approach to the analysis of the absorption spectra of impurity ions in crystals based on the discrete variational multi-electron method (DV-ME) [K. Ogasawara et al., Phys. Rev. B 64, 115413 (2001)] was used in the calculations. As a result, complete energy level schemes of Ni"2"+ and its absorption spectra at both possible crystallographic positions (distorted octahedral Sc"3"+ and tetrahedral Ge"4"+ positions) were calculated, assigned and compared with experimental data. Energies of the charge transfer (CT) transitions for both positions are estimated. Numerical contributions of all possible electron configurations into the calculated energy states were determined. By performing analysis of the molecular ...
2006-10-01
International Nuclear Information System (INIS)
The Department of Nuclear Engineering and Fluid Mechanics in the University of the Basque Country (UPV-EHU), has done calculations for the proposed benchmark problem, in the frame of the 11th international meeting of the IAHR working group on advanced nuclear reactors thermal-hydraulics (Obninsk-Russian Federation, 5-9 July 2004). The purpose of the benchmark is to compare experimental and analytical results of some experiments carried out in the State Scientific Center of Russian Federation 'Institute of Physics and Power Engineering' (SSC RF IPPE). These experiments were held to research the cooling of pin bundles by liquid metals in reference to the core of Nuclear Reactors such as BREST. The analytical results have been done with the Computational Fluid Dynamics (CFD) code FLUENT. Temperature and velocity fields are the main variables considered for the comparison, and some assumptions has been made in order to simplify a complicate geometry with grids and ...
2004-07-05
International Nuclear Information System (INIS)
The "2"0 "2"1 "2"2Ne("6Li, d)"2"4 "2"5 "2"6Mg reactions have been studied at a bombarding energy of 32 MeV. Alpha particle spectroscopic strengths have been extracted for several low-lying levels by a finite-range distorted wave analysis. These are compared with theoretical predictions. The agreement is good both for relative strengths to different levels within a nucleus and for ground-state strengths relative to the "1"6O("6Li, d) result. Strengths calculated using eigenfunctions determined in large shell-model computations agree well with pure symmetry SU(3) predictions. The "2"1Ne("6Li, d) angular distributions for transitions to the ground-state band of "2"5Mg are characterized by the lower of the two L-transfers allowed for populating each level. For the 3"+(5.24 MeV) unnatural parity level in "2"4Mg, a two-step calculation gives a better account of the data than does a compound nuclear ...
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Radiation technology of wood-plastic composite materials
International Nuclear Information System (INIS)
... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.
1981-10-02
Radiation chloration sulfochloration and sulfooxidation of organic compounds
International Nuclear Information System (INIS)
... halogenation ionizing radiations kinetics radiations reaction kinetics
British Library Electronic Table of Contents (United Kingdom)
We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.
2011-01-01
International Nuclear Information System (INIS)
A high-density gas jet supersonic nozzle is reported in this paper. The jitter and actuation time of the nozzle is determined by the pin discharge and laser spark radiation respectively. The jitter time of the nozzle is within 10 ?s with the backing pressure as high as 25 bar. With a nanosecond laser pulse focused on the gas jet about 1 mm below the nozzle, the actuation time is calculated to be about 15 ms by detecting the laser produced spark radiation, which reveals the existence of the gas jet and the relative gas density evolving with time. Consequently the gas density is estimated to be well above 1019 cm-3, compared with theoretical simulations from the nozzle parameters.
2006-07-01
Spontaneous excitation of an accelerated atom in a spacetime with a reflecting plane boundary
We study a two-level atom in interaction with a real massless scalar quantum field in a spacetime with a reflecting boundary. The presence of the boundary modifies the quantum fluctuations of the scalar field, which in turn modifies the radiative properties of atoms. We calculate the rate of change of the mean atomic energy of the atom for both inertial motion and uniform acceleration. It is found that the modifications induced by the presence of a boundary make the spontaneous radiation rate of an excited inertial atom oscillate near the boundary and this oscillatory behavior may offer a possible opportunity for experimental tests for geometrical (boundary) effects in flat spacetime. While for accelerated atoms, the transitions from ground states to excited states are found to be possible even in a vacuum due to changes in the vacuum fluctuations induced by both the presence of the boundary and the acceleration of atoms, ...
2005-09-15
International Nuclear Information System (INIS)
Results of experimental investigation into radiation electromagnetic effect (REM) in samples of germanium crystals under approximately 40 MeV #alpha#-particle irradiation in a cyclotron are presented. A high level of excitation, volumetric character of generation of non-equilibrium carriers and formation of defects as well as the form of their spatial distribution are shown to result in some peculiarities of the EMF of the REM effect on the particle flux, fluence and sample parameters. Agreement of theoretical calculations, conducted with account of specificity of #alpha#-particle interaction with a crystal, and experimental data is obtained. It is revealed that the REM effect can be applied in obtaining data on spatial distribution of non-equilibrium carrier concentrations along the particle trajectory in the crystal.
Optical properties and up-conversion of Pr"3"+ doped CdS nanoparticles in sol-gel glasses
International Nuclear Information System (INIS)
Silica glasses containing Pr"3"+ with and without CdS nanoparticles were prepared by sol-gel technique. The influence of CdS nanoparticles on Pr"3"+ doped glass was studied by absorption, photoluminescence and up-conversion. From the measured intensities of various absorption bands of these glasses, the Judd-Ofelt parameters ?_2, ?_4 and ?_6 have been evaluated. The radiative transition probability (A), radiative lifetime (?_R), branching ratio (?_R) and integrated emission cross-section (?_P) were calculated from excited states of "3P_1 and "3P_0 levels. The up-conversion emissions were found in the green, orange and red regions under 800 nm excitation with peaks 559, 612 and 688 nm respectively. On excitation with 370 nm also leads to similar green, orange and red regions.
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.
1985-03-01
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...
2007-01-01
Effects of stress on radiation hardening and microstructural evolution in A533B steel
British Library Electronic Table of Contents (United Kingdom)
Bent specimens of A533B steel (0.16wt% Cu) were irradiated at 290degreeC to 1dpa with 6.4MeV Fe3+ ions. Calculated tensile stresses at the irradiated surface were set to 0, 250, 500 and 750MPa. The specimens were subjected to hardness measurements, transmission electron microscopy (TEM) observations and three-dimensional atom probe (3DAP) analysis. The radiation-induced hardening decreased with increasing stress to 500MPa which was near the yield strength. TEM and 3DAP results showed that well-defined dislocation loops and solute clusters were formed. The diameter of dislocation loops increased and the number density decreased when the stress was applied, whereas the diameter and number density of solute clusters decreased. The hardening was mainly attributed to solute cluster formation. A...
2010-01-01
International Nuclear Information System (INIS)
Lupinus albus L. plants were grown from seeds and irradiated at various stages of development with acute or chronic gamma rays. All plants were greenhouse grown (pre- and post-irradiation) and allowed to proceed through their normal growth cycle. The purpose of these experiments was to establish a Plactochron Index for Lupinus albus L. and to determine the effects of acute and chronic irradiation on development at the macro and microscopic levels. A Plastochron Index was calculated and used as an indirect time scale to evaluate the effects of gamma rays from a common base line. Acute radiation treatment lasted for a period of a few days, whereas chronic treatment was initiated at the seedling stage and lasted for the entire growth season. Vegetative plants were used to study the effects of acute radiation exposure on apical meristem morphology, Plastochron Index, phyllatoxis and gross morphology.
1980-01-01
Deep-level defects and numerical simulation of radiation damage in GaAs solar cells
Energy Technology Data Exchange (ETDEWEB)
A review of the deep-level defects observed in both electron- and proton-irradiated GaAs solar cells is presented. Studies of the effects of periodic and continuous thermal annealing on the radiation-induced electron and hole traps and the recombination parameters in GaAs solar cells were made for a wide range of electron and proton energies, fluence, annealing temperature and annealing time. A refined model for numerical simulations of the displacement damage was developed for computing the defect density and the cell parameters in the electron- and proton-irradiated GaAs solar cells. Excellent agreement was obtained between the calculated values and the experimental data for the proton-irradiated GaAs solar cells. (orig.).
1991-09-01
International Nuclear Information System (INIS)
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
1987-01-01
Electromagnetic interactions in the {Delta}-resonance region
Energy Technology Data Exchange (ETDEWEB)
Cross sections for some electro- and photoinduced spallation reactions on {sup 27}Al and {sup 51}V are measured in the energy region 130 MeV to 580 MeV with the activation method. Comparisons are made with calculations based on the Dalitz formalism for virtual photon spectra, and Monte Carlo calculations based on a cascade evaporation model, respectively. By use of Bremsstrahlung with end-point energies from threshold to 750 MeV, the yields for photo- production of{pi}{sup -}leading to ground and isomeric states in {sup 197}Hg are measured with the activation method. The activity from the Hg-isotopes were measured after a chemical separation of Hg from the target material. The yields and isomeric ratios are compared with impulse approximation calculations. For the photoproduction of {sup 195m}Hg and {sup 192}Hg from {sup 197}Au, the yields were measured. The experimental mean cross sections are compared with data from other ...
1995-03-01
International Nuclear Information System (INIS)
This report seeks to address the role of hydrogen bonding with Bronsted acids and bases in proton-coupled electron transfer (PCET) as it pertains to concerted or stepwise pathways of quinone (Q) and hydroquinone (QH_2) electrochemistry. This study was performed using a series of techniques that included cyclic voltammetry (CV), digital simulations, computational chemistry and "1H NMR. Hydrogen bonding was inferred by a decrease in diffusion coefficient (D) values measured using a pulsed gradient echo- (PGE-) "1H NMR technique. Changes of 40.8% and 37.9% in D values were only noted after the addition of two equivalents of acetate to 1,4-hydroquinone (1,4-QH_2) and catechol (1,2-QH_2), respectively. In contrast, the D values for the addition of selected amines (pyridine, N,N-diisopropylethylamine and triethylamine) changed only 3.2% on average. Quantum mechanical calculations were conducted to determine the pK_a of all quinoid species to serve as ...
2010-09-01
PET/MRI hybrid imaging: devices and initial results
British Library Electronic Table of Contents (United Kingdom)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
2008-01-01
Modeling of a self-excited pulse combustor and stability analysis
British Library Electronic Table of Contents (United Kingdom)
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
2011-01-01
Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam
TRANSVERSE EMITTANCE PRESERVATION IS A MAJOR CONCERN OF THE LHC INJECTOR CHAIN. MINIMISATION OF THE BLOW-UP DUE TO MISMATCH AT INJECTION INTO THE SPS IS THEREFORE MANDATORY. WHILE THE TRANSVERSE POSITIONN OF THE BEAM IN THE SPS INJECTION LINE IS MONITORED BUNCH BY BUNCH BY AN OTR (OPTICAL TRANSITION RADIATION) SCREEN AND A FAST CCD (CHARGED COUPLED DEVICE) CAMERA, THE PHASE SPACE MATCHING AT INJECTION IS MONITORED BY AN OTR BASED MISMATCH MONITOR IN THE SPS RING. ORTHOGONAL TUNING KNOBS WERE DEVELOPED TO TUNE INDEPENDENTLY TWISS PARAMETERS, DISPERSION AND DISPERSION DERIVATIVE. IN THIS PAPER WE DESCRIBE THE MISMATCH CORRECTION MECHANISM AS WELL AS THE TWO MONITORING SYSTEMS. WE REPORT ON FIRST MEASUREMENTS WHICH WERE CARRIED OUT DURING THE 1998 SPS RUN.
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this work was to combine asymmetric somatic hybridization (donor-recipient fusion or gamma fusion) to microprotoplast-mediated chromosome transfer, as a tool to be used for chromosome mapping in Citrus. Swinglea glutinosa micro protoplasts were irradiated either with 50, 70, 100 or 200 gamma rays and fused to cv. Ruby Red grapefruit or Murcott tangor protoplasts. Cell colonies were successfully formed and AFLP analyses confirmed presence of S. glutinosa in both 'Murcott' tangor and 'Ruby Red' grapefruit genomes. (author)
2009-12-15
Experimental Investigation of Solar Drying for Orange Peels by Forced convection
International Nuclear Information System (INIS)
Solar drier does not degrade any more the dried products with the manner of the products dried at the natural sun. The drying unit is composed mainly of a solar air collector and an enclosure of drying. The transformation of the solar radiation into heat is done thanks to the solar collector whose effectiveness is increased by the addition of suitable baffles in the mobile air vein. The efficiency of the collector reaches then 80. The hot air on the outlet side of the collector arrives in the enclosure of drying where the heat transfer with the product to be dried is done by convection. The kinetics drying study shows that in addition to the dependence of the temperature and air velocity of drying, the speed of drying also depends on fragmentation on the product to dry, and mainly, of the product surface in contact with the drying air. Thus, the hygrometry is reduced from 76 to 13 pour cent in one day.. The total efficiency of the drier reached ...
2009-01-30
Energy Technology Data Exchange (ETDEWEB)
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
1993-07-01
Considerations referring to chemical descaling of filmed carbon steels
International Nuclear Information System (INIS)
Under operational conditions in nuclear power plants, the carbon steel components of the primary and secondary circuits react with high temperature cooling agent forming several iron oxides and oxyhydroxides. These deposits can result in tubes' constrictions, pitting and intergranular corrosion and finally to heat transfer reducing and increasing of radiation fields around the circuits, as well. The descaling process involves the chemical dissolution of the corrosion deposits by means of diluted organic acidic solutions containing usually a carboxylic acid, a reductant and one or more corrosion inhibitors. To evaluate the removing rates of these superficial films two types of methods were used, the gravimetric and potentiodynamic techniques. By correlating the experimental results, we established the chemical composition of descaling solution and two models of mechanisms applicable to our specific conditions. (authors)
2009-10-12
British Library Electronic Table of Contents (United Kingdom)
SummaryThis paper examines the sensitivity and uncertainty of evaporation estimates from Nasser Lake, south of Egypt using data collected at the floating station Raft, 2km upstream of the Aswan High Dam, and 12 evaporation models. Based on their approach the evaporation models were ranked in five classes, respectively the Bowen ratio energy budget (BREB) approach, three energy-aerodynamic based methods, a mass transfer method, two temperature and five solar radiation-temperature approaches. State dependent parameter models were used to estimate the sensitivity indices of the different evaporation estimation methods at daily and monthly frequencies. A drastic reduction in the cost of the sensitivity analysis was obtained when coupled with efficient sampling methods, producing quasi-Monte Ca...
2010-01-01
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex ...
2007-08-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...
2011-01-01
Spectroscopy and photophysics of mono methyl-substituted alloxazines
Energy Technology Data Exchange (ETDEWEB)
Singlet-singlet and triplet-triplet absorption spectra of a series of methyl-alloxazines were calculated using the time-dependent density-functional theory approach and compared to experimental results. The B3LYP functional provides good correlation between experimental and theoretical results, given that solvent effects are disregarded in the present calculations. Substituent and solvent dependences of the lowest, closely spaced, n,{pi}* and {pi},{pi}* excited state energies are discussed, their order being of consequence in determining the non-radiative decay rates and thus emission quantum yields and lifetimes. The high quantum yields of singlet oxygen formation indicate that the triplet state is formed by efficient intersystem crossing from the first singlet excited state.
2004-05-31
Microwave transport in EBT distribution manifolds using Monte Carlo ray-tracing techniques
Energy Technology Data Exchange (ETDEWEB)
Ray tracing Monte Carlo calculations have been carried out using an existing Monte Carlo radiation transport code to obtain estimates of the microsave power exiting the torus coupling links in EPT microwave manifolds. The microwave power loss and polarization at surface reflections were accounted for by treating the microwaves as plane waves reflecting off plane surfaces. Agreement on the order of 10% was obtained between the measured and calculated output power distribution for an existing EBT-S toroidal manifold. A cost effective iterative procedure utilizing the Monte Carlo history data was implemented to predict design changes which could produce increased manifold efficiency and improved output power uniformity.
1983-01-01
Metastable one- and two-electron donor states in GaAs and CdF{sub 2}
Energy Technology Data Exchange (ETDEWEB)
The strongly localized one-electron (D{sup 0}) and two-electron (D{sup -}) donor states are considered with the lattice deformation around the donor center taken into account. For GaAs, donor energy levels have been calculated as functions of the hydrostatic pressure. The calculated energy positions and pressure coefficients agree with the experimental data. It is shown that the interaction with phonons reduces the probability of radiative transitions between the states of different localization and leads to the metastability of shallow-level donor states with respect to the D{sup -} state in GaAs and both the states (D{sup 0} and D{sup -}) in CdF{sub 2}. (author) 7 refs, 1 fig
1996-12-31
Electronic structure, Compton profiles and optical properties of TaC and TaN
International Nuclear Information System (INIS)
Isotropic Compton profiles of TaC and TaN have been measured for the first time, at an intermediate resolution, using 662 keV #gamma#-radiation. Energy bands, density of states and Fermi surface topology of TaC and TaN have been computed using linear combination of atomic orbitals with density functional theory and full potential linearised augmented plane wave method. Both band structure calculations predict the metallic character of TaC and TaN. The electron momentum densities calculated using various approaches of density functional theory are compared with the present measurements. On the basis of Mulliken's population, it is also seen that TaC has more covalent bonding than TaN. The optical properties computed using full potential linearised augmented plane wave method are explained in terms of intraband transitions.
2010-11-01
Alpha-particle dose distribution effects at the cellular level
International Nuclear Information System (INIS)
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
1985-02-01
Energy Technology Data Exchange (ETDEWEB)
A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...
1999-07-01
Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System
Energy Technology Data Exchange (ETDEWEB)
RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery ...
1998-01-16
Production of rare earth enriched isotopes and americium 242 using metallphthalocyanines
International Nuclear Information System (INIS)
A technique of producing radioactive isotopes of rare earth elements (r.e.e.) and carrier free "2"4"2Am is suggested. The technique makes use of ''sandwich'' phthalocya=- nine complexes of r.e.e. and americium placed on sorbent. This is a new type of r.e.e. compounds and actinides (C_3_2H_1_6N_8)_2M (M is a metal ion) which are thermally, radiationally and chemically stable, dissolve well in some organic solvents and do not dissolve in water. Radiation and chemically stable activated carbon is used as a sorbent carrier. After irradiation the target is treated by a weakly acid solution or complex-former solution. Radioactive atoms formed due to (n, #gamma#)-reaction and desoleting the complex because of recoil transfer into the solution. When irradiating in the flux of 10"1"3 neutr./cm"2 x s for 1 hour it is possible to produce radioactive isotopes with the yield from 20 to 90%, for example "1"6"0Tb, "1"6"6Ho with enrichment ...
Numerical simulations of industrial processes involving fluid dynamics, combustion and radiation
Energy Technology Data Exchange (ETDEWEB)
Moving out of the scientific community research laboratories, computational fluid dynamics (CFD) software packages are now allowing industrials to analyse and optimize industrial processes involving the use of gases, liquids and even some two-phase fluids. Their attractiveness and their impact stems out from the opportunity they offer to bring insight into an existing unit, or even at the design stage, by displaying the spatial distribution of process relevant variables such as temperature, concentration. The filling of the spacing in between a two-layer window is a simple example. This new opportunity of visualisation is at times an unique way, when the process environment is an opaque one, such as liquid metal flowing into a tundish or when measurements of flows may be a long and tedious work, such as flows within water treatment basins. This environment we are to investigate in order to optimize can also be a harsh one, due to its high temperature level for example. Such are ...
1997-12-31
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
Energy Technology Data Exchange (ETDEWEB)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
1990-10-01
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
International Nuclear Information System (INIS)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
International Nuclear Information System (INIS)
The near-yrast states of "1"0"1_4_2Mo_5_9 and "1"0"3","4_4_4 Ru_5_9_,_6_0 have been studied following their population via heavy-ion multinucleon transfer reactions between a "1"3"6Xe beam and a thin, self-supporting "1"0"0Mo target. The ground state sequence in "1"0"4Ru can be understood as demonstrating a simple evolution from a quasi-vibrational structure at lower spins to statically deformed, quasi-rotational excitation involving the population of a pair of low-#OMEGA# h_1_1_/_2 neutron orbitals. The effect of the decoupled h_1_1_/_2 orbital on this vibration-to-rotational evolution is demonstrated by an extension of the ''E-GOS'' prescription to include odd-A nuclei. The experimental results are also compared with self-consistent Total Routhian Surface calculations which also highlight the polarising role of the highly aligned neutron h_1_1_/_2 orbital in these nuclei. (author)
2005-04-01
Kbeta-to-Kalpha X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of Ti(x)Ni(1-x) (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi (109)Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured Kbeta-to-Kalpha X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of ...
2010-01-28
International Nuclear Information System (INIS)
K?-to-K? X-ray intensity ratios of Ti and Ni have been measured in pure metals and in alloys of TixNi1-x (x=0.7, 0.6, 0.5, 0.4 and 0.3) following excitation by 22.69 keV X-rays from a 10 mCi 109Cd radioactive point source. The valence-electron configurations of these metals were determined by corporation of measured K?-to-K? X-ray intensity ratios with the results of multiconfiguration Dirac-Fock calculation for various valence-electron configurations. Valence-electron configurations of 3d-transition metals in alloys indicate significant differences with respect to the pure metals. Our analysis indicates that these differences arise from delocalization and/or charge transfer phenomena in alloys. Namely, the observed change of the valence-electron configurations of metals in alloys can be explained with the transfer of 3d electrons from one element to the other element and/or the rearrangement of electrons between 3d and 4s, ...
2010-06-01
International Nuclear Information System (INIS)
Experimental and theoretical work have been carried out to find out the effects of heat transfer augmentation on two-phase flow instabilities in a single channel system. The effect of mass flow rate, heat input and inlet subcooling on the system behavior is studied using Freon-11 as the test fluid and six different heater surfaces are tested at various experimental conditions. Experimental evaluation is done using the steady-state pressure drop versus mass flow rate curves along with the curves of additional inlet pressure drop required to stabilize the system during the oscillations, and tables generated using the experimental data. Homogeneous equilibrium flow model and finite differences are used in theoretical analysis. An empirical relationship is obtained to calculate the pressure drop across the exit restriction. Characteristic equation for the system is found by linearizing the dynamic equations of the overall system and analyzed to ...
1985-11-01
Potential biogas scrubbing using a high rate pond
Energy Technology Data Exchange (ETDEWEB)
The potential to scrub biogas in a high rate pond (HRP) was evaluated using apparatus designed to maximize gas-liquid contact. Experiments compared the removal of carbon dioxide from synthetic biogas by an 'in-pond angled gutter' to that by a simulated 'counter-current pit'. Results showed that the counter current pit has potential for use in biogas scrubbing, with synthetic biogas carbon dioxide composition consistently reduced from 40% to<5%. The in-pond angled gutter was less effective due to bubble coalescence which reduced the total bubble surface surface area available for gas transfer. Measurement of oxygen levels in the scrubbed biogas showed that despite supersaturation of oxygen in the HRP water, there was little transfer to the biogas, so that explosive methane/oxygen mixtures would not be formed. Theoretical calculations indicated that the amount of biogas likely to be ...
2005-07-01
Low temperature humidification dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water temperature. Also, the water production is found to ...
2006-03-01
Low temperature humidification dehumidification desalination process
International Nuclear Information System (INIS)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water temperature. Also, the water production is found to ...
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
Substantial thermal performance improvement in ice-on-tube cold thermal energy storage systems (TES) is possible by making use of porous copper mesh as a Heat Conducting Enhancement Device (HCED). HCEDs are inexpensive heat transfer augmentation devices that can result in faster rate of ice growth and larger final steady state ice build volume by reducing the controlling thermal conduction resistance of the ice layer. This improves the competitiveness of external ice-on-tube systems as compared to other TES systems, such as dynamic ice harvesters and static internal melt systems. In this study the amount of ice growth enhancement is predicted theoretically, by performing simplified 1-D calculations, and is then validated in the laboratory through carefully controlled experiments. This study shows that ice volume increase between 50 and 90% is possible by using HCEDs of the type tested. (author)
2006-09-15
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...
1981-05-01
International Nuclear Information System (INIS)
Tris(8-quinolinolato)aluminum(III) (Alq3) shows electronic absorption bands at 378, 360 (in a 1:1 mixed solvent of methanol and ethanol (ME) at 77 K), 334, 316, 300, 263, 255.8, and 233 nm in ethanol at room temperature. According to the polarized fluorescence excitation spectrum together with MO calculations, for instance, the 360 nm band is assigned to an LL CT transition (an intramolecular charge transfer transition between two ligands), and the 378 nm band to an LM/ML CT one (an intramolecular charge transfer transition between ligand and metal). Alq3 shows a broad fluorescence band peaking at around 478 nm in the ME matrix at 77 K. The emission spectrum measured with a phosphoroscope has two emission bands at 567 and 478 nm. The 567 nm band accompanies vibronic bands at 578 and 605 nm, being safely assigned to a phosphorescence of Alq3. The lifetimes of the 478 and 567 nm bands are both 5.4 ms. The lifetime of the 478 ...
2008-08-01
Effect of vasopressin on ependymal and capillary permeability to tritiated water in cat
Energy Technology Data Exchange (ETDEWEB)
Ependymal cells line the cerebral ventricles forming the interface that separates the cerebrospinal (CSF) and interstitial fluids (ISF). Extracellular molecules move between ependymal cells, whereas lipid soluble molecules pass both between and through cells. We measured the transfer of tritiated water (TOH) from CSF to blood across the ependymal and capillary interfaces by ventriculocisternal (VC) steady-state tissue clearance. Adult cats anesthetized with pentobarbital sodium underwent VC perfusion with the extracellular marker (/sup 14/C)sucrose and TOH added to the artificial CSF. Brain tissue was analyzed for depth of penetration of the isotopes into periventricular gray matter. We found that TOH distribution space was lower than expected from water content measurements, whereas sucrose space was normal. Using VC steady-state equations we calculated an ependymal permeability that was similar to the permeability of the cerebral capillary. ...
1986-09-01
Coriolis effect on thermal convection in a couple-stress fluid-saturated rotating rigid porous layer
Energy Technology Data Exchange (ETDEWEB)
Both linear and weakly nonlinear stability analyses are performed to study thermal convection in a rotating couple-stress fluid-saturated rigid porous layer. In the case of linear stability analysis, conditions for the occurrence of possible bifurcations are obtained. It is shown that Hopf bifurcation is possible due to Coriolis force, and it occurs at a lower value of the Rayleigh number at which the simple bifurcation occurs. In contrast to the nonrotating case, it is found that the couple-stress parameter plays a dual role in deciding the stability characteristics of the system, depending on the strength of rotation. Nonlinear stability analysis is carried out by constructing a set of coupled nonlinear ordinary differential equations using truncated representation of Fourier series. Sub-critical finite amplitude steady motions occur depending on the choice of physical parameters but at higher rotation rates oscillatory convection is found to be the preferred mode of instability. ...
2011-04-15
Energy Technology Data Exchange (ETDEWEB)
Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient for use with test pipes of unknown emittances. Measurements ...
1981-10-01
The natural background approach to setting radiation standards
International Nuclear Information System (INIS)
The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent ...
1979-03-09
International Nuclear Information System (INIS)
Although low-energy ion radiation has been proven to have a wide range of biological effects and led to fruitful achievements as a new mutagenic source for genetic modification, there still exist some disputes about its mutagenic mechanisms because of its short-penetrating property. In present research, Arabidopsis thaliana transgenic for GUS recombination substrate was used to evaluate the genomic instability induced by irradiations of alpha particle (3.3MeV) and Low-energy-Argon ion (30 KeV). A pronounced effects of alpha particle irradiation to Arabidopsis thaliana seedlings and Argon ion irradiation to seeds on the somatic homologous recombination frequency (sHRF) were reported. The sHRFs increased 1.88-fold and 2.42-fold, respectively, which indicated that the short-penetrating radiation could effectively induce the plant genomic instability in either dry seeds or seedlings with active metabolism. The local alpha particle irradiation of ...
2008-08-12
Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill
Energy Technology Data Exchange (ETDEWEB)
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in ...
1997-06-01
Radiation inactivation target size of rat adipocyte glucose transporter
Energy Technology Data Exchange (ETDEWEB)
In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due to an interaction with a ...
1987-05-01
Aerosol-induced changes of convective cloud anvils produce strong climate warming
The effect of aerosol on clouds poses one of the largest uncertainties in estimating the anthropogenic contribution to climate change. Small human-induced perturbations to cloud characteristics via aerosol pathways can create a change in the top-of-atmosphere radiative forcing of hundreds of Wm-2. Here we focus on links between aerosol and deep convective clouds of the Atlantic and Pacific Intertropical Convergence Zones, noting that the aerosol environment in each region is entirely different. The tops of these vertically developed clouds consisting of mostly ice can reach high levels of the atmosphere, overshooting the lower stratosphere and reaching altitudes greater than 16 km. We show a link between aerosol, clouds and the free atmosphere wind profile that can change the magnitude and sign of the overall climate radiative forcing. We find that increased aerosol loading is associated with taller cloud towers and anvils. The taller clouds ...
2010-05-01
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. ...
1988-10-01
Complete electroweak matching for radiative B decays
We compute the complete two-loop O(alpha) Wilson coefficients relevant for radiative decays of the B meson in the SM. This is a necessary step in the calculation of the O(alpha alpha_s^n ln^n m_b/M_W) corrections and improves on our previous analysis of electroweak effects in B -> X_s gamma. We describe in detail several interesting technical aspects of the calculation and include all dominant QED matrix elements. In our final result, we neglect only terms originated from the unknown O(alpha alpha_s) evolution of the Wilson coefficients and some suppressed two-loop matrix elements. Due to the compensation among different effects, we find that non-trivial electroweak corrections decrease the branching ratio by about 3.8% for a light Higgs boson, in agreement with our previous analysis. As in [1], the corresponding SM prediction for the branching ratio with E_gamma > 1.6 GeV is (3.60 +- 0.30) x 10^-4.
2001-01-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of ...
2010-10-01
International Nuclear Information System (INIS)
Lappeenranta University of Technology (LTKK) and VTT Energy carried out a series of preliminary tests in 1999 to study the behavior of noncondensable (NC) gases in VVER geometry. The tests aimed at studying the effect of NC gases on system thermal-hydraulics and on heat transfer in a horizontal steam generator (HSG). The system behavior can be affected by hydrogen produced in the core in case of a severe accident, by nitrogen from hydro-accumulators released into the primary circuit in case of a loss-of-coolant accident (LOCA) and more generally by any NC gas in all cases where cooling is ensured by natural circulation. A secondary objective of the tests - the first series of tests ever performed with NC gas with PACTEL - was to find out, if the instrumentation of PACTEL was adequate for this type of tests and if it was functioning properly. This paper presents the measured and calculated (CATHARE code version V15a mod 2.1) results of the test ...
2001-03-20
Energy Technology Data Exchange (ETDEWEB)
MAGMA is a FORTRAN computer code designed to viscous flow in in situ vitrification melt pools. It models three-dimensional, incompressible, viscous flow and heat transfer. The momentum equation is coupled to the temperature field through the buoyancy force terms arising from the Boussinesq approximation. All fluid properties, except density, are assumed variable. Density is assumed constant except in the buoyancy force terms in the momentum equation. A simple melting model based on the enthalpy method allows the study of the melt front progression and latent heat effects. An indirect addressing scheme used in the numerical solution of the momentum equation voids unnecessary calculations in cells devoid of liquid. Two-dimensional calculations can be performed using either rectangular or cylindrical coordinates, while three-dimensional calculations use rectangular coordinates. All derivatives are ...
1991-11-01
Simulation of sludge deposit onto a 900 MW steam generator tubesheet with the 3D code GENEPI
Energy Technology Data Exchange (ETDEWEB)
Heat transfer processes use fluids which are generally not pure and can react with transfer surfaces. These surfaces are subject to deposits which can be sediments harmful to heat transfer and to integrity of materials. For nuclear plant steam generators, sludge build-up accelerates secondary side corrosion by concentrating chemical species. A major safety problem involved with such a corrosion is the growing of circumferential cracks which are very difficult to detect and size with eddy current probes. With a view to understand and control this problem, it is necessary to develop a mathematical model for the prediction of sludge behavior in PWR steam generators. Based on fundamental principles, this work intends to use different models available in literature for the prediction of the phenomenon leading to the accumulation of sludge particles at the bottom (the tubesheet) of a PWR. For that, a three-dimensional simulation ...
1998-07-01
Conjugate Heat Transfer Predictions of a Combustor ...
... To maximise heat transfer rates, many heatshield designs make use of heat transfer augmentation devices such as large numbers of pin-fin ...
2003-03-01
Augmentation of heat and mass transfer
Energy Technology Data Exchange (ETDEWEB)
This is the first text and reference book to be devoted completely to the very important and timely subject of heat transfer augmentation. This book is of equal appeal to both researchers and designers of heat transfer equipment.
1986-01-01
The application of Geant4 simulation code for brachytherapy treatment
Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.
2000-01-01
The High-Redshift Neutral Hydrogen Signature of an Anisotropic Matter Power Spectrum
An anisotropic power spectrum will have a clear signature in the 21cm radiation from high- redshift hydrogen. We calculate the expected power spectrum of the intensity fluctuations in neutral hydrogen from before the epoch of reionization, and predict the accuracy to which future experiments could constrain a quadrupole anisotropy in the power spectrum. We find that the Square Kilometer Array will have marginal detection abilities for this signal at z~17 if the process of reionization has not yet started; reionization could enhance the detectability substantially. Pushing to higher redshifts and higher sensitivity will allow highly precise (percent level) measurements of anisotropy.
2011-01-01
Review of electron beam therapy physics
Energy Technology Data Exchange (ETDEWEB)
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
2006-07-07
Radiotherapeutic methods for Ewing's sarcoma of the long tubular bones in children
International Nuclear Information System (INIS)
Radiotherapeutic results of the Ewing sarcoma of the long tubular bones in 140 pediatric patients aged 3-16 are analyzed with the respect to different methods of irradiation. Three-field irradiation, the fields being located at 120 deg to one another with daily irradiation of all three fields at a focal dose of 2 Gy, was found superior in treatment of primary neoplasm. It is stressed that the disease termination mainly depends on the efficiency of primary neoplasm treatment, as the neoplasm reccurence generally is followed by metastases. Radiation load is calculated for maximal irradiation area of soft tissues in children.
Production of secondary Deuterium in the atmosphere at various latitudes
Energy Technology Data Exchange (ETDEWEB)
Secondary deuterium in the atmosphere are produced in interactions by primary cosmic rays. The shape of their energy spectrum depends on the primary cosmic ray spectrum incident at the top of the atmosphere. At high energies, the spectral shape depends on the primary spectrum of helium and heavy nuclei. However, at very low energies, specially below the geomagnetic cut-off, the spectral shape depends on the evaporation and recoil processes and hence almost independent of the spectral shape of the primary radiation. It is undertaken a calculation of the secondary deuterium spectrum at small atmospheric depths at various latitudes and the results will be presented.
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.
2007-03-01
International Nuclear Information System (INIS)
Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.
2007-03-01
Neutron cross section measurements using the Oak Ridge electron linear accelerator
Energy Technology Data Exchange (ETDEWEB)
During this reporting period, the work supported under DOE Grant No. FG02-87ER40326.A003 has resulted in one publication, two papers submitted to Phys. Rev. C for publication, and one paper presented at a professional meeting. During this period, modifications were made to the interactive R-Matrix fitting computer program DSIG to include the total radiation widths in the R-Matrix calculation of the cross section. The R-Matrix analyses of n+{sup 90}Zr and n+{sup 208}Pn have already begun.
1990-08-01
Neutrinos produced by nuclei injected by young pulsars inside compact massive binaries
Energy Technology Data Exchange (ETDEWEB)
We consider propagation of relativistic heavy nuclei injected by a young pulsar into the radiation field of a massive companion. If the binary system (BS) is compact enough, then the nuclei suffer multiple photodisintegrations in collisions with thermal photons coming from the massive star (MS). Due to the propagation effects of charged particles in the magnetic field of the MS some hadrons can impinge onto the MS surface at large angles. We calculate the fluxes of produced neutrinos as a function of the viewing angle measured from the plane of the BS. It is found that significant fluxes of neutrinos should be also expected in the case of non-eclipsing BSs.
2005-06-15
Mira variables - Pulsation, mass loss and evolution
International Nuclear Information System (INIS)
Recent developments in the analysis of Mira atmosphere, the determination of the pulsation mode, the problem of mass loss, and the evolution of the Mira variables are covered. Model atmospheres for Mira variables, including the opacities of the molecules expected in very late M-type atmospheres are discussed. The pulsation constant for Omicron Ceti is evaluated using T(eff) = 2900 + or - 200 K, and it is concluded that Miras are fundamental mode pulsators. The importance of molecular opacity to the driving of mass loss is evaluated, and it is pointed out that the radiation pressure on molecules is not a major factor in driving mass loss from Mira. Mass loss is considered as a factor in the calculations of the periods for Mira variables. 30 refs.
1990-05-28
International Nuclear Information System (INIS)
With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).
1985-10-22
FFTF shield and gamma ray measurements
Energy Technology Data Exchange (ETDEWEB)
Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.
1984-08-01
Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor
Energy Technology Data Exchange (ETDEWEB)
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
1996-12-31
Billion particle linac simulations for future light sources
Energy Technology Data Exchange (ETDEWEB)
In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.
2008-09-25
A new type active personal dosemeter with a solid state detector
International Nuclear Information System (INIS)
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
1988-04-01
Accumulation and excretion of metabolized "1"0"6Ru in prawn meat ingested by mice
International Nuclear Information System (INIS)
This paper aims at the study of the transfer and accumulation of "1"0"6Ru from marine foods to man through the grazing food chain and evaluation of the radiation exposure to man. As a model, accumulation and excretion of "1"0"6Ru in mice orally administered by the meat of prawn (Penaeus japonicus) which accumulated the radionuclide from the sea water, were examined and compared with those in mice administered by non-radioactive prawn meat mixed with the contaminant in inorganic chemical forms (the control diet); on the latter experiment, the previous evaluation method of the radiation exposure was based. Higher concentrations of "1"0"6Ru in tissues and organs of mice were observed in the former diet than in the latter because of the higher absorption rate of "1"0"6Ru from the gastrointestinal tract (17.4 +- 4.4%, the control diet: 0.7 +- 0.7%) and smaller excretion. As the results of this experiment, the critical organs for ...
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...
1996-12-01
Impact of radiation measurements on hardening of TFTR diagnostics
International Nuclear Information System (INIS)
Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both inside and outside the ...
Energy Technology Data Exchange (ETDEWEB)
The O({alpha}) electroweak radiative corrections to {gamma}{gamma}{yields}WW{yields}4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for {gamma}{gamma}{yields}4f+{gamma}. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer {gamma}{gamma} - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over realistic spectra of ...
2005-09-01
International Nuclear Information System (INIS)
The O(#alpha#) electroweak radiative corrections to #gamma##gamma##->#WW#->#4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for #gamma##gamma##->#4f+#gamma#. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer #gamma##gamma# - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over realistic spectra of the ...
2005-09-01
Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki
International Nuclear Information System (INIS)
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic distribution for the survivors incide a ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport might be reduced. ...
2004-02-01
The questions of liquid metal two-phase flow modelling in the FBR core channels
International Nuclear Information System (INIS)
The two-fluid model representation for calculations of two-phase flow characteristics in the FBR fuel pin bundles with liquid metal cooling is presented and analysed. Two conservation equations systems of the mass, momentum and energy have been written for each phase. Components accounted the mass-, momentum- and heat transfer throughout the interface occur in the macro-field equations after the averaging procedure realisation. The pattern map and correlations for two-fluid model in vertical liquid metal flows are presented. The description of processes interphase mass- and heat exchange and interphase friction is determined by the two-phase flow regime. The opportunity of the liquid metal two-phase flow regime definition is analysed. (author)
2000-06-01
British Library Electronic Table of Contents (United Kingdom)
A novel difunctional acylhydrazone has been synthesized by the reaction of 5-methylisoxazole-4-carboyl hydrazine with benzaldehyde and characterized by X-ray crystallography and spectroscopy. The obtained results demonstrate the crystal belongs to triclinic, space group Formula Not Shown . Moreover, the spectroscopic properties were evaluated through density functional theory (DFT) and time-dependent density functional theory (TD DFT) calculations. The results reveal that UV-Vis absorption peaks at 194, 217.5 and 290.5nm are mainly attributed to (p, p)p*, partly (p, p)p* and partly pp*, and predominantly pp*, respectively, with intraligand charge-transfer transition (ILCT) character. The fluorescence emission peak at 485.96nm should be assigned to ILCT. In addition, the results of antibact...
2011-01-01
Spectroscopy of neutron-rich {sup 59-63}Mn isotopes
The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a {sup 238}U target with a beam of {sup 70}Zn at an energy of E{sub lab}=460 MeV. Prompt {gamma} rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.
2008-08-15
Spectroscopy of neutron-rich "5"9"-"6"3Mn isotopes
International Nuclear Information System (INIS)
The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a "2"3"8U target with a beam of "7"0Zn at an energy of E_l_a_b=460 MeV. Prompt #gamma# rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.
2008-08-01
Semihard production of neutral pseudoscalar and tensor mesons in photon-photon collisions
Energy Technology Data Exchange (ETDEWEB)
We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).
1992-12-21
Oak Ridge Research Reactor. Quarterly report, July, August, and September 1984
Energy Technology Data Exchange (ETDEWEB)
The ORR operated at an average power level of 29.7 MW for 85.3% of the time during this period. The reactor was shut down on fifteen occasions, nine of which were unscheduled. Reactor downtime needed for refueling and checks was normal. The reactor remained available for operation 88.3% of the time. Special tests completed during the quarter included: (1) transfer of LEU fuel elements CLE-202 and NLE-201 from core positions B-9 and B-2 to core positions C-5 and C-6 for continued operation; and (2) calculation of maximum heat flux in LEU elements CLE-201 and NLE-202 in core positions A-2 and A-8. In-service inspections included inspections of ORR decay tank, primary heat exchanger No. 4, and the 24-in. strainer.
1985-03-01
Mixed convection in a rectangular channel (width/height = 2) with bottom-heated and top-cooled sections is studied by laser Doppler anemometry in nitrogen at Ra = 22,200 and Re = 18.75, 36, and 54. At the lower Re values, symmetry breaking is observed in steady but spatially oscillating flows that prevail over a certain distance from the leading edge of the differentially heated section. Further downstream, unsteady flows are found even for Re = 18.75. Numerical models are used to investigate the effects of adiabatic, conducting (with a conductive-convective heat transfer coefficient), and perfectly conducting side walls; channel tilts and Prandtl number dependence. Good agreement between calculations and experiment is obtained for longitudinal convective roll velocities. The transverse velocities are found to be independent of Re.
1992-06-01
Large-Scale Simulation of Beam Dynamics in High Intensity Ion Linacs Using Parallel Supercomputers
In this paper we present results of using parallel supercomputers to simulate beam dynamics in next-generation high intensity ion linacs. Our approach uses a three-dimensional space charge calculation with six types of boundary conditions. The simulations use a hybrid approach involving transfer maps to treat externally applied fields (including rf cavities) and parallel particle-in-cell techniques to treat the space-charge fields. The large-scale simulation results presented here represent a three order of magnitude improvement in simulation capability, in terms of problem size and speed of execution, compared with typical two-dimensional serial simulations. Specific examples will be presented, including simulation of the spallation neutron source (SNS) linac and the Low Energy Demonstrator Accelerator (LEDA) beam halo experiment.
2000-01-01
International Lens Design Conference, Monterey, CA, June 11-14, 1990, Proceedings
Energy Technology Data Exchange (ETDEWEB)
The present conference on lens design encompasses physical and geometrical optics, diffractive optics, the optimization of optical design, software packages, ray tracing, the use of artificial intelligence, the achromatization of materials, zoom optics, microoptics and GRIN lenses, and IR lens design. Specific issues addressed include diffraction-performance calculations in lens design, the optimization of the optical transfer function, a rank-down method for automatic lens design, applications of quadric surfaces, the correction of aberrations by using HOEs in UV and visible imaging systems, and an all-refractive telescope for intersatellite communications. Also addressed are automation techniques for optics manufacturing, all-reflective phased-array imaging telescopes, the thermal aberration analysis of a Nd:YAG laser, the analysis of illumination systems, athermalized FLIR optics, and the design of array systems using shared symmetry.
1990-01-01
Fermion-fermion and boson-boson amplitudes: surprising similarities
Amplitudes for fermion-fermion, boson-boson and fermion-boson interactions are calculated in the second order of perturbation theory in the Lobachevsky space. An essential ingredient of the model is the Weinberg's 2(2j+1)-component formalism for describing a particle of spin j. The boson-boson amplitude is then compared with the two-fermion amplitude obtained long ago by Skachkov on the basis of the Hamiltonian formulation of quantum field theory on the mass hyperboloid, p_0^2 - p^2=M^2, proposed by Kadyshevsky. The parametrization of the amplitudes by means of the momentum transfer in the Lobachevsky space leads to same spin structures in the expressions of T-matrices for the fermion case and the boson case. However, certain differences are found. Possible physical applications are discussed.
2007-01-01
Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K
International Nuclear Information System (INIS)
The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.
1991-01-01
Electrochromic effects of charge separation in bacterial photosynthesis: theoretical models
Energy Technology Data Exchange (ETDEWEB)
The primary charge separation in photosynthetic bacteria generates a dimeric bacteriochlorophyll (BChl) cation and a bacteriopheophytin (BPheo) anion which lie within close proximity of each other (approx. 10 A). The two radicals also lie within van der Waals contact on opposite sides of a lone BChl bridging molecule. Spectral changes in the red (Q/sub y/) band of the bridge BChls have been observed on picosecond time scales following excitation of the reaction center (RC) and have been variously attributed to the formation of a BChl anion, to a charge-transfer state, or to electrochromic effects. They present calculations here which suggest that electrochromic effects caused by the photogenerated cation and/or anion can rationalize the optical changes observed in the flash photolyses as well as in trapping experiments.
1987-07-22
Effects of velocity-dependent force on the magnetic form factors of odd-Z
International Nuclear Information System (INIS)
We investigate the effects of the velocity-dependent force on the magnetic form factors and magnetic moments of odd-Z nuclei. The form factors are calculated with the harmonic-oscillator wavefunctions. It is found that the contributions of the velocity-dependent force manifest themselves in the very large momentum transfer region (q?4 fm-1). In the low and medium q region the contributions of the velocity-dependent force are very small compared with those without this force. However, in the high-q region the contributions of the velocity-dependent force are larger than the normal form factors. The diffraction structures beyond the existing experimental data are found after the contributions of the velocity-dependent force are included. The formula of the correction to the single particle magnetic moment due to the velocity-dependent force is reproduced exactly in the long-wavelength limit (q=0) of the M1 form factor. (authors)
2008-03-01
Energy Technology Data Exchange (ETDEWEB)
Examination is made of the main features of the physical and chemical preignition processes within homogeneous mixtures of air and gaseous fuels, such as propane, methane and hydrogen in a motored engine, while employing detailed chemical kinetics in a one zone analytical model. The changes in the compression temperature and pressure due to the admission of gaseous fuels, energy release during the preingition reactions and the contributions of heat transfer and residual gases to the preignition reaction activity were followed over a number of consecutive cycles until the occurrence of autoignition. Some of the observed differences in engine behaviour when operating on methane, propane and hydrogen were discussed with particular reference to the observed trends in dual fuel engine operation. Calculated results showed good agreement with some corresponding experimental trends. 14 refs., 9 figs.
1994-10-01
A method of stereotaxic localization adopted for conventional and digital radiography
International Nuclear Information System (INIS)
A method for the determination of stereotaxic coordinates in radiography, e.g. angiography, pneumoencephalography or digital vascular radiography, is described. A special localization frame containing radiopaque structures and scales defines a diagnostic coordinate system. This frame is fixed to the X-ray-table prior to the radiographic procedure and two projections are obtained at arbitrary angles to each other. The focus-film distances do not have to be fixed. The target coordinates are then determined either by a simple graphical procedure or with the use of a digitizing x-y-table, by a computer. With the computer method the films are placed on the digitizing table and the target and a few reference points are marked using a cursor. From the relative positions the computer calculates the coordinates. With the special head fixation system, coordinates of structures visualized in radiographic examinations can be transferred to various ...
1986-01-01
International Nuclear Information System (INIS)
The commercial Modular High Temperature Gas-Cooled Reactor (MHTGR) achieves improved reactor safety performance and reliability by utilizing an integrated sequence of completely passive thermal storage and heat transfer mechanisms to reject decay heat in the event that all its active cooling systems fail to operate. During such events, the initial heatup transient in the core is followed by a quasi-steady state cooldown process which, if uninterrupted, can continue for several days. A buoyancy-driven natural convection cooling system called the RCCS facilitates the continuous heat removal by circulating ambient air through the reactor cavity, where it is heated and then exhausted to the outside environment. The peak thermal load on the RCCS occurs approximately at the time that the vessel reaches its highest temperature. To confirm the adequacy of the RCCS design, detailed analytical models were developed to simulate the decay heat removal process and predict the ...
1994-08-01
International Nuclear Information System (INIS)
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its ...
2001-03-01
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
International Nuclear Information System (INIS)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the interinstitutional ...
2007-06-01
ASME proceedings of the 31. national heat transfer conference: Volume 2. HTD-Volume 324
Energy Technology Data Exchange (ETDEWEB)
This volume is divided into the following sections: (1) fundamentals of convection heat transfer; (2) fundamentals of heat transfer with impinging jets; and (3) fundamentals of heat transfer augmentation. Separate abstracts were prepared for most papers in this volume.
1996-12-31
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
International Nuclear Information System (INIS)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. ...
2011-01-01
International Nuclear Information System (INIS)
In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive waste water and low temperature cooling ...
Shape isomers: Mean-field description and beyond
Energy Technology Data Exchange (ETDEWEB)
Nuclear Hartree-Fock (HF) + BCS calculations have led to predictions of shape isomerism in isotopes of Pt, Hg and Os nuclei. These have been confirmed through the observation of superdeformed rotational bands in {sup 190,{hor ellipsis},194}Hg. Encouraged by these measurements and similar observations in {sup 194}Pb, we have extended these calculations to a wide range of contiguous nuclei. These HF results, for {sup 192,194}Pt, {sup 190,{hor ellipsis},198}Hg and {sup 194}Pb, have been employed in a Generator Coordinate Method (GCM) calculation utilizing the quadrupole deformation as the generating variable. The resulting spectra confirm the conclusions drawn from the HF results and agree with those experiments which have been performed. Adding a phenomenological assumption for the moments of inertia of our GCM states, we can construct the radiative transitions within and out of the superdeformed band. ...
1990-11-19
Energy Technology Data Exchange (ETDEWEB)
The present study treats only the collective risk of ex-utero leukaemia associated with the routine releases of the nuclear industrial installations of the North Cotentin (0.0009 cases over the considered period) the uncertainty on the contribution to the collective risk of the incidents and the accidents of the nuclear installations (notably the drilling of the pipe of release in sea arisen in 1979-1980 and the fire of the waste silo on January 6. 1981, for the reprocessing plant of La Hague has not been considered. Only 45% of the risk are taken into account by the study. Every calculated value remains very inferior to the number of leukemia cases observed (4 cases observed for two expected cases) and to the risk of radioinduced leukemia any merged exposure sources, that is to say 0.84 cases. It appears thus not very probable that the nuclear installations of the North - Cotentin can explain the tendency to the excess of observed leukaemia. The limits of the ...
2003-03-15
Correlations for the yearly or seasonally optimum salt-gradient solar pond in Greece
Energy Technology Data Exchange (ETDEWEB)
Simple correlations and corresponding nomographs are presented, which express the maximum useful heat received from salt-gradient solar ponds throughout the year or during a specified season of the year, and the corresponding optimum depth of the nonconvective zone in terms of the thickness of the upper convective zone and the temperature under which the maximum useful heat is received. The correlations are valid for the Athens (Greece) area or for regions with a similar climate, because solar radiation and ambient temperature values for Athens have been employed, obtained by a statistical process of hourly measurements over a period of about 20 years. For other climates, it is easy to develop similar correlations using the same methodology, Development of the proposed correlations is based on a method, which simulates the transient operation of the salt-gradient pond using finite-differences, and calculates the useful heat received hourly ...
1993-05-01
Calculations of long-lived isomer production in neutron reactions
Energy Technology Data Exchange (ETDEWEB)
We have carried out theoretical calculations for the production of the long-lived isomers {sup 93m}Nb({1/2}{sup {minus}}, 16y), {sup 121m}Sn(11/2{minus}, 55 yr), {sup 166m}Ho(7-, 1200 yr), {sup 184m}Re(8+, 165 d), {sup 186m}Re(8+, 2{times}10{sup 5} yr), {sup 178m}Hf(16+, 31 yr), {sup 179m}Hf(25/2-, 25 d), {sup 192m}Ir(9+, 241 yr), all of which pose potential radiation activation problems in nuclear fusion reactors. We consider (n, 2n), (n,n{prime}), and (n, {gamma}) production modes and compare our results both with experimental data (where available) and systematic. We also investigate the dependence of the isomeric cross section ratio on incident neutron energy for the isomers under consideration. The statistical Hauser-Feshbach plus preequilibrium code GNASH was used for the calculations. Where discrete state experimental information was lacking, rotational band members above the isomeric state, which can be justified ...
1991-01-01
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive ...
2002-12-01
Advanced nuclear data for radiation-damage calculations
Energy Technology Data Exchange (ETDEWEB)
Accurate calculations of atomic displacement damage in materials exposed to neutrons require detailed spectra for primary recoil nuclei. Such data are not available from direct experimental measurements. Moreover, they cannot always be computed accurately starting from evaluated nuclear data libraries such as ENDF/B-V that were developed primarily for neutron transport applications, because these libraries lack detailed energy-and-angle distributions for outgoing charged particles. Fortunately, a new generation of nuclear model codes is now available that can be used to fill in the missing spectra. One example is the preequilibrium statistical-model code GNASH. For heating and damage applications, a supplementary code called RECOIL has been developed. RECOIL uses detailed reaction data from GNASH, together with angular distributions based on Kalbach-Mann systematics to compute the energy and angle distributions of recoil nuclei. The energy-angle distributions for ...
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler which can be sampled the tracer gas over arbitrary 12 time ...
1995-07-01
British Library Electronic Table of Contents (United Kingdom)
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
2011-01-01
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the simulated ablation procedure ranged from 25% higher to 15% lower than that determined by other authors. ...
2001-02-01
Safe Type of Transference for Spent Fuel
International Science & Technology Center (ISTC)
Safe Transference of Spent Fuel Assemblies from Near-Reactor Storage Pools to Long-term "Dry" Storage
Cryogenic liquid transfer termination apparatus
International Nuclear Information System (INIS)
Apparatus for termination of cryogenic liquid transfer from a liquid supply container to a storage-dispensing container is disclosed.
International Nuclear Information System (INIS)
The structural parameters of various Haegg phases (H or M_n_+_1AX_n phases) are studied experimentally by x-ray and electron spectroscopies, x-ray diffraction, and ab initio full potential as well as full mutiple scattering theoretical calculations. Experimentally it was found that the structure of all ternary compounds analyzed herein are relaxed. The values of the lattice parameters and relaxations obtained from ab initio calculations are in excellent agreement with those deduced from the analysis of the experimental data. The bonding scheme has been analyzed and the charge transfer between constituting atoms determined. It is demonstrated that the strength and electrical transport properties in these materials are principally governed by the metallic planes. For the solid solution (Ti_0_._5Nb_0_._5)_2AlC, the most salient result is that the basal planes are corrugated, which could explain the solid solution scattering ...
2005-01-01
The nucleon interaction and neutron matter from the renormalization group
We show that the renormalization group decimation of modern nucleon potential models to low momenta results in a unique nucleon interaction V_{low k}. This interaction is free of short-ranged singularities and can be used directly in many-body calculations. The RG scaling properties follow directly from the invariance of the scattering phase shifts. We discuss the RG treatment of Fermi liquids. The RG equation for the scattering amplitude in the two particle-hole channels is given at zero temperature. The flow equations are simplified by retaining only the leading term in an expansion in small momentum transfers. The RG flow is illustrated by first studying a system of spin-polarized fermions in a simple model. Finally, results for neutron matter are presented by employing the unique low momentum interaction V_{low k} as initial condition of the flow. The RG approach yields the amplitude for non-forward scattering, which is of great interest ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the transient heat transfer characteristics. Transient temperature data from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. Transient surface temperature was measured using the thin film thermocouples. At first, the transient heat flux rates calculated from the analysis method used in this paper were compared with the results from FEM. The results showed good agreement. Using this analysis method, the transient heat flux rates were calculated. The tests were performed at 1200 rpm with constant air flow. The parameters that were varied included the fuel rate and injection timing. Based on these results, the present paper discusses the mechanism of heat rejection in a direct-injection diesel engine. 8 refs., 16 figs.
1997-09-25
Energy Technology Data Exchange (ETDEWEB)
Experimental investigations are being conducted on a single-cylinder direct-injection diesel engine to examine the effects of combustion chamber specifications and swirl ratios on the heat release and transient heat transfer characteristics. Heat rejection was examined on the basis of heat release calculations using cylinder pressure time histories. Transient surface temperature data obtained from stationary locations in the piston and cylinder head were used as the basis for determining the transient heat flux rates. The results showed good agreement with the heat rejection calculated from cylinder pressure data and that transient heat flux in a piston cavity was reduced with the larger cavity diameter and a higher swirl ratio. On the other hand, a transient heat flux in a piston head was not changed by the cavity diameter and swirl ratio. 5 refs., 19 figs.
1997-09-25
Oxidation, volatilization, and redistribution of molybdenum from TZM alloy in air
Energy Technology Data Exchange (ETDEWEB)
The excellent high temperature strength and thermal conductivity of molybdenum-base alloys provide attractive features for components in advanced magnetic and inertial fusion devices. Refractory metal alloys react readily with oxygen and other gases. Oxidized molybdenum in turn is susceptible to losses from volatile molybdenum trioxide species, MoO{sub 3}(m), in air and the hydroxide, MoO{sub 2}(OH){sub 2}, formed from water vapor. Transport of radioactivity by the volatilization, migration, and re-deposition of these volatile species during a potential accident involving a loss of vacuum or inert environment represents a safety issue. In this report the authors present experimental results on the oxidation, volatilization and re-deposition of molybdenum from TZM in flowing air between 400 and 800 C. These results are compared with calculations obtained from a vaporization mass transfer model using chemical thermodynamic data for vapor ...
2000-01-01
Oxidation, Volatilization, and Redistribution of Molybdenum from TZM Alloy in Air
Energy Technology Data Exchange (ETDEWEB)
The excellent high temperature strength and thermal conductivity of molybdenum-base alloys provide attractive features for components in advanced magnetic and inertial fusion devices. Refractory metal alloys react readily with oxygen and other gases. Oxidized molybdenum in turn is susceptible to losses from volatile molybdenum trioxide species, (MoO3)m, in air and the hydroxide, MoO2(OH)2, formed from water vapor. Transport of radioactivity by the volatilization, migration, and re-deposition of these volatile species during a potential accident involving a loss of vacuum or inert environment represents a safety issue. In this report we present experimental results on the oxidation, volatilization and re-deposition of molybdenum from TZM in flowing air between 400 and 800°C. These results are compared with calculations obtained from a vaporization mass transfer model using chemical thermodynamic data for vapor pressures of MoO3(g) over ...
2000-01-01
On the off-design of a natural gas-fired combined cycle with CO{sub 2} capture
Energy Technology Data Exchange (ETDEWEB)
During the last 15 years cycles with CO{sub 2} capture have been in focus, due to the growing concern over our climate. Often, a natural gas fired combined cycle with a chemical absorption plant for CO{sub 2} capture from the flue gases have been used as a reference in comparisons between cycles. Neither the integration of the steam production for regeneration of amines in the combined cycle nor the off-design behaviour of such a plant has been extensively studied before. In this paper, the integration of steam production for regeneration of the amines is modelled at design load and studied in off-design conditions for a combined cycle. Different ambient conditions and part-load strategies and their influence on the cycle performance are also examined. Of particular interest is a novel strategy with the possibility of longer life of gas turbine blading, with marginal loss in efficiency. The off-design performance of the combined cycle is modelled in a rigorous way using a gas turbine ...
2007-04-15
Numerical heat transfer studies of PCMs used in a box-type solar cooker
Energy Technology Data Exchange (ETDEWEB)
Theoretical investigations on the phase change materials (PCMs) used as the heat storage media for box-type solar cookers have been conducted in this study. The selected PCMs are magnesium nitrate hexahydrate, stearic acid, acetamide, acetanilide and erythritol. For a two-dimensional simulation model based on the enthalpy approach, calculations have been made for the melt fraction with conduction only. Different materials such as glass, stainless steel, tin, aluminum mixed, aluminum and copper are used as the heat exchanger container materials in the numerical calculations. The large value of thermal conductivity of heat exchanger container material did not make a significant contribution on the melt fraction except for at very low thermal conductivities. Based on the theoretical results, stearic acid and acetamide are found to be good compatibility with latent heat storage system. It is also found that the initial temperature of PCM does not ...
2008-05-15
Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event
International Nuclear Information System (INIS)
In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the assessment are fuel bundle heat transfer model, ...
2001-10-01
Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator
Energy Technology Data Exchange (ETDEWEB)
Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity ...
2001-10-01
Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator
International Nuclear Information System (INIS)
Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity into the ...
2001-10-01
A simple model for strontium breakthrough on zeolite columns
The Process Waste Treatment Plant (PWTP) at the Oak Ridge National Laboratory is designed to remove radioactive contaminants, principally {sup 90}Sr, from process wastewater. Planned upgrades to the PWTP will use chabazite zeolite columns. Pilot-scale studies have shown that mass transfer zone lengths increase from 10 to about 30 cm as the superficial velocity increases from 5.5 to 22 cm/min. Calculations with a multicomponent equilibrium model showed that the distribution coefficient for strontium remains essentially constant over the process conditions, suggesting that a simple kinetic model (the Rosen long-bed solution) should adequately represent breakthrough behavior. Using a distribution coefficient of 4.87 L/g predicted by the equilibrium model, good agreement was found between experimental breakthrough curves and those calculated with the Rosen solution. This model allows prediction of bed depths and cycle times ...
1995-04-01
Radiant emittance of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The product of this ...
1994-12-31
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...
Transfer of elements into mother's milk; Transfer von Elementen in die Muttermilch
Energy Technology Data Exchange (ETDEWEB)
This research project aimed to determine the factors for the transfer of the elements silver (Ag), cerium (Ce), cobalt (Co), chrome (Cr), gallium (Ga), lanthanum (La), molybdenum (Mo), niobium (Nb), radium (Ra), ruthenium (Ru), antimony (sb), thorium (Th), titanium (Ti) and uranium (U) from food into the mother's milk. This factors will be used as a basic to check and derive activity values for the contamination of food and for radiation protection at working places of suckling women. For this purpose 19 mothers collected samples daily (2-8 weeks), using the duplicate method, of all the food they consumed as well as of their milk. After microwave-assisted digestion the element contents were analysed by mass-spectroscopy with inductive coupled plasma (ICP-MS). The results of the mothers who participate for more than 5 weeks were used to make a time lapse between the intake and transfer of the elements in the mothers ...
2000-08-01
A study of passive and inherent safety design concepts for advanced light= water reactors
Energy Technology Data Exchange (ETDEWEB)
The five thermal-hydraulic concepts chosen for conceptual study of advanced PWR systems have been studied as follows: (1) Critical Heat Flux in passive PWR Conditions: review of previous works (various of correlations, analysis of parametric trends) on CHF, assessment and improvement of CHF prediction models for round tubes, development of the prediction model on bundle CHF with considering the correction factor calculated from the tube data base, design and construction of the intermediate-pressure CHF experimental loop, extension of CHF data base by performing the experiments at low-flow, and low-quality conditions (2) Passive Cooling Concepts for Concrete Containment Systems: Selection of the external condenser by comparing and reviewing between passive cooling concepts for concrete containment system concepts, survey and review of previous studies (theoretical mechanism of condensation heat transfer and effect of non-condensable gases) on ...
1997-07-01
International Nuclear Information System (INIS)
With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone ...
2007-05-01
International Nuclear Information System (INIS)
The rapid circularization and synchronization of the stellar components in an eccentric binary system at the onset of Roche lobe overflow is a fundamental assumption common to all binary stellar evolution and population synthesis codes, even though the validity of this assumption is questionable both theoretically and observationally. Here we calculate the evolution of the orbital elements of an eccentric binary through the direct three-body integration of a massive particle ejected through the inner Lagrangian point of the donor star at periastron. The trajectory of this particle leads to three possible outcomes: direct accretion onto the companion star within a single orbit, self-accretion back onto the donor star within a single orbit, or a quasi-periodic orbit around the companion star, possibly leading to the formation of a disk. We calculate the secular evolution of the binary orbit in the first two cases and conclude that direct impact ...
2010-11-20
Study of heavy-ion reactions with the unstable Nuclei, {sup 11}Be and {sup 13}N
Energy Technology Data Exchange (ETDEWEB)
Heavy-ion reaction with unstable nuclei, {sup 13}N and {sup 11}Be, {sup 13}N+{sup 12}C and {sup 11}Be+{sup 12}C-{sup 10}Be+{sup 13}C were analyzed by a coupled-reaction-channel (CRC) method and formation of valence nucleon molecular orbital was studied by numerical analysing calculation. In this report, 1P1/2 (the ground state of {sup 13}N and {sup 13}C), 2s1/2 (the ground state of {sup 11}Be), 1d5/2 and 1d3/2 orbital were studied as one particle state of valance nucleon in {sup 13}N, {sup 13}C and {sup 11}Be. Moreover, d3/2 state, comparatively higher excited state, was contained into CRC calculation. The effect of this state on CRC scheme was proved very large. We developed new program code to obtain the numerical stable solution. It is necessary to about 200 MB (CRC equation) for {sup 11}Be+{sup 12}C{yields}{sup 10}Be+{sup 13}C and about 300 MB for discussion about molecular orbital. We show that the CRC calculation with ...
1996-06-01
International Nuclear Information System (INIS)
Results of self-consistent local-spin-density-functional calculations are reported for the first time for the Ni(110) surface, represented by one-, three-, and five-layer slabs. Calculations for one- and five-layer slabs of Ni(100) are also reported. The behavior of the surface magnetization with varying slab thickness elucidates the nature and origin of the surface magnetic moment. We predict a 13% enhancement of the Ni(110) surface magnetic moment compared to the bulk value. For the Ni(100) surface, we find a smaller surface enhancement about 7%, compared to bulk, which agrees with the results of Jepsen et al. The enhancement of surface magnetic moments on Ni(100) and Ni(110) surfaces is attributed to s-d dehybridization at the surface and to the presence of electrostatic shifts required to maintain layer-by-layer charge neutrality. We find that the total d-electron charge is the same in each layer, which contradicts the sp-to-d charge ...
Investigation of thermohydraulic parameters during natural convection cooling of TRIGA reactor
International Nuclear Information System (INIS)
Important steady-state thermohydraulic parameters of the TRIGA research reactor operating under natural convection mode of coolant flow were investigated using NCTRIGA computer code. Neutronic parameters used in preparing the input of NCTRIGA were taken from the analysis performed by 3-D Monte Carlo code MCNP4C. Benchmarking of the NCTRIGA calculated results were performed against the experimental data measured by the thermocouples in the instrumented fuel element (IFE) during the steady state operation of the reactor under natural convection mode of coolant flow. Various thermohydraulic parameters like the coolant velocity, flow rate and mass flow rate were generated for the hot channel as well as for the two channels comprising instrumented fuels. Calculated peak fuel temperatures at different power levels were compared with the measured values and also with the calculations performed by PARET code. Axial temperature ...
2006-09-01
The Use of Medical Images in Planning and Delivery of Radiation Therapy
UK PubMed Central (United Kingdom)
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
1997-09-01
Animal Models for Radiation Injury, Protection and Therapy
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
International Nuclear Information System (INIS)
Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health exposure ...
Electron-beam induced RAFT-graft polymerization of poly(acrylic acid) onto PVDF
Energy Technology Data Exchange (ETDEWEB)
This paper explores for the first time the post-radiation-induced-graft polymerization on solid substrate using reversible addition-fragmentation transfer (RAFT) mechanism. Radiation-induced graft polymerization onto polymers is a potentially interesting technique to create easily new materials from highly resistant polymers, e.g. surface graft polymerization of acrylic acid (AA) onto poly(vinylidene difluoride) (PVDF) improves its surface properties without losing its excellent mechanical properties. As a consequence of the radical nature of the polymerization processes it is difficult to control molecular weight of grafted chains, and therefore design and standardize the properties of the final product. RAFT polymerization is a suitable method to obtain monodisperse polymers. The ability of the RAFT agents to control the polymer chain length could be an interesting approach to improve the grafted polymers obtained by ...
2005-07-01
International Nuclear Information System (INIS)
Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant increase to 36.1% on the 15th day. In contrast, for photon beam ...
2008-09-01
International Nuclear Information System (INIS)
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV ...
2004-07-01
A study of flow boiling phenomena using real time neutron radiography
International Nuclear Information System (INIS)
The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and a similar flow ...
1346-01-01
International Nuclear Information System (INIS)
Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were subsequently interpolated into finer angular intervals for dose ...
2008-09-07
Relativistic corrections to the spectra and radiative transitions in quarkonia
International Nuclear Information System (INIS)
The author calculated the wavefunctions and the energy-spectra of c bar c and b bar b bound systems using the Hamiltonian proposed by Gupta, Radford and Repko (GRR). He writes the GRR Hamiltonian as H = H_o + H', where H_o includes the kinetic energy terms and the most dominant terms in the Hamiltonian. H' includes among other things the spin-spin, spin-orbit and the tensor terms in the Hamiltonian. The eigenvalue problem of H_o is solved by the variational method which makes use of a trial wave-function with eleven parameters. H' is then treated in the first order perturbation theory. The energy-spectra agree very well with experimental data. He also calculated the E1 and the M1 decay rates of these quarkonia. With relativistic corrections, the E1 transitions agree better with experiment. The dominant relativistic correction comes from the relativistic modification of the wave-function. The M1 transitions can be improved by using a large quark ...
Disposal of old heads for Daya Bay NPP
International Nuclear Information System (INIS)
The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding ...
Convolution/superposition using the Monte Carlo method
International Nuclear Information System (INIS)
The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator ...
2003-07-21
International Nuclear Information System (INIS)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...
2009-10-01
Energy Technology Data Exchange (ETDEWEB)
The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
The absorption of solar heat and the attendant thermal and mechanical loadings on the tubes of cavity receivers depend predominantly on the flux distribution of the incident solar radiation. For an axially symmetric cavity receiver with a parabolic dish collector, it is simple to determine the insolation pattern on the receiver internal surfaces if the system is ideal. In such a system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun's central ray impinges on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions cannot be achieved in practice, and therefore the feasible parabolic dish system is referred to as a real system although, in actual fact, it is only an approximation to any actual system. The purpose of this paper is to devise calculation principles which permit analysis of a receiver designed for ideal conditions to verify its structural ...
1990-11-01
Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis
International Nuclear Information System (INIS)
As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the ...
2009-07-01
Benchmarks and models for 1-D radiation transport in stochastic participating media
Energy Technology Data Exchange (ETDEWEB)
Benchmark calculations for radiation transport coupled to a material temperature equation in a 1-D slab and 1-D spherical geometry binary random media are presented. The mixing statistics are taken to be homogeneous Markov statistics in the 1-D slab but only approximately Markov statistics in the 1-D sphere. The material chunk sizes are described by Poisson distribution functions. The material opacities are first taken to be constant and then allowed to vary as a strong function of material temperature. Benchmark values and variances for time evolution of the ensemble average of material temperature energy density and radiation transmission are computed via a Monte Carlo type method. These benchmarks are used as a basis for comparison with three other approximate methods of solution. One of these approximate methods is simple atomic mix. The second approximate model is an adaptation of what is commonly called the ...
2000-08-21
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled to Mejatto. ...
1991-01-01
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a somatically significant ...
1991-11-01
Optimisation of imaging technique used in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, ...
2006-09-15
Optimisation of imaging technique used in direct digital radiography
International Nuclear Information System (INIS)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all images were of diagnostic quality, however, ...
2006-09-01
British Library Electronic Table of Contents (United Kingdom)
The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In the preparing stage of Final Safety Analysis Report (FSAR), the expected inventories of radwaste treatment systems are estimated. The inventory calculation plays an important role in the estimation of environmental radiation as well as nuclear power plant (hereafter referred to NPP) integrity, and further improvement of the public perception for NPP or radiation. The inventory has been accumulated and periodically measured for every NPP during the whole operation in Korea. But, a detailed analysis and database construction for the inventory have not still been carried out. For estimating the inventory change in this study, the radwaste treatment systems of Wolsung (hereafter referred to WS) nuclear power units 3 and 4 were selected as the reference systems. An analysis and prediction of the inventory change were performed for total activity released to environment during the whole operation. The linear regression ...
2006-07-01
International Nuclear Information System (INIS)
In the preparing stage of Final Safety Analysis Report (FSAR), the expected inventories of radwaste treatment systems are estimated. The inventory calculation plays an important role in the estimation of environmental radiation as well as nuclear power plant (hereafter referred to NPP) integrity, and further improvement of the public perception for NPP or radiation. The inventory has been accumulated and periodically measured for every NPP during the whole operation in Korea. But, a detailed analysis and database construction for the inventory have not still been carried out. For estimating the inventory change in this study, the radwaste treatment systems of Wolsung (hereafter referred to WS) nuclear power units 3 and 4 were selected as the reference systems. An analysis and prediction of the inventory change were performed for total activity released to environment during the whole operation. The linear regression ...
2006-11-02
Critical assessment of the Schroedinger picture of quantum mechanics
Energy Technology Data Exchange (ETDEWEB)
We provide an example in which the Heisenberg and the Schroedinger pictures of quantum mechanics give different results, thus confirming the statement of P.A.M. Dirac that the two pictures may lead to inequivalent results. We consider a one-dimensional nonrelativistic charged harmonic oscillator (frequency {omega}{sub 0} and mass m), and take into account the action of the radiation reaction and the vacuum electromagnetic forces on the charged oscillator. We show that the Heisenberg picture gives the correct value, {Dirac_h}{omega}{sub 0}/2, for the ground state energy of the harmonic oscillator in both cases of classical and quantized vacuum fields. In the case of the Schroedinger picture, considering classical vacuum fields, and using a simple calculation for the classical radiation reaction force that is valid in the limit of large mass (mc{sup 2} >> {Dirac_h}{omega}{sub 0}), we obtain the value ...
2002-12-16
Energy Technology Data Exchange (ETDEWEB)
During the past few years, the dual role that ozone plays in climate change has been becoming increasingly obvious. First, continuous thinning of the ozone layer has been evident, even in the high and middle latitudes in the northern hemisphere. Secondly, ozone is also a greenhouse gas, affecting radiative transfer. Increases in tropospheric ozone have a positive forcing, whereas decreases in stratospheric ozone cause a negative forcing. During the last six years, measurements on total ozone and the vertical distribution of ozone have been performed at the Sodankylae Observatory. At Jokioinen Observatory, measurements on total ozone have been performed since 1990 and measurements on the vertical distribution of ozone since 1993. The overall project has focused on extending the national data series on total ozone and the vertical distribution of ozone. At the same time, the study has contributed to the study of interannual variability of the ...
1996-12-31
Recent developments in the design of conceptual fusion reactors
International Nuclear Information System (INIS)
Since the first round of conceptual fusion reactor designs in 1973 - 1974, there has been considerable progress in design improvement. Two recent tokamak designs of the Wisconsin and Culham groups, with increased plasma beta and wall loading (power density), lead to more compact reactors with easier maintenance. The Reference Theta-Pinch Reactor has undergone considerable upgrading in the design of the first wall insulator and blanket. In addition, a conceptual homopolar energy storage and transfer system has been designed. In the case of the mirror reactor, there are design changes toward improved modular construction and ease of handling, as well as improved direct converters. Conceptual designs of toroidal-multiple-mirror, liner-compression, and reverse-field pinch reactors are also discussed. A design is presented of a toroidal multiple-mirror reactor that combines the advantages of steady-state operation and high-aspect ratio. The liner-compression reactor ...
Real-time neutron radiography at the Iea-R1 m nuclear research reactor
International Nuclear Information System (INIS)
A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- 0:09 mm. (author)
2003-06-01
PET/MRI hybrid imaging: devices and initial results
International Nuclear Information System (INIS)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...
2008-06-01
Numerical simulation of a 1200 MWth pulverised fuel oxy-firing furnace
Energy Technology Data Exchange (ETDEWEB)
The Oxycoal burner for pulverised coal combustion previously developed by the authors has been scaled up to typical power plant dimensions and a CFD study of pulverised coal combustion in a 1200 MWth oxy-firing furnace has been performed. The study revealed the importance of modelling the flue gas radiation behaviour for flue gas temperatures and wall heat transfer. This was done using a non-grey implementation of the Exponential Wide Band Model (EWBM). Typically, comparisons between air and oxy-fired furnaces point out that to obtain similar flame behaviour, the oxygen content in oxy-firing conditions should be increased until the same adiabatic flame temperature is reached. However, it was found that for these conditions, significantly increased wall heat fluxes can be the result. Furthermore, at gas temperatures comparable to air combustion, particle burnout is accelerated in oxy-firing due to the influence of heterogeneous gasification ...
2009-07-01
We present the results of three-dimensional hydrodynamical simulations of the final stages of inspiral in a black hole-neutron star binary, when the separation is comparable to the stellar radius. We use a Newtonian Smooth Particle Hydrodynamics (SPH) code to model the evolution of the system, and take the neutron star to be a polytrope with a soft (adiabatic index G=2 and G=5/3) equation of state and the black hole to be a Newtonian point mass. The only non-Newtonian effect we include is a gravitational radiation back reaction force, computed in the quadrupole approximation for point masses. We use irrotational binaries as initial conditions for our dynamical simulations, which are begun when the system is on the verge of initiating mass transfer and followed for approximately 23 ms. For all the cases studied we find that the star is disrupted on a dynamical time-scale, and forms a massive (the disc mass is approximately 0.2 solar masses) ...
2001-01-01
International Nuclear Information System (INIS)
The release of any potential radioactive pollutant to the environment during routine operation of a Nuclear Power Plant should be the subject of appropriate controls and assessments. It is impossible to monitor directly the dose contribution of normal releases because the environmental radioactivity levels are very small but source monitoring provides a means of assessing the radiation exposure of population groups, critical groups and individual members of the public. Derived emissions limits ( DELs ) are used to quantify the relationship between releases of radioactivity and doses to public - critical groups. CNE Cernavoda DELs are based on a pathway analysis conducted for Cernavoda site specific conditions and they were computed using a compartment transfer model. Annual air and water emissions for the most significant radionuclides between 1997 and 2008 are presented in terms of doses and can be observed that population doses are far below ...
2009-10-12
Investigation of a mineral melting cupola furnace. Part II. Mathematical modeling
Energy Technology Data Exchange (ETDEWEB)
A mathematical model of a mineral melting cupola furnace for stone wool production has been developed for improving cupola operation. The 1-D, first-engineering-principles model includes mass and heat balances for the gas phase, five solid phases, and four liquid phases. The gas and solid/liquid phases flow countercurrently. Seven chemical reactions account for the conversions of coke, iron oxide, limestone, and gaseous species. The heterogeneous reactions of coke conversion are limited by both kinetics and mass transport. Heat transfer between phases is modeled including both convection and radiation. The model predicts gas concentrations; mass flow rates; and temperature profiles of the solid, melt, and gas in the cupola, as well as heat loss to the water-cooled walls. Inputs to the model include the coke, rock, and blast air properties, the blast air amount, and the coke percentage in the charge. The unknown model parameters are estimated on ...
2003-12-24
Energy Technology Data Exchange (ETDEWEB)
Langmuir-Blodgett films have been made with 3-n-hexadecylpyrrole and 3-n-octadecylpyrrole monomers and copolymers with unsubstituted pyrrole made by chemical polymerization at the air-water interface on a subphase containing FeCl/sub 3/. Langmuir-Blodgett films consisting of mixtures of stearic acid and alkylsubstituted polythiophenes have also been made as bilayer films. The orientation of single and multilayer films on platinum substrates have been studied by Near Edge X-ray Absorption Fine Structure Spectroscopy which also gives information about charge transfer interactions between the aromatic groups and the metallic substrates. The alkylsubstituted pyrroles form highly ordered two-dimensional structures. FeCl/sub 3/ initiated copolymerization with unsubstituted pyrrole leads to a more disordered system. In the case of polythiophene-stearic acid bilayers, the stearic acid layers are highly ordered. The poly(alkyl thiophene) layers sandwiched between stearic ...
1988-01-01
International Nuclear Information System (INIS)
New physical objects, ispalators based on free soap films, exhibit persistent flows of the soap solution in open and closed volumes in air with additions of gases of the C_8F_1_8 type (p = 20 Torr) at temperature drops on the films of the order of tenths and hundredths of kelvin. The flows move continuously at a velocity of 5 - 20 cm s"-"1. It is found that the parts of an inclined ispalator film show anomalous behaviour upon heating: their weight increases and they move downward over the film, whereas the unheated parts of the film move upward. Continuous radial vortex flows accompanied by the formation and washing of the regions of a thin black film are observed on circular films in closed volumes upon their uniform external cooling by evaporating water for 5 - 10 hours. The rapid flows make film ispalators the efficient heat carriers, which operate at small temperature drops (tenths and hundredths of kelvin) and surpass copper in the amount of thermal energy being ...
2002-05-31
Energy Technology Data Exchange (ETDEWEB)
The present paper deals with the conversion of solar energy in a gas turbine plant with a parabolic dish collector. Particular consideration is devoted to the thermodynamic and mechanical design and partload behavior of the receiver. The incident sunlight is focussed by the parabolic dish and then beamed into the cavity receiver. Here the working medium of the gas turbine flows through tubes and is heated up to the receiver outlet temperature. The task of the receiver is to transfer the radiated energy as efficiently as possible to the working medium. Furthermore the required heating surface should be small as possible i.e. optimum use must be made of the tube material with respect to its state of stress. It is shown which geometric and thermodynamic plant parameters influence these two design criteria. An optimum receiver design is presented on the basis of the results thus obtained. Finally, the variations in receiver efficiency and tube ...
1984-06-01
Influence of germanium and oxygen impurities on the radiation hardening of monocrystalline silicon
International Nuclear Information System (INIS)
... defects doped materials germanium infrared radiation monocrystals neutron
Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles
International Nuclear Information System (INIS)
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
1980-06-01
duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
