WorldWideScience
1

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

2

Accidents - Chernobyl accident; Accidents - accident de Tchernobyl  

Energy Technology Data Exchange (ETDEWEB)

This file is devoted to the Chernobyl accident. It is divided in four parts. The first part concerns the accident itself and its technical management. The second part is relative to the radiation doses and the different contaminations. The third part reports the sanitary effects, the determinists ones and the stochastic ones. The fourth and last part relates the consequences for the other European countries with the case of France. Through the different parts a point is tackled with the measures taken after the accident by the other countries to manage an accident, the cooperation between the different countries and the groups of research and studies about the reactors safety, and also with the international medical cooperation, specially for the children, everything in relation with the Chernobyl accident. (N.C.)

2004-07-01

3

About tachyons  

International Nuclear Information System (INIS)

... Part A: The electromagnetic radiation of a charged tachyon. Part B: Some

4

Structural and functional aspects of radiation adrenalopathy  

Energy Technology Data Exchange (ETDEWEB)

As part of a combined study of the responses of the mouse adrenal gland and kidney to X-irradiation, the weight of adrenal glands, the relative volumes of the cortex and medulla and the aldosterone output were measured at predetermined times after irradiation of the left organs only.

1986-01-01

5

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

6

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration ...

2008-11-19

7

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a ...

1998-02-01

8

Radiation treatment of crude drugs. Development of suitable methods of detection. Strahlenbehandlung von Arzneidrogen. Entwicklung geeigneter Nachweismethoden  

Energy Technology Data Exchange (ETDEWEB)

It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).

1992-09-01

9

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan ...

2007-07-01

10

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan ...

2007-05-10

12

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

13

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

14

On the genetic and somatic radiation doses in radiotherapy of inflammatory and degenerative diseases of bones, joints and soft parts  

International Nuclear Information System (INIS)

Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up ...

1983-01-01

15

Electroluminescence Study of Green Be-Contained II-VI ...  

Science.gov (United States)

... laser structure. However, still the greater part (60%) of emitted photons is a result of a spontaneous radiation process. In ...

2000-06-23

17

FY1999 Meeting of The Society of Heating, Air-Conditioning and Sanitary Engineering of Japan. Thermal simulation I; 1999 nendo gakujutsu koenkai gaiyo. Onnetsu simulation 1  

Energy Technology Data Exchange (ETDEWEB)

E-35 reported the specific air flow analysis program using a CFSV model (including a human body model) to develop a high-accuracy evaluation simulator for heterogeneous thermal environment based on human thermal physiological conditions. E-36 reported development of the radiation heat transfer analysis module by using a numerical integral method to calculate shape factors. Radiation heat transfer characteristics every body part were clarified quantitatively by this module. E-37 reported the results on continuous measurement of physiological conditions and thermal environment factors every monitor under controlled indoor thermal environment, to collect measurement data necessary for improving the accuracy of a prediction program for human body temperatures. E-38 reported the study result on physiological reaction and subjective evaluation through an examinee experiment in a blood ...

1999-12-05

18

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

19

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

20

Estimating extreme values of thermal gradients in concrete structures  

British Library Electronic Table of Contents (United Kingdom)

Temperature variations due to climate changes are a major cause of movements in a concrete structure, both in the longitudinal and transversal directions and between different parts of the structure. If these movements are restrained, stresses will be induced which may contribute to cracking. The movements are caused by complex interactions of several factors such as solar radiation, air temperature, long-wave heat radiation and wind speed. To predict the varying thermal conditions in a concrete structure a finite element model has been used. A validation of the model has been performed using field measurements in a concrete slab together with climate data from the Swedish Meteorological and Hydrological Institute to be able to use the model for simulations over long time periods and for s...

2011-01-01

21

Study of the physical and mechanical changes in packaging materials used in radiation processing - measuring methods of physical and mechanical properties  

International Nuclear Information System (INIS)

The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline ...

22

The radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature  

International Nuclear Information System (INIS)

Generally, neutron, ion and electron Irradiations cause a substantial amount of hardening and significantly alter the deformation behavior of metals and alloys at relatively low irradiation temperatures. A radiation hardening is caused by the formation of microstructural defects such as dislocation loops, voids and precipitates under irradiation. Therefore, it is important to have a better knowledge of the irradiation induced microstructural defects under irradiation condition. As a part of the National mid- and long-term atomic energy R and D program, we are dealing with the radiation hardening behavior in Fe-Cr binary alloy. Fe-Cr binary alloy is a base alloy of Ferritic/Martensitic steel(F/M steel) planning to use for the Gen IV nuclear system. In this work, we investigated the radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature using ...

2009-05-01

23

Electric field measurement on time domain generated by corona on insulators on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several ...

1996-12-31

24

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

25

Fine ceramics center; Fuain seramikkusu senta  

Energy Technology Data Exchange (ETDEWEB)

Fine ceramics center (JFCC) succeeded in the higher precision of thermal diffusivity measurement by the laser flash. This results are part of 'the research on thermophysical property measurement technique and standard substance of the functional material' by the intelligent establishing of a base promotion system of Science and Technology Agency. Cooperative research. thermal diffusivity with Natl. Res. Lab. of Metrology is one of the representative thermophysical property. The speed in which a heat transmits of the material is shown, and it is indispensable to the design of the high-temperature member subject. JFCC heralds the world as a standard substance for the thermal diffusivity measurement; 'TD-AL' using the alumina material is developed and is supplied in the spring in last year. Laser flash which uses laser beam for the heat source is general for the ...

1999-11-01

26

A.C.R.O. activity report 1999; A.C.R.O. rapport d'activite scientifique 1999  

Energy Technology Data Exchange (ETDEWEB)

The work of this association is cut according to 6 axes. Three publications: radiological quality of marine and continental waters of the Normandy coast (synthesis 1997 and 1998); preliminary study of the iodine 129 distribution in the environment of the reprocessing plant of La Hague with terrestrial moss (Homalotecium sericeum); radiological surveillance of the aquatic environment of the nuclear facilities on the area of La Hague (1997 and 1998). The second axis concerns the radiation protection with a campaign of radon measures in a school of the Vire rural district (june 1999). The third part is devoted to the radioecology with the surveillance of radioactivity in the aquatic continental environment of nuclear facilities and the radioecological surveillance (1999) of the building site of Cogema la Hague in the area of tidal range of the Moulinets cove. The fourth part concerns the radioactive waste ...

1999-07-01

27

Application of multi-stage, multi-disk type downhole seismic source; Tadanshiki taso enbangata koseinai shingen no tekiyosei  

Energy Technology Data Exchange (ETDEWEB)

A multi-stage, multi-disk type seismic source was developed as a downhole seismic source. The seismic source is an improved version of the downhole seismic source of a system in which an elastic wave is generated by a weight accelerated by restitutive force of a spring striking the upper part of a laminated structure consisted of metal disks and elastic bodies installed in water in a well. Enhancing the vibration exciting efficiency requires impedance radiated from the disks to be increased. The multi-disk structure was adopted because of restrictions on the disk area under the limiting condition of being inside the well. Further limitation has still existed, which led to finally structuring the multi-disk type to a multi-stage construction to increase the radiated impedance. In order to increase average velocity on the radiation surface, mass relationship between the hammer and the anvil was sought so ...

1997-05-27

28

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...

2010-01-15

29

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

International Nuclear Information System (INIS)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal ...

2010-01-01

30

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, ...

1999-07-01

31

Estimation of dose in irradiated chicken bone by ESR method  

Energy Technology Data Exchange (ETDEWEB)

The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was {gamma}-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated doses of chicken bones initially irradiated at 3.0kGy, 1.0kGy, ...

1998-03-01

32

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and ...

1993-01-01

33

Tumorigenic and tumoricidal actions of ionizing radiations  

Energy Technology Data Exchange (ETDEWEB)

The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.

1983-01-01

34

Experts' discussion on the possibility of quantification of the radiation hazard  

International Nuclear Information System (INIS)

Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).

1978-01-01

35

VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...  

Science.gov (United States)

Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...

36

Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest ...

1990-01-01

37

A detailed analysis of the properties of radiolyzed proteinaceous amino acids  

International Nuclear Information System (INIS)

The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. ...

2011-03-01

38

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

39

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

40

EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion interactions studies, ...

1996-10-01

41

Monte Carlo-based investigation of effect of inhomogeneity in brachytherapy dose calculation - Part I  

International Nuclear Information System (INIS)

Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium consisting of bone, soft tissue, lung, air ...

2009-04-01

42

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the ...

2009-03-01

43

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the ...

2007-06-15

44

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

45

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...

1983-06-01

46

Using ICCD as a fast optical switch to measure harmonic super-radiation from an optical klystron in a storage ring  

International Nuclear Information System (INIS)

An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate

2001-07-01

47

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and ...

2008-05-01

48

Calibration and analysis of soil carbon efflux estimates with closed chambers at Forsmark and Laxemar  

International Nuclear Information System (INIS)

The Forsmark and the Laxemar investigation areas are examined by the Swedish Nuclear Fuel and Waste Management Co. for a possible construction of a deep repository for nuclear waste. In the case of a future leakage of waste, the radioactive isotopes could end up in the ecosystems above the repository. The fate of the radionuclides and their possible radiological impacts are then highly determined by ecosystem carbon cycling. An important part of the carbon cycling is the soil carbon effluxes, and in the investigation areas soil carbon effluxes have been examined with the closed chamber technique. This paper is divided into two parts. Firstly, there were problems with the equipment measuring the soil carbon dioxide efflux, and the first part is a description of the problem, how it was corrected and its possible causes. The second part is a manual in how to analyse data and calculate ...

2007-01-01

49

The behaviour of stratospheric and upper tropospheric ozone in high and mid latitudes; the role of ozone as a climate gas  

Energy Technology Data Exchange (ETDEWEB)

During the past few years, the dual role that ozone plays in climate change has been becoming increasingly obvious. First, continuous thinning of the ozone layer has been evident, even in the high and middle latitudes in the northern hemisphere. Secondly, ozone is also a greenhouse gas, affecting radiative transfer. Increases in tropospheric ozone have a positive forcing, whereas decreases in stratospheric ozone cause a negative forcing. During the last six years, measurements on total ozone and the vertical distribution of ozone have been performed at the Sodankylae Observatory. At Jokioinen Observatory, measurements on total ozone have been performed since 1990 and measurements on the vertical distribution of ozone since 1993. The overall project has focused on extending the national data series on total ozone and the vertical distribution of ozone. At the same time, the study has contributed to the ...

1996-12-31

50

Applications or radiation polymerization hardening to composites  

International Nuclear Information System (INIS)

Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at ...

1976-01-01

51

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

52

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

53

Noncommissioned Officer Education System (NCOES) ...  

Science.gov (United States)

... While some measures were suggested as counseling tools to guide and influence ... it be awarded as part of the NCO Evaluation Report (NCOER). ...

2008-11-01

54

Radiation epidemiological analysis of late effects of population exposure at northern part of east ural radioactive trace  

Energy Technology Data Exchange (ETDEWEB)

Population residing in the northern part of the Chelyabinsk oblast and the south eastern part of the Sverdlovsk oblast of Russia affected to accidental exposure since 1957. The territory (East Ural Radioactive Trace - EURT) was contaminated after explosion of container with highly radioactive wastes at the Mayak Production Association. Studies of health effects of exposure in the southern, head part of EURT are conducted in the Ural Research and Practical Center of Radiation Medicine (U.R.P.R.M.). In the 1990's U.R.P.C.R.M. formed a cohort of EURT within Chelyabinsk oblast (14,500 cases and 19,400 external controls). The cohort was followed in 1957-1987 and the results of the study are discussed by Crestinina et al. First results of study on exposure late health effects among rural population in the northern part of the EURT are presented in this paper. Firstly, or the ...

2006-07-01

56

Spontaneous radiation-induced alignment of dipole moments of atoms moving in a medium  

International Nuclear Information System (INIS)

The effect on an oscillator moving in a medium produced by that part of the radiative force which does not perform work but creates and angular moment is considered. It is shown that the radiative torque turns the dipole toward the axis along which it is moving. Near the axis of motion the dipole executes small oscilltions. The frequency of the oscillations is determined. This effect leads to spontaneous alignment of the dipole moments on moving through the medium. The feasibility of observing the effect experimentally is discussed.

1986-01-01

57

Ionising radiation. Part 2  

Energy Technology Data Exchange (ETDEWEB)

A brief tutorial on the health effects of ionising radiation is presented. The distinction between somatic and genetic health effects is explained. The two types of somatic health effects, i.e., acute and chronic effects, are discussed, as well as the concepts of ''deterministic'' and ''stochastic'' (also called ''probabilistic'') health effects. The possibility of cancer caused by DNA damage is discussed. The document ends with the definition of some key radiation terms.

2000-11-01

58

CRC handbook of laser science and technology. Volume 3. Optical materials, Part 1 - Nonlinear optical properties/radiation damage  

Energy Technology Data Exchange (ETDEWEB)

This book examines the nonlinear optical properties of laser materials. The physical radiation effects on laser materials are also considered. Topics considered include: nonlinear optical properties; nonlinear and harmonic generation materials; two-photon absorption; nonlinear refractive index; stimulated Raman scattering; radiation damage; crystals; and glasses.

1986-01-01

59

Visual inspection technology of the narrow and small confined area for monitoring feederpipe support of pressure tube in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an ...

1999-12-01

60

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...

2011-01-01

61

Comparison and analysis of results of ? radiation level investigation around Daya Bay  

International Nuclear Information System (INIS)

Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)

2003-08-01

62

Variability of infrared stimulated luminescence properties from fractured feldspar grains  

Energy Technology Data Exchange (ETDEWEB)

A series of OSL properties of fragments from split feldspar grains have been investigated. These are (1) the response to a radiation dose, (2) the recycling of corrected induced luminescence (L{sub i}/T{sub i}), (3) the corrected natural luminescence (L{sub N}/T{sub N}), (4) the corrected thermal transfer luminescence (termed herein L{sub tt}/T{sub tt}) and, (5) the rate of anomalous fading ('g'). It was found that the parameters of different parts of the same grain are the same. The relative uncertainty, at the 2 sigma level, at which we can claim that the measured parameters are correlated, is generally less than 5% but is ca 40% for the anomalous fading rate due to measurement uncertainty. For young partially bleached sediments, the result is that one could use one fragment to evaluate the equivalent dose and another to assess the contribution of thermal transfer resulting from ...

2003-10-01

63

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, ...

2008-10-01

64

Technical note relative to the incident of the 31. october 2001 and to the fallout of ruthenium incidents occurring at Cogema-La Hague in 2001; Note technique relative a l'incident du 31 octobre 2001 et aux retombees des incidents ruthenium survenus a Cogema-La Hague en 2001  

Energy Technology Data Exchange (ETDEWEB)

It is the Office of protection against the ionizing radiations (O.P.R.I.) who alerted the A.C.R.O. that a new ruthenium incident had arisen to the factory Cogema - La Hague on October 31., 2001. The A.C.R.O. immediately made a campaign of analyses the results of which are presented in this note. The previous similar incident dates May 18., 2001. A loss of depression in the workshop R7 of the factory UP2-800 specialized in the vitrification had brought an unchecked release, by one of the smokestacks, composed essentially of radioactive ruthenium and rhodium; the evacuated activity was estimated by the operator at approximately 11 MBq. The measures in environment made by the A.C.R.O. had led the association to question the Authority of Nuclear Safety about the total quantity of release announced by the operator. Having presented the results of the measures of radioactivity in the environment made following the incident of 31. ...

2002-07-01

65

Reactivity differences of hydroxyl radicals and hydrated electrons in destructing azo dyes  

International Nuclear Information System (INIS)

The high-energy radiation-induced degradation of an H-acid derivative azo dye, Apollofix-Red SF-28 (AR-28) was studied in aqueous solution by using pulse radiolysis with kinetic spectroscopic detection for transient measurements. Gamma radiolysis with UV-VIS spectroscopy and gradient ionpair HPLC separation with diode array detection were applied for following the destruction of AR-28 and measuring the products. The reactions of hydrated electron (e_a_q "-) and hydroxyl ("#centre dot#OH) radical were investigated separately. "#centre dot#OH reacts with the unsaturated bonds of the molecule. In the further reactions of the "#centre dot#OH adduct radicals, the AR-28 molecules partly reform with a slightly modified structure. The products formed in the first reaction of "#centre dot#OH and AR-28 molecules have also high reactivity towards the "#centre dot#OH radicals. For these reasons the efficiency of ...

66

Investigation of a mineral melting cupola furnace. Part II. Mathematical modeling  

Energy Technology Data Exchange (ETDEWEB)

A mathematical model of a mineral melting cupola furnace for stone wool production has been developed for improving cupola operation. The 1-D, first-engineering-principles model includes mass and heat balances for the gas phase, five solid phases, and four liquid phases. The gas and solid/liquid phases flow countercurrently. Seven chemical reactions account for the conversions of coke, iron oxide, limestone, and gaseous species. The heterogeneous reactions of coke conversion are limited by both kinetics and mass transport. Heat transfer between phases is modeled including both convection and radiation. The model predicts gas concentrations; mass flow rates; and temperature profiles of the solid, melt, and gas in the cupola, as well as heat loss to the water-cooled walls. Inputs to the model include the coke, rock, and blast air properties, the blast air amount, and the coke percentage in the charge. The unknown model parameters are estimated on the basis of ...

2003-12-24

67

Ultraviolet radiation in Finland  

Energy Technology Data Exchange (ETDEWEB)

Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV ...

1996-12-31

68

Radiation treatment of medical devices and packaging materials. Pt. 1  

International Nuclear Information System (INIS)

The first part of the study contains a literature compilation of more than 50 original publications reporting the radiation induced effects in 17 different high polymer materials and glass which are relevant in the manufacturing of medical devices or packing materials. The results collected demonstrate that high energy radiation, i.e. gamma- or X-rays, causes various physical and chemical alterations in high polymer materials. A detailed summary and discussion of the results of the original publications is not included in the present report, it will be presented in the second part of the study. Furthermore, the second part of the study will refer to the aspect of wholesomeness of irradiated medical devices or packing materials in a more general manner of representation. (orig.).

69

Plugging indicator for controlling the sodium quality. Indicateur de bouchage pour le controle de la qualite du sodium  

Energy Technology Data Exchange (ETDEWEB)

This device has and head-race pipe with an external part and a coaxial inner part. A measuring head is mounted movable between these 2 parts and has at least a thermocouple and a mobile grid for varying the section and the sodium flow to facilitate the impurities dissolution. This ensemble is completed by a longitudinal body containing the main parts of the indicator and surrounded by a thermal exchanger to cool the sodium.

1991-09-20

70

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and ...

2006-07-01

71

Compare analysis of efficiency of using of digital and analog regimes of registration of radiation in radiometric systems of radiation thickness measuring  

International Nuclear Information System (INIS)

A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed

72

Origin of {gamma}-rays from young open clusters  

Energy Technology Data Exchange (ETDEWEB)

The young open cluster Berkeley 87 was predicted to be associated with the COS B {gamma}-ray source 2CG 075+00 on the basis of the experimental evidence of the presence of a shock front around the Wolf - Rayet star ST3 placed in the inner part of the cluster. The CGRO phase-1 data confirm this identification. Protons accelerated at the shock boundary can produce {pi} deg. via p-p interactions and then {gamma}-rays. With the measured flux F{sub {gamma}} (E > 100 MeV) {approx_equal} 9x10{sup -7} ph cm{sup -2} s{sup -1} and the power-law proton spectrum with spectral index {gamma} = 2, the cosmic-ray-energy-density in the inner part ({approx} 0.8 pc radius) of Berk 87 is about 100 times greater than that in the vicinity of the Earth. We have calculated {gamma}-ray spectra expected from the decay of {pi}{sup d}eg. produced in p-p interactions. The spectra have been normalized to the observed flux of Berk 87 by using ...

1996-08-01

73

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support ...

2000-07-01

74

Radiation Protection Aspects of the Linac Coherent Light Source Front End  

Energy Technology Data Exchange (ETDEWEB)

The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.

2010-08-26

75

The German uranium miners cohort study (Wismut cohort), 1946-2003. Technical report  

International Nuclear Information System (INIS)

From 1946 - 1990, i.e. from shortly after the end of World War II and the rise of the cold war until the German reunification, there had been extensive uranium mining both in Saxony and Thuringia, which formed the southern parts of the former German Democratic Republic. Mining activities started in Saxony in the Ore Mountains (German: Erzgebirge). Mining was conducted by a Soviet, since 1954 by a Soviet- German Incorporated Company named Wismut. It is estimated that about 400,000 persons may have worked in this time period with the company, most of them underground or in uranium ore processing facilities. In the early years, exposure to radiation and dust was particularly high for underground workers. After introduction of several ventilation measures and wet drilling from 1955 onwards, the levels of exposures to the various agents steadily decreased. After German reunification, it was decided by the German Federal Ministry ...

76

Equipment hardening and hardness assurance  

International Nuclear Information System (INIS)

The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to ...

77

Enhanced coherent undulator radiation from bunched electron beams  

International Nuclear Information System (INIS)

When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch ...

1995-09-28

78

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues  

International Nuclear Information System (INIS)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far.

2003-03-01

79

Investigations of excretion rates of the radionuclides {sup 230}Th, {sup 226}Ra, {sup 210}Pb and {sup 210}Po of persons of the general population and of workers in selected regions in Germany  

Energy Technology Data Exchange (ETDEWEB)

According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the incorporation of (mostly airborne) pollution ...

2006-07-01

80

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

81

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

82

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

83

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

84

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

85

Inhibited spontaneous emission by a Rydberg atom  

Science.gov (United States)

Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.

1985-11-11

86

EPR dosimetry in chemically treated fingernails  

UK PubMed Central (United Kingdom)

By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available

2007-08-01

87

Process of preparing metal parts to be heated by means of infrared radiance  

Energy Technology Data Exchange (ETDEWEB)

A method for preparing metal for heating by infrared radiance to enable uniform and consistent heating. The surface of one or more metal parts, such as aluminum or aluminum alloy parts, is treated to alter the surface finish to affect the reflectivity of the surface. The surface reflectivity is evaluated, such as by taking measurements at one or more points on the surface, to determine if a desired reflectivity has been achieved. The treating and measuring are performed until the measuring indicates that the desired reflectivity has been achieved. Once the treating has altered the surface finish to achieve the desired reflectivity, the metal part may then be exposed to infrared radiance to heat the metal part to a desired temperature, and that heating will be substantially consistent throughout by virtue of the desired reflectivity.

2009-06-09

88

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

89

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

90

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

91

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

92

Radiation protection  

International Nuclear Information System (INIS)

The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from ...

1988-01-01

93

Sandia National Laboratories/California site environmental report for 1997  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of SNL/California`s Environmental Monitoring ...

1998-06-01

94

Second-law efficiency of solar-thermal cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

Properly quantified performance of a solar-thermal cavity receiver must not only account for the energy gains and losses as dictated by the First Law of thermodynamics, but it must also account for the quality of that energy. However, energy quality can only be determined from the Second Law. In this paper an equation for the Second-Law efficiency of a cavity receiver is derived from the definition of available energy or availability (occassionally called exergy), which is a thermodynamic property that measures the maximum amount of work obtainable when a system is allowed to come into unrestrained equilibrium with the surrounding environment. The fundamental concepts of the entropy and availability of radiation are explored from which a convenient relationship among the reflected cone half angle, the insolation, and the concentrator geometric characteristics is developed as part of the derivation of the Second-Law ...

1983-10-01

95

Introduction of microbial nutrients in a nuclear fuel waste disposal vault as a result of excavation and operation activities  

International Nuclear Information System (INIS)

A nuclear fuel waste disposal vault would not likely be a sterile environment. Bacterial activity would be expected in those areas of the vault conducive to bacterial life, i.e., where effects of heat, moisture content, radiation and compaction would not prevent or severely restrict bacterial life and where suitable and sufficient nutrients would be present. An inventory of bacterial nutrients that would be emplaced 'intentionally' with vault materials (fuel waste, waste containers, buffer and backfill materials) has been made previously. This report assesses bacterial nutrients that would be added 'inadvertently' to a vault in the form of residues of materials used to excavate and operate a vault. Measurements of blasting material residues in the various water supplies, excavated broken rock (muck) and in cores drilled in old and new tunnel walls were made at AECL's Underground Research Laboratory. Results show that the largest potential ...

1987-08-27

96

FIB implantation induced site-selectively grown self-assembled InAs QDs in a light emitting #mu#-diode  

International Nuclear Information System (INIS)

We present an approach for fabrication of intentionally positioned epitaxial InAs QDs in a micron sized light emitting diode. For site-selective growth, a combination of molecular beam epitaxy (MBE) and focused ion beam (FIB) implantation technology in an all-ultra-high-vacuum (UHV) setup has been employed. Single dot occupancy of almost 55 % on FIB patterned nano-depressions was successfully achieved. Thereafter, carrier injection and subsequent radiative recombination from the positioned InAs/GaAs self-assembled QDs was investigated by embedding these QDs in the intrinsic part of a GaAs-based micron sized p-i-n junction device. Few or single dot are expected to be electrically addressed in these devices. We report results from electroluminescence (EL) measurement which proves the single dot characteristics of our device. The EL spectra consist of sharp emission lines and their dependence on injection current shows linear ...

2010-03-21

97

Behaviour Features of the Radiative Losses of the Torsatron U-3M Plasma  

International Nuclear Information System (INIS)

The total bolometrically measured plasma radiation losses on the RF heating power were found. The results of measurements demonstrate a nonmonotonic dependence of radiation losses on RF power. Namely, at low RF power levels (80...170 kW) the total radiation losses raised with increasing the RF power. However, the total radiation losses decreased sharply when RF power exceeded 200 kW (down to ?20 kW at 240 kW of RF power). Simultaneously, the intensity of impurity lines fell down significantly, whereas the average electron temperature (found from ECE measurement) increased. The authors consider that screening properties of periphery plasma give reasons for above experimental facts.

2006-01-01

98

On the space-time scales of the surface solar radiation field  

Energy Technology Data Exchange (ETDEWEB)

The characteristic space-time scales of surface solar radiation fields measured by the 111-instrument ME-SONET in Oklahoma are estimated after removal of the diurnal cycle. These estimates of {open_quotes}within-day{close_quotes} are used to deduce the representativeness of surface solar radiation measurements measurement site as a function of time-averaging interval. Nomograms of the relation between point measurements and area averages are given for different space-time-averaging intervals. Examples from the nomograms show, for instance, that under conditions of low mean radiation (cloudy days), the central site point measurements are representative of a spatial area the size of a T42 GCM grid box (280 km X 280 km) if one uses hourly averages and is willing to accept a correlation of 0.45 between area average and point ...

1998-01-01

99

The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)  

International Nuclear Information System (INIS)

As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.

100

Radiation preservation of foods of plant origin. Part IV. Subtropical fruits: citrus, grapes, and avocados  

Energy Technology Data Exchange (ETDEWEB)

Current information on the use of ionizing radiation for improving the storage of subtropical fruits like citrus, grapes, and avocados is reviewed. The feasibility of applying radiation either alone or in combination with other physical or chemical treatments for the control of postharvest fungal diseases is considered. Irradiation effects on the physiology of the fruits as related to respiration, ethylene evolution, changes in major chemical constituents, and quality are discussed. The recent trends in the possible use of irradiation as an alternative treatment to chemical fumigants for disinfestation of citrus and avocados and the prospects for the future application of irradiation for preservation of some of these fruits are outlined. 128 references.

1986-01-01

101

Radiation hardening of semiconductor parts  

International Nuclear Information System (INIS)

This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.

102

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

103

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

Science.gov (United States)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and ...

2008-05-01

104

Towards Resonant-State THz Laser Based on Strained p-Ge ...  

Science.gov (United States)

... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...

2006-07-01

105

Measured Temperatures of Solid Rocket Motors Dump Stored ...  

Science.gov (United States)

... TARGET SENSOR-MK 80 SERIES BOMBS ... 5-inch-, and 2.75-inch- diameter rocket motors that ... balance when compared to incoming solar radiation ...

1989-07-01

106

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

107

Anthropogenic materials and products containing natural radionuclides. Pt. 2a. Investigation of occupational radiation doses. Specific and long-term measurements in a drinking-water conditioning plant; Anthropogene Stoffe und Produkte mit natuerlichen Radionukliden. T. 2a. Untersuchungen zur Strahlenexposition beim beruflichen Umgang. Detail- und Langzeitmessungen in einer Trinkwasseraufbereitungsanlage  

Energy Technology Data Exchange (ETDEWEB)

The measuring series was performed from November 1991 through April 1992 in seven drinking-water conditioning plants of the Fichtel mountains area in the north-eastern part of Bavaria, and the results revealed as an annual average a dose of about 1 - 40 WLM. The area of interest is a drinking-water catchment area where the ground water and other water resources include waters particularly rich in radon content, which explains this relatively high dose range. This is why comprehensive, specific local and long-term mearurements were carried out in order to assess the occupational radiation dose in the drinking-water conditioning plants, taking as a model site the conditioning plant of the municipal utilities of Hof in Weissenstadt. These more specific measurements were performed by the Technical Inspectorates (TUeV) of Bavaria and Saxony and the isotope laboratory of Georg-August University of Goettingen ...

1995-03-01

108

Measuring characteristics on emissivity using infrared thermometer for RCCS  

International Nuclear Information System (INIS)

In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while ...

2004-12-01

109

Self-assessment of current knowledge in nuclear medicine (second edition)  

Energy Technology Data Exchange (ETDEWEB)

In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. ...

1981-01-01

110

Radioanalytical chemistry. Vol. 2  

International Nuclear Information System (INIS)

This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).

1989-01-01

111

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

112

Radiation doses and somatic risk to patients during cardiac radiological procedures  

International Nuclear Information System (INIS)

The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).

1986-01-01

113

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

114

Investigation of radiation defects in solids using the EXAFS method  

International Nuclear Information System (INIS)

The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons.

1978-02-15

115

Evaluation of radiation resistance of cable connector material  

Energy Technology Data Exchange (ETDEWEB)

Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.

2002-10-01

116

Using knowledge brokers to facilitate the uptake of pediatric measurement tools into clinical practice: a before-after intervention study  

UK PubMed Central (United Kingdom)

BackgroundThe use of measurement tools is an essential part of good evidence-based practice; however, physiotherapists (PTs) are not always confident when selecting, administering,...Full Text Available

117

A.C.R.O. activity report 2002; A.C.R.O. rapport d'activite 2002  

Energy Technology Data Exchange (ETDEWEB)

A.C.R.O. (Association pour le Controle de la Radioactivite dans l Ouest) is a French non governmental organisation that operates a laboratory for radioactivity analysis. It was created in 1986 as a response to people demands for information and reliable, independent testing. The organisation mainly carries out missions of information and training for its correspondents and more generally for a wide audience, particularly for people who worry about problems of environment, health, management of radioactive waste and emissions. Thanks to its structure, it enables citizens to involve themselves together with scientists so as to gain access to information that was hither to reserved to specialists. The organisation can vouchsafe its independence from the diversity of its members and volunteers, as well as from the diversity of its money resources. Besides its headquarters situated on the city of Caen area (Normandy), three branches situated in North Normandy, in Touraine and North Cotentin ...

2002-07-01

118

On Sensitivity of Spectral Radiative Fluxes to Atmospheric Water Vapor in the 940 nm Region (Numerical Simulation)  

Energy Technology Data Exchange (ETDEWEB)

Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...

2005-03-18

119

Measurements of x-ray radiation dose levels during radiological examination in Jos university teaching hospital and Plateau state specialist hospital  

International Nuclear Information System (INIS)

In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.

2008-10-15

120

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

121

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is ...

1980-01-01

122

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation ...

1995-10-01

123

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

124

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal ...

1986-01-01

125

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

126

Basic mechanisms of radiation effects in the natural space radiation environment  

Energy Technology Data Exchange (ETDEWEB)

Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)

1994-06-01

127

The importance and unique aspects of radiation protection in medicine  

British Library Electronic Table of Contents (United Kingdom)

Radiation protection in medicine has unique aspects and is an essential element of medical practice. Medical uses of radiation occur throughout the world, from large cities to rural clinics. It has been estimated that the number of medical procedures using radiation grew from about 1.7 billion in 1980 to almost 4 billion in 2007. In spite of these large numbers, there are many parts of the world without adequate equipment, where the ability to perform additional medical procedures would likely result in a net benefit. Medicine accounts for more than 99.9% of the per caput effective dose from man-made sources. The goal in medical exposure is not to give the lowest dose, but to provide the correct dose to enable the practitioner to make the diagnosis or cure a tumour. Too little or too much ...

2010-01-01

128

The SOS-LUX-TOXICITY-Test on the International Space Station  

British Library Electronic Table of Contents (United Kingdom)

For the safety of astronauts and to ensure the stability and integrity of the genome of microorganisms and plants used in bioregenerative life support systems, it is important to improve our knowledge of the combined action of (space) radiation and microgravity. The SOS-LUX-TOXICITY test, as part of the TRIPLE-LUX project (accepted for flight at Biolab in Columbus on the International Space Station, (ISS)), will provide an estimation of the health risk resulting from exposure of astronauts to the radiation environment of space in microgravity. The project will: (i) increase our knowledge of biological/health threatening action of space radiation and enzymatic DNA repair; (ii) uncover cellular mechanisms of synergistic interaction of microgravity and space radiation; (iii) provide specified...

2006-01-01

129

Report on NCI symposium: comparison of mechanisms of carcinogenesis by radiation and chemical agents. II. Cellular and animal models  

International Nuclear Information System (INIS)

The point at which the common final pathway for induction of cancer by chemical carcinogens and ionizing radiation has not been identified. Although common molecular targets are suggested by recent findings about the role of oncogenes, the mechanism by which the deposition of radiation energy and the formation of adducts or other DNA lesions induced by chemicals affects the changes in the relevant targets may be quite different. The damage to DNA that plays no part in the transformation events, but that influences the stability of the genome, and therefore, the probability of subsequent changes that influence tumorigenesis may be more readily induced by some agents than others. Similarly, the degree of cytotoxic effects that disrupt tissue integrity and increase the probability of expression of initiated cells may be dependent on the type of carcinogen. Also, evidence was presented that repair of the initial lesions could ...

1984-05-20

130

Time Average Aerodynmic Forces and Moments on a National Model of a Semi-Submersible Offshore Rig. Part 1. Measurements. Part 2. Analysis of Results for the Basic Model.  

Science.gov (United States)

Wind-tunnel measurements were taken of the time-average aerodynamic forces and moments on a notional model of a semi-submersible offshore drilling rig at two heights and at various attitudes to the wind. Attempts were made to analyze the separate effects ...

1982-01-01

131

Reflectance, Optical Properties, and Stability of Molybdenum/Strontium and Molybdenum/Yttrium Multilayer Mirrors  

Energy Technology Data Exchange (ETDEWEB)

The motivation of this work is to develop high reflectance normal-incidence multilayer mirrors in the 8-12 nm wavelength region for applications in astronomy and extreme ultraviolet lithography. To achieve this goal, Mo/Sr and Mo/Y multilayers were studied. These multilayers were deposited with a UHV magnetron sputtering system and their reflectances were measured with synchrotron radiation. High normal-incidence reflectances of 23% at 8.8 nm, 40.8% at 9.4 nm, and 48.3% at 10.5 nm were achieved. However, the reflectance of Mo/Sr multilayers decreased rapidly after exposure to air. Attempts to use thin layers of carbon to passivate the surface of Mo/Sr multilayers were unsuccessful. Experimental results on the refractive index {tilde n} = 1-{delta} + i{beta} of yttrium and molybdenum in the 50-1300 eV energy region are reported in this work. This is the first time ever that values on the refractive index of yttrium are ...

2002-09-01

132

Absorption of 308-nm excimer laser radiation by balanced salt solution, sodium hyaluronate, and human cadaver eyes  

Energy Technology Data Exchange (ETDEWEB)

Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning ...

1990-11-01

133

Relaxation oscillation of amplified spontaneous radiation pulse emitted from a single-mirror Cu/CuBr laser  

Energy Technology Data Exchange (ETDEWEB)

The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.

1985-10-01

134

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

135

Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note  

Energy Technology Data Exchange (ETDEWEB)

The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.

1986-01-01

136

Weakly penetrating radiation monitoring and assessment at Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)

2006-05-01

137

Rayleigh scattering of Moessbauer radiation in hyaluronate oriented fibres  

Energy Technology Data Exchange (ETDEWEB)

The Rayleigh scattering of Moessbauer radiation has been measured on highly oriented fibres of Na-hyaluronate at different hydration levels. The elastic- and-inelastic-scattering intensities, measured as a function of the scattering vector Q, have provided information on the dynamic structuring of the water molecules to the polysaccharidic chains.

1996-02-01

138

Measurement of radiative, Auger, and nonradiative currents in 1. 3-. mu. m InGaAsP buried heterostructure lasers  

Energy Technology Data Exchange (ETDEWEB)

Frequency response measurements are used to determine the carrier lifetime of 1.3-..mu..m InGaAsP buried heterostructure lasers between 1 mA and threshold. The data confirm previous results on the radiative and Auger recombination coefficients and reveal the presence of a nonradiative current which dominates at low currents and contributes 4 mA at threshold.

1987-02-09

139

Numerical simulation and experiment research of radiation performance in a dish solar collector system  

British Library Electronic Table of Contents (United Kingdom)

The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.

2010-01-01

140

Effect of substrate on the results of measuring coating thickness according to radiation scattered by substrate  

International Nuclear Information System (INIS)

The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.

141

A Year of Radiation Measurements at the North Slope of Alaska Second Quarter 2009 ARM and Climate Change Prediction Program Metric Report  

Energy Technology Data Exchange (ETDEWEB)

In 2009, the Atmospheric Radiation Measurement (ARM) Program and the Climate Change Prediction Program (CCPP) have been asked to produce joint science metrics. For CCPP, the second quarter metrics are reported in Evaluation of Simulated Precipitation in CCSM3: Annual Cycle Performance Metrics at Watershed Scales. For ARM, the metrics will produce and make available new continuous time series of radiative fluxes based on one year of observations from Barrow, Alaska, during the International Polar Year and report on comparisons of observations with baseline simulations of the Community Climate System Model (CCSM).

2009-04-15

142

CFD investigation of balcony spill plumes in atria (part II)  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes an integrated method for using experimental data and CFD modeling to develop engineering correlations for atrium smoke management. Part I focused on the experimental program and validation of a CFD model of the experimental facility. Part II describes the extension of this model to a parametric study of balcony spill plumes. Smoke management in buildings during fire events often uses mechanical ventilation systems to maintain smoke layer elevation above a safe evacuation path. Design of these systems requires accurate correlations for the smoke production or mass flow rate of the buoyant fire plume. One design issue is the mass flow rate of fire plumes which spill out from a fire compartment, under a balcony and up through an atrium or other large volume. Current engineering correlations for these balcony spill plumes (BSPs) are based on a combination of one-tenth scale test data and theoretical analysis. The suitability of ...

2005-07-01

143

CFD investigation of balcony spill plumes in atria (part II)  

International Nuclear Information System (INIS)

This paper proposes an integrated method for using experimental data and CFD modeling to develop engineering correlations for atrium smoke management. Part I focused on the experimental program and validation of a CFD model of the experimental facility. Part II describes the extension of this model to a parametric study of balcony spill plumes. Smoke management in buildings during fire events often uses mechanical ventilation systems to maintain smoke layer elevation above a safe evacuation path. Design of these systems requires accurate correlations for the smoke production or mass flow rate of the buoyant fire plume. One design issue is the mass flow rate of fire plumes which spill out from a fire compartment, under a balcony and up through an atrium or other large volume. Current engineering correlations for these balcony spill plumes (BSPs) are based on a combination of one-tenth scale test data and theoretical analysis. The suitability of ...

144

Nylon resin steadily infiltrating into the structural parts use field. Kiko buhin to shtie chakujitsuni shintosuru nairon jushi  

Energy Technology Data Exchange (ETDEWEB)

Considerations were given on typical applications of nylon resin parts to automotive use and their future trends through news topics. GF strengthened nylon resin is used in cylinder head covers substituting aluminum because of advantages in nylon resin of weight reducibility, vibration suppressibility, and noise shielding capability. Radiator tank uses N66GF 30% strengthened nylon in more than 60% of bonnet type passenger cars. Nylon resin is used most in harness connectors installed in locations that require heat resistance. External car parts such as bumpers, fenders, and wheel caps use to some extent nylon resin in the form of strengthened and up-graded polymer alloy. BMW in Germany used in its high-class production cars intake manifolds made of GF strengthened Nylon 66. The majority of engine{prime}s gas intake system parts has been replaced with Nylon blow-formed parts. The ...

1992-06-18

145

Rising Total Hadron-Hadron Cross Sections  

CERN Document Server

A historical summary is made on the measurements concerning the rising total hadron-hadron cross sections at high energies. The first part of this paper concerns the total cross section measurements performed at the Brookhaven, Serpukhov and Fermilab fixed target accelerators; then the measurements at the CERN Intersecting Storage Rings (ISR), and at the CERN and at the Tevatron Fermilab proton-antiproton colliders; finally the cosmic ray measurements at even higher energies. A short discussion on Conclusions and Perspectives follows.

2007-01-01

146

Radioactivity of people in Finland after the Chernobyl accident in 1986  

International Nuclear Information System (INIS)

After the reactor accident at Chernobyl on April 26, 1986 radioactive fallout was carried by air currents to most parts of Europe. The radioactive air currents reached Finland on April 27. Immediately after the arrival of such air in Finland, contamination of people by radioactive nuclides began via inhalation of this air. The ingestion route become important later, when radionuclides were transported via different foodchains to man. To determine the level of radionuclides in the body and to estimate the internal radiation doses caused by the Chernobyl accident, whole-body counting measurements were performed. The results of whole-body counting of six different groups of Finnish people measured during 1986 after the accident at Chernobyl are reported. Three were reference groups measured routinely once or twice annually, two groups were comprised of workers at nuclear power stations ...

2004-02-01

147

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) ...

1988-01-01

148

Manufacture of wood/plastic composites by radiation  

International Nuclear Information System (INIS)

The manufacture and use of wood/plastic composite (WPC) as an example of wood matrix and wood sawdust/plastic composites (SDP) as an example of plastic matrix are reviewed. The raw material for WPC are mostly vinyl monomers, particularly methyl methacrylate and styrene. The reaction in WPC polymerization is radical polymerization. Researches on the radiation sources mostly resulted in gamma-ray. Electron beam can be applied only to thin products. The future use of WPC may be for furnitures, sporting goods, decorative parts and the like. Vital study on the reduction of manufacturing costs is required, for example, the improvement of reaction and the adoption of continuous process must be considered. The raw materials for SDP are wood sawdust, vinyl monomer (mostly methyl methacrylate) and resins. Electron beam accelerators are the most preferable radiation source because of its high efficiency and safe operation. SDP shows ...

1976-01-01

149

Environmental hardening of a mobile-manipulator system for nuclear environments  

International Nuclear Information System (INIS)

This research report discusses the radiation hardening of a commercially available mobile robot, the REMOTEC ANDROS. This hardening effort is culminating in the availability of a megarad hardened mobile platform to access areas in nuclear facilities with extremely high levels of radiation (0.1 to 1 Mrad). These radiation levels may be encountered both during routine repair and monitoring activities and accident situations. The project has completed a phase-I U.S. Department of Energy Small Business Innovative Research contract and is now in a phase-II effort with completion scheduled in early 1995. The research involves the evaluation of the material and electrical components of an ANDROS robot to determine the anticipated radiation hardness of the current production version and evaluation of the components that must be replaced or modified to harden the system to higher radiation ...

1993-11-14

150

Effective per-capita dose as a yardstick for medical radiation exposure of the population - a supplement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant ...

1984-06-01

151

Effect of antioxidants on aging of nuclear plant cable insulation  

International Nuclear Information System (INIS)

The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants ...

152

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted ...

153

Health effects models for nuclear power plant accident consequence analysis. Modification of models resulting from addition of effects of exposure to alpha-emitting radionuclides: Revision 1, Part 2, Scientific bases for health effects models, Addendum 2  

Energy Technology Data Exchange (ETDEWEB)

The Nuclear Regulatory Commission (NRC) has sponsored several studies to identify and quantify, through the use of models, the potential health effects of accidental releases of radionuclides from nuclear power plants. The Reactor Safety Study provided the basis for most of the earlier estimates related to these health effects. Subsequent efforts by NRC-supported groups resulted in improved health effects models that were published in the report entitled {open_quotes}Health Effects Models for Nuclear Power Plant Consequence Analysis{close_quotes}, NUREG/CR-4214, 1985 and revised further in the 1989 report NUREG/CR-4214, Rev. 1, Part 2. The health effects models presented in the 1989 NUREG/CR-4214 report were developed for exposure to low-linear energy transfer (LET) (beta and gamma) radiation based on the best scientific information available at that time. Since the 1989 report was published, two addenda to that report have been prepared to (1) ...

1993-05-01

154

Nuclear reactor with external structure cooling by natural convection  

International Nuclear Information System (INIS)

The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.

155

Linac based free-electron laser  

International Nuclear Information System (INIS)

A basic treatment of the principle of the linac-driven free-electron laser (FEL) is given. The first part of the paper describes the FEL in low-gain approximation, and in the second part the high-gain FEL theory is given. The majority of the treatment describes FELs in one dimensional approximation, neglecting effects by diffraction of radiation and by electron beam emittance. Only in the final section a few remarks on these issues are given. The ambition of the paper is by no means any progress in FEL theory but a clear presentation of basic FEL theory concepts with explicit derivation of the formulae from first principles. (orig.)

156

Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the ARPANSA and the BIPM in low-energy X-rays  

International Nuclear Information System (INIS)

A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)

2010-12-01

157

Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden  

Energy Technology Data Exchange (ETDEWEB)

The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically ...

2007-11-15

158

Solar power station. Sonnenkraftwerk  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a solar power station with a hollow solar heater, which has reflected radiation coming in, focussed by a mirror through the inlet opening. To match the differing solar radiation during the day, the inlet opening can be adjusted by changing its cross-section. This is done by at least two thick flat circular parts which can move relative to each other which are preferably movable relative to each other in pairs on a common rail and which are cooled by a coolant which is the working medium for absorbing solar energy.

1982-02-25

159

Complex radiation degradation behaviour of PVC materials under accelerated aging conditions  

International Nuclear Information System (INIS)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the levelling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests. (author).

1982-10-01

160

Complex radiation degradation behavior of PVC materials under accelerated aging conditions  

Energy Technology Data Exchange (ETDEWEB)

The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the leveling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests.

1983-07-01

161

Noise spectral density measurements of a radiation hardened CMOS process in the weak and moderate inversion  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the noise of MOS transistors of the United Technology Microelectronics Center (UTMC) 1.2 [mu]m radiation hardened CMOS P-well process from the weak to moderate inversion region. The noise power spectral densities of both NMOS and PMOS devices were measured from 1 KHz to 50 MHz. The bandwidth was chosen such that the important components of the spectral densities such as the white thermal noise and the 1/f noise could be easily resolved and analyzed in detail. In this paper the effects of different device terminal DC biases and channel geometries on the noise are described.

1992-08-01

162

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the ...

163

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

164

The effective per caput dose equivalent as a measure of medical radiation exposure of the population - a complement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population exposure to different ...

1984-01-01

165

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

166

Emission of {sup 14}C by the Almirante Alvaro Alberto Nuclear Power Plant 1 and 2 and their local effects on the environmental levels; Emissao de {sup 14}C pelas unidades 1 e 2 da Central Nuclear Almirante Alvaro Alberto (CNAAA) e seu efeito local nos niveis ambientais  

Energy Technology Data Exchange (ETDEWEB)

{sup 14}C is a is a long-lived beta-emitting nuclide (T{sub 1/2} = 5730 years) produced naturally in the upper atmosphere as a result of reactions between neutrons and stable {sup 14}N({sup 14}N(n,p){sup 14}C). Although in a lesser extent, nuclear power plants produce {sup 14}C as well during their routine operation. Since it is converted in {sup 14}CO{sub 2} and mixed throughout the atmosphere, it is incorporated into plant tissues, via photosynthesis process, and hence in food chain. Because of the biological importance of {sup 14}C and long half-life, it is of interest to quantify the amounts released by nuclear industry. The Brazilian nuclear central named Nuclear Central Admiral Alvaro Alberto (CNAAA) has two nuclear reactors of PWR type in operation, Angra I (657 MWe) and Angra II (1350 MWe), and one under construction, Angra III (1309 MWe PWR). The aim of this study was to determine the strength of the sources and the {sup 14}C content in the environment through analyses of air, ...

2006-07-01

167

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder ...

2003-03-04

168

Surgical aspects of intestinal injury due to pelvic radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is suggested.

1985-04-01

169

Nuclear techniques for measuring moisture content in soil profiles  

International Nuclear Information System (INIS)

The prevailing severe shortage of animal feed in most of the developing countries could, to a considerable extent, be overcome through improved range management, which includes introduction of high yielding drought-resistant forage crops, development of adequate water conservation measures, and as far as possible growing annual forage crops on part of the vast areas of arable land currently left fallow each year. Year round measurements are essential for a good understanding of soil water and nutrients dynamics, which allow for adequate evaluation of pasture management alternatives. The methods most commonly used for moisture measurements in soil profiles are discussed because such measurements are likely to form an essential part of any investigation aimed at increasing animal feed production through the development of adequate pasture management practices. ...

170

Experimental and theoretical analysis of compression ratio on Otto-cycle engines. Pt. 1  

Energy Technology Data Exchange (ETDEWEB)

The increase of the compression ratio of Otto carburator engines up to epsilon = 14 was investigated by Audi in its research department at Neckarsulm. The results are presented in three partial reports. Part one describes the Audi fuel method and demonstrates the effects of the main parameters. Part two shows the influence of the current on the combustion by the help of a new measuring method developed by the Institut fuer Physikalische Elektronik at Stuttgart University. Part three provides a theoretical analysis of the data gained in the investigations.

1982-01-01

171

Calculation of eddy current losses in metal parts of power transformers  

Energy Technology Data Exchange (ETDEWEB)

To maintain quality, performance and competitiveness, the eddy current losses in metal parts of power transformers in the range of 50-200 MVA are investigated in a more detailed form. The finite element calculations utilize different modelling strategies for the current carrying metal parts. Several global and local results are further used to obtain simplified calculation approaches for an inclusion in the initial design and the design optimization. The results from two finite element approaches using nodal and edge based formulations will be compared with measurements. (Author)

2003-04-01

172

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

173

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

174

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

175

Dimensional metrology and positioning operations: basics for a spatial layout analysis of measurement systems  

CERN Document Server

Dimensional metrology and positioning operations are used in many fields of particle accelerator projects. This lecture gives the basic tools to designers in the field of measure by analysing the spatial layout of measurement systems since it is central to dimensional metrology as well as positioning operations. In a second part, a case study dedicated to a synchrotron storage ring is proposed from the detection of the magnetic centre of quadrupoles to the orbit definition of the ring.

2010-01-01

176

Use of high energy radiation component as a reference source for radiometric testing  

International Nuclear Information System (INIS)

The possibility of providing high accuracy of absorption and albedo methods of radiometric testing due to the use of high-energy radiation component that has passed through a barrier and gone from it in the opposite direction as a reference source, is considered. It is shown that the use of high-energy component of penetrating radiation as a reference source decreases the device response to the main interference in a much larger degree than its response to the change of measured parameter. Experiments are performed using steel pipes and plates. "2"4"1Am, "1"3"7Cs and "6"0Co are used as sources.

177

The effect of temperature on the radiative performance of Ho-YAG thin film selective emitters  

Energy Technology Data Exchange (ETDEWEB)

The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.

1995-01-01

178

Radiological hazards in uranium mines and a yellow-cake plant in Turkey  

Energy Technology Data Exchange (ETDEWEB)

Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.

1984-06-01

179

Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985  

Energy Technology Data Exchange (ETDEWEB)

Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.

1985-05-01

180

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

181

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

182

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

183

ESR spectra of radicals of gamma-irradiated wood and cellulose  

International Nuclear Information System (INIS)

Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.

184

CRC handbook of biological effects of electromagnetic fields  

Energy Technology Data Exchange (ETDEWEB)

This book presents the current knowledge about the effects of electromagnetic fields on living matter. The three-part format covers dielectric permittivity and electrical conductivity of biological materials; effects of direct current and low frequency fields; and effects of radio frequency (including microwave) fields. The parts are designed to be consulted independently or in sequence, depending upon the needs of the reader. Useful appendixes on measurement units and safety standards are also included.

1986-01-01

185

Application of an on-line measurement system for HF emission control (2. part); Application d'un systeme de mesure en ligne pour le controle des emissions de fluor (2. partie)  

Energy Technology Data Exchange (ETDEWEB)

In the last issue of 'L'Industrie ceramique et verriere', we presented the first part of this study. We describe in this issue the experimental procedure, the results and the conclusions of this work. (authors)

2005-02-01

186

Natural radioactivity  

International Nuclear Information System (INIS)

This chapter discusses the types of natural radioactive materials in the environment that include primordial natural radioactive materials such as K-40, U and Th, and daughters of their decay series. The discussion also includes secondary natural radioactive material generated through cosmic radiation interaction with nucleus of materials in the atmosphere. The dispersion of these radioactive materials to environment will also be part of the discussion. (Author)

187

Overview of bunch length measurements.  

Energy Technology Data Exchange (ETDEWEB)

An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.

1999-02-19

188

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

189

Quantum locking of mirrors in interferometric measurements  

International Nuclear Information System (INIS)

We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.

2004-03-07

190

In Vivo Measurement of Indole-3-acetic Acid Decarboxylation in Aging Coleus Petiole Sections  

UK PubMed Central (United Kingdom)

The concentration of indoleacetic acid (IAA) in plant tissues is regulated, in part, by its rate of decarboxylation. However, the commonly used in vitro assays for IAA oxidase may not...Full Text Available

1983-09-01

191

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 3. Design Case Studies.  

Science.gov (United States)

Contents: Introduction; Design Criteria for a Green Building; Comparison of Energy Efficiency Measures; Whole House Energy Efficiency; Built Examples of Energy Efficient Houses; and Product Energy of Building Elements.

1993-01-01

192

Characterization of atmospheric aerosol near motor way: Bassa Valle Susa (Italy); Caratterizzazione dell`aerosol atmosferico in prossimita` di un`autostrada: Bassa Valle Susa  

Energy Technology Data Exchange (ETDEWEB)

Results related to the experimental measurement campaign to characterize atmospheric aerosol carried out near Avigliana (Turin) from 18 to 22 October 1994 are presented in this paper. In the frame of the project aimed at evaluating the impact of the mountain motor way A-32 Rivoli-Bardonecchia-Frejus on the Susa Valley environment and on man the present measurement campaign is the second, and last, one envisaged in the project. The sampling place is in the initial part of the Susa Valley while previous measurements were carried out in the high part of it. Mass mean concentrations result greater in the low than in the high part of the valley approximately by a factor of 3. It is not possible to prove a difference between the 3 sampling positions transversely placed from 20 to 80 m. in comparison with the motor way axis. Whereas mass mean concentrations dropped ...

1995-10-01

193

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

194

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

195

Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole  

Energy Technology Data Exchange (ETDEWEB)

Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.

1996-12-31

196

Radiation treatment of some poultry products  

International Nuclear Information System (INIS)

Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.

1988-09-26

197

Investigation of Moessbauer radiation diffraction on Fe/sub 3/BO/sub 6/ monocrystal. Nuclear transition interference  

Energy Technology Data Exchange (ETDEWEB)

Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurement results are compared with theoretical calculations.

1984-05-25

198

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

199

Domestic radon exposures in the UK  

Energy Technology Data Exchange (ETDEWEB)

Radon in the home is the main source of exposure to ionising radiation for most people. In 1990 the National Radiological Protection Board issued revised advice to the United Kingdom Government on standards of protection against radon in the home. A description is offered of the survey work being undertaken by the Board which includes radiation measurements of thousands of homes in the United Kingdom. (author).

1991-09-01

200

Computer simulation and radiation hardening of power devices to protect against failures induced by heavy ions  

International Nuclear Information System (INIS)

Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).

201

Metrology measurement capabilities  

Energy Technology Data Exchange (ETDEWEB)

Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. ...

1997-06-01

202

Go vs. no-go - potential and limitations of continuous-variable quantum computing by measurements  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we explore the feasibility of quantum computation using continuous-variable systems by means of local measurements only. In the first part of the talk, we will identify crucial limitations that arise when starting from Gaussian cluster states. This is done by resorting to a Gaussian projected entangled pair picture as well as to notions of continuous-variable quantum repeater networks. In the second part, we look at instances in which these limitations can be overcome, and how suitable encodings of qubits in oscillators and feasible non-Gaussian resource states give rise to universal schemes for quantum computing.

2010-07-01

203

STS-83 - Johnson Space Center - NASA  

Science.gov (United States)

Radiation Measurement in Crew Compartment. DTO 805: .... spacecraft and aircraft propulsion, and hazardous waste disposal. ...... combustion reactions in a turbulent chemical kinetic flow reactor using laser induced fluorescence and ...

204

SEE Characterization of the Samsung K4F660812 DRAM ... - NEPP - NASA  

Science.gov (United States)

the Samsung K4F660812 DRAM were measured by the JPL Radiation Effects. Group [1] . ... The Samsung K4F660812 is a 8 x 223 bit Fast Page CMOS DRAM. The two- ...

205

Emergency Reference Levels: Criteria for Limiting Doses to the Public in the Event of Accidental Exposure to Radiation.  

Science.gov (United States)

Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...

1981-01-01

206

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been ...

1997-07-01

207

Critical current density and dissipation in sintered YBCO filaments  

Energy Technology Data Exchange (ETDEWEB)

Critical current density and dissipation of four sintered YBCO filaments were measured using a continuous DC power supply. Each sample exhibited somewhat different characteristics from the others even though 3 of the 4 samples are from the same batch. The data suggest that it is possible for the YBCO filament to be in a state of stable equilibrium when part of the filament is in the flux-flow state and part of the filament is in the normal state (local hot spots). This behavior may be advantageous for resistive fault current limiters because the intermediate state (partly flux-flow and partly normal) has an overall resistance much higher than that of the flux-flow state but it does not lead to thermal runaway (burnout) or excessive heating compared to a YBCO filament driven into normal state over its entire length. Two of the samples were broken as a result of local burnout.

1997-09-01

208

Computer and Network Security in Small Libraries: A Guide for Planning.  

Science.gov (United States)

This manual is intended to provide a free resource on essential network security concepts for non-technical managers of small libraries. Managers of other small nonprofit or community organizations will also benefit from it. An introduction defines network security; outlines three goals of network security; discusses why a library should be concerned with network security; and describes limits of this work. The manual is divided into three main parts. Part One features the management issues related to network security: analyzing risk, developing a security plan and policy, the funding requirements libraries can expect in operating their networks, and implementing adequate security. Part Two describes the areas of computer networks that need to be secured, and provides a description of many of the security measures necessary for adequate security. Part Three presents sample ...

2000-12-01

209

Effect of radiation on some prepared polymeric moulds for use in environmental applications  

International Nuclear Information System (INIS)

The aim of this study is to prepare some polymeric moulds using Natural rubber latex (NRL)- portland cement composites based on a delayed-action mechanism. Factors affecting the preparation process such as concentration, mixing percentage, additives and their effects on what is regarded as a delayed-action coacervant combination was studied. The effect of Gamma-radiation on the mechanical properties of these moulds was investigated. The effect of natural aging on the prepared moulds was investigated to determine the possibility of using the prepared product in the construction field as expansion joints and cracks filling materials ...etc. The results may be summarized as follows: 1) Composites of natural rubber latex (NRL)-portland cement mould were prepared as two separate parts. The stabilized natural rubber latex (NRL) with hydroxy ethyl cellulose (HEC) as stabilizer and a delayed-action coacervant (sodium meta silicate) present in the ...

210

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. ...

2006-11-13

211

Secondary hazards of high power laser beam welding  

International Nuclear Information System (INIS)

Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)

1996-01-01

212

Forward directed Smith-Purcell radiation from relativistic electrons  

International Nuclear Information System (INIS)

The requirements for the generation of forward directed Smith-Purcell emission from relativistic electrons are introduced, and the first experimental evidence of this phenomenon is presented. The experiments were conducted with a 2.8 MeV/c electron beam interacting with a 1 cm period grating. Radiation emitted in two bands with wavelengths ranging from 600 to 650 #mu#m and 1.2 to 1.7 mm were measured. Grating period to wavelength ratios were as high as 16. The measured intensities are higher than that predicted by incoherent emission.

213

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

214

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

Energy Technology Data Exchange (ETDEWEB)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

1999-07-01

215

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

International Nuclear Information System (INIS)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

216

Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1995--31 August 1996  

Energy Technology Data Exchange (ETDEWEB)

The Triangle Universities Nuclear Laboratory (TUNL)--a collaboration of Duke University, North Carolina State University, and the University of North Carolina at Chapel Hill--has had a very productive year. This report covers parts of the second and third year of a three-year grant between the US Department of Energy and the three collaborating universities. The TUNL research program focuses on the following areas: precision test of parity-invariance violation in resonance neutron scattering at LANSCE/LANL; parity violation measurements using charged-particle resonances in A = 20--40 targets and the A = 4 system at TUNL; chaotic behavior in the nuclei {sup 30}P and {sup 34}Cl from studies of eigenvalue fluctuations in nuclear level schemes; search for anomalies in the level density (pairing phase transition) in 1f-2p shell nuclei using GEANIE at LANSCE/LANL; parity-conserving time-reversal noninvariance tests using {sup 166}Ho resonances at ...

1996-09-01

217

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ...

2007-04-07

218

Genotoxicity of 2-alkylcyclobutanones, markers for an irradiation treatment in fat-containing food--Part I: cyto- and genotoxic potential of 2-tetradecylcyclobutanone  

International Nuclear Information System (INIS)

Previous experiments had indicated a slight genotoxic potential both in rat and in human colon cells of a sample of 2-dodecylcyclobutanone, a compound formed by irradiation of food containing palmitic acid in its triglycerides. Up to date, there is no evidence that 2-alkylcyclobutanones occur in non-irradiated foodstuffs, consequently it is prudent to test several members of the class of 2-alkylcyclobutanones which are produced by treatment of fat-containing food with ionising radiation. In this work, 2-tetradecylcyclobutanone (derived from stearic acid) has been tested for its cytotoxic and genotoxic potential. Human colon tumor cell lines, i.e. HT 29 and HT 29 clone 19A, were employed as models for in vitro experiments for cytotoxicity and genotoxicity tests. Cytotoxicity was measured by tetrazolium salt reduction assays (MTT and WST-1) and genotoxicity by determining DNA damage using the Comet Assay. Neither cytotoxic nor genotoxic effects ...

2002-03-01

219

Enhanced spectral discrimination through the exploitation of interface effects in photon dose data  

International Nuclear Information System (INIS)

The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous lung/water, the lung ...

2004-02-01

220

Aerosol Physical, Optical and Chemical Properties during African Dust Events at Cape San Juan (CPR)  

Science.gov (United States)

Large amounts of atmospheric dust are lifted from the North African deserts and are transported by the trade winds over the Caribbean region, especially during the summer months. How African dust particles influence the earth's radiative budget is not well understood because these particles are highly variable and their physical, optical, and chemical properties are poorly characterized, especially when they are atmospherically processed as are those that travel from Africa to the Caribbean region. Here we present results of aerosol measurements performed at Cape San Juan (CPR), a ground-based station located at the northeastern tip of the Caribbean island of Puerto Rico. We used a condensation particle counter to determine the particle number concentration, a sunphotometer (part of the AErosol RObotical NETwork, AERONET, aeronet.gsfc.nasa.gov) to determine volume size distributions and aerosol optical thickness, and ...

2008-12-01

221

The preliminary success of ALARA implementation in Daya Bay NPP  

International Nuclear Information System (INIS)

Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant procedures, ALARA coordination organization on plant level and for ...

2000-05-01

222

Effect of gamma radiation on electrical and optical properties of (TeO_2)_0_._9 (In_2O_3)_0_._1 thin films  

International Nuclear Information System (INIS)

We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width of band tails of the localized states. The increase of the current with the gamma ...

2011-02-01

223

The Diagnostic Method of Inner Parts of Welded Joints at Nuclear Power Plant  

International Nuclear Information System (INIS)

There is no possibility to check any inner part at real welded joint at nuclear power station (NPS) during operation because any destructive test cannot be used. In practice there is checked surface of weld. There are used four methodical instructions for the check of real welds: 1. The visual inspection, 2. The measurement of hardness, 3. The chemical composition checking and 4. The microstructure replica analysis. It is necessary to know how these information of weld surface are in accordance with characteristics of inner parts of weld. If there is not any difference between surface weld microstructure and internal weld microstructure of experimental weld it is supposed to that there is not any difference in other measured properties of welds. If is changed structural characteristics of microstructure, it is changed also hardness, chemical analysis etc. It was observed that the microstructure of real ...

2010-06-22

224

Measurement of magnetic fields in the Area Metropolitana  

International Nuclear Information System (INIS)

The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which ...

225

Radiation: how safe is safe?  

International Nuclear Information System (INIS)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).

1993-05-01

226

Radiation: how safe is safe  

Energy Technology Data Exchange (ETDEWEB)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).

1993-05-15

227

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

228

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

229

Effect of decrease of molybdenum radiation hardening at high energy proton irradiation  

International Nuclear Information System (INIS)

By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.

1990-05-22

230

Coherent spontaneous radiation from highly bunched electron beams  

International Nuclear Information System (INIS)

Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10"4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques.

1995-08-21

231

Valence mixing in rare earth compounds  

International Nuclear Information System (INIS)

The concepts of ''fast'' and ''slow'' time scale valence measurements are emphasized by a comparison of L/sub III/ absorption and Mossbauer effect measurements on the temperature induced valence change in EuPd/sub 2/Si/sub 2/. Further the authors show how synchrotron radiation based L/sub III/ measurements of the Ce-valence state can be used to demonstrate electronic structure trends under wide changes in chemical environment. The purpose of this paper is to provide an introduction to researchers in the People's Republic of China to the field of mixed valent rate earth compounds. They hope to illustrate some of the basic concepts in this field, how the field is contributing to the overall insight into the chemical physics of solids and finally how synchrotron radiation measurements in particular are playing a key role in this field.

232

Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this ...

1982-01-01

233

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, ...

1997-01-05

234

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, ...

1996-09-01

235

Photoluminescence in large fluence radiation irradiated space silicon solar cells  

Energy Technology Data Exchange (ETDEWEB)

Photoluminescence spectroscopy measurements were carried out for silicon 50{mu}m BSFR space solar cells irradiated with 1MeV electrons with a fluence exceeding 1 x 10{sup 16} e/cm{sup 2} and 10MeV protons with a fluence exceeding 1 x 10{sup 13} p/cm{sup 2}. The results were compared with the previous result performed in a relative low fluence region, and the radiation-induced defects which cause anomalous degradation of the cell performance in such large fluence regions were discussed. As far as we know, this is the first report which presents the PL measurement results at 4.2K of the large fluence radiation irradiated silicon solar cells. (author)

1997-03-01

236

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

237

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

238

Measurement of the ratio of liquid to solid phases in a continuous ingot  

International Nuclear Information System (INIS)

A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous ...

239

Irradiation effects on the electrochemistry and corrosion resistance of stainless steel  

International Nuclear Information System (INIS)

Nickel ion radiation at 500 C was shown to have a strong effect on the surface electrochemistry and intergranular corrosion (IGC) of stainless steel (SS). Measured current densities in a 1 N sulfuric acid solution at room temperature were increased at active-passive, passive, and transpassive potentials. Radiation effects on the current decay behavior and susecptibility to IGC were similar for a fine-grained (FG) S alloy and for a very large-grained (LG) SS. Radiation-induced segregation (RIS) at the surface was believed to promote higher currents at short times, whereas segregation at grain boundaries was responsible for IG attack. Analytical electron microscopy (AEM) measurements revealed chromium and iron depletion plus Ni and silicon enrichment at grain boundaries in irradiated specimens. Si enhanced dissolution at transpassive potentials, whereas Cr depletion did the same at ...

1995-01-01

240

Detached divertor plasmas in JET  

Energy Technology Data Exchange (ETDEWEB)

In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.

1994-07-01

241

Development of fire simulation models for radiative heat transfer and probabilistic risk assessment  

Energy Technology Data Exchange (ETDEWEB)

An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in ...

2008-07-01

242

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may ...

1993-03-01

243

RESOLVING DOPPLER-FACTOR CRISIS IN ACTIVE GALACTIC NUCLEI: NON-STEADY MAGNETIZED OUTFLOWS  

International Nuclear Information System (INIS)

Magnetically driven non-stationary acceleration of jets in active galactic nuclei results in the leading parts of the flow being accelerated to much higher Lorentz factors than in the case of steady-state acceleration with the same parameters. The higher Doppler-boosted parts of the flow may dominate the high-energy emission of blazar jets. We suggest that highly variable GeV and TeV emission in blazars is produced by the faster moving leading edges of highly magnetized non-stationary ejection blobs, while the radio data trace the slower-moving bulk flow. Thus, the radio and gamma-ray emission regions have different, but correlated, Doppler factors. High-energy emission is generated, typically within the optically thick core, in the outer parts of the broad-line emission region, avoiding the radiative drag on the faster parts of the flow. The radio emission should correlate with the ...

2010-10-10

244

Radiation resistance of nylon. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in vacuum, nylon 12 was superior to nylon 6, ...

1983-12-01

245

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, ...

1992-10-25

246

Average neutron resonance parameters and radiative capture cross sections for the isotopes of molybdenum  

International Nuclear Information System (INIS)

The neutron capture cross sections of the stable molybdenum isotopes have been measured with high energy resolution (#DELTA#E/E < approximately 0.2%), between 3 and 90 keV neutron energy, at the 40 m station of ORELA. Average resonance parameters are extracted for s- and p-wave resonances. The s-wave neutron strength function is close to 0.5x10"-"4 for all isotopes, but the p-wave strength function exhibits a well defined peak near A approximately 95. Both s- and p-wave radiative widths decrease markedly as further neutrons are added to the closed shell. The p-wave radiative widths are generally greater than the s-wave widths showing the presence of non-statistical #gamma#-decay mechanisms. Valence neutron theory fails to explain the magnitude of the p- to s-wave radiative width disparity and doorway state processes are invoked. In particular, the data for "9"8Mo appear to violate the usual valence ...

247

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber ...

2007-08-21

248

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

249

The sanitary consequences of chronicle internal contaminations by radionuclides. Advice on the C.E.R.I. report 'study of sanitary effects of exposure to low doses of ionizing radiation to radiation protection purposes ' and I.R.S.N. recommendations; Les consequences sanitaires des contaminations internes chroniques par des radionucleides. Avis sur le rapport CERI 'Etudes des effets sanitaires de l'exposition aux faibles doses de radiations ionisantes a des fins de radioprotection' et recommandations de l'IRSN  

Energy Technology Data Exchange (ETDEWEB)

The report published in 2003 by the European committee on the risk of irradiation (C.E.R.I.) criticizes a part of the ICRP recommendations relative to the internal contaminations.Consequently, I.R.S.N. wishes to supply its own analysis. The present report points the questions linked to the internal contamination and to the difficulties inherent to the risk incurred after chronic exposure.Consequently it does not treat all the problems of the workers and populations radiation protection. (N.C.)

2005-07-01

250

Precision Measurement of the Undulator K Parameter using Spontaneous Radiation  

Energy Technology Data Exchange (ETDEWEB)

Obtaining precise values of the undulator parameter, K, is critical for producing high-gain FEL radiation. At the LCLS [1], where the FEL wavelength reaches down to 1.5 {angstrom}, the relative precision of K must satisfy ({Delta}K/K){sub rms} {approx}< 0.015% over the full length of the undulator. Transverse misalignments, construction errors, radiation damage, and temperature variations all contribute to errors in the mean K values among the undulator segments. It is therefore important to develop some means to measure relative K values, after installation and alignment. We propose a method using the angle-integrated spontaneous radiation spectrum of two nearby undulator segments, and the natural shot-to-shot energy jitter of the electron beam. Simulation of this scheme is presented using both ideal and measured undulator fields. By ...

2007-04-17

251

Characterization of Radiation Instruments at the Summit of Mt. Fuji  

International Nuclear Information System (INIS)

The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically ...

2010-12-01

252

COMPARISON OF NATURAL BACKGROUND DOSE RATES FOR RESIDENTS OF THE AMARGOSA VALLEY, NV, TO THOSE IN LEADVILLE, CO, AND THE STATES OF COLORADO AND NEVADA  

Energy Technology Data Exchange (ETDEWEB)

In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the dose rate in the two identified areas ...

2006-02-24

253

Development of a Computer Program for the Integrated Control of the Fuel Homogeneity Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each ...

2005-11-15

254

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the ...

255

A comparison of cycle-resolved and ensemble-averaged velocity variations in a diesel engine  

Energy Technology Data Exchange (ETDEWEB)

Laser-Doppler anemometry was used to investigate mean flow and turbulence fields in a direct injection diesel engine, motored at speeds of 1500, 2250 and 3000 rev/min. Both cycle-resolved and ensemble-averaged measurements were made in the upper part of the cylinder during the inlet and compression strokes. The cycle-resolved measurements in the inlet stroke are discussed in this paper.

1989-01-01

256

Infrared bleaching of the thermoluminescence of four feldspars  

International Nuclear Information System (INIS)

This paper studies the effect upon the thermoluminescence (TL) signal of four feldspar samples of exposing them to infrared stimulation, as occurs during infrared-stimulated luminescence (IRSL) measurement. Together with pulse annealing measurements these results are used to show which part of the TL signal is removed by exposure to IR and which part is directly related to the IRSL signal that is observed. When the samples are preheated prior to measurement in order to remove any low-temperature (< 200"oC) TL signals, a linear relationship is observed between the amount of TL that is lost and the IRSL light sum that is produced. The IRSL light sum is consistently four times larger than the amount of TL that is lost. Three possible explanations are proposed for this, but no conclusive evidence could be obtained to support any of them. A close similarity is observed in the pulse ...

1995-06-01

257

Polymeric radioactive waste disposal containers: an investigation into the application of polymers vice metals to house low and intermediate level radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The research carried out in Canada in the design of containers for the disposal of radioactive waste has focussed on spent nuclear fuel, even though the quantities of other currently stored radioactive wastes are substantially greater. Research carried out at the Royal Military College of Canada on the effects of mixed fields of radiation on high polymer adhesives and composite materials has shown that some polymers are quite resistant to radiation and could well serve in the fabrication of radioactive waste disposal containers. The purpose of this research was to determine if thermoplastic polymers could be used as superior materials to replace metals in the application of low and intermediate level radioactive waste disposal containers. Polymers have the advantage that they do not corrode like metals. The experimental methods, used in this research, focused on the effects of radiation on the properties of the materials. ...

2001-07-01

258

Theoretical Standard Model Rates of Proton to Neutron Conversions Near Metallic Hydride Surfaces  

CERN Document Server

The process of radiation induced electron capture by protons or deuterons producing new ultra low momentum neutrons and neutrinos may be theoretically described within the standard field theoretical model of electroweak interactions. For protons or deuterons in the neighborhoods of surfaces of condensed matter metallic hydride cathodes, such conversions are determined in part by the collective plasma modes of the participating charged particles, e.g. electrons and protons. The radiation energy required for such low energy nuclear reactions may be supplied by the applied voltage required to push a strong charged current across a metallic hydride surface employed as a cathode within a chemical cell. The electroweak rates of the resulting ultra low momentum neutron production are computed from these considerations.

2006-01-01

259

Behavior of radioactive elements (uranium and thorium) in Bayer process  

International Nuclear Information System (INIS)

It is essential that alumina used for manufacturing electronic devices should contain an extremely low level of alpha-radiation. The principal source of alpha-radiation in alumina is uranium, a minor source being thorium. Uranium in bauxite dissolves into the liquor in the digestion process and is fixed to the red mud as the desilication reaction progresses. A part of uranium remaining in the liquor precipitates together with aluminum hydroxide in the precipitation process. The uranium content of aluminum hydroxide becomes lower as the precipitation velocity per unit surface area of the seed becomes slower. Organic matters in the Bayer liquor has an extremely significant impact on the uranium content of aluminum hydroxide. Aluminum hydroxide free of uranium is obtainable from the liquor that does not contain organic matters.

260

Measurements of transmittance of solar radiation through stearic acid: a latent heat storage material  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the experimental measurements of the transmittivity of commercial grade stearic acid. The effects of temperature and thickness on transmittance have been studied. The study indicates that the effect of temperature on the transmittance of stearic acid in the liquid phase is not significant. However, it is highly dependent on temperature during the solidification process. Because of its low thermal conductivity and high transmittivity, it can be used as a transparent insulating material. (Author)

1999-12-01

261

Gamma absorption determination of concentration in a three-component mixture  

International Nuclear Information System (INIS)

A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.

262

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

263

Turn-key Raman lidar for profiling atmospheric water vapor, clouds, and aerosols at the US Southern Great Plains Climate Study Site  

Energy Technology Data Exchange (ETDEWEB)

There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for ...

1997-12-31

264

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

265

Distributed radiation protection console system  

International Nuclear Information System (INIS)

Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the ...

2004-02-01

266

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and ...

1996-12-01

267

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially ...

268

Assessment of the impact of the greenhouse gas emission and sink scenarios in Finland on radiative forcing and greenhouse effect  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been ...

1996-12-31

269

The influence of a seed crystal on the texture of a bulk YBaCuO specimen  

International Nuclear Information System (INIS)

To investigate the dependence of the local texture of parts of an YBaCuO specimen on the distance of the seed crystal from the position of the part of the specimen, a very good textured YBaCuO specimen was cut into 9 rectangular pieces and into 12 boundary pieces of the cylindric original specimen. From the individual parts of the YBaCuO specimen the texture was measured by neutron diffraction at the Geesthacht reactor with an equal area raster. The grid width was 1 up to 10 deviation from the cylinder axis of the original YBaCuO cylinder and 2 from 10 deviation until 20 deviation. From the sum of the counted neutrons on small circles on the pole sphere the individual values of the distributions of the angular deviations of the c-axes of the crystalline domains from the cylinder axis have been calculated. The mean deviation of the c-axes from the axis of the original cylinder increases from the inner ...

270

Recent increased use of polybutylene terephthalate (PBT) resin in automotive field. Jidosha bun prime ya de kinnen kakudai shimesu PBT jushi  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces marketability and parts application of PBT in the automotive field. Based on the pursuits in automobiles of weight reduction as measures to improve engine performance, drive performance, and fuel consumption, as well as trends of higher class car orientation, market expansion is expected on engineering resins including PBT. Adoption of PBT/polycarbonate (PC)-based alloy resins is on increase for use in external car parts because of the chemical resistance in PBT, low-temperature shock resistance and appearance of PC. Substitution from Nylon resin in connector application is progressing rapidly because of problems in dimensional stability and compound noise. Air bag sensor parts need to be free of maloperation due to contamination and corrosion in metal contacts caused from gases generated from formed parts, hence development of resins of low gas generation ...

1992-06-18

271

Explosives Regulation 2005 under the Explosives Act 2003  

Energy Technology Data Exchange (ETDEWEB)

The object of this Regulation is to provide for those matters that may be, or that are required to be, the subject of regulations under the Explosives Act 2003, The Regulation deals with the following maters: a) a register of authorised and prohibited explosives (Part. 2), b) the classification of explosives (Part. 3), c) matters related to licences under the Explosives Act 2003, including the types of licences, requirements for obtaining licences, certain prescribed licence conditions and certain exemptions from the requirement to have a licences (Part. 4), d) specific control measures relating to the handling of explosives (Part. 5), e) matters of a savings, transitional or administrative nature (Part. 1 and 6). This Regulation refers to the following documents: a) AS 2187, Explosives-storage, transport and use, as published by Standards Australia and in force ...

2005-09-02

272

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies ...

1991-11-01

273

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have yielded 10 mA pulses with ...

1995-08-21

274

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their ...

1995-12-31

275

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

Energy Technology Data Exchange (ETDEWEB)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their feedlines. A flow testing program was completed to ...

1995-10-01

276

Engineering design of cryocondensation pumps for the DIII-D Radiative Divertor Program  

International Nuclear Information System (INIS)

A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase flow regime in the pumps and their ...

1995-10-01

277

Childhood cancer in the surroundings of German nuclear power plants: report of an ongoing epidemiological study; Krebs bei Kindern in der Umgebung von Kernkraftwerken: Bericht zu einer laufenden epidemiologischen Studie  

Energy Technology Data Exchange (ETDEWEB)

Epidemiological studies could not show an association between ionising radiation of nuclear power stations in routine operation and the incidence of childhood cancer, yet. The following report presents a case control study conducted by the German Childhood Cancer Registry since autumn 2003. All children in the study region, who were diagnosed with cancer between 1980 and 2003 at an age below five are included. In the first part of the study we investigate whether children with cancer (cases) lived closer to the respective nuclear power stations compared to random children without cancer (controls). In the second part, for a subgroup of cases and controls we conduct computer assisted telephone interviews regarding confounders possibly associated with the exposure of ionising radiation and childhood cancer. Results are expected by the end of 2006. (orig.)

2006-07-01

278

Microclimatic conditions at the external surface of building envelopes  

Energy Technology Data Exchange (ETDEWEB)

The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat ...

1998-12-31

279

Solid particle receiver experiments: velocity measurements  

Energy Technology Data Exchange (ETDEWEB)

Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.

1984-10-01

280

Solid particle receiver experiments: velocity measurements  

Science.gov (United States)

Laser Doppler velocimetry and other photometric techniques are evaluated for measuring the average particle velocity in an ensemble of free-falling particles. The ability to obtain measurements in the presence of a radiant flux as high as 0.6 MW/m/sup 2/ was part of the evaluation. Optically dissimilar particles with diameters ranging from 0.1 mm to 1 mm were used in the study. Experimental results indicate that ensembles of particles do not behave as single isolated particles. The particle motion is dependent on particle volume fraction, and is quite unstable for falls greater than one meter.

1984-10-01

281

Damping measurements of the magnesium wrought alloys AZ31, AZ61 and AZ80 after indirect and hydrostatic extrusion  

Energy Technology Data Exchange (ETDEWEB)

Magnesium cast parts as well as indirectly and hydrostatically extruded profiles were used in order to investigate the influence of different microstructures on the damping behaviour of magnesium AZ-alloys. Especially, hydrostatic extrusion leads to a significant grain refinement in the extruded profile compared to indirect extrusion. Strain dependent damping measurements were carried out at room temperature using alloys AZ31, AZ61 and AZ80. Damping was determined as the logarithmic decrement of free bending beam vibrations. The results of these measurements after indirect and hydrostatic extrusion are shown and discussed. (orig.)

2005-07-01

282

New results for 5-point functions  

Energy Technology Data Exchange (ETDEWEB)

Bhabha scattering is one of the processes at the ILC where high precision data will be expected. The complete NNLO corrections include radiative loop corrections, with contributions from Feynman diagrams with five external legs. We take these diagrams as an example and discuss several features of the evaluation of pentagon diagrams. The tensor functions are usually reduced to simpler scalar functions. Here we study, as an alternative, the application of Mellin-Barnes representations to 5-point functions. There is no evidence for an improved numerical evaluation of their finite, physical parts. However, the approach gives interesting insights into the treatment of the IR- singularities. (orig.)

2007-12-15

283

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues; Abfaelle mit natuerlicher Radioaktivitaet. Teil 1. Bewertung und Ueberwachung von Materialien und Rueckstaenden  

Energy Technology Data Exchange (ETDEWEB)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far. [German] Die novellierte Strahlenschutzverordnung von 2001 befasst sich auch mit natuerlich vorkommenden radioaktiven Stoffen. Bei ihrer Verwertung oder Beseitigung ergeben sich praktische Fragen, die beachtet werden muessen. Erfahrungen auf diesem Gebiet liegen bisher kaum vor. (orig.)

2003-03-01

284

Laboratory robotics systems at the Savannah River Laboratory  

International Nuclear Information System (INIS)

Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given.

1983-11-16

285

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, the authors are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. They are actively developing improved DC iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. They are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. They are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1988-03-01

286

Electromagnetic wiggler technology development at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As a part of the program at the Lawrence Livermore National Laboratory (LLNL) in induction-linac free-electron laser (IFEL) research, we are conducting a variety of activities addressing the unique requirements imposed on IFEL wiggler systems. We are actively developing improved dc iron-core electromagnetic wiggler designs to attain higher peak fields, greater tunability, and lower random error levels. We are pursuing specialized control systems, such as magnetic-field and beam-position controllers, which can relax requirements on the wiggler itself. We are also pursuing basic studies to establish the effect of radiation on permanent magnets.

1987-01-01

287

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

288

Ionizing radiation alters beta-endorphin-like immunoreactivity in brain but not blood  

Energy Technology Data Exchange (ETDEWEB)

Previous behavioral and pharmacological studies have implicated endorphins in radiation-induced locomotor hyperactivity of the C57BL/6J mouse. However, the endogenous opiate(s) responsible for this behavioral change have not been identified. The present study measured beta-endorphin-like immunoreactivity (beta-END-LI) in brain, blood, and combined brain and pituitary samples from irradiated and sham-irradiated C57BL/6J mice. After radiation exposure, levels of beta-END-LI decreased significantly in the brain. A similar, but not statistically significant, decline was measured in combined brain and pituitary samples. Concentrations of blood beta-END-LI were not changed by irradiation. These radiogenic changes in beta-END-LI are in some ways similar to those observed after other stresses. However, radiation-induced locomotor hyperactivity may be mediated more by alterations of ...

1983-12-01

289

Behavioral effects of exposure to the TEMPO high-power microwave system. Interim report, January-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in ...

1988-03-01

290

State-of-the-art in permeability determination from well log data: Part 1-A comparative study, model development  

Energy Technology Data Exchange (ETDEWEB)

This study discusses and compares, from a practical point of view, three different approaches for permeability determination from logs. These are empirical, statistical, and the recently introduced virtual measurement methods. They respectively make use of empirically determined models, multiple variable regression, and artificial neural networks. All three methods are applied to well log data from a heterogeneous formation and the results are compared with core permeability, which is considered to be the standard. In this first part of the paper we present only the model development phase in which we are testing the capability of each method to match the presented data. Based on this, the best two methods are to be analyzed in terms of prediction performance in the second part of this paper.

1995-12-31

291

Selected hydrologic data from the northern part of the Hueco Bolson, New Mexico and Texas  

Science.gov (United States)

Hydrologic data were collected in early 1985 from the northern part of the Hueco Bolson in Dona Ana County, New Mexico, and El Paso County, Texas, and in adjacent areas in the Tularosa Basin in New Mexico. Water-level measurements made in 50 wells are presented in this report. Information is also presented on groundwater withdrawals from the Hueco Bolson by El Paso and Ciudad Juarez municipal wells, by industrial and military wells, and by wells in the Chaparral, New Mexico, area that have been used for both irrigation and municipal purposes. Lithologic logs and geophysical logs are included for four test wells that were drilled as part of this project during August and September 1985. (USGS)

1985-01-01

292

Radiological assessment of terrestrial environment of facilities of G.I.P. CYCERON from Caen - year 2003; Bilan radiologique de l'environnement terrestre des installations du GIP CYCERON de Caen - annee 2003  

Energy Technology Data Exchange (ETDEWEB)

Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...

2004-07-01

293

Feasibility of optical sensing for robotics in highly radioactive environments  

International Nuclear Information System (INIS)

The application of robotics for repair, refurbishing or dismantling of nuclear installations implies eventually severe radiation resistance requirements on embarked components and subsystems. This is particularly critical when optical sensing is considered. Optoelectronic components and optical fibers are indeed quite sensitive to radiation, and without special design are rapidly out-of-operation in such an environment. This paper reports the results of a series of #gamma# irradiation experiments on such devices, and identify their behavior under radiation. Test results show that carefully selected optical fibers can keep their radiation induced attenuation lower than 0.3 dB/m even up to a total dose of 10 MGy. Temperature annealing can even lower this attenuation down to 0.1 dB/m. On the other hand, commercially available light emitting diodes and photodiodes present attenuations figures up to 15 dB, ...

1992-10-25

294

Tritium monitor with improved gamma-ray discrimination  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

1985-01-01

295

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

296

FFTF shield and gamma ray measurements  

Energy Technology Data Exchange (ETDEWEB)

Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.

1984-08-01

297

Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities  

Energy Technology Data Exchange (ETDEWEB)

The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.

1999-01-01

298

Si-JFET devices and related noise behavior under irradiation  

Energy Technology Data Exchange (ETDEWEB)

Monolithic N-channel junction field effect transistors (NJFETs) dc characteristics, small signal parameters and noise have been studied from 300 K down to cryogenic temperatures before and after irradiation with {sup 60}Co {gamma}-rays and fast neutrons (1 MeV). Radiation induced effects on dc parameters and noise are reviewed. Noise spectral density measurements performed at various temperatures have shown that the radiation induces a noise increase which is temperature and frequency dependent. (orig.). 14 refs.

1998-02-01

299

Radiolysis of neutron irradiated lithium solutions  

International Nuclear Information System (INIS)

In the Aqueous Self-Cooled Blanket (ASCB) concept, an aqueous "6Li solution in a metallic structure is used as a shielding-breeding blanket for fusion reactors. The experimental results of this study indicate that the radiolytic gas production in an ASCB will be proportional to the absorbed radiation energy. The observed radiation chemical yields allow the preliminary estimation of the radiolysis effects for a specific ASCB design. Contrary to the theoretical predictions, the use of hydrogen as a cover gas at up to 1 MPa had no measurable effect on the radiolytic gas production. Probably it will thus not be possible to suppress the radiolytic decomposition of a low-pressure ASCB by the addition of hydrogen. Catalytic recombination will be required. (orig.).

300

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

301

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

302

Photon angular distribution of radiative electron capture into the M shell of He-like uranium ions at 110-140 MeV/u  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the photon angular distribution of Radiative Electron Capture into the M shell have been performed with He-like uranium ions in the range 110-140 MeV/u. In addition, L REC was studied at a projectile energy of 140 MeV/u. In both cases, the experimental data show an asymmetry around 90 and agree well with a fully relativistic theory. (orig.) 15 refs.

1995-10-01

303

Parameterization of GCM subgrid nonprecipitating cumulus and stratocumulus clouds using stochastic/phenomenological methods. Annual technical progress report, 1 December 1992--30 November 1993  

Energy Technology Data Exchange (ETDEWEB)

This document is a progress report to the USDOE Atmospheric Radiation and Measurement Program (ARM). The overall project goal is to relate subgrid-cumulus-cloud formation, coverage, and population characteristics to statistical properties of surface-layer air, which in turn are modulated by heterogeneous land-usage within GCM-grid-box-size regions. The motivation is to improve the understanding and prediction of climate change by more accurately describing radiative and cloud processes.

1993-08-27

304

Palliation of radiation-related mucositis  

Energy Technology Data Exchange (ETDEWEB)

Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.

1990-01-01

305

Measurement of stress in materials using chromium K/sub. beta. / radiation  

Energy Technology Data Exchange (ETDEWEB)

Bragg peaks obtained in X-ray stress analysis studies are often asymmetric. The use of K/sub ..beta../ rather than K/sub ..cap alpha../ radiation simplifies the problem of peak location, as only one Bragg peak needs to be analysed. It is shown, however, that the common practice of fitting a parabola to the top 15% of the data in a Bragg peak in order to determine the peak position, when the fitted region is asymmetric, can lead to large errors in the calculated stress. Asymmetric pseudo-Lorentzian functions have been found to provide the most satisfactory fits.

1983-01-01

306

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

307

ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD  

Energy Technology Data Exchange (ETDEWEB)

A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.

1983-01-01

308

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

309

815nm radiation from germicidal lamps  

International Nuclear Information System (INIS)

An investigation of the intensity of electromagnetic radiation at a wavelength of 185nm emitted by a General Electric mercury discharge, germicidal lamp is described. From the measurement of the transmission of light as a function of wavelength from 185nm to 360nm, it was concluded that this type of germicidal lamp does not produce any biological or chemical effects through the 185nm line; the intensity of the 185nm line transmitted by the lamp was less than 0.1% of that for the 254nm line. Consequently, there was no discernable ozone production. (U.K.).

310

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

311

FFTF reactor-characterization program: gamma-ray measurements and shield characterization  

Science.gov (United States)

A series of experiments is to be made during the acceptance test program of the Fast Flux Test Facility (FFTF) to measure the gamma ray characteristics of the Fast Test Reactor (FTR) and to establish the performance characteristics of the reactor shield. These measurements are a part of the FFTF Reactor Characterization Program (RCP). Detailed plans have been developed for these experiments. During the initial phase of the Characteristics Program, which will be carried out in the In-Reactor Thimble (IRT), both active and passive measurement methods will be employed to obtain as much information concerning the gamma ray environment as is practical. More limited active gamma ray measurements also will be made in the Vibration Open Test Assembly (VOTA).

312

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-15

313

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-01

314

Assessing radiologic risk for population due to human activities  

International Nuclear Information System (INIS)

The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well as their input rate. ...

2002-09-06

315

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

316

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

317

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a ...

2008-01-01

318

Radiation processed composite materials of wood and elastic polyester resins  

International Nuclear Information System (INIS)

The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of wood composite ...

1982-09-19

319

Radiation hardening in neutron-irradiated polycrystalline copper: Barrier strength of defect clusters  

International Nuclear Information System (INIS)

Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).

1989-12-04

320

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

321

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

322

Heat loss from an open cavity  

Energy Technology Data Exchange (ETDEWEB)

Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating ...

1995-12-01

323

Electron scattering from atoms in the presence of a laser field. II  

Science.gov (United States)

In the first paper of this series a formal theory of atomic scattering of electrons in the presence of an intense electromagnetic field was given. Cross sections, near the forward direction, between atomic states (modified by the laser) were obtained. However, it was assumed that the atom could not emit spontaneous radiation. In this paper the effect of spontaneous radiation is included, and it is shown that in most cases the measured cross section will be a weighted average of the two different cross sections starting from the two different initial states which are those atomic states resonantly linked by the laser. The Born approximation for the scattering is obtained, and it is shown that for the simplest description of the spontaneous radiation field the effect of the laser on the cross sections is simply to multiply them by a factor which depends upon the laser detuning. (AIP)

1976-10-01

324

Assessment and control of fetal exposure  

Energy Technology Data Exchange (ETDEWEB)

The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, ...

1991-10-01

325

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

326

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

327

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

328
329

Destruction of organic chemicals in Hanford HLW tanks by radiolytic and chemical aging  

International Nuclear Information System (INIS)

The underground storage tanks at the Hanford Complex contain mixed wastes generated over many years from plutonium production and recovery processes. The chemical changes of the organic materials used in the extraction processes and disposed to the tanks have a direct bearing on several specific safety issues, including potential energy releases from these tanks. This paper will give details of a study that is directed towards elucidating thermal and radiological decomposition mechanisms and products of the organic contents of the tanks. The study is being conducted in two parts. The first part, an aging study, will determine kinetics and products of the degradation of a simulated waste subjected to #gamma#-radiation from an external source. Although the simulant will not contain radioactive elements, it will contain other representative inorganic compounds and the primary organic compounds thought to have been disposed to ...

1994-08-21

330

Joint Thesaurus. Part I (A-L) + Part II (M-Z)  

International Nuclear Information System (INIS)

This is the 1st revision of the INIS/ETDE Joint Thesaurus. It contains 20 953 valid descriptors and 8 600 forbidden terms. It was last updated in December 2003. The Joint Thesaurus contains the controlled terminology for indexing all information within the subject scope of both INIS (International Nuclear Information System) and ETDE (Energy Technology Data Exchange) information systems. The terminology is intended for use in subject description for input or retrieval of information in those systems. The thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language It is also a controlled and dynamic vocabulary of semantically and generically related terms which covers a specific domain of knowledge. The domain of knowledge covered by this Thesaurus includes physics (in particular, plasma physics, atomic and molecular physics, and especially nuclear and high-energy physics), chemistry, ...

1998-05-01

331

Effective equivalent dose and radiation risk in radionuclide diagnostics estimated in patients of the Nuclear Medicine Department of the Medical Academy 'Carl Gustav Carus' Dresden  

International Nuclear Information System (INIS)

7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x Sv, the mean somatic risk 1.7 x 10"-"5 ...

1986-01-01

332

Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis  

International Nuclear Information System (INIS)

As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the ...

2009-07-01

333

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...

2004-10-13

334

The combination therapy with hepatic arterial infusion chemotherapy and radiation therapy for unresected intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

The outcome was retrospectively examined and prognostic factors were discussed for arterial chemo-infusion therapy (ACT) through an implanted reservoir system and radiation therapy (RT) in patients with unresectable intrahepatic cholangiocarcinoma (CCC). ACT plus RT were conducted to 25 patients (mean age 61.7 y, M/F 12/13, stage III-IVB) during 10 years from 1996 to 2005 with various regimens of cisplatin (CDDP), 5- fluorouracil (FU), epirubicin (FARM), mitomycin C (MMC) plus 39-50 Gy of radiation in a fractionated manner partly involving internal RT (2 cases, 15 Gy) and RT for metastatic bone (1, 25 Gy). The survival rates at 1, 2 and 3 years after ACT+RT were respectively 52.5, 43.7 and 28.1%; total efficacy (PR) was 36% (9/25) at 6 months; and significantly good prognostic factors were found to be female and absence of metastasis remote and/or lymphatic around artery. Authors concluded that ACT+RT was a meaningful ...

2007-11-01

335

The Herschel revolution: unveiling the morphology of the high mass star formation sites N44 and N63 in the LMC  

CERN Document Server

We study the structure of the medium surrounding sites of high-mass star formation to determine the interrelation between the HII regions and the environment from which they were formed. The density distribution of the surroundings is key in determining how the radiation of the newly formed stars interacts with the surrounds in a way that allows it to be used as a star formation tracer. We present new Herschel/SPIRE 250, 350 and 500 mum data of LHA 120-N44 and LHA 120-N63 in the LMC. We construct average spectral energy distributions (SEDs) for annuli centered on the IR bright part of the star formation sites. The annuli cover ~10-~100 pc. We use a phenomenological dust model to fit these SEDs to derive the dust column densities, characterise the incident radiation field and the abundance of polycyclic aromatic hydrocarbon molecules. We see a factor 5 decrease in the radiation field energy density as a ...

2010-01-01

336

Status of the MORSE multigroup Monte Carlo radiation transport code  

Energy Technology Data Exchange (ETDEWEB)

There are two versions of the MORSE multigroup Monte Carlo radiation transport computer code system at Oak Ridge National Laboratory. MORSE-CGA is the most well-known and has undergone extensive use for many years. MORSE-SGC was originally developed in about 1980 in order to restructure the cross-section handling and thereby save storage. However, with the advent of new computer systems having much larger storage capacity, that aspect of SGC has become unnecessary. Both versions use data from multigroup cross-section libraries, although in somewhat different formats. MORSE-SGC is the version of MORSE that is part of the SCALE system, but it can also be run stand-alone. Both CGA and SGC use the Multiple Array System (MARS) geometry package. In the last six months the main focus of the work on these two versions has been on making them operational on workstations, in particular, the IBM RISC 6000 family. A new version of SCALE for workstations is ...

1993-06-01

337

Opto-acoustic recanilization delivery system  

Energy Technology Data Exchange (ETDEWEB)

Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An ...

2002-01-01

338

Additive effects common to radiation grafting and wood plastic composite formation  

Energy Technology Data Exchange (ETDEWEB)

A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium ...

1996-08-01

339

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, ...

2009-05-26

340

Remote Sensing and In-Situ Observations of Arctic Mixed-Phase and Cirrus Clouds Acquired During Mixed-Phase Arctic Cloud Experiment: Atmospheric Radiation Measurement Uninhabited Aerospace Vehicle Participation  

Energy Technology Data Exchange (ETDEWEB)

The Atmospheric Radiation Monitor (ARM) uninhabited aerospace vehicle (UAV) program aims to develop measurement techniques and instruments suitable for a new class of high altitude, long endurance UAVs while supporting the climate community with valuable data sets. Using the Scaled Composites Proteus aircraft, ARM UAV participated in Mixed-Phase Arctic Cloud Experiment (M-PACE), obtaining unique data to help understand the interaction of clouds with solar and infrared radiation. Many measurements obtained using the Proteus were coincident with in-situ observations made by the UND Citation. Data from M-PACE are needed to understand interactions between clouds, the atmosphere and ocean in the Arctic, critical interactions given large-scale models suggest enhanced warming compared to lower latitudes is occurring.

2005-03-18

341

Mercury-free fluorescent lighting  

Energy Technology Data Exchange (ETDEWEB)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...

1996-05-01

342

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the ...

1991-06-01

343

Radionuclide Air Emissions Report for the Hanford Site Calendar year 1998  

Energy Technology Data Exchange (ETDEWEB)

This report documents radionuclide air emissions from the Hanford Site in I998 and the resulting effective dose equivalent to the maximally exposed individual (MEI) member of the public. The report has been prepared in accordance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (40 CFR SI), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,'' and with the Washington Administrative Code Chapter 246-247, Radiation Protection--Air Emissions. The federal regulations in 40 CFR 61, Subpart H; require the measurement and reporting of radionuclides emitted from Department of Energy facilities and the resulting offsite dose from those emissions. A standard of 10 mrem/yr effective dose equivalent (EDE) is imposed on them. The EDE ...

1999-06-15

344

Environmental survey of former royal artillery range hebrides  

International Nuclear Information System (INIS)

Full text of publication follows: The former UK Royal Artillery Range, Hebrides had been used to store and use radioactive miss distance indicators (R.A.M.D.I.) in the testing of Rapier missiles. As part of the testing, missiles were fired out to sea between about 1970 and 1981. Concerns were expressed in early 2004 by some within the local community that there was an unknown, ongoing hazard to them from the impact on the local environment resulting from the use radioactive material in these trials. Accordingly Defence Science and Technology Laboratory, Environmental Science Department (D.s.t.l. E.S.D.) were tasked by the Ministry of Defence to carry out an Environmental Survey of the former Royal Artillery Range, Hebrides and surrounding areas; the environmental survey was carried between the dates of 18 28 May 2004. D.s.t.l. E.S.D. environmental survey focussed upon buildings and areas within and immediately adjacent to the Range Compound, launch areas, and the ...

2006-05-15

345

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work ...

2006-01-01

346

Temperature-dependent properties of semiconductor quantum dots in coherent regime; Temperaturabhaengige Eigenschaften einzelner Halbleiter-Quantenpunkte im Kohaerenten Regime  

Energy Technology Data Exchange (ETDEWEB)

Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the relevant levels can be ...

2009-10-15

347

On the Role of Convection and Turbulence for Tropospheric Ozone and its Precursors  

International Nuclear Information System (INIS)

The aim of the work in this thesis is to investigate the convective and diffusive transport in the TM chemistry transport model, and to investigate some aspects of the consequences for NOx. The large inaccuracy and uncertainty in the description of processes like convection and turbulent diffusion, the strong dependence of the radiative forcing of ozone on its vertical distribution, and the strong dependence of the ozone production on the distribution of NOx, are the main motivation. The availability of the ERA-40 data, where convective data and vertical diffusion coefficients are archived, allows a study of the effect of different convective mass flux sets, and different vertical diffusion coefficients on the model-simulated distribution of tracers. In this thesis the following questions are addressed : (1) How large is the sensitivity of the (model simulated) distribution of ozone and nitrogen oxides on (the) convection (parameterisation)?; (2) What requirements ...

348

Radiant emittance of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...

1994-12-31

349

Thermoelectrically cooled water trap  

Energy Technology Data Exchange (ETDEWEB)

A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.

2006-02-21

350

Measurements of environmental policy for air pollution abatement. Umweltpolitische Massnahmen zur Luftreinhaltung; Kosten-Nutzen-Analyse  

Energy Technology Data Exchange (ETDEWEB)

The first part of the study goes into the determination of efficient strategies for the reduction of air pollutants. The developed method is not only derived theoretically but is tested with the concrete example of emissions sources of a German state. The second part goes into the question what the government can do in order to attain that air pollution abatement measures recognized as being efficient will be put into practice. As market economy mechanisms have advantages over central state planning in the allocation of economic resources the question arises if not also for environmental protection market economy tools may contribute to an improvement of the efficiency of air pollution abatement. Therefore the suitability of different tools of environmental policy for the realization of efficient air pollution abatement is investigated and evaluated. This is again not done abstractly but with existing emission sources. ...

1993-01-01

351

Formation of particles in combustion of biofuels  

International Nuclear Information System (INIS)

Biomass combustion is an important part in a sustainable energy system, but as well a source of submicron (particles < 1 #mu#m) particles in the air. Consequently, to obtain a good air quality together with increased biomass combustion there is a need for a better understanding of particle formation. This work is a part of a larger project about formation and emissions of particles from biofuel combustion. The report includes the work performed in the project during the year 2004. The aim of the project is to describe the release of inorganic components, which cause particle emissions, during combustion of single fuel particles of biofuel, e.g. wood pellets. The work is carried out by emission measurements, systematic combustion experiments and modelling work. The results are expected to contribute to the understanding of which parameters that influence the formation of fine particles and thus gain a better insight into ...

352

The Argonne boundary layer experiments facility : using minisodars to complement a wind profiler network.  

Energy Technology Data Exchange (ETDEWEB)

The Argonne Boundary Layer Experiments (ABLE) facility, located in south central Kansas, east of Wichita, is devoted primarily to investigations of and within the planetary boundary layer (PBL), including the dynamics of the mixed layer during both day and night; effects of varying land use and land form; the interactive role of precipitation, runoff, and soil moisture; storm development; and energy budgets on scales of 10 to 100 km. Located entirely within the Walnut River watershed, ABLE provides intense measurements within the northeast quadrant (Fig. 1) of the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) of the Atmospheric Radiation Measurement (ARM) Program (Stokes and Schwarz, 1994). By combining the continuous measurements of ABLE with ancillary continuous measurements of, for example, the ARM and the Global Energy Water cycle Experiment ...

1998-06-05

353

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to ...

2003-11-01

354

Ultraviolet-B Phototoxicity and Hypothetical Photomelanomagenesis: Intraocular and Crystalline Lens Photoprotection  

British Library Electronic Table of Contents (United Kingdom)

Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...

2010-01-01

355

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

356

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is ...

1981-01-01

357

Measurements to be taken after a nuclear accident in order to limit the uptake of radionuclides from the soil by nutrition crops  

International Nuclear Information System (INIS)

By the department Radio-ecology of the Laboratory for Radiation Research, in the period 1981 up to 1989 inclusive, the transfer has been studied, from soil to plant, of a number of important activation and fission products, originating in the nuclear-power production in nuclear power plants. The purpose of this study was twofold: on the one side the quantification of this transfer for various agrarian systems and on the other side to find out in how far, after an accidental contamination, certain agriculture activities can influence essentially the transfer and subsequently the radiation burden for the population. Emphasis lay, the last years, in particular upon this second aspect. The results of this study form essential basic data for diffusion models for radioactive materials which, in turn, are important in estimating the effects of measures. (author). 6 refs.; 4 figs.

358

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

359

Processing method and processing facility for carbon steel parts in nuclear power plant  

International Nuclear Information System (INIS)

In a closed circuit formed by bypassing pipelines connected to carbon steel parts, low oxygen coolants pass there through during operation. A solution containing ions of metals more noble than iron are circulated to bring the solution into contact with the carbon steel surface of the inner wall of the parts to form a deposition membrane of the metal more noble than iron on the surface to prevent acceleration of corrosion of the carbon steel parts due to low oxygen coolants. The solution containing ions of metals more noble than iron is a solution of palladium nitrate containing ions of platinum elements. This operation is conducted under a temperature condition of from 50degC to 150degC. In addition, the metal ion concentration of the solution circulating in the closed circuit is measured, it is compared with metal ion concentration previously determined, and the results are feed back to a means for ...

1996-11-27

360

Photochemical processes and ozone production in Finnish conditions  

Energy Technology Data Exchange (ETDEWEB)

Photochemical ozone production is observed in March-September. Highest ozone concentrations and production efficiencies are observed in spring in the northern parts and in summer in the southern parts of the country. VOC concentrations are relatively low compared to continental areas in general. During the growing season a substantial part of the total reactive mass of VOCs is of biogenic origin. Large forest areas absorb ozone substantially, decreasing the ambient ozone concentrations in central and northern parts of Finland where long-range transport of ozone is relatively important compared to local production. The aim of the work conducted at Finnish Meteorological Institute has been to characterise concentrations of photochemically active species in the boundary layer and their photochemical formation and deposition including the effects on vegetation. Also interactions between the boundary layer ...

1996-12-31

361

Measurement of W{sup {+-}} boson mass at LEP by means of DELPHI detector; Mesure de la masse des bosons W{sup {+-}} au LEP a l`aide du detecteur DELPHI  

Energy Technology Data Exchange (ETDEWEB)

The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.

1998-05-25

362

Different techniques for measuring radon concentration in a spa environment  

International Nuclear Information System (INIS)

In the context of radiation protection for both workers and the population in general, natural sources of radiation, and in particular radon gas and its short-life decay products assume great importance. In particular, workers in thermal spas can easily be exposed to a level of radon radiation and its decay products comparable to those in uranium mines, though often these workers are unaware of the danger. The main source of radon in thermal baths is the thermal water itself, coming as it often does from deep springs, and this can produce high radon concentrations which are left in those areas in which therapy is carried out. Another factor which cannot be overlooked is the radioactive content of thermal mud, often matured for long periods by contact with thermal water. Thermal cures, though varying slightly from site to site, consist principally of mud cures, hydro-therapy and inhalation in various forms. Both health ...

2002-10-08

363

First detection of lamella-gyroid-cylinder phase transition of neat polyethylene-poly(ethylene oxide) diblock copolymers on the basis of synchrotron WAXD/SAXS and infrared/Raman spectral measurements  

International Nuclear Information System (INIS)

The phase transition behaviour of polyethylene-b-poly(ethylene oxide) (PE-b-PEO) diblock copolymer with relatively short chain lengths has been studied on the basis of temperature dependent infrared and Raman spectral measurements and synchrotron WAXD/SAXS simultaneous measurements, from which the concrete structural changes were deduced successfully from the various levels of molecular chain conformation, chain packing mode and higher-order structure. The higher-order structure has been found to transform between lamella, perforated lamella, gyroid, cylinder and sphere structures. The inner structural changes occurring in the polyethylene and poly(ethylene oxide) parts have been related with these morphological changes. The morphological transition from lamella to gyroid occurs with keeping the crystalline state of polyethylene parts. This apparently curious transition can be interpreted reasonably by ...

2009-08-01

364

Compressed-shell integrity measurements in spherical implosion experiments  

International Nuclear Information System (INIS)

The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations ...

2001-06-01

365

Cold SQUIDs and hot samples  

Energy Technology Data Exchange (ETDEWEB)

Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise ...

1997-05-01

366

Dosimetry measurements of x-ray and neutron radiation levels near the shuttle and end beam dump at the advanced test accelerator: Beam Research Program  

International Nuclear Information System (INIS)

Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...

367

[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].  

Science.gov (United States)

Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295

1986-01-01

368

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

369

Human climatic comfort within enclosing walls with varying strengths of infrared radiation reflection  

Energy Technology Data Exchange (ETDEWEB)

An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% saving in heating ...

1985-06-01

370

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal ...

1981-10-01

371

Daytime Raman lidar measurements of water vapor during the ARM 1997 water vapor intensive observation period  

Energy Technology Data Exchange (ETDEWEB)

Because of the importance of water vapor, the ARM program initiated a series of three intensive operating periods (IOPs) at its CART (Cloud And Radiation Testbed) site. The goal of these IOPs is to improve and validate the state-of-the-art capabilities in measuring water vapor. To date, two of the planned three IOPs have occurred: the first was in September of 1996, with an emphasis on the lowest kilometer, while the second was conducted from September--October 1997 with a focus on both the upper troposphere and lowest kilometer. These IOPs provided an excellent opportunity to compare measurements from other systems with those made by the CART Raman lidar. This paper addresses primarily the daytime water vapor measurements made by the lidar system during the second of these IOPs.

1998-04-01

372

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

373

A high sensitivity two-color interferometer for pulsed power plasmas  

International Nuclear Information System (INIS)

A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are ...

374

Thermal modelling of underground coal fires in Northern China  

Energy Technology Data Exchange (ETDEWEB)

The thesis describes work undertaken as part of a larger remote sensing based project which aims to detect, measure and monitor coal fires in two test areas in northern China. The first main topic addressed in this thesis is the detection of fires using several different thermal remote sensing data sets. The synergistic use of the different data sets is emphasised. The second major part of the thesis deals with thermal modelling of the coal fires. Three different models are developed, which allow a fire's depth, temperature, extent, total heat output and rate of movement to be determined. The models are tested both in the laboratory and using various field data sets. A model based on the assumption that the fire is a point heat source and that the temperature distribution around it is spherically symmetrical is shown to be the most effective. A simpler, one-dimensional coal fire model and a model based on the ...

1998-07-01

375

The dosimetric verification of a pencil beam based treatment planning system  

International Nuclear Information System (INIS)

A new three-dimensional treatment planning system (TPS) based on convolution/superposition algorithms (TMS-Radix from HELAX AB, Uppsala, Sweden) was recently installed at the University Hospital in Lund. The purpose of the present study was to design a quality assurance and acceptance testing programme to meet the specific characteristics of this convolution model. The model is based on parametrization of a non-measurable quantity - the polyenergetic pencil beam. However, the verification of the treatment planning model is still dependent on numerous comparisons of measured depth-doses and dose profiles. The test programme was divided in two basic parts: (i) model implementation and beam data consistency and (ii) model performance and limitations in special situations. The first part was scheduled for all photon beam qualities available before they could be used for clinical treatment planning. The ...

376

Overview of the programme forseen for the potential site Oberbauenstock (Community Bauen UR)  

International Nuclear Information System (INIS)

On 30th September 1985, the Federal Government licensed site suitability investigations in three areas with a view to disposal of low-and intermediate-level radioactive waste. This report gives a summary overview of the corresponding research programme at the potential site Oberbauenstock. The first part of the report begins with some comments on the concept of radioactive waste disposal and on some basic aspects of site-specific exploration and investigation. The governmental decision of 30th September and Nagra's two-phase investigation concept are then briefly considered. To close, the objectives of investigation phase I are outlined and possible results are briefly discussed. The research programme developed for investigation of the potential site at Oberbauenstock is presented in the second part of the report. Besides geological and hydrogeological investigations at the surface, the programme mainly comprises investigations and ...

1985-09-01

377

Study on laminar burning velocity of premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames; CH{sub 4}/O{sub 2}/CO{sub 2} yokongo kaen no soryu nensho sokudo ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

Experimental and numerical investigations were performed for the laminar burning velocity and the flame structure of laminar premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames. Measurements of the laminar burning velocity were conducted by using a flame cone angle method for a circular nozzle burner. Numerical simulation was performed using one-dimensional plane flame code including radiation heat loss with an optically thin model. It was shown that the laminar burning velocity decrease with CO{sub 2} addition even though the adiabatic flame temperature is the same as that for CH{sub 4}/Air flames. The radiation heat loss is significant for the CH{sub 4}/O{sub 2}/CO{sub 2}, flames, and the flame temperature and laminar burning velocity decreases when the radiation heat loss is considered. Effects of thermal properties, radiation, and chemical reaction on the determination of the laminar ...

1999-07-25

378

Microwave radiation effects on the thermally driven oxidase of erythrocytes  

Energy Technology Data Exchange (ETDEWEB)

Sheep red blood cells (SRBCs) were labelled with a concanavalin A-luminol-bovine serum albumin conjugate specific for the transmembrane anion transport protein (Band 3) and exposed to 2450-MHz continuous-wave microwave radiation at an average specific absorption rate of 91W/kg for 10 min. The temperature was held constant at 25, 37, 40, 42, or 45C with an airflow heat-exchange system. Following exposure to microwave or air heating, the decrease in residual base-activated chemiluminescence (CL) of the SRBCs was measured as an indication of infield oxidase activity. Air heating resulted in a significant decrease in residual CL at temperatures above 37C (74% decrease at 45C). Microwave radiation inhibited the decline in residual CL above 37C. At 45C the inhibition was 40%. The results suggest microwave radiation either reversibly altered the thermodynamics of oxygen binding to haemoglobin or failed to ...

1986-01-01

379

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging. 2  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from simultaneous aging tests, while the lifetime of other ...

1994-01-01

380

Gene expression analysis after low dose ionising radiation exposure of the developing organism  

International Nuclear Information System (INIS)

Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two main stages of ...

2007-09-01

381

Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data  

Science.gov (United States)

The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on several hours (2-10) an appropriate maximum of ...

2010-01-01

382

Shot-noise-limited measurement of sub-parts-per-trillion birefringence phase shift in a high-finesse cavity  

International Nuclear Information System (INIS)

We report on a promising approach to high-sensitivity anisotropy measurements using a high-finesse cavity locked by optical feedback to a diode laser. We provide a simple and effective way to decouple the weak anisotropy of interest from the inherent mirror's birefringence whose drift may be identified as the key limiting parameter in cavity-based techniques. We demonstrate a shot-noise-limited phase shift resolution previously inaccessible in an optical cavity, readily achieving the state-of-the-art level of 3x10"-"1"3 rad.

2010-09-01

383

Methods and instruments for nondestructive testing of the anisotropy of the magnetic properties of ferromagnetic sheet materials (review)  

Energy Technology Data Exchange (ETDEWEB)

This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.

1995-04-01

384

Ergodic properties of Poissonian ID processes  

CERN Document Server

We show that a stationary IDp process (i.e., an infinitely divisible stationary process without Gaussian part) can be written as the independent sum of four stationary IDp processes, each of them belonging to a different class characterized by its L\\'{e}vy measure. The ergodic properties of each class are, respectively, nonergodicity, weak mixing, mixing of all order and Bernoullicity. To obtain these results, we use the representation of an IDp process as an integral with respect to a Poisson measure, which, more generally, has led us to study basic ergodic properties of these objects.

2007-01-01

385

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the ...

1979-01-01

386

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product ...

387

Turbo expanders for separation of gas mixtures by partial condensation  

International Nuclear Information System (INIS)

Thermodynamic consideration and process calculations at equilibrium conditions showed that processes for separating gas mixtures by partial condensation at low temperatures using turboexpanders have got less energy losses than processes with quasi isobar partial condensation. Compared to the low-pressure parts of condensing steam turbines in turboexpanders less erosion problems are to expected for such separating processes. Separation of liquid in the machine, however, is more difficult withouf additional measures. (orig.).

388

Organisation and training of coke oven management  

Energy Technology Data Exchange (ETDEWEB)

Japan`s coke industry was developed as the basic part for iron and steel industry. The paper addresses two factors as a characteristic of Japan-unique management. One topic is operation management and equipment management of coke factory; the second topic is human resource training in a company that lies under each management. The concepts and actual methods of these topics are introduced by showing examples. The paper discusses the improvement of the working environment and measures for future employment caused by the aging problem in Japan. 5 figs.

1994-12-31

389

Monoclonal antibody imaging in malignant and benign gastrointestinal diseases  

International Nuclear Information System (INIS)

The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).

390

Measurement of the electrical resistivity of the lithium isotopes at low temperatures  

Energy Technology Data Exchange (ETDEWEB)

The electrical resistivity at low temperatures (T = 10 to 90 K) of the lithium isotopes /sup 6/Li and /sup 7/Li and of an isotopic mixture /sup 7 +6/Li has been studied. The specimens contained a small amount of chemical impurities. An appreciable difference was observed in the temperature dependence of the resistivity produced both by deformation of the phonon spectrum, related to the change in isotopic composition, and by the presence of chemical impurities making the nonequilibrium part of the electron distribution function more isotropic.

1982-03-01

391

Deep drawing and impact extrusion of magnesium alloys at room temperature  

Energy Technology Data Exchange (ETDEWEB)

Magnesium alloys and composites are potentially highly attractive materials for lightweight design in the automotive industry - if common forming technologies, i.e., deep drawing and cold extrusion, are applicable to them; so far, this is seldom the case. The authors have tested some candidate Mg alloys and discuss the results of their measurements in detail. The Figure shows a typical workpiece part obtained by a deep-drawing technique. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

2003-04-01

392

Comparison of calculated and measured irradiated wire data for HEU and mixed HEU/LEU cores in the ORR (Oak Ridge Research Reactor)  

Energy Technology Data Exchange (ETDEWEB)

Low power wire activations are being performed in the Oak Ridge Research Reactor (ORR) as part of the whole-core LEU demonstration experiments. Calculations of the demonstration cores, including simulation of the wire activations, are being performed at Argonne National Laboratory (ANL). This paper presents the results of comparisons for 293 wires from five cores and shows that, on the average, the integrated activities agree within 6%.

1986-01-01

393

Automated remote positioning and examination of FFTF reactor power characterization dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.

1981-05-04

394

Assessment of audible noise from high voltage transmission lines and a high voltage transformer station  

Energy Technology Data Exchange (ETDEWEB)

The study of audible noise from high voltage transmission lines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmission lines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmission lines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona sound spectra have ...

1986-11-01

395

Activity report 2001; Rapport annuel d'activite 2001  

Energy Technology Data Exchange (ETDEWEB)

The DED, Department of the Wastes Studies, part of the Direction of the Nuclear Energy of the CEA, regroups knowledge in the domain of the chemistry, the biochemistry, the process measures and simulation engineering applied to the radioactive wastes management. This annual report presents for the year 2001 the missions, the organization, the scientific collaborations, the research programs and the publications of the Department. (A.L.B.)

2001-07-01

396

Absolute fission rates in the FFTF  

Energy Technology Data Exchange (ETDEWEB)

The part of the FFTF Reactor Characterization Program reported in this paper is a measurement of absolute fission rates of eight major fuel isotopes at two different positions within the reactor. The instruments employed in these tests were fission ionization chambers for which the absolute efficiency and fissionable deposit mass assay have been rigorously established.

1981-06-01

397

Double-Edge Molecular Measurement of Lidar Wind Profiles in the VALID Campaign  

Science.gov (United States)

We have developed a transportable container based direct detection Doppler lidar based on the double-edge molecular technique. The pulsed solid state system was built at the University of Geneva. It was used to make range resolved measurements of the atmospheric wind field as part of the VALID campaign at the Observatoire de Haute Provence in Provence, France in July 1999. Comparison of our lidar wind measurements, which were analyzed without knowledge of the results of rawinsonde measurements made under the supervision of ESA, show good agreement with these rawinsondes. These are the first Doppler lidar field measurements made with an eyesafe direct detection molecular-based system at 355 nm and serve as a demonstrator for future spaceborne direct detection wind systems such as the Atmospheric Dynamics mission. Winds are an important contributor to sea surface temperature ...

2000-01-01

398

Benefits of the use of radioisotopes in industrial gauging and control  

International Nuclear Information System (INIS)

Since the radiometric measuring technique was introduced for industrial measuring and control engineering 15 to 20 years ago, the advantages of this technique have become more and more evident and have led to its world-wide application. In the last 15 to 20 years this method has become the standard one in this field. Its major advantages as compared with conventional methods are: contactless measurement; high reliability and accuracy; no mechanically moving parts; and no maintenance required. Despite higher investment costs the application of this method is paid off within a very short time owing to a higher output and the savings in maintenance costs. Some chemo-technical methods can be realized on a grand scale only when radiometric measuring equipment is used - e.g., urea plants, high-pressure polyethylene production. Especially in moisture measurements of ...

399

Alteration of the enterohepatic recirculation of bile acids in rats after exposure to ionizing radiation  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport ...

2004-02-01

400

Summary of Uranium City, Saskatchewan remedial measures for radiation reduction with special attention to vent fan theory  

International Nuclear Information System (INIS)

Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.

1980-03-12

401

Rocket borne solar eclipse experiment to measure the temperature structure of the solar corona via lyman-. cap alpha. line profile observations  

Energy Technology Data Exchange (ETDEWEB)

A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.

1981-01-01

402

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.

1991-01-01

403

Initial electron-beam characterizations for the Los Alamos APEX Facility  

Energy Technology Data Exchange (ETDEWEB)

The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.

1991-12-31

404

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

405

Determination of ash content in coal by means of backscattered X-ray radiation and X-ray fluorescence analysis, and devices manufactured by the PAR company  

Energy Technology Data Exchange (ETDEWEB)

Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.

1993-09-01

406

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

407

Radiation resistance of flexible graphites  

International Nuclear Information System (INIS)

Polymer sealing parts are widely used in various branches of engineering as detachable joints that operate at normal and cryogenic temperatures. They are also used in nuclear-power engineering to seal pumps, pipelines, etc., where they operate at 600-650 K under a neutron fluence of around 10"1"6 cm"-"2 (E #>=# 0.18 MeV) and concomitant #gamma#-irradiation of about 10"6 R. The fluoroplastic-based materials currently used degrade when irradiated in water at 320-360 K with a neutron fluence of 10"1"5 cm"-"2 (thermal neutrons) or 10"1"4 cm"-"2 (fast neutrons), and a concomitant #gamma#-irradiation dose of 2 x 10"6 R. The strength of these fluoroplastics decreases markedly after #gamma#-irradiation (from a cobalt source) at room temperature at doses above 10"6 R. For this reason, flexible and swelling graphites are finding ever increasing application. Graflex foils made of extra-pure natural graphite were found to be radiation-resistant and ...

408

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the charcoal and heat is ...

2006-11-13

409

The PAMELA space mission  

Energy Technology Data Exchange (ETDEWEB)

The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.

2009-03-15

410

Tests for mutagencity of free radicals formed in irradiated sugars and amino acids  

International Nuclear Information System (INIS)

Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.

1977-05-01

411

Strengh functions of strontium 88 obtained from the analysis of the (#gamma#,n) reaction near the threshold  

International Nuclear Information System (INIS)

The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.

1987-09-14

412

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

413

Quantum Cloning for Absolute Radiometry  

International Nuclear Information System (INIS)

In the quantum regime information can be copied with only a finite fidelity. This fidelity gradually increases to 1 as the system becomes classical. In this Letter we show how this fact can be used to directly measure the amount of radiated power. We demonstrate how these principles can be used to build a practical primary standard.

2010-08-20

414

Pyrheliometry  

Energy Technology Data Exchange (ETDEWEB)

Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.

1981-01-01

415

Occupational exposure information system in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)

2005-07-01

416

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

417

Extraction of Kaon Formfactors from K->mu nu gamma Decay at ISTRA+ Setup  

CERN Document Server

The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).

2010-01-01

418

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

Energy Technology Data Exchange (ETDEWEB)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.

1980-10-01

419

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

International Nuclear Information System (INIS)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).

1980-01-01

420

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

421

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray ...

422

Criticality experiments: analysis, evaluation, and programs. 6. CORAL-I Reactor: Evaluation of Critical Experiments and Mass Reactivity Coefficient Measurement  

International Nuclear Information System (INIS)

CORAL-I was an experimental, zero-power, fast-spectrum, high-enriched metal uranium reactor that operated from 1968 until 1988 at the former Junta de Energia Nuclear (JEN), CIEMAT at present. The critical measurements performed at the startup of the reactor are being evaluated as part of the International Critical Safety Benchmark Evaluation Program (ICSBEP) and proposed to be included in its 2001 edition. Additionally, the measurement of the mass reactivity coefficient is compared with MCNP4B calculations. This measurement allows one to perform the approach to critical without the need of a previous control rod calibration, thus enhancing the safety of such an approach. This technique can also be applied to other reactor types. CORAL-I (Ref. 1) is a 90% enriched metal uranium reactor domestically designed and manufactured in the experimental facilities of JEN, now CIEMAT, in Madrid, Spain. The enriched ...

2001-06-17

423

Sensors and instrumentation for atmospheric pollutions control; Capteurs et instrumentation pour le controle des pollutions atmospheriques  

Energy Technology Data Exchange (ETDEWEB)

Reinforcement of the legislation concerning the emission of atmospheric pollutants, aerosols, refrigerants, solvents etc and the reduction of the greenhouse effect, has led to the development of performing instruments for the survey and control of ambient air quality and for the limitation of exhaust gases, combustion products, volatile organic compounds (VOC), particulates and noxious compounds in the atmosphere. This study is divided in 4 main parts. The first part describes the context of the air quality control: the problems linked with the environment and health, the pollutants characteristics, the pollution levels and the detection sensitivity of instruments according to the different type of pollutants (petroleum products, VOCs, ozone compounds, particulates, smells..), the protocols of air pollution measurements and their application (chimney smokes, industrial volatile compounds, indoor and ambient air quality, ...

1996-11-01

425

Replacement of nickel sealing rings by expanded graphite sealing rings -upgrading of SG primary collector flange connection  

Energy Technology Data Exchange (ETDEWEB)

One of the most loaded parts of a steam generator of VVER 440 MW type are the bolts and thread holes of the primary collector cover sealing set. The strength calculations and tensometric measurings performed during operation proved the high degree of a load on the bolts. The conditions of the stress limitation are not met in some cases according to the pertinent standards. The untightnesses at nickel rings occurred during putting the units of Jaslovske Bohunice and Dukovany nuclear power stations into operation. With regard to improve the reliability, the producer has taken measures to improve the quality of the rings and users have introduced more strict regulations for bolts tightening. Due to these measures the high reliability of the set has been obtained from point of view of the tightness, but substantial reduction of bolts and holes threads loading have not been obtained. Several years operation ...

1997-12-31

426

Measurement of the parity violating asymmetry A{sub {gamma}} in n{yields}+p{yields}d+{gamma}  

Energy Technology Data Exchange (ETDEWEB)

The weak interaction between neutrons and protons has never been resolved experimentally. In analogy with the strong NN interaction, the weak NN interaction at low energy can be parametrized in terms of a meson exchange model with parity violating meson-nucleon couplings. Unlike the measured proton-proton weak interaction, the neutron-proton weak interaction is sensitive to the weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. This coupling, which is responsible for the longest-ranged part of the weak NN interaction and is therefore an essential part of any description of weak interactions in nuclei, remains undetermined despite many years of effort. A measurement of the gamma ray directional asymmetry A{sub {gamma}} in the capture of polarized neutrons by parahydrogen has been proposed at Los Alamos National Laboratory. The goal of this experiment is to determine A{sub {gamma}} with a relative ...

2000-02-11

427

Effects of Intensity and Position Modulation On Switched Electrode Electronics Beam Position Monitor Systems at Jefferson Lab  

Energy Technology Data Exchange (ETDEWEB)

Two types of switched electrode electronics beam position monitors are in use at Jefferson Lab. Together they provide accurate beam position to the control system for beam intensities between 50 nA and 2 mA. One version, called the linac style, has a switching frequency of 125 kHz. The other, called the transport type, has a switching frequency of 7 kHz. The basic system provides information to the control system at a 1 Hz update rate. The systems are regularly used to measure the AC component of beam position and energy as well as suppress this motion as part of a fast feedback system. Position data produced by the system are also acquired on an event by event basis as part of the nuclear physics program in two of the experimental halls. This paper will focus on the AC characteristics of the system. These characteristics are affected by analog filter frequencies and a time delay between the measurement ...

2000-05-01

428

Solar energy conversions: solar-electric thermophotovoltaic systems and solar-powered gas lasers  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with conversions of solar energy efficiently into electricity and into gas laser radiation. In the first section, a review study of the possibility of a solar-electric thermophotovoltaic (TPV) device has been done. In a proposed extension of the TPV concept, a Cassagranian optical system concentrates solar radiation to heat a blackbody cavity to 2400/sup 0/K. A double-layer solar cell, GaAs and Si, forming the cylindrical surface concentric to the blackbody cavity, receives the blackbody radiation and converts it into electricity efficiently. A cell conversion efficiency of 50% or more would be possible with the TPV system. The second section explores the concept of blackbody radiation pumping of gas laser media as a step toward utilization of solar energy as a laser pumping source. To demonstrate this concept, an experiment was performed in which various gas mixtures of CO/sub 2/ and ...

1980-12-01

429

Process model for carbothermic production of silicon metal  

Energy Technology Data Exchange (ETDEWEB)

This thesis discusses an advanced dynamical two-dimensional cylinder symmetric model for the high temperature part of the carbothermic silicon metal process, and its computer encoding. The situation close to that which is believed to exist around one of three electrodes in full-scale industrial furnaces is modelled. This area comprises a gas filled cavity surrounding the lower tip of the electrode, the metal pool underneath and the lower parts of the materials above. The most important phenomena included are: Heterogeneous chemical reactions taking place in the high-temperature zone (above 1860 {sup o}C), Evaporation and condensation of silicon, Transport of materials by dripping, Turbulent or laminar fluid flow, DC electric arcs, Heat transport by convection, conduction and radiation. The results from the calculations, such as production rates, gas- and temperature distributions, furnace- and particle geometries, fluid ...

1995-09-12

430

Film ispalators  

International Nuclear Information System (INIS)

New physical objects, ispalators based on free soap films, exhibit persistent flows of the soap solution in open and closed volumes in air with additions of gases of the C_8F_1_8 type (p = 20 Torr) at temperature drops on the films of the order of tenths and hundredths of kelvin. The flows move continuously at a velocity of 5 - 20 cm s"-"1. It is found that the parts of an inclined ispalator film show anomalous behaviour upon heating: their weight increases and they move downward over the film, whereas the unheated parts of the film move upward. Continuous radial vortex flows accompanied by the formation and washing of the regions of a thin black film are observed on circular films in closed volumes upon their uniform external cooling by evaporating water for 5 - 10 hours. The rapid flows make film ispalators the efficient heat carriers, which operate at small temperature drops (tenths and hundredths of kelvin) and surpass copper in the amount ...

2002-05-31

431

Experimental Seminar on Nuclear Energy for Teachers  

Energy Technology Data Exchange (ETDEWEB)

`Experimental Seminar on Nuclear Energy for Teachers` was conducted and sponsored by the Science and Technology Agency. And in order to understand nuclear energy properly through lectures and experiments with good results inclass, the seminar carried out for teachers of high schools and junior high schools by the Nuclear Technology and Education Center (NuTEC), Japan Atomic Energy Research Institute in 1990 FY to 1997 FY. In this report, details of the seminars in the above period are described and No.1 to 17 of Communication Letters of Experimental Seminar on Nuclear Energy` started at 1992 FY are described also. These letters were prepared for attendant follow-up program. And programs of recent seminars, future`s seminars, impressions and comments from attendants, reports from actual classes and others are described in these letters and they are very useful for educational classes on nuclear energy by other teachers. Therefore contents of the letters are listed and easy to refer. A ...

1999-02-01

432

Actual and future strategies in interdisciplinary treatment of medulloblastomas, supratentorial PNET and intracranial germ cell tumors in childhood  

International Nuclear Information System (INIS)

Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting ...

2001-09-01

433

The models of experimental magnetic measurements of various biological samples  

International Nuclear Information System (INIS)

Complete text of publication follows. At the Geomagnetic Institute, in the Laboratory for paleomagnetism and archeomagnetism research and at the Geomagnetic Observatory, Grocka (GCK) during the period from November 2004 to February 2008 the researchers carried out experimental magnetic measurements of the total-intensity gradient of the magnetic field vector (changes in the total magnetisation vector) of various biomaterials. Measurements of the gradient total intensity of the magnetic field vector were carried out by GSM-19 magnetometers of high accuracy and recording resolution (accuracy: #DELTA#F=0.1 nT; sampling rate: 1-5 per second). During these experimental biomagnetic measurements samples of water, tissue, blood, cotton, wool, pitch and magnetite-powder were used. In this study, the part of the biomagnetic measurement results relate to the water, blood and tissue. The ...

2009-08-23

434

Radon Mapping of the Osijek Town  

International Nuclear Information System (INIS)

After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m"-"3, standard deviation of 44.0 Bq m"-"3 and geometric mean of 60.1 Bq m"-"3, for the radon concentration range from 23 to 186 Bq m"-"3. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m"-"3, was in accordance with the theoretical log-normal distribution which was shown with #chi#"2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon ...

1998-11-11

435

Development of lidar techniques for environmental studies  

Energy Technology Data Exchange (ETDEWEB)

The lidar group in Lund has performed many DIAL measurements with a mobile lidar system that was first described in 1987. The lidar system is based on a Nd:YAG-pumped dye laser. During the last few years the lidar group has focused on fluorescence imaging and mercury measurements in the troposphere. In 1994 we performed two campaigns: one fluorescence imaging measurement campaign outside Avignon, France and one unique lidar campaign at a mercury mine in Almaden, Spain. Both campaigns are described in this thesis. This thesis also describes how the mobile lidar system was updated with the graphical programming language LabVIEW to obtain a user friendly lidar system. The software controls the lidar system and analyses measured data. The measurement results are shown as maps of species concentration. All electronics and the major parts of the program are described. ...

1996-09-01

436

Measurement and interpretation of delayed photoneutron effects in multizone criticals with partial D{sub 2}O moderation  

Energy Technology Data Exchange (ETDEWEB)

The effective fraction of delayed photoneutrons ({beta}{sup ph}) has been theoretically defined and experimentally determined in various different configurations of the LWR-PROTEUS critical facility. The peculiarity lies in the fact that the reactor has D{sub 2}O in only one of the four fuelled zones, thus D({gamma},n)H reactions take place mainly in this region. The work is divided into three parts. The first part is devoted to the description of the LWR-PROTEUS facility and to the measurements of {beta}{sup ph}. These experimental values are derived from standard inverse-kinetics analysis of neutron flux decay experiments for each of seven different configurations, with nine additional groups of neutron precursors to account for photoneutron effects. In the second part, the coupled neutron and gamma Boltzmann equations are reduced to exact point kinetics equations using the photon infinite-velocity ...

2003-11-01

437

Technological physics and special materials: wood-plastic composites obtained by radiation polymerization  

International Nuclear Information System (INIS)

General estimates and references are made in connection with the role of technological physics in obtaining materials with specific features. The first part of the paper presents the modification of weak wood essences as well as technological processes at bench-scale and semi industrial scale of wood-plastic composites, under various irradiation conditions. Two technological installations for the fabrication of wood-plastic composites on both scales with technical and practical specifications of their performances are presented. Experimental data for different wood-plastic composite systems using some local wood essences in combination with several polymer and copolymer systems are given. Impregnation and polymerization levels are mentioned for every specific system. The radiation dose rate and integrated dose are given for every experimental polymerization system. The features of the wood-plastic composites are compared with the initial wood ...

1995-12-02

438

Radiation-induced segregation in light-ion bombarded Ni-8% Si  

Energy Technology Data Exchange (ETDEWEB)

Tensile specimens 60 ..mu..m thick of Ni-8 at. % Si have been bombarded at 475/sup 0/C to doses of 0.1 to 0.3 dpa with either 7 MeV proton or 28 MeV alpha particle beams. Deliberate embrittlement by high temperature (700/sup 0/C) preimplantation of helium was required to produce intergranular fracture. Depth profile sputtering and analysis in a Scanning Auger Microprobe was then used to study radiation-induced segregation of silicon both at the external surfaces and at internal interfaces. The external surfaces exhibited a strongly silicon-enriched zone for the first 10 to 20 nm followed by a broad (approx.200 nm), shallow silicon-depleted region. Segregation of silicon to grain boundaries varied from interface to interface and possibly from region to region on a given interface. In general, however, depth profiles of silicon content with distance from internal boundaries showed no noticeable depletion zone and a more gradual fall-off compared to the profiles from ...

1986-01-01

439

Possible preparation of wood-plastic materials based on unsaturated polyester resins and methyl metacrylate, by radiation and chemical methods in combination  

Energy Technology Data Exchange (ETDEWEB)

The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture ...

1982-04-01

440

Possible preparation of wood-plastic materials based on unsaturated polyester resins and methyl metacrylate, by radiation and chemical methods in combination  

International Nuclear Information System (INIS)

The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical polymerization initiators proceeds without the impregnation mixture ...

1982-01-01

441

Optimizing the design of solar energy greenhouses  

Energy Technology Data Exchange (ETDEWEB)

In Canada, the cost of heating is a major expense in the operation of greenhouses in the winter season, inhibiting greenhouse production in winter months in most part of the country. Alternative energy sources, such as solar energy and biomass energy may offer an economically feasible heating alternative. A solar energy greenhouse technology developed in northern China for winter vegetable production has demonstrated good potential for Manitoba winter conditions. The design and performance of solar energy greenhouses depend on the geographical location. Therefore, in order to optimize the design of solar greenhouses with respect to the latitude of the location for maximum solar radiation gain, a theoretical analysis was performed that analyzed parameters such as greenhouse length and the roof slope. This paper described the methodology of the study, including a description of solar energy greenhouses; the energy of solar ...

2006-07-01

442

Effect of humidity in a mixture on combustion (Part 1). Effect on laminar burning velocity  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate the effect of humidity on laminar burning velocity(S), the effect of humidity on the combustion reaction and radiation intensity was studied, taking account of dilution gases such as CO/sub 2/ and Ar which has the approximately identical characteristics to exhaust gas circulation(EGR) gas used to prevent NOx discharge from engines. According to the heat reaction theory, mean specific heat(C) of mixture, mean molecular weight(M) and adiabatic flame temperature(T) etc. were said to affect S but from experimental results, the effect of M and C could be ignored, compared with the effect of T. The relationship between S and H/sub 2/O, Ar of CO/sub 2/% in mixture of diluted gases was clarified. The effect of H/sub 2/O on S was mainly caused by changes of T. The effect of radical C/sub 2/, CH and OH on radiation intensity was similar to that of H/sub 2/O and Ar and the effect of H/sub 2/O on combustion was found only to be the ...

1987-08-25

443

`Procurement quality engineering`: A measurement driven system to assure quality at each step in the procurement process  

Energy Technology Data Exchange (ETDEWEB)

The `Procurement Quality Function` is an element of the Body of Knowledge of Quality Engineering, as defined by the American Society for Quality Control (ASQC). This paper describes the Procurement Quality function which has been installed as an integral part of the Quality Engineering group of the Technical and Management Support Services (T&MSS) contractor to the United States Department of Energy (DOE) Yucca Mountain Site Characterization Project. Each of the elements of the T&MSS Procurement Quality Engineering (PQE) system is discussed along with the measurements obtained. With the installation and development of the PQE system we have attained more meaningful evaluation of supplier capability, reduction of procurement document review reject ratios from 31% to less than 2% per quarter, more effective measurement and control of supplier performance, and the ability to enter into a meaningful teaming effort with ...

1993-12-31

444

Thermal conductivity of polyisocyanurate foam board insulation blown with CFC-11 substitutes: Laboratory and long-term field measurements  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on a series of laboratory and controlled test site measurements of the thermal conductivity of polyisocyanurate foam laminated boardstock roof insulations produced with several different blowing agents; CFC-11, HCFC-123, HCFC-14lb, and two blends of the HCFCs. The behavior of the experimental foams with HCFCs is compared to that of conventional polyisocyanurate foam blown with CFC-11. Thermal drift observed from two years of field exposure is compared to laboratory accelerated aging tests and the laboratory and field measurement techniques are described. This work is part of a Joint Industry/Government Project established in the United States to evaluate the technical viability of HCFC alternative blowing agents for polyisocyanurate foam roof insulations.

1992-01-01

445

The concept of power correction techniques and its use in the reactor regulation and protection systems in Indian PHWRs  

International Nuclear Information System (INIS)

Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)

2010-02-01

446

Studies on adjuvant parenteral nutrition during chemotherapeutic and radiotherapeutic measures in haematological disorders  

International Nuclear Information System (INIS)

In patients subjected to bone marrow transplantation the aggressive measures necessarily preceding this treatment lead to drastic metabolic changes which, in turn, are a cause of marked disturbances of homeostasis. The general preparatory measures in the form of cytoreduction by cytostatic drugs are broadened for leukaemic patients to include wholebody irradiation. During the study described here investigations were carried out into the resulting strain on the metabolism. One of the most essential changes observed in those patients was a nitrogen loss of up to approx. 20 g/day that occurred during the immunosuppressive phase. This was accompanied by markedly pronounced variations in fluid elimination, which partly were of an iatrogenic nature. An immediate and sufficient substitution of amino acids in connection with complete parenteral nutrition rapidly acted to compensate for the nitrogen losses, even though these could ...

447

Implementation of denitrification systems in power plants fueled with brown coal from Rhine region deposits  

Energy Technology Data Exchange (ETDEWEB)

Based on the air pollution values typical of brown coal furnaces the paper discusses pollution abatement measures on the part of fuel engineering and flue gas technology. Fuel engineering contributes to air pollution abatement by measures such as stepped air supply, stepped fuel supply and flue gas draw-in. Flue gas technology largely relies on measures such as the SCR method using different catalytic converters, the noncatalytic reduction of nitrogen oxides, the simultaneous separation of sulfur dioxides and nitrogen oxides, and the Denox-Luvo method. The paper concludes with remarks on the RWE brown coal power plant retrofitting scheme planning to have all power plants equipped with adequate denitrification systems until the end of 1989 at the latest. (orig./PW)

1987-05-01

448

Fast Wire Scanner Calibration  

CERN Document Server

The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner ...

2009-01-01

449

Experimental investigation and modelling of heat capacity, heat of fusion and melting interval of rocks  

Energy Technology Data Exchange (ETDEWEB)

The heat capacity and heat of fusion were measured for a number of minerals using differential scanning calorimetry (DSC). The DSC measurements showed that the heat of fusion for the minerals is very low compared to the heat of fusion for pure crystalline phases reported elsewhere. A model for the melting behaviour of mineral materials in terms of melting interval, heat capacities and heat of fusion has been developed. The only model input is the chemical composition of the mineral material. The model was developed to be implemented in a detailed model of a cupola furnace, thus the focus for the development was not only precision but also to obtain a model that was continuous and differentiable. The model is based on several different submodels that each covers a part of the heating and melting of rocks. Each submodel is based on large amounts of empirical data. Comparison of the model and the DSC ...

2003-11-28

450

Experimental Comparison of Representation Methods and Distance Measures for Time Series Data  

CERN Document Server

The previous decade has brought a remarkable increase of the interest in applications that deal with querying and mining of time series data. Many of the research efforts in this context have focused on introducing new representation methods for dimensionality reduction or novel similarity measures for the underlying data. In the vast majority of cases, each individual work introducing a particular method has made specific claims and, aside from the occasional theoretical justifications, provided quantitative experimental observations. However, for the most part, the comparative aspects of these experiments were too narrowly focused on demonstrating the benefits of the proposed methods over some of the previously introduced ones. In order to provide a comprehensive validation, we conducted an extensive experimental study re-implementing eight different time series representations and nine similarity measures and their ...

2010-01-01

451

Environmental quality assessment in estuarine ecosystems: Use of biometric measurements and fecundity of the ragworm Nereis diversicolor (Polychaeta, Nereididae)  

British Library Electronic Table of Contents (United Kingdom)

The ability to cope with environmental stress may be expensive in terms of energy and this cost of tolerance is suspected to have negative counterparts such as reduced growth and fecundity. To date, condition indices based on biometric measurements are currently used in bivalves or fish but do not exist in endobenthic worms, despite their interest as bioindicators for the sedimentary compartment in which the major part of pollutants is stored in aquatic environments. In the present work, several biometric variables (jaw and total body length, number of segments, the length of the first three segments L3, wet or dry weight) were measured in the ragworm Nereis diversicolor originating from clean (Authie) and polluted (Seine) estuaries (France) to study size-weight relationships. The producti...

2008-01-01

452

A retrospective study of canine hip dysplasia in 116 military workingn> dogs. Part I: Angle measurements and orthopedic foundation for animals (OFA) grading.  

Science.gov (United States)

The progression of hip dysplasia was investigated in 116 military working dogs. Serial pelvic radiographs were graded for degree of dysplasia and degenerative joint disease (DJD). Norberg angles, angles of inclination, and joint space widths were measured. There was a significant correlation between the Norberg angle and the degree of dysplasia (p less than 0.0001). Angles of inclination and joint space width measurements did not demonstrate a correlation to canine hip dysplasia. Dysplastic dogs had a significant estimated risk for development of DJD compared to normal dogs (p less than 0.0001; odds ratio of 70.2). Dogs with normal hip conformation at 24 months of age or older did not develop moderate nor severe DJD. PMID:8875357

453

Year-1 (heavy-ion) physics with CMS at the LHC  

International Nuclear Information System (INIS)

The plans for the CERN LHC heavy ion program in 2010 are for collisions of lead ions during the month of November at an energy about half of the final 5.5 TeV/nucleon. The advanced preparations are mostly for extrapolations of the measurements at the maximum energy previously available, Au + Au at 0.2 TeV/nucleon. Because of the large increase in energy, surprises can be expected. One new feature made possible by the increased energy and the excellent muon energy resolution of CMS will be the study of the yields of the excited states of the upsilon meson as a function of angle and centrality. Although the main emphasis will be on the QGP formed by the overlapping parts of the Pb ions, the spectator parts and the electromagnetic field outside of the ions, #gamma#-Pb and #gamma##gamma#, are also important.

2010-06-01

454

X-ray fluorescence in research on Czech cultural monuments  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

455

X-ray fluorescence in research on Czech cultural monuments  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis (RXRFA), as a non-destructive method, relatively simple and allowing measurements to be carried out in situ, is an excellent tool in research on various objects of art. A range of artefacts have been investigated by our laboratory, in part for the purposes of history of art and in part as a basis for restoration works - medieval frescoes in some Czech castles and churches, metal sculptures and objects of applied art, paints and inks of old manuscripts, paintings. Some of these are among the most valuable monuments in the Czech cultural heritage. The contribution of the results of the tests to the investigation of their 'life story' and, in some cases, to their conservation, is not negligible. Later additions and repairs can be recognised, and materials and technologies that are close to their historic counterparts can be used in restoration work.

2004-01-01

456

Reference materials to evaluate measurement systems for the nutrient composition of foods: results from USDA?s National Food and Nutrient Analysis Program (NFNAP)  

British Library Electronic Table of Contents (United Kingdom)

Over a 6.5-year period a total of 2554 values were reported by nine laboratories for 259 certified or reference nutrient concentrations in 26 certified reference materials (CRM) submitted to contract laboratories, blinded, as part of the qualifying process for analytical contracts and in the routine sample stream as part of the National Food and Nutrient Analysis Program. Each value was converted to a Z?-score, reflecting the difference from the assigned value related to the combined expected analytical uncertainty plus the uncertainty in the CRM value. Z?-scores >|3.0| were considered unacceptable. For some nutrients (Na, folate, dietary fiber, pantothenic acid, thiamin, tocopherols, carotenoids, monounsaturated, and polyunsaturated fatty acids), >20% of Z?-scores were >|3.0|. For total f...

2007-01-01

457

Preparation and characterization of nano hydroxyapatite/polymeric composites materials. Part I  

British Library Electronic Table of Contents (United Kingdom)

The present study is focused on preparation of nano composite materials and the effect of citric acid on their different properties. The formation of nano HA and its interaction with chitosan (C), gelatin (G) polymers and citric acid (CA) materials were studied. The Fourier Transformed Infrared Spectroscopy (FT-IR), X-ray diffraction (XRD), thermo-gravimetric analysis (TGA), transmission electron microscope (TEM), and scanning electron microscope (SEM) were used to characterize these composite materials. The compressive strength (CS) was also measured to know the reinforcement of the prepared composites. The results show that carboxylic and amino groups play crucial role for HA formation on chitosan-gelatin polymeric matrix in the presence of citric acid (CA). The formation of nano HA part...

2011-01-01

458

PREVENTION OF INFECTION IN PATIENTS WITH CHRONIC KIDNEY DISEASE PART III: SURVEILLANCE AND AUDITING IN A RENAL CARE ENVIRONMENT  

British Library Electronic Table of Contents (United Kingdom)

Summary This third paper, in a three-part CE series on the preventions of infection in patients with chronic kidney disease, focuses on surveillance and auditing of healthcare-associated infections within the renal care environment. The last decade has seen an increased awareness of the threat to patient safety from healthcare-associated infection (HCAI) and the emergence of multi-drug resistance organisms. Effective HCAI prevention strategies include adequate governance structures, access to expert advice, adherence to standard and transmission-based precautions, minimising the use of invasive medical devices, and surveillance. Surveillance data can be collected using outcome (e.g. infection) and/or process (e.g. hand hygiene compliance audit) measures. Establishing a surveillance program...

2011-01-01

459

Kramers-Kronig Analysis of Infrared Reflectance Spectra for Quaternary In_xAl_yGa_1_-_x_-_yN Alloy  

International Nuclear Information System (INIS)

In this paper, a Kramers-Kronig (KK) analysis of infrared (IR) reflectance spectrum of quaternary In_0_._0_1Al_0_._0_6Ga_0_._9_3N film grown by molecular beam epitaxy (MBE) is reported. The infrared measurement is performed in the reflection mode at an incident angle of 15 degree sign by Fourier transform infrared (FTIR) spectroscopy at T = 300 K. The Kramers-Kronig analysis of the reflectivity data has been used to obtain the real and imaginary parts of the index of refraction (n and k), and the real and imaginary parts of the dielectric response function (#epsilon#' and #epsilon#') of the materials. Finally, the transverse optical and longitudinal optical phonons for quaternary In_xAl_yGa_1_-_x_-_yN were obtained.

2010-07-07

460

Effective thermal conductivity and thermal contact resistance of gas diffusion layers in proton exchange membrane fuel cells. Part 2: Hysteresis effect under cyclic compressive load  

British Library Electronic Table of Contents (United Kingdom)

Heat transfer through the gas diffusion layer (GDL) is a key process in the design and operation of a PEM fuel cell. The analysis of this process requires the determination of the effective thermal conductivity as well as the thermal contact resistance between the GDL and adjacent surfaces/layers. The Part 1 companion paper describes an experimental procedure and a test bed devised to allow separation of the effective thermal conductivity and thermal contact resistance, and presents measurements under a range of static compressive loads. In practice, during operation of a fuel cell stack, the compressive load on the GDL changes. In the present study, experiments are performed on Toray carbon papers with 78% porosity and 5% PTFE under a cyclic compressive load. Results show a significant hy...

2010-01-01

461

1992 Conversion Resources Supply Document  

Energy Technology Data Exchange (ETDEWEB)

In recent years conservation of electric power has become an integral part of utility planning. The 1980 Pacific Northwest Electric Power Planning and Conservation Act (Northwest Power Act) requires that the region consider conservation potential in planning acquisitions of resources to meet load growth. The Bonneville Power Administration (BPA) developed its first estimates of conservation potential in 1982. Since that time BPA has updated its conservation supply analyses as a part of its Resource Program and other planning efforts. Major updates were published in 1985 and in January 1990. This 1992 document presents updated supply curves, which are estimates of the savings potential over time (cumulative savings) at different cost levels of energy conservation measures (ECMs). ECMs are devices, pieces of equipment, or actions that increase the efficiency of electricity use and reduce the amount of electricity used by ...

1992-03-01

462

Training And Education Needs In Radiological Protection - First Results Of The ENETRAP Survey  

Energy Technology Data Exchange (ETDEWEB)

Recent studies have shown that there is a wide variety of approaches to education and training of the Qualified Expert across the European Union. National education and training programmes show often large differences in content, duration, level, the introduction of practical work, etc. As they stand, such differences are a barrier to the mutual recognition of the Qualified Expert status and, in part, are contributing to a perceived shortage in expertise in radiation protection and safety. The overall aim of ENETRAP is to determine mechanisms that in the longer term will facilitate better integration of education and training activities (with a view to mutual recognition across the European Union) and to ensure the ongoing provision of the necessary competence and expertise at the level of the Qualified Expert. The ENETRAP project is a 6FP coordination action. It started in April 2005 and runs over a period of 24 months. (authors)

2006-07-01

463

The physics of tachyons. Part 4. Tachyon electrodynamics  

Energy Technology Data Exchange (ETDEWEB)

A new formulation of the theory of tachyons using the same two postulates as in special relativity is applied to the electrodynamics of material media. A discussion of Lagrange`s equations and Hamilton`s equations for `classical` charged tachyons shows that such a formalism is a viable approach. An essay is included on why tachyons can be considered to be localised particles for the purpose of calculations. Tachyonic transformations of the electromagnetic fields D, P, H and M are shown to be the same as for bradyonic transformations. Examples discussed include the electric dipole moment of a tachyonic current loop, constitutive equations, polarisation in tachyonic dielectric materials and the velocity of light in tachyonic dielectric media. This is followed by discussions of the collision energy loss for charged tachyons interacting with a material medium and a mathematical proof that tachyons cannot emit Cherenkov radiation when passing through a bradyonic ...

1998-12-31

464

The physics of tachyons. Part 4. Tachyon electrodynamics  

International Nuclear Information System (INIS)

A new formulation of the theory of tachyons using the same two postulates as in special relativity is applied to the electrodynamics of material media. A discussion of Lagrange's equations and Hamilton's equations for 'classical' charged tachyons shows that such a formalism is a viable approach. An essay is included on why tachyons can be considered to be localised particles for the purpose of calculations. Tachyonic transformations of the electromagnetic fields D, P, H and M are shown to be the same as for bradyonic transformations. Examples discussed include the electric dipole moment of a tachyonic current loop, constitutive equations, polarisation in tachyonic dielectric materials and the velocity of light in tachyonic dielectric media. This is followed by discussions of the collision energy loss for charged tachyons interacting with a material medium and a mathematical proof that tachyons cannot emit Cherenkov radiation when passing through a bradyonic ...

465

Preliminary Calculations of the Radiation Damage of the Permanent Magnets for TRADE (TRiga Accelerator Driven Experiment)  

CERN Document Server

Monte Carlo calculations of proton irradiation of permanent magnets for the TRADE experiment have been performed. An irradiation dose of about 4´106 Gy/yr/mA has been estimated due to beam losses in normal operating conditions. Existing experimental results indicate that this irradiation level may induce a considerable demagnetization: in fact, a dose of 6´107 Gy induces a remanence loss of 0.3 % on samples of Sm2Co17 magnets, which are the most resistant type. More detailed calculations with the final design of the magnets and of the beam line are suggested, to determine if the irradiation levels allowed a reliable operation of the permanent magnets for the entire duration of the TRADE experiment. Damage and gas production rates have also been calculated; the values obtained are very low, thus confirming that the demagnetization process is in great part reversible.

2002-01-01

466

Effects of pre- and postnatal exposure to tritiated water for five generations on postnatal brain development  

International Nuclear Information System (INIS)

The possible long-term effects of chronic radiation exposure have been studied. Rats were given tritiated drinking water (3 #mu#Ci/ml) before and during pregnancy and thereafter continuously through five generations. The brains were studied at 30 and 120 days postnatally. Significant decreases in weight and DNA and protein contents of specific parts of the brain were found, the most pronounced decreases being in the diencephalon. The decrease in protein content were more pronounced than the decreases in DNA content; the decreases were also more pronounced at 30 days than at 120 days, and more pronounced in the fith generation than in previous generations.

467

Diagnostics hardening for harsh environment in Laser Megajoule (invited)  

International Nuclear Information System (INIS)

The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

2008-10-01

468

Corrosion behavior of iron and nickel base alloys in high temperature and pressure water  

International Nuclear Information System (INIS)

In equipment industries, the equipments handling industrial water and pure water are numerous. In power generation including nuclear power generation, water serves as a working medium. Review is made on the experiences in the corrosion of iron and nickel base alloys in high temperature, high pressure water and the results of researches derived from them. Under high temperature and high pressure, carbon steel, low alloy steel, stainless steel and high nickel alloy cause corrosion even in pure water. But in the case of serious corrosion, chlorine, oxygen, alkali and others in water take part. The following matters are described: corrosion by steam; stress corrosion cracking in pure water; corrosion by impurities in high temperature, high pressure pure water, i.e. chlorine ions, dissolved oxygen, and alkali; corrosion under radiation. (J.P.N.).

469

Chronic irradiation and brain development. Final (4th) progress report  

International Nuclear Information System (INIS)

The possible long term effects of chronic radiation exposure have been studied. Rats were given tritiated drinking water (3#mu#Ci/ml) before pregnancy, during pregnancy and threafter, continuously through 5 generations. The brains were studied at 30 and 120 days postnatally. Significant decreases in weight, DNA and protein contents of specific parts of the brain were found, the most pronounced decreases being in the diencephalon. The decreases in protein content were more pronounced than the decreases in DNA content; the decreases were also more pronounced at 30 days than at 120 days, and more pronounced in the fifth generation than in previous generations. An attempt was made to explain these complex phenomena on the basis of known periods of proliferation of various brain cells, damage to mothers themselves in each generation, and damage and repair of nucleic acids caused by radioactivity.

470

A.C.R.O. activity report 2006; A.C.R.O. rapport d'activite 2006  

Energy Technology Data Exchange (ETDEWEB)

This association participated in different working groups: North Cotentin radioecology group, groups of expertise on the uranium mines of Limousin, executive committee for the management of the post accidental phase of a nuclear accident or a radiological emergency situation, radioactive waste management, radiological surveillance of the territory, radiation protection mission by the Asn, radiological surveillance of the environment of the Chinon nuclear power plant, study of the presence of {sup 235}U around the site of Brennilis, study of the radioactive waste management at the Manche plant, radiological surveillance of the Cyceron cyclotron at Caen, Aurengo commission on the consequences in France of the Chernobylsk accident. Actions of information, regular publications, meeting with public are also a part of the work of this association. (N.C.)

2006-07-01

471

Radiation inactivation target size of rat adipocyte glucose transporter  

Energy Technology Data Exchange (ETDEWEB)

In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due to an interaction with a ...

1987-05-01

472

Radiation hardening and radiation-induced chromium depletion effects on intergranular stress corrosion cracking in austenitic stainless steels  

International Nuclear Information System (INIS)

Radiation hardening and radiation-induced chromium (Cr) depletion were related to intergranular stress corrosion cracking (IGSCC) response among various stainless steels (SS). Available data on neutron-irradiated materials were analyzed and correlations developed between fluence, yield strength, grain-boundary Cr concentration, and cracking susceptibility in high-temperature water environments. Large heat-to-heat differences in the critical fluence (0.2 neutrons/cm"2 to 2.5 x 10"2"1 neutrons/cm"2) for IGSCC were documented. Variability often was consistent with yield strength differences among irradiated materials. IGSCC correlated better to yield strength than to fluence for most heats, suggesting a possible role for radiation-induced hardening (and microstructure) on cracking. However, isolated heats revealed a wide range of yield strengths (450 MPa to 800 MPa) necessary to promote IGSCC which could not be explained by ...

473

Understanding and predicting soot generation in turbulent non-premixed jet flames.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the results of a project funded by DoD's Strategic Environmental Research and Development Program (SERDP) on the science behind development of predictive models for soot emission from gas turbine engines. Measurements of soot formation were performed in laminar flat premixed flames and turbulent non-premixed jet flames at 1 atm pressure and in turbulent liquid spray flames under representative conditions for takeoff in a gas turbine engine. The laminar flames and open jet flames used both ethylene and a prevaporized JP-8 surrogate fuel composed of n-dodecane and m-xylene. The pressurized turbulent jet flame measurements used the JP-8 surrogate fuel and compared its combustion and sooting characteristics to a world-average JP-8 fuel sample. The pressurized jet flame measurements demonstrated that the surrogate was representative of JP-8, with a somewhat higher tendency to soot formation. The ...

2010-10-01

474

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with ...

2002-07-01

475

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with ...

2001-12-21

476

Thermal diffusivity measurements of irradiated UO_2 pellets  

International Nuclear Information System (INIS)

Thermal diffusivity was measured with a laser flash method up to 2000 K for UO_2 pellets irradiated in a commercial reactor. Measurements were done on micro samples of disks (2 mm diameter) or regular prisms (1.5 or 2 mm square cross sections). Thermal diffusivity degraded on extending burnup in agreement with reported values for UO_2 irradiated in test reactors, and it showed hysteresis during the laser flash experiments. Thermal diffusivity began to recover above 750 K and almost completely recovered above 1400 K, which corresponded with the reported radiation damage recovery. The obtained data were in agreement with predictions applying the thermal conductivity expression for irradiated UO_2 proposed by Amaya and Hirai. The sample experiencing power ramp showed higher thermal diffusivity than that of the base irradiated sample and had no obvious hysteresis. This suggested that the radiation damage ...

1998-08-01

477

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the ...

2000-05-01

478

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

479

High order statistical signatures from source-driven measurements of subcritical fissile systems  

Energy Technology Data Exchange (ETDEWEB)

This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility ...

1998-04-01

480

Title of paper: the induction of P-53 independent programmed cell death (apoptosis) with ionizing radiation and 5-fluorouracil (5-FU) in the HT-29 human colon carcinoma cell line  

International Nuclear Information System (INIS)

Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 ...

1996-09-01

481

The radon therapy - radon inhalatorium in Kowary  

International Nuclear Information System (INIS)

In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)

482

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...

483

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

484

QCD corrections to top quark pair production in association with a photon at hadron colliders  

CERN Document Server

We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.

2011-01-01

485

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

486

Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures  

International Nuclear Information System (INIS)

The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.

487

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

489
490

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

491

Summary of the engineering assessment of inactive uranium mill tailings, Spook Site, Converse County, Wyoming  

Energy Technology Data Exchange (ETDEWEB)

Ford, Bacon, Davis Utah Inc. has reevaluated the Spook site in order to revise the December 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings 48 mi northeast of Casper, in Converse County, Wyoming. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 187,000 tons of tailings at the Spook site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.

1981-10-01

492

Radiation streaming analysis of horizontal penetrations in calandria vault of TAPP-3, 4  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal penetrations in Calandria Vault of 540 MWe PHWR. There are total 19 penetrations, penetrating east and west walls of calandria vault of 540 MWe PHWR. These penetrations are provided to accommodate ion chambers. HFUs and SDS - 2. Penetrations described here are not present in 220 MWe units except for ion chamber penetrations. As these penetrations are in accessible area, a detailed analysis has been carried out to find out the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out using computer code DOT-III and MCNP. Predictions by this method compare well with the measurements at ion chamber locations at KGS-1,2. (author)

2006-11-13

493

Photoluminescence enhancement of Sm{sup 3+} ions in the vicinity of noble-metal nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

The photoluminescence intensity of an optical emitter changes when placed in close proximity to a noble-metal nanoparticle, due to two contributions. First, the optical near-field of the nanoparticle leads to a change in excitation rate of the emitter. Secondly, the emission efficiency is changed due to an optical energy transfer from the emitter to the metal nanoparticle, which provides additional radiative and non-radiative decay channels. In this work we investigate the photoluminescence of Sm{sup 3+} ions, which are embedded in SiO{sub 2}. The photoluminescence spectrum of ions in proximity to single silver and gold nanoparticles is measured. The influence of the spectral position of the nanoparticle plasmon peak on the photoluminescence yield will be discussed and compared with model calculations.

2009-07-01

494

Engineering assessment of inactive uranium mill tailings, Tuba City site, Tuba City, Arizona  

Energy Technology Data Exchange (ETDEWEB)

Ford, Bacon and Davis Utah Inc. has reevaluated the Tuba City site in order to revise the March 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings at Tuba City, Arizona. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 0.8 million tons of tailings at the Tuba City site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.

1981-09-01

495

Effects of stress on radiation hardening and microstructural evolution in A533B steel  

British Library Electronic Table of Contents (United Kingdom)

Bent specimens of A533B steel (0.16wt% Cu) were irradiated at 290degreeC to 1dpa with 6.4MeV Fe3+ ions. Calculated tensile stresses at the irradiated surface were set to 0, 250, 500 and 750MPa. The specimens were subjected to hardness measurements, transmission electron microscopy (TEM) observations and three-dimensional atom probe (3DAP) analysis. The radiation-induced hardening decreased with increasing stress to 500MPa which was near the yield strength. TEM and 3DAP results showed that well-defined dislocation loops and solute clusters were formed. The diameter of dislocation loops increased and the number density decreased when the stress was applied, whereas the diameter and number density of solute clusters decreased. The hardening was mainly attributed to solute cluster formation. A...

2010-01-01

496

Design concept for radiation hardening of low power and low voltage dynamic memories  

International Nuclear Information System (INIS)

A radiation hard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study.

497

Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women  

International Nuclear Information System (INIS)

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.

1987-01-01

498

Channeling studies of radiation damage in metal-silicides  

Science.gov (United States)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.

1978-01-01

499

Channeling studies of radiation damage in metal-silicides  

International Nuclear Information System (INIS)

Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.

500

A miniaturized spatial temperature gradient capillary electrophoresis system with radiative heating and automated sample introduction for DNA mutation detection  

British Library Electronic Table of Contents (United Kingdom)

Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...

2010-01-01