International Nuclear Information System (INIS)
A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed
International Nuclear Information System (INIS)
The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.
Development of calibration facility for radiation protection monitoring instruments
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration ...
2008-11-19
Basic mechanisms of radiation effects in the natural space radiation environment
Energy Technology Data Exchange (ETDEWEB)
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
1994-06-01
Four cases of bowel perforation following radiation therapy for cervical cancer
Energy Technology Data Exchange (ETDEWEB)
External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.
1984-10-01
International Nuclear Information System (INIS)
The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population ...
1984-01-01
Radiation resistance of nylon. [Gamma radiation
Energy Technology Data Exchange (ETDEWEB)
Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in ...
1983-12-01
Measurement of the ratio of liquid to solid phases in a continuous ingot
International Nuclear Information System (INIS)
A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the ...
Energy Technology Data Exchange (ETDEWEB)
Measurements of the photon angular distribution of Radiative Electron Capture into the M shell have been performed with He-like uranium ions in the range 110-140 MeV/u. In addition, L REC was studied at a projectile energy of 140 MeV/u. In both cases, the experimental data show an asymmetry around 90 and agree well with a fully relativistic theory. (orig.) 15 refs.
1995-10-01
Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles
International Nuclear Information System (INIS)
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
1980-06-01
Electron scattering from atoms in the presence of a laser field. II
In the first paper of this series a formal theory of atomic scattering of electrons in the presence of an intense electromagnetic field was given. Cross sections, near the forward direction, between atomic states (modified by the laser) were obtained. However, it was assumed that the atom could not emit spontaneous radiation. In this paper the effect of spontaneous radiation is included, and it is shown that in most cases the measured cross section will be a weighted average of the two different cross sections starting from the two different initial states which are those atomic states resonantly linked by the laser. The Born approximation for the scattering is obtained, and it is shown that for the simplest description of the spontaneous radiation field the effect of the laser on the cross sections is simply to multiply them by a factor which depends upon the laser detuning. (AIP)
1976-10-01
On the determination of the dose-area product during X-ray examinations
International Nuclear Information System (INIS)
Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total ...
Impact of radiation measurements on hardening of TFTR diagnostics
International Nuclear Information System (INIS)
Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have ...
Measurement of fast fluctuations of radiation intensity in pulsed charged particle accelerators
International Nuclear Information System (INIS)
... beam monitoring betatrons delay circuits errors fluctuations gamma radiation
International Nuclear Information System (INIS)
Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it ...
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, ...
2009-05-26
Energy Technology Data Exchange (ETDEWEB)
The Argonne Boundary Layer Experiments (ABLE) facility, located in south central Kansas, east of Wichita, is devoted primarily to investigations of and within the planetary boundary layer (PBL), including the dynamics of the mixed layer during both day and night; effects of varying land use and land form; the interactive role of precipitation, runoff, and soil moisture; storm development; and energy budgets on scales of 10 to 100 km. Located entirely within the Walnut River watershed, ABLE provides intense measurements within the northeast quadrant (Fig. 1) of the Southern Great Plains (SGP) Cloud and Radiation Testbed (CART) of the Atmospheric Radiation Measurement (ARM) Program (Stokes and Schwarz, 1994). By combining the continuous measurements of ABLE with ancillary continuous measurements of, for example, the ARM and the Global Energy Water cycle Experiment ...
1998-06-05
International Nuclear Information System (INIS)
The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially ...
Radiation protection in the operating room
International Nuclear Information System (INIS)
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
International Nuclear Information System (INIS)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product ...
Neutrinos produced by nuclei injected by young pulsars inside compact massive binaries
Energy Technology Data Exchange (ETDEWEB)
We consider propagation of relativistic heavy nuclei injected by a young pulsar into the radiation field of a massive companion. If the binary system (BS) is compact enough, then the nuclei suffer multiple photodisintegrations in collisions with thermal photons coming from the massive star (MS). Due to the propagation effects of charged particles in the magnetic field of the MS some hadrons can impinge onto the MS surface at large angles. We calculate the fluxes of produced neutrinos as a function of the viewing angle measured from the plane of the BS. It is found that significant fluxes of neutrinos should be also expected in the case of non-eclipsing BSs.
2005-06-15
Accidents - Chernobyl accident; Accidents - accident de Tchernobyl
Energy Technology Data Exchange (ETDEWEB)
This file is devoted to the Chernobyl accident. It is divided in four parts. The first part concerns the accident itself and its technical management. The second part is relative to the radiation doses and the different contaminations. The third part reports the sanitary effects, the determinists ones and the stochastic ones. The fourth and last part relates the consequences for the other European countries with the case of France. Through the different parts a point is tackled with the measures taken after the accident by the other countries to manage an accident, the cooperation between the different countries and the groups of research and studies about the reactors safety, and also with the international medical cooperation, specially for the children, everything in relation with the Chernobyl accident. (N.C.)
2004-07-01
British Library Electronic Table of Contents (United Kingdom)
The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.
2011-01-01
Numerical analysis of methane-air combustion considering radiation effect
Energy Technology Data Exchange (ETDEWEB)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation ...
2008-12-15
Numerical analysis of methane-air combustion considering radiation effect
International Nuclear Information System (INIS)
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect ...
2008-12-01
Real-time neutron monitoring method using an imaging plate
Energy Technology Data Exchange (ETDEWEB)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
1999-07-01
Real-time neutron monitoring method using an imaging plate
International Nuclear Information System (INIS)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
1999-04-19
International Nuclear Information System (INIS)
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and ...
1993-01-01
Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children
Energy Technology Data Exchange (ETDEWEB)
During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 ...
1996-03-01
VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...
Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
Radiation accidents with multi-organ failure in the United States.
Only a small number of radiation accidents in the United States have been severe enough to result in multi-organ failure (MOF). Medical details of selected medical misadministration and criticality cases are reviewed, with an emphasis on pathophysiology. The four criticality cases are particularly relevant for analysis of MOF, since medical treatment was supportive and did not appreciably alter the clinical evolution of radiation injury. PMID:15975871
2005-01-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...
2010-10-01
Ignition Phenomena in Developmental, Stick Propellant ...
... TEMPERATURE, PRESSURE MEASUREMENT, GUN CHAMBERS, COMPACTING, COMBUSTIBLE CARTRIDGE CASES, FLASH RADIOGRAPHY ...
1984-07-01
Radiative corrections to the atomic levels in a periodic electromagnetic field
Energy Technology Data Exchange (ETDEWEB)
The influence of a periodic electromagnetic field on the radiative corrections to the atomic energy levels is studied for the case of ''strong fields'' for which the interaction between the atom and field is of the order or greater than the radiative effects. The analysis is carried out on the basis of the Schwinger-Dirac equation for the propagation function of a bound electron in the field and on the basis of the density matrix in the Furry representation. It is shown that in the strong field approximation the radiative shifts and widths are manifest as radiative corrections to the quasi-energies. In super-high resolution experiments intensity effects in the radiative corrections to the atomic levels are obtained in the case of single-photon resonance. Some multiphoton processes are condidered by taking ...
1982-12-01
Radiation exposure due to X-rays of the hip joint in babies
International Nuclear Information System (INIS)
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Energy Technology Data Exchange (ETDEWEB)
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
1993-01-01
Cooperative spontaneous emission from two different atoms
International Nuclear Information System (INIS)
The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).
1986-01-01
International Nuclear Information System (INIS)
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
2001-07-01
International Nuclear Information System (INIS)
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and ...
2008-05-01
X-ray dosimetry of TlGaSe_2 single crystals
International Nuclear Information System (INIS)
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray ...
Development of a real-time, neutron and gamma dosimeter
Energy Technology Data Exchange (ETDEWEB)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-07-01
Development of a real-time, neutron and gamma dosimeter
International Nuclear Information System (INIS)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-06-10
Radiation-induced large intracranial vessel occlusive vasculopathy.
Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and ...
1980-01-01
Radiation-induced large intracranial vessel occlusive vasculopathy
Energy Technology Data Exchange (ETDEWEB)
Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and ...
1980-01-01
Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev
International Nuclear Information System (INIS)
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
2003-02-01
Lifetime measurements of singlet ungerade states in isotopic molecular nitrogen
International Nuclear Information System (INIS)
Full text: In the upper layers of the Earth's atmosphere, molecular nitrogen absorbs the extreme ultraviolet (XUV) solar radiation. The absorption is associated with dipole-allowed excitation of states of singlet ungerade symmetry ("1#SIGMA#"+_u and "1#PI#_u), which are known to undergo predissociation due to coupling with a mainfold of "1#PI#_u states. We determined new N_2 isotopic lifetimes of many "1#SIGMA#"+_u and "1#PI#_u states via line broadening measurements in the frequency domain. Ultrahigh resolution XUV + UV ionization spectra were recorded (bandwidth #approx# 250 MHz, resolving power 10"7), from which the natural linewidth, i.e. lifetime, was determined. These lifetimes provide new information about the predissociation of the singlet ungerade states in N_2. Tunable narrowband XUV radiation was produced by successively pulsed amplification of cw dye laser radiation, frequency doubling the ...
2004-07-19
Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects
Energy Technology Data Exchange (ETDEWEB)
Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate annual facial UV ...
1996-12-31
Measurement of nuclear magnetic moments by perturbed polarization-directional angular correlation
International Nuclear Information System (INIS)
... radiations isotopes magnetic moments nuclear cascades nuclear properties
Energy Technology Data Exchange (ETDEWEB)
The current status of rare B decays is reviewed based on recent observation of the penguin-diagram decay B {yields} K{sup *}{gamma} at CLEO. Rare B decays provide valuable information on the Standard Model parameters, and also could be a source of direct CP violation. It is emphasized that new physics beyond the Standard Model can appear in rare B decays, in some cases more drastically than in the CP Asymmetry of the B system. Inclusive measurement of the radiative transition b {yields} s{gamma} is promising. Hadronic penguin modes are very close to being observed at CLEO, and a discovery might be just around the corner. (author). 48 refs., 6 figs., 4 tabs.
1994-12-31
Properties of transition metal-doped zinc chalcogenide crystals for tunable IR laser radiation
Energy Technology Data Exchange (ETDEWEB)
The spectroscopic properties of Cr{sup 2+}, Co{sup 2+}, and Ni{sup 2+}-doped single crystals of ZnS, ZnSe, and ZnTe have been investigated to understand their potential application as mid-IR tunable solid-state laser media. The spectroscopy indicated divalent Cr was the most favorable candidate for efficient room temperature lasing, and accordingly, a laser-pumped laser demonstration of Cr:ZnS and Cr:ZnSe has been performed. The lasers` output were peaked at {approximately} 2.35 {mu}m and the highest measured slope efficiencies were {approximately} 20% in both cases.
1995-03-17
Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1
International Nuclear Information System (INIS)
The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.
1988-01-01
Plasma diagnostics by spectra from LHD and atomic data
International Nuclear Information System (INIS)
We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)
2009-04-01
Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)
Energy Technology Data Exchange (ETDEWEB)
Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).
1991-01-01
Effective radiation therapy on two cases of primary Ewing's sarcoma of the rib
International Nuclear Information System (INIS)
Two cases of primary Ewing's sarcoma of the rib are reported, in which radiation therapy was quite effective. Case 1 was an 18-year-old female who had had an operation and radiation therapy for Ewing's sarcoma of the left 7th rib. She was referred to our hospital after a recurrent tumor was found. Radiation therapy (tumor dose 46.2 Gy) and chemotherapy were given. The tumor disappeared and there has been no relapse for 1 year and 3 months after the treatment. Case 2 was a 2-year-old-infant. Radiation therapy (tumor dose 74 Gy) was given for primary Ewing's sarcoma of the left 6th rib. The tumor became small and was successfully removed at operation. There has been no relapse or distant metastasis for 8 months following the operation. We emphasize the importance of multidisciplinary treatment in case 1 and the usefulness ...
Radiation-stimulated diffusion of aerosols
Energy Technology Data Exchange (ETDEWEB)
The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.
1984-04-01
Energy Technology Data Exchange (ETDEWEB)
Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.
1980-08-01
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used ...
International Nuclear Information System (INIS)
From the indoor radon problem arises a great challenge for the radiation protection of the population. The soil can be considered as the only source for high radon concentrations in buildings. The contribution of common building materials to high indoor concentrations with a range of 30 Bq/m"3 is negligible low. Therefore building materials for radon mitigation should be judged by their tightness against diffusive radon and not by their radon exhalation rate. Also isolation materials for mitigation should be radon tight. The radon diffusion coefficient describes the physical processes in relatively homogeneous samples. The diffusion coefficient D and the diffusion length R are very exactly determined by a self engineered measuring method. The range of D reaches from D = (0.0005 to 2.35) . 10"-"6 m"2/s for building materials and from D = (0.07 to < 10"-"6) . 10"-"6 m"2/s for isolation materials. Applicable mitigation ...
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the ...
1996-12-31
A comprehensive understanding of the efficacy of N-Ring hardening methodologies in SiGe HBTs
International Nuclear Information System (INIS)
We investigate the efficacy of mitigating radiation-based single event effects (SEE) within circuits incorporating SiGe heterojunction bipolar transistors (HBTs) built with an N-Ring, a transistor-level layout-based radiation hardened by design (RHBD) technique. Previous work of single-device ion-beam induced charge collection (IBICC) studies has demonstrated significant reductions in peak collector charge collection and sensitive area for charge collection; however, few circuit studies using this technique have been performed. Transient studies performed with Sandia National Laboratory's (SNL) 36 MeV 16O microbeam on voltage references built with N-Ring SiGe HBTs have shown mixed results, with reductions in the number of large voltage disruptions in addition to new sensitive areas of low-level output voltage disturbances. Similar discrepancies between device-level IBICC results and circuit measurements are found for the ...
2010-07-19
British Library Electronic Table of Contents (United Kingdom)
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
2011-01-01
Comparison and analysis of results of ? radiation level investigation around Daya Bay
International Nuclear Information System (INIS)
Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)
2003-08-01
International Nuclear Information System (INIS)
Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 ...
1996-09-01
Porosity Measurement of Combustible Cartridge Case Materials.
Research to develop an accurate and reproducible density test for 60-mm and 81-mm mortar propellant increment containers (combustible cartridge cases) was not successful. However, application of modern industrial porosity measurement techniques may afford...
1981-01-01
Equipment hardening and hardness assurance
International Nuclear Information System (INIS)
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to ...
Enhanced coherent undulator radiation from bunched electron beams
International Nuclear Information System (INIS)
When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch ...
1995-09-28
Measurement methods for human exposure analysis.
UK PubMed Central (United Kingdom)
The general methods used to complete measurements of human exposures are identified and illustrations are provided for the cases of indirect and direct methods used for exposure analysis. The application...Full Text Available
1995-04-01
Energy Technology Data Exchange (ETDEWEB)
The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving ...
1981-06-01
Quantum corrections to the Larmor radiation formula in scalar electrodynamics
We use the semi-classical approximation in perturbative scalar quantum electrodynamics to calculate the quantum correction to the Larmor radiation formula to first order in Planck's constant in the non-relativistic approximation, choosing the initial state of the charged particle to be a momentum eigenstate. We calculate this correction in two cases: in the first case the charged particle is accelerated by a time-dependent but space-independent vector potential whereas in the second case it is accelerated by a time-independent vector potential which is a function of one spatial coordinate. We find that the corrections in these two cases are different even for a charged particle with the same classical motion. The correction in each case turns out to be non-local in time in contrast to the classical approximation.
2009-01-01
X-ray and UV-light irradiation effects on oxide superconducting thin films
International Nuclear Information System (INIS)
Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 by the irradiation. ...
[Somatic radiation risk in conventional tomography of the skull and thorax].
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769
1982-10-01
UK PubMed Central (United Kingdom)
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
2008-11-01
Terminal-differential algorithm for identification of local non homogeneity in article
International Nuclear Information System (INIS)
Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study
Somatic radiation risk in conventional tomography of the skull and thorax
Energy Technology Data Exchange (ETDEWEB)
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.
1982-10-01
Somatic radiation risk in conventional tomography of the skull and thorax
International Nuclear Information System (INIS)
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).
1982-01-01
Inhibited spontaneous emission by a Rydberg atom
Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.
1985-11-11
EPR dosimetry in chemically treated fingernails
UK PubMed Central (United Kingdom)
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
2007-08-01
International Nuclear Information System (INIS)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...
2009-10-01
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
Somatic radiation risk in X-ray diagnostics
Energy Technology Data Exchange (ETDEWEB)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
1983-12-01
Somatic radiation risk in X-ray diagnostics
International Nuclear Information System (INIS)
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
1983-01-01
Behaviour Features of the Radiative Losses of the Torsatron U-3M Plasma
International Nuclear Information System (INIS)
The total bolometrically measured plasma radiation losses on the RF heating power were found. The results of measurements demonstrate a nonmonotonic dependence of radiation losses on RF power. Namely, at low RF power levels (80...170 kW) the total radiation losses raised with increasing the RF power. However, the total radiation losses decreased sharply when RF power exceeded 200 kW (down to ?20 kW at 240 kW of RF power). Simultaneously, the intensity of impurity lines fell down significantly, whereas the average electron temperature (found from ECE measurement) increased. The authors consider that screening properties of periphery plasma give reasons for above experimental facts.
2006-01-01
Oligodendroglioma occurring after radiation therapy for pituitary adenoma
Energy Technology Data Exchange (ETDEWEB)
A 38 year old male dentist developed an oligodendroglioma of the left medial temporal lobe and parasellar region 12 years after radiotherapy with 6600 rads for acromegaly. The 30 cases of radiation-induced gliomas reported in the English literature are reviewed and analysed. The criteria for defining radiation-induced tumours of the central nervous system are proposed as follows: the tumour has a long quiescent ''latency period'', a location in the previously irradiated field, a verified histological difference from a primary condition, and does not arise from a primary condition associated with a genetic syndrome such as neurofibromatosis or tuberous sclerosis. The reported case fulfilled these criteria but appears to be the only reported radiation-induced oligodendroglioma.
1987-12-01
Detection of Free-Living Amoebae in Some Water Sources and its Control by Ultraviolet- Radiation
International Nuclear Information System (INIS)
Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for ...
Radiation damage measurements in room temperature semiconductor radiation detectors
Energy Technology Data Exchange (ETDEWEB)
The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and ...
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be ...
1995-07-20
On the space-time scales of the surface solar radiation field
Energy Technology Data Exchange (ETDEWEB)
The characteristic space-time scales of surface solar radiation fields measured by the 111-instrument ME-SONET in Oklahoma are estimated after removal of the diurnal cycle. These estimates of {open_quotes}within-day{close_quotes} are used to deduce the representativeness of surface solar radiation measurements measurement site as a function of time-averaging interval. Nomograms of the relation between point measurements and area averages are given for different space-time-averaging intervals. Examples from the nomograms show, for instance, that under conditions of low mean radiation (cloudy days), the central site point measurements are representative of a spatial area the size of a T42 GCM grid box (280 km X 280 km) if one uses hourly averages and is willing to accept a correlation of 0.45 between area average and point ...
1998-01-01
International Nuclear Information System (INIS)
Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage
Energy Technology Data Exchange (ETDEWEB)
We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al{sup 0}, Al{sup +} and Al{sup ++}). The calculations were carried for stationary plasmas, with input parameters (n{sub e} and T{sub e}) ranging respectively between 10{sup 13-18} cm{sup -3} and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to ...
2009-10-15
International Nuclear Information System (INIS)
We present a collisional-radiative approach of the theoretical analysis of laser-induced breakdown spectroscopy (LIBS) plasmas. This model, which relies on an optimized effective potential atomic structure code, was used to simulate a pure aluminum plasma. The description of aluminum involved a set of 220 atomic levels representative of three different stages of ionization (Al0, Al+ and Al++). The calculations were carried for stationary plasmas, with input parameters (ne and Te) ranging respectively between 1013-18 cm-3 and 0.3-2 eV. A comparison of our atomic data with some existing databases is made. The code was mainly developed to address the validity of the local thermodynamic equilibrium (LTE) assumption. For usual LIBS plasma parameters, we did not reveal a sizeable discrepancy of the radiative equilibrium of the plasma towards LTE. For cases where LTE was firmly believed to stand, the Boltzmann plot outputs of this ...
2009-10-01
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and ...
2008-05-01
Towards Resonant-State THz Laser Based on Strained p-Ge ...
... charge carriers in strained p-Ge in crossed electric and magnetic fields was studied by means of measurements of spontaneous radiation intensity. ...
2006-07-01
Measured Temperatures of Solid Rocket Motors Dump Stored ...
... TARGET SENSOR-MK 80 SERIES BOMBS ... 5-inch-, and 2.75-inch- diameter rocket motors that ... balance when compared to incoming solar radiation ...
1989-07-01
An integrating dosimeter for pulsed radiation
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
1983-12-01
Long-term results in 144 localized Ewing's sarcoma patients treated with combined therapy
International Nuclear Information System (INIS)
The results of 144 previously untreated cases of primary Ewing's sarcoma of bone are reported with a minimum follow-up of 5 years. This series was treated between 1972 and 1982 at Istituto Ortopedico Rizzoli with a combined therapy. The local control of the disease consisted of amputation (ten cases), resection followed by radiation therapy (35-45 Gy) (48 cases) and radiation therapy alone (40-60 Gy) (86 cases). Adjuvant chemotherapy, rigorously standardized, was performed according two different protocols: the first (85 cases treated in the period 1972-1978) consisted of vincristine (VCR) Adriamycin (doxorubicin) (ADM), and cyclophosphamide (EDX); the second (59 cases treated in the period 1979-1982) of VCR, ADM, EDX and dactinomycin (DACT). At a follow-up of 5 to 16 years (median, 9), 59 patients (41%) are continuously ...
Measuring characteristics on emissivity using infrared thermometer for RCCS
International Nuclear Information System (INIS)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while ...
2004-12-01
UK PubMed Central (United Kingdom)
AbstractBackgroundIonizing radiation (IR) initiates intracellular oxidative stress through enhanced formation of reactive oxygen species (ROS) that attack DNA leading...Full Text Available
2010-05-01
Motion management with phase-adapted 4D-optimization
UK PubMed Central (United Kingdom)
Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan....Full Text Available
2010-09-07
UK PubMed Central (United Kingdom)
Patients experiencing several cancers can be a challenge, as optimal treatment options for the different cancers might interfere with each other. In this case report, we present a woman diagnosed with...Full Text Available
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
2007-05-10
British Library Electronic Table of Contents (United Kingdom)
New ELISA assays were developed to measure immunoreactivity for XMRV. Antibody titers were measured in a cohort of prostate cancer cases and cancer free controls from the central United States. No statistically significant differences were observed in immunoreactivity between cases and controls for either the XMRV-env or the XMRV-gag antigen.
2011-01-01
Risk assessment for radiation protection purposes
International Nuclear Information System (INIS)
In defining criteria for good protection against ionizing radiation, it is important to assess quantitatively the likely risk of any radiation exposure. The 'somatic' risks to the individual result mainly from induction of cancer in the organs irradiated, and these risks can now be estimated on the basis of numerous detailed epidemiological surveys of exposed human populations. Estimates of the risk of hereditary effects, from genetic changes induced in germ cells, are based largely on the frequency with which such effects are induced in other species. In both cases the risk at very low dose can be inferred using knowledge of the way in which radiation damage is caused in tissues. Coherent systems of radiation protection are based on a restriction of doses to the whole body and to individual organs, such that the induction of cancer and genetic harm is infrequent, and the threshold ...
1980-01-01
Radial dose distribution of 6.0 MeV/n #alpha#-particle in water
International Nuclear Information System (INIS)
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the ...
2003-08-17
Energy Technology Data Exchange (ETDEWEB)
The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior ...
1987-06-15
Radioanalytical chemistry. Vol. 2
International Nuclear Information System (INIS)
This volume of the monograph covers the following topics: activation analysis, non-activation interaction analysis (elastic scattering of charged particles, absorption and backscattering of beta radiation and photons, radionuclide X-ray fluorescence analysis, thermalization, scattering and absorption of neutrons, use of ionization caused by nuclear radiation, use of ionization by alpha or beta radiation for the measurement of pressure, density and flow rate of gases), and automation in radioanalytical chemistry. (P.A.).
1989-01-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Radiation doses and somatic risk to patients during cardiac radiological procedures
International Nuclear Information System (INIS)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
2006-06-12
Investigation of radiation defects in solids using the EXAFS method
International Nuclear Information System (INIS)
The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeV electrons.
1978-02-15
Evaluation of radiation resistance of cable connector material
Energy Technology Data Exchange (ETDEWEB)
Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.
2002-10-01
Verification of electron beam therapy with storage phosphor images: Precision of field placement
Energy Technology Data Exchange (ETDEWEB)
Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron treatments should be similar to the emphasis ...
1990-04-01
Energy Technology Data Exchange (ETDEWEB)
The PuO/sub 2/ cask or SP 5320-2 and 3 cask is designed for surface shipment of americium or plutonium. The cask design was physically tested to demonstrate that it met the criteria specified in US ERDA Manual Chapter 0529, and Chapter I, Interstate Commerce Commission. The package has been assessed for transport of up to 357 grams of plutonium (403 grams PuO/sub 2/ powder) and up to 176 grams of americium (200 grams AmO/sub 2/ powder), having a maximum decay heat of 203 watts. Criticality evaluation alone would allow the shipment as Fissile Class II but the radiation level of the cask, measured at the time of shipment, may exceed 50 mrem/h at the surface and require shipment as Fissile Class III. Sample calculations address only the more restrictive of the two materials, which in most cases is /sup 238/PuO/sub 2/.
1980-05-01
International Nuclear Information System (INIS)
The Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI-2 Reactor Building during February and March 1982 and was designed to investigate the effectiveness of various surface decontamination techniques. The polar crane, D-rings, missile shields, refueling canal, fueling bridge, major equipment, floors and some walls were flushed with low pressure water. Water lances were directed manually and applied water at temperatures between ambient and 60"0C at a flow rate of about 95 liters per minute. In addition, floor surfaces on the 305-ft elevation and floor surfaces and major equipment on the 347-ft elevation were sprayed with high pressure water (floors in the Reactor Building are designated by their elevations above sea level). The water pressure in this case varied between 13.8 and 41.4 mPa and water temperature was at a maximum 60"0C. Certain surfaces were also decontaminated using either strippable coatings or a mechanical ...
1984-07-15
In response to the consultation from the National Council on Radiation Protection and Measurements (NCRP) to the International Commission on Radiological Protection (ICRP) committee 2, retention and excretion of 239Pu deposited at wound site were calculated by coupling together the proposed NCRP wound model and the current ICRP systemic model of Pu. The physicochemical forms considered were the soluble form categorized into 'Strong Retention', and the colloidal, particulate and fragmentary forms. The results are summarized as follows. If in soluble form, immediate medical intervention is needed to prevent uptake of radionuclides to body tissues, and prompt wound monitoring is essential for an accurate estimation of the initially deposited radioactivity. If in particulate form, a multi-component exponential equation leads to an overestimation of the absorption rate to blood because of significant lymph node drainage. The committed doses in the ...
2007-06-07
Emergency response preparedness for radiological accidents involving wound contamination has become more important, considering the current extending tendency in the nuclear industry related to the nuclear fuel cycle. The US National Council on Radiation Protection and Measurements (NCRP) proposed a biokinetic and dosimetric model for the intake of radionuclides through contaminated wounds in 2007. The present paper describes the implementation of this NCRP wound model for the prediction of systemic behaviour of some important radioactive elements encountered in workplaces related to the nuclear industry. The NCRP wound model was linked to the current ICRP systemic model at each blood compartment and simultaneous differential equations for the content of radioactivity in each compartment and excreta were solved with the Runge-Kutta method. The results of the calculation of wound, whole-body or specific organ retention and daily urinary or ...
2009-05-01
International Nuclear Information System (INIS)
The decay channels of the Ar 2s"-"1 and 2p"-"1 and Kr 3p"-"1 and 3d"-"1 electronic hole states have been investigated by means of photoelectron-photoion coincidence measurements following innershell ionization using synchrotron radiation. With the method of final ion-charge resolving electron spectroscopy it has become possible to disentangle different contributions to the electron spectrum and to determine the decay probabilities P(nl"-"1#->#n+) of the above-mentioned hole states (nl"-"1) to the final ionic charge states n+. A high correlation with threefold or even fourfold charged ions has been found in all cases. Possible decay routes, via cascade or direct double Auger processes, are discussed on the basis of energy-level schemes calculated with the Hartree-Fock method. Special emphasis is laid on the examination of the Kr 3p"-"1 decay process, where the two fine-structure components (j=1/2,3/2) exhibit noticeably ...
2002-04-01
Energy Technology Data Exchange (ETDEWEB)
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic ...
2000-03-01
Relationship between serum heat-stable alkaline phosphatase level and pregnancy
International Nuclear Information System (INIS)
Serum heat-stable alkaline phosphatase (HSAP) level in 649 cases of normal pregnancy and 164 cases of high-risk pregnancy is measured by radioimmunoassay (RIA). The results indicate that the HSAP level in normal pregnancy increased proportionally with gestation weeks (r = 0.9843). In 33 cases of pregnancy induced hypertension and 21 cases of intrauterine fetal growth retardation, the HSAP level is significantly low. In 7 cases of neonatal asphyxia and 26 cases of fetal distress, the HSAP level in the mother's serum is also low. In 53 cases of intrahepatic cholestasis of pregnancy, the HSAP level is similar to those of normal pregnancy. This study illustrates that HSAP RIA can play an important role in the evaluation of placental function and fetal prognosis for cases of high-risk pregnancy.
1998-01-01
Technology of iodine-131 production and its application
International Nuclear Information System (INIS)
Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid ...
Energy Technology Data Exchange (ETDEWEB)
Water vapor is well known to be a critical component in many aspects of atmospheric research, such as radiative transfer and cloud and aerosol processes. This requires both improved measurements of the columnar water vapor and its profiles in the atmosphere in a wide range of conditions, and adjustment of water vapor parameterizations in radiation codes including the perfection of spectroscopic parameters. In this paper we will present the results of comparison of our calculations and downward solar fluxes measured with Rotating Shadowband Spectroradiometer under conditions of horizontally homogeneous clouds. We also will discuss the sensitivity of atmospheric radiation characteristics to variations of water vapor in the band 940 nm: these results may be useful for development of new methods of retrieval of the total column water vapor content (WVC) in the atmosphere from data of ...
2005-03-18
International Nuclear Information System (INIS)
In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.
2008-10-15
Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge
International Nuclear Information System (INIS)
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.
Circumsolar radiation telescope
Energy Technology Data Exchange (ETDEWEB)
A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is ...
1980-01-01
International Nuclear Information System (INIS)
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
Effect of rapid thermal annealing on radiation hardening of MOS devices
International Nuclear Information System (INIS)
The influence of RTA (Rapid Thermal Anneal) treatment on MOS radiation hardness is demonstrated and compared with classical furnace treatment. In the case of the RTA, the oxide trapped charge is found to depend on: (i) the anneal temperature as expected, data are in good agreement with a recently developed model of oxygen out-diffusion; (ii) the location across the wafer with a radial dependence, results could be related to stress induced by thermal gradient.
1995-07-17
Vacuum ultraviolet radiometry of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation ...
1995-10-01
International Nuclear Information System (INIS)
A new kind of e-beam bunching enabling the production of coherent spontaneous emission (CSE) is proposed and considered. It is shown that an e-beam in passing through an undulator will induce CSE along with incoherent spontaneous radiation on the same wavelength if the e-beam transverse velocity is modulated with a spatial period twice as long as the radiation wavelength. Such angular modulated beams can be regarded as alternatives to conventionally density modulated beams for CSE production. Requirements for e-beams are similar in both cases.
1999-06-01
Radiation doses from flying through nuclear-debris clouds. Final report, 2-10 January 1985
Energy Technology Data Exchange (ETDEWEB)
Taboada et al. have recently developed a computer model to predict gamma radiation doses to aircrews flying through nuclear-debris clouds. Although the model has the advantages of taking a large number of parameters into account and using the benchmark DELFIC code to model cloud dynamics, it takes up to 20 min for a single run on a mainframe computer. Results from a number of runs have been generalized into empirical formulae. From these results it is possible to estimate worst case gamma radiation doses for complex scenarios using a hand calculator.
1986-04-01
Energy Technology Data Exchange (ETDEWEB)
Background: Despite the fact that adverse health effects are not confirmed for exposure to radiofrequency electromagnetic field (RFEMF) levels below the limit values, as defined in the guidelines of the International Commission on Non-Ionizing Radiation Protection, many persons are worried about possible adverse health effects caused by the RF-EMF emitted from mobile phone base stations, or they attribute their unspecific health complaints like headache or sleep disturbances to these fields. Method: In the framework of a cross-sectional study a questionnaire was sent to 4150 persons living in predominantly urban areas. Participants were asked whether base stations affected their health. Health complaints were measured with standardized health questionnaires for sleep disturbances, headache, health complaints and mental and physical health. 3,526 persons responded (85%) to the questionnaire and 1,808 (51%) agreed to dosimetric ...
2010-07-01
Energy Technology Data Exchange (ETDEWEB)
A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the ...
1990-01-01
A.C.R.O. activity report 1999; A.C.R.O. rapport d'activite scientifique 1999
Energy Technology Data Exchange (ETDEWEB)
The work of this association is cut according to 6 axes. Three publications: radiological quality of marine and continental waters of the Normandy coast (synthesis 1997 and 1998); preliminary study of the iodine 129 distribution in the environment of the reprocessing plant of La Hague with terrestrial moss (Homalotecium sericeum); radiological surveillance of the aquatic environment of the nuclear facilities on the area of La Hague (1997 and 1998). The second axis concerns the radiation protection with a campaign of radon measures in a school of the Vire rural district (june 1999). The third part is devoted to the radioecology with the surveillance of radioactivity in the aquatic continental environment of nuclear facilities and the radioecological surveillance (1999) of the building site of Cogema la Hague in the area of tidal range of the Moulinets cove. The fourth part concerns the radioactive waste and environment, with the study of the ...
1999-07-01
UK PubMed Central (United Kingdom)
In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available
2009-01-01
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal ...
1986-01-01
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.
1984-11-08
Energy Technology Data Exchange (ETDEWEB)
The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.
1985-10-01
International trends in radiation protection
International Nuclear Information System (INIS)
The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.
Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note
Energy Technology Data Exchange (ETDEWEB)
The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.
1986-01-01
International Nuclear Information System (INIS)
The main aim of sanitary pass-control regime is to prevent propagation of radioactive contamination outside the area of emergency-rescue works and guarantee of sanitary treatment of all persons having radioactive contamination. The paper has studied the questions of organization of sanitary pass-control regime, arrangement of sanitary treatment of the injured persons and rendering first aid in case of radioactive contamination of wounds. 5 refs.
Weakly penetrating radiation monitoring and assessment at Daya Bay Nuclear Power Plant
International Nuclear Information System (INIS)
Weakly penetrating radiation monitoring and investigating with area monitors and individual dosimeters were carried out at Daya Bay nuclear power plant during its refueling outages. This paper introduces monitoring methods, measuring results, data analysis and assessment, presents some suggestions for monitoring plan and protection measures in the future as well. (authors)
2006-05-01
Rayleigh scattering of Moessbauer radiation in hyaluronate oriented fibres
Energy Technology Data Exchange (ETDEWEB)
The Rayleigh scattering of Moessbauer radiation has been measured on highly oriented fibres of Na-hyaluronate at different hydration levels. The elastic- and-inelastic-scattering intensities, measured as a function of the scattering vector Q, have provided information on the dynamic structuring of the water molecules to the polysaccharidic chains.
1996-02-01
Energy Technology Data Exchange (ETDEWEB)
Frequency response measurements are used to determine the carrier lifetime of 1.3-..mu..m InGaAsP buried heterostructure lasers between 1 mA and threshold. The data confirm previous results on the radiative and Auger recombination coefficients and reveal the presence of a nonradiative current which dominates at low currents and contributes 4 mA at threshold.
1987-02-09
British Library Electronic Table of Contents (United Kingdom)
The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
In 2009, the Atmospheric Radiation Measurement (ARM) Program and the Climate Change Prediction Program (CCPP) have been asked to produce joint science metrics. For CCPP, the second quarter metrics are reported in Evaluation of Simulated Precipitation in CCSM3: Annual Cycle Performance Metrics at Watershed Scales. For ARM, the metrics will produce and make available new continuous time series of radiative fluxes based on one year of observations from Barrow, Alaska, during the International Polar Year and report on comparisons of observations with baseline simulations of the Community Climate System Model (CCSM).
2009-04-15
Surgical aspects of intestinal injury due to pelvic radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is ...
1985-04-01
Radiation processing of wood-plastic composites
International Nuclear Information System (INIS)
There are three main types of radiation-processed composite material derived from plastics and fibrous natural polymers. The first are the monomer-impregnated, radiation-treated wood-plastic composites (WPC). They became a commercial success in the early 1970s. More recently, work has focused on improving the WPCs by creating in them interpenetrating network (IPN) systems by the use of appropriate multifunctional oligomers and monomers. The main kinetic features of radiation-initiated chain polymerization remain applicable even in impregnated wood. The second type are the plastics filled or reinforced with dispersed wood fiber or other cellulosics (WFRP). In their case, radiation processing offers a new opportunity to apply radiation-reactive adhesion promoters between wood or cellulosic fibers and the thermoplastic matrices. The third type are the laminar ...
International Nuclear Information System (INIS)
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) ...
1988-01-01
Effect of antioxidants on aging of nuclear plant cable insulation
International Nuclear Information System (INIS)
The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants ...
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization ...
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
A representative National Survey to evaluate the exposure to natural sources of ionizing radiation in dwellings was conducted in all the 21 Italian Regions from 1989 to 1998, and the complete results are reported in this paper. Radon concentration was measured for two consecutive 6-month periods (generally covering the spring-summer and autumn-winter seasons) in one room, usually the main bedroom, of each surveyed dwelling. Validated radon concentration measurements were obtained for a total of 5631 dwellings, distributed in 232 towns (all the 50 towns with more than 100,000 inhabitants and 182 randomly sampled smaller towns). The national average, weighted by the population of each Region, of the annual radon concentration is 70Bqm{sup -3}, the geometric mean is 52Bqm{sup -3}, and the geometric standard deviation is 2.1. The fraction of dwellings with a radon concentration exceeding the reference levels of 150, 200, 400, ...
2005-11-15
Plutonium isotopes (239Pu and 238Pu, and 241Am) with a total activity of 269 kBq were accidentally deposited in a puncture wound of the right index finger of a nuclear worker at the Mayak Production Association. Tissues surrounding the wound site contaminated with radionuclides were excised 4.5 h after the injury. Residual contamination within the wound amounted to 0.05% of the initial contamination. The 10-d therapy with CaNa3-diethylene triamine pentaacetate acid (CaNa3-DTPA) was performed in parallel with in vivo measurements of the wound site and daily urine bioassays. The wound intake of radionuclides was consistent with two forms of radioactive materials detected within the wound site, i.e., soluble compounds and a large fragment, which was completely removed by excision. On day 9 after the injury, the clearance rate from the wound site was 1.8 times higher than the rate predicted by the National Council on Radiation Protection and ...
2010-10-01
Paediatric radiography - the avoidance of late radiation damage to the growing hip
Energy Technology Data Exchange (ETDEWEB)
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
1993-04-01
Identification of oxidation states of ultra-trace elements by radiation detection
International Nuclear Information System (INIS)
The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.
1989-11-01
Dynamics of spontaneous radiation of atoms scattered by a resonance standing light wave
International Nuclear Information System (INIS)
The scattering of atoms by a resonance standing light wave is considered under conditions when the lower of two resonance levels is metastable, while the upper level rapidly decays due to mainly spontaneous radiative transitions to the nonresonance levels of an atom. The diffraction scattering regime is studied, when the Rabi frequency is sufficiently high and many diffraction maxima are formed due to scattering. The dynamics of spontaneous radiation of an atom is investigated. It is shown that scattering slows down substantially the radiative decay of the atom. The regions and characteristics of the power and exponential decay are determined. The adiabatic and nonadiabatic scattering regimes are studied. It is shown that the wave packets of atoms in the metastable and resonance excited states narrow down during scattering. A limiting (minimal) size of the wave packets is found, which is achieved upon nonadiabatic ...
2003-09-01
Is energy imparted a good measure of the radiation risk associated with CT examinations
International Nuclear Information System (INIS)
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted ...
International Nuclear Information System (INIS)
Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw ...
1998-02-01
Energy Technology Data Exchange (ETDEWEB)
The authors have measured the noise of MOS transistors of the United Technology Microelectronics Center (UTMC) 1.2 [mu]m radiation hardened CMOS P-well process from the weak to moderate inversion region. The noise power spectral densities of both NMOS and PMOS devices were measured from 1 KHz to 50 MHz. The bandwidth was chosen such that the important components of the spectral densities such as the white thermal noise and the 1/f noise could be easily resolved and analyzed in detail. In this paper the effects of different device terminal DC biases and channel geometries on the noise are described.
1992-08-01
Response of a non-Hodgkin lymphoma to "6"0Co therapy monitored by 31P MRS in situ
International Nuclear Information System (INIS)
High quality "3"1P MR spectra (signal to noise ratio (S/N) approximately 18, 15 min acquisition for each spectrum) were consistently obtained with surface coils over a period of 6-week RT. Both transient and steady state alterations in metabolites in response to RT were found in this case. The transient changes occurred during the first 3 hr immediately after the 3rd fractionated RT, these changes include the transient elevation of the PCr resonance, a decrease in PDE and an increase in intracellular pH. The monitoring showed that the metabolites approached steady state approximately 2 hr after the fractionated radiation intervention, suggesting that in vivo MRS can be useful for studying the dynamics of tumor response to RT such as repair of potential lethal damage, growth delay, and reoxygenation etc. The steady-state MR spectra showed the net response to each intervention and can clinically be useful for predicting and ...
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the ...
Energy Technology Data Exchange (ETDEWEB)
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
2008-12-15
Radiation exposure to patients during hepatic interventional procedure
International Nuclear Information System (INIS)
Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)
2005-05-01
Energy Technology Data Exchange (ETDEWEB)
The clinical results of electron beam therapy using intraoral cone in 8 cases of primary and recurrence carcinoma of tongue (T1 and smaller T2) were reported. The primary and recurrence cases were 5 and 3, respectively. In the 5 cases, a total dose of 10-30 Gy external radiation therapy were combined prior to electron beam therapy. The total dose of electron beam therapy varied from 40 to 60 Gy. In all cases, tumor showed good response and disappeared clinically. Radiation stomatitis, pain of the tongue with masticatory disturbance due to tenderness were complicated in all cases. These complications gradually disappeared 2 to 6 months after treatment. However, loss of body weight and bone exposure were not recognized in any case. Intraoral-cone electron beam therapy is thought to be available and has less complications ...
1989-06-01
A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+
International Nuclear Information System (INIS)
The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).
Energy Technology Data Exchange (ETDEWEB)
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder ...
2003-03-04
International Nuclear Information System (INIS)
The Forsmark and the Laxemar investigation areas are examined by the Swedish Nuclear Fuel and Waste Management Co. for a possible construction of a deep repository for nuclear waste. In the case of a future leakage of waste, the radioactive isotopes could end up in the ecosystems above the repository. The fate of the radionuclides and their possible radiological impacts are then highly determined by ecosystem carbon cycling. An important part of the carbon cycling is the soil carbon effluxes, and in the investigation areas soil carbon effluxes have been examined with the closed chamber technique. This paper is divided into two parts. Firstly, there were problems with the equipment measuring the soil carbon dioxide efflux, and the first part is a description of the problem, how it was corrected and its possible causes. The second part is a manual in how to analyse data and calculate annual estimates of soil carbon efflux. The field ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
Population residing in the northern part of the Chelyabinsk oblast and the south eastern part of the Sverdlovsk oblast of Russia affected to accidental exposure since 1957. The territory (East Ural Radioactive Trace - EURT) was contaminated after explosion of container with highly radioactive wastes at the Mayak Production Association. Studies of health effects of exposure in the southern, head part of EURT are conducted in the Ural Research and Practical Center of Radiation Medicine (U.R.P.R.M.). In the 1990's U.R.P.C.R.M. formed a cohort of EURT within Chelyabinsk oblast (14,500 cases and 19,400 external controls). The cohort was followed in 1957-1987 and the results of the study are discussed by Crestinina et al. First results of study on exposure late health effects among rural population in the northern part of the EURT are presented in this paper. Firstly, or the period 1958-2000 a statistically significant increase in cancer ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-05-01
International Nuclear Information System (INIS)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-01-01
Measurement of liquid nitrogen level by radiation
Energy Technology Data Exchange (ETDEWEB)
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
1995-07-01
Regulatory quality assurance requirements for the operation of nuclear R and D facilities in Korea
International Nuclear Information System (INIS)
Full text: Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation. including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently. nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. All provisions on nuclear safety regulation and radiation protection are entrusted to the Atomic Energy Act(AEA). The Act is enacted as the main law concerning the safety regulation of nuclear installations, and is supplemented ...
2006-10-15
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically ...
2007-11-15
Use of high energy radiation component as a reference source for radiometric testing
International Nuclear Information System (INIS)
The possibility of providing high accuracy of absorption and albedo methods of radiometric testing due to the use of high-energy radiation component that has passed through a barrier and gone from it in the opposite direction as a reference source, is considered. It is shown that the use of high-energy component of penetrating radiation as a reference source decreases the device response to the main interference in a much larger degree than its response to the change of measured parameter. Experiments are performed using steel pipes and plates. "2"4"1Am, "1"3"7Cs and "6"0Co are used as sources.
The effect of temperature on the radiative performance of Ho-YAG thin film selective emitters
Energy Technology Data Exchange (ETDEWEB)
The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.
1995-01-01
Radiological hazards in uranium mines and a yellow-cake plant in Turkey
Energy Technology Data Exchange (ETDEWEB)
Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.
1984-06-01
Radiation-protection survey guide: fixed radiographic unit. Final report, June 1980-April 1985
Energy Technology Data Exchange (ETDEWEB)
Prior to routine use, all newly installed x-ray machines must have a radiation-protection survey by a qualified expert. The survey is an evaluation of existing or potential radiation hazards associated with the use of diagnostic x-ray equipment under specific conditions. Such evaluation includes the measurement of exposure levels in the environment as well as environmental levels arising from operation of the equipment. The survey also includes an evaluation of the safety characteristics of the x-ray unit.
1985-05-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
Energy Technology Data Exchange (ETDEWEB)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.
2001-05-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
International Nuclear Information System (INIS)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.
2001-05-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
International Nuclear Information System (INIS)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)
2002-01-01
ESR spectra of radicals of gamma-irradiated wood and cellulose
International Nuclear Information System (INIS)
Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.
Overview of bunch length measurements.
Energy Technology Data Exchange (ETDEWEB)
An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.
1999-02-19
International Nuclear Information System (INIS)
The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.
Quantum locking of mirrors in interferometric measurements
International Nuclear Information System (INIS)
We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.
2004-03-07
To the problem of the Cherenkov radiation of tachyons
International Nuclear Information System (INIS)
It is shown that the Cherenkov radiation of tachyons (CRT) in general case cannot possess axial symmetry with respect to velocity v. This implies that tachyons must be vector particles. Electric dipole is used as a vector characterising the tachyon. Formulas describing the CRT spectrum are derived taking into account the asymmetry for charged tachyon and neutral tachyon dipole with arbitrary orientation with respect to v. It is shown that both types of CRT possess the same integral characteristics. A new integral of motion specific for tachyons is found. Negative results of all attempts to detect the CRT are explained.
Spontaneous radiation and lamb shift in three-dimensional photonic crystals
Spontaneous emission in photonic crystals with anisotropic three-dimensional dispersion relation is studied. If the upper level is below a characteristic frequency omega(1), or above omega(2), or between omega(1) and omega(2), the radiation is a localized field with a frequency in the band gap, or a propagating field with a frquency in the band, or a diffusion field, respectively. An analytical expression for the Lamb shift is obtained. The Lamb shift for the current case is small compared to that in an ordinary vacuum or in one- or two-dimensional photonic crystals due to lower density of states. PMID:11017227
2000-03-01
Preparation of wood-polymer composites by using ionizing radiation
International Nuclear Information System (INIS)
Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).
1982-05-01
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
Stabilization of synchrotron radiation x-ray beam by MOSTAB
International Nuclear Information System (INIS)
Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)
2003-05-01
Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole
Energy Technology Data Exchange (ETDEWEB)
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
1996-12-31
Radiation treatment of some poultry products
International Nuclear Information System (INIS)
Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.
1988-09-26
Energy Technology Data Exchange (ETDEWEB)
It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).
1992-09-01
Energy Technology Data Exchange (ETDEWEB)
Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurement results are compared with theoretical calculations.
1984-05-25
Further means for reducing radiation dose during exposure of the pelvis in infants
International Nuclear Information System (INIS)
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
Domestic radon exposures in the UK
Energy Technology Data Exchange (ETDEWEB)
Radon in the home is the main source of exposure to ionising radiation for most people. In 1990 the National Radiological Protection Board issued revised advice to the United Kingdom Government on standards of protection against radon in the home. A description is offered of the survey work being undertaken by the Board which includes radiation measurements of thousands of homes in the United Kingdom. (author).
1991-09-01
International Nuclear Information System (INIS)
Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).
Preparation of wood-polymer composites using radiation
International Nuclear Information System (INIS)
Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there was no improvement in the mechanical properties, and using acrylamide the ...
1976-11-25
International Nuclear Information System (INIS)
Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)
1999-04-01
Metrology measurement capabilities
Energy Technology Data Exchange (ETDEWEB)
Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. ...
1997-06-01
Structural and functional aspects of radiation adrenalopathy
Energy Technology Data Exchange (ETDEWEB)
As part of a combined study of the responses of the mouse adrenal gland and kidney to X-irradiation, the weight of adrenal glands, the relative volumes of the cortex and medulla and the aldosterone output were measured at predetermined times after irradiation of the left organs only.
1986-01-01
STS-83 - Johnson Space Center - NASA
Radiation Measurement in Crew Compartment. DTO 805: .... spacecraft and aircraft propulsion, and hazardous waste disposal. ...... combustion reactions in a turbulent chemical kinetic flow reactor using laser induced fluorescence and ...
SEE Characterization of the Samsung K4F660812 DRAM ... - NEPP - NASA
the Samsung K4F660812 DRAM were measured by the JPL Radiation Effects. Group [1] . ... The Samsung K4F660812 is a 8 x 223 bit Fast Page CMOS DRAM. The two- ...
Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...
1981-01-01
Development of a phoswich detector to detect neutrons in the charged-particle mixed field
Energy Technology Data Exchange (ETDEWEB)
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been ...
1997-07-01
Ewing's sarcoma: treatment and prognosis
International Nuclear Information System (INIS)
The results of treatment of 134 cases of morphologically-verified localized Ewing's sarcoma were evaluated. A comparative analysis showed relapse-free survival to be significantly lower for radiation treatment (23 %) than for its combination with various cytostatic drugs. Two-year relapse-free survival rate was as high as 43 % in cases receiving sarcolysin or cyclophosphamide as adjuvants. This was matched by 47 % for adjuvant ardiamycin or carminomycin and 56 % for adriamycin plus cyclophosphamide and vincristine. Evaluation of long-term results of adjuvant chemotherapy showed sex, age and site involvement to be of certain prognostic value.
A case of Ewing's sarcoma treated successfully with chemotherapy and radiotherapy
International Nuclear Information System (INIS)
We encountered a case of Ewing's sarcoma. The patient was a 19 year-old girl, who visited a local physician because of pain in the left scapular region, and was referred to us. Roentgenograms of her left scapula revealed an irregular moth-eaten shadow which was suspected to be a malignant bone tumor. The histological diagnosis of Ewing's sarcoma was comfirmed by needle biopsy. The initial stage of treatment consisted of radiation therapy (6000 rads) and chemotherapy (VAC and ADR). At the end of the initial stage, the symptoms were improved, the size of the local lesion was reduced on the roentgenogram and there was no evidence of distant metastases. (author).
Thermal and radiation losses in a linear device
Energy Technology Data Exchange (ETDEWEB)
An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ...
1980-11-01
Radiative Breaking of Gauge Symmetries in the MSSM and in its Extensions
The radiative electroweak symmetry breaking, the b-\\tau Yukawa and gauge couplings unification in the MSSM and its SU(5) extensions are studied in detail. In the framework of the two-loop renormalization group equations both low- and high-energy threshold effects are included. In the case of the minimal SU(5), the values of \\alpha_s obtained are somewhat larger than the experimental average. The Peccei-Quinn version of the missing-doublet SU(5) model generally predicts smaller values of \\alpha_s and b-\\tau unification, in excellent agreement with all low energy experimental data. We also study the generation of the GUT scale through radiative corrections in the context of an R-symmetric ``flipped" SU(5) x U(1)_X model and we find that this is possible in a certain range of values of the parameter space.
1998-01-01
Preparation and applications of wood-polyester composites
International Nuclear Information System (INIS)
Optimum processing parameters were searched for the pilot-scale production of wood-polyester composites by irradiation of resin-impregnated wood material. The radiation initiation of the following systems were examined in wood and without wood matrix: methyl methacrylate, mixture of styrene and acrylonitryle, and their combination with unsaturated polyester. In the most cases the over-all rate of the complete polymerization process in wood matrix is proportional to the square root of the initiation rate. The parameters of the radiation technology of wood-polyester composites have been determined, using 260 TBq (7 kCi) "6"0Co radiation source. A pilot plant has been constructed using an underwater irradiation system of 1.85 PBq (50 kCi) "6"0Co. The successful production rate of 200 kg wood-polyester composite per day, as well as the application tests have demonstrated the technical feasibility of this ...
1982-01-01
Modelling of density limit phenomena in toroidal helical plasmas
Energy Technology Data Exchange (ETDEWEB)
The physics of density limit phenomena in toroidal helical plasmas based on an analytic point model of toroidal plasmas is discussed. The combined mechanism of the transport and radiation loss of energy is analyzed, and the achievable density is derived. A scaling law of the density limit is discussed. The dependence of the critical density on the heating power, magnetic field, plasma size and safety factor in the case of L-mode energy confinement is explained. The dynamic evolution of the plasma energy and radiation loss is discussed. Assuming a simple model of density evolution, of a sudden loss of density if the temperature becomes lower than critical value, then a limit cycle oscillation is shown to occur. A condition that divides the limit cycle oscillation and the complete radiation collapse is discussed. This model seems to explain the density limit oscillation that has been observed on the W7-AS ...
2000-03-01
Chemistry and technology of radiation processed composite materials
International Nuclear Information System (INIS)
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...
1984-10-01
Chemistry and technology of radiation processed composite materials
International Nuclear Information System (INIS)
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...
1984-10-01
Secondary hazards of high power laser beam welding
International Nuclear Information System (INIS)
Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)
1996-01-01
Forward directed Smith-Purcell radiation from relativistic electrons
International Nuclear Information System (INIS)
The requirements for the generation of forward directed Smith-Purcell emission from relativistic electrons are introduced, and the first experimental evidence of this phenomenon is presented. The experiments were conducted with a 2.8 MeV/c electron beam interacting with a 1 cm period grating. Radiation emitted in two bands with wavelengths ranging from 600 to 650 #mu#m and 1.2 to 1.7 mm were measured. Grating period to wavelength ratios were as high as 16. The measured intensities are higher than that predicted by incoherent emission.
Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements
International Nuclear Information System (INIS)
A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.
1976-08-11
The preliminary success of ALARA implementation in Daya Bay NPP
International Nuclear Information System (INIS)
Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant procedures, ALARA coordination organization on plant level and for ...
2000-05-01
Energy Technology Data Exchange (ETDEWEB)
Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus of anal sphincter.
1982-09-01
Environmental impact assessment around TRIGA research reactor
International Nuclear Information System (INIS)
Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by radioactive materials could be ignored in the ...
1985-04-01
Energy Technology Data Exchange (ETDEWEB)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product ...
1995-12-31
Measurement of magnetic fields in the Area Metropolitana
International Nuclear Information System (INIS)
The operation and proper handling of equipment for measuring EMR-300 electromagnetic waves are studied and apply that knowledge to determine which areas of the metropolitan area are mostly affected by exposure to the emission of radiation. This team is able to measure magnetic field strength, electric field strength and power density, also can measure the most important parameters in a simple manner. International standards provide maximum values for these parameters that limit human exposure to such radiation. These standards are based on epidemiological several and laboratory that have been carried out in order to determine in which circumstances a biological entity is exposed to a level of radiation that can cause harm to their health. It focuses on measuring the level of radiation in certain areas of interest, which ...
International Nuclear Information System (INIS)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-15
Radiation hazard control report
Energy Technology Data Exchange (ETDEWEB)
The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.
1982-12-01
Pulse source of electron and X-ray radiations of subnanosecond duration
International Nuclear Information System (INIS)
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
Effect of decrease of molybdenum radiation hardening at high energy proton irradiation
International Nuclear Information System (INIS)
By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.
1990-05-22
Coherent spontaneous radiation from highly bunched electron beams
International Nuclear Information System (INIS)
Coherent spontaneous radiation has now been observed in several FELs, and is a subject of great importance to the design of self-amplified spontaneous emission (SASE) devices. We report observations of coherent spontaneous radiation in both FIREFLY and the mid-infrared FEL at the Stanford Picosecond FEL Center. Coherent emission has been observed at wavelengths as short as 5 microns, and enhancement over incoherent levels by as much as a factor of 4x10"4 has been observed at longer wavelengths. The latter behavior was observed at 45 microns in FIREFLY with short bunches produced by off-peak acceleration and dispersive compression. We present temporal measurements of the highly bunched electron distributions responsible for the large enhancements, using both transition radiation and energy-phase techniques.
1995-08-21
Valence mixing in rare earth compounds
International Nuclear Information System (INIS)
The concepts of ''fast'' and ''slow'' time scale valence measurements are emphasized by a comparison of L/sub III/ absorption and Mossbauer effect measurements on the temperature induced valence change in EuPd/sub 2/Si/sub 2/. Further the authors show how synchrotron radiation based L/sub III/ measurements of the Ce-valence state can be used to demonstrate electronic structure trends under wide changes in chemical environment. The purpose of this paper is to provide an introduction to researchers in the People's Republic of China to the field of mixed valent rate earth compounds. They hope to illustrate some of the basic concepts in this field, how the field is contributing to the overall insight into the chemical physics of solids and finally how synchrotron radiation measurements in particular are playing a key role in this field.
Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this ...
1982-01-01
Photoluminescence in large fluence radiation irradiated space silicon solar cells
Energy Technology Data Exchange (ETDEWEB)
Photoluminescence spectroscopy measurements were carried out for silicon 50{mu}m BSFR space solar cells irradiated with 1MeV electrons with a fluence exceeding 1 x 10{sup 16} e/cm{sup 2} and 10MeV protons with a fluence exceeding 1 x 10{sup 13} p/cm{sup 2}. The results were compared with the previous result performed in a relative low fluence region, and the radiation-induced defects which cause anomalous degradation of the cell performance in such large fluence regions were discussed. As far as we know, this is the first report which presents the PL measurement results at 4.2K of the large fluence radiation irradiated silicon solar cells. (author)
1997-03-01
Normalized noise power spectrum of full field digital mammography detector system
International Nuclear Information System (INIS)
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
Normalized Noise Power Spectrum of Full Field Digital Mammography System
International Nuclear Information System (INIS)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
2010-01-05
Irradiation effects on the electrochemistry and corrosion resistance of stainless steel
International Nuclear Information System (INIS)
Nickel ion radiation at 500 C was shown to have a strong effect on the surface electrochemistry and intergranular corrosion (IGC) of stainless steel (SS). Measured current densities in a 1 N sulfuric acid solution at room temperature were increased at active-passive, passive, and transpassive potentials. Radiation effects on the current decay behavior and susecptibility to IGC were similar for a fine-grained (FG) S alloy and for a very large-grained (LG) SS. Radiation-induced segregation (RIS) at the surface was believed to promote higher currents at short times, whereas segregation at grain boundaries was responsible for IG attack. Analytical electron microscopy (AEM) measurements revealed chromium and iron depletion plus Ni and silicon enrichment at grain boundaries in irradiated specimens. Si enhanced dissolution at transpassive potentials, whereas Cr depletion did the same at ...
1995-01-01
Detached divertor plasmas in JET
Energy Technology Data Exchange (ETDEWEB)
In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.
1994-07-01
Energy Technology Data Exchange (ETDEWEB)
This section contains the detailed measured impact results and market segment data for each DSM case examined for this building type. A complete index of all base and measure cases defined for this building type is shown first. This index represents an expansion of the base and measure matrix presented in Table 1 (residential) or Table 2 (commercial) for the applicable sector. Following this index, a summary report sheet is provided for each DSM measure case in the order shown in the index. The summary report sheet contains a host of information and selected graphs which define and depict the measure impacts and outline the market segment data assumptions utilized for each case in the DBEDT DSM Forecasting models. The variables and figures included in the summary report sheet are described. Numerous ...
1995-04-01
Energy Technology Data Exchange (ETDEWEB)
This section contains the detailed measured impact results and market segment data for each DSM case examined for this building type. A complete index of all base and measure cases defined for this building type is shown first. This index represents an expansion of the base and measure matrix presented in Table 1 (residential) or Table 2 (commercial) for the applicable sector. Following this index, a summary report sheet is provided for each DSM measure case in the order shown in the index. The summary report sheet contains a host of information and selected graphs which define and depict the measure impacts and outline the market segment data assumptions utilized for each case in the DBEDT DSM Forecasting models. The variables and figures included in the summary report sheet are described. Numerous ...
1995-04-01
Hearing loss in Turner syndrome
British Library Electronic Table of Contents (United Kingdom)
ObjectiveTo address the characteristics of hearing loss in patients with Turner syndrome (TS), we evaluated hearing levels of patients with TS and analyzed causative factors.Study designThirty-three patients with TS (8 to 40 years of age) were studied through the use of audiological measurements, and causative factors were explored.ResultsTwenty cases (35 of 66 ears tested) showed high-frequency (8 kHz) sensory neural hearing loss (HFQ-SNHL). Fifteen cases (26 ears) and 15 cases (24 ears) of the impaired 20 cases were unresponsive to distortion-product otoacoustic emissions and transient-evoked otoacoustic emissions, respectively. HFQ-SNHL showed little relation to the history of middle ear infection and puberty, although middle ear infections were seen in 11 of the 20 cases. The hearing t...
2006-01-01
The electron cyclotron absorption diagnostic for the JET pumped divertor plasma
International Nuclear Information System (INIS)
We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may ...
1993-03-01
Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation
International Nuclear Information System (INIS)
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, ...
1992-10-25
International Nuclear Information System (INIS)
The neutron capture cross sections of the stable molybdenum isotopes have been measured with high energy resolution (#DELTA#E/E < approximately 0.2%), between 3 and 90 keV neutron energy, at the 40 m station of ORELA. Average resonance parameters are extracted for s- and p-wave resonances. The s-wave neutron strength function is close to 0.5x10"-"4 for all isotopes, but the p-wave strength function exhibits a well defined peak near A approximately 95. Both s- and p-wave radiative widths decrease markedly as further neutrons are added to the closed shell. The p-wave radiative widths are generally greater than the s-wave widths showing the presence of non-statistical #gamma#-decay mechanisms. Valence neutron theory fails to explain the magnitude of the p- to s-wave radiative width disparity and doorway state processes are invoked. In particular, the data for "9"8Mo appear to violate the usual valence ...
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber ...
2007-08-21
International Nuclear Information System (INIS)
The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.
Dimensional metrology and positioning operations are used in many fields of particle accelerator projects. This lecture gives the basic tools to designers in the field of measure by analysing the spatial layout of measurement systems since it is central to dimensional metrology as well as positioning operations. In a second part, a case study dedicated to a synchrotron storage ring is proposed from the detection of the magnetic centre of quadrupoles to the orbit definition of the ring.
2010-01-01
International Nuclear Information System (INIS)
The Chernobyl reactor accident has pronupted all European countries to rehabilitate their existing measurement and monitoring systems and to design and erect new ones. These systems are meant to ensure a rapid overview on the situation in case of an accident to adopt suitable actions for protection or prevention. 6 papers report on the state of such measurement systems in Europe, inparticular those in France (TELERAY), in Germany (IMIS) and in Switzerland (RADAIR). The IMIS-system is discussed for its extension to Eastern Germany. (HP).
Precision Measurement of the Undulator K Parameter using Spontaneous Radiation
Energy Technology Data Exchange (ETDEWEB)
Obtaining precise values of the undulator parameter, K, is critical for producing high-gain FEL radiation. At the LCLS [1], where the FEL wavelength reaches down to 1.5 {angstrom}, the relative precision of K must satisfy ({Delta}K/K){sub rms} {approx}< 0.015% over the full length of the undulator. Transverse misalignments, construction errors, radiation damage, and temperature variations all contribute to errors in the mean K values among the undulator segments. It is therefore important to develop some means to measure relative K values, after installation and alignment. We propose a method using the angle-integrated spontaneous radiation spectrum of two nearby undulator segments, and the natural shot-to-shot energy jitter of the electron beam. Simulation of this scheme is presented using both ideal and measured undulator fields. By ...
2007-04-17
Characterization of Radiation Instruments at the Summit of Mt. Fuji
International Nuclear Information System (INIS)
The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically ...
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
We describe exact cosmological solutions with rotation and expansion in the low-energy effective string theory. These models are spatially homogeneous (closed Bianchi type IX) and they belong to the family of shear-free metrics which are causal (no closed timelike curves are allowed), admit no parallax effects and do not disturb the isotropy of the background radiation. The dilaton and the axion fields are nontrivial, in general, and we consider both cases with and without the central charge (effective cosmological constant)
2003-03-21
International Nuclear Information System (INIS)
We describe exact cosmological solutions with rotation and expansion in the low-energy effective string theory. These models are spatially homogeneous (closed Bianchi type IX) and they belong to the family of shear-free metrics which are causal (no closed timelike curves are allowed), admit no parallax effects and do not disturb the isotropy of the background radiation. The dilaton and the axion fields are nontrivial, in general, and we consider both cases with and without the central charge (effective cosmological constant).
2003-03-21
Energy Technology Data Exchange (ETDEWEB)
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
1992-06-12
Gene rearrangement and radiation carcinogenesis
International Nuclear Information System (INIS)
The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect radiation ...
1993-11-01
Fluctuations of the energy of Stokes pulses of resonance coherent SRS
International Nuclear Information System (INIS)
An analytic solution is obtained for the equations of resonance coherent SRS by neglecting the population of the final level of the Raman transition for the systems with the active-medium length that is smaller than the wavelength of the incident light. For the extended systems, a numerical solution is obtained. The energy distribution of the Stokes pulses is found. The large-scale (about 100%) fluctuations of the Stokes radiation energy were observed in the case of unsaturated amplified spontaneous emission. (nonlinear optical phenomena)
2000-11-30
International Nuclear Information System (INIS)
To be able to carry out review functions regulatory authorities must be able to make critical evaluations of proponent's safety cases. In Sweden the Swedish Radiation Safety Authority aims to have in place its own suite of performance assessment tools. This paper looks at the role and application of a regulator's models to important features of current modelling in a proponent's performance assessment. (authors)
Bullous pemphigoid after radiation therapy
Energy Technology Data Exchange (ETDEWEB)
Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.
1988-02-01
International Nuclear Information System (INIS)
Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer ...
2010-01-01
Computed radiography for major airway in pediatrics
International Nuclear Information System (INIS)
This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to ...
1986-01-01
International Nuclear Information System (INIS)
Studies were conducted on mating behaviour and reproductive performance of a) Earias vittella (F.) males rendered sterile by exposing them to 300 Gy gamma rays and b) F_1 sterile males obtained by exposing parent male to 100 Gy gamma rays. For the study, males were allowed only one mating with a normal female. Results revealed that premating period, period in copula and per cent insects mating were not adversely affected in case of both types of sterile males and fecundity also remained unaffected. However, in both types of sterile males, incidence of spermatophore transfer without sperm was very large and such an occurrence (including reduced spermatophore transfer) was significantly higher in case of radiation sterilized males compared to the F_1 sterile males. Inability to produce and transfer spermatophore and/or sperm appeared to be a major cause behind the reduced mating competitiveness of both types of males. ...
Acute myelogenous leukemia following chemotherapy and radiation for rectal cancer
Energy Technology Data Exchange (ETDEWEB)
In August 1982, a 44-year-old man was diagnosed as having rectal cancer, histologically diagnosed as well differentiated adenocarcinoma, and abdominoperineal resection and colostomy were performed. Postoperatively, he received chemotherapy with mitomycin C up to a total dose of 100 mg. In September 1986, lung metastasis occurred and he was treated with a combination chemotherapy consisting of cisplatin, pirarubicin and 5-fluorouracil. In the following year, radiation treatment (total: 6900 rad) was given for a recurrent pelvic lesion. Peripheral blood on April 30, 1988, showed anemia, thrombocytopenia and appearance of myeloblasts, and a diagnosis of acute myelogenous leukemia (FAB: M1) was made. Combination chemotherapy (including aclarubicin, vincristine, behenoyl ara-C, daunorubicin, 6-mercaptopurine, cytarabine, etoposide and prednisolone) failed to induce remission and the patient died in June 1988. This case was thought to be one of ...
1989-03-01
Concepts in radiation protection
International Nuclear Information System (INIS)
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the dose limit diminished ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
The present study treats only the collective risk of ex-utero leukaemia associated with the routine releases of the nuclear industrial installations of the North Cotentin (0.0009 cases over the considered period) the uncertainty on the contribution to the collective risk of the incidents and the accidents of the nuclear installations (notably the drilling of the pipe of release in sea arisen in 1979-1980 and the fire of the waste silo on January 6. 1981, for the reprocessing plant of La Hague has not been considered. Only 45% of the risk are taken into account by the study. Every calculated value remains very inferior to the number of leukemia cases observed (4 cases observed for two expected cases) and to the risk of radioinduced leukemia any merged exposure sources, that is to say 0.84 cases. It appears thus not very probable that the nuclear installations of the North - Cotentin ...
2003-03-15
Local control and sequelae following irradiation of Ewing's sarcoma
International Nuclear Information System (INIS)
135 patients with histologically proven Ewing's sarcoma, treated at the Institute Gustave Roussy between 1960-1974 were reviewed in order to establish the effectiveness and the complications associated with radiotherapy. In 133 patients, a dose of at least 60 Gy for long bones, 55 Gy for flat bones and 45 Gy for vertebrae was given. 26 major complications (of which more than one occured in certain patients) were observed: 12 cases of growth retardation, loss of joint function in 7 cases, 3 fractures, 2 osteonecroses, 2 cases of delayed healing, one massive soft tissue fibrosis, 1 abdominocutaneous fistula, 2 cases of symptomatic pulmonary fibrosis with associated infection, 2 cases of radiation enteropathy, 2 of mammary hypoplasia and 1 osteosarcoma developing in an irradiated zone. These complications necessitated 12 surgical interventions, including 4 ...
Energy Technology Data Exchange (ETDEWEB)
In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the whole target volume. Therefore, in the ...
2005-12-21
International Nuclear Information System (INIS)
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to ...
2007-05-01
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
International Nuclear Information System (INIS)
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for inhomogeneous lung/water, the lung ...
2004-02-01
Energy Technology Data Exchange (ETDEWEB)
Epidemiological studies could not show an association between ionising radiation of nuclear power stations in routine operation and the incidence of childhood cancer, yet. The following report presents a case control study conducted by the German Childhood Cancer Registry since autumn 2003. All children in the study region, who were diagnosed with cancer between 1980 and 2003 at an age below five are included. In the first part of the study we investigate whether children with cancer (cases) lived closer to the respective nuclear power stations compared to random children without cancer (controls). In the second part, for a subgroup of cases and controls we conduct computer assisted telephone interviews regarding confounders possibly associated with the exposure of ionising radiation and childhood cancer. Results are expected by the end of 2006. (orig.)
2006-07-01
Test firings of 120-mm rounds were performed to characterize effects due to the combustible cartridge cases used. Comparisons were made between measured ballistic parameters, especially gas pressures, and those predicted by computerized simulation calcula...
1988-01-01
Relativistic Feynman-type integrals
Energy Technology Data Exchange (ETDEWEB)
It is shown that within the framework of the Kershaw stochastic model generalized by the author to the relativistic case a Feynman-type process may be constructed which can formally be understood as a diffusion phenomenon in Euclidean space. This makes it possible to introduce a real probability measure in the scheme of quantum mechanics proposed by Feynman.
1980-05-01
UK PubMed Central (United Kingdom)
Erythrocyte transketolase activity and the effect of adding thiamine pyrophosphate (% thiamine pyrophosphate effect) were measured in 111 subjects suspected to suffer from Leigh's disease (subacute...Full Text Available
1980-10-01
Contents: Introduction; Design Criteria for a Green Building; Comparison of Energy Efficiency Measures; Whole House Energy Efficiency; Built Examples of Energy Efficient Houses; and Product Energy of Building Elements.
1993-01-01
Combustion Mechanisms of 25MM Combustible Cartridge.
The structural features of 25mm combustible cartridge cases, manufactured for this program and having nitrocellulose/resin/fiber ratios of 85/10/5, 80/15/5, 75/20/5 and 75/10/15, were characterized through permeability measurements, respectively, about 10...
1973-01-01
Cavity detection by the electric method: the 3-dimensional case
Energy Technology Data Exchange (ETDEWEB)
In this paper the authors prove a uniqueness theorem for the electric detection of cavities in a three dimensional solid from Cauchy data measured on the surface. The cavities, finite in number, are assumed to be insulating. The surfaces of the cavities are assumed to be smooth on the complement of a set that is, in some sense, negligible. (orig.)
2004-02-01
Heterophyle antibodies causing false positive radio-immunoassay results a case report
International Nuclear Information System (INIS)
A case report of falsely elevated serum hormone values measured by radio-immunoassay (RIA) is described. The radio-immunoassays concerned have a first antibody raised in rabbits and mostly a separation technique based on a second antibody-solid phase system. The presence of heterophyle (anti-rabbit) antibodies in patients' serum is proved.
Energy Technology Data Exchange (ETDEWEB)
An electrical circuit testing device is provided, comprising a case, a digital voltage level testing circuit with a display means, a switch to initiate measurement using the device, a non-shorting switching means for selecting pre-determined electrical wiring configurations to be tested in an outlet, a terminal block, a five-pole electrical plug mounted on the case surface and a set of adapters that can be used for various multiple-pronged electrical outlet configurations for voltages from 100 600 VAC from 50 100 Hz.
2006-04-18
Energy Technology Data Exchange (ETDEWEB)
This paper presents the experimental measurements of the transmittivity of commercial grade stearic acid. The effects of temperature and thickness on transmittance have been studied. The study indicates that the effect of temperature on the transmittance of stearic acid in the liquid phase is not significant. However, it is highly dependent on temperature during the solidification process. Because of its low thermal conductivity and high transmittivity, it can be used as a transparent insulating material. (Author)
1999-12-01
Gamma absorption determination of concentration in a three-component mixture
International Nuclear Information System (INIS)
A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.
Estimation of errors provided with dead times of roentgen digital tomography
International Nuclear Information System (INIS)
Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained
Energy Technology Data Exchange (ETDEWEB)
There are clearly identified scientific requirements for continuous profiling of atmospheric water vapor at the Department of Energy, Atmospheric Radiation Measurement program, Southern Great Plains CART (Cloud and Radiation Testbed) site in northern Oklahoma. Research conducted at several laboratories has demonstrated the suitability of Raman lidar for providing measurements that are an excellent match to those requirements. We have developed and installed a ruggedized Raman lidar system that resides permanently at the CART site, and that is computer automated to eliminate the requirements for operator interaction. In addition to the design goal of profiling water vapor through most of the troposphere during nighttime and through the boundary layer during daytime, the lidar provides quantitative characterizations of aerosols and clouds, including depolarization measurements for ...
1997-12-31
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Distributed radiation protection console system
International Nuclear Information System (INIS)
Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the ...
2004-02-01
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and ...
1996-12-01
Reduced levels of MMP-2 and TIMP-1 in dyssegmental dysplasia.
Matrix metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs) were measured in a mild case of dyssegmental dysplasia. X-ray pictures of a female baby born vaginally at 39 weeks of gestation showed short, bent, dumbbell-shaped long bones of the limbs and profound dyssegmental ossification in the spine, findings characteristic of dyssegmental dysplasia. When the levels of MMP-1, MMP-2, MMP-9, TIMP-1, and TIMP-2 were measured, the levels of MMP-2 and TIMP-1 were significantly reduced. This case might provide a clue to disclose the etiology of dyssegmental dysplasia. PMID:12568417
2003-02-01
Energy Technology Data Exchange (ETDEWEB)
This review of methods and designs of transducers for nondestructive determination of the magnitude and nature of the anisotropy of magnetic properties (permeability, induction, coercive force, energy loss due to magnetization reversal) in local portions of ferromagnetic sheet and, in some cases, in individual parts of products. The need to measure the anisotropy is considered for two angles: for the case when the anisotropy is due to the crystallographic texture and determines the main operating characteristics of widely used sheet such as electrical steel and automobile body sheet, and for crystallographically isotropic materials, in which the anisotropy of magnetic properties as a result of mechanical stresses is a measure for determining the internal stresses.
1995-04-01
Energy Technology Data Exchange (ETDEWEB)
Two local repair procedures, one without (9) and the other with (14) a bulbocavernosus muscle graft were performed on 20 patients with a radiation induced rectovaginal fistula. Four patients had two procedures successively. The initial success rate of both procedures was 7/9 and 14/14 respectively. Though the initial result of the bulbocavernosus graft was obviously better, in many of the local repair procedures, subclinical radiation damage progressed, resulting in recurrence of rectovaginal fistula (5), rectovesical fistula (4), pararectal abscess (2) etc. After a mean follow up of around 10 years, the success rate of fistula repair decreased to 5/9 and 13/14 and only 2/9 and 6/14 finally remained without a colostomy. A local repair operation should be restricted to carefully selected cases. The musculus gracilis is proposed as a better vascular graft. If the general condition of the patient does not allow more aggressive ...
1988-04-01
Low dose effects - is the fear more dangerous than the radiation?
Energy Technology Data Exchange (ETDEWEB)
The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the Linear or Quadratic Linear Hypothesis. ...
1996-01-01
Improvement of wood quality used in Syria by irradiation polymerization
International Nuclear Information System (INIS)
Wood plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, and with Okoume (aucoumea klaineana pierre) imported to Syria in large quantities. Three monomer systems; acrylamide, butylmethacrylate, and styrene were used. polymerization was induced at various radiation doses (10, 20, and 30 kGy) to study the role of radiation doses using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength or tensile strength of the obtained wood polymer composites (WPC) were studied. The effect of the additives, sulfuric acid (H"+), N-vinyl pyrrolidone (NVP), trimethyolpropane triacrylate (TMPTA), urea (U), lithium nitrate (LiNo_3), copper sulfate (CuSO_4) and co-additives on monomer system polymerization were also investigated. Methanol, water and water/methanol mixtures were used as the swelling agents. In general, the use of additives and ...
2010-04-01
Bevacizumab as a treatment option for radiation-induced cerebral necrosis
International Nuclear Information System (INIS)
Radiation necrosis of normal CNS tissue represents one of the main risk factors of brain irradiation, occurring more frequently and earlier at higher total doses and higher doses per fraction. At present, it is believed that the necrosis results due to increasing capillary permeability caused by cytokine release leading to extracellular edema. This process is sustained by endothelial dysfunction, tissue hypoxia, and subsequent necrosis. Consequently, blocking the vascular endothelial growth factor (VEGF) at an early stage could be an option to reduce the development of radiation necrosis by decreasing the vascular permeability. This might help to reverse the pathological mechanisms, improve the symptoms and prevent further progression. A patient with radiation-induced necrosis was treated with an anti-VEGF antibody (bevacizumab), in whom neurologic signs and symptoms improved in accordance with a decrease in T1-weighted ...
2011-02-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been ...
1996-12-31
Microclimatic conditions at the external surface of building envelopes
Energy Technology Data Exchange (ETDEWEB)
The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat ...
1998-12-31
The electrical measurement of AC losses in a three-phase tri-axial superconducting cable
International Nuclear Information System (INIS)
In a three-phase tri-axial cable, the magnetic interaction between the phases makes the loss measurement by an electromagnetic method very complex. We developed the theoretical background showing that three-phase AC loss measurements by the electromagnetic method are, in principle, possible. We then implemented this theory in practical measurements on a 3 m long, tri-axial cable fabricated from RABiTS (rolling-assisted biaxially textured substrate) coated conductor. Initially, the proposed measurement technique was implemented in the simpler cases when the three cable phases are 180"0 out of phase, i.e. (0"0, 180"0, 360"0) or (0"0, 360"0, 180"0) rather than (0"0, 120"0, 240"0) as in a traditional three-phase system. For these cases, the currents in the phases are either in phase (360"0 phase difference) or anti-phase (180"0 phase difference). These are ...
2010-09-01
Ionizing radiation alters beta-endorphin-like immunoreactivity in brain but not blood
Energy Technology Data Exchange (ETDEWEB)
Previous behavioral and pharmacological studies have implicated endorphins in radiation-induced locomotor hyperactivity of the C57BL/6J mouse. However, the endogenous opiate(s) responsible for this behavioral change have not been identified. The present study measured beta-endorphin-like immunoreactivity (beta-END-LI) in brain, blood, and combined brain and pituitary samples from irradiated and sham-irradiated C57BL/6J mice. After radiation exposure, levels of beta-END-LI decreased significantly in the brain. A similar, but not statistically significant, decline was measured in combined brain and pituitary samples. Concentrations of blood beta-END-LI were not changed by irradiation. These radiogenic changes in beta-END-LI are in some ways similar to those observed after other stresses. However, radiation-induced locomotor hyperactivity may be mediated more by alterations of ...
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
Safety standards for exposure to radiofrequency radiation must be based upon biologic consequences of exposure to such environments. Behavioral-based measures are considered to be the most-sensitive indices of biological effects. Current safety guidelines are based upon average power density and may not be relevant to the high-peak-power, short pulse width microwave radiation produced by newly developed high peak power microwave sources. The effects of exposure to high-peak-power radiation on reflexive responding and motor function in Fischer 344/N rats were assessed by measuring startle and general activity, and disruption of on-going performance of a rotarod task, respectively. The emitter used was the TEMPO repeat pulse axially extracted vircator. Exposure to single pulses resulted in significant startle responses. Exposure to 1 pps for 10 s produced significant alterations in ...
1988-03-01
Results of electron beam therapy using intra-oral cone for carcinoma of the oral tongue
Energy Technology Data Exchange (ETDEWEB)
Retrospective analyses were performed to evaluate the therapeutic efficacy of intra-oral cone (IOC) radiation therapy for carcinoma of the oral tongue, especially about its faculty of local control and complications. Thirty-nine patients with squamous cell carcinoma of the oral tongue were treated with IOC radiation therapy alone or in combination with external irradiation. IOC radiation therapy was given not only for T1 and T2, but also for T3 tumors. Hypofractionation was used for IOC radiation therapy. The 2 year local control rates, including surgical salvage, for T1, T2, T3 and T4 were 100%, 73.3%, 40% and 0%, respectively. The 5 year actuarial survival rates for Stage I, II, III and IV were 100%, 65.3%, 35.4% and 0%, respectively. The incidences of radiation complications, i.e. soft tissue ulceration and osteoradionecrosis, were 42.9% and 2.9%, respectively. It is suggested ...
1992-07-01
International Nuclear Information System (INIS)
A case-control study on lung cancer and radon exposure in dwellings has been carried out in Lazio, a high indoor radon region of Central Italy. A total of about 400 cases and 400 controls were recruited and radon concentration was measured in a total of about 1850 dwellings. In each dwelling, radon concentration measurement devices were placed in both the main bedroom and living room for two consecutive six-month periods. Each radon device, enclosed in a sealed polyethylene bag, contains two LR 115 detectors, each being covered by a thin absorber to reduce the alpha-energy within the detector sensitive range. A quality assurance program, described in this paper, was applied in order to reduce radon concentration measurement uncertainty, which have a significant impact on the results of an epidemiological study. The reported internal quality control and intercomparison results are ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...
2004-07-01
Feasibility of optical sensing for robotics in highly radioactive environments
International Nuclear Information System (INIS)
The application of robotics for repair, refurbishing or dismantling of nuclear installations implies eventually severe radiation resistance requirements on embarked components and subsystems. This is particularly critical when optical sensing is considered. Optoelectronic components and optical fibers are indeed quite sensitive to radiation, and without special design are rapidly out-of-operation in such an environment. This paper reports the results of a series of #gamma# irradiation experiments on such devices, and identify their behavior under radiation. Test results show that carefully selected optical fibers can keep their radiation induced attenuation lower than 0.3 dB/m even up to a total dose of 10 MGy. Temperature annealing can even lower this attenuation down to 0.1 dB/m. On the other hand, commercially available light emitting diodes and photodiodes present attenuations figures up to 15 dB, ...
1992-10-25
Tritium monitor with improved gamma-ray discrimination
Energy Technology Data Exchange (ETDEWEB)
Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.
1985-01-01
Neutron resonances in /sup 100/Mo and valence neutron capture
Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.
1979-07-01
FFTF shield and gamma ray measurements
Energy Technology Data Exchange (ETDEWEB)
Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.
1984-08-01
Environmental Measurements Laboratory fiscal year 1998: Accomplishments and technical activities
Energy Technology Data Exchange (ETDEWEB)
The Environmental Measurements Laboratory (EML) is government-owned, government-operated, and programmatically under the DOE Office of Environmental Management. The Laboratory is administered by the Chicago Operations Office. EML provides program management, technical assistance and data quality assurance for measurements of radiation and radioactivity relating to environmental restoration, global nuclear nonproliferation, and other priority issues for the Department of Energy, as well as for other government, national, and international organizations. This report presents the technical activities and accomplishments of EML for Fiscal Year 1998.
1999-01-01
Si-JFET devices and related noise behavior under irradiation
Energy Technology Data Exchange (ETDEWEB)
Monolithic N-channel junction field effect transistors (NJFETs) dc characteristics, small signal parameters and noise have been studied from 300 K down to cryogenic temperatures before and after irradiation with {sup 60}Co {gamma}-rays and fast neutrons (1 MeV). Radiation induced effects on dc parameters and noise are reviewed. Noise spectral density measurements performed at various temperatures have shown that the radiation induces a noise increase which is temperature and frequency dependent. (orig.). 14 refs.
1998-02-01
Radiolysis of neutron irradiated lithium solutions
International Nuclear Information System (INIS)
In the Aqueous Self-Cooled Blanket (ASCB) concept, an aqueous "6Li solution in a metallic structure is used as a shielding-breeding blanket for fusion reactors. The experimental results of this study indicate that the radiolytic gas production in an ASCB will be proportional to the absorbed radiation energy. The observed radiation chemical yields allow the preliminary estimation of the radiolysis effects for a specific ASCB design. Contrary to the theoretical predictions, the use of hydrogen as a cover gas at up to 1 MPa had no measurable effect on the radiolytic gas production. Probably it will thus not be possible to suppress the radiolytic decomposition of a low-pressure ASCB by the addition of hydrogen. Catalytic recombination will be required. (orig.).
Radiation hardness of plastic scintillating fiber
International Nuclear Information System (INIS)
We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
Radiation exposure of patients and operators during interventional radiology
International Nuclear Information System (INIS)
Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
This document is a progress report to the USDOE Atmospheric Radiation and Measurement Program (ARM). The overall project goal is to relate subgrid-cumulus-cloud formation, coverage, and population characteristics to statistical properties of surface-layer air, which in turn are modulated by heterogeneous land-usage within GCM-grid-box-size regions. The motivation is to improve the understanding and prediction of climate change by more accurately describing radiative and cloud processes.
1993-08-27
Palliation of radiation-related mucositis
Energy Technology Data Exchange (ETDEWEB)
Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.
1990-01-01
Measurement of stress in materials using chromium K/sub. beta. / radiation
Energy Technology Data Exchange (ETDEWEB)
Bragg peaks obtained in X-ray stress analysis studies are often asymmetric. The use of K/sub ..beta../ rather than K/sub ..cap alpha../ radiation simplifies the problem of peak location, as only one Bragg peak needs to be analysed. It is shown, however, that the common practice of fitting a parabola to the top 15% of the data in a Bragg peak in order to determine the peak position, when the fitted region is asymmetric, can lead to large errors in the calculated stress. Asymmetric pseudo-Lorentzian functions have been found to provide the most satisfactory fits.
1983-01-01
Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma
International Nuclear Information System (INIS)
The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)
2007-12-01
ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD
Energy Technology Data Exchange (ETDEWEB)
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
1983-01-01
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22
815nm radiation from germicidal lamps
International Nuclear Information System (INIS)
An investigation of the intensity of electromagnetic radiation at a wavelength of 185nm emitted by a General Electric mercury discharge, germicidal lamp is described. From the measurement of the transmission of light as a function of wavelength from 185nm to 360nm, it was concluded that this type of germicidal lamp does not produce any biological or chemical effects through the 185nm line; the intensity of the 185nm line transmitted by the lamp was less than 0.1% of that for the 254nm line. Consequently, there was no discernable ozone production. (U.K.).
3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
1983-12-01
Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)
2004-11-30
International Nuclear Information System (INIS)
Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)
2004-11-30
Survival of gas phase amino acids and nucleobases in space radiation conditions
We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a ...
2008-01-01
Radiation processed composite materials of wood and elastic polyester resins
International Nuclear Information System (INIS)
The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of wood composite ...
1982-09-19
International Nuclear Information System (INIS)
Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).
1989-12-04
Plane electrode device for multiwire detector for ionizing radiations
International Nuclear Information System (INIS)
A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.
1986-07-01
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions
Energy Technology Data Exchange (ETDEWEB)
Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).
1992-02-01
Energy Technology Data Exchange (ETDEWEB)
Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating ...
1995-12-01
Assessment and control of fetal exposure
Energy Technology Data Exchange (ETDEWEB)
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, ...
1991-10-01
A VUV prism spectrometer for RICH radiator refractometry
A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).
2000-01-01
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Radiation technology of wood-plastic composite materials
International Nuclear Information System (INIS)
... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.
1981-10-02
Radiation chloration sulfochloration and sulfooxidation of organic compounds
International Nuclear Information System (INIS)
... halogenation ionizing radiations kinetics radiations reaction kinetics
International Nuclear Information System (INIS)
Forty cases of Ewing's sarcoma of various sites had attended the Department of Radiotherapy at the Wanless Hospital and the Miraj Medical Centre, attached to the Government Medical College, Miraj, Maharashtra, from January, 1970 through December, 1979. There were 28 male patients and 12 female patients in the series with a male to female ratio of 2.3:1. The youngest patient in the series was a female of 6 years of age with the tumour in the scapula and the oldest patient was a 32-year-old male with a lesion in the metacarpal bone. Sixty per cent of the cases were seen in the second decade. The average age of the patients was 13.5 years. The bones of the lower extremities were most commonly involved with the highest number (35 per cent) of the cases occurring in the femur. Involvement of the bones of the right side of the body was almost equal to that of the left side. Swelling over the site of the lesion and pain over the ...
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules and the segmental ...
2006-04-01
Risk of radiation-related subsequent malignant tumors in survivors of Ewing's sarcoma
International Nuclear Information System (INIS)
Twenty-four long-term survivors of Ewing's sarcoma were identified as being at risk for a second primary tumor. Among this group of patients followed from 3 to 22 y, 4 new bone tumors were observed, whereas 1.2 x 10"-"3 were expected. All new tumors arose in heavily irradiated areas. The risk associated with radiation after 3 years was 7.2 cases/million person-years per rad. The cumulative cancer risk over 10 years for irradiated patients was 35% (SE, 15.1%). Intensive chemotherapy (cyclophosphamide and vincristine administered in five or more courses) seemed to exert an enhancing effect, increasing the rate of development of new tumors.
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...
2007-01-01
International Nuclear Information System (INIS)
The activity of tyrosine aminotransferase (TAT) in the liver of mice subjected simultaneously to ionizing radiation and to local inflammatory process showed in the first 24 hours of the experiment statistically significant changes resulting from summation of the harmful effects of both factors. In the second 24-hour period an evident tendency was observed for return of a normal circadian rhythm of the enzyme. This points to presence of an endogenous mechanism of suppression of the manifestations of significant desynchronization of the circadian rhythm. The paper contains also a trial of mathematical analysis of changes in TAT activity in the circadian rhythm, a description and analysis or the suppression process, qualitative and quantitative determination of the phenomenon of cumulation of the effects of powerful stress factors acting on the animal organism. The obtained results were compared with the results of investigations of TAT activity changes obtained in ...
1980-01-01
Coherent spontaneous radiation of Frenkel excitons
International Nuclear Information System (INIS)
We have constructed a mathematical model that describes the coherent spontaneous radiation of a macroscopically filled exciton mode. We have demonstrated qualitatively ways in which a coherent subsystem of excitons can be formed. When this occurs under the influence of an external coherent source, exciton free induction occurs, while in the case of a spontaneous transition of the excitons to a coherent state through freezing of the reservoir of intermolecular interactions superradiance occurs. We have concluded that superradiance in the system of Frenkel excitons is possible under the influence of the non-Dicke mechanisms of self-induction of correlations, when the dipole transition moments of the individual atoms are coupled into a single macroscopic effective spin through their electrostatic interaction, this being analogous to the ordering of magnetic dipole moments in a ferromagnet.
1988-01-01
International Nuclear Information System (INIS)
We consider perturbations of a particular type (homogeneous of Bianchi type IX) from a closed Friedmann-Robertson-Walker model. By considering a perfect fluid, we obtain closed-form solutions for the perturbations in three interesting cases: stiff matter, radiation, and dust. As a cosmological application, we obtain an upper limit on the relative shear, (sigma/theta)_0 < b/sub 0exp/, if the microwave background radiation was last scattered at a mean red-shift
Fine ceramics center; Fuain seramikkusu senta
Energy Technology Data Exchange (ETDEWEB)
Fine ceramics center (JFCC) succeeded in the higher precision of thermal diffusivity measurement by the laser flash. This results are part of 'the research on thermophysical property measurement technique and standard substance of the functional material' by the intelligent establishing of a base promotion system of Science and Technology Agency. Cooperative research. thermal diffusivity with Natl. Res. Lab. of Metrology is one of the representative thermophysical property. The speed in which a heat transmits of the material is shown, and it is indispensable to the design of the high-temperature member subject. JFCC heralds the world as a standard substance for the thermal diffusivity measurement; 'TD-AL' using the alumina material is developed and is supplied in the spring in last year. Laser flash which uses laser beam for the heat source is general for the ...
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
The Atmospheric Radiation Monitor (ARM) uninhabited aerospace vehicle (UAV) program aims to develop measurement techniques and instruments suitable for a new class of high altitude, long endurance UAVs while supporting the climate community with valuable data sets. Using the Scaled Composites Proteus aircraft, ARM UAV participated in Mixed-Phase Arctic Cloud Experiment (M-PACE), obtaining unique data to help understand the interaction of clouds with solar and infrared radiation. Many measurements obtained using the Proteus were coincident with in-situ observations made by the UND Citation. Data from M-PACE are needed to understand interactions between clouds, the atmosphere and ocean in the Arctic, critical interactions given large-scale models suggest enhanced warming compared to lower latitudes is occurring.
2005-03-18
Mercury-free fluorescent lighting
Energy Technology Data Exchange (ETDEWEB)
A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid ...
1996-05-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the ...
1991-06-01
Prevalence of hepatosplenomegaly in beta thalassemia minor subjects in Iran
Energy Technology Data Exchange (ETDEWEB)
Introduction: Thalassemia is the most common hereditary blood disorder in the world. Iran is located on the thalassemic belt and there is a high prevalence of the hepatosplenomegaly in beta thalassemia minor patients which is reported to be very variable. The goal of this research was to study the frequency of these signs in the cases with beta thalassemia minor patients in Iran. Materials and methods: Two hundred and fifty-nine cases that referred to center for pre-marriage tests were divided into two groups according to their MCV, MCH, and HbA2 (beta thalassemia minor cases and control groups). Liver and spleen sizes were determined by ultrasonographic method and the two groups were compared with each other. Results: Average spleen volumes in case and control groups were 163.48 {+-} 133.97 and 126.29 {+-} 53.98 mm{sup 3}, respectively. Average spleen lengths in case and control ...
2009-01-15
Drop Test of the Candu Spent Fuel Storage Basket in MACSTOR/KN-400
International Nuclear Information System (INIS)
The MACSTOR/KN-400 of Wolsung power plant in Korea is a dry interim storage facilities. There are 400 long slender cylinders in MACSTOR/KN-400. In one cylinder, ten baskets where Candu spent fuels are loaded are stacked and stored. For this MACSTOR/KN-400 facilities, analyses and tests for the hypothetical accident conditions that might happen during moving and storing baskets into a cylinder were performed. The hypothetical accident conditions to be considered are two cases. One is the case of basket dropping onto the bottom plate of a cylinder. The other is the case of basket dropping onto the other basket top plate stored in the cylinder. For the drop analyses, the case of hanging cylinder and the case of cylinder on the unyielding target surface were considered. Based on the dropping analysis, testing condition was determined as the latter case that is for ...
2009-06-01
International Nuclear Information System (INIS)
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work ...
2006-01-01
Radiant emittance of xenon positive column discharges
Energy Technology Data Exchange (ETDEWEB)
An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gas discharges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the resonance level is calculated using radiation trapping theory. The ...
1994-12-31
Rayleigh Scattering in Rare Gas Liquids
The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.
2002-01-01
Decommissioning of facility for use of radioisotopes on waste management and disposal facility
Energy Technology Data Exchange (ETDEWEB)
All the tests have been finished up in the Waste Management and Disposal Facility which has been used for the safety tests of solidified radioactive waste on sea dumping disposal. The decommissioning of this facility was performed for use of radioisotopes. This report describes the plan on decommissioning of facility for use of radioisotopes, the contamination checking methods and measurement of radioactivity, the fore case and practice for amount of generated radioactive wastes, the operation procedures for dismantlement, the safety measures, the expenses for decommissioning and so on. (author)
1999-09-01
Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium
International Nuclear Information System (INIS)
Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to ...
2003-11-01
International Nuclear Information System (INIS)
This case study is an application, to a nuclear power plant, of the methodology for quantifying environmental costs and benefits, contained in the regional energy plan, adopted in April, 1983, by the Northwest Power Planning Council, pursuant to Public Law 96-501.The study is based on plant number 2 of the Washington Public Power Supply System (WNP-2), currently nearing completion on the Hanford Nuclear Reservation in eastern Washington State. This report describes and documents efforts to quantify and estimate monetary values for the following seven areas of environmental effects: radiation/health effects, socioeconomic/infrastructure effects, consumptive use of water, psychological/health effects (fear/stress), waste management, nuclear power plant accidents, and decommissioning costs. 103 references.
British Library Electronic Table of Contents (United Kingdom)
The determination of residual stress (RS) in case-hardened steel gear truck synchronisers coated with thermal sprayed molybdenum was carried out using neutron and synchrotron X-ray diffraction. Two samples with different coating thicknesses (about 120 ?m and 1.4 mm) and different steel substrates (16MnCr5 and SAE4140, respectively) were investigated. Microanalysis revealed substantial porosity in both samples and some debonding was observed between the thin coating and the substrate. The bulk hardness of the SAE 4140 proved to be much higher than the 16MnCr5 and the surface case-hardening increased it by a further 20%. The full three-dimensional stress depth-profile was determined by neutron diffraction (ND) in both the coatings and the substrates, while synchrotron radiation allowed a dep...
2006-01-01
A phenomenological model for the macroscopic characteristics of irradiated silicon
International Nuclear Information System (INIS)
The dependence of the carrier concentrations, of the resistivity and of the Hall coefficient of irradiated silicon on the neutron fluences has been investigated, starting from the supposition that the main phenomena induced by irradiation in the semiconductor bulk are shallow-donor removal and deep-centres creation. The free parameters of the model are initial doping of the starting material, the permitted energy level values of the radiation-induced centres in the semiconductor band gap and their introduction rates. The influence of each parameter on the calculated dependences is studied in detail, for three cases: one deep acceptor-like centre, two deep acceptors and one deep acceptor plus one deep donor-like centre. each of the three cases is discussed in correspondence with different experimental results.
British Library Electronic Table of Contents (United Kingdom)
Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...
2010-01-01
Superconducting strip detectors as position sensitive particle detectors
Energy Technology Data Exchange (ETDEWEB)
The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)
1994-02-01
Somatic radiation risk in different mammography techniques
International Nuclear Information System (INIS)
By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is ...
1981-01-01
International Nuclear Information System (INIS)
By the department Radio-ecology of the Laboratory for Radiation Research, in the period 1981 up to 1989 inclusive, the transfer has been studied, from soil to plant, of a number of important activation and fission products, originating in the nuclear-power production in nuclear power plants. The purpose of this study was twofold: on the one side the quantification of this transfer for various agrarian systems and on the other side to find out in how far, after an accidental contamination, certain agriculture activities can influence essentially the transfer and subsequently the radiation burden for the population. Emphasis lay, the last years, in particular upon this second aspect. The results of this study form essential basic data for diffusion models for radioactive materials which, in turn, are important in estimating the effects of measures. (author). 6 refs.; 4 figs.
Energy Technology Data Exchange (ETDEWEB)
Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of British children to ...
2009-12-01
Aerosol-induced changes of convective cloud anvils produce strong climate warming
The effect of aerosol on clouds poses one of the largest uncertainties in estimating the anthropogenic contribution to climate change. Small human-induced perturbations to cloud characteristics via aerosol pathways can create a change in the top-of-atmosphere radiative forcing of hundreds of Wm-2. Here we focus on links between aerosol and deep convective clouds of the Atlantic and Pacific Intertropical Convergence Zones, noting that the aerosol environment in each region is entirely different. The tops of these vertically developed clouds consisting of mostly ice can reach high levels of the atmosphere, overshooting the lower stratosphere and reaching altitudes greater than 16 km. We show a link between aerosol, clouds and the free atmosphere wind profile that can change the magnitude and sign of the overall climate radiative forcing. We find that increased aerosol loading is associated with taller cloud towers and anvils. The taller clouds ...
2010-05-01
Estimation of cancer risks from radiotherapy of benign diseases
Energy Technology Data Exchange (ETDEWEB)
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...
2006-08-15
Estimation of cancer risks from radiotherapy of benign diseases
International Nuclear Information System (INIS)
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true risks by one order of magnitude, yet in ...
2006-08-01
Critical assessment of the Schroedinger picture of quantum mechanics
Energy Technology Data Exchange (ETDEWEB)
We provide an example in which the Heisenberg and the Schroedinger pictures of quantum mechanics give different results, thus confirming the statement of P.A.M. Dirac that the two pictures may lead to inequivalent results. We consider a one-dimensional nonrelativistic charged harmonic oscillator (frequency {omega}{sub 0} and mass m), and take into account the action of the radiation reaction and the vacuum electromagnetic forces on the charged oscillator. We show that the Heisenberg picture gives the correct value, {Dirac_h}{omega}{sub 0}/2, for the ground state energy of the harmonic oscillator in both cases of classical and quantized vacuum fields. In the case of the Schroedinger picture, considering classical vacuum fields, and using a simple calculation for the classical radiation reaction force that is valid in the limit of large mass (mc{sup 2} >> {Dirac_h}{omega}{sub 0}), we obtain ...
2002-12-16
Neutron leakage benchmarks for water moderators
Energy Technology Data Exchange (ETDEWEB)
Fission reaction rates for four nuclides were measured in the leakage spectrum outside spherical water moderators of various radii surrounding a {sup 252}Cf neutron source. Using the MCNP transport code, matching calculations were made with highly detailed modeling of the measurement apparatus. The calculations predicted significantly higher leakage of neutrons in the epicadmium energy range than was found in the measurements. A discrepancy of the same sign but weaker magnitude was found for thermal neutrons. These discrepancies may be relevant to problems with criticality calculations in special cases.
1994-12-31
Nuclear reactor with external structure cooling by natural convection
International Nuclear Information System (INIS)
The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.
Interpolation theory and influence of boundary conditions on room air diffusion
Energy Technology Data Exchange (ETDEWEB)
This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).
1991-01-01
Gastrointestinal radiography using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).
1985-01-01
Ewing's sarcoma of the humerus mimicking fibrous dysplasia on imaging and biological behavior
International Nuclear Information System (INIS)
We present the case of a 12-year-old girl who presented with a pathological fracture through a benign-appearing osteolytic lesion that was presumed to represent fibrous dysplasia. The fracture healed, and over the next 2.5 years there was further refracturing and healing with progressive osteolysis. A biopsy was performed and revealed Ewing's sarcoma. The disease was locally controlled by neoadjuvant chemotherapy and radiation therapy. The patient is disease free with excellent function 6 years following the discovery of the lesion. We illustrate and discuss the sequence of events. (orig.)
2005-05-01
Employment of /sup 203/Pb isotoic solution without a carrier for erythrocyte tracing
Energy Technology Data Exchange (ETDEWEB)
Possibilities of applying the Pb/sup 203/ isotonic solution without a carrier as a label of blood erythrocytes, are found. There is a number of advantages in the Pb/sup 203/ isotonic solution without a carrier, such as a high label efficiency (above 95%), a short half-life (52 hours), and a low radiation dose. These factors prove to be favourable as compared with Cr/sup 51/ widely used for these purposes. Besides, of all preparations used up to now to treat erythrocytes and to scan the spleen, it is only in the case of Pb/sup 203/ isotonic solution without a carrier that no weight amounts of chemical substances do not enter the organism.
1981-08-01
Energy Technology Data Exchange (ETDEWEB)
In an ideal system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun rays fall on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions are not realizable in practice; in this case, the parabolic dish system is called real system. In this paper a procedure for analysing the flux distribution on the receiver internal surfaces is presented for a cavity receiver with a real parabolic dish collector. First, the theoretical principles are discussed. Then the effect of the inaccuracy in the collector and in the sun tracking on the insolation pattern is described using an example.
1987-06-01
Different techniques for measuring radon concentration in a spa environment
International Nuclear Information System (INIS)
In the context of radiation protection for both workers and the population in general, natural sources of radiation, and in particular radon gas and its short-life decay products assume great importance. In particular, workers in thermal spas can easily be exposed to a level of radon radiation and its decay products comparable to those in uranium mines, though often these workers are unaware of the danger. The main source of radon in thermal baths is the thermal water itself, coming as it often does from deep springs, and this can produce high radon concentrations which are left in those areas in which therapy is carried out. Another factor which cannot be overlooked is the radioactive content of thermal mud, often matured for long periods by contact with thermal water. Thermal cures, though varying slightly from site to site, consist principally of mud cures, hydro-therapy and inhalation in various forms. Both health ...
2002-10-08
British Library Electronic Table of Contents (United Kingdom)
Szmidt and Kacprzyk (Lecture Notes in Artificial Intelligence 3070:388?393, 2004a) introduced a similarity measure, which takes into account not only a pure distance between intuitionistic fuzzy sets but also examines if the compared values are more similar or more dissimilar to each other. By analyzing this similarity measure, we find it somewhat inconvenient in some cases, and thus we develop a new similarity measure between intuitionistic fuzzy sets. Then we apply the developed similarity measure for consensus analysis in group decision making based on intuitionistic fuzzy preference relations, and finally further extend it to the interval-valued intuitionistic fuzzy set theory.
2009-01-01
International Nuclear Information System (INIS)
The outcome was retrospectively examined and prognostic factors were discussed for arterial chemo-infusion therapy (ACT) through an implanted reservoir system and radiation therapy (RT) in patients with unresectable intrahepatic cholangiocarcinoma (CCC). ACT plus RT were conducted to 25 patients (mean age 61.7 y, M/F 12/13, stage III-IVB) during 10 years from 1996 to 2005 with various regimens of cisplatin (CDDP), 5- fluorouracil (FU), epirubicin (FARM), mitomycin C (MMC) plus 39-50 Gy of radiation in a fractionated manner partly involving internal RT (2 cases, 15 Gy) and RT for metastatic bone (1, 25 Gy). The survival rates at 1, 2 and 3 years after ACT+RT were respectively 52.5, 43.7 and 28.1%; total efficacy (PR) was 36% (9/25) at 6 months; and significantly good prognostic factors were found to be female and absence of metastasis remote and/or lymphatic around artery. Authors concluded that ACT+RT was a meaningful ...
2007-11-01
Energy Technology Data Exchange (ETDEWEB)
The present study discusses the contribution of the adoption of more rigorous and objective criteria to the selection and analysis of information sources, leading to more scientific rigour when registering phytotherapic drugs. To this end, it is herein proposed the adoption of a previously tested and acknowledged methodology, namely the Systematic Revision, as a standard for phytotherapic drug analyses. In order to show differences brought about by the Systematic Revision during the registration procedures of phytotherapic drugs, the case of the Maytenus ilicifolia (known popularly in Brazil as 'espinheira-santa') is presented. As it is well known, the use of ionizing radiation is expanding, especially in medicine and pharmacy. Therefore, gamma radiation was applied to the microbiological quality control of phytotherapic matrices. Results indicated a positive contribution of Systematic Revision to the ...
2006-07-01
Spontaneous Radiation Emission from Short, High Field Strength Insertion Devices
Energy Technology Data Exchange (ETDEWEB)
Since the earliest papers on undulaters were published, it has been known how to calculate the spontaneous emission spectrum from ''short'' undulaters when the magnetic field strength parameter is small compared to unity, or in ''single'' frequency sinusoidal undulaters where the magnetic field strength parameter is comparable to or larger than unity, but where the magnetic field amplitude is constant throughout the undulater. Fewer general results have been obtained in the case where the insertion device is both short, i.e., the magnetic field strength parameter changes appreciably throughout the insertion device, and the magnetic field strength is high enough that ponderomotive effects, radiation retardation, and harmonic generation are important physical phenomena. In this paper a general method is presented for calculating the radiation spectrum for ...
2005-09-15
Prenatal exposure to ionizing radiation and subsequent development of seizures
International Nuclear Information System (INIS)
Seizures are a frequent sequela of impaired brain development and can be expected to affect more children with radiation-related brain damage than children without such damage. This report deals with the incidence and type of seizures among survivors prenatally exposed to the atomic bombing of Hiroshima and Nagasaki, and their association with specific stages of prenatal development at the time of irradiation. Fetal radiation dose was assumed to be equal to the dose to the maternal uterus. Seizures here include all references in the clinical record to seizure, epilepsy, or convulsion. Histories of seizures were obtained at biennial routine clinical examinations starting at about the age of 2 years. These clinical records were used to classify seizures as febrile or unprovoked (without precipitating cause). No seizures were ascertained among subjects exposed 0-7 weeks after fertilization at doses higher than 0.10 Gy. The incidence of seizures ...
Energy Technology Data Exchange (ETDEWEB)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography showed complete ...
1994-10-01
International Nuclear Information System (INIS)
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography showed complete ...
1994-01-01
Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus
International Nuclear Information System (INIS)
Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.
1987-08-01
Fully quantized many-particle theory of a free-electron laser
Energy Technology Data Exchange (ETDEWEB)
A fully quantized many-particle theory of the standard free-electron laser in the small-signal, cold-beam regime is presented. The approach is based on an evaluation of the time-evolution operator in the interaction picture to first order in the quantum-mechanical recoil. For algebraic convenience we use the moving (Bambini-Renieri) frame, in which resonance occurs for zero electron momentum. Though we neglect space-charge effects, genuine many-particle contributions still show up, because the radiation emitted by one electron can be amplified by another electron. Our main results are gross features of the amplification, such as gain and spread, are virtually without many-particle effects. These effects are mainly important in the case of spontaneous emission. For a sufficiently high current, the buildup of the laser field from vacuum is enhanced by amplified spontaneous emission. Incoherence of the spontaneous radiation ...
1983-02-01
International Nuclear Information System (INIS)
The radiographic appearance of Ewing's sarcoma was studied retrospectively in 22 patients who survived 5 years or longer after diagnosis and treatment. Expected changes from treatment, including regression of the extraosseous soft tissue mass, periostitis, and reconstitution of the cortex, occurred in all patients. Local recurrence occurred in one patient 10 years after complete remission whereas secondary osteosarcoma occurred more than 5 years after complete remission in two other cases. Both recurrent and secondary tumors presented as new lytic foci at the site of the original primary lesion. Lytic changes from radiation (radiation osteitis) may develop more than 2 years after treatment and in this sample; such findings were widely distributed in the radiation port. The authors conclude that bone remodeling and postradiation changes occur slowly over 2 years after treatment, and that any localized ...
Application of a finite element method to leak before break (LBB) of a heat exchanger
International Nuclear Information System (INIS)
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural ...
2003-08-17
Key impact parameters for application of alternative source term to Kori unit 1
International Nuclear Information System (INIS)
The object of this paper is to identify the key elements that impact a radiation dose at EAB (Exclusion Area Boundary). This study is based on the AST (Alternative Source Terms) as defined in Regulatory Guide 1.183. The LOCA (Loss of Coolant Accident) and the LRA (Locked Rotor Accident) are selected as limiting cases. A sensitivity analysis of accidental behavior with respect to various parameters during LOCA and LRA at Kori Unit 1 is also undertaken for the following objectives: to determine the limiting parameters, to find the impact trend of the radiation dose, and to find the safety margin between AST and TID (Technical Information Document) methodologies. This work confirms that key parameters are particulate removal rate, decontamination factor, iodine chemical form, gap fraction, partitioning factor, and the impact of isotopes group. Comparing TID with AST, the radiation dose of TID is about 80% ...
2010-08-01
Energy Technology Data Exchange (ETDEWEB)
Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the relevant levels can be ...
2009-10-15
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...
[Study of body composition by potassium-40 measurement in patients with breast and uterine cancer].
Total potassium was assayed in 150 normal weight and obese females (cervical carcinoma-52, endometrial carcinoma-25 and breast cancer-73) by measurements of 40K spontaneous radiation in a low-background chamber. Control group included 30 healthy and 25 obese females. Computations of body cell and extracellular mass and fat were carried out on the basis of the said measurements. Extracellular fluid volume was measured in 38 patients by X-ray fluorescence method using sodium bromide. The results pointed to a body cell mass deficit matched by increased extracellular mass due to a higher fat level in patients with breast, endometrial and cervical carcinoma. The said correlation was particularly pronounced in obese patients. The beneficial effect of treatment was more often observed in patients with normal body weight. PMID:3739295
1986-01-01
Measurement of radon daughter product burden by TLD dosemeters
International Nuclear Information System (INIS)
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
Energy Technology Data Exchange (ETDEWEB)
An experiment lasting a number of hours was carried out with 6 men under standardised climate chamber conditions to find out to what extent wallpaper that reflects about 65-75% in the infra-red range by comparison with normal wallpaper that reflect only 3-5% of heat, has measurable positive effects on the thermoregulation of the human body and the human sensation of temperature. The measurements of skin temperature and heat flow intensity in the deeper areas of the body and the periphery, and metabolic heat conversion measurements (indirect calorimetry) confirm that infra-red reflection of the heat irradiated from the body lead to a measurable heat recovery on the body surface with a reduction of metabolic conversion. It was proved that it is possible to reduce the average room temperature by up to 4 K whilst maintaining the same degree of thermal comfort, which corresponds to a 20% saving in heating ...
1985-06-01
Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces
Energy Technology Data Exchange (ETDEWEB)
A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal ...
1981-10-01
Energy Technology Data Exchange (ETDEWEB)
Because of the importance of water vapor, the ARM program initiated a series of three intensive operating periods (IOPs) at its CART (Cloud And Radiation Testbed) site. The goal of these IOPs is to improve and validate the state-of-the-art capabilities in measuring water vapor. To date, two of the planned three IOPs have occurred: the first was in September of 1996, with an emphasis on the lowest kilometer, while the second was conducted from September--October 1997 with a focus on both the upper troposphere and lowest kilometer. These IOPs provided an excellent opportunity to compare measurements from other systems with those made by the CART Raman lidar. This paper addresses primarily the daytime water vapor measurements made by the lidar system during the second of these IOPs.
1998-04-01
Energy Technology Data Exchange (ETDEWEB)
Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.
1998-01-01
A high sensitivity two-color interferometer for pulsed power plasmas
International Nuclear Information System (INIS)
A high sensitivity, high bandwidth, two-color interferometer (1064 and 532 nm) has been tested on the Hawk pulsed power generator at the Naval Research Laboratory. The phase resolution is 10"-"5 waves with a rise time of 3 ns, a new capability for diagnosing plasmas, and neutrals in pulsed power experiments. The two-color feature is used to distinguish phase shifts from free (plasma) electrons and bound (neutral and ion) electrons. Simultaneous electron and neutral density measurements were demonstrated in a plasma opening switch (POS) experiment. The ability to measure small phase shifts with fast rise time were demonstrated in a plasma filled diode experiment. The high sensitivity and vibration isolation enable neutral gas distribution measurements from supersonic nozzles used in plasma radiation source experiments. Examples of these measurements and future applications are ...
Energy Technology Data Exchange (ETDEWEB)
The absorption of solar heat and the attendant thermal and mechanical loadings on the tubes of cavity receivers depend predominantly on the flux distribution of the incident solar radiation. For an axially symmetric cavity receiver with a parabolic dish collector, it is simple to determine the insolation pattern on the receiver internal surfaces if the system is ideal. In such a system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun's central ray impinges on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions cannot be achieved in practice, and therefore the feasible parabolic dish system is referred to as a real system although, in actual fact, it is only an approximation to any actual system. The purpose of this paper is to devise calculation principles which permit analysis of a receiver designed for ideal conditions to verify its structural adequacy under the ...
1990-11-01
International Nuclear Information System (INIS)
Generally, neutron, ion and electron Irradiations cause a substantial amount of hardening and significantly alter the deformation behavior of metals and alloys at relatively low irradiation temperatures. A radiation hardening is caused by the formation of microstructural defects such as dislocation loops, voids and precipitates under irradiation. Therefore, it is important to have a better knowledge of the irradiation induced microstructural defects under irradiation condition. As a part of the National mid- and long-term atomic energy R and D program, we are dealing with the radiation hardening behavior in Fe-Cr binary alloy. Fe-Cr binary alloy is a base alloy of Ferritic/Martensitic steel(F/M steel) planning to use for the Gen IV nuclear system. In this work, we investigated the radiation hardening and microstructural defect evolution in ion irradiated Fe-Cr alloys with irradiation temperature using nano-indentation ...
2009-05-01
Energy Technology Data Exchange (ETDEWEB)
Experimental and numerical investigations were performed for the laminar burning velocity and the flame structure of laminar premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames. Measurements of the laminar burning velocity were conducted by using a flame cone angle method for a circular nozzle burner. Numerical simulation was performed using one-dimensional plane flame code including radiation heat loss with an optically thin model. It was shown that the laminar burning velocity decrease with CO{sub 2} addition even though the adiabatic flame temperature is the same as that for CH{sub 4}/Air flames. The radiation heat loss is significant for the CH{sub 4}/O{sub 2}/CO{sub 2}, flames, and the flame temperature and laminar burning velocity decreases when the radiation heat loss is considered. Effects of thermal properties, radiation, and chemical reaction on the determination of the laminar ...
1999-07-25
Microwave radiation effects on the thermally driven oxidase of erythrocytes
Energy Technology Data Exchange (ETDEWEB)
Sheep red blood cells (SRBCs) were labelled with a concanavalin A-luminol-bovine serum albumin conjugate specific for the transmembrane anion transport protein (Band 3) and exposed to 2450-MHz continuous-wave microwave radiation at an average specific absorption rate of 91W/kg for 10 min. The temperature was held constant at 25, 37, 40, 42, or 45C with an airflow heat-exchange system. Following exposure to microwave or air heating, the decrease in residual base-activated chemiluminescence (CL) of the SRBCs was measured as an indication of infield oxidase activity. Air heating resulted in a significant decrease in residual CL at temperatures above 37C (74% decrease at 45C). Microwave radiation inhibited the decline in residual CL above 37C. At 45C the inhibition was 40%. The results suggest microwave radiation either reversibly altered the thermodynamics of oxygen binding to haemoglobin or failed to ...
1986-01-01
International Nuclear Information System (INIS)
Radiation-and-thermal-combined degradation of some kinds of cable insulating and jacketing materials was evaluated by accelerated aging tests. Plasticized polyvinyl chloride (PVC), silicone rubber, crosslinked and non-crosslinked halogen-free flame-retardant polyolefins (NH-XLPO and NH-PO) and ethylene-propylene rubber (EP rubber) of experimental formulation were degraded at accelerated rates, that are 50-1000 times the degradation rate under standard conditions (e.g.; 1Gy/h, 50degC), and a method to assess the lifetime of these materials under standard conditions was studied. The degradation was investigated by measuring tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for these materials were in proportion to the increase in accelerated rate. The PVC lifetime estimated from sequential aging tests had a tendency to extend beyond that from simultaneous aging tests, while the lifetime of other ...
1994-01-01
Gene expression analysis after low dose ionising radiation exposure of the developing organism
International Nuclear Information System (INIS)
Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two main stages of ...
2007-09-01
Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data
The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on several hours (2-10) an appropriate maximum of ...
2010-01-01
Measuring instrument for radiometric monitoring of solids and heavy metals in water
International Nuclear Information System (INIS)
A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the ...
1979-01-01
Electric field measurement on time domain generated by corona on insulators on distribution systems
Energy Technology Data Exchange (ETDEWEB)
Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The aim of this work was to study acute alterations of the enterohepatic recirculation (EHR) of bile acids 3 days after an 8-Gy radiation exposure in vivo in the rat by a washout technique. Using this technique in association with HPLC analysis, the EHR of the major individual bile acids was determined in control and irradiated animals. Ex vivo ileal taurocholate absorption was also studied in Ussing chambers. Major hepatic enzyme activities involved in bile acid synthesis were also measured. Measurements of bile acid intestinal content and intestinal absorption efficiency calculation from washout showed reduced intestinal absorption with significant differences from one bile acid to another: absorption of taurocholate and tauromuricholate was decreased, whereas absorption of the more hydrophobic taurochenodeoxycholate was increased, suggesting that intestinal passive diffusion was enhanced, whereas ileal active transport ...
2004-02-01
Revisiting light neutralino scenarios in the MSSM
We revisit the case of a light neutralino LSP in the framework of the MSSM. We consider a model with eleven free parameters. We show that all scenarios where the annihilation of light neutralinos rely mainly on the exchange of a light pseudoscalar are excluded by direct detection searches and by Fermi measurements of the gamma-flux from dwarf spheroidal galaxies. On the other hand, we find scenarios with light sleptons that satisfy all collider and astroparticle physics constraints. In this case, the lower limit on the LSP mass is 12.6 GeV. We discuss how the parameter space of the model will be further probed by new physics searches at the LHC.
2011-01-01
A theoretical study of radon measurement with activated charcoal
Energy Technology Data Exchange (ETDEWEB)
Diffusion of radon in a bed of activated charcoal is described by diffusion equations. An analytical solution of these equations is presented for the case of constant radon concentration in the atmosphere. The solutions are given separately for short term and long term exposure. An analytical form of the calibration constant f for long term exposure and constant radon concentration in air, was found. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. (orig.) 10 refs.
1998-04-11
International Nuclear Information System (INIS)
Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.
1980-03-12
Energy Technology Data Exchange (ETDEWEB)
A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.
1981-01-01
Initial electron-beam characterizations for the Los Alamos APEX Facility
Energy Technology Data Exchange (ETDEWEB)
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.
1991-01-01
Initial electron-beam characterizations for the Los Alamos APEX Facility
Energy Technology Data Exchange (ETDEWEB)
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.
1991-12-31
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
Energy Technology Data Exchange (ETDEWEB)
Discusses methods for determining ash content in coal using backscattering in X-ray fluorescence. The following aspects are evaluated: principle of ash content determination, energy sources, factors that influence measurement accuracy, reliability. Types of X-ray fluorescence analyzers developed in Czechoslovakia and manufactured in the Czech Republic are comparatively evaluated. Operation of the RPM 113.1 radionuclide X-ray fluorescence analyzer developed by the PAR company and used for measuring ash content in coal and coal calorific value is discussed. 7 refs.
1993-09-01
Energy Technology Data Exchange (ETDEWEB)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
1993-12-01
Primary Ewing's sarcoma of the vertebral column
International Nuclear Information System (INIS)
To determine the demographics, imaging findings, clinical symptoms, and prognosis of primary vertebral Ewing's sarcoma (PVES). A retrospective review of medical records and radiological studies of patients diagnosed with PVES from 1936 through 2001 in our institution and Department of Pathology consultation files was undertaken. Metastatic and soft tissue Ewing's sarcoma cases were excluded. From a total of 1,277 cases of Ewing's sarcoma, 125 (9.8%) had a primary vertebral origin. There were 48 females and 76 males. Patient ages ranged from 4 to 54 (mean 19.3, standard deviation 10.7, median 16) years. Vertebral column distribution was four cervical (3.2%), 13 thoracic (10.5%), 31 lumbar (25%), and 67 sacrum (53.2%). More than one vertebral segment was involved in ten cases (8%). Satisfactory imaging studies were available in 51 patients: 49 radiographs, 27 computerized tomography (CT), and 23 magnetic resonance imaging ...
2004-09-01
[Comparison of wound morphology following gunshots by machine guns and sub-machine guns].
Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The ...
Clinical evaluation of serum ferritin to iron ratio in malignant diseases
Energy Technology Data Exchange (ETDEWEB)
Serum ferritin levels were measured in 72 normal subjects and in 214 cases with various diseases by an immunoradiometric assay. In normal subjects, the serum ferritin levels were 27-230 ng/ml. Elevated serum ferritins were observed in most cases with iron excess and acute hepatitis. Markedly elevated levels were found in the majority of cases with acute leukemia, malignant lymphoma, hepatoma, and pancreatic cancer. High ferritin levels were also found in other malignant diseases. However, the range overlapped broadly with that of nonmalignant diseases. The serum ferritin correlated significantly with serum iron in normals and in those with iron deficiency anemia. In most nonmalignant cases, the serum ferritin and iron levels distributed on a regression line obtained from levels in normals and those with iron deficiency anemia. However, 92% of the malignant cases ...
1981-07-01
Energy Technology Data Exchange (ETDEWEB)
The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.
2009-03-15
Tests for mutagencity of free radicals formed in irradiated sugars and amino acids
International Nuclear Information System (INIS)
Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.
1977-05-01
International Nuclear Information System (INIS)
The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.
1987-09-14
Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters
International Nuclear Information System (INIS)
The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.
1992-01-01
Quantum Cloning for Absolute Radiometry
International Nuclear Information System (INIS)
In the quantum regime information can be copied with only a finite fidelity. This fidelity gradually increases to 1 as the system becomes classical. In this Letter we show how this fact can be used to directly measure the amount of radiated power. We demonstrate how these principles can be used to build a practical primary standard.
2010-08-20
Energy Technology Data Exchange (ETDEWEB)
Pyrheliometric methods are described (particularly methods for measuring the solar constant), and theoretical and experimental studies in this field are surveyed and systematized. Particular attention is given to the analysis of instruments intended for pyrheliometers used as standards, reference instruments, and solar-constant meters is examined, and consideration is given to methods for determining the thermal-radiation properties of absorbing coatings and methods for calculating the absorption coefficients of cavity receivers.
1981-01-01
Occupational exposure information system in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)
2005-07-01
Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project
Energy Technology Data Exchange (ETDEWEB)
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
1999-03-01
Extraction of Kaon Formfactors from K->mu nu gamma Decay at ISTRA+ Setup
The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy
Energy Technology Data Exchange (ETDEWEB)
An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).
1991-12-01
Quantifying costs of forecast errors: A case study of the warehouse environment
British Library Electronic Table of Contents (United Kingdom)
Our study evaluates the impact of forecast errors on organizational cost by simulating a labor-intensive warehouse environment using realistic cost data from a case study. Unlike past studies that measure forecast error in terms of forecast standard deviation, our study also considers the impact of forecast bias, and the complex interaction between these variables. Two cases of organizational cost curves are considered, with differing and asymmetric structures. Results find forecast bias to have a considerably greater impact on organizational cost than forecast standard deviation. Particularly damaging is a high bias in the presence of high forecast standard deviation. Although biasing the forecast in the least costly direction is shown to yield lower costs, sensitivity analysis shows that...
2009-01-01
The tunneling universe in scalar-tensor theory with matter
Energy Technology Data Exchange (ETDEWEB)
In this paper, the wavefunction of the universe with a tunneling boundary condition is considered in the context of the Brans-Dicke-type scalar-tensor theory with matter. The matter may be interpreted as a D-particle (or D0-brane) in string theory when the Brans-Dicke parameter {omega} is -1. We study two simple examples. The first example, the {gamma}=0 (matter) case, has a scale factor duality even if the low energy string action is coupled to matter. The universe undergoes quantum transition from super-inflationary (pre-big-bang) to deflationary (post-big-bang) phase. We calculate the transition rate by solving the Wheeler-DeWitt equation and find that it is non-vanishing. The two phases are disconnected classically. The second example is the {gamma}=1/3(radiation) case. With the help of earlier work this matter can be identified with a D0-brane in string theory. In this case, due to the absence of ...
2007-10-21
Energy Technology Data Exchange (ETDEWEB)
Macrocephaly was defined as a head measuring larger than 98th percentile. We have evaluated CT findings and head growth curves in 25 infants with large heads. Ten (40%) of 25 infants with large heads were normal developmentally and neurologically. Five (20%) of those were mentally retarded. The other 10 infants (40%) included hydrocephalus (4 cases), malformation syndrome (3 cases), brain tumor (1 case), metabolic disorder (1 case) and degenerative disorder (1 case). Their head growth curves were typed as (I), (II) and (III): Type (I) (excessive head growth curve to 2 SDs above normal); Type (II) (head growth curve gradually approached to 2 SDs above normal); Type (III) (head growth curve parallel to 2 SDs above normal). Ten of macrocephaly with normal psychomotor development were studied clinically and radiologically in details. They were all male. CT pictures ...
1982-01-01
Solar energy conversions: solar-electric thermophotovoltaic systems and solar-powered gas lasers
Energy Technology Data Exchange (ETDEWEB)
This paper deals with conversions of solar energy efficiently into electricity and into gas laser radiation. In the first section, a review study of the possibility of a solar-electric thermophotovoltaic (TPV) device has been done. In a proposed extension of the TPV concept, a Cassagranian optical system concentrates solar radiation to heat a blackbody cavity to 2400/sup 0/K. A double-layer solar cell, GaAs and Si, forming the cylindrical surface concentric to the blackbody cavity, receives the blackbody radiation and converts it into electricity efficiently. A cell conversion efficiency of 50% or more would be possible with the TPV system. The second section explores the concept of blackbody radiation pumping of gas laser media as a step toward utilization of solar energy as a laser pumping source. To demonstrate this concept, an experiment was performed in which various gas mixtures of CO/sub 2/ and ...
1980-12-01
Revisited the mathematical derivation wall thickness measurement of pipe for radiography
Energy Technology Data Exchange (ETDEWEB)
Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the ...
2007-07-01
First trimester measurements of nasal bone length using three-dimensional ultrasound
British Library Electronic Table of Contents (United Kingdom)
Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...
2009-01-01
Design of automatic monitoring network for the water quality management of river basin
Energy Technology Data Exchange (ETDEWEB)
In designing automatic water quality monitoring networks for a river basin, determination of measurement locations and items is critical to the effectiveness of the total system. In this paper we studied how to decide these two design factors when a monitoring network is designed for the purpose of water quality surveillance and emergency alarm. For measurement locations, candidate sites are chosen based on the intake amount for water supply and the point sources of contamination. Then, detailed locations are decided according to the contaminant flow distance. As for measurement items, characteristics and the accident history of water pollution in the basin must be taken into account. Considering economic aspects, we proposed a two-stage measurement plan: basic components for all locations and selective ones variable for different locations. Proposed methodology is demonstrated through a ...
1996-04-30
Assessment of MCNP-4B code using measurement data of Wolsung nuclear power plant 2
International Nuclear Information System (INIS)
The benchmark calculations have been performed for MCNP-4B code using the measurement data of Wolsong nuclear power plant 2. In this study, the benchmark calculations have been performed for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. Cross-section libraries were newly generated from ENDF/B-VI release 3 through NJOY97.114 data processing system and a three-dimensional full core model was developed for MCNP calculation. The simulation results have shown that the criticality is estimated within 4 mkn and the estimated reactivity worth of the control devices are generally consistent with the measurement data. In certain cases, the simulation results have shown large discrepancies against the measurement data, which will be sturdied further in the near future.
2001-05-01
1991 ice jamming along the Saint John River: a case study
Energy Technology Data Exchange (ETDEWEB)
Field investigations of major and damaging ice jamming on the Saint John River at Dickey, Maine , and at Sainte-Anne de-Madawaska, New Brunswick, in 1991, were described. The investigations included measurement of water surface profiles and shear wall heights at both sites. The measurements were supplemented by information from local observers and data collection agencies. Using a simplified equilibrium analysis, ice jam thickness and water level at the Dickey site was found to be generally in agreement with observed values. At Sainte-Anne-de-Madawaska sufficient data was obtained to construct and calibrate the numerical model RIVJAM which determined the configuration of the jam in nonequilibrium reaches. Use of the model enabled the successful reproduction of a measured water profile along the jam and the prediction of the approximate thickness of the jam, which was generally less than the measured ...
1996-04-01
Radiation inactivation target size of rat adipocyte glucose transporter
Energy Technology Data Exchange (ETDEWEB)
In situ assembly states of rat adipocyte glucose transport protein in plasma membrane (PM) and in microsomal pool (MM) were assessed by measuring target size (TS) of D glucose-sensitive, cytochalasin B binding activity. High energy radiation inactivated the binding in both PM and MM by reducing the total capacity of the binding (B/sub T/) without affecting the dissociation constant (K/sub D/). The reduction in B/sub T/ as a function of radiation dose was analyzed based on classical target theory, from which TS was calculated. TS in the PM of insulin-treated adipocytes was 58 KDa. TS in the MM of noninsulin-treated and insulin-treated adipocytes were 112 and 109 KDa, respectively. With MM, however, inactivation data showed anomalously low radiation sensitivities at low radiation doses showing a shoulder in the semilog plots, which may be due to an interaction with a ...
1987-05-01
International Nuclear Information System (INIS)
Radiation hardening and radiation-induced chromium (Cr) depletion were related to intergranular stress corrosion cracking (IGSCC) response among various stainless steels (SS). Available data on neutron-irradiated materials were analyzed and correlations developed between fluence, yield strength, grain-boundary Cr concentration, and cracking susceptibility in high-temperature water environments. Large heat-to-heat differences in the critical fluence (0.2 neutrons/cm"2 to 2.5 x 10"2"1 neutrons/cm"2) for IGSCC were documented. Variability often was consistent with yield strength differences among irradiated materials. IGSCC correlated better to yield strength than to fluence for most heats, suggesting a possible role for radiation-induced hardening (and microstructure) on cracking. However, isolated heats revealed a wide range of yield strengths (450 MPa to 800 MPa) necessary to promote IGSCC which could not be explained by ...
Understanding and predicting soot generation in turbulent non-premixed jet flames.
Energy Technology Data Exchange (ETDEWEB)
This report documents the results of a project funded by DoD's Strategic Environmental Research and Development Program (SERDP) on the science behind development of predictive models for soot emission from gas turbine engines. Measurements of soot formation were performed in laminar flat premixed flames and turbulent non-premixed jet flames at 1 atm pressure and in turbulent liquid spray flames under representative conditions for takeoff in a gas turbine engine. The laminar flames and open jet flames used both ethylene and a prevaporized JP-8 surrogate fuel composed of n-dodecane and m-xylene. The pressurized turbulent jet flame measurements used the JP-8 surrogate fuel and compared its combustion and sooting characteristics to a world-average JP-8 fuel sample. The pressurized jet flame measurements demonstrated that the surrogate was representative of JP-8, with a somewhat higher tendency to soot formation. The ...
2010-10-01
International Nuclear Information System (INIS)
We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with ...
2002-07-01
International Nuclear Information System (INIS)
We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with ...
2001-12-21
Thermal diffusivity measurements of irradiated UO_2 pellets
International Nuclear Information System (INIS)
Thermal diffusivity was measured with a laser flash method up to 2000 K for UO_2 pellets irradiated in a commercial reactor. Measurements were done on micro samples of disks (2 mm diameter) or regular prisms (1.5 or 2 mm square cross sections). Thermal diffusivity degraded on extending burnup in agreement with reported values for UO_2 irradiated in test reactors, and it showed hysteresis during the laser flash experiments. Thermal diffusivity began to recover above 750 K and almost completely recovered above 1400 K, which corresponded with the reported radiation damage recovery. The obtained data were in agreement with predictions applying the thermal conductivity expression for irradiated UO_2 proposed by Amaya and Hirai. The sample experiencing power ramp showed higher thermal diffusivity than that of the base irradiated sample and had no obvious hysteresis. This suggested that the radiation damage ...
1998-08-01
International Nuclear Information System (INIS)
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the ...
2000-05-01
High order statistical signatures from source-driven measurements of subcritical fissile systems
Energy Technology Data Exchange (ETDEWEB)
This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility ...
1998-04-01
Edge filter and fringe imaging for laser Doppler wind speed measurement
Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more ...
1997-08-01
The radon therapy - radon inhalatorium in Kowary
International Nuclear Information System (INIS)
In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)
Seasonal variation measurements of radon levels in caves using SSNTD method
Energy Technology Data Exchange (ETDEWEB)
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
2008-08-15
Seasonal variation measurements of radon levels in caves using SSNTD method
International Nuclear Information System (INIS)
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
2008-08-01
Quantitative measurement of elements in a composite, using multienergy gamma-rays
International Nuclear Information System (INIS)
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...
International Nuclear Information System (INIS)
A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.
1987-01-01
QCD corrections to top quark pair production in association with a photon at hadron colliders
We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.
2011-01-01
Neutron resonances in "1"0"0Mo and valence neutron capture
International Nuclear Information System (INIS)
Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.
Application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures
International Nuclear Information System (INIS)
The properties of a new commercial thermoluminescent dosimeter, CaSO4:Dy without a LiF binder (TLD-900) was studied for low-exposure measurements in diagnostic radiology. The former TLD-900 had a LiF binder (herein referred to as ''TLD-900/LiF''). The principle features of this dosimeter are its high sensitivity to low-energy radiation and its relatively low fading which permits measurements down to less than 2.6 X 10(-8) C kg (0.1 mR) with an accuracy better than 20%. The characteristics, annealing procedures, light sensitivity, energy response, reproducibility, and fading, of TLD-900 are discussed and compared with TLD-900/LiF. When the precautions presented in this paper are used, the dosimeters can be used for the measurement of x-ray exposures.
Energy Technology Data Exchange (ETDEWEB)
With an objective to discuss applicability of resistivity imaging using electromagnetic migration to detection of underground cavity, an applicability test was carried out on calculation of a numerical model and measurement data. By using the numerical model, a calculation was performed on a hypothetical case that a cubic cavity with sides each at 40 m exists in a homogenous medium of 200 ohm-m, with the cavity top located 20 m below the ground surface. As a result, it was possible to structure in a very short calculation time an image of the cavity which cannot be identified by one-dimensional inverse analysis. In the case of this cavity, a center of the image was structured on its lower face. It was shown that a location to indicate the image must be changed according to difference in the measurement locations. In a test on data measured in an underground cavity in the city of ...
1997-05-27
The Use of Medical Images in Planning and Delivery of Radiation Therapy
UK PubMed Central (United Kingdom)
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
1997-09-01
Animal Models for Radiation Injury, Protection and Therapy
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
International Nuclear Information System (INIS)
A numerical and experimental investigation is carried out in a solar thermochemical reactor for the thermal dissociation of ZnO at 2000 K using concentrated solar energy. The reactor consists of a cavity-receiver lined with ZnO particles and directly exposed to high-flux irradiation. A transient heat transfer model is formulated to link the rate of radiation, convection, and conduction heat transfer to the reaction kinetics. The radiosity and Monte Carlo methods are applied to obtain the distribution of net radiative fluxes at the internal surfaces of the reactor cavity and at the surface of the ZnO bed. Validation is accomplished in terms of the calculated and measured transient temperature profiles and chemical reaction rates.
2008-04-01
Time-resolved electron-beam characterizations with optical transition radiation
Energy Technology Data Exchange (ETDEWEB)
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
1992-01-01
Time-resolved electron-beam characterizations with optical transition radiation
Energy Technology Data Exchange (ETDEWEB)
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
1992-09-01
Energy Technology Data Exchange (ETDEWEB)
Ford, Bacon, Davis Utah Inc. has reevaluated the Spook site in order to revise the December 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings 48 mi northeast of Casper, in Converse County, Wyoming. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 187,000 tons of tailings at the Spook site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.
1981-10-01
Radiation streaming analysis of horizontal penetrations in calandria vault of TAPP-3, 4
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal penetrations in Calandria Vault of 540 MWe PHWR. There are total 19 penetrations, penetrating east and west walls of calandria vault of 540 MWe PHWR. These penetrations are provided to accommodate ion chambers. HFUs and SDS - 2. Penetrations described here are not present in 220 MWe units except for ion chamber penetrations. As these penetrations are in accessible area, a detailed analysis has been carried out to find out the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out using computer code DOT-III and MCNP. Predictions by this method compare well with the measurements at ion chamber locations at KGS-1,2. (author)
2006-11-13
Radiation damage in A-15 materials: EXAFS studies
International Nuclear Information System (INIS)
EXAFS measurements are useful in determining the local atomic environment of a particular element in a solid. Since there has been some controversy about the nature of the defects produced in A-15 materials by radiation damage, such studies were carried out on some A-15 compounds, V_3Ga which was damaged by neutrons, as well as Nb_3Ge damaged by 2.5 MeV a particles. In the V_3Ga sample, site exchange disorder seems to be the most important result of the neutron damage with less than 20% of the vanadium atoms on wrong sites. However, in the Nb_3Ge samples in addition to site exchange disorder, an unusual splitting of the first near-neighbor distance between the Ge and Nb is found. This splitting, approximately 0.2 A, may explain the large Debye Waller factors observed by Burbank et al.
Photoluminescence enhancement of Sm{sup 3+} ions in the vicinity of noble-metal nanoparticles
Energy Technology Data Exchange (ETDEWEB)
The photoluminescence intensity of an optical emitter changes when placed in close proximity to a noble-metal nanoparticle, due to two contributions. First, the optical near-field of the nanoparticle leads to a change in excitation rate of the emitter. Secondly, the emission efficiency is changed due to an optical energy transfer from the emitter to the metal nanoparticle, which provides additional radiative and non-radiative decay channels. In this work we investigate the photoluminescence of Sm{sup 3+} ions, which are embedded in SiO{sub 2}. The photoluminescence spectrum of ions in proximity to single silver and gold nanoparticles is measured. The influence of the spectral position of the nanoparticle plasmon peak on the photoluminescence yield will be discussed and compared with model calculations.
2009-07-01
Optical properties and up-conversion of Pr"3"+ doped CdS nanoparticles in sol-gel glasses
International Nuclear Information System (INIS)
Silica glasses containing Pr"3"+ with and without CdS nanoparticles were prepared by sol-gel technique. The influence of CdS nanoparticles on Pr"3"+ doped glass was studied by absorption, photoluminescence and up-conversion. From the measured intensities of various absorption bands of these glasses, the Judd-Ofelt parameters ?_2, ?_4 and ?_6 have been evaluated. The radiative transition probability (A), radiative lifetime (?_R), branching ratio (?_R) and integrated emission cross-section (?_P) were calculated from excited states of "3P_1 and "3P_0 levels. The up-conversion emissions were found in the green, orange and red regions under 800 nm excitation with peaks 559, 612 and 688 nm respectively. On excitation with 370 nm also leads to similar green, orange and red regions.
2010-10-01
Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation
An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.
2010-01-01
Further time-resolved electron-beam characterizations with optical transition radiation
Energy Technology Data Exchange (ETDEWEB)
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
1992-01-01
Further time-resolved electron-beam characterizations with optical transition radiation
Energy Technology Data Exchange (ETDEWEB)
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
1992-12-31
Fourier analysis of energy transfer data obtained by simulating a 14-MeV #alpha#-particle in water
International Nuclear Information System (INIS)
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
2010-01-15
Estimating extreme values of thermal gradients in concrete structures
British Library Electronic Table of Contents (United Kingdom)
Temperature variations due to climate changes are a major cause of movements in a concrete structure, both in the longitudinal and transversal directions and between different parts of the structure. If these movements are restrained, stresses will be induced which may contribute to cracking. The movements are caused by complex interactions of several factors such as solar radiation, air temperature, long-wave heat radiation and wind speed. To predict the varying thermal conditions in a concrete structure a finite element model has been used. A validation of the model has been performed using field measurements in a concrete slab together with climate data from the Swedish Meteorological and Hydrological Institute to be able to use the model for simulations over long time periods and for s...
2011-01-01
Engineering assessment of inactive uranium mill tailings, Tuba City site, Tuba City, Arizona
Energy Technology Data Exchange (ETDEWEB)
Ford, Bacon and Davis Utah Inc. has reevaluated the Tuba City site in order to revise the March 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings at Tuba City, Arizona. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 0.8 million tons of tailings at the Tuba City site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.
1981-09-01
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
2003-04-08
Effects of stress on radiation hardening and microstructural evolution in A533B steel
British Library Electronic Table of Contents (United Kingdom)
Bent specimens of A533B steel (0.16wt% Cu) were irradiated at 290degreeC to 1dpa with 6.4MeV Fe3+ ions. Calculated tensile stresses at the irradiated surface were set to 0, 250, 500 and 750MPa. The specimens were subjected to hardness measurements, transmission electron microscopy (TEM) observations and three-dimensional atom probe (3DAP) analysis. The radiation-induced hardening decreased with increasing stress to 500MPa which was near the yield strength. TEM and 3DAP results showed that well-defined dislocation loops and solute clusters were formed. The diameter of dislocation loops increased and the number density decreased when the stress was applied, whereas the diameter and number density of solute clusters decreased. The hardening was mainly attributed to solute cluster formation. A...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...
2009-01-01
Design concept for radiation hardening of low power and low voltage dynamic memories
International Nuclear Information System (INIS)
A radiation hard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study.
International Nuclear Information System (INIS)
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
1987-01-01
Channeling studies of radiation damage in metal-silicides
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.
1978-01-01
Channeling studies of radiation damage in metal-silicides
International Nuclear Information System (INIS)
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.
British Library Electronic Table of Contents (United Kingdom)
Abstract A miniaturized spatial temperature gradient CE system with automated sample introduction for DNA mutation detection was established. Continuous electrokinetic sample injection was achieved by combining an automated slotted vial array sample introduction device to the spatial temperature gradient CE system. The temperature gradient was produced by a radiative heating system with a single graphite block heater, and the stability of the temperature gradient was investigated. The temperature variation of each measure point was 0.12 0.21% RSD (n=7) within 6 h. A 14 cm Teflon AF coated silica capillary was used both as the separation channel and as the liquid core waveguide tube of fluorescence signal. Under a temperature gradient from 54.8 to 59.5 C, a low range control mutation standa...
2010-01-01
Moessbauer diffraction measurements on polycrystalline bcc iron
Energy Technology Data Exchange (ETDEWEB)
In the early days of Moessbauer spectroscopy, it was demonstrated that coherent scattering of photons emitted by a Moessbauer source can be observed. In spite of the fact that scattering experiments could give information not accessible by the absorption method, they are not widely used. The reasons for this are, on the one hand, experimental difficulties, and on the other hand, the form of the samples, which should be large single crystals in most cases. In this work, we present a Moessbauer diffraction measurement on polycrystalline bcc iron where these problems have been overcome. We demonstrate that using the kinematical theory of gamma-ray diffraction, useful information on the relative orientation of the crystallographic axis to the hyperfine field directions can be subtracted. (orig.)
1994-11-01
Energy Technology Data Exchange (ETDEWEB)
The susceptibility to intergranular corrosion of different heats of Alloy 800 was evaluated by three different methods: the ASTM A 262 Practice E (or modified Strauss test), the Electrochemical Potentiokinetic Reactivation method, and by magnetic-susceptibility measurements. Reasonably good agreement was found between the sensitization areas as defined by the three methods in the TTS diagrams. In some cases the area defined by the Strauss test was slightly smaller than that determined by the other two tests. The differences might be explained by the fact that the methods present different sensitivities to the chromium concentration at the grain boundaries. 27 references, 11 figures, 3 tables.
1982-01-01
Conversion of selected military forces to the use of metric measurement units
Conversion of the United States military to the International System of measurement units is in the very early stages. Little formal planning has been done to articulate the management required to complete the conversion of operational Army and Air Force units. For those operational forces tasked to provide continuous combat readiness throughout metrication, management problems associated with the conversion are particularly difficult because of the nature of these assigned missions. This is the case for the 82nd Airborne Division ready brigade force (DRB) and the Military Airlift Command (MAC) strategic airlift system operating the C-141 and C-5A aircraft.
1976-06-01
Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles
International Nuclear Information System (INIS)
Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes
Energy Technology Data Exchange (ETDEWEB)
The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise ...
1990-05-01
Stereotactic iridium-192 interstitial brachytherapy for intracranial malignant tumors
International Nuclear Information System (INIS)
The results of interstitial brachytherapy in 13 patients with malignant brain tumors (malignant glioma 9 cases, metastatic brain tumor 4 cases) were reported. In all patients, Ir-192 thin wires were implanted temporarily in afterloading catheters, which were implanted appropriately by means of MRI or CT guided stereotactic technique. Clinical results on CT scan were as follows: CR (complete response) 1 case, PR (partial response) 6 cases and NC (no change) 6 cases. Even in the NC group, tumor growth was inhibited temporarily. Tumor free intervals were ranged 2-17 months. In early series, the intervals were about 2 months due to incomplete arrangement of radioactive implants. In recent series, prolongation of tumor free interval more than 12 months was achieved due to precise arrangements of implants. MRI guided stereotactic interstitial brachytherapy may provide safe and precise ...
1990-01-01
The analysis of coupled heat and particle transport in Tokamaks by means of Fourier transform
Energy Technology Data Exchange (ETDEWEB)
A method to deduce the 2 x 2 transport matrix for coupled heat and particle transport in Tokamaks is proposed. The method applies to perturbative experiments, and is based on a Fourier transform of the measured signals of temperature and density. By analyzing different linear combinations of temperature and density, the eigenvectors and eigenvalues of the transport matrix are determined. The method is tested for a number of illustrative cases using simulated data, and the sensitivity to noise on the signals is evaluated. (author).
1992-04-01
Oscillations in radioactive exponential decay
Energy Technology Data Exchange (ETDEWEB)
Several older and recent reports provided evidence for the oscillatory character of the exponential decay law in radioactive decay and attempted to explain it with basic physics. We show here that the measured effects observed in some of the cases, namely in the decay of {sup 226}Ra, {sup 32}Si in equilibrium, and {sup 36}Cl, can be explained with the temperature variations.
2009-05-25
International Nuclear Information System (INIS)
Comparison of plasma density increase was carried out in outer and inner channels of the interferometer in T-11M tokamak. There were two cases of gas puffing: by outer valve or upper one. Amplitude of difference of the plasma density increase consisted of 9% near the outer valve. Perturbation of the electric potential e?1/Te can have similar value. This perturbation can lead to appearance of the additional losses.
2006-01-01
Nuclear methods monitor nutrition
International Nuclear Information System (INIS)
Neutron activation of nitrogen and hydrogen in the body, the isotope dilution technique and the measurement of naturally radioactive potassium in the body are among the new nuclear methods, now under collaborative development by the Australian Nuclear Scientific and Technology Organization and medical specialists from several Sydney hospitals. These methods allow medical specialists to monitor the patient's response to various diets and dietary treatments in cases of cystic fibrosis, anorexia nervosa, long-term surgical trauma, renal diseases and AIDS. ills.
New Reactor Neutrino Experiments besides Double-CHOOZ
Several new reactor neutrino experiments are being considered to measure the parameter theta-13. The current plans for Angra, Braidwood, Daya Bay, KASKA and KR2DET are reviewed. A case is made that, together with Double-CHOOZ, a future world program should include at least three such experiments.
2005-01-01
...] Transmission of Exchange Rate Shocks into Domestic Inflation: The Case of the Czech Republic by Oxana Babetskaia-Kukharchuk [Downloadable!] Measuring the Financial Markets' Perception of EMU Enlargement: The Role of Ambiguity Aversion by Martin Cincibuch & Martina Hornikova [Downloadable!] Inflation Targeting and Communication: Should the Public Read Inflation Reports or Tea Leaves? by Ales Bulir & Katerina Smidkova & ...
International Nuclear Information System (INIS)
Heavy metals (Pb, Cd, Mn, Cu, Zn, Fe) were determined in surface waters in the surroundings of the depositories of the mining shrubs in the region of Banska Stiavnica (SR) by radionuclide X-ray fluorescence analysis. Allowed concentrations of the determined metals are exceeded numerously (multiplicity in some cases was 10"3-10"6). (author).
1997-01-01
Deep drawing and impact extrusion of magnesium alloys at room temperature
Energy Technology Data Exchange (ETDEWEB)
Magnesium alloys and composites are potentially highly attractive materials for lightweight design in the automotive industry - if common forming technologies, i.e., deep drawing and cold extrusion, are applicable to them; so far, this is seldom the case. The authors have tested some candidate Mg alloys and discuss the results of their measurements in detail. The Figure shows a typical workpiece part obtained by a deep-drawing technique. (Abstract Copyright [2003], Wiley Periodicals, Inc.)
2003-04-01
Coal uses and upgrading processes
Energy Technology Data Exchange (ETDEWEB)
The paper discusses the status of coal as a raw material and energy source. After referring to coal preparation and the costs it involves the author deals with coal/liquid suspensions and their fueling uses. Access is given to different aspects concerning the use of coal for electric power and heat generation. They include pollution abatement measures, economic analyses and fuel engineering in the case of coal. Further sections are dedicated to upgrading procedures such as the gasification, liquefaction and coking of coal. A bibliography informs the reader about further publications available on the subject. (HAG).
1986-04-01
Anomalous solvent extraction behavior of astatine
International Nuclear Information System (INIS)
We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
Energy Technology Data Exchange (ETDEWEB)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)
1993-10-01
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
International Nuclear Information System (INIS)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).
Energy Technology Data Exchange (ETDEWEB)
The acceptances to be obtained during the first operational run, refer to measures proving the functional integrity of the turbine control system and assuring the compliance with the maximum allowable overspeed in case of lead changes or perturbations. The Guideline concerns essentially speed, power, and pressure controllers coupled to generators. It may be appropriately extended to steam turbines serving other purposes.
1983-01-01
A case of noble gas leakage searching and analysis in Daya Bay NPP
International Nuclear Information System (INIS)
The author reports briefly a noble gas leakage searching process in which a person was contaminated in Daya Bay NPP, the radionuclide causing contamination was ascertained as the daughter product of "8"8Kr, the "8"8Rb; By taking air contamination sampling and measuring the "8"8Rb concentration in the room, the leakage source was predetermined and the leakage rate of primary coolant was estimated
1999-09-01
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 ...
A detailed analysis of the properties of radiolyzed proteinaceous amino acids
International Nuclear Information System (INIS)
The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. ...
2011-03-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in ...
2009-10-15
Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis
International Nuclear Information System (INIS)
The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including ...
2003-06-01
Dependence of Energy Thresholds on Laser Radiation Wavelength in Initiation of Heavy Metal Azides
The behavior of silver and lead azides (scaly and threadlike crystals, and compacted powders) in initiation of explosive decomposition by laser pulsed radiation has been investigated. Initiation energy thresholds in irradiation at wavelengths of 1064 nm, 532 nm, 354.7 nm, 266 nm corresponding to four laser radiation harmonics have been measured. Samples both uncovered and covered with a transparent dielectric (a quartz plate) with the compressive force of up to 0.5GPa were initiated. In the transparent spectral region (the first and second laser harmonics) of the heavy metal azide matrix the effect of covering the sample surface with a plate on initiation energy threshold was insignificant, whereas, in the region of bandgap absorption (the fourth harmonic) strong dependence of the initiation threshold on whether the surface under irradiation is uncovered or covered. The results obtained have been considered with the account ...
2010-01-01
We compare the predictions of four different algorithms for the distribution of ionized gas during the Epoch of Reionization. These algorithms are all used to run a 100 Mpc/h simulation of reionization with the same initial conditions. Two of the algorithms are state-of-the-art ray-tracing radiative transfer codes that use disparate methods to calculate the ionization history. The other two algorithms are fast but more approximate schemes based on iterative application of a smoothing filter to the underlying source and density fields. We compare these algorithms' resulting ionization and 21 cm fields using several different statistical measures. The two radiative transfer schemes are in excellent agreement with each other (with the cross-correlation coefficient of the ionization fields >0.8 for k 0.6 for k < 1 h/Mpc). When used to predict the 21cm power spectrum at different times during reionization, all ionization ...
2010-01-01
Adaptive response of the chicken embryo to low doses of x-irradiation
Energy Technology Data Exchange (ETDEWEB)
Chicken embryos were x-irradiated in ovo with 5-30 cGy (=priming dose) at the 13th-15th day of development. After 3-48 h, brain- and liver-cell suspensions were x-irradiated in vitro with (challenge) doses of 4-32 Gy. Significantly less radiation damage was observed when the radiation response was measured by scheduled DNA synthesis, nucleoid sedimentation and viscosity of alkaline cell lysates 12-36 h after the priming exposure. In vivo, pre-irradiation with 10 cGy enhanced regeneration as evidenced by the DNA content of chicken embryo brain and liver 24 h following a challenge dose of 4 Gy. From nucleoid sedimentation analyses in brain and liver cells immediately after irradiation with 16 Gy and after a 30-min repair period in the presence of aphidicolin, dideoxythymidine and 3-aminobenzamide or in the absence of these DNA repair inhibitors, it is concluded that a reduction of the initial radiation ...
1995-08-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.