International Nuclear Information System (INIS)
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the ...
1984-06-01
Concepts in radiation protection
International Nuclear Information System (INIS)
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for ...
1996-01-01
Factors affecting birth weight in sheep: maternal environment
UK PubMed Central (United Kingdom)
Knowledge of factors affecting variation in birth weight is especially important given the relationship of birth weight to neonatal and adult health. The present study utilises two large contemporary...Full Text Available
2007-01-01
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...
1991-11-01
Electron scattering from atoms in the presence of a laser field. II
In the first paper of this series a formal theory of atomic scattering of electrons in the presence of an intense electromagnetic field was given. Cross sections, near the forward direction, between atomic states (modified by the laser) were obtained. However, it was assumed that the atom could not emit spontaneous radiation. In this paper the effect of spontaneous radiation is included, and it is shown that in most cases the measured cross section will be a weighted average of the two different cross sections starting from the two different initial states which are those atomic states resonantly linked by the laser. The Born approximation for the scattering is obtained, and it is shown that for the simplest description of the spontaneous radiation field the effect of the laser on the cross sections is simply to multiply them by a factor which depends upon the laser detuning. (AIP)
1976-10-01
Radiation induced micrencephaly in guinea pigs
International Nuclear Information System (INIS)
A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays ...
2006-04-20
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...
1990-10-01
Bevacizumab as a treatment option for radiation-induced cerebral necrosis
International Nuclear Information System (INIS)
Radiation necrosis of normal CNS tissue represents one of the main risk factors of brain irradiation, occurring more frequently and earlier at higher total doses and higher doses per fraction. At present, it is believed that the necrosis results due to increasing capillary permeability caused by cytokine release leading to extracellular edema. This process is sustained by endothelial dysfunction, tissue hypoxia, and subsequent necrosis. Consequently, blocking the vascular endothelial growth factor (VEGF) at an early stage could be an option to reduce the development of radiation necrosis by decreasing the vascular permeability. This might help to reverse the pathological mechanisms, improve the symptoms and prevent further progression. A patient with radiation-induced necrosis was treated with an anti-VEGF antibody (bevacizumab), in whom neurologic signs and symptoms improved in ...
2011-02-01
Employment of /sup 203/Pb isotoic solution without a carrier for erythrocyte tracing
Energy Technology Data Exchange (ETDEWEB)
Possibilities of applying the Pb/sup 203/ isotonic solution without a carrier as a label of blood erythrocytes, are found. There is a number of advantages in the Pb/sup 203/ isotonic solution without a carrier, such as a high label efficiency (above 95%), a short half-life (52 hours), and a low radiation dose. These factors prove to be favourable as compared with Cr/sup 51/ widely used for these purposes. Besides, of all preparations used up to now to treat erythrocytes and to scan the spleen, it is only in the case of Pb/sup 203/ isotonic solution without a carrier that no weight amounts of chemical substances do not enter the organism.
1981-08-01
International Nuclear Information System (INIS)
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs ...
2004-07-01
Population doses from beam-therapy in Japan, 1978, 3
International Nuclear Information System (INIS)
As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; ...
1981-01-01
UK PubMed Central (United Kingdom)
BackgroundIn Africa low birth weight (LBW) (<2500 g), is the strongest determinant of infant morbidity and mortality. The aim of this study was to quantify the effect of...Full Text Available
Consanguinity and fetal growth in Pakistani Moslems.
UK PubMed Central (United Kingdom)
There is conflicting evidence about the effect of parental consanguinity on fetal growth. Previous studies have not always allowed for other factors that are known to affect birth weight, in particular,...Full Text Available
1987-03-01
International Nuclear Information System (INIS)
Decommissioning of radiological and nuclear installations is for this century the new challenge. One of the performance criteria is the reduction of total quantities of radioactive materials (liquid or solid) arising from dismantling and decontamination of radiological and nuclear installations. In this work we present a new application of the water soluble polymers used as: - flocculation agents in treatment and conditioning process within the management of radioactive liquid materials; - strippable coatings on solid materials based on the water soluble polymers. The parameters of water soluble polymers made in our Institute by radiation processing have been analysed, namely the molecular average weight, composition, and efficiency of utilization of these polymeric materials as well as the content of ash, additives, decontamination factor, consumption per surfaces/liter, corrosion aspects, compatibility with various ...
2003-10-20
Optimization of a parity of brake forces of automobiles in view of a bias of road
International Nuclear Information System (INIS)
In clause it is shown a method optimization of brake of forces in view of a bias road it is established, that in mountain conditions of loss of coupling weight of automobiles than 2-3 times concerning flat conditions therma are more. The degree of use of coupling weight in result use of a regulator of brake forces very much increases also efficiency of brake systems such a kind of automobiles is provided with definition of optimum factor of coupling at which value of loss of coupling weight is provided minimal
Pregravid BMI is associated with dietary restraint and psychosocial factors during pregnancy1
UK PubMed Central (United Kingdom)
The objective was to investigate the association of pregravid weight status, dietary restraint and psychosocial factors during pregnancy. We used data from the Pregnancy, Infection and Nutrition...Full Text Available
2009-03-01
UK PubMed Central (United Kingdom)
The objectives of this study were to examine the association between dietary factors and underweight and overweight adult Vietnamese living in the rural areas of Vietnam. A cross-sectional study of...Full Text Available
2010-06-01
The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627
2011-01-01
uv photobiology: postreplication repair. [Escherichia coli, synchrotron radiation
The following topics are discussed: insertion of incorrect bases in DNA; ability of DNA polymerase to copy uv-irradiated DNA; role of enzymes in repair of DNA; effects of uv radiation on molecular weight of DNA; photoreactivation; repair of DNA in Escherichia coli and xp cells following uv radiation; and synchrotron radiation studies on DNA repair. (HLW)
1978-01-01
Sound transmission loss of composite sandwich panels
Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, ...
2009-01-01
Numerical analysis of methane-air combustion considering radiation effect
Energy Technology Data Exchange (ETDEWEB)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation ...
2008-12-15
Numerical analysis of methane-air combustion considering radiation effect
International Nuclear Information System (INIS)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect ...
2008-12-01
Evaluation of radiation resistance of cable connector material
Energy Technology Data Exchange (ETDEWEB)
Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.
2002-10-01
Energy Technology Data Exchange (ETDEWEB)
Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)
1990-02-15
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...
2008-10-01
Strength functions of primary transitions following thermal neutron capture in strontium
Energy Technology Data Exchange (ETDEWEB)
The primary E1, M1 and E2 ..gamma..-radiation in /sup 87,88,89/Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, ..gamma..) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for /sup 90/Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models.
1989-04-01
Strength functions of primary transitions following thermal neutron capture in strontium
International Nuclear Information System (INIS)
The primary E1, M1 and E2 #gamma#-radiation in "8"7","8"8","8"9Sr observed after thermal neutron capture was compared with the predictions of single particle and giant resonance models. The nuclei feature a wide range of neutron binding energies between 6.3 and 11.1 MeV, which makes a 5.5 MeV spectrum of primary transition energies available for investigation. The (n, #gamma#) reaction was used to estimate the parameters of the spin-flip M1 giant resonance in strontium. The total energy weighted M1 strength of this resonance exceeds the results of shell model and random phase approximation calculations for "9"0Zr by a factor of 3-4. The E1 strengths were found to agree with the established giant dipole resonance model. The few data on primary E2 transitions do not allow to differentiate between the giant quadrupole resonance and the single particle models. (orig.).
Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes
International Nuclear Information System (INIS)
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. ...
1982-06-25
International Nuclear Information System (INIS)
Some of the Indian pressurized heavy water reactors (PHWRs) which use Stellite balls in the ball and screw mechanism of the adjustor rod drive mechanism in the moderator circuit have encountered high radiation fields in the moderator system due to "6"0Co. Release of particulate Stellite is responsible for the hotspots in addition to the general uniform contamination of internal surfaces with "6"0Co. Extensive laboratory studies have shown that it is possible to dissolve these Stellite particles by adopting a three-step redox process with permanganic acid as the oxidizing agent. These investigations with inactive Stellite in powder form helped to optimize the process conditions. Permanganic acid was found to have the highest dissolution efficiency as compared to alkaline and nitric acid permanganate. The susceptibility of Stellite to corrode or dissolve was found to depend on the concentration of the permanganate, pH and temperature of the process and microstructure ...
2011-06-01
Structural and functional aspects of radiation adrenalopathy
Energy Technology Data Exchange (ETDEWEB)
As part of a combined study of the responses of the mouse adrenal gland and kidney to X-irradiation, the weight of adrenal glands, the relative volumes of the cortex and medulla and the aldosterone output were measured at predetermined times after irradiation of the left organs only.
1986-01-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
Energy Technology Data Exchange (ETDEWEB)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube ...
2003-12-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
International Nuclear Information System (INIS)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings ...
2003-12-01
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
International Nuclear Information System (INIS)
Effect of single and chronic irradiation on factors of hamsters natural immunity such as complement, lysozyme and antibodies in norm and in the cestode invasion has been investigated. Significant phase changes in the complement activity level, lysozyme content and specific antibodies tite have been shown to occur in hamster blood under the influence of ionizing radiation. Cestode invasion in irradiated host organism increases the negative effect of ionizing radiation on the hamster immyne system.
1994-01-01
International Nuclear Information System (INIS)
The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main ...
1976-01-01
Fuzzy performance measurement of a supply chain in manufacturing companies
British Library Electronic Table of Contents (United Kingdom)
This paper is aimed to present a fuzzy decision making approach to deal with the performance measurement in supply chain systems. In the manufacturing environment, performance measurement is based on different quantitative and qualitative factors. Some of these factors may have a larger effect on the performance measure than others. Units of measure of the quantitative factors are different such as time, money, percentage, ratio, and counts. Thus, this paper presents a performance measurement approach based on fuzzy set theory and the pair-wise comparison of Analytical Hierarchy Process (AHP), which ensures the consistency of the designer's assignments of importance of one factor over another to find the weight of each of the manufacturing activity in the departmental organization. In the ...
2011-01-01
Body and brain development following exposure to "6"0Co #gamma#-irradiation during pregnancy in mice
International Nuclear Information System (INIS)
We studied the dose-response effects of #gamma#-irradiation on the weight gains of the body and the brain in ICR mice exposed to various doses of "6"0Co #gamma#-irradiation ranging from 0 to 1.5 Gy on day 13 of pregnancy (E13). We found that 0.5 Gy #gamma#-irradiation caused a significant reduction in brain weight but not in body weight among 6-week-old mice. Higher doses (1.0, 1.5 Gy) seriously inhibited body and brain development, resulting in significantly low weights at 6 weeks of age. A significantly lower brain weight among fetuses exposed to 1.5 Gy was found as early as 24 hours after exposure, while significant reductions in the body weight of these same fetuses appeared 3 days after exposure. The effects of radiation on brain and body development were similar for both males and females. (author).
Inhibited spontaneous emission by a Rydberg atom
Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.
1985-11-11
Induction of tumors by screening mammography
International Nuclear Information System (INIS)
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
1983-01-01
EPR dosimetry in chemically treated fingernails
UK PubMed Central (United Kingdom)
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
2007-08-01
Preconcentration and decontamination in radioanalysis
International Nuclear Information System (INIS)
The scope of radioanalysis can be enlarged substantially by preconcentration. The minimal concentration factor required depends on the concentration to be determined, the limit of determination of the analytical technique and the maximal acceptable sample-weight. Simultaneously, the preconcentration step may cause a decontamination. In post-irradiation chemistry this is usually the crucial parameter. The present paper proposes the classification of (pre-) concentration techniques by the relation between the concentration-factor X and the decontamination-factor Y. In addition, three other criteria here are used to judge the applicability in combination with the analytical technique chosen. They stem from the minimal representative and the maximal acceptable sample-weights and the maximal acceptable dose-rate. The features of a particular combination of (pre-) concentration and ...
The effect of perinatal "6"0Co gamma radiation on brain weight in beagles
International Nuclear Information System (INIS)
Beagle dogs were given single, whole-body "6"0Co gamma-radiation exposures at one of three prenatal (8, 28, or 55 days postcoitus) or three postnatal (2, 70, or 365 days postpartum) ages to evaluate the relative radiosensitivity of various stages of brain development. A total of 387 dogs received mean doses ranging from 0.16 to 3.83 Gy, and 120 dogs were sham-irradiated. Groups of dogs were sacrificed at preselected times from 70 days to 11 years of age. Brain weight decreased significantly with increasing dose in dogs irradiated at 28 or 55 days postcoitus or at 2 days postpartum. Irradiations at 28 days postcoitus were dramatically more effective in causing a reduction in brain weight than those at 55 days postcoitus or 2 days postpartum. Among dogs given 1.0 Gy or more and followed for up to 4 years, there was a radiation effect evident at all three sensitive exposure ages. Among dogs given lower ...
Medical irradiation and the use of the 'effective dose equivalent' concept
International Nuclear Information System (INIS)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also ...
1980-03-01
Standard radiation monitoring at Sendai nuclear power station
International Nuclear Information System (INIS)
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
Cellular Sources of Transforming Growth Factor-? Isoforms in Early and Chronic Radiation Enteropathy
UK PubMed Central (United Kingdom)
The three mammalian transforming growth factor (TGF)-β isoforms (TGF-β1, TGF-β2, and TGF-β3) differ in their putative roles in radiation-induced fibrosis in intestine...Full Text Available
1998-11-01
Radiative properties of a solar cavity receiver/reactor with quartz window
British Library Electronic Table of Contents (United Kingdom)
An energy transfer and conversion model for high-temperature solar cavity receivers has been developed using the transport behaviour of solar radiation as described by the spectral radiative exchange factors. A Monte-Carlo ray-tracing method coupled with optical properties was adopted, to predict radiation characteristics of the solar collector system by calculating radiative exchange factors. A cavity receiver with a plano-convexo quartz window was proposed, based upon the directional characteristics of the focal flux and the redistribution effect of the quartz window. Parametric studies on the windowed receiver provided a more uniform flux distribution, higher efficiency and lower loss than the windowless receivers. The predicted results serve as a design reference for the solar receiver...
2011-01-01
Modulating factors in the expression of radiation-induced oncogenic transformation
Energy Technology Data Exchange (ETDEWEB)
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, ...
1990-08-01
Modulating factors in the expression of radiation-induced oncogenic transformation
International Nuclear Information System (INIS)
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, ...
1990-01-01
Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice
International Nuclear Information System (INIS)
A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse ...
New Radiation Stable and Long-Lived Plastic Scintillators
International Nuclear Information System (INIS)
A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic scintillators is residual ...
1993-11-15
International Nuclear Information System (INIS)
For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant ...
1980-01-01
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
International Nuclear Information System (INIS)
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous lung/water, the lung ...
2004-02-01
Resistance of radiation-induced tropical wood-polymer composites to fungal degradation
Energy Technology Data Exchange (ETDEWEB)
The resistance of six tropical hardwoods to fungal degradation by two wild-type strains of Phanerochaete chrysosporium Burdsall was investigated using vermiculite burial and wood-block weight loss techniques. Radiation-induced wood-polymer composites (WPC), based on two hardwoods Ramin and Rubberwood with methyl methacrylate, were prepared, and samples were also exposed to the wood-rotting fungus. A significant improvement in resistance to fungal decay was observed in the WPC. Scanning-electron micrographs of the two woods and their composites after fungal degradation are presented and discussed.
1987-01-01
Radiation induced synthesis of low molecular weight of PTFE and their crosslinking in acetone medium
International Nuclear Information System (INIS)
Polytetrafluoroethylene was obtained by radiation induced polymerization of tetrafluoroethylene in acetone at 195 K. An average diameter of the products was very small compared with commercial one; it was about 0.3 micro-meters. The yield was reached to 100% with a dose of 4 kGy. The crystallinity of the products is decreasing with increasing dose. The products become amorphous, for higher irradiation doses. It was found that PTFE obtained by irradiation of TFE in acetone at 195 K has branching structure. This was demonstrated by means of "1"9F MAS NMR. (Author)
2007-09-03
Numerical integration of the Feynman Path Integral for radiative transport
International Nuclear Information System (INIS)
The radiative transport problem is cast in integral form using a transport kernel. The transport kernel has an explicit representation in terms of a Feynman Path Integral over all paths between selected points in a volume. This representation is setup in detail. Numerical evaluation of this Path Integral is formulated with a Frenet-Serret based procedure for generating valid random paths, and with a numerical evaluation of the weight for each valid path. Very early sanity checks of a numerical implementation are reported. Approaches to optimization are identified. (authors)
2009-05-03
Technological press on the environment: comparison of the radiation and conventional processing
International Nuclear Information System (INIS)
Transformation of row material to the consumption goods proceeds by the succession of various technologies using energy and chemicals. Relative contribution of both factors is broadly varied. The chemical reagents are not per se consumption goods and their production is auxiliary. Maximal usage of chemicals is observed in conventional technologies. On the contrary radiation technology does not need chemicals. Therefore usage of radiation technology leads to diminution of chemical processing and hence to the attenuation of the technological press on the environment. As examples the radiation technological methods in conversion of coal and biomass are considered. (author).
1994-09-11
Radiation therapy in the treatment of hilar cholangiocarcinoma
International Nuclear Information System (INIS)
The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation therapy. The propective randomized clinical study is needed for further investigation in the role of combined ...
2007-10-01
Radiation hardening of smart electronics
International Nuclear Information System (INIS)
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness ...
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
1984-11-08
The malignancy significant dose from external beam radiotherapy
International Nuclear Information System (INIS)
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
1987-01-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
Major factors that contribute to maximized impact resistance of semicrystalline engineering polymers include increased matrix molecular weight, minimal rubber glass-transition temperature, and optimal rubber-particle size, which depends on matrix type. Additional constraints are posed by the limitations of available materials and commercial requirements. Expanding the understanding of impact-modified crystalline engineering polymers will further extend their property ranges and utility. This chapter describes the phenomenology of certain factors, illustrates a new technique to measure rubber particle size, and contrasts the fracture mechanisms of poly(butylene terephthalate), nylon 66, and polyacetal. 49 refs., 24 figs.
1993-12-31
A two-cycle process for enhanced actinide separation from radioactive liquid wastes
Energy Technology Data Exchange (ETDEWEB)
A two-cycle process using O{Phi}CMPO and HDEHP as extractants to achieve an alpha decontamination factor of HLLW greater than 10{sup 3} together with a reduction of the lanthanides/americium weight ratio by a factor of about 200 is considered. Experimentally measured distribution ratios have been employed as input data of a suitable computer code to define operating conditions and M/S stage numbers of a process flow-sheet able to meet the above-mentioned objectives.
1996-09-01
Energy Technology Data Exchange (ETDEWEB)
It is not known whether body weight alone can adjust for the volume of liver in the calculation of the chelating dose in {beta}-thalassaemia major patients, who frequently have iron overload and hepatitis. The hypothesis is that liver volume in children and adolescents suffering from {beta}-thalassaemia major is affected by ferritin level and liver function. Thirty-five {beta}-thalassaemia major patients aged 7-18 years and 35 age- and sex-matched controls had liver volume measured by MRI. Serum alanine aminotransferase (ALT) and ferritin levels were obtained in the thalassaemia major patients. Body weight explained 65 and 86% of the change in liver volume in {beta}-thalassaemia major patients and age-matched control subjects, respectively. Liver volume/kilogram body weight was significantly higher (P<0.001) in thalassaemia major patients than in control subjects. There was a significant correlation between ALT level ...
2005-02-01
Method for processing statistical information concerning sucker-rod pump unit operations
Energy Technology Data Exchange (ETDEWEB)
The authors propose an integrated indicator of pump-rod couplings that allows both the couplings and the pump operations to be appraised according to the given formula. (Formula provided). The dynamic relationships of rod operations were determined with nomographs. These relationships involve such factors as: the type and size of the sucker-rod string; the pressure load at the equalizer head and its correlation to threshold pressure at pump discharge; pump diameter; the rod weight and construction; and integral reliability indicators.
1982-01-01
Caesium clocks. Status and research activities
International Nuclear Information System (INIS)
Thirty years ago, in 1967, the new definition of the second based on a quantum phenomenon, the hyperfine splitting of the groundstate of the "1"3"3Cs atom, was passed by the 13th General Conference on Weight and Measure. What followed was a fascinating improvement of the performance of caesium clocks which is still pursued. Their total uncertainty could be reduced, until 1995, by 4 orders of magnitude. With the development of the so-called fountain clocks, another factor of ten is within reach. (orig.)
1998-02-01
Measurement of liquid nitrogen level by radiation
Energy Technology Data Exchange (ETDEWEB)
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
1995-07-01
International Nuclear Information System (INIS)
Efforts are being made to determine a gamma radiation dose for mortality of third-instar larvae of Anastrepha fraterculus which infest mangos of the Haden variety of 400 g weight. Four radiation treatments were tested: 0.4 kGy, 0.6 kGy, 0.8 kGy and 1.0 kGy. Using as a criterium for mortality the interruption of the biological cycle between larva and pupa, the following results were achieved: 49.61%, 63.33%, 74.86% and 90.72%. The percentages obtained have been corrected using the Abbot formula. When the criterium was based on no adult emergence, 100% mortality was achieved for the four treatments. (author)
1999-01-01
Preparation of polyester/gypsum/composite using gamma radiation, and its radiation stability
Energy Technology Data Exchange (ETDEWEB)
Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of oxygen. Increasing the irradiation dose leads to an enhancement of the compression strength of the pure ...
2005-06-01
UK PubMed Central (United Kingdom)
Purpose: This paper reviews and reassesses the internationally accepted niches or ‘targets’ in bone marrow that are sensitive to the induction of leukaemia and primary...Full Text Available
2011-04-01
International Nuclear Information System (INIS)
The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and ...
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
Radiation inactivation and sedimentation equilibrium analysis were used to determine the functional and physical size of the chicken hepatic membrane receptor that binds N-acetylglucosamine-terminated glycoproteins. Purified plasma membranes from chicken liver were irradiated with high energy electrons and assayed for 125I-agalactoorosomucoid binding. Increasing the dose of ionizing radiation resulted in a monoexponential decay in binding activity due to a progressive loss of binding sites. The molecular mass of the chicken lectin, determined in situ by target analysis, was 69,000 +/- 9,000 Da. When the same irradiated membranes were solubilized in Brij 58 and assayed, the binding protein exhibited a target size of 62,000 +/- 4,000 Da; in Triton X-100, the functional size of the receptor was 85,000 +/- 10,000 Da. Sedimentation equilibrium measurements of the purified binding protein yielded a lower limit molecular weight of ...
1990-03-05
Energy Technology Data Exchange (ETDEWEB)
It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.
1995-09-01
Health risks arising from ionizing radiation and chemical pollutants
International Nuclear Information System (INIS)
In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and regulations specified ...
1979-10-03
[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].
Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295
1986-01-01
Development of a computerized portal verification scheme for pelvic treatment fields
International Nuclear Information System (INIS)
Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied to identify the ...
1996-09-01
Self-Consistent Asset Pricing Models
We discuss the foundations of factor or regression models in the light of the self-consistency condition that the market portfolio (and more generally the risk factors) is (are) constituted of the assets whose returns it is (they are) supposed to explain. As already reported in several articles, self-consistency implies correlations between the return disturbances. As a consequence, the alpha's and beta's of the factor model are unobservable. Self-consistency leads to renormalized beta's with zero effective alpha's, which are observable with standard OLS regressions. Analytical derivations and numerical simulations show that, for arbitrary choices of the proxy which are different from the true market portfolio, a modified linear regression holds with a non-zero value $\\alpha_i$ at the origin between an asset $i$'s return and the proxy's return. Self-consistency also introduces ``orthogonality'' and ``normality'' conditions ...
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
This paper presents the first report of multiple anthelmintic resistance in the gastrointestinal nematodes of goats and its possible contributory factors in an irrigated area (Pakistan). A total of 18 privately owned Beetal goat flocks were selected in order to determine the anthelmintic resistance against commonly used anthelmintics. Forty to 48 animals from each flock were selected according to their weight and egg count. The three anthelmintics viz., oxfendazole, levamisole and ivermectin, were given to three groups at manufacturer's recommended dose while one group was kept as untreated control. Anthelmintic resistance was determined through faecal egg count reduction and egg hatch tests while assessment of the contributory factors of anthelmintic resistance was measured through the ru...
2010-01-01
Applications or radiation polymerization hardening to composites
International Nuclear Information System (INIS)
Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at high dose rate cannot ...
1976-01-01
miR-9 and let-7g enhance the sensitivity to ionizing radiation by suppression of NF?B1
UK PubMed Central (United Kingdom)
The activation of nuclear factor-kappa B1 (NFκB1) in cancer cells may confer resistance to ionizing radiation (IR). To enhance the therapeutic efficiency of IR in lung cancer, we screened for...Full Text Available
2011-05-31
Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy
International Nuclear Information System (INIS)
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
Rest life time management of Kozloduy NPPP Unit 3 and 4
International Nuclear Information System (INIS)
The radiation life time of reactor pressure vessel (RPV) is the most important limiting factor for the term of exploitation of the whole power unit. The main degradation mechanism of RPV metal is the neutron induced embrittlement. Processes of radiation ageing running in RPV metal lead to fracture toughness decrease and to increased probability of brittle fracture of the vessel under thermal shocks. This explains the importance of RPV integrity assessment and rest life time management
2002-11-04
International Nuclear Information System (INIS)
From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).
1984-01-01
Radiation hardening of semiconductor parts
International Nuclear Information System (INIS)
This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.
Projection techniques in diagnostic radiography discussed with regard to required dose
International Nuclear Information System (INIS)
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
1990-09-01
Effects of chronic ingestion of tritiated water on prenatal brain development
International Nuclear Information System (INIS)
In view of the anticipated increased use of atomic energy in industry, the possible long-term effects of chronic radiation exposure were studied in five generations of rats. Female rats (F_0) were given tritiated drinking water ("3HOH;3#mu#Ci/ml) from adolescence (60 days) until and throughout pregnancy. A separate study showed that the maximum radioactivity in the urine is reached in 30 days, and in the blood in 42 days. In the newborns, the highest specific activity was in the nucleic acid fraction, but total radioactivity was mainly due to the water (body fluids) compartment. No signs of radiation illness or increase in cataract formation in the mothers were observed. The food and water intake and body weight changes before pregnancy were normal. The course and the outcome of pregnancy were also normal. However, 60% of the newborns (F_1) exhibited hematomas, edemas, and subdural hemorrhages, which disappeared at 30 days ...
British Library Electronic Table of Contents (United Kingdom)
Abstract Tumor necrosis factor (TNF)- is a pro-inflammatory cytokine associated with psoriasis pathogenesis. Anti-TNF- therapies are effective in psoriasis. A significant weight gain has been reported in patients treated with anti-TNF- agents. The aim of the present study was to evaluate the body composition changes in psoriatic patients receiving anti-TNF- therapies according with disease phenotype. Forty patients affected with psoriasis were followed up for 24 weeks and divided into two groups: psoriasis vulgaris (PsO) and psoriatic arthritis (PsA). Anthropometric, blood biochemical, body composition parameters, resting metabolic rate, and disease activity indexes were measured at baseline and at week 24. After 24 weeks of anti-TNF- administration, the disease activity indexes and concen...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Magnesium alloys show a high specific strength and are therefore increasingly used for light-weight constructions in transportation industry.{sup [1,2]} To predict the behaviour of the material under the influence of cyclic loading it is vital to understand the fatigue behaviour of magnesium alloys. Only when understood properly, it is possible to fully apply the potential weight reduction by using magnesium alloys. A very important aspect in fatigue of magnesium alloys is the influence of a corrosive media and elevated temperatures, of which both are relevant in automotive applications. These two factors tend to have deleterious effects on magnesium alloys and therefore also have to be considered in investigations on the fatigue behaviour of magnesium alloys. (Abstract Copyright [2004], Wiley Periodicals, Inc.)
2004-05-01
Assessment of Low Quantitative Ultrasound Values of Calcaneus in Chinese Mainland Women
British Library Electronic Table of Contents (United Kingdom)
Calcaneus quantitative ultrasound (QUS) assessment is a safe and reliable method for evaluating skeletal status. Until now, considerable data have been accumulated on the distribution of QUS in Caucasian populations, whereas such data are still insufficient in Asian populations, especially in Chinese mainland. The present study aimed to obtain the distribution characteristic of calcaneus QUS in healthy Chinese women, and to further investigate the distribution of low bone mass by QUS stiffness index (SI). This study included 2,498 healthy Chinese females aged 10-87 yr. The QUS exhibited a characteristic mild rise and then fall pattern with increasing age. Age, body height, and weight were significant influencing factors on SI, especially age and weight. The prevalence of osteoporosis detec...
2006-01-01
Radiation risk in computerized tomography (CT)
Energy Technology Data Exchange (ETDEWEB)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as ...
1984-01-01
Radiation risk in computerized tomography (CT)
International Nuclear Information System (INIS)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as ...
1984-01-01
Radiation risk in computerized tomography (CT)
International Nuclear Information System (INIS)
The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as ...
Assessment and control of fetal exposure
Energy Technology Data Exchange (ETDEWEB)
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose ...
1991-10-01
R46 and pKM101 plasmid-mediated resistance to ionizing radiation in Escherichia coli
International Nuclear Information System (INIS)
The ability of the R46 R factor and its derivative pKM101 to modify sensitivity to "6"0Co #gamma# radiation was studied. In Escherichia coli K12 both plasmids enhanced bacterial survival after "6"0Co #gamma# irradiation. This effect was dependent on recA"+ genotype but not on recB"+, recB"+recC"+, and recF"+ genotypes. 5-Fluorouracil eliminated the R46 R factor from the parent and its rec"- mutant strains. These strains lost not only the antibiotic resistance coded for R46 R factor but their radioresistance as well.
International Nuclear Information System (INIS)
The Moessbauer emission spectrum of "2"4"1Am metal was investigated for influences of radiation self damage. Samples were kept continuously for 230 h at 4.2 K and spectra were taken each 10 to 20 h. No change in f-factor was observed, while the linewidth increased monotonically and reached saturation after approximately 180 h. The original width could be reproduced by a brief warming to room temperature. The increase in width reflects the change in quadrupole interaction due to the creation of lattice defects. The constancy of the f-factor indicates that the basic crystalline structure is retained.
International Nuclear Information System (INIS)
The activity of tyrosine aminotransferase (TAT) in the liver of mice subjected simultaneously to ionizing radiation and to local inflammatory process showed in the first 24 hours of the experiment statistically significant changes resulting from summation of the harmful effects of both factors. In the second 24-hour period an evident tendency was observed for return of a normal circadian rhythm of the enzyme. This points to presence of an endogenous mechanism of suppression of the manifestations of significant desynchronization of the circadian rhythm. The paper contains also a trial of mathematical analysis of changes in TAT activity in the circadian rhythm, a description and analysis or the suppression process, qualitative and quantitative determination of the phenomenon of cumulation of the effects of powerful stress factors acting on the animal organism. The obtained results were compared with the results of ...
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors ...
1995-02-01
Endothelial dysfunction is involved in radiation responses in many normal tissues, including intestine. Endothelium-directed interventions ameliorate intestinal radiation injury (radiation enteropathy) in animal models, and anecdotal reports also suggest a beneficial effect of heparin. This study assessed low molecular weight heparin as an intestinal radiation response modifier. Rats underwent localized small bowel irradiation. Groups of rats were treated with saline, nadroparin (3 mg/kg/d), or a non-anticoagulant heparin (SR80258, 3 mg/kg/d), from 3 days before to 2 weeks after irradiation. The intestinal radiation response was assessed 2 weeks and 6 weeks after irradiation using quantitative histology; morphometry, and cellular and molecular end-points. Compared to vehicle-treated controls, nadroparin significantly exacerbated structural ...
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
This report surveys the possibilities and restrictions of different construction materials for the purpose of the blades of a small stall regulated turbine. For example scaling up, material saving at decreasing of static or dynamic loads, comparisons of global costs based on prices per unit of weight, etc. For the mutual comparison of construction materials for turbine blades the starting point is a stall regulated horizontal axis turbine with a rotor diameter of 16 m and a tipvane speed of about 64 m/s. Short descriptions are given of the materials and of the applied production methods with the resulting blade geometry. The blade skins are dimensionized for storm loads after the optimalization of the blade geometry, needed for the design wind speed, is recorded. The resulting blade skins are mutually compared as for weight, mass inertia and bending stiffness. Also a comparison took place of the resulting reserve factors ...
1988-02-01
Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children
Energy Technology Data Exchange (ETDEWEB)
During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 Gy. Irradiation session was 2 or 3 times per week. In 5 cases, 4 ...
1996-03-01
International Nuclear Information System (INIS)
The development of Callossobruchus chinensis (L.) in different packaging materials were conducted with gram and lentil seeds under control temperature. The highest population rise was recorded in laminated jute bags and the weight loss of gram increased with the increase of the number of insects. A doses of 0.1 kGy inhibit all metamorphic stages of the beetle. The use of appropriate packaging materials can reduce the risk of re infestation in the post-irradiated food items. 9 refs., 1 fig., 2 tables (author).
Microbuckling compression failure of a radiation-induced wood/polymer composite
Energy Technology Data Exchange (ETDEWEB)
A wood/polymer composite was produced by impregnating Ramin wood with methyl methacrylate monomer and subsequently polymerizing it by gamma irradiation. To assess the improvement in compression strength of the wood caused by the polymer impregnation, a microbuckling compression failure mechanism was used to model the compression failure of the composite. Such a mechanism was found to predict a linear relationship between the compression strength and the percentage polymer impregnation (by weight). Uniaxial compression test results at 45({plus minus}5)% and 90({plus minus}5)% relative humidity levels, after being statistically analysed, showed that such a linear relationship was valid for up to 100% polymer impregnation. (author).
1990-01-01
Microbuckling compression failure of a radiation-induced wood/polymer composite
International Nuclear Information System (INIS)
A wood/polymer composite was produced by impregnating Ramin wood with methyl methacrylate monomer and subsequently polymerizing it by gamma irradiation. To assess the improvement in compression strength of the wood caused by the polymer impregnation, a microbuckling compression failure mechanism was used to model the compression failure of the composite. Such a mechanism was found to predict a linear relationship between the compression strength and the percentage polymer impregnation (by weight). Uniaxial compression test results at 45(#+-#5)% and 90(#+-#5)% relative humidity levels, after being statistically analysed, showed that such a linear relationship was valid for up to 100% polymer impregnation. (author).
1990-01-01
Principles of protection: a formal approach for evaluating dose distributions
International Nuclear Information System (INIS)
One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.
2006-03-01
Effect of gamma rays on grafting parameters and liquid retention property of cassava starch-g-PAN
International Nuclear Information System (INIS)
Radiation modification on liquid retention properties of native cassava starch, gelatinized at 85"0C, by graft copolymerization with acrylonitrile was carried out by mutual irradiation to #gamma#-rays. A thin aluminium foil was used to cover the inner wall of the reaction vessel so that the extent of homo polymer could be reduced to be less than 1.6% with a distilled water retention value of 665 g/g of the dry weight of the saponified grafted product. Confirmations of graft copolymerization and saponification reactions were made by the infrared spectrophotometric technique. The combined effect of radiation parameters in terms of an irradiation time and a dose rate to the same total dose on the extent of grafting reaction expressed in terms of grafting parameters which directly influenced liquid retention values was evaluated in conjunction with statistical analysis.
1992-10-20
Radioprotective effects of Liv.52 and tissue-reduced glutathione (GSH) in experimental rats
International Nuclear Information System (INIS)
The radioprotective effects of Liv.52 on tissue-reduced glutathione (GSH) levels were studied in rats. Adult female Sprague Dawley rats were exposed to whole body gamma radiation of 4 Gy and 8 Gy. Prior to radiation exposure, Liv.52 was fed, one ml per rat, daily for 15 days. Three days after radiation exposure, reduced glutathione levels in the liver, spleen, kidney and blood were studied. Liv.52 was beneficial in restoring the spleen weight to body weigh t ratio in the animals of the 4 Gy group. In the spleen and liver, Liv.52 helped to restore reduced glutathione in sub-lethally exposed rats. Blood-reduced glutathione was found to be normal in both groups of experimental rats who received Liv.52. The above results exhibit the radioprotective effects of Liv.52 in relation to tissue-reduced glutathione in experimental rats exposed to sub-lethal doses of radiation. (author). 3 ...
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are ...
1992-10-01
Coherent spontaneous radiation from highly bunched electron beams
International Nuclear Information System (INIS)
Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10"4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques.
1995-08-21
Acceleration of particles in pulsar magnetosphere and the X-ray radiation
The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
2004-01-01
No research has compared expressions of weight bias across different subgroups of obese individuals. This study compared attitudes toward and beliefs about obesity in women with and without binge eating disorder (BED) and examined whether these attitudes are related to psychological factors. Fifty obese women with BED were compared with an age- and body mass index (BMI)-matched group of 50 obese women without BED on a battery of established measures of anti-fat attitudes and beliefs about weight controllability and psychological factors (self-esteem, depression, and eating disorder features). The ageand BMI-matched groups did not differ with respect to beliefs about obesity or attitudes toward obese persons, or in self-esteem or depression. Correlational analyses conducted separately within each group revealed that women with BED who reported more favorable attitudes towards obese persons had higher ...
2010-01-27
Energy Technology Data Exchange (ETDEWEB)
Critics of higher fuel economy standards for vehicles have long argued that improving vehicle fuel economy will require reducing vehicle weight, and that would result in an increase in the number of fatalities from vehicle crashes. Several researchers have estimated that an across-the-board reduction of vehicle weight would reduce passenger safety (Evans 1991; Kahane 1997; U.S. GAO 1994). However, little research has been done on the relationship of vehicle size and fatality rates, independent of weight (see, however, Joksch, Massie, and Pichler 1998). In this report we review previous analyses of the relationship of vehicle weight and safety. We do this to study the opportunities to improve fuel economy in a more sophisticated way than across-the-board mass reduction. The aim is to explore improvements in traffic safety by making selected vehicle groups lighter, and retaining or enlarging selected ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
The US Environmental Protection Agency (EPA) conducted a cost-effectiveness (CE) analysis to estimate the incremental cost of complying with the proposed effluent limitation guidelines (ELGs) for the coastal oil and gas industry (EPA 1995a). EPA`s CE analysis calculates the pounds of each pollutant that would be removed if the chosen discharge option is selected. In 1993, EPA issued final ELGs for the offshore oil and gas industry and published an offshore CE analysis. The chemical characteristics of produced water from the offshore region are essentially the same as those of produced water from the coastal region. It was surprising, therefore, that EPA chose a much longer list of pollutants and generally stricter weighting factors for the coastal CE analysis. This report reviews the data, assumptions, and analyses used in EPA`s coastal CE analysis and identifies alternate data, assumptions, and analyses that could lead to significantly ...
1995-05-01
Concept of malignant significant factor and its applicability for and occupational exposures
International Nuclear Information System (INIS)
In the medical and occupational exposures, there is a tradition to use the genetically significant dose as an index of harm to the population although it only includes the genetical effects from ionizing radiations. A similar significant dose for somatic effects such as radiation leukemogenesis and carcinogenesis should be added to the genetically significant dose in order to approach an index of total harm to the population from medical and occupational exposures. For this purpose, leukemia and malignant significant factors were determined based on the induction of malignant diseases including leukemia for the atomic bombs in Hiroshima and Nagasaki and the life expectancy of individuals subject to medical examinations or treatments as well as radiation workers, taking account of the possibility of their deaths due to other diseases or accidents during a latent period of malignant diseases. The ...
1980-01-01
Effective numbers of multiquark fluctons in nuclei
Energy Technology Data Exchange (ETDEWEB)
A technique for calculation of the total weight of quark clusters-fluctons: in nuclei is developed. Blokhintsev's formula is justified microscopically and refined by introduction of spin-charge and quark factors. It is shown that the large values of the correlation radius (R/sub C/approx. =0.75 fm or 1.0 fm) derived from experimental data in various papers using this formula correspond to )similarreverse arrowto)2.5 times smaller internucleon distances in the flucton (0.3--0.4 fm), i.e., the hardness of fluctons is caused by unsuppressed manifestation of hidden color at such distances (the corresponding probabilities are presented)
1987-08-01
Effective numbers of multiquark fluctons in nuclei
International Nuclear Information System (INIS)
A technique for calculation of the total weight of quark clusters-fluctons: in nuclei is developed. Blokhintsev's formula is justified microscopically and refined by introduction of spin-charge and quark factors. It is shown that the large values of the correlation radius (R/sub C/#approx =#0.75 fm or 1.0 fm) derived from experimental data in various papers using this formula correspond to #left brace#similarreverse arrowto#right brace#2.5 times smaller internucleon distances in the flucton (0.3--0.4 fm), i.e., the hardness of fluctons is caused by unsuppressed manifestation of hidden color at such distances (the corresponding probabilities are presented).
Effective numbers of multiquark fluctons in atomic nuclei
International Nuclear Information System (INIS)
A technique is developed for calculation of the total weight of the quark clusters-fluctons in atomic nuclei. The microscopical proof of Blochintsev formula is carried out and its refinement is obtained (spin-charge and quark factors enter the formula). It is shown that high values of the correlation radius (R_c #approx =# 0.75 fm or 1.0 fm in various papers) obtained from the experimental data making use of the above formula correspond to internucleon distances in flucton of 0.3-0.4 fm, which is by a factor of #approx# 2.5 lower. This means that the flucton hardness is due to free manifestation of hidden color at those distances (the appropriate probabilities are presented).
British Library Electronic Table of Contents (United Kingdom)
Aims The aim of this study is to examine the dose?response relationships between age, ?lifestyle factors?? (body mass index, tobacco smoking, sports), and symptomatic knee osteoarthritis in a population-based case?control study. Additionally, the study aims to investigate the mode of interaction between body mass index (BMI) and physical workload (occupational kneeling/squatting and lifting/carrying of loads) with respect to the risk of symptomatic knee osteoarthritis. Methods In five orthopedic clinics and five practices, 295 male patients aged 25?70 with radiographically confirmed knee osteoarthritis associated with chronic complaints were recruited. The control group comprised 327 male control subjects. In a structured personal interview, body weight at different ages, body height, cumu...
2010-01-01
International Nuclear Information System (INIS)
We consider the spin-k/2 XXZ model in the antiferromagnetic regime using the free-field realization of the quantum affine algebra U_q(sl_2) of level k. We give a free-field realization of the type-II q-vertex operator, which describes creation and annihilation of physical particles in the model. By taking a trace of the type-I and type-II q-vertex operators over the irreducible highest-weight representation of U_q(sl_2), we also derive an integral formula for form factors in this model. Investigating the structure of poles, we obtain a residue formula for form factors, which is a lattice analog of the higher-spin extension of Smirnov's formula in the massive integrable quantum field theory. This result as well as the quantum deformation of the Knizhnik-Zamolodchikov equation for form factors shows a deep connection in the mathematical structure of the integrable lattice models and the massive integrable ...
1994-12-01
Ultraviolet radiation in Finland
Energy Technology Data Exchange (ETDEWEB)
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
This report concerns investigations in the title conducted by 8 groups of National Institute of Radiological Sciences (NIRS) during the period of 1998-2000. The groups are for investigation of: Effects of p53 tumor suppressor gene in radiation-induced leukemia, Role of atm-gene in dose rate effect of ionizing radiation, Function of DNA-dependent protein kinase catalytic subunit (DNA-PK{sub cs}), Functional complementation of radiation-sensitive mutant M10 cell line by human XRCC4 cDNA expression, Role of radiation-induced apoptosis in digital defects in embryonic mice, Functional analysis of S-phase specific novel nuclear protein NP95 by gene targeting, Role of chemokine in T cell development and lymphomagenesis, and establishment of production techniques of gene-modified mice using embryonic stem cells for genetic analysis of radiation-sensitive genes. The groups describe summaries ...
2002-03-01
A factor which agglutinated the spores of Ceratocystis fimbriata in the presence of Ca2+ was purified from sweet potato (Ipomea batatas Lam cv. Norin[1]) root. Element composition of the purified factor was as follows; analysis found: C (29.8%), H (3.97%), O (65.34%), N (0.81%): calculated for C43H69O70N1: C (30.02%), H (4.01%), O (65.15%), N (0.81%). The factor was mainly composed of galacturonic acid (53% of dry weight) and contained arabinose, fucose, and unidentified component as minor components. The factor also agglutinated A-, B-, AB-, and O types of human erythrocytes to almost the same degree in the presence of Ca2+. The differential spore-agglutinating activity of the factor depended on the pH of the assay medium; it agglutinated similarly the germinated spores of sweet potato and coffee strains at pH 7.5 and 5.5, whereas it displayed a distinct ...
1982-02-01
International Nuclear Information System (INIS)
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work ...
2006-01-01
Quantum tunnelling for Hawking radiation from a dynamical Black Hole
The paper deals with Hawking radiation related to non-static spherically symmetric black hole. Quantum corrections are incorporated using Hamilton-Jacobi method beyond semi-classical approximation. It is found that different order correction terms satisfy identical differential equation as the semiclassical action and are solved by a typical technique. It has been shown that with proper choice of the proportionality factors, one loop back reaction effect in the space time can be obtained. Finally, using the law of black hole mechanics, a general modified form of the black hole entropy is obtained considering modified Hawking temperature.
2011-01-01
Comparison of Atmospheric Dispersion Models Between PHWR and PWR
International Nuclear Information System (INIS)
The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
A multi-stage, multi-disk type seismic source was developed as a downhole seismic source. The seismic source is an improved version of the downhole seismic source of a system in which an elastic wave is generated by a weight accelerated by restitutive force of a spring striking the upper part of a laminated structure consisted of metal disks and elastic bodies installed in water in a well. Enhancing the vibration exciting efficiency requires impedance radiated from the disks to be increased. The multi-disk structure was adopted because of restrictions on the disk area under the limiting condition of being inside the well. Further limitation has still existed, which led to finally structuring the multi-disk type to a multi-stage construction to increase the radiated impedance. In order to increase average velocity on the radiation surface, mass relationship between the hammer and the anvil was sought so ...
1997-05-27
Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era
International Nuclear Information System (INIS)
Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for ...
2006-02-01
Mira variables - Pulsation, mass loss and evolution
International Nuclear Information System (INIS)
Recent developments in the analysis of Mira atmosphere, the determination of the pulsation mode, the problem of mass loss, and the evolution of the Mira variables are covered. Model atmospheres for Mira variables, including the opacities of the molecules expected in very late M-type atmospheres are discussed. The pulsation constant for Omicron Ceti is evaluated using T(eff) = 2900 + or - 200 K, and it is concluded that Miras are fundamental mode pulsators. The importance of molecular opacity to the driving of mass loss is evaluated, and it is pointed out that the radiation pressure on molecules is not a major factor in driving mass loss from Mira. Mass loss is considered as a factor in the calculations of the periods for Mira variables. 30 refs.
1990-05-28
International Nuclear Information System (INIS)
The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physico-mechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl acrylate (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5 - 20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive ...
1974-12-09
International Nuclear Information System (INIS)
The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physicomechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5-20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence ...
1975-01-01
A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP
International Nuclear Information System (INIS)
Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. Confusions for the inspected tubes may occur from deflection of the manipulators. To reduce the deflections of the manipulators ...
2010-10-01
International Nuclear Information System (INIS)
The purpose of the current study was to evaluate the difference in prognostic factors between stage IB and II uterine cervical carcinoma patients treated with postoperative radiation therapy. Between May 1988 and May 1998, a total of 94 patients including 47 patients with stage IB and 47 patients with stage II uterine cervical carcinoma were treated with postoperative radiation therapy at Tokyo Metropolitan Komagome Hospital. All patients were treated with 10 MV X-rays using an anterior-posterior parallel opposed field which covered the whole pelvis. Fractionation was 2 Gy per day, five fractions per week, to a total dose of 50 Gy. The 5-year overall survival rates of stage IB and II were 89.4% and 79.3%, respectively. In multivariate analysis for all patients, lymph node status, histology, and surgical margin status were recognized as prognostic factors. Limited to stage IB patients, lymph node status ...
Modelling of density limit phenomena in toroidal helical plasmas
Energy Technology Data Exchange (ETDEWEB)
The physics of density limit phenomena in toroidal helical plasmas based on an analytic point model of toroidal plasmas is discussed. The combined mechanism of the transport and radiation loss of energy is analyzed, and the achievable density is derived. A scaling law of the density limit is discussed. The dependence of the critical density on the heating power, magnetic field, plasma size and safety factor in the case of L-mode energy confinement is explained. The dynamic evolution of the plasma energy and radiation loss is discussed. Assuming a simple model of density evolution, of a sudden loss of density if the temperature becomes lower than critical value, then a limit cycle oscillation is shown to occur. A condition that divides the limit cycle oscillation and the complete radiation collapse is discussed. This model seems to explain the density limit oscillation that has been observed on the W7-AS ...
2000-03-01
Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions
Energy Technology Data Exchange (ETDEWEB)
Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).
1992-02-01
Magnetospheric particle acceleration and X-ray emission of pulsars
The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
2007-01-01
International Nuclear Information System (INIS)
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of regulations concerning the execution of X-raying ...
1988-01-01
Design of photocatalytic reactors made easy by considering the photons as immaterial reactants
Energy Technology Data Exchange (ETDEWEB)
While it is quite obvious that photons have an essential role in photochemical and photocatalytic processes, it is not simple to analyse the radiation process. A simple approach is presented on the assumption that photons can be treated as immaterial reactants. It is then possible to evaluate the radiation process in terms of parameters such as conversion, selectivity and yield, which are common in the conventional reaction engineering, and of an additional parameter, a volume efficiency factor, which accounts for the exploitation of the reaction volume as the result of the inevitable attenuation of the radiation in the transport through the participating medium. Attention has also been focused on the validation of kinetic data when, as it is usually done, they are interpreted in terms of volume averages. Finally, guidelines have been prepared to support preliminary phases of analysis and/or design of a ...
2005-10-01
The natural background approach to setting radiation standards
International Nuclear Information System (INIS)
The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent ...
1979-03-09
Light Weight Composite Mirrors for Science Instruments
Light Weight Composite Mirrors for Science Instruments. Composite Optics, Inc. San Diego, CA. INNOVATION. Light weight, large aperture reflectors of graphite ...
Intensification of Harmonic Spontaneous Radiation with a Novel Undulator
We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessive current in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeV electrons taking K < 1, for spontaneous radiation emitted along the axis of the system. The emission at harmonics f > 1 is greatly enhanced for the approximate ...
1998-11-01
Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the ...
2005-11-23
International Nuclear Information System (INIS)
The aim of this study was to evaluate the radioprotective effect of turmeric extract (40 mg/kg body weight) and vitamin E (#alpha# - tocopherol acetate, 400 IU/kg body weight) supplementation on lipid peroxidation, reduced glutathione and antioxidant defense enzymes in various organs like liver, kidney and salivary glands at 24 h in adult Swiss mice. "1"3"1Iodine exposure significantly increased lipid peroxidation in kidney and salivary glands in comparison to control animals. Pre supplementation with turmeric extract for 15 days showed significant lowering of lipid peroxidation in kidney. On the other hand vitamin E pre supplementation showed marked reduction in lipid peroxidation in salivary glands. Reduced glutathione levels decreased significantly in liver after radiation exposure. However, pre supplementation with turmeric extract and vitamin E did not improve glutathione levels in liver. In conclusion we have observed ...
2008-10-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been calculated with REFUGE. The ...
1996-12-31
Fat phobia: measuring, understanding, and changing anti-fat attitudes.
We examined fat phobia, defined as a pathological fear of fatness, by constructing the Fat Phobia Scale, determining its reliability and validity, examining correlates of fat phobia, and using a treatment approach designed to decrease fat phobia. Study 1 describes the development of the Fat Phobia Scale, a 50-item, modified 5-point semantic differential scale. Subjects (974 females and 117 males) completed the scale; factor analysis yielded six factors. Respondents who are average weight, female, younger, have more than a high school education, or are nonmedical professionals are more likely to have fat phobic attitudes. Study 2 examines fat phobic attitudes of women (N = 40) who had negative feelings about their bodies. Subjects completed the Fat Phobia Scale before and after a treatment approach designed to reduce their feelings of responsibility for fatness. Total scores on the Fat Phobia Scale and scores on all six ...
1993-12-01
Postresection villus hyperplasia is a major compensatory mechanism in the short-bowel patient. Substances capable of augmenting postresection mucosal hyperplasia could have therapeutic implications. Human growth hormone (hGH) and human growth hormone releasing factor (hGHRF) stimulate growth of the gastrointestinal tract; however, the diabetogenic actions of growth hormone limit its usefulness in clinical practice. Plerocercoid larvae of the tapeworm Spirometra mansonoides produce an analog of hGH void of diabetogenic side effects. We assessed effects of plerocercoid growth factor (PGF) on mucosal adaptation following 70% proximal jejunoileal resection in young rats. Mucosal weight, DNA, protein, and total sucrase activity per centimeter of bowel were increased in resected PGF-treated animals compared to resected controls. We conclude PGF augments intrinsic postresection mucosal hyperplasia following extensive intestinal ...
1987-11-01
Accelerated aging tests with a resid hydrotreating catalyst
Energy Technology Data Exchange (ETDEWEB)
The deactivation rate of a resid hydrotreating catalyst is determined by a complex set of factors involving both chemical and physical changes in the catalyst structure. The various chemical changes that are associated with resid conversion involve thermal and catalytic steps of relatively large molecular weight species with the overall rates significantly affected by mass transfer limitations. The deposition of coke and the variation in the effective promoter level by the accumulation of metals deposited from the resid are the principal factors governing deactivation. The relative importance of mass transfer restrictions on activity and catalyst deactivation can be observed in studies where the average pore diameter of the catalyst has been varied. Several models have been proposed to characterize the deactivation of resid hydroprocessing catalysts. In this paper, the authors discuss some accelerated aging tests with a ...
1987-04-01
International Nuclear Information System (INIS)
Increased levels of epidermal growth factor receptor have been reported in a variety of tumors, including pulmonary squamous cell carcinomas in man. The purpose of this study was to determine if increased levels of epidermal growth factor (EGFR) were present in lung tumors from Beagle dogs that had been exposed to "2"3"9PuO_2- Using immunohistochemical techniques, sections from 17 lung tumors were examined for the presence of EGFR. Seven of the tumors were strongly positive for EGFR; the remainder of the tumors and the normal lung sections were negative. The positive immunostaining could not be correlated with the histologic phenotype of the tumors. Work is in progress to determine the level of EGFR in preneoplastic, proliferative epithelial foci in the Iung. (author)
1988-12-01
Theory and delivery of health programming in the community: the Pawtucket Heart Health Program.
The Pawtucket Heart Health Program is one of the community studies examining whether population-based efforts to lower cardiovascular risk factors will reduce cardiovascular morbidity and mortality. The Pawtucket Heart Health Program intervention is based on a blend of social learning theory, community organization models, community psychology tenets, and diffusion research. This model allows for multifaceted programs that target individuals, groups, organizations, and the entire community to alter their cardiovascular risk through managing blood pressure, lowering blood cholesterol, quitting smoking, increasing fitness, and maintaining desirable weight levels. A dominant feature of the intervention is the emphasis that it places on volunteers for program delivery. The role of volunteers in providing direct services to help citizens lower their blood pressure and lose weight is highlighted to demonstrate the feasibility and ...
1987-01-01
Theoretical and experimental aspects of supervised learning in artificial neural networks
Energy Technology Data Exchange (ETDEWEB)
The topic of supervised learning within the conceptual framework of artificial neural network (ANN) models is addressed. An ANN is a parallel distributed processing system that consists of many computationally simple processing elements interconnected through uni-directional weighted connections. Such networks, which are roughly patterned after biological nervous systems, have been proposed for use in areas in which the traditional von Neumann computer architecture has been relatively unsuccessful. Learning in these networks is accomplished through the use of algorithms that adjust the values of the connection weights. The work presented here addresses the issue of improving the rate at which ANNs can learn to achieve the mapping of an input pattern to a desired output pattern. The most successful learning algorithms for accomplishing this task are based on gradient descent error minimization techniques. However, the large amount of training ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.
2001-01-15
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
Energy Technology Data Exchange (ETDEWEB)
Population residing in the northern part of the Chelyabinsk oblast and the south eastern part of the Sverdlovsk oblast of Russia affected to accidental exposure since 1957. The territory (East Ural Radioactive Trace - EURT) was contaminated after explosion of container with highly radioactive wastes at the Mayak Production Association. Studies of health effects of exposure in the southern, head part of EURT are conducted in the Ural Research and Practical Center of Radiation Medicine (U.R.P.R.M.). In the 1990's U.R.P.C.R.M. formed a cohort of EURT within Chelyabinsk oblast (14,500 cases and 19,400 external controls). The cohort was followed in 1957-1987 and the results of the study are discussed by Crestinina et al. First results of study on exposure late health effects among rural population in the northern part of the EURT are presented in this paper. Firstly, or the period 1958-2000 a statistically significant increase in cancer mortality associated ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
A polyolefin composition is described comprising: 100 parts by weight of polyolefin, not less than 0.5 part by weight of a polyamide selected from the group consisting of nylon 6 and nylon 66, and from 3 to 30 percent by weight of a novolak based on the weight of the polyamide.
1986-07-15
International Nuclear Information System (INIS)
The outcome was retrospectively examined and prognostic factors were discussed for arterial chemo-infusion therapy (ACT) through an implanted reservoir system and radiation therapy (RT) in patients with unresectable intrahepatic cholangiocarcinoma (CCC). ACT plus RT were conducted to 25 patients (mean age 61.7 y, M/F 12/13, stage III-IVB) during 10 years from 1996 to 2005 with various regimens of cisplatin (CDDP), 5- fluorouracil (FU), epirubicin (FARM), mitomycin C (MMC) plus 39-50 Gy of radiation in a fractionated manner partly involving internal RT (2 cases, 15 Gy) and RT for metastatic bone (1, 25 Gy). The survival rates at 1, 2 and 3 years after ACT+RT were respectively 52.5, 43.7 and 28.1%; total efficacy (PR) was 36% (9/25) at 6 months; and significantly good prognostic factors were found to be female and absence of metastasis remote and/or lymphatic around artery. Authors concluded that ACT+RT ...
2007-11-01
Energy Technology Data Exchange (ETDEWEB)
Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived guides that are consistent with current ...
1988-09-01
Wood-plastic composites using woods native to Iran
International Nuclear Information System (INIS)
Radiation induced polymerization of methylmethacrylate and copolymerization of styrene-acrylonitrile mixture in mamrase Carpinus betulus was carried out by means of #gamma#-ray, under different moisture levels and additives. Under all conditions the degree of polymerization was as high as 60%. No pronounced differences were observed in the kinetics of the polymerization of MMA either with moisture content of wood nor with kind and amount of additives. At high moisture (80% RH) content the dimensional stability of wood-PMMA was increased four fold as compared with untreated wood. The hardness increased about 100% for a weight conversion of monomer of about 30 to 40%. Hardness of this wood-polymer composite is comparable to that of the best noble woods in the world. (author).
1978-10-26
International Nuclear Information System (INIS)
A new in vivo method has been developed for the precise observation of RES activity. Both Escherichia coli endotoxin 100 #mu#g/100 g i.v. (LPS) and radiodetoxified endotoxin 100 #mu#g/100 g body weight i.v. (RD-LPS, TOLERIN) increased the granulopectic activity of RES. The RD-LPS was more effective. The preparation containing trace elements also increased the activity of RES. The treatment consisting of the use of both trace elements and RD-LPS proved to be the most effective. The activity of RES was inversely proportional to various doses of X-ray irradiation (7, 8, 9 Gy). Trace elements and RD-LPS even improved the immunity system of animals having deteriorated RES. (N.T.).
Prevention of death from ingested ruthenium-106 by colectomy
International Nuclear Information System (INIS)
Two dogs were given 3.0 mCi/kg body weight of "1"0"6Ru-"1"0"6Rh and two were given 4.0 mCi/kg. At 5 days after treatment, one dog from each dose level was colectomized. The dog given the larger dose but not surgically treated was killed in extremis due to acute lower bowel injury at 18 days. The other dog, given 3.0 mCi/kg but not surgically treated, was killed in a moribund condition at 145 days after dosing. The rectum had perforated. The colectomized dogs recovered from intestinal injury and showed no radiation damage at the termination of the study.
1977-05-01
Irradiation of human insulin in aqueous solution, first step towards radiosterilization
British Library Electronic Table of Contents (United Kingdom)
The degradation of irradiated human insulin in aqueous solutions was investigated in order to protect the protein against ionizing radiation. The influence of the drug concentration, excipients and irradiation temperature were studied.Aqueous solutions at pH 2 were irradiated by gamma rays or by accelerated electrons. Two different high-performance liquid chromatography (HPLC) methods were used: reverse-phase high-performance liquid chromatography (RP-HPLC)/UV and size exclusion liquid chromatography (SEC/UV) to investigate both the fragmentation and the formation of higher molecular weight proteins.In solution without excipients irradiated at ambient temperature at 10kGy, the loss of human insulin is almost complete. Addition of radio-protecting excipients (free radicals scavengers) and c...
2007-01-01
International Nuclear Information System (INIS)
The possible long-term effects of chronic radiation exposure have been studied. Rats were given tritiated drinking water (3 #mu#Ci/ml) before and during pregnancy and thereafter continuously through five generations. The brains were studied at 30 and 120 days postnatally. Significant decreases in weight and DNA and protein contents of specific parts of the brain were found, the most pronounced decreases being in the diencephalon. The decrease in protein content were more pronounced than the decreases in DNA content; the decreases were also more pronounced at 30 days than at 120 days, and more pronounced in the fith generation than in previous generations.
Chronic irradiation and brain development. Final (4th) progress report
International Nuclear Information System (INIS)
The possible long term effects of chronic radiation exposure have been studied. Rats were given tritiated drinking water (3#mu#Ci/ml) before pregnancy, during pregnancy and threafter, continuously through 5 generations. The brains were studied at 30 and 120 days postnatally. Significant decreases in weight, DNA and protein contents of specific parts of the brain were found, the most pronounced decreases being in the diencephalon. The decreases in protein content were more pronounced than the decreases in DNA content; the decreases were also more pronounced at 30 days than at 120 days, and more pronounced in the fifth generation than in previous generations. An attempt was made to explain these complex phenomena on the basis of known periods of proliferation of various brain cells, damage to mothers themselves in each generation, and damage and repair of nucleic acids caused by radioactivity.
Pros, Cons, and Alternatives to Weight Based Cost Estimating
Many cost estimating tools use weight as a major parameter in projecting the cost. This is often
2011-01-01
A factor produced by plerocercoids of the tapeworm Spirometra mansonoides is similar to human growth hormone (hGH) in that it stimulates body growth, binds to hGH receptors, cross-reacts with anti-hGH antibodies, and has lactogenic and insulin-like activities. The purpose of this study was to determine whether plerocercoid growth factor (PGF) is similar to hGH in expressing diabetogenic activity in the genetically obese (ob/ob) mouse. To determine an effective dose for use in the obese mice, the ability of daily injections of PGF to stimulate growth of phenotypically normal mice of the same strain was assessed in a 10-day weight gain assay. Injections of PGF stimulated a dose-dependent weight gain (r = 0.83) and 25 ng eq/day of PGF stimulated a response not significantly different from that produced by 100 micrograms of bovine growth hormone/day. Diabetogenicity was assessed using fasting blood glucose ...
1989-06-01
Different techniques for measuring radon concentration in a spa environment
International Nuclear Information System (INIS)
In the context of radiation protection for both workers and the population in general, natural sources of radiation, and in particular radon gas and its short-life decay products assume great importance. In particular, workers in thermal spas can easily be exposed to a level of radon radiation and its decay products comparable to those in uranium mines, though often these workers are unaware of the danger. The main source of radon in thermal baths is the thermal water itself, coming as it often does from deep springs, and this can produce high radon concentrations which are left in those areas in which therapy is carried out. Another factor which cannot be overlooked is the radioactive content of thermal mud, often matured for long periods by contact with thermal water. Thermal cures, though varying slightly from site to site, consist principally of mud cures, hydro-therapy and inhalation in various ...
2002-10-08
A study of neutron room scattering at RPCF
International Nuclear Information System (INIS)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, ...
1997-01-05
A study of neutron room scattering at RPCF
Energy Technology Data Exchange (ETDEWEB)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, ...
1996-09-01
UK PubMed Central (United Kingdom)
To obtain the low birth weight (LBW) rate, the very low birth weight (VLBW) rate, and gestational age (GA)-specific birth weight distribution based on a large population in Korea, we collected and analyzed...Full Text Available
2005-04-01
Energy Technology Data Exchange (ETDEWEB)
A singular stress field can occur at the edge of the joint plane in a thermally or mechanically loaded material compound. This stress field was calculated analytically and was compared with the results from the finite element method. If one of the two partners consists of ceramic material, unstable crack spread starting from faults in this strongly stressed area can lead to failure. In linear elastic material, the behaviour of a crack is clearly described by the stress intensity factors. These can be calculated for a known stress distribution in the uncracked structure by the method of the weight function. The corresponding weight functions for surface cracks parallel to the boundary surface were determined with the aid of suitable reference load cases. The effect of the position of the crack in the compound and the elastic constants of the compound are discussed. For examples, the stress intensity ...
1995-03-01
British Library Electronic Table of Contents (United Kingdom)
The effect of phosphonate anion (PHOS) on the corrosion of ordinary steel in simulated cooling water has been studied using weight loss, polarization curves and electrochemical impedance spectroscopy measurements. PHOS was studied in the concentration range from 7.5x10^-^5 to 10^-^3M. The results obtained reveal that PHOS perform excellently as corrosion inhibitor for ordinary steel in simulated cooling water. The inhibition efficiency of PHOS was increased with increasing both its concentration and water circulation velocity. These two factors seem to promote the adsorption of phosphorus and oxygen ions on the metal surface, leading to the formation of a protective layer with a greater charge transfer resistance and lower permeability. The inhibition efficiency decreased slightly with tem...
2010-01-01
Psychometric properties of a scale measuring negative attitudes toward overweight individuals.
This study examined the psychometric properties of the Anti-fat Attitudes Scale (AFAS), a 5-item instrument developed by the authors to measure negative attitudes toward overweight individuals. A total of 4 studies were conducted among Canadian adolescents (n = 1,452) and university students (n = 424). Results suggested that the AFAS possessed a unidimensional factor structure and satisfactory reliability for both men and women. As predicted, men obtained higher scores than women on the AFAS, and antifat attitudes were positively associated with authoritarianism, homonegativity, and political conservatism. Participants who were overweight had lower scores on the AFAS than participants who were thin or average weight. Responses on the AFAS did not appear to be contaminated by social desirability bias. PMID:10457760
1999-08-01
Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer
International Nuclear Information System (INIS)
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to image biological tissue ...
2008-05-07
British Library Electronic Table of Contents (United Kingdom)
Unilateral diaphragmatic paralysis was diagnosed in 2 preterm neonates born at 29 and 25 weeks of gestation, respectively. In both instances, the pathophysiology was phrenic nerve injury after extravasation of parenteral nutrition fluid. Misplacement and infection were predisposing factors. Diaphragmatic movement analysis by time-motion-mode ultrasonography was helpful in achieving a diagnosis. The first neonate required a diaphragmatic placation, whereas the other infant was managed nonoperatively. These cases confirm a rare etiology of diaphragmatic paralysis and possible spontaneous recovery. In neonates with very low birth weight, general anesthesia and thoracic surgery may be associated with a high morbidity, suggesting that nonoperative medical treatment, when possible, is preferable...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The analysis is submitted in support of the effluent limitations guidelines and standards for the Coastal Oil and Gas Industry. The report analyzes the cost-effectiveness of 10 regulatory options organized by three wastestreams. The document compares the total annualized cost incurred for each of the regulatory options within each wastestream to the corresponding effectiveness of that option in reducing the discharge of pollutants. Section Two discusses the cost-effectiveness methodology used and identifies the pollutants included in the analysis, presenting their toxic weighting factors and removal efficiencies. Section Three presents the results of the analysis. In Section Four, the cost-effectiveness values are compared to cost-effectiveness values for other promulgated rules. Appendix A presents data on pollutants, pollutant removals, annualized costs, and other, more detailed information.
1995-01-01
The cost-effectiveness (CE) analysis presents an evaluation of the technical efficiency of pollutant control options for the proposed effluent limitations guidelines. The proposed BAT and PSES apply to six subcategories: Dissolving Kraft; Dissolving Sulfite; Bleached Papergrade Kraft; Papergrade Sulfite; Unbleached Kraft; and Semichemical. The document compares the total annualized cost incurred for each of the regulatory options within each subcategory to the corresponding effectiveness of that option in reducing the discharge of pollutants. Section Two discusses the cost-effectiveness methodology and identifies the pollutants included in the analysis and their toxic weighting factors. Section Three describes the options evaluated for each subcategory. Section Four presents the results of the CE analysis. Section Five presents a separate analysis of AOX (adsorbable organic halides).
1993-11-01
British Library Electronic Table of Contents (United Kingdom)
Abstract The fit of patient coping style and psychotherapy focus has been suggested as improving treatment outcome. This article reviews the definitions, measures, and previous research surrounding this hypothesis. An original meta-analysis of 12 carefully selected studies (N = 1,291 patients) resulted in a weighted, mean effect size (d) of .55 in favor of a fit between externalizing patients and symptom-focused treatment or, alternatively, internalizing patients and insight-focused treatment. This medium-size effect indicates that nondiagnostic patient factors, like coping style, are important considerations in the selection of effective therapies. Clinical examples and clinical recommendations are provided. 2010 Wiley Periodicals, Inc. J Clin Psychol: In Session 67:176-183, 2011.
2011-01-01
Coordinated control of multiple manipulator systems
Energy Technology Data Exchange (ETDEWEB)
A scheme for controlling multimanipulator systems is presented. The control objective is to coordinate the manipulators to perform parts-matching tasks such as screwing a nut onto a bolt. The task of moving a rigid object can be treated as a special case. Two secondary control objectives internal force control and load distribution can be accomplished within the structure of the control law. The internal force control mechanism keeps the internal forces on the object being manipulated at a desirable level. The load distribution mechanism distributes control effort to each manipulator according to a weighting factor. It is also shown that the control algorithm has a modular structure which facilitates its implementation on a multiprocessor computer. The scheme was tested on a planar scara type dual-manipulator system. A series of experimental results is included to demonstrate the system performance under various conditions.
1993-08-01
Energy Technology Data Exchange (ETDEWEB)
The increasing use of quantum-chemical methods in catalysis has underscored the importance of developing and improving semiempirical approximations oriented toward calculations of the total energy and geometry, offering a means for examining intermolecular interactions. In this article a general approach is proposed, using weighting factors for certain regions of distances, i.e., introducing different parametrization into the various regions. A scheme designated MINDO/3-HB is presented as an extension of the MINDO/3 scheme to the region of hydrogen bonds and ..pi..-complexes of olefins with Broensted acid centers (BACs). Examples of cluster calculations are given for the adsorption of ammonia, pyridine, ethylene, and ethanol on the BACs of zeolites. In the example of the process of zeolite synthesis, the possibilities of the cluster approach are discussed for calculations related to the formation of catalysts.
1987-07-01
Application of drive systems for mine haulage systems
Energy Technology Data Exchange (ETDEWEB)
There are many different types of open pit mining operations around the world, and the challenge for any drive system manufacturer is to produce a system(s) that will work satisfactorily in these mines. Several factors must be considered such as vehicle speed requirements, available engine horsepower, mine rolling resistance, grades, grade lengths, payload, and tire sizes. How well a particular drive system performs depends on the size, weight, and available tractive/retarding effort. In addition to performance, the system must also have an operating cost that will be acceptable over the life of the equipment. Today the choice of drive systems is not only between mechanical and electrical drives, but also within these categories are the different manufacturers. Regardless of how the power is provided to the rear wheels, the job must be accomplished reliably and at an acceptable cost. This paper covers the characteristics of an electric drive ...
1989-01-01
We hypothesize that the mushroom-derived active compound may be a potential strategy for increasing survival in response to influenza virus (H1N1) infection through the stimulation of host innate immune response. The validity of the hypothesis can be tested by immune response to influenza infection as seen through survival percentage, virus clearance, weight loss, natural killer cell cytotoxicity, Tumor Necrosis Factor-? (TNF-?) and Interferon-gamma (IFN-?) levels, lytic efficiency in the spleens of mice and inducible nitric oxide synthase mRNA expressions in RAW 264.7 murine macrophage cells. The hypothesis may improve people's quality of life, reduce the medical cost of our healthcare system and eliminate people's fears of influenza outbreak. PMID:21660092
2011-03-20
Effect of humidity in a mixture on combustion (Part 1). Effect on laminar burning velocity
Energy Technology Data Exchange (ETDEWEB)
In order to investigate the effect of humidity on laminar burning velocity(S), the effect of humidity on the combustion reaction and radiation intensity was studied, taking account of dilution gases such as CO/sub 2/ and Ar which has the approximately identical characteristics to exhaust gas circulation(EGR) gas used to prevent NOx discharge from engines. According to the heat reaction theory, mean specific heat(C) of mixture, mean molecular weight(M) and adiabatic flame temperature(T) etc. were said to affect S but from experimental results, the effect of M and C could be ignored, compared with the effect of T. The relationship between S and H/sub 2/O, Ar of CO/sub 2/% in mixture of diluted gases was clarified. The effect of H/sub 2/O on S was mainly caused by changes of T. The effect of radical C/sub 2/, CH and OH on radiation intensity was similar to that of H/sub 2/O and Ar and the effect of H/sub 2/O on combustion was ...
1987-08-25
Local Radiation MHD Instabilities in Magnetically Stratified Media
We study local radiation magnetohydrodynamic instabilities in static, optically thick, vertically stratified media with constant flux mean opacity. We include the effects of vertical gradients in a horizontal background magnetic field. Assuming rapid radiative diffusion, we use the zero gas pressure limit as an entry point for investigating the coupling between the photon bubble instability and the Parker instability. Apart from factors that depend on wavenumber orientation, the Parker instability exists for wavelengths longer than a characteristic wavelength lambda_{tran}, while photon bubbles exist for wavelengths shorter than lambda_{tran}. The growth rate in the Parker regime is independent of the orientation of the horizontal component of the wavenumber when radiative diffusion is rapid, but the range of Parker-like wavenumbers is extended if there exists strong horizontal shear between field lines ...
2011-01-01
Intensification of harmonic spontaneous radiation with a novel undulator
International Nuclear Information System (INIS)
We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessivecurrent in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeV electrons taking K1 is greatly enhanced for the approximate square-wave magnetic profile: the ratio of the power emitted at f=5 by the square-wave undulator to that of the sine-wave undulator ...
1999-07-01
International Nuclear Information System (INIS)
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The balance of the relative fluence weight in a each bin and its average energy, which ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
ABSTRACT-Here we identify release of annexin A2 into the culture medium in response to low dose X-ray radiation exposure and establish functional linkages to an established paracrine factor-mediated anchorage-independent growth response. Using a standard bicameral coculture model, we observe that annexin A2 levels associated with non-irradiated neighboring cells seeded in the lower chamber (annexin A2 silenced [shRNA] JB6 cells) are increased upon coculture with irradiated (10-50 cGy) JB6 cells seeded in the upper chamber, relative to coculture with sham exposed JB6 cells seeded in the upper chamber, suggesting that annexin A2 released into the medium is capable of communicating in a paracrine fashion. Using a previously established coculture model, we observed that the paracrine factor-mediated anchorage-independent growth response to low dose X-ray radiation is markedly reduced when irradiated annexin ...
2009-07-13
The aggregation of climate change damages. A welfare theoretic approach
International Nuclear Information System (INIS)
The economic value of environmental goods is commonly determined using the concepts of willingness to pay (WTP) or willingness to accept (WTA). However, the WTP/WTA observed in different countries (or between individuals) will differ according to socio-economic characteristics, in particular income. This notion of differentiated values for otherwise identical goods (say, a given reduction in mortality risk) has been criticized as unethical, most recently in the context of the 'social cost' chapter of the IPCC Second Assessment Report. These critics argue that, being a function of income, WTP/WTA estimates reflect the unfairness in the current income distribution, and for equity reasons uniform per-unit values should therefore be applied across individuals and countries. This paper analyses the role of equity in the aggregation of climate change damage estimates, using basic tools of welfare economics. It shows one way of how WTP/WTA estimates can be corrected in aggregation if the ...
1997-01-01
Cryogenic coolers are often used in modern spacecraft in conjunction with sensitive electronics and sensors of military, commercial and scientific instrumentation. The typical space requirements are: power efficiency, low vibration export, proven reliability, ability to survive launch vibration/shock and long-term exposure to space radiation. A long-standing paradigm of exclusively using "space heritage" equipment has become the standard practice for delivering high reliability components. Unfortunately, this conservative "space heritage" practice can result in using outdated, oversized, overweight and overpriced cryogenic coolers and is becoming increasingly unacceptable for space agencies now operating within tough monetary and time constraints. The recent trend in developing mini and micro satellites for relatively inexpensive missions has prompted attempts to adapt leading-edge tactical cryogenic coolers for suitability in the space environment. The primary ...
2011-05-01
Somatogenic hormones play an important role in regulation of receptors for prolactin (PRL) and estrogen. Plerocercoids of the tapeworm, S. mansonoides produce a factor which mimics some, but not all of the actions reported for GH. Intact female rats were subjected to a constant infusion of plerocercoid growth factor (PGF) via a subcutaneous infection for two weeks to determine if PGF influences receptors for PRL, GH or estradiol. The rate of weight gain in the PGF-treated rats was accelerated in spite of a marked reduction in serum GH. Partially-purified PGF specifically displaced [125I]hGH from rat liver receptors but microsomes prepared from rats treated with PGF specifically bound significantly less [125I]hGH than microsomes from control rats. The reduction in [125I]hGH binding was not due to occupancy or to a change in affinity but to a suppression in receptor concentration. Scatchard analysis of [3H]estradiol binding ...
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Conditioned medium from Sertoli cells, prepared from testes of 20-day-old rats, contains component(s) that inhibit the incorporation of (3H)-thymidine into DNA of peritubular myoid cells (PMC) and inhibit the proliferation of PMC. These components are trypsin-resistant, heat-stable compounds having a molecular weight less than 30,000. The active inhibitory components in Sertoli cell conditioned medium are inactivated by treatment with heparinase, but not by treatment with hyaluronidase or chondroitin sulfate lyases. Addition of heparin or heparan sulfate results in inhibition of DNA synthesis by PMC in a dose-dependent manner, whereas other glycosaminoglycans (GAGs) examined (hyaluronic acid, keratan sulfate, and chondroitin sulfate) have no detectable effects. Heparin and heparan sulfate are unique among GAGs tested in inhibiting the characteristic multilayer growth pattern of PMC following the attainment of confluence in serum-rich medium. On the basis of these ...
1991-06-01
Viscosity changes in hyaluronic acid: Irradiation and rheological studies
Energy Technology Data Exchange (ETDEWEB)
Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher concentrations, possibly due to the contribution to viscosity from ...
2010-04-15
Energy Technology Data Exchange (ETDEWEB)
Ford, Bacon, Davis Utah Inc. has reevaluated the Spook site in order to revise the December 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings 48 mi northeast of Casper, in Converse County, Wyoming. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 187,000 tons of tailings at the Spook site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.
1981-10-01
Radiation damage in A-15 materials: EXAFS studies
International Nuclear Information System (INIS)
EXAFS measurements are useful in determining the local atomic environment of a particular element in a solid. Since there has been some controversy about the nature of the defects produced in A-15 materials by radiation damage, such studies were carried out on some A-15 compounds, V_3Ga which was damaged by neutrons, as well as Nb_3Ge damaged by 2.5 MeV a particles. In the V_3Ga sample, site exchange disorder seems to be the most important result of the neutron damage with less than 20% of the vanadium atoms on wrong sites. However, in the Nb_3Ge samples in addition to site exchange disorder, an unusual splitting of the first near-neighbor distance between the Ge and Nb is found. This splitting, approximately 0.2 A, may explain the large Debye Waller factors observed by Burbank et al.
Estimating extreme values of thermal gradients in concrete structures
British Library Electronic Table of Contents (United Kingdom)
Temperature variations due to climate changes are a major cause of movements in a concrete structure, both in the longitudinal and transversal directions and between different parts of the structure. If these movements are restrained, stresses will be induced which may contribute to cracking. The movements are caused by complex interactions of several factors such as solar radiation, air temperature, long-wave heat radiation and wind speed. To predict the varying thermal conditions in a concrete structure a finite element model has been used. A validation of the model has been performed using field measurements in a concrete slab together with climate data from the Swedish Meteorological and Hydrological Institute to be able to use the model for simulations over long time periods and for s...
2011-01-01
Engineering assessment of inactive uranium mill tailings, Tuba City site, Tuba City, Arizona
Energy Technology Data Exchange (ETDEWEB)
Ford, Bacon and Davis Utah Inc. has reevaluated the Tuba City site in order to revise the March 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings at Tuba City, Arizona. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 0.8 million tons of tailings at the Tuba City site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.
1981-09-01
Electron accelerators, present and future applications
International Nuclear Information System (INIS)
The development and occurrence of new electron accelerators and applications are according to the human society development law, as a whole. The period of economic standstill is generating an intense creative activity in the domain of science and engineering which also resulting in great achievements in the field of electron accelerators. This paper presents the basic principle of the electron beam applications and the accelerators required characteristics for their present and potential applications in the domains: radiation sources, diagnostics, radiation processing, energetics, environment, defense and basic sciences. All these are correlated to the new generation of accelerators which, for the acceleration process, may employ electromagnetic fields generated by standard sources, atomic lasers, free electron lasers, Cerenkov effect, Smith - Purcell effect, electron beams, plasma, excited atoms into a crystal or other sources. Some more ...
Energy Technology Data Exchange (ETDEWEB)
The existing theoretical and experimental basis for predicting the levels of resonant static error field at different components m,n that stop plasma rotation and produce a locked mode is reviewed. For ITER ohmic discharges, the slow rotation of the very large plasma is predicted to incur a locked mode (and subsequent disastrous large magnetic islands) at a simultaneous weighted error field ({Sigma}{sub 1}{sup 3}w{sub m1}B{sup 2}{sub rm1}){sup {1/2}}/B{sub T} {ge} 1.9 x 10{sup -5}. Here the weights w{sub m1} are empirically determined from measurements on DIII-D to be w{sub 11} = 0. 2, w{sub 21} = 1.0, and w{sub 31} = 0. 8 and point out the relative importance of different error field components. This could be greatly obviated by application of counter injected neutral beams (which adds fluid flow to the natural ohmic electron drift). The addition of 5 MW of 1 MeV beams at 45{degrees} injection would increase the error field limit by a ...
1997-02-01
Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada
Energy Technology Data Exchange (ETDEWEB)
Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and red marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and Snowdrift caribou and wolves, calculated from tissue activities, ranged from 7-20 mSv y{sup {minus}1} using human weighting factors ...
1994-06-01
Transfer Factors of {sup 85}Sr and {sup 137}Cs for Rice in Three Paddy Soils from the Wolsung Area
Energy Technology Data Exchange (ETDEWEB)
Several nuclear power plants are operating in Wolsung area, a south-east coastland of Korea. In addition, a medium-level radioactive waste repository is under construction there. If radionuclides are released from these facilities, food crops could be radioactively contaminated, leading to human exposure to internal radiations via food consumption. There are a number of rice fields around the Wolsung nuclear sites. However, almost nothing has yet been reported on the transfer of radionuclides to rice plants from Wolsung soils. In this study, {sup 85}Sr and {sup 137}Cs transfer factors (TFs) were measured for the rice in three paddy soils collected around the Wolsung nuclear sites.
2009-10-15
Transfer Factors of 85Sr and 137Cs for Rice in Three Paddy Soils from the Wolsung Area
International Nuclear Information System (INIS)
Several nuclear power plants are operating in Wolsung area, a south-east coastland of Korea. In addition, a medium-level radioactive waste repository is under construction there. If radionuclides are released from these facilities, food crops could be radioactively contaminated, leading to human exposure to internal radiations via food consumption. There are a number of rice fields around the Wolsung nuclear sites. However, almost nothing has yet been reported on the transfer of radionuclides to rice plants from Wolsung soils. In this study, 85Sr and 137Cs transfer factors (TFs) were measured for the rice in three paddy soils collected around the Wolsung nuclear sites
2009-10-01
British Library Electronic Table of Contents (United Kingdom)
Possible factors regulating phytoplankton variability in the Arabian (Persian) Gulf were analyzed on the basis of satellite observations and meteorological data (1997-2009), including remotely-sensed chlorophyll a concentration (CHL), sea surface temperature, wind, solar radiation, precipitation, and aerosols. Shallow waters of northwestern Gulf influenced by Shatt Al-Arab River discharge were more productive than open Gulf waters, although seasonal CHL patterns in this and other shallow regions looked unrealistic likely because the CHL signal was obscured by bottom reflection. Therefore our further analyses focused on the open Gulf waters, which show a subtropical seasonal CHL cycle with maximum in winter and minimum in spring-summer. This cycle, however, was decoupled from the seasonal e...
2010-01-01
Modeling of a self-excited pulse combustor and stability analysis
British Library Electronic Table of Contents (United Kingdom)
The major bottleneck for popularization and utilization of the conventional mechanical valve pulse combustors is the self-priming mode of gas supply. An aerodynamic valve (as against mechanical valve) self-excited pulse combustor of the Helmholtz-type with continuous supply of gas and air was designed and a mathematical model was established in this paper. The theoretical model employed well-stirred reactor model and a single step Arrhenius chemistry, and took those factors which might affect the combustion stability into account. The factors include the variation of the mass rate of the reactants affected by the pressure in the combustion chamber, the convective and radiation heat loss in the combustion chamber, and the heat transfer and wall friction in the tailpipe. The effect of wall t...
2011-01-01
Geometric configuration factors for polygonal zones using Nusselt's unit sphere
Energy Technology Data Exchange (ETDEWEB)
The Energy Laboratory of the University of Houston has developed a computer simulation program called CREAM (Cavity Radiation Exchange Analysis Model) for application to the solar central receiver system. CREAM contains a geometric configuration factor generator based on Nusselt's method. A formulation of Nusselt's method provides the basis for a FORTRAN subroutine NUSSELT. Numerical results from NUSSELT are compared to analytic values and values from Sparrow's method. Sparrow's method is based on a double contour integral and its reduction to a single integral which is a approximated by Gaussian methods. Nusselt's method is adequate for the intended engineering applications, but Sparrow's method is an order of magnitude more efficient in many situations.
1983-05-01
Cellular Sources of Transforming Growth Factor-? Isoforms in Early and Chronic Radiation Enteropathy
The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural ...
1998-11-01
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Radiation technology of wood-plastic composite materials
International Nuclear Information System (INIS)
... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.
1981-10-02
Radiation chloration sulfochloration and sulfooxidation of organic compounds
International Nuclear Information System (INIS)
... halogenation ionizing radiations kinetics radiations reaction kinetics
International Nuclear Information System (INIS)
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a result of the low doses of radiation but also by preventing some of the endogenous inversions that would have ...
2006-04-01
Synchrotron Self-Compton Analysis of TeV X-ray Selected BL Lacertae Objects
We introduce a methodology for analysis of multiwavelength data from X-ray selected BL Lac (XBL) objects detected in the TeV regime. By assuming that the radio--through--X-ray flux from XBLs is nonthermal synchrotron radiation emitted by isotropically-distributed electrons in the randomly oriented magnetic field of a relativistic blazar jet, we obtain the electron spectrum. This spectrum is then used to deduce the synchrotron self-Compton (SSC) spectrum as a function of the Doppler factor, magnetic field, and variability timescale. The variability timescale is used to infer the comoving blob radius from light travel-time arguments, leaving only two parameters. With this approach, we accurately simulate the synchrotron and SSC spectrum of flaring XBLs in the Thomson through Klein-Nishina regimes. Photoabsorption by interactions with internal jet radiation and the intergalactic background light (IBL) is included. Doppler ...
2008-01-01
Production of rare earth enriched isotopes and americium 242 using metallphthalocyanines
International Nuclear Information System (INIS)
A technique of producing radioactive isotopes of rare earth elements (r.e.e.) and carrier free "2"4"2Am is suggested. The technique makes use of ''sandwich'' phthalocya=- nine complexes of r.e.e. and americium placed on sorbent. This is a new type of r.e.e. compounds and actinides (C_3_2H_1_6N_8)_2M (M is a metal ion) which are thermally, radiationally and chemically stable, dissolve well in some organic solvents and do not dissolve in water. Radiation and chemically stable activated carbon is used as a sorbent carrier. After irradiation the target is treated by a weakly acid solution or complex-former solution. Radioactive atoms formed due to (n, #gamma#)-reaction and desoleting the complex because of recoil transfer into the solution. When irradiating in the flux of 10"1"3 neutr./cm"2 x s for 1 hour it is possible to produce radioactive isotopes with the yield from 20 to 90%, for example "1"6"0Tb, "1"6"6Ho with enrichment ...
Microclimatic conditions at the external surface of building envelopes
Energy Technology Data Exchange (ETDEWEB)
The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood controlled region, to ...
1999-12-05
Estimation of cancer risks from radiotherapy of benign diseases
Energy Technology Data Exchange (ETDEWEB)
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...
2006-08-15
Estimation of cancer risks from radiotherapy of benign diseases
International Nuclear Information System (INIS)
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...
2006-08-01
International Nuclear Information System (INIS)
This paper reports regulation of hypoxia inducible factor-1 ? (HIF-1 ?)in hepatoma cells by irradiation. Cobalt chloride (CoCl2), a chemical mimic agent for hypoxia research, was utilized to induce the stable expression of HIF-1 ? in HepG2 cells. The HepG2 cells were irradiated to different doses to observe the changes of HIF-1 ?. The level of intracellular reactive oxygen species (ROS) was assayed by fluorescent microscope and flow cytometry (FCM). The results showed that there were obvious changes in expression of HIF-1 ? after HepG2 cells exposed to radiation, and the changes were positively related with the irradiation dose from 1 Gy to 5 Gy. Moreover, contents of incellular ROS were negatively correlated with above levels of HIF-1 ? from 1 Gy to 3 Gy. The results indicate that irradiation may enhance hypoxic cells HIF-1 ?, and the reduction of intracellular ROS can contribute to the regulation of ionizing radiation on ...
2007-10-01
For understanding on basic radiation mechanism of the high-gain FEL based on SASE, the author presents electron-crystal interpretation of FEL radiation. In the electron-crystal, electrons are localized at regularly spaced multi-layers, which represents micro-bunching, whose spacing is equal to the radiation wavelength, and the multi-layers are perpendicular to beam axis, thus, diffracted wave creates Bragg's spots in forward and backward directions. Due to the Doppler's effect, frequency of the back-scattered wave is up-converted, generates forwardly focused X-ray. The Bragg's effect contributes focusing the X-ray beam into a spot, thus peak power becomes extremely higher by factor of typically 107. This is the FEL radiation. As well known, the total numbers of scattered photons in Bragg's spots is equal to the total elastic scattering photons ...
2007-01-19
Assessing radiologic risk for population due to human activities
International Nuclear Information System (INIS)
The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...
2002-09-06
Overview of bunch length measurements.
Energy Technology Data Exchange (ETDEWEB)
An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.
1999-02-19
Estimation of armature condition in concrete with gamma-absorption method
International Nuclear Information System (INIS)
Bases of the algorithm for assessing the reinforcement status in reinforced concrete products by gamma-absorption method are presented. Analytical equations are obtained for estimation of error of the parameter characterizing the degree of reinforcement destruction. It is recommended to use high-energy Bremsstrahlung sources-betatrons of 4-10 MeV maximum energy for testing products of 500-600 mm thick. Linear radiation attenuation factor (LAF) of concrete in estimated equation is replaced by effective LAF of concrete, and LAF of reinforcement and corrosion materials - by differential LAF. Corresponding LAF of nonevident form in the algorithm is assessed by the results of processing of direct-shadow radiographs of defectometers
Efficient Cartesian-grid-based modeling of rotationally symmetric bodies
DEFF Research Database (Denmark)
Axially symmetric waveguides, resonators, and scatterers of arbitrary cross section and anisotropy in the cross section can be modeled rigorously with use of 2-D Cartesian-grid based codes by means of mere redefinition of material permittivity and permeability profiles. The method is illustrated by the frequencydomain simulations of resonant modes in a circular-cylinder cavity with perfectly conducting walls, a shielded uniaxial anisotropic dielectric cylinder, and an open dielectric sphere for which, after proper implementation of the perfectly matched layer boundary conditions, the radiation quality factor is also determined.
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
1993-09-01
Key impact parameters for application of alternative source term to Kori unit 1
International Nuclear Information System (INIS)
The object of this paper is to identify the key elements that impact a radiation dose at EAB (Exclusion Area Boundary). This study is based on the AST (Alternative Source Terms) as defined in Regulatory Guide 1.183. The LOCA (Loss of Coolant Accident) and the LRA (Locked Rotor Accident) are selected as limiting cases. A sensitivity analysis of accidental behavior with respect to various parameters during LOCA and LRA at Kori Unit 1 is also undertaken for the following objectives: to determine the limiting parameters, to find the impact trend of the radiation dose, and to find the safety margin between AST and TID (Technical Information Document) methodologies. This work confirms that key parameters are particulate removal rate, decontamination factor, iodine chemical form, gap fraction, partitioning factor, and the impact of isotopes group. Comparing TID with AST, the radiation dose ...
2010-08-01
We study the structure of the medium surrounding sites of high-mass star formation to determine the interrelation between the HII regions and the environment from which they were formed. The density distribution of the surroundings is key in determining how the radiation of the newly formed stars interacts with the surrounds in a way that allows it to be used as a star formation tracer. We present new Herschel/SPIRE 250, 350 and 500 mum data of LHA 120-N44 and LHA 120-N63 in the LMC. We construct average spectral energy distributions (SEDs) for annuli centered on the IR bright part of the star formation sites. The annuli cover ~10-~100 pc. We use a phenomenological dust model to fit these SEDs to derive the dust column densities, characterise the incident radiation field and the abundance of polycyclic aromatic hydrocarbon molecules. We see a factor 5 decrease in the radiation field energy density as a ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in ...
2009-10-15
Development of radiological emergency preparedness and biological dosimetry technology
Energy Technology Data Exchange (ETDEWEB)
Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of ...
1999-04-01
UK PubMed Central (United Kingdom)
ObjectiveMaintaining weight loss is a major challenge in obesity treatment. Individuals often indicate that waning motivation prompts cessation of effective weight...Full Text Available
2011-02-01
The Results of Curative Concurrent Chemoradiotherapy for Anal Carcinoma
Energy Technology Data Exchange (ETDEWEB)
To evaluate the predictive factors for treatment response and prognostic factors affecting survival outcomes after concurrent chemoradiotherapy (CCRT) for patients with anal squamous cell carcinoma. Medical records of forty two patients with histologically confirmed analsquamous cell carcinoma, who had complete CCRT between 1993 and 2008, were reviewed retrospectively. Median age was 61.5 years (39-89 years), and median radiotherapy (RT) dose was 50.4 Gy (30.0-64.0 Gy). A total of 36 patients had equal to or less than T2 stage (85.7%). Fourteen patients (33.3%) showed regional nodal metastasis, 36 patients (85.7%) were treated with 5-fluorouracil (5-FU) plus mitomycin, and the remaining patients were treated by 5-FU plus cisplatinum. The median follow--up time was 62 months (2-202 months).The 5-year overall survival, locoregional relapse-free survival, disease-free survival, and colostomy-free survival rates were 86.0%, 71.7%, 71.7%, 78.2%, ...
2010-11-15
The tunneling universe in scalar-tensor theory with matter
Energy Technology Data Exchange (ETDEWEB)
In this paper, the wavefunction of the universe with a tunneling boundary condition is considered in the context of the Brans-Dicke-type scalar-tensor theory with matter. The matter may be interpreted as a D-particle (or D0-brane) in string theory when the Brans-Dicke parameter {omega} is -1. We study two simple examples. The first example, the {gamma}=0 (matter) case, has a scale factor duality even if the low energy string action is coupled to matter. The universe undergoes quantum transition from super-inflationary (pre-big-bang) to deflationary (post-big-bang) phase. We calculate the transition rate by solving the Wheeler-DeWitt equation and find that it is non-vanishing. The two phases are disconnected classically. The second example is the {gamma}=1/3(radiation) case. With the help of earlier work this matter can be identified with a D0-brane in string theory. In this case, due to the absence of the scale factor ...
2007-10-21
RESOLVING DOPPLER-FACTOR CRISIS IN ACTIVE GALACTIC NUCLEI: NON-STEADY MAGNETIZED OUTFLOWS
International Nuclear Information System (INIS)
Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the gamma-ray emission, delayed with ...
2010-10-10
ISR Hadron Production in e+e- Annihilations and Meson-Photon Transition Form Factors
We present several recent results from the BaBar collaboration in the areas of initial state radiation physics and transition form factors. An updated study of the processes e+e- -> K+K-pi+pi- and e+e- -> K+K-pi0pi0 provides an improved understanding of the Y(2175) meson. A very precise study of the process e+e- -> pi+pi- improves the precision on the calculated anomalous magnetic moment of the muon and provides by far the best information on excited rho states. Our previous measurements of the timelike transition form factors (TFF) of the eta and eta' mesons at Q^2=112 GeV^2, combined with new measurements of the their spacelike TFFs and those of the pi0 and eta_c mesons, provide powerful tests of QCD and models of the distribution amplitudes of quarks inside these mesons. The eta_c TFF shows the expected behavior over the Q^2 range 1-50 GeV^2, and we are sensitive to next-to-leading-order QCD corrections. The eta ...
2011-01-01
Hypothalmic hypopituitarism following cranial irradiation for nasopharyngeal carcinoma
Energy Technology Data Exchange (ETDEWEB)
Eight patients, one male and seven females, with no pre-existing hypothalamic-pituitary disease, who developed symptoms of hypopituitarism following cranial irradiation for nasopharyngeal carcinoma were studied 5 years or more after radiotherapy. All were GH deficient. Four of the patients with no GH response during insulin tolerance tests (ITT) showed increased GH in response to synthetic human growth hormone releasing factor (GRF-44). Four patients had impaired cortisol responses to ITT, and gradual but diminished cortisol responses to ovine corticotrophin releasing factor (CRF-41). There was no significant difference between mean peak increments in response to ITT and those in response to CRF-41. TSH responses to TRH were delayed in five and absent in two patients; four of these had low free T4 index. Prolactin was raised in all seven women and increased further in response to TRH. Two patients had impaired gonadotrophin responses to LHRH. ...
1986-06-01
Home radon levels and seasonal correction factors for the Isle of Man
Energy Technology Data Exchange (ETDEWEB)
Ionizing radiation dose levels due to home radon can rise to levels that would be illegal for workers in the nuclear industry. It is well known that radon levels within homes and from home to home, and also from month to month, vary considerably. To define an Isle of Man radon seasonal correction factor, readings were taken in eight homes over a 12 month period. An average island indoor exposure of 48 Bq m{sup -3} (range 4-518 Bq m{sup -3}) was determined from 285 homes selected from a cohort of 1300 families participating in the European Longitudinal Study of Pregnancy and Childhood (ELSPAC) in the Isle of Man. This compares with a UK home average of 20 Bq m{sup -3} and a European Union average (excluding UK) of 68 Bq m{sup -3}. Ten homes of those measured were found to have radon levels above the National Radiological Protection Board 200 Bq m{sup -3} action level. There are 29 377 homes on the Isle of Man, suggesting that there could be some ...
2000-08-01
Energy Technology Data Exchange (ETDEWEB)
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...
2000-03-01
International Nuclear Information System (INIS)
Studies have linked cell phone radiation to health problems such as headaches, high blood pressure, cancer and more. There is a latency period for most diseases and it may take years and more studies before the required weight of evidence is established. But the effects are cumulative and precautions should be taken now before it is too late. The aim of the present study was to investigate if supplementation with antioxidants would protect heart and liver tissues from harmful radiation emitted by cell phone. Thirty two male albino rats were randomly divided into four equal groups: I- Control, II- Antioxidants treated group, III- 950 MHz EMR, IV- 950 MHz EMR + antioxidants. A 950 MHz EMR radiation (217-Hz pulse rate, 2-W maximum peak power, SAR Specific Absorption Rate"1.6 W/Kg) was applied to groups III and IV 60 min/day, for 30 days using an experimental exposure device. Antioxidants supplement ...
Electron-beam induced RAFT-graft polymerization of poly(acrylic acid) onto PVDF
Energy Technology Data Exchange (ETDEWEB)
This paper explores for the first time the post-radiation-induced-graft polymerization on solid substrate using reversible addition-fragmentation transfer (RAFT) mechanism. Radiation-induced graft polymerization onto polymers is a potentially interesting technique to create easily new materials from highly resistant polymers, e.g. surface graft polymerization of acrylic acid (AA) onto poly(vinylidene difluoride) (PVDF) improves its surface properties without losing its excellent mechanical properties. As a consequence of the radical nature of the polymerization processes it is difficult to control molecular weight of grafted chains, and therefore design and standardize the properties of the final product. RAFT polymerization is a suitable method to obtain monodisperse polymers. The ability of the RAFT agents to control the polymer chain length could be an interesting approach to improve the grafted polymers obtained by ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The clinical results of electron beam therapy using intraoral cone in 8 cases of primary and recurrence carcinoma of tongue (T1 and smaller T2) were reported. The primary and recurrence cases were 5 and 3, respectively. In the 5 cases, a total dose of 10-30 Gy external radiation therapy were combined prior to electron beam therapy. The total dose of electron beam therapy varied from 40 to 60 Gy. In all cases, tumor showed good response and disappeared clinically. Radiation stomatitis, pain of the tongue with masticatory disturbance due to tenderness were complicated in all cases. These complications gradually disappeared 2 to 6 months after treatment. However, loss of body weight and bone exposure were not recognized in any case. Intraoral-cone electron beam therapy is thought to be available and has less complications comparing interstitial irradiation therapy from the review of literature. Within 6 months after ...
1989-06-01
Energy Technology Data Exchange (ETDEWEB)
Land surface parameterization schemes such as the Simple Biosphere Model (SiB2) have found considerable use in climate simulation models, where they provide lower boundary conditions in the form of surface sensible and latent heat fluxes. A methodology is described to apply models of this type at high resolution, using data from the Department of Energy{close_quote}s Cloud and Radiation Testbed in Oklahoma and Kansas, to determine the spatial variations of heat fluxes over the domain and to determine area-weighted flux averages for use in single-column model studies. Data from a dense array of meteorological instruments are interpolated to provide the wind, temperature, vapor pressure, radiation, and precipitation values needed by SiB2. The state of the vegetation is characterized through the use of the normalized difference vegetation index determined from satellites. The performance of the SiB2 model is evaluated by ...
1998-03-01
Weighted shifts on directed trees
A new class of (not necessarily bounded) operators related to (mainly infinite) directed trees is introduced and investigated. Operators in question are to be considered as a generalization of classical weighted shifts, on the one hand, and of weighted adjacency operators, on the other; they are called weighted shifts on directed trees. The basic properties of such operators, including closedness, adjoints, polar decomposition and moduli are studied. Circularity and the Fredholmness of weighted shifts on directed trees are discussed. The relationships between domains of a weighted shift on a directed tree and its adjoint are described. Hyponormality, cohyponormality, subnormality and complete hyperexpansivity of such operators are entirely characterized in terms of their weights. Related questions that arose during the study of the topic are solved as well. ...
2009-01-01
The Combined Influence of Molecular Weight and Temperature on the ...
[12] Kusy, R. P. and Turner, D. T.: Influence of molecular-weight ofpoly(methyl methacrylate)on fracture morphology in notched tension, Polymer. ...
Radiant emittance of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The product of this ...
1994-12-31
On-site radiation exposure in severe reactor accidents: Scoping study
Energy Technology Data Exchange (ETDEWEB)
The results of a scoping study of onsite radiation exposures which could take place in each of three types of postulated reactor accidents are presented. The accident types are (1) a fuel handling accident at a Mark III BWR; an interfacing system LOCA or V sequence at a PWR; and and Anticipated Transient Without Scram (ATWS) at a Mark I BWR. Both external and internal dose pathways are considered. The results of the study indicate the prohibitively high radiation doses could be received in some plant areas if personnel were to remain there. However, times of the order of a few minutes to a few hours, depending on the type of accident, would be available before life-threatening doses would be accumulated assuming that the provided full face respiratory protection equipment were used promptly. Special attention was given radiation doses possibly received by control room personnel for several control room air in-leakage ...
1990-09-01
Long-term results in 144 localized Ewing's sarcoma patients treated with combined therapy
International Nuclear Information System (INIS)
The results of 144 previously untreated cases of primary Ewing's sarcoma of bone are reported with a minimum follow-up of 5 years. This series was treated between 1972 and 1982 at Istituto Ortopedico Rizzoli with a combined therapy. The local control of the disease consisted of amputation (ten cases), resection followed by radiation therapy (35-45 Gy) (48 cases) and radiation therapy alone (40-60 Gy) (86 cases). Adjuvant chemotherapy, rigorously standardized, was performed according two different protocols: the first (85 cases treated in the period 1972-1978) consisted of vincristine (VCR) Adriamycin (doxorubicin) (ADM), and cyclophosphamide (EDX); the second (59 cases treated in the period 1979-1982) of VCR, ADM, EDX and dactinomycin (DACT). At a follow-up of 5 to 16 years (median, 9), 59 patients (41%) are continuously disease-free (CDF), 81 (56%) developed metastatic disease and/or local recurrence, and four (3%) had a second malignancy. ...
International Nuclear Information System (INIS)
Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were subsequently interpolated into finer angular intervals for dose calculation to mimic ...
2008-09-07
International Nuclear Information System (INIS)
Apricot fruits usually harvested relatively mature but hard enough to withstand-post harvest handling through the marketing chain. These fruits have considerably lower edible quality than tree-ripened fruit. Fruit quality can be improved by delaying harvest least until physiological maturation is completed on the tree (Bonghi et al. 1999) Apricots containing 11% soluble solids concentration, or higher are in high demand by consumers, as fruit have developed considerable taste, aroma and handling for long distance markets. (Kader, 1999). These fruit will be highly perishable, so rapid cold storage to the lowest safe temperature and supplementary treatments (Mc Donald et al, 1999) such as irradiation with the recommend doses (Sillano et al, 1994) or pre-storage heat treatments will be necessary to retard ripening (mainly softening) during 1-2 weeks post harvest life necessary for distribution to distant markets (Mc Donald et al 1999). Therefore, one can conclude that spraying Canino ...
2003-03-01
International Nuclear Information System (INIS)
A new leaf-sequencing approach has been developed that is designed to reduce the number of required beam segments for step-and-shoot intensity modulated radiation therapy (IMRT). This approach to leaf sequencing is called continuous-intensity-map-optimization (CIMO). Using a simulated annealing algorithm, CIMO seeks to minimize differences between the optimized and sequenced intensity maps. Two distinguishing features of the CIMO algorithm are (1) CIMO does not require that each optimized intensity map be clustered into discrete levels and (2) CIMO is not rule-based but rather simultaneously optimizes both the aperture shapes and weights. To test the CIMO algorithm, ten IMRT patient cases were selected (four head-and-neck, two pancreas, two prostate, one brain, and one pelvis). For each case, the optimized intensity maps were extracted from the Pinnacle"3 treatment planning system. The CIMO algorithm was applied, and the optimized aperture ...
2006-04-01
Stochastic risk estimation from medical x-ray diagnostic examinations, 3
International Nuclear Information System (INIS)
The genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemia significant dose (LSD) and malignancy significant dose (MSD) from medical diagnostic X-ray examinations in Japan were estimated based on a 1979 nationwide survey of randomly sampled hospitals and clinics. The population risk estimates were carried out using the resultant values of GSD, LSD and MSD. In the risk estimates, the significant factors, namely, the relative child expectancy, the leukemia significant factor and the malignancy significant factor, for patients were assumed to be same as those of general population. The risk factors used were 185 x 10"-"6 rad"-"1 for genetic risk of all generations, 20 x 10"-"6 rad"-"1 for fatal leukemia and 165 x 10"-"6 rad"-"1 for fatal malignant diseases, respectively. The resultant annual population doses per person were 15 mrad (0.15 mGy) for GSD, 107 mrad (1.07 mGy) for ...
International Nuclear Information System (INIS)
Using the linearized augmented-plane-wave (LAPW) -calculated electron and positron charge densities for YBa_2Cu_3O_7, the Brillouin-zone-reduced electron-positron momentum density is computed and the zone-reduced two-dimensional angular correlation of annihilation radiation (2D ACAR) spectrum is produced. The calculations show that the relative weights of the Fermi-surface discontinuities are substantially altered due to the positron preferentially sampling the Cu-O chain region. In addition, the reduced 2D ACAR spectrum contains large k-dependent wave-function effects. The theoretical zone-reduced 2D ACAR spectrum is compared to the several existing experimental spectra. It is concluded that, at present, positron-annihilation experiments do not provide consistent and clear evidence for the existence and shapes of Fermi surfaces in YBa_2Cu_3O_7.
Energy Technology Data Exchange (ETDEWEB)
Considerations were given on typical applications of nylon resin parts to automotive use and their future trends through news topics. GF strengthened nylon resin is used in cylinder head covers substituting aluminum because of advantages in nylon resin of weight reducibility, vibration suppressibility, and noise shielding capability. Radiator tank uses N66GF 30% strengthened nylon in more than 60% of bonnet type passenger cars. Nylon resin is used most in harness connectors installed in locations that require heat resistance. External car parts such as bumpers, fenders, and wheel caps use to some extent nylon resin in the form of strengthened and up-graded polymer alloy. BMW in Germany used in its high-class production cars intake manifolds made of GF strengthened Nylon 66. The majority of engine{prime}s gas intake system parts has been replaced with Nylon blow-formed parts. The resin industry is aiming at developing Nylon resin with aromatic ...
1992-06-18
Measuring head for radionuclide X-ray fluorescence analyzer
International Nuclear Information System (INIS)
The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift of the head during ...
1976-05-21
High-efficiency GaAs solar cells
Energy Technology Data Exchange (ETDEWEB)
An updated review of the state of the art in the development of GaAs solar cells is provided, with emphasis on AlGaAs-GaAs cells suitable for space applications. A set of theoretically derived characteristics is given for this type of solar cell. Comparison of measured performance with theory shows excellent agreement. Data on the effects of radiation damage (high-energy electrons, protons, and neutrons) is also integrated into a form useful for evaluation purposes. Techniques for fabricating (AlGa)As-GaAs solar cells in quantities large enough for practical applications are discussed and are shown to have been demonstrated. The possibility of extending these techniques to the fabrication of very thin low-weight cells for space applications is also considered. Finally, the results obtained to date in the development of GaAs solar cells for applications requiring concentrated sunlight are reviewed, for terrestrial as well as for space ...
1984-05-01
International Nuclear Information System (INIS)
New physical objects, ispalators based on free soap films, exhibit persistent flows of the soap solution in open and closed volumes in air with additions of gases of the C_8F_1_8 type (p = 20 Torr) at temperature drops on the films of the order of tenths and hundredths of kelvin. The flows move continuously at a velocity of 5 - 20 cm s"-"1. It is found that the parts of an inclined ispalator film show anomalous behaviour upon heating: their weight increases and they move downward over the film, whereas the unheated parts of the film move upward. Continuous radial vortex flows accompanied by the formation and washing of the regions of a thin black film are observed on circular films in closed volumes upon their uniform external cooling by evaporating water for 5 - 10 hours. The rapid flows make film ispalators the efficient heat carriers, which operate at small temperature drops (tenths and hundredths of kelvin) and surpass copper in the amount of thermal energy ...
2002-05-31
Energy Technology Data Exchange (ETDEWEB)
As a series of experimental determinations of the thermal diffusivity of molten alkali halides, this paper describes measurements on five molten alkali metal chlorides (LiCl, NaCl, KCl, RbCl, and CsCl) in the temperature range up to 1440 K by the forced Rayleigh scattering method. K[sub 2]Cr[sub 2]O[sub 7] is employed as a dye substance to color the transparent molten salts. In comparison with the present results converted into thermal conductivity, most of the previous experimental data obtained by steady-state methods show larger values, up to about five times, which may be due to the systematic error caused by the presence of convection and radiation. It is found that the thermal conductivity of these series of molten alkali metal chlorides decreases with increasing molecular weight, and their temperature coefficients are weakly negative. 24 refs., 9 figs., 6 tabs.
1992-07-01
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section including guidance on ...
2002-12-01
Stochastic risk estimation from medical x-ray diagnostic examinations, 2
International Nuclear Information System (INIS)
The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and ...
1981-01-01
A scaling Monte Carlo method has been developed to calculate diffuse reflectance from multilayered media with a wide range of optical properties in the ultraviolet-visible wavelength range. This multilayered scaling method employs the photon trajectory information generated from a single baseline Monte Carlo simulation of a homogeneous medium to scale the exit distance and exit weight of photons for a new set of optical properties in the multilayered medium. The scaling method is particularly suited to simulating diffuse reflectance spectra or creating a Monte Carlo database to extract optical properties of layered media, both of which are demonstrated in this paper. Particularly, it was found that the root-mean-square error (RMSE) between scaled diffuse reflectance, for which the anisotropy factor and refractive index in the baseline simulation were, respectively, 0.9 and 1.338, and independently simulated diffuse reflectance was less than or ...
2007-04-01
Optimization of nonhomogeneous facesheets in composite sandwich plates
Minimum weight design is an important criterion in aircraft and spacecraft because it allows either an increased pay-load or higher performance. As a result, the use of composite sandwich panels has grown due to their light weight and high rigidity. In order to further increase the efficiency of these structures, designers have used different materials in different shapes in the facesheets and in the core. One of the most recent innovations has been the use of a uniform net of carbon fibre/epoxy as the facesheets. In the present study, the optimal design of sandwich plates with heterogeneous, facesheets is treated. The plate mass is minimized, considering the first natural frequency and certain failure loads as constraints. Weight reduction is obtained by defining a nonuniform distribution of composite material in the facesheets. Initially, the facesheets are assumed to be constructed of composite strips in a regular ...
1997-01-01
Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns
Energy Technology Data Exchange (ETDEWEB)
Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar capability, lack of bone-induced artifacts, and high-contrast ...
1997-01-01
Study of osteoporosis using dual energy X-ray absorptiometry
Energy Technology Data Exchange (ETDEWEB)
Dual energy X-ray absorptiometry (Hologic QDR-1000) was used to quantitatively analyze the diagnosis and prevention of osteoporosis. The peak bone mineral density (BMD) of the spine appeared in normal men in their twenties and in normal women in their thirties. There was acceleration of bone loss in the 50 to 60 year age bracket (premenopause and postmenopause) in normal women. On the contrary, the peak BMD of the femoral neck in normal men and women appeared in their twenties after which it decreased slightly with age. Comparison showed that the femoral neck BMD of normal women was lower than that of men throughout all ages. The fracture threshold, 0.756 g/cm[sup 2] for the spine, was obtained by scanning 73 females with spinal fractures, the mean BMDs for L2-L4 at the 90th percentile level were used as the fracture threshold. The fracture threshold of femoral neck fracture was the femoral proximal BMD of the 9th decile. Classification by the Public Welfare Silver Science ...
1992-04-01
International Nuclear Information System (INIS)
The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p ...
2004-09-21
Patients suffering from depression frequently display hyperactivity of the hypothalamic-pituitary-adrenal axis (HPA) resulting in elevated cortisol levels. One main symptom of this condition is anhedonia. There is evidence that exercise training can be used as a rehabilitative intervention in the treatment of depressive disorders. In this scenario, the aim of the present study was to assess the effect of an aerobic exercise training protocol on the depressive-like behavior, anhedonia, induced by repeated dexamethasone administration. The study was carried out on adult male Wistar rats randomly divided into four groups: the "control group" (C), "exercise group" (E), "dexamethasone group" (D) and the "dexamethasone plus exercise group" (DE). The exercise training consisted of swimming (1 h/d, 5 d/wk) for 3 weeks, with an overload of 5% of the rat body weight. Every day rats were injected with either dexamethasone (D/DE) or saline solution (C/E). Proper positive ...
2011-06-15
International Nuclear Information System (INIS)
Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weighted imaging (T_1WI) and T_2 weighted imaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the foreside of cerebral convexity, of which 80.4% (37/46 cases )was predominantly in the subarachnoid space, 8.7% (4/46 cases) in subdural space, 10.9% was subdural coexisted with subarachnoid ...
2006-05-01
Experimental study of lipiodol ultra-fluid. On its signal intensity in MR imaging
Energy Technology Data Exchange (ETDEWEB)
Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 relaxation time of Lipiodol at 1.0 T is probably responsible for the higher intensity at 1.0 T. When MRI is performed after TAE with ...
1988-11-01
British Library Electronic Table of Contents (United Kingdom)
We examined whether or not BMD or bone markers were useful for assessing the risk of vertebral fractures in 248 Japanese men with type 2 diabetes. We analyzed the relationships between bone markers (osteocalcin [OC], bone-specific alkaline phosphatase [BAP], urinary N-terminal cross-linked telopeptide of type-I collagen) or BMD and HbA1c, urinary C-peptide, insulin-like growth factor-I (IGF-I), parathyroid hormone, 1,25(OH)2 vitamin D, and the presence of prevalent vertebral fractures. Multiple regression analysis adjusted for age, body height, weight, duration of diabetes, and serum creatinine showed that serum OC and OC/BAP ratio were correlated negatively with HbA1c (P?P?P?0.05). This association was still significant after additional adjustment for lumbar or femoral neck BMD. Our res...
2009-01-01
PWM applications for the electric railway traction system fed by the AC/DC dual power line
Energy Technology Data Exchange (ETDEWEB)
The latest electronic circuit technology that can be used for the electric railway traction system fed by an AC/DC dual power line was developed. This system consists of reverse conducting GTO thyristors, microprocessors, and DSP`s. In the AC power supply line section, the line converter is controlled by PWM technology to secure a high power factor and reduce the higher harmonic generation of an input current as far as possible. The line converter and motor converter use reverse conducting GTO thyristors. Since these converters are cooled using a heat pipe cooler, they are reduced in size and weight. The electric grounding point of the main power circuit is set to the negative side of the DC line for AC and DC line sections. Therefore, the AC/DC selector switch was simplified in structure. Moreover, the DC input for the auxiliary power supply can be obtained from multiple line converters using diodes. As the result of the actual operational ...
1996-01-01
International Nuclear Information System (INIS)
This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 deg. and stops at N positions uniformly distributed over this 180 deg. . At each stop, the device spins on its own axis 180 deg. and acquires measurements at M positions uniformly distributed over this 180 deg. . For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered backprojection algorithm and a gain of 10%-18% for the iterative algorithms, compared with the situation when a ...
2005-09-01
Optimization of neutron-to-light converter screens for use in real-time neutron radiography
International Nuclear Information System (INIS)
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and phosphorus were studied at MURR. The screen thickness and the neutron absorber/phosphorus ...
1982-04-01
Energy Technology Data Exchange (ETDEWEB)
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of ...
2002-06-01
International Nuclear Information System (INIS)
Central Nervous System (CNS) involvement, whether primary by the Human Immunodeficiency Virus - HIV - itself, or secondary (toxoplasmosis or lymphoma) is remarkably frequent in AIDS, in 40 to 70% of cases, depending upon the author. In order to study the natural history of this illness, a cohort of 25 asymptomatic seropositive patients have been established. Every 6 months these patients undergo biological and clinical examinations, as well as Magnetic Resonance brain scans. After two examinations at a 6 month's interval, the first results are reported. Out of these 25 cases, 9 present anomalies: One patient with diffuse cerebral atrophy and 8 others with high signal intensity areas on T2 weighted sequences, like those of the Multiple Sclerosis. No relationship could be demonstrated between the existence of these lesions and various criteria such as age, sex, risk factors and T4 cells count. The nature of these lesions is not lear. They ...
International Nuclear Information System (INIS)
The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement in 73% and liver involvement in 80% of the ...
2008-10-01
Energy Technology Data Exchange (ETDEWEB)
Fitness, (biometric measurements, reproduction) and behaviour that are ecologically relevant biomarkers in assessing the quality of estuarine sediments were studied by comparing the responses of the polychaete worm Nereis diversicolor - a key species in estuaries - along a pollution gradient. Intersite differences were shown for all the measured parameters: size-weight relationships, energy reserves as glycogen and lipids, sexual maturation patterns, total number of oocytes per female, total and relative fecundity, burrowing behaviour. The physiological and behavioural status of N. diversicolor was consistently disturbed in the larger, most contaminated estuaries (Loire and Seine, Fr.) compared to reference sites (Bay of Bourgneuf, Goyen estuary, Fr.). Many classes of potentially toxic chemicals present in these estuaries most likely contribute to these impairments but food availability may act as a confounding factor, interfering with the ...
2010-01-15
Improvement of FCR-linear tomography using digital image processing
Energy Technology Data Exchange (ETDEWEB)
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image ...
1994-02-01
International Nuclear Information System (INIS)
State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate estimation of the large (factor of 2) changes in the gamma energy deposition-to-source ratio possible near ...
1976-01-01
This cost-effectiveness analysis presents an evaluation of the technical efficiency of pollutant control options for the proposed Effluent Limitations Guidelines and Standards for the Transportation Equipment Cleaning Industry based on Best Available Technology Economically Achievable (BAT) and Pretreatment Standards for Existing Sources (PSES). Section 2 discusses EPA`s cost-effectiveness methodology and identifies the pollutants included in the analysis. This section also presents EPA`s toxic weighting factors for each pollutant and considers the removal efficiency of each pollution control option. Section 3 describes the options evaluated for each subcategory. Section 4 presents the results of the cost-effectiveness analysis. In Section 5, cost-effectiveness values for proposed TEC industry options are compared to cost-effectiveness values for other promulgated rules. Section 6 discusses the two-part cost-reasonableness test for BCT options. ...
1998-05-01
Carbon-bonded carbon fiber insulation for radioisotope space power systems
Energy Technology Data Exchange (ETDEWEB)
A carbon-bonded carbon fiber (CBCF) insulation developed for a radioisotope heat source is made from chopped rayon fiber about 10..mu..m long, which is carbonized and bonded with phenolic resin particles. The CBCF is an excellent lightweight insulating material with a nominal density of 0.2 Mg/m/sup 3/ and a thermal conductivity of 0.24 W/(m-K) in vacuum at 2000/sup 0/C. (Several attributes that make CBCF particularly suitable for the heat source application have been identified.) These include light weight, low thermal conductivity, chemical compatibility, and hightemperature capabilities. The mechanical strength of CBCF insulation is satisfactory for the application. The basic fabrication technique was refined to eliminate undesirable large pores and cracks often present in materials fabricated by earlier techniques. Also, processing was scaled up to increase the fabrication rate by a factor of 10. The specific properties of the CBCF were ...
1985-05-01
Carbon-bonded carbon fiber insulation for radioisotope space power systems
Energy Technology Data Exchange (ETDEWEB)
A carbon-bonded carbon fiber (CBCF) insulation developed for a radioisotope heat source is made from chopped rayon fiber about 10 ..mu..m in diameter and 250 ..mu..m long, which is carbonized and bonded with phenolic resin particles. The CBCF is an excellent lightweight insulating material with a nominal density of 0.2 Mg/m/sup 3/ and a thermal conductivity of 0.24 W/(m-K) in vacuum at 2000/sup 0/C. Several attributes that make CBCF particularly suitable for the heat source application have been identified. These include light weight, low thermal conductivity, chemical compatibility, and high-temperature capabilities. The mechanical strength of CBCF insulation is satisfactory for the application. The basic fabrication technique was refined to eliminate undesirable large pores and cracks often present in materials fabricated by earlier techniques. Also, processing was scaled up to increase the fabrication rate by a factor of 10. The specific ...
1985-05-01
Body dose conversion factors for computerized tomography
International Nuclear Information System (INIS)
While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional ...
1980-10-31
A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)
International Nuclear Information System (INIS)
T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is better with MRT, offering diagnostic advantages for MRT. ...
FIBROUS MONOLITH WEAR RESISTANT COMPONENTS FOR THE MINING INDUSTRY
Energy Technology Data Exchange (ETDEWEB)
A set of materials property data for potential wear resistant materials was collected. These materials are designated for use as the ''core'' materials in the Fibrous Monolith structure. The material properties of hardness, toughness, thermal conductivity and cost were selected as determining factors for material choice. Data for these four properties were normalized, and weighting factors were assigned for each property to establish priority and evaluate the effects of priority fluctuation. Materials were then given a score based on the normalized parameters and weighting values. Using the initial estimates for parameter priority, the highest ranking material was tungsten carbide, with diamond as the second ranked material. Several materials were included in the trade study, and five were selected as promising ''core'' materials to ...
2001-08-15
Reprocessed uranium fuel fabrication in Japan
International Nuclear Information System (INIS)
Nuclear fuel vendors in Japan are now studying reprocessed uranium (RepU) fuel in order to prepare for full scale utilization in the future. Separate studies are made for PWR and BWR fuel. The study consists of 2 phrases. The purposes of phase-1 are to understand various RepU characteristics in the fuel fabrication process, to analyze the core characteristics by loading RepU assemblies, to solve the problems clarified in the study, and to collect basic data for licensing. In phase-2, the effects of impurities on the fabrication process will be evaluated, and the safety of RepU fuel manufacturing will be confirmed with a RepU fuel fabrication campaign in 1990. The neutronic data will be collected after insertion into power reactors, and the data will be used to verify plant safety for full utilization of RepU in the future. This paper summarizes the phase-1 study results. 1. RepU Characteristics. The internal and external radiation exposures due to nuclide ...
1990-12-01
Load calculation and system evaluation for electric vehicle climate control
Energy Technology Data Exchange (ETDEWEB)
This paper presents an analysis of the applicability of alternative systems for electric vehicle (EV) heating and air conditioning (HVAC). The paper consists of two parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can provide the desired cooling and heating in EVs. These systems are ranked according to their overall weight The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation. The system with the minimum overall weight is considered to be the best, because minimum vehicle weight decreases the energy required for propulsion, and therefore increases the vehicle range. Three systems are considered as the best choices for EV HVAC. These are, vapor compression, ice storage and adsorption ...
1994-09-12
The Use of Medical Images in Planning and Delivery of Radiation Therapy
UK PubMed Central (United Kingdom)
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
1997-09-01
Animal Models for Radiation Injury, Protection and Therapy
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
Differential effects of chronic ingestion of tritiated water on prenatal brain development
International Nuclear Information System (INIS)
Female rats were given tritiated drinking water (3 microCi/ml) from 30 days before mating up to and throughout pregnancy. At this low dose, the course and the outcome of pregnancy were normal. The differences between newborn body and cerebral weights of the treated rats and those of control animals were on the borderline of significance. In contrast, cerebral DNA and cerebral protein were highly significantly lower. In 30-35% of the treated population the DNA and protein values were more than 2 standard deviations (SD) below the mean values for the control population. Thus the number of the progeny of the mothers exposed to tritiated water that were considered to have outstandingly low levels of DNA and protein was 14-17 times greater than in the control group. The irradiated population also had 3-5% of severely affected individuals with cerebral DNA and protein values more than 2 SD below the mean of the experimental population. However, even in this irradiated ...
Energy Technology Data Exchange (ETDEWEB)
A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation decay time. We have ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture flowing out of the wood, ...
1982-04-01
International Nuclear Information System (INIS)
The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture flowing out of the wood, ...
1982-01-01
Intergalactic dust and its photoelectric heating
We have examined the dust photoelectric heating in the intergalactic medium (IGM). The heating rate in a typical radiation field of the IGM is represented by $\\Gamma_{\\rm pe} = 1.2\\times10^{-34}$ erg s$^{-1}$ cm$^{-3}$ $({\\cal D}/10^{-4})(n_{\\rm H}/10^{-5} {\\rm cm^{-3}})^{4/3} (J_{\\rm L}/10^{-21} {\\rm erg s^{-1} cm^{-2} Hz^{-1} sr^{-1}})^{2/3} (T/10^4 {\\rm K})^{-1/6}$, where ${\\cal D}$ is the dust-to-gas mass ratio, $n_{\\rm H}$ is the hydrogen number density, $J_{\\rm L}$ is the mean intensity at the hydrogen Lyman limit of the background radiation, and $T$ is the gas temperature, if we assume the new X-ray photoelectric yield model by Weingartner et al. (2006) and the dust size distribution in the Milky Way by Mathis, Rumpl, & Nordsieck (1977). This heating rate dominates the HI and HeII photoionization heating rates when the hydrogen number density is less than $\\sim10^{-6}$ cm$^{-3}$ if ${\\cal D}=10^{-4}$ which is 1% of that ...
2008-01-01
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
Energy Technology Data Exchange (ETDEWEB)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
1990-10-01
Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro
International Nuclear Information System (INIS)
Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels of irradiation (500 ...
Energy Technology Data Exchange (ETDEWEB)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were ...
2010-07-01
Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy
International Nuclear Information System (INIS)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were ...
2010-08-18
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may ...
1996-12-31
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...
1988-10-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be ...
2010-06-15
International Nuclear Information System (INIS)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could be reduced in the last ...
2010-06-01
Electron-ion recombination of neutral iron
Energy Technology Data Exchange (ETDEWEB)
The total and state-specific electron-ion recombination rate coefficients are obtained for FeI. The calculations are carried out using a new ab initio method that incorporates both the radiative and the dielectronic recombination processes in an unified and self-consistent manner. The computations employ the close coupling approximation and the R-matrix method from atomic collision theory. A 52 state close coupling eigenfunction expansion dominated by the states of the ground 3d{sup 6}4s and excited 3d{sup 7}, 3d{sup 6}4p, 3d{sup 5}4s{sup 2}, and 3d{sup 5}4s4p configurations of FeII are used in the present calculations. The important electron correlation and radiation damping effects are included via explicit coupling of autoionization and radiative channels. This is the first detailed atomic calculation for the recombination rates for FeI. The present rates are considerably higher than the radiative ...
1997-04-01
Development of radiological emergency preparedness technology
Energy Technology Data Exchange (ETDEWEB)
Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological microanalytic methods for assessing the ...
2000-04-01
Energy Technology Data Exchange (ETDEWEB)
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic ...
1989-08-15
Use plan for demonstration radioactive-waste incinerator
Energy Technology Data Exchange (ETDEWEB)
The University of Maryland at Baltimore was awarded a grant from the Department of Energy to test a specially modified incinerator to burn biomedical radioactive waste. In preparation for the incinerator, the Radiation Safety Office devised a comprehensive plan for its safe and effective use. The incinerator plan includes a discussion of regulations regarding on-site incineration of radioactive waste, plans for optimum use in burning four principal waste forms, controlled air incineration technology, and standard health physics safety practices; a use plan, including waste categorization and segregation, processing, and ash disposition; safety procedures, including personnel and area monitoring; and methods to evaluate the incinerator's effectiveness by estimating its volume reduction factors, mass and activity balances, and by determining the cost effectiveness of incineration versus commercial shallow land burial.
1982-04-01
The radon therapy - radon inhalatorium in Kowary
International Nuclear Information System (INIS)
In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)
The Effective Weak Mixing Angle In the MSSM
The predictions of the MSSM are discussed in the light of recent LEP and SLD precision data. The full supersymmetric one loop corrections to the effective weak mixing angle, experimentally determined in LEP and SLD experiments, are considered. It is demonstrated, both analytically and numerically, that, potentially dangerous, large logarithmic sparticle corrections are cancelled. The relative difference factor \\Delta k between the mixing angle defined as a ratio of couplings and the experimentally obtained angle is discussed. It is found that \\Delta k is dominated by the oblique corrections, while the non-oblique overall supersymmetric EW and SQCD corrections are negligible. The comparison of the MSSM with radiative electroweak symmetry breaking to the LEP precision data indicates that rather large values of the soft breaking parameter M_{1/2} in the region greater than 500 GeV are preferred.
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
Simple frameworks have been developed for estimating the utilization potential of: (a) solar photovoltaic (SPV) pumps; (b) windmill pumps; (c) producer gas based dual fuel engine pumps; and (d) biogas based dual fuel engine pumps for irrigation water pumping in India. The approach takes into account factors such as: solar radiation intensity, wind speed, availability of bovine dung and agri-residues, and their alternative uses, ground water requirements for irrigation and its availability, affordability, and propensity of the users to invest in renewable energy devices, etc. SPV pumps are estimated to have the maximum utilization potential in India, followed by windmill pumps. (author)
2007-05-15
Radiation imposed limits on superconducting magnets: A data base for copper stabilizers
Energy Technology Data Exchange (ETDEWEB)
Two of eight differently prepared copper stabilizer samples, previously irradiated in the RTNS-II at LLNL, the IPNS-1 and the BSR at ORNL, have been irradiated to a fluence of 1.33 /times/ 10/sup 22/ n/m/sup 2/ at RTNS-II. During the course of the irradiation the samples were periodically removed (without warming) for measurements of the transverse magnetoresistance and returned for continued irradiation. This experiment extends the range of neutron-irradiation-induced resistivity by a factor of five over the previous experiments. A simple model is developed which reproduces the magnetoresistance results of all the experiments to an accuracy of 2.5%. 13 refs., 6 figs.
1987-10-28
Energy Technology Data Exchange (ETDEWEB)
Ozone plays a critical role in both the chemistry and radiation balance of the troposphere. Understanding the factors controlling tropospheric ozone levels is critical to our understanding of a variety of issues in global chemistry and climate change. Chlorine atoms have the potential to contribute significantly to the ozone balance in the free troposphere. They can react directly with ozone or alternately, with organics and may actually lead to the formation of ozone in the presence of sufficient NO. Reactions of alkali halides in sea salt particles are a potential source of atomic chlorine, hence reactions of these alkali halides, especially those producing precursors to atomic chlorine, are of great interest. Finally, the mechanisms, intermediates and products of the Cl-biogenic reactions are unknown; these could serve as unique markers of chlorine atom chemistry in the troposphere, and hence are important to define.
1994-11-15
Inflation and reheating in Bianchi type-IX cosmology
Energy Technology Data Exchange (ETDEWEB)
Within the framework of the Bianchi type-IX homogeneous space, we set up a system of coupled equations for the cosmic scale factors, scalar field, and radiative energy density. At the tree level, the equations are written in a self-consistent, Hartree-Fock form. For phi/sup 4/ theory, the system of nine first-order differential equations is solved numerically for a varying ratio of the energy of anisotropy to the vacuum energy. As the vacuum energy increases, there appears to be less reheating, since the energy of anisotropy is more efficiently converted into isotropic expansion. If the energy of anisotropy is large enough, the inflationary phase is prevented. In this case, a series of cosmological phase transitions will take place each time the square of the effective mass changes its sign.
1985-02-15
Inflation and reheating in Bianchi type-IX cosmology
International Nuclear Information System (INIS)
Within the framework of the Bianchi type-IX homogeneous space, we set up a system of coupled equations for the cosmic scale factors, scalar field, and radiative energy density. At the tree level, the equations are written in a self-consistent, Hartree-Fock form. For phi"4 theory, the system of nine first-order differential equations is solved numerically for a varying ratio of the energy of anisotropy to the vacuum energy. As the vacuum energy increases, there appears to be less reheating, since the energy of anisotropy is more efficiently converted into isotropic expansion. If the energy of anisotropy is large enough, the inflationary phase is prevented. In this case, a series of cosmological phase transitions will take place each time the square of the effective mass changes its sign.
Induction linac-driven free-electron lasers: Status and future prospects
Energy Technology Data Exchange (ETDEWEB)
The high repetition rate and low single-pass gain inherent in an rf-driven Free Electron Laser (FEL) dictate that the laser system be configured as an oscillator. This allows the laser's electric field to build up over many passes around a high Q cavity. By way of contrast, the high-current capability of the Induction Linac (IL) system permits high single-pass optical gain, but the relatively low duty factor precludes oscillator operation; the pulses are neither long enough nor often enough to permit a field to accumulate in a cavity. The IL is thus configured as a MOPA (master oscillator/power amplifier) with a conventional laser serving as the MO. This report concentrates on the status of IL-driven FEL research at LLNL and gives a description of several applications for the high-peak-power radiation produced by an induction linac FEL.
1987-01-11
International Nuclear Information System (INIS)
Presented here is the calculation of the diffusion of radionuclides from the Daya Bay Nuclear Power Plant under normal operation on the basis of Gaussian model. The model is modified partially considering practical situation, and monitoring meteorological data are adopted. By using the AIRDOS-EPA computer code, the average annual ground-level concentration distribution of radionuclides from Daya Bay Nuclear Power Plant in 2001 was obtained, the atmospheric dispersion factor and ground deposition rate were also acquired. These calculated results can provide information for understanding the effect on radiation environment due to Daya Bay Nuclear Power Plant under normal operation. (authors)
2007-11-01
Are There Enough Ionizing Photons to Reionize the Universe by z=6?
An estimate for the number of ionizing photons per baryon as a function of redshift is computed based on the plausible extrapolation of the observed galaxy UV luminosity function and the latest results on the properties of the escape fraction of ionizing radiation. It is found that, if the escape fraction for low mass galaxies (Mtot<10^{11}Msun) is assumed to be negligibly small, as indicated by numerical simulations, then there are not enough ionizing photons to reionize the universe by z=6 for the cosmology favored by the WMAP 3rd year results, while the WMAP 1st year cosmology is marginally consistent with the reionization requirement. The escape fraction as a function of galaxy mass would have to be constant to within a factor of two for the whole mass range of galaxies for reionization to be possible within the WMAP 3rd year cosmology.
2007-01-01
The dependence of radiation hardening and embrittlement on irradiation temperature
International Nuclear Information System (INIS)
Assessments of the hardening and embrittlement of pressure vessel steels and welds as a function of neutron dose use trend curves derived from surveillance programs and accelerated irradiation data. A temperature dependent factor is incorporated for assessing vessel locations operating at different temperatures. As hardening and embrittlement arise from the sum of matrix damage and copper impurity precipitation, the influence of irradiation temperature on each process needs to be established. For irradiations performed below #approx# 300 C recent data shows that the dose-dependent growth of copper precipitates ceases at a mean diameter of about 2 nm that also corresponds to peak hardening and embrittlement by copper. For doses beyond this peak copper dose the property-dependence on irradiation temperature can be identified with that of matrix damage alone. An analysis of several experiments on plate steels, performed at differing irradiation temperatures, has ...
1994-06-20
Results of radon concentration measurements in some regions of Russia
Energy Technology Data Exchange (ETDEWEB)
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal ...
1996-01-01
Results of radon concentration measurements in some regions of Russia
International Nuclear Information System (INIS)
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for ...
Fading of irradiated blue-colored pearls. [Gamma radiation
Energy Technology Data Exchange (ETDEWEB)
The fading of irradiated and natural blue-colored pearls was investigated in this experiment. Thirty natural blue-colored pearls and sixty irradiated blue-colored pearls were used. Some of them were placed at a light position of RT. Another pearls were placed at a dark position of 50/sup 0/C. The irradiated pearls placed at a light position of RT didn't show remarkable fading in their color in 294 days. But the natural blue-colored pearls showed a little recovery from 4% to 8% in reflection factors in 223 days at RT. The irradiated pearls placed at a dark position of 50/sup 0/C showed the recovery from 9% to 14% in 264 days independently of irradiation times. The natural blue-colored pearls also showed the bleaching from 5% to 10% in reflection factor in 86 days at 50/sup 0/C. Both irradiated and natural blue-colored pearls hardly showed their remarkable changes in their chromaticities independently of temperatures.
1982-03-01
Radwaste Drum Assay Technology by Segmented Gamma Scanning System
Energy Technology Data Exchange (ETDEWEB)
Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential peak absorption, mean density ...
2009-01-15
D & D screening risk evaluation guidance
Energy Technology Data Exchange (ETDEWEB)
The Screening Risk Evaluation (SRE) guidance document is a set of guidelines provided for the uniform implementation of SREs performed on decontamination and decommissioning (D&D) facilities. Although this method has been developed for D&D facilities, it can be used for transition (EM-60) facilities as well. The SRE guidance produces screening risk scores reflecting levels of risk through the use of risk ranking indices. Five types of possible risk are calculated from the SRE: current releases, worker exposures, future releases, physical hazards, and criticality. The Current Release Index (CRI) calculates the current risk to human health and the environment, exterior to the building, from ongoing or probable releases within a one-year time period. The Worker Exposure Index (WEI) calculates the current risk to workers, occupants and visitors inside contaminated D&D facilities due to contaminant exposure. The Future Release Index (FRI) calculates the hypothetical risk of ...
1995-09-01
International Nuclear Information System (INIS)
Although the intracellular ultrastructural processing of epidermal growth factor (EGF) and its receptor have been described in cell culture systems, very few studies have examined this phenomenon in intact tissues. We have examined the ultrastructural and biochemical handling of ["1"2"5I]EGF in the epidermis and hair follicle bulb of intact, viable, 3- to 5-day-old rat skin the EGF receptor distribution of which has already been documented and in which EGF has been shown to be biologically active. After incubation of explants with 10 nM ["1"2"5I]EGF for 2.5 h at 25 degrees or 37 degrees C, radiolabel was detected over the basal cells of the epidermis and hair follicle outer root sheath, confirming previous light microscope observations. More specifically, silver grains were observed near coated and uncoated plasma membrane and coated membrane invaginations, Golgi apparatus, lysosomal structures, and nuclei. Sodium azide inhibited internalization of label, whereas a ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
Although the intracellular ultrastructural processing of epidermal growth factor (EGF) and its receptor have been described in cell culture systems, very few studies have examined this phenomenon in intact tissues. We have examined the ultrastructural and biochemical handling of (/sup 125/I)EGF in the epidermis and hair follicle bulb of intact, viable, 3- to 5-day-old rat skin the EGF receptor distribution of which has already been documented and in which EGF has been shown to be biologically active. After incubation of explants with 10 nM (/sup 125/I)EGF for 2.5 h at 25 degrees or 37 degrees C, radiolabel was detected over the basal cells of the epidermis and hair follicle outer root sheath, confirming previous light microscope observations. More specifically, silver grains were observed near coated and uncoated plasma membrane and coated membrane invaginations, Golgi apparatus, lysosomal structures, and nuclei. Sodium azide inhibited internalization of label, ...
1987-03-01
Energy Technology Data Exchange (ETDEWEB)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy in theoretical ...
2007-12-15
International Nuclear Information System (INIS)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy in theoretical ...
2007-12-01
International Nuclear Information System (INIS)
... radiation effects human populations low dose irradiation neoplasms radiation
1980-01-01
Radiation protection and the management of radioactive waste in the oil and gas industry
Radiation protection and the management of radioactive waste in the oil and gas industry
2003-01-01
Influence of germanium and oxygen impurities on the radiation hardening of monocrystalline silicon
International Nuclear Information System (INIS)
... defects doped materials germanium infrared radiation monocrystals neutron
Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles
International Nuclear Information System (INIS)
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
1980-06-01
International Nuclear Information System (INIS)
... pathological changes patients radiation protection radiotherapy diseases
1982-10-25
Contribution to the radiation preparation of wood-plastic materials. Pt. 7
International Nuclear Information System (INIS)
... odd nuclei organic compounds radiation effects radioisotopes synthesis
1974-01-01
Contribution to the radiation preparation of wood-plastic materials. Pt. 6
International Nuclear Information System (INIS)
... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.
1974-01-01
Contribution to the radiation preparation of wood-plastic materials Pt. 3
International Nuclear Information System (INIS)
... compounds plants radiation effects radioisotopes reaction kinetics trees
1974-01-01
duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...
The Use of Weighting in Periodicity Searches in All-Sky Monitor Data: Applications to the GLAST LAT
Energy Technology Data Exchange (ETDEWEB)
The light curves produced by all-sky monitors, such as the Rossi X-ray Timing Explorer All-Sky Monitor and the Swift Burst Alert Telescope (BAT), generally have non-uniform error bars. In searching for periodic modulation in this type of data using power spectra it can be important to use appropriate weighting of data points to achieve the best sensitivity. It was recently demonstrated that for Swift BAT data a simple weighting scheme can actually sometimes reduce the sensitivity of the power spectrum depending on source brightness. Instead, a modified weighting scheme, based on the Cochran semi-weighted mean, gives improved results independent of source brightness. We investigate the benefits of weighting power spectra in period searches using simulated GLAST LAT observations of {gamma}-ray binaries.
2009-06-25
Systematics of average radiative width of heavy nuclides
Energy Technology Data Exchange (ETDEWEB)
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
1999-03-01
International Nuclear Information System (INIS)
Purpose: Patients with ataxia-telangiectasia (A-T) show greatly increased radiation sensitivity and cancer predisposition. Family studies imply that the otherwise clinically silent heterozygotes of this autosomal recessive disease run a 3.5 to 3.8 higher risk of developing cancer. In vitro studies suggest moderately increased cellular radiation sensitivity of A-T carriers. They may also show elevated clinical radiosensitivity. We retrospectively examined patients who presented with severe adverse reactions during or after standard radiation treatment for mutations in the gene responsible for A-T, ATM, considering a potential means of future identification of radiosensitive individuals prospectively to adjust dosage schedules. Material and Methods: We selected 20 cancer patients (breast, 11; rectum, 2; ENT, 2; bladder, 1; prostate, 1; anus, 1; astrocytoma, 1; Hodgkins lymphoma, 1) with Grade 3 to 4 (RTOG) acute and/or late ...
1999-07-15
Internalized societal attitudes moderate the impact of weight stigma on avoidance of exercise.
Experiences with weight stigma negatively impact both psychological outcomes (e.g., body dissatisfaction, depression) and behavioral outcomes (e.g., dieting, exercise). However, not everyone is equally affected by experiences with weight stigma. This study examined whether internalized societal attitudes about weight moderated the impact of weight stigma. Adult participants (n = 111) completed measures of experiences with weight stigma, as well as two indexes of internalized societal attitudes (the moderators): Internalized anti-fat attitudes and internalization of societal standards of attractiveness. Psychological outcomes included self-esteem, body dissatisfaction, drive for thinness, and bulimic symptoms; behavioral outcomes included avoidance of exercise and self-reported exercise behavior. Weight stigma was positively correlated with body dissatisfaction, ...
2010-10-14
DEFF Research Database (Denmark)
OBJECTIVE: To evaluate the association between fatty acid (alpha-linolenic acid (ALA), EPA, DHA, palmitic, stearic, oleic, linoleic and arachidonic acids) intake and prospective weight change in the Heidelberg cohort of the European Prospective Investigation into Cancer and Nutrition. DESIGN: Prospective cohort study with mean follow-up time of 6.5 years. In a total of 9182 men and 10867 women aged 35 to 64 years, from body weight measurement at recruitment and calibrated body weight during follow-up, weight change was expressed as mean annual weight change relative to baseline weight (%/year) and categorised into four groups (weight loss, or =2.5 to or =7.5%/5 years). Energy-adjusted dietary fatty acid intake data were estimated from the FFQ completed at baseline. Multivariate linear regression models as well as multinomial logistic ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: Reconstruction of organ doses of selected organs and tissues from radiographic settings and exposure data collected during chest X-ray examinations of children of various age groups performed in Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007. Materials and Method: The dosimetric data of all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 119 150 chest radiographs of all age groups. Reconstruction of organ doses in 40 organs and tissues in X-ray examinations of the chest was performed based on the conversion factor concept. Results: The radiation exposure of organs in projection radiography is determined by the exact site of the organs relative to the edges of the X-ray field and ...
2009-05-15
Molecular targeted treatment and radiation therapy for rectal cancer
Energy Technology Data Exchange (ETDEWEB)
Background: EGFR (epidermal growth factor receptor) and VEGF (vascular endothelial growth factor) inhibitors confer clinical benefit in metastatic colorectal cancer when combined with chemotherapy. An emerging strategy to improve outcomes in rectal cancer is to integrate biologically active, targeted agents as triple therapy into chemoradiation protocols. Material and methods: cetuximab and bevacizumab have now been incorporated into phase I-II studies of preoperative chemoradiation therapy (CRT) for rectal cancer. The rationale of these combinations, early efficacy and toxicity data, and possible molecular predictors for tumor response are reviewed. Computerized bibliographic searches of Pubmed were supplemented with hand searches of reference lists and abstracts of ASCO and ASTRO meetings. Results: the combination of cetuximab and CRT can be safely applied without dose compromises of the respective treatment components. Disappointingly low ...
2009-06-15
Energy Technology Data Exchange (ETDEWEB)
There is a continuing need to understand dose-response relationships for ionizing radiation in order to protect the health of the public and nuclear workers from undue exposures. However, relatively few human populations have been exposed to doses of radiation high enough to cause observable, long-term health effects from which to derive dose-response relationships. This is particularly true for internally deposited radionuclides, although much effort has been devoted to epidemiological studies of the few types of exposures available, including lung cancers in uranium miners form the inhalation of the radioactive decay products of Ra, liver cancers in patients injected with Thorotrast X-ray contrast medium containing Th, bone cancers in radium dial painters who ingested Ra, and bone cancers in patients who received therapeutic doses of Ra. These four types of exposures to internally deposited radionuclides provide a basis for understanding the ...
1995-12-01
UK PubMed Central (United Kingdom)
PurposeThis study aimed to evaluate weight and height status and their relationship with psychological problems among elementary schoolchildren.Materials and...Full Text Available
2009-06-30
Gestational Weight Gain and Risk of Gestational Diabetes Mellitus
UK PubMed Central (United Kingdom)
OBJECTIVETo estimate the relationship between the rate of gestational weight gain before the 50-g, 1-hour oral glucose challenge test screening for gestational diabetes...Full Text Available
2010-03-01
UK PubMed Central (United Kingdom)
BackgroundObesity has reached epidemic proportions in the United States. It is implicated in the development of a variety of chronic disease states and is associated with increased...Full Text Available
EPA On-line Tools for Site Assessment Calculation | Ecosystems...
MWo = average molecular weight of fuel est. 105 g/mole for gasoline est. 165 g/mole for Jet fuel est. 230 g/mole for diesel fuel MWX = molecular weight of selected chemical...
2011-01-19
Triatomic Centrosymmetric Crystals
... and Refining Company (ASARCO) and were 99.999 + weight percent pure as jW determined by the suppliers spectrographic analyses. ...
1972-05-31
Energy Technology Data Exchange (ETDEWEB)
The article describes the Solair 1 solar cell-powered aircraft. Measures to reduce the weight of the craft are cited.
1983-03-01
Multiplicity formulas for a class of representations of affine Kac-Moody algebras
Energy Technology Data Exchange (ETDEWEB)
Simple recursion formulas are derived for the multiplicities of the dominant weight vectors appearing in a class of irreducible highest weight representations of the indecomposable affine Kac-Moody algebras. This class is characterized by the appearance of exactly two distinct infinite sequences of dominant weight vectors. The general procedure used for the enumeration of these representations and for the derivation of the corresponding multiplicity formulas is that presented by Capps for the analysis of those irreducible representations containing exactly one such infinite sequence. This procedure includes the classification of representations in terms of congruence and the identification of Weyl orbits by the norm of the dominant weight. Some of the results presented have application to physical theories such as string field theories.
1992-01-01
General Toxicity/Reproductive Toxicity Screen of Modular ...
... BODY WEIGHT, FEMALES, SEX, ORGANS(ANATOMY), NITROGUANIDINE, NITROGLYCERIN, COMBUSTIBLE CARTRIDGE CASES, FERTILITY. ...
1996-01-01
Four Forces on a Rocket - NASA
On an airplane, the lift force (the aerodynamic force perpendicular to the flight direction) is used to overcome the weight. On a rocket, thrust is used in opposition ...
Aqueous drilling fluids containing fluid loss additives
Energy Technology Data Exchange (ETDEWEB)
This patent describes an aqueous clay containing drilling fluid having present in an amount sufficient to reduce fluid loss of the drilling fluid, a copolymer of (1) from about 80% to about 98% by weight of acrylic acid and (2) from about 2% to about 20% by weight of itaconic acid. The copolymer has a weight average molecular weight of between about 50,000 to about 1,000,000, being in its free acid or partially or completely neutralized salt form and being at least water dispersible.
1987-03-03
Energy Technology Data Exchange (ETDEWEB)
Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of irradiated specimens were studied using transmission electron microscopy (TEM) and a nanoindentation ...
1997-09-01
Predictive model of electron-beam-induced flashblindness. Final report, November 1983-October 1984
Energy Technology Data Exchange (ETDEWEB)
The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these conversion factors, ...
1985-03-01
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 A/cm"2 (R/min); the ...
1993-10-13
International Nuclear Information System (INIS)
Background and purpose: In order to investigate the feasibility, toxicity and antitumor efficacy of hyperfractionated radiation therapy, 37 adult patients with incompletely resected supratentorial low-grade glioma were entered into a phase II study. Materials and methods: The radiation therapy dose was 55 Gy in 50 fractions in 25 treatment days over 5 weeks to the tumor plus a 2-cm margin, with an additional 17.6 Gy given in 16 fractions in 8 treatment days over 1.5 weeks to the tumor plus a 1-cm margin, using 1.1 Gy b.i.d. fractionation with a 6 h interfraction interval. The total tumor dose was 72.6 Gy in 66 fractions in 33 treatment days over 6.5 weeks. Results: The median survival time (MST) for all 37 patients has not yet been attained, while 5- and 7-year survival rates were 75% and 69%, respectively. The median time to tumor progression (MTP) has also not yet been attained, while 5- and 7-year progression-free survival (PFS) rates were ...
1998-10-01
Energy Technology Data Exchange (ETDEWEB)
The linear/supralinear behaviour of the TL dose response in LiF:Mg,Ti (TLD-100) and its dependence on ionisation density is a fairly unique phenomenon which cannot be explained by conventional atomic 'conduction band/valence band' kinetic models. The Track Interaction Model (TIM) provides the microscopic framework which, when coupled with other appropriate physical mechanisms (spatial localisation of traps and recombination centres, competing centres, variations in the capture cross sections with temperature, etc.) can be used to describe all the dominant features of the TL supralinearity of LiF:Mg,Ti and similar TL systems. The unique feature of the TIM applied to alpha particles is that it is an integral approach with only one free parameter, the average charge carrier migration distance in the luminescence recombination stage. Although the TIM provides a comprehensive description of the mechanisms underlying supralinearity in TLD-100, definitive unambiguous proof ...
1993-01-01
Weight-control behaviors and subsequent weight change among adolescents and young adult females123
UK PubMed Central (United Kingdom)
Background: Little is known about the effectiveness of behavioral strategies to prevent long-term weight gain among adolescents and young adults.Objective: The objective...Full Text Available
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Ammonium nitrate shale oil explosives are provided which are effective, powerful, inexpensive, and safe. The explosives contain about 2% to 10% by weight shale oil and about 90% to 98% by weight ammonium nitrate. The shale oil can be whole shale oil or heavy shale oil containing from 0.1% to 65% by weight oil shale dust. The ammonium nitrate is preferably in the form of explosive grade ammonium nitrate prills.
1984-10-09
Quasifinite highest weight modules over the super W 1 + #infinity#algebra
International Nuclear Information System (INIS)
We study quasifinite highest weight modules over the supersymmetric extension of the W_1_+_#infinity# algebra on the basis of the analysis by Kac and Radul. We find that the quasifiniteness of the modules is again characterized by polynomials, and obtain the differential equations for highest weights. The spectral flow, free field realization over the (B, C)-system, and the embedding into gl(#infinity#vertical stroke #infinity#) are also presented. (orig.).
1995-01-01
Hamming Weights in Irreducible Cyclic Codes
Irreducible cyclic codes are an interesting type of codes and have applications in space communications. They have been studied for decades and a lot of progress has been made. The objectives of this paper are to survey and extend earlier results on the weight distributions of irreducible cyclic codes, present a divisibility theorem and develop bounds on the weights in irreducible cyclic codes.
2011-01-01
UK PubMed Central (United Kingdom)
A self-selected sample of 417 urban and 379 rural preschool children attending the under-5s clinics was weighed in Sierra Leone. The individual weights were related to the weight-for-age Harvard 3rd...Full Text Available
1977-05-01
International Nuclear Information System (INIS)
The authors compared unenhanced and contrast-enhanced fast MRI and Computerized Tomography in the detection of liver metastases. Eleven patients with single or multiple hepatic lesions (42 in all) were submitted to V and magnetic resonance studies; T1- and T2- weighted TSE, T2-weighted TSE with fat suppression, unenhanced breath-hold TFE and early or delayed enhanced breath-hold TFE images were acquired with a 1.5 T superconductive magnet (Philips NT). The quantitative analysis of all magnetic resonance images was performed for contrast/noise ratio (CNR) and number of detected lesions; magnetic resonance and Computerized Tomography images were also compared qualitatively for lesion conspicuity, anatomical structure identification and artifacts. The results were compared with Student's test. Early enhanced breath-hold TFE was statistically superior to T1-weighted TSE (p = .0009), T2-weighted TSE (p = ...
1997-01-01
Development of internal dose estimation software on radiation protection
International Nuclear Information System (INIS)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
2008-10-01
Application of dose factors for decay chains
International Nuclear Information System (INIS)
... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor
The Results of Postoperative Radiation Therapy for Perihilar Cholangiocarcinoma
International Nuclear Information System (INIS)
The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months (range, 6 to 45 months). The 3-year overall ...
2009-12-01
Salt decontamination demonstration test results
International Nuclear Information System (INIS)
The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a ...
Radiation therapy for gastrointestinal lymphomas: indications and techniques
International Nuclear Information System (INIS)
Gastrointestinal lymphomas are almost exclusively of a non Hodgkin's type. The Western form is characterized by a higher incidence of stomach location (50 %), a MALT type (mucosa associated lymphoid tissue) (40 %), a B-cell type (90 %), and a high grade (55 %). Chronic infection with Helicobacter pylori is an important risk factor. Mediterranean lymphomas form a particular clinical and pathological entity with diffuse involvement of the small bowel and are frequently being associated with a chronic malabsorption disorder. Eradication of Helicobacter pylori in early lymphomas, and the use of tetracyclines in early Mediterranean lymphomas, have been shown to induce durable remissions. For more advanced gastric lymphomas, treatment usually consists of anthracycline-based chemotherapy followed by involved field radiotherapy. Surgery is usually reserved for complications such as perforation or bleeding, or in some selected cases for salvage after failure of non-surgical ...
The evaluation of risks from radiation
International Nuclear Information System (INIS)
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
1977-01-01
International Nuclear Information System (INIS)
Portuguese Sep-Oct 1996 p. 571 Brazil Campos, Patricia Sao Paulo
Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine
... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...
The principles of radionuclide excitation of X-ray fluorescence radiation and its application in
1972-01-01
This investigation describes the technique for the detection of the X-ray fluorescent radiation
1972-01-01
International Nuclear Information System (INIS)
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...
1993-01-01
Characterization of an add-on multileaf collimator for electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or ...
2008-02-21
On the two weighting scheme for {delta}f collisional transport simulation
Energy Technology Data Exchange (ETDEWEB)
The validity is given to the newly proposed two weighting {delta}f scheme (Wang et al., Research Report of National Institute for Fusion Science NIFS-588, 1999) for collisional or neoclassical transport calculations, which can solve the drift kinetic equation taking account of effects of steep plasma gradients, large radial electric field, finite banana width, and the non-standard orbit topology near the axis. The marker density functions in weight equations are successively solved by using the idea of {delta}f method and a hierarchy of equations for weight and marker density functions is obtained. These hierarchy equations are solved by choosing an appropriate source function for each marker density. Thus the validity of the two weighting {delta}f scheme is mathematically proved. (author)
1999-08-01
Morphological dilation image coding with context weights prediction
This paper proposes an adaptive morphological dilation image coding with context weights prediction. The new dilation method is not to use fixed models, but to decide whether a coefficient needs to be dilated or not according to the coefficient's predicted significance degree. It includes two key dilation technologies: 1) controlling dilation process with context weights to reduce the output of insignificant coefficients, and 2) using variable-length group test coding with context weights to adjust the coding order and cost as few bits as possible to present the events with large probability. Moreover, we also propose a novel context weight strategy to predict coefficient's significance degree more accurately, which serves for two dilation technologies. Experimental results show that our proposed method outperforms the state of the art image coding algorithms available today.
2010-01-01
Microdialysis unit for molecular weight separation
Energy Technology Data Exchange (ETDEWEB)
The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, or (4) ...
1999-09-21
Energy Technology Data Exchange (ETDEWEB)
The effects of group structures and weighting functions on neutron penetration through a thick Na-Fe geometry are studied. The recommended broad-group (61-neutron/23-gamma-ray) and few-group (22-neutron/10-gamma-ray) structures are tailored to the sodium and iron resonances, windows, and capture gamma-ray spectra. The best weighting functions are shown to be fine-group fluxes selected from a few key locations in the geometry. These group structures and weighting functions, relative to existing group structures and conventional weighting functions, improve the accuracy of the computed 61-neutron-group Bonner ball responses by up to one hundred percent and of the computed 22-neutron-group results by up to six hundred percent.
1987-01-01
British Library Electronic Table of Contents (United Kingdom)
Summary Dietary fibres are believed to reduce subjective appetite, energy intake and body weight. However, different types of dietary fibre may affect these outcomes differently. The aim of this review was to systematically investigate the available literature on the relationship between dietary fibre types, appetite, acute and long-term energy intake, and body weight. Fibres were grouped according to chemical structure and physicochemical properties (viscosity, solubility and fermentability). Effect rates were calculated as the proportion of all fibre-control comparisons that reduced appetite (n-=-58 comparisons), acute energy intake (n-=-26), long-term energy intake (n-=-38) or body weight (n-=-66). For appetite, acute energy intake, long-term energy intake and body weight, there were cl...
2011-01-01
By using the paired comparison methodology, it was possible to establish evaluative priorities, providing criterion weights which reflected the thoughts and feelings of an advisory committee consisting of experts in the task selection process. For the U.S. Army Infantry School, the weights can be used to stress higher weighted criterion results in the task selection process. By extending the size and diversity of the advisory committee, the use of paired comparison methodology can provide an effective, reliable procedure for (1) constructing evaluative criterion weights for the task selection process and in other areas which have multiple criteria used for evaluative purposes and (2) incorporating into an evaluative design the valuable contributions of various experts and interest groups. (Author/BW)
1981-04-01
Body weight is a strong predictor of postural stability
British Library Electronic Table of Contents (United Kingdom)
Proper balance control is a key aspect of acitivities of daily living. The aim of this study was to determine the contribution of body weight to predict balance stability. The balance stability of 59 male subjects with BMI ranging from 17.4 to 63.8kg/m2 was assessed using a force platform. The subjects were tested with and without vision. A stepwise multiple regression analysis was used to determine the independent effect of body weight, age, body height and foot length on balance stability (i.e., mean speed of the center of foot pressure). With vision, the stepwise multiple regression revealed that body weight accounted for 52% of the variance of balance stability. The addition of age contributed a further 3% to explain balance control. Without vision, body weight accounted for 54% of the...
2007-01-01
Studies on sup(99m)Tc-pertechnetate from the MEK solvent extraction generator
International Nuclear Information System (INIS)
Analysis by gas chromatography-mass spectrometry and high performance liquid chromatography has revealed organic residues in sup(99m)Tc-pertechnetate obtained from "9"9Mo-molybdate by extraction, using the organic solvent methylethylketone (MEK). The organic residues have been identified as either (i) low molecular weight carbonyl compounds such as formaldehyde, acetaldehyde and acetone, presumably caused by the effects of #gamma#-radiation on MEK, or (ii) condensation products resulting from the action of strong alkali on MEK during the extraction process. The quantities of organic residues varied from batch to batch of extracted pertechnetate; up to 40 #mu# mL"-"1 was found. When these compounds were tested, in rats, by addition to a pyrophosphate bone-seeking radiopharmaceutical, the tissue distribution was not significantly different from that in the control, which contained no added compound. Assay for "9"9Tc in MEK-derived pertechnetate ...
Effects of antioxidants on lipid peroxide formation in irradiated synthetic diets
International Nuclear Information System (INIS)
The effects of the antioxidants, vitamin E, propyl gallate, 2-t-butyl-4-methoxy phenol (BHA), 2,6-di-t-butyl-4-methoxy phenol (BHT), nor-dihydroguaiaretic acid (NDGA) and diphenyl-p-phenylene diamine (DPPD) in concentrations ranging between 0.001 per cent and 0.1 per cent have been tested on lipid peroxide formation in synthetic diet mixtures containing herring oil (10 per cent) mixed with starch (90 per cent) irradiated with #gamma#-ray doses of 100 to 2000 krad. On a weight basis NDGA, DPPD, BHA and BHT were most effective and vitamin E and propyl gallate were least effective. An antioxidant concentration of 0.01 per cent normally protected against peroxide formation after a dose of 500 krad but if the dose was increased to 1000 or 2000 krad, much higher doses of antioxidant, up to 0.1 per cent, were required to give protection. Antioxidants prevented peroxide developing during post-irradiation storage even when added after irradiation. Antioxidants were ...
Design and integration of a solar AMTEC power system with an advanced global positioning satellite
Energy Technology Data Exchange (ETDEWEB)
A 1,200-W solar AMTEC (alkali metal thermal-to-electric conversion) power system concept was developed and integrated with an advanced global positioning system (GPS) satellite. The critical integration issues for the SAMTEC with the GPS subsystems included (1) packaging within the Delta 2 launch vehicle envelope, (2) deployment and start-up operations for the SAMTEC, (3) SAMTEC operation during all mission phases, (4) satellite field of view restrictions with satellite operations, and (5) effect of the SAMTEC requirements on other satellite subsystems. The SAMTEC power system was compared with a conventional planar solar array/battery power system to assess the differences in system weight, size, and operations. Features of the design include the use of an advanced multitube, vapor anode AMTEC cell design with 24% conversion efficiency, and a direct solar insolation receiver design with integral LiF salt canisters for energy storage to generate power during the ...
1996-12-31
Convolution/superposition using the Monte Carlo method
International Nuclear Information System (INIS)
The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator tongue-and-groove. The use of explicit ...
2003-07-21
Biosorption of Americium-242 by saccharomyces cerevisiae: preliminary evaluation and mechanism
International Nuclear Information System (INIS)
As an important radioisotope in nuclear industry and other fields, americium-241 is one of the most serious contamination concerns duo to its high radiation toxicity and long half-life. In this experiment, the biosorption of "2"4"1Am from solution by a fungus, Saccharomyces cerevisiae (S. cerevisiae), and the effects of various experimental conditions on the biosorption and the mechanism were explored. The preliminary results showed that S. cerevisiae is a very efficient biosorbent. An average of more than 99% of the total "2"4"1Am could be removed by S. cerevisiae of 2.1g/L (dry weight) from "2"4"1Am solutions of 2.22MBq/L -555 MBq/L (Co). The adsorption equilibrium was achieved within 1 hour and the optimum pH ranged 1-3. The culture times of more than 16 hours were suitable and the efficient adsorption of 241Am by the S. cerevisiae could be noted. The biosorption of 241Am by the decomposed cell wall, protoplasm or cell membrane of S. ...
Energy Technology Data Exchange (ETDEWEB)
A representative National Survey to evaluate the exposure to natural sources of ionizing radiation in dwellings was conducted in all the 21 Italian Regions from 1989 to 1998, and the complete results are reported in this paper. Radon concentration was measured for two consecutive 6-month periods (generally covering the spring-summer and autumn-winter seasons) in one room, usually the main bedroom, of each surveyed dwelling. Validated radon concentration measurements were obtained for a total of 5631 dwellings, distributed in 232 towns (all the 50 towns with more than 100,000 inhabitants and 182 randomly sampled smaller towns). The national average, weighted by the population of each Region, of the annual radon concentration is 70Bqm{sup -3}, the geometric mean is 52Bqm{sup -3}, and the geometric standard deviation is 2.1. The fraction of dwellings with a radon concentration exceeding the reference levels of 150, 200, 400, and 600Bqm{sup -3} are ...
2005-11-15
Individual differences and weight bias: Do people with an anti-fat bias have a pro-thin bias?
While levels of weight bias vary among individuals, it is not clear why one person possesses stronger anti-fat attitudes than another person. This investigation examined whether individual differences commonly associated with greater anti-fat bias are also associated with a greater preference for thinness among people of varying levels of weight. Young adults (62% women; 84% Caucasian) recruited from psychology classes (N=308) rated four male and female figures with approximate BMIs of 18.5, 25, 30, and 40, on measures of dislike and personality characteristics and completed measures assessing weight controllability, attitudes toward the obese, and perceptual reliance. Greater negative attitudes, weight controllability beliefs, and perceptual reliance were positively associated with greater dislike and negative personality attributes among obese/severely obese figures, but inversely related among low ...
2010-01-20
An Optimized Weighted Association Rule Mining On Dynamic Content
Association rule mining aims to explore large transaction databases for association rules. Classical Association Rule Mining (ARM) model assumes that all items have the same significance without taking their weight into account. It also ignores the difference between the transactions and importance of each and every itemsets. But, the Weighted Association Rule Mining (WARM) does not work on databases with only binary attributes. It makes use of the importance of each itemset and transaction. WARM requires each item to be given weight to reflect their importance to the user. The weights may correspond to special promotions on some products, or the profitability of different items. This research work first focused on a weight assignment based on a directed graph where nodes denote items and links represent association rules. A generalized version of HITS is applied to the graph to ...
2010-01-01
THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999
Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.
Application of gamma radiation
International Nuclear Information System (INIS)
Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).
1985-12-10
International Nuclear Information System (INIS)
... chemical radiation effects decomposition extraction columns gamma radiation
1972-01-01
International Nuclear Information System (INIS)
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...
Radiation Therapy in Treating Patients With Prostate Cancer
Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility
2011-09-13
Measurement of fast fluctuations of radiation intensity in pulsed charged particle accelerators
International Nuclear Information System (INIS)
... beam monitoring betatrons delay circuits errors fluctuations gamma radiation
biotechnological studies on the effect of gamma rays on peanut
International Nuclear Information System (INIS)
local peanut cultivars Giza 4 and Giza 5 were exposed to different doses ( 50,100,150,200,250 and 300 Gy)to Co "6"0 gamma ray source . all irradiated materials were cultivated to give the M_1 and M_2 generation , then high yielding mutants were selected from the M_2 generation and cultivated separately to give the M_3 generation. some yield component traits were measured for the three generations (M_1,M_2 and M_3) and M_3 families.variations observed in these traits were attributed to genetic factors. the M_3 selected mutants were artificially infected by aspergillus flavus L spores (aflatoxins-B1 and B2 groups-producer strain). aflatoxin concentrations were estimated and the analysis showed that aflatoxin concentrations in seeds of the M_3 selected mutants from cultivar Giza 4 were higher than those in seeds of the M3 mutants selected from cultivar Giza 5. however, the concentration of aflatoxin increased when the yield ( weight of seeds per ...
2007-01-01
THE STATE OF STAR FORMATION AND THE INTERGALACTIC MEDIUM AT z #approx# 6
International Nuclear Information System (INIS)
In the context of stellar reionization in the standard cold dark matter model, we analyze observations at z #approx# 6 and are able to draw three significant conclusions with respect to star formation and the state of the intergalactic medium (IGM) at z #approx# 6. (1) An initial stellar mass function (IMF) more efficient, by a factor of 10-20, in producing ionizing photons than the standard Salpeter IMF is required at z #approx# 6. This may be achieved by having either (a) a metal-enriched IMF with a lower mass cutoff of #>=#30 M_s_u_n or (b) 2%-4% of stellar mass being Population III massive metal-free stars at z #approx# 6. While there is no compelling physical reason or observational evidence to support (a), (b) could plausibly be fulfilled by continued existence of some pockets of uncontaminated, metal-free gas for star formation. (2) The volume-weighted neutral fraction of the IGM of
2010-12-10
Energy Technology Data Exchange (ETDEWEB)
In transfusion-dependent {beta}-thalassemia major, increased iron deposition in the pituitary gland has a cytotoxic effect leading mainly to hypogonadotropic hypogonadism. Our purpose was to assess in these patients the height of the pituitary gland and to evaluate whether it represents a marker of pituitary gland function. In 29 patients with {beta}-thalassemia major and 35 age- and gender-matched controls the pituitary gland height was evaluated in a midline sagittal scan using a spin echo T1-weighted (500/20 TR/TE) sequence. In all patients, an extensive endocrine evaluation was performed, including measurements of spontaneous and stimulated levels of gonadotropins, thyroid hormones, growth hormone, insulin-like growth factor, and adrenal hormones. The pituitary gland height was lower in thalassemic patients with hypogonadotropic hypogonadism (n=15) (mean 3.48; SD 0.46) than in the age- and gender-matched controls (mean 6.29; SD 0.77), ...
2001-12-01
Natural and anthropogenic "1"4C in the UK coastal marine environment
International Nuclear Information System (INIS)
Prior to this study, almost no up-to-date information was available on the 'background' level of "1"4C present in the water and biota of the UK coastal marine environment. The weighted mean "1"4C activity derived from the lowest activities of dissolved inorganic carbon (DIC) and biota for sites which are remote from potential sources is 247#centre dot#6#+-#1#centre dot#0 Bq kg"-"1 carbon. This is proposed as the best estimate of the natural/weapons testing 'background' for 1995 and should be subtracted from the activity derived for any sample to establish the excess due to UK anthropogenic inputs. "1"4C activities in the DIC component of seawater and a range of marine biota are significantly enhanced above the expected 'background' value in the environment around the British Nuclear Fuels plc reprocessing plant at Sellafield, Cumbria, NW England and Amersham International plc, Cardiff, Wales. The enrichments around Sellafield are largely confined to the NE Irish ...
1997-07-01
High molecular weight DNA from pleroceroid larvae of the tapeworm Spirometra mansonoides was purified from isolated nuclei by conventional techniques. The DNA so isolated has a melting temperature (Tm) of 87 degrees C and a guanine plus cytosine (G/C) content of 44%. 5-Methyl cytosine could not be detected in plerocercoid DNA by HPLC analysis of DNA hydrolysates, by radiolabeling 5'-termini of MspI digests with polynucleotide kinase, or by comparing restriction patterns generated by MspI and HpaII. Renaturation kinetics demonstrated that the genome of S. mansonoides contains repetitive as well as single copy sequences and has a genome size estimated at approx. 1.6 X 10(9) bp. Hybridization was carried out between plerocercoid DNA and cDNAs for human beta-actin, alpha-tubulin and growth hormone (hGH). Rationale for this analysis was based on known homologies among actin and tubulin genes in numerous species and on apparent similarities between hGH and a plerocercoid ...
1990-06-21
Energy Technology Data Exchange (ETDEWEB)
The heat transfer augmentation effect by the unsteady heat conduction between the particles and heat transfer surface is one of the main factors, causing the heat transfer augmentation around the stagnation point in the gas-solid two-phase impinging jet flow. By separating and evaluating that effect, material influence on it was studied of particles and heat transfer surface, together with change by the jet flow condition. That effect enlarged with enlarging in heat capacity, multiplied by the heat conduction coefficient, of both the particles and heat transfer surface, and if both of them were constant in material combination, was dominated by the contact frequency of particles per unit time. Therefore in case of lading solid particles, equal in weight, that effect enlarges with diminishing in particle diameter. Such a heat transfer augmentation mechanism model is universally applicable to the data by Yoshida et al., using comparatively large ...
1991-05-25
Materials for power sources to meet military requirements
Energy Technology Data Exchange (ETDEWEB)
Power source requirements for the military were presented to provide guidelines for research and development planning. Power sources that contain a high amount of energy and are small, light and durable are a common request from military users. Safety, reliability and low temperature performance are also important factors in the selection of power sources, as are cost and energy efficiency. Issues concerning advanced batteries were reviewed with reference to high energy density cathode materials. Various thermoelectric and renewable energy materials were discussed, with reference to recovery and conversion of waste heat. It was suggested that photovoltaic devices could help revolutionize military logistics by modifying energy re-supply requirements. Solid Oxide Fuel Cells (SOFC) were considered in relation to the high price of the ceramic materials required for operation. It was noted that the development of SOFC anodes capable of generating hydrogen from liquid ...
2005-07-01
Le leucodistrofie: aspetti clinici e quadri con Tomografia Computerizzata e con Risonanza Magnetica
International Nuclear Information System (INIS)
Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies suggested for the mild forms of these ...
1991-01-01
International Nuclear Information System (INIS)
The status of Monte Carlo system for the simulation of Bremsstrahlung in arbitrary decays and for the decay itself of #tau# -lepton is reviewed. During the last #tau# -lepton conference in 2010 several developments of the last two years have been presented: (i) For the TAUOLA Monte Carlo generator of #tau# -lepton decays, automated and simultaneous use of many versions of form-factors for the calculation of optional weights for fits was developed and checked to work in Belle and BaBar software environment. On-going work on alternative parameterizations of hadronic decays is presented too. (ii) The TAUOLA universal interface based on HepMC (the C++ event record) is now public. A similar interface for PHOTOS is now also public. (iii) Extension of PHOTOS Monte Carlo for QED Bremsstrahlung in decays featuring kernels based on complete first order matrix element are gradually becoming widely available thanks to properties of the new, HepMC based ...
2011-07-01
The insulin signaling pathway, involving protein kinase B (PKB) and mitogen-activated protein kinase (MAPK), mediates the biological response to insulin and several growth factors and cytokines. To investigate the correlation between glucose transporter (Glut) biosynthesis and the insulin signaling pathway activated by novel compounds of Liriope platyphylla (LP9M80-H), alterations in Glut and key protein expression in the insulin signaling pathway were analyzed in the liver and brain of ICR mice treated with LP9M80-H. An in vitro assay showed that the highest level of insulin concentration was observed in the LP9M80-H-treated group, followed by the LP-H, LP-M, LP-E, and LP9M80-C-treated groups. Therefore, LP9M80-H was selected for use in studying the detailed mechanism of the insulin signaling pathway in animal systems. In an in vivo experiment, LP9M80-H induced a significant increase in glucose levels and a decrease of insulin concentration in the blood of mice, ...
2010-12-14
Development of an assay for a biomarker of pregnancy and early fetal loss
Energy Technology Data Exchange (ETDEWEB)
Human chorionic gonadotropin (hCG) is a glycoprotein hormone, secreted by the syncytiotrophoblast cells of the fertilized ovum, that enters the maternal circulation at the time of endometrial implantation. It is composed of two nonidentical subunits; ..cap alpha.. and ..beta.., with molecular weights of 14 kD and 23 kD, respectively. Human chorionic gonadotropin binds to the same receptor as hLH and displays the same biological response, namely, to stimulate the declining function of the corpus luteum to produce progestins and estrogen late in the menstrual cycle. The differences in the structures of hCG and hLH have been exploited to develop antibodies that can measure hCG specifically in the presence of hLH. Two-site antibody binding assays have been developed, based on a surface immunological concept of hCG epitopes, that involve four distinct regions to which antibodies against hCG can bind simultaneously. Antibody cooperative effects, in conjunction with ...
1987-10-01
Energy Technology Data Exchange (ETDEWEB)
The General-Purpose Heat Source (GPHS), an improved radioisotope heat source, employs a unique thermal insulation material, carbon-bonded carbon fiber (CBCF), to protect the fuel capsule and to help achieve the highest possible specific power. The CBCF insulation is made from chopped rayon fiber about 10 ..mu..m in diameter and 250 ..mu..m long, which is carbonized and bonded with phenolic resin particles. The CBCF shapes, both tubes and plates, are formed in a multiple molding facility by vacuum molding a water slurry of the carbonized chopped-rayon fiber (54 wt %) and phenolic resin (46 wt %). The molded shapes are subsequently dried and cured. Final carbonization of the resin is at 1600/sup 0/C. Machining to close tolerances (+-0.08 mm) is accomplished by conventional tooling and fixturing. The resulting material is an excellent lightweight insulation with a nominal density of 0.2 Mg/m/sup 3/ and a thermal conductivity of 0.24 W(m.K) in vacuum at 2000/sup 0/C. Several attributes ...
1985-06-01
Energy Technology Data Exchange (ETDEWEB)
For many industrial applications, materials are desired which combine light weight, high temperature strength, and stability in corrosive environments. Among competing materials, ceramics are noteworthy candidates for such applications. The use of ceramics is often constrained, however, by brittleness; i.e., low toughness. Ceramic composites are being developed to overcome this limitation. With recent advances in ceramic fiber technology, it is possible to design a composite material based on continuous ceramic fibers embedded in a ceramic matrix. The use of ceramic composites in industrial applications will result in reduced fuel consumption, but will also prevent airborne pollution (principally NO, SO{sub x}, CO{sub 2}, and particulates), and economically benefit the end user through energy and environmental savings and increased competitiveness. Industry will also benefit through increased productivity and consumers will benefit through lower energy and ...
1994-02-01
Energy Technology Data Exchange (ETDEWEB)
There are a multitude of cost centers in the typical coal mine, and almost as many ways to calculate their individual and collective effect on the bottom line. The costs of explosives is, in some ways, very difficult to determine without consideration of drilling, loading, hauling and breaking costs. Saving a nickel in explosive costs, for example, could end up costing a dollar more in crushing expenses. Typically, mines request quotations for explosives products on a weight basis. Were the market one of pure commodities, this would give a valid comparison. However, the energy being purchased often is not considered. The cost of any explosive should be considered in light of the work it can do, not the air it displaces or the price per pound. Consider in essence, the purchase of explosive energy as you would the sale of coal, in terms of dollars per Btu. Recent new developments in explosives technology make the economic implications of blast design and explosive ...
1987-03-01
Standards and guidances for limiting ionizing radiation exposure
Energy Technology Data Exchange (ETDEWEB)
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
1992-12-31
Radiation protection in the operating room
International Nuclear Information System (INIS)
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
Possible health effects of working with VDUs.
UK PubMed Central (United Kingdom)
A summary of the effects presented here is given in the table. The designation "factor present" implies that there is knowledge (from human or animal studies, or both) of a specific factor(s) present...Full Text Available
1989-04-01
Human Factors in Network Security
... TITLE (Indlude Security Classifkcation) Human Factors in Network Security 12. ... FIELD GROUP SUBGROUP Human Factors, Network, Security 19. ...
1991-03-21
The safety issues of medical robotics
International Nuclear Information System (INIS)
In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, ...
2001-08-01
The impact of accretion disk winds on the X-ray spectrum of AGN: Part 1 - XSCORT
(abridged) The accretion disk in AGN is expected to produce strong outflows, in particular a UV-line driven wind. Despite providing a good fit to the data, current spectral models of the X-ray spectrum of AGN observed through an accretion disk wind are ad-hoc in their treatment of the properties of the wind material. In order to address these limitations we adopt a numerical computation method that links a series of radiative transfer calculations, incorporating the effect of a global velocity field in a self-consistent manner (XSCORT). We present a series of example spectra from the XSCORT code that allow us to examine the shape of AGN X-ray spectra seen through a wind, for a range of velocity and density distributions, total column densities and initial ionization parameters. These detailed spectral models clearly show considerable complexity and structure that is strongly affected by all these factors. The presence of sharp features in the ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
High energy radiation was studied as a means for destroying hazardous organic chemical wastes. Tests were conducted at bench scale with a {sup 60}Co source, and at full scale (387 l/min) with a 1.5 MV electron beam source. Bench scale tests for both benzene and phenol included 32 permutations of water quality factors. For some water qualities, as much as 99.99% of benzene or 90% of phenol were removed by 775 krads of {sup 60}Co irradiation. Full scale testing for destruction of benzene in a simulated waste-water mix showed loss of 97% of benzene following an 800 krad dose and 88% following a 500 krad dose. At these loss rates, approximately 5 Mrad of electron beam irradiation is required to reduce concentrations from 100 g/l to drinking water quality (5 {mu}g/l). Since many waste streams are also inhabited by bacterial populations which may affect filtering operations, the effect of irradiation on those populations was also studied. {sup 60}Co ...
1993-08-01
Study of e{sup +}e{sup -}{yields}pp using initial state radiation with BABAR
The e{sup +}e{sup -}{yields}pp cross section is determined over a range of pp masses, from threshold to 4.5 GeV/c{sup 2}, by studying the e{sup +}e{sup -}{yields}pp{gamma} process. The data set corresponds to an integrated luminosity of 232 fb{sup -1}, collected with the BABAR detector at the PEP-II storage ring, at an e{sup +}e{sup -} center-of-mass energy of 10.6 GeV. The mass dependence of the ratio of electric and magnetic form factors, G{sub E}/G{sub M}, is measured for pp masses below 3 GeV/c{sup 2}; its value is found to be significantly larger than 1 for masses up to 2.2 GeV/c{sup 2}. We also measure J/{psi}{yields}pp and {psi}(2S){yields}pp branching fractions and set an upper limit on Y(4260){yields}pp production and decay.
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained ...
2001-04-01
International Nuclear Information System (INIS)
When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid ...
2001-04-01
Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents
Energy Technology Data Exchange (ETDEWEB)
This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another sliding graph permits the estimation of critical solution fission yields based upon fissile material concentration, critical vessel geometry, and ...
1999-09-20
Review of Experimental Studies of $\\psi(3770)$ non-$D\\bar D$ Decays
We review the progress on experimental studies of the non-$D\\bar D$ decays of the $\\psi(3770)$ resonance. With the world average of the observed cross sections for $D\\bar D$ production measured at 3.773 GeV by the MARK-I, MARK-II, BES and CLEO Collaborations, combined together with the cross section for $\\psi(3770)$ production at its peak as well as initial state radiative correction factor, we find that the non-$D\\bar D$ branching fraction of $\\psi(3770)$ decays is $B[\\psi(3770)\\to {\\rm non}-D\\bar D]=(19.8\\pm 1.8 \\pm 5.6)%$, which is consistent within error with $B[\\psi(3770)\\to {\\rm non}-D\\bar D]=(14.7\\pm 3.2)%$ measured previously by the BES Collaboration. In addition, a global amplitude analysis of the cross sections for $e^+e^- \\to {\\rm LH}$ (LH= light hadron) measured by the CLEO Collaboration shows that the light hadron branching fraction of $\\psi(3770)$ decays can be as large as about 11%. Combing the totally ...
2010-01-01
Process development for remote-handled mixed-waste treatment
Energy Technology Data Exchange (ETDEWEB)
The Oak Ridge National Laboratory (ORNL) is developing a treatment process for remote-handled (RH) liquid transuranic mixed waste governed by the concept of minimizing the volume of waste requiring disposal. This task is to be accomplished by decontaminating the bulk components so the process effluent can be disposed with less risk and expense. Practical processes have been demonstrated on the laboratory scale for removing cesium 137 and strontium 90 isotopes from the waste, generating a concentrated waste volume, and rendering the bulk of the waste nearly radiation free for downstream processing. The process is projected to give decontamination factors of 10{sup 4} for cesium and 10{sup 3} for strontium. Because of the extent of decontamination, downstream processing will be contact handled. The transuranic, radioactive fraction of the mixed waste stream will be solidified using a thin-film evaporator and/or microwave solidification system. ...
1990-01-01
Physics of electron beam therapy
International Nuclear Information System (INIS)
A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...
Ozone production at the National Synchrotron Light Source
International Nuclear Information System (INIS)
Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10"1"2 and 10"1"5 eV . cm"-"3 . sec"-"1. The measured ozone half-life was 37 +- 2 min. The measured G-value was 2.69 +- 0.14 mol/100 eV and the ozone destruction factor k was less than 7 x 10"-"1"9 cm"3 . eV"-"1. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppM ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene aspects of operation and possible control ...
1998-09-20
International Nuclear Information System (INIS)
Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10/sup 12/ and 10/sup 15/ eV/sup . /cm/sup -3 . /sec/sup -1/. The measured ozone half-life was 37+-2 min. The measured G-value was 2.69+-0.14 mol/100 eV and the ozone destruction factor k was less than 5 x 10/sup -19/cm/sup 3//eV. The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppm ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene aspects of operation and ...
Energy Technology Data Exchange (ETDEWEB)
A competitive repopulation assay utilizing chromosome markers was used to assay the reconstituting potential of hematopoietic populations. The test populations consisted of tibial murine marrow locally irradiated with doses ranging from 1.5 Gy to 8.5 Gy and of marrow generated from either murine splenic or marrow stem cells. The purpose of this assay was to assess the innate proliferative potential and microenvironmental influences on the ability to repopulate. Regardless of origin, spleen repopulating ability consistently agreed with spleen colony-forming unit (CFU-s) content. Doses of radiation from 5 Gy to 8.5 Gy diminished, by a factor of 2, the ability to repopulate marrow despite maintenance of CFU-s levels. Marrow generated from splenic stem cells had one-fifth the repopulating ability of marrow derived from marrow stem cells, even though CFU-s levels were equivalent. The results imply that the splenic environment can only maintain stem ...
1988-03-01
New short-range electromagnetic current in the deuteron
International Nuclear Information System (INIS)
A new model for short-range isoscalar current in the deuteron and NN system is developed and tested on a variety of isoscalar magnetic observables such as the deuteron magnetic moment, magnetic form factor, and the circular polarization of photons at n"#->#p radiative capture at thermal neutron energies. The model for electromagnetic two-nucleon current proposed in the paper is based on generation of an intermediate dibaryon in the short-range NN interaction. This intermediate dibaryon, in turn, is treated within the new model for intermediate and short-range NN interaction recently proposed by the present authors. The transition current model developed here satisfies the current conservation relation by the construction. Our calculations have demonstrated that the new current model, using only one parameter (with a clear physical meaning), is able to describe, in very good agreement with the experimental data, three basic deuteron ...
2007-02-01
International Nuclear Information System (INIS)
Among in uterus exposed A-bomb survivors, fetal week is the most important factor to clarify the effects of A-bomb radiation on developmental process of the fetal brain. The study population of in utero exposed A-bomb survivors has first been established in 1953 in Hiroshima and in 1955 in Nagasaki. According to the estimated DS86 uterus absorption doses, fetal absorption doses obtained from the uterus doses, and intelligence quotient. Various studies on brain damage, including microcephaly, have been undertaken among in uterus exposed A-bomb survivors. Brain development has been shown to be affected during the fetal weeks 8-15 and 16-25. A review of the literature has revealed that 80% of the children with mental retardation and 15 of 18 cases of microcephaly (83%) were exposed in utero during the fetal week 8-15. Among children exposed at the fetal weeks 8-15 and 16-25, average learning was significantly decreased. The incidence of spasm was ...
Large-p heavy-quark production in two-photon collisions
International Nuclear Information System (INIS)
The next-to-leading-order (NLO) cross section for the production of heavy quarks at large transverse momenta #gamma##gamma# collision is calculated with perturbative fragmentation functions (PFF). This approach allows for a resummation of terms #propor to# #alpha#_sln(p"2/m"2) which arise in NLO from collinear emission of gluons by a heavy quark at large p or from almost collinear branching of photons or gluons into heavy-quark pairs. It is presented single-inclusive distributions in p and rapidity including direct and resolved photons for #gamma##gamma# production of heavy quarks at e"+e"-colliders and at high-energy #gamma##gamma# colliders. The results are compared with fixed- order calculation for m finite including QDC radiative corrections. The two approaches differ in the definitions and relative contributions of the direct and resolved terms, but essentially agree in their sum. The resummation of the #alpha#_sln(p"2/m"2) terms in the PFF approach leads to a ...
2002-05-01
Interaction of x-rays and food pyrolysis products in producing oncogenic transformation in vitro
International Nuclear Information System (INIS)
In recent years it has become evident from epidemiological and experimental data that a large number of environmental factors, including diet, play a role in modifying the incidence of cancer. Cell culture systems in which oncogenic transformation serves as an end point are powerful tools for evaluating these questions. Using such systems it has been shown recently that pyrolysis products from charred surfaces of broiled meat and fish can transform hamster embryo cells in vitro as well as produce tumors in the animal. Our studies in vitro have demonstrated the oncogenic potential of ionizing radiation in both hamster and human cells and have established in hamster cells the dose response relationship at doses ranging from 1 to 600 rad for x-rays and 0.1 to 150 rad for neutrons. The present work was aimed at evaluating whether there exists a cocarcinogenic interaction between a pyrolysis product and x-rays in their ability to transform hamster ...
1981-07-01
Induction of mutation in Trichoderma viride for conversion of natural cellulose into glucose
Energy Technology Data Exchange (ETDEWEB)
The production of cellulolytic enzymes from fungi has been extensively studied. Several mutants of Trichoderma reesei were selected. Most of the studies were carried out on T. reesei, T. viride, T. harzianum, Penicillium funiculosum, Altemaria alternata. Aspergillus phoenicis, A. ustus, A. tamarii, A. japonicus, and A. niger. T. koningii is one of the most active producers of the so-called C, factor, which is indispensable for the rapid and extensive attack on crystal-line cellulose. However, Trichodenna is known to excrete only small amounts of {beta}-glucosidase. Therefore, Trichoderma is supplemented with {beta}-glucosidase from Aspergillus to increase the saccharification rate of cellulose to glucose as the main sugar. Induction of mutations in Trichodenna spp. rather than T. viride as a tool for the enhancement of {beta}-glucosidase activity was reported. Unfortunately, T. reesei is a poor producer of {beta}-glucosidase. On the other hand, T. harzianum M{sub ...
1991-12-31
Fractional Shapiro steps in electron interference in the presence of nonclassical microwaves
Energy Technology Data Exchange (ETDEWEB)
Electron interference in the presence of nonclassical microwaves with frequency {omega}{sub 1} and classical RF radiation with frequency {omega}{sub 2}, is studied. The relative phase factor between the two electron beams is a quantum-mechanical operator, whose expectation value with regard to the density matrix describing the nonclassical microwaves, determines the interference. It is shown that the visibility of the time-averaged intensity is a constant for all irrational values of {omega}{sub 1}/{omega}{sub 2}, and shows peaks (fractional Shapiro steps) at all rational values. These peaks can provide direct experimental evidence of the highly nonlinear processes of frequency conversion from {ital N} photons with frequency {omega}{sub 1}, to {ital M} photons with frequency {omega}{sub 2}. Results for various types of nonclassical microwaves (e.g., coherent states, squeezed states, number eigenstates, etc.) are derived and a comparison with ...
1996-11-01
Donut-shaped high-dose configuration for proton beam radiation therapy
Energy Technology Data Exchange (ETDEWEB)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable ...
2005-01-01
Donut-shaped high-dose configuration for proton beam radiation therapy
International Nuclear Information System (INIS)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable to ...
2005-01-01
Design modifications in 540 MWe and its impact on the dose rates
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full power, through this paper attempt is ...
2005-11-23
Cytotoxic effects of WR-2721 on mouse testicular cells
Energy Technology Data Exchange (ETDEWEB)
WR-2721 (S-2-(3-aminopropylamino)ethylphosphorothioic acid) has been demonstrated to be cytotoxic to stem spermatogonia in the mouse. Five and 10 injections of 300 mg/kg killed sufficient numbers of stem cells to reduce sperm production 56 days after treatment by 16 and 43%, respectively. Single injections of 300 or 400 mg/kg of WR-2721 given 15 min after irradiation produced negligible toxicity to stem cells as measured by counts of repopulated tubules; 600 mg/kg reduced stem cell survival by 47%. Four daily injections of 300 mg/kg given 4, 3, 2, and 1 days prior to irradiation reduced stem cell survival by about 60%. The cytotoxic effects of WR-2721 on testicular stem cells at least partially explains the reduced protection factors observed in the testis with low doses of radiation and during fractionated treatments involving multiple injections of drug.
1984-09-01
Can photo-ionization explain the decreasing fraction of X-ray obscured AGN with luminosity?
Chandra and XMM surveys show that the fraction of obscured AGN decreases rapidly with increasing luminosity. Although this is usually explained by assuming that the covering factor of the central engine is much smaller at luminous QSOs, the exact origin of this effect remains unknown. We perform toy simulations to test whether photo-ionisation of the obscuring screen in the presence of a strong radiation field can reproduce this effect. In particular, we create X-ray spectral simulations using a warm absorber model assuming a range of input column densities and ionization parameters. We fit instead the simulated spectra with a simple cold absorption power-law model that is the standard practice in X-ray surveys. We find that the fraction of absorbed AGN should fall with luminosity as $L^{-0.16\\pm0.03}$ in rough agreement with the observations. Furthermore, this apparent decrease in the obscuring material is consistent with the dependence of ...
2008-01-01
Assessment of dose-time-effect surfaces for somatic late effects after low dose irradiation
International Nuclear Information System (INIS)
Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by pure chance than by the dose dependency ...
1988-04-01
Actinides in liquid waste formed in the regeneration of nuclear fuel from a VVER-1000 reactor
International Nuclear Information System (INIS)
In the radiochemical reprocessing of spent fuel from nuclear reactors, a considerable amount of liquid, solid, and gaseous waste is formed; this waste is potentially dangerous to humans and requires the development of special and complex technological techniques for its localization and reliable long-term storage. The most hazardous are liquid wastes of high specific activity - water-tailings solutions obtained in the first cycle of extraction after the removal of uranium and plutonium. These solutions contain more than 99.9% of all the other transuranic elements - isotopes of neptunium, americium, and curium. Where necessary, some fission products and actinides may be removed from wastes of high specific activity for subsequent use. The quantity, composition, and activity of these wastes varies within broad limits, depending on the type and power of the reactor, the initial nuclide composition of the fuel, and its specific energy yield, the regeneration technology, and other ...
Survey of Radiation Protection Education and Training in Finland in 2003
Energy Technology Data Exchange (ETDEWEB)
The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...
2004-07-01
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
Energy Technology Data Exchange (ETDEWEB)
Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single cells irradiated at very low radiation doses (1-100 mGy) ...
2007-09-15
International Nuclear Information System (INIS)
The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in ...
Reference neutron transport calculation note for Korea nuclear power plants with 3-loop PWR reactors
Energy Technology Data Exchange (ETDEWEB)
Reactor pressure vessel (RPV) steels are subjected to neutron irradiation at a temperature of about 290 deg C. This radiation exposure alters the mechanical properties, leading to a shift of the brittle-to-ductile transition temperature toward higher temperatures and to a diminution of the rupture energy as determined by Charpy V-notch tests. This radiation embrittlement is one of the important aging factors of nuclear power plants. U.S. NRC recommended the basic requirements for the determination of the pressure vessel fluence by regulatory guide DG-1025 in order to reduce the uncertainty in the determination of neutron fluence calculation and measurements. The determination of the pressure vessel fluence is based on both calculations and measurements. The fluence prediction is made with a calculation and the measurements are used to qualify the calculational methodology. Because of the importance and the difficulty of ...
1997-05-01
Radiation hardening technologies facing total dose, S.E.U. and S.E.L. in spatial environment
International Nuclear Information System (INIS)
Space particles act on semiconductor devices by creating charges (electrons, holes) in the silicon and the silicon dioxide, and by creating displacement damage. These primary phenomena alter the electrical parameters of MOS and bipolar devices (threshold voltage V_t, mobility #mu#, conductivity #sigma#, current gain #beta#). The dose rate is not important in space (a few rad (Si)/h) but as the durations of space expeditions are on average from seven to twelve years, the total dose is an aggravating factor in the behaviour of the electrical parameters and also in device operation. The total dose effect from the beginning of charge creation (ionization) to the parameter shifts is reviewed. One can note that this effect is permanent because there will almost always be charge creation in space. Another important phenomenon is called the Single Event Upset (S.E.U.) and caused by the heavy ions and the protons which come from the galactic rays. The consequence of S.E.U. ...
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
International Nuclear Information System (INIS)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the interinstitutional variations were not ...
2007-06-01
ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2
International Nuclear Information System (INIS)
During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type enclosure and showed ...
Global changes and the air-sea exchange of chemicals
International Nuclear Information System (INIS)
Present and potential future changes to the global environment have important implications for marine pollution and for the air-sea exchange of both anthropogenic and natural substances. This report addresses three issues related to the potential impact of global change on the air-sea exchange of chemicals: Global change and the air-sea transfer of the nutrients nitrogen and iron. Global change and the air-sea exchange of gases. Oceanic responses to radiative and oxidative changes in the atmosphere. The deposition of atmospheric anthropogenic nitrogen has probably increased biological productivity in coastal regions along many continental margins. Atmospheric deposition of new nitrogen may also have increased productivity somewhat in mid-ocean regions. The projected future increases of nitrogen oxide emissions from Asia, Africa and South America will provide significant increases in the rate of deposition of oxidized nitrogen to the central North Pacific, the ...
1996-08-01
Elemental transfer from Chinese soil via the diet to the whole human body
International Nuclear Information System (INIS)
Based on results from recent studies of elemental dietary intake and organ or tissue content for adult Chinese men, quoted nationwide elemental concentrations in Chinese soil and newly published national average consumption of dietary foods, values of both transfer coefficients and discrimination factor (DF) for transfer from soil via the diet to both critical organs and the whole body have been calculated for important elements in radiation protection, including alkaline earths, alkali metals, rare earths and other related elements. These calculations have used both the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) model and the DF method. In the UNSCEAR model, the basic parameters used to describe the transport of radionuclides are the transfer coefficients P_i_j, which describe the relationship of concentrations or other amounts between compartment i and the following compartment j, ...
2008-12-01
International Nuclear Information System (INIS)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the measurements for the ...
2009-10-01
International Nuclear Information System (INIS)
The results of investigation into a new series of Z-even nuclei - precursors of delayed protons (PDP) -"6"5Ge, "8"9Se, "9"3Kr, "8"1Zr, and "8"5Mo are presented. PDP were obtained by irradiation of targets in the following reactions: Zn(He, 2n) "6"5Ge, 22 MeV; "4"0Ca("3"2S, 2 pn) "1"9Se, 100 MeV; "6"0Ni ("1"60, 3 n), "7"3Kr, 75 MeV; "5"2Cr ("3"2S, 3n)"8"1Zr, 110 MeV; "5"6Fe("3"2S, 3n)"8"5Mo, 120 MeV. The targets (self-sustaining foils of thickness approximately 1.2 mg/cm"2) were placed at an angle of 15 deg to the direction of the ion beam. Upon irradiation targets were moved downwards into a measuring position. The spectra of protons, X and gamma-rays, and also the spectra of p - x, p-#gamma#, x - #gamma# coincidences accompanying the decay of "6"5Ge, "6"9Se,"7"3Kr and "8"1Zr, and "8"5Mo were measured. The measured half-lives are equal, to 31.5+-1.9, 27.3+-0.5, 28.5+-1.1, 6.3+-0.5, and 5.6 +-0.9 s respectively. The experimental spectra are compared with the calculated ones. The proton ...
International Nuclear Information System (INIS)
Large-scale decommissioning of Russian nuclear-powered submarines (NPS) and their utilization prospects gave rise to numerous complicated scientific and technical, as well as economic, problems. Problems of handling of radioactive equipment from the reactor compartments (RC) are among the vital ones, arousing a growing concern with the public. Without solution of the problems the processes of NPS utilization can not be considered completed. It involves potential hazard, for the environment both from NPS being paid up (temporal on-float storage) with unloaded spent nuclear fuel (SNF), and RC, cut from submarine hull, containing highly radioactive equipment and materials but no SNF. Diverse variations of the concept of reactor compartment handling of NPS subject to, utilization are possible, but, in principle, there are essentially two variants: (1) RC utilization directly in the course of NPS utilization, envisaging removal of radioactive equipment from the reactor compartment and its ...
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by ...
1990-11-01
MRI with pathogenic correlation of small renal cell carcinoma
Energy Technology Data Exchange (ETDEWEB)
MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell carcinoma which ...
1999-11-01
International Nuclear Information System (INIS)
The fundamental optical absorption of ion crystals characterizes the creation of different free low energetic electronic excitation (the excitons and electron-hole pairs), but their straight registration is not possible because of incommensurable big absorption factor of alkali halide monocrystals. So to registration the spectrums of alkali halide monocrystal very fine layers are necessary. We have received fine films of Nal and KCl in system of KCl-Nal-KCl, KCl-KI-KCl on the base of universal vacuum post VUP-4, VUP-5 by thermal evaporation. A unique spectral unit has been created For this on the basic the SDL-2 complex. Complex consists of radiator, systems of condensers, monochromators MDR-12 and MDR-23, receivers of radiation, controller by unit. Connect and control of monochromators by means of IBM-compatible computer has been created. Kinematics schemes of monochromators provide consequent removing on output slot of ...
UK PubMed Central (United Kingdom)
Dysregulation of the alternative pathway of complement activation, caused by mutations or polymorphisms in the genes encoding factor H, membrane co-factor protein, factor I or factor B, is associated...Full Text Available
2009-01-01
UK PubMed Central (United Kingdom)
In the CNS, there are widespread and diverse interactions between growth factors and estrogen. Here we examine the interactions of estrogen and brain-derived neurotrophic factor (BDNF), two...Full Text Available
2006-12-01
Disulfide Bonds and the Quaternary Structure of Factor VIII/von Willebrand Factor
UK PubMed Central (United Kingdom)
Human Factor VIII/von Willebrand factor, purified by calcium citrate-cellulose chromatography and 4% agarose gel filtration was subjected to sodium dodecyl sulfate gel electrophoresis on gels containing...Full Text Available
1978-09-01
Energy Technology Data Exchange (ETDEWEB)
The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This 2001 annual report covers the fifth year of sampling of this multi-year study. In 2001 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon rivers. The Snake River was sampled between Lower Granite Dam (rkm 174) and the mouth of the Salmon River (rkm 303), and the Salmon River was sampled from its mouth upstream to Hammer Creek (rkm 84). A total of 45,907 hours of setline effort and 186 hours of hook-and-line effort was employed in 2001. A total of 390 white sturgeon were captured and tagged in the Snake River and 12 in the Salmon River. Since 1997, 36.1 percent of the tagged white sturgeon have been recaptured. ...
2003-03-01
Energy Technology Data Exchange (ETDEWEB)
The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This 2000 annual report covers the fourth year of sampling of this multi-year study. In 2000 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon rivers. The Snake River was sampled between Lower Granite Dam (rkm 174) and the mouth of the Salmon River (rkm 303), and the Salmon River was sampled from its mouth upstream to Hammer Creek (rkm 84). A total of 53,277 hours of setline effort and 630 hours of hook-and-line effort was employed in 2000. A total of 538 white sturgeon were captured and tagged in the Snake River and 25 in the Salmon River. Since 1997, 32.8 percent of the tagged white sturgeon have been ...
2003-03-01
Energy Technology Data Exchange (ETDEWEB)
The specific research goal of this project is to identify means to restore and rebuild the Snake River white sturgeon (Acipenser transmontanus) population to support a sustainable annual subsistence harvest equivalent to 5 kg/ha/yr (CBFWA 1997). Based on data collected, a white sturgeon adaptive management plan will be developed. This report presents a summary of results from the 1997-2002 Phase II data collection and represents the end of phase II. From 1997 to 2001 white sturgeon were captured, marked, and population data were collected in the Snake and Salmon. A total of 1,785 white sturgeon were captured and tagged in the Snake River and 77 in the Salmon River. Since 1997, 25.8 percent of the tagged white sturgeon have been recaptured. Relative density of white sturgeon was highest in the free-flowing segment of the Snake River, with reduced densities of fish in Lower Granite Reservoir, and low densities the Salmon River. Differences were detected in the length frequency ...
2004-02-01
International Nuclear Information System (INIS)
The 177 underground storage tanks at the DOE's Hanford Site contain an estimated 180 million tons of high-level radioactive wastes. It is desirable to remove and concentrate the highly radioactive fraction of the tank wastes for vitrification. Resorcinol-formaldehyde (R-F) resin, an organic ion-exchange resin with high selectivity and capacity for the cesium ion, which is a candidate ion-exchange material for use in remediation of tank wastes. The report includes information on the structure/function analysis of R-F resin and the synthetic factors that affect performance of the resin. CS-100, a commercially available phenol-formaldehyde (P-F) resin, and currently the baseline ion-exchanger for removal of cesium ion at Hanford, is compared with the R-F resin. The primary structural unit of the R-F resin was determined to consist of a 1,2,3,4-tetrasubstituted resorcinol ring unit while CS-100, was composed mainly of a 1,2,4-trisubstituted ring. CS-100 shows the ...
2004-09-10
Energy Technology Data Exchange (ETDEWEB)
The performance of PAN-based composite absorbers was evaluated in dynamic experiments at flow rates ranging from 25--100 bed volumes (BV) per hour. Composite absorbers with active components of ammonium molybdophosphate (AMP) PAN and K-Co ferrocyanide (KCoFC) PAN were used for separating Cs from a 1 M HNO{sub 3} + 1 M NaNO{sub 3} + 2 {times} 10{sup {minus}5} M CsCl acidic simulant solution. KCoFC-PAN and two other FC-based composite absorbers were tested for separating Cs from alkaline simulant solutions containing 0.01 M to 1 M NaOH and 1 M NaNO{sub 3} + x {times} 10{sup {minus}4} M CsCl. The efficiency of the Cs sorption on the AMP-PAN absorber from acidic simulant solutions was negatively influenced by the dissolution of the AMP active component. At flow rates of 50 BV/hr, the decontamination factor of about 10{sup 3} could be maintained for treatment of 380 BV of the feed. With the KCoFC-PAN absorber, the decontamination factor of about ...
1996-05-01
International Nuclear Information System (INIS)
Purpose: To identify results and prognostic factors on long-term survival and local control following treatment of localized Ewing's sarcoma. Patients and Methods: Between 1979 and 2004, a total of 60 children and young adults with Ewing's sarcoma were treated. Patients with distant metastases at presentation (n = 6) and recurrent cases (n = 2) were excluded from this analysis. Patients were exclusively treated within ongoing national and international protocols CESS-81, CESS-86, EICESS-92, EURO-EWING-99. All patients received local irradiation with a total dose of 45-60 Gy; in addition, 41 (79%) of the patients had local surgical procedures, 27 (52%) of them with clear margins. Results: Overall survival rates at 5 and 10 years were 56% and 45%, respectively. Patients #<=# 14 years at diagnosis had overall survival rates of 66% and 61% at 5 and 10 years compared to older patients with corresponding survival rates of 47% and 31%, respectively (p = 0.05). Patients ...
2008-03-01
International Nuclear Information System (INIS)
The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and 114#+-#2 for CRC-12 and ...
2002-07-01
International Nuclear Information System (INIS)
The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by evaluating correlation ...
2002-09-21
International Nuclear Information System (INIS)
Cervix cancer is the most common female cancer in Korea. In spite of their relatively local invasive tendency, still 44% of patient will develop recurrent cancer This result suggests that more aggressive local treatment may increase the cure rate but increased complication risk also cannot be avoidable. Various institutions proposed different treatment regimen, but recommended dose were about 4500 cGy for whole pelvis and 8000 cGy at point A, even though they agreed that those doses may not be satisfactory for control of bulky disease. 96 cases of invasive cervical cancer, treated with postoperative or primary radiation therapy were analyzed to determine the complication rate and prognostic factor in our treatment regimen which is 500-1000 cGy higher than other institution. Mean follow up duration was 21 months. Symptomatic patients including mild but persistent abdominal discomfort was 46%, but only 1 patient (1%) had operative treatment ...
1989-06-01
Decontamination of the reactor coolant pump in Maanshan nuclear power plant
International Nuclear Information System (INIS)
To reduce the radiation dose that accumulated on the reactor coolant pump, decontamination work was carried out at the Maanshan Nuclear Power Plant. A four-step alkaline permanganate (AP)-CanDecon process was applied to remove the activity on the turning vane diffuser and pump impeller. The first step consisted of 8 h of AP treatment and 7 h of decontamination. It was followed by 2.5 h of AP treatment and 5 h of decontamination. An average decontamination factor of 2.9 was obtained. To understand the corrosion of the decontaminating reagents on the materials, coupons were installed in the decontamination tank. These were as-received and sensitized 304SS, alloy 600, casting stainless steel (CF-8), stellite-6, and carbon steels (A508 and A533). The exposure rates (mR h"-"1) of the carbon steels were approximately five times higher in magnitude than those of the other materials. The decontamination levels (dpm per 100 cm"2) of the A508 and A533 ...
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.