WorldWideScience
1

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

2

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

3

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

4

Radiation therapy alone versus radiation therapy and chemotherapy in the management of Hodgkin's disease.  

UK PubMed Central (United Kingdom)

Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available

1990-02-01

5

An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors  

UK PubMed Central (United Kingdom)

PurposeTo evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors.Methods...Full Text Available

2008-04-01

6

Radiation therapy in the treatment of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation ...

2007-10-01

9

Radiation Therapy in Treating Patients With Prostate Cancer  

Science.gov (United States)

Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility

2011-09-13

11

Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.

1985-07-01

14

Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer  

UK PubMed Central (United Kingdom)

BackgroundTo compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated...Full Text Available

15

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

16

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

17

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

19

Proton beam therapy for cancer in deep-seated organs  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.

1988-10-01

20

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

21

Image-based modeling of tumor shrinkage in head and neck radiation therapy1  

UK PubMed Central (United Kingdom)

Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available

2010-05-01

22

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs and Single Arc  

UK PubMed Central (United Kingdom)

PurposeA dosimetric comparison between multiple static-field intensity-modulated radiation therapy (IMRT), multi-arc intensity-modulated arc therapy (IMAT) and single-arc...Full Text Available

2010-04-01

23

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

24

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

27

Effectiveness of radiation therapy after surgery for hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Some studies suggest that giving radiation therapy after surgery for hilar cholangiocarcinoma improves the survival rate; however, many of these studies did not specify numbers of subjects or provide an impartial analysis. Thus, we evaluated the effectiveness of radiation therapy as adjuvant treatment after surgery and attempted to establish appropriate adaptation standards. We reviewed the records of 69 patients who underwent surgery for hilar cholangiocarcinoma between June 1980 and April 1998. Thirty-nine patients were treated with surgery followed by radiation therapy and 30 were treated with surgery alone. The clinicopathologic features that might have influenced prognosis were similar in the patients who received radiation therapy and those who did not. Radiation as adjuvant ...

2005-07-01

28

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

29

Radiations against tumors: a bit old-fashioned?; Rayonnements contre tumeurs: un rien demode?  

Energy Technology Data Exchange (ETDEWEB)

The proton therapy gives an irradiation adapted to the shape and the depth of tumors ( eyes, head and neck) with a millimetric, even sub millimetric precision for the ophthalmological tumors. It is equally an excellent tool for the pediatrics tumors. For numerous treatments in France the proton therapy is associated to the photons treatments (x radiation). however, others physical treatments could modulate the medical offer, such thermal therapy or treatments by ultrasonic waves. (N.C.)

2004-09-01

30

Treatment of cancer of the pancreas by intraoperative electron beam therapy: physical and biological aspects  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, ...

1989-01-01

31

Treatment of cancer of the pancreas by intraoperative electron beam therapy: physical and biological aspects  

International Nuclear Information System (INIS)

Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, ...

32

Maximum proton kinetic energy and patient-generated neutron fluence considerations in proton beam arc delivery radiation therapy  

UK PubMed Central (United Kingdom)

Several compact proton accelerator systems for use in proton therapy have recently been proposed. Of paramount importance to the development of such an accelerator system is the maximum kinetic energy...Full Text Available

2009-02-01

33

The BCNT treatment planning for the Brookhaven trials on human gliomas  

International Nuclear Information System (INIS)

Boron neutron capture therapy (BNCT) trials for human glioma (glioblastoma multiform) were initiated September 1994 at the Brookhaven National Laboratory (BNL). Patients are given p-boronophenylalanine-fructose (BPA-F) intravenously as the boron carrier followed by exposure to the epithermal-neutron beam at the Brookhaven Medical Research Reactor (BMRR). The initial phase of the study is to determine safety and toxicity of the drug and irradiation procedure. The epithermal-neutron beam was developed in a joint effort by BNL and Idaho National Engineering Laboratory (INEL) researchers. For the human trials, treatment planning and radiation dose estimation is performed using the BNCT-Rtpe and the rtt-MC computer codes developed by the INEL BNCT program. This paper discusses our initial experience using these treatment planning codes for human subjects. The basic principles of BNCT have been previously documented.

34

Local control of Ewing's sarcoma of bone with radiotherapy and combination chemotherapy  

International Nuclear Information System (INIS)

Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these more aggressive tumors.

35

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

36

Combined Modality Treatment for Prostate Cancer With Dynamic Adaptive Radiation Therapy Using Four-Dimensional Image-Guided Intensity-Modulated Radiation Therapy and Brachytherapy  

British Library Electronic Table of Contents (United Kingdom)

Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.

2009-01-01

38

Radiation therapy and Ewing's sarcoma in childhood  

International Nuclear Information System (INIS)

Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. ...

39

Medulloblastoma: Are We Overtreating?  

UK PubMed Central (United Kingdom)

Modern advances in the concept and the techniques of megavoltage radiation therapy have revolutionized the treatment of medulloblastoma. Five-year survivals of 50 to 70 percent are achieved by craniospinalaxis...Full Text Available

1985-02-01

40

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

41

Anxiety and Cancer Treatment: Response to Stressful Radiotherapy  

UK PubMed Central (United Kingdom)

Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available

1984-01-01

42

Adaptive Management of Liver Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available

2010-04-01

43

Radiation therapy in Ewing's sarcoma: an update of the CESS 86 trial  

International Nuclear Information System (INIS)

Purpose: We present an update analysis of the multiinstitutional Ewing's sarcoma study CESS 86. Methods and Materials: From January 1986 through June 1991, 177 patients with localized Ewing's sarcoma of bone, aged 25 years or less, were recruited. Chemotherapy consisted of four 9-week courses of vincristine, actinomycin D, cyclophosphamide, and adriamycin (VACA) in low-risk tumors (extremity tumors =# 100 cm"3). Local therapy was an individual decision in each patient and was either radical surgery (amputation, wide resection) or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy (45 Gy plus boost). Irradiated patients were randomized concerning the type of fractionation in either conventional fractionation (once daily 1.8-2.0 Gy, break of chemotherapy) or hyperfractionated split-course irradiation simultaneously with the VACA/VAIA chemotherapy (twice daily 1.6 Gy, break of 12 days after 22.4 Gy and 44.8 Gy, total dose and ...

1995-07-15

44

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

45

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

46

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, ...

47

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after ...

1997-05-01

48

Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer  

UK PubMed Central (United Kingdom)

PurposeWe conducted a comparative study of Clinical Target Volume (CTV) definition of pelvic lymph nodes by multiple GU radiation oncologists looking at the levels...Full Text Available

2009-06-01

49

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

50

Current Role and Future Perspectives of Magnetic Resonance Spectroscopy in Radiation Oncology for Prostate Cancer  

UK PubMed Central (United Kingdom)

Prostatic neoplasms are not uniformly distributed within the prostate volume. With recent developments in three-dimensional intensity-modulated and imageguided radiation therapy, it is possible to treat...Full Text Available

2007-06-01

51

Radiation-induced large intracranial vessel occlusive vasculopathy.  

Science.gov (United States)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port ...

1980-01-01

52

Radiation-induced large intracranial vessel occlusive vasculopathy  

Energy Technology Data Exchange (ETDEWEB)

Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port ...

1980-01-01

53

Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children  

Energy Technology Data Exchange (ETDEWEB)

During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 Gy. Irradiation session ...

1996-03-01

54

Effective radiation therapy on two cases of primary Ewing's sarcoma of the rib  

International Nuclear Information System (INIS)

Two cases of primary Ewing's sarcoma of the rib are reported, in which radiation therapy was quite effective. Case 1 was an 18-year-old female who had had an operation and radiation therapy for Ewing's sarcoma of the left 7th rib. She was referred to our hospital after a recurrent tumor was found. Radiation therapy (tumor dose 46.2 Gy) and chemotherapy were given. The tumor disappeared and there has been no relapse for 1 year and 3 months after the treatment. Case 2 was a 2-year-old-infant. Radiation therapy (tumor dose 74 Gy) was given for primary Ewing's sarcoma of the left 6th rib. The tumor became small and was successfully removed at operation. There has been no relapse or distant metastasis for 8 months following the operation. We emphasize the importance of multidisciplinary treatment in case 1 and the usefulness ...

55

Comparison of the radiobiological effect of carbon ion beam therapy and conventional radiation therapy on cervical cancer  

International Nuclear Information System (INIS)

Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant ...

2008-09-01

56

Title of paper: the induction of P-53 independent programmed cell death (apoptosis) with ionizing radiation and 5-fluorouracil (5-FU) in the HT-29 human colon carcinoma cell line  

International Nuclear Information System (INIS)

Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells ...

1996-09-01

57

Tumorigenic and tumoricidal actions of ionizing radiations  

Energy Technology Data Exchange (ETDEWEB)

The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.

1983-01-01

58

Four cases of bowel perforation following radiation therapy for cervical cancer  

Energy Technology Data Exchange (ETDEWEB)

External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.

1984-10-01

59

Results of electron beam therapy using intra-oral cone for carcinoma of the oral tongue  

Energy Technology Data Exchange (ETDEWEB)

Retrospective analyses were performed to evaluate the therapeutic efficacy of intra-oral cone (IOC) radiation therapy for carcinoma of the oral tongue, especially about its faculty of local control and complications. Thirty-nine patients with squamous cell carcinoma of the oral tongue were treated with IOC radiation therapy alone or in combination with external irradiation. IOC radiation therapy was given not only for T1 and T2, but also for T3 tumors. Hypofractionation was used for IOC radiation therapy. The 2 year local control rates, including surgical salvage, for T1, T2, T3 and T4 were 100%, 73.3%, 40% and 0%, respectively. The 5 year actuarial survival rates for Stage I, II, III and IV were 100%, 65.3%, 35.4% and 0%, respectively. The incidences of radiation complications, i.e. soft tissue ...

1992-07-01

60

Fifteen-year follow-up of a patient with beta thalassaemia and extramedullary haematopoietic tissue compressing the spinal cord  

Energy Technology Data Exchange (ETDEWEB)

A long-term follow-up of a patient with beta thalassaemia with intra- and extraspinal extramedullary haematopoietic tissue compressing the spinal cord is presented. Extramedullary haematopoietic nodules are a rare cause of spinal cord compression and should be included in the differential diagnosis, especially in patients from Mediterranean countries. Treatment with radiation therapy solely failed, giving rise to the need of surgical intervention. Surgical decompression of the spine and the removal of the culprit lesion compressing the spine were performed. Postinterventional radiation therapy was applied to the spine. A relapse had to be treated again by surgical means combined with postinterventional radiation therapy. A complete relief of the symptoms and control of the lesion could be obtained.

2005-04-01

61

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

62

Electron beam therapy in carcinoma of the buccal mucosa  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

1990-10-01

63

Electron beam therapy in carcinoma of the buccal mucosa  

International Nuclear Information System (INIS)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

64

The combination therapy with hepatic arterial infusion chemotherapy and radiation therapy for unresected intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

The outcome was retrospectively examined and prognostic factors were discussed for arterial chemo-infusion therapy (ACT) through an implanted reservoir system and radiation therapy (RT) in patients with unresectable intrahepatic cholangiocarcinoma (CCC). ACT plus RT were conducted to 25 patients (mean age 61.7 y, M/F 12/13, stage III-IVB) during 10 years from 1996 to 2005 with various regimens of cisplatin (CDDP), 5- fluorouracil (FU), epirubicin (FARM), mitomycin C (MMC) plus 39-50 Gy of radiation in a fractionated manner partly involving internal RT (2 cases, 15 Gy) and RT for metastatic bone (1, 25 Gy). The survival rates at 1, 2 and 3 years after ACT+RT were respectively 52.5, 43.7 and 28.1%; total efficacy (PR) was 36% (9/25) at 6 months; and significantly good prognostic factors were found to be female and absence of metastasis remote and/or lymphatic around artery. Authors concluded that ACT+RT ...

2007-11-01

65

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63  

International Nuclear Information System (INIS)

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical ...

2003-06-01

66

Electron beam intraoral cone therapy in carcinoma of tongue. Report of eight cases and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

The clinical results of electron beam therapy using intraoral cone in 8 cases of primary and recurrence carcinoma of tongue (T1 and smaller T2) were reported. The primary and recurrence cases were 5 and 3, respectively. In the 5 cases, a total dose of 10-30 Gy external radiation therapy were combined prior to electron beam therapy. The total dose of electron beam therapy varied from 40 to 60 Gy. In all cases, tumor showed good response and disappeared clinically. Radiation stomatitis, pain of the tongue with masticatory disturbance due to tenderness were complicated in all cases. These complications gradually disappeared 2 to 6 months after treatment. However, loss of body weight and bone exposure were not recognized in any case. Intraoral-cone electron beam therapy is thought to be available and has less complications comparing interstitial ...

1989-06-01

67

Bullous pemphigoid after radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.

1988-02-01

68

Difference between delayed radiation-necroses of the cerebral hemispheres and midline: its bearing in radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.

1980-08-01

69

What's new in target volume definition for radiologists in ICRU Report 71? How can the ICRU volume definitions be integrated in clinical practice?  

UK PubMed Central (United Kingdom)

AbstractThe optimal definition of the size, shape and location of gross tumour volume is one of the most important steps in the planning of radiation therapy, and necessitates a proper...Full Text Available

70

Subacute neuropathological effects of microplanar beams of x-rays from a synchrotron wiggler.  

UK PubMed Central (United Kingdom)

Microplanar beam radiation therapy has been proposed to treat brain tumors by using a series of rapid exposures to an array of parallel x-ray beams, each beam having uniform microscopic thickness and...Full Text Available

1995-09-12

71

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... 46 DOUGLAS BOCCUZZI, MS, DABR: There are some electromagnetic fields in the room, not strong. You can ... 5 weeks or is she feeling any side effects? 00:43:33 SUSAN Y. KIM, MD: She ...

72

Risedronate Prevents Early Radiation-Induced Osteoporosis in Mice at Multiple Skeletal Locations  

UK PubMed Central (United Kingdom)

IntroductionIrradiation of normal, non-malignant bone during cancer therapy can lead to atrophy and increased risk of fracture at several skeletal sites, particularly...Full Text Available

2010-01-01

73

Radiation Therapy and Psychological Distress in Gynecologic Oncology Patients: Outcomes and Recommendations for Enhancing Adjustment  

UK PubMed Central (United Kingdom)

SummaryRadiotherapy is used commonly in the treatment of gynecologic malignancies. Many patients experience emotional distress prior to the initiation of radiotherapy, during...Full Text Available

1986-01-01

74

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

76

Excessive Soft Tissue Reaction after Stereotactic Body Radiation Therapy in a Woman with Four Different Cancer Diagnoses  

UK PubMed Central (United Kingdom)

Patients experiencing several cancers can be a challenge, as optimal treatment options for the different cancers might interfere with each other. In this case report, we present a woman diagnosed with...Full Text Available

77

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers  

UK PubMed Central (United Kingdom)

Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available

78

Comparison of coplanar and noncoplanar intensity-modulated radiation therapy and helical tomotherapy for hepatocellular carcinoma  

UK PubMed Central (United Kingdom)

BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available

79

Bleeding during cancer treatment: MedlinePlus Medical Encyclopedia  

Science.gov (United States)

- flushing Chemotherapy - what to ask your doctor Dry Mouth Oral mucositis Peripherally inserted central catheter Radiation therapy - what to ask your doctor Safe drinking during...

2011-08-09

80

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

81

Long-term results in 144 localized Ewing's sarcoma patients treated with combined therapy  

International Nuclear Information System (INIS)

The results of 144 previously untreated cases of primary Ewing's sarcoma of bone are reported with a minimum follow-up of 5 years. This series was treated between 1972 and 1982 at Istituto Ortopedico Rizzoli with a combined therapy. The local control of the disease consisted of amputation (ten cases), resection followed by radiation therapy (35-45 Gy) (48 cases) and radiation therapy alone (40-60 Gy) (86 cases). Adjuvant chemotherapy, rigorously standardized, was performed according two different protocols: the first (85 cases treated in the period 1972-1978) consisted of vincristine (VCR) Adriamycin (doxorubicin) (ADM), and cyclophosphamide (EDX); the second (59 cases treated in the period 1979-1982) of VCR, ADM, EDX and dactinomycin (DACT). At a follow-up of 5 to 16 years (median, 9), 59 patients (41%) are continuously disease-free (CDF), 81 (56%) developed metastatic disease ...

82

Hanford Internal Dosimetry Program Manual, PNL-MA-552  

Energy Technology Data Exchange (ETDEWEB)

This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

2009-09-24

83

Multiple courses of high-dose total skin electron beam therapy in the management of mycosis fungoides  

International Nuclear Information System (INIS)

Purpose: A retrospective analysis was undertaken to determine the indications for, the efficacy of, and the long-term complications of two courses of total skin electron beam therapy for mycosis fungoides. Methods and Materials: A retrospective analysis of 15 patients with the pathologic diagnosis of mycosis fungoides treated in the Department of Radiation Oncology at Stanford University Medical Center between 1968 and 1990 was performed. All patients received two courses of high-dose electron beam therapy to the skin. The mean dose for the total skin treatment for the first course was 32.6 Gy and 23.4 Gy for the second course of treatment. Results: Following the first course of total skin electron beam therapy, 11 of 15 had a complete response, with a mean duration of 11.6 months. All patients received adjuvant therapies between the first and second courses of high-dose total skin ...

1995-07-30

84

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide ...

2003-01-01

85

Development and clinical experience of C-arm type radiosurgery system or three dimensional therapy system  

Energy Technology Data Exchange (ETDEWEB)

Authors developed a C-arm type radiosurgery system of the linear accelerator suitable for stereotactic radiation therapy and a software for arranging 3-dimensional therapy in the system. In this system, the gantry far conical irradiation of 4 MV (0.6-3 Gy/min) and 6 MV (0.9-4.5 Gy/min) X ray or electron beam for the therapy was connected to a newly designed C-arm and was made capable of rotating around either of the axes crossing vertically. With this system, it became unnecessary to move the bed table of the patient for getting suitable distribution of radiation dose. The local accuracy which was measured by the CCD videocamera on the gantry, was within 0.5 mm from the radiation center. The system made it possible to shorten the irradiation time and to improve the local accuracy of irradiating site. The clinical trial was begun from June, 1996. (K.H.)

1996-10-01

86

The advancement of stem cells in radiation medicine  

International Nuclear Information System (INIS)

It may result in acute radiation syndrome after body is exposed to ionizing radiation. The one of long-term effects of irradiation injury is leukemia. The bone marrow cells (BMC) transplantation including stem cells is the only effective therapy for acute radiation syndrome patients. Recently, with the advancement of stem cell research that the stem cells have multipotential and can convert each other, it may supply the new stem source for the irradiation injury patients. At the same time with the further research of radioprotective reagents, the hematopoietic stem cells proliferation after irradiation injury is promoted

2003-02-01

87

RADSOLVER: a computer program for calculating spectrally-dependent radiative heat transfer in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.

1981-09-01

88

The efficacy of low-dose radiation therapy and surgical resection for Ewing's sarcoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the effect of low-dose radiation therapy and surgery on local control in patients with Ewing's Sarcoma. Materials and Methods: Between 1979 and 1995 24 patients (ages 4-47) with Ewing's sarcoma were treated with combined modality therapy that included multi agent chemotherapy, surgical resection, and radiation therapy. Twelve patients had metastatic disease at the time of presentation (pleura = 3, lung = 5, bone 4). Tumor location was central in 16 and peripheral in 8. Multi agent chemotherapy consisted of vincristine/actinomycin D/cyclophosphamide/doxorubicin in 19. The same agents with the addition of ifosfamide and etoposide were given in 5. The extent of resection was considered to be radical in 14 and of the 16 patients who received preoperative chemotherapy, 5 were found to have a pathologic complete response. All patients with lung metastases at diagnosis ...

1996-09-01

89

Efficacy and toxicity of replication-competent adenovirus-mediated double suicide gene therapy in combination with radiation therapy in an orthotopic mouse prostate cancer model  

International Nuclear Information System (INIS)

Purpose: The purpose of this study was to evaluate the efficacy and toxicity of replication-competent adenovirus-mediated double suicide gene therapy in an adjuvant setting with external beam radiation therapy (EBRT) in an experimental prostate cancer model in preparation for a Phase I clinical study in humans. Methods: For efficacy studies, i.m. DU145 and intraprostatic LNCaP C4-2 tumors were established in immune-deficient mice. Tumors were injected with the lytic, replication-competent Ad5-CD/TKrep adenovirus containing a cytosine deaminase (CD)/herpes simplex virus thymidine kinase (HSV-1 TK) fusion gene. Two days later, mice were administered 1 week of 5-fluorocytosine + ganciclovir (GCV) prodrug therapy and fractionated doses of EBRT (trimodal therapy). Tumor control rate of trimodal therapy was compared to that of EBRT alone. For toxicology studies, ...

2002-11-01

90

Use of absorbable mesh to displace bowel and avoid radiation enteropathy, during therapy of pelvic Ewing's sarcoma  

International Nuclear Information System (INIS)

The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).

91

Combined therapy of localized Ewing's sarcoma of bone: Analysis of results in 100 patients  

International Nuclear Information System (INIS)

From 1979 to 1986, 182 patients with biopsy proven diagnosis of Ewing's sarcoma of bone were observed. One hundred of the 182 patients (72 males, 28 females, median age 15.8 years) with localized disease and no previous treatment were treated with chemotherapy (VCR, ADM, CTX, D-ACT) for 15-18 months. Local treatment was radiotherapy (42 patients), surgery (31 patients), or a combination of both (27 pts). Radiation doses ranged from 45 to 64 Gy given with conventional fractionation. Median follow-up was 51.2 months (24-106). Overall and disease-free survival were, respectively, 58.7 and 42.6%. Resected patients tended to have a better local control (Surgery 93.6%, Surgery + Radiation therapy 92.6%, Radiation therapy 69.1%). Disease-free survival was significantly related to the volume of the primary tumor (bulky: 33.2%, not-bulky: 57.7%), to site (extremities 54.6%, central sites ...

92

The enteral probe nutrition with Cosilat in complex therapy of patients with radiotherapeutic late effects of the colon  

International Nuclear Information System (INIS)

Results are presented applying an enteral nutrition by means of probes with Cosilat in complex therapy of patients with radiotherapeutic late effects of the colon. This nutrition was prescribed with the intention to gave the colon a functional recovery and to guarantee optimal conditions for repair of radiation injuries. Good results were seen in 27 of 28 patients (96.7%), the situation of one patient (3.3%) continued without any change. Cosilat has a high nutritive value, good organoleptic qualities and is well digested without any complications. (author).

93

Megavoltage electron beam therapy in the treatment of basal and squamous cell carcinomata of the pinna  

Energy Technology Data Exchange (ETDEWEB)

Forty-three patients with basal and squamous cell carcinomata arising on the pinna were treated radically using a 10 MeV electron beam. The technique and dosage are described and discussed. Primary cancer control with retention of the pinna was achieved in 34 patients. Salvage pinnectomy was performed in four patients for recurrence and one patient for radiation necrosis. Two patients with large primary tumours failed to resolve and died of their disease. The advantages for the patient of the policy of primary radical electron beam therapy are discussed.

1982-05-01

94

Guidelines on the medical therapy of persons accidentally overexposed to ionizing radiations. External contamination  

International Nuclear Information System (INIS)

The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)

95

A Year of Radiation Measurements at the North Slope of Alaska Second Quarter 2009 ARM and Climate Change Prediction Program Metric Report  

Energy Technology Data Exchange (ETDEWEB)

In 2009, the Atmospheric Radiation Measurement (ARM) Program and the Climate Change Prediction Program (CCPP) have been asked to produce joint science metrics. For CCPP, the second quarter metrics are reported in Evaluation of Simulated Precipitation in CCSM3: Annual Cycle Performance Metrics at Watershed Scales. For ARM, the metrics will produce and make available new continuous time series of radiative fluxes based on one year of observations from Barrow, Alaska, during the International Polar Year and report on comparisons of observations with baseline simulations of the Community Climate System Model (CCSM).

2009-04-15

96

CRC handbook of management of radiation protection programs  

Energy Technology Data Exchange (ETDEWEB)

This guidebook organizes the profusion of rules and regulations surrounding radiation protection into a single-volume reference. Employee and public protection, accident prevention, and emergency preparedness are included in this comprehensive coverage. Whenever possible, information is presented in convenient checklists, tables, or outlines that enable you to locate information quickly.

1986-01-01

97

The medical exposures to ionizing radiations, it is a world priority in radiation protection  

International Nuclear Information System (INIS)

The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)

98

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the ...

1991-06-01

99

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

Energy Technology Data Exchange (ETDEWEB)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left ...

1994-10-01

100

Large intracranial vessel occlusion arising after radiotherapy for craniopharingioma. A case report and review of the literature  

International Nuclear Information System (INIS)

We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left ...

1994-01-01

101

Biological Research for Radiation Protection  

International Nuclear Information System (INIS)

The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect ...

102

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...

2007-01-01

103

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

British Library Electronic Table of Contents (United Kingdom)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...

2009-01-01

104

References | Radiation Protection | US EPA  

Wastenet

...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...

105

Effective dose estimation in whole-body multislice CT in paediatric trauma patients  

Energy Technology Data Exchange (ETDEWEB)

The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the ...

2009-03-15

106

INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.

1997-04-01

107

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

108

Oligodendroglioma occurring after radiation therapy for pituitary adenoma  

Energy Technology Data Exchange (ETDEWEB)

A 38 year old male dentist developed an oligodendroglioma of the left medial temporal lobe and parasellar region 12 years after radiotherapy with 6600 rads for acromegaly. The 30 cases of radiation-induced gliomas reported in the English literature are reviewed and analysed. The criteria for defining radiation-induced tumours of the central nervous system are proposed as follows: the tumour has a long quiescent ''latency period'', a location in the previously irradiated field, a verified histological difference from a primary condition, and does not arise from a primary condition associated with a genetic syndrome such as neurofibromatosis or tuberous sclerosis. The reported case fulfilled these criteria but appears to be the only reported radiation-induced oligodendroglioma.

1987-12-01

109

Palliation of radiation-related mucositis  

Energy Technology Data Exchange (ETDEWEB)

Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.

1990-01-01

110

Oncogenic transformation produced by agents and modalities used in cancer therapy and its modulation  

International Nuclear Information System (INIS)

The long-term survival of certain patients after treatment with radiation or chemotherapeutic agents has allowed the realization that agents that effectively control cancer in the human subject may also possess an oncogenic potential, resulting in secondary malignancies in a significant proportion of surviving patients. A quantitative assessment of the oncogenic effects of these agents at a cellular level is important, as is information on conditions and agents that may effectively alter the development of the neoplastic state. Cell culture systems where the neoplastic transformation of cells can be scored after exposure to carcinogens offer powerful tools for evaluating the oncogenic potential of radiation and chemotherapeutic agents.

1982-01-01

111

Tritium bioassay and dosimetry at a CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.

1996-07-01

112

Annual Radiological Environmental Monitoring Program Report for the Fort St. Vrain Independent Spent Fuel Storage Installation (2005)  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of the 2003 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.

2001-02-01

113

Annual Radiological Environmental Monitoring Program Report for the Fort St. Vrain Independent Spent Fuel Storage Installation  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of the 2001 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct and scattered radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.

2002-02-01

114

Radiation Dosimetry considerations in the safe administration of therapeutic radiopharmaceuticals  

Energy Technology Data Exchange (ETDEWEB)

A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.

1995-12-01

115

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

116

Dosimetric Evaluation of Heterogeneity Corrections for RTOG 0236: Stereotactic Body Radiation Therapy of Inoperable Stage I/II Non-Small Cell Lung Cancer  

UK PubMed Central (United Kingdom)

PurposeUsing a retrospective analysis of treatment plans submitted from multiple institutions accruing patients to the RTOG #0236 non-small cell SBRT protocol, this...Full Text Available

2009-03-15

117

A computer program for estimating decommissioning costs for light water reactors  

Energy Technology Data Exchange (ETDEWEB)

This report discusses a desk-top computer program has been developed for estimating the costs, waste volumes, and occupational radiation exposures associated with decommissioning light-water reactor power stations. Cost categories and cost algorithms used in the program are discussed and a brief description of the user interface is given.

1993-02-01

118

Radiation therapy for Ewing's sarcoma: Results from Memorial Sloan-Kettering in the modern era  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of ...

2006-02-01

119

Spinal Cord Injury  

Medline Plus

... or she will start intensive rehabilitation. This includes physical therapy and occupational therapy. Physical and occupational therapies aim at strengthening the remaining ...

121

Review of theories on ionization in fast ion-atom collisions with prospects for applications to hadron therapy  

British Library Electronic Table of Contents (United Kingdom)

This study emphasizes the need for a systematic and in-depth connection between the progress in quantum theory of energetic ion collisions and applications to hadron therapy. Scattering theory for fast ion beams has reached its stage of development where accurate and robustly applicable methodologies can advantageously be exported to applied fields such as space research, fusion energy program, medicine, etc. In particular, distorted wave collision theories at high energies readily provide total, partial and fully differential cross sections for inelastic collisions of ionic projectiles with any target system. By numerous and thorough testings, such theoretical cross sections were found to exhibit excellent agreement with experimental data on atomic targets. Adequate extensions of these me...

2010-01-01

122

Physical therapy for chronic pain conditions—A novel approach using mind–body connection  

British Library Electronic Table of Contents (United Kingdom)

The treatment of chronic pain conditions continue to present a challenge to the medical field. Physical therapy treatment needs to approach the management of chronic pain differently than the approach used to resolve acute pain. Patients with chronic pain often have many factors that have perpetuated the pain condition. These factors, as well as pain itself, influence their ability to reactivate and perform functional daily activities. Physical therapists can begin to address some of the factors, including fear and deconditioning, by building confidence and body awareness in a self-care model including a slow graduated reactivation program. There is evidence that patients with chronic pain conditions have altered motor control that may be influencing reoccurrences and possible flares of pa...

2011-01-01

123

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic ...

2007-08-21

124

Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study  

International Nuclear Information System (INIS)

Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer ...

2010-01-01

125

Analysis of Result of Treatment of Ewing's Sarcoma  

International Nuclear Information System (INIS)

Total 125 patients with primary and metastatic Ewing's sarcoma were treated in various ways between 1963 to 1977. Patients were divided into 3 groups according to the treatment methods. Group 1 was nonprotocol patients with or without chemotherapy. Total 58 patients were entered. Group 1 was divided into 2 subgroups. 33 patients were treated locally without chemotherapy and 25 patients were treated with local therapy and nonprotocol chemotherapy. Group 2 was treated with local therapy and plus T-2 regimen multiagent chemotherapy. 29 patients were entered. Group 3 was treated with local therapy and T-6 regimen multiagent chemotherapy. 38 patients were entered. Local treatments for primary tumor were surgery and/or radiation therapy. Radiation dose ranged between 2,000 and 8,000 rad. Patients with pulmonary metastases received bilateral pulmonary RT. Local ...

1984-06-01

126

The radon therapy - radon inhalatorium in Kowary  

International Nuclear Information System (INIS)

In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)

127

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood; Aktuelle und zukuenftige Strategien in der interdisziplinaeren Therapie von Medulloblastomen, supratentoriellen PNET und intrakraniellen Keimzelltumoren im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting germ cell tumors ...

2001-09-01

128

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

International Nuclear Information System (INIS)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...

2009-10-01

129

Different techniques for measuring radon concentration in a spa environment  

International Nuclear Information System (INIS)

In the context of radiation protection for both workers and the population in general, natural sources of radiation, and in particular radon gas and its short-life decay products assume great importance. In particular, workers in thermal spas can easily be exposed to a level of radon radiation and its decay products comparable to those in uranium mines, though often these workers are unaware of the danger. The main source of radon in thermal baths is the thermal water itself, coming as it often does from deep springs, and this can produce high radon concentrations which are left in those areas in which therapy is carried out. Another factor which cannot be overlooked is the radioactive content of thermal mud, often matured for long periods by contact with thermal water. Thermal cures, though varying slightly from site to site, consist principally of mud cures, hydro-therapy and ...

2002-10-08

130

Short-term inhibition of ADP-induced platelet aggregation by clopidogrel ameliorates radiation-induced toxicity in rat small intestine.  

Science.gov (United States)

Endothelial dysfunction and increased platelet aggregation may be involved in the pathogenesis of normal tissue radiation toxicity. This study assessed clopidogrel, an inhibitor of ADP-induced platelet aggregation, as a modulator of intestinal radiation injury (radiation enteropathy). Rat small intestine was exposed to 21 Gy X-radiation. Clopidogrel (20 mg/kg/day) or vehicle was administered from 2 days before to 10 days after irradiation. Structural radiation injury, neutrophil infiltration, smooth muscle cell proliferation, collagen content, and TGF-beta1 expression were assessed 2 weeks (early phase) and 26 weeks (delayed phase) after irradiation, using quantitative histology and immunohistochemistry, morphometry, and real-time fluorogenic probe RT-PCR. Irradiated intestine exhibited significant histopathologic injury, reduced mucosal surface area, vascular sclerosis, intestinal ...

2002-01-01

131

Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice  

International Nuclear Information System (INIS)

A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse cytophotometry, "3H-thymidine uptake labeling ...

132

In vitro study of plutonium in macrophages  

International Nuclear Information System (INIS)

An in vitro system for studying Pu uptake by, and removal from, macrophages was developed to provide data for the actinide therapy program. We have shown that "2"3"9PuO_2 particle uptake in vitro resembles the process in vivo with respect to the intracellular localization of phagocytized particles. At the end of 7 days of culture of Pu-loaded cells, 54% of the cells were viable even though 71% of the cells in the culture initially contained enough "2"3"9PuO_2 to deliver more than 53 intracellular #alpha#-disintegrations.

1977-05-01

133

Exposure estimation of personnel around patients after radionuclide therapy by Monte Carlo method and integration method  

International Nuclear Information System (INIS)

Objective: To estimate exposure dose of personnel around patients by Monte Carlo method and integration method. Methods: Exposures were estimated by a Monte Carlo practical program with Visual Basic 6.0 and integration method using 'pen-and-paper'. Results: Exposures for rectangle and ellipse sources were calculated. The difference between different methods for various sources were 0.88% and 0.61%, respectively. Conclusion: The results estimated by Monte Carlo method are close to those of integration method. It is illustrated that doses of other people estimated by Monte Carlo method are significant

2001-08-01

134

Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System  

Energy Technology Data Exchange (ETDEWEB)

RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery ...

1998-01-16

135

A Two-step Intensity-modulated Radiation Therapy Method for Nasopharyngeal Cancer: The Kinki University Experience  

British Library Electronic Table of Contents (United Kingdom)

Objective The aim of this study was to analyze the clinical results of our adaptive radiation therapy scheme of a two-step intensity-modulated radiotherapy (IMRT) method for nasopharyngeal cancer (NPC) at Kinki University Hospital. Methods Between 2000 and 2007, 35 patients with Stage I-IVB NPC treated by IMRT were included. For all patients, treatment-planning computed tomography was done twice before and during IMRT to a total dose of 60-70 Gy/28-35 fractions (median 68 Gy). Chemotherapy (cisplatin 80 mg/m2/3 weeks x 1-3 courses) was given concurrently with IMRT for 31 patients. Results The 3- and 5-year overall survival rates for the 31 patients treated with concurrent chemotherapy were 88% and 83%, respectively. The 3- and 5-year loco-regional control rates for the 31 patients were 93%...

2010-01-01

136

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

137

Radiation hardening of a high voltage IC technology (BCDMOS)  

International Nuclear Information System (INIS)

A program was undertaken to radiation harden an existing power integrated circuit technology (BCDMOS) to total dose, gamma dot, SEU, and neutrons. Efforts have centered around hardening and optimizing our CMOS, DMOS, and NPN devices. Initial results indicate a substantial improvement in hardness over our existing commercial technology.

1990-07-16

138

Health and Safety Research Division progress report for the period October 1, 1991--March 31, 1993  

International Nuclear Information System (INIS)

This is a progress report from the Health and Safety Research Division of Oak Ridge National Laboratory. Information is presented in the following sections: Assessment Technology, Biological and Radiation Physics, Chemical Physics, Biomedical and Environmental Information Analysis, Risk Analysis, Center for Risk Management, Associate Laboratories for Excellence in Radiation Technology (ALERT), and Contributions to National and Lead Laboratory Programs and Assignments--Environmental Restoration.

1998-06-01

139

The course, diagnosis and treatment of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

Advances in the diagnosis of Ewing's sarcoma of the rib were considered and retrospective analysis of the treatment of 32 patients (76% of them were children at the age of 10-15 y.o.) in the clinic of children oncology was performed. It was shown that the diagnosis of Ewing's sarcoma of the rib in children ought to be combined taking into account the course, morphology and radiation examination techniques. Most optimum treatment consisted of combined therapy (cyclic polychemotherapy, lesion focus irradiation at the summary focus dose of 57 Gy, surgery with subsequent polychemotherapy for not less than 1.5 years

1997-11-18

140

Ewing's sarcoma of the humerus mimicking fibrous dysplasia on imaging and biological behavior  

International Nuclear Information System (INIS)

We present the case of a 12-year-old girl who presented with a pathological fracture through a benign-appearing osteolytic lesion that was presumed to represent fibrous dysplasia. The fracture healed, and over the next 2.5 years there was further refracturing and healing with progressive osteolysis. A biopsy was performed and revealed Ewing's sarcoma. The disease was locally controlled by neoadjuvant chemotherapy and radiation therapy. The patient is disease free with excellent function 6 years following the discovery of the lesion. We illustrate and discuss the sequence of events. (orig.)

2005-05-01

141

Drug eruptions presenting at sites of prior radiation damage (sunlight and electron beam)  

Energy Technology Data Exchange (ETDEWEB)

Two patients are described in whom sunburn and electron beam radiodermatitis, respectively, were critical determinants in localizing the initial presentation of drug eruptions. In the first instance, a severe sunburn of the back and thighs was followed 7 months later by the appearance of a toxic epidermal necrolysis drug reaction to trimethoprim-sulfamethoxazole in the exact sites of the previous bullous sunburn reaction. In the second patient, a radiodermatitis of the left upper arm due to electron beam therapy for metastatic breast cancer was followed 7 weeks later by a codeine drug reaction confined to the area of the radiodermatitis. In both instances, oral rechallenge with the offending drug reproduced the eruption.

1984-07-01

142

Animal experiments on the biokinetics of astatide and astate-(I)-complex compounds  

International Nuclear Information System (INIS)

The radiation properties of the #alpha# emitter "2"1"1At are in favor of its application malignant tumor therapy. As a basis for further investigations the biokinetics of At"-, At x H_2O, At I_2"-, and [At(thio)_2]"+ were determined after i.v. injection into healthy and tumor-bearing mice. The estimation of the ion mobility of the carrier-free compounds allowed the use of uniquely characterized initial compounds. The organ distribution of all species examined was similar to the distribution of astatide. Accumulation was found in the thyroid and other inner organs. (author).

143

A case of Ewing's sarcoma treated successfully with chemotherapy and radiotherapy  

International Nuclear Information System (INIS)

We encountered a case of Ewing's sarcoma. The patient was a 19 year-old girl, who visited a local physician because of pain in the left scapular region, and was referred to us. Roentgenograms of her left scapula revealed an irregular moth-eaten shadow which was suspected to be a malignant bone tumor. The histological diagnosis of Ewing's sarcoma was comfirmed by needle biopsy. The initial stage of treatment consisted of radiation therapy (6000 rads) and chemotherapy (VAC and ADR). At the end of the initial stage, the symptoms were improved, the size of the local lesion was reduced on the roentgenogram and there was no evidence of distant metastases. (author).

144

Pirfenidone in idiopathic pulmonary fibrosis: the CAPACITY program  

British Library Electronic Table of Contents (United Kingdom)

Idiopathic pulmonary fibrosis is the most lethal form of diffuse lung fibrosis, killing approximately half of those affected within 2-3 years of diagnosis. Until recently, no therapies had been shown to have an impact on disease progression. The Clinical Studies Assessing Pirfenidone (Esbriet) in IPF: Research of Efficacy and Safety Outcomes (CAPACITY) program comprised two almost identical double-blind placebo-controlled studies assessing the effects of pirfenidone on change in forced vital capacity, the primary end point, over a 72-week period. One of these studies was positive, matching in magnitude the benefit seen in two previous positive Japanese studies. The other study did not meet its primary end point but positive trends were consistent in this and a number of secondary end point...

2011-01-01

145

Radiation safety in industrial applications  

International Nuclear Information System (INIS)

Oil and gas industry is the largest user of radioactive materials in Nigeria. They make use of radiation generators, sealed and unsealed radioactive sources.Some of these are potentially dangerous to human health and environment if not properly controlled. here is also the need to maintain control over occupational exposures to radiation, as well as to protect the public and the environment through proper management of wastes that may be radiologically hazardous. To minimize these, effective regulatory infrastructure is being put in place.For a smooth take-off of the nuclear power program, the National Nuclear Regulatory Authority and other stake holders in the nuclear industry need to start to put together licensing procedure for these.

2008-03-17

146

Epidemiological studies of radiation carcinogenesis and its biophysical basis  

International Nuclear Information System (INIS)

The three projects of the research program are aimed at the epidemiological study of long-term radiation effects in patients injected with radium-224. They are: late effects in "2"2"4Ra treated ankylosing spondylitis patients, late effects in "2"2"4Ra treated juvenile and adult patients, and epidemiology of radiation carcinogenesis. The data from these patients are a unique source of information for risk analysis of incorporated bone seeking radionuclides in man. (R.P.) 5 refs., 3 tabs.

147

The Differentially Expressed Genes by Radiotherapy in the Patients with Uterine Cervix Cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose : To detect differentially expressed genes in the patients with uterine cervical cancer during the radiation therapy. Materials and Methods : In patients with biopsy proven uterine cervical cancer, we took a tumor tissue just before radiation therapy and at 40 minutes after external irradiation of 1.8 Gy. Total RNAs isolated from non-irradiated and irradiated tumor tissue samples were analyzed using the differential-display reverse transcription-polymerase chain reaction (DDRT-PCR). Complementary DNA (cDNA) fragments corresponding to differentially expressed messenger RNAs(mRNAs) were eluted, and cloned. The differential expression of the corresponding mRNAs was confirmed by reverse northern blot. Differentially expressed cDNA bands were sequenced. Nucleotide sequence data were analyzed in the Gene Bank and EMBL databases via the BLAST network server to identify homologies to known genes or cDNA ...

2001-12-15

148

Hyperfractionated radiation therapy for incompletely resected supratentorial low-grade glioma. A phase II study  

International Nuclear Information System (INIS)

Background and purpose: In order to investigate the feasibility, toxicity and antitumor efficacy of hyperfractionated radiation therapy, 37 adult patients with incompletely resected supratentorial low-grade glioma were entered into a phase II study. Materials and methods: The radiation therapy dose was 55 Gy in 50 fractions in 25 treatment days over 5 weeks to the tumor plus a 2-cm margin, with an additional 17.6 Gy given in 16 fractions in 8 treatment days over 1.5 weeks to the tumor plus a 1-cm margin, using 1.1 Gy b.i.d. fractionation with a 6 h interfraction interval. The total tumor dose was 72.6 Gy in 66 fractions in 33 treatment days over 6.5 weeks. Results: The median survival time (MST) for all 37 patients has not yet been attained, while 5- and 7-year survival rates were 75% and 69%, respectively. The median time to tumor progression (MTP) has also not yet been attained, while 5- and 7-year ...

1998-10-01

149

Evaluation of indexes for tumor growth and effect of radiation therapy using MRS; Experimental studies on SCCVII tumor bearing mice  

Energy Technology Data Exchange (ETDEWEB)

Changes in the phosphate metabolism of the transplanted SCCVII (squamous cell carcinoma VII) tumor were studied before and after irradiation using in vivo [sup 31]P-magnetic resonance spectroscopy (MRS). Phosphocreatine (PCr), [gamma]-, [alpha]-, [beta]-ATP, inorganic phosphate (Pi), phosphomonoester (PME), and phosphodiester (PDE) were detected in [sup 31]P-MR spectra of tumor tissues. The curve fitting method was employed for calculating each peak of [sup 31]P-MR spectra (PCr, [beta]-ATP, Pi, PME, PDE). The values of PCr, PCr/Pi, [beta]-ATP/Pi and pH decreased in proportion to the growth of tumor, whereas that of Pi, PME and PDE increased. But the changes of [beta]-ATP were minimal in degree. Based on the fact that the ratio of PCr/Pi highly correlated with tumor volume and showed the most remarkable change among various parameters, it might be the useful index for the tumor growth. Because the phospholipid metabolite PME was detected in the earlier stage of tumor growth, PME might ...

1992-03-01

150

Difference in prognostic factors between stage IB and II uterine cervical carcinoma patients treated with radical hysterectomy and postoperative radiation therapy  

International Nuclear Information System (INIS)

The purpose of the current study was to evaluate the difference in prognostic factors between stage IB and II uterine cervical carcinoma patients treated with postoperative radiation therapy. Between May 1988 and May 1998, a total of 94 patients including 47 patients with stage IB and 47 patients with stage II uterine cervical carcinoma were treated with postoperative radiation therapy at Tokyo Metropolitan Komagome Hospital. All patients were treated with 10 MV X-rays using an anterior-posterior parallel opposed field which covered the whole pelvis. Fractionation was 2 Gy per day, five fractions per week, to a total dose of 50 Gy. The 5-year overall survival rates of stage IB and II were 89.4% and 79.3%, respectively. In multivariate analysis for all patients, lymph node status, histology, and surgical margin status were recognized as prognostic factors. Limited to stage IB patients, lymph node status ...

151

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

152

Modulation of the intestinal response to ionizing radiation by anticoagulant and non-anticoagulant heparins.  

Science.gov (United States)

Endothelial dysfunction is involved in radiation responses in many normal tissues, including intestine. Endothelium-directed interventions ameliorate intestinal radiation injury (radiation enteropathy) in animal models, and anecdotal reports also suggest a beneficial effect of heparin. This study assessed low molecular weight heparin as an intestinal radiation response modifier. Rats underwent localized small bowel irradiation. Groups of rats were treated with saline, nadroparin (3 mg/kg/d), or a non-anticoagulant heparin (SR80258, 3 mg/kg/d), from 3 days before to 2 weeks after irradiation. The intestinal radiation response was assessed 2 weeks and 6 weeks after irradiation using quantitative histology; morphometry, and cellular and molecular end-points. Compared to vehicle-treated controls, nadroparin significantly exacerbated structural radiation injury, ...

2005-11-01

153

Assessment and control of fetal exposure  

Energy Technology Data Exchange (ETDEWEB)

The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, ...

1991-10-01

154

Self-assessment of current knowledge in nuclear medicine (second edition)  

Energy Technology Data Exchange (ETDEWEB)

In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...

1981-01-01

155

Status of safety at Areva group facilities. 2007 annual report; Areva, etat de surete des installations nucleaires. Rapport annuel 2007  

Energy Technology Data Exchange (ETDEWEB)

This report describes the status of nuclear safety and radiation protection in the facilities of the AREVA group and gives information on radiation protection in the service operations, as observed through the inspection programs and analyses carried out by the General Inspectorate in 2007. Having been submitted to the group's Supervisory Board, this report is sent to the bodies representing the personnel. Content: 1 - A look back at 2007 by the AREVA General Inspector: Visible progress in 2007, Implementation of the Nuclear Safety Charter, Notable events; 2 - Status of nuclear safety and radiation protection in the nuclear facilities and service operations: Personnel radiation protection, Event tracking, Service operations, Criticality control, Radioactive waste and effluent management; 3 - Performance improvement actions; 4 - Description of the General Inspectorate; 5 - ...

2007-07-01

156

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three dose components; namely 1) dose from useful beams; 2) scattered radiation dose from ...

1981-01-01

157

Molecular targeted treatment and radiation therapy for rectal cancer  

Energy Technology Data Exchange (ETDEWEB)

Background: EGFR (epidermal growth factor receptor) and VEGF (vascular endothelial growth factor) inhibitors confer clinical benefit in metastatic colorectal cancer when combined with chemotherapy. An emerging strategy to improve outcomes in rectal cancer is to integrate biologically active, targeted agents as triple therapy into chemoradiation protocols. Material and methods: cetuximab and bevacizumab have now been incorporated into phase I-II studies of preoperative chemoradiation therapy (CRT) for rectal cancer. The rationale of these combinations, early efficacy and toxicity data, and possible molecular predictors for tumor response are reviewed. Computerized bibliographic searches of Pubmed were supplemented with hand searches of reference lists and abstracts of ASCO and ASTRO meetings. Results: the combination of cetuximab and CRT can be safely applied without dose compromises of the respective treatment components. Disappointingly low ...

2009-06-15

158

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD) (follicle-stimulating hormone (FSH), 10 +/- 15 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 ..beta..-estradiol (E/sub 2/) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developd persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 109 +/- 29 mlU/ml; LH, 72 +/- ...

1981-12-01

159

Effects of postoperative adjuvant chemotherapy and radiotherapy on ovarian function in women undergoing treatment for soft tissue sarcoma  

Energy Technology Data Exchange (ETDEWEB)

Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD (follicle-stimulating hormone (FSH), 10 +/- 5 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 beta-estradiol (E2) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developed persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 108 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) ...

1981-12-01

163

Massage Therapy  

Medline Plus

... Massage therapy can help the body release certain chemicals. These chemicals help us relax, improve blood circulation and get ...

164

Verification of electron beam therapy with storage phosphor images: Precision of field placement  

Energy Technology Data Exchange (ETDEWEB)

Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron treatments should be similar to the emphasis placed on this aspect ...

1990-04-01

165

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable ...

2005-01-01

166

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable to ...

2005-01-01

167

Severe rectal injury following radiation for prostatic cancer  

Energy Technology Data Exchange (ETDEWEB)

Between 1970 and 1981, 348 patients underwent definitive irradiation. Of these patients 6 (1.7 per cent) sustained severe rectal injury as manifest by major rectal bleeding, rectal stricture, rectal mucosal slough and rectal ulceration. Severe rectal injury was observed in 0 of 13 patients (0 per cent) treated with 125iodine, 3 of 329 (1 per cent) treated with 6,400 to 6,800 rad external irradiation, 2 of 39 (5 per cent) treated with 7,000 to 7,300 rad external irradiation, and 1 of 7 (14 per cent) treated with 198gold and external irradiation. The impact of radiation dose, radiation therapy technique and surgical trauma was assessed. Rectal injury was managed by supportive measures in 2 patients and by diverting colostomy in 3 with benefit. One patient underwent abdominoperineal resection. A small bowel fistula and an intra-abdominal abscess developed, and the patient died.

1984-04-01

168

Medicinal protection with Chinese herb-compound against radiation damage  

Energy Technology Data Exchange (ETDEWEB)

Experiments were carried out on mice and the subjects irradiated for cancer therapy to evaluate the protective efficacy of a Chinese medicinal herb-compound (CMHC). The lethality and the degree of leucopenia caused by radiation in mice medicated with CMHC were significantly less in comparison with control mice (p less than 0.01 and p less than 0.001, respectively). CMHC significantly improved the WBC and the thrombocytes in irradiated workers (p less than 0.01 and p less than 0.001, respectively). The WBC count of 40 patients under radiotherapy while treated with CMHC recovered from 3450 +/- 77/c.mm to 5425 +/- 264/c.mm (p less than 0.001); whereas, in the control group, without any medication, the WBC count dropped significantly (p less than 0.001). Our results revealed the applicabilities of CMHC in protection against radiation damage in spaceflight and in other fields.

1990-08-01

169

Acute myelogenous leukemia following chemotherapy and radiation for rectal cancer  

Energy Technology Data Exchange (ETDEWEB)

In August 1982, a 44-year-old man was diagnosed as having rectal cancer, histologically diagnosed as well differentiated adenocarcinoma, and abdominoperineal resection and colostomy were performed. Postoperatively, he received chemotherapy with mitomycin C up to a total dose of 100 mg. In September 1986, lung metastasis occurred and he was treated with a combination chemotherapy consisting of cisplatin, pirarubicin and 5-fluorouracil. In the following year, radiation treatment (total: 6900 rad) was given for a recurrent pelvic lesion. Peripheral blood on April 30, 1988, showed anemia, thrombocytopenia and appearance of myeloblasts, and a diagnosis of acute myelogenous leukemia (FAB: M1) was made. Combination chemotherapy (including aclarubicin, vincristine, behenoyl ara-C, daunorubicin, 6-mercaptopurine, cytarabine, etoposide and prednisolone) failed to induce remission and the patient died in June 1988. This case was thought to be one of secondary leukemia ...

1989-03-01

170

The review of radioactive waste management in the world  

International Nuclear Information System (INIS)

Radioactive waste is generally classified on the basis of how much radiation and the type of radiation it emits as well as the length of time over which it will continue to emit radiation. Many activities dealing with radioactive materials produce nuclear wastes, including civilian nuclear power programs (nuclear Power plant operations and nuclear fuel-cycle activities), defense nuclear programs (nuclear weapons production, naval nuclear reactor programs, and related R and D), and industrial and institutional activities (scientific research, medical operations, and other industrial uses of Radioisotopic sources or Radio chemicals). To minimize the potential adverse health and environment impacts to people and other systems including of animals, plant and etc, during the entire lifetime of the radionuclides involved, nuclear waste must be carefully and properly ...

171

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by ...

2007-03-15

172

Multi-modality treatment of primary nonresectable intrahepatic cholangiocarcinoma with "1"3"1I anti-CEA--a Radiation Therapy Oncology Group Study  

International Nuclear Information System (INIS)

Thirty-seven patients with primary nonresectable intrahepatic cholangiocarcinoma (57% with prior treatment and/or metastasis) were prospectively treated with external radiation, chemotherapy, and "1"3"1I labelled anti-CEA. Therapy began in all trials with whole liver irradiation (21.0 Gy, 3.0 Gy/Fx, 4 days/week, 10 MV photons) with alternate treatment day chemotherapy (Adriamycin, 15 mg + 5-FU, 500 mg). One month after external beam therapy, chemotherapy was given (Adriamycin, 15 mg + 5-FU, 500 mg) followed the next day by the first administration of "1"3"1I anti-CEA. The treatment schedule used was 20 mCi day 0; 10 mCi day 5 as an outpatient. This schedule was derived from tumor dose estimates which indicated that 20 mCi (8-10 mCi/mg IgG) was sufficient to achieve tumor saturation with a tumor effective half-life of 3 to 5 days, depending upon the species of animal from which the antibody was obtained. The median tumor ...

173

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...

2007-07-01

174

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...

2007-05-10

175

FY1999 Meeting of The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan. Thermal simulation I; 1999 nendo gakujutsu koenkai gaiyo. Onnetsu simulation 1  

Energy Technology Data Exchange (ETDEWEB)

E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood controlled region, to ...

1999-12-05

176

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their ...

1995-12-31

177

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing ...

1995-10-01

178

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

International Nuclear Information System (INIS)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their ...

1995-10-01

179

Radiation hardening of diagnostics  

International Nuclear Information System (INIS)

The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing ...

180

Overview of US LMFBR Structural Materials Mechanical Properties Program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.

1983-01-01

181

Overview of U.S. LMFBR structural materials mechanical properties program  

International Nuclear Information System (INIS)

This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).

1983-10-10

182

Fundamental R and D program on water chemistry of supercritical pressure water under radiation field  

International Nuclear Information System (INIS)

In a supercritical water-cooled reactor, property of water changes significantly around the critical point. It is expected that irradiation and change of water property will affect the chemistry and material corrosion. Deep understanding of interactions between supercritical water and materials under irradiation is important. However, comprehensive data on radiolysis, kinetics, corrosion and thermodynamics have not been obtained due to the severe experimental condition. To get such data by experiments and computer simulations, a national program funded by Ministry of Education, Culture, Sports, Science and Technology (MEXT) has been started since December 2002. (author)

2003-09-15

183

Parameterization of GCM subgrid nonprecipitating cumulus and stratocumulus clouds using stochastic/phenomenological methods. Annual technical progress report, 1 December 1992--30 November 1993  

Energy Technology Data Exchange (ETDEWEB)

This document is a progress report to the USDOE Atmospheric Radiation and Measurement Program (ARM). The overall project goal is to relate subgrid-cumulus-cloud formation, coverage, and population characteristics to statistical properties of surface-layer air, which in turn are modulated by heterogeneous land-usage within GCM-grid-box-size regions. The motivation is to improve the understanding and prediction of climate change by more accurately describing radiative and cloud processes.

1993-08-27

184

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

185

Tracheal compression by mediastinal masses in children: CT evaluation  

Energy Technology Data Exchange (ETDEWEB)

Chest computed tomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.

1983-10-01

186

Cutaneous and subcutaneous Ewing's sarcoma: an indolent disease  

International Nuclear Information System (INIS)

Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy of the mass at the time of referral. They were enrolled on ...

2000-01-15

187

Yttrium Y 90 Ibritumomab Tiuxetan, Fludarabine, Radiation Therapy, and Donor Stem Cell Transplant in Treating Patients With Relapsed or Refractory Non-Hodgkin's Lymphoma  

Science.gov (United States)

B-cell Chronic Lymphocytic Leukemia; Nodal Marginal Zone B-cell Lymphoma; Recurrent Adult Burkitt Lymphoma; Recurrent Adult Diffuse Large Cell Lymphoma; Recurrent Adult Diffuse Mixed Cell Lymphoma; Recurrent Adult Diffuse Small Cleaved Cell Lymphoma; Recurrent Adult Grade III Lymphomatoid Granulomatosis; Recurrent Adult Immunoblastic Large Cell Lymphoma; Recurrent Adult Lymphoblastic Lymphoma; Recurrent Grade 1 Follicular Lymphoma; Recurrent Grade 2 Follicular Lymphoma; Recurrent Grade 3 Follicular Lymphoma; Recurrent Mantle Cell Lymphoma; Recurrent Marginal Zone Lymphoma; Recurrent Small Lymphocytic Lymphoma; Splenic Marginal Zone Lymphoma; Waldenstrom Macroglobulinemia

2010-10-12

188

Treatment of hepatocellular carcinoma (HCC) with radiolabeled Lipiodol: a preliminary report  

Energy Technology Data Exchange (ETDEWEB)

Fatty acid esters such as Lipiodol or Ethiodol are known to selectively localize in vascular hepatocellular carcinomas (HCC), following intraarterial hepatic administration. Lipiodol was labeled with radioactive /sup 131/I and administered in 47 patients with HCC for both imaging and therapy. The short term preliminary results suggest radiolabeled Lipiodol is effective in eliminating ascites, shrinking the tumor by a high internal radiation dose, and in improving symptomatology of these tumors. In the future, /sup 90/Y, which is a stronger pure beta-emitter (maximum beta energy of 2.27 MeV, a half life of 64 h, and a maximum penetration or beta range of 11mm), than /sup 131/I will be used for more effective treatment of HCC.

1987-12-01

189

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...

2011-01-01

190

Thyroid cancer stem cells  

British Library Electronic Table of Contents (United Kingdom)

Thyroid cancer is the most frequently diagnosed endocrine cancer and causes more deaths than all other endocrine cancers combined. Research findings support the concept that a subpopulation of thyroid cancer cells displays properties characteristic of stem cells. These putative cancer-forming entities drive tumorigenesis as a result of their dual ability to undergo self-renewal and to differentiate into various types of cancer cells; they also mediate metastasis and are resistant to the effects of chemotherapy and radiation therapy. This Review discusses the cellular origin of thyroid cancer and the properties of the thyroid cancer stem cell niche. The article critically evaluates the methods used to identify molecular markers expressed by thyroid-cancer-initiating cells and outlines prosp...

2011-01-01

191

High-dose radiation therapy for inoperable non-small cell lung cancer without mediastinal involvement (clinical stage N0, N1)  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of radiation therapy alternative to surgery for clinical N0-N1 non-small cell lung cancer (NSCLC). From 1976 through 1989, 116 patients with NSCLC without mediastinal involvement were treated with definitive radiation therapy alone at Gunma University Hospital. All patients were treated with once-daily standard fractionation using 10 MV X-rays. The total dose ranged from 60 Gy to 80 Gy. The actuarial 2- and 5-year survival rates of the entire group were 43% and 20%, respectively with a median survival time of 19 months. The survival of 76 patients with stage T2 tumors was significantly better than that of 28 patients with T3 tumors (mean survival time 21 versus 15.5 months; p<0.05). Sixty-two patients with tumors less than 5 cm in diameter had a 2-year progression rate of 20%, in comparison with 39% of 54 patients with tumors greater than 5 cm. The difference of survivals ...

1996-09-01

192

Electromagnetic fields - introduction to relevant issues  

International Nuclear Information System (INIS)

This introductory paper surveys potential sources of electric magnetic, and electro-magnetic fields. Various cases are discussed to exemplify the total frequency range: nuclear magnetic resonance tomography, high-voltage transmission lines, transformer stations, effect lighting balls, military transmitters, transmitter towers of the Postal Services and other operators, mobile radiotelephone equipment, large broadcasting transmitters, radar radiation, high-frequency heat therapy. There is evidence suggesting that electric, magnetic and electro-magnetic fields may possibly represent a certain nuisance or health hazard even at field strength occuring in equipment used for every-day-life purposes, with an emphasis on their possible actions and effects in children and adolescents. The author discusses, in conclusion, the aerial equipment ordinance issued by Lower Saxony. (Uhe).

1993-06-01

193

Adaptive Radiation Therapy for Localized Mesothelioma with Mediastinal Metastasis Using Helical Tomotherapy  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...

2009-01-01

194

Adaptive Management of Liver Cancer Radiotherapy  

British Library Electronic Table of Contents (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...

2010-01-01

195

A new method in the management of skin neoplasm using a flexible radioactive patch  

Energy Technology Data Exchange (ETDEWEB)

We have developed a flexible radioactive polyurethane patch incorporating {beta}-emitting radionuclide (166Ho) to treat malignant skin lesions. We covered the tumor surface (n=133) with the radioactive patch for 33.58 {+-} 5.33 minutes. Radiation dose delivered was 35 Gy for Bowen's disease (n=78), Kaposi sarcoma (n=25), actinic keratosis (n=5), and 50 Gy for BCC (n=17) and squamous carcinoma (n=8). Complete response was observed in 91.7% after the first therapeutic trial, 96.2% after 2nd and 97.7% after 4th trial with excellent cosmetic outcome for 31.15{+-}13.88 months of follow-up. Radioactive patch therapy is effective for superficial skin cancers that are impractical for surgery.

2005-07-01

196

Health, Safety, and Environment Division: Annual progress report 1987  

Energy Technology Data Exchange (ETDEWEB)

The primary responsibility of the Health, Safety, and Environment (HSE) Division at the Los Alamos National Laboratory is to provide comprehensive occupational health and safety programs, waste processing, and environment protection. These activities are designed to protect the worker, the public, and the environment. Many disciplines are required to meet the responsibilities, including radiation protection, industrial hygiene, safety, occupational medicine, environmental science, epidemiology, and waste management. New and challenging health and safety problems arise occasionally from the diverse research and development work of the Laboratory. Research programs in HSE Division often stem from these applied needs. These programs continue but are also extended, as needed to study specific problems for the Department of Energy and to help develop better occupational health and safety practices.

1988-04-01

197

Reconnaissance radiological characterization for the White Point Nike Missile Site, San Pedro, California  

International Nuclear Information System (INIS)

This report is the result of field work performed at the former White Point Nike Missile Site, San Pedro, California. The Hazardous Waste Remedial Actions Program tasked the Oak Ridge National Laboratory Pollutant Assessments Group in Grand Junction, Colo., with this project. The objective was to determine whether or not radioisotopes possibly associated with past Department of Defense (DOD) operations were present and within accepted background levels. The radiation survey was accomplished by performing three independent radiation surveys, both outdoors and indoors, and random soil sampling. Initially, the site was land surveyed to develop a grid block system. A background radiation investigation was performed out in the San Pedro area.

198

Radiation therapy for gastrointestinal lymphomas: indications and techniques  

International Nuclear Information System (INIS)

Gastrointestinal lymphomas are almost exclusively of a non Hodgkin's type. The Western form is characterized by a higher incidence of stomach location (50 %), a MALT type (mucosa associated lymphoid tissue) (40 %), a B-cell type (90 %), and a high grade (55 %). Chronic infection with Helicobacter pylori is an important risk factor. Mediterranean lymphomas form a particular clinical and pathological entity with diffuse involvement of the small bowel and are frequently being associated with a chronic malabsorption disorder. Eradication of Helicobacter pylori in early lymphomas, and the use of tetracyclines in early Mediterranean lymphomas, have been shown to induce durable remissions. For more advanced gastric lymphomas, treatment usually consists of anthracycline-based chemotherapy followed by involved field radiotherapy. Surgery is usually reserved for complications such as perforation or bleeding, or in some selected cases for salvage after failure of non-surgical ...

199

System 80+trademark Standard Design: CESSAR design certification  

International Nuclear Information System (INIS)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80"+trademark Standard Design. This volume 11 discusses Radiation Protection, Conduct of Operations, and the Initial Test Program.

200

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

201

IAEA Co-ordinated Research Program (CRP)  

International Nuclear Information System (INIS)

The Coordinated Research Project is a topical collection of research agreements and contracts. The research contracts are awarded with financial support of about 10-20% of the total contract cost. Among the activities of the project is the organization of consultant group meetings and workshops involving several international experts and representatives of users and developers of border radiation monitoring equipment. The project also supports in coordinating the development of equipment and techniques for up-to-date border monitoring and in establishing of a process for providing nuclear forensics support to member states

2010-05-19

202

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

203

Study on the stability of the Maytenus aquifolium Martius chemical components submitted to ionizing radiation (X-ray and #gamma#)  

International Nuclear Information System (INIS)

The interest for medicinal plants has raised again in the last decades, after overcoming a declination period caused by the advances in the researches and development of the synthetic drugs industries. This growing interest has been stimulated mainly by searching cheap and accessible alternative therapies. However, in order to have natural products based treatment in an efficient and safety way, it is necessary to guarantee the plant authenticity, finding adulterations and to assure a low level of microbiological contaminations to avoid damages to consumer's health. The decontamination method should be chosen for eliminating or reduce the microorganisms level without loss of the plant active constituents that would destroy its therapeutic action. At the present work, the possibility of using #gamma# and X electromagnetic radiations to sterilize a Brazilian medicinal plant (Maytenus aquifolium Martius, Celastraceae), which shows anti-ulcer ...

204

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were ...

2010-07-01

205

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy  

International Nuclear Information System (INIS)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were ...

2010-08-18

206

Advances in beam physics and technology: Colliders of the future  

International Nuclear Information System (INIS)

Beams may be viewed as directed and focussed flow of energy and information, carried by particles and electromagnetic radiation fields (ie, photons). Often, they interact with each other (eg, in high energy colliders) or with other forms of matter (eg, in fixed targets, sychrotron radiation, neutron scattering, laser chemistry/physics, medical therapy, etc.). The whole art and science of beams revolve around the fundamental quest for, and ultimate implementation of, mechanisms of production, storage, control and observation of beams -- always directed towards studies of the basic structures and processes of the natural world and various practical applications. Tremendous progress has been made in all aspects of beam physics and technology in the last decades -- nonlinear dynamics, superconducting magnets and rf cavities, beam instrumentation and control, novel concepts and collider praradigms, to name a few. We illustrate ...

1994-11-14

207

A comparison study for dose calculation in radiation therapy: pencil beam Kernel based vs. Monte Carlo simulation vs. measurements  

International Nuclear Information System (INIS)

Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. Home-made inhomogeneous phantom, Helax-TMS ver. 6.0 and Monte ...

2002-10-20

208

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...

1991-01-01

209

The Argonne boundary layer experiments facility : using minisodars to complement a wind profiler network.  

Energy Technology Data Exchange (ETDEWEB)

The Argonne Boundary Layer Experiments (ABLE) facility, located in south central Kansas, east of Wichita, is devoted primarily to investigations of and within the planetary boundary layer (PBL), including the dynamics of the mixed layer during both day and night; effects of varying land use and land form; the interactive role of precipitation, runoff, and soil moisture; storm development; and energy budgets on scales of 10 to 100 km. Located entirely within the Walnut River watershed, ABLE provides intense measurements within the northeast quadrant (Fig. 1) of the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) of the Atmospheric Radiation Measurement (ARM) Program (Stokes and Schwarz, 1994). By combining the continuous measurements of ABLE with ancillary continuous measurements of, for example, the ARM and the Global Energy Water cycle Experiment (GEWEX) (Kinster and Shukla, 1990) ...

1998-06-05

210

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

211

Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)  

Energy Technology Data Exchange (ETDEWEB)

The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure ...

2006-01-17

212

Improved primary water chemistry control of PWR plant in Japan  

International Nuclear Information System (INIS)

Elevated pH operation to the pH value of 7.3 at 285degC is known to be effective for the reduction of radiation source in the primary water system of PWRs. A research project was started in 1989 and concluded in 1996 to study and verify the optimum pH and/or Li concentration from the viewpoint of radiation source reduction and materials integrity under improved water chemistry. This research project is sponsored by the Ministry of International Trade and Industries (MITI) in Japan and has two programs; high pH and high Li. The high Li program was conducted to establish the optimum Li concentration for the high boron concentration region (1100 - 1800 ppm) of the high burn up operation. In this paper, we shall discuss radiation source behavior under high pH conditions and PWSCC (Primary Water Stress Corrosion Cracking) susceptibility of materials with change of primary water chemistry ...

1998-04-01

213

Role of radiation therapy in the management of nonmetastatic Ewing's sarcoma of bone. Report of the intergroup Ewing's sarcoma study  

International Nuclear Information System (INIS)

The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in ...

214

Radiation therapy in the multimodal management of Ewing's sarcoma of bone: report of the Intergroup Ewing's Sarcoma Study  

International Nuclear Information System (INIS)

This paper is a progress report on the role of radiation therapy (RT) in local tumor control and the decreased incidence of pulmonary metastasis in 251 patients entered in the Intergroup Ewing's Sarcoma Study. All were followed for more that 1 year, and their RT records were reviewed. Doses to the primary tumor in the range of 4,500--6,500 rad were administered over approximately 5 to 6 weeks in combination with 4 drugs, i.e., vincristine (VCR), dactinomycin (DAC), cyclophosphamide (CY), and adriamycin, or only the first 3. One group of patients received the 3 drugs and bilateral pulmonary irradiation (approximately 1,500 rad in 2 wk). Preliminary analysis showed a local primary tumor control of approximately 90%. Patients with lesions in the pelvis and humerus had local failure rates of 13% (7 of 54) and 21.4% (6 of 28), respectively. The treatment groups differed significantly in the incidence of pulmonary metastasis. Patients treated with ...

215

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the interinstitutional ...

2007-06-01

216

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

International Nuclear Information System (INIS)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT investigations were planned to ...

2005-03-01

217

Biokinetic and dosimetric studies of {sup 188}Re-hyaluronic acid: a new radiopharmaceutical for treatment of hepatocellular carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and ...

2009-08-15

218

Sandia National Laboratories/California site environmental report for 1997  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of SNL/California`s ...

1998-06-01

219

Relevance of circulating nucleosomes and oncological biomarkers for predicting response to transarterial chemoembolization therapy in liver cancer patients  

UK PubMed Central (United Kingdom)

BackgroundTransarterial chemoembolization (TACE) therapy is an effective locoregional treatment in hepatocellular cancer (HCC) patients. For early modification of therapy, markers...Full Text Available

220

Efficacy of antimicrobial therapy in experimental rat pneumonia: effects of impaired phagocytosis.  

UK PubMed Central (United Kingdom)

The importance of intact host defense mechanisms for successful antimicrobial therapy was investigated in an animal model. Recovery from lobar pneumococcal pneumonia as a result of penicillin therapy...Full Text Available

1979-07-01

221

Application of rhenium-188 HEDP in bone metastases therapy  

International Nuclear Information System (INIS)

Radionuclide bone metastases therapy is a major achievement of nuclear medicine. Development of less radiotoxic and more effective radiopharmaceuticals is therefore a challenge for radiopharmacists and industry. This paper reviews the application of rhenium-188 HEDP as a reactor- or generator-produced nuclide for bone metastases therapy. (author)

222

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, ...

1997-01-05

223

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, ...

1996-09-01

224

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section ...

2002-12-01

225

Recent Therapy for Reversible Airway Disease  

UK PubMed Central (United Kingdom)

The current therapy for extrinsic and intrinsic asthma, together with that of ‘wheezing bronchitis’, is presented, with special attention to bronchodilators and adrenocorticosteroids....Full Text Available

1976-03-01

226

Gene therapy for ocular diseases  

UK PubMed Central (United Kingdom)

The eye is an easily accessible, highly compartmentalised and immune-privileged organ that offers unique advantages as a gene therapy target. Significant advancements have been made in understanding...Full Text Available

2011-05-01

227

EFFECT OF ANATOMIC MOTION ON PROTON THERAPY DOSE DISTRIBUTIONS IN PROSTATE CANCER TREATMENT  

UK PubMed Central (United Kingdom)

PurposeTo determine the dosimetric impact of inter-fraction anatomical movements in prostate cancer patients receiving proton therapy.Full Text Available

2007-02-01

228

Digoxin therapy  

UK PubMed Central (United Kingdom)

1 Recommendations for correct therapy with digoxin from twenty-five sources are reviewed. 2 Some recommendations may be unsuitable for use with high bioavailability...Full Text Available

1976-08-01

229

Surgical adjuvant therapy in colon carcinoma: a human tumor spheroid model for evaluating radiation sensitizing agents  

International Nuclear Information System (INIS)

HT-29 human colon tumor cells growing as spheroids have been evaluated as a model system for measuring the response of human colon tumor cell to antineoplastic agents. HT-29 cells have been capacity to form spheroids up to 1 mm or more in diameter when grown in spinner culture. The multicellular HT-29 spheroids develop hypoxic centers reflecting the cellular conditions found in human cancer treatment, i.e., nutritionally deficient hypoxic cells that are felt to be a significant source of both radiation and chemotherapy clinical treatment failures. Spheroids of increasing size were radiated and then dispersed into single cells for colony survival assay. Compared with irradiated single cell suspensions, the spheroid cells demonstrated a significant increase in radioresistance. Growing spheroids developed a complex radiation survival curve which was variable with respect to size of the spheroid. The drug 5-Fu was studied to ...

230

Radiotherapy in Ewing's sarcoma and PNET of the chest wall: results of the trials CESS 81, CESS 86 and EICESS 92  

International Nuclear Information System (INIS)

Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk to relapse locally ...

1998-12-01

231

The radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature  

International Nuclear Information System (INIS)

Generally, neutron, ion and electron Irradiations cause a substantial amount of hardening and significantly alter the deformation behavior of metals and alloys at relatively low irradiation temperatures. A radiation hardening is caused by the formation of microstructural defects such as dislocation loops, voids and precipitates under irradiation. Therefore, it is important to have a better knowledge of the irradiation induced microstructural defects under irradiation condition. As a part of the National mid- and long-term atomic energy R and D program, we are dealing with the radiation hardening behavior in Fe-Cr binary alloy. Fe-Cr binary alloy is a base alloy of Ferritic/Martensitic steel(F/M steel) planning to use for the Gen IV nuclear system. In this work, we investigated the radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature using ...

2009-05-01

232

A multidisciplinary study investigating radiotherapy in Ewing's sarcoma: end results of POG no. 8346  

International Nuclear Information System (INIS)

Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event-free survival (EFS), and overall survival rates from multidisciplinary therapy in Ewing's sarcoma. Methods and Materials: Between 1983 and 1988, 184 children with Ewing's sarcoma were enrolled onto Pediatric Oncology Group 8346 (POG 8346). A total of 178 (97%) met eligibility criteria; 6 had pathology other than Ewing's sarcoma. Induction chemotherapy of cyclophosphamide/doxorubicin (adriamycin )(C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy and C/A, dactinomycin, and vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. Forty patients were randomized to ...

1998-08-01

233

EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion interactions studies, ...

1996-10-01

234

Turn-key Raman lidar for profiling atmospheric water vapor, clouds, and aerosols at the US Southern Great Plains Climate Study Site  

Energy Technology Data Exchange (ETDEWEB)

There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for particle phase studies.

1997-12-31

235

Network simulation method applied to radiation and viscous dissipation effects on MHD unsteady free convection over vertical porous plate  

British Library Electronic Table of Contents (United Kingdom)

The effects of thermal radiation and viscous dissipation on magneto-hydrodynamic (MHD) unsteady free-convection flow over a semi-infinite vertical porous plate are analysed. The fluid considered is non-gray (absorption coefficient dependent on wave length). The Network Simulation Method is used to solve the boundary-layer equations based on the finite-difference formulation; only discretization of the spatial co-ordinates is necessary, while time remains as a real continuous variable. This method provides a solution for both transient and steady-state problems at the same time, and programming does not require manipulation of the sophisticated mathematical software that is inherent in other numerical methods. The velocity, temperature, local skin-friction and local Nusselt number are studi...

2007-01-01

236

Mammary carcinogenesis in the rat after low-dose irradiation  

International Nuclear Information System (INIS)

Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated irradiations with gamma-rays. (author). 8 refs., 3 figs.

1992-07-12

237

Calculation of the view factors for radiant heat exchange in a new volumetric receiver with tapered ducts  

Energy Technology Data Exchange (ETDEWEB)

The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.

1995-02-01

244

Aquatic Therapy  

Science.gov (United States)

... use of water in wound management, such as whirlpool baths, but can be used interchangeably with the ...

245

Alternative Technologies for Medical Radionuclide Production  

International Science & Technology Center (ISTC)

Creation of Economic Alternative Technologies for Radionuclide Production for Medical Diagnostics and Therapy

246

Geodynamic program office  

Energy Technology Data Exchange (ETDEWEB)

Program activities and achievements in 1982 of the geodynamic program are summarized. The significant results presented are summarized.

1983-05-01

247

Neutron cross section measurements using the Oak Ridge electron linear accelerator  

Energy Technology Data Exchange (ETDEWEB)

During this reporting period, the work supported under DOE Grant No. FG02-87ER40326.A003 has resulted in one publication, two papers submitted to Phys. Rev. C for publication, and one paper presented at a professional meeting. During this period, modifications were made to the interactive R-Matrix fitting computer program DSIG to include the total radiation widths in the R-Matrix calculation of the cross section. The R-Matrix analyses of n+{sup 90}Zr and n+{sup 208}Pn have already begun.

1990-08-01

248

Mathematical child phantom for the calculation of dose to the organs at risk  

Energy Technology Data Exchange (ETDEWEB)

In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.

1988-05-01

249

Laboratory robotics systems at the Savannah River Laboratory  

International Nuclear Information System (INIS)

Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given.

1983-11-16

250

Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities  

Energy Technology Data Exchange (ETDEWEB)

The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.

1999-01-01

251

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, the authors are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. They are actively developing improved DC iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. They are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. They are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1988-03-01

252

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, we are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. We are actively developing improved dc iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. We are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. We are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1987-01-01

253

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

254

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, ...

1981-11-01

255

Stochastic versus deterministic kernel-based superposition approaches for dose calculation of intensity-modulated arcs  

International Nuclear Information System (INIS)

Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were subsequently interpolated into finer angular intervals for dose ...

2008-09-07

256

Simulation for position determination of distal and proximal edges for SOBP irradiation in hadron therapy by using the maximum likelihood estimation method  

Energy Technology Data Exchange (ETDEWEB)

In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the whole target volume. Therefore, in the ...

2005-12-21

257

Clinical utility of serum ferritin levels in patients with malignant tumors treated by radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The serum levels of ferritin in 394 patients, including 339 patients with various malignant tumors and 23 with various non-malignant diseases, and 32 healthy subjects were determined. The normal levels of ferritin were 82.7 +- 42.3 ng/ml for males and 42.0 +- 36.9 ng/ml for females. The positive ratio of serum ferritin level was 28% in patients with malignant tumors and 22% in patients with non-malignant diseases. The usefulness of serum ferritin assay in screening for malignant tumors appeared to be limited. High serum levels of ferritin were found in patients with malignant lymphoma (positive ratio: 42%), pulmonary cancer (38%) and esophageal cancer (37%). According to the histological types, epidermoid cancer appeared to produce a higher serum level of ferritin than adenocarcinoma in patients with pulmonary cancer. It was interesting that malignant lymphoma had a high serum level of ferritin in spite of its low serum level of CEA. Carcinoma of the digestive tracts except for ...

1983-10-01

258

Educating College Students with Disabilities: What Academic & Fieldwork Educators Need To Know.  

Science.gov (United States)

This book is designed to provide occupational therapist and occupational therapists and assistant educators with information on the rights of higher education students with disabilities and the rights of the occupational therapy profession to uphold its standards. Chapter 1, "Legal Foundations," provides an overview of federal law, implementing regulations, and student and faculty rights and responsibilities. Chapter 2, "Investigating Existing Institutional Resources and Establishing Linkages," discusses required campus access services, campus support structures, compliance officers, and student advocacy groups. The following chapter, "Technical Standards and Essential Requirements," addresses qualified students, technical standards determination, and essential program requirements. Chapter 4, "Auxiliary Aids, Academic Adjustments, and Reasonable Accommodations," discusses test-taking accommodations, waiving course requirements, tape ...

1996-12-01

259

A Blueprint for Telerehabilitation Guidelines?October 2010  

British Library Electronic Table of Contents (United Kingdom)

Committee Members Co-Chairs David Brennan, M.B.E., Senior Research Engineer, National Rehabilitation Hospital, Washington, District of Columbia. Lyn Tindall, Ph.D., Speech-Language Pathologist, Department of Veterans Affairs Medical Center, Lexington, Kentucky. Writing Committee Janet Brown, M.A., CCC-SLP, Director, Health Care Services, American Speech-Language-Hearing Association, Rockville, Maryland. Mike Campbell, M.S., M.B.A., CCC-SLP, Director of the Speech and Hearing Program, The University of North Carolina at Greensboro, Browns Summit, North Carolina. Jana Cason, D.H.S., OTR/L, Assistant Professor, Auerbach School of Occupational Therapy, Louisville, Kentucky. Diana Christiana, M.A.T., CCC-SLP, President/CEO, Clinical Communications, Sugar Land, TX. Alan Lee, Ph.D., P.T., D.P.T.,...

2011-01-01

260

Radiosurgery for metastatic brain tumors  

International Nuclear Information System (INIS)

Stereotactic radiosurgery (SRS) precisely delivers high-dose radiation to a small target (usually less than 3-4 cm in diameter), in a single session with steep dose-fall, employing various radiation methods. SRS provides good tumor control for small brain metastases from various primary cancers, with minimal untoward effects on surrounding normal brain. This excellent tumor control prevents neurological death and maintains good activity of daily life. Although surgery with whole-brain radiation therapy (WBRT) remains an important option for patients with a solitary brain metastasis, SRS with or without WBRT should be considered in patients with a limited number of small tumors and a good prognosis. Many reports, as well as both retrospective and prospective reviews, have shown WBRT before or after SRS to improve local control and reduce new distant lesion emergence. However, upfront WBRT does not ...

2009-08-01

261

Punica granatum peel extract protects against ionizing radiation-induced enteritis and leukocyte apoptosis in rats  

International Nuclear Information System (INIS)

Radiation-induced enteritis is a well-recognized sequel of therapeutic irradiation. Therefore we examined the radioprotective properties of Punica granatum peel extract (PPE) on the oxidative damage in the ileum. Rats were exposed to a single whole-body X-ray irradiation of 800 cGy. Irradiated rats were pretreated orally with saline or PPE (50 mg/kg/day) for 10 days before irradiation and the following 10 days, while control rats received saline or PPE but no irradiation. Then plasma and ileum samples were obtained. Irradiation caused a decrease in glutathione and total antioxidant capacity, which was accompanied by increases in malondialdehyde levels, myeloperoxidase activity, collagen content of the tissue with a concomitant increase 8-hydroxy-2'-deoxyguanosine (an index of oxidative DNA damage). Similarly, pro-inflammatory cytokines (TNF-?, IL-1? and IL-6) and lactate dehydrogenase were elevated in irradiated groups as compared to control. PPE treatment reversed ...

2009-07-01

262

Irradiation with and without razoxane in the treatment of incompletely resected or inoperable recurrent rectal cancer. Results of a small randomized multicenter study  

Energy Technology Data Exchange (ETDEWEB)

Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, ...

2007-07-15

263

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

264

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. ...

2011-01-01

265

Physics of electron beam therapy  

International Nuclear Information System (INIS)

A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...

266

Management of Ewing's sarcoma  

International Nuclear Information System (INIS)

Forty cases of Ewing's sarcoma of various sites had attended the Department of Radiotherapy at the Wanless Hospital and the Miraj Medical Centre, attached to the Government Medical College, Miraj, Maharashtra, from January, 1970 through December, 1979. There were 28 male patients and 12 female patients in the series with a male to female ratio of 2.3:1. The youngest patient in the series was a female of 6 years of age with the tumour in the scapula and the oldest patient was a 32-year-old male with a lesion in the metacarpal bone. Sixty per cent of the cases were seen in the second decade. The average age of the patients was 13.5 years. The bones of the lower extremities were most commonly involved with the highest number (35 per cent) of the cases occurring in the femur. Involvement of the bones of the right side of the body was almost equal to that of the left side. Swelling over the site of the lesion and pain over the swelling were the most common complaints noted in all the cases. ...

267

Irradiating the groin nodes without breaking a leg: A comparison of techniques for groin node irradiation  

International Nuclear Information System (INIS)

The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, the electron ...

268

Evaluation of the radioprotective effect of turmeric extract and vitamin E in mice exposed to therapeutic dose of radioiodine  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the radioprotective effect of turmeric extract (40 mg/kg body weight) and vitamin E (#alpha# - tocopherol acetate, 400 IU/kg body weight) supplementation on lipid peroxidation, reduced glutathione and antioxidant defense enzymes in various organs like liver, kidney and salivary glands at 24 h in adult Swiss mice. "1"3"1Iodine exposure significantly increased lipid peroxidation in kidney and salivary glands in comparison to control animals. Pre supplementation with turmeric extract for 15 days showed significant lowering of lipid peroxidation in kidney. On the other hand vitamin E pre supplementation showed marked reduction in lipid peroxidation in salivary glands. Reduced glutathione levels decreased significantly in liver after radiation exposure. However, pre supplementation with turmeric extract and vitamin E did not improve glutathione levels in liver. In conclusion we have observed differential radioprotective effect of ...

2008-10-01

269

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related variance contributions, ...

2008-08-01

270

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

271

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal imaging. When PACS is introduced to the ...

1992-07-01

272

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In computed radiography, image processing (tone scale modification and edge enhancement) is possible, and is advantageous portal imaging. When PACS is introduced to the ...

1992-01-01

273

US Department of Energy Nuclear Energy University program in robotics for advanced reactors: Program plan, FY 1987-1991  

International Nuclear Information System (INIS)

The US Department of Energy has provided support to four universities and the Oak Ridge National Laboratory in order to pursue research leading to the development and deployment of an advanced robotic system capable of performing tasks that are hazardous to humans, that generate significant occupational radiation exposure, and/or whose execution times can be reduced if performed by an automated system. The goal is to develop a generation of advanced robotic systems capable of performing surveillance, maintenance, and repair tasks in nuclear facilities and other hazardous environments. This goal will be achieved through a team effort among the Universities of Florida, Michigan, Tennessee, Texas, and the Oak Ridge National Laboratory, and their industrial partners, Combustion Engineering, Martin Marietta Baltimore Aerospace, Odetics, Remotec, and Telerobotics International. Each of the universities and ORNL have ongoing activities and corresponding facilities in ...

274

Overview of the FRG waste package materials corrosion test program  

International Nuclear Information System (INIS)

Presently in the FRG there are essentially three institutions involved in corrosion experiments related to high level waste package materials, namely KfK-INE, Nukem and Bayer Leverkusen. In 1981 KfK-INE started a corrosion test program aiming at the selection of suitable canister materials for vitrified high level waste. The program encompassed electrochemical investigations, which were concluded in 1984. Moreover field corrosion tests and laboratory experiments were initiated, and are still ongoing. Several possible canister materials such as mild steel, Ti-Pd-alloy, Hastelloy C4 and others were investigated under the influence of varying parameters such as temperature, and radiation. Both Nukem Company and DWK were assigned the responsibility to conceive and develop a cask for the direct final disposal of spent fuel assemblies. Two solution turned out as most promising for corrosion protection of final disposal casks: (1) ...

1988-03-08

275

Geothermal materials program: strategy. Final report  

Energy Technology Data Exchange (ETDEWEB)

The following topics are discussed: program goal and objectives, program organization, and program status. Current program projects are described. (MHR)

1980-10-01

276

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

277

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

278
279

Remote Sensing and In-Situ Observations of Arctic Mixed-Phase and Cirrus Clouds Acquired During Mixed-Phase Arctic Cloud Experiment: Atmospheric Radiation Measurement Uninhabited Aerospace Vehicle Participation  

Energy Technology Data Exchange (ETDEWEB)

The Atmospheric Radiation Monitor (ARM) uninhabited aerospace vehicle (UAV) program aims to develop measurement techniques and instruments suitable for a new class of high altitude, long endurance UAVs while supporting the climate community with valuable data sets. Using the Scaled Composites Proteus aircraft, ARM UAV participated in Mixed-Phase Arctic Cloud Experiment (M-PACE), obtaining unique data to help understand the interaction of clouds with solar and infrared radiation. Many measurements obtained using the Proteus were coincident with in-situ observations made by the UND Citation. Data from M-PACE are needed to understand interactions between clouds, the atmosphere and ocean in the Arctic, critical interactions given large-scale models suggest enhanced warming compared to lower latitudes is occurring.

2005-03-18

280

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the ...

2009-10-15

281

Limiting values of radionuclide intake and air concentration and dose conversion factors for inhalation, submersion, and ingestion: Federal guidance report No. 11  

Energy Technology Data Exchange (ETDEWEB)

Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived guides that are ...

1988-09-01

282

Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns  

Energy Technology Data Exchange (ETDEWEB)

Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar capability, lack of bone-induced artifacts, and high-contrast resolution, is likely to reveal subependymal spread ...

1997-01-01

283

Can intensity-modulated radiation therapy of the paraaortic region overcome the problems of critical organ tolerance?  

Energy Technology Data Exchange (ETDEWEB)

Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT investigations were ...

2005-03-01

284

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, ...

1997-02-01

285

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...

286

Calculated doses from inhaled transuranium radionuclides and potential risk equivalence to whole-body radiation  

International Nuclear Information System (INIS)

The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles within the respirable size range, a useful description is ...

1975-11-17

287

Apoptotic pathways as regulators of recombination  

International Nuclear Information System (INIS)

Apoptosis, or programmed cell death (PCD), is a fundamental process that protects organismal integrity. In earlier work, we demonstrated that over-expression of either of two anti-apoptotic members of the BCL-2 family (BCL-2 or BCL-X L could elevate the frequency of radiation-induced mutations at the autosomal TK1 locus in human TK6 lymphoblasts that express wild-type TP53. Ectopic expression of BCL-X L also elevated the frequencies of double-strand break-induced gene conversion. The purpose of this study is to determine if BCL-2 family proteins promote radiation mutagenesis indirectly through their suppression of PCD, or whether the 'pro-mutagenic' function of these proteins can be separated from their anti-apoptotic function. We developed stable transfectants of TK6 cells that express a mutated form of BCL-X L with a single amino acid substitution in the BH1 domain that is known to interfere with the ability to suppress ...

2003-08-17

288

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method; Analise das radiacoes neutron e gama acopladas, aplicada a blindagem com varias camadas pelo metodo multigrupo do albedo  

Energy Technology Data Exchange (ETDEWEB)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the ...

2002-07-01

289

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method  

International Nuclear Information System (INIS)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the ...

2002-01-01

290

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its accuracy of calculations at low energies ...

2001-03-01

291

Suicide of EMT-6 tumor cells by decays from radioactively-labelled sensitizer adducts  

International Nuclear Information System (INIS)

Nitroaromatic radiosensitizers become metabolically bound preferentially to hypoxic cells and at least 10/sup 9/ adducts/cell can be tolerated as non-toxic. EMT-6 tumor cells have been incubated in hypoxia in the presence of /sup 3/H-Misonidazole and /sup 125/I-Azomycin Riboside for various times and the amount of /sup 3/H or /sup 125/I bound/cell was determined. Cells were stored as monolayers at 25"0C for up to 96 hr to accumulate radioactive decays and transferred at various times to 37"0C for colony-forming assays. No radiation inactivation was measured in cells which had incorporated at least 10/sup 6/ /sup 3/H or 10/sup 5/ /sup 125/I atoms. Previous studies had shown that -- 1% of MISO adducts to EMT-6 cells was associated with cellular DNA. These data indicate that the radiation-induced damage produced by these quantities of bound /sup 3/H or /sup 125/I causes little or not cell inactivation. The results of current studies to measure the ...

292

Study of proton therapy on malignant tumors. Effects in twenty-four hours after proton irradiation  

Energy Technology Data Exchange (ETDEWEB)

We irradiated proton beams on the ears of rabbits and the Harding-Passey mouse melanoma and observed their morphological change. We used 52 MeV proton beams from the INS-FM cyclotron. We adjusted the energy of the proton beams to be at the plateau part of the Bragg curve, at the half-way point of the Bragg peak, and at the Bragg peak. The amount of radiation was 5000rad in each case. The Harding-Passey mouse melanoma was transplanted into the subcutan of a three week old mouse. In this experiment, we used tumors, the diameter of which grew up to 1.5-2cm in 2-3 weeks after the transplantation. Using the jroscope, we observed both lightly and severely damaged cells. Using proton irradiation with the Bragg peak located at depth of 1mm in the rabbit's ears, we studied the change in the tissue. Irradiated epidermis fell off and was eroded because of radiation damage, but the rear surface of the rabbit's ears was only slightly ...

1983-01-01

293

Impact of more intensive written information in patients having radical radiation therapy: Results of a prospective randomized phase III trial  

International Nuclear Information System (INIS)

Background and purpose: A diagnosis of malignancy and its treatment is a very stressful time for patients and their families. This study was conducted to determine the impact of more intensive written information on patients' anxiety levels. The secondary aim was to determine the impact of this information on patients' satisfaction levels. Materials and methods: This prospective randomized trial consisted of patients with a pathological diagnosis of cancer having radical radiotherapy (RT). Patients were randomized to receive the more intensive information (including written information and a telephone call from the research nurse) or not to receive the more intensive information at the time of their initial consultation with the radiation oncologist. Study questionnaires measuring anxiety (STAI form) were completed prior to their first consultation (baseline) at the time of simulation (pre-RT) and at the completion of radiotherapy. A second questionnaire assessing ...

2010-08-01

294

A multi-disciplinary study investigating radiotherapy in Ewing's sarcoma - a final report of POG 8346  

International Nuclear Information System (INIS)

Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event free (EFS) and overall survival rates from multi-disciplinary therapy in Ewing's Sarcoma (ES). Materials and Methods: Between 1983 and 1988, 184 children with ES were enrolled onto POG 8346. 178 (97%) met eligibility criteria; 6 had non-ES pathology. Induction treatment of Cyclophosphamide/Adriamycin (C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy (XRT) and C/A, Dactinomycin and Vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. 40 patients were randomized to receive SF, whole bone XRT to 39.6 Gy plus a 16.2 Gy boost (total 55.8 Gy) or IF to 55.8 Gy while ...

295

Proposal of a system of signalling of security in occupational radiological protection for radiactives and nuclear installations  

International Nuclear Information System (INIS)

After five years of implantation of a program for classification and signalling of restricted areas in the IPEN-CNEN-SP, we noticed that the applied measures of radio protection contributed for the improvement of the system of occupational radiological protection, promoting an improvement in the security of the workers, towards the planning in the execution of the activities involving the use of sources of ionizing radiation. Later, during the implantation of this program, the service of occupational radiological protection, there was great difficulty to conciliate its necessities in terms of security signalling, face the absence of existing standardisation in the country for the minimum disposals on the subject in question. Nowadays there are different interpretations of the specific criteria and many effective normative documents that exist in the country. This work presents as proposal the elaboration of a technical ...

296

Investigations of excretion rates of the radionuclides {sup 230}Th, {sup 226}Ra, {sup 210}Pb and {sup 210}Po of persons of the general population and of workers in selected regions in Germany  

Energy Technology Data Exchange (ETDEWEB)

According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the incorporation of ...

2006-07-01

297

p53 Regulates Oxidative Stress-Mediated Retrograde Signaling: A Novel Mechanism for Chemotherapy-Induced Cardiac Injury  

UK PubMed Central (United Kingdom)

The side effects of cancer therapy on normal tissues limit the success of therapy. Generation of reactive oxygen species (ROS) has been implicated for numerous chemotherapeutic agents including doxorubicin...Full Text Available

298

The Influence of Abacavir and Other Antiretroviral Agents on Virologic Response to Hepatitis C Virus Therapy Among Antiretroviral-Treated HIV-Infected Patients  

UK PubMed Central (United Kingdom)

BackgroundIt remains unclear if certain antiretroviral medications, particularly abacavir, compromise response to hepatitis C virus (HCV) therapy. Such data can inform...Full Text Available

2010-01-01

299

Survival of HIV-Infected Adolescents on Antiretroviral Therapy in Uganda: Findings from a Nationally Representative Cohort in Uganda  

UK PubMed Central (United Kingdom)

BackgroundAdolescents have been identified as a high-risk group for poor adherence to and defaulting from combination antiretroviral therapy (cART) care. However, data on outcomes...Full Text Available

300

Simulation of electron beam therapy employing cone collimation  

Energy Technology Data Exchange (ETDEWEB)

A simple device is described which is used to determine treatment distance and beam direction in electron therapy employing one collimation. A technique for the production of irregular field templates and localization films is given.

1983-07-01

301

Self-management of fatigue in rheumatoid arthritis: a randomised controlled trial of group cognitive-behavioural therapy  

UK PubMed Central (United Kingdom)

ObjectivesTo investigate the effect of group cognitive behavioural therapy (CBT) for fatigue self-management, compared with groups receiving fatigue information alone, on fatigue...Full Text Available

302

Relation between regional and global systolic function in patients with ischemic cardiomyopathy after ?-Blocker therapy or revascularization  

UK PubMed Central (United Kingdom)

BackgroundTo assess the relationship between improved regional and global myocardial function in patients with ischemic cardiomyopathy in response to β-blocker therapy or...Full Text Available

303

Real-Time Adherence Monitoring for HIV Antiretroviral Therapy  

UK PubMed Central (United Kingdom)

Current adherence assessments typically detect missed doses long after they occur. Real-time, wireless monitoring strategies for antiretroviral therapy may provide novel opportunities to proactively...Full Text Available

2010-12-01

304

Predictive and prognostic markers for epidermal growth factor receptor inhibitor therapy in non-small cell lung cancer  

UK PubMed Central (United Kingdom)

Epidermal growth factor receptor (EGFR) related therapies – mainly tyrosine kinase inhibitors (TKIs) such as erlotinib and gefitinib, but also monoclonal antibodies targeting EGFR, for example,...Full Text Available

2009-11-01

305

Novel therapies for resistant focal segmental glomerulosclerosis (FONT) phase II clinical trial: study design  

UK PubMed Central (United Kingdom)

BackgroundThe lack of adequate randomized clinical trials (RCT) has hindered identification of new therapies that are safe and effective for patients with primary focal segmental...Full Text Available

306

Metal stenting to resolve post-photodynamic therapy stricture in early esophageal cancer  

UK PubMed Central (United Kingdom)

Photodynamic therapy (PDT) is an established endoscopic technique for ablating Barrett’s esophagus with high-grade dysplasia or early-stage intraepithelial neoplasia. The most common clinically...Full Text Available

2011-03-14

307

Measuring the efficacy of anti-malarial drugs in vivo: quantitative PCR measurement of parasite clearance  

UK PubMed Central (United Kingdom)

BackgroundArtemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries,...Full Text Available

308

Macrophage-directed immunotherapy as adjuvant to photodynamic therapy of cancer.  

UK PubMed Central (United Kingdom)

The effect of Photofrin-based photodynamic therapy (PDT) and adjuvant treatment with serum vitamin D3-binding protein-derived macrophage-activating factor (DBPMAF) was examined using a mouse SCCVII...Full Text Available

1997-01-01

309

Long-term impact of acyclovir suppressive therapy on genital and plasma HIV RNA in Tanzanian women: a randomised controlled trial  

UK PubMed Central (United Kingdom)

BackgroundHerpes simplex virus (HSV) suppressive therapy reduces genital and plasma HIV-1 RNA over periods up to three months but the longer-term effect is unknown.Full Text Available

2010-05-01

310

Induced pluripotent stem cells, new tools for drug discovery and new hope for stem cell therapies  

UK PubMed Central (United Kingdom)

Somatic cell nuclear transfer or therapeutic cloning has provided great hope for stem cell-based therapies. However therapeutic cloning has been experiencing both ethical and technical difficulties....Full Text Available

2009-01-01

311

Impact of concomitant use of DMARDs on the persistence with anti-TNF therapies in patients with rheumatoid arthritis: results from the British Society for Rheumatology Biologics Register  

UK PubMed Central (United Kingdom)

ObjectiveTo evaluate the effect of different concomitant disease modifying antirheumatic drugs (DMARDs) on the persistence with antitumour necrosis factor (anti-TNF) therapies in...Full Text Available

312

Immune activation and IL-12 production during acute/early HIV infection in the absence and presence of highly active, antiretroviral therapy  

UK PubMed Central (United Kingdom)

Suppressed IL-12 production and maladaptive immune activation, both of which are ameliorated by successful highly active antiretroviral therapy (HAART), are thought to play important roles in the immunopathogenesis...Full Text Available

2008-12-01

313

Fracture risk associated with continuation versus discontinuation of bisphosphonates after 5 years of therapy in patients with primary osteoporosis: a systematic review and meta-analysis  

UK PubMed Central (United Kingdom)

Purpose:The risks and benefits of continuing bisphosphonate therapy beyond 5 years in patients with primary osteoporosis have not been well established.Methods:We...Full Text Available

2011-01-01

314

First line targeted therapies in breast cancer: focus on bevacizumab  

UK PubMed Central (United Kingdom)

The heterogeneity of metastatic breast cancer mandates the need to select therapies taking into account tumor and patient characteristics. Chemotherapy is indicated in the palliative setting especially...Full Text Available

2007-03-01

315

Effectiveness of Manual Physical Therapy for Painful Shoulder Conditions: A Systematic Review  

UK PubMed Central (United Kingdom)

Multiple disease-specific systematic reviews on the effectiveness of physical therapy intervention for shoulder dysfunction have been inconclusive. To date, there have been two systematic reviews that...Full Text Available

2009-01-01

316

Delivered dose of renal replacement therapy and mortality in critically ill patients with acute kidney injury  

UK PubMed Central (United Kingdom)

IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available

2009-01-01

317

Comprehensive Approach to Arthroscopic Rotator Cuff Repair: Options and Techniques  

Medline Plus

... and at that point she had already failed physical therapy, which someone else had prescribed, and so ... MRI, we may try a brief course of physical therapy to see if they feel better, but ...

318

Combined photodynamic therapy and intravitreal bevacizumab for idiopathic polypoidal choroidal vasculopathy: one-year follow-up  

UK PubMed Central (United Kingdom)

ObjectiveTo report the efficacy and safety of combined photodynamic therapy (PDT) and intravitreal bevacizumab (IVB) injection in the treatment of idiopathic polypoidal choroidal...Full Text Available

2010-01-01

319

Clinical review: Patency of the circuit in continuous renal replacement therapy  

UK PubMed Central (United Kingdom)

Premature circuit clotting is a major problem in daily practice of continuous renal replacement therapy (CRRT), increasing blood loss, workload, and costs. Early clotting is related to bioincompatibility,...Full Text Available

2007-01-01

320

Clinical Efficacy of Self-applied Blue Light Therapy for Mild-to-Moderate Facial Acne  

UK PubMed Central (United Kingdom)

This study was an evaluation of the performance of self-applied, blue light, light-emitting diode therapy in the treatment of mild-to-moderate inflammatory acne on the face, concerning: 1) time to improvement...Full Text Available

2009-03-01

321

Approaches to enhancing the quality of drug therapy. A joint statement by the CMA and the Canadian Pharmaceutical Association. Canadian Medical Association.  

UK PubMed Central (United Kingdom)

This joint statement was developed by the CMA and the Canadian Pharmaceutical Association, a national association of pharmacists, and includes the goal of drug therapy, strategies for collaboration...Full Text Available

1996-09-15

322

Antioxidant Treatment Alters Peripheral Vascular Dysfunction Induced by Postnatal Glucocorticoid Therapy in Rats  

UK PubMed Central (United Kingdom)

BackgroundPostnatal glucocorticoid therapy in premature infants diminishes chronic lung disease, but it also increases the risk of hypertension in adulthood. Since glucocorticoid...Full Text Available

323

A tool to balance benefit and harm when deciding about adjuvant therapy  

UK PubMed Central (United Kingdom)

Adjuvant therapy aims to prevent outgrowth of residual disease but can induce serious side effects. Weighing conflicting treatment effects and communicating this information with patients is not elementary....Full Text Available

2009-03-24

325

Quality assurance requirements in a clinical heavy ion therapy unit  

International Nuclear Information System (INIS)

German 2006 [1 p.] Germany Karger, Christian Heeg, Peter Jaekel, Oliver

2006-03-13

326

Femoral neck fracture after irradiation therapy  

International Nuclear Information System (INIS)

Japanese Mar 1999 p. 371-372 Japan Shi, Dequan Yamazaki, Takashi

1999-03-01

327

Chromosomal damage in human lymphocytes from radio-isotope therapy  

International Nuclear Information System (INIS)

(Dec 1973). United Kingdom Stevenson, AC Medical Research Council, Oxford

328

DARPA Program Composition for Embedded Systems (PCES) ...  

Science.gov (United States)

... Title : DARPA Program Composition for Embedded Systems (PCES) Program Capstone Demonstration Video (Postprint) (CD-ROM). ...

2005-09-01

329

Electron accelerator unit for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

1987-01-27

330

Electron accelerator unit for electron beam therapy  

International Nuclear Information System (INIS)

An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.

331

Calculated fluence spectra at neutron therapy facilities  

International Nuclear Information System (INIS)

The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).

1995-11-13

332

Anesthetics and electroconvulsive therapy seizure duration: implications for therapy from a rat model.  

Science.gov (United States)

The anesthetic agents methohexital (Brevital), Innovar, and ketamine (Ketaject) were examined for their effect on seizure duration following electroconvulsive stimulation in a rat model of electroconvulsive therapy (ECT). Compared to unanesthetized control animals, methohexital anesthesia shortened seizure duration by 42%, ketamine anesthesia tended to increase seizure duration, and Innovar anesthesia had no effect on duration of seizures. PMID:7349626

1981-12-01

333

Geothermal Technologies Program: News  

Science.gov (United States)

and Renewable Energy EERE Home | Programs & Offices | Consumer Information Geothermal Technologies Program Search Search Help Geothermal Technologies Program HOME ABOUT...

2011-08-21

335

EERE: Geothermal Technologies Program Home Page  

Science.gov (United States)

and Renewable Energy EERE Home | Programs & Offices | Consumer Information Geothermal Technologies Program Search Search Help Geothermal Technologies Program HOME ABOUT...

2011-08-21

336

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a ...

337

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone ...

2007-05-01

338

The Need for Confirmatory Experiments on the Radioactive Source Term from Potential Sabotage of Spent Nuclear Fuel Casks  

Science.gov (United States)

A technical review is presented of experiment activities and state of knowledge on air-borne, radiation source terms resulting from explosive sabotage attacks on spent reactor fuel subassemblies in shielded casks. Current assumptions about the behavior of irradiated fuel are largely based on a limited number of experimental results involving unirradiated, depleted uranium dioxide ''surrogate'' fuel. The behavior of irradiated nuclear fuel subjected to explosive conditions could be different from the behavior of the surrogate fuel, depending on the assumptions made by the evaluator. Available data indicate that these potential differences could result in errors, and possible orders-of-magnitude overestimates of aerosol dispersion and potential health effects from sabotage attacks. Furthermore, it is suggested that the current assumptions used in arriving at existing regulations for the transportation and storage of spent fuel in ...

2002-04-01

339

Technology development, evaluation, and application (TDEA) FY 1997 progress report  

Energy Technology Data Exchange (ETDEWEB)

The public expects that the Los Alamos National Laboratory (LANL) will operate in a manner that prevents negative impacts to the environment and protects the safety and health of its employees and the public. To achieve this goal within budget, the Department of Energy (DOE) and LANL must develop new and improved environment, safety, and health (ES and H) technologies and implement innovative, more cost-effective ES and H approaches to operations. In FY95, the Environment, Safety, and Health (ESH) Division initiated a Technology Development, Evaluation, and Application (TDEA) program. The purpose of this unique program is to test and develop technologies that solve LANL ES and H problems and improve the safety of LANL operations. This progress report presents the results of 10 projects funded in FY97 by the TDEA Committee of the Environment, Safety, and Health Division. Products generated from the projects funded in FY97 included implementation ...

1998-05-01

340

Progress at LAMPF, 1992--1993  

Energy Technology Data Exchange (ETDEWEB)

This Progress Report describes the operation of the Los Alamos Meson Physics Facility (LAMPF) and the research programs carried out there for the years 1992 and 1993. The accelerator operated for over 100 days in 1992, providing beams of H{sup +}, H{sup {minus}}, and polarized H{sup {minus}} for a rich and varied research program in nuclear physics. The accelerator had only fair beam availability in 1992 (for example, the average H{sup +} beam availability was 72%), caused largely by problems in the 201-MHz rf system. A major effort was expended to address these problems before the 1993 run. These efforts were rewarded by good beam availability in 1993 and few problems with the 201-MHz system. LAMPF operated remarkably smoothly during 1993, in the midst of a period of great uncertainty in the future of the facility and the downsizing of MP Division, which led to the loss of a large number of key people to positions elsewhere in the Laboratory. ...

1994-07-25

341

Programmed improvements of the alternating gradient synchrotron complex at Brookhaven National Laboratory, Upton, New York. Environmental assessment  

Energy Technology Data Exchange (ETDEWEB)

The purpose and need for DOE to undertake the actions described in this document are to improve the efficiency of the Alternating Gradient Synchrotron (AGS) complex. Benefits would include optimization of the AGS scientific program, increased high-energy and nuclear physics experimentation, improved health and safety conditions for workers and users, reduced impact on the environment and the general public, energy conservation, decreased generation of hazardous and radioactive wastes, and completion of actions required to permit the AGS to be the injector to the Relativistic Heavy Ion Collider (RHIC)., Improved efficiency is defined as increasing the AGS`s capabilities to capture and accelerate the proton intensity transferred to the AGS from the AGS booster. Improved capture of beam intensity would reduce the beam losses which equate to lost scientific opportunity for study and increased potential for radiation doses to workers and the general ...

1994-03-01

342

Physics through the 1990s: scientific interfaces and technological applications  

Energy Technology Data Exchange (ETDEWEB)

The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics--biophysics, the brain, and theoretical biology; the physics-chemistry interface--instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics--tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics--complex systems and applications in basic research; mathematics--field theory and chaos; microelectronics--integrated circuits, miniaturization, future trends; optical information technologies--fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security--devices, weapons, and arms control; medical physics--radiology, ultrasonics, NMR, and photonics. An executive summary and many chapters contain recommendations regarding funding, ...

1986-01-01

343

Experimental Seminar on Nuclear Energy for Teachers  

Energy Technology Data Exchange (ETDEWEB)

`Experimental Seminar on Nuclear Energy for Teachers` was conducted and sponsored by the Science and Technology Agency. And in order to understand nuclear energy properly through lectures and experiments with good results inclass, the seminar carried out for teachers of high schools and junior high schools by the Nuclear Technology and Education Center (NuTEC), Japan Atomic Energy Research Institute in 1990 FY to 1997 FY. In this report, details of the seminars in the above period are described and No.1 to 17 of Communication Letters of Experimental Seminar on Nuclear Energy` started at 1992 FY are described also. These letters were prepared for attendant follow-up program. And programs of recent seminars, future`s seminars, impressions and comments from attendants, reports from actual classes and others are described in these letters and they are very useful for educational classes on nuclear energy by other teachers. Therefore contents of the ...

1999-02-01

344

Evaluating Parameterizations in General Circulation Models: Climate Simulation Meets Weather Prediction  

Energy Technology Data Exchange (ETDEWEB)

To significantly improve the simulation of climate by general circulation models (GCMs), systematic errors in representations of relevant processes must first be identified, and then reduced. This endeavor demands that the GCM parameterizations of unresolved processes, in particular, should be tested over a wide range of time scales, not just in climate simulations. Thus, a numerical weather prediction (NWP) methodology for evaluating model parameterizations and gaining insights into their behavior may prove useful, provided that suitable adaptations are made for implementation in climate GCMs. This method entails the generation of short-range weather forecasts by a realistically initialized climate GCM, and the application of six-hourly NWP analyses and observations of parameterized variables to evaluate these forecasts. The behavior of the parameterizations in such a weather-forecasting framework can provide insights on how these schemes might be improved, and modified ...

2004-05-06

345

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic ...

1995-12-31

346

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. ...

1986-01-01

347

Environmental Biosciences Program Third Quarter Report, Year 2  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2005-03-31

348

Environmental Biosciences Program Report for Year Three  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2006-07-31

349

Environmental Biosciences Program Report for Year 3  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2007-04-30

350

Environmental Biosciences Program Quarterly Report  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2008-01-31

351

Environmental Biosciences Program Quarterly Report  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2007-07-31

352

Environmental Biosciences Program Quarterly Report  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2006-10-31

353

Environmental Biosciences Program Fourth Quarter Report  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation s need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent ...

2005-06-30

354

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have yielded 10 mA pulses with a width of about 20 ...

1995-08-21

355

Proceedings of the workshop on radioactivity associated with coal use  

Energy Technology Data Exchange (ETDEWEB)

A workshop on radioactivity in coal use was held on September 15 through 17, 1981, under the auspices of the US Department of Energy, Office of Environmental Programs, and the Los Alamos National Laboratory. The purpose of the workshop was to identify research issues associated with radioactivity resulting from the use of coal for electric power generation. The concensus of the 10 scientists participating in the workshop was that a moderate to strong need exists for research in solubility of fly ash in different fluids and for determination of radioactivity in construction materials. Several additional research issues were identified but were given a lower priority. Summaries of each presentation are included. Titles are: some effects of coal combustion on the radiation environment; radionuclides in western coal at Mound; low-level radiation in coals utilized and ashes produced at New York State electric utilities; ...

1981-12-01

356

New neutron simulation capabilities provided by the Sandia Pulse Reactor (SPR-III) and the Upgraded Annular Core Pulse Reactor (ACPR)  

Science.gov (United States)

The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which enhances the neutron exposure capabilities over those of the former ACPR Facility.

1978-07-01

357

University of Michigan workscope for 1991 DOE University program in robotics for advanced reactors  

International Nuclear Information System (INIS)

The University of Michigan (UM) is a member of a team of researchers, including the universities of Florida, Texas, and Tennessee, along with Oak Ridge National Laboratory, developing robotic for hazardous environments. The goal of this research is to develop the intelligent and capable robots which can perform useful functions in the new generation of nuclear reactors currently under development. By augmenting human capabilities through remote robotics, increased safety, functionality, and reliability can be achieved. In accordance with the established lines of research responsibilities, our primary efforts during 1991 will continue to focus on the following areas: radiation imaging; mobile robot navigation; three-dimensional vision capabilities for navigation; and machine-intelligence. This report discuss work that has been and will be done in these areas.

358

U.S. Department of Energy, Nevada Operations Office, Environmental Monitoring Program: Summary data report - first and second calendar quarters 1994  

International Nuclear Information System (INIS)

During the first and second quarters of 1994 air samples were collected and analyzed from 54 air particulate/halogen sampling stations, 10 noble gas sampling stations and 19 tritiated water vapor sampling stations. Surface water samples were collected and analyzed from 12 open water supply reservoirs, 8 natural springs, 2 wastewater containment ponds and 9 sewage lagoons. Groundwater samples were obtained brom 10 potable and 1 non-potable supply wells, and 8 drinking water consumption points. Ambient radiation levels were measured at 193 locations.

1991-10-31

359

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, ...

360

Operation of beam line facilities for real-time x-ray studies at Sector 7 of the advanced photon source. Final Report  

Energy Technology Data Exchange (ETDEWEB)

This Final Report documents the research accomplishments achieved in the first phase of operations of a new Advanced Photon Source beam line (7-ID MHATT-CAT) dedicated to real-time x-ray studies. The period covered by this report covers the establishment of a world-class facility for time-dependent x-ray studies of materials. During this period many new and innovative research programs were initiated at Sector 7 with support of this grant, most notably using a combination of ultrafast lasers and pulsed synchrotron radiation. This work initiated a new frontier of materials research: namely, the study of the dynamics of materials under extreme conditions of high intensity impulsive laser irradiation.

2003-09-10

361

Geometric configuration factors for polygonal zones using Nusselt's unit sphere  

Energy Technology Data Exchange (ETDEWEB)

The Energy Laboratory of the University of Houston has developed a computer simulation program called CREAM (Cavity Radiation Exchange Analysis Model) for application to the solar central receiver system. CREAM contains a geometric configuration factor generator based on Nusselt's method. A formulation of Nusselt's method provides the basis for a FORTRAN subroutine NUSSELT. Numerical results from NUSSELT are compared to analytic values and values from Sparrow's method. Sparrow's method is based on a double contour integral and its reduction to a single integral which is a approximated by Gaussian methods. Nusselt's method is adequate for the intended engineering applications, but Sparrow's method is an order of magnitude more efficient in many situations.

1983-05-01

362

Daytime Raman lidar measurements of water vapor during the ARM 1997 water vapor intensive observation period  

Energy Technology Data Exchange (ETDEWEB)

Because of the importance of water vapor, the ARM program initiated a series of three intensive operating periods (IOPs) at its CART (Cloud And Radiation Testbed) site. The goal of these IOPs is to improve and validate the state-of-the-art capabilities in measuring water vapor. To date, two of the planned three IOPs have occurred: the first was in September of 1996, with an emphasis on the lowest kilometer, while the second was conducted from September--October 1997 with a focus on both the upper troposphere and lowest kilometer. These IOPs provided an excellent opportunity to compare measurements from other systems with those made by the CART Raman lidar. This paper addresses primarily the daytime water vapor measurements made by the lidar system during the second of these IOPs.

1998-04-01

363

Association of area sociodemographic characteristics and capacity for treatment with disparities in colorectal cancer care and mortality  

British Library Electronic Table of Contents (United Kingdom)

AbstractBACKGROUND: Disparities in treatment and mortality for colorectal cancer (CRC) may reflect differences in access to specialized care or other characteristics of the area where an individual lives. METHODS: Surveillance, Epidemiology and End Results Program-Medicare data for seniors diagnosed with CRC were linked to area measures of the sociodemographic characteristics and the capacity of surgeons, medical oncologists, and radiation oncologists. Outcomes included receipt of stage-appropriate CRC care and mortality. RESULTS: After adjustment, blacks and Hispanics were less likely than whites to undergo surgery (odds ratio [OR] 0.57, 95% confidence interval (CI) 0.52-0.63 and OR 0.82, 95% CI 0.70-0.95, respectively). Individuals who lived in areas with the highest tertile of surgeon c...

2011-01-01

364

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

365

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

366

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen ...

2010-06-15

367

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants  

International Nuclear Information System (INIS)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values of thoracoabdominal babygrams and abdomen X-rays in DvHK could ...

2010-06-01

368

Endoscopic monitoring of infliximab therapy in Crohn's disease  

British Library Electronic Table of Contents (United Kingdom)

AbstractBackground: So far, infliximab (IFX) therapy for the treatment of Crohn's disease (CD) has generally been guided by clinical symptoms. Data on treatment response as ascertained by endoscopy in IFX therapy are scarce. The aims of this study were to measure the endoscopic response rate during IFX induction and maintenance therapy in luminal CD, and also evaluate the role of endoscopy in monitoring IFX therapy. Methods: Data obtained from 71 patients with active luminal CD and treated with IFX were analyzed retrospectively. The endoscopy findings were scored according to mucosal activity as: 0 (remission), 1-2 (mild), 3-4 (moderate), and 5-6 (severe). A positive endoscopic response was determined by a decrease in score of at least two points and mucosal healing was assigned a score of...

2011-01-01

370
371

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...

2000-12-01

372

Environmental Sciences Division annual progress report for period ending September 30, 1981  

Energy Technology Data Exchange (ETDEWEB)

Research programs from the following sections and programs are summarized: aquatic ecology, environmental resources, earth sciences, terrestrial ecology, advanced fossil energy program, toxic substances program, environmental impacts program, biomass, low-level waste research and development program, US DOE low-level waste management program, and waste isolation program.

1982-04-01

373

Coal Liquefaction Program: Fiscal year 1989, Summary program plan  

Energy Technology Data Exchange (ETDEWEB)

Program plans of the Office of Coal Technology in coal liquefaction are presented. Technology description, status, market applications, program strategy and program management descriptions are included. 2 figs. (CBS)

1989-01-01

374

A survey of monitoring and assay systems for release of metals from radiation controlled areas at LANL.  

Energy Technology Data Exchange (ETDEWEB)

At Los Alamos National Laboratory (LANL), a recent effort in waste minimization has focused on scrap metal from radiological controlled areas (RCAs). In particular, scrap metal from RCAs needs to be dispositioned in a reasonable and cost effective manner. Recycling of DOE scrap metals from RCAs is currently under a self-imposed moratorium. Since recycling is not available and reuse is difficult, often metal waste from RCAs, which could otherwise be recycled, is disposed of as low-level waste. Estimates at LANL put the cost of low-level waste disposal at $550 to $4000 per cubic meter, depending on the type of waste and the disposal site. If the waste is mixed, the cost for treatment and disposal can be as high as $50,000 per cubic meter. Disposal of scrap metal as low-level waste uses up valuable space in the low-level waste disposal areas and requires transportation to the disposal site under Department of Transportation (DOT) regulations for low-level waste. In contrast, disposal as ...

2002-01-01

375

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

376

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

378

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

380

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

381

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

382

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

383

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

384

Isotope Production at the Hanford Site in Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

This report was prepared in response to a request from the Nuclear Energy Research Advisory Committee (NERAC) subcommittee on ''Long-Term Isotope Research and Production Plans.'' The NERAC subcommittee has asked for a reply to a number of questions regarding (1) ''How well does the Department of Energy (DOE) infrastructure sme the need for commercial and medical isotopes?'' and (2) ''What should be the long-term role of the federal government in providing commercial and medical isotopes?' Our report addresses the questions raised by the NERAC subcommittee, and especially the 10 issues that were raised under the first of the above questions (see Appendix). These issues are related to the isotope products offered by the DOE Isotope Production Sites, the capabilities and condition of the facilities used to produce these products, the management of the isotope production ...

1999-06-01

385

Second malignancies after treatment for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: Some former retrospective studies have suggested that patients with Ewing's sarcoma might have a very high risk for developing secondary sarcomas if treated with radiotherapy. We have evaluated the risk of second malignancies (SM) in patients treated in the German Cooperative Ewing's Sarcoma Studies CESS 81 and CESS 86. Materials and methods: From January 1981 through June 1991, a total number of 674 patients was registered in the two multicentric Ewing's sarcoma trials CESS 81 (1981 through 1985) and CESS 86 (1986 through June 1991). The systemic treatment consisted in both studies of a four-drug-chemotherapy (VACA= vincristine, actinomycin D, cyclophosphamide and adriamycin; or VAIA= vincristine, actinomycin D, ifosfamide and adriamycin) and a total number of four courses, each lasting nine weeks, was recommended by the protocol. Local therapy was either complete surgery or surgery plus postoperative radiotherapy with 36-46Gy or definitive ...

386

Characterization of an add-on multileaf collimator for electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the ...

2008-02-21

387

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

388

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace the focal and ...

2005-09-07

389

The Results of Postoperative Radiation Therapy for Perihilar Cholangiocarcinoma  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months (range, 6 to 45 months). The 3-year overall survival and 3-year ...

2009-12-01

390

Technology of iodine-131 production and its application  

International Nuclear Information System (INIS)

Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to measure the ...

391

Response of a non-Hodgkin lymphoma to "6"0Co therapy monitored by 31P MRS in situ  

International Nuclear Information System (INIS)

High quality "3"1P MR spectra (signal to noise ratio (S/N) approximately 18, 15 min acquisition for each spectrum) were consistently obtained with surface coils over a period of 6-week RT. Both transient and steady state alterations in metabolites in response to RT were found in this case. The transient changes occurred during the first 3 hr immediately after the 3rd fractionated RT, these changes include the transient elevation of the PCr resonance, a decrease in PDE and an increase in intracellular pH. The monitoring showed that the metabolites approached steady state approximately 2 hr after the fractionated radiation intervention, suggesting that in vivo MRS can be useful for studying the dynamics of tumor response to RT such as repair of potential lethal damage, growth delay, and reoxygenation etc. The steady-state MR spectra showed the net response to each intervention and can clinically be useful for predicting and measuring the result of the fractionated ...

392

Radiotherapy and multimodality management of cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate the results of radiotherapy in cholangiocarcinoma patients managed with various combinations of chemotherapy and surgical resection with selective liver transplantation. Methods and Materials: From January 1990 to December 1995, 61 patients with histologically confirmed biliary duct adenocarcinoma were seen in the Radiation Oncology Department of the University of Pittsburgh. Median follow-up was 22 months (1 to 91 months). The extent of surgery was complete resection in 23 patients (including 17 with orthotopic liver transplant), partial resection in 4, and biopsy in 34. All patients had radiotherapy; median dose was 49.5 Gy. Thirty patients received chemotherapy: 5-fluorouracil (5-FU)-leucovorin with interferon alpha (IFN#alpha#) in 27, and taxol in 3. Results: The median survival was 20 months (95% CI 15-25 months). The 5-year actuarial survival was 23.8 #+-# 6.8%. The only significant variable in multivariate analysis was achieving a ...

1999-04-01

393

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator  

International Nuclear Information System (INIS)

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to ...

2007-05-01

394

Hyperthermia in the Treatment of Cholangiocarcinoma: Development and Testing of an Endobiliary Microwave Device  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to create, perfect and test a hyperthermia balloon catheter for local treatment of cholangiocarcinoma. The device should induce hyperthermia in tumor tissue by acting locally in the bile duct lumen in contact with the tumor-infiltrated duct wall. In addition, it should exert tissue compression to cause an appreciable reduction in tumor microvasculature flow, thus improving thermal performance. Methods: According to the design specifications, the working temperature range should allow the device to be used for hyperthermia therapy either in combination with radiation and/or chemotherapy(radio/chemo-sensitizing effect at 42-45 deg. C) or alone (induction of coagulation necrosis above 65 deg. C). The balloon serves as an anchoring system during treatment and as a functional element to induce tissue compression. In vitro mechanical evaluation of the pressure/volume relationship, with the balloon inside rigid ...

2003-08-01

395

High dose rate /sup 60/Co remote afterloading irradiation in cancer of the cervix in Haiti, 1977-1984  

Energy Technology Data Exchange (ETDEWEB)

From 1977 through 1984, 293 previously untreated patients with biopsy proven carcinoma of the uterine cervix were treated by whole pelvis irradiation and high intensity 60Co remote afterloading (RAL) intrauterine tandem techniques in Haiti. The treatment results were analyzed retrospectively to evaluate the therapeutic results and prognostic factors of a strict protocol involving 40 Gy to the whole pelvis (2 Gy/day, 5 days/week). In addition, on the 5th day of the 3rd week, the first outpatient 60Co remote afterloading intracavitary insertion, delivering 7.5 Gy to point A with each insertion, repeated 3 times by a week separation for a total of 4 times. The total TDF for external beam plus RAL was 158 and 175 for early and late effects respectively. One hundred-four patients were evaluable after 1 year or more follow-up, with a median of 26.5 months. No evidence of disease (NED) by Stage at 1 year was: Stage I of 100% (3/3), Stage II of 82% (9/11), Stage III of 80% (47/59), and Stage ...

1988-06-01

396

Four years of North American registry home parenteral nutrition outcome data and their implications for patient management  

International Nuclear Information System (INIS)

The OASIS Registry started annual collection of longitudinal data on patients on home parenteral nutrition (HPN) in 1984. This report describes outcome profiles on 1594 HPN patients in seven disease categories. Analysis showed clinical outcome was principally a reflection of the underlying diagnosis. Patients with Crohn's disease, ischemic bowel disease, motility disorders, radiation enteritis, and congenital bowel dysfunction all had a fairly long-term clinical outcome, whereas those with active cancer and acquired immunodeficiency syndrome (AIDS) had a short-term outcome. The long-term group had a 3-year survival rate of 65 to 80%, they averaged 2.6 complications requiring hospitalization per year, and 49% experienced complete rehabilitation. The short-term group had a mean survival of 6 months; they averaged 4.6 complications per year and about 15% experienced complete rehabilitation. The registry data also indicated HPN was used for 19,700 patients in 1987 with ...

397

Enhanced spectral discrimination through the exploitation of interface effects in photon dose data  

International Nuclear Information System (INIS)

The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous lung/water, the lung ...

2004-02-01

398

Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator  

International Nuclear Information System (INIS)

The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by evaluating correlation coefficients between the ...

2002-09-21

399

Early and Late Bowel Complication Following Irradiation of Cancer of the Uterine Cervix-Whole Pelvis External Irradiation end High-Dose-Rate Interactively Irradiation  

International Nuclear Information System (INIS)

Cervix cancer is the most common female cancer in Korea. In spite of their relatively local invasive tendency, still 44% of patient will develop recurrent cancer This result suggests that more aggressive local treatment may increase the cure rate but increased complication risk also cannot be avoidable. Various institutions proposed different treatment regimen, but recommended dose were about 4500 cGy for whole pelvis and 8000 cGy at point A, even though they agreed that those doses may not be satisfactory for control of bulky disease. 96 cases of invasive cervical cancer, treated with postoperative or primary radiation therapy were analyzed to determine the complication rate and prognostic factor in our treatment regimen which is 500-1000 cGy higher than other institution. Mean follow up duration was 21 months. Symptomatic patients including mild but persistent abdominal discomfort was 46%, but only 1 patient (1%) had operative treatment ...

1989-06-01

400

Continuous intensity map optimization (CIMO): A novel approach to leaf sequencing in step and shoot IMRT  

International Nuclear Information System (INIS)

A new leaf-sequencing approach has been developed that is designed to reduce the number of required beam segments for step-and-shoot intensity modulated radiation therapy (IMRT). This approach to leaf sequencing is called continuous-intensity-map-optimization (CIMO). Using a simulated annealing algorithm, CIMO seeks to minimize differences between the optimized and sequenced intensity maps. Two distinguishing features of the CIMO algorithm are (1) CIMO does not require that each optimized intensity map be clustered into discrete levels and (2) CIMO is not rule-based but rather simultaneously optimizes both the aperture shapes and weights. To test the CIMO algorithm, ten IMRT patient cases were selected (four head-and-neck, two pancreas, two prostate, one brain, and one pelvis). For each case, the optimized intensity maps were extracted from the Pinnacle"3 treatment planning system. The CIMO algorithm was applied, and the optimized aperture ...

2006-04-01

401

Concurrent and adjuvant docetaxel with three-dimensional conformal radiation therapy plus androgen deprivation for high-risk prostate cancer: Preliminary results of a multicentre phase II trial  

International Nuclear Information System (INIS)

Background and purpose: We evaluate the feasibility of concomitant and adjuvant docetaxel combined with three-dimensional conformal radiotherapy (3D-CRT) and androgen deprivation in high-risk prostate carcinomas. Methods: Fifty men with high-risk localized prostate cancer (16), locally advanced (28) or very high-risk prostate cancer (6) were included. Seventy Gy were delivered on prostate and seminal vesicles in 35 fractions, concurrently with weekly docetaxel (20 mg/m"2). Three weeks after the completion of 3D-CRT, docetaxel was given for 3 cycles (60 mg/m"2), every 3 weeks. Patients had to receive LHRH agonist during 3 years. Results: The intent to treat analysis shows that four patients out of 15 stopped prematurely the chemotherapy due to grade 3-4 acute toxicity. In the per protocol analysis, 46 patients completed a full-dose chemoradiation regimen representing 413 cycles: five patients experienced a grade 3 toxicity, and 15 patients experienced a grade 2 toxicity. With a median ...

2010-11-01

402

A case of wound intake of plutonium isotopes and 241Am in a human: application and improvement of the NCRP wound model.  

Science.gov (United States)

Plutonium isotopes (239Pu and 238Pu, and 241Am) with a total activity of 269 kBq were accidentally deposited in a puncture wound of the right index finger of a nuclear worker at the Mayak Production Association. Tissues surrounding the wound site contaminated with radionuclides were excised 4.5 h after the injury. Residual contamination within the wound amounted to 0.05% of the initial contamination. The 10-d therapy with CaNa3-diethylene triamine pentaacetate acid (CaNa3-DTPA) was performed in parallel with in vivo measurements of the wound site and daily urine bioassays. The wound intake of radionuclides was consistent with two forms of radioactive materials detected within the wound site, i.e., soluble compounds and a large fragment, which was completely removed by excision. On day 9 after the injury, the clearance rate from the wound site was 1.8 times higher than the rate predicted by the National Council on Radiation Protection and ...

2010-10-01

403

Environmental Biosciences Report for Year 3  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2007-10-31

404

Environmental Biosciences Quarterly Report  

Energy Technology Data Exchange (ETDEWEB)

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally ...

2007-01-31

405

Understanding and predicting soot generation in turbulent non-premixed jet flames.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the results of a project funded by DoD's Strategic Environmental Research and Development Program (SERDP) on the science behind development of predictive models for soot emission from gas turbine engines. Measurements of soot formation were performed in laminar flat premixed flames and turbulent non-premixed jet flames at 1 atm pressure and in turbulent liquid spray flames under representative conditions for takeoff in a gas turbine engine. The laminar flames and open jet flames used both ethylene and a prevaporized JP-8 surrogate fuel composed of n-dodecane and m-xylene. The pressurized turbulent jet flame measurements used the JP-8 surrogate fuel and compared its combustion and sooting characteristics to a world-average JP-8 fuel sample. The pressurized jet flame measurements demonstrated that the surrogate was representative of JP-8, with a somewhat higher tendency to soot formation. The premixed flame measurements revealed that ...

2010-10-01

406

The main activities and scientific collaboration possibilities at Ankara Nuclear research and training center  

International Nuclear Information System (INIS)

Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of ...

2004-10-01

407

Smith-Purcell free-electron laser  

International Nuclear Information System (INIS)

The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these projects are using permanent magnet undulators to couple the ...

1995-08-21

408

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation measurement capabilities ...

1995-11-01

409

What is a medical experiment?  

UK PubMed Central (United Kingdom)

Innovative therapy may appear to coincide with medical experimentation, raising ethical and legal issues, for instance on informed consent and institutional review. Medical treatments may be classified,...Full Text Available

1975-10-04

410

Vascular Effects of Photodynamic and Pulsed Dye Laser Therapy Protocols  

UK PubMed Central (United Kingdom)

Background and ObjectivePulsed dye laser (PDL) treatment of cutaneous vascular lesions is associated with variable and unpredictable efficacy. Thus, alternative treatment...Full Text Available

2008-11-01

411

Use of acupuncture therapy as a supplement to conventional medical treatments for acute ischaemic stroke patients in an academic medical centre in Korea  

British Library Electronic Table of Contents (United Kingdom)

Objectives: Acupuncture has served as a major complementary and alternative therapy that supplements conventional medicine and is the subject of growing public interest. This study was conducted to estimate the usage rate of acupuncture as a supplemental treatment in acute ischaemic stroke patients and to identify factors associated with the choice to use this therapy. Methods: Using the registry of stroke patients admitted to an academic medical centre in Korea, the use of acupuncture therapy was recorded and analysed, along with the patients' socio-demographic characteristics, hospital access variables, risk factors for ischaemic stroke and clinical characteristics. The data were analysed using descriptive statistics, chi-square tests and multiple logistic regression analyses. Results: O...

2011-01-01

413

Staging procedures in mycosis fungoides.  

UK PubMed Central (United Kingdom)

Mycosis fungoides (MF) in deep-seated lymph nodes, spleen or liver appears to be associated with a lack of response of the disease to topical external therapy. Fourteen patients with mycosis fungoides...Full Text Available

1975-03-01

414

Seamless Integration of Detection and Therapy for Breast ...  

Science.gov (United States)

... that were previously adopted by Zhu [20], Skala [3] and Wang [5,7,8] et al. in their respective studies on epithelial tissue. ...

2007-06-01

415

Rifampin Combination Therapy for Nonmycobacterial Infections  

UK PubMed Central (United Kingdom)

Summary: The increasing emergence of antimicrobial-resistant organisms, especially methicillin-resistant Staphylococcus aureus (MRSA), has resulted in the increased...Full Text Available

2010-01-01

416

Pseudomonas aeruginosa Virulence and Therapy: Evolving Translational Strategies  

UK PubMed Central (United Kingdom)

Structured abstractObjectiveAlthough most reviews of Pseudomonas aeruginosa therapeutics focus on antibiotics currently in use or...Full Text Available

2009-05-01

417

Principles of antibody therapy.  

UK PubMed Central (United Kingdom)

The success of monoclonal antibodies in clinical practice is dependent on good design. Finding a suitable target is the most important part as other properties of the antibody can be altered by genetic...Full Text Available

1992-12-05

418

Penile rehabilitation therapy with PDE-V inhibitors following radical prostatectomy: proceed with caution.  

Science.gov (United States)

Penile rehabilitation therapy following radical prostatectomy is a much debated topic. Erectile dysfunction is still a significant contributor to postoperative morbidity following radical prostatectomy, despite meticulous nerve-sparing technique. Secondary smooth muscle changes in the penis have been identified as the underlying causes of penile atrophy, veno-occlusive dysfunction, and fibrosis. Initial observations that intracavernous injection therapies used on a regular basis postoperatively resulted in improvements in the return of spontaneous erectile function led to the development of penile rehabilitation protocols. Chronic dosing of PDE-V inhibitors is now commonly used by urologists after radical prostatectomy. Despite the current enthusiasm of penile rehabilitation therapy, current scientific evidence with clinical trials is still limited. PMID:19255627

2009-01-25

419

Patient persistence with first-line antiglaucomatous monotherapy  

UK PubMed Central (United Kingdom)

PurposeTo identify the extent of persistence (period of time of continuous therapy with the drug prescribed) of glaucoma patients treated with prostaglandins (latanoprost, bimatoprost,...Full Text Available

2010-01-01

420

Novel Magnetic Fluids for Breast Cancer Therapy  

Science.gov (United States)

... metal-oleate complexes. At this point, this method has been reported only for iron nanoparticles [15]. We have demonstrated ...

2008-01-01

421

Multiple glomus tumours: successful treatment with electron beam irradiation  

Energy Technology Data Exchange (ETDEWEB)

A case is reported of a 23-year old male with multiple glomus tumours that showed marked involution after he had electron beam therapy. (author).

1990-11-01

422

Morphine versus Mexiletine for Treatment of Postamputation Pain  

UK PubMed Central (United Kingdom)

BackgroundStump and phantom pains are debilitating sequelae of amputations that are often resistant to treatment. The efficacy of pharmacologic therapies, including...Full Text Available

2008-08-01

423

Is sirolimus a therapeutic option for patients with progressive pulmonary lymphangioleiomyomatosis?  

UK PubMed Central (United Kingdom)

BackgroundLymphangioleiomyomatosis (LAM) is a rare lung disease characterised by progressive airflow obstruction. No effective medical treatment is available but therapy with sirolimus...Full Text Available

2011-01-01

424

Iron Therapy for Preterm Infants  

UK PubMed Central (United Kingdom)

SYNOPSISPreterm infants are at risk for both iron deficiency and iron overload. The role of iron in multiple organ functions suggests that iron supplementation is essential for...Full Text Available

2009-03-01

425

Insulin therapy in critically ill patients  

UK PubMed Central (United Kingdom)

Hyperglycemia frequently occurs with acute medical illness, especially among patients with cardiovascular disease, and has been linked to increased morbidity and mortality in critically ill patients....Full Text Available

2010-01-01

426

INJECTABLE IN SITU CROSS-LINKING HYDROGELS FOR LOCAL ANTIFUNGAL THERAPY  

UK PubMed Central (United Kingdom)

Invasive fungal infections can be devastating, particularly in immunocompromised patients, and difficult to treat with systemic drugs. Furthermore, systemic administration of those medications...Full Text Available

2010-02-01

427

Focal fits during chlorambucil therapy  

UK PubMed Central (United Kingdom)

An elderly man receiving chlorambucil for chronic lymphatic leukaemia developed focal fits. The onset and frequency were dose related. There was no evidence of metabolic disturbance or of meningeal...Full Text Available

1979-11-01

428

Evaluation of phenylpiperazines as targeting agents for neuroblastoma.  

UK PubMed Central (United Kingdom)

The potential of radiolabelled phenylpiperazines as agents for the detection and therapy of tumours of neural crest origin was evaluated by in vitro pharmacological studies with human neuroblastoma...Full Text Available

1996-09-01

429

Efficacy and adverse effects of intravenous lignocaine therapy in fibromyalgia syndrome  

UK PubMed Central (United Kingdom)

BackgroundTo investigate the effects of intravenous lignocaine infusions (IV lignocaine) in fibromyalgia.MethodsProspective study...Full Text Available

430

Current Status of Cognitive Behavioral Therapy for Adult Attention-Deficit Hyperactivity Disorder  

UK PubMed Central (United Kingdom)

SynopsisAttention-deficit / hyperactivity disorder (ADHD) is a valid and impairing psychological disorder that persists into adulthood in a majority of cases and is associated...Full Text Available

2010-09-01

431

Controlling Endemic Cholera with Oral Vaccines  

UK PubMed Central (United Kingdom)

BackgroundAlthough advances in rehydration therapy have made cholera a treatable disease with low case-fatality in settings with appropriate medical care, cholera continues...Full Text Available

2007-11-01

432

Center for Innovative Minimally Invasive Therapy (CIMIT)  

Science.gov (United States)

... have been awarded a contract from the Combating Terrorism Technology Support Office Technology Support Working Group (TSWG) of the ...

2004-10-01

433

Breast Cancer Treatment  

Medline Plus

... mammography or on ultrasound but not found on physical examination, we consider them non-palpable or not ... lot of this. We send every patient for physical therapy, no matter what type of reconstruction we ...

434

Antimony Toxicity  

UK PubMed Central (United Kingdom)

Antimony toxicity occurs either due to occupational exposure or during therapy. Occupational exposure may cause respiratory irritation, pneumoconiosis, antimony spots on the skin and gastrointestinal...Full Text Available

2010-12-01

435

A Novel Tool for the Assessment of Pain: Validation in Low Back Pain  

UK PubMed Central (United Kingdom)

BackgroundAdequate pain assessment is critical for evaluating the efficacy of analgesic treatment in clinical practice and during the development of new therapies. Yet the currently...Full Text Available

2009-04-01

436

WINPEPI updated: computer programs for epidemiologists, and their teaching potential  

UK PubMed Central (United Kingdom)

BackgroundThe WINPEPI computer programs for epidemiologists are designed for use in practice and research in the health field and as learning or teaching aids. The programs are free,...Full Text Available

437

The DARPA High-Performance Polymer Program. Volume 1. ...  

Science.gov (United States)

... IDA DOCUMENT D- 1174 THE DARPA HIGH-PERFORMANCE POLYMER PROGRAM ... The DARPA High-Performance Polymer Program, Volume I: ...

1992-09-01

438

Interactive computer programs in sequence data analysis.  

UK PubMed Central (United Kingdom)

We present interactive computer programs for the analysis of nucleic acid sequences. In order to handle these programs, minimum computer experience is sufficient. The nucleotide sequence of the human...Full Text Available

1982-01-11

439

Instructional Materials Development Program  

Science.gov (United States)

... Materials Development Program TECHNOLOGY EDUCATION INSTRUCTIONAL MATERIALS Elementary - High School ... of technology education materials through its Instructional Materials Development (IMD) program. The ...

440

Industrial Technologies Program: Chemicals  

Science.gov (United States)

Efficiency and Renewable Energy EERE Home | Programs & Offices | Consumer Information Chemicals Search Search Help Chemicals EERE » Industrial Technologies Program » Chemicals...

2011-10-01

441

CT-Expo - a novel program for dose evaluation in CT; CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT  

Energy Technology Data Exchange (ETDEWEB)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section ...

2002-12-01

442

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. ...

2001-03-01

443

Development of a computerized portal verification scheme for pelvic treatment fields  

International Nuclear Information System (INIS)

Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied to identify the ...

1996-09-01

444

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

446

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

447

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

448

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

449

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

451

Metal finishing and vacuum processes groups, Materials Fabrication Division progress report, March-May 1984  

Energy Technology Data Exchange (ETDEWEB)

Progress is reported in fabrication and coating activities being conducted for the weapons program, nuclear test program, nuclear design program, magnetic fusion program, and miscellaneous applications. (DLC)

1984-07-11

453

Executive Development Journeys The Essence of Customized Programs  

CERN Document Server

Summarizing the three main reasons why customized programs are commissioned, this book explains and explores the key aspects of successful development programs, with views from corporate sponsors, participants, faculty contributors and case studies of customised programs commissioned by 6 organizations

2010-01-01

454

Energy Management and Conservation Program: Fiscal Year 2005 Annual Report  

Wastenet

Keywords: energy, management, conservation, program, fiscal, year, 2005, annual, ...S Environmental Protection Agency Energy Management and Conservation Program ...ENVIRONMENTAL P ROTECTION AGENCY Energy Management and Conservation Program Fiscal Year 2005 Annual Report

458

HARPHRQ. A Geochemical Speciation Program Based on PHREEQE  

Energy Technology Data Exchange (ETDEWEB)

HARPHRQ is a geochemical speciation program developed at Harwell and based on the U.S. Geological Survey code Phreeqe.

1992-02-18

459

Geothermal Energy R&D Program Summary  

Energy Technology Data Exchange (ETDEWEB)

This is an internal DOE Geothermal Program planning and control document. Many of these reports were issued only in draft form.

1988-11-18

460

Energy Engineering Analysis Program (EEAP), Cornhusker ...  

Science.gov (United States)

... is to develop a systematic program of energy consumption reductions in compliance with the stated goals of the Army Facilities Energy Plan (AFEP ...

1984-03-01

461

A Program Manager's Guide for Software Cost Estimating  

Science.gov (United States)

... A PROGRAM MANAGER'S GUIDE FOR SOFTWARE COST ESTIMATING ... This thesis provides a broad view of the software cost estimating process. ...

2002-12-01

462

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

463

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...

2008-10-01

464

The dependence of radiation hardening and embrittlement on irradiation temperature  

International Nuclear Information System (INIS)

Assessments of the hardening and embrittlement of pressure vessel steels and welds as a function of neutron dose use trend curves derived from surveillance programs and accelerated irradiation data. A temperature dependent factor is incorporated for assessing vessel locations operating at different temperatures. As hardening and embrittlement arise from the sum of matrix damage and copper impurity precipitation, the influence of irradiation temperature on each process needs to be established. For irradiations performed below #approx# 300 C recent data shows that the dose-dependent growth of copper precipitates ceases at a mean diameter of about 2 nm that also corresponds to peak hardening and embrittlement by copper. For doses beyond this peak copper dose the property-dependence on irradiation temperature can be identified with that of matrix damage alone. An analysis of several experiments on plate steels, performed at differing irradiation temperatures, has ...

1994-06-20

465

Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another sliding graph permits the estimation of critical solution fission yields based upon fissile material concentration, critical vessel ...

1999-09-20

466

Research and development program on solar thermal use in the high temperature range. Forschungs- und Entwicklungsprogramm zur solarthermischen Nutzung im Hochtemperaturbereich  

Energy Technology Data Exchange (ETDEWEB)

In the context of the research project, the physical basis of the direct decoupling of highly concentrated solar radiation in materials without the detour via absorbing heat exchanger walls was examined. Also, the first chemical processes suitable for the effective long-term storage of solar energy were analysed, relevant experiments were carried out and the necessary receiver techniques for high temperature applications were provided. The principle of direct coupling was examined on fluidized beds on the one hand and on cavity receivers, on the other hand. The contribution shows the results achieved in detail. It is recorded that first processes for storing solar energy in chemical reactions were able to be examined. Alkaline earth hydroxides accommodated in ceramic honeycomb structures seem to be possible as stores for medium temperature ranges around 500deg C. Investigations on receiver structure materials are also making progress. Highly transparent, high ...

1988-03-01

467

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

468

Probability of failure in BWR reactor coolant piping: Guillotine break indirectly induced by earthquakes  

Energy Technology Data Exchange (ETDEWEB)

The requirements to design nuclear power plants for the effects of an instantaneous double-ended guillotine break (DEGB) of the reactor coolant piping have led to excessive design costs, interference with normal plant operation and maintenance, and unnecessary radiation exposure of plant maintenance personnel. This report describes an aspect of the NRC/Lawrence Livermore National laboratory-sponsored research program aimed at investigating whether the probability of DEGB in Reactor Coolant Loop Piping of nuclear power plants is acceptably small such that the requirements to design for the DEGB effects (e.g., provision of pipe whip restraints) may be removed. This study estimates the probability of indirect DEGB in Reactor Coolant piping as a consequence of seismic-induced structural failures within the containment of the GE supplied boiling water reactor at the Brunswick nuclear power plant. The median probability of indirect DEGB was estimated ...

1986-12-01

469

Metrology measurement capabilities  

Energy Technology Data Exchange (ETDEWEB)

Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...

1997-06-01

470

Materials considerations for the National Spallation Neutron Source target  

Energy Technology Data Exchange (ETDEWEB)

The National Spallation Neutron Source (NSNS), in which neutrons are generated by bombarding a liquid mercury target with 1 GeV protons, will place extraordinary demands on materials performance. The target structural material will operate in an aggressive environment, subject to intense fluxes of high energy protons, neutrons, and other particles, while exposed to liquid mercury and to water. Components that require special consideration include the Hg liquid target container and protective shroud, beam windows, support structures, moderator containers, and beam tubes. In response to these demands a materials R and D program has been developed for the NSNS that includes: selection of materials; calculations of radiation damage; irradiations, post irradiation testing, and characterization; compatibility testing and characterization; design and implementation of a plan for monitoring of materials performance in service; and materials engineering ...

1997-08-01

471

Hanford Site Environmental data for Calendar Year 1990. Surface and Columbia River  

Energy Technology Data Exchange (ETDEWEB)

Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1990 is a summary of offsite and onsite environmental monitoring data collected during 1990 by PNL`s Environmental Monitoring Program. The data summaries included in the annual report were created from individual surface and river monitoring results. This volume contains the individual results used to create ...

1992-01-01

472

Hanford Site Environmental data for Calendar Year 1990  

Energy Technology Data Exchange (ETDEWEB)

Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1990 is a summary of offsite and onsite environmental monitoring data collected during 1990 by PNL's Environmental Monitoring Program. The data summaries included in the annual report were created from individual surface and river monitoring results. This volume contains the individual results used ...

1992-01-01

473

FFTF [Fast Flux Test Facility] cesium trap design, installation, and operating experience  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400-MWt, sodium-cooled reactor located on the Hanford Site near Richland, Washington, USA. The FFTF is owned by the U.S. Department of Energy and is operated by the Westinghouse Hanford Company. The FFTF was designed to test fuels and materials for use in liquid metal reactors. Since initial operation in 1982, anticipated breaches of experimental fuel pins have released fission products, including cesium, into the primary sodium. Because of its high volatility, cesium vaporizes into the cover gas space, where it condenses on components and equipment and is transported into the cover gas outlet. Because of the long half-life of "1"3"7Cs, these deposits result in long-term, local radiation levels that make contact maintenance difficult. Thus, a cesium trap was installed in FFTF to reduce the cesium level in the sodium. The trap could also permit a Run Beyond Cladding Breach (RBCB) program without ...

1988-10-17

474

Development of a generic analysis code of dynamic compartment model for evaluation of doses in terrestrial biosphere  

International Nuclear Information System (INIS)

The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for dynamic compartment model (GACOM) is developed for the nuclide migration and the evaluation of doses in terrestrial biosphere. ...

1999-02-01

475

Array coil probe: Final report  

Energy Technology Data Exchange (ETDEWEB)

Nuclear steam generator tubes have become flawed in ways that challenge conventional eddy current probes. In response to the shortcomings of conventional probes, array probes have been developed to improve measurement capabilities. However, the commercially available array probes have exhibited several weaknesses that offset the advantages and limit the applications in steam generator inspections. A primary weakness is the relatively high rate of probe failure coupled with the high unit cost for each probe. This can be costly for a utility in the time lost for probe replacement and increased radiation exposure in addition to the probe costs. Other weaknesses which make array probes undesirable for routine use are: poor mechanical and electrical characteristics; difficulty in operation and calibration; and incomplete coverage of the tube circumference. Several prototype array probes have been built to address the weaknesses of the commercially available array ...

1987-03-01

476

An investigation of the production of thin films of some materials which undergo phase transitions for optical applications  

CERN Document Server

The aim of this work was to study the possibility of producing a fast switching optical thin film device to react to laser radiation in the visible/near infrared region of the spectrum. The switching mechanism was to be thermally driven. A computer program was written to enable the effects of changes of the refractive index of a component of a multilayer thin film stack to be modelled. Attempts to use the phase transition in vanadium dioxide were unsuccessful because, in the spectral region of interest, the 'open-state' absorption was too great. A class of materials known as 'the bronzes' was identified as being potentially useful. Attempts were made to produce thin films of bronze compounds of vanadium, tungsten and molybdenum by the techniques of conventional thermal evaporation and laser ablation for further studies. The former technique appeared to suffer from problems of decomposition of the source material. The latter technique showed ...

1995-01-01

477

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood  

International Nuclear Information System (INIS)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting germ cell tumors ...

2001-09-01

478

A microcontroller-based data-acquisition system for meteorological station monitoring  

International Nuclear Information System (INIS)

This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We ...

2008-12-01

479

The effect of a sports chiropractic manual therapy intervention on the prevention of back pain, hamstring and lower limb injuries in semi-elite Australian Rules footballers: a randomized controlled trial  

UK PubMed Central (United Kingdom)

BackgroundHamstring injuries are the most common injury in Australian Rules football. It was the aims to investigate whether a sports chiropractic manual therapy intervention protocol...Full Text Available

480

Syncope as a probable side effect to combination antiretroviral therapy initiated during primary HIV-1 infection  

DEFF Research Database (Denmark)

A previously healthy young man experienced several episodes of syncope while being treated with tenofovir, emtricitabine and nevirapine initiated during primary HIV-1 infection. Symptoms disappeared after discontinuation of antiretroviral therapy and we suggest that syncope may be a side effect to one of the three antiretroviral drugs that has not been described previously.

2008-01-01

481

Proton beam therapy control system  

Energy Technology Data Exchange (ETDEWEB)

A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.

2010-09-21

482

Prevention and management of osteoporosis: consensus statements from the Scientific Advisory Board of the Osteoporosis Society of Canada. 3. Effects of ovarian hormone therapy on skeletal and extraskeletal tissues in women.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To present recent evidence on the use of ovarian hormone therapy (OHT) for osteoporosis and outline safe and effective regimens. OPTIONS: Estrogen alone, estrogen and progestins, progestins...Full Text Available

1996-10-01

483

New insights in LV torsion for the selection of cardiac resynchronisation therapy candidates  

British Library Electronic Table of Contents (United Kingdom)

Recent literature indicates that torsion of the left ventricle (LV) is a promising predictor for response to cardiac resynchronisation therapy (CRT). Among patients with severe heart failure, 45 to 75% of patients show rigid body rotation, where the base and apex rotate in the same direction, instead of normal, opposite rotation. The occurrence of this phenomenon seems to be a good indicator for response to CRT. From this review, it can be concluded that LV torsion might be a welcome addition to current selection criteria.

2011-01-01

484

Maggot Therapy Takes Us Back to the Future of Wound Care: New and Improved Maggot Therapy for the 21st Century  

UK PubMed Central (United Kingdom)

In the 21st century, eighty years after William Baer presented his groundbreaking work treating bone and soft tissue infections with live maggots, thousands of therapists around the globe have rediscovered...Full Text Available

485

Improved Mobilization of the CD34+ and CD133+ Bone Marrow-Derived Circulating Progenitor Cells by Freshly Isolated Intracoronary Bone Marrow Cell Transplantation in Patients with Ischemic Heart Disease  

UK PubMed Central (United Kingdom)

Cell therapy is a promising novel option for treatment of cardiovascular disease. Because the role of bone marrow-derived circulating progenitor cells (BM-CPCs) after cell therapy is less clear, we...Full Text Available

2011-09-01

486

Acute myelomonocytic leukemia after irradiation and chemotherapy for Ewing's sarcoma  

International Nuclear Information System (INIS)

A case is presented in which the diagnosis of acute myelomonocytic leukemia was made 16 months after the start of irradation and chemotherapy for Ewing's sarcoma. The association of these two diseases is rare. The etiologic role of therapy in the development of leukemia is speculative in this case. However, there is need for surveillance for secondary neoplasms of all types so that the benefits of therapy may be properly weighed against the risks.

487

Sprengel deformity in a nine-year-old boy: diagnosis and therapy; Sprengel-Deformitaet bei einem neunjaehrigen Jungen: Diagnostik und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Sprengel deformity is a congential malformation with usually unilateral elevation and medial rotation of the scapula. An omovertebral bone is generally present. Associated skeletal malformations are frequently present. Though functional impairment is mild, the cosmetic and psycho-social impairment can be considerable. The prognosis of early surgical therapy is good. The presented case also justifies surgical correction in the older child. (orig.) [German] Die Sprengel-Deformitaet ist eine angeborene Fehlbildung mit meist einseitiger Elevation und Medialrotation der Skapula. Meist ist ein Os omovertebrale vorhanden. Assoziierte skelettale Fehlbildungen sind haeufig. Obgleich funktionell wenig einschraenkend, ist die kosmetische und psycho-soziale Beeintraechtigung oft erheblich. Die Prognose der fruehen operativen Therapie ist gut. Der vorliegende Fall ermutigt zur operativen Therapie auch im hoeheren Kindesalter. (orig.)

2003-02-01

488

Internal medical therapy of gastrointestinal stroma tumors; Internistische Therapie gastrointestinaler Stromatumoren  

Energy Technology Data Exchange (ETDEWEB)

Until recently no active treatment for advanced or metastatic gastrointestinal stroma tumors (GIST) was available. The tyrosine kinase inhibitor imatinib has revolutionized the treatment of this disease and the median overall survival now reaches 5 years. The standard dose of imatinib is 400 mg per day. Locally advanced GIST should be treated with systemic therapy prior to surgical resection. Imatinib was recently licensed for adjuvant therapy following complete surgical removal of GIST in patients with a significant risk of recurrence. (orig.) [German] Bis vor einigen Jahren existierte keine wirksame systemische Therapie fuer fortgeschrittene oder metastasierte gastrointestinale Stromatumoren (GIST). Der Tyrosinkinaseinhibitor Imatinib hat die Behandlung dieser Tumoren revolutioniert, die mediane Ueberlebenszeit liegt heute bei etwa 5 Jahren. Die Standarddosierung von Imatinib betraegt initial 400 mg/Tag. Lokal ...

2009-12-15

491

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

499

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10