WorldWideScience
1

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV ...

1993-01-01

2

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

3

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

4

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

5

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

6

The preliminary success of ALARA implementation in Daya Bay NPP  

International Nuclear Information System (INIS)

Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant ...

2000-05-01

7

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

8

Domestic radon exposures in the UK  

Energy Technology Data Exchange (ETDEWEB)

Radon in the home is the main source of exposure to ionising radiation for most people. In 1990 the National Radiological Protection Board issued revised advice to the United Kingdom Government on standards of protection against radon in the home. A description is offered of the survey work being undertaken by the Board which includes radiation measurements of thousands of homes in the United Kingdom. (author).

1991-09-01

9

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

10

Assessment and control of fetal exposure  

Energy Technology Data Exchange (ETDEWEB)

The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the ...

1991-10-01

11

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration ...

2008-11-19

12

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

14

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

15

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

16

Weakly penetrating radiation monitoring and assessment at Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)

2006-05-01

18

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

19

References | Radiation Protection | US EPA  

Wastenet

...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...

20

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

21

Computer simulation and radiation hardening of power devices to protect against failures induced by heavy ions  

International Nuclear Information System (INIS)

Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).

22

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

23

Survey of Radiation Protection Education and Training in Finland in 2003  

Energy Technology Data Exchange (ETDEWEB)

The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and ...

2004-07-01

24

ESR spectra of radicals of gamma-irradiated wood and cellulose  

International Nuclear Information System (INIS)

Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.

25

Radiation Protection of the Organism (Selected Chapters)  

Science.gov (United States)

... biologically important compounds is sharply lowered with passage of the solutions to the cell an organ, where their sensitivity ...

1970-12-11

26

CRC handbook of management of radiation protection programs  

Energy Technology Data Exchange (ETDEWEB)

This guidebook organizes the profusion of rules and regulations surrounding radiation protection into a single-volume reference. Employee and public protection, accident prevention, and emergency preparedness are included in this comprehensive coverage. Whenever possible, information is presented in convenient checklists, tables, or outlines that enable you to locate information quickly.

1986-01-01

27

Influence of weather on the behaviour of outdoor-wintered beef cattle in Scandinavia  

British Library Electronic Table of Contents (United Kingdom)

The aim of the present investigation was to study the effect of weather and available protection on the behaviour of outdoor-wintered beef cattle (Bos taurus). A herd of 78-85 cattle head was studied during four winter months in the Southwest of Sweden. Protection was offered by coniferous forest situated on and around the 12ha pasture, which we divided into protection categories. During 240h we observed 10 cows and 10 heifers as focal animals (each 3h/month) during day time and adjusted observation times to the altitude of the sun. Close to the animals and at an unprotected spot of the pasture we measured temperature, wind speed and solar radiation and combined these variables to a single measure called Wind Chill Temperature (WCT). During observations the animals were in the forest in 12...

2011-01-01

28

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

29

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

30

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including ...

31

Distributed radiation protection console system  

International Nuclear Information System (INIS)

Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire ...

2004-02-01

32

The NCRP wound model: development and application.  

Science.gov (United States)

The US National Council on Radiation Protection and Measurements, in collaboration with the International Commission on Radiological Protection, has been developing a biokinetic and dosimetric model for radionuclide-contaminated wounds. The finalised model is described briefly in this paper, together with the scientific basis and application. The multicompartment model uses first-order linear biokinetics to describe the retention and clearance of a radionuclide deposited in a wound site using seven default retention categories. Examples using plutonium nitrate in colloidal form and uranium in metal fragments show the behaviour of the less soluble forms of radionuclides in wounds, in which long-term retention is predicted. Using uranium as an example, the wound model is coupled to a uranium International Commission on Radiological Protection systemic model to predict urinary ...

2007-08-31

33

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

34

Occupational exposure information system in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)

2005-07-01

35

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

36

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

37

Practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc

2004-05-01

38

Multifunctional, Boron-Foam Based Radiation Shielding  

Science.gov (United States)

PROPOSAL NUMBER: 04 B3.09-7744. SUBTOPIC TITLE: Radiation Shielding to Protect Humans. PROPOSAL TITLE: Multifunctional, Boron-Foam Based ...

39

Survey of radiation protection programmes for transport; Etude des programmes de radioprotection pour les transports de matieres radioactives  

Energy Technology Data Exchange (ETDEWEB)

The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)

2001-07-01

40

222Rn exhalation rate from Egyptian building materials using active and passive methods  

International Nuclear Information System (INIS)

... Sciences, Research Center for Radiation Protection, Chiba (Japan) Hafez,

2009-03-01

41

Ultraviolet-B Phototoxicity and Hypothetical Photomelanomagenesis: Intraocular and Crystalline Lens Photoprotection  

British Library Electronic Table of Contents (United Kingdom)

Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...

2010-01-01

42

Proposal of a system of signalling of security in occupational radiological protection for radiactives and nuclear installations  

International Nuclear Information System (INIS)

After five years of implantation of a program for classification and signalling of restricted areas in the IPEN-CNEN-SP, we noticed that the applied measures of radio protection contributed for the improvement of the system of occupational radiological protection, promoting an improvement in the security of the workers, towards the planning in the execution of the activities involving the use of sources of ionizing radiation. Later, during the implantation of this program, the service of occupational radiological protection, there was great difficulty to conciliate its necessities in terms of security signalling, face the absence of existing standardisation in the country for the minimum disposals on the subject in question. Nowadays there are different interpretations of the specific criteria and many effective normative documents that exist in the country. This work presents as ...

43

Radiation protection. A guide for scientists and physicians  

International Nuclear Information System (INIS)

This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed ...

44

Radiation protection  

International Nuclear Information System (INIS)

The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In ...

1988-01-01

45

Environmental Radiation Effects: A Need to Question Old Paradigms  

Energy Technology Data Exchange (ETDEWEB)

A historical perspective is given of the current paradigm that does not explicitly protect the environment from radiation, but instead, relies on the concept that if dose limits are set to protect humans then the environment is automatically protected as well. We summarize recent international questioning of this paradigm and briefly present three different frameworks for protecting biota that are being considered by the U.S. DOE, the Canadian government and the International Commission on Radiological Protection. We emphasize that an enhanced collaboration is required between what has traditionally been separated disciplines of radiation biology and radiation ecology if we are going to properly address the current environmental radiation problems. We then summarize results generated from an EMSP ...

2003-03-27

46

Development of radiological emergency preparedness and biological dosimetry technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological ...

1999-04-01

47

The summarize of the technique about proactive network security protection  

International Nuclear Information System (INIS)

The proactive protection measures and the traditional passive security protection tools are complementarities each other. It also can supply the conventional network security protection system and enhance its capability of the security protection. Based upon sorts of existing network security technologies, this article analyses and summarizes the technologies, functions and the development directions of some key proactive network security protection tools. (authors)

2003-09-08

48

Performance evaluation of the conventional Brazilian industries radiation protection in the small industrial gauges and industrial radiography areas; Sistema de avaliacao de desempenho em radioprotecao das industrias convencionais brasileiras nas areas de medidores nucleares e radiografia industrial  

Energy Technology Data Exchange (ETDEWEB)

This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that ...

1999-08-01

49

Measurement of magnetic fields in the Area Metropolitana  

International Nuclear Information System (INIS)

The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which ...

51

Different techniques for measuring radon concentration in a spa environment  

International Nuclear Information System (INIS)

In the context of radiation protection for both workers and the population in general, natural sources of radiation, and in particular radon gas and its short-life decay products assume great importance. In particular, workers in thermal spas can easily be exposed to a level of radon radiation and its decay products comparable to those in uranium mines, though often these workers are unaware of the danger. The main source of radon in thermal baths is the thermal water itself, coming as it often does from deep springs, and this can produce high radon concentrations which are left in those areas in which therapy is carried out. Another factor which cannot be overlooked is the radioactive content of thermal mud, often matured for long periods by contact with thermal water. Thermal cures, though varying slightly from site to site, consist principally of mud cures, hydro-therapy and inhalation in various ...

2002-10-08

52

Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries  

UK PubMed Central (United Kingdom)

Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available

2005-07-09

53

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

54

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing ...

2009-03-01

55

Hanford Internal Dosimetry Program Manual, PNL-MA-552  

Energy Technology Data Exchange (ETDEWEB)

This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

2009-09-24

56

The radon therapy - radon inhalatorium in Kowary  

International Nuclear Information System (INIS)

In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)

57

Microwaves (including RADAR) and radiation protection  

Energy Technology Data Exchange (ETDEWEB)

The Commission of the European Communities has submitted a directive for the protection against microwaves. According to this directive, exposures above the upper limit established for the protection of individuals and the general population are permissible only if the respective individuals are required to submit to occupational medical control. An introductory overview is presented giving information on microwaves, applied techniques and available protective means.

1981-02-01

58

Experience in implementing the idea of work management in radiation practices in Daya Bay NPP  

International Nuclear Information System (INIS)

The philosophy of work management in radiation protection puts emphasis on the following up and management of overall process from work selection, planning, preparation, implementation till experience feedback, and overall optimization of production and safety management. This paper reports practices and experiences of Daya Bay nuclear power plant in the implementation of the philosophy during operational radiation protection through the practical examples

2004-05-01

59

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

60

Biological Research for Radiation Protection  

International Nuclear Information System (INIS)

The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect ...

61

Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection  

Energy Technology Data Exchange (ETDEWEB)

To determine if barbiturates would protect brain at high doses of radiation, survival rates in rats that received whole-brain x-irradiation during pentobarbital- or lidocaine-induced anesthesia were compared with those of control animals that received no medication and of animals anesthetized with ketamine. The animals were shielded so that respiratory and digestive tissues would not be damaged by the radiation. Survival rates in rats that received whole-brain irradiation as a single 7500-rad dose under pentobarbital- or lidocaine-induced anesthesia was increased from between from 0% and 20% to between 45% and 69% over the 40 days of observation compared with the other two groups (p less than 0.007). Ketamine anesthesia provided no protection. There were no notable differential effects upon non-neural tissues, suggesting that pentobarbital afforded protection through modulation of ...

1990-05-01

62

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work ...

2006-01-01

63

Status of safety at Areva group facilities. 2007 annual report; Areva, etat de surete des installations nucleaires. Rapport annuel 2007  

Energy Technology Data Exchange (ETDEWEB)

This report describes the status of nuclear safety and radiation protection in the facilities of the AREVA group and gives information on radiation protection in the service operations, as observed through the inspection programs and analyses carried out by the General Inspectorate in 2007. Having been submitted to the group's Supervisory Board, this report is sent to the bodies representing the personnel. Content: 1 - A look back at 2007 by the AREVA General Inspector: Visible progress in 2007, Implementation of the Nuclear Safety Charter, Notable events; 2 - Status of nuclear safety and radiation protection in the nuclear facilities and service operations: Personnel radiation protection, Event tracking, Service operations, Criticality control, Radioactive waste and effluent management; 3 - Performance ...

2007-07-01

64

Hypoxia and Magnetic Therapy for Personnel Radiation Protection  

International Science & Technology Center (ISTC)

Development of Portable Normobaric Hypoxia and Pulsed Magnetic Field Firmware System for Enhancement of Radio- and Non-specific Resistance in Workers of Environmentally Hazardous Industries

65

Shield-verification survey of a large hot cell at the FFTF  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.

1980-01-01

66

Radiation risks for medical applications  

International Nuclear Information System (INIS)

The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).

1980-05-31

67

Risk assessment for radiation protection purposes  

International Nuclear Information System (INIS)

In defining criteria for good protection against ionizing radiation, it is important to assess quantitatively the likely risk of any radiation exposure. The 'somatic' risks to the individual result mainly from induction of cancer in the organs irradiated, and these risks can now be estimated on the basis of numerous detailed epidemiological surveys of exposed human populations. Estimates of the risk of hereditary effects, from genetic changes induced in germ cells, are based largely on the frequency with which such effects are induced in other species. In both cases the risk at very low dose can be inferred using knowledge of the way in which radiation damage is caused in tissues. Coherent systems of radiation protection are based on a restriction of doses to the whole body and to individual organs, such that the induction of cancer and genetic harm is ...

1980-01-01

69

A.C.R.O. activity report 2002; A.C.R.O. rapport d'activite 2002  

Energy Technology Data Exchange (ETDEWEB)

A.C.R.O. (Association pour le Controle de la Radioactivite dans l Ouest) is a French non governmental organisation that operates a laboratory for radioactivity analysis. It was created in 1986 as a response to people demands for information and reliable, independent testing. The organisation mainly carries out missions of information and training for its correspondents and more generally for a wide audience, particularly for people who worry about problems of environment, health, management of radioactive waste and emissions. Thanks to its structure, it enables citizens to involve themselves together with scientists so as to gain access to information that was hither to reserved to specialists. The organisation can vouchsafe its independence from the diversity of its members and volunteers, as well as from the diversity of its money resources. Besides its headquarters situated on the city of Caen area (Normandy), three branches situated in North Normandy, in Touraine and North Cotentin ...

2002-07-01

70

A study on the anodic protection of titanium evaporators in Al[sub 2](SO[sub 4])[sub 3] solution  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of the anodic protection of titanium evaporators in Al[sub 2](SO[sub 4])[sub 3] solution was studied by the measurement of polarization curves, weight loss, solubility of passive film and AC impedance. The protection parameters and efficiency were determined. In addition, the practical technology of anodic protection was studied by screening reference electrodes and auxiliary cathodes. Throwing power was also measured. Four rows of tube-type evaporators of titanium have been anodically protected in situ. Field tests lasting more than one year shows satisfactory results. (orig.)

1993-07-01

71

Surgical adjuvant therapy in colon carcinoma: a human tumor spheroid model for evaluating radiation sensitizing agents  

International Nuclear Information System (INIS)

HT-29 human colon tumor cells growing as spheroids have been evaluated as a model system for measuring the response of human colon tumor cell to antineoplastic agents. HT-29 cells have been capacity to form spheroids up to 1 mm or more in diameter when grown in spinner culture. The multicellular HT-29 spheroids develop hypoxic centers reflecting the cellular conditions found in human cancer treatment, i.e., nutritionally deficient hypoxic cells that are felt to be a significant source of both radiation and chemotherapy clinical treatment failures. Spheroids of increasing size were radiated and then dispersed into single cells for colony survival assay. Compared with irradiated single cell suspensions, the spheroid cells demonstrated a significant increase in radioresistance. Growing spheroids developed a complex radiation survival curve which was variable with respect to size of the spheroid. The drug ...

72

Development of radiological emergency preparedness technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological ...

2000-04-01

73

Radiation protection in connection with the decommissioning of nuclear plants  

Energy Technology Data Exchange (ETDEWEB)

This document presents the SSI preliminary views and position concerning the decommissioning of nuclear plants. To prevent the exposure of the decommissioning personnel and the general public to unacceptable levels of radiation and to protect the environment and future generations, it is SSI`s task to formulate and issue the necessary terms and regulations with which the reactor licensees must comply during the decommissioning work. The views and principles presented here are the basis of SSI`s continued work on guidelines and regulations for the decommissioning of nuclear plants.

1997-04-01

74

Concepts in radiation protection  

International Nuclear Information System (INIS)

This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the ...

1996-01-01

75

The medical exposures to ionizing radiations, it is a world priority in radiation protection  

International Nuclear Information System (INIS)

The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)

76

Study of the physical and mechanical changes in packaging materials used in radiation processing - measuring methods of physical and mechanical properties  

International Nuclear Information System (INIS)

The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline ...

77

Role of additives in wood plastic composite of water soluble monomer  

International Nuclear Information System (INIS)

Wood plastic composites are prepared under radiation of "6"0Co gamma source with simul, a low grade wood of Bangladesh using a water soluble monomer acrylamide (AM) mixed with a swelling solvent methanol, water or methanol/water (1:1) at different compositions in the presence of a number of additives and co-additives such as NVP (N-vinylpyrrolidone), TPGDA (tripropylene glycol diacrylate), TMPTA (trimethylol propane triacrylate), sulfuric acid, urea and copper sulfate. Polymer loading (PL) and tensile strength (TS) of the composites are measured. The role of these additives on the composites is also discussed. It is observed that nitrogen-atom containing-materials like urea, NVP and AM produce composites with the highest mechanical strength, and incorporation of copper into this system provides additional property of protection and preservation of the composites against attacks by insects and microbes. (author).

1994-01-01

78

Radioexposure of children in cranial examinations with new-generation CT equipment  

Energy Technology Data Exchange (ETDEWEB)

Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.

1983-04-01

79

Lessons learned from accidents in industrial radiography  

International Nuclear Information System (INIS)

Industrial radiography accounts for approximately half of all the reported accidents for the nuclear related industry, in both developed and developing countries. This Safety Report is the result of a review made of a large selection of accidents in industrial radiography reported by regulatory authorities, professional associations and scientific journals. A small, representative selection of 43 accident descriptions has been used to illustrate the primary causes of radiography accidents, and a set of measures provided to prevent the recurrence of such accidents or to mitigate the consequences of those that do occur. These accident descriptions were categorized by primary causes as follows: inadequate regulatory control; failure to follow operational procedures; inadequate training; inadequate maintenance; human error; equipment malfunction or defect; design flaws; and wilful violation. The information in this Safety report is intended for use by those regulatory ...

80

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

81

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

82

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The deliveration by the Nuclear Safety Commission was commenced on the alteration in reactor installation, as it had been inquired by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc. (J.P.N.).

1980-01-01

83

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The deliberation by the Nuclear Safety Commission was initiated on the alteration in reactor installation, as was required by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc.

1980-10-01

84

Prediction of monitoring data for 239Pu accidentally injected via wound site based on the proposed NCRP wound model.  

Science.gov (United States)

In response to the consultation from the National Council on Radiation Protection and Measurements (NCRP) to the International Commission on Radiological Protection (ICRP) committee 2, retention and excretion of 239Pu deposited at wound site were calculated by coupling together the proposed NCRP wound model and the current ICRP systemic model of Pu. The physicochemical forms considered were the soluble form categorized into 'Strong Retention', and the colloidal, particulate and fragmentary forms. The results are summarized as follows. If in soluble form, immediate medical intervention is needed to prevent uptake of radionuclides to body tissues, and prompt wound monitoring is essential for an accurate estimation of the initially deposited radioactivity. If in particulate form, a multi-component exponential equation leads to an overestimation of the absorption rate to blood because of significant lymph ...

2007-06-07

85

Maintaining Quality Performance in a Rapidly Changing Workplace - NASA  

Science.gov (United States)

360 degree Surveys. Measuring. Measuring successes successes ... Self- Assessment. Safeguards. Equipment. Reactor. Protection. Systems. Containment ...

86

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

1992-11-01

87

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

88

Individual Radiation Protection Monitoring in the Marshall Islands: Rongelap Atoll (2002-2004)  

Energy Technology Data Exchange (ETDEWEB)

The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities ...

2006-01-17

89

Punica granatum peel extract protects against ionizing radiation-induced enteritis and leukocyte apoptosis in rats  

International Nuclear Information System (INIS)

Radiation-induced enteritis is a well-recognized sequel of therapeutic irradiation. Therefore we examined the radioprotective properties of Punica granatum peel extract (PPE) on the oxidative damage in the ileum. Rats were exposed to a single whole-body X-ray irradiation of 800 cGy. Irradiated rats were pretreated orally with saline or PPE (50 mg/kg/day) for 10 days before irradiation and the following 10 days, while control rats received saline or PPE but no irradiation. Then plasma and ileum samples were obtained. Irradiation caused a decrease in glutathione and total antioxidant capacity, which was accompanied by increases in malondialdehyde levels, myeloperoxidase activity, collagen content of the tissue with a concomitant increase 8-hydroxy-2'-deoxyguanosine (an index of oxidative DNA damage). Similarly, pro-inflammatory cytokines (TNF-?, IL-1? and IL-6) and lactate dehydrogenase were elevated in irradiated groups as compared to control. PPE treatment reversed ...

2009-07-01

90

Investigations of excretion rates of the radionuclides {sup 230}Th, {sup 226}Ra, {sup 210}Pb and {sup 210}Po of persons of the general population and of workers in selected regions in Germany  

Energy Technology Data Exchange (ETDEWEB)

According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the ...

2006-07-01

91

Radiofrequency electromagnetic fields in the Cookridge area of Leeds  

Energy Technology Data Exchange (ETDEWEB)

On the 8 and 9 May 2002 representatives of the National Radiological Protection Board (NRPB) performed a radiofrequency electromagnetic field survey in the Cookridge area of Leeds in order to assess exposure to radio signals from transmitters mounted on a water tower/a lattice tower and a radio station tower. Guidelines on limiting exposure to radio signals have been published by NRPB and the International Commission on Non-Ionizing Radiation Protection (ICNIRP). These guidelines are designed to prevent established adverse effects on human health. During this survey, the total exposures due to all radio signals from 30 MHz to 18000 MHz (18 GHz) were measured. This frequency range was chosen as it includes mobile phone base station transmissions, which are at around 900 and 1800 MHz and super high frequency (SHF) transmissions from most of the large microwave dish antennas mounted on the towers. In ...

2002-07-01

92

Radon-mitigation in buildings  

International Nuclear Information System (INIS)

From the indoor radon problem arises a great challenge for the radiation protection of the population. The soil can be considered as the only source for high radon concentrations in buildings. The contribution of common building materials to high indoor concentrations with a range of 30 Bq/m"3 is negligible low. Therefore building materials for radon mitigation should be judged by their tightness against diffusive radon and not by their radon exhalation rate. Also isolation materials for mitigation should be radon tight. The radon diffusion coefficient describes the physical processes in relatively homogeneous samples. The diffusion coefficient D and the diffusion length R are very exactly determined by a self engineered measuring method. The range of D reaches from D = (0.0005 to 2.35) . 10"-"6 m"2/s for building materials and from D = (0.07 to < 10"-"6) . 10"-"6 m"2/s for isolation materials. Applicable mitigation ...

93

VGB guidelines on the consideration of noise emission in ordering power plant equipment  

International Nuclear Information System (INIS)

The present guidelines supplement the 'VGB guidelines for the reduction of noise in thermal power plants' with indications for the ordering and quality assurance of the individual noise-producing machines and equipment of power plant operation. These guides are to simplify the commissioning and delivering for the orderer and deliverer. In addition, these guidelines are to lead to a successful cooperation of all parties in the reduction of the sound radiation. A precondition for this is an explanation of the sound technical demands which must be made on the single machines or mechanical equipment in power plant systems. A protection of the neighbourhood as well as operational personnel against noise according to the state of technology is to be achieved by a clear form of ordering and quality assurance. The ordering and assurance procedure for all aggregates in the region of the grounds of a power plant up to the high-voltage side of the machine ...

94

New concepts in risk assessment for patients with radiological treatment  

International Nuclear Information System (INIS)

In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.

1986-01-01

95

Health risks arising from ionizing radiation and chemical pollutants  

International Nuclear Information System (INIS)

In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the basis of the rules and ...

1979-10-03

96

Sandia National Laboratories/California site environmental report for 1997  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of SNL/California`s Environmental Monitoring ...

1998-06-01

97

Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects  

Energy Technology Data Exchange (ETDEWEB)

Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...

1996-12-31

98

Practice and experience of radiation protection and optimization (ALARA) management system in Daya Bay NPP during the past 10 years  

International Nuclear Information System (INIS)

With the practice of 10 years safe operation, Daya Bay Nuclear Power Station has established and continuously improved the management system for radiation protection and optimization (ALARA) which contains 3 basic requirements: all workers are trained, all employees are engaged in totally, and work management is implemented for the whole process. At the same time, strong efforts have been made to build the 'infrastructure' as a platform for its effective operation. This article introduces the contents and characteristics of the system and basic experiences of its effective implementation. In order to implement the management system effectively, it is necessary for NPPs to strengthen the responsibility system for radiation protection and the leading role of the radiation protection personnel, especially the role of technical support and supervision during the ...

2004-05-01

99

Biological radiation effects  

International Nuclear Information System (INIS)

The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable ...

1976-01-01

100

Technical note relative to the incident of the 31. october 2001 and to the fallout of ruthenium incidents occurring at Cogema-La Hague in 2001; Note technique relative a l'incident du 31 octobre 2001 et aux retombees des incidents ruthenium survenus a Cogema-La Hague en 2001  

Energy Technology Data Exchange (ETDEWEB)

It is the Office of protection against the ionizing radiations (O.P.R.I.) who alerted the A.C.R.O. that a new ruthenium incident had arisen to the factory Cogema - La Hague on October 31., 2001. The A.C.R.O. immediately made a campaign of analyses the results of which are presented in this note. The previous similar incident dates May 18., 2001. A loss of depression in the workshop R7 of the factory UP2-800 specialized in the vitrification had brought an unchecked release, by one of the smokestacks, composed essentially of radioactive ruthenium and rhodium; the evacuated activity was estimated by the operator at approximately 11 MBq. The measures in environment made by the A.C.R.O. had led the association to question the Authority of Nuclear Safety about the total quantity of release announced by the operator. Having presented the results of the measures of radioactivity in the environment made ...

2002-07-01

101

Radiological follow-up of the environment of the G.I.P. CYCERON of Caen - year 2005 - 2006 - assessment 2007; Suivi radiologique de l'environnement des installations du GIP CYCERON de Caen - annee 2005 - 2006 - bilan 2007  

Energy Technology Data Exchange (ETDEWEB)

The present study answers at the request of the Inspection of the classified installations to see the operator of the G.I.P. Cyceron setting up a plan of environmental radiological surveillance around its installations and including, at a minimal level, the following data: Measures of radioactivity on representative biological indicators and measures of dose rate in the environment close to installations in functioning. Further to the radiological assessment of the terrestrial environment of the G.I.P. Cyceron installations realized at the end of 2003, within the framework of a project of the installations extension, the A.C.R.O. was again required for the implementation of this radiological surveillance for year 2005. The first purpose is to supply elements of appreciation about the impact of these installations on environment and persons. This evaluation participates in radiation protection and allows ...

2007-07-01

102

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues  

International Nuclear Information System (INIS)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far.

2003-03-01

103

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, ...

2006-07-01

104

VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...  

Science.gov (United States)

Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...

105

The importance and unique aspects of radiation protection in medicine  

British Library Electronic Table of Contents (United Kingdom)

Radiation protection in medicine has unique aspects and is an essential element of medical practice. Medical uses of radiation occur throughout the world, from large cities to rural clinics. It has been estimated that the number of medical procedures using radiation grew from about 1.7 billion in 1980 to almost 4 billion in 2007. In spite of these large numbers, there are many parts of the world without adequate equipment, where the ability to perform additional medical procedures would likely result in a net benefit. Medicine accounts for more than 99.9% of the per caput effective dose from man-made sources. The goal in medical exposure is not to give the lowest dose, but to provide the correct dose to enable the practitioner to make the diagnosis or cure a tumour. Too little or too much ...

2010-01-01

106

Project W-314 Polyurea Special Protective Coating (SPC) Test Plan Chemical Compatibility and Physical Characteristics Testing  

Energy Technology Data Exchange (ETDEWEB)

This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.

2001-01-15

107

Radiation control aspects of the civil construction for a high power free electron laser (FEL) facility  

International Nuclear Information System (INIS)

The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.

1996-11-06

108

Tritium bioassay and dosimetry at a CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.

1996-07-01

109

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is ...

110

Radon in soil gas survey in Curitiba (Brazil)  

International Nuclear Information System (INIS)

This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the ...

2002-10-08

111

Immunological correlates for protection against intranasal challenge of Bacillus anthracis spores conferred by a protective antigen-based vaccine in rabbits.  

Science.gov (United States)

Correlates between immunological parameters and protection against Bacillus anthracis infection in animals vaccinated with protective antigen (PA)-based vaccines could provide surrogate markers to evaluate the putative protective efficiency of immunization in humans. In previous studies we demonstrated that neutralizing antibody levels serve as correlates for protection in guinea pigs (S. Reuveny et al., Infect. Immun. 69:2888-2893, 2001; H. Marcus et al., Infect. Immun. 72:3471-3477, 2004). In this study we evaluated similar correlates for protection by active and passive immunization of New Zealand White rabbits. Full immunization and partial immunization were achieved by single and multiple injections of standard and diluted doses of a PA-based vaccine. Passive immunization was carried out by injection of immune sera from rabbits vaccinated with PA-based vaccine prior to ...

2006-01-01

112

Principles of protection: a formal approach for evaluating dose distributions  

International Nuclear Information System (INIS)

One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.

2006-03-01

113

Potential Protection of Green Tea Polyphenols Against 1800?MHz Electromagnetic Radiation-Induced Injury on Rat Cortical Neurons  

British Library Electronic Table of Contents (United Kingdom)

Radiofrequency electromagnetic fields (EMF) are harmful to public health, but the certain anti-irradiation mechanism is not clear yet. The present study was performed to investigate the possible protective effects of green tea polyphenols against electromagnetic radiation-induced injury in the cultured rat cortical neurons. In this study, green tea polyphenols were used in the cultured cortical neurons exposed to 1800?MHz EMFs by the mobile phone. We found that the mobile phone irradiation for 24?h induced marked neuronal cell death in the MTT (3-(4,5-dimethylthiazole-2-yl)-2,5-diphenyl-tetrazolium bromide) and TUNEL (TdT mediated biotin-dUTP nicked-end labeling) assay, and protective effects of green tea polyphenols on the injured cortical neurons were demonstrated by testing the content ...

2011-01-01

114

Using ICCD as a fast optical switch to measure harmonic super-radiation from an optical klystron in a storage ring  

International Nuclear Information System (INIS)

An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate

2001-07-01

115

Regulatory quality assurance requirements for the operation of nuclear R and D facilities in Korea  

International Nuclear Information System (INIS)

Full text: Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation. including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently. nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. All provisions on nuclear safety regulation and radiation protection are entrusted to the Atomic Energy Act(AEA). The Act is enacted as the main law concerning the safety regulation of nuclear ...

2006-10-15

116

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and ...

2008-05-01

117

Laser eye protection. Interim report, July 1989-January 1990  

Energy Technology Data Exchange (ETDEWEB)

Laser applications have proliferated in recent years and, as to be expected, their presence is no longer confined to the laboratory or places where access to their radiation can be easily controlled. One obvious application where this is so is in military operations where various devices such as laser range finders, target designators, and secure communications equipment elevate the risk of exposure, specifically eye exposure, to unacceptable levels. Although the need for eye protection in the laboratory and other controlled areas has been appreciated since the invention of the laser, the use of lasers in circumstances where safety or the risk of temporary loss of vision, which can not always be ensured by administrative procedures, has made adequate eye protection essential. It is the critical nature of many military operations that has driven the search for eye protection against both nuclear and ...

1990-01-01

118

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

119

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

120

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting; Die Messung des Dosisflaechenproduktes in der diagnostischen Radiologie als Methode zur Ermittlung der Strahlenexposition. (Ergebnisse, Erfahrungen, Verbesserungsvorschlaege und Empfehlungen zum Strahlenschutz). Bericht ueber ein Expertentreffen  

Energy Technology Data Exchange (ETDEWEB)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including ...

1995-12-31

121

35 years of Thermoluminescence Dosimetry (TLD) in personnel and environmental monitoring in India - a tribute to Dr. K G Vohra  

International Nuclear Information System (INIS)

Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully ...

122

Experience with protection and restoration measures on reinforced concrete structures; Erfahrungen mit Schutz- und Instandsetzungsmassnahmen an Stahlbeton-Konstruktionen  

Energy Technology Data Exchange (ETDEWEB)

Often measures of protection and restoration of reinforced concrete structures are not taken until damage occurs which affects power plant operation. These failures can be avoided by predictive civil engineering maintenance and repair. The consequent application and implementation of a life-time management system for power plant buildings is being suggested. (orig.)

2008-07-01

123

Synchrotron resource of the Howard Hughes Medical Institute  

Energy Technology Data Exchange (ETDEWEB)

The Synchrotron Resource of the Howard Hughes Medical Institute will be dedicated to structural analyses of biological macromolecules, primarily through crystallography. This facility is under construction at the X4 port of the National Synchrotron Light Source at Brookhaven National Laboratory, and it will comprise three beamlines. The first line to be built has been devised to apply the multiwavelength anomalous diffraction method which provides direct estimates for the phases of reflections. The second line will be devoted to rapid and essentially routine diffraction measurements, mainly through the rotation method. These two experimental stations are contained within refrigerated radiation enclosures that will maintain clean environments, narrowly defined constant temperatures, and protection against biohazard at biosafety level BL-2. At the same time as the second line will be developed, the swath center is planned to ...

1989-07-01

124

Radiological aspects of the usability of red mud as building material additive  

International Nuclear Information System (INIS)

Several researchers have examined and achieved favourable results in connection with the building industry's use of red mud extracted in large quantities from the processing of bauxite. These days more and more precedence is being given to limiting the radiological dose to the population. In this study carried out in Hungary, the use of red mud, bauxite, and clay additives recommended for the production of special cements, were examined from a radiological aspect. "2"2"6Ra and "2"3"2Th activity concentrations measured in Hungarian bauxite, red mud and clay samples were significantly similar with the levels for such raw materials mentioned in international literature. Taking radiation protection aspects into consideration, none of these products can be directly used for building construction. Taking Hungarian and international values into consideration, a small amount of red mud, not exceeding 15% could be used for brick ...

2008-02-11

125

Investigation of natural radionuclides in selected NORM-samples  

International Nuclear Information System (INIS)

A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different ...

2005-09-20

126

Implementation of the NCRP wound model for interpretation of bioassay data for intake of radionuclides through contaminated wounds.  

Science.gov (United States)

Emergency response preparedness for radiological accidents involving wound contamination has become more important, considering the current extending tendency in the nuclear industry related to the nuclear fuel cycle. The US National Council on Radiation Protection and Measurements (NCRP) proposed a biokinetic and dosimetric model for the intake of radionuclides through contaminated wounds in 2007. The present paper describes the implementation of this NCRP wound model for the prediction of systemic behaviour of some important radioactive elements encountered in workplaces related to the nuclear industry. The NCRP wound model was linked to the current ICRP systemic model at each blood compartment and simultaneous differential equations for the content of radioactivity in each compartment and excreta were solved with the Runge-Kutta method. The results of the calculation of wound, whole-body or specific organ retention and ...

2009-05-01

127

Home radon levels and seasonal correction factors for the Isle of Man  

Energy Technology Data Exchange (ETDEWEB)

Ionizing radiation dose levels due to home radon can rise to levels that would be illegal for workers in the nuclear industry. It is well known that radon levels within homes and from home to home, and also from month to month, vary considerably. To define an Isle of Man radon seasonal correction factor, readings were taken in eight homes over a 12 month period. An average island indoor exposure of 48 Bq m{sup -3} (range 4-518 Bq m{sup -3}) was determined from 285 homes selected from a cohort of 1300 families participating in the European Longitudinal Study of Pregnancy and Childhood (ELSPAC) in the Isle of Man. This compares with a UK home average of 20 Bq m{sup -3} and a European Union average (excluding UK) of 68 Bq m{sup -3}. Ten homes of those measured were found to have radon levels above the National Radiological Protection Board 200 Bq m{sup -3} action level. There are 29 377 homes on the Isle of Man, suggesting ...

2000-08-01

128

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % ...

2005-11-23

129

Cytotoxic effects of WR-2721 on mouse testicular cells  

Energy Technology Data Exchange (ETDEWEB)

WR-2721 (S-2-(3-aminopropylamino)ethylphosphorothioic acid) has been demonstrated to be cytotoxic to stem spermatogonia in the mouse. Five and 10 injections of 300 mg/kg killed sufficient numbers of stem cells to reduce sperm production 56 days after treatment by 16 and 43%, respectively. Single injections of 300 or 400 mg/kg of WR-2721 given 15 min after irradiation produced negligible toxicity to stem cells as measured by counts of repopulated tubules; 600 mg/kg reduced stem cell survival by 47%. Four daily injections of 300 mg/kg given 4, 3, 2, and 1 days prior to irradiation reduced stem cell survival by about 60%. The cytotoxic effects of WR-2721 on testicular stem cells at least partially explains the reduced protection factors observed in the testis with low doses of radiation and during fractionated treatments involving multiple injections of drug.

1984-09-01

130

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the present work is the evaluation of the gamma ...

2007-11-05

132

The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)  

International Nuclear Information System (INIS)

As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.

133

Radiation safety in industrial applications  

International Nuclear Information System (INIS)

Oil and gas industry is the largest user of radioactive materials in Nigeria. They make use of radiation generators, sealed and unsealed radioactive sources.Some of these are potentially dangerous to human health and environment if not properly controlled. here is also the need to maintain control over occupational exposures to radiation, as well as to protect the public and the environment through proper management of wastes that may be radiologically hazardous. To minimize these, effective regulatory infrastructure is being put in place.For a smooth take-off of the nuclear power program, the National Nuclear Regulatory Authority and other stake holders in the nuclear industry need to start to put together licensing procedure for these.

2008-03-17

134

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

135

UV inactivation: Combined effects of UV radiation and xenobiotics in two strains of Saccharomyces  

International Nuclear Information System (INIS)

The effects of eight chemicals on the inactivation rate of ultraviolet radiation on the colony building capabilities of two strains of Saccharomyces cervisae - a wild type strain and a mutant deficient in excision repair - were studied. The insecticide methoxychlor, the herbicide 2,4-dichlorophenoxyacetic acid, the fungicide pentachlorophenol and its metabolite tetrachlorohydroquinone, as well as the chemicals acrylonitrile and 2,3-dichloro-1-propene have no significant impact on the effects of UV radiation in Saccharomyces cerevisae. Depending on the concentration, trichloroethylene increases the sensitivity to UV radiation. The herbicide paraquat provides efficient protection against UV radiation at concentrations where a toxic effect cannot be observed even without UV. The results were rather similar for both strains. (orig.).

136

Radiation protection and the role of TSOs in Kenya  

International Nuclear Information System (INIS)

Since the late '60s and through the early '90s Kenya has always recognized and appreciated the need for support from Technical and Scientific Support Organizations (TSOs) for activities geared towards enhancing nuclear and radiation safety. The TSOs have since then gained increasing importance for provision of technical and scientific basis for policy formulation, implementation and legislation with regard to radiation safety. National and specific operator programmes on safety and security of radiation source and radioactive waste recognize and encourage the active participation of TSOs. Due to the role they play, technical competence, transparency and the observance of ethical practices have become essential both for the regulator and the regulated. In this respect, interaction and cooperation between stake holders (regulatory authorities, users of radiation, generators of radioactive waste, ...

2007-08-01

137

Non-destructive measurement of corrosion effects on high temperature coatings  

Energy Technology Data Exchange (ETDEWEB)

Non-destructive methods for measuring the remaining anticorrosive or antioxidative ability of coatings are investigated. For anticorrosive chromium coatings the increasing ferromagnetism caused by loss of chromium is measured by a permeability probe. Measured values on blades after operation are correlated with the progress of corrosion as determined by metallographic methods. For antioxidative aluminum coatings the diminishing layer thickness is taken as indication for the exhaustion of their protection ability. The layer thickness is measured eddy current probes, especially developed for this application.

1990-01-01

138

Protection provided by criminal law against hazards of nuclear energy and the harmful effects of ionizing radiation. Also a survey of the history of definition of offences against the atomic energy law and radiation protection law in the Federal Republic of Germany. Der strafrechtliche Schutz vor den Gefahren der Kernenergie und den schaedlichen Wirkungen ionisierender Strahlen. Zugleich eine Darstellung der historischen Entwicklung der Kernenergie- und Strahlendelikte in der Bundesrepublik Deutschland  

Energy Technology Data Exchange (ETDEWEB)

The subjects, principles and purpose of the atomic energy law and the radiation protection law are set out, and criminal offences under atomic energy law are outlined explaining the legal terminology applied. The peaceful uses of nuclear energy and radioactive materials are briefly discussed, primarily looking at the hazards involved and the protective role of criminal law principles that have been developed in connection with the atomic energy law and its application in practice. The draft version of the 16th criminal law amendment act - Act to combat environmental delinquency - is discussed, which aims at adoption of all criminal offences under atomic energy law by the Criminal Code. The book furthermore presents considerations about basic features of delinquency under atomic energy and radiation protection law, revealing elements and facts of offences defined, and particular ...

1989-01-01

139

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...

2011-01-01

140

Comparison and analysis of results of ? radiation level investigation around Daya Bay  

International Nuclear Information System (INIS)

Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)

2003-08-01

141

Results of a cross-sectional study on the association of electromagnetic fields emitted from mobile phone base stations and health complaints; Ergebnisse einer Querschnittsstudie zum Zusammenhang von elektromagnetischen Feldern von Mobilfunksendeanlagen und unspezifischen gesundheitlichen Beschwerden  

Energy Technology Data Exchange (ETDEWEB)

Background: Despite the fact that adverse health effects are not confirmed for exposure to radiofrequency electromagnetic field (RFEMF) levels below the limit values, as defined in the guidelines of the International Commission on Non-Ionizing Radiation Protection, many persons are worried about possible adverse health effects caused by the RF-EMF emitted from mobile phone base stations, or they attribute their unspecific health complaints like headache or sleep disturbances to these fields. Method: In the framework of a cross-sectional study a questionnaire was sent to 4150 persons living in predominantly urban areas. Participants were asked whether base stations affected their health. Health complaints were measured with standardized health questionnaires for sleep disturbances, headache, health complaints and mental and physical health. 3,526 persons responded (85%) to the questionnaire and 1,808 (51%) agreed to ...

2010-07-01

142

A.C.R.O. activity report 1999; A.C.R.O. rapport d'activite scientifique 1999  

Energy Technology Data Exchange (ETDEWEB)

The work of this association is cut according to 6 axes. Three publications: radiological quality of marine and continental waters of the Normandy coast (synthesis 1997 and 1998); preliminary study of the iodine 129 distribution in the environment of the reprocessing plant of La Hague with terrestrial moss (Homalotecium sericeum); radiological surveillance of the aquatic environment of the nuclear facilities on the area of La Hague (1997 and 1998). The second axis concerns the radiation protection with a campaign of radon measures in a school of the Vire rural district (june 1999). The third part is devoted to the radioecology with the surveillance of radioactivity in the aquatic continental environment of nuclear facilities and the radioecological surveillance (1999) of the building site of Cogema la Hague in the area of tidal range of the Moulinets cove. The fourth part concerns the radioactive waste and environment, with ...

1999-07-01

143

Interaction of free fatty acids with the erythrocyte membrane as affected by hyperthermia and ionizing radiation  

Energy Technology Data Exchange (ETDEWEB)

The interference of hyperthermia and ionizing radiation, respectively, with the effects of capric (10:0), lauric (12:0), myristic (14:0), oleic (cis-18:1) and elaidic (trans-18:1) acids on the osmotic resistance of human erythrocytes was investigated. The results are summarized as follows: (A) not only at 37 degrees, but also at 42 and 47{degrees}C lauric acid (12:0) represents the minimum chain length for the biphasic behaviour of protecting against hypotonic hemolysis at a certain lower concentration range and hemolysis promotion at subsequent higher concentrations; (B) with increasing temperatures the protecting as well as the hemolytic effects occur at lower concentrations of the fatty acids; (C) the increase of temperature promotes the extent of hemolysis and reduces the extent of protection against hypotonic hemolysis; (D) Gamma-irradiation of erythrocytes selectively affects the concentration of ...

1990-04-01

144

Properties of composite materials on the base of radiation-hardening binders and metal powders  

International Nuclear Information System (INIS)

Compositions (oligomers with suitable properties and Al, Fe, Cu, Ta, W powders) were hardured by the flux of accelerated electrons at 10 mA beam current and 1.5 MeV energy. Dielectric and mechanical properties of metal-filled polymeric compositions as well as their radioply sicl properties in SHF-range are studied. It is shown that the produced compositions belong tot he absorbing protective materials in which the protection effect is mainly achieved through the absorption losses. 6 refs.; 3 tabs.

145

Medicinal protection with Chinese herb-compound against radiation damage  

Energy Technology Data Exchange (ETDEWEB)

Experiments were carried out on mice and the subjects irradiated for cancer therapy to evaluate the protective efficacy of a Chinese medicinal herb-compound (CMHC). The lethality and the degree of leucopenia caused by radiation in mice medicated with CMHC were significantly less in comparison with control mice (p less than 0.01 and p less than 0.001, respectively). CMHC significantly improved the WBC and the thrombocytes in irradiated workers (p less than 0.01 and p less than 0.001, respectively). The WBC count of 40 patients under radiotherapy while treated with CMHC recovered from 3450 +/- 77/c.mm to 5425 +/- 264/c.mm (p less than 0.001); whereas, in the control group, without any medication, the WBC count dropped significantly (p less than 0.001). Our results revealed the applicabilities of CMHC in protection against radiation damage in spaceflight and in other fields.

1990-08-01

146

Limiting values of radionuclide intake and air concentration and dose conversion factors for inhalation, submersion, and ingestion: Federal guidance report No. 11  

Energy Technology Data Exchange (ETDEWEB)

Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived ...

1988-09-01

147

Insertion Loss of Personal Protective Clothing  

Energy Technology Data Exchange (ETDEWEB)

'The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic ...

1999-05-13

148

Compare analysis of efficiency of using of digital and analog regimes of registration of radiation in radiometric systems of radiation thickness measuring  

International Nuclear Information System (INIS)

A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed

149

Testing and design of radon resisting membranes based on the experience from the Czech Republic  

International Nuclear Information System (INIS)

Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10"-"1"5 m"2/s to 10"-"8 m"2/s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is ...

150

Structure analysis of cation selective Cr-goethite as protective rust of weathering steel  

International Nuclear Information System (INIS)

We have performed extended X-ray absorption fine structure (EXAFS) analysis for artificial Cr-goethite to elucidate the local structure around Cr in Cr-goethite. The spectra were obtained using synchrotron radiation X-rays at the Photon Factory in Tsukuba. The first shell contributions were isolated by Fourier filtering EXAFS data, and the inverse Fourier transformed single-shell data were analyzed using a curve fitting method. The results show that Cr is coordinated with (7#+-#1)O"2"- ions. The protective characteristics of the Cr-goethite protective rust layer on weathering steel can be interpreted in terms of the O"2"- coordination around Cr"3"+ resulting in the creation of negative fixed charge in the Cr-goethite particles. (author)

2005-02-01

151

Health, Safety, and Environment Division: Annual progress report 1987  

Energy Technology Data Exchange (ETDEWEB)

The primary responsibility of the Health, Safety, and Environment (HSE) Division at the Los Alamos National Laboratory is to provide comprehensive occupational health and safety programs, waste processing, and environment protection. These activities are designed to protect the worker, the public, and the environment. Many disciplines are required to meet the responsibilities, including radiation protection, industrial hygiene, safety, occupational medicine, environmental science, epidemiology, and waste management. New and challenging health and safety problems arise occasionally from the diverse research and development work of the Laboratory. Research programs in HSE Division often stem from these applied needs. These programs continue but are also extended, as needed to study specific problems for the Department of Energy and to help develop better occupational health and safety practices.

1988-04-01

152

A qualitative evaluation of radionuclide concentrations in Hanford Site Wildlife, 1983 through 1992  

Energy Technology Data Exchange (ETDEWEB)

Environmental monitoring has been conducted at the U.S. Department of Energy`s (DOE`s) Hanford Site in southeastern Washington State since 1945. Fish and wildlife have been monitored since 1945, however, a major emphasis on mammals did not occur until the 1970s. This report focuses on the 10-year period from 1983 through 1992. The objectives of this report are to evaluate {sup 90}Sr and {sup 137}Cs concentrations in Site wildlife populations and, when possible, evaluate trends in concentrations over this period of time. No distinct trends in radionuclide concentrations were apparent in most species sampled. Many measurements were at or below the analytical limit of detection. This evaluation found that concentrations of {sup 90}Sr in rabbit and deer bone were elevated in animals collected from areas adjacent to industrialized areas. Similarly, radionuclide concentrations in duck muscle from waterfowl collected at B Pond were elevated with {sup 137}Cs when compared ...

1994-10-01

153

A case of wound intake of plutonium isotopes and 241Am in a human: application and improvement of the NCRP wound model.  

Science.gov (United States)

Plutonium isotopes (239Pu and 238Pu, and 241Am) with a total activity of 269 kBq were accidentally deposited in a puncture wound of the right index finger of a nuclear worker at the Mayak Production Association. Tissues surrounding the wound site contaminated with radionuclides were excised 4.5 h after the injury. Residual contamination within the wound amounted to 0.05% of the initial contamination. The 10-d therapy with CaNa3-diethylene triamine pentaacetate acid (CaNa3-DTPA) was performed in parallel with in vivo measurements of the wound site and daily urine bioassays. The wound intake of radionuclides was consistent with two forms of radioactive materials detected within the wound site, i.e., soluble compounds and a large fragment, which was completely removed by excision. On day 9 after the injury, the clearance rate from the wound site was 1.8 times higher than the rate predicted by the National Council on Radiation ...

2010-10-01

154

Equipment hardening and hardness assurance  

International Nuclear Information System (INIS)

The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to ...

155

Enhanced coherent undulator radiation from bunched electron beams  

International Nuclear Information System (INIS)

When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch ...

1995-09-28

156

Solar energy apparatus with apertured shield  

Energy Technology Data Exchange (ETDEWEB)

This paper describes in an apparatus for absorbing a beam of concentrated solar energy and which includes a cavity receiver with an inlet for transmission thereinto of solar radiation, a protective apertured shield means about the inlet. It comprises: rigid support means fixed to the periphery of the inlet and projecting radially inwardly therefrom to define a generally central aperture area through which the solar radiation can pass into the cavity receiver; and non-structural blanket means spread over the rigid support means between the periphery of the inlet and the aperture area, the material having a high temperature capability and providing for infra-red radiation insulation, while remaining relatively cool when subjected to solar radiation.

1989-07-25

157

Radiation Protection Aspects of the Linac Coherent Light Source Front End  

Energy Technology Data Exchange (ETDEWEB)

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

2010-08-26

158

Regulation of naturally occurring radioactive materials in Australia  

British Library Electronic Table of Contents (United Kingdom)

In order to promote uniformity between jurisdictions, the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) has developed the National Directory for Radiation Protection, which is a regulatory framework that all Australian governments have agreed to adopt. There is a large and diverse range of industries involved in mining or mineral processing, and the production of fossil fuels in Australia. Enhanced levels of naturally occurring radionuclides can be associated with mineral extraction and processing, other industries (e.g. metal recycling) and some products (e.g. plasterboard). ARPANSA, in conjunction with industry and State regulators, has undertaken a review and assessment of naturally occurring radioactive material (NORM) management in Australian industries. This rev...

2011-01-01

159

In vitro H2AX phosphorylation and micronuclei induction in human fibroblasts across the Bragg curve of a 577MeV/nucleon Fe incident beam  

Energy Technology Data Exchange (ETDEWEB)

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts ...

2006-10-15

160

Modulating factors in the expression of radiation-induced oncogenic transformation  

Energy Technology Data Exchange (ETDEWEB)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-08-01

161

Modulating factors in the expression of radiation-induced oncogenic transformation  

International Nuclear Information System (INIS)

Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...

1990-01-01

162

Rubidium uptake by mouse pancreatic islets exposed to 6-hydroxydopamine, ninhydrin, or other generators of hydroxyl radicals  

International Nuclear Information System (INIS)

The purpose was to study the toxicity of drugs known to generate free radicals on isolated pancreatic islets. The accumulattion of "8"6Rb"+ by mouse pancreatic islets was measured in vitro. Exposing the islets to 6-hydroxydopamine, minhydrin, or phenazine methosulphate + NADH inhibited the Rb"+ uptake, whereas paraquat or acetylphenylhydrazine had no effect. This effect of 6-hydroxydopamine was prevented by either of the hydroxyl radical scavengers, sodium benzoate and mannitol, but not by the non-scavenger,urea; ninhydrin was partially protected against by mannitol but not by benzoate. Protection against 6-hydroxydopamine was also afforded by D-glucose but not by L-glucose or 3-O-methyl-D-glucose; none of the sugars protected against ninhydrin. In damaging islet beta-cells and in being protected against by D-glucose, 6-hydroxydopamine closely resembles the diabetogenic drug, ...

163

Packaging materials for use in radiation processing of foods  

International Nuclear Information System (INIS)

In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, ...

164

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

165

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

166

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

167

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

168

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

169

Inhibited spontaneous emission by a Rydberg atom  

Science.gov (United States)

Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.

1985-11-11

170

EPR dosimetry in chemically treated fingernails  

UK PubMed Central (United Kingdom)

By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available

2007-08-01

171

The sanitary consequences of chronicle internal contaminations by radionuclides. Advice on the C.E.R.I. report 'study of sanitary effects of exposure to low doses of ionizing radiation to radiation protection purposes ' and I.R.S.N. recommendations; Les consequences sanitaires des contaminations internes chroniques par des radionucleides. Avis sur le rapport CERI 'Etudes des effets sanitaires de l'exposition aux faibles doses de radiations ionisantes a des fins de radioprotection' et recommandations de l'IRSN  

Energy Technology Data Exchange (ETDEWEB)

The report published in 2003 by the European committee on the risk of irradiation (C.E.R.I.) criticizes a part of the ICRP recommendations relative to the internal contaminations.Consequently, I.R.S.N. wishes to supply its own analysis. The present report points the questions linked to the internal contamination and to the difficulties inherent to the risk incurred after chronic exposure.Consequently it does not treat all the problems of the workers and populations radiation protection. (N.C.)

2005-07-01

172

Proceedings of a specialist meeting on regulatory approaches for the control of environmental residues containing naturally occurring radioactive material. Working material  

International Nuclear Information System (INIS)

Naturally occurring radionuclides are present in most material. The most common naturally occurring radionuclides in material are those of the uranium and thorium series and potassium-40. This material is commonly referred to as Naturally Occurring Radioactive Material (NORM). In some material the levels of naturally occurring radionuclides are significantly higher, to the extent that regulatory control may be required for radiation protection purposes. Regulation of NORM presents a range of new challenges for both regulators and operators. Unlike more traditional industries dealing with radionuclides, NORM industries have generally not had any radiological oversight and, for example, are not equipped for radiological monitoring. Some consumer goods containing NORM, which have not traditionally been considered as a radiological problem (such as some fertilizers), may require regulation and this may have social and economic consequences. The ...

2002-09-23

174

Electrochemical Processes : Lecture Notes for a course in Applied Inorganic Chemistry  

DEFF Research Database (Denmark)

The notes describe in detail primary and secondary galvanic cells, fuel cells, electrochemical synthesis and electroplating processes, corrosion: measurments, inhibitors, cathodic and anodic protection, details of metal dissolution reactions, Pourbaix diagrams and purification of waste water from galvanic industries.

1997-01-01

175

Economic Impact Analysis of Proposed Effluent Limitations Guidelines and Standards for the Centralized Waste Treatment Industry.  

Science.gov (United States)

This report estimates the economic and financial effects of compliance with the proposed effluent limitations guidelines and standards for the Centralized Waste Treatment (CWT) industry. The Environmental Protection Agency (EPA) has measured these impacts...

1995-01-01

176

Characterizing and estimating rice brown spot disease severity using stepwise regression, principal component regression and partial least-square regression*  

UK PubMed Central (United Kingdom)

Detecting plant health conditions plays a key role in farm pest management and crop protection. In this study, measurement of hyperspectral leaf reflectance in rice crop (Oryzasativa...Full Text Available

2007-10-01

177

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

178

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

179

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

180

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

181

Behaviour Features of the Radiative Losses of the Torsatron U-3M Plasma  

International Nuclear Information System (INIS)

The total bolometrically measured plasma radiation losses on the RF heating power were found. The results of measurements demonstrate a nonmonotonic dependence of radiation losses on RF power. Namely, at low RF power levels (80...170 kW) the total radiation losses raised with increasing the RF power. However, the total radiation losses decreased sharply when RF power exceeded 200 kW (down to ?20 kW at 240 kW of RF power). Simultaneously, the intensity of impurity lines fell down significantly, whereas the average electron temperature (found from ECE measurement) increased. The authors consider that screening properties of periphery plasma give reasons for above experimental facts.

2006-01-01

182

On the space-time scales of the surface solar radiation field  

Energy Technology Data Exchange (ETDEWEB)

The characteristic space-time scales of surface solar radiation fields measured by the 111-instrument ME-SONET in Oklahoma are estimated after removal of the diurnal cycle. These estimates of {open_quotes}within-day{close_quotes} are used to deduce the representativeness of surface solar radiation measurements measurement site as a function of time-averaging interval. Nomograms of the relation between point measurements and area averages are given for different space-time-averaging intervals. Examples from the nomograms show, for instance, that under conditions of low mean radiation (cloudy days), the central site point measurements are representative of a spatial area the size of a T42 GCM grid box (280 km X 280 km) if one uses hourly averages and is willing to accept a correlation of 0.45 between area average and point ...

1998-01-01

183

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically ...

2007-11-15

184

Annual meeting on nuclear technology '94. Technical session: Radioactivity measurement networks in Europe  

International Nuclear Information System (INIS)

The Chernobyl reactor accident has pronupted all European countries to rehabilitate their existing measurement and monitoring systems and to design and erect new ones. These systems are meant to ensure a rapid overview on the situation in case of an accident to adopt suitable actions for protection or prevention. 6 papers report on the state of such measurement systems in Europe, inparticular those in France (TELERAY), in Germany (IMIS) and in Switzerland (RADAIR). The IMIS-system is discussed for its extension to Eastern Germany. (HP).

185

Final report of the specific research. Investigations on the analysis of bio-protective factors against radiation. 1998-2000 FY (Research Group of NIRS)  

Energy Technology Data Exchange (ETDEWEB)

This report concerns investigations in the title conducted by 8 groups of National Institute of Radiological Sciences (NIRS) during the period of 1998-2000. The groups are for investigation of: Effects of p53 tumor suppressor gene in radiation-induced leukemia, Role of atm-gene in dose rate effect of ionizing radiation, Function of DNA-dependent protein kinase catalytic subunit (DNA-PK{sub cs}), Functional complementation of radiation-sensitive mutant M10 cell line by human XRCC4 cDNA expression, Role of radiation-induced apoptosis in digital defects in embryonic mice, Functional analysis of S-phase specific novel nuclear protein NP95 by gene targeting, Role of chemokine in T cell development and lymphomagenesis, and establishment of production techniques of gene-modified mice using embryonic stem cells for genetic analysis of radiation-sensitive genes. The groups describe summaries ...

2002-03-01

186

Effective per-capita dose as a yardstick for medical radiation exposure of the population - a supplement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the ...

1984-06-01

187

System 80+trademark Standard Design: CESSAR design certification  

International Nuclear Information System (INIS)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80"+trademark Standard Design. This volume 11 discusses Radiation Protection, Conduct of Operations, and the Initial Test Program.

188

Ozone layer  

Energy Technology Data Exchange (ETDEWEB)

Governments around the world will soon make decisions on policies that could determine the fate of the ozone layer-the Earth's shield from harmful ultraviolet radiation. The Vienna Convention for the Protection of the Ozone Layer, signed on March 22, 1985, created a framework for scientific cooperation and information exchange that will form the basis for a protocol for controlling substances thought to threaten the ozone layer. As of mid-1987, 29 countries had signed the Convention, including the major producers and users of chlorofluorocarbons (CFCs), the most important of suspect chemicals.

1987-12-01

189

Microwaves - the hidden danger. Mikrowellen - die verheimlichte Gefahr  

Energy Technology Data Exchange (ETDEWEB)

Today, highly frequent radio waves are regarded as undangerous to man. Diseases seen at radar-technicians during the 2nd World War, however, indicated that microwaves applied in radar systems were hazardous to health. The Russian work medicine has been knowing microwave-caused hazards in industry since the beginning of the thirties. Therefore in some East-European countries there are terms of protection and severe norms of safety for the staying of persons in the radiation sphere of microwaves.

1987-01-01

190

Internal emitter limits for iodine, radium and radon daughters  

Energy Technology Data Exchange (ETDEWEB)

This paper identifies some of the issues which arise in the consideration of the derivation of new limits on exposure to internal emitters. Basic and secondary radiation protection limits are discussed. Terms are defined and applied to the limitation of risk from stochastic effects. Non-stochastic data for specific internal emitters (/sup 131/I and the radium isotopes) are presented. Emphasis is placed on the quantitative aspects of the limit setting problem. 65 references, 2 figures, 12 tables.

1984-08-15

191

Improvements in or relating to refractory oxide protective coatings for fuel can  

International Nuclear Information System (INIS)

An improved coating for Advanced Gas Cooled Nuclear Reactor austenitic stainless steel fuel cans is described which, tests have shown, inhibits the deposition of carbon on the cans in carbon-containing ionising radiation environments. The coating comprises a refractory oxide which has been prepared by a vapour phase condensation method, in combination with a noble metal. (U.K.).

192

Genetic and somatic risks in X-ray diagnosis  

International Nuclear Information System (INIS)

Based on a literature study an actual summary of the risk-utility problems in X-ray diagnosis is outlined due to the Recommendations of the International Commission for Radiation Protection (ICRP publication 26/1977). Papers demonstrating quantitative assessment of the somatic and genetical risk in X-ray examination are preferably cited and evaluated. It is concluded that the somatic and genetical risk is low in diagnostic ratiology. However, it must not be neglected and has always to be compared to the utility of an examination as well as to other risks of the examination. (author).

1982-01-01

193

Doublet III limiter/armor update  

Energy Technology Data Exchange (ETDEWEB)

The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.

1983-12-01

194

Application of the elemental contents in diet, organ or tissues and urine for Chinese adult men in radiation protection  

International Nuclear Information System (INIS)

Objective: To apply the obtained results from 3 stages of research in Chinese radiation protection field. Methods: Based on the identification of physical, chemical and biological qualities for element and its radionuclides under equilibrium condition, main application of these results in Chinese radiation protection field have been discussed by using reported methods in literature. Results: Based on developing elemental reference values of organs or tissues, whole body burdens and their distribution for Chinese Reference Man, discussed in the above 3 articles, current dietary elemental intakes of 42 elements have been updated, and related basis for certain important parameters of bio-kinetic model for use in radiation protection (for example, f_l, T_e and T_b) have been provided. The internal doses from primordial radionuclides and transfer coefficients of ...

2007-08-01

195

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

196

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and ...

2008-05-01

197

Towards Resonant-State THz Laser Based on Strained p-Ge ...  

Science.gov (United States)

... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...

2006-07-01

198

Measured Temperatures of Solid Rocket Motors Dump Stored ...  

Science.gov (United States)

... TARGET SENSOR-MK 80 SERIES BOMBS ... 5-inch-, and 2.75-inch- diameter rocket motors that ... balance when compared to incoming solar radiation ...

1989-07-01

199

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

200

Measuring characteristics on emissivity using infrared thermometer for RCCS  

International Nuclear Information System (INIS)

In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while ...

2004-12-01

201

Radioactive decay data tables  

Energy Technology Data Exchange (ETDEWEB)

The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiation dosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of current interest in nuclear medicine and ...

1981-01-01

202

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

203

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

204

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

205

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...

2007-07-01

206

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...

2007-05-10

207

Radionuclide Air Emissions Report for the Hanford Site Calendar year 1998  

Energy Technology Data Exchange (ETDEWEB)

This report documents radionuclide air emissions from the Hanford Site in I998 and the resulting effective dose equivalent to the maximally exposed individual (MEI) member of the public. The report has been prepared in accordance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (40 CFR SI), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,'' and with the Washington Administrative Code Chapter 246-247, Radiation Protection--Air Emissions. The federal regulations in 40 CFR 61, Subpart H; require the measurement and reporting of radionuclides emitted from Department of Energy facilities and the resulting offsite dose from those emissions. A standard of 10 mrem/yr effective dose equivalent (EDE) is ...

1999-06-15

208

Elk and Deer Study, Material Disposal Area G, Technical Area 54: Source document  

Energy Technology Data Exchange (ETDEWEB)

As nuclear research has become more prevalent, environmental contamination from the disposal of radioactive waste has become a prominent issue. At Los Alamos National Laboratory (LANL) in northern New Mexico, radioactive contamination from disposal operations has raised some very specific concerns. Material Disposal Area G (Area G) is the primary low-level radioactive waste disposal site at LANL and occupies an area adjacent to land belonging to the Native American community of the Pueblo of San Ildefonso. Analyses of soil and vegetation collected from the perimeter of Area G have shown concentrations of radionuclides greater than background concentrations established for northern New Mexico. As a result, Pueblo residents had become concerned that contaminants from Area G could enter tribal lands through various ecological pathways. The residents specifically questioned the safety of consuming meat from elk and deer that forage near Area G and then migrate onto tribal lands. ...

1999-09-01

209

Development of functional foods for radiation workers  

Energy Technology Data Exchange (ETDEWEB)

In searching modulators of immunity and hematopoiesis among natural products, being used as foods, six herbs exhibited lymphocyte proliferation in vitro, and six exhibited augmentation of hematopoietic cell growth. The combined treatments showed synergistic effects of lymphocyte proliferation and of hematopoietic cell growth. On the other hand, we found four effective oriental medicinal prescriptions, used as energy tonic or blood-building decoctions, for survival and regeneration of hematopoietic cells and for protection of stem cells of intestinal crypt in irradiated mice. On the basis of these results, extracts from combinations of herbs were made in expectation of higher effects in the three respects. In immuno modulation activity by the two combinations of herbs was confirmed in mice. In culture of bone narrow cells, growth improvement of non-adherent precursor and induction of cytokine expression by herb mixture extracts were observed. In evaluation of ...

2000-03-01

210

Radioanalytical chemistry. Vol. 2  

International Nuclear Information System (INIS)

This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).

1989-01-01

211

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

212

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

213

Investigation of radiation defects in solids using the EXAFS method  

International Nuclear Information System (INIS)

The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons.

1978-02-15

214

Evaluation of radiation resistance of cable connector material  

Energy Technology Data Exchange (ETDEWEB)

Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.

2002-10-01

215

On Sensitivity of Spectral Radiative Fluxes to Atmospheric Water Vapor in the 940 nm Region (Numerical Simulation)  

Energy Technology Data Exchange (ETDEWEB)

Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...

2005-03-18

216

Measurements of x-ray radiation dose levels during radiological examination in Jos university teaching hospital and Plateau state specialist hospital  

International Nuclear Information System (INIS)

In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.

2008-10-15

217

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

218

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is ...

1980-01-01

219

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation ...

1995-10-01

220

Short-term inhibition of ADP-induced platelet aggregation by clopidogrel ameliorates radiation-induced toxicity in rat small intestine.  

Science.gov (United States)

Endothelial dysfunction and increased platelet aggregation may be involved in the pathogenesis of normal tissue radiation toxicity. This study assessed clopidogrel, an inhibitor of ADP-induced platelet aggregation, as a modulator of intestinal radiation injury (radiation enteropathy). Rat small intestine was exposed to 21 Gy X-radiation. Clopidogrel (20 mg/kg/day) or vehicle was administered from 2 days before to 10 days after irradiation. Structural radiation injury, neutrophil infiltration, smooth muscle cell proliferation, collagen content, and TGF-beta1 expression were assessed 2 weeks (early phase) and 26 weeks (delayed phase) after irradiation, using quantitative histology and immunohistochemistry, morphometry, and real-time fluorogenic probe RT-PCR. Irradiated intestine exhibited significant histopathologic injury, reduced mucosal surface area, vascular sclerosis, intestinal ...

2002-01-01

221

Physical, biochemical and physiological effects of ultraviolet radiation on Brassica napus and Phaseolus vulgaris  

International Nuclear Information System (INIS)

In order to follow some of the changes induced by ultraviolet-B (UV-B, 280-320 nm) radiation in Phaseolus vulgaris and Brassica napus, experiments were designed to localize sites of changes in leaves and to correlate some of the physiological and biochemical changes with penetration of UV-B radiation. B.napus was exposed to 8.9 kJ m"-"2 day"-"1 biologically effective UV-B radiation (UV-B_B_E). The penetration of UV-B radiation into the leaf was followed using a quartz fibre optic microprobe. Monochromatic radiation at 310 nm was decreased by ca 50 and 34% in the adaxial and abaxial epidermis, respectively, in plants not exposed to UV-B, whereas the radiation was decreased by ca 70 and 42%, respectively, in the same region in UV-treated plants. Polychromatic radiation showed a wavelength dependent change mainly for the collimated ...

1991-11-05

222

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

223

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal ...

1986-01-01

224

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

225

Basic mechanisms of radiation effects in the natural space radiation environment  

Energy Technology Data Exchange (ETDEWEB)

Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)

1994-06-01

226

Visible-light resin-curing units: retinal hazards and protective lenses. Final report, December 1982-May 1986  

Energy Technology Data Exchange (ETDEWEB)

The potential retinal hazard of dental visible-light photopolymerization units and the efficacy of protective lenses for reducing the potential hazards were assessed. The spectral radiance profiles of 11 visible-light photopolymerization units were measured; and the results were then weighted according to the American Conference of Governmental Industrial Hygienists (ACGIH) Blue Light and Thermal Hazard Functions. The results indicate that there are no thermal hazards to the retina even for the worst case condition. None of the blue-light hazard maximum permissible exposure times is short enough to be of concern unless the individual operator chooses to focus on the light source for an extended period. Those individuals who elect to stare at the light during curing procedures should consider the purchase of protective lenses. The special transmission profiles of 16 protective lenses were ...

1986-11-01

227

Environmental protection, environmental pollution, and economic growth. A contribution to environmental economy in the framework of neoclassic models of growth. Umweltschutz, Umweltverschmutzung und Wirtschaftswachstum. Ein Beitrag zur Umweltoekonomie im Rahmen neoklassischer Wachstumsmodelle  

Energy Technology Data Exchange (ETDEWEB)

This book is mainly a comparison of the cost of pollution with the cost of environmental protection. As to the causes of pollution, a difference is made between pollutants that accumulate and pollutants that do not accumulate. Because of pollutant accumulation it is necessary to carry out both subsequent pollution abatement measures and to take preventive action which helps to avoid pollutant emission. Growth models serve to substantiate why such preventive action is both ecologically and economically useful as a rule. Finally the study makes a comparison between some tools of environmental protection. It stresses in particular that, if a duty on emissions is levied, the polluter has to bear all the cost of the pollution, while at the same time the quality of the environment can be more successfully improved than by emission standards alone.

1986-01-01

228

Relaxation oscillation of amplified spontaneous radiation pulse emitted from a single-mirror Cu/CuBr laser  

Energy Technology Data Exchange (ETDEWEB)

The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.

1985-10-01

229

Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note  

Energy Technology Data Exchange (ETDEWEB)

The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.

1986-01-01

230

Pitting corrosion of nickel base alloys in halide media  

International Nuclear Information System (INIS)

A computerized corrosion measuring system (EG and G model 350 A) was used to study the influence of Cr, Mo, Ti, Nb and W on the pitting corrosion of nickel base alloys in 3% NaCl at 90"0C. The electrochemical parameters under investigation are the corrosion potential E_c_o_r_r, pitting potential E_p and protection potential E_p_p. The corrosion behaviour of nickel base alloys were studied by using pitting scan and potentiostatic techniques. Values of corrosion potential, pitting potential and protection potential were used for a ranking of alloys for corrosion resistance.

1988-03-06

231

Corrosion 2003. Conference papers on CD-ROM  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.

2003-07-01

232

Bechtel Hanford Inc. Network Security Plan for the EnvironmentalRestoration Contract  

Science.gov (United States)

'As part of the Computer Protection Plan, this Network Security Plan identifies the specific security measures used to protect Bechtel Hanford, Inc.'s (BHI's) enterprise network. The network consists of the communication infrastructure and information systems used by BHI to perform work related to the Environmental Restoration Contract (ERC) at the Hanford Site. It provides electronic communication between the ERC-leased facilities in Richland, Washington, and facilities located on the Hanford Site. Network gateways to other site and offsite networks provide electronic communication with the remainder of the Hanford community.'

1999-06-30

233

Training And Education Needs In Radiological Protection - First Results Of The ENETRAP Survey  

Energy Technology Data Exchange (ETDEWEB)

Recent studies have shown that there is a wide variety of approaches to education and training of the Qualified Expert across the European Union. National education and training programmes show often large differences in content, duration, level, the introduction of practical work, etc. As they stand, such differences are a barrier to the mutual recognition of the Qualified Expert status and, in part, are contributing to a perceived shortage in expertise in radiation protection and safety. The overall aim of ENETRAP is to determine mechanisms that in the longer term will facilitate better integration of education and training activities (with a view to mutual recognition across the European Union) and to ensure the ongoing provision of the necessary competence and expertise at the level of the Qualified Expert. The ENETRAP project is a 6FP coordination action. It started in April 2005 and runs over a period of 24 months. (authors)

2006-07-01

234

Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 1, Third comparison with 40 CFR 191, Subpart B  

Energy Technology Data Exchange (ETDEWEB)

Before disposing of transuranic radioactive wastes in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments of the WIPP for the DOE to provide interim guidance while preparing for final compliance evaluations. This volume contains an overview of WIPP performance assessment and a preliminary comparison with the long-term requirements of the Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B).

1992-12-01

235

Low-level radioactive waste disposal in the oceans  

Energy Technology Data Exchange (ETDEWEB)

A strategy for the management of the disposal of low-level radioactive wastes into coastal zones and ocean waters has developed over the past three decades. While there has been a substantial increase in the number of international and required agreements there has also been a concomitant improvement in our understanding of the ocean and the processes at work within it. This has allowed more rigorous and reliable assessments to be made of the radiological consequences. With the continued development of basic guidelines of radiological protection by the International Commission on Radiological Protection (ICRP) methodologies have been formulated to derive the fundamental scientific requirement - the relationship between disposal or release rate to the ocean and the resultant radiation dose to exposed human populations.

1983-04-01

236

Irradiation of human insulin in aqueous solution, first step towards radiosterilization  

British Library Electronic Table of Contents (United Kingdom)

The degradation of irradiated human insulin in aqueous solutions was investigated in order to protect the protein against ionizing radiation. The influence of the drug concentration, excipients and irradiation temperature were studied.Aqueous solutions at pH 2 were irradiated by gamma rays or by accelerated electrons. Two different high-performance liquid chromatography (HPLC) methods were used: reverse-phase high-performance liquid chromatography (RP-HPLC)/UV and size exclusion liquid chromatography (SEC/UV) to investigate both the fragmentation and the formation of higher molecular weight proteins.In solution without excipients irradiated at ambient temperature at 10kGy, the loss of human insulin is almost complete. Addition of radio-protecting excipients (free radicals scavengers) and c...

2007-01-01

237

Disposal of old heads for Daya Bay NPP  

International Nuclear Information System (INIS)

The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding package was designed ...

238

CHEMICAL TECHNOLOGY DIVISION, UNIT OPERATIONS SECTION MONTHLY PROGRESS REPORT, JULY 1960  

Science.gov (United States)

A critical review of the literature revealed no experiments on uranyl ion transfer from an aqueous to a tributyl phosphate phase which positively measured the kinetics of the chemical reaction at the interphase. Drawing isorhythmic lines on a three component diagram gives a complex correlation for the compaction of three sizes of glass beads. Neither the use of thoria sols nor high feed solution concentrations of thorium nitrate gave any significant increase in mean particle diameters over those obtained from nitrate solutions of lower concentrations in flame denitration. A hydraulic film resistance has been detected in the anion exchange of uranyl sulfate into Dowex 2lK, and chloride elution was found to give a higher apparent uranium diffusion coefficient than nitrate elution. The rate of dissolution of mixed thorium-uranium oxides was determined as a function of the per cent of mixed oxides dissolved. Mixing in tanks packed with ...

1960-10-27

239

Rayleigh scattering of Moessbauer radiation in hyaluronate oriented fibres  

Energy Technology Data Exchange (ETDEWEB)

The Rayleigh scattering of Moessbauer radiation has been measured on highly oriented fibres of Na-hyaluronate at different hydration levels. The elastic- and-inelastic-scattering intensities, measured as a function of the scattering vector Q, have provided information on the dynamic structuring of the water molecules to the polysaccharidic chains.

1996-02-01

240

Measurement of radiative, Auger, and nonradiative currents in 1. 3-. mu. m InGaAsP buried heterostructure lasers  

Energy Technology Data Exchange (ETDEWEB)

Frequency response measurements are used to determine the carrier lifetime of 1.3-..mu..m InGaAsP buried heterostructure lasers between 1 mA and threshold. The data confirm previous results on the radiative and Auger recombination coefficients and reveal the presence of a nonradiative current which dominates at low currents and contributes 4 mA at threshold.

1987-02-09

241

Numerical simulation and experiment research of radiation performance in a dish solar collector system  

British Library Electronic Table of Contents (United Kingdom)

The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.

2010-01-01

242

Effect of substrate on the results of measuring coating thickness according to radiation scattered by substrate  

International Nuclear Information System (INIS)

The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.

243

A Year of Radiation Measurements at the North Slope of Alaska Second Quarter 2009 ARM and Climate Change Prediction Program Metric Report  

Energy Technology Data Exchange (ETDEWEB)

In 2009, the Atmospheric Radiation Measurement (ARM) Program and the Climate Change Prediction Program (CCPP) have been asked to produce joint science metrics. For CCPP, the second quarter metrics are reported in Evaluation of Simulated Precipitation in CCSM3: Annual Cycle Performance Metrics at Watershed Scales. For ARM, the metrics will produce and make available new continuous time series of radiative fluxes based on one year of observations from Barrow, Alaska, during the International Polar Year and report on comparisons of observations with baseline simulations of the Community Climate System Model (CCSM).

2009-04-15

244

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) ...

1988-01-01

245

Effect of antioxidants on aging of nuclear plant cable insulation  

International Nuclear Information System (INIS)

The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants ...

246

Validity and sensitivity of a model for assessment of impacts of river floodplain reconstruction on protected and endangered species  

International Nuclear Information System (INIS)

Environmental Impact Assessment (EIA) must account for legally protected and endangered species. Uncertainties relating to the validity and sensitivity of EIA arise from predictions and valuation of effects on these species. This paper presents a validity and sensitivity analysis of a model (BIO-SAFE) for assessment of impacts of land use changes and physical reconstruction measures on legally protected and endangered river species. The assessment is based on links between species (higher plants, birds, mammals, reptiles and amphibians, butterflies and dragon- and damselflies) and ecotopes (landscape ecological units, e.g., river dune, soft wood alluvial forests), and on value assignment to protected and endangered species using different valuation criteria (i.e., EU Habitats and Birds directive, Conventions of Bern and Bonn and Red Lists). The validity of BIO-SAFE has been tested by comparing predicted ...

2006-11-01

247

Overview of the FRG waste package materials corrosion test program  

International Nuclear Information System (INIS)

Presently in the FRG there are essentially three institutions involved in corrosion experiments related to high level waste package materials, namely KfK-INE, Nukem and Bayer Leverkusen. In 1981 KfK-INE started a corrosion test program aiming at the selection of suitable canister materials for vitrified high level waste. The program encompassed electrochemical investigations, which were concluded in 1984. Moreover field corrosion tests and laboratory experiments were initiated, and are still ongoing. Several possible canister materials such as mild steel, Ti-Pd-alloy, Hastelloy C4 and others were investigated under the influence of varying parameters such as temperature, and radiation. Both Nukem Company and DWK were assigned the responsibility to conceive and develop a cask for the direct final disposal of spent fuel assemblies. Two solution turned out as most promising for corrosion protection of final disposal casks: (1) ...

1988-03-08

248

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted ...

249

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw ...

1998-02-01

250

Self-assessment of current knowledge in nuclear medicine (second edition)  

Energy Technology Data Exchange (ETDEWEB)

In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...

1981-01-01

251

Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign  

Energy Technology Data Exchange (ETDEWEB)

Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also ...

2007-08-01

252

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when ...

1995-08-01

253

Low dose effects - is the fear more dangerous than the radiation?  

Energy Technology Data Exchange (ETDEWEB)

The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic Linear Hypothesis. ...

1996-01-01

254

Evaluation of Reports on Environmental Measurements of Electromagnetic Fields Generated by High Voltage Transmission Lines and Substations  

International Nuclear Information System (INIS)

This paper presents some situations, in which measurements of electromagnetic fields generated by transmission lines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmission lines. To verify the measurement results, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the ...

2007-01-01

255

Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand the functions of the existing PPS composed of physical areas and Protection ...

2006-07-01

256

Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant  

International Nuclear Information System (INIS)

The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand the functions of the existing PPS composed of physical areas and Protection ...

2006-05-25

257

Performance Assessment of Physical Protection System at Wolsong Nuclear Power Plant using SAVI code  

Energy Technology Data Exchange (ETDEWEB)

The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several techniques are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsong NPP using SAVI code. The first is that the SAVI constructs the site-specific Adversary Sequence Diagram (ASD) of the PPS. This provides a methods of graphically representing the PPS composed of physical areas and ...

2005-07-01

258

Noise spectral density measurements of a radiation hardened CMOS process in the weak and moderate inversion  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the noise of MOS transistors of the United Technology Microelectronics Center (UTMC) 1.2 [mu]m radiation hardened CMOS P-well process from the weak to moderate inversion region. The noise power spectral densities of both NMOS and PMOS devices were measured from 1 KHz to 50 MHz. The bandwidth was chosen such that the important components of the spectral densities such as the white thermal noise and the 1/f noise could be easily resolved and analyzed in detail. In this paper the effects of different device terminal DC biases and channel geometries on the noise are described.

1992-08-01

259

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the ...

260

IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4  

Science.gov (United States)

Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)

1961-01-01

261

Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization  

CERN Document Server

Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the potential and the ...

2005-01-01

262

A.C.R.O. activity report 2005; ACRO rapport d'activite 2005  

Energy Technology Data Exchange (ETDEWEB)

The A.C.R.O. is an association law 1901 declared at the Calvados prefecture at the date of 14. october 1986 and registered as environment protection. It was created, by more than 900 persons, in the months following the Chernobylsk accident in reaction to a lack of information and means of independent radiation monitoring. The particularity of the association is to own a laboratory of radioactivity analysis. Since the end of the nineties, the concerns include the natural sources of irradiation as the radon and apply to the consequences, out of nuclear industry, of the use of ionizing radiation or radioactive matter. On this last point, the affair of the orphan industrial site Bayard at Saint-Nicolas-d'Aliermont, massively contaminated by radium-226 devoted to the fabrication of alarm clocks, and the appearance of exemption threshold in the European law are elements at the origin of this evolution. (N.C.)

2006-07-01

263

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

264

The effective per caput dose equivalent as a measure of medical radiation exposure of the population - a complement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population exposure to different ...

1984-01-01

265

The radiological accident in Tammiku  

International Nuclear Information System (INIS)

On 21 October 1994, three brothers entered a waste repository at Tammiku, Estonia, without authorization and removed a metal container enclosing a caesium-137 source. During the removal the source was dislodged and fell to the ground. One of the men picked up the source, placed it in his pocket and took it to his home in the nearby village of Kiisa. Very soon after entry into the repository he began to feel ill, and few hours later he began to vomit. The man was subsequently admitted to hospital with severe injuries to his leg and hip and died on 2 November 1994. The injury and subsequent death were not attributed to radiation exposure, and the source remained in the man's house with his wife and stepson and the boy's great-grandmother. The boy was hospitalized on 17 November with severe burns on his hands, and these were identified by a doctor as radiation induced. The authorities were alerted, and the Estonian Rescue Board recovered the ...

266

On-site radiation exposure in severe reactor accidents: Scoping study  

Energy Technology Data Exchange (ETDEWEB)

The results of a scoping study of onsite radiation exposures which could take place in each of three types of postulated reactor accidents are presented. The accident types are (1) a fuel handling accident at a Mark III BWR; an interfacing system LOCA or V sequence at a PWR; and and Anticipated Transient Without Scram (ATWS) at a Mark I BWR. Both external and internal dose pathways are considered. The results of the study indicate the prohibitively high radiation doses could be received in some plant areas if personnel were to remain there. However, times of the order of a few minutes to a few hours, depending on the type of accident, would be available before life-threatening doses would be accumulated assuming that the provided full face respiratory protection equipment were used promptly. Special attention was given radiation doses possibly received by control room personnel for several control room ...

1990-09-01

267

Protection Against Benzene Toxicity  

Science.gov (United States)

Leukemia; Aplastic Anemia

2005-06-23

268

Towards optimal use of available technical resources for regulatory purposes. The Syrian experience  

International Nuclear Information System (INIS)

The Atomic Energy commission of Syria (AECS) is nominated by Syrian legislation as the regulatory authority in respect of radiation protection and safety and security of radioactive sources. In addition AECS is providing a wide range of Technical Services (TS) through its various departments. In this paper, the cooperation and coordination between the regulatory authority and the providers of technical services in Syria are described. The adjustment of the regulatory programme as to make maximal use of the available technical resources is presented. It was shown that this relationship does not jeopardize the effective independency of the regulatory authority which is maintained by keeping the regulatory decisions based on pure regulatory considerations. (author)

2007-08-01

269

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

270

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues; Abfaelle mit natuerlicher Radioaktivitaet. Teil 1. Bewertung und Ueberwachung von Materialien und Rueckstaenden  

Energy Technology Data Exchange (ETDEWEB)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far. [German] Die novellierte Strahlenschutzverordnung von 2001 befasst sich auch mit natuerlich vorkommenden radioaktiven Stoffen. Bei ihrer Verwertung oder Beseitigung ergeben sich praktische Fragen, die beachtet werden muessen. Erfahrungen auf diesem Gebiet liegen bisher kaum vor. (orig.)

2003-03-01

271

Inter-comparison of some environmental radioactivity monitoring items for Guangdong Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

This paper introduces the inter-comparison results of some environmental radioactivity monitoring items for Daya Bay nuclear power plant. The inter-comparison was organized by China Institute for Radiation Protection and five laboratories participated in it. The compared items included total #beta# in kelp and sediment, "3H in water, "9"0Sr in soil, artificial nuclides "1"1"0"mAg, "2"4"1Am, "1"0"9Cd, "5"7Co in kelp and sediment. Inter-comparison results are analyzed as well

2003-01-01

272

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

273

Department of Nuclear Safety Research and Nuclear Facilities annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The report presents a summary of the work of the Department of Nuclear Safety Research and Nuclear Facilities in 1995. The department`s research and development activities are organized in three research programmes: Radiation Protection, Reactor Safety, and Radioanalytical Chemistry. The nuclear facilities operated by the department include the Research Reactor DR3, the Isotope Laboratory, the Waste Treatment Plant, and the Educational Reactor DR1. Lists of staff and publications are included together with a summary of the staff`s participation in national and international committees. (au) 5 tabs., 21 ills.

1996-03-01

274

Contribution of the pectin in the cesium elimination in organism. results of analysis on Belarus children; Du role de la pectine dans l'elimination du cesium dans l'organisme. Resultats d'analyses sur des enfants bielorusses  

Energy Technology Data Exchange (ETDEWEB)

The results make appear that the cesium 137 would be eliminated less quick than what the ICRP considered for its models. Pectin would accelerate the cesium elimination but less quick than what is announced by its promotors. Politically speaking, the pectin is ignored by the officials of medicine and radiation protection at the pretext that its efficiency is not proved but no study is made. (N.C.)

2007-07-01

275

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder ...

2003-03-04

276

COMPARISON OF NATURAL BACKGROUND DOSE RATES FOR RESIDENTS OF THE AMARGOSA VALLEY, NV, TO THOSE IN LEADVILLE, CO, AND THE STATES OF COLORADO AND NEVADA  

Energy Technology Data Exchange (ETDEWEB)

In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the dose rate in the two identified areas ...

2006-02-24

277

The Protective Effect of Antioxidants on Oxidative Stress in Rats Exposed to the 950 MHz Electromagnetic Field  

International Nuclear Information System (INIS)

Studies have linked cell phone radiation to health problems such as headaches, high blood pressure, cancer and more. There is a latency period for most diseases and it may take years and more studies before the required weight of evidence is established. But the effects are cumulative and precautions should be taken now before it is too late. The aim of the present study was to investigate if supplementation with antioxidants would protect heart and liver tissues from harmful radiation emitted by cell phone. Thirty two male albino rats were randomly divided into four equal groups: I- Control, II- Antioxidants treated group, III- 950 MHz EMR, IV- 950 MHz EMR + antioxidants. A 950 MHz EMR radiation (217-Hz pulse rate, 2-W maximum peak power, SAR Specific Absorption Rate"1.6 W/Kg) was applied to groups III and IV 60 min/day, for 30 days using an experimental exposure device. Antioxidants supplement ...

278

Chamber technology concepts for inertial fusion energy: Three recent examples  

Energy Technology Data Exchange (ETDEWEB)

The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, while thick liquid layers have the added benefit of protecting structures from fusion ...

1997-02-27

279

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

280

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

281

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

282

Intervention for recovery after accidents  

International Nuclear Information System (INIS)

The purpose of this document is to provide a framework for developing protective strategies in the longer term following an accidental release of radionuclides to the offsite environment. This advice covers all forms and scales of accidental release, including releases from nuclear sites and reactors, weapons accidents, and damaged industrial or medical sealed sources. The countermeasures considered are those intended to protect the public from external irradiation from radionuclides deposited in the environment, from the inhalation of resuspended radionuclides, and from inadvertent ingestion of radionuclides resulting from contact with contaminated surfaces. The Board terms these recovery countermeasures. They can be broadly grouped as either decontamination measures (ie measures that deal directly with the radionuclides, whether by removing them, shielding them or physically or chemically bonding ...

283

Design, manufacturing, installation, protection of 345 kV 750 MVA submarine power cables in New York  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the criteria used for the thermal, electrical, mechanical, hydraulical design of the submarine power cables crossing Long Island Sound to feed New York City. The cables are of the self contained fluid filled (SCFF) type. There is also a description of the special measures adopted to face the exceptionally aggressive environment, due to presence of hydrogen sulphide and of stray currents (caused by electric railways and pipes cathodic protection). The most significant example of such measures is a third sacrificial armour. Four single-core SCFF cables (one spare) were manufactured in Arco Felice (near Naples, Italy), for the New York Power Authority. The average length of the cables is 13 km, jontless. The Italian cable ship 'Giulio Verne', managed by Pirelli, was utilized for the transportation and laying. The ship is equipped with a turntable of 7000 tonnes capacity. The cables are ...

1992-04-01

284

Use of high energy radiation component as a reference source for radiometric testing  

International Nuclear Information System (INIS)

The possibility of providing high accuracy of absorption and albedo methods of radiometric testing due to the use of high-energy radiation component that has passed through a barrier and gone from it in the opposite direction as a reference source, is considered. It is shown that the use of high-energy component of penetrating radiation as a reference source decreases the device response to the main interference in a much larger degree than its response to the change of measured parameter. Experiments are performed using steel pipes and plates. "2"4"1Am, "1"3"7Cs and "6"0Co are used as sources.

285

The effect of temperature on the radiative performance of Ho-YAG thin film selective emitters  

Energy Technology Data Exchange (ETDEWEB)

The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.

1995-01-01

286

Radiological hazards in uranium mines and a yellow-cake plant in Turkey  

Energy Technology Data Exchange (ETDEWEB)

Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.

1984-06-01

287

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

288

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

289

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

290

Overview of bunch length measurements.  

Energy Technology Data Exchange (ETDEWEB)

An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.

1999-02-19

291

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

292

Quantum locking of mirrors in interferometric measurements  

International Nuclear Information System (INIS)

We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.

2004-03-07

293

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

294

Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole  

Energy Technology Data Exchange (ETDEWEB)

Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.

1996-12-31

295

Radiation treatment of some poultry products  

International Nuclear Information System (INIS)

Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.

1988-09-26

296

Radiation treatment of crude drugs. Development of suitable methods of detection. Strahlenbehandlung von Arzneidrogen. Entwicklung geeigneter Nachweismethoden  

Energy Technology Data Exchange (ETDEWEB)

It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).

1992-09-01

297

Investigation of Moessbauer radiation diffraction on Fe/sub 3/BO/sub 6/ monocrystal. Nuclear transition interference  

Energy Technology Data Exchange (ETDEWEB)

Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurement results are compared with theoretical calculations.

1984-05-25

298

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

299

Corrosion studies on selected packaging materials for disposal of high level wastes  

International Nuclear Information System (INIS)

In order to qualify corrosion resistant materials for high level waste (HLW) packagings acting as a long-term barrier in a rock salt repository, the corrosion behaviour of the preselected materials Ti 99.8-Pd, Hastelloy C4 and two unalloyed steels was investigated. The resistance of the materials to general corrosion, local corrosion and stress corrosion cracking was examined under postulated accident conditions in the repository by long-term immersion tests of up to 4 years duration and electrochemical methods. The parameters investigated were different salt brines, temperatures of 90 deg. C, 170 deg. C and 200 deg. C as well as a gamma radiation field of 10"3Gy/h (10"5rad/h). Among the materials studied, Ti 99.8-Pd exhibited the highest corrosion resistance. This material corroded at a very low rate (radiation, and proved to be resistant to local corrosion and stress corrosion cracking. Hastelloy C4 ...

1987-05-01

300

POTENTIATION BY PENTOBARBITAL OF THE PROTECTIVE ...  

Science.gov (United States)

... Accession Number : AD0268549. Title : POTENTIATION BY PENTOBARBITAL OF THE PROTECTIVE EFFECT OF AET AGAINST GAMMA RAYS. ...

1961-10-01

301

Corrosion Protection of special steels and alloys  

International Science & Technology Center (ISTC)

Development of the Corrosion Protection Technology for Special Steels and Alloys

302

Stainless steel acid corrosion inhibition by organic dyes  

Energy Technology Data Exchange (ETDEWEB)

Azobenzene dyes are effective inhibitors for austenitic 304 L and 316 L stainless steel corrosion in high acidic medium up to 7N. A good efficiency is obtained from weight loss and electrochemical Rsub(p) measurements in hydrochloric acid, while no inhibition is observed in sulfuric solutions. Transformation from the primarily azobenzene to other compounds give rise to enhanced protection of steel samples, and probable structures of the inhibiting species are proposed in view of our results.

1983-10-01

303

Stainless steel acid corrosion inhibition by organic dyes  

International Nuclear Information System (INIS)

Azobenzene dyes are effective inhibitors for austenitic 304 L and 316 L stainless steel corrosion in high acidic medium up to 7N. A good efficiency is obtained from weight loss and electrochemical Rsub(p) measurements in hydrochloric acid, while no inhibition is observed in sulfuric solutions. Transformation from the primarily azobenzene to other compounds give rise to enhanced protection of steel samples, and probable structures of the inhibiting species are proposed in view of our results.

304

Position-Dependent Electrostatic Protection against Protein Aggregation  

British Library Electronic Table of Contents (United Kingdom)

Proteins with a high propensity to aggregate can be largely prevented from doing so with surprisingly small changes to their primary structure. By using a combination of rational design and quantitative measurements of aggregation rates, we show that adding a single charge in specific "gatekeeper" regions is sufficient to change the timescale for amyloid fibril growth from minutes to weeks, thereby dramatically reducing the efficiency of this process.

2009-01-01

305

Natural radioactive materials occurrence in oil facilities  

International Nuclear Information System (INIS)

This work presents and describes the natural radioactive occurrence in oil facilities. The origins of the detected radioactivity and the reasons of its settlement are discussed. The measurements results carried out in oil facilities in the Neuquina basin (Argentine) are shown in this work. The aim is to describe the actual situation and to evaluate the magnitude of the problem. Finally, recommendations are proposed to protect the health of the workers, especially of those who carry out the cleaning of the equipment, and to guarantee an appropriate final disposal for the generated radioactive residuals. (author)

2001-06-01

306

Human error and experienced feedback during refuelling overhauling of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The authors describe the various human error encountered during Daya bay refueling overhaul, and the subsequent root cause evaluation and protective measure. Authors consider transparency is the key in reducing human error and event recurrence. Additional y, event transparency will enhance the effectiveness if experience feedback and reduce event consequence

2000-10-01

307

Effects of electromagnetic pollution on human health discussed  

Energy Technology Data Exchange (ETDEWEB)

The harmful effects of high-intensity electric fields on human beings are discussed. Formulas for determining the field strength of high voltage transmission lines and track lines and experimental data of these effects on mice are given. Protective measures from these hazards are introduced. 18 references, 7 figures, 5 tables.

1982-01-01

308

Dispersant Effectiveness Of Heavy Fuel Oils Using The Baffled Flask Test  

Science.gov (United States)

Dispersants have been widely used as a primary response measure for marine oil spills around the world. Recently, the U.S. Environmental Protection Agency (EPA) developed an improved laboratory dispersant testing protocol, called the Baffled Flask Test (BFT). The BFT protocol w...

309

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

310

Assessing the Risks of Sampling Rates for Surveilling a Population  

British Library Electronic Table of Contents (United Kingdom)

Surveillance of a population, such as a weapon stockpile, is needed to discover manufacturing defects as well as deterioration as the population ages. This article considers the risks of sampling rates for surveillance from three perspectives: detection probability of defects in a proportion of a population with pass/fail data, detection of a trend in a defective proportion of the population with pass/fail data, and detection of a trend with quantitative degradation measurements. Understanding of these risks will help the decision maker choose a sampling rate to protect against such problems of a specified size at a tolerable risk.

2011-01-01

311

Metrology measurement capabilities  

Energy Technology Data Exchange (ETDEWEB)

Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. ...

1997-06-01

312

Structural and functional aspects of radiation adrenalopathy  

Energy Technology Data Exchange (ETDEWEB)

As part of a combined study of the responses of the mouse adrenal gland and kidney to X-irradiation, the weight of adrenal glands, the relative volumes of the cortex and medulla and the aldosterone output were measured at predetermined times after irradiation of the left organs only.

1986-01-01

313

STS-83 - Johnson Space Center - NASA  

Science.gov (United States)

Radiation Measurement in Crew Compartment. DTO 805: .... spacecraft and aircraft propulsion, and hazardous waste disposal. ...... combustion reactions in a turbulent chemical kinetic flow reactor using laser induced fluorescence and ...

314

SEE Characterization of the Samsung K4F660812 DRAM ... - NEPP - NASA  

Science.gov (United States)

the Samsung K4F660812 DRAM were measured by the JPL Radiation Effects. Group [1] . ... The Samsung K4F660812 is a 8 x 223 bit Fast Page CMOS DRAM. The two- ...

315

Emergency Reference Levels: Criteria for Limiting Doses to the Public in the Event of Accidental Exposure to Radiation.  

Science.gov (United States)

Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...

1981-01-01

316

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been ...

1997-07-01

317

Control of anodic passivation systems  

Energy Technology Data Exchange (ETDEWEB)

A method is described of controlling an anodic protection system in a heat exchanger comprising: (a) installing at least one cathode within the heat exchanger, at least one cathode being aligned with the longitudinal axis of the heat exchanger and extending substantially along the length of the heat exchanger; (b) installing a first reference electrode within and at one end of the heat exchanger, the first reference electrode having a first controller having a set point for control and a power supply having an output creating an electrical potential between at least one cathode and the heat exchanger; (c) measuring the electrical potential of the heat exchanger with the first reference electrode; (d) operating the first controller in response to measurements made by the first reference electrode to change the output of the power supply; (e) installing a second reference electrode within and at the opposite end of the heat ...

1987-08-25

318

Regulatory view of the close-out of the uranium ore mine Zirovski Vrh  

International Nuclear Information System (INIS)

The production of the uranium mine Zirovski Vrh ceased in 1990. The main remaining problem of the remadiation are mine and mill tailings. The uranium mine Zirovski Vrh has one mill tailings site Borst and one waste pile Jazbec. According to the Act on protection against ionising radiation and nuclear safety which was adopted by the Parliament in 2002, they are classified as radiation facilities. Slovenian Nuclear Safety Administration (SNSA) is authorised for issuing a mandatory consent to mining work. The SNSA prepared the initial proposal of content of the safety report for the mine waste pile Jazbec. In 2005, according to the detailed content of this document, the public company Zirovski Vrh Ltd prepared the safety report which was examined by an authorised expert for radiation and nuclear safety. After a careful revision of the safety evaluation report, the consensus for mining work shall be issued ...

2005-09-05

319

Radiolytic stabilization of poly(methyl methacrylate) using commercial additives; Estabilizacao radiolitica do poli(metacrilato de metila) usando aditivos comerciais  

Energy Technology Data Exchange (ETDEWEB)

Poly(methyl methacrylate), PMMA, Acrigel, a Brazilian polymer, is used in the manufacture of medical supplies sterelizable by ionizing radiation. However, when PMMA is gamma-irradiated it undergoes main chain scissions, which promote molecular degradation causing reduction in its mechanical properties. Therefore, radiolytic of PMMA is important for it to become commercially radiosterizable. In this work some commercial additives, originally used in photo-and thermo-oxidate stabilization of polymers, were tested. Only two additives, type HALS (Hindered Amine Light Stabilizer), denoted Scavenger, showed a good protective quality. The investigation of radiation-induced main scissions was carried out by viscosimetric method. The most effective additive, added to the polymer system at 0.3 w/w%, promotes a great molecular radioprotection of 93%. That means a reduction of G-value (scissions/100 eV) from 0.611 to 0.053. In ...

2000-04-01

320

Effects of gamma and electron beam irradiation on the properties of calendered cord fabrics  

Energy Technology Data Exchange (ETDEWEB)

The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that PET calendered fabric has higher resistance to ionizing radiation. Ny 6 and Ny 66 calendered fabrics are ...

2010-03-15

321

Annual report 2005-2006  

International Nuclear Information System (INIS)

Research and development and other activities of the various constituent units of Department of Atomic Energy (DAE) and also of the institution aided by DAE for the year 2005-2006 are reported. The various constituents units of DAE consist of nuclear research centres, nuclear power stations, fuel reprocessing and heavy water plants, nuclear fuel fabrication facilities, electronic and instrumentation production organisations, atomic mineral processing units and other nuclear installations. The activities of DAE cover the whole gamut of nuclear fuel cycle, research and development in nuclear science and reactor technology, applications of radiation and radioisotopes, radiation protection, research and development in front line areas such as robotics, lasers, mathematics and computational sciences. International research collaborations like CERN-DAE collaboration were completed by BARC. These activities are described broadly ...

322

Environmental survey of former royal artillery range hebrides  

International Nuclear Information System (INIS)

Full text of publication follows: The former UK Royal Artillery Range, Hebrides had been used to store and use radioactive miss distance indicators (R.A.M.D.I.) in the testing of Rapier missiles. As part of the testing, missiles were fired out to sea between about 1970 and 1981. Concerns were expressed in early 2004 by some within the local community that there was an unknown, ongoing hazard to them from the impact on the local environment resulting from the use radioactive material in these trials. Accordingly Defence Science and Technology Laboratory, Environmental Science Department (D.s.t.l. E.S.D.) were tasked by the Ministry of Defence to carry out an Environmental Survey of the former Royal Artillery Range, Hebrides and surrounding areas; the environmental survey was carried between the dates of 18 28 May 2004. D.s.t.l. E.S.D. environmental survey focussed upon buildings and areas within and immediately adjacent to the Range Compound, launch areas, and the burial site used ...

2006-05-15

323

Secondary hazards of high power laser beam welding  

International Nuclear Information System (INIS)

Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)

1996-01-01

324

Forward directed Smith-Purcell radiation from relativistic electrons  

International Nuclear Information System (INIS)

The requirements for the generation of forward directed Smith-Purcell emission from relativistic electrons are introduced, and the first experimental evidence of this phenomenon is presented. The experiments were conducted with a 2.8 MeV/c electron beam interacting with a 1 cm period grating. Radiation emitted in two bands with wavelengths ranging from 600 to 650 #mu#m and 1.2 to 1.7 mm were measured. Grating period to wavelength ratios were as high as 16. The measured intensities are higher than that predicted by incoherent emission.

325

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

326

The protective role of ceramic filters against natural radioactivity of water  

International Nuclear Information System (INIS)

The paper presents results of measurements of the natural radioactivity of tap water where samples were taken in front of, and behind the ceramic filter commonly used in houses for the purification of tap water. Altogether, 289 samples were taken, processed and measured during 1985-1986 in Kuwait. Results reveal the fact that ceramic filters reduce substantially the natural radioactivity in water (the 'gross' alpha activity reduced by the factor 2.18 #+-# 18%; the 'gross' beta by 1.53 #+-# 1.6%. (author).

327

Radiation: how safe is safe?  

International Nuclear Information System (INIS)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).

1993-05-01

328

Radiation: how safe is safe  

Energy Technology Data Exchange (ETDEWEB)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).

1993-05-15

329

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

330

Effect of decrease of molybdenum radiation hardening at high energy proton irradiation  

International Nuclear Information System (INIS)

By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.

1990-05-22

331

Coherent spontaneous radiation from highly bunched electron beams  

International Nuclear Information System (INIS)

Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10"4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques.

1995-08-21

332

Valence mixing in rare earth compounds  

International Nuclear Information System (INIS)

The concepts of ''fast'' and ''slow'' time scale valence measurements are emphasized by a comparison of L/sub III/ absorption and Mossbauer effect measurements on the temperature induced valence change in EuPd/sub 2/Si/sub 2/. Further the authors show how synchrotron radiation based L/sub III/ measurements of the Ce-valence state can be used to demonstrate electronic structure trends under wide changes in chemical environment. The purpose of this paper is to provide an introduction to researchers in the People's Republic of China to the field of mixed valent rate earth compounds. They hope to illustrate some of the basic concepts in this field, how the field is contributing to the overall insight into the chemical physics of solids and finally how synchrotron radiation measurements in particular are playing a key role in this field.

333

Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this ...

1982-01-01

334

The natural background approach to setting radiation standards  

International Nuclear Information System (INIS)

The suggestion has often been made that an additional radiation exposure imposed on humanity as a result of some important activity such as electricity generation would be acceptable if the exposure was 'small' compared to the natural background. In order to make this concept quantitative and objective, we propose that 'small compared with the natural background' be interpreted as the standard deviation (weighted with the exposed population) of the natural background. We believe that this use of the variation in natural background radiation is less arbitrary and requires fewer unfounded assumptions than some current approaches to standard-setting. The standard deviation is an easily calculated statistic that is small compared with the mean value for natural exposures of populations. It is an objectively determined quantity and its significance is generally understood. Its determination does not omit any of the pertinent data. When this method ...

1979-03-09

335

Some aspects of concentrated sulphuric acid storage tank corrosion  

Energy Technology Data Exchange (ETDEWEB)

Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. It was concluded that corrosion-induced leaks can be prevented by using anodic protection and baked phenolic coating technologies. 23 refs., 9 ...

2009-07-01

336

One-way quantum computing in a decoherence-free subspace  

Energy Technology Data Exchange (ETDEWEB)

We introduce a novel scheme for one-way quantum computing (QC) based on the use of information encoded qubits in an effective cluster state resource. With the correct encoding structure, we show that it is possible to protect the entangled resource from phase damping decoherence, where the effective cluster state can be described as residing in a decoherence-free subspace (DFS) of its supporting quantum system. One-way QC then requires either single or two-qubit adaptive measurements. As an example where this proposal can be realized, we describe an optical lattice set-up where the scheme provides robust quantum information processing. We also outline how one can adapt the model to provide protection from other types of decoherence.

2007-06-15

337

Investigations of microstructure of thin TbFeCo films by high-resolution electron microscopy  

International Nuclear Information System (INIS)

High-resolution electron microscope observations confirm the presence of small crystallites in thin TbFeCo films protected by Si_3N_4 overcoats. Selected area electron diffraction patterns in top-view projection indicate that the crystals have a face-centered-cubic structure. Microscope analysis reveals grain growth following annealing of these protected thin films at 200 degree C in vacuum, and Kerr measurements yield large reductions in coercivity relative to the room-temperature value. The typical grain size visible in top-view observations increases from about 3 nm in the as-deposited samples to about 30 nm after annealing at 200 degree C for 36 h while the static coercivity, H_c, drops by about 40%. The fcc structure of the crystals is retained after annealing.

338

Fundamental aspects of fault location algorithms used in distance protection  

Energy Technology Data Exchange (ETDEWEB)

Considers fundamental problems involved in the precise location of faults on high-voltage transmission lines. The influence of pre-fault load on the distance-to-fault measurement problem is analysed and a new method of accounting for load effects is presented. Two of the algorithms considered are precise, containing no simplifyng assumptions and their overall accuracy is limited only by the accuracy of digital impedance relays at both ends of the protected circuit. A third algorithm presents a new approach to the fault location problem, which requires digital impedance relays at one end only of a transmission line. The procedures described are applicable to any system arrangement and are suitable for a wide range of fault resistance values.

1986-09-01

339

Photoluminescence in large fluence radiation irradiated space silicon solar cells  

Energy Technology Data Exchange (ETDEWEB)

Photoluminescence spectroscopy measurements were carried out for silicon 50{mu}m BSFR space solar cells irradiated with 1MeV electrons with a fluence exceeding 1 x 10{sup 16} e/cm{sup 2} and 10MeV protons with a fluence exceeding 1 x 10{sup 13} p/cm{sup 2}. The results were compared with the previous result performed in a relative low fluence region, and the radiation-induced defects which cause anomalous degradation of the cell performance in such large fluence regions were discussed. As far as we know, this is the first report which presents the PL measurement results at 4.2K of the large fluence radiation irradiated silicon solar cells. (author)

1997-03-01

340

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

341

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

342

Measurement of the ratio of liquid to solid phases in a continuous ingot  

International Nuclear Information System (INIS)

A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous ...

343

Irradiation effects on the electrochemistry and corrosion resistance of stainless steel  

International Nuclear Information System (INIS)

Nickel ion radiation at 500 C was shown to have a strong effect on the surface electrochemistry and intergranular corrosion (IGC) of stainless steel (SS). Measured current densities in a 1 N sulfuric acid solution at room temperature were increased at active-passive, passive, and transpassive potentials. Radiation effects on the current decay behavior and susecptibility to IGC were similar for a fine-grained (FG) S alloy and for a very large-grained (LG) SS. Radiation-induced segregation (RIS) at the surface was believed to promote higher currents at short times, whereas segregation at grain boundaries was responsible for IG attack. Analytical electron microscopy (AEM) measurements revealed chromium and iron depletion plus Ni and silicon enrichment at grain boundaries in irradiated specimens. Si enhanced dissolution at transpassive potentials, whereas Cr depletion did the same at ...

1995-01-01

344

Detached divertor plasmas in JET  

Energy Technology Data Exchange (ETDEWEB)

In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.

1994-07-01

345

The Importance of Building and Enhancing Worldwide Industry Cooperation in the Areas of Radiological Protection, Waste Management and Decommissioning  

International Nuclear Information System (INIS)

The slow or stagnant rate of nuclear power generation development in many developed countries over the last two decades has resulted in a significant shortage in the population of mid-career nuclear industry professionals. This shortage is even more pronounced in some specific areas of expertise such as radiological protection, waste management and decommissioning. This situation has occurred at a time when the renaissance of nuclear power and the globalization of the nuclear industry are steadily gaining momentum and when the industry's involvement in international and national debates in these three fields of expertise (and the industry's impact on these debates) is of vital importance. This paper presents the World Nuclear Association (WNA) approach to building and enhancing worldwide industry cooperation in radiological protection, waste management and decommissioning, which is manifested through the activities of the two WNA working groups ...

346

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may ...

1993-03-01

347

Radiation resistance of nylon. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in vacuum, nylon 12 was superior to nylon 6, ...

1983-12-01

348

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, ...

1992-10-25

349

Average neutron resonance parameters and radiative capture cross sections for the isotopes of molybdenum  

International Nuclear Information System (INIS)

The neutron capture cross sections of the stable molybdenum isotopes have been measured with high energy resolution (#DELTA#E/E < approximately 0.2%), between 3 and 90 keV neutron energy, at the 40 m station of ORELA. Average resonance parameters are extracted for s- and p-wave resonances. The s-wave neutron strength function is close to 0.5x10"-"4 for all isotopes, but the p-wave strength function exhibits a well defined peak near A approximately 95. Both s- and p-wave radiative widths decrease markedly as further neutrons are added to the closed shell. The p-wave radiative widths are generally greater than the s-wave widths showing the presence of non-statistical #gamma#-decay mechanisms. Valence neutron theory fails to explain the magnitude of the p- to s-wave radiative width disparity and doorway state processes are invoked. In particular, the data for "9"8Mo appear to violate the usual valence ...

350

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber ...

2007-08-21

351

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

352

Protective efficiency of dendrosomes as novel nano-sized adjuvants for DNA vaccination against birch pollen allergy  

British Library Electronic Table of Contents (United Kingdom)

We evaluated the use of a novel gene porter (Den123-a nontoxic self-assembled dendritic spheroidal nanoparticle made of biodegradable monomers), aiming to enhance and improve the desired immune response in protection from allergy. Footpad DNA immunization in Balb/c mice was done three times using the Bet v 1a gene with or without Den123 with 2-week intervals followed by sensitization with rBetv1 (5mg) in alum twice in a weekly interval. Different doses of pCMV-Betv1 were used (10mg and 100mg). The protective role of different formulations was evaluated by measuring the IgG1, IgG2a and IgE antibody production, cytokine release of isolated splenocytes and b-hexosaminidase release from the RBL cells. Higher and increasing ratios of IgG2a/IgG1 were seen in mice which received plasmids in combi...

2006-01-01

353

Aging, tumor suppression and cancer: High-wire act!  

Energy Technology Data Exchange (ETDEWEB)

Evolutionary theory holds that aging is a consequence of the declining force of natural selection with age. We discuss here the evidence that among the causes of aging in complex multicellular organisms, such as mammals, is the antagonistically pleiotropic effects of the cellular responses that protect the organism from cancer. Cancer is relatively rare in young mammals, owing in large measure to the activity of tumor suppressor mechanisms. These mechanisms either protect the genome from damage and/or mutations, or they elicit cellular responses--apoptosis or senescence--that eliminate or prevent the proliferation of somatic cells at risk for neoplastic transformation.We focus here on the senescence response, reviewing its causes, regulation and effects. In addition, we describe recent data that support the idea that both senescence and apoptosis may indeed be the double-edged swords predicted by the evolutionary hypothesis ...

2004-08-15

354

Precision Measurement of the Undulator K Parameter using Spontaneous Radiation  

Energy Technology Data Exchange (ETDEWEB)

Obtaining precise values of the undulator parameter, K, is critical for producing high-gain FEL radiation. At the LCLS [1], where the FEL wavelength reaches down to 1.5 {angstrom}, the relative precision of K must satisfy ({Delta}K/K){sub rms} {approx}< 0.015% over the full length of the undulator. Transverse misalignments, construction errors, radiation damage, and temperature variations all contribute to errors in the mean K values among the undulator segments. It is therefore important to develop some means to measure relative K values, after installation and alignment. We propose a method using the angle-integrated spontaneous radiation spectrum of two nearby undulator segments, and the natural shot-to-shot energy jitter of the electron beam. Simulation of this scheme is presented using both ideal and measured undulator fields. By ...

2007-04-17

355

Characterization of Radiation Instruments at the Summit of Mt. Fuji  

International Nuclear Information System (INIS)

The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically ...

2010-12-01

356

Radon concentration measurements in the Amasra coal mine, Turkey  

Energy Technology Data Exchange (ETDEWEB)

In this study, the results of atmospheric radon measurements that were performed for the Amasra underground coal mine in Zonguldak bituminous coal basin (Turkey) are presented. The radon measurements were performed for 40 days between November 2004 and December 2004 using passive nuclear etched track detectors. The radon concentrations vary from a minimum value 49 Bq m{sup -3} in a site located at +40 m to a maximum value 223 Bq m{sup -3} in a site located at -100 m. Mean concentration is 117 (Bq m{sup -3}). This value is well below the action level of 500-1500 Bq m{sup -3} recommended by the International Commission on Radiological Protection (ICRP) (1993). The mean effective dose value for workers of this mine of 3.4 {mu} Sv per day was obtained. This result shows that protection against radiological hazards would not be necessary for workers of this mine.

2006-04-15

357

Technology development, evaluation, and application (TDEA) FY 1997 progress report  

Energy Technology Data Exchange (ETDEWEB)

The public expects that the Los Alamos National Laboratory (LANL) will operate in a manner that prevents negative impacts to the environment and protects the safety and health of its employees and the public. To achieve this goal within budget, the Department of Energy (DOE) and LANL must develop new and improved environment, safety, and health (ES and H) technologies and implement innovative, more cost-effective ES and H approaches to operations. In FY95, the Environment, Safety, and Health (ESH) Division initiated a Technology Development, Evaluation, and Application (TDEA) program. The purpose of this unique program is to test and develop technologies that solve LANL ES and H problems and improve the safety of LANL operations. This progress report presents the results of 10 projects funded in FY97 by the TDEA Committee of the Environment, Safety, and Health Division. Products generated from the projects funded in FY97 included implementation of ...

1998-05-01

358

Structural transformations in heat-resistant protective coatings on nickel alloys  

Energy Technology Data Exchange (ETDEWEB)

In this work a comprehensive metallophysical study was carried out for two aluminosilicide slip coatings of the systems Al-Si and Al-Nb-Si and an electron-beam Co-Cr-Al-Y coating on alloy EP-539 (17...19% Cr, 4...6% Co, 2.5...4% W, 4.5...6.5% Mo, 2...3% Ti, 3...4% Al, 1.4...2% Nb, balance Ni) after high-temperature testing. The protective properties of the coatings were evaluated from the results of laboratory tests for heat resistance at 1000/sup 0/C in the combustion products of diesel fuel with added sulfur at 970, 1000, and 1060/sup 0/C for 100 h and after full-scale tests for 150, 250, 400, and 700 h. Metallographic, hardness, x-ray, and micro x-ray studies of the coating were carried out. Layer-by-layer phase composition and the lattice spacing of the main phases were determined. X-ray analysis was carried out in an a DRON-1 diffractometer in copper K/sub ..-->../-radiation, and x-ray microanalysis was carried out in a MS-46 Cameca ...

1987-09-01

359

Evaluation of impacts on wetlands: do NEPA analyses integrate wetland protection requirements  

Energy Technology Data Exchange (ETDEWEB)

The impacts of federal projects on wetlands should be included in documents prepared to comply with the National Environmental Policy Act (NEPA). NEPA assessments of impacts on wetlands are often related to requirements of other laws, regulations, and executive orders, such as permitting requirements under Section 404 of the Clean Water Act and those contained in Executive Order 11990, Protection of Wetlands. This paper reviews recent NEPA environmental impact statements that contained assessments of impacts on wetlands or that involved projects likely to affect wetlands. It covers documents prepared by several federal agencies, including the Army Corps of Engineers, Department of Energy, Federal Highway Administration, Soil Conservation Service, and Tennessee Valley Authority. The extent and depth of analyses of wetlands issues was found to be highly variable, both within and among agencies. Most analyses did not provide adequate geographical or ecological context ...

1991-01-01

360

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the ...

361

Measurements of transmittance of solar radiation through stearic acid: a latent heat storage material  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the experimental measurements of the transmittivity of commercial grade stearic acid. The effects of temperature and thickness on transmittance have been studied. The study indicates that the effect of temperature on the transmittance of stearic acid in the liquid phase is not significant. However, it is highly dependent on temperature during the solidification process. Because of its low thermal conductivity and high transmittivity, it can be used as a transparent insulating material. (Author)

1999-12-01

362

Gamma absorption determination of concentration in a three-component mixture  

International Nuclear Information System (INIS)

A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.

363

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

364

Gamma and X-ray shielding compositions utilizing bauxite - Red Mud regional research laboratory (CSIR), Bhopal, India  

International Nuclear Information System (INIS)

Available in abstract form only. Full text of publication follows: The application spectrum of X-ray and Gamma radiation is increasing exponentially in the area of diagnostic, nuclear medicine, food preservation, nuclear power plants and strategic utilities. To prevent the harmful effects of these radiations, shielding materials based on lead metal and its compounds are being used historically, which are toxic in nature. To protect environment it has become necessary to develop non-toxic lead free shielding materials. The use of titanium metal and its compounds as synthetic rock i.e. SYNROC are reported to be very effective non-toxic shielding materials for various applications. Red mud waste generated in aluminum producing industries possesses a unique mineralogical compositions containing fairly high quantity of titanium oxide and iron oxide useful for making non toxic shielding compositions and therefore red mud has been ...

2007-09-02

365

Apoptotic pathways as regulators of recombination  

International Nuclear Information System (INIS)

Apoptosis, or programmed cell death (PCD), is a fundamental process that protects organismal integrity. In earlier work, we demonstrated that over-expression of either of two anti-apoptotic members of the BCL-2 family (BCL-2 or BCL-X L could elevate the frequency of radiation-induced mutations at the autosomal TK1 locus in human TK6 lymphoblasts that express wild-type TP53. Ectopic expression of BCL-X L also elevated the frequencies of double-strand break-induced gene conversion. The purpose of this study is to determine if BCL-2 family proteins promote radiation mutagenesis indirectly through their suppression of PCD, or whether the 'pro-mutagenic' function of these proteins can be separated from their anti-apoptotic function. We developed stable transfectants of TK6 cells that express a mutated form of BCL-X L with a single amino acid substitution in the BH1 domain that is known to interfere with the ability to suppress ...

2003-08-17

366

Turn-key Raman lidar for profiling atmospheric water vapor, clouds, and aerosols at the US Southern Great Plains Climate Study Site  

Energy Technology Data Exchange (ETDEWEB)

There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for ...

1997-12-31

367

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

368

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and ...

1996-12-01

369

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially ...

370

Willingness to pay for energy-saving measures in residential buildings  

Energy Technology Data Exchange (ETDEWEB)

This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)

2008-03-15

371

The concept of power correction techniques and its use in the reactor regulation and protection systems in Indian PHWRs  

International Nuclear Information System (INIS)

Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)

2010-02-01

372

IC chip stress during plastic package molding  

Energy Technology Data Exchange (ETDEWEB)

Approximately 95% of the world`s integrated chips are packaged using a hot, high pressure transfer molding process. The stress created by the flow of silica powder loaded epoxy can displace the fine bonding wires and can even distort the metalization patterns under the protective chip passivation layer. In this study the authors developed a technique to measure the mechanical stress over the surface of an integrated circuit during the molding process. A CMOS test chip with 25 diffused resistor stress sensors was applied to a commercial lead frame. Both compression and shear stresses were measured at all 25 locations on the surface of the chip every 50 milliseconds during molding. These measurements have a fine time and stress resolution which should allow comparison with computer simulation of the molding process, thus allowing optimization of both the manufacturing process and mold geometry.

1998-02-01

373

Analysis of even harmonics generation in an isolated electric power system  

British Library Electronic Table of Contents (United Kingdom)

Harmonics bred from loads are mainly odd order because the current waveforms have half-wave symmetry. Since the even harmonics are negligibly small, they generally are not measured in electric power systems. However, even harmonics were measured at a 500/275/154 kV substation in Hokuriku Electric Power Company after a transmission line fault was corrected. The even harmonics caused malfunctions of protective digital relays because the relays used 4th harmonics at the input filter as the automatic supervisory signal. This paper describes mechanisms of generation of the even harmonics by comparing the measured waveforms with the ATP-EMTP simulation results. Analysis of these results has clearly shown that there are three different mechanisms of generation of even harmonics. The first mechani...

2009-01-01

374

The gamma radiation in improving the physical properties of wood-polymer composites  

International Nuclear Information System (INIS)

In the Peruvian natural forest there are several kind of woods, some of those are not of commercial interest, because have not resistance at termites and wet, are too soft, or can not be well finished, in the others. The present work is devoted to improvement of the physical properties of wood, such as hardness, traction, wet resistance, etc., by means of the generation of a composite wood-polymers cured by using gamma irradiation. The main objective is to establish the main parameters for the polymerization process (economic technical aspect) that decrease the amount of water absorption, in consequence the volumetric variation of Catahua, Mohena and Capirona woods. Gamma irradiation also provides good protection against the biological agents. In consequence, these woods increase its intrinsic and economic values. (author)

2006-07-01

375

Radiological considerations of the reactor cover gas processing system at the FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).

1986-09-24

376

Diagnostics hardening for harsh environment in Laser Megajoule (invited)  

International Nuclear Information System (INIS)

The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

2008-10-01

377

A.C.R.O. activity report 2006; A.C.R.O. rapport d'activite 2006  

Energy Technology Data Exchange (ETDEWEB)

This association participated in different working groups: North Cotentin radioecology group, groups of expertise on the uranium mines of Limousin, executive committee for the management of the post accidental phase of a nuclear accident or a radiological emergency situation, radioactive waste management, radiological surveillance of the territory, radiation protection mission by the Asn, radiological surveillance of the environment of the Chinon nuclear power plant, study of the presence of {sup 235}U around the site of Brennilis, study of the radioactive waste management at the Manche plant, radiological surveillance of the Cyceron cyclotron at Caen, Aurengo commission on the consequences in France of the Chernobylsk accident. Actions of information, regular publications, meeting with public are also a part of the work of this association. (N.C.)

2006-07-01

378

Assessment of the impact of the greenhouse gas emission and sink scenarios in Finland on radiative forcing and greenhouse effect  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been ...

1996-12-31

379

Microclimatic conditions at the external surface of building envelopes  

Energy Technology Data Exchange (ETDEWEB)

The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat ...

1998-12-31

380

Mixed waste landfill corrective measures study final report Sandia National Laboratories, Albuquerque, New Mexico.  

Energy Technology Data Exchange (ETDEWEB)

The Mixed Waste Landfill occupies 2.6 acres in the north-central portion of Technical Area 3 at Sandia National Laboratories, Albuquerque, New Mexico. The landfill accepted low-level radioactive and mixed waste from March 1959 to December 1988. This report represents the Corrective Measures Study that has been conducted for the Mixed Waste Landfill. The purpose of the study was to identify, develop, and evaluate corrective measures alternatives and recommend the corrective measure(s) to be taken at the site. Based upon detailed evaluation and risk assessment using guidance provided by the U.S. Environmental Protection Agency and the New Mexico Environment Department, the U.S. Department of Energy and Sandia National Laboratories recommend that a vegetative soil cover be deployed as the preferred corrective measure for the Mixed Waste Landfill. The cover would be of sufficient ...

2004-03-01

381

Fixed time and fixed point observation of environmental radioactivities in Tokyo  

Energy Technology Data Exchange (ETDEWEB)

A measurement of environmental radioactivity in Tokyo was started from 1974. We have been executing fixed time and fixed point observation since 1983 in Tokyo continuously. Measurement item is rain water, airborne dust, activated sludge at sewage treatment plants and external dose rate. Measurement data from 1983 to 1995 is reported in this paper. Moreover, we have been carried out the measurement of radon concentration in air from 1988 to 1991 in different types of residental buildings. The measurement results of rain water, airborne dust, external dose rate were approximately a background level respectively except for the Chernobyl nuclear power plant accident. Radionuclides used as radiopharmaceuticals were detected in the activated sludge at every sewage treatment plant but its concentration was lower than concentration limit in Japan. From a result of radon concentration ...

1997-03-01

382

On the genetic and somatic radiation doses in radiotherapy of inflammatory and degenerative diseases of bones, joints and soft parts  

International Nuclear Information System (INIS)

Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up ...

1983-01-01

383

Ionizing radiation alters beta-endorphin-like immunoreactivity in brain but not blood  

Energy Technology Data Exchange (ETDEWEB)

Previous behavioral and pharmacological studies have implicated endorphins in radiation-induced locomotor hyperactivity of the C57BL/6J mouse. However, the endogenous opiate(s) responsible for this behavioral change have not been identified. The present study measured beta-endorphin-like immunoreactivity (beta-END-LI) in brain, blood, and combined brain and pituitary samples from irradiated and sham-irradiated C57BL/6J mice. After radiation exposure, levels of beta-END-LI decreased significantly in the brain. A similar, but not statistically significant, decline was measured in combined brain and pituitary samples. Concentrations of blood beta-END-LI were not changed by irradiation. These radiogenic changes in beta-END-LI are in some ways similar to those observed after other stresses. However, radiation-induced locomotor hyperactivity may be mediated more by alterations of ...

1983-12-01

384

Behavioral effects of exposure to the TEMPO high-power microwave system. Interim report, January-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in ...

1988-03-01

385

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

Energy Technology Data Exchange (ETDEWEB)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18{sup 0}C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4{sup 0}C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. Irradiation damage of sarcoplasmic membranes appeared in the specimens ...

1990-01-01

386

Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)  

International Nuclear Information System (INIS)

The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18"0C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4"0C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. Irradiation damage of sarcoplasmic membranes appeared in the specimens irradiated at a ...

387

Estimation of cancer risks from radiotherapy of benign diseases  

Energy Technology Data Exchange (ETDEWEB)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...

2006-08-15

388

Estimation of cancer risks from radiotherapy of benign diseases  

International Nuclear Information System (INIS)

Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...

2006-08-01

389

Radiological assessment of terrestrial environment of facilities of G.I.P. CYCERON from Caen - year 2003; Bilan radiologique de l'environnement terrestre des installations du GIP CYCERON de Caen - annee 2003  

Energy Technology Data Exchange (ETDEWEB)

Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...

2004-07-01

390

Feasibility of optical sensing for robotics in highly radioactive environments  

International Nuclear Information System (INIS)

The application of robotics for repair, refurbishing or dismantling of nuclear installations implies eventually severe radiation resistance requirements on embarked components and subsystems. This is particularly critical when optical sensing is considered. Optoelectronic components and optical fibers are indeed quite sensitive to radiation, and without special design are rapidly out-of-operation in such an environment. This paper reports the results of a series of #gamma# irradiation experiments on such devices, and identify their behavior under radiation. Test results show that carefully selected optical fibers can keep their radiation induced attenuation lower than 0.3 dB/m even up to a total dose of 10 MGy. Temperature annealing can even lower this attenuation down to 0.1 dB/m. On the other hand, commercially available light emitting diodes and photodiodes present attenuations figures up to 15 dB, ...

1992-10-25

392

Radon measurements in the Catalagzi Thermal Power Plant, Turkey  

Energy Technology Data Exchange (ETDEWEB)

The Catalagzi Thermal Power Plant (CTPP) is located at nearly 13 km North-east of Zonguldak city, which is located at the West Black Sea coast in Turkey. The middling products with high ash content of bituminous coals are used in this plant. Seasonal radon concentration measurements have been carried out by using CR-39 plastic track detectors in and around the CTPP. The annual average radon concentration has been found to vary from a minimum of 39.8 {+-} 28.9 Bq m{sup -3}) in the ash area to a maximum of about to 75.0 {+-} 15.7 Bq m{sup -3} in the service building of the power plant. The annual average radon concentration in the dwellings of the thermal power plant colony of the plant is 71.0 {+-} 33.4 Bq m{sup -3}. The effective dose has been found to vary from 0.38 to 0.71 mSv y{sup -1} with a mean value of 0.56 mSv y{sup -1}, which is lower than the effective dose values 3-10 mSv given as the range of action levels recommended by International Commission on ...

2008-01-15

393

Radiographic in-situ measurements of intrinsic stresses between 750 C and 900 C. Optimisation of the measuring system; Roentgenographische In-situ-Messungen der Eigenspannungen zwischen 750 C und 900 C. Optimierung der Messeinrichtung  

Energy Technology Data Exchange (ETDEWEB)

One aspect of the research program SFB 570 'Distortion engineering' is the in situ X-Ray diffraction analysis of phases and residual stresses during complete heat treatment cycles. These investigations result in experimental evidence available for the extensive computations. The optimisation of the instrumentation will be reported. A surface decarburisation of samples made from the ball bearing steel 100Cr6 could be avoided for a temperature range from 800 to 900 C and a holding time of one hour by a combination of evacuate the furnace and using a certain nitrogen flow as protective gas. At lower temperatures small amounts of ferrite caused by an increased diffusion rate of carbon lead again to a surface decarburisation up to a depth of 2 {mu}m. It was proved that with an evacuation of the X-Ray beam path at constant power of the X-Ray source the intensity of diffraction lines could be increased by more than a factor of 4. The use of nitrogen as ...

2007-07-01

394

Tritium monitor with improved gamma-ray discrimination  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

1985-01-01

395

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

396

FFTF shield and gamma ray measurements  

Energy Technology Data Exchange (ETDEWEB)

Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.

1984-08-01

397

Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities  

Energy Technology Data Exchange (ETDEWEB)

The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.

1999-01-01

398

Si-JFET devices and related noise behavior under irradiation  

Energy Technology Data Exchange (ETDEWEB)

Monolithic N-channel junction field effect transistors (NJFETs) dc characteristics, small signal parameters and noise have been studied from 300 K down to cryogenic temperatures before and after irradiation with {sup 60}Co {gamma}-rays and fast neutrons (1 MeV). Radiation induced effects on dc parameters and noise are reviewed. Noise spectral density measurements performed at various temperatures have shown that the radiation induces a noise increase which is temperature and frequency dependent. (orig.). 14 refs.

1998-02-01

399

Radiolysis of neutron irradiated lithium solutions  

International Nuclear Information System (INIS)

In the Aqueous Self-Cooled Blanket (ASCB) concept, an aqueous "6Li solution in a metallic structure is used as a shielding-breeding blanket for fusion reactors. The experimental results of this study indicate that the radiolytic gas production in an ASCB will be proportional to the absorbed radiation energy. The observed radiation chemical yields allow the preliminary estimation of the radiolysis effects for a specific ASCB design. Contrary to the theoretical predictions, the use of hydrogen as a cover gas at up to 1 MPa had no measurable effect on the radiolytic gas production. Probably it will thus not be possible to suppress the radiolytic decomposition of a low-pressure ASCB by the addition of hydrogen. Catalytic recombination will be required. (orig.).

400

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

401

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

402

Photon angular distribution of radiative electron capture into the M shell of He-like uranium ions at 110-140 MeV/u  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the photon angular distribution of Radiative Electron Capture into the M shell have been performed with He-like uranium ions in the range 110-140 MeV/u. In addition, L REC was studied at a projectile energy of 140 MeV/u. In both cases, the experimental data show an asymmetry around 90 and agree well with a fully relativistic theory. (orig.) 15 refs.

1995-10-01

403

Parameterization of GCM subgrid nonprecipitating cumulus and stratocumulus clouds using stochastic/phenomenological methods. Annual technical progress report, 1 December 1992--30 November 1993  

Energy Technology Data Exchange (ETDEWEB)

This document is a progress report to the USDOE Atmospheric Radiation and Measurement Program (ARM). The overall project goal is to relate subgrid-cumulus-cloud formation, coverage, and population characteristics to statistical properties of surface-layer air, which in turn are modulated by heterogeneous land-usage within GCM-grid-box-size regions. The motivation is to improve the understanding and prediction of climate change by more accurately describing radiative and cloud processes.

1993-08-27

404

Palliation of radiation-related mucositis  

Energy Technology Data Exchange (ETDEWEB)

Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.

1990-01-01

405

Measurement of stress in materials using chromium K/sub. beta. / radiation  

Energy Technology Data Exchange (ETDEWEB)

Bragg peaks obtained in X-ray stress analysis studies are often asymmetric. The use of K/sub ..beta../ rather than K/sub ..cap alpha../ radiation simplifies the problem of peak location, as only one Bragg peak needs to be analysed. It is shown, however, that the common practice of fitting a parabola to the top 15% of the data in a Bragg peak in order to determine the peak position, when the fitted region is asymmetric, can lead to large errors in the calculated stress. Asymmetric pseudo-Lorentzian functions have been found to provide the most satisfactory fits.

1983-01-01

406

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

407

ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD  

Energy Technology Data Exchange (ETDEWEB)

A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.

1983-01-01

408

815nm radiation from germicidal lamps  

International Nuclear Information System (INIS)

An investigation of the intensity of electromagnetic radiation at a wavelength of 185nm emitted by a General Electric mercury discharge, germicidal lamp is described. From the measurement of the transmission of light as a function of wavelength from 185nm to 360nm, it was concluded that this type of germicidal lamp does not produce any biological or chemical effects through the 185nm line; the intensity of the 185nm line transmitted by the lamp was less than 0.1% of that for the 254nm line. Consequently, there was no discernable ozone production. (U.K.).

409

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

410

PROTECTIVE EFFECTS OF MIXTURE OF OXIMES IN NERVE ...  

Science.gov (United States)

... ATROPINE, HI-6 AND TOXOGONIN MIGHT OFFER THE SOLUTION FOR THE OVERALL PROTECTION AGAINST NERVE GAS POISONING HAS ...

1989-06-01

411

Identification of Protective Brucella Antigens and their ...  

Science.gov (United States)

... Considering these observations, it is most likely that Brucela proteins involved in protective immunity will preferentially stimulate INF-g producing T ...

1996-05-01

412

Use of the K88 antigen for in vivo bacterial competition with porcine strains of enteropathogenic Escherichia coli.  

Science.gov (United States)

Infant mice were used to measure the amount of fluid accumulation (enterosorption) in the intestinal tract after oral inoculation of a porcine strain of enteropathogenic Escherichia coli (K88-+, Ent-+). Significant reduction in the amount of fluid found in the intestinal tract was observed if the mice were first inoculated with a K88-possessing, non-enterotoxigenic strain of E. coli. The protection provided is thought to be due to specific competition for attachment sites on cells of the small intestine. PMID:1095492

1975-07-01

413

Response of track-etch dosemeters to environmental radon  

Energy Technology Data Exchange (ETDEWEB)

The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).

1988-01-01

414

Pitting corrosion of zirconium and hafnium  

Energy Technology Data Exchange (ETDEWEB)

The initiation and inhibition of pitting corrosion on zirconium and hafnium in aqueous solutions have been investigated by potentiodynamic, potentiostatic and galvanostatic measurements at 25/sup 0/C. Effects of Cl/sup -/, Br/sup -/and I/sup -/ have been examined over a range of salt concentrations and pH. All three halide ions cause pitting attack on the two metals, but this may be inhibited by other anions. The results show that hafnium is more easily protected against pitting than is zirconium. The data are treated by the Butler-Volmer equation to yield more information about the mechanisms of the pitting corrosion.

1988-02-01

415

Phytic acid doped nanoparticles for green anticorrosion coatings  

British Library Electronic Table of Contents (United Kingdom)

In this paper, an environmentally friendly metal corrosion inhibitor, phytic acid, was assembled into the walls of silica nanoparticles via layer-by-layer self-assembly technique (LbL) with poly(allylamine hydrochloride). Such functionalized nanoparticles were uniformly distributed into sol-gel films for metal anticorrosion. The films showed very pronounced and lasting protective efficiency in concentrated salt aqueous solutions as indicated by electrochemical impedance spectroscopy (EIS) measurement. These results may provide a new route for the preparation of environment-friendly anticorrosion coatings.

2010-01-01

416

Nuclear Forensics' role in analyzing nuclear trafficking activities  

International Nuclear Information System (INIS)

Nuclear forensics aims at identifying origin and intended use of nuclear material using information inherent to the nuclear material.The information gathered in nuclear forensics include isotopic composition, elemental composition, impurities and age of the material, macroscopic appearance and microstructure. The information so collected helps to solve criminal cases and put the individuals involved in nuclear trafficking in jails. The information also helps to improve safeguards and physical protection measures at place of theft or diversion to prevent future thefts or diversions.

2010-05-10

417

Influence of microalloying on the corrosion resistance of steel in saturated calcium hydroxide  

International Nuclear Information System (INIS)

The influence of microalloying vanadium or titanium on improving the corrosion resistance of mild steel in saturated calcium hydroxide solution was investigated. Potential-time, potentiodynamic polarization, and impedance measurement techniques were employed. The corrosion products have been examined by infrared and X-ray diffraction analysis and by scanning electron microscopy. It has been shown that the grain refining, due to microalloying, plays an important role in enhancing the corrosion resistance of steel. Scales of calcite and iron oxides on top of a protective oxide are formed on the investigated steels.

418

Effect of chloride concentration and pH on pitting corrosion of waste package container materials  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical cyclic potentiodynamic polarization experiments were performed on several candidate waste package container materials to evaluate their susceptibility to pitting corrosion at 90 degrees C in aqueous environments relevant to the potential underground high-level nuclear waste repository. Results indicate that of all the materials tested, Alloy C-22 and Ti Grade-12 exhibited the maximum corrosion resistance, showing no pitting or observable corrosion in any environment tested. Efforts were also made to study the effect of chloride ion concentration and pH on the measured corrosion potential (Ecorr), critical pitting and protection potential values.

1996-12-01

419

Development of flue gas carbon dioxide recovery technology  

Energy Technology Data Exchange (ETDEWEB)

As a counter measure to protect against global warming, the development of CO{sub 2} recovery technology from fossil fuel power plant flue gas has continued. MEA processes are widely used for CO{sub 2} recovery from combustion flue gas in average use etc. However, if we consider power plant scale CO{sub 2} recovery, the biggest theme is the reduction of energy needed to recover CO{sub 2}. The paper focuses on sterically hindered amines and a new absorber packing. Also optimum steam system analysis results are indicated. 1 ref., 16 figs., 3 tabs.

1994-12-31

420

Actions for the environment  

CERN Document Server

As an International Organization, one the most important issues that CERN has to respect and guarantee is the protection of the environment. Several of ST activities and operations have a direct impact on the environment: civil engineering works, electrical (transformers) and air-cooling operation, chemical products storage, various waste disposal etc.... Important measures, taken in the past, have to be kept and new ones should be applied in order to insure the conformity of the infrastructure with existing legislation, the correct operation of equipment and systems, the constant monitoring of the different situations and the traceability of the events. Moreover good management of the environment would bring large savings to CERN.

2003-01-01

421

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

422

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

423

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a ...

2008-01-01

424

Radiation processed composite materials of wood and elastic polyester resins  

International Nuclear Information System (INIS)

The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of wood composite ...

1982-09-19

425

Radiation hardening in neutron-irradiated polycrystalline copper: Barrier strength of defect clusters  

International Nuclear Information System (INIS)

Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).

1989-12-04

426

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

427

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

428

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

429

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

430

Heat loss from an open cavity  

Energy Technology Data Exchange (ETDEWEB)

Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating ...

1995-12-01

431

Electron scattering from atoms in the presence of a laser field. II  

Science.gov (United States)

In the first paper of this series a formal theory of atomic scattering of electrons in the presence of an intense electromagnetic field was given. Cross sections, near the forward direction, between atomic states (modified by the laser) were obtained. However, it was assumed that the atom could not emit spontaneous radiation. In this paper the effect of spontaneous radiation is included, and it is shown that in most cases the measured cross section will be a weighted average of the two different cross sections starting from the two different initial states which are those atomic states resonantly linked by the laser. The Born approximation for the scattering is obtained, and it is shown that for the simplest description of the spontaneous radiation field the effect of the laser on the cross sections is simply to multiply them by a factor which depends upon the laser detuning. (AIP)

1976-10-01

432

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

433

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

434

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

435
436

Operational experiences with cathodic protection of Statoil's main onshore pipelines: a description of the online monitoring systems  

Energy Technology Data Exchange (ETDEWEB)

Statoil is operating an increasing number of offshore and onshore pipelines in the North Sea area and elsewhere. Cathodic protection is a significant part of the corrosion management for these lines and we have collected a significant amount of experience with respect to design and operation of the systems. This paper deals with our comprehensive program for the onshore cathodic protection systems and the various challenges in different countries with respect to technical matters, such as operating conditions and different terrain. Generally, the systems are based on automatically controlled rectifier systems with a wide range of current drainage and very comprehensive monitoring of potentials and current flowing. The use of coupons, polarisation cells and buried reference cells are essential, as well as the use of intensive measurements along the route. The use of online monitoring of selected test posts and all rectifier ...

1999-07-01

437

Fine ceramics center; Fuain seramikkusu senta  

Energy Technology Data Exchange (ETDEWEB)

Fine ceramics center (JFCC) succeeded in the higher precision of thermal diffusivity measurement by the laser flash. This results are part of 'the research on thermophysical property measurement technique and standard substance of the functional material' by the intelligent establishing of a base promotion system of Science and Technology Agency. Cooperative research. thermal diffusivity with Natl. Res. Lab. of Metrology is one of the representative thermophysical property. The speed in which a heat transmits of the material is shown, and it is indispensable to the design of the high-temperature member subject. JFCC heralds the world as a standard substance for the thermal diffusivity measurement; 'TD-AL' using the alumina material is developed and is supplied in the spring in last year. Laser flash which uses laser beam for the heat source is general for the ...

1999-11-01

438

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, ...

2009-05-26

439

Remote Sensing and In-Situ Observations of Arctic Mixed-Phase and Cirrus Clouds Acquired During Mixed-Phase Arctic Cloud Experiment: Atmospheric Radiation Measurement Uninhabited Aerospace Vehicle Participation  

Energy Technology Data Exchange (ETDEWEB)

The Atmospheric Radiation Monitor (ARM) uninhabited aerospace vehicle (UAV) program aims to develop measurement techniques and instruments suitable for a new class of high altitude, long endurance UAVs while supporting the climate community with valuable data sets. Using the Scaled Composites Proteus aircraft, ARM UAV participated in Mixed-Phase Arctic Cloud Experiment (M-PACE), obtaining unique data to help understand the interaction of clouds with solar and infrared radiation. Many measurements obtained using the Proteus were coincident with in-situ observations made by the UND Citation. Data from M-PACE are needed to understand interactions between clouds, the atmosphere and ocean in the Arctic, critical interactions given large-scale models suggest enhanced warming compared to lower latitudes is occurring.

2005-03-18

440

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

441

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the ...

1991-06-01

442

Joint Thesaurus. Part I (A-L) + Part II (M-Z)  

International Nuclear Information System (INIS)

This is the 1st revision of the INIS/ETDE Joint Thesaurus. It contains 20 953 valid descriptors and 8 600 forbidden terms. It was last updated in December 2003. The Joint Thesaurus contains the controlled terminology for indexing all information within the subject scope of both INIS (International Nuclear Information System) and ETDE (Energy Technology Data Exchange) information systems. The terminology is intended for use in subject description for input or retrieval of information in those systems. The thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language It is also a controlled and dynamic vocabulary of semantically and generically related terms which covers a specific domain of knowledge. The domain of knowledge covered by this Thesaurus includes physics (in particular, plasma physics, atomic and molecular physics, and especially nuclear and high-energy physics), chemistry, ...

1998-05-01

443

Biological Effects after Prenatal Irradiation  

International Nuclear Information System (INIS)

A Task Group of the International Commission on Radiological Protection (ICRP) has finished a report Biological Effects after Prenatal Irradiation (Embryo and Fetus) which has been approved by the Main Commission and Will be Published. Some new important scientific data shall be discussed in this contribution. During the preimplantation period lethality of the mammalian embryo is the dominating radiation effect. However, in mouse strains with genetic predispositions it has been shown that also malformations can be caused. This effect is genetically determined and its mechanisms is different from the induction of malformations during major organogenesis. Radiation exposures during this prenatal period leads ato an increase of genomic instability of cells in the normal appearing fetuses. These radiation effects can be transmitted to the next generation. A renewed analysis of individuals with severe mental ...

444

Geology, public policy, and the North Carolina low level radioactive waste (LLRW) disposal facility project  

Energy Technology Data Exchange (ETDEWEB)

North Carolina is in the process of siting a LLRW disposal facility as the next host state for the Southwest Compact. After two years of site characterization studies at two technically challenging sites, the LLRW Management Authority (the Authority), will submit a license application for the preferred site. One potential site is in unconsolidated Tertiary and Cretaceous deposits of the inner Coastal Plain, the other in fractured sedimentary rocks of the Triassic Deep River Basin. Involved since 1986, the North Carolina Geological Survey (NCGS) provides technical advice to the Division of radiation Protection, the state regulatory agency authorized to approve or deny a license. With the multi-million dollar project behind schedule, and millions of dollars over budget, in February 1992 the Southeast Compact Commission established three project milestones (1) submit license application by December 31, 1993; (2) approve license by March 15, 1994; ...

1994-03-01

445

Differential effects of chronic ingestion of tritiated water on prenatal brain development  

International Nuclear Information System (INIS)

Female rats were given tritiated drinking water (3 microCi/ml) from 30 days before mating up to and throughout pregnancy. At this low dose, the course and the outcome of pregnancy were normal. The differences between newborn body and cerebral weights of the treated rats and those of control animals were on the borderline of significance. In contrast, cerebral DNA and cerebral protein were highly significantly lower. In 30-35% of the treated population the DNA and protein values were more than 2 standard deviations (SD) below the mean values for the control population. Thus the number of the progeny of the mothers exposed to tritiated water that were considered to have outstandingly low levels of DNA and protein was 14-17 times greater than in the control group. The irradiated population also had 3-5% of severely affected individuals with cerebral DNA and protein values more than 2 SD below the mean of the experimental population. However, even in this irradiated population, a certain ...

446

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

447

The Argonne boundary layer experiments facility : using minisodars to complement a wind profiler network.  

Energy Technology Data Exchange (ETDEWEB)

The Argonne Boundary Layer Experiments (ABLE) facility, located in south central Kansas, east of Wichita, is devoted primarily to investigations of and within the planetary boundary layer (PBL), including the dynamics of the mixed layer during both day and night; effects of varying land use and land form; the interactive role of precipitation, runoff, and soil moisture; storm development; and energy budgets on scales of 10 to 100 km. Located entirely within the Walnut River watershed, ABLE provides intense measurements within the northeast quadrant (Fig. 1) of the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) of the Atmospheric Radiation Measurement (ARM) Program (Stokes and Schwarz, 1994). By combining the continuous measurements of ABLE with ancillary continuous measurements of, for example, the ARM and the Global Energy Water cycle Experiment ...

1998-06-05

448

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to ...

2003-11-01

449

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

450

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is ...

1981-01-01

451

Measurements to be taken after a nuclear accident in order to limit the uptake of radionuclides from the soil by nutrition crops  

International Nuclear Information System (INIS)

By the department Radio-ecology of the Laboratory for Radiation Research, in the period 1981 up to 1989 inclusive, the transfer has been studied, from soil to plant, of a number of important activation and fission products, originating in the nuclear-power production in nuclear power plants. The purpose of this study was twofold: on the one side the quantification of this transfer for various agrarian systems and on the other side to find out in how far, after an accidental contamination, certain agriculture activities can influence essentially the transfer and subsequently the radiation burden for the population. Emphasis lay, the last years, in particular upon this second aspect. The results of this study form essential basic data for diffusion models for radioactive materials which, in turn, are important in estimating the effects of measures. (author). 6 refs.; 4 figs.

452

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

453

Photochemical assessment monitoring: Overview and current status  

Energy Technology Data Exchange (ETDEWEB)

The Clean Air Act Amendments of 1990, established requirements for the Environmental Protection Agency (EPA) to develop rules for the establishment of enhanced ozone monitoring networks or Photochemical Assessment Monitoring Stations (PAMS) in ozone nonattainment areas designated as serious, severe, and extreme. The subsequent rules require these stations to collect ambient air measurements for a target list of volatile organic compounds including several carbonyls, oxides of nitrogen, ozone, and meteorological measurements, both surface and upper air. Twenty-two areas in the US are obligated to install and operate PAMS stations to aid in the identification, development, and implementation of effective ozone control strategies. This paper will examine the specific requirements of the PAMS rules and will provide information regarding the current status of the networks and overall implementation issues.

1994-12-31

454

Measurements of environmental policy for air pollution abatement. Umweltpolitische Massnahmen zur Luftreinhaltung; Kosten-Nutzen-Analyse  

Energy Technology Data Exchange (ETDEWEB)

The first part of the study goes into the determination of efficient strategies for the reduction of air pollutants. The developed method is not only derived theoretically but is tested with the concrete example of emissions sources of a German state. The second part goes into the question what the government can do in order to attain that air pollution abatement measures recognized as being efficient will be put into practice. As market economy mechanisms have advantages over central state planning in the allocation of economic resources the question arises if not also for environmental protection market economy tools may contribute to an improvement of the efficiency of air pollution abatement. Therefore the suitability of different tools of environmental policy for the realization of efficient air pollution abatement is investigated and evaluated. This is again not done abstractly but with existing emission sources. (orig./HSCH). 32 figs., ...

1993-01-01

455

Estimation of throughfall erosivity in a highly diverse forest ecosystem using sand-filled splash cups  

British Library Electronic Table of Contents (United Kingdom)

Sand-filled splash cups were used to study the erosive power of rainfall and throughfall in the humid subtropics of Southeast China. The splash cup measurements yielded precise and reproducible results under both open field conditions and forest vegetation. The splash cups were exposed to specific forest stands of different ages and to selected species (Schima superba, Castanopsis eyrei, Daphniphyllum oldhamii, Lithocarpus glaber) in the Gutianshan (???) National Nature Reserve (GNNR). The results of the measurements under forest vegetation show that the erosive power of throughfall drops to be 2.59 times higher compared to the open field. This accentuates the importance of shrub, herb and litter layers in forest ecosystems to protect the soil against erosion. Coalescing drops from leaves ...

2010-01-01

456

Electrical installations in locations with explosion hazards  

Energy Technology Data Exchange (ETDEWEB)

The optimization of the safety characteristics of electrical installations in industrial plants with explosion or fire hazards can be obtained only through a careful interdisciplinary study and analysis carried out at the onset of the plant project design phase. The least complex and costly and safest solutions are those which are born from plant designs which take into account the typology of the industrial process or technology, or which incorporate pollution abatement measures and adequate safety measures for the electrical installations. This paper provides examples to illustrate how the global plant economy is fundamentally dependant upon a multi-disciplinary initial effort in design analyses. Comments are made relevant to the adequacy of the safety requirements established by existing and planned Italian norms in dealing with safety and fire protection for high-tech industrial plant electrical installations.

1987-11-01

457

Performance of SPNDs used in control and safety systems  

International Nuclear Information System (INIS)

Large sized reactor such as 540 MWe Pressurised Heavy Water Reactor (PHWR) requires continuous in core monitoring of local flux in order to provide effective control and protection. About 198 self powered neutron detectors (SPNDs) of the straight individually replaceable type are distributed in the reactor core. For purposes of reactor regulation, 42 prompt responding cobalt SPNDs called zone control detectors (ZCDs) are housed in vertical flux units (VFUs) and these are uniformly distributed in 14 power zones. The in core detectors used for spatial control by ZCCs do not accurately represent average zone power as they sense the flux over a small volume. Flux mapping system (FMS) comprising of 102 vanadium SPNDs in 26 VFUs, provide accurate measure of neutron flux, even though they have slow response to change in neutron flux levels. For reactor protection system-1 (RPS-1), 36 cobalt SPNDs are placed in VFUs and become part ...

2006-11-13

458

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...

459

[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].  

Science.gov (United States)

Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295

1986-01-01

460

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

461

Human climatic comfort within enclosing walls with varying strengths of infrared radiation reflection  

Energy Technology Data Exchange (ETDEWEB)

An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% saving in heating ...

1985-06-01

462

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal ...

1981-10-01

463

Daytime Raman lidar measurements of water vapor during the ARM 1997 water vapor intensive observation period  

Energy Technology Data Exchange (ETDEWEB)

Because of the importance of water vapor, the ARM program initiated a series of three intensive operating periods (IOPs) at its CART (Cloud And Radiation Testbed) site. The goal of these IOPs is to improve and validate the state-of-the-art capabilities in measuring water vapor. To date, two of the planned three IOPs have occurred: the first was in September of 1996, with an emphasis on the lowest kilometer, while the second was conducted from September--October 1997 with a focus on both the upper troposphere and lowest kilometer. These IOPs provided an excellent opportunity to compare measurements from other systems with those made by the CART Raman lidar. This paper addresses primarily the daytime water vapor measurements made by the lidar system during the second of these IOPs.

1998-04-01

464

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

465

A high sensitivity two-color interferometer for pulsed power plasmas  

International Nuclear Information System (INIS)

A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are ...

466

The radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature  

International Nuclear Information System (INIS)

Generally, neutron, ion and electron Irradiations cause a substantial amount of hardening and significantly alter the deformation behavior of metals and alloys at relatively low irradiation temperatures. A radiation hardening is caused by the formation of microstructural defects such as dislocation loops, voids and precipitates under irradiation. Therefore, it is important to have a better knowledge of the irradiation induced microstructural defects under irradiation condition. As a part of the National mid- and long-term atomic energy R and D program, we are dealing with the radiation hardening behavior in Fe-Cr binary alloy. Fe-Cr binary alloy is a base alloy of Ferritic/Martensitic steel(F/M steel) planning to use for the Gen IV nuclear system. In this work, we investigated the radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature using nano-indentation ...

2009-05-01

467

Study on laminar burning velocity of premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames; CH{sub 4}/O{sub 2}/CO{sub 2} yokongo kaen no soryu nensho sokudo ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

Experimental and numerical investigations were performed for the laminar burning velocity and the flame structure of laminar premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames. Measurements of the laminar burning velocity were conducted by using a flame cone angle method for a circular nozzle burner. Numerical simulation was performed using one-dimensional plane flame code including radiation heat loss with an optically thin model. It was shown that the laminar burning velocity decrease with CO{sub 2} addition even though the adiabatic flame temperature is the same as that for CH{sub 4}/Air flames. The radiation heat loss is significant for the CH{sub 4}/O{sub 2}/CO{sub 2}, flames, and the flame temperature and laminar burning velocity decreases when the radiation heat loss is considered. Effects of thermal properties, radiation, and chemical reaction on the determination of the laminar ...

1999-07-25

468

Microwave radiation effects on the thermally driven oxidase of erythrocytes  

Energy Technology Data Exchange (ETDEWEB)

Sheep red blood cells (SRBCs) were labelled with a concanavalin A-luminol-bovine serum albumin conjugate specific for the transmembrane anion transport protein (Band 3) and exposed to 2450-MHz continuous-wave microwave radiation at an average specific absorption rate of 91W/kg for 10 min. The temperature was held constant at 25, 37, 40, 42, or 45C with an airflow heat-exchange system. Following exposure to microwave or air heating, the decrease in residual base-activated chemiluminescence (CL) of the SRBCs was measured as an indication of infield oxidase activity. Air heating resulted in a significant decrease in residual CL at temperatures above 37C (74% decrease at 45C). Microwave radiation inhibited the decline in residual CL above 37C. At 45C the inhibition was 40%. The results suggest microwave radiation either reversibly altered the thermodynamics of oxygen binding to haemoglobin or failed to ...

1986-01-01

469

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging. 2  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from simultaneous aging tests, while the lifetime of other ...

1994-01-01

470

Gene expression analysis after low dose ionising radiation exposure of the developing organism  

International Nuclear Information System (INIS)

Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two main stages of ...

2007-09-01

471

Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data  

Science.gov (United States)

The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on several hours (2-10) an appropriate maximum of ...

2010-01-01

472

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the ...

1979-01-01

473

Electric field measurement on time domain generated by corona on insulators on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done ...

1996-12-31

474

Toxicological benchmarks for screening contaminants of potential concern for effects on freshwater biota  

International Nuclear Information System (INIS)

An important early step in the assessment of ecological risks at contaminated sites is the screening of chemicals detected on the site to identify those that constitute a potential risk. Part of this screening process is the comparison of measured ambient concentrations to concentrations that are believed to be nonhazardous, termed benchmarks. This article discusses 13 methods by which benchmarks may be derived for aquatic biota and presents benchmarks for 105 chemicals. It then compares them with respect to their sensitivity, availability, magnitude relative to background concentrations, and conceptual bases. This compilation is limited to chemicals that have been detected on the US Department of Energy's Oak Ridge Reservation (ORR) and to benchmarks derived from studies of toxic effects on freshwater organisms. The list of chemicals includes 45 metals and 56 industrial organic chemicals but only four pesticides. Although some individual values can be shown to be ...

475

Fifteenmile Basin habitat enhancement project : annual report FY 1990.; ANNUAL  

International Nuclear Information System (INIS)

The goal of the Fifteenmile Creek Habitat Improvement project is to improve wild winter steelhead habitat in the Fifteenmile Creek Basin. This goal was addressed under the Columbia River Basin Fish and Wildlife Program, Measure 703 (c) (1) - Action Item 4.2. Construction of fish habitat structures was completed on approximately 3.5 miles of Eightmile Creek and on approximately 8.5 miles of Fifteenmile Creek. A total of 15,435 yds of rock was placed to improve rearing and spawning habitat, and to improve water quality and reduce siltation. Riparian protection fencing was completed on 1.8 miles of Dry Creek, approximately 1.75 miles on Eightmile Creek, and 4.75 miles on Fifteenmile Creek. Approximately 10 miles of stream will receive protection from the 8 miles of new fencing installed and 6.5 miles of abandoned fence repaired. Irrigation withdrawal screens were installed at six irrigation pump withdrawals. These screens ...

476

Dynamic security assessment in electric power systems  

Energy Technology Data Exchange (ETDEWEB)

A new approach to dynamic security assessment in electric power systems is proposed. A power system is modeled as a dynamical system with random variable structure. Structural variations are caused by primary and secondary events. Primary events are state-independent disturbances representing line and unit faults and load changes and are modeled by random jump processes. Secondary events that represent forced line and unit outages and load sheddings are modeled through an aggregate representation of the protection system as random processes whose change in time corresponds to the crossing of switching surfaces by the state process. These switching surfaces are defined by the setting of the protective relays. Commensurate with this model a three-state decomposition of the operating conditions into normal, emergency, and partial load operating states is suggested. Transitions between these states are described in terms of set-valued mappings in ...

1983-01-01

477

Traces of evidence. Nuclear forensics and illicit trafficking  

International Nuclear Information System (INIS)

An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other ...

2003-06-01

478

Alteration of the enterohepatic recirculation of bile acids in rats after exposure to ionizing radiation  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport ...

2004-02-01

479

Summary of Uranium City, Saskatchewan remedial measures for radiation reduction with special attention to vent fan theory  

International Nuclear Information System (INIS)

Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.

1980-03-12

480

Rocket borne solar eclipse experiment to measure the temperature structure of the solar corona via lyman-. cap alpha. line profile observations  

Energy Technology Data Exchange (ETDEWEB)

A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.

1981-01-01

481

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.

1991-01-01

482

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.

1991-12-31

483

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

484

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

485

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

486

The PAMELA space mission  

Energy Technology Data Exchange (ETDEWEB)

The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.

2009-03-15

487

Tests for mutagencity of free radicals formed in irradiated sugars and amino acids  

International Nuclear Information System (INIS)

Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.

1977-05-01

488

Strengh functions of strontium 88 obtained from the analysis of the (#gamma#,n) reaction near the threshold  

International Nuclear Information System (INIS)

The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.

1987-09-14

489

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

490

Quantum Cloning for Absolute Radiometry  

International Nuclear Information System (INIS)

In the quantum regime information can be copied with only a finite fidelity. This fidelity gradually increases to 1 as the system becomes classical. In this Letter we show how this fact can be used to directly measure the amount of radiated power. We demonstrate how these principles can be used to build a practical primary standard.

2010-08-20

491

Pyrheliometry  

Energy Technology Data Exchange (ETDEWEB)

Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.

1981-01-01

492

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

493

Extraction of Kaon Formfactors from K->mu nu gamma Decay at ISTRA+ Setup  

CERN Document Server

The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).

2010-01-01

494

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

Energy Technology Data Exchange (ETDEWEB)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.

1980-10-01

495

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

International Nuclear Information System (INIS)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).

1980-01-01

496

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

497

The main activities and scientific collaboration possibilities at Ankara Nuclear research and training center  

International Nuclear Information System (INIS)

Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of ...

2004-10-01

498

Efficient natural defense mechanisms against Listeria monocytogenes in T and B cell-deficient allogeneic bone marrow radiation chimeras. Preactivated macrophages are the main effector cells in an early phase after bone marrow transfer  

International Nuclear Information System (INIS)

Radiation chimeras in the early phase after bone marrow transplantation are a good model to study the efficiency of the body's nonspecific defense system represented by macrophages (M phi), polymorphonuclear cells (PMN), and NK cells. These cell types are present in large numbers in spleen and liver at that time, whereas the specific immune system represented by T and B cells is functionally deficient. We previously reported enhanced activities in vitro of M phi (and PMN) from recipient animals in an early phase after allogeneic bone marrow transfer. We here demonstrate that these activities result in enhanced spontaneous resistance against Listeria monocytogenes in vivo: CFU of L. monocytogenes in spleen and liver 48 h after infection were about 1 or 2 to 4 log steps less than in untreated control mice of donor or host haplotype. This enhanced resistance decreased over the 4-mo period after marrow transfer. Preactivated M phi were identified as the most important ...

499

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray ...