WorldWideScience
2

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in ...

2011-01-01

3

Doublet III vacuum vessel neutral beam armor  

Science.gov (United States)

The evolution of the Doublet III neutral beam armor is followed from the initial design of a radiation cooled metallic tile to the present actively cooled graphite design. Results of the thermal and stress analyses that dictated the present design are reviewed.

1979-11-01

4

Observation of Spontaneous Brillouin Cooling  

CERN Document Server

While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is traditional, but ...

2011-01-01

6

Doublet III limiter/armor update  

Energy Technology Data Exchange (ETDEWEB)

The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.

1983-12-01

7

Theoretical investigations on improving performance of cooling systems for fuel cell vehicles; Theoretische Untersuchungen zur Kuehlleistungssteigerung durch innovative Kuehlsysteme fuer Brennstoffzellen-Elektrofahrzeuge  

Energy Technology Data Exchange (ETDEWEB)

In this work theoretical investigations are carried out for cooling systems, which are used in fuel cell vehicles. This work focuses mainly on the capability of increasing the heat rejection rate by using new alternative cooling systems and by improving the conventional cooling system. Fuel cell vehicles have a higher demand of heat rejection to the ambient than comparable vehicles with combustion engine. The performance of conventional liquid cooling systems, especially at high loads and high ambient temperatures, is often not sufficient anymore. Hence, cooling systems with improved performance are necessary for fuel cell vehicles. The investigations in this work are based on DaimlerChrysler's ''A-Class'' having a PEM-Fuel Cell system integrated. Specific computational models are developed for radiators and ...

2008-04-01

8

Experiments to investigate the effects of radiative cooling on plasma jet collimation  

CERN Document Server

Preliminary experiments have been performed to investigate the effects of radiative cooling on plasma jets. Thin (3 um - 5 um) conical shells were irradiated with an intense laser, driving jets with velocities > 100 km/s. Through use of different target materials - aluminium, copper and gold - the degree of radiative losses was altered, and their importance for jet collimation investigated. A number of temporally resoved optical diagnostics was used, providing information about the jet evolution. Gold jets were seen to be narrower than those from copper targets, while aluminium targets produced the least collimated flows.

2010-01-01

9

Is cold better ? - exploring the feasibility of liquid-helium-cooled optics.  

Energy Technology Data Exchange (ETDEWEB)

Both simulations and recent experiments conducted at the Advanced Photon Source showed that the performance of liquid-nitrogen-cooled single-silicon crystal monochromators can degrade in a very rapid nonlinear fashion as the power and for power density is increased. As a further step towards improving the performance of silicon optics, we propose cooling with liquid helium, which dramatically improves the thermal properties of silicon beyond that of liquid nitrogen and brings the performance of single silicon-crystal-based synchrotrons radiation optics up to the ultimate limit. The benefits of liquid helium cooling as well as some of the associated technical challenges will be discussed, and results of thermal and structural finite elements simulations comparing the performance of silicon monochromators cooled with liquid nitrogen and helium will be given.

1999-09-30

10

Thermal and radiation losses in a linear device  

Energy Technology Data Exchange (ETDEWEB)

An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high ...

1980-11-01

11

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

12

Nuclear reactor with external structure cooling by natural convection  

International Nuclear Information System (INIS)

The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.

13

Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation  

CERN Document Server

An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.

2010-01-01

14

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

15

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

16

Parametric study of radiative cooling of solid antihydrogen. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is localized and ...

1989-03-01

17

Venus surface power and cooling systems  

British Library Electronic Table of Contents (United Kingdom)

A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...

2007-01-01

18

Thermal gradient humidification-dehumidification desalination system  

Energy Technology Data Exchange (ETDEWEB)

A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative ...

1982-12-14

19

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

20

Effect of convective wall currents on the air quality of source ventilation. Einfluss konvektiver Wandstroemungen auf die Luftqualitaet bei Quellueftung  

Energy Technology Data Exchange (ETDEWEB)

With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)

1993-07-01

21

Measuring characteristics on emissivity using infrared thermometer for RCCS  

International Nuclear Information System (INIS)

In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured ...

2004-12-01

22

Modeling, numerical simulation and experimental verification of the unsteady cooling of a solid body in quiescent ambient air  

Energy Technology Data Exchange (ETDEWEB)

The scope of the present article is two-fold. Firstly, to conduct an experiment to provide the temperature-time history of the cooling of a hot ball bearing in quiescent ambient air. Secondly, to predict the temporal variation of the bearing under the hypothesis of natural convection, radiation or natural convection coexists with radiation for a non-vanishing total hemispherical emissivity of the surface of the bearing. Numerical solutions of the three governing nonlinear lumped heat equations were carried out with a Runge-Kutta-Fehlberg (RKF45) algorithm accounting for automatic step size control. The experimental data was obtained with chrome steel ball bearings of diameter 0.953 cm (7/16 in) heated in an electric oven to a pre-set temperature. The heated bearing was exposed later to ambient air at atmospheric temperature and pressure. (orig.)

2004-07-01

23

Solar energy apparatus with apertured shield  

Energy Technology Data Exchange (ETDEWEB)

This paper describes in an apparatus for absorbing a beam of concentrated solar energy and which includes a cavity receiver with an inlet for transmission thereinto of solar radiation, a protective apertured shield means about the inlet. It comprises: rigid support means fixed to the periphery of the inlet and projecting radially inwardly therefrom to define a generally central aperture area through which the solar radiation can pass into the cavity receiver; and non-structural blanket means spread over the rigid support means between the periphery of the inlet and the aperture area, the material having a high temperature capability and providing for infra-red radiation insulation, while remaining relatively cool when subjected to solar radiation.

1989-07-25

24

Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band ...

1987-05-01

25

Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, ...

1985-01-01

26

Solar power station. Sonnenkraftwerk  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a solar power station with a hollow solar heater, which has reflected radiation coming in, focussed by a mirror through the inlet opening. To match the differing solar radiation during the day, the inlet opening can be adjusted by changing its cross-section. This is done by at least two thick flat circular parts which can move relative to each other which are preferably movable relative to each other in pairs on a common rail and which are cooled by a coolant which is the working medium for absorbing solar energy.

1982-02-25

27

Radiolysis of neutron irradiated lithium solutions  

International Nuclear Information System (INIS)

In the Aqueous Self-Cooled Blanket (ASCB) concept, an aqueous "6Li solution in a metallic structure is used as a shielding-breeding blanket for fusion reactors. The experimental results of this study indicate that the radiolytic gas production in an ASCB will be proportional to the absorbed radiation energy. The observed radiation chemical yields allow the preliminary estimation of the radiolysis effects for a specific ASCB design. Contrary to the theoretical predictions, the use of hydrogen as a cover gas at up to 1 MPa had no measurable effect on the radiolytic gas production. Probably it will thus not be possible to suppress the radiolytic decomposition of a low-pressure ASCB by the addition of hydrogen. Catalytic recombination will be required. (orig.).

28

The numerical simulation on low-level radioactive waste water, low-temperature cooling water drained effect of implement from the Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

In this paper, we calculated the radioactive concentration distribution of radioactive waste water, the temperature distribution of drained cooling water and the effect of implement from the Daya Bay Nuclear Power Plant on nearby waters range, discussed and analysed some problems of computational results and computation with Alternating Direction Implicit Method (ADI). The contents of the article included: the establishment of two-dimension tidal current equation, radioactive waste water pollutant dispersion equation and cooling water heat convection diffusion equation, the numerical difference calculation model of tidal current field, concentration field as well as temperature field, effect impingement with ADI method, numerical calculation results. The result of research showed that: when the Daya Bay Nuclear Power Plant is on normal operation and after the low level radioactive waste water and low temperature cooling ...

29

Lifting the lid off the Windscale AGR  

Energy Technology Data Exchange (ETDEWEB)

With the lifting of the top dome of the Windscale (AGR) Advanced Gas-cooled Reactor earlier this year, the decommissioning team has begun to dismantle the heaviest of the reactor components. In defining the tasks involved, the most important criterion was to minimise the radiation exposure expected to be received by the team members. The manager of the WAGR decommissioning project describes the preparation undertaken and the final lifting of the top dome in this article. (author).

1991-10-01

30

Improvements in or relating to refractory oxide protective coatings for fuel can  

International Nuclear Information System (INIS)

An improved coating for Advanced Gas Cooled Nuclear Reactor austenitic stainless steel fuel cans is described which, tests have shown, inhibits the deposition of carbon on the cans in carbon-containing ionising radiation environments. The coating comprises a refractory oxide which has been prepared by a vapour phase condensation method, in combination with a noble metal. (U.K.).

31

Heat transfer  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer has emerged as a leading-edge technology supporting the rapid pace of developments in science and engineering ranging from energy production to electronic cooling. Subjects covered at the 6th UK National Conference on heat transfer held at Edinburgh from 15-16 September 1999 include: convection; boiling and evaporation; condensation; numerical techniques; heat exchangers; radiation and combustion; conduction; two-phase flow and heat transfer augmentation. Fifteen of the papers are abstracted here.

1999-07-01

32

Heat loss from an open cavity  

Energy Technology Data Exchange (ETDEWEB)

Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, ...

1995-12-01

33

Opto-acoustic recanilization delivery system  

Energy Technology Data Exchange (ETDEWEB)

Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area ...

2002-01-01

34

Method for determining hydrogen mobility as a function of temperature in superconducting niobium cavities  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.

2008-03-11

35

A He-gas Cooled, Stationary Granular Target  

CERN Document Server

In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.

2003-01-01

37

A cryocondensation pump for the DIII-D Advanced Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m{sup 2} liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The whole pump is ...

1992-03-01

38

Fundamental R and D program on water chemistry of supercritical pressure water under radiation field  

International Nuclear Information System (INIS)

In a supercritical water-cooled reactor, property of water changes significantly around the critical point. It is expected that irradiation and change of water property will affect the chemistry and material corrosion. Deep understanding of interactions between supercritical water and materials under irradiation is important. However, comprehensive data on radiolysis, kinetics, corrosion and thermodynamics have not been obtained due to the severe experimental condition. To get such data by experiments and computer simulations, a national program funded by Ministry of Education, Culture, Sports, Science and Technology (MEXT) has been started since December 2002. (author)

2003-09-15

39

Development of superconducting cryo-electron microscope and its applications  

International Nuclear Information System (INIS)

Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.).

1988-01-01

40

Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization  

CERN Document Server

Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the potential and the ...

2005-01-01

41

Atomic processes in high temperature plasmas  

International Nuclear Information System (INIS)

Much theoretical and experimental efforts have been expended in recent years to study those atomic processes which are specially relevant to understanding high temperature laboratory plasmas. For magnetically confined fusion plasmas, the temperature range of interest spans from the hundreds of eV at plasma edges to 10 keV at the center of the plasma, where most of the impurity ions are nearly fully ionized. These highly stripped ions interact strongly with electrons in the plasma, leading to further excitation and ionization of the ions, as well as electron capture. Radiations are emitted during these processes, which easily escape to plasma container walls, thus cooling the plasma. One of the dominant modes of radiation emission has been identified with dielectronic recombination. This paper reviews this work.

1990-01-01

42

Cooling facility for reactor container  

International Nuclear Information System (INIS)

Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the ...

1993-05-07

43

Modeling and analysis of heat transfer from the MHTGR core through a steel reactor vessel to the reactor cavity cooling system  

International Nuclear Information System (INIS)

The commercial Modular High Temperature Gas-Cooled Reactor (MHTGR) achieves improved reactor safety performance and reliability by utilizing an integrated sequence of completely passive thermal storage and heat transfer mechanisms to reject decay heat in the event that all its active cooling systems fail to operate. During such events, the initial heatup transient in the core is followed by a quasi-steady state cooldown process which, if uninterrupted, can continue for several days. A buoyancy-driven natural convection cooling system called the RCCS facilitates the continuous heat removal by circulating ambient air through the reactor cavity, where it is heated and then exhausted to the outside environment. The peak thermal load on the RCCS occurs approximately at the time that the vessel reaches its highest temperature. To confirm the adequacy of the RCCS design, detailed analytical models were developed to simulate the ...

1994-08-01

44

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...

2004-10-13

45

Heat rejection system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.

1980-01-22

46

Evaluation of Two Microclimate Cooling Air Vests on a Heated ...  

Science.gov (United States)

... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...

1992-12-01

47

A MODEL OF THE SPECTRAL EVOLUTION OF PULSAR WIND NEBULAE  

International Nuclear Information System (INIS)

We study the spectral evolution of pulsar wind nebulae (PWNe) taking into account the energy injected when they are young. We model the evolution of the magnetic field inside a uniformly expanding PWN. Considering time-dependent injection from the pulsar and coolings by radiative and adiabatic losses, we solve the evolution of the particle distribution function. The model is calibrated by fitting the calculated spectrum to the observations of the Crab Nebula at an age of a thousand years. The spectral evolution of the Crab Nebula in our model shows that the flux ratio of TeV #gamma#-rays to X-rays increases with time, which implies that old PWNe are faint in X-rays, but not in TeV #gamma#-rays. The increase of this ratio is because the magnetic field decreases with time and is not because the X-ray emitting particles are cooled more rapidly than the TeV #gamma#-ray emitting particles. Our spectral evolution model matches ...

2010-06-01

48

Thermal performance of automotive aluminium plate radiator  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of heat exchanger configurations that can help augment heat ...

2005-06-01

49

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the ...

2007-11-05

50

Heat transfer augmentation by gas-particle two-phase flow  

International Nuclear Information System (INIS)

The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat transfer mode in high ...

1995-06-01

51

MR-6 Type Fuel Elements Cooling in Natural Convection Conditions after Reactor Shutdown  

International Nuclear Information System (INIS)

... Natural convection cooling of the channel type reactor performed with the fuel

1992-08-03

52

Impingement-Film Heat Transfer Investigation.  

Science.gov (United States)

... Abstract : This report covers the investigation of an impingement-film cooling system designed to cool the exhaust ducts of turboshaft engines ...

1973-12-01

53

Design and performance tests of flap value for HANARO natural circulation cooling  

International Nuclear Information System (INIS)

... [2] Hee Taek Chae, et al., "On the Natural Convection Cooling in HANARO;

1999-09-06

54

Battery Thermal Management System Design Modeling  

Energy Technology Data Exchange (ETDEWEB)

Looks at the impact of cooling strategies with air and both direct and indirect liquid cooling for battery thermal management.

2006-11-01

55

Statistical analyses of coads wind data in coastal regions of the United States  

Energy Technology Data Exchange (ETDEWEB)

In the study, wind data from the Comprehensive Ocean-Atmosphere Data Set (COADS) are used to determine atmospheric circulation changes which are empirically associated with the air temperature changes. Some understanding of the natural processes which produce climate change is anticipated from the study of these associations. Systematic changes of wind in US coastal regions with periods of climate warming and cooling suggest circulation changes, in addition to carbon dioxide-controlled radiation effects, could produce the climate changes indicated by air temperature. A statistical procedure for analyses of COADS was used to determine decade-period vector wind-field differences from the COADS record period. The statistical procedure for these analyses is explained and the wind differences are compared to summaries of mid-Atlantic coast island-station observations.

1992-08-01

56

Radiation yield of oxygen-based radicals in hyperquenched glassy water gamma-irradiated at 77 K  

Energy Technology Data Exchange (ETDEWEB)

Hyperquenching of liquid water with cooling rates of 10{sup 6}-10{sup 7} K s{sup -1} yields glassy water. Upon {gamma}-irradiation at 77 K, the only paramagnetic species accumulating in hyperquenched glassy water are the hydroxyl and hydroperoxyl radicals. There are no hydrogen atoms or electrons seen by the ESR technique. For irradiation doses up to about 70 kGy, the relative contributions of hydroxyl and hydroperoxyl radicals to the total amount of paramagnetic species remain virtually constant. The total amount of paramagnetic species, n, is sublinear in dose, d, well approximated by n=8.55x10{sup 16}d{sup 0.8} for n in spin g{sup -1} and d in kGy.

1998-12-01

57

Plasma diagnostics by spectra from LHD and atomic data  

International Nuclear Information System (INIS)

We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)

2009-04-01

58

On the evolution of supernova remnants: Pt. 2  

International Nuclear Information System (INIS)

Supernova explosions within wind-driven bubbles are studied with 2D hydrodynamical calculations. Two different density distributions for the ejecta are considered: (i) a smooth, unfragmented power-law stratification, and (ii) a fragmented distribution. As in 1D models, the presence of the shell of interstellar swept-up matter causes the rapid evolution of the remnant to the radiative phase. The main 2D effects, for both fragmented and unfragmented ejecta, include: (i) substantial chaotic deviations from a purely radial flow in the remnant interior, (ii) efficient turbulent mixing between the ejecta and the shocked wind, resulting in homogenization of the former wind cavity, and (iii) severe distortion of the wind-driven shell by cooling and Rayleigh-Taylor instabilities. (author).

59

Heat-transfer augmentation in rod bundles near grid spacers  

International Nuclear Information System (INIS)

Heat-transfer augmentation by straight grid spacers in rod bundles is studied for single-phase flow and for post-critical heat flux dispersed flow. The heat transfer effect of swirling grid spacers in single-phase flow is also examined. Governing heat-transfer mechanisms are analyzed, and predictive formulations are established. For single-phase flow, the local heat transfer at a straight spacer and at its upstream or downstream locations are treated separately. The effect of local velocity increasing near swirling spacer is considered. For post critical heat flux (CHF) dispersed flow, the heat transfer by thermal radiation, fin cooling, and vapor convection near the spacer are calculated. The predictions are compared with experimental data with satisfactory agreement.

1982-01-01

60

Development of a solar thermal storage system suitable for the farmhouse heating in northeast China  

Energy Technology Data Exchange (ETDEWEB)

This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the use of renewable energy.

2010-07-01

61

Considerations referring to chemical descaling of filmed carbon steels  

International Nuclear Information System (INIS)

Under operational conditions in nuclear power plants, the carbon steel components of the primary and secondary circuits react with high temperature cooling agent forming several iron oxides and oxyhydroxides. These deposits can result in tubes' constrictions, pitting and intergranular corrosion and finally to heat transfer reducing and increasing of radiation fields around the circuits, as well. The descaling process involves the chemical dissolution of the corrosion deposits by means of diluted organic acidic solutions containing usually a carboxylic acid, a reductant and one or more corrosion inhibitors. To evaluate the removing rates of these superficial films two types of methods were used, the gravimetric and potentiodynamic techniques. By correlating the experimental results, we established the chemical composition of descaling solution and two models of mechanisms applicable to our specific conditions. (authors)

2009-10-12

62

Atmospheric chemistry on Venus, Earth, and Mars: Main features and comparison  

British Library Electronic Table of Contents (United Kingdom)

This paper deals with two common problems and then considers major aspects of chemistry in the atmospheres of Mars and Venus. (1) The atmospheres of the terrestrial planets have similar origins but different evolutionary pathways because of the different masses and distances to the Sun. Venus lost its water by hydrodynamic escape, Earth lost CO"2 that formed carbonates and is strongly affected by life, Mars lost water in the reaction with iron and then most of the atmosphere by the intense meteorite impacts. (2) In spite of the higher solar radiation on Venus, its thermospheric temperatures are similar to those on Mars because of the greater gravity acceleration and the higher production of O by photolysis of CO"2. O stimulates cooling by the emission at 15@mm in the collisions with CO"2. ...

2011-01-01

63

Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report  

Energy Technology Data Exchange (ETDEWEB)

Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.

1987-01-01

64

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished within the range of the limit of ...

1990-03-01

65

Irradiation-effects considerations for the SP-100 space reactor  

International Nuclear Information System (INIS)

The Sp-100 reactor is a lithium-cooled high-temperature fast-spectrum reactor. The fuel is UN. The cladding is fabricated from PWC-11, a Nb alloy, as are all the primary structural components. A reactor lifetime of up to ten years with an operating temperature of 1370 K is required. The accumulated fluence is expected to be 6 x10"2"2 n/cm"2. The damage, which could result in swelling or embrittlement, anneals out as fast as it occurs for the majority of the structure. This has been confirmed by earlier radiation testing. A number of components, however, are exposed to lower temperatures and the reactor design and materials selection for these components must take this into consideration. Radiation effects must also be considered for the UN fuel, bearing materials, etc. To data an instrumented experiment, MOTO 1000A, has been conducted in the FFTF reactor and as uninstrumented experiment SPM-1 in the EBR-II reactor. In this ...

1992-03-01

66

The effects of various cooling strategies on surface roughness and tool wear during soft materials milling  

British Library Electronic Table of Contents (United Kingdom)

This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the surface roughne...

2009-01-01

67

Synthesis, characterization and optical properties of a high NIR reflecting yellow inorganic pigment: Mo"6"+ doped Y_2Ce_2O_7 as a cool colorant  

International Nuclear Information System (INIS)

Full text: Pigments possessing the ability to confer high solar reflectance have received considerable attention in recent years. The inorganic class of NIR reflective pigments are mainly metal oxides and are primarily employed in two applications: (i) visual camouflage and (ii) reducing heat build up. More than half of the solar radiation consists of near-infrared radiation (52%), the remaining being 43% visible light and 5% ultraviolet radiation. Over heating due to solar radiation negatively affects comfort in the built environment and contributes substantially to electrical consumption for air conditioning and release of green house gases. A pigment which has strong reflections in the NIR region (780-2500 nm) can be referred to as a 'cool' pigment. However, most of the NIR reflective inorganic pigments particularly yellow (eg. cadmium yellow, lead chromate, chrome titanate ...

2010-11-24

68

THE BURST MODE OF ACCRETION AND DISK FRAGMENTATION IN THE EARLY EMBEDDED STAGES OF STAR FORMATION  

International Nuclear Information System (INIS)

We revisit our original papers on the burst mode of accretion by incorporating a detailed energy balance equation into a thin-disk model for the formation and evolution of circumstellar disks around low-mass protostars. Our model includes the effect of radiative cooling, viscous and shock heating, and heating due to stellar and background irradiation. Following the collapse from the prestellar phase allows us to model the early embedded phase of disk formation and evolution. During this time, the disk is susceptible to fragmentation, depending upon the properties of the initial prestellar core. Globally, we find that higher initial core angular momentum and mass content favors more fragmentation, but higher levels of background radiation can moderate the tendency to fragment. A higher rate of mass infall onto the disk than that onto the star is a necessary but not a sufficient condition for disk fragmentation. More locally, ...

2010-08-20

69

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows ...

70

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

71

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

72
73

A theoretical evaluation of solar-powered desiccant cooling in the United Kingdom  

Energy Technology Data Exchange (ETDEWEB)

Desiccant cooling is a potentially environmentally friendly technology that can be used to condition the internal environment of buildings. Unlike conventional air conditioning systems, which rely on electrical energy to drive the cooling cycle, desiccant cooling is a heat-driven cycle. This paper follows on from an initial study by the authors, and uses real meteorological data to evaluate the potential in the United Kingdom of using solar energy to drive the desiccant cooling cycle. Through the use of parametric studies, the paper investigates the energy consumption and costs associated with desiccant cooling. (author)

1999-07-01

74

DESIGN OF A CONVECTIVE COOLING SYSTEM FOR A MACH 6 - NASA ...  

Science.gov (United States)

Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...

75

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the ...

1983-08-26

76

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the charcoal and heat is ...

2006-11-13

77

FFTF operational results: startup to 100 MWd/kg  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated beyond expectations; it achieved a cycle capacity factor of ...

78

Effective stress of a 4.2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube subjected to eddy current load in a quenching dipole requires an optimum diameter ...

1993-05-01

79

Effective stress of a 4. 2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall's resistivity requirement ([sigma]*t = 2E5 [Omega][sup [minus]1]). For a 4.2 K beam tube the Cu thickness is 100 [mu]m (RRR=30,6.7 T, [sigma]=2E9[Omega][sup [minus]1]m[sup [minus]1]). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube subjected to eddy current load in a quenching dipole requires an optimum ...

1993-05-01

80

Suzaku and Optical Spectroscopic Observations of SS 433 in the 2006 April Multiwavelength Campaign  

CERN Document Server

We report results of the 2006 April multi-wavelengths campaign of SS 433, focusing on X-ray data observed with Suzaku at two orbital phases (in- and out-of- eclipse) and simultaneous optical spectroscopic observations. By analyzing the Fe25 K_alpha lines originating from the jets, we detect rapid variability of the Doppler shifts, dz/dt ~ 0.019/0.33 day^-1, which is larger than those expected from the precession and/or nodding motion. This phenomenon probably corresponding to "jitter" motions observed for the first time in X-rays, for which significant variability both in the jet angle and intrinsic speed is required. From the time lag of optical Doppler curves from those of X-rays, we estimate the distance of the optical jets from the base to be ~(3-4) \\times 10^14 cm. Based on the radiatively cooling jet model, we determine the innermost temperature of the jets to be T_0 = 13 +/- 2 keV and 16 +/- 3 keV (the average of the blue and red jets) ...

2010-01-01

81

Strong-field quantum-electrodynamic processes in aligned crystals  

Energy Technology Data Exchange (ETDEWEB)

When a highly collimated beam of particles is aimed along the atomic rows of an aligned single crystal, the averaging effect of high speed motion results, to the lowest order of approximation, in crystal electric fields which are transverse to the atomic rows. The enormous magnitude of the crystal transverse electric fields is unsurpassed by any other known earth-bound macroscopic sources. For example, the field strengths along the <100> axis of tungsten at 77 K approach 9{center dot}10{sup 13}V/m. Thus quantum electrodynamic (QED) processes in strong fields which are thought to occur only in the extra-terrestrial environment can now be investigated in the laboratory. Here we review the results of measurements performed at the SPS facility in CERN using highly collimated beams of electrons, positrons and photons in the 20-200 GeV range, and germanium crystals cooled to 77 K with thicknesses ranging from 0.07 mm to 1.40 mm. The focus is on the simplest ...

1989-01-01

82

Shielding and Criticality Safety Analysis of KSC-1 Cask for the High Burnup PWR Spent Fuels  

International Nuclear Information System (INIS)

KSC-1 (KAERI Shipping Cask-1) was designed and manufactured with a pure domestic technology in 1985 in order to transport a PWR spent fuel assembly from nuclear power plant to PIEF (Post-Irradiation Examination Facility) of KAERI. Since the first transportation of the fuel assembly from Kori-1 NPP was carried out by the cask in 1987, 19 shipments for the PWR spent fuels have been done successfully by now. Maximum discharge burnup of PWR in Korea has been extended from the late 1990s in order to reduce the cost of power generation. From this cause, allowable design values of the initial enrichment and the cooling time for the cask have been changed three times: year 2003, 2007 and 2010. Radiation shielding and criticality of KSC-1 were analyzed for all the PWR fuel type irradiated in Korea NPP to renew the design approval

2010-10-01

83

Results of second regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for ...

1988-01-01

84

Results of second regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of enrichment from 3.15 wt.% to 3.4 wt.% for ...

1988-08-01

85

Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant  

International Nuclear Information System (INIS)

This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and maximum dose) for the ...

1987-01-01

86

Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, average dose and maximum dose) for the ...

1987-09-01

87

Observations of toroidal and poloidal rotation in the high-beta tokamak Torus II  

Science.gov (United States)

The macroscopic rotation of plasma in a toroidal containment device is an important feature of the equilibrium. Toroidal and polidal rotation in the high-beta tokamak Torus II is measured experimentally by examining the Doppler shift of the 4685.75 A He II line emitted from the plasma. The toroidal flow at an average velocity of 1.6 x 10/sup 6/ cm/sec, a small fraction of the ion thermal speed, moves in the same direction as the toroidal-plasma current. The poloidal flow follows the ion diamagnetic current direction, also at an average speed of 1.6 x 10/sup 6/ cm/sec. In view of certain ordering parameters, the toroidal flow is compared with predictions from neoclassical theory in the collisional, Pfirsch-Schluter regime. The poloidal motion, however, results from an E x B drift in a positive radial electric field, approaching a stable ambipolar state. This radial electric field is determined from theory by using the measured poloidal velocity. Mechanisms for the time evolution of ...

1983-01-01

88

Observations of toroidal and poloidal rotation in the high beta tokamak Torus II  

Science.gov (United States)

The macroscopic rotation of plasma in a toroidal containment device is an important feature of the equilibrium. Toroidal and poloidal rotation in the high beta tokamak Torus II is measured experimentally by examining the Doppler shift of the 4685.75 A He II line emitted from the plasma. The toroidal flow at an average velocity of 1.6 x 10/sup 6/ cm/sec, a small fraction of the ion thermal speed, moves in the same direction as the toroidal plasma current. The poloidal flow follows the ion diamagnetic current direction, also at an average speed of 1.6 x 10/sup 6/ cm/sec. In view of certain ordering parameters, the toroidal flow is compared with predictions from neoclassical theory in the collosional, Pfirsch-Schluter regime. The poloidal motion, however results from an E x B drift in a positive radial electric field, approaching a stable ambipolar state. This radial electric field is determined from theory by using the measured poloidal velocity. Mechanisms for the time evolution of ...

1983-01-01

89

Mechanical Engineering and Design of the LHC Phase II Collimators  

CERN Document Server

Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time and improve beam ...

2010-01-01

90

Investigation of a mineral melting cupola furnace. Part II. Mathematical modeling  

Energy Technology Data Exchange (ETDEWEB)

A mathematical model of a mineral melting cupola furnace for stone wool production has been developed for improving cupola operation. The 1-D, first-engineering-principles model includes mass and heat balances for the gas phase, five solid phases, and four liquid phases. The gas and solid/liquid phases flow countercurrently. Seven chemical reactions account for the conversions of coke, iron oxide, limestone, and gaseous species. The heterogeneous reactions of coke conversion are limited by both kinetics and mass transport. Heat transfer between phases is modeled including both convection and radiation. The model predicts gas concentrations; mass flow rates; and temperature profiles of the solid, melt, and gas in the cupola, as well as heat loss to the water-cooled walls. Inputs to the model include the coke, rock, and blast air properties, the blast air amount, and the coke percentage in the charge. The unknown model parameters are estimated on ...

2003-12-24

91

Film ispalators  

International Nuclear Information System (INIS)

New physical objects, ispalators based on free soap films, exhibit persistent flows of the soap solution in open and closed volumes in air with additions of gases of the C_8F_1_8 type (p = 20 Torr) at temperature drops on the films of the order of tenths and hundredths of kelvin. The flows move continuously at a velocity of 5 - 20 cm s"-"1. It is found that the parts of an inclined ispalator film show anomalous behaviour upon heating: their weight increases and they move downward over the film, whereas the unheated parts of the film move upward. Continuous radial vortex flows accompanied by the formation and washing of the regions of a thin black film are observed on circular films in closed volumes upon their uniform external cooling by evaporating water for 5 - 10 hours. The rapid flows make film ispalators the efficient heat carriers, which operate at small temperature drops (tenths and hundredths of kelvin) and surpass copper in the amount of thermal energy ...

2002-05-31

92

FFTF [Fast Flux Test Facility] cesium trap design, installation, and operating experience  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400-MWt, sodium-cooled reactor located on the Hanford Site near Richland, Washington, USA. The FFTF is owned by the U.S. Department of Energy and is operated by the Westinghouse Hanford Company. The FFTF was designed to test fuels and materials for use in liquid metal reactors. Since initial operation in 1982, anticipated breaches of experimental fuel pins have released fission products, including cesium, into the primary sodium. Because of its high volatility, cesium vaporizes into the cover gas space, where it condenses on components and equipment and is transported into the cover gas outlet. Because of the long half-life of "1"3"7Cs, these deposits result in long-term, local radiation levels that make contact maintenance difficult. Thus, a cesium trap was installed in FFTF to reduce the cesium level in the sodium. The trap could also permit a Run Beyond Cladding Breach (RBCB) program without ...

1988-10-17

93

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions  

Science.gov (United States)

New comparative tests on two different types of solar collectors are presented in this paper. A standard glazed flat plate collector and an evacuated tube collector are installed in parallel and tested at the same working conditions; the evacuated collector is a direct flow through type with external compound parabolic concentrator (CPC) reflectors. Efficiency in steady-state and quasi-dynamic conditions is measured following the standard and it is compared with the input/output curves measured for the whole day. The first purpose of the present work is the comparison of results in steady-state and quasi-dynamic test methods both for flat plate and evacuated tube collectors. Besides this, the objective is to characterize and to compare the daily energy performance of these two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar ...

2010-08-15

94

Actinides in liquid waste formed in the regeneration of nuclear fuel from a VVER-1000 reactor  

International Nuclear Information System (INIS)

In the radiochemical reprocessing of spent fuel from nuclear reactors, a considerable amount of liquid, solid, and gaseous waste is formed; this waste is potentially dangerous to humans and requires the development of special and complex technological techniques for its localization and reliable long-term storage. The most hazardous are liquid wastes of high specific activity - water-tailings solutions obtained in the first cycle of extraction after the removal of uranium and plutonium. These solutions contain more than 99.9% of all the other transuranic elements - isotopes of neptunium, americium, and curium. Where necessary, some fission products and actinides may be removed from wastes of high specific activity for subsequent use. The quantity, composition, and activity of these wastes varies within broad limits, depending on the type and power of the reactor, the initial nuclide composition of the fuel, and its specific energy yield, the regeneration technology, and other factors. ...

95

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of approximately 1.5% (95% ...

2000-01-01

96

Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).

1987-01-01

97

Chalk Point Cooling Tower Project. Volume 2. Cooling Tower Drift Dye Tracer Experiment, June 16 and 17, 1977.  

Science.gov (United States)

A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aero...

1977-01-01

99

Achieving more reliable operation of turbine generators at nuclear power plants by improving the water chemistry of the generator stator cooling system  

British Library Electronic Table of Contents (United Kingdom)

Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.

2011-01-01

100

Economic evaluation of four types of dry/wet cooling applied to the 5-MWe Raft River geothermal power plant  

Energy Technology Data Exchange (ETDEWEB)

A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water surface condenser currently installed at the Raft River Plant. The other two systems had ...

1982-07-01

101

HANARO cooling features: design and experience  

International Nuclear Information System (INIS)

In order to achieve the safe core cooling during normal operation and upset conditions, HANARO adopted an upward forced convection cooling system with dual containment arrangements instead of the forced downward flow system popularly used in the majority of forced convection cooling research reactors. This kind of upward flow system was selected by comparing the relative merits of upward and downward flow systems from various points of view such as safety, performance, maintenance. However, several operational matters which were not regarded as serious at design come out during operation. In this paper are presented the design and operational experiences on the unique cooling features of HANARO. (author)

1999-08-01

102

Closed loop air cooling system for combustion turbines  

Energy Technology Data Exchange (ETDEWEB)

Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts.

1998-01-01

103

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

105
106

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

107

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type enclosure and showed ...

108

Use of a temperature-initiated passive cooling system (TIPACS) for the modular high-temperature gas-cooled reactor cavity cooling system (RCCS)  

Energy Technology Data Exchange (ETDEWEB)

A new type of passive cooling system has been invented (Forsberg 1993): the Temperature-Initiated Passive Cooling System (TIPACS). The characteristics of the TIPACS potentially match requirements for an improved reactor-cavity-cooling system (RCCS) for the modular high-temperature gas-cooled reactor (MHTGR). This report is an initial evaluation of the TIPACS for the MHTGR with a Rankines (steam) power conversion cycle. Limited evaluations were made of applying the TIPACS to MHTGRs with reactor pressure vessel temperatures up to 450 C. These temperatures may occur in designs of Brayton cycle (gas turbine) and process heat MHTGRs. The report is structured as follows. Section 2 describes the containment cooling issues associated with the MHTGR and the requirements for such a cooling system. Section 3 describes TIPACS in nonmathematical terms. Section 4 describes ...

1994-04-01

109

User's guide for the BNW-III optimization code for modular dry/wet-cooled power plants  

Energy Technology Data Exchange (ETDEWEB)

This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel power plant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, giving the user a great deal of flexibility.

1984-09-01

110

Spectroscopy of a narrow-line laser cooling transition in atomic dysprosium  

CERN Document Server

The laser cooling and trapping of ultracold neutral dysprosium has been recently demonstrated using the broad, open 421-nm cycling transition. Narrow-line magneto-optical trapping of Dy on longer wavelength transitions would enable the preparation of ultracold Dy samples suitable for loading optical dipole traps and subsequent evaporative cooling. We have identified the closed 741-nm cycling transition as a candidate for the narrow-line cooling of Dy. We present experimental data on the isotope shifts, the hyperfine constants A and B, and the decay rate of the 741-nm transition. In addition, we report a measurement of the 421-nm transition's linewidth, which agrees with previous measurements. We summarize the laser cooling characteristics of these transitions as well as other narrow cycling transitions that may prove useful for cooling Dy.

2010-01-01

111

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.

1981-01-01

112

Control of quench distortion for steel parts  

Energy Technology Data Exchange (ETDEWEB)

There are two types in quench distortion of steel parts: thermal distortion and transformation distortion. Quench distortion is caused mainly by uneven cooling rate of steel parts from Austenitising temperature. The rapid cooled side is lengthened (convex deformation); the slow cooled side is shortened (concave deformation). So, to control the quench distortion, it is necessary to regulate the cooling rate of steel parts during quenching. TWO COMPONENTS produce the quench distortion of steel parts: the thermal stress and transformation stress. Generally, the effect of the thermal stress on the quench distortion is stronger than the transformation stress. The quench distortion is caused by uneven cooling rate of the steel parts, from Austenitising temperature to Ms point and Ms-Mf range. So, to control the quench distortion, it is very important to regulate the ...

1996-12-31

113

Control of cooling during spray forming of bearing steel billets  

Energy Technology Data Exchange (ETDEWEB)

In an effort to minimize the distortion of bearing steel rings during the production process, 100Cr6 steel billets are spray formed with a unique cooling control system to control the cooling and solidification behavior of the deposits. Effects of heating around the deposits, gas cooling at the substrate bottom and the gas flow over the deposits are investigated both by numerical simulation and experiment. Porosity profiles and microstructures of spray formed bearing steel are examined and evaluated. The investigation results show that the thermal boundary conditions of the deposits play important roles on the cooling and solidification behavior of the deposits, especially at the deposit periphery. Porosity in the 100Cr6 bearing steel deposit can be reduced significantly with the special cooling control system.

2004-10-10

114

Chalk Point cooling tower project. Volume 2. Cooling tower drift dye tracer experiment, June 16 and 17, 1977. Final report 1 July 1976--30 June 1977  

Science.gov (United States)

A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aerosol deposition from other sources and to provide a data base for use in cooling tower salt loading and model validation. Prior to the experiment, laboratory tests showed that Rhodamine (WT) was inexpensive, safe and controllable when used as a drift dye tracer. Positive identification and separation of cooling tower drift can be made among other sources using a dye tracer.

1977-08-01

115

A Single Laser System for Ground State Cooling of 25-Mg+  

CERN Document Server

We present a single solid-state laser system to cool, coherently manipulate and detect $^{25}$Mg$^+$ ions. Coherent manipulation is accomplished by coupling two hyperfine ground state levels using a pair of far-detuned Raman laser beams. Resonant light for Doppler cooling and detection is derived from the same laser source by means of an electro-optic modulator, generating a sideband which is resonant with the atomic transition. We demonstrate ground-state cooling of one of the vibrational modes of the ion in the trap using resolved-sideband cooling. The cooling performance is studied and discussed by observing the temporal evolution of Raman-stimulated sideband transitions. The setup is a major simplification over existing state-of-the-art systems, typically involving up to three separate laser sources.

2010-01-01

116

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

117

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

119

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

121

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

122

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

123

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

124

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

125

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

126

The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core  

Energy Technology Data Exchange (ETDEWEB)

This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall ...

2006-07-15

127

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

128

User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code  

Science.gov (United States)

This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)

1977-01-01

129

Roof slab cooling device in a FBR type reactor  

International Nuclear Information System (INIS)

Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power ...

1986-05-16

130

RF tumor ablation with internally cooled electrodes and saline infusion: what is the optimal location of the saline infusion?  

UK PubMed Central (United Kingdom)

BackgroundRadiofrequency ablation (RFA) of tumors by means of internally cooled electrodes (ICE) combined with interstitial infusion of saline may improve clinical results. To date,...Full Text Available

131

Quality assurance requirements for packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants (Revision 1) - October 1976  

International Nuclear Information System (INIS)

This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.

132

Quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems  

International Nuclear Information System (INIS)

The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.

133

Legionella fairfieldensis sp. nov. isolated from cooling tower waters in Australia.  

UK PubMed Central (United Kingdom)

Three Legionella-like organisms were isolated from water from the cooling towers of two Australian institutions. The strains grew on buffered charcoal-yeast extract (BCYE) agar but not on BCYE agar...Full Text Available

1991-03-01

134

A comprehensive approach to cooling tower design  

Energy Technology Data Exchange (ETDEWEB)

In this paper, a mathematical model for a counterflow wet cooling tower is derived, which is based on one-dimensional heat and mass balance equations using the measured heat transfer coefficient. The balance equations are solved numerically to predict the temperature change of air and water, as well as the humidity as a function of the cooling tower high. Experimental measurements on two pilot-scale cooling towers were carried out in order to analyze the performance of different cooling tower filling materials. Also, the performance of other cooling tower elements, such as droplet separators and water spray nozzles, was investigated in the pilot experiments. The flow distribution, i.e. the velocity field, upstream to the filling material was predicted using the three-dimensional version of the computational fluid dynamics (CFD) code Fluent/UNS, version 4.2. The calculated flow ...

2001-06-01

135

A Multi-Method Process Evaluation for a Skin Cancer Prevention Diffusion Trial  

UK PubMed Central (United Kingdom)

This article describes process evaluation methods for the Pool Cool Diffusion Trial across four years. Pool Cool is a skin cancer prevention program that was...Full Text Available

2009-06-01

136
138

Natural convection cooling for offshore nuclear power plants  

International Nuclear Information System (INIS)

(May 1974). United States Klystra, CD Univ. of Florida, Gainesville v.

139

Natural convection cooling for offshore nuclear power plants  

International Nuclear Information System (INIS)

(1973). United States Kylstra, CD West Palm Beach, Florida, USA. 25 Apr 1973.

1973-04-25

140

MAY 1988. - NASA Technical Reports Server  

Science.gov (United States)

disciplinary methods were used to independently determine the aerodynamic loads, the thermal response, and strardural performance of the hydrogen cooled ...

141

MASER"'\\ - NASA Technical Report Server (NTRS)  

Science.gov (United States)

cooling system designed to reject waste heat producedwithin the alternatorand. To other equipment operatingat much lower tempera- ...

142

Integrated Reconfigurable Intelligent Systems (IRIS) for ...  

Science.gov (United States)

... They comprise of a power model for the representation of the electric system, a fluid model that represents the cooling fluid flow, three layers of ...

2009-10-31

143

Fuel cycle of reactor SVBR-100  

International Nuclear Information System (INIS)

... fast reactors fbr type reactors fuels liquid metal cooled reactors materials nuclear

144

Development of radial-flow type internally oil-cooled oil-filled cable  

Energy Technology Data Exchange (ETDEWEB)

A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.

1988-01-01

145

Behavior of the cooling towers as a function of the time  

International Nuclear Information System (INIS)

In the scope of the nuclear plants lifetime study, the behavior of the cooling towers is discussed. The main geometrical characteristics of the cooling towers in the French nuclear power plants, are presented. The surveyance program, the risks of accident, the research and development actions are considered. The results of the investigations of the cooling tower structure show that it is a multidiciplinary problem and needs the development of experimental and theoretical methods. Concerning the regenerators, the surveyance actions under operating conditions, the accelerated aging tests, and some aspects of the mechanical resistance, are underlined. It is shown that mainly the creep tests will allow the lifetime estimation of the materials developed for the regenerators.

1988-12-01

146

Advanced Gas Cooling Study for the Hospital at Davis ...  

Science.gov (United States)

... The performance at reduced condenser water temper- atures was assumed to be the same as that of the single-effect unit. ...

1999-01-01

147

Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.

1995-05-01

148

Natural Circulation Cooling Capability in the AHR  

International Nuclear Information System (INIS)

An AHR (Advanced HANARO Reactor) based on the HANARO has been conceptually developed for the future needs of research reactors. Generally, a natural convection cooling in nuclear installations is an ultimate heat removal mechanism as an inherent safety feature. This paper presents the preliminary thermal hydraulic characteristics and safety margins for a natural convection cooling in the AHR.

2007-10-01

149

Effect of cooling conditions during heat treatment on mechanical properties of titanium alloy VT3-1  

International Nuclear Information System (INIS)

Effect of cooling rates within the wide range (0.003-45 grad/s) on the complex of mechanical properties of (#alpha#-#beta#)-titanium alloy VT3-1 is studied in the process of heat treatment. Cooling conditions of semifinished product made of this alloy with a different structure providing optimum combination of strength, ductility fracture toughness, heat resistance, and endurance are determined.

150

Desiccant cooling: parametric energy study  

Energy Technology Data Exchange (ETDEWEB)

Desiccants have been used in many applications to provide dehumidification. This paper describes an application of desiccants which provide both dehumidification and sensible cooling, with little or no use of conventional vapour-compression refrigeration plant. Through a parametric study, the energy consumption and costs of a desiccant cooling system are compared with those of a conventional vapour-compression refrigeration-based air-conditioning system. (author)

1998-12-31

151

Cooling of nuclear power stations with high temperature reactors and helium turbine cycles  

International Nuclear Information System (INIS)

On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable ...

152

Cooling device for rotors of multistage axial steam turbines  

International Nuclear Information System (INIS)

The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).

153

Chalk Point Cooling Tower Project. Environmental Systems Corporation's FY77 final report, July 1, 1976--August 31, 1977. Volume II. Cooling Tower Drift Dye Tracer Experiment. [Dye tests of vapor plume dispersion in coastal regions  

Science.gov (United States)

Results are reported from dye tests of the dispersion of the vapor plume from the natural draft cooling tower of a fossil-fuel power plant located in the coastal region of Maryland.

1977-12-01

154

A study of the importance of occupancy to building cooling load in prediction by intelligent approach  

International Nuclear Information System (INIS)

Research highlights: #-># The building occupancy affecting the cooling load prediction is studied. #-># PENN model is adopted in this study for predicting the building cooling load. #-># Statistical approach is adopted to result a less prejudice prediction performance. #-># Results show that occupancy data can significantly improve the prediction. -- Abstract: Building cooling load prediction is one of the key factors in the success of energy-saving measures. Many computational models available in the industry today have been developed from either forward or inverse modeling approaches. However, most of these models require extensive computer resources and involve lengthy computation. This paper discusses the use of data-driven intelligent approaches, a probabilistic entropy-based neural (PENN) model to predict the cooling load of a building. Although it is common knowledge that the presence ...

2011-07-01

155

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

156

Using Floor Cooling as an Approach to improve the Thermal Environment in the Sleeping Area in an Open Pig House  

British Library Electronic Table of Contents (United Kingdom)

In order to provide pigs a comfortable sleeping area in hot weather, a floor cooling system was designed and applied to production buildings. Experiments were conducted to compare the floor temperatures and to observe the lying behaviour of pigs in the sleeping area of the buildings with and without floor cooling system. The results showed that, without the floor cooling system, the floor temperature was nearly the same as the air temperature in the open pig house. With the floor cooling system, the floor temperature of the sleeping area was controlled at 22-26degreeC, even though the air temperature was as high as 34degreeC, which improved the comfort of the pigs in the sleeping area. The pig lying behaviour was greatly affected by the floor temperature. More than 85% of the pigs were lyi...

2006-01-01

157

Thermal-hydraulic performance of the GETR emergency cooling system: experimental and analytical considerations  

International Nuclear Information System (INIS)

The General Electric Test Reactor emergency cooling system performance was tested by intentionally scramming the reactor and then terminating the power to the primary pump. Certain transient thermal-hydraulic data were obtained preceding and during the established natural convection cooling loop composed of the upward flow through the core and the downward flow through the pool. An analysis was performed to permit the data to be extrapolated to obtain distributed fuel element flow rates and bulk temperature rises during the established cooling loop. The earliest time for the quasi-steady natural cooling loop to develop is about 2.5 min following scram. The cladding hot-spot temperature does not exceed the local saturation temperature after quasi-steady flow is established. Data are presented to assist in the modeling of the GETR natural convection loop. Semi-empirical relationships for friction factor ...

158

The effect of thermal pretreatment on the structure and creep behaviour of the alloy 800 H. Zum Einfluss der thermischen Vorbehandlung auf Struktur und Kriechverhalten des Werkstoffs Alloy 800 H  

Energy Technology Data Exchange (ETDEWEB)

Different cooling speeds after previous solution annealing at 1130deg C for 0.5 hour were simulated in laboratory experiments. The following conditions were examined: (1) Direct water quenching, (2) cooling in air for 0.5 min to 950deg C/water quenching, (3) cooling in air for 1.5 min to 750deg C/water quenching, (4) cooling in furnace for 5 min to 750deg C/water quenching. The results of the investigations have shown that a variation of the cooling conditions causes considerable changes in the creep behaviour. (orig.).

1987-01-01

159

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

160

Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki  

Energy Technology Data Exchange (ETDEWEB)

A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)

2000-01-10

161

High thermal load receiving heat plate  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.).

1993-09-28

162

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an ...

163

Construction progress of the cooling & ventilation in the LHC project  

CERN Document Server

After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.

2002-01-01

164

Construction Progress of the Cooling and Ventilation in the LHC Project  

CERN Document Server

The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. ...

2001-01-01

165

A comparative design study of PB-BI cooled reactor cores with forced and natural convection cooling  

International Nuclear Information System (INIS)

A comparative core design study is performed on Pb-Bi cooled reactors with forced and natural convection (FC and NC) cooling. Major interests of the study are core performance and core safety features. The designed core concepts with nitride fuel achieve reasonable breeding capability. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features to withstand unprotected events due to negative reactivity feedback by Doppler effect, control rod drive line expansion, etc. These results lead to a conclusion that both of concepts have possible capability as one of future promising core concepts. A FC cooling core concept has more advantage if fuel recycle viewpoint is emphasized. (author)

2003-04-20

166

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

168

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

169

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

170

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

171

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

172

Parametric Resonance Ionization Cooling and Reverse Emittance Exchange for Muon Collider  

Energy Technology Data Exchange (ETDEWEB)

Two methods to cool muon beams deeply below the limit conventionally established for the ionization cooling are proposed. In Phase Ionization Cooling (PIC), the beam is focused at wedge absorber plates each half of particle oscillation period by imposing a weak parametric resonance along the beam path. The resonance growth of particle amplitude is surmounted by the ionization cooling. At optimum, such arrangement results in reduction of each of two transverse emittances by an order of value in addition to the preceding 6D ionization cooling. Next, resonance focusing and transverse cooling can be continued in the regime of a fast Reverse Emittance Exchange (REMEX). Here, the sign of the absorber wedge is opposite to PIC while the dispersion increased. REMEX to be accompanied by the bunch lengthening and acceleration in order to maintain the relative energy spread ...

2005-09-18

173

Nomographs for H[sub 2]O-LiBr absorption-panel cooling systems  

Energy Technology Data Exchange (ETDEWEB)

Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup o]C; thus, the system may be operated on solar energy. ...

1992-11-01

174

Thermal Modeling and Performance Analysis of Interim Dry Storage and Geologic Disposal Facilities for Spent Nuclear Fuel  

Science.gov (United States)

Thermal models are constructed and analyses are performed of aluminum-based spent nuclear fuel (Al-SNF) in interim dry storage and geologic disposal configurations. Two models are developed, referred to as the interim storage model and the codisposal waste package (WP) model. Time-dependent source terms of Al-SNF forms and the defense high-level waste (DHLW) canisters are also developed for thermal performance analysis of the geologic codisposal WP.The interim storage model is a three-dimensional conduction-convection conjugate model to investigate the natural convection cooling of a sealed dry storage canister with vertical orientation in a dry storage vault. The analysis is made for various decay heat sources (equivalent to 25 to 35 kW/m{sup 3}) using various boundary conditions around the canister wall and with backfilled nitrogen or helium gas. Based on the data obtained from the Savannah River Site experimental work and available from the literature, an ...

2000-07-15

175

Short rotation coppice harvesting: an evaluation of the Salix Maskiner Bender III  

Energy Technology Data Exchange (ETDEWEB)

Version III of the Salix Maskiner ``Bender`` coppice harvester was used to successfully harvest 11.2 hectares of short rotation poplar and willow coppice in February 1997. On a wide range of typical UK crop and site conditions, the Swedish harvester was shown to have productivity rates ranging from 4.28 to 7.97 odt/smh. Based on a total system cost of Pound 81.26 per scheduled machine hour, the Bender III is able to produce wood chip for between Pound 10.20 and pound 18.97 per dry tonne. The variation in machine productivity is dependent on crop productivity and working method, emphasising the importance of site design in optimising system efficiency. In willow crops the wood chip produced by the Bender III contained a significant amount of material greater than 75mm in length. The bulk of the chips however, fell into the 5-45mm category with only a very limited amount of fine materials less than 5mm in length. The chips from poplar crops were more uniform with the majority of material ...

1997-12-31

176

Review of passive heat transfer augmentation techniques  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive techniques of heat transfer augmentation have been reported. ...

2004-12-01

177

Properties of SiC/SiC joining s and coatings for fusion  

International Nuclear Information System (INIS)

Full text of publication follows: As SiCf/SiC composites are very low activation materials, their use as structural material for the reactor blanket and first wall components appears essential to demonstrate the potential of D-T fusion power reactor. Positive features of SiCf/SiC are their high performances at elevated operating temperature and the ability to produce a specific component. Critical issues of SiCf/SiC are the mechanical properties, radiation stability and, with regard to technological issues, their hermeticity and joining processes. Improvement of joining processes for SiC/SiC components is also needed. Recently, several blanket designs have been studied: the TAURO blanket concept in the European Union, the ARIESAT concept in the US and the DREAM concept in Japan. In those reactors, hermetic SiCf/SiC or self-sealing coatings are mandatory. The basic idea of self sealing concept is to manufacture a coating with specific requirements (CTE and ...

2007-12-10

178

Magnetic braking of collapsing interstellar clouds  

International Nuclear Information System (INIS)

The purpose of this investigation is to show that resource to anisotropic compression along a magnetic field is not a necessary condition for star formation within large collapsing interstellar gas clouds. Although such a scenario would certainly eliminate the magnetic field and angular momentum problems associated with isotropically collapsing clouds, it is believed there is sufficient observational theoretical evidence to warrant the present study of magnetically braked, isotropically collapsing gas clouds. It is not attempted to disprove the hypothesis of anisotropic compression, but to offer instead, a reasonable alternative. Angular momentum transfer from magnetically braked, cool interstellar gas clouds of 10"2, 10"3 and 10"4 times the mass of the sun is examined. Magnetic torques acting on a contracting, rotating cloud, permeated by a frozen-in magnetic field coupling the cloud to the galactic field of the surrounding interstellar medium, produce kinks in ...

179

International Energy Agency (IEA) Small Solar Power Systems (SSPS) sodium cavity and external receiver performance comparison  

Energy Technology Data Exchange (ETDEWEB)

This report uses experimental data to compare the performance of two sodium cooled solar central receivers operated at the International Energy Agency Small Solar Power Systems project near Almeria, Spain. Performance includes point-in-time steady state efficiency, average efficiency, start-up time, and operation time. Point-in-time steady state efficiency calculations were based on the statistical method of least squares using receiver incident and absorbed powers. One receiver, a cavity type, showed a peak steady state receiver efficiency of 87% +- 5% and an average efficiency of about 67%. The other receiver, an external ''billboard'' type, had a peak steady state receiver efficiency of 96% +- 4% and an average efficiency of about 79%. The original design peak steady state efficiency predictions for both receivers were within the experimentally determined 95% probability interval. Thermal loss test data were evaluated for the ...

1987-10-01

180

Effects of field orientation during 700-MHz radiofrequency irradiation of rats  

Energy Technology Data Exchange (ETDEWEB)

Ketamine-anesthetized Sprague-Dawley rats were exposed to far-field 700-MHz continuous-wave radiofrequency radiation (RFR) in both E and H orientations. Irradiation was conducted at whole-body average specific absorption rates (SARs) of 9.2 and 13.0 W/kg (E and H, respectively) that resulted in approximately equivalent colonic specific heating rates (SHRs). Exposures were performed to repeatedly increase colonic temperature by 1 deg C (38.5 to 39.5 deg C). Tympanic, tail, left and right subcutaneous (toward and away from RFR source), and colonic temperatures, arterial blood pressure, and respiratory rate were continuously recorded. In spite of equivalent colonic SHRs and the reduced E-orientation average SAR, the right subcutaneous, tympanic, and tail SARs, SHRs and absolute temperature increases were significantly greater in E than in H orientation. The cooling rate at all monitoring sites was also significantly greater in E than in H ...

1989-01-01

181

A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP  

International Nuclear Information System (INIS)

Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. Confusions for the inspected tubes may occur from deflection of the manipulators. To reduce the deflections ...

2010-10-01

184

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

192

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

195

Calculation of current-carrying capacity of forced cooled high-voltage cable lines  

Energy Technology Data Exchange (ETDEWEB)

The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. The permissible current is calculated once ...

1982-01-01

197

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...

198

Radiation Therapy in Treating Patients With Prostate Cancer  

Science.gov (United States)

Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility

2011-09-13

200

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

202

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

203

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

204

Production of ultra high strength steels by turbulent water cooling equipment (TWICE); Production d'aciers haute resistance par un dispositif de refroidissement a turbulence controlee  

Energy Technology Data Exchange (ETDEWEB)

A new industrial process allowing to reach very high cooling rates in the cooling section after soaking of a continuous annealing line for steel sheets is presented. This process constitutes the successful conclusion of a long term research programme, jointly carried out at CRM and Arcelor Cockerill-Sambre for three years, including laboratory experiments, pilot scale trials and several industrial campaigns. It is running on from developments performed in the framework of the HOWAQ (Hot Water Quench) process. The process successively combines a moderate cooling step (600 deg C/s for 0.8 mm thick strips), in boiling water, and a faster cooling step (above 700 deg C/s), by impinging turbulent cold water in a box. Its main features are simplicity, resulting from advanced developments, soundness, flexibility and cooling homogeneity. As treated steel products are characterized by ...

2003-08-01

205

Low-temperature brown rice storage by using renewable energy from snow  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study that was conducted in Japan to determine whether renewable energy generated from snow can be used to replace the cooling system and electricity used for cooling a rice storehouse that maintained the grain temperature below 15 degrees C. However, the low-temperature storage system required a cooling system and electricity to cool rice in summer. In this study, a snow pile using 890 t of snow was made at the beginning of March next to the rice storehouse. The shape of the snow pile was a trapezium, 17 x 23 m at the bottom and 4 x 10 m at the top and 5 m in height. The snow pile was covered with 200 to 300 mm of wood chips to act as an insulation layer. Approximately 27 per cent of the energy for cooling the rice storehouse could be replaced by using the snow pile in summer. The quality of stored rice was almost similar to that of freshly harvested rice. ...

2010-07-01

206

Influence of suspended solids on pitting corrosion of carbon steel in cooling water. Tansoko no koshoku ni oyobosu reikyaku suichu no kendaku busshitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion enlarging the rust due to its deposition near the ...

1993-08-15

207

Heat-driven liquid metal cooling device for the thermal management of a computer chip  

International Nuclear Information System (INIS)

The tremendous heat generated in a computer chip or very large scale integrated circuit raises many challenging issues to be solved. Recently, liquid metal with a low melting point was established as the most conductive coolant for efficiently cooling the computer chip. Here, by making full use of the double merits of the liquid metal, i.e. superior heat transfer performance and electromagnetically drivable ability, we demonstrate for the first time the liquid-cooling concept for the thermal management of a computer chip using waste heat to power the thermoelectric generator (TEG) and thus the flow of the liquid metal. Such a device consumes no external net energy, which warrants it a self-supporting and completely silent liquid-cooling module. Experiments on devices driven by one or two stage TEGs indicate that a dramatic temperature drop on the simulating chip has been realized without the aid of any fans. The higher the ...

2007-08-07

208

Comparisons between experimental results and numerical simulations for the Sonaco sodium natural convection experiments  

International Nuclear Information System (INIS)

The SONACO experiments are conducted on an electrically heated 37-pin rod bundle, immersed in liquid sodium and contained within a hexagonal wrapper. The rig was designed to investigate natural convection cooling for a geometry representative of fast reactor fuel assemblies. Heat can be removed from the test section in several ways, but in this paper only the axial cooling mode is examined. Above the heated bundle is a plenum, at the top of which is a cooling coil containing a separate, forced sodium flow. Heat transfer from the bundle to this cooling coil is effected by means of buoyancy driven circulatory flow in the sodium, and in the axial cooling mode almost all the heat is removed by the coil. This mode is intended to simulate the natural convection cooling of a blocked fuel assembly by way of thermosyphon coupling to the inner pool. In this paper ...

209

Survey of Radiation Protection Education and Training in Finland in 2003  

Energy Technology Data Exchange (ETDEWEB)

The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...

2004-07-01

210

Strong Convergence towards homogeneous cooling states for dissipative Maxwell models  

CERN Document Server

We show the propagation of regularity, uniformly in time, for the scaled solutions of the inelastic Maxwell model for small inelasticity. This result together with the weak convergence towards the homogenous cooling state present in the literature implies the strong convergence in Sobolev norms and in the $L^1$ norm towards it depending on the regularity of the initial data. The strategy of the proof is based on a precise control of the growth of the Fisher information for the inelastic Boltzmann equation. Moreover, as an application we obtain a bound in the $L^1$ distance between the homogeneous cooling state and the corresponding Maxwellian distribution vanishing as the inelasticity goes to zero.

2008-01-01

211

Steady-state neutronic investigations to the accident of water ingress in systems with pebble-bed high-temperature gas-cooled reactor fuel  

Energy Technology Data Exchange (ETDEWEB)

For light water reactors, loss of coolant is an important point in safety analysis, whereas for gas-cooled reactors the ingress of water into the core region is an incident of safety relevance. The applicability of the computer code system GAMTEREX to pebble beds of spherical high-temperature gas-cooled reactor fuel elements with simulated water ingress is verified by experiment. The measurements were performed at a Siemens-Argonaut reactor, using its ring core as a driver zone for a pebble-bed core in the center of the reactor.

1987-09-01

212

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

213

Pressure drop and heat transfer in gas-cooled rod bundles  

International Nuclear Information System (INIS)

Extensive experimental and analytical investigations of fluid flow and heat transfer in gas-cooled rod bundles have been carried out. Different bundle geometries with partially or fully roughened rod surfaces were tested in a carbon dioxide loop. An advanced and comprehensive measuring control and instrumentation are important design features of this experiment. Comprehensive thermal hydraulic subchannel analysis computer codes have been developed in order to assist fuel element design calculation for gas-cooled reactors. The experiments, codes and their verification procedure are described and the results of comparisons between measured and calculated pressure and temperature distributions are given. (orig.).

214

Neutron star evolution with internal heating  

Energy Technology Data Exchange (ETDEWEB)

The thermal evolution predicted by current models of the superfluid-crust interaction is noted to differ substantially from the thermal evolution predicted by models without internal heating as well as previous models of heating. Heating rates approaching the maximum predicted by current models enhance the photon luminosity of the star in the neutrino cooling era, and dramatically alter the thermal evolution in the photon cooling era. Standard cooling models are consistent with current pulsar temperature estimates and upper limits, except those for the Vela pulsar, which are lower than predicted. 77 refs.

1989-11-01

215

Mixed structures in continuously cooled low-carbon automotive steels  

Energy Technology Data Exchange (ETDEWEB)

Mixed microstructures have been studied in low- carbon microalloyed steels suitable for automotive applications, after continuous cooling from the hot-rolled condition. Microstructural features such as polygonal ferrite, bainitic and acicular ferrite and microphase constituent are identified using transmission electron microscopy. The influence of these mixed structures on the tensile strength, impact toughness and fracture behaviour is examined. It is found that improvements in impact toughness as compared with microalloyed medium- carbon ferrite/pearlite steels can be achieved from these predominantly acicular structures developed by controlling alloy composition and continuous cooling of these lower carbon steels. (orig.).

1993-11-01

216

Mixed structures in continuously cooled low-carbon automotive steels  

International Nuclear Information System (INIS)

Mixed microstructures have been studied in low- carbon microalloyed steels suitable for automotive applications, after continuous cooling from the hot-rolled condition. Microstructural features such as polygonal ferrite, bainitic and acicular ferrite and microphase constituent are identified using transmission electron microscopy. The influence of these mixed structures on the tensile strength, impact toughness and fracture behaviour is examined. It is found that improvements in impact toughness as compared with microalloyed medium- carbon ferrite/pearlite steels can be achieved from these predominantly acicular structures developed by controlling alloy composition and continuous cooling of these lower carbon steels. (orig.).

1993-06-01

217

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

218

HPOF transmission-system economic-evaluation program. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.

1983-01-01

219

Experimental 1 kW 20 cell PEFC stack  

Energy Technology Data Exchange (ETDEWEB)

A 20-cell PEFC stack was designed and built. Resin impregnated graphite was used as bipolar plate material. The air cooling of the stack was optimized by introducing high surface structures into the open space of the cooling plates. At {eta} (H{sub 2} LHV) = 0.5 a power of 880 W was obtained under conditions of low gas-pressures of 1.15 bar{sub a}. The auxiliary power for process air supply and cooling at 880 W power is less than 7% of the power output, indicating that the described system may be operated at a high efficiency. (author) 5 figs., 2 refs.

1999-08-01

220

Enhanced LMR core cooling utilizing passive vortex devices  

International Nuclear Information System (INIS)

This paper reports several design options for improved passive circulation flow investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.

1988-05-01

221

Enhanced LMR [liquid metal reactors] core cooling utilizing passive vortex devices  

International Nuclear Information System (INIS)

Several design options for improved passive circulation flow have been investigated for use in small, modular liquid metal cooled reactors (LMRs). The purpose is to enhance the transition to natural convection cooling following loss of forced circulation flow, reducing thermal transients experienced by the fuel and possibly eliminating the need for emergency pony-motor flow. Design details to minimize pressure drops may also enhance maximum equilibrium power levels possible under natural circulation only.

1988-05-01

222

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

223

Convection in the cavity between two rollers: The effect of thermal boundary conditions  

Energy Technology Data Exchange (ETDEWEB)

In this study the authors examine the convective cooling provided by fluid trapped in the cavity between two consecutive rollers in a roller bearing. In order to calculate the steady-state temperature of the roller, the designer must know nor only the rolling-contact heat input received by the roller but also the convection cooling effect of the surrounding fluid. Until recently, this lateral convection cooling effect was modeled by assuming a certain (constant) heat transfer coefficient h at the roller surface, and then calculating the steady-state temperature distribution around the roller.

1991-02-01

224

Chalk Point Cooling Tower Project. Environmental systems corporation's comprehensive project status report for FY75, July 1, 1974--October 1, 1975. [Environmental effects of natural draft cooling towers of oil-fired power plant  

Science.gov (United States)

Results are reported from initial characterization tests on the environmental effects of the natural draft cooling tower of the Chalk Point Unit 3 oil-fired power plant located on the shore of Chesapeake Bay. Data are included on updraft air velocity, plume drift, and sea salt deposition in relation to meteorological conditions.

1976-05-01

225

Assessment of cooling effects on extending the maximum operating time for the Syrian Miniature Neutron Source Reactor  

International Nuclear Information System (INIS)

Various schemes of cooling have been investigated for the purpose of assessing potential benefits on the operational characteristics of the Syrian MNSR reactor. A detailed thermal hydraulic model for the analysis of MNSR has been developed. The analysis shows that an auxiliary cooling system, installed in the pool which surrounds the lower section of the reactor vessel, will significantly offset the consumption of excess reactivity due to the negative reactivity temperature coefficient, Hence, the maximum operating time of the reactor is extended. Compared with experimental data, the suggested model proves to be valid for the analysis of MNSR behavior under both steady state and transient conditions. (author)

2007-01-01

226

Weather - Hanford Site  

Science.gov (United States)

to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...

2011-10-01

227

Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems  

Energy Technology Data Exchange (ETDEWEB)

In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

2006-03-01

228

Traveling Wave RF Systems for Helical Cooling Channels  

Energy Technology Data Exchange (ETDEWEB)

The great advantage of the helical ionization cooling channel (HCC) is its compact structure that enables the fast cooling of muon beam 6-dimensional phase space. This compact aspect requires a high average RF gradient, with few places that do not have cavities. Also, the muon beam is diffuse and requires an RF system with large transverse and longitudinal acceptance. A traveling wave system can address these requirements. First, the number of RF power coupling ports can be significantly reduced compared with our previous pillbox concept. Secondly, by adding a nose on the cell iris, the presence of thin metal foils traversed by the muons can possibly be avoided. We show simulations of the cooling performance of a traveling wave RF system in a HCC, including cavity geometries with inter-cell RF power couplers needed for power propagation.

2009-05-01

229

Thermo-economic analysis of solar powered adsorption heat pump  

British Library Electronic Table of Contents (United Kingdom)

The economic feasibility of the residential solar thermal (ST) cooling system designed in the companion article [1] is ascertained by comparing it with a solar electric (SE) cooling system, and also with the baseline (i.e., control case), a grid dependent, highest efficiency COPC=5.66 heat pump. The economic scenario is analyzed for 24 cities across the southern USA, south of the 37degreeN. The SE cooling system provides lifecycle (20 year) savings to the homeowner only where electric rates are high and it is heavily subsidized. The overall societal effect (sum of taxpayer funded rebate and homeowner savings) is actually an increased cost everywhere except the California Central Valley, where the net savings is $1500. In the same valley, The ST cooling system provides greater lifecycle sav...

2007-01-01

230

Thermal control of electric vehicle batteries  

Energy Technology Data Exchange (ETDEWEB)

The need to operate electric vehicles in warm, summer conditions and also provide for long periods of standby in cold climates is a challenging problem for any battery system. All advanced batteries of high specific energy require active cooling systems because adiabatic heating will raise the temperature to a level that is deleterious to cycle life. This cooling requires efficient paths for escape of heat to cooled surfaces; cooling the exterior of modules is insufficient. If a battery is heated by its own energy, and insulated to withstand exposure to a cold climate, only vacuum insulation will afford an appreciable reduction (>10{degrees}C) in the ambient temperature that can be tolerated. Standard insulations are of little use for this purpose because the heat loss rate causes too high a drain on the battery energy even for near-ambient temperature batteries.

1995-07-01

231

The Goddard Library - Goddard Projects Directory - NASA  

Science.gov (United States)

Oct 2, 2007 ... Other payloads included the Orbiter Experiments Autonomous Supporting Instrumentation System-1 (OASIS-1), a cooling system designed for ...

232

Solar-powered cooling systems: Technical and economic analysis on industrial refrigeration and air-conditioning applications  

British Library Electronic Table of Contents (United Kingdom)

In the last years, the growing demand for air conditioning has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the technologies which allows to obtain, by using the renewable solar source, an important energy saving compared to traditional air conditioning plants. The paper describes different technical installations for solar cooling, their way of operation, advantages and limits. The objective of the present study has been to analyze the technical and economic feasibility of solar absorption cooling systems, designed for two different application fields: industrial refrigeration and air conditioning. The possibility to replace or integrate the existing plants is studied, by considering the refrigeration requirements of a company, whic...

2009-01-01

233

RESEARCH MEMORANDUM - NASA Technical Report Server (NTRS)  

Science.gov (United States)

lytical Comparison of Turbine-Blade Cooling System Designed for a. TurboJet Engine Operat- at Supersonic Speed and Altitude. I1 -. Air-C~Oling Systems. ...

235

Numerical simulations of nucleate boiling in impinging jets: Applications in power electronics cooling  

Energy Technology Data Exchange (ETDEWEB)

Boiling jet impingement cooling is currently being explored to cool power electronics components. In hybrid vehicles, inverters are used for DC-AC conversion. These inverters involve a number of insulated-gate bipolar transistors (IGBTs), which are used as on/off switches. The heat dissipated in these transistors can result in heat fluxes of up to 200 W/cm{sup 2}, which makes the thermal management problem quite important. In this paper, turbulent jet impingement involving nucleate boiling is explored numerically. The framework for these computations is the CFD code FLUENT. For nucleate boiling, the Eulerian multiphase model is used. The numerical results for boiling water and R113 jets (submerged) are validated against existing experimental data in the literature. Some representative IGBT package simulations that use R134a as the cooling fluid are also presented. (author)

2008-01-15

236

Liquid level control system of fast reactor secondary cooling system  

International Nuclear Information System (INIS)

Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).

237

Introduction & Overview to Symposium 240: Binary Stars as ...  

Science.gov (United States)

... CVn) consisting of a dM3 star and a cool white dwarf that must have evolved through the common-envelope stage of binary star evolution (Else van ...

2011-05-14

238

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

239

Hanford Speakers Bureau - Hanford Site  

Science.gov (United States)

to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...

2011-10-02

240

FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...  

Science.gov (United States)

was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...

241

Cryogenic trick for enhanced cooling using liquid nitrogen  

International Nuclear Information System (INIS)

The thermal transpiration method has been employed to replace the temperature of liquid nitrogen by #approx#12 K. This is done by bubbling He (g) through the liquid nitrogen.

1993-01-01

242

Collisional Cooling of Negative Ion Beams  

Science.gov (United States)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

243

Collisional Cooling of Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Investigations have been conducted to determine the feasibility of using collisional cooling for reducing the energy spreads and, consequently, the emittances of negative-ion beams. We have designed a gas-filled RF-quadrupole ion cooler equipped with provisions for retarding energetic negative ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to high energies after the cooling process. The device has been used to cool O{sup -} and F{sup -} ion beams with initial energy spreads, {Delta}E > 10 eV to final energy spreads, {Delta}E {approx} 2 eV FWHM. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that electron detachment is the major loss mechanism for negative ions.

2001-06-29

244

Alpha/Beta Heat Treatment of a Titanium Alloy with a Non ...  

Science.gov (United States)

... transformed at 705°C. The cooling rate and temperature dependence of matrix decomposition for Ti6242 was thus similar to that for Ti64 x [9]. ...

2006-08-01

245

The benefits of low level radiation  

Energy Technology Data Exchange (ETDEWEB)

The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).

1997-06-01

246

Stimulated radiation of high - current relativistic electron beams  

International Nuclear Information System (INIS)

The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.

1987-01-01

247

Radiation protection. A guide for scientists and physicians  

International Nuclear Information System (INIS)

This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...

248

Biological effects of electromagnetic radiation in the microwave range  

Energy Technology Data Exchange (ETDEWEB)

The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...

1980-01-01

249

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and ...

1346-01-01

250

[The indicators of biological age and accelerated aging in liquidators of the consequences of radiation emergency].  

Science.gov (United States)

The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627

2011-01-01

251

The THz Radiation from Undulator  

Science.gov (United States)

The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.

2010-02-03

252

Study of emission of Cerenkov radiation by tachyons  

Energy Technology Data Exchange (ETDEWEB)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.

1983-01-01

253

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

254

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

255

Potential Hazards from Neutrino Radiation at Muon Colliders  

CERN Document Server

High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.

1999-01-01

256

Model of quantum noise of shadow radiation images  

International Nuclear Information System (INIS)

Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems

257

Coherent oscillator radiation  

International Nuclear Information System (INIS)

Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.

1982-04-01

258

System behavior after a loss of electric power in HANARO  

International Nuclear Information System (INIS)

A LOss of Electric Power(LOEP) experiment was conducted after a 30MW full power operation as one of the reactor performance tests to verify the design characteristics of the HANARO. The objective of LOEP test was to investigate the integral behaviors of the system and the components as well as the cooling characteristics when the electric power was lost unexpectedly. Through the test, it was confirmed that the residual heat from the core was safely removed by the natural convection cooling and the assistant power systems operated normally

2005-04-11

259

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

260

SUSTAINABLE H/C SYSTEMS FOR CHICKEN FARMS IN SYRIA  

Energy Technology Data Exchange (ETDEWEB)

Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these plants. The chicken farms have no cooling systems since ...

2008-09-30

261

Rural residential application of geothermal heat pump. Final grant report  

Energy Technology Data Exchange (ETDEWEB)

A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)

1982-07-30

262

Regional spinal cord blood flow during local cooling  

Energy Technology Data Exchange (ETDEWEB)

We used the tissue distribution of ({sup 14}C)butanol to quantitate regional blood flow in the spinal cord (RSCBF) of pentobarbital-anesthetized, normothermic rats in which segmental local cooling pentobarbital-anesthetized, normothermic rats in which segmental local cooling of the spinal cord (to 25-28{degrees}C) at vertebral levels C4-C6 (n = 6) or T13-L1 (n = 6) was induced. Thirty minutes later, blood flow measurements were made at seven levels of the spinal cord and in the sciatic nerve trunks and biceps femoris muscles. Sham-cooled rats served as controls (n = 12). In control rats, RSCBF varied between 41.5 +/- 2.4 and 65.1 +/- 3.2 ml.min-1.100 g-1. Local cooling of the C4-C6 cord segment reduced RSCBF by 32%, from 65.1 +/- 3.2 to 44.4 +/- 3.5 ml.min-1.100 g-1 (P less than 0.01). Tissue vascular resistance (R) in the cooled C4-C6 segment was elevated versus control. There were ...

1990-06-01

263

Numerical simulation of the unsteady and turbulent flow in a high-pressure turbine stage; Simulation numerique de l'ecoulement instationnaire et turbulent dans un etage de turbine haute pression  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study concerns the use of numerical methods for the resolution of the Reynolds Averaged Navier Stokes equations adapted to the simulation of the cooling of the trailing edge of a stator in a high pressure turbine. These methods, based on the elsA solver developed at ONERA, use a four steps Runge Kutta time discretization scheme and a Jameson centered space discretization scheme. The scheme is applied through a finite volume approach on control volume centered on the cells of a multi-block structured mesh. Turbulence is simulated either through the algebraic Michel model, or through the one-transport-equation Spalart-Allmaras model, or through the two-transport-equations k 1, k {omega} and k {epsilon} models, and through ASM model. A simulation of the flow in a bidimensional stator, without cooling, is carried out. The cooling, which is realized with trailing edge slots, is then simulated on a bidimensional ...

2004-09-15

264

MR-6 type fuel elements cooling in natural convection conditions after the reactor shut down  

International Nuclear Information System (INIS)

Natural cooling conditions of the nuclear fuel in the channel type reactor after its shut down are commonly determined with relatively high uncertainty. This is not only to he lack of adequate measurements of thermal parameters i.e. the residual power generation, the coolant flow and temperatures, but also due to indeterminate model of convection mechanism. The numerical simulation of natural convection in multitube fuel assembly in the fuel channel leads to various convection modes including evidently chaotic behaviour. To determine the real cooling conditions in the MARIA research reactor a series of experiments has been performed with fuel assembly equipped with a set of thermocouples. After some forced cooling period (the shortest was half an hour after the reactor shut down) the reactor was left with the only natural convection. Two completely different cooling modes have been observed. The MARIA ...

2002-03-17

265

Local analysis of three-dimensional air cooled condenser using a two-phase flow diagram  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the development and application of an analytical method for the performance prediction of air cooled condensers. A local analysis is employed in which the condenser is considered as a matrix of small basic heat transfer modules. For each element, local film coefficients for both the air and the condensing fluid are determined according to the existing local conditions, including the two-phase flow regime. The paper considers an application of the method to heat pump condensing.

1983-07-01

266

Liquid metal cooled fast breeder reactor comprising electromagnetic braking systems of the coolant flow  

International Nuclear Information System (INIS)

The liquid-metal-cooled fast breeder reactor presented includes a fuel assembly made up of several long sub-assemblies rising side by side. Each of the sub-assemblies of an external area of the fuel assembly comprises an electromagnetic braking system for regulating the flow of coolant in the sub-assembly, the magnetic fields of the braking systems being temperature sensitive.

267

Investigation on natural convection decay heat removal for the EFR: Status of the program  

International Nuclear Information System (INIS)

The European Research and Development Program on decay heat removal by natural convection for the European Fast Reactor (EFR) covers the calculational methods and the model experiments performed for code validation. The studies concentrate on important physical effects of the cooling modes within the primary system and the direct reactor cooling circuits and include fundamental tests as well as reactor experiments. (author)

1991-11-05

268

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat pipe, in which the return of the condensate to the ...

2004-07-01

269

Dry storage concepts and their thermodynamic layout  

International Nuclear Information System (INIS)

The two favourable dry storage concepts being under consideration in the Federal Republic of Germany are presented and the physical behaviour or natural convection cooling with air is explained. With the three examples cask store, vault storage horizontally and vertically arranged the main thermodynamical design parameters and their influence on the efficiency of the cooling system and on the temperature distribution inside the store and of the stored material are discussed. Moreover, the importance of the fulfilment and the harmony of all safety criteria and the difficulties while to do so are carried out especially with the vault store.

270

Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report  

Energy Technology Data Exchange (ETDEWEB)

This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as ...

1984-07-01

271

Combined-cycle cogen plant a successful good neighbor  

Energy Technology Data Exchange (ETDEWEB)

This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.

1993-04-01

272

Chalk Point Cooling Tower Project: Cooling Tower Effects on Crops and Soils. Preoperational Report, Appendix.  

Science.gov (United States)

This report contains data collected on a monthly basis over the period April, 1973 - April, 1975 for dustfall particulates, sodium and chloride and SO2 levels obtained from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO and ...

1976-01-01

273

Chalk Point Cooling Tower Project: Cooling Tower Effects on Crops and Soils. Post Operational Report No. 2.  

Science.gov (United States)

This report contains a summary of monthly dustfall, SO2, rainfall, crops and soils information obtained over the period May, 1976 to March, 1977 from 12 monitoring sites near the Chalk Point Generating Station operated by PEPCO which is located 65 km sout...

1977-01-01

274

Thermal analysis of spent fuel in shuttle station during dry transfer under abnormal cooling conditions for TAPS - 4  

International Nuclear Information System (INIS)

A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle ...

2006-11-13

275

System Analysis for Decay Heat Removal in Lead-Bismuth Cooled Natural Circulated Reactors  

Science.gov (United States)

Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heat removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 Centigrade, because the buoyancy force in ...

2002-07-01

276

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

Energy Technology Data Exchange (ETDEWEB)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...

1995-03-01

277

Studies on magnetohydrodynamic flow characteristics and heat transfer of liquid metal two-phase flow cooling systems for a magnetically confined fusion reactor  

International Nuclear Information System (INIS)

Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a vertical circular ...

278

Status of he-cooled divertor development (PPCS subtask TW4-TRP-001-D2)  

International Nuclear Information System (INIS)

Within the framework of the EU power plant conceptual study (PPCS), helium-cooled modular divertor concepts have been investigated in detail at the Forschungszentrum Karlsruhe during the past few years. The first conceptual design proposed was based on convective cooling with the use of flow promoters in the form of pin and/or slot arrays (HEMP/HEMS) to increase the cooling surface and, hence, enhance the heat transfer capacity. While continuing the design optimisation, an advanced multiple-jet design (HEMJ) was introduced, which is based on direct jet-to-wall impinging cooling and offers advantages in terms of simple construction and manufacturing. Main emphasis of the 2004 work program (TW4-TRP-001) lay on experiments for the concepts HEMJ and HEMS, which were mainly performed at the Efremov Institute in St. Petersburg, Russia. For experiment preparation, detailed test programs were worked out and ...

279

Performance characteristics of a natural circulation cooling/latent heat storage system  

Energy Technology Data Exchange (ETDEWEB)

A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As a result of a 48 hour simulation experiment with load ...

1987-09-25

280

Performance analysis on a hybrid air-conditioning system of a green building  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this system is 44.5% higher than conventional vapor compression system at a latent load of 30% and this improving can be achieved by ...

2006-05-15

281

Isolation condenser passive cooling of a nuclear reactor containment  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven cooling water pond-containing space, the gravity ...

1991-10-22

282

Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is ...

1994-07-01

283

Emergency reactor core cooling device  

International Nuclear Information System (INIS)

The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the structure. Accordingly, a ...

1993-03-16

284

Emergency core cooling device  

International Nuclear Information System (INIS)

In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...

1990-10-29

285

Chalk point cooling tower project: effects of simulated saline cooling tower drift on woody species. Master's thesis  

Science.gov (United States)

Cooling towers of power plants are used to dissipate waste heat into the atmosphere. If saline water is used for cooling, a saline aerosol known as drift is released into the atmosphere. Drift effects on vegetation are not well known. To simulate drift for a field study, cooling tower basin water was sprayed thirty separate times during a 46-day period in 1975 on Virginia pine (Pinus virginiana), flowering dogwood (Cornus florida), tulip tree (Liriodendron tulipfera), and California privet (Ligustrum ovalifolium), Norway spruce (Picea abies), and white ash (Fraxinus americana) were added in 1976 and all trees were sprayed 43 times during a 59-day period. Only dogwood leaves showed significant injury. Absence of injury on other species was probably due to the ability of their leaves to exclude, or reduce absorption of, toxic concentrations of the ions supplied.

1977-07-01

286

Ab initio Stellar Astrophysics: Reliable Modeling of Cool White Dwarf Atmospheres  

CERN Document Server

Over the last decade {\\it ab initio} modeling of material properties has become widespread in diverse fields of research. It has proved to be a powerful tool for predicting various properties of matter under extreme conditions. We apply modern computational chemistry and materials science methods, including density functional theory (DFT), to solve lingering problems in the modeling of the dense atmospheres of cool white dwarfs ($T_{\\rm eff}\\rm <7000 \\, K$). Our work on the revision and improvements of the absorption mechanisms in the hydrogen and helium dominated atmospheres resulted in a new set of atmosphere models. By inclusion of the Ly-$\\rm \\alpha$ red wing opacity we successfully fitted the entire spectral energy distributions of known cool DA stars. In the subsequent work we fitted the majority of the coolest stars with hydrogen-rich models. This finding challenges our understanding of the spectral evolution of ...

2010-01-01

287

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

289

Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries  

UK PubMed Central (United Kingdom)

Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available

2005-07-09

290

Radiation therapy alone versus radiation therapy and chemotherapy in the management of Hodgkin's disease.  

UK PubMed Central (United Kingdom)

Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available

1990-02-01

291

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

292

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

293

Lagranzheva dinamika kollektivnykh vzaimodejstvij v potokakh diskretnykh izluchatelej. (Lagrange dynamics of collective interactions in flows of discrete radiators).  

Science.gov (United States)

Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...

1989-01-01

294

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

295

Are natural radioactive materials dangerous  

International Nuclear Information System (INIS)

The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).

1974-09-23

296

A radiator of electromagnetic waves with a combined shape of generatrices  

British Library Electronic Table of Contents (United Kingdom)

The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.

2008-01-01

297

Using ICCD as a fast optical switch to measure harmonic super-radiation from an optical klystron in a storage ring  

International Nuclear Information System (INIS)

An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate

2001-07-01

298

The medical exposures to ionizing radiations, it is a world priority in radiation protection  

International Nuclear Information System (INIS)

The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)

299

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

300

VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...  

Science.gov (United States)

Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...

301

Treatment of persons exposed in radiation accidents or nuclear explosions. Omhaendertagande av skadade vid radiakolyckor och kaernvapenexplosioner  

Energy Technology Data Exchange (ETDEWEB)

The report gives general principles of treatment and care of casualties caused by radiation accidents or nuclear explosions.

1991-01-01

302

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

304

Tachyon Cerenkov radiation  

Energy Technology Data Exchange (ETDEWEB)

By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.

1985-09-01

305

Solar Cell Radiation Response near the Interface of Different ...  

Science.gov (United States)

... Solar Cell Radiation Respinnse Near the Interface o~f fliffprerv- ... 5 4. CALCUTl-ATED SOLAR CELL RLSPONSE FOR VARIOUS BASE MATERIALS ...

1971-11-01

306

Relationship of Optical Coating on Thermal Radiation ...  

Science.gov (United States)

drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...

307

References | Radiation Protection | US EPA  

Wastenet

...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...

308
309

Radiation deamination of tetracycline. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.

1980-01-01

310

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compounds in EBR-II and FFTF  

Energy Technology Data Exchange (ETDEWEB)

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF

1999-05-01

311

Onclas U9800 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

the probability of its spontaneous radiation de-excitation increases. ... consider spontaneous radiation transitions. We will examine the ...

312

Numerical analysis of methane-air combustion considering radiation effect  

Energy Technology Data Exchange (ETDEWEB)

Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to ...

2008-12-15

313

Numerical analysis of methane-air combustion considering radiation effect  

International Nuclear Information System (INIS)

Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the ...

2008-12-01

314

Multifunctional, Boron-Foam Based Radiation Shielding  

Science.gov (United States)

PROPOSAL NUMBER: 04 B3.09-7744. SUBTOPIC TITLE: Radiation Shielding to Protect Humans. PROPOSAL TITLE: Multifunctional, Boron-Foam Based ...

315

Mathematical Analysis of Three Free-Electron-Laser Issues  

Science.gov (United States)

... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...

1990-09-30

316

Equipment hardening and hardness assurance  

International Nuclear Information System (INIS)

The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...

317

Enhanced coherent undulator radiation from bunched electron beams  

International Nuclear Information System (INIS)

When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...

1995-09-28

319

ESR study in radiation damage in pyrimidines. 3-year comprehensive progress report  

International Nuclear Information System (INIS)

General mechanisms of radiation damage to biomolecules was studied by using substituted pyrimidines, particularly barbituric acid derivatives.

320

Differences in synchrotron radiation induced gas desorption from stainless steel and aluminium alloy  

CERN Document Server

Differences in synchrotron radiation induced gas desorption from stainless steel and aluminium alloy

1990-01-01

321

Combined Radiation and Thermal Injury after Nuclear Attack  

Science.gov (United States)

... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...

2011-05-13

322

Chinese Journal of Lasers (Selected Articles)  

Science.gov (United States)

... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...

1991-12-10

323

An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors  

UK PubMed Central (United Kingdom)

PurposeTo evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors.Methods...Full Text Available

2008-04-01

324

Options for passive containment cooling in next-generation nuclear plant designs  

International Nuclear Information System (INIS)

A design for passive cooling of large containment structures has progressed sufficiently to move forward into the detailed design stage necessary for plant construction. For such application, a safety analysis report has already been submitted to the US Nuclear Regulatory Commission. The design considers an annulus between the inner steel containment vessel and outer, thick-walled concrete shield building with chimney-like natural convection cooling driven only by a density gradient relative to the atmosphere. Air within the annulus is heated as internal containment temperature rises and heat is transferred through the steel containment shell. The resulting air density gradient between the annulus and the environment causes the heated air to rise, producing a natural convection flow through inlets in the shield building, past the steel shell, and out an exit chimney. Several options for enhancing passive heat removal of large containment ...

1993-11-01

325

Dynamics and developing of natural circulation cooling from vertical upflow and downflow conditions  

International Nuclear Information System (INIS)

Several research programs have been conducted to evaluate the capability of natural circulation cooling of reactors following a loss of cooling accident. Both experimental and RELAP5 simulation results were obtained for these studies in a facility with vertical heated tube(s) and a unheated bypass channel. The analytical results showed that, under a certain power level, a natural circulation pattern can be developed from both initial upflow and downflow conditions, and maintained for a significant cooling period. This power level, for the discussion of this paper, is defined as the natural circulation cooling (NCC) power limit. Two import factors, namely the pump coastdown rate and the initial flow direction, are examined in this paper. In the benchmark case, as compared to the experimental results, the RELAP5 simulation program accurately predicted the transient phenomena from forced convection through ...

1994-04-05

326

Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions  

Energy Technology Data Exchange (ETDEWEB)

The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB ...

1999-06-19

327

A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom  

Energy Technology Data Exchange (ETDEWEB)

A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a ...

2008-02-21

328

Transformation kinetics and microstructures of Ti17 titanium alloy during continuous cooling  

International Nuclear Information System (INIS)

We have investigated the microstructure evolutions in the Ti17 near #beta# titanium alloy during heat treatments. The phase transformation has first been studied experimentally by combining X-ray diffraction analysis, electrical resistivity and microscopy observations. From a series of isothermal treatments, a IT diagram has been determined, which takes into account the different morphologies. Then, a Johnson-Mehl-Avrami-Kolmogorov (JMAK) model has been successfully used to describe the phase transformation kinetics during either isothermal or cooling treatments. Finally, the coupling of the JMAK model to the finite element software ZeBuLoN allowed us to investigate the evolution of the spatial distribution of the different morphologies during the cooling of an aircraft engine shaft disk after forging.

2007-03-15

329

Thermal-hydraulic analysis following a safety flapper valve's fault for a pool-type research reactor  

International Nuclear Information System (INIS)

One of the characteristic safety features of a pool type research reactor is a safety flapper valve. The valve enables natural convection cooling mechanism in one of the following events. (a) Opening flapper valve promote decay heat removal following reactor's shutdown. (b) Also the valve is gravity driven. There is a possibility that the valve fails to open when it is required to do so. In the present paper the cooling characteristics of the core are analyzed for this event. A steady state study was performed for 5 MW power and 18 FE following a reactor shutdown. It is shown that enough margin exists to assure adequate reactor core cooling should the safety flapper valve fails to open. (authors)

330

System for cooling primary gas coolers using return water stabilized by means of ammonium sulfate  

Energy Technology Data Exchange (ETDEWEB)

Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.

1989-08-01

331

Study of phosphonate addition and hydrodynamic conditions on ordinary steel corrosion inhibition in simulated cooling water  

British Library Electronic Table of Contents (United Kingdom)

The effect of phosphonate anion (PHOS) on the corrosion of ordinary steel in simulated cooling water has been studied using weight loss, polarization curves and electrochemical impedance spectroscopy measurements. PHOS was studied in the concentration range from 7.5x10^-^5 to 10^-^3M. The results obtained reveal that PHOS perform excellently as corrosion inhibitor for ordinary steel in simulated cooling water. The inhibition efficiency of PHOS was increased with increasing both its concentration and water circulation velocity. These two factors seem to promote the adsorption of phosphorus and oxygen ions on the metal surface, leading to the formation of a protective layer with a greater charge transfer resistance and lower permeability. The inhibition efficiency decreased slightly with tem...

2010-01-01

332

Soft cooling with concrete: A simple system ensures a comfortable room climate; Sanfte Kuehlung aus Beton: Behagliches Raumklima mit einfachem System  

Energy Technology Data Exchange (ETDEWEB)

After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)

1999-10-01

333

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

Energy Technology Data Exchange (ETDEWEB)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10{sup -4} M to 10{sup -1} M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhibitor.

2008-06-15

334

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

British Library Electronic Table of Contents (United Kingdom)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10-4M to 10-1M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhi...

2008-01-01

335

Safety considerations of active process water system shutdown for TAPP - 3 and 4  

International Nuclear Information System (INIS)

Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)

2005-12-01

336

Progress on the Design and Fabrication of the MICE Focusing Magnets  

Energy Technology Data Exchange (ETDEWEB)

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.

2009-10-19

337

Process development for continuous crystallization of fat under laminar shear  

British Library Electronic Table of Contents (United Kingdom)

A novel continuous laminar shear structuring crystallizer with a suitable cooling system was designed and built. This is a new method to continuously crystallize edible fat in the desirable polymorphic form from the melt while being uniformly sheared.The machine consists of four main sections: Feed unit, shearing mechanism, cooling system and power unit. In each of these sections specific design considerations are taken into account which makes the process controllable and continuous. The shearing unit is made of two concentric cylinders. The internal cylinder is stationary and has a cooling system inside for temperature control. The outer cylinder rotates to produce a uniform shear in the sample fluid placed in the 1.5mm gap between the cylinders. The sample's feed rate is controlled whil...

2008-01-01

338

Post-operative hilotherapy in SMAS-based facelift surgery: A prospective, randomised, controlled trial  

British Library Electronic Table of Contents (United Kingdom)

Background: Ecchymosis, oedema, haematoma and pain after SMAS-based facelift surgery are all the direct result of the physical trauma of surgery and subsequent inflammatory response. Hilotherapy is a novel form of cryotherapy that purports to minimise these events through single-use face masks circulating cooled, sterile water. This study was performed to assess the validity of Hilotherapy in this population of patients. Methods: Over 14 weeks fifty consecutive patients were randomised to post-operative facial cooling with Hilotherapy or management with standard dressings alone, while fifteen subsequent, consecutive patients were randomised to cooling of one side of the face but not the other. Assessment of ecchymosis, oedema, haematoma and pain was performed independently by clinical staf...

2011-01-01

339

Natural convection cooling of the IFMIF target and test cell  

International Nuclear Information System (INIS)

The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.

2007-10-01

340

Liquid metal reactor cover gas purification and analysis in the USA  

International Nuclear Information System (INIS)

Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.

1986-09-24

341

Horizontal ground coupled heat pump: Thermal-economic modeling and optimization  

Energy Technology Data Exchange (ETDEWEB)

The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters with the climatic conditions, ...

2010-12-15

342

Helium-cooling in fusion power plants  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews different helium-cooled first wall and blanket designs; and compares the selection of structural materials. The authors found that the solid breeder, SiC-composite material option generates the lowest amount of induced radioactivity and afterheat and has the highest temperature capability. When combined with the direct cycle gas turbine system, it has the potential to be the most economical fusion system and can compete with advanced fission reactors. When compared to martensitic steel and V-alloy, SiC-composite is the least developed of these three structural materials, a focused development effort will be needed. Fundamental research has begun in addressing the issues of optimized composite materials, irradiation effects, leak tightness and low activation braze materials. Development of helium-cooled high heat flux components and further development of the direct cycle gas turbine system will also be needed.

1994-11-01

343

Heat and fluid flow during the formation of metallic glasses by splat cooling  

Science.gov (United States)

A model is presented for heat and fluid flow during hammer and anvil splat cooling. Predictions are made for the effects of superheat and hammer speed on splat thickness, cooling rate, and subsequent glass formation. The regime of Newtonian heat flow is extended well beyond the previously accepted limiting value of Nusselt number. Measurements of the structure, stability, and thickness of Fe{sub 80}B{sub 20} and Pd{sub 80}Si{sub 20} hammer and anvil splats qualitatively confirm the model prediction. Variations of superheat in shock tube splats produced similar trends to those observed in the hammer and anvil device. In an attempt to vary the equivalent of hammer speed in a shock tube device, an orifice producing a supersonic shock wave was utilized. Significant splat flake thickness reductions resulted as compared to subsonic orifices.

344

Cooling/heating augmentation during turbine startup/shutdown using a seal positioned by thermal response of turbine parts and consequent relative movement thereof  

Energy Technology Data Exchange (ETDEWEB)

In a turbine rotor, a thermal mismatch between various component parts of the rotor occurs particularly during transient operations such as shutdown and startup. A thermal medium flows past and heats or cools one part of the turbine which may have a deleterious thermal mismatch with another part. By passively controlling the flow of cooling medium past the one part in response to relative movement of thermally responsive parts of the turbine, the flow of thermal medium along the flow path can be regulated to increase or reduce the flow, thereby to regulate the temperature of the one part to maintain the thermal mismatch within predetermined limits.

2000-01-01

345

Containment closure time following loss of cooling under shutdown conditions of YGN units 3 and 4  

Energy Technology Data Exchange (ETDEWEB)

The YGN Units 3 and 4 plant conditions during shutdown operation were reviewed to identify the possible event scenarios following the loss of shutdown cooling. The thermal hydraulic analyses were performed for the five cases of RCS configurations under the worst event scenario, unavailable secondary cooling and no RCS inventory makeup, using the RELAP5/MOD3.2 code to investigate the plant behavior. From the analyses results, times to boil, times to core uncovery and times to core heat up were estimated to determine the containment closure time to prevent the uncontrolled release of fission products to atmosphere. These data provide useful information to the abnormal procedure to cope with the event. 6 refs., 7 figs., 2 tabs. (Author)

1998-12-31

346

Characterizing the time variability in magnetized neutrino--cooled accretion disks: signatures of the gamma-ray burst central engine  

CERN Document Server

The central engine of Gamma Ray Bursts is hidden from direct probing with photons mainly due to the high densities involved. Inferences on their properties are thus made from their cosmological setting, energetics, low-energy counterparts and variability. If GRBs are powered by hypercritical accretion onto compact objects, on small spatial scales the flow will exhibit fluctuations, which could in principle be reflected in the power output of the central engine and ultimately in the high energy prompt emission. Here we address this issue by characterizing the variability in neutrino cooled accretion flows through local shearing box simulations with magnetic fields, and then convolving them on a global scale with large scale dynamical simulations of accretion disks. The resulting signature is characteristic, and sensitive to the details of the cooling mechanism, providing in principle a discriminant for GRB central engine properties.

2010-01-01

347

COSY synchrotron and storage ring for medium energy physics  

Energy Technology Data Exchange (ETDEWEB)

At present the cooler synchrotron COSY a synchrotron and storage ring for medium energy physics is being commissioned at Juelich. The construction of the ring was finished during September 1992. The cooler ring will deliver protons in the momentum range from 270 to 3300 MeV/c. The phase density of the circulating protons will be increased with electron cooling at injection and with stochastic cooling at momenta between 1500 and 3300 MeV/c. High luminosity internal experiments as well as high resolution external experiments will be possible. Details of the lattice, to match the different ion optical requirements for cooling, acceleration, internal experiments and ultra-slow extraction will be discussed. An overview of the performance of the ion sources, the injector cyclotron, the ring, the injection beamline are given. The realization status of the extraction beamlines to the external experimental area is given. The ...

1993-01-01

348

Building design using the energy nomographs  

Energy Technology Data Exchange (ETDEWEB)

Today's building industry is promoting the use of renewable sources of energy to heat, cool, and illuminate commercial buildings. Societies such as the International Solar Energy Society sponsor conferences such as this one to share knowledge and experience in the area of solar energy. However, the technologies presented here assume a need for heating, cooling or illumination. A simple technique is presented for determining the actual heating, cooling, and lighting requirements for commercial buildings, and for reducing those requirements through proper building design before applying solar technologies. The energy nomographs are a graphic energy design tool developed to aid designers in making cost effective decisions about energy alternatives early in the design process. Reducing loads at this point can help reduce the expense of a passive or active solar system which is usually sized to meet a certain percentage ...

1983-06-01

349

uv photobiology: postreplication repair. [Escherichia coli, synchrotron radiation  

Science.gov (United States)

The following topics are discussed: insertion of incorrect bases in DNA; ability of DNA polymerase to copy uv-irradiated DNA; role of enzymes in repair of DNA; effects of uv radiation on molecular weight of DNA; photoreactivation; repair of DNA in Escherichia coli and xp cells following uv radiation; and synchrotron radiation studies on DNA repair. (HLW)

1978-01-01

352

Tumorigenic and tumoricidal actions of ionizing radiations  

Energy Technology Data Exchange (ETDEWEB)

The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.

1983-01-01

353

The influence of stray radiation on image quality  

International Nuclear Information System (INIS)

The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).

356

Surprising collectivity in neutron-rich iron isotopes  

International Nuclear Information System (INIS)

... VDPEAZ (Bonn 2010 issue) NUCLEAR PHYSICS AND RADIATION PHYSICS

2010-03-15

360

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

362

Solar Radiation Pressure Binning for the Geosynchronous Orbit  

Science.gov (United States)

Orbital maintenance parameters for individual satellites or groups of satellites have traditionally

2011-01-01

363

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

365

Radiological equipment for emergencies  

Energy Technology Data Exchange (ETDEWEB)

A brief guide to training and equipment needed to effectively manage victims of radiation accidents. (DT)

1985-01-01

369

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).

370

Radiation processing used in forestry in Thailand  

Energy Technology Data Exchange (ETDEWEB)

A summary is presented of research being carried out in Thailand on the preparation of irradiation-impregnated wood.

1981-01-01

371

Radiation effects on the shoot tip culture of chrysanthemum  

International Nuclear Information System (INIS)

Japanese (Mar 1974). Japan Mabuchi, Toshio Kuwada, Hikaru . Kagawa Univ.,

374

Radiation and fetal brain development  

International Nuclear Information System (INIS)

(4 Sep 1986). United Kingdom Zamenhof, Stephen . California Univ., Los

375

Radiation Protection of the Organism (Selected Chapters)  

Science.gov (United States)

... biologically important compounds is sharply lowered with passage of the solutions to the cell an organ, where their sensitivity ...

1970-12-11

376
378

Possibility of production of new superheavy nuclei in complete fusion reactions  

International Nuclear Information System (INIS)

... of Sciences (Poland) [5.48 Megabytes] NUCLEAR PHYSICS AND RADIATION

2008-09-01

379

Nuclear physics with a free electron laser  

International Nuclear Information System (INIS)

... radiation parity photonuclear reactions polarized beams resonance

381

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

382

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

384

Kinetics of low-temperature radiation hardening of metallic materials under irradiation  

British Library Electronic Table of Contents (United Kingdom)

A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.

2011-01-01

386

Infrared processes in the auroral zone  

International Nuclear Information System (INIS)

... aurorae carbon dioxide emission spectra infrared radiation nitrogen nitrogen

8432-01-01

388

Induced radiation during scattering of channeled electrons and positrons by point defects  

Energy Technology Data Exchange (ETDEWEB)

In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.

1984-12-01

392

ISR site  

CERN Document Server

A last look at the green field, in the triangular wedge of land stray radiation near the CERN accelerators.

1965-01-01

393

Free radicals in lysozyme reacted with peroxidizing methyl linoleate  

International Nuclear Information System (INIS)

... electron spin resonance gamma radiation lipids lyophilization lysozyme radicals

394

Four cases of bowel perforation following radiation therapy for cervical cancer  

Energy Technology Data Exchange (ETDEWEB)

External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.

1984-10-01

395

Experts' discussion on the possibility of quantification of the radiation hazard  

International Nuclear Information System (INIS)

Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).

1978-01-01

398

Effective dose equivalent in nuclear medicine investigations  

International Nuclear Information System (INIS)

... radiation hazards hazards health hazards MEDICINE. SOMATICALLY

1984-05-07

401

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

402

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

403

Cooperative spontaneous emission from two different atoms  

International Nuclear Information System (INIS)

The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).

1986-01-01

405

Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer  

UK PubMed Central (United Kingdom)

BackgroundTo compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated...Full Text Available

406

Cluster-loop structure influence on molybdenum radiation hardening  

International Nuclear Information System (INIS)

Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).

1990-05-22

412

About tachyons  

International Nuclear Information System (INIS)

... Part A: The electromagnetic radiation of a charged tachyon. Part B: Some

413

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

415

Theory of edge radiation  

CERN Document Server

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge ...

2008-01-01

416

Radiative corrections to the atomic levels in a periodic electromagnetic field  

Energy Technology Data Exchange (ETDEWEB)

The influence of a periodic electromagnetic field on the radiative corrections to the atomic energy levels is studied for the case of ''strong fields'' for which the interaction between the atom and field is of the order or greater than the radiative effects. The analysis is carried out on the basis of the Schwinger-Dirac equation for the propagation function of a bound electron in the field and on the basis of the density matrix in the Furry representation. It is shown that in the strong field approximation the radiative shifts and widths are manifest as radiative corrections to the quasi-energies. In super-high resolution experiments intensity effects in the radiative corrections to the atomic levels are obtained in the case of single-photon resonance. Some multiphoton processes are condidered by taking into account the effect of the field on ...

1982-12-01

417

Biological radiation effects  

International Nuclear Information System (INIS)

The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable alterations in tissues and ...

1976-01-01

418

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...

2008-05-01

419

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...

420

Turbine air intake treatment  

Energy Technology Data Exchange (ETDEWEB)

Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)

1999-07-01

421

Toxicity of radioactive wastes generated from PEACER spent fuel  

Energy Technology Data Exchange (ETDEWEB)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially {sup 90}Sr and {sup 137}Cs are dominant contributor nuclides until 30 years and especially {sup 90}Sr and {sup 137}Cs have the highest activity and decay heat than other LLFP. In this study, recovery of {sup 90}Sr and {sup 137}Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 ...

2003-10-01

422

Toxicity of radioactive wastes generated from PEACER spent fuel  

International Nuclear Information System (INIS)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 after 1000 years ...

2003-10-01

423

Toxicity of Radioactive Wastes Generated from PEACER in Korea  

International Nuclear Information System (INIS)

Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyro-processing. In the assessment of long-lived fission products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02 E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26 E+05 after 100 years cooling, 1.97 E+04 after 300 years cooling, 9.52 E+03 after 1000 years ...

2006-06-04

424

The influence of the explosion of the conductor of an electric cable on the dielectric properties of the polymer insulator  

British Library Electronic Table of Contents (United Kingdom)

The electric explosion of a conductor being part of an electric cable is studied. It is ascertained that the electric properties of a polymeric dielectric depend nonlinearly on the maintenance of the ultradisperse metal filler. In the course of the numerous heating-cooling processes of an insulator, a streamlining of the structure of a polymeric composite occurs.

2010-01-01

425

Telephone, mail, and personal questionnaires for data collection. [For heating and cooling  

Energy Technology Data Exchange (ETDEWEB)

Forms used in conducting a national survey about solar energy are presented. Forms for representatives from the domestic, commercial, and industrial sectors, owners and non-owners of solar equipment, are shown. Participants were to be contacted by telephone, mail, and personal visits. (MCW)

1980-02-20

426

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various components of the TPC magnet cryogenics system besides the magnets and control dewar; (3) the control dewar and ...

1980-03-01

427

Study of the Energy Efficiency of the Melting Unit at the Rockwool Company Mineral Wool Process in Skoevde, Sweden.  

Science.gov (United States)

The melting unit, consisting of a water-cooled cupola furnace, afterburner, heat exchanger, air preheater, consumes most of the supplied energy in the rockwool process. The report maps the energy flows and defines factors of merit according to thermodynam...

1979-01-01

428

Simplified procedure for sizing and analyzing thermal energy storage in commercial and institutional buildings and generation of plots for North Carolina  

Energy Technology Data Exchange (ETDEWEB)

The objective of the project was to provide a readily understandable and usable methodology for preliminary analysis of the economic benefit that can accrue from the use of thermal energy storage for building heating and cooling. The procedure was to be capable of providing an estimate of cooling plant and storage size, as well as the monthly savings that can be saved. The research focused on the development of a procedure for a limited class of commercial and institutional buildings in North Carolina. A simplified procedure for analyzing the potential for using thermal energy storage (TES) in such buildings in North Carolina was developed. The procedure developed consists of charts and nomographs that can be used for estimating the size of TES systems, and for estimating the monthly demand savings. The monthly demand savings can be combined with the applicable rate schedule to determine the annual cost savings. An overview of the procedure and ...

1981-06-30

429

Precipitation during controlled cooling of magnesia-partially-stabilized zirconia  

Energy Technology Data Exchange (ETDEWEB)

A study has been made of the precipitation and growth processes which occur during cooling from solution treatment and under isothermal hold conditions in a magnesia-partially-stabilized zirconia alloy. Three types of precipitate have been identified which develop during cooling or during isothermal hold treatments just above and below the eutectoid temperature. These precipitate forms are termed (i) primary, (ii) large random, and (iii) secondary. Further precipitation, slow growth of existing precipitates, and subeutectoid decomposition result when an additional 1100/sup 0/C aging treatment is given to the previously cooled material. It is shown that type (iii) secondary precipitates from rapidly within the temperature range of 1300/sup 0/ to 1375/sup 0/C. The secondary precipitates are largely responsible for the improved room-temperature strength properties of the heat-treated samples. The formation and effects on ...

1986-07-01

430

Precipitation during controlled cooling of magnesia-partially-stabilized zirconia  

International Nuclear Information System (INIS)

A study has been made of the precipitation and growth processes which occur during cooling from solution treatment and under isothermal hold conditions in a magnesia-partially-stabilized zirconia alloy. Three types of precipitate have been identified which develop during cooling or during isothermal hold treatments just above and below the eutectoid temperature. These precipitate forms are termed (i) primary, (ii) large random, and (iii) secondary. Further precipitation, slow growth of existing precipitates, and subeutectoid decomposition result when an additional 1100"0C aging treatment is given to the previously cooled material. It is shown that type (iii) secondary precipitates from rapidly within the temperature range of 1300"0 to 1375"0C. The secondary precipitates are largely responsible for the improved room-temperature strength properties of the heat-treated samples. The formation and effects on mechanical ...

431

Policy implications of funding DOE's K Reactor Cooling tower Project  

Energy Technology Data Exchange (ETDEWEB)

This report has reviewed the construction of a cooling tower for the K reactor at the DOE Savannah River Site in Aiken, South Carolina. It has been found that the cooling tower would prevent further destruction of cypress and tupelo trees, would maintain a more consistent flow from site streams, and would allow earlier recovery of stream corridors inside a portion of the site. About 630 acres of wetlands have already been affected by the hot water discharged by the K reactor during the past 35 years. GAO believes that about 10 to 12 acres of additional damage would be prevented by the tower for every year the reactor is operated, and if current plans for re-start and retirement of the reactor are followed, less than 100 acres would be preserved. As requested, GAO also identified an example of a project that could be funded as compensation to the public for the damage the K reactor would do if Congress exempted it from the Clean Water Act and ...

1989-10-01

432

On the natural convection cooling in HANARO (Hi-flux Advanced Neutron Application Reactor). Experiment and RELAP5/KMRR simulation  

International Nuclear Information System (INIS)

The natural circulation experiments were conducted to confirm the cooling capability and the flow characteristics of the natural convection in the HANARO (Hi-flux Advanced Neutron Application Reactor). The tests were done at the power levels of 2%, 3% and 4% (1.2MW_t_h) of full power. The flow rates and temperatures at various locations of the primary and secondary cooling loops were measured at each power level. The temperature distributions in the chimney and the pool were also obtained. Through tests, the flow paths of the natural circulation and the cooling capability of the reactor were confirmed as designed. In addition, the simulation for the natural circulation tests was made by using RELAP5/KMRR, which was modified from RELAP5/MOD2 for applying to the HANARO conditions. The simulation results show that RELAP5/KMRR gives reasonable predictions for the flow rate and the coolant temperature during natural circulation ...

433

Natural convection cooling of a close-packed array of AGR fuel pins surrounded by graphite debris  

International Nuclear Information System (INIS)

Certain postulated faults during refuelling of AGRs may give rise to compacted fuel and graphite sleeve debris. This debris must be maintained below some safe limiting temperature. As part of a programme to assess the benefits of natural convection in cooling such debris in a region experiencing no forced cooling, a simple geometry incorporating typical debris has been studied both experimentally and by prediction. The experiment comprised an array of electrically heated fuel rods mounted co-axially in a closed cylindrical vessel and surrounded by fragments of graphite. The vessel was cooled on its cylindrical surface, the ends being insulated. Rods and vessel wall were thermocoupled. Tests covered a range of temperature and pressures in both CO_2 and N_2. Significant natural convection heat removal was demonstrated, particularly at high pressure. Predictions utilising the PHOENICS code agreed well with measured ...

434

Natural circulation cooling in US Pressurized Water Reactors  

International Nuclear Information System (INIS)

This document is a synthesis of data and analysis concerning natural circulation cooling in US Pressurized Water Reactors during off-normal operation and accident transients. Its objective is the integration of important research findings concerning PWR natural circulation phenomena into a single reference document. Sources of information include the Nuclear Regulatory Commission, reactor vendors, utility sponsored research groups, utilities, national laboratories, research reports, meeting papers, archival literature, and foreign sources. Three modes of natural circulation are discussed: single-phase, two-phase, and reflux/boiling condensation. General characteristics, analytical expressions, noncondensible gas effects, secondary effects, and nonuniform flow are described with regard to each of the natural circulation modes. Plant operational data, tests in scaled experimental facilities, and analysis with thermal hydraulic system codes have demonstrated the ...

435

Mound Facility explosives incinerator  

Energy Technology Data Exchange (ETDEWEB)

The design and performance of small incinerators used at the Mound Laboratory for the disposal of explosives are described. These units, which cost less than $1000 each, are about the size of a 55-gal drum, have water jackets for cooling, and have provided a flexible, efficient, and clean burning explosives disposal unit. (LCL)

1980-01-01

436

Measured impact of neighborhood tree cover on microclimate  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present results of our investigation into the relationship between urban microclimate and the local density of tree cover as measured in Sacramento, California. These results were obtained through analysis of data collected in a two-month long monitoring program with automatic weather stations installed at 15 residential locations throughout the city. Measured wind speeds showed a highly negative correlation with respect to tree cover. Daily peak air temperatures showed significant variation often differing from site to site by 2 to 4{degrees}C ({approx}3.5 to 7{degrees}F). A complex interaction between several competing factors is discussed leading to the conclusion that additional tree cover may actually increase urban air temperatures on synoptically cool days. It is suggested that this does not have a significant adverse affect in terms of overall summer urban cooling load. This is supported by an integrated analysis of the ...

1992-08-01

437

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-01-01

438

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-11-15

439

Heating and cooling with geothermal energy: trends and accomplishments; Solutions de chauffage et de climatisation utilisant l`energie geothermique: tendances et realisations  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the heating and cooling needs of public buildings at considerable cost reductions, besides offering ...

1996-03-01

440

Heat Transfer Augmentation in Turbulent Impinging Jets.  

Science.gov (United States)

Heating and cooling by impinging jets is widely used in various engineering applications, due to the high heat transfer rates prevailing in the vicinity of the stagnation point. The authors have been able to utilize acoustically excited turbulence for the...

1979-01-01

441

Gas-Cooled Fast Breeder Reactor preliminary safety information document, Amendment 9. GCFR fuel cladding PC-5 (faulted) temperature limit  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning GCFR design and limiting faulted events; selection of PC-5 temperature limit; and verification test programs.

1980-02-01

442

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major ...

1981-05-01

443

Experimental Study of a Method of Mechanical Augmentation of Convective Heat Transfer Coefficients in Air.  

Science.gov (United States)

Scraped-surface heat transfer augmentation is proposed as a possible technique for use in improved air-cooling designs. Although it has been in common use with liquids, the technique has apparently never been used with gases. An experimental investigation...

1974-01-01

444

Experience with fully operational solar-driven 10-ton LiBr/H2O single-effect absorption cooling system in Thailand  

British Library Electronic Table of Contents (United Kingdom)

A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...

2008-01-01

445

Evaluation of advanced technologies for power transformers. Final report  

Energy Technology Data Exchange (ETDEWEB)

The high insulating strength of certain gases, such as sulfur hexafluoride, when used at high pressure, suggests that there may be advantages to compressed gases as the insulating fluid in power transformers. However, simply exchanging the oil for compressed gas in an otherwise conventional transformer design will not yield a significant overall advantage. Compressed gases present the engineer with properties which are quite different from mineral oil. If gases are to be used as the major insulating fluid in power transformers, then virtually all aspects of the insulation and cooling of the apparatus must be reconsidered, affording an opportunity to introduce new design concepts, new materials, and new construction techniques. In this program, the feasibility of using the following principal design concepts has been explored: sheet conductors for the windings; a system of sealed, self-contained, annular cooling ducts containing circulating ...

1981-01-01

446

Emergency core cooling device  

International Nuclear Information System (INIS)

Purpose: To effectively cool the reactor core in a steam atmosphere by upwardly directing several of spray nozzles attached to a ring header thereby increasing the flying distance of the spray. Constitution: Ring headers in two upper and lower stages are disposed above the outer circumference of a reactor core and each of the ring headers is mounted with spray nozzles. Among the spray nozzles, at least several nozzles mounted to the ring header at the lower stage are directed such that the center axis for each of the nozzle is raised above the horizontal axis and other several nozzles are mounted with the nozzle center axis directed downwardly from the horizontal axis. Accordingly, even if collapsing phenomenon occurs in the jetting stream due to the condensation in the steams that forms the operation atmosphere of the reactor core spray cooling device, a sufficient amount of emergency cooling water can be distributed over ...

1983-03-09

447

ELECTRONIC COMPONENT COOLING ALTERNATIVES: COMPRESSED AIR AND LIQUID NITROGEN  

Science.gov (United States)

The goal of this study was to evaluate topics used to troubleshoot circuit boards with known or suspected thermally intermittent components. Failure modes for thermally intermittent components are typically mechanical defects, such as cracks in solder paths or joints, or broken b...

448

Cylindrical stretched flame  

Energy Technology Data Exchange (ETDEWEB)

For sufficiently cool remote gases, the cylindrical stretched flame shows classical ignition-extinction behavior. For remote gas temperatures close to the adiabatic flame temperature, the flame response is qualitatively different, with negative flame speed solutions which may be physically accessible.

1984-06-01

449

Conceptual design of a medium scale lead-bismuth cooled fast reactor  

International Nuclear Information System (INIS)

To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. A comparative design study is performed on Lead-Bismuth cooled reactors with forced and natural convection cooling. Eliminating an intermediate cooling system makes the heat transport system simple and can decrease the amount of the weight of NSSS. Based on the estimation of the amount materials, the plant internal load etc., a construction cost of these plants are evaluated approximately 2/3 times of that of LWRs at present. And, the nitride fuel makes breeding ratio of 1.2 with 150 GWd/t of burnup. The results of unprotected event analyses such as UTOP and ULOF show that both of concepts have possible features ...

2003-09-15

450

Conceptual design for accelerator-driven sodium-cooled sub-critical transmutation reactors using scale laws  

Energy Technology Data Exchange (ETDEWEB)

The feasibility study on conceptual design methodology for accelerator-driven sodium-cooled sub-critical transmutation reactors has been conducted to optimize the design parameters from the scale laws and validates the reactor performance with the integrated code system. A 1000 MWth sodium-cooled sub-critical transmutation reactor has been scaled and verified through the methodology in this paper, which is referred to Advanced Liquid Metal Reactor (ALMR). A Pb-Bi target material and a partitioned fuel are the liquid phases, and they are cooled by the circulation of secondary Pb-Bi coolant and by primary sodium coolant, respectively. Overall key design parameters are generated from the scale laws and they are improved and validated by the integrated code system. Integrated Code System (ICS) consists of LAHET, HMCNP, ORIGEN2, and COMMIX codes and some files. Through ICS the target region, the core region, and ...

1998-12-31

451

Collisional cooling of negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

Studies have been conducted to determine the feasibility of using collisional cooling for reducing emittances and energy spreads in negative-ion beams to levels commensurate with effective isobaric purification with conventional high-resolution electromagnetic isobar separators as required for use at the Holifield Radioactive Ion Beam Facility (HRIBF). We have designed a gas-filled radio frequency quadrupole ion cooler equipped with provisions for retarding energetic negative-ion beams to energies below thresholds for electron detachment at injection and for re-acceleration to initial energies after the cooling process. The device has been used to cool several ion beams with initial energy spreads, {delta}E>10 eV to final energy spreads, {delta}E{approx}2 eV FWHM, including O{sup -} and F{sup -}. Overall transmission efficiencies of {approx}14% for F{sup -} beams have been obtained. Experimental results show that ...

2002-01-01

452

Chalk Point Cooling Tower Project: Drift Salinity Experiments.  

Science.gov (United States)

Results of feasibility experiments for determining the mineral content of individual stains on special Sensitized Paper are presented. The stains were formed on the paper by the impaction of laboratory generated salt water droplets. Of the techniques exam...

1979-01-01

453

Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.  

Science.gov (United States)

This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...

1979-01-01

454

Biogenic carbon and anthropogenic pollutants combine to form a cooling haze over the southeastern United States  

UK PubMed Central (United Kingdom)

Remote sensing data over North America document the ubiquity of secondary aerosols resulting from a combination of primary biogenic and anthropogenic emissions. The spatial and temporal distribution...Full Text Available

2009-06-02

455

Air conditioning of future small urban electric cars by thermoelectricity  

Energy Technology Data Exchange (ETDEWEB)

Air conditioning of urban electric cars by Peltier effect is simulated. Advantages (noise, simplicity of construction and of regulation, good heating performances...) and disadvantages (cooling performances lower than actual compressors, actual costs...) are presented. (A.B.). 8 refs., 5 figs.

1994-01-01

456

A statistically-selected Chandra sample of 20 galaxy clusters -- II. Gas properties and cool-core/non-cool core bimodality  

CERN Document Server

We investigate the thermodynamic and chemical structure of the intracluster medium (ICM) across a statistical sample of 20 galaxy clusters analysed with the Chandra X-ray satellite. In particular, we focus on the scaling properties of the gas density, metallicity and entropy and the comparison between clusters with and without cool cores (CCs). We find marked differences between the two categories except for the gas metallicity, which declines strongly with radius for all clusters (Z ~ r^{-0.31}), outside ~0.02 r500. The scaling of gas entropy is non-self-similar and we find clear evidence of bimodality in the distribution of logarithmic slopes of the entropy profiles. With only one exception, the steeper sloped entropy profiles are found in CC clusters whereas the flatter slope population are all non-CC clusters. We explore the role of thermal conduction in stabilizing the ICM and conclude that this mechanism alone is sufficient to balance ...

2009-01-01

457

A rare case of neuroleptic malignant syndrome presenting with serious hyperthermia treated with a non-invasive cooling device: a case report  

UK PubMed Central (United Kingdom)

IntroductionA rare side effect of antipsychotic medication is neuroleptic malignant syndrome, mainly characterized by hyperthermia, altered mental state, haemodynamic dysregulation,...Full Text Available

458

A New Efficient Method of Topical Cooling and Rewarming of the Myocardium  

UK PubMed Central (United Kingdom)

Profound myocardial hypothermia (below 17° C, and more often around 12° C) is imperative in myocardial protection while the aorta is cross-clamped. Based on our experience in...Full Text Available

1985-12-01

459

10:10 - progress on our pledges | Environment | The Guardian  

Wastenet

... At the Vintage at Goodwood festival we're curating this summer, we intend to demonstrate how sustainability can be cool without being hippy in 2010. It really can - I'm the living embodiment of that . . .\\

460

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

461

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

462

Study of emission of Cerenkov radiation by tachyons  

International Nuclear Information System (INIS)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation. (author).

463

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

464

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

465

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

466

Radiation-stimulated diffusion of aerosols  

Energy Technology Data Exchange (ETDEWEB)

The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.

1984-04-01

467

Radiation-induced chemical modification of wood  

International Nuclear Information System (INIS)

The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.

1985-01-01

468

RADSOLVER: a computer program for calculating spectrally-dependent radiative heat transfer in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.

1981-09-01

469

Practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc

2004-05-01

470

New concepts in risk assessment for patients with radiological treatment  

International Nuclear Information System (INIS)

In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.

1986-01-01

471

Difference between delayed radiation-necroses of the cerebral hemispheres and midline: its bearing in radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.

1980-08-01

472

Decommissioning and dismantling. Examination of the radiation hardening of electronic components. Final report  

International Nuclear Information System (INIS)

Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).

473

Comparison and analysis of results of ? radiation level investigation around Daya Bay  

International Nuclear Information System (INIS)

Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)

2003-08-01

474

The onset conditions of enhancement of ice accumulation associated with heat-conducting plates located perpendicularly to heat-transfer surfaces; Part 1: Analysis for still water  

Energy Technology Data Exchange (ETDEWEB)

An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.

1994-07-01

475

The natural convection cooling with vaporizing deuterium for the horizontally arranged cold neutron source of the HFR - Grenoble  

International Nuclear Information System (INIS)

Natural convection of vaporizing Deuterium at 25 K transports the heat generated in the moderator cell of the cold neutron source to a He cooled condenser. The thermohydraulics of this thermosiphon were precalculated and the results verified by experiments in a 1:1 model using D_2 as fluid. The experimental results show that the thermosiphon operates stable. The demanded liquid content of the cell as well as wall temperatures below 50 K can be ensured by a proper design of the cell outlet flow geometry. A 7 min. loss of cryogenic power results in transient temperatures of the cell wall of not more than 300 K.

1991-08-01

476

Reconsidering the site requirements for NPP on Olt River  

International Nuclear Information System (INIS)

Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling ...

2009-10-12

477

Production of blast furnace coke via novel briquetting system  

Science.gov (United States)

A method of making high strength coke briquettes suitable for use as blast furnace coke comprising, (A) providing coal, (B) heating the coal at a temperature at or above the softening point of the coal to form partially carbonized char, (C) cooling the partially carbonized char below the softening point of the coal, (D) mixing the cooled partially carbonized char and tar to form a mixture of tar and partially carbonized char, (E) briquetting the mixture of tar and partially carbonized char to form briquettes of tar and partially carbonized char, (F) calcinating the briquettes to form high strength briquettes.

1982-12-07

478

Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.

2002-08-01

479

Natural convection cooling of circumferentially finned transport casks  

International Nuclear Information System (INIS)

It may be stated that for the calculation of the heat transfer coefficients for natural convection cooling of large-diameter finned surfaces it is necessary to take in consideration the effects of the fin length, fin material and of the azimuthal angle around the cylinder. The present results replace earlier less accurate correlations gained from the same measurements. The new, better correlation was elaborated with the aid of the improved method of evaluation of multiple parameters of a measurement matrix of multiple dimension (one dimension for each parameter), rendering the sum of the squares error a minimum at the same time for the complete matrix. 5 references.

1983-12-01

480

More iPhone Cool Projects  

CERN Document Server

Everyone is developing iPhone applications, and it's clear why. The iPhone is the coolest mobile device available, and the App Store makes it simple to get an application out into the unstoppable iPhone app market. With hundreds of thousands of app developers entering the game, it's crucial to learn from those who have actually succeeded. This book shows you how some of the most innovative and creative iPhone application developers have developed cool, best-selling apps. Not only does every successful application have a story, but behind every great app is excellent code. In this book, you'll

2010-01-01

481

Loss of flow accident analysis of a water-cooled fusion reactor  

International Nuclear Information System (INIS)

Within the APROS simulation environment we have built a thermo-hydraulic model of a conceptual fusion power plant which is water cooled and uses lithium-lead for tritium breeding. For the safety assessment of this design we have studied an accident sequence which starts from a loss or coolant flow then leads to first wall breach and pressurisation of the vacuum vessel. Simulations have revealed strong pressure transients which can be alleviated by design changes. One goal is to verify the adequacy of the containment design: it remains intact at least 14 h without any mitigating efforts. Estimates for radioactive releases are obtained. (author)

2003-08-25

482

Leak sealing on ancillary cooling circuits of CANDU reactors  

International Nuclear Information System (INIS)

This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.

1992-11-22

483

Heating and cooling  

Energy Technology Data Exchange (ETDEWEB)

Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.

1998-05-01

484

Fast starting cold shield cooling circuit for superconducting generators  

Energy Technology Data Exchange (ETDEWEB)

An apparatus is provided for rapidly restarting the flow of coolant through the cold electromagnetic shield of a superconducting rotor following a thermal transient episode. A vortex diode inhibits coolant flow in the undesirable reverse direction and encourages the reestablishment of a normal thermosyphon cooling loop flow quickly following the termination of a thermal transient such as that caused by transmission line faults. The present invention requires no moving parts and may therefore be permanently sealed in the superconducting rotor without risk of costly repair efforts caused by components failure.

1982-12-21

485

Experimental study of beam optics and energy recovery for high-energy electron cooling device  

International Nuclear Information System (INIS)

The feasibility of a high-energy electron cooling device has been studied through tests on a prototype of the electron device. The apparatus consists of a pulsed ((20-60) keV, 2#mu#s) electron gun, a drift region 1 m long and of a depressed collector for recovering the electron energy. Tests on beam optics and energy recovery have been performed, a high-energy recovery efficiency has been attained. Experimental results are discussed in this paper.

486

Development of commercial high temperature gas-cooled reactor in China  

Energy Technology Data Exchange (ETDEWEB)

The high temperature gas-cooled test reactor HTR-10 achieved the first criticality in last December in Institute of Nuclear Energy Technology of Tsinghua University in Beijing. Fuji Electric and Nissho Iwai have a cooperative information exchange agreement on the commercialization of the HTGRs with INET, and held an information exchange meeting in last March in INET. INET has started a study on the modification of the HTR-10 to couple with gas turbine system and a pre-feasibility study on the commercial HTGR under the cooperation with China State Power Company. The experiences and abilities of INET in the field of the HTGR and the aggressive plan for commercialization of the HTGR in China are summarized and discussed. (author)

2001-07-01

487

Development of a helium-cooled divertor concept: design-related requirements on materials and fabrication technology  

International Nuclear Information System (INIS)

Within the framework of the EU power plant conceptual study (PPCS), a modular He-cooled divertor concept with integrated pin array (HEMP) is being developed at the Forschungszentrum Karlsruhe. The design goal is to achieve a high heat flux of at least about 10-15 MW/m"2, which is proposed for a near-term reactor model like DEMO. The development and optimization of the divertor concept require a close link between the main issues: design, analyses, materials and fabrication technology, and experiments with feedbacks between them to be accounted for. Design-specific requirements on materials and fabrication issues will be discussed.

2004-08-01

488

Deterministic loading of individual atoms to a high-finesse optical cavity  

CERN Document Server

Individual laser cooled atoms are delivered on demand from a single atom magneto-optic trap to a high-finesse optical cavity using an atom conveyor. Strong coupling of the atom with the cavity field allows simultaneous cooling and detection of individual atoms for time scales exceeding 15 s. The single atom scatter rate is studied as a function of probe-cavity detuning and probe Rabi frequency, and the experimental results are in good agreement with theoretical predictions. We demonstrate the ability to manipulate the position of a single atom relative to the cavity mode with excellent control and reproducibility.

2007-01-01

489

Cogeneration and beyond: The need and opportunity for high efficiency, renewable community energy systems  

International Nuclear Information System (INIS)

The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.

2007-10-15

490

BNES materials conference a status review of alloy 800  

International Nuclear Information System (INIS)

Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).

491

Thermal performance of phase change wallboard for residential cooling application  

Energy Technology Data Exchange (ETDEWEB)

Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the ...

1997-04-01

492

Natural convection cooling of a vertical channel  

International Nuclear Information System (INIS)

An experimental program has been conducted to determine the feasibility of natural convection cooling of a reactor following a beyond-design-based accident. The particular application under consideration was the heavy-water new production reactor. The questions to be resolved include the verification that a natural convection cooling pattern would be established and the determination of the power limit for which convective cooling will occur for a significant period of time. In the experiment, the reactor configuration was simulated using small-diameter vertical heated tubes in parallel with a large-diameter bypass line. Following a loss-of-flow event, the flow in the bypass line will reverse direction and pass through the heated channel by means of natural convection. If, however, the channel power is too high, void formation will block the channel and prevent the reverse flow pattern from occurring. The test procedure ...

1993-11-14

493

Biological Research for Radiation Protection  

International Nuclear Information System (INIS)

The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect ...

494

Synchrotron radiation from electron beams in plasma-focusing channels.  

Science.gov (United States)

Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron distribution. This leads to a ...

2002-05-20

495

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and ...

1986-01-01

496

Radiation hardening of smart electronics  

International Nuclear Information System (INIS)

Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and ...

497

Ionizing radiation effect on sealant properties  

International Nuclear Information System (INIS)

Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.