WorldWideScience
1

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly ...

2008-11-19

2

Syringe calibration factors and volume correction factors for the NPL secondary standard radionuclide calibrator  

CERN Document Server

The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.

2002-01-01

4

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

5

Industrial experience with an intelligent AC/DC standard  

Energy Technology Data Exchange (ETDEWEB)

AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.

1989-04-01

6

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a ...

2003-04-08

7

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically ...

2007-11-15

8

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration ...

1999-07-01

9

Incidence and management of secondary malignancies in patients with retinoblastoma and Ewing's sarcoma  

International Nuclear Information System (INIS)

Childhood cancer survivors at highest risk of developing a secondary malignancy are those with hereditary retinoblastoma. The majority of such secondary cancers will be sarcomas, most commonly of bone. One-third of these occur outside a typical radiation field, commonly in an extremity. Bone sarcoma is also the most commonly reported secondary cancer to develop among survivors of Ewing's sarcoma. In this group, radiation doses greater than 60 Gy as well as alkylating agent chemotherapy have been identified as contributors to the increased risk. The prognosis for patients with a secondary sarcoma has been poor, with few cures reported to date. However, an aggressive, combined modality approach, including radical resection, postoperative radiation, and adjuvant chemotherapy, may improve the survival rate.

10

Calibration of the Capintec CRC-712M dose calibrator for "1"8F  

International Nuclear Information System (INIS)

Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution ...

2006-04-01

11

The influence of stray radiation on image quality  

International Nuclear Information System (INIS)

The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).

12

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...

2007-07-01

13

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...

2007-05-10

14

The effects of cosmic radiation on implantable medical devices  

Energy Technology Data Exchange (ETDEWEB)

Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron ...

1996-12-31

15

Dating divergences in the Fungal Tree of Life: review and new analyses.  

Science.gov (United States)

The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...

16

Modification of NPL-CRC secondary standards radionuclide calibrator holder to suit for IPEN vials  

International Nuclear Information System (INIS)

The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)

2000-10-05

17

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual ...

2000-03-01

18

Production of secondary Deuterium in the atmosphere at various latitudes  

Energy Technology Data Exchange (ETDEWEB)

Secondary deuterium in the atmosphere are produced in interactions by primary cosmic rays. The shape of their energy spectrum depends on the primary cosmic ray spectrum incident at the top of the atmosphere. At high energies, the spectral shape depends on the primary spectrum of helium and heavy nuclei. However, at very low energies, specially below the geomagnetic cut-off, the spectral shape depends on the evaporation and recoil processes and hence almost independent of the spectral shape of the primary radiation. It is undertaken a calculation of the secondary deuterium spectrum at small atmospheric depths at various latitudes and the results will be presented.

1995-09-01

19

Spontaneous radiation emission during penetration of ions in solids  

International Nuclear Information System (INIS)

In this work, the principal continuum radiative emission processes, which occur during the penetration of ions in solids or gases, are resumed. The characteristics of the following processes are discussed: secondary electron bremsstrahlung (SEB), atomic bremsstrahlung (AB), and internuclear bremsstrahlung (INB). Recent advances of the ion channeling effects in crystal solids on the spontaneous radiative spectra are exposed. (A.C.A.S.).

1988-09-25

20

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the ...

1997-01-05

21

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the ...

1996-09-01

22

Identification of novel DNA repair proteins via primary sequence, secondary structure, and homology  

UK PubMed Central (United Kingdom)

BackgroundDNA repair is the general term for the collection of critical mechanisms which repair many forms of DNA damage such as methylation or ionizing radiation. DNA repair has...Full Text Available

23

Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code  

Energy Technology Data Exchange (ETDEWEB)

In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of ...

1998-12-01

24

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

25

ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD  

Energy Technology Data Exchange (ETDEWEB)

A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.

1983-01-01

26

Ewing's sarcoma. Radiographic pattern of healing and bony complications in patients with long-term survival  

International Nuclear Information System (INIS)

The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and ...

27

Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole  

Energy Technology Data Exchange (ETDEWEB)

Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.

1996-12-31

28

Radiation treatment of some poultry products  

International Nuclear Information System (INIS)

Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.

1988-09-26

29

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

30

Metrology measurement capabilities  

Energy Technology Data Exchange (ETDEWEB)

Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to ...

1997-06-01

31

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-15

32

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

International Nuclear Information System (INIS)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-01

33

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

34

Analysis and calibration of transient enhanced diffusion for an indium impurity in a nanoscale semiconductor device  

Energy Technology Data Exchange (ETDEWEB)

We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO{sub 2} interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-{mu}m device characteristics, such as V{sub th} and I{sub dsat}, for which the differences between simulation and experiment ...

2005-02-15

35

Analysis and calibration of transient enhanced diffusion for an indium impurity in a nanoscale semiconductor device  

International Nuclear Information System (INIS)

We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO_2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-#mu#m device characteristics, such as V_t_h and I_d_s_a_t, for which the differences between simulation and experiment less than ...

2005-02-01

36

Experimental investigation of dose calibrator response for "1"2"5I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass  

International Nuclear Information System (INIS)

The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...

2002-07-01

37

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

38

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

39

Measurement of the ratio of liquid to solid phases in a continuous ingot  

International Nuclear Information System (INIS)

A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous ...

40

Fitness of equipment used for medical exposure to ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation ...

1992-05-01

41

Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment ...

1995-05-01

42

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

43

Dead-time calibrator  

International Nuclear Information System (INIS)

... interval analyzers counting techniques discriminators electronic circuits

46

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, ...

1997-06-01

47

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm ...

1995-10-01

48

New Radiation Stable and Long-Lived Plastic Scintillators  

International Nuclear Information System (INIS)

A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic scintillators is residual ...

1993-11-15

49

Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was ...

1982-01-01

50

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

51

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

52

Secondary hazards of high power laser beam welding  

International Nuclear Information System (INIS)

Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)

1996-01-01

53

Oncogenic transformation produced by agents and modalities used in cancer therapy and its modulation  

International Nuclear Information System (INIS)

The long-term survival of certain patients after treatment with radiation or chemotherapeutic agents has allowed the realization that agents that effectively control cancer in the human subject may also possess an oncogenic potential, resulting in secondary malignancies in a significant proportion of surviving patients. A quantitative assessment of the oncogenic effects of these agents at a cellular level is important, as is information on conditions and agents that may effectively alter the development of the neoplastic state. Cell culture systems where the neoplastic transformation of cells can be scored after exposure to carcinogens offer powerful tools for evaluating the oncogenic potential of radiation and chemotherapeutic agents.

1982-01-01

54

Natural radioactivity  

International Nuclear Information System (INIS)

This chapter discusses the types of natural radioactive materials in the environment that include primordial natural radioactive materials such as K-40, U and Th, and daughters of their decay series. The discussion also includes secondary natural radioactive material generated through cosmic radiation interaction with nucleus of materials in the atmosphere. The dispersion of these radioactive materials to environment will also be part of the discussion. (Author)

55

Internal emitter limits for iodine, radium and radon daughters  

Energy Technology Data Exchange (ETDEWEB)

This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.

1984-08-15

56

A High-Frequency Secondary Event During the 2004 M6.0 Parkfield Earthquake  

Science.gov (United States)

We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection result is confirmed by ...

2007-12-01

57

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials ...

2007-08-01

58

Characterization of Radiation Instruments at the Summit of Mt. Fuji  

International Nuclear Information System (INIS)

The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was ...

2010-12-01

59

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using ...

1977-11-01

60

Surgical aspects of intestinal injury due to pelvic radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is suggested.

1985-04-01

61

Recent observations on the evolution of secondary-phase particles in zircaloy-2 under irradiation in a BWR to high burn-up  

Energy Technology Data Exchange (ETDEWEB)

The influence of radiation on the corrosion of the fuel claddings in a Light Water Reactor (LWR) has been the subject of many investigations, and different aspects of the overall phenomena have been studied by different techniques. Analysis of the evolution of Secondary-Phase Particles (SPPs) for different periods of immersion of the cladding in the reactor enables the rate of corrosion to the structure of the material to be correlated. In the case of Zircaloy-2 in a Boiling Water Reactor (BWR), SPPs are dissolved under irradiation, and their dissolution affects the rate of oxidation and other correlated phenomena. In recent studies, the Zircaloy-2 in claddings loaded in the Leibstadt BWR are analysed after one, three and five cycles. Results are presented, and give an account of the changes which occurred in the materials under irradiation. (authors)

2000-07-01

62

Uncertainty analysis of high altitude aircraft air mass zero solar cell calibration  

Energy Technology Data Exchange (ETDEWEB)

Recently the ISO standards organization has requested the PV community to establish AMO calibration methodologies for space solar cells. The PV community responded by organizing a series of workshops to review and recommend AMO calibration techniques. One of the activities of the workshop is to review the various calibration methodologies and conduct a comprehensive uncertainty analysis of each method. This paper outlines NASA`s methodology of AMO calibration using the high altitude aircraft method.

1997-12-31

63

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm using a calibrated VUV ...

1996-05-01

64

Application of low-resolution Raman spectroscopy for the analysis of oxidized olive oil  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the potential of low-resolution Raman spectroscopy for monitoring the oxidation status of olive oil. Primary and secondary oxidation parameters such as peroxide value, K"2"3"2 and K"2"7"0 were studied. Low-resolution Raman spectra ranging from 200 to 2700 cm^-^1 in a set of 126 oxidized and virgin olive oil samples were collected directly using a probe. Partial Least Squares was used to calibrate the Raman instrument for the different targeted parameters. The performance of the models was determined by using validation sets, and the best results obtained were: R^2 = 0.91, RMSEP = 2.57 for the peroxide value content; R^2 = 0.88, RMSEP = 0.37 for K"2"3"2; and R^2 = 0.90, RMSEP = 0.08 for K"2"7"0. These results demonstrated that low-resolution Raman spect...

2011-01-01

65

An off-axis Cassegrain optimal design for short focal length parabolic solar concentrators  

Energy Technology Data Exchange (ETDEWEB)

The present work addresses an off-axis Cassegrain optical concentration system. The specific primary collector analyzed, a short focal length parabolic concentrator, is at the University of Florida`s Energy Park. A secondary hyperbolic reflective element was designed to redirect the solar radiation from the primary focal plane to an off-axis target on the polar axis of the primary concentrator. This ground level target will be required for planned experimental work. The analysis was performed using a numerical ray tracing procedure that incorporates both random and systematic errors due to slope and surface irregularities. The optimization process varied secondary element size, curvature, and offset angle, and yielded information required for optimum design. As a single secondary element was found impractical, three elements were designed for use at various time of the year. The numerical analysis ...

1995-02-01

66

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

67

Calibration of the solar UV radiometers in Finland  

Energy Technology Data Exchange (ETDEWEB)

In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included

1996-12-31

68

Future needs and requirements for AMS "1"4C standards and reference materials  

International Nuclear Information System (INIS)

"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from the Third and Fourth ...

2004-08-01

69

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

70

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

71

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

72

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

73

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

74

Calorimetric sensors for energy deposition measurements  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.

1998-12-31

76

Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level  

Energy Technology Data Exchange (ETDEWEB)

The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)

2003-07-01

77

OBSERVATION OF NUCLEAR PARTICLE TRACKS IN THE ELECTRON MICROSCOPE  

Science.gov (United States)

A fine-grained photosensitive layer was prepared for electron- microscopic radioautography. The layer was obtained by evaporating Ag at low pressure and temperature on electron microscope grids and sensitizing the silvered grids with Br/sub 2/. The resulting particles had an average diameter of -- 100 A. The sensitivity of the layer to ionizing radiation was tested by sprinkling the grids with fine uranium aeetate particles and examining the processed grids in an electron microscope. Shont tracks and side spurs were observed which are probably due to alpha radiation from U/sup 235/ and secondary electrons scattered from the silver, respectively. Tests with P/sup 32/- phosphate are also described. (D.L.C.)

1962-08-01

78

Radiant{trademark} Liquid Radioisotope Intravascular Radiation Therapy System  

Energy Technology Data Exchange (ETDEWEB)

RADIANT{trademark} is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid {beta}-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid {beta}-source is Rhenium-188 in the form of sodium perrhenate (NaReO{sub 4}), Rhenium-188 is primarily a {beta}-emitter with a physical half-life of 17.0 hours. The maximum energy of the {beta}-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery ...

1998-01-16

79

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray fluorescence analysis but ...

1987-05-13

80

Estimation of half-life values of actinide radionuclides  

International Nuclear Information System (INIS)

... actinides americium 241 americium 242 americium 243 calibration standards

1986-04-15

83

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The product of this density and trapped decay ...

1994-12-31

84

Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22[sup o]C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm[sup -1] (amide I), 1200-1300 cm[sup -1] (amide III) and 550-1030 cm[sup -1] (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm[sup -1] are tyrosines and cysteines. The radiation-induced changes in the secondary ...

1993-03-01

85

Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy  

International Nuclear Information System (INIS)

The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22"oC. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm"-"1 (amide I), 1200-1300 cm"-"1 (amide III) and 550-1030 cm"-"1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm"-"1 are tyrosines and cysteines. The radiation-induced changes in the secondary structure were ...

86

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible ...

2006-11-13

87

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron ...

1997-07-01

88

Aging and compatbility of TNF-doped mylar  

Energy Technology Data Exchange (ETDEWEB)

TNF-doped Mylar is a new radiation-hard dielectric that has recently been qualified as a viable substitute for Mylar in capacitors. The advantage of TNF-doped Mylar is that it satisfies both the nuclear safety and radiation hardness requirements of weapons. Mylar is not radiation-hard. Aging and compatibility studies were carried out to insure that (1) TNF does not diffuse from the film during fabrication of the capacitor or during storage; and (2) there are no compatibility problems with aluminum foil (the conductor) or Fluorinert (the secondary dielectric). Losses of TNF were barely detectable during the vacuum bakes used in fabricating capacitors or during accelerated aging tests carried out below T{sub g} (70C) over a two year period in air. In other accelerated tests, no compatibility problems were detected with aluminum or Fluorinert. TNF-doped Mylar is now being used in the MC-4109 capacitor that ...

1990-01-01

89

Acute myelogenous leukemia following chemotherapy and radiation for rectal cancer  

Energy Technology Data Exchange (ETDEWEB)

In August 1982, a 44-year-old man was diagnosed as having rectal cancer, histologically diagnosed as well differentiated adenocarcinoma, and abdominoperineal resection and colostomy were performed. Postoperatively, he received chemotherapy with mitomycin C up to a total dose of 100 mg. In September 1986, lung metastasis occurred and he was treated with a combination chemotherapy consisting of cisplatin, pirarubicin and 5-fluorouracil. In the following year, radiation treatment (total: 6900 rad) was given for a recurrent pelvic lesion. Peripheral blood on April 30, 1988, showed anemia, thrombocytopenia and appearance of myeloblasts, and a diagnosis of acute myelogenous leukemia (FAB: M1) was made. Combination chemotherapy (including aclarubicin, vincristine, behenoyl ara-C, daunorubicin, 6-mercaptopurine, cytarabine, etoposide and prednisolone) failed to induce remission and the patient died in June 1988. This case was thought to be one of ...

1989-03-01

90

Design experience of the JRR-2 BNCT facility in JAERI  

Energy Technology Data Exchange (ETDEWEB)

The thermal neutron column of the JRR-2 reactor was remodelled in order to install a medical irradiation facility. The design experience and the cource of this remodelling are presented. At first, the thermal neutron flux was lower than expected, and the expected radiation condition was achieved by the following improvements: (1) removal of graphite from the thermal neutron column to increase the neutron flux, (2) twice increase of bismuth shielding and the shift of its position to improve the shielding effect against gamma ray, (3) application of B{sub 4}C rubber on the both surfaces of the shielding door to suppress the secondary gamma ray generation from the structural materials, (4) LiF tiles are applied on the inner face of the neutron beam exit hole to suppress the secondary gamma ray from the beam exit, and (5) installment a cone-shape polyethylene collimator to relieve the decay of thermal neutron. After the ...

1994-06-01

91

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...

2008-07-01

92

Radon emanation and soil moisture effects on airborne gamma-ray measurements  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay ...

1997-09-01

93

Radon emanation and soil moisture effects on airborne gamma-ray measurements  

International Nuclear Information System (INIS)

A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay ...

94

Fast Wire Scanner Calibration  

CERN Document Server

The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner ...

2009-01-01

95

"Advanced" data reduction for the AMBER instrument  

CERN Document Server

The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars ...

2008-01-01

96

Focused ion beam damage to MOS integrated circuits  

Energy Technology Data Exchange (ETDEWEB)

Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. Understanding the causes of this damage is important for ICS that ...

2000-05-10

97

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for ...

2005-11-23

98

Quantitative monitoring of the fluorination process by neutron counting  

Energy Technology Data Exchange (ETDEWEB)

Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated {sup 3}He-gas proportional counters. ...

1993-12-31

99

Investigation of natural radionuclides in selected NORM-samples  

International Nuclear Information System (INIS)

A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different densities, and the analysis ...

2005-09-20

100

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of dose distributions outlined in this study makes it possible to exclude the treatment related ...

2008-08-01

101

Char particle fragmentation and its effect on unburned carbon during pulverized coal combustion. Quarterly report, October 1, 1993--December 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

The information reported is for the period October I to December 31, 1993. During this quarter, activities were undertaken in Task 2. Oxygen concentrations were measured in the post-flame region of the entrained flow reactor. The sampling probe was used for the hot gas tests to sample the gas stream. Samples were injected into a gas chromatograph to determine the oxygen concentration. Results agreed with thermoequilibrium calculations that yield equilibrium compositions based on the stoichiometry of the feed gases. The axial temperature distribution along the reactor centerline was measured using a silica-coated platinum-rhodium thermocouple. Two coating techniques were tested and it was found that flame-plating silica to the thermocouple wires produced a thinner coating than a ceramic adhesive technique and therefore a smaller radiation correction. Other activities this quarter included the fabrication of a solids sampling probe support assembly and thermocouple ...

1994-02-01

102

Array coil probe: Final report  

Energy Technology Data Exchange (ETDEWEB)

Nuclear steam generator tubes have become flawed in ways that challenge conventional eddy current probes. In response to the shortcomings of conventional probes, array probes have been developed to improve measurement capabilities. However, the commercially available array probes have exhibited several weaknesses that offset the advantages and limit the applications in steam generator inspections. A primary weakness is the relatively high rate of probe failure coupled with the high unit cost for each probe. This can be costly for a utility in the time lost for probe replacement and increased radiation exposure in addition to the probe costs. Other weaknesses which make array probes undesirable for routine use are: poor mechanical and electrical characteristics; difficulty in operation and calibration; and incomplete coverage of the tube circumference. Several prototype array probes have been built to address the weaknesses of the commercially ...

1987-03-01

103

A MODEL OF THE SPECTRAL EVOLUTION OF PULSAR WIND NEBULAE  

International Nuclear Information System (INIS)

We study the spectral evolution of pulsar wind nebulae (PWNe) taking into account the energy injected when they are young. We model the evolution of the magnetic field inside a uniformly expanding PWN. Considering time-dependent injection from the pulsar and coolings by radiative and adiabatic losses, we solve the evolution of the particle distribution function. The model is calibrated by fitting the calculated spectrum to the observations of the Crab Nebula at an age of a thousand years. The spectral evolution of the Crab Nebula in our model shows that the flux ratio of TeV #gamma#-rays to X-rays increases with time, which implies that old PWNe are faint in X-rays, but not in TeV #gamma#-rays. The increase of this ratio is because the magnetic field decreases with time and is not because the X-ray emitting particles are cooled more rapidly than the TeV #gamma#-ray emitting particles. Our spectral evolution model matches the observed rate of ...

2010-06-01

104

The prooxidant-antioxidant homeostasis in Guinea pigs after exposure to fractionated low-low X-radiation and correction of its disturbances with antioxidant complex treatment  

International Nuclear Information System (INIS)

The state of prooxidant-antioxidant homeostasis in Guinea pigs exposed to whole-body fractionated X-irradiation (5 fractions of 0.2 Gy at a 24 hr interval, up to total dose of 1.0 Gy, at a dose rate of 0.425 R/min) and a possibility of its disturbance correction with the complex of vitamins C, E and P was studied. Accumulation of primary and secondary lipid peroxidation products, decrease of the ascorbic acid content, increase of the content of its oxidized forms (dehydroascorbic acid and diketogulonic acid) in radiosensitive and radioresistant organs were found. Antioxidant complex administration reduced the disturbances of prooxidant-antioxidant homeostasis, but did not provide complete normalization.

105

Considerations referring to chemical descaling of filmed carbon steels  

International Nuclear Information System (INIS)

Under operational conditions in nuclear power plants, the carbon steel components of the primary and secondary circuits react with high temperature cooling agent forming several iron oxides and oxyhydroxides. These deposits can result in tubes' constrictions, pitting and intergranular corrosion and finally to heat transfer reducing and increasing of radiation fields around the circuits, as well. The descaling process involves the chemical dissolution of the corrosion deposits by means of diluted organic acidic solutions containing usually a carboxylic acid, a reductant and one or more corrosion inhibitors. To evaluate the removing rates of these superficial films two types of methods were used, the gravimetric and potentiodynamic techniques. By correlating the experimental results, we established the chemical composition of descaling solution and two models of mechanisms applicable to our specific conditions. (authors)

2009-10-12

106

HPA - Radon Calibration Facilities  

Wastenet

... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...

107

Design Calibration and Field Use of a Stomatal Diffusion Porometer  

UK PubMed Central (United Kingdom)

Modifications of the design and calibration procedure of a diffusion porometer permit determinations of stomatal resistance which agree well with results obtained by leaf energy balance. The energy...Full Text Available

1969-06-01

108

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Function of Surface Profilometers  

Energy Technology Data Exchange (ETDEWEB)

In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.

2009-06-17

109

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the present work is the evaluation of the gamma ...

2007-11-05

110

Local thermodynamic equilibrium and related metrological issues involving collisional-radiative model in laser-induced aluminum plasmas  

Energy Technology Data Exchange (ETDEWEB)

We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al{sup 0}, Al{sup +} and Al{sup ++}). The calculations were carried for stationary plasmas, with input parameters (n{sub e} and T{sub e}) ranging respectively between 10{sup 13-18} cm{sup -3} and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to stand, the Boltzmann ...

2009-10-15

111

Local thermodynamic equilibrium and related metrological issues involving collisional-radiative model in laser-induced aluminum plasmas  

International Nuclear Information System (INIS)

We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al0, Al+ and Al++). The calculations were carried for stationary plasmas, with input parameters (ne and Te) ranging respectively between 1013-18 cm-3 and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to stand, the Boltzmann plot outputs of this code were used to ...

2009-10-01

112
113

Development and Calibration of Two and Four Wire Water ...  

Science.gov (United States)

... measurement. Power spectral density measurements are made by the dynamic signal analyzer for each channel. A cross power ...

1992-12-01

114

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

115

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, ...

2009-05-26

116

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

117

Introduction of a Secondary Blast Process into an Unlined Hot-Blast Cupola Furnace. Final Report.  

Science.gov (United States)

In a series of comprehensive tests lasting 18 months the relationship between the CO-content of the waste gas from a hot-blast cupola furnace and the amount of secondary blast was determined. The additional CO-combustion by means of the secondary blast an...

1986-01-01

118

INFLUENCE OF PERCEIVED SECONDARY STIGMA AND FAMILY ON THE RESPONSE TO HIV INFECTION AMONG INJECTION DRUG USERS IN VIETNAM  

UK PubMed Central (United Kingdom)

The full impact of secondary stigma (stigma directed at family) on an HIV-positive individual is unknown. This qualitative research explores perceptions of secondary stigma in the Vietnamese...Full Text Available

2010-12-01

119

Construction and alignment experience of Indus-1 SRS in C.A.T  

International Nuclear Information System (INIS)

A 450 MeV Synchrotron Radiation Source, Indus-1 is being constructed at Centre for Advanced Technology at Indore in central India. This paper narrates our experience in construction and alignment of synchrotron machines which was first of its kind for most of us. Careful design, planning and execution of the work yielded modest results so that alignment accuracies between 0.1 to 0.3 mm could be achieved (in booster synchrotron) and, which have proved to be adequate up till now. The building of the SRS complex was constructed such that machine rings have their foundations isolated from rest of the building. A number of 100 x 150 mm size steel plates were embedded in the concrete of floor and walls to serve as base for reference surveying marks which were established later. The pre-injector and booster ring are enclosed in a radiation shielding zone with separate ventilation system. Dipoles, quadrupoles and a few sextupoles were fiducialised ...

1996-01-01

120

STUDY OF METEOR WIND MEASUREMENT TECHNIQUES. ...  

Science.gov (United States)

... of a secondary standard (VCO) locally available. ... phase of the local secondary standards to the 10-min average of the phase of ... I3a - - \\.-e-~--. ...

1970-02-01

121

Detection of high-frequency radiation sources during the 2004 Parkfield earthquake by a matched filter analysis  

Science.gov (United States)

Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and ...

2009-12-01

122

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

123

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

124
125

Signal simulator for the calibration of eddy current probes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.

1994-01-01

126

Continuous measurement of blast-furnace coke moisture  

International Nuclear Information System (INIS)

After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).

127

Calibration system for spot welding robots in offline-teaching; Offline teaching ni okeru spot yosetsu robot yo calibration system  

Energy Technology Data Exchange (ETDEWEB)

Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)

1999-04-01

128

Key impact parameters for application of alternative source term to Kori unit 1  

International Nuclear Information System (INIS)

The object of this paper is to identify the key elements that impact a radiation dose at EAB (Exclusion Area Boundary). This study is based on the AST (Alternative Source Terms) as defined in Regulatory Guide 1.183. The LOCA (Loss of Coolant Accident) and the LRA (Locked Rotor Accident) are selected as limiting cases. A sensitivity analysis of accidental behavior with respect to various parameters during LOCA and LRA at Kori Unit 1 is also undertaken for the following objectives: to determine the limiting parameters, to find the impact trend of the radiation dose, and to find the safety margin between AST and TID (Technical Information Document) methodologies. This work confirms that key parameters are particulate removal rate, decontamination factor, iodine chemical form, gap fraction, partitioning factor, and the impact of isotopes group. Comparing TID with AST, the radiation dose of TID is about 80% greater than that of ...

2010-08-01

129

Central engine of quasars and AGNs: a relativistic proton radiative shock  

International Nuclear Information System (INIS)

Active galactic nuclei (AGNs) and quasars (QSOs) appear to emit roughly equal energy per decade from radio to gamma-ray energies (e.g. Ramaty and Ligenfelter 1982). This argues strongly for a nonthermal radiation mechanism (see Rees 1984). In addition, statistical studies have indicated that the spectra of these objects in the IR-UV and 2 to 50 keV x-ray band, can be fitted very well with power laws of specific indices. These spectral indices do not seem to depend on the luminosity or morphology of the objects (Rothschild et al. 1983; Malkan 1984), and any theory should account for them in a basic and model independent way. If shocks accelerate relativistic protons via the first-order Fermi mechanism (e.g. Axfor 1981), the radiating electrons can be produced as secondaries throughout the source by proton-proton (p-p) collisions and pion decay, thus eliminating Compton losses (Protheroe and Kazanas 1983). As shown by Kazanas ...

1985-08-01

130

Studies of aerosol formation in power plant plumes - II. Secondary aerosol formation in the Navajo generating station plume  

Energy Technology Data Exchange (ETDEWEB)

Aerosol and gas measurements were made with the University of Minnesota Mobile Laboratory (UMML) during the VISTTA programme near Page, Arizona. The UMML was stationed on Zilnez Mesa approx. 65 km east of the Navajo coal-fired power plant. Measurements were made both in and out of the power plant plume and were made during the day and night. Measured parameters included aerosol size distributions, Aitken nuclei count, ozone and sulphur dioxide concentrations, the aerosol light scattering coefficient, and meteorological parameters including ultraviolet radiation intensity. Concentrations of NO and NO/SUB/x were occasionally measured. Data show clear evidence of gas-to-particle conversion in the plume with aerosol volume being added in the 0.01 MUm - 0.32 MUm dia. range and new particles being formed. The observed excess aerosol volume depends strongly upon the SO/SUB/2 concentrations and the time of day with none observed in plume parcels which were not exposed to ...

1981-01-01

131

phenAtmoPrecipitation.owl  

Science.gov (United States)

The bands may be classified as primary if they merge into the eyewall encircling the eye of the storm, or secondary if they are disconnected from the ...

133

Secondary Titanium Processes  

International Science & Technology Center (ISTC)

Research and Development of Resource-Saving Technology for Manufacturing of Titanium Semifinished Items from Chips

137

Tests of the ONERA Calibration Models in Three Transonic ...  

Science.gov (United States)

... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...

1976-11-01

138

Stability of modulation transfer function calibration of surface profilometers using binary pseudo-random gratings and arrays with nonideal groove shapes  

Energy Technology Data Exchange (ETDEWEB)

The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.

2010-03-31

139

Satellite Calibration Data. Annual Data Report - 1977  

Science.gov (United States)

... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...

1979-08-01

140

Salt Lake City shows hot and cold spots - NASA ... - Science@NASA  

Science.gov (United States)

Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...

141

LBA Calibrator Survey - NASA  

Science.gov (United States)

Group deal delay solution has fit 42 psec with 2.4% outliers. Group delay ambiguities with spacing 3.9 ns (another world record!) were successfully resolved. ...

142

Ionization-chamber-dependent factors for calibration of megavoltage X-ray and electron beam therapy machines  

International Nuclear Information System (INIS)

When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that ...

143

DMSP Special Sensor Microwave/Imager Calibration ...  

Science.gov (United States)

... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...

2011-05-14

144

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

145

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

146

Calibrating Cosmological Chronometers: White Dwarf Masses ...  

Science.gov (United States)

... The second scenario is limited by the age of our Galaxy such that the lowest-mass WD that could be formed via single star evolution is ~0.47 M ...

2011-05-14

147

BIG BEAR SOLAR OBSERVATORY - NASA Technical Report Server (NTRS)  

Science.gov (United States)

replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...

148

AGARD Flight Test Techniques Series. Volume 1. Calibration ...  

Science.gov (United States)

... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...

1983-09-01

149

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

British Library Electronic Table of Contents (United Kingdom)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...

2007-01-01

150

Effects of ionizing radiation on properties of monolayer and multilayer flexible food packaging materials  

International Nuclear Information System (INIS)

Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are produced upon irradiation. These products may affect organoleptic properties and thus shelf-life of prepackaged irradiated foods. ...

1999-05-01

151

A new measurement of the antiproton-to-proton flux ratio up to 100 GeV in the cosmic radiation  

CERN Document Server

A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imaging calorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter particle annihilations.

2008-01-01

152

Second malignancies after treatment for Ewing's sarcoma  

International Nuclear Information System (INIS)

Background: Some former retrospective studies have suggested that patients with Ewing's sarcoma might have a very high risk for developing secondary sarcomas if treated with radiotherapy. We have evaluated the risk of second malignancies (SM) in patients treated in the German Cooperative Ewing's Sarcoma Studies CESS 81 and CESS 86. Materials and methods: From January 1981 through June 1991, a total number of 674 patients was registered in the two multicentric Ewing's sarcoma trials CESS 81 (1981 through 1985) and CESS 86 (1986 through June 1991). The systemic treatment consisted in both studies of a four-drug-chemotherapy (VACA= vincristine, actinomycin D, cyclophosphamide and adriamycin; or VAIA= vincristine, actinomycin D, ifosfamide and adriamycin) and a total number of four courses, each lasting nine weeks, was recommended by the protocol. Local therapy was either complete surgery or surgery plus postoperative radiotherapy with 36-46Gy or definitive ...

153

Study of the Effects of Ambient Conditions Upon the Performance of Fan Powered, Infrared, Natural Gas Burners  

Energy Technology Data Exchange (ETDEWEB)

Fourier transform infrared spectroscopy is a simple, fast, reliable and nondestructive analytical method. By using the method developed in Clark Atlanta University, consistent and reliable infrared spectral results can be obtained. An accurate radiant energy can be calculated from these infrared spectra by using a blackbody as the calibration standards. By means of the specially-designed-and-lab-made sampling inlet and the Horiba gas analyzers, the compositions of CO{sub 2}, CO, UCH, NOx and O{sub 2} etc. from the combustion exhaust gases have been on-line accurately analyzed. The commercial natural gas IR burner performed differently in the different conditions. For the methane-air combustion, at the equivalence ratio {Phi} = 1, the IR burner produced its maximum radiation efficiency, {approximately}31.4%, and the concentration of CO{sub 2} reached its maximum value, {approximately}10.7%. In the fuel-lean region, the O{sub 2} concentration in ...

1997-03-31

154

Gamma spectrometry calibrations with natural radioactive materials  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).

1996-02-01

155

Gamma spectrometry calibrations with natural radioactive materials  

International Nuclear Information System (INIS)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).

156

Determination of efficiency curves of germanium detectors using natural radioactive materials  

International Nuclear Information System (INIS)

Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).

157

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable ...

2011-03-14

158

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test ...

2010-07-26

159

Opportunistic Cooperation in Cognitive Femtocell Networks  

CERN Document Server

We investigate opportunistic cooperation between unlicensed secondary users and legacy primary users in a cognitive radio network. Specifically, we consider a model of a cognitive network where a secondary user can cooperatively transmit with the primary user in order to improve the latter's effective transmission rate. In return, the secondary user gets more opportunities for transmitting its own data when the primary user is idle. This kind of interaction between the primary and secondary users is different from the traditional dynamic spectrum access model in which the secondary users try to avoid interfering with the primary users while seeking transmission opportunities on vacant primary channels. In our model, the secondary users need to balance the desire to cooperate more (to create more transmission opportunities) with the need for maintaining ...

2011-01-01

160

Radial dose distribution of 6.0 MeV/n #alpha#-particle in water  

International Nuclear Information System (INIS)

For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using accelerator beam, the dose ...

2003-08-17

161

Micro area analysis and measurement of electronic device material (challenge to utmost limits). Characterization of interface elect`ron structure by photon-and electron-spectroscopies; Denshi debaisu yo zairyo no bisho ryoiki bunseki-keisoku (kyokugen eno chosen). Koshi-denshi bunkoho ni yoru kaimen denshi jotai hyoka  

Energy Technology Data Exchange (ETDEWEB)

A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be investigated by ...

1995-07-20

162

Impact of more intensive written information in patients having radical radiation therapy: Results of a prospective randomized phase III trial  

International Nuclear Information System (INIS)

Background and purpose: A diagnosis of malignancy and its treatment is a very stressful time for patients and their families. This study was conducted to determine the impact of more intensive written information on patients' anxiety levels. The secondary aim was to determine the impact of this information on patients' satisfaction levels. Materials and methods: This prospective randomized trial consisted of patients with a pathological diagnosis of cancer having radical radiotherapy (RT). Patients were randomized to receive the more intensive information (including written information and a telephone call from the research nurse) or not to receive the more intensive information at the time of their initial consultation with the radiation oncologist. Study questionnaires measuring anxiety (STAI form) were completed prior to their first consultation (baseline) at the time of simulation (pre-RT) and at the completion of radiotherapy. A second ...

2010-08-01

163

Formation of the natural sulfate aerosol  

Energy Technology Data Exchange (ETDEWEB)

Anthropogenic sulfate aerosol, together with particles from biomass burning, may significantly reduce the climatic warming due to man-made greenhouse gases. The radiative forcing of aerosol particles is based on their ability to scatter and absorb solar radiation (direct effect), and on their influences on cloud albedos and lifetimes (indirect effect). The direct aerosol effect depends strongly on the size, number and chemical composition of particles, being greatest for particles of 0.1-1 {mu}m in diameter. The indirect aerosol effect is dictated by the number of particles being able to act as cloud condensation nuclei (CCN). For sulfate particles, the minimum CCN size in tropospheric clouds is of the order of 0.05-0.2 {mu}m. To improve aerosol parameterizations in future climate models, it is required that (1) both primary and secondary sources of various particle types will be characterized at a greater accuracy, and (2) ...

1996-12-31

164

T Plant secondary containment and leak detection upgrades  

Energy Technology Data Exchange (ETDEWEB)

The W-259 project will provide upgrades to the 2706-T/TA Facility to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. The project provides decontamination activities supporting the environmental restoration mission and waste management operations on the Hanford Site.

1995-10-19

165

Selecting Folded Proteins from a Library of Secondary Structural Elements  

UK PubMed Central (United Kingdom)

A protein evolution strategy is described by which double-stranded DNA fragments encoding defined E. coli protein secondary structural elements (α-helices, β-strands...Full Text Available

2008-01-09

166

Secondary motor disturbances in 101 patients with musician's dystonia  

UK PubMed Central (United Kingdom)

ObjectiveMusician's focal dystonia is usually considered to be task specific but secondary motor disturbances have been reported also. We carried out a detailed evaluation of the...Full Text Available

2007-09-01

167

Safety limits for utilization of secondary mining operations at deposits  

Energy Technology Data Exchange (ETDEWEB)

A procedure was developed to monitor boundaries within which secondary mining operations can be applied. Principal techniques include instrument and operative-remote observations of earth shifts and aerial photography of displacements on the surface of the trough.

1982-01-01

168

Relationship between mRNA secondary structure and sequence variability in Chloroplast genes: possible life history implications  

UK PubMed Central (United Kingdom)

BackgroundSynonymous sites are freer to vary because of redundancy in genetic code. Messenger RNA secondary structure restricts this freedom, as revealed by previous findings in...Full Text Available

169

One-year analysis of the iStent trabecular microbypass in secondary glaucoma  

UK PubMed Central (United Kingdom)

Purpose:To evaluate the midterm efficacy and safety of the iStent® glaucoma device in patients with secondary open-angle glaucoma.Patients...Full Text Available

2011-01-01

170

Mesenchymal cell re-modeling during mouse secondary palate re-orientation  

UK PubMed Central (United Kingdom)

The formation of mammalian secondary palate requires a series of developmental events such as growth, elevation and fusion. Despite recent advances in the field of palate development, the process...Full Text Available

2010-07-01

171

Massive Concha Bullosa with Secondary Maxillary Sinusitis  

UK PubMed Central (United Kingdom)

Concha bullosa is a common anatomic variation of the middle turbinate; however, sinusitis secondary to the concha bullosa is rare. A 52-yr-old woman presented with nasal obstruction and posterior nasal...Full Text Available

2008-12-01

172

Evaluation of field application of boric acid  

International Nuclear Information System (INIS)

Results of field applications of boric acid in the secondary coolant circuits of seven PWR units for the purpose of reducing the rate of corrosion denting are reported. Based on available data at the power plants considered in this study, it was not possible to support or refute the benefit of using boric acid secondary water treatment.

1985-03-01

173

Computing the Partition Function for Kinetically Trapped RNA Secondary Structures  

UK PubMed Central (United Kingdom)

An RNA secondary structure is locally optimal if there is no lower energy structure that can be obtained by the addition or removal of a single base pair, where energy is defined according...Full Text Available

174

Anthracenedione Derivatives as Anticancer Agents Isolated from Secondary Metabolites of the Mangrove Endophytic Fungi  

UK PubMed Central (United Kingdom)

In this article, we report anticancer activity of 14 anthracenedione derivatives separated from the secondary metabolites of the mangrove endophytic fungi Halorosellinia sp. (No. 1403)...Full Text Available

175

Analysis of the VVER-440 reactor steam generator secondary side with the RELAP5/MOD3 code  

Energy Technology Data Exchange (ETDEWEB)

Nuclear Engineering Laboratory of the Technical Research Centre of Finland has widely used RELAP5/MOD2 and -MOD3 codes to simulate horizontal steam generators. Several models have been developed and successfully used in the VVER-safety analysis. Nevertheless, the models developed have included only rather few nodes in the steam generator secondary side. The secondary side has normally been divided into about 10 to 15 nodes. Since the secondary side at the steam generators of VVER-440 type reactors consists of a rather large water pool, these models were only roughly capable to predict secondary side flows. The paper describes an attempt to use RELAP5/MOD3 code to predict secondary side flows in a steam generator of a VVER-440 reactor. A 2D/3D model has been developed using RELAP5/MOD3 codes cross-flow junctions. The model includes 90 volumes on the steam generator ...

1993-12-31

176

Analysis of the VVER-440 reactor steam generator secondary side with the RELAP5/MOD3 code  

International Nuclear Information System (INIS)

Nuclear Engineering Laboratory of the Technical Research Centre of Finland has widely used RELAP5/MOD2 and -MOD3 codes to simulate horizontal steam generators. Several models have been developed and successfully used in the VVER-safety analysis. Nevertheless, the models developed have included only rather few nodes in the steam generator secondary side. The secondary side has normally been divided into about 10 to 15 nodes. Since the secondary side at the steam generators of VVER-440 type reactors consists of a rather large water pool, these models were only roughly capable to predict secondary side flows. The paper describes an attempt to use RELAP5/MOD3 code to predict secondary side flows in a steam generator of a VVER-440 reactor. A 2D/3D model has been developed using RELAP5/MOD3 codes cross-flow junctions. The model includes 90 volumes on the steam generator ...

1992-09-29

177

Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue  

International Nuclear Information System (INIS)

Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, dose-volume histograms (DVHs), the mean lung ...

2003-10-01

178

Comparison and Physical Interpretation of MCNP and TART Neutron and Gamma Monte Carlo Shielding Calculations for a Heavy-Ion ICF System  

Energy Technology Data Exchange (ETDEWEB)

For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam lines, each focused by six magnets. A 3-D ...

2002-07-01

179

Calibration free laser-induced breakdown spectroscopy of oxide materials  

Energy Technology Data Exchange (ETDEWEB)

The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse ...

2010-08-15

180

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...

1989-08-15

181

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

183
184

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

186

Secondary stresses on transmission tower structures  

Energy Technology Data Exchange (ETDEWEB)

The power industry is moving toward the use of high-voltage transmission lines on tall, flexible towers. These towers are designed for heavier loadings than were previous towers, but the secondary effects of tower displacement tend to be ignored in the present day tower analysis. This paper examines the secondary effects from the large displacement of flexible towers, reviews the secondary stresses arising from joint rigidity and member continuity, and examines the reliability of tower strength predicted by the ASCE design guidelines. More realistic tower test acceptance criteria and a more reliable tower design methodology are suggested.

1984-06-01

188

Corrosion properties of carbon steels under PWR secondary water environment  

International Nuclear Information System (INIS)

... Japan) Kobayashi, Minoru AITEL Corp., Yokohama, Kanagawa (Japan)

2009-05-01

189

Particle Flow at CMS and the ILC  

CERN Document Server

This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy ...

2010-01-01

190

Low-range flowmeters for use with vacuum and leak standards  

Energy Technology Data Exchange (ETDEWEB)

Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.

1987-05-01

191

Experimental compliance calibration for the mixed-mode bending (MMB) specimen  

Energy Technology Data Exchange (ETDEWEB)

A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.

1997-12-31

192

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...

2010-10-15

193

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...

2010-10-01

194

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

195

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

196

Analysis of installation damage tests for LRFD calibration of reinforced soil structures  

British Library Electronic Table of Contents (United Kingdom)

North American design codes are now committed to the development of load and resistance factor design (LRFD) for reinforced soil structures including internal stability limit states. Reliability-based analysis is required to carry out these calibrations. A framework for LRFD calibration has been proposed by the writers that requires bias statistics for load and resistance terms for each limit state function. In this paper the formulation of the limit state for reinforcement tensile rupture is developed and the component strength-reduction bias statistics identified. The paper describes how to compute bias statistics from project-specific installation damage trials for use in reliability-based design for the reinforcement rupture limit state or using data from multiple sources for LRFD cali...

2011-01-01

197

A refined lack-of-fit statistic to calibrate pesticide fate models for responsive systems  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: Calibration by inverse modelling was performed with the MACRO transport and fate model using long-term (>10 years) drainflow and isoproturon (IPU) data from western France. Two lack-of-fit (LOF) indices were used to control the inverse modelling: sum of squares (SS) and an alternative statistic called the vertical-horizontal distance integrator (VHDI), which is designed to account for offsets in observed and predicted arrival times of peak IPU concentration. With these data, SS was artificially inflated because it is limited to comparison of predicted and observed IPU concentrations that are concurrent in time. The LOFs were used along with the index of agreement (d) and the correlation coefficient (r) to ascertain the fit of the calibrated models. RESULTS: Predicted arrival ti...

2009-01-01

198

Calibration and analysis of soil carbon efflux estimates with closed chambers at Forsmark and Laxemar  

International Nuclear Information System (INIS)

The Forsmark and the Laxemar investigation areas are examined by the Swedish Nuclear Fuel and Waste Management Co. for a possible construction of a deep repository for nuclear waste. In the case of a future leakage of waste, the radioactive isotopes could end up in the ecosystems above the repository. The fate of the radionuclides and their possible radiological impacts are then highly determined by ecosystem carbon cycling. An important part of the carbon cycling is the soil carbon effluxes, and in the investigation areas soil carbon effluxes have been examined with the closed chamber technique. This paper is divided into two parts. Firstly, there were problems with the equipment measuring the soil carbon dioxide efflux, and the first part is a description of the problem, how it was corrected and its possible causes. The second part is a manual in how to analyse data and calculate annual estimates of soil carbon efflux. The field measurement by the EGM-4 is just an occasional estimate ...

2007-01-01

199

UNS YMSCP QA support task: Quarterly technical progress report, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)

1991-07-30

200

THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA  

Science.gov (United States)

tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...

201

Spectral Cross-calibration of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT Data using Gamma-Ray Bursts  

CERN Document Server

We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...

2010-01-01

202

Measurements of Spectral Characteristics of Swimmer Targets ...  

Science.gov (United States)

... 3.0 Radar Measurements 3-1 3. 1 Spectral Density Measurements 3-2 3. 1. 1 System Calibration 3-3 ... 3. 1 SPECTRAL DENSITY MEASUREMENTS ...

1974-05-01

203

Los Alamos second-generation system for passive and active neutron assays of drum-size containers  

International Nuclear Information System (INIS)

We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...

1972-09-17

204

Exploding Bridgewire Electrical System Test Unit.  

Science.gov (United States)

The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...

1964-01-01

205

Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.  

Science.gov (United States)

This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...

1979-01-01

206

COSPIN-ANISOTROPY TELESCOPE for ULY - PDS - NASA  

Science.gov (United States)

To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...

207

Binary pseudo-random gratings and arrays for calibration of the modulation transfer function of surface profilometers: recent developments  

Energy Technology Data Exchange (ETDEWEB)

The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. ...

2009-07-07

208

Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

209

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

210

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

212

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

214

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

215

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

216

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

217

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

218

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

219

Residential vertical geothermal heat pump system models: Calibration to data  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

1997-12-31

220

Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.

1997-06-01

221

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

222

Capability of the PAMELA Time-Of-Flight to identify light nuclei: results from a beam test calibration  

CERN Document Server

PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.

2008-01-01

223

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

224

Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G  

Energy Technology Data Exchange (ETDEWEB)

Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...

1997-12-31

225

Software framework and jet energy scale calibration in the ATLAS experiment; Environnement logiciel et etalonnage de l'echelle en energie des jets dans l'experience ATLAS  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This calibration ...

2006-07-01

226

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET{sub {infinity}}H{sub ...

2006-07-01

227

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace ...

2005-09-07

228

The interaction of alcohol radicals with human hemoglobin. Pt. 1. Spectral properties of hemoglobin in the visible range  

International Nuclear Information System (INIS)

Aqueous deoxyhemoglobin solutions (2 mg/ml) were gamma-irradiated by a "6"0Co source in the presence of methanol, ethanol, 1-butanol and t-butanol under N_2O or argon. The effects of the interaction of the particular alcohol radical species with hemoglobin were determined according to the detected spectral alterations in the visible range. The amounts of stable final products in the form of methemoglobin (MetHb) and the sum of hemichromes and cholehemichromes (Hemichr) were estimated in irradiated preparations. For preparations irradiated under N_2O, the radiation yield for MetHb formation was three-fold lower in the presence of ethanol and 1-butanol [G(MetHb) = 0.33[ compared with preparations irradiated in the presence of t-butanol or without alcohol [G(MetHb) = 1.00[. The yield of hemichromes and cholehemichromes in preparations irradiated under N_2O increased in the order: ethanol (G = 0.38), 1-butanol (B = 0.52), t-butanol (G = 0.59), and in the absence of ...

229

Measurement of the cosmic-ray antiproton flux and a search for an antihelium  

Energy Technology Data Exchange (ETDEWEB)

A balloon-borne instrument has measured the cosmic-ray antiproton flux between 130 and 320 MeV and searched for antihelium between 130 and 370 MeV per nuclear. These particles were selected from the background of normal-matter cosmic rays by combining a selective trigger with a detailed spark chamber visualization of each recorded event. Antiprotons are identified by their characteristic annihilatin radiation. Residue from background processes meeting the selection criteria is small. The observed 14 antiprotons yield a measured differential flux of 1.7 +- 0.5 x 10/sup -4/ antiprotons m/sup -2/ sr/sup -1/ s/sup -1/ MeV/sup -1/ at the top of the atmosphere. The corresponding antiproton/proton ratio is 2.2 +- 0.6 x 10/sup -4/,, only slightly smaller than the ratio observed by other experiments at higher energies. Thus the antiprotons have a spectral shape similar to the protons, at least down to about 100 MeV. The expected flux of these particles can be calculated ...

1981-09-15

230

Floating zone crystal growth of selected R2PdSi3 ternary silicides  

Energy Technology Data Exchange (ETDEWEB)

Substitution of various rare earths R within the class of R2PdSi3 single crystals with hexagonal AlB2-type crystallographic structure reveals the systematic dependence of anisotropic magnetic properties governed by the interplay of crystal-electric field effects and magnetic two-ion interactions. Here we compare the floating zone (FZ) crystal growth with radiation heating of compounds with R = Tb, Tm, Pr, and Gd. The congruent melting behavior enabled moderate growth velocities of 3 to 5 mmh-1. The preferred growth directions are close to the basal plane of the hexagonal unit cell. The composition of the crystals, except of Tb2PdSi3, is slightly Pd-depleted with respect to the nominal composition 16.7 at.% Pd. Thin precipitates of RSi secondary phases were detected in the crystal matrix. Their phase fraction can be diminished by growth from Pd-rich melt compositions and annealing treatments. The compounds exhibit antiferromagnetic order below ...

2011-06-01

231

Comparative studies on titanium and tantalum oxides thin film structures for laser mirrors, deposited by ion assisted gun  

International Nuclear Information System (INIS)

For obtaining radiation less damagable laser mirrors, a preliminary optimization of film fabrication suitable for the analysis of laser damage mechanism has been done as the first step. Here, the optimization requires not only the stable fabrication process but also the ideal film structure i.e., the amorphous and smooth film structure simultaneously, eliminating latently unwanted secondary effects such as light scattering during laser damage test. For this purpose, we adopted the ion assisted deposition (IAD) method and modified the deposition conditions for titanium and tantalum oxide films, both of which compose typical high index layers, and where SiO_2 layers are also chosen as low index layers because of their amorphous and smooth nature, in alternative multilayer laser mirrors. Surface and cross sectional film structures and film crystallinity are compared and characterized, using a high resolution SEM and a x-ray diffractometer, ...

1996-10-07

232

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and elemental distribution ...

2005-06-11

233

A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP  

International Nuclear Information System (INIS)

Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. Confusions for the inspected tubes may occur from deflection of the manipulators. To reduce the deflections ...

2010-10-01

234

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

235

Pulsatile viscous flow in a curved pipe: Effects of pulsation on the development of secondary flow  

International Nuclear Information System (INIS)

This work presents an experimental and numerical study of pulsated Dean flow, three-dimensional pulsatile flow in a curved pipe. The numerical study is performed by CFD code (Fluent 6) in which a pulsated velocity field is imposed as an inlet condition. The experimental setup involves principally a 'Scotch-yoke' pulsatile generator and a 90o bend. Laser Doppler Velocimetry (LDV) measurements have shown that the Scotch-yoke generator produces pure sinusoidal instantaneous mean velocities with a mean deviation of 3%. Visualizations by laser-induced fluorescence (LIF) and velocity measurements, coupled with the numerical results, have permitted analysis of the evolution of the swirling secondary flow structures that develop along the bend during the pulsation phase. These measurements were made for a range of stationary Reynolds number (300?Rest?1200), frequency parameter (1??=r0(?/?)1/2max,osc/Ust). We observe satisfactory agreement between the numerical and ...

2010-10-01

236

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

238

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

239

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

240

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

241

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

242

Secondary side concept to prevent steam generator tube corrosion  

International Nuclear Information System (INIS)

Some examples are given of design adaptations, e.g. U-bend support, tube spacer grid, flow distribution baffle, triangular tube pitch, tube-tubeplate sheet connection, which reduce the tendency to various types of corrosion (stress corrosion cracking, tube denting, tube wastage, intergranular cracking). A basic diagram of the secondary circuit is shown. Oxygen, corrosion product and impurity control in the secondary circuit is described. (E.J.). 19 figs., 6 refs.

1989-05-01

243

Formation and decay of secondary actinides in water reactor and fast neutron reactors  

International Nuclear Information System (INIS)

Actinides other than the main uranium or plutonium isotopes take a growing part in the different stages of the nuclear cycle. For the French nuclear power program based on the development of light water reactors and fast breeders, many evaluations of the secondary actinides build up are made for the both reactor types using mainly the existing reactor codes. The comparison of these foreseen compositions with experimental results allows to perform some adjustments of the neutronic data. The secondary actinide compositions are given for some typical fuels and their consequences on the nuclear cycle are discussed. An hypothetical burning of these wastes in fast reactors has been studied and the main conclusions are reported.

244

Advanced technologies on steam generators. Study on thermal-hydraulic behavior of horizontal steam generator  

Energy Technology Data Exchange (ETDEWEB)

The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author)

1996-12-31

245

Advanced technologies on steam generators. Study on thermal-hydraulic behavior of horizontal steam generator  

International Nuclear Information System (INIS)

The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermal-hydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (author).

1996-10-15

246

SECOND QUARTERLY REPORT DEVELOPMENT OF SECONDARY - NASA Technical ...  

Science.gov (United States)

cellulose casing material made by Food Products Division,. Union Carbide Corporation. tion of the anode from oxygen generated at the charging electrode. ...

247

Phylogenetic Relationships in Pterodroma Petrels Are Obscured by Recent Secondary Contact and Hybridization  

UK PubMed Central (United Kingdom)

The classification of petrels (Pterodroma spp.) from Round Island, near Mauritius in the Indian Ocean, has confounded researchers since their...Full Text Available

248

Phenolic compounds in ectomycorrhizal interaction of lignin modified silver birch  

UK PubMed Central (United Kingdom)

BackgroundThe monolignol biosynthetic pathway interconnects with the biosynthesis of other secondary phenolic metabolites, such as cinnamic acid derivatives, flavonoids and condensed...Full Text Available

249

Pachydermoperiostosis: scintigraphic, thermographic, plethysmographic, and capillaroscopic observations.  

UK PubMed Central (United Kingdom)

A unique case of pachydermoperiostosis, multiple epiphyseal dysplasia, and secondary osteoarthritis is described. An additional interesting feature was the presence of acroosteolysis of the distal phalanges...Full Text Available

1983-02-01

250

PWR horizontal steam generator in USSR  

International Nuclear Information System (INIS)

This paper describes the construction of PWR horizontal steam generator in Soviet Union, the water chemistry treatment for secondary side, the design of steam separator, the test of heat transfer characteristics and operation. (author).

1985-01-01

251

Magnetic resonance imaging in human lymphodemas  

International Nuclear Information System (INIS)

The MRI's of 16 patients with either primary or secondary lymphatic disorders are evluated and the findings are compared to those from lymphangioscintigraphy or surgery. (author).

1989-09-02

252

Genetic Variation of Lodgepole Pine, Pinus contorta var. latifolia, Chemical and Physical Defenses that Affect Mountain Pine Beetle, Dendroctonus ponderosae, Attack and Tree Mortality  

British Library Electronic Table of Contents (United Kingdom)

Plant secondary chemistry is determined by both genetic and environmental factors, and while large intraspecific variation in secondary chemistry has been reported frequently, the levels of genetic variation of many secondary metabolites in forest trees in the context of potential resistance against pests have been rarely investigated. We examined the effect of tree genotype and environment/site on the variation in defensive secondary chemistry of lodgepole pine, Pinus contorta var. latifolia, against the fungus, Grosmannia clavigera (formerly known as Ophiostoma clavigerum), associated with the mountain pine beetle, Dendroctonus ponderosae. Terpenoids were analyzed in phloem samples from 887, 20-yr-old trees originating from 45 half-sibling families planted at two sites. Samples were coll...

2011-01-01

254

Cisco Presentation Guide - NASA  

Science.gov (United States)

MilStar,. Globalstar,. Others. DVB. Satellite. Internet. Home Agent. Foreign Agent. Foreign Agent . Reparenting the HA. Primary. Home Agent. Secondary ...

255

Bone geometry, biomechanics, and mineral content of the distal radius in uremic patients with severe hyperparathyroidism  

International Nuclear Information System (INIS)

Bone integrity and mineral status were studied with a noninvasive method in uremic patients with severe secondary hyperparathyroidism undergoing maintenance hemodialysis.

1999-04-01

256

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...

2010-10-01

257

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

Energy Technology Data Exchange (ETDEWEB)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...

2007-12-15

258

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

International Nuclear Information System (INIS)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...

2007-12-01

261

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

269

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

273

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...

274

Radiation Therapy in Treating Patients With Prostate Cancer  

Science.gov (United States)

Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility

2011-09-13

276

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

278

[Comparison of wound morphology following gunshots by machine guns and sub-machine guns].  

Science.gov (United States)

Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...

279

The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs  

CERN Document Server

We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) ...

2009-01-01

280

Online processing in the ALICE DAQ The detector algorithms  

CERN Document Server

ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...

2010-01-01

281

Heat pump modeling in TRNSYS  

Energy Technology Data Exchange (ETDEWEB)

Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within one per cent of the ...

1997-11-01

282

Development of highly reliable screening by using x-ray fluorescence spectrometry. Applications to determine lead in tin plated and tin-bismuth plated samples  

International Nuclear Information System (INIS)

A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)

2009-03-01

283

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

284

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

285

{sup 3}He spectrum at small atmospheric depths for different geomagnetic cutoff values  

Energy Technology Data Exchange (ETDEWEB)

It is carried out a calculation to determine the energy spectra of secondary {sup 3}He at small atmospheric depths. It is produced in the spallation reaction of primary helium and heavier nuclei in the overlying atmosphere. It is examined the effect of the geomagnetic cut-off on the spectral shape of the secondary {sup 3}He nuclei. The calculations are being carried out for both solar minimum and maximum periods. Results from these calculations will be presented at the Conference.

1995-09-01

286

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

1981-05-01

287

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

International Nuclear Information System (INIS)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

288

National Dioxin Study Tier 4 - Combustion Sources: Final Test Report - Site 10, Secondary Copper Recovery Cupola Furnace MET-A,  

Science.gov (United States)

The report summarizes the results of a dioxin/furan emissions test of a secondary copper recovery cupola furnace equipped with an afterburner for hydrocarbon emissions control and two baghouses for particulate emissions control. The cupola furnace is used...

1987-01-01

289

Management considerations of the large primary-to-secondary leakage accidents  

Energy Technology Data Exchange (ETDEWEB)

The management procedure of a large PRISE (Primary-to-Secondary) leakage accident at Loviisa nuclear power plant taking into account the plant modifications which are expected to be realized during 1995-96 is described. The management procedure has been validated by performing thermal hydraulic analyses with the computer code RELAP5/MOD3 and the results from these analyses are also shortly discussed. (4 refs., 6 figs., 1 tab.).

1993-12-31

290

Interaction between primary and secondary sporocysts of Schistosoma mansoni and the internal defence system of Biomphalaria resistant and susceptible to the parasite  

Scientific Electronic Library Online (English)

Abstract in english The outcome of the interaction between Biomphalaria and Schistosoma mansoni depends on the response of the host internal defence system (IDS) and the escape mechanisms of the parasite. The aim of this study was to evaluate the responsiveness of the IDS (haemocytes and soluble haemolymph factors) of resistant and susceptible Biomphalaria tenagophila lineages and Biomphalaria glabrata lineages in the presence of in vitro-transformed primary sporocysts and secondary sporocys (more) ts obtained from infected B. glabrata. To do this, we assayed the cellular adhesion index (CAI), analysed viability/mortality, used fluorescent markers to evaluate the tegumental damage and transplanted secondary sporocysts. B. tenagophila Taim was more effective against primary and secondary sporocystes than the susceptible lineage and B. glabrata. Compared with secondary sporocysts exposed to B. ...

2011-06-01

291

Direct measurements of secondary water inventory of steam generator PGV-213 in operation  

Energy Technology Data Exchange (ETDEWEB)

Results of weight measurement of PGV-213 steam generator during filling in, heating-up and power increase are described. Special measurement system based on stress gauges has been developed. Method of derivation of secondary water inventory is described. Comparison of the data for two steam generators prove accuracy of the measurements. (orig.). 1 refs.

1997-12-31

292

Cosmic ray antimatter: is it primary or secondary  

Energy Technology Data Exchange (ETDEWEB)

The relative merits and difficulties of the primary and secondary origin hypotheses for the observed cosmic ray antiprotons, including the low energy measurement of Buffington, were examined. It is concluded that the cosmic ray antiproton data may be strong evidence for antimatter galaxies and baryon symmetric cosmology. The present antiproton data are consistent with a primary extragalactic component having antiproton/proton approximately equal to .0032 + or - 0.7.

1981-04-01

293

Calculation of conditions with drop of the level over PGV-1000 secondary side using dinamika-5 code  

Energy Technology Data Exchange (ETDEWEB)

There is a short description of DINAMIKA-5 code and calculation results for some conditions with level drop in the volume of the secondary circuit during RCP disconnection and decrease of feedwater flowrate at NPP units with VVER-1000 reactors. (orig.) (3 refs., 9 figs.).

1993-12-31

294

The concept of power correction techniques and its use in the reactor regulation and protection systems in Indian PHWRs  

International Nuclear Information System (INIS)

Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)

2010-02-01

295

The KCAL VERA 22 GHz calibrator survey  

CERN Document Server

We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.

2011-01-01

296

On the problem of magnitude calibration of palaeoearthquakes  

British Library Electronic Table of Contents (United Kingdom)

Some factors affecting the accuracy of magnitude calibration of palaeoearthquakes are discussed. The general problem is illustrated by two case studies. First, the 2003 strong earthquake in the Altai region (Russia-Mongolia border), which has generated co-seismic surface faulting is considered. An analysis is conducted to determine how accurately its magnitude could be defined after 2000 years based on surface faulting parameters, retrieved when future palaeoearthquake studies are launched. This example demonstrates that accurate evaluation of magnitude is possible if specific regional seismotectonic features are taken into account and surface faulting parameters are measured over a dense grid. Next, the Muya earthquake that occurred in the Baikal seismic region in 1957 is studied with res...

2011-01-01

297

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

2000-12-01

298

Enamel-Calibrated Lamellar Bone Reveals Long Period Growth Rate Variability in Humans  

British Library Electronic Table of Contents (United Kingdom)

Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...

2011-01-01

299

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].

2005-06-11

300

Demonstration experiments of volume measurement technique for large scale input accountancy tank  

International Nuclear Information System (INIS)

Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)

2000-12-07

301

Comparison of constitutive models for plastic-bonded explosives  

British Library Electronic Table of Contents (United Kingdom)

A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...

2008-01-01

302

Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The ...

2007-07-25

303

An application of UV-derivative spectrophotometry and bivariate calibration algorithm for study of photostability of levomepromazine hydrochloride  

British Library Electronic Table of Contents (United Kingdom)

Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.

2008-01-01

304

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

305

Survey of Radiation Protection Education and Training in Finland in 2003  

Energy Technology Data Exchange (ETDEWEB)

The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...

2004-07-01

306

Difference Antenna Selection and Power Allocation for Wireless Cognitive Systems  

CERN Document Server

In this paper, we propose an antenna selection method in a wireless cognitive radio (CR) system, namely difference selection, whereby a single transmit antenna is selected at the secondary transmitter out of $M$ possible antennas such that the weighted difference between the channel gains of the data link and the interference link is maximized. We analyze mutual information and outage probability of the secondary transmission in a CR system with difference antenna selection, and propose a method of optimizing these performance metrics of the secondary data link subject to practical constraints on the peak secondary transmit power and the average interference power as seen by the primary receiver. The optimization is performed over two parameters: the peak secondary transmit power and the difference selection weight $\\delta\\in [0, 1]$. We show that, difference selection using the ...

2010-01-01

307

Concrete as secondary containment for interior wall embedded waste lines  

International Nuclear Information System (INIS)

Throughout the DOE complex there are numerous facilities that handle hazardous and radioactive waste solutions. Due to the hazardous constituents of the mixed waste, secondary containment of tank systems and their ancillary piping, in accordance with Resource Conservation and Recovery Act, is a concern for such existing facilities. The Idaho Division of Environmental Quality was petitioned in 1990 for an Equivalent Device determination regarding secondary containment of waste lines embedded in interior concrete walls. The petition was granted; however, it expires in 1996. To address the secondary containment issue, additional studies were undertaken. One study verified the hypothesis that an interior wall pipe leak would follow the path of least resistance through the naturally occurring void found below a rigidly supported pipe and pass into an adjacent room where detection could occur, before any significant deterioration ...

1993-08-17

308

Biogenic iron oxyhydroxide formation at mid-ocean ridge hydrothermal vents: Juan de Fuca Ridge  

Energy Technology Data Exchange (ETDEWEB)

Here we examine Fe speciation within Fe-encrusted biofilms formed during 2-month seafloor incubations of sulfide mineral assemblages at the Main Endeavor Segment of the Juan de Fuca Ridge. The biofilms were distributed heterogeneously across the surface of the incubated sulfide and composed primarily of particles with a twisted stalk morphology resembling those produced by some aerobic Fe-oxidizing microorganisms. Our objectives were to determine the form of biofilm-associated Fe, and identify the sulfide minerals associated with microbial growth. We used micro-focused synchrotron-radiation X-ray fluorescence mapping (mu XRF), X-ray absorption spectroscopy (mu EXAFS), and X-ray diffraction (mu XRD) in conjunction with focused ion beam (FIB) sectioning, and highresolution transmission electron microscopy (HRTEM). The chemical and mineralogical composition of an Fe-encrusted biofilm was queried at different spatial scales, and the spatial relationship between primary ...

2008-05-22

309

The benefits of low level radiation  

Energy Technology Data Exchange (ETDEWEB)

The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).

1997-06-01

310

Stimulated radiation of high - current relativistic electron beams  

International Nuclear Information System (INIS)

The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.

1987-01-01

311

VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:  

Science.gov (United States)

0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...

312

Thermal NDE method for thermal spray coatings  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.

1982-01-01

313

Spectral D line of Na-like multicharged ions and phenomenological inclusion of the Lamb shift in the many-electron systems  

International Nuclear Information System (INIS)

Phenomenological accountancy of quanta-electrodynamic corrections by means of introduction into multielectron theory of short-term potential, the parameters whereof are calibrated in such a way that provides for correct reproduction of the Lamb shift of the 1s-orbital energy for a correspondingly selected effective charge is developed by example of d-line of Na-like multicharged ions.

314

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

315

Regulatory experience on safety system instrument uncertainty of Wolsong units  

International Nuclear Information System (INIS)

This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by recording sufficient ...

2001-05-01

316

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

317

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

318

Mission Science Calibration and Validation Plan - SMAP  

Science.gov (United States)

Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...

319

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

320

Ground water modelling in artificial recharge projects  

International Nuclear Information System (INIS)

Decision-making is strongly based on modelling in two of our water supply projects concerning artificial ground water. The model used is a 2-dimensional flow and transport model using the element method. Due to sharp variations in Finnish soils, the modelling process is based on careful and detailed evaluation of basic hydrogeological data before and during model calibration.

1991-05-09

321

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

322

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

323

Colorimetric porous indicator of carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.

1986-03-01

324

Characterization of Adaptive Optics at Keck Observatory  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.

2003-07-24

325

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

326

Applications of Auger spectroscopy and ESCA to the study of thin films formed on metals  

International Nuclear Information System (INIS)

Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.

1979-05-23

327

An ultrasonic goniometer for surface stress measurement  

Science.gov (United States)

An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.

1978-09-01

328

An instrument for measuring spatial and time characteristics of sea agitation in coastal zones  

Energy Technology Data Exchange (ETDEWEB)

Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.

1981-01-01

329

Radiation protection. A guide for scientists and physicians  

International Nuclear Information System (INIS)

This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...

330

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...

2011-01-01

331

Biological effects of electromagnetic radiation in the microwave range  

Energy Technology Data Exchange (ETDEWEB)

The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...

1980-01-01

332

[The indicators of biological age and accelerated aging in liquidators of the consequences of radiation emergency].  

Science.gov (United States)

The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627

2011-01-01

333

The THz Radiation from Undulator  

Science.gov (United States)

The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.

2010-02-03

334

Study of emission of Cerenkov radiation by tachyons  

Energy Technology Data Exchange (ETDEWEB)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.

1983-01-01

335

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

336

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

337

Potential Hazards from Neutrino Radiation at Muon Colliders  

CERN Document Server

High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.

1999-01-01

338

Model of quantum noise of shadow radiation images  

International Nuclear Information System (INIS)

Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems

339

Coherent oscillator radiation  

International Nuclear Information System (INIS)

Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.

1982-04-01

340

The assessment of defects in thin shells subject to secondary stress  

International Nuclear Information System (INIS)

This paper is concerned with the fracture analysis of thin cylindrical shells subject to secondary bending stresses with some degree of elastic follow-up. A P.Y.F.M. failure assessment route is utilised for an initial investigation. Results are presented graphically and indicate the differences obtained by considering the stresses as primary or secondary in nature. The Jsup(*) contour integral is computed from the results of a non-linear finite element analysis of a thermally loaded cracked cylinder. Comparison is made between Jsup(*) and the P.Y.F.M. failure criteria demonstrating the degree of conservatism in the latter. It is observed that LEFM may be appropriate for moderate load levels but that the elastic follow-up of the structure causes enhancement of Jsup(*) for higher loads, at which stage LEFM becomes non-conservative. (orig.).

1981-08-21

341

Searching for the non-gaussian signature of the CMB secondary anisotropies  

CERN Document Server

In a first paper (Forni & Aghanim 1999), we developed several statistical discriminators to test the non-gaussian nature of a signal. These tests are based on the study of the coefficients in a wavelet decomposition basis. In this paper, we apply them in a cosmological context, to the study of the nature of the Cosmic Microwave Background (CMB) anisotropies. The latter represent the superposition of primary anisotropy imprints of the initial density perturbations and secondary ones due to photon interactions after recombination. In an inflationary scenario (standard Cold Dark Matter) with gaussian distributed fluctuations, we study the statistical signature of the secondary effects. More specifically, we investigate the dominant effects arising from the Compton scattering of CMB photons in ionised regions of the Universe: the Sunyaev-Zel'dovich effect of galaxy clusters and the effects of a spatially inhomogeneous re-ionisation of the ...

1999-01-01

342

SIMS imaging studies of the corrosion of alloy 800 and alloy 600 surfaces under secondary side boiler conditions  

Energy Technology Data Exchange (ETDEWEB)

The nickel-rich superalloys Alloy 600 and Alloy 800 have been corroded in mildly alkaline deuterated aqueous conditions typical of secondary coolant circuits in a nuclear power station. The oxide films and substrates of these alloys have been analysed by imaging SIMS depth profiling, which makes it possible to describe elemental distribution in all three dimensions. The measurement of the distribution of the secondary ions NiO[sup -], FeO[sup -] and CrO[sup -] appears useful for detailing the behaviour of nickel, iron and chromium within oxidized phases. The measurement of D[sup -] distribution outlines the extent of oxide hydration. For Alloy 800, evidence of sodium migration into the grain boundaries of the alloy substrate is found. For Alloy 600, no grain boundary sodium ingress can be identified under comparable corrosion conditions. (author).

1992-08-01

343

SIMS imaging studies of the corrosion of alloy 800 and alloy 600 surfaces under secondary side boiler conditions  

International Nuclear Information System (INIS)

The nickel-rich superalloys Alloy 600 and Alloy 800 have been corroded in mildly alkaline deuterated aqueous conditions typical of secondary coolant circuits in a nuclear power station. The oxide films and substrates of these alloys have been analysed by imaging SIMS depth profiling, which makes it possible to describe elemental distribution in all three dimensions. The measurement of the distribution of the secondary ions NiO"-, FeO"- and CrO"- appears useful for detailing the behaviour of nickel, iron and chromium within oxidized phases. The measurement of D"- distribution outlines the extent of oxide hydration. For Alloy 800, evidence of sodium migration into the grain boundaries of the alloy substrate is found. For Alloy 600, no grain boundary sodium ingress can be identified under comparable corrosion conditions. (author).

344

Real-time coordination of secondary voltage control and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper is devoted to the coordination of secondary voltage control and adaptive parameters resetting of the power system stabilizer, in order to increase stability, margins in real time operation. Secondary voltage control and the power system stabilizer are two control loops, which affect the same system parameter on different bases - that parameter is the voltage set-point of the automatic voltage regulator. It was found that their effects were complementary. In that way, through the proper coordination of actions of these two control loops open up a wide range of possibilities for ensuring the stability of bulk power systems in real time. For the establishment of this coordination, an on-line sequential algorithm is proposed which is based on adaptive resetting of the voltage set-point of the automatic voltage regulator and the PSS parameters. The efficiency of the proposed algorithm is confined through simulations on a real-life ...

2002-06-01

345

Nuclear fragmentation of clinical silicon beam  

Energy Technology Data Exchange (ETDEWEB)

Heavy ions used for biomedical studies fragment when they pass through matter. It is known that different fragments cause different types of biological damage. In this paper, results pertaining to differrent kinds of secondary fragments produced by a /sup 28/Si beam at 463 MeV/nucleon in its interaction with nuclear emulsion are presented. It is observed that the production frequencies of secondary fragments are independent of the target. Partial production cross sections and fluences of the secondary fragments are also discussed. The partial production cross sections for different fragments at three lower energy ranges are practically the same within their statistical errors except for the cross section for Li fragments, which is larger by almost a factor of 1.5 at the lowest energy investigated. The dose contributions of the primary Si beam and its components at different points of the Bragg curve are presented for two ...

1985-02-01

346

Experimental demonstration of a trumpet secondary concentrator for the Cummins Power Generation (CPG) 7.5 kW(e) dish-Stirling system  

Energy Technology Data Exchange (ETDEWEB)

A prototype trumpet type nonimaging secondary concentrator has been designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW(e) dish-Stirling system and a preliminary set of operating tests has been carried out. The secondary is 26.7 cm (10.5 in.) deep by about 69 cm (27 in.) wide, and has a geometric concentration of 1.7X. The test units were fabricated from polished copper spinnings, overcoated with vapor deposited aluminum and aluminum oxide layers and are water cooled. The basic design considerations are reviewed, the objectives and test procedures for the experiment are summarized and some preliminary results are presented.

1996-11-01

347

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

Energy Technology Data Exchange (ETDEWEB)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10[sup -15] cm[sup 2] in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).

1994-01-01

348

Electron detachment cross-sections and secondary-electron emission factors for heavy-negative-ion beams  

International Nuclear Information System (INIS)

The properties of negative-ion beams are very important for designing negative-ion apparatus and applications of negative-ion beams, especially, electron detachment cross-sections at the interaction between negative-ion beams and gas particles in the transport system, and secondary-electron emission factors when negative ions are incident on solid surfaces. These properties of negative-ion beams were investigated experimentally as a function of the ion energy under 50 keV. The single electron detachment cross-sections are almost constant in the other of 10"-"1"5 cm"2 in this energy range, but double electron detachment cross-sections increase in proportion to the ion velocity and much smaller than the single one. As for the secondary-electron emission factor, the emission factors for negative-ion beam are found to be larger by 1 than those for positive-ion beams. (author).

1994-01-01

349

Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259  

Energy Technology Data Exchange (ETDEWEB)

The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.

1995-05-12

350

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

352

Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries  

UK PubMed Central (United Kingdom)

Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available

2005-07-09

353

Radiation therapy alone versus radiation therapy and chemotherapy in the management of Hodgkin's disease.  

UK PubMed Central (United Kingdom)

Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available

1990-02-01

354

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

355

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

356

Lagranzheva dinamika kollektivnykh vzaimodejstvij v potokakh diskretnykh izluchatelej. (Lagrange dynamics of collective interactions in flows of discrete radiators).  

Science.gov (United States)

Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...

1989-01-01

357

Are natural radioactive materials dangerous  

International Nuclear Information System (INIS)

The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).

1974-09-23

358

A radiator of electromagnetic waves with a combined shape of generatrices  

British Library Electronic Table of Contents (United Kingdom)

The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.

2008-01-01

359

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. ...

2006-11-13

360

Using ICCD as a fast optical switch to measure harmonic super-radiation from an optical klystron in a storage ring  

International Nuclear Information System (INIS)

An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate

2001-07-01

361

The medical exposures to ionizing radiations, it is a world priority in radiation protection  

International Nuclear Information System (INIS)

The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)

362

Wall thinning trend analyses for secondary side piping of Korean NPPs  

International Nuclear Information System (INIS)

Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the site application feasibility for ...

2003-08-17

363

Unifying evolutionary and thermodynamic information for RNA folding of multiple alignments  

UK PubMed Central (United Kingdom)

Computational methods for determining the secondary structure of RNA sequences from given alignments are currently either based on thermodynamic folding, compensatory base pair substitutions or both....Full Text Available

2008-11-01

364

The causes, consequences, and treatment of left or right heart failure  

UK PubMed Central (United Kingdom)

Chronic heart failure (HF) is a cardiovascular disease of cardinal importance because of several factors: a) an increasing occurrence due to the aging of the population, primary and secondary prevention...Full Text Available

2011-01-01

365

The application of high pH operation to the secondary water chemistry at Genkai Nuclear Power Station  

International Nuclear Information System (INIS)

PWR plants have made efforts to maintain the long-term integrity of the steam generators (SG) by reducing the amount of corrosion products entering the secondary side of the SG. Iron entered the SG can cause several problems: degraded heat conductivity of the SG tubes in locations where iron is deposited, water level oscillations in the SG due to tube support plate hole blockage, and initiation and propagation of inter-granular attacks (IGA) and stress corrosion cracking (SCC). One of the most effective measures, high all-volatile treatment (AVT) chemistry has been applied to actual plants to reduce the flow-accelerated corrosion (FAC) coming from the carbon steel piping. The secondary water chemistry at Genkai NPS 1 and 2 changed, from the Low AVT chemistry to the High AVT chemistry, in November 2006. In this paper, we will describe the results of experiments in applying the use of High pH water in the secondary water ...

2009-02-01

366

Subcellular Localization of Expansin mRNA in Xylem Cells12  

UK PubMed Central (United Kingdom)

Terminal differentiation of many vascular cells involves cell wall changes. Cells first elongate their primary wall, then lay down a lignified secondary wall, which is often followed by digestion of...Full Text Available

2000-06-01

367

Studying the atmosphere of the exoplanet HAT-P-7b via secondary eclipse measurements with EPOXI, Spitzer and Kepler  

CERN Document Server

The highly irradiated transiting exoplanet, HAT-P-7b, currently provides one of the best opportunities for studying planetary emission in the optical and infrared wavelengths. We observe six near-consecutive secondary eclipses of HAT-P-7b at optical wavelengths with the EPOXI spacecraft. We place an upper limit on the relative eclipse depth of 0.055% (95% confidence). We also analyze Spitzer observations of the same target in the infrared, obtaining secondary eclipse depths of 0.098+/-0.017%, 0.159+/-0.022%, 0.245+/-0.031% and 0.225+/-0.052% in the 3.6, 4.5, 5.8 and 8.0 micron IRAC bands respectively. We combine these measurements with the recently published Kepler secondary eclipse measurement, and generate atmospheric models for the day-side of the planet that are consistent with both the optical and infrared measurements. The data are best fit by models with a temperature inversion, as expected from the high incident ...

2009-01-01

368

Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

369

Structure of first- and second-stage mineralized elements in teeth of the sea urchin Lytechinus variegatus  

UK PubMed Central (United Kingdom)

Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass...Full Text Available

2009-12-01

370

Strength and fluoride release characteristics of a calcium fluoride based dental nanocomposite  

UK PubMed Central (United Kingdom)

Secondary caries and restoration fracture remain the two most common problems in restorative dentistry. Release of fluoride ions (F) could be a substantial benefit because F could enrich neighboring...Full Text Available

2008-11-01

371

Simulation of natural circulation in PGV-1000 steam generator  

Energy Technology Data Exchange (ETDEWEB)

The PGV-1000 secondary side natural circulation calculation results for steady-state operational conditions and their analysis using the data of actual NPP circulation investigation are presented. (3 refs., 3 figs., 3 tabs.).

1993-12-31

372

Simulation of natural circulation in PGV-1000 steam generator  

International Nuclear Information System (INIS)

The PGV-1000 secondary side natural circulation calculation results for steady-state operational conditions and their analysis using the data of actual NPP circulation investigation are presented. (3 refs., 3 figs., 3 tabs.).

1992-09-29

373

Sex Differences in Pain and Psychological Functioning in Persons with Limb Loss  

UK PubMed Central (United Kingdom)

Sex differences in pain are frequently reported in the literature. However, less is known about possible sex differences in the experience of pain secondary to a disability. The current study...Full Text Available

2010-01-01

374

Secondary structure formation and DNA instability at fragile site FRA16B  

UK PubMed Central (United Kingdom)

Human chromosomal fragile sites are specific loci that are especially susceptible to DNA breakage following conditions of partial replication stress. They often are found in genes involved in tumorigenesis...Full Text Available

2010-05-01

375

Secondary reactions during CO hydrogenation on zeolite-supported metal catalysts: influence of alkali cations  

Energy Technology Data Exchange (ETDEWEB)

The effect of neutralizing cations on the secondary reactions of the primary products from CO hydrogenation over ion-exchanged zeolite-supported Ru catalysts was investigated using zeolites with different alkali cations (Li/sup +/, Na/sup +/, K/sup +/, Rb/sup +/, Cs/sup +/). The transformation of olefins (propylene and butene) on the zeolites without the metal, under conditions similar to those used for CO hydrogenation, was also studied in order to understand the effect of the various constituents of the support, i.e., the Broensted acid sites generated during catalyst preparation and the alkali cations, on possible secondary reactions of the primary olefinic products. It was established that secondary acid-catalyzed reactions of these primary products can play a major role in shaping product selectivity during CO hydrogenation over zeolite-supported catalysts. Depending on the concentration and the strength of the acid ...

1987-10-01

377

Safety and efficacy of botox injection in alleviating post-operative pain and improving quality of life in lower extremity limb lengthening and deformity correction  

UK PubMed Central (United Kingdom)

BackgroundDistraction osteogenesis is the standard treatment for the management of lower limb length discrepancy of more than 3 cm and bone loss secondary to congenital anomalies,...Full Text Available

378

STIMULATION OF TARSAL RECEPTORS OF THE BLOWFLY BY ALIPHATIC ALDEHYDES AND KETONES  

UK PubMed Central (United Kingdom)

Rejection of eight aldehydes, eight ketones, five secondary alcohols, and 3-pentanol has been studied in the blowfly Phormia regina Meigen. The data agree with results previously reported...Full Text Available

1949-03-20

379

Role of interferon-gamma in interleukin 12-induced pathology in mice.  

UK PubMed Central (United Kingdom)

Interleukin 12 (IL-12) activates natural killer (NK) and T cells with the secondary synthesis and release of interferon-gamma (IFN-gamma) and other cytokines. IL-12-induced organ alterations are reported...Full Text Available

1995-12-01

380

Ranger 8 - NASA - NSSDC - Spacecraft - Details  

Science.gov (United States)

5 days ago... Sun sensors, 2 secondary Sun sensors, and an Earth sensor. ... This continued intermittently until the rocket burn, at which time ... with incoming asymptotic direction at an angle of -13.6 degrees from the lunar equator. ...

381

Primary and secondary structure of the pore-forming peptide of pathogenic Entamoeba histolytica.  

UK PubMed Central (United Kingdom)

A pore-forming peptide is implicated in the potent cytolytic activity of pathogenic Entamoeba histolytica. Using NH2-terminal sequence information of this peptide, the corresponding cDNA was isolated....Full Text Available

1992-10-01

382

ORNL RSIC-18 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

W. Wayne Scott. ABSTRClCT. Primary proton and secondary particle doses (both .... W. Wayne Scott and R. G. Alsmiller, Jr., Comparisons of Results Ob- ...

383

Nano to micro delivery systems: targeting angiogenesis in brain tumors  

UK PubMed Central (United Kingdom)

Treating brain tumors using inhibitors of angiogenesis is extensively researched and tested in clinical trials. Although anti-angiogenic treatment holds a great potential for treating primary and secondary...Full Text Available

384

Multicenter Case-Control Study on Restless Legs Syndrome in Multiple Sclerosis: the REMS Study  

UK PubMed Central (United Kingdom)

Study objectives:To verify the existence of a symptomatic form of restless legs syndrome (RLS) secondary to multiple sclerosis (MS) and to identify possible associated risk factors.Design:Prospective,...Full Text Available

2008-07-01

385

Micturition in conscious rats with and without bladder outlet obstruction: role of spinal alpha 1-adrenoceptors.  

UK PubMed Central (United Kingdom)

1. In normal rats and rats with bladder hypertrophy secondary to outflow obstruction, undergoing continuous cytometry, we examined the responses to the selective alpha 1-adrenoceptor antagonist doxazosin...Full Text Available

1996-03-01

386

Interhemispheric Interactions between the Human Primary Somatosensory Cortices  

UK PubMed Central (United Kingdom)

In the somatosensory domain it is still unclear at which processing stage information reaches the opposite hemispheres. Due to dense transcallosal connections, the secondary somatosensory cortex (S2)...Full Text Available

387

Infective arthritis secondary to bladder outflow obstruction.  

UK PubMed Central (United Kingdom)

We describe two cases of septic arthritis occurring in association with lower urinary tract infection in elderly men. In both cases the organism isolated from both the joint and the urine was Staphylococcus...Full Text Available

1990-12-01

388

Indole-Diterpene Gene Cluster from Aspergillus flavus  

UK PubMed Central (United Kingdom)

Aflatrem is a potent tremorgenic mycotoxin produced by the soil fungus Aspergillus flavus and is a member of a large structurally diverse group of secondary metabolites known as indole-diterpenes....Full Text Available

2004-11-01

389

Illthrift in Suckling Lambs Secondary to Umbilical Infections and Possible Implication of Cryptosporidiosis as a Risk Factor  

UK PubMed Central (United Kingdom)

Illthrift was observed in 20/60 lambs aged 40–45 days in a dairy sheep flock in Greece. Cryptosporidiosis had been diagnosed and successfully treated with halofuginone lactate a month earlier....Full Text Available

390

Harnessing the geothermal resources of sedimentary basins for electricity production  

Science.gov (United States)

Use of geothermal resources for generating electricity is briefly analyzed. Results obtained from optimization of the thermodynamic cycle implemented in the secondary coolant circuit of a binary geothermal power station and the parameters of its primary heat carrier circuit are presented.

2011-02-01

391

Green primary explosives: 5-Nitrotetrazolato-N2-ferrate hierarchies  

UK PubMed Central (United Kingdom)

The sensitive explosives used in initiating devices like primers and detonators are called primary explosives. Successful detonations of secondary explosives are accomplished by suitable sources of...Full Text Available

2006-07-05

392

Five year prospective study of plasma renin activity and blood pressure in patients with longstanding reflux nephropathy.  

UK PubMed Central (United Kingdom)

Eight of 100 normotensive children who had pyelonephritic scarring secondary to urinary infection and vesicoureteric reflux were found in an earlier study to have increased plasma renin activity (PRA)....Full Text Available

1987-07-01

393

FFTF reactor assembly system technology  

Science.gov (United States)

An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs. (DG)

1975-11-13

394

FFTF reactor assembly system technology  

International Nuclear Information System (INIS)

An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs.

1976-03-13

395

Evidence of perturbations of cell cycle and DNA repair pathways as a consequence of human and murine NF1-haploinsufficiency  

UK PubMed Central (United Kingdom)

BackgroundNeurofibromatosis type 1 (NF1) is a common monogenic tumor-predisposition disorder that arises secondary to mutations in the tumor suppressor gene NF1....Full Text Available

396

Evaluation of the Hip: History and Physical Examination  

UK PubMed Central (United Kingdom)

Examination of a painful hip is fairly concise and reliable at detecting the presence of a hip joint problem. Hip joint disorders often go undetected, leading to the development of secondary disorders....Full Text Available

2007-11-01

397

Endovascular treatment of a Superior Mesenteric Artery Syndrome variant secondary to traumatic pseudoaneurysm  

UK PubMed Central (United Kingdom)

Pseudoaneurysms related to the superior mesenteric artery (SMA) are a recognised complication of trauma to the vessel, and successful treatment with stenting has been previously described. We report...Full Text Available

398

Endothelin-1 Is Increased in Cerebrospinal Fluid and Associated with Unfavorable Outcomes in Children after Severe Traumatic Brain Injury  

UK PubMed Central (United Kingdom)

AbstractSevere pediatric traumatic brain injury (TBI) is associated with unfavorable outcomes secondary to injury from activation of the inflammatory cascade, the release of excitotoxic...Full Text Available

2010-10-01

399

Electrochemical Processes : Lecture Notes for a course in Applied Inorganic Chemistry  

DEFF Research Database (Denmark)

The notes describe in detail primary and secondary galvanic cells, fuel cells, electrochemical synthesis and electroplating processes, corrosion: measurments, inhibitors, cathodic and anodic protection, details of metal dissolution reactions, Pourbaix diagrams and purification of waste water from galvanic industries.

1997-01-01

400

Education and the Economy: The External Efficiency of Education. Educational Policy and Planning Project.  

Science.gov (United States)

External inefficiency in education--inequity between the characteristics of graduates and the job market--is a problem in Indonesia and many other countries. Job markets at the junior secondary level are very tight in Indonesia with low levels of unemployment at all ages, short job-search times, and high real rates of return. Unemployment, however, among the senior secondary vocational and senior secondary general school graduates is high, even though the real rates of return are also high. The same is true for college and university graduates. Rates decrease, however, as years pass after graduation. There are several reasons for this external inefficiency: underinvestment in secondary education, increased use of market signals for planning and annual budgeting decisions, excess"social demand" for higher education and insufficient resource recovery, inaccurate selection criteria, and inadequate ...

1991-12-01

401

Distribution Frequency of Pathogenic Bacteria Isolated from Cutaneus Leishmaniasis Lesions  

UK PubMed Central (United Kingdom)

Cutaneous leishmaniasis (CL) is a parasitic disease characterized by single or multiple ulcerations. Secondary bacterial infections are one of the complications that can increase the tissue destruction...Full Text Available

2008-09-01

402

DESIGN MANUAL: SWIRL AND HELICAL BEND POLLUTION CONTROL DEVICES  

Science.gov (United States)

This design manual contains descriptions of design procedures and operating experience to date, including results obtained, for secondary flow pollution control devices. Two types of combined sewer overflow regulators are described: the swirl and the helical bend regulator/separa...

403

Continuity of Care with a Primary Care Physician and Mortality in Older Adults  

UK PubMed Central (United Kingdom)

BackgroundWe examined whether older adults who had continuity of care with a primary care physician (PCP) had lower mortality.MethodsSecondary analyses...Full Text Available

2010-04-01

404

Comparing the Diagnostic Performance of 2 Clinical Decision Rules to Rule Out Deep Vein Thrombosis in Primary Care Patients  

UK PubMed Central (United Kingdom)

PURPOSE The Wells rule is widely used for clinical assessment of patients with suspected deep vein thrombosis (DVT), especially in the secondary care setting. Recently a new clinical decision...Full Text Available

2011-01-01

405

Characterization of ?-Butyrolactone Autoregulatory Signaling Gene Homologs in the Angucyclinone Polyketide WS5995B Producer Streptomyces acidiscabies?  

UK PubMed Central (United Kingdom)

Organisms belonging to the genus Streptomyces produce numerous important secondary metabolites and undergo a sophisticated morphological differentiation program. In many instances these...Full Text Available

2009-08-01

406

Bladder outlet obstruction in a 6-month-old alpaca secondary to pelvic displacement of the urinary bladder  

UK PubMed Central (United Kingdom)

AbstractA 6-month-old female alpaca was presented for stranguria. Based on the history, physical examination findings, and radiographic studies, the alpaca was diagnosed with bladder...Full Text Available

2005-03-01

407

Biogenic carbon and anthropogenic pollutants combine to form a cooling haze over the southeastern United States  

UK PubMed Central (United Kingdom)

Remote sensing data over North America document the ubiquity of secondary aerosols resulting from a combination of primary biogenic and anthropogenic emissions. The spatial and temporal distribution...Full Text Available

2009-06-02

408

Betaxanthins as Substrates for Tyrosinase. An Approach to the Role of Tyrosinase in the Biosynthetic Pathway of Betalains1  

UK PubMed Central (United Kingdom)

Tyrosinase or polyphenol oxidase (EC 1.14.18.1) is the key enzyme in melanin biosynthesis and in the enzymatic browning of fruits and vegetables. The role of tyrosinase in the secondary metabolism of...Full Text Available

2005-05-01

409

Beam collimator  

CERN Document Server

A four-block collimator installed on a control table for positioning the alignment reference marks. Designed for use with SPS secondary beams, the collimator operates under vacuum conditions. See Annual Report 1976 p. 121 and photo 7701014.

1977-01-01

410

Albumin binding of photobilirubin II.  

UK PubMed Central (United Kingdom)

Photobilirubin II, a stereoisomer of bilirubin, binds to human serum albumin at a single binding site (K = 2.2 x 10(6)M-1), presumably the high-affinity bilirubin-binding site. Binding in the secondary...Full Text Available

1983-07-01

411

A study in molecular contingency: glutamine phosphoribosylpyrophosphate amidotransferase is a promiscuous and evolvable phosphoribosylanthranilate isomerase  

UK PubMed Central (United Kingdom)

SummaryThe prevalence of paralogous enzymes implies that novel catalytic functions can evolve on preexisting protein scaffolds. The weak secondary activities of proteins, which...Full Text Available

2008-03-21

412

A hypothetical model for the peptide binding domain of hsp70 based on the peptide binding domain of HLA.  

UK PubMed Central (United Kingdom)

The sequences of the peptide binding domains of 33 70 kd heat shock proteins (hsp70) have been aligned and a consensus secondary structure has been deduced. Individual members showed no significant...Full Text Available

1991-05-01

413

A Patchy Growth via Successive and Simultaneous Cambia: Key to Success of the Most Widespread Mangrove Species Avicennia marina?  

UK PubMed Central (United Kingdom)

Background and AimsSecondary growth via successive cambia has been intriguing researchers for decades. Insight into the mechanism of growth layer formation is, however, limited to...Full Text Available

2008-01-01

414

Sensitivity analysis and development of calibration methodology for near-surface hydrogeology model of Laxemar  

Energy Technology Data Exchange (ETDEWEB)

This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE ...

2007-11-15

415

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...

2001-06-17

416

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

417

VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...  

Science.gov (United States)

Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...

418

Treatment of persons exposed in radiation accidents or nuclear explosions. Omhaendertagande av skadade vid radiakolyckor och kaernvapenexplosioner  

Energy Technology Data Exchange (ETDEWEB)

The report gives general principles of treatment and care of casualties caused by radiation accidents or nuclear explosions.

1991-01-01

419

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

421

Tachyon Cerenkov radiation  

Energy Technology Data Exchange (ETDEWEB)

By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.

1985-09-01

422

Solar Cell Radiation Response near the Interface of Different ...  

Science.gov (United States)

... Solar Cell Radiation Respinnse Near the Interface o~f fliffprerv- ... 5 4. CALCUTl-ATED SOLAR CELL RLSPONSE FOR VARIOUS BASE MATERIALS ...

1971-11-01

423

Relationship of Optical Coating on Thermal Radiation ...  

Science.gov (United States)

drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...

424

References | Radiation Protection | US EPA  

Wastenet

...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...

425
426

Radiation deamination of tetracycline. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.

1980-01-01

427

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compounds in EBR-II and FFTF  

Energy Technology Data Exchange (ETDEWEB)

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF

1999-05-01

428

Onclas U9800 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

the probability of its spontaneous radiation de-excitation increases. ... consider spontaneous radiation transitions. We will examine the ...

429

Numerical analysis of methane-air combustion considering radiation effect  

Energy Technology Data Exchange (ETDEWEB)

Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to ...

2008-12-15

430

Numerical analysis of methane-air combustion considering radiation effect  

International Nuclear Information System (INIS)

Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the ...

2008-12-01

431

Multifunctional, Boron-Foam Based Radiation Shielding  

Science.gov (United States)

PROPOSAL NUMBER: 04 B3.09-7744. SUBTOPIC TITLE: Radiation Shielding to Protect Humans. PROPOSAL TITLE: Multifunctional, Boron-Foam Based ...

432

Mathematical Analysis of Three Free-Electron-Laser Issues  

Science.gov (United States)

... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...

1990-09-30

433

Equipment hardening and hardness assurance  

International Nuclear Information System (INIS)

The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...

434

Enhanced coherent undulator radiation from bunched electron beams  

International Nuclear Information System (INIS)

When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...

1995-09-28

436

ESR study in radiation damage in pyrimidines. 3-year comprehensive progress report  

International Nuclear Information System (INIS)

General mechanisms of radiation damage to biomolecules was studied by using substituted pyrimidines, particularly barbituric acid derivatives.

437

Differences in synchrotron radiation induced gas desorption from stainless steel and aluminium alloy  

CERN Document Server

Differences in synchrotron radiation induced gas desorption from stainless steel and aluminium alloy

1990-01-01

438

Combined Radiation and Thermal Injury after Nuclear Attack  

Science.gov (United States)

... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...

2011-05-13

439

Chinese Journal of Lasers (Selected Articles)  

Science.gov (United States)

... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...

1991-12-10

440

An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors  

UK PubMed Central (United Kingdom)

PurposeTo evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors.Methods...Full Text Available

2008-04-01

441

Vascular injuries in intestinal obstruction. The role of computed tomography; Complicazioni vascolari nelle occlusioni intestinali: ruolo della tomografia computerizzata  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates computerized tomography capabilities in showing vascular complications secondary to intestinal obstruction and for assessing the site and cause of obstruction. [Italian] Scopo del lavoro e' lo studio dell'uso della tomografia computerizzata nel riconoscimento di complicanze vascolari secondarie ad occlusione intestinale e della presenza, della natura e della sede dell'ostacolo alla canalizzazione intestinale.

1999-09-01

442

Use of a new time of flight aerosol mass spectrometer for ground and airborne measurements of biogenically produced organic aerosols  

Environmental Research Database

DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...

443

The use of lead isotopic abundances in trace uranium samples for nuclear forensics analysis  

International Nuclear Information System (INIS)

Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)

2010-06-01

444

Study of Single W production in e-gamma collisions through the decay lepton spectrum to probe gamma-WW couplings  

CERN Document Server

We investigate the effect of anomalous gamma-W-W couplings in e-gamma --> nu W through the angular and energy spectrum of the secondary leptons. Within the narrow-width approximation, a semi-analytical study of the secondary lepton energy-angle double distribution is considered. Utility of observables derived from this is demonstrated by considering the anomalous coupling, delta-kappa-gamma. Results of our investigation for typical ILC machine considered at Ecm = 300-1000 GeV re-affirms potential of this collider as a precision machine.

2011-01-01

445

Steam generator tube performance  

International Nuclear Information System (INIS)

A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.

2005-10-27

446

Similarity between the primary and secondary air-assisted liquid jet breakup mechanism  

CERN Document Server

we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.

2007-01-01

447

Safe hole trapping, light soaking and secondary photocurrent transients in amorphous silicon  

International Nuclear Information System (INIS)

A new analysis is developed for long secondary photocurrent transients which gives the distribution of trapped holes in valence band tail states. Thermally assisted tunneling to dangling bonds is implicated as the rate limiting step in hole-recombination. Light-soaking causes the energetically deeper hole traps with the longer residence times to be lost first and in the same number as would be expected for the increase in dangling bonds; This result supports a model which has hole trapping in valence tail states as a precursor to light induced dangling bonds.

1988-09-26

448

PAMELA results on the cosmic-ray antiproton flux from 60 MeV to 180 GeV in kinetic energy  

CERN Document Server

The satellite-borne experiment PAMELA has been used to make a new measurement of the cosmic-ray antiproton flux and the antiproton-to-proton flux ratio which extends previously published measurements down to 60 MeV and up to 180 GeV in kinetic energy. During 850 days of data acquisition approximately 1500 antiprotons were observed. The measurements are consistent with purely secondary production of antiprotons in the galaxy. More precise secondary production models are required for a complete interpretation of the results.

2010-01-01

449

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

450

Evidence-Based Drainage of Infected Hydronephrosis Secondary to Ureteric Calculi  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction: The obstructed, infected kidney is a urological emergency. It has been accepted that the management of infected hydronephrosis secondary to ureteric stones is through prompt decompression of the collecting system. However, the optimal method of decompression has yet to be established. Materials and Methods: A PubMed and Medline search was performed of all English-language articles from 1960 using key words ?sepsis,?? ?urosepsis,?? ?obstruction,?? ?obstructive pyelonephritis,?? ?pyonephrosis,?? ?infection and hydronephrosis?? ?decompression,?? ?stent,?? ?nephrostomy,?? and ?management.?? The Cochrane database and National Institute for Clinical Effectiveness guidelines were searched using the terms ?sepsis,?? ?urosepsis,?? ?stent,?? ?nephrostomy,?? or ?obstruction.?? ...

2010-01-01

451

Esterification of chiral secondary alcohols with fatty acid in organic solvents by polyethylene glycol-modified lipase.  

Science.gov (United States)

Lipase from Pseudomonas fragi 22.39B was modified with polyethylene glycol. The modified lipase (PEG-lipase) was soluble and active in organic solvents such as benzene and 1,1,1-trichloroethane. PEG-lipase catalyzed esterification of chiral secondary alcohols with fatty acids in benzene and exhibited preference for R isomers over S isomers. Km and Vmax values for each isomer of various alcohols were obtained by kinetic study of the esterification in benzene. PEG-lipase-catalyzed esterification leads to optical resolution of a racemic alcohol. PMID:2635854

1989-11-01

452

Construction: Masonry. Secondary Schools. Curriculum Guide.  

Science.gov (United States)

This construction curriculum guide on masonry for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of instruction; and a listing of references. Concepts covered include orientation to masonry construction, safety, tools and equipment, cement, concrete, concrete block masonry, concrete forms, and concrete reinforcement. Appended materials include transparency copies, tests and answer keys, information sheets, and student activities. (CT)

1980-08-01

453

Acute lymphoblastic leukemia with multiple cytogenetic abnormalities secondary to treatment of Ewing's sarcoma  

International Nuclear Information System (INIS)

We report the case of a 22-year-old man with Ewing's sarcoma who attained a complete remission (CR) after combination radiotherapy and chemotherapy. Secondary acute lymphoblastic leukemia with multiple cytogenetic abnormalities involving chromosome 5 and 7 developed 16 years later. The patient underwent induction chemotherapy and entered a CR. Peripheral blood stem cell transplantation from a matched sibling was performed successfully and he is in complete remission of both ALL and Ewing's sarcoma. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

1999-06-01

454

West Siberian basin hydrogeology - regional framework for contaminant migration from injected wastes  

Energy Technology Data Exchange (ETDEWEB)

Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...

1994-05-01

455

Using calibrated engineering models to predict energy savings in large-scale geothermal heat pump projects  

Energy Technology Data Exchange (ETDEWEB)

Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...

1998-10-01

456

Using Calibrated Engineering Models To Predict Energy Savings In Large-Scale Geothermal Heat Pump Projects  

Energy Technology Data Exchange (ETDEWEB)

Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...

1998-01-01

457

Type Ia supernova science 2010-2020  

CERN Document Server

In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0

2009-01-01

458

The design and performance of a capacitance sensor for two-phase flow concentration measurements in a square duct  

Energy Technology Data Exchange (ETDEWEB)

The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...

1995-12-31

459

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...

2009-09-14

460

Simultaneous determination of dorzolamide HCL and timolol maleate in eye drops by two different spectroscopic methods.  

Science.gov (United States)

Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical ...

2002-04-15

461

Quantification of the local glucose utilization and local blood flow in the heart of the awake rat using the /sup 14/C-2-deoxyglucose and /sup 14/C-iodoantipyrine methods  

Science.gov (United States)

Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.

1986-03-05

462

Method of calibration to correct for cloud-induced wavelength shifts in the Aura satellite's Ozone Monitoring Instrument  

Science.gov (United States)

The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these ...

2006-05-01

463

Life Under Your Feet: An End-to-End Soil Ecology Sensor Network, Database, Web Server, and Analysis Service  

CERN Document Server

Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. However, the deployment required device-level programming, sensor ...

2007-01-01

464

Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...

1978-04-01

465

Determination of binary mixtures of analgesic and spasmolytic drugs in pure and dosage forms by derivative spectrophotometry.  

Science.gov (United States)

Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values were calculated. The developed derivative spectrophotometric methods were applied to laboratory mixtures and to vials for ...

2003-10-15

466

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers  

Energy Technology Data Exchange (ETDEWEB)

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a ...

2008-01-16

467

BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...

2007-08-01

468

Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma  

Energy Technology Data Exchange (ETDEWEB)

In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...

2009-07-15

469

Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma  

International Nuclear Information System (INIS)

In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...

2009-07-01

470

A proposed methodology for computational fluid dynamics code verification, calibration, and validation  

Energy Technology Data Exchange (ETDEWEB)

Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...

1995-07-01

474

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

476

Solar Radiation Pressure Binning for the Geosynchronous Orbit  

Science.gov (United States)

Orbital maintenance parameters for individual satellites or groups of satellites have traditionally

2011-01-01

477

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

478

Radiological equipment for emergencies  

Energy Technology Data Exchange (ETDEWEB)

A brief guide to training and equipment needed to effectively manage victims of radiation accidents. (DT)

1985-01-01

479

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).

480

Radiation Protection of the Organism (Selected Chapters)  

Science.gov (United States)

... biologically important compounds is sharply lowered with passage of the solutions to the cell an organ, where their sensitivity ...

1970-12-11

481
483

Kinetics of low-temperature radiation hardening of metallic materials under irradiation  

British Library Electronic Table of Contents (United Kingdom)

A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.

2011-01-01

485

Induced radiation during scattering of channeled electrons and positrons by point defects  

Energy Technology Data Exchange (ETDEWEB)

In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.

1984-12-01

488

Experts' discussion on the possibility of quantification of the radiation hazard  

International Nuclear Information System (INIS)

Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).

1978-01-01

489

Effective dose equivalent in nuclear medicine investigations  

International Nuclear Information System (INIS)

... radiation hazards hazards health hazards MEDICINE. SOMATICALLY

1984-05-07

492

Cooperative spontaneous emission from two different atoms  

International Nuclear Information System (INIS)

The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).

1986-01-01

493

Cluster-loop structure influence on molybdenum radiation hardening  

International Nuclear Information System (INIS)

Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).

1990-05-22

497

About tachyons  

International Nuclear Information System (INIS)

... Part A: The electromagnetic radiation of a charged tachyon. Part B: Some