WorldWideScience
1

Linac Coherent Light Source (LCLS) Bunch-Length Monitor using Coherent Radiation  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is a SASE x-ray Free-Electron Laser (FEL) based on the final kilometer of the Stanford Linear Accelerator. One of the most critical diagnostic devices is the bunch length monitor (BLM), which is to be installed right after each compressor utilizing coherent radiation from the last bending magnet. We describe the components and the optical layout of such a BLM. Based on the setup geometry, we discuss some issues about the coherent radiation signal.

2007-03-21

2

Overview of bunch length measurements.  

Energy Technology Data Exchange (ETDEWEB)

An overview of particle and photon beam bunch length measurements is presented in the context of free-electron laser (FEL) challenges. Particle-beam peak current is a critical factor in obtaining adequate FEL gain for both oscillators and self-amplified spontaneous emission (SASE) devices. Since measurement of charge is a standard measurement, the bunch length becomes the key issue for ultrashort bunches. Both time-domain and frequency-domain techniques are presented in the context of using electromagnetic radiation over eight orders of magnitude in wavelength. In addition, the measurement of microbunching in a micropulse is addressed.

1999-02-19

3

Interference phenomena at the elastic collision of atoms with formation of the Feshbach resonance in the presence of laser radiation field  

British Library Electronic Table of Contents (United Kingdom)

Resonant scattering of atoms with formation of the Feshbach resonance in the presence of a laser radiation coupling the levels of two bound atoms (a molecule) is considered. The laser field leads to a second resonance in scattering and broadening of resonances, which facilitates the possibility of experimental observation of asymmetry of the total scattering cross-section arising because of interference between resonant and potential scatterings. The effects associated with interference of the two channels of decay of a bound system of two atoms (a molecule) in the laser field are studied. An expression is obtained for the scattering length in collision of two cold atoms in the field of laser radiation.

2011-01-01

4

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).

5

Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity  

CERN Document Server

We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca ...

2011-01-01

6

Free electron laser inertial thermonuclear synthesis  

International Nuclear Information System (INIS)

The paper proposes a concept of power driver for industrial thermonuclear reactor based on inertial thermonuclear synthesis (ITS). The circuit is based on the application of free electron laser (FEL) as a energy source for thermonuclear target compression which becomes feasible due to the application of a radically new circuit of FEL-amplifier. In the project under consideration the FEL-based laser system operates on the wave length of 0.5 micrometer. The full energy of laser radiation equals 1 MJ. This energy is delivered to the target in the pulse whose length is controlled within the range of 0.1-2 ns. The laser system brightness is 4 x 10"2"2 W cm"-"2. The FEL operating pulse repetition frequency is 40 Hz, full efficiency of electricity conversion into the energy of optical radiation is 11%. 9 refs., 3 figs., 2 tabs.

7

Radiation: how safe is safe?  

International Nuclear Information System (INIS)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).

1993-05-01

8

Radiation: how safe is safe  

Energy Technology Data Exchange (ETDEWEB)

Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).

1993-05-15

9

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

10

Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.

2005-06-15

11

Fluctuations of the energy of Stokes pulses of resonance coherent SRS  

International Nuclear Information System (INIS)

An analytic solution is obtained for the equations of resonance coherent SRS by neglecting the population of the final level of the Raman transition for the systems with the active-medium length that is smaller than the wavelength of the incident light. For the extended systems, a numerical solution is obtained. The energy distribution of the Stokes pulses is found. The large-scale (about 100%) fluctuations of the Stokes radiation energy were observed in the case of unsaturated amplified spontaneous emission. (nonlinear optical phenomena)

2000-11-30

12

On the space-time scales of the surface solar radiation field  

Energy Technology Data Exchange (ETDEWEB)

The characteristic space-time scales of surface solar radiation fields measured by the 111-instrument ME-SONET in Oklahoma are estimated after removal of the diurnal cycle. These estimates of {open_quotes}within-day{close_quotes} are used to deduce the representativeness of surface solar radiation measurements measurement site as a function of time-averaging interval. Nomograms of the relation between point measurements and area averages are given for different space-time-averaging intervals. Examples from the nomograms show, for instance, that under conditions of low mean radiation (cloudy days), the central site point measurements are representative of a spatial area the size of a T42 GCM grid box (280 km X 280 km) if one uses hourly averages and is willing to accept a correlation of 0.45 between area average and point measurement. The point data represent a 60 km X 60 km region at a 0.90 correlation level if a 5-min time ...

1998-01-01

13

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the {lambda}=41.8-nm transition of Xe IX in plasma  

Science.gov (United States)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,{tau}) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe{sup 8+}. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe{sup 8+} transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

14

Theoretical search for optimal pump parameters for observing spontaneous radiation amplification on the ?=41.8-nm transition of Xe IX in plasma  

International Nuclear Information System (INIS)

Based on a collisional-radiative model, an atomic-kinetic calculation of the gains on the 41.8-nm transitions of Pd-like xenon was performed for the plasma produced due to the interaction of a femtosecond laser pulse with gaseous xenon. The gains g(z,?) averaged over the spatial and temporal coordinates were compared with the known gains which had been measured experimentally in Xe8+. The amplification was shown to occur under the conditions of ionisation of the working ions, and the time of output radiation saturation depends on the time of Xe8+ transformation to higher-ionised ions. Our theoretical investigation enables determining the optimal pump parameters, at which the product of the gain g by the active medium length L is about 20, which exceeds the experimental gL value. (active media)

2004-11-30

15

Study on prepartion of polyethylene ion-exchange capillary by radiation induced graft co-polymerization  

International Nuclear Information System (INIS)

The synthetic process of polyethylene cation exchange capillary via radiation grafting polystyrene by simultaneous irradiation with "6"0Co #gamma#-ray source and sulfonation with concentrated H_2SO_4 was studied. The effects of dose, dose rate, monomer concentration, solvents, temperature and crosslinking agents on the graft copolymerization of styrene with polyethylene capillary were illustrated. The relationship between the radiation grafting conditions and the properties of ion-exchange capillary were examined. A polyethylene cation exchange capillary with I.D. 0.8 mm, length 20 m, exchange capacity 0.7 Meq/g 60% capacity in 10 s (flow rate 20 ml/min) was prepared. No significant loss of copacity was found from this ion-exchange capillary after 200 adsorption/regeneration cycles.

16

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

17

An off-axis Cassegrain optimal design for short focal length parabolic solar concentrators  

Energy Technology Data Exchange (ETDEWEB)

The present work addresses an off-axis Cassegrain optical concentration system. The specific primary collector analyzed, a short focal length parabolic concentrator, is at the University of Florida`s Energy Park. A secondary hyperbolic reflective element was designed to redirect the solar radiation from the primary focal plane to an off-axis target on the polar axis of the primary concentrator. This ground level target will be required for planned experimental work. The analysis was performed using a numerical ray tracing procedure that incorporates both random and systematic errors due to slope and surface irregularities. The optimization process varied secondary element size, curvature, and offset angle, and yielded information required for optimum design. As a single secondary element was found impractical, three elements were designed for use at various time of the year. The numerical analysis predicts that typically 70 to 75 percent of the ...

1995-02-01

18

Development of a pump-probe facility combining a far-infrared source with laser-like characteristics and a VUV free electron laser  

International Nuclear Information System (INIS)

The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum ...

2001-12-21

19

Radiation and thermal analysis of superconducting quadrupoles in the interaction region of linear collider  

Energy Technology Data Exchange (ETDEWEB)

CERN has encouraged the US-LARP collaboration to participate in Phase I of the LHC luminosity upgrade by analyzing the benefits gained by using Nb3Sn technology to replace the functionality of select NbTi magnets that CERN is committed to construct. Early studies have shown that the much higher gradients (shorter magnetic lengths) and temperature margins (quench stability) of Nb3Sn magnets compared to their NbTi counterparts is favorable--allowing the insertion of additional absorbers between Q1 and Q2, for example. This paper discusses the relative merits of the NbTi and Nb3Sn options.

2008-06-01

20

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-01-01

21

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-09-01

22

Network simulation method applied to radiation and viscous dissipation effects on MHD unsteady free convection over vertical porous plate  

British Library Electronic Table of Contents (United Kingdom)

The effects of thermal radiation and viscous dissipation on magneto-hydrodynamic (MHD) unsteady free-convection flow over a semi-infinite vertical porous plate are analysed. The fluid considered is non-gray (absorption coefficient dependent on wave length). The Network Simulation Method is used to solve the boundary-layer equations based on the finite-difference formulation; only discretization of the spatial co-ordinates is necessary, while time remains as a real continuous variable. This method provides a solution for both transient and steady-state problems at the same time, and programming does not require manipulation of the sophisticated mathematical software that is inherent in other numerical methods. The velocity, temperature, local skin-friction and local Nusselt number are studi...

2007-01-01

23

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...

2007-01-01

24

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-01-01

25

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-12-31

26

Precision Measurement of the Undulator K Parameter using Spontaneous Radiation  

Energy Technology Data Exchange (ETDEWEB)

Obtaining precise values of the undulator parameter, K, is critical for producing high-gain FEL radiation. At the LCLS [1], where the FEL wavelength reaches down to 1.5 {angstrom}, the relative precision of K must satisfy ({Delta}K/K){sub rms} {approx}< 0.015% over the full length of the undulator. Transverse misalignments, construction errors, radiation damage, and temperature variations all contribute to errors in the mean K values among the undulator segments. It is therefore important to develop some means to measure relative K values, after installation and alignment. We propose a method using the angle-integrated spontaneous radiation spectrum of two nearby undulator segments, and the natural shot-to-shot energy jitter of the electron beam. Simulation of this scheme is presented using both ideal and measured undulator fields. By ''leap-frogging'' to ...

2007-04-17

27

The review of radioactive waste management in the world  

International Nuclear Information System (INIS)

Radioactive waste is generally classified on the basis of how much radiation and the type of radiation it emits as well as the length of time over which it will continue to emit radiation. Many activities dealing with radioactive materials produce nuclear wastes, including civilian nuclear power programs (nuclear Power plant operations and nuclear fuel-cycle activities), defense nuclear programs (nuclear weapons production, naval nuclear reactor programs, and related R and D), and industrial and institutional activities (scientific research, medical operations, and other industrial uses of Radioisotopic sources or Radio chemicals). To minimize the potential adverse health and environment impacts to people and other systems including of animals, plant and etc, during the entire lifetime of the radionuclides involved, nuclear waste must be carefully and properly managed. The scope of nuclear - waste ...

28

Nonlinear pulse evolution in seeded free-electron laser amplifiers and in free-electron laser cascades  

International Nuclear Information System (INIS)

The advances in laser technology have made available very short and intense laser pulses which can be used to seed a high-gain single-pass free-electron laser (FEL) amplifier. With these seed pulses, a regime of the FEL interaction where the radiation evolution is simultaneously dominated by nonlinear effects (saturation) and time-dependent effects (slippage) can be explored. This regime is characterized by the propagation of a solitary wavelike pulse where the power of the optical wave grows quadratically with time, its pulse length decreases and the spectral bandwidth increases. We analyze the interplay between the field and particle dynamics of this propagation regime which was studied before and termed super-radiance. Furthermore we analyze the properties of the strong higher-order harmonic emission from this wave and its behavior when propagating in a cascade FEL. The super-radiant pulse is indeed capable of passing through the stages of a ...

2005-08-15

29

Improvement of the crossed undulator design for effective circular polarization control in X-ray FELs  

CERN Document Server

The production of X-ray radiation with a high degree of circular polarization constitutes an important goal at XFEL facilities. A simple scheme to obtain circular polarization control with crossed undulators has been proposed so far. In its simplest configuration the crossed undulators consist of pair of short planar undulators in crossed position separated by an electromagnetic phase shifter. An advantage of this configuration is a fast helicity switching. A drawback is that a high degree of circular polarization (over 90%) can only be achieved for lengths of the insertion devices significantly shorter than the gain length, i.e. at output power significantly lower than the saturation power level. The obvious and technically possible extension considered in this paper, is to use a setup with two or more crossed undulators separated by phase shifters. This cascade crossed undulator scheme is distinguished, in performance, by ...

2011-01-01

30

High extraction efficiency observed at the JAERI free-electron laser  

International Nuclear Information System (INIS)

A high power Free-Electron Laser (FEL) has lased at a wavelength of 22 #mu#m at the Japan Atomic Energy Research Institute (JAERI). The maximum power on a macro-pulse average is 1.7 kW, and it corresponds to an FEL energy of 160 #mu#J/micro-pulse. Extraction efficiency from the electron beam to the FEL radiation was measured to be 5.3% by an energy analyzer, when the maximum FEL power was coupled out. The rms wavelength spread was measured to be 4.6% at the same time. The extraction efficiency, in general, has a maximum value near the zero detuning length of an optical cavity, where (in contrast) the single-pass gain becomes smallest. A high peak current and a long macro-pulse duration are therefore indispensable for realizing high efficiency. The electron beam energy is 16.5 MeV, and the average current is 5.3 mA at a micro-pulse repetition rate of 10.4 MHz. The macro-pulse duration is 500 #mu#s (5000 micro-pulses), long enough to reach ...

2001-12-21

31

Venus surface power and cooling systems  

British Library Electronic Table of Contents (United Kingdom)

A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...

2007-01-01

32

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

33

Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)  

Energy Technology Data Exchange (ETDEWEB)

The LCLS, a Free-Electron Laser (FEL) designed for operation at a first harmonic energy of 300 eV ({lambda} {congruent} 40{Angstrom}) in the Self-Amplified Spontaneous Emission (SASE) regime, will utilize electron bunches compressed down to durations of <0.5ps, or lengths of <150 {mu}. It is natural to inquire whether coherent radiation of this (and longer) wavelength will constitute a significant component of the total coherent output of the FEL. In this paper a determination of a simple upper bound on the IR that can be generated by the compressed bunches is outlines. Under the assumed operating parameters of the LCLS undulator, it is shown that that IR component of the coherent output should be strongly dominated by the x-ray component.

1993-05-01

34

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

35

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative error of less than 10%.

1981-10-01

36

Visible light emitting vertical cavity surface emitting lasers  

Science.gov (United States)

A vertical cavity surface emitting laser that emits visible radiation is built upon a substrate, then having mirrors, the first mirror on top of the substrate; both sets of mirrors being a distributed Bragg reflector of either dielectrics or other materials which affect the resistivity or of semiconductors, such that the structure within the mirror comprises a plurality of sets, each having a thickness of {lambda}/2n where n is the index of refraction of each of the sets; each of the mirrors adjacent to spacers which are on either side of an optically active bulk or quantum well layer; and the spacers and the optically active layer are from one of the following material systems: In{sub z}(Al{sub y}Ga{sub 1{minus}y}){sub 1{minus}z}P, InAlGaAs, AlGaAs, InGaAs, or AlGaP/GaP, wherein the optically active region having a length equal to m {lambda}/2n{sub eff} where m is an integer and n{sub eff} is the effective index of refraction of the laser ...

1995-06-27

37

Study of the Smith-Purcell effect in the relativistic regime  

International Nuclear Information System (INIS)

We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have yielded 10 mA pulses with a width of about 20 ...

1995-08-21

38

Optimizing the design of solar energy greenhouses  

Energy Technology Data Exchange (ETDEWEB)

In Canada, the cost of heating is a major expense in the operation of greenhouses in the winter season, inhibiting greenhouse production in winter months in most part of the country. Alternative energy sources, such as solar energy and biomass energy may offer an economically feasible heating alternative. A solar energy greenhouse technology developed in northern China for winter vegetable production has demonstrated good potential for Manitoba winter conditions. The design and performance of solar energy greenhouses depend on the geographical location. Therefore, in order to optimize the design of solar greenhouses with respect to the latitude of the location for maximum solar radiation gain, a theoretical analysis was performed that analyzed parameters such as greenhouse length and the roof slope. This paper described the methodology of the study, including a description of solar energy greenhouses; the energy of solar ...

2006-07-01

39

Interaction of free fatty acids with the erythrocyte membrane as affected by hyperthermia and ionizing radiation  

Energy Technology Data Exchange (ETDEWEB)

The interference of hyperthermia and ionizing radiation, respectively, with the effects of capric (10:0), lauric (12:0), myristic (14:0), oleic (cis-18:1) and elaidic (trans-18:1) acids on the osmotic resistance of human erythrocytes was investigated. The results are summarized as follows: (A) not only at 37 degrees, but also at 42 and 47{degrees}C lauric acid (12:0) represents the minimum chain length for the biphasic behaviour of protecting against hypotonic hemolysis at a certain lower concentration range and hemolysis promotion at subsequent higher concentrations; (B) with increasing temperatures the protecting as well as the hemolytic effects occur at lower concentrations of the fatty acids; (C) the increase of temperature promotes the extent of hemolysis and reduces the extent of protection against hypotonic hemolysis; (D) Gamma-irradiation of erythrocytes selectively affects the concentration of oleic acid at which maximum protection ...

1990-04-01

40

Influence of the circadian rhythm in cell division on radiation-induced mitotic delay in vivo  

Energy Technology Data Exchange (ETDEWEB)

Mitotic delay is described as a classical response to radiation; however, circadian rhythmicity in cell division in vivo has not been considered by many authors. The present study investigated the relation between fluctuations reported as mitotic delay and recovery in vivo and circadian oscillations in mitotic index in mouse corneal epithelium. One aspect involved single doses (approximately 600 rad) given to mice at different circadian stages. The normal circadian rhythm in cell division was never obliterated. Inhibition of mitosis was evident but unpredictable, ranging from 6 to 15 hr after irradiation. Recovery was evident only during the daily increase in mitotic index of controls. The classical interpretation of recovery from mitotic delay may be in an in vitro phenomenon not reflecting in vivo responses, which are apparently strongly circadian stage dependent. The second portion of the study demonstrated a dose-response effect on length ...

1982-01-01

41

Experimental study of the premixed combustion within the nonhomogeneous porous ceramic media  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of premixed methane-air combustion within the one-dimensional porous ceramic burners for various burner configurations is presented. The burner is nonhomogeneous because of different pore size ceramic block used in different section of the burner. Therefore, the thermophysical and transport properties are nonuniform along the burner core length. The burners are constructed of partially stabilized zirconia. The CO and NO{sub x} emissions, flame speed, and flame stability are examined and compared at lean equivalence ratios for five different burner configurations. The sandwich-structured burner has very favorable flame stabilizing characteristic due to the radiation reflecting region. While the combustion proceeds at faster rate than other burner configurations, the radiation reflecting region and the exit surface have low temperature. Thus the NO{sub x} emission can be kept at the same low ...

1996-12-01

42

Development of fire simulation models for radiative heat transfer and probabilistic risk assessment  

Energy Technology Data Exchange (ETDEWEB)

An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical applications, advanced ...

2008-07-01

43

The dependence of photovoltage of the system APhV-films photoresistor on the capacity of X-ray radiation dose  

International Nuclear Information System (INIS)

Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum slanting ...

2004-08-23

44

NASA Technical Paper 3487 ... - NASA Technical Reports Server  

Science.gov (United States)

heat transfer augmentation was found to increase with decreasing length scale but no optimum length scale was found. Heat transfer augmentation due to turbu- ...

45

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

46

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

47
48

The free electron laser klystron amplifier concept  

International Nuclear Information System (INIS)

The simplest high gain free electron laser (FEL) amplifier concept is proposed. A klystron amplifier has the useful property that the various electronic processes take place in separate portions of the amplifier, rather than overlapping as in FEL amplifier with an uniform undulator. The klystron consists of two fundamental parts: succession of 2-3 cascades (modulator), and an output undulator (radiator) in which the modulated electron beam coherently radiates. Each cascade consists of uniform undulator and dispersion section. Unlike distributed optical klystrons, we have a high gain per cascade pass. This has a few consequences. First, klystron gain does not depend on the bunch compression in the injector linac, i.e. maximum gain per cascade pass at high peak beam current is the same at low peak beam current, without compression. Conventional, short-wavelength FEL amplifier and distributed optical klystron require electron beam peak current of ...

49

Electron-beam induced RAFT-graft polymerization of poly(acrylic acid) onto PVDF  

Energy Technology Data Exchange (ETDEWEB)

This paper explores for the first time the post-radiation-induced-graft polymerization on solid substrate using reversible addition-fragmentation transfer (RAFT) mechanism. Radiation-induced graft polymerization onto polymers is a potentially interesting technique to create easily new materials from highly resistant polymers, e.g. surface graft polymerization of acrylic acid (AA) onto poly(vinylidene difluoride) (PVDF) improves its surface properties without losing its excellent mechanical properties. As a consequence of the radical nature of the polymerization processes it is difficult to control molecular weight of grafted chains, and therefore design and standardize the properties of the final product. RAFT polymerization is a suitable method to obtain monodisperse polymers. The ability of the RAFT agents to control the polymer chain length could be an interesting approach to improve the grafted polymers obtained by ...

2005-07-01

50

Short rotation coppice harvesting: an evaluation of the Salix Maskiner Bender III  

Energy Technology Data Exchange (ETDEWEB)

Version III of the Salix Maskiner ``Bender`` coppice harvester was used to successfully harvest 11.2 hectares of short rotation poplar and willow coppice in February 1997. On a wide range of typical UK crop and site conditions, the Swedish harvester was shown to have productivity rates ranging from 4.28 to 7.97 odt/smh. Based on a total system cost of Pound 81.26 per scheduled machine hour, the Bender III is able to produce wood chip for between Pound 10.20 and pound 18.97 per dry tonne. The variation in machine productivity is dependent on crop productivity and working method, emphasising the importance of site design in optimising system efficiency. In willow crops the wood chip produced by the Bender III contained a significant amount of material greater than 75mm in length. The bulk of the chips however, fell into the 5-45mm category with only a very limited amount of fine materials less than 5mm in length. The chips from poplar crops were ...

1997-12-31

51

Deterministic calculations of radiation doses from brachytherapy seeds  

International Nuclear Information System (INIS)

Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software also allows the isodose visualization at the surface plan. The user can choose ...

2003-08-17

54

X-radiation effects on muscle cell membrane electrical parameters  

International Nuclear Information System (INIS)

Early effects of 100 Kilorads of X-rays on muscle cell membrane properties have been measured in sartorius muscles from Leptodactylus ocellatus. Threshold strength for rectangular current pulses increased 10% after irradiation, and action potential propagation velocity decreased 10%. Passive membrane parameters were calculated from potential responses to sub-threshold current pulses, assuming conventional cable theory. Specific membrane conductance increased to 18% after irradiation, membrane capacitance increased 14%, and length constant decreased 10% but membrane time constant was unchanged. Cell diameter decreased 5%, and resting membrane potential decreased 8%. Membrane parameters during an action potential were also evaluated by the phase-plane and current-voltage plot techniques. Irradiation significantly decreased the action potential amplitude, the excitation potential, and the maximum rates of rise and fall of membrane potential. Increases were observed in ...

55

VUV efficiency and radiant emittance characterization of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and discharge tube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. Modeling of the xenon positive column discharge yields radiant emittance and efficiency ...

1996-12-31

56

Simulations and Analytic Calculations of Bubble Growth During Hydrogen Reionization  

CERN Document Server

We present results from a large volume simulation of Hydrogen reionization. We combine 3d radiative transfer calculations and an N-body simulation, describing structure formation in the IGM, to detail the growth of HII regions around high redshift galaxies. Our simulation tracks 1024^3 dark matter particles, in a box of side length 65.6 Mpc/h. This large volume allows us to accurately characterize the size distribution of HII regions throughout most of the reionization process. At the same time, our simulation resolves many of the small galaxies likely responsible for reionization. It confirms a picture anticipated by analytic models: HII regions grow collectively around highly-clustered sources, and have a well-defined characteristic size, evolving from a sub-Mpc scale at the beginning of reionization to R>10 Mpc towards the end. We present a detailed statistical description of our results, and compare them with a numerical hybrid scheme ...

2006-01-01

57

Radon-mitigation in buildings  

International Nuclear Information System (INIS)

From the indoor radon problem arises a great challenge for the radiation protection of the population. The soil can be considered as the only source for high radon concentrations in buildings. The contribution of common building materials to high indoor concentrations with a range of 30 Bq/m"3 is negligible low. Therefore building materials for radon mitigation should be judged by their tightness against diffusive radon and not by their radon exhalation rate. Also isolation materials for mitigation should be radon tight. The radon diffusion coefficient describes the physical processes in relatively homogeneous samples. The diffusion coefficient D and the diffusion length R are very exactly determined by a self engineered measuring method. The range of D reaches from D = (0.0005 to 2.35) . 10"-"6 m"2/s for building materials and from D = (0.07 to < 10"-"6) . 10"-"6 m"2/s for isolation materials. Applicable mitigation measures like increased ...

58

Pulse compression in a free electron laser amplifier  

International Nuclear Information System (INIS)

We have studied both theoretically and experimentally a new scheme of active pulse compression in a free electron laser (FEL) amplifier. The pulse compression scheme presented here is the following. A frequency-chirped pulse is injected into the FEL interaction region. Because of the high gain and narrow bandwidth of the FEL interaction, only the resonant frequency band of the pulse is actively amplified, resulting in a short pulse of high power coherent radiation at the output of the laser. For our experimental parameters (beam voltage #approx =# 150 kV, current #approx =# 5.0 A, wiggler period #approx =# 3.5 cm and gain #approx =# 10 dB), pulses of a few nanoseconds were generated at #approx =# 10 GHz after an interaction length of 2.30 m, in good agreement with theoretical expectations. For the same input pulses (width > 100 ns, frequency chirp #alpha#/2#pi# #approx =# 5 MHz/ns), the obtention of such compression ratios would require ...

59

Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration  

Energy Technology Data Exchange (ETDEWEB)

A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium ...

1995-12-31

60

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section including guidance on ...

2002-12-01

61

A Single-Shot Method for Measuring Femtosecond Bunch Length in Linac-Based Free-Electron Lasers  

International Nuclear Information System (INIS)

There is growing interest in the generation and characterization of femtosecond and subfemtosecond pulses from linac-based free-electron lasers (FELs). In this report, following the method of Ricci and Smith (Phys. Rev. ST Accel. Beams 3, 032801 (2000)), we investigate the measurement of the longitudinal bunch profile of an ultrashort electron bunch produced by these FELs. We show that this method can be applied in a straightforward manner at x-ray FEL facilities such as the Linac Coherent Light Source by slightly adjusting the second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final linac. We find that the linac wakefield strongly perturbs the measurement, and through analysis show that it can be compensated in a simple way. We demonstrate the effectiveness of this method and wakefield compensation through numerical simulations, including effects of coherent synchrotron radiation and longitudinal space charge. When used in ...

2010-08-26

62

Spectroscopic investigation of the charge dynamics of heavy ions penetrating solid and gaseous targets  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents the study of the slowing down process of fast heavy ions inside matter. In the framework of this research, the influence of the target density on the stopping process is investigated. Experiments on the interaction of {sup 48}Ca{sup 6+}-{sup 48}Ca{sup 10+} and {sup 26}Mg{sup 5+} ion beams with initial energies of 11.4 MeV/u and 5.9 MeV/u with solid and gaseous targets have been carried out. A novel diagnostic method, X-ray spectroscopy of K-shell projectile radiation, is used to determine the ion charge state in relation to its velocity during the penetration of fast heavy ions inside the stopping material. A spatially resolved analysis of the projectile and target radiation in solids is achieved for the first time. The application of low-density silica aerogels as stopping media provided a stretching of the ion stopping length by 20 - 100 times in comparison with solid quartz. The Doppler Effect ...

2007-01-15

63

Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the interinstitutional ...

2007-06-01

64

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

Energy Technology Data Exchange (ETDEWEB)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord ...

1993-05-01

65

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

International Nuclear Information System (INIS)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously calculated using a chord ...

1993-01-01

66

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

68
69

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

70

Comparison and Physical Interpretation of MCNP and TART Neutron and Gamma Monte Carlo Shielding Calculations for a Heavy-Ion ICF System  

Energy Technology Data Exchange (ETDEWEB)

For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam lines, each focused by six magnets. A 3-D ...

2002-07-01

71

The use of restriction fragment length polymorphisms in paternity analysis.  

UK PubMed Central (United Kingdom)

This paper examines the utility of restriction fragment length polymorphisms (RFLPs) for paternity analysis. While, on the average, 99% of falsely accused males can be excluded with the standard battery...Full Text Available

1986-06-01

72

Temperature regulates limb length in homeotherms by directly modulating cartilage growth  

UK PubMed Central (United Kingdom)

Allen's Rule documents a century-old biological observation that strong positive correlations exist among latitude, ambient temperature, and limb length in mammals. Although genetic selection for thermoregulatory...Full Text Available

2008-12-09

73

Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with regularly spaced helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with full-length helical screw element of different twist ratio, and helical screw inserts with spacer length 100, 200, 300 and 400mm have been studied with uniform heat flux under laminar flow condition. The experimental data obtained are verified with those obtained from plain tube published data. The effect of spacer length on heat transfer augmentation and friction factor, and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The decrease in Nusselt number for the helical twist with spacer length is within 10% for each subsequent 100mm increase in spacer length. The decrease in friction factor is nearly two times lower than the full length helical twist at low Reynolds number, and four times lower ...

2007-02-15

74

Empirically derived predicators of natural gas flame lengths in circular tubes  

Energy Technology Data Exchange (ETDEWEB)

Flame lengths inside circular tubes, using an (in-shot) atmospheric burner design commonly found in gas-fired residential furnaces were visually observed for natural gas and air under various operating conditions. The flame length data were reduced into dimensionless flame lengths, which were shown to be linearly proportional to the Peclet number of the fuel and air mixture. The dimensionless flame length dependence reported does not scale according to the classical flame models: pre-mixed (laminar) flame or diffusion flame. Instead, the flame length dependence was found to scale with the fuel burn speed, gas/mixture properties (evaluated at the adiabatic flame temperature), and flow parameters. Currently, this is the only flame length study available for the standard atmospheric burner designs commonly used in residential heating products. The results and data ...

2000-07-01

75

Cumulative Inflammatory Load Is Associated with Short Leukocyte Telomere Length in the Health, Aging and Body Composition Study  

UK PubMed Central (United Kingdom)

BackgroundLeukocyte telomere length (LTL) is an emerging marker of biological age. Chronic inflammatory activity is commonly proposed as a promoter of ...Full Text Available

76

Service-Adaptive Multi-Type Repairman Problems  

Science.gov (United States)

... If the terminal classes were to be information sources ... current credibility of inputs by classes of terminals; the most ... the stochastic queue lengths. ...

1991-03-01

77

Lossless Coding with Generalised Criteria  

CERN Document Server

This paper presents prefix codes which minimize various criteria constructed as a convex combination of maximum codeword length and average codeword length or maximum redundancy and average redundancy, including a convex combination of the average of an exponential function of the codeword length and the average redundancy. This framework encompasses as a special case several criteria previously investigated in the literature, while relations to universal coding is discussed. The coding algorithm derived is parametric resulting in re-adjusting the initial source probabilities via a weighted probability vector according to a merging rule. The level of desirable merging has implication in applications where the maximum codeword length is bounded.

2011-01-01

78

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

79

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

81

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

83

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

84

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

85

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

86

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

87

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

88

Pinned fluxons in a Josephson junction with a finite-length inhomogeneity  

CERN Document Server

We consider a Josephson junction system installed with a finite length inhomogeneity, either of microresistor or of microresonator type. The system can be modelled by a sine-Gordon equation with a piecewise-constant function to represent the varying Josephson tunneling critical current. The existence of pinned fluxons depends on the length of the inhomogeneity, the variation in the Josephson tunneling critical current and the applied bias current. We establish that a system may either not be able to sustain a pinned fluxon, or - for instance by varying the length of the inhomogeneity - may exhibit various different types of pinned fluxons. Our stability analysis shows that changes of stability can only occur at critical points of the length of the inhomogeneity as a function of the (Hamiltonian) energy density inside the inhomogeneity - a relation we determine explicitly. In combination with ...

2011-01-01

89

Pineal and photoperiodic influences on fat deposition, pelage, and testicular activity in male meadow voles.  

Science.gov (United States)

Pinealectomy completely prevented gonadal regression as well as reduction in body weight and white adipose tissue content of the gonadal and retroperitoneal fat deposits in male meadow voles transferred from long to short day lengths. Pineal influences on pelage characteristics depended on which parameter was assessed. For instance, the increase in guard hair length observed in short-day control voles was blocked by pinealectomy; however, a similar increase in underhair length was unaffected by removal of the pineal gland. Photoperiod-dependent changes in fat deposition, testicular activity, and guard hair length presumably rely on altered pineal secretory activity to transduce the effects of day length on the neuroendocrine axis; however, mechanisms independent of pineal activity may be capable of mediating photoperiodic control of underhair growth. PMID:2979644

1988-01-01

90

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

91

Thermal Modeling and Performance Analysis of Interim Dry Storage and Geologic Disposal Facilities for Spent Nuclear Fuel  

Science.gov (United States)

Thermal models are constructed and analyses are performed of aluminum-based spent nuclear fuel (Al-SNF) in interim dry storage and geologic disposal configurations. Two models are developed, referred to as the interim storage model and the codisposal waste package (WP) model. Time-dependent source terms of Al-SNF forms and the defense high-level waste (DHLW) canisters are also developed for thermal performance analysis of the geologic codisposal WP.The interim storage model is a three-dimensional conduction-convection conjugate model to investigate the natural convection cooling of a sealed dry storage canister with vertical orientation in a dry storage vault. The analysis is made for various decay heat sources (equivalent to 25 to 35 kW/m{sup 3}) using various boundary conditions around the canister wall and with backfilled nitrogen or helium gas. Based on the data obtained from the Savannah River Site experimental work and available from the literature, an improved dimensionless ...

2000-07-15

92

Single-pass high-gain free electron laser electron beam diagnostics  

International Nuclear Information System (INIS)

Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the photocathode RF gun injection system. Characterization of short electron bunch (#approx#100 fs) produced by ...

2000-11-27

93

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact ...

2010-02-05

94

Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex ...

1990-01-01

95

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

96

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

98

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

99

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

100

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

101

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

102

Four-inch pipe whip test under BWR LOCA conditions effect of overhang length  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The deformation of the test pipe and restraints becomes large with increasing overhang length. It is clarified that ...

1983-03-01

103

Transfer of semantics from argumentation frameworks to logic programming A preliminary report  

CERN Document Server

There are various interesting semantics' (extensions) designed for argumentation frameworks. They enable to assign a meaning, e.g., to odd-length cycles. Our main motivation is to transfer semantics' proposed by Baroni, Giacomin and Guida for argumetation frameworks with odd-length cycles to logic programs with odd-length cycles through default negation. The developed construction is even stronger. For a given logic program an argumentation framework is defined. The construction enables to transfer each semantics of the resulting argumentation framework to a semantics of the given logic program. Weak points of the construction are discussed and some future continuations of this approach are outlined.

2011-01-01

104

Simulation of DNA electrophoresis through microstructures  

British Library Electronic Table of Contents (United Kingdom)

The dependence of the mobility of DNA molecules through an hexagonal array of micropillars on their length and the applied electric field was investigated and it was found that mobility is a nonmonotonic function of their length. Results also revealed that the size dependence of the DNA mobility depends on the applied electric field and there is a crossover around E 25 V/cm for the mobility of l-DNA and T4-DNA. These observations are explained in terms of the diffusion process inside the structure affected by the solvent and are modeled using the Langevin and its corresponding Fokker-Planck equations. The phenomenon is generalized under three regimes in a phase diagram relating the electric field and the DNA lengths. The model and the associated phase diagram described here provide an expl...

2007-01-01

105

Measurement of Turbulence Decorrelation during Transport Barrier Evolution in a High Temperature Fusion Plasma  

Energy Technology Data Exchange (ETDEWEB)

A low power polychromatic beam of microwaves is used to diagnose the behavior of turbulent fluctuations in the core of the JT-60U tokamak during the evolution of the internal transport barrier. A continuous reduction in the size of turbulent structures is observed concomitant with the reduction of the density scale length during the evolution of the internal transport barrier. The density correlation length decreases to the order of the ion gyroradius, in contrast to the much longer scale lengths observed earlier in the discharge, while the density fluctuation level remain similar to the level before transport barrier formation.

2005-03-29

106

Full-length fuel rod behavior under severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

This document presents an assessment of the severe accident phenomena observed from four Full-Length High-Temperature (FLHT) tests that were performed by the Pacific Northwest Laboratory (PNL) in the National Research Universal (NRU) reactor at Chalk River, Ontario, Canada. These tests were conducted for the US Nuclear Regulatory Commission (NRC) as part of the Severe Accident Research Program. The objectives of the test were to simulate conditions and provide information on the behavior of full-length fuel rods during hypothetical, small-break, loss-of-coolant severe accidents, in commercial light water reactors.

1992-12-01

107

Experimental investigation of the length of a free diffusion jet of fuel gases diluted with inert gases  

Science.gov (United States)

Experimental investigation of the length of single burning jets of methane and hydrogen previously diluted with an inert gas (nitrogen or helium) was carried out. Efflux of fuel gases into the atmosphere occurred through cylindrical extension pieces 4 and 8 mm in diameter. The Reynolds numbers at the cut of a piece varied in the range from 400 to 12,000. A clearly defined dependence of the jet length on the quality of the added inert gas is obtained. The correlation of experimental data made it possible to recommend formulas for engineering calculations of free laminar and turbulent jets.

2010-05-01

108

Evaluation of optimum sheath electric field for selective production of metallic carbon nanotubes  

International Nuclear Information System (INIS)

We estimate the optimum electric field at the sheath edge and the minimum interval among the nanotubes to promote the growth of armchair-type nanotubes (metallic character) as a function of the tube length. On the basis of the electric charge distribution in a nanotube and the optimum electric filed E*_1 at the tip of a nanotube evaluated using the Hueckel-Poisson method, we calculate the structure of the electric field lines outside a nanotube in the sheath region. As the tube length increases, the E*_1 decreases. To maintain the chemical activity at the tip, the sheath electric field must be decreased. We show the decreasing rate of the sheath field to the tube length.

2006-03-21

109

A Insulating Design of SF{sub 6} GAS Sealing end of Condenser Cone Type Used for 345 kV OF Cable  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we describes the research in condenser cone of SF{sub 6} gas sealing end for 345 kV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory and FEM. As a results, we have been designed the condenser cone and the inner insulation part of SF{sub 6} sealing end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone. (author). 4 refs., 3 figs., 3 tabs.

1994-07-01

111

Optical Diffraction Studies of Muscle Fibers  

UK PubMed Central (United Kingdom)

A new technique to monitor light diffraction patterns electrically is applied to frog semitendinosus muscle fibers at various levels of stretch. The intensity of the diffraction lines, sarcomere length...Full Text Available

1973-09-01

112

OBSERVATIONS ON THE VARIATIONS IN SIZE OF THE A REGION OF ARTHROPOD MUSCLE  

UK PubMed Central (United Kingdom)

The muscles of three different arthropods, a mite, a fly, and an ostracod, show variations in the length of the A region within a given individual. There is no indication that the observed differences...Full Text Available

1963-11-01

113

Modeling the AIM-9 Sidewinder Repair Line through Discrete ...  

Science.gov (United States)

... of electronic systems (satellite terminals, radio and ... helps organizations investigate the stochastic nature of ... cycle time, maximum queue lengths, and ...

2009-06-01

114

EHF Satellite Communications-on-the-Move Blockage ...  

Science.gov (United States)

... Wheeled Vehicle) equipped with a MILSTAR terminal was driven ... textbooks including Ronald W. Wolff, Stochastic Modeling and The ... Queue Length ...

2004-11-02

115

Development of a Suite of Luciferase Gene Probes for the ...  

Science.gov (United States)

... between 2 strains is acquired by adding the lengths of the connecting branches, using the scale which depicts 1 amino acid substitution per 10 ...

2011-05-15

116

Determination of critical length for pipe whip design  

Energy Technology Data Exchange (ETDEWEB)

Design of pipe whip restraints requires a knowledge of the maximum allowable unsupported pipe length. This paper presents a numerical method for calculating this critical length of the pipe. Salient features of the method are: (1) as a flow rounds an elbow, it exerts a transverse kick and an axial thrust to the pipe, both the axial thrust and the bending moment are considered; (2) the jet force is applied in an abrupt manner, the dynamic amplification factor (DAF) is determined from the load-deflection (H-{Delta}) curve of the pipe, by taking into consideration large strain, large deformation and the nonlinear stress-strain relationship of the piping material; (3) the ultimate capacity of the pipe under the combined action of an axial force and a bending moment is governed by an interaction formula. The maximum unsupported pipe length is calculated from this formula. Only the formulas and derivation are presented. Numerical ...

1995-11-01

117

CALS-HSC Data Element Dictionary  

Science.gov (United States)

... HAZARDOUS CODE IS REQUIRED BY MIL-STD-2073-1. Structure/Length: A01 Item/Code Assigned: N-NONHAZARDOUS ITEM Y-REGULATED ...

1992-10-01

118

An Optical Fiber Infrasound Sensor  

Science.gov (United States)

... We use a compliant, sealed tube helically wrapped with an optical fiber. ... 2.5 cm diameter compliant, sealed tube 10 m < length < 120 m ...

2000-09-01

119

AFM Imaging of SWI/SNF action: mapping the nucleosome remodeling and sliding  

CERN Document Server

We propose a combined experimental (Atomic Force Microscopy) and theoretical study of the structural and dynamical properties of nucleosomes. In contrast to biochemical approaches, this method allows to determine simultaneously the DNA complexed length distribution and nucleosome position in various contexts. First, we show that differences in the nucleo-proteic structure observed between conventional H2A and H2A.Bbd variant nucleosomes induce quantitative changes in the in the length distribution of DNA complexed with histones. Then, the sliding action of remodeling complex SWI/SNF is characterized through the evolution of the nucleosome position and wrapped DNA length mapping. Using a linear energetic model for the distribution of DNA complexed length, we extract the net wrapping energy of DNA onto the histone octamer, and compare it to previous studies.

2007-01-01

122

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

130

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

134

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...

135

Radiation Therapy in Treating Patients With Prostate Cancer  

Science.gov (United States)

Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility

2011-09-13

137

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

139

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

140

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

141

Survey of Radiation Protection Education and Training in Finland in 2003  

Energy Technology Data Exchange (ETDEWEB)

The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...

2004-07-01

142

Void growth and softening of a single crystal with strain gradient effects  

Energy Technology Data Exchange (ETDEWEB)

The strain gradient crystal plasticity theory is applied to study the deformation of planar single crystal with a void under a nominally uniaxial tension. The crystal theory assumes elevated strain hardening due to slip gradients and has a constitutive length scale. The effects of the void size with respect to the constitutive length scale on the single crystal deformation are investigated.

1997-02-06

143

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

144

Plasmids for the cloning and expression of full-length double-stranded cDNAs under control of the SV40 early or late gene promoter.  

UK PubMed Central (United Kingdom)

Okayama and Berg (1) have recently described a technique for the high efficiency cloning of full-length dscDNAs. We have constructed eukaryotic expression vectors compatible both with this technique...Full Text Available

1983-10-25

145

Interactions between heavy mesons and Goldstone bosons from chiral dynamics  

Energy Technology Data Exchange (ETDEWEB)

We calculate the S-wave scattering lengths for charmed mesons scattering off Goldstone bosons and explore their quark mass dependence using the chiral perturbation theory up to next-to-leading order as well as a unitarized version of it. The quark mass dependence of all scattering lengths determined in a recent lattice calculation can be reproduced by the unitarized version. We also discuss signals of possible bound states in these observables. (orig.)

2009-05-15

146

Genetic Control of Capsid Length in Bacteriophage T4 I. Isolation and Preliminary Description of Four New Mutants  

UK PubMed Central (United Kingdom)

Four new mutants are described whose phenotypic expression affects the length of the head of bacteriophage T4D. All mutants produce some phenotypically normal phage particles. Mutant pt21-34...Full Text Available

1973-08-01

147

A volume formula for hyperbolic tetrahedra in terms of edge lengths  

CERN Document Server

We give a closed formula for volumes of generic hyperbolic tetrahedra in terms of edge lengths. The cue of our formula is by the volume conjecture for the Turaev-Viro invariant of closed 3-manifolds, which is defined from the quantum 6j-symbols. This formula contains the dilogarithm functions, and we specify the adequate branch to get the actual value of the volumes.

2004-01-01

148

A simple and continuous on-state current model of polysilicon thin-film transistors for circuit simulation  

Energy Technology Data Exchange (ETDEWEB)

A simple and continuous model for the on-state current of polysilicon thin-film transistors, suitable for implementation in circuit simulators, is presented. The model includes the potential barrier at the grain boundaries, the channel length modulation and the excess current due to impact ionization. Comparison between measured output characteristics and the model shows excellent agreement over wide range of bias voltages and for devices with different gate lengths.

2005-01-01

149

CT-Expo - a novel program for dose evaluation in CT; CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT  

Energy Technology Data Exchange (ETDEWEB)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section including guidance on ...

2002-12-01

150

Liposome encapsulation of lipophilic N-alkyl-propanediamine platinum complexes: impact on their cytotoxic activity and influence of the carbon chain length  

Energy Technology Data Exchange (ETDEWEB)

Antitumor platinum(II) complexes derived from N-alkyl-propanediamine differing in the length of their carbon chain (C8, C10, C12 and C14) were incorporated in liposomes and the cytotoxic activity of these formulations was evaluated against tumor (A{sub 549}, MDA-MB-231, B16-F1 and B16-F10) and non-tumor (BHK-21 and CHO) cell lines. Stable and monodisperse liposome suspensions incorporating the platinum complexes were obtained from the lipid composition consisting of distearoyl-sn-glycero-3-phosphocholine, cholesterol and 1,2-distearoyl-sn-glycero- 3-phosphoethanolamine-N-(methoxy(polyethylene glycol)-2000) at 5:3:0.3 molar ratio. The entrapment efficiency (EE%) of the platinum complexes in liposomes increased with the carbon chain length. EE% was higher than 80% in C12- and C14-derivatives. The effect of liposome encapsulation on the cytotoxic activity of the complexes was found to depend on the carbon chain length. These ...

2010-07-01

151

Development of the heated length to diameter correction factor on critical heat flux using the artificial neural networks  

Energy Technology Data Exchange (ETDEWEB)

With using artificial neural networks (ANNs), an analytical study related to the heated length effect on critical heat flux (CHF) has been carried out to make an improvement of the CHF prediction accuracy based on local condition correlations or table. It has been carried out to suggest a feasible criterion of the threshold length-to-diameter (L/D) value in which heated length could affect CHF. And within the criterion, a L/D correction factor has been developed through conventional regression. In order to validate the developed L/D correction factor, CHF experiments for various heated lengths have been carried out under low and intermediate pressure conditions. The developed threshold L/D correlation provides a new feasible criterion of L/D threshold value. The developed correction factor gives a reasonable accuracy for the original database, showing the error of -2.18% for average and 27.75% for RMS, ...

1998-12-31

152

Attenuation data of point isotropic neutron sources up to 400MeV in water, ordinary concrete and iron  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive attenuation data of dose equivalent for point isotropic monoenergetic neutron sources up to 400MeV in infinite shields of water, ordinary concrete and iron has been calculated using the ANISN-JR code and a neutron-photon multigroup macroscopic cross section HIL086R. The attenuation factors were fitted to a 4th order polynomial exponent formula, making possible to use easily for point kernel codes. Additional data in finite shielding geometry was also calculated to correct the effect due to infinite medium, giving the maximum correction of 0.23 in the region for more 400 cm distance from neutron source of 400 MeV in iron shield. Effective attenuation length for monoenergetic neutrons have been studied in detail. Subsequently, it was shown that the attenuation length was strongly dependent upon the penetration length and the Moyer`s formula using a single attenuation length brought large ...

1994-08-01

153

The benefits of low level radiation  

Energy Technology Data Exchange (ETDEWEB)

The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).

1997-06-01

154

Stimulated radiation of high - current relativistic electron beams  

International Nuclear Information System (INIS)

The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.

1987-01-01

155

Radiation protection. A guide for scientists and physicians  

International Nuclear Information System (INIS)

This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...

156

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...

2011-01-01

157

Biological effects of electromagnetic radiation in the microwave range  

Energy Technology Data Exchange (ETDEWEB)

The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...

1980-01-01

158

[The indicators of biological age and accelerated aging in liquidators of the consequences of radiation emergency].  

Science.gov (United States)

The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627

2011-01-01

159

The THz Radiation from Undulator  

Science.gov (United States)

The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.

2010-02-03

160

Study of emission of Cerenkov radiation by tachyons  

Energy Technology Data Exchange (ETDEWEB)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.

1983-01-01

161

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

162

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

163

Potential Hazards from Neutrino Radiation at Muon Colliders  

CERN Document Server

High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.

1999-01-01

164

Model of quantum noise of shadow radiation images  

International Nuclear Information System (INIS)

Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems

165

Coherent oscillator radiation  

International Nuclear Information System (INIS)

Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.

1982-04-01

166

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved x-ray-emitting zones for all the anodes were captured by a pinhole-based x-ray imaging camera and the images were ...

2006-01-01

167

Resonantlike phenomenon in short-pulse free-electron-laser oscillators with modulated desynchronism  

International Nuclear Information System (INIS)

Recently a new method of controlling the pulse length of a short-pulse free-electron laser (FEL) has been developed. By modulating the synchronism between the optical and electron pulses in the FEL cavity, it was found that the output power and the micropulse length of the FEL beam oscillates at the modulation frequency. In this paper, we study theoretically the behavior of the micropulse length, both in the high loss (steady state) regime and the low loss (limit cycle) regime, when a modulated desynchronism is applied. In order to do this, we analyze the dynamics of a short-pulse FEL oscillator. The modulation frequency value plays an important role in the dynamics. We find that there is a resonantlike phenomenon between the externally applied desynchronism modulation and the limit cycle oscillation without modulation of a free-electron laser.

2002-01-01

168

Rapid risk assessment using probability of fracture nomographs  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT Traditional risk-based design process involves designing the structure based on risk estimates obtained during several iterations of an optimization routine. This approach is computationally expensive for large-scale aircraft structural systems. Therefore, this paper introduces the concept of risk-based design plots that can be used for both structural sizing and risk assessment for fracture strength when maximum allowable crack length is available. In situations when crack length is defined as a probability distribution the presented approach can only be applied for various percentiles of crack lengths. These plots are obtained using normalized probability density models of load and material properties and are applicable for any arbitrary load and strength values. Risk-based desi...

2009-01-01

169

Molecular analysis of polymerase gamma gene and mitochondrial polymorphism in fertile and subfertile men  

British Library Electronic Table of Contents (United Kingdom)

Summary CAG trinucleotide repeat length in the nuclear polymerase gamma gene (POLg) has been shown to be associated with men with reduced fertility. The present study investigated the frequency of CAG repeat length genotypes and three exonuclease motifs of the POLg in relation to the frequency of mitochondrial nucleotide substitutions. DNA from semen samples of 93 normozoospermic men and 192 non-normozoospermic men was isolated and the specific regions of the genes were amplified by polymerase chain reactions (PCR) and sequenced to identify mutations. The genotypic frequencies of pooled POLg CAG repeat lengths, =10/!=10 heterozygotes and !=10/!=10 homozygotes, were significantly different between normozoospermic and non-normozoospermic men (p p POLg genotype. Of the 17 men with non-synonym...

2006-01-01

170

Modelling and design of smoothing reactances. Application to air gap length calculation  

Energy Technology Data Exchange (ETDEWEB)

A new method for analysis and design of smoothing reactances utilising two-dimensional planar models is presented in this paper. Inductance and magnetic flux density are calculated, and their results compared with those measured experimentally. The results obtained are good if compared with those measured once the machine have been built. Moreover, the method herein developed is applied to the calculation of air gap lengths in terms of the desired current and inductance. The kind of reactances studied presents windings in both limbs and air gaps in the four corners (joint of limbs and yokes). The main contribution of this paper is the presentation of a method of industrial application, to be easily developed, with a very important reduction in the time of machine calculation (due to the decrease in the number of nodes and elements compared with the three-dimensional model) for the determination of the air gap length in smoothing reactances. ...

2000-08-01

171

Large scintillation cells for high sensitivity radon concentration measurements  

Energy Technology Data Exchange (ETDEWEB)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alpha source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length ...

1983-07-01

172

Large scintillation cells for high sensitivity radon concentration measurements  

International Nuclear Information System (INIS)

Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alphy source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length ...

173

Influence of physico-mechanical properties of rocks and of operating technology on the selection of bench belt conveyors for lignite surface mines  

Energy Technology Data Exchange (ETDEWEB)

This paper considers the physical and mechanical properties of rocks (volumetric density, angle of repose, lump size, abrasive strength, etc.), and their influence on choice of belt conveyors for overburden haulage. Technological parameters (length and output of benches, coefficient of utilization and reliability of equipment, investment cost, etc.) are also considered. Data are given on the capacity and length of conveyors widely used in coal surface mining (width up to 3,000 mm, speed up to 6 m/s and capacity 24,000-35,000 t/h at lengths of 1,400-3,000 m). (12 refs.) (In Serbo-Croat)

1981-01-01

174

High channel density wavelength division multiplexer with defined diffracting means positioning  

Energy Technology Data Exchange (ETDEWEB)

A wavelength division multiplexer/demultiplexer having optical path lengths between a fiber array and a Fourier transform lens, and between a dispersion grating and the lens equal to the focal length of the lens. The optical path lengths reduce losses due to angular acceptance mismatch in the multiplexer. Close orientation of the fiber array about the optical axis and the use of a holographic dispersion grating reduces other losses in the system. Multi-exposure holographic dispersion gratings enable the multiplexer/demultiplexer for extremely broad-band simultaneous transmission and reflection operation. Individual Bragg plane sets recorded in the grating are dedicated to and operate efficiently on discrete wavelength ranges.

1990-01-01

175

Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe  

International Nuclear Information System (INIS)

To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).

1994-05-01

176

First trimester measurements of nasal bone length using three-dimensional ultrasound  

British Library Electronic Table of Contents (United Kingdom)

Objectives To investigate the feasibility and reproducibility of measurements of nasal bone length using a three-dimensional (3D) ultrasound in the first trimester. Methods In a prospective study, 118 consecutive pregnant women attending for Down syndrome screening at 11-13 + 6 weeks were recruited. They had successful fetal nasal bone measurement by two-dimensional (2D) ultrasound by four operators. Three-dimensional volumes were recorded in the mid-sagittal plane of fetal profile by the fifth operator and examined using multiplanar techniques. Another independent investigator randomly compared his measurements with one of the four operators. Results In the subsequent 3D examination, the nasal bone length could be examined in 94 cases (79.7%). The mean difference between the 2D and 3D mea...

2009-01-01

177

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

178

Asymptotic Safety, Asymptotic Darkness, and the hoop conjecture in the extreme UV  

CERN Document Server

Assuming the hoop conjecture in classical general relativity and quantum mechanics, any observer who attempts to perform an experiment in an arbitrarily small region will be stymied by the formation of a black hole within the spatial domain of the experiment. This behavior is often invoked in arguments for a fundamental minimum length. Extending a proof of the hoop conjecture for spherical symmetry to include higher curvature terms we investigate this minimum length argument when the gravitational couplings run with energy in the manner predicted by asymptotically safe gravity. We show that argument for the mandatory formation of a black hole within the domain of an experiment fails. Neither is there a proof that a black hole doesn't form. Instead, whether or not an observer can perform measurements in arbitrarily small regions depends on the specific numerical values of the couplings near the UV fixed point. We further argue that when an ...

2010-01-01

179

Application of high velocity impact welding at varied different length scales  

British Library Electronic Table of Contents (United Kingdom)

Three complementary impact welding technologies are described in this paper. They are explosive welding, magnetic pulse welding, and laser impact welding, which have been used to provide metallurgical bonds between both similar and dissimilar metal pairs. They share the physical principle that general impact-driven welding can be carried out by oblique impact but are used at different length scales from meters to sub-millimeter. The different length scales require different kinds of systems to drive the process, and the scales themselves can give different weld morphologies. Metallographic analysis on cross-sections shows a wavy interface morphology which is likely the result of an instability associated with jetting, which scours the surfaces clean during impact. The normalized period and...

2011-01-01

180

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

182

Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries  

UK PubMed Central (United Kingdom)

Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available

2005-07-09

183

Radiation therapy alone versus radiation therapy and chemotherapy in the management of Hodgkin's disease.  

UK PubMed Central (United Kingdom)

Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available

1990-02-01

184

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

185

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

186

Lagranzheva dinamika kollektivnykh vzaimodejstvij v potokakh diskretnykh izluchatelej. (Lagrange dynamics of collective interactions in flows of discrete radiators).  

Science.gov (United States)

Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...

1989-01-01

187

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

188

Are natural radioactive materials dangerous  

International Nuclear Information System (INIS)

The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).

1974-09-23

189

A radiator of electromagnetic waves with a combined shape of generatrices  

British Library Electronic Table of Contents (United Kingdom)

The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.

2008-01-01

190

Using ICCD as a fast optical switch to measure harmonic super-radiation from an optical klystron in a storage ring  

International Nuclear Information System (INIS)

An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate

2001-07-01

191

The medical exposures to ionizing radiations, it is a world priority in radiation protection  

International Nuclear Information System (INIS)

The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)

192

x - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation ...

193

VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...  

Science.gov (United States)

Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...

194

Treatment of persons exposed in radiation accidents or nuclear explosions. Omhaendertagande av skadade vid radiakolyckor och kaernvapenexplosioner  

Energy Technology Data Exchange (ETDEWEB)

The report gives general principles of treatment and care of casualties caused by radiation accidents or nuclear explosions.

1991-01-01

195

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

197

Tachyon Cerenkov radiation  

Energy Technology Data Exchange (ETDEWEB)

By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.

1985-09-01

198

Solar Cell Radiation Response near the Interface of Different ...  

Science.gov (United States)

... Solar Cell Radiation Respinnse Near the Interface o~f fliffprerv- ... 5 4. CALCUTl-ATED SOLAR CELL RLSPONSE FOR VARIOUS BASE MATERIALS ...

1971-11-01

199

Relationship of Optical Coating on Thermal Radiation ...  

Science.gov (United States)

drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...

200

References | Radiation Protection | US EPA  

Wastenet

...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...

201
202

Radiation deamination of tetracycline. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.

1980-01-01

203

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compounds in EBR-II and FFTF  

Energy Technology Data Exchange (ETDEWEB)

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF

1999-05-01

204

Onclas U9800 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

the probability of its spontaneous radiation de-excitation increases. ... consider spontaneous radiation transitions. We will examine the ...

205

Numerical analysis of methane-air combustion considering radiation effect  

Energy Technology Data Exchange (ETDEWEB)

Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to ...

2008-12-15

206

Numerical analysis of methane-air combustion considering radiation effect  

International Nuclear Information System (INIS)

Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the ...

2008-12-01

207

Multifunctional, Boron-Foam Based Radiation Shielding  

Science.gov (United States)

PROPOSAL NUMBER: 04 B3.09-7744. SUBTOPIC TITLE: Radiation Shielding to Protect Humans. PROPOSAL TITLE: Multifunctional, Boron-Foam Based ...

208

Mathematical Analysis of Three Free-Electron-Laser Issues  

Science.gov (United States)

... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...

1990-09-30

209

Equipment hardening and hardness assurance  

International Nuclear Information System (INIS)

The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...

210

Enhanced coherent undulator radiation from bunched electron beams  

International Nuclear Information System (INIS)

When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...

1995-09-28

212

ESR study in radiation damage in pyrimidines. 3-year comprehensive progress report  

International Nuclear Information System (INIS)

General mechanisms of radiation damage to biomolecules was studied by using substituted pyrimidines, particularly barbituric acid derivatives.

213

Differences in synchrotron radiation induced gas desorption from stainless steel and aluminium alloy  

CERN Document Server

Differences in synchrotron radiation induced gas desorption from stainless steel and aluminium alloy

1990-01-01

214

Combined Radiation and Thermal Injury after Nuclear Attack  

Science.gov (United States)

... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...

2011-05-13

215

Chinese Journal of Lasers (Selected Articles)  

Science.gov (United States)

... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...

1991-12-10

216

An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors  

UK PubMed Central (United Kingdom)

PurposeTo evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors.Methods...Full Text Available

2008-04-01

217

Viruses with More Than 1,000 Genes: Mamavirus, a New Acanthamoeba polyphaga mimivirus Strain, and Reannotation of Mimivirus Genes  

UK PubMed Central (United Kingdom)

The genome sequence of the Mamavirus, a new Acanthamoeba polyphaga mimivirus strain, is reported. With 1,191,693 nt in length and 1,023 predicted protein-coding genes, the Mamavirus...Full Text Available

2011-01-01

218

Universal Cervical Length Screening and Treatment with Vaginal Progesterone to Prevent Preterm Birth: A Decision and Economic Analysis  

UK PubMed Central (United Kingdom)

ObjectiveTo estimate which strategy is the most cost-effective for prevention of preterm birth and associated morbidity.Study DesignFull Text Available

2010-06-01

219

US Air Force Aircraft in Southeast Asia Tested by the Air Force ...  

Science.gov (United States)

... feet in length, and 26 feet 2 inches high. The AC-119G and AC-119K, are powered with two General Electric J85-17 jet engines pod-mounted ...

1970-03-01

220

The inhomogeneous structure of water at ambient conditions  

UK PubMed Central (United Kingdom)

Small-angle X-ray scattering (SAXS) is used to demonstrate the presence of density fluctuations in ambient water on a physical length-scale of ≈1 nm; this is retained with decreasing temperature...Full Text Available

2009-09-08

221

The DP-2 addresses the need for vertical operating aircraft with ...  

Science.gov (United States)

C-130J payload reduced to make radius. ** Current C-17A uses 3000 ft field, C- 17A+ estimated cost of $378M per plane with. 2000 ft field length, ...

222

TABLE A: SPTR SITE SELECTION ANALYSIS LOCATION V ... - NASA  

Science.gov (United States)

OPERATE AT SOUTH POLE WINTER AMBIENTS, GIVEN THE PROJECT'S BUDGET AND TIME LINES . ... 17 MAXIMUM ELECTRICAL LENGHT CONSTRAINED BY Ku-BAND AT 50 FT. ... A MAXIMUM LENGTH OF 50 FEET HAS BEEN SPECIFIED BY THE SYSTEM LINK CALCULATIONS TO ...

223

Structural Characterization and Expression Analysis of the SERK/SERL Gene Family in Rice (Oryza sativa)  

UK PubMed Central (United Kingdom)

Somatic embryogenesis (SE) is the developmental restructuring of somatic cells towards the embryogenic pathway and forms the basis of cellular totipotency in angiosperms. With the availability of full-length...Full Text Available

2009-01-01

224

Serotonin Transporter Binding and Genotype in the Nonhuman Primate Brain using [C-11]DASB PET  

UK PubMed Central (United Kingdom)

The length polymorphism of the serotonin (5-HT) transporter gene promoter region has been implicated in altered 5-HT function and, in turn, neuropsychiatric illnesses, such as anxiety and depression....Full Text Available

2009-10-01

225

Seizures increase cell proliferation in the dentate gyrus by shortening progenitor cell cycle length  

UK PubMed Central (United Kingdom)

PurposeA prolonged seizure, status epileptics (SE), is a potent stimulus for increased neurogenesis in the dentate gyrus of the hippocampus. Molecular mechanisms...Full Text Available

2009-11-18

226

Safety and efficacy of botox injection in alleviating post-operative pain and improving quality of life in lower extremity limb lengthening and deformity correction  

UK PubMed Central (United Kingdom)

BackgroundDistraction osteogenesis is the standard treatment for the management of lower limb length discrepancy of more than 3 cm and bone loss secondary to congenital anomalies,...Full Text Available

227

Ravenscraig coke ovens 1988 and onwards  

Energy Technology Data Exchange (ETDEWEB)

The coking plant is described with some details of coal supplies and coke quality. Engineering improvements to the by-product system and coke oven machines, major repair of two batteries, installation of a PLC-based monitoring and control system, and training of personnel are dealt with at greater length.

1989-01-01

228

Purification of functional baculovirus particles from silkworm larval hemolymph and their use as nanoparticles for the detection of human prorenin receptor (PRR) binding  

UK PubMed Central (United Kingdom)

BackgroundBaculovirus, which has a width of 40 nm and a length of 250-300 nm, can display functional peptides, receptors and antigens on its surface by their fusion with a baculovirus...Full Text Available

229

Phagocytic response of bovine polymorphonuclear leukocytes to different incubation conditions and following exposure to some effectors of phagocytosis and different anticoagulants in vitro.  

UK PubMed Central (United Kingdom)

The ability of bovine polymorphonuclear leukocytes (PMN) to phagocytose fluorescent beads in vitro was studied using flow cytometry. The effects of varying laboratory conditions (bead:PMN ratio, length...Full Text Available

2001-01-01

230

Pathogenicity of molecularly cloned bovine leukemia virus.  

UK PubMed Central (United Kingdom)

To delineate the mechanisms of bovine leukemia virus (BLV) pathogenesis, four full-length BLV clones, 1, 8, 9, and 13, derived from the transformed cell line FLK-BLV and a clone construct, pBLV913,...Full Text Available

1993-12-01

231

PDS_VERSION_ID = PDS3 /* FILE FORMAT AND LENGTH */ RECORD_TYPE ...  

Science.gov (United States)

KDZ@PEDEL@6RRD>ME0HBF?73 96:IE4K?8814# &=83J46:7A4;/??/D;69>B,F=9>E6L@8A82? ...

232

Optical Feshbach Resonances in Alkaline Earth Atoms  

Science.gov (United States)

Recent proposals have shown that a quantum degenerate gas of alkaline earth atoms can be used for a number of novel quantum computing and quantum simulation experiments. Strontium is a good candidate for such experiments because it can be controlled with high precision, as demonstrated in recent atomic clock experiments. Unfortunately, the small scattering length of strontium is not amenable to evaporative cooling techniques that are used to reach quantum degeneracy. Furthermore, increasing the scattering length of alkaline earths with a magnetic Feshbach resonance is not possible due to their spinless electronic ground state configuration. However, recent theoretical and experimental work suggests the possibility of changing scattering lengths in alkaline earths with laser light. Using this optical Feshbach resonance near strontium's narrow ^1S0->^3P1 intercombination transition might allow its scattering ...

2009-10-01

233

N69-15901 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

The beta titanium alloy, however, can be d_,_wn. _,plusor minus 0.010-inch_after the parts have been cold. Its availability in strip lengths and its good ...

234

Molecular characterization of a Chinese variant of the Flury-LEP strain  

UK PubMed Central (United Kingdom)

The entire genome of rabies virus vaccine strain Flury-LEP-C, a Chinese variant of the rabies virus vaccine strain Flury-LEP, was sequenced. The overall length of the genome of Flury-LEP-C strain was...Full Text Available

235

Molecular Variability of Pseudallescheria boydii, a Neurotropic Opportunist  

UK PubMed Central (United Kingdom)

The sequences of the internal transcribed spacer (ITS) ribosomal DNA (rDNA) domain data obtained by restriction fragment length polymorphism analysis with 18S rDNA and fingerprinting (M13) for clinical...Full Text Available

2000-09-01

236

Molecular Architecture of the Centriole Proteome: The Conserved WD40 Domain Protein POC1 Is Required for Centriole Duplication and Length Control  

UK PubMed Central (United Kingdom)

Centrioles are intriguing cylindrical organelles composed of triplet microtubules. Proteomic data suggest that a large number of proteins besides tubulin are necessary for the formation and maintenance...Full Text Available

2009-02-15

237

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Science.gov (United States)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil probe designs, ...

1992-08-01

238

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the performance of pancake coil probe designs, and ...

1992-08-01

239

Meiotic recombination in the beta globin gene cluster causing an error in prenatal diagnosis of beta thalassaemia.  

UK PubMed Central (United Kingdom)

In the course of a prenatal diagnosis for beta thalassaemia by linkage analysis of restriction fragment length polymorphisms, a homozygous beta thalassaemia fetus was misdiagnosed as beta thalassaemia...Full Text Available

1988-05-01

240

Mach 4 Performance of Hypersonic Inlet with Rectangular-to ...  

Science.gov (United States)

station in flowmeter used for mass flow calculation. Introduction. THE design .... length (as a result of a less conservative boundary-layer separation criterion), 2) slight ..... ical Flow, AGARD Conference Proceedings, No. 30, 1968. 5Kantrowitz ...

241

Journey Into Cyberspace (6-Part Video Series) - NASA CORE ...  

Science.gov (United States)

Nov 30, 2010 ... Journey Into Cyberspace (6-Part Video Series). Length/Year. 146 minutes/1993. Media. VHS. Item Number. 004.0-11V ...

242

Involvement of the Matrix and Nucleocapsid Domains of the Bovine Leukemia Virus Gag Polyprotein Precursor in Viral RNA Packaging  

UK PubMed Central (United Kingdom)

The RNA packaging process for retroviruses involves a recognition event of the genome-length viral RNA by the viral Gag polyprotein precursor (PrGag), an important step in particle morphogenesis. The...Full Text Available

2003-09-01

243

Insights into Cdc13 dependent telomere length regulation  

UK PubMed Central (United Kingdom)

Cdc13 is a single stranded telomere binding protein that specifically localizes to the telomere ends of budding yeasts and is essential for cell viability. It caps the ends of chromosomes thus preventing...Full Text Available

244

Increase in Internode Length of Phaseolus lunatus L. Caused by Inoculation with a Nitrate Reductase-deficient Strain of Rhizobium sp. 1  

UK PubMed Central (United Kingdom)

Dramatic differences in the height of lima beans (Phaseolus lunatus L.) treated with two different Rhizobium strains were studied. Lima beans were grown in Perlite...Full Text Available

1981-01-01

245

Identification of PITX1 as a TERT Suppressor Gene Located on Human Chromosome 5 ?  

UK PubMed Central (United Kingdom)

Telomerase, a ribonucleoprotein enzyme that maintains telomere length, is crucial for cellular immortalization and cancer progression. Telomerase activity is attributed primarily to the expression of...Full Text Available

2011-04-01

246

Hospital Admission Rates and Lengths of Treatment Among a ...  

Science.gov (United States)

Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...

2001-09-01

247

Genome-wide profiling of forum domains in Drosophila melanogaster  

UK PubMed Central (United Kingdom)

Forum domains are stretches of chromosomal DNA that are excised from eukaryotic chromosomes during their spontaneous non-random fragmentation. Most forum domains are 50–200 kb in length....Full Text Available

2011-05-01

248

Fluorescence amplified fragment length polymorphism for subtyping of genotypes of Acanthamoeba isolated from patients with keratitis  

UK PubMed Central (United Kingdom)

Background & objectives:Acanthamoeba keratitis (AK) is a painful and vision-threatening ocular infection. The differentiation of Acanthamoeba...Full Text Available

2011-01-01

249

Expression and purification of a functional human hepatitis B virus polymerase  

UK PubMed Central (United Kingdom)

AIM: To identify a method for efficient large-scale purification of functional hepatitis B virus polymerase (HBV-Pol) without addition of cellular factors.METHODS: Full-length HBV-Pol (843 amino...Full Text Available

2010-12-07

250

Epicuticular Wax Accumulation and Fatty Acid Elongation Activities Are Induced during Leaf Development of Leeks1  

UK PubMed Central (United Kingdom)

Epicuticular wax production was evaluated along the length of expanding leek (Allium porrum L.) leaves to gain insight into the regulation of wax production. Leaf segments from the...Full Text Available

1998-03-01

251

Effect on heat-transfer augmentation by channel width in a sinusoidal wave channel  

Energy Technology Data Exchange (ETDEWEB)

In the development of high performance heat transfer surface on a compact heat exchanger, it was clarified that how reattachment point heat transfer and fluid flow are affected by channel width, at the same time, an evaluation of heat transfer performance and an investigation of optimum channel width were carried out. The channel system used in the experiment is as follows; (1) blow-off type with rectangular section channel, (2) span length of 200 mm, (3) wave length (pitch) of 80 mm, and (4) channel length of 12.5 wave length. The channel Reynolds number was set at about 10/sup 4/ which is relatively higher than the current studies. The results of the experiment were summarized as follows. (1) The channel width H has relevance to the phase difference between the fluid flow in cone portion of main stream and wave shape, the flow patterns are divided roughly into three types. These boundaries exist at ...

1988-06-25

252

Effect of Length of Time before Incorporation on Survival of Pathogenic Bacteria Present in Livestock Wastes Applied to Agricultural Soil  

UK PubMed Central (United Kingdom)

In response to reports that the contamination of food can occur during the on-farm primary phase of food production, we report data that describes a possible cost-effective intervention measure. The...Full Text Available

2004-09-01

253

Duration of human singleton pregnancies in Ibadan, Nigeria.  

UK PubMed Central (United Kingdom)

Analysis of gestation length in an obstetric population of indigenous African women revealed a mean pregnancy duration of 274.8 days, which is similar to values recorded in women of African descent...Full Text Available

1997-09-01

254

Diagnostic Dilemma in an Unusual Case of Common Bile Duct Obstruction  

UK PubMed Central (United Kingdom)

Biliary obstructions are rarely caused by a foreign body and have received sparse attention. We present an unusual case with pruritis and abdominal pain caused by impacted full length surgical gauze...Full Text Available

2011-06-01

255

Development of a novel data mining tool to find cis-elements in rice gene promoter regions  

UK PubMed Central (United Kingdom)

BackgroundInformation on more than 35 000 full-length Oryza sativa cDNAs, together with associated microarray gene expression data collected under various treatment...Full Text Available

256

Deposition and retention of inhaled fibres: effects on incidence of lung cancer and mesothelioma.  

UK PubMed Central (United Kingdom)

A review of the literature on chronic inhalation studies in which rats were exposed to mineral fibres at known fibre number concentrations was undertaken to examine the specific roles of fibre length...Full Text Available

1994-12-01

257

DMSA scan nomograms for renal length and area: Related to patient age and to body weight, height or surface area  

International Nuclear Information System (INIS)

Aim: To create nomograms for renal size as measured from DMSA renal studies, and to test the nomograms for their ability to separate normal from abnormal kidneys. Method: Renal length was measured from posterior oblique views and renal area from posterior views. Results from 253 patients with bilateral normal kidneys were used to create nomograms for renal size relative to patient age, body height, weight or body surface area (BSA). The nomograms enclosed 95% of the normal kidneys, thus indicating the range for 95% confidence limits, and hence the specificity. Each nomogram was then tested against 46 hypertrophied kidneys and 46 damaged kidneys. Results: The results from nomograms of renal length and renal area, compared to age, body height, body weight and BSA are presented. For each nomogram, the range is presented as a fraction of the mean value, and the number of abnormal kidneys (hypertrophied or damaged) outside the normal range is ...

2002-09-01

258

Critical nucleus size for disease-related polyglutamine aggregation is repeat length dependent  

UK PubMed Central (United Kingdom)

Since polyglutamine (polyQ) aggregate formation has been implicated as playing an important role in expanded CAG repeat diseases, it is important to understand the biophysics underlying the...Full Text Available

2011-03-01

259

Circulating Matrix Metalloproteinases in Infective Endocarditis: A Possible Marker of the Embolic Risk  

UK PubMed Central (United Kingdom)

BackgroundEmbolic events (EE) in infective endocarditis (IE) are caused by fragmentation of vegetations or valvular tissue. Vegetation length is considered to be the most potent...Full Text Available

260

Association between length of storage of red blood cell units and outcome of critically ill children: a prospective observational study  

UK PubMed Central (United Kingdom)

IntroductionTransfusion is a common treatment in pediatric intensive care units (PICUs). Studies in adults suggest that prolonged storage of red blood cell units is associated with...Full Text Available

2010-01-01

261

A method for acetic processing of an electric, centrifugal well pump  

Energy Technology Data Exchange (ETDEWEB)

In order to reduce the length and to increase the effectiveness of processing, the proposed method for acetic processing of an electric centrifugal well pump calls for covering the pressure line during the curing and periodically starting the pump.

1983-01-01

262

A New Amidohydrolase from Bordetella or Alcaligenes Strain FB188 with Similarities to Histone Deacetylases  

UK PubMed Central (United Kingdom)

The full-length gene encoding the histone deacetylase (HDAC)-like amidohydrolase (HDAH) from Bordetella or Alcaligenes (Bordetella/Alcaligenes) strain...Full Text Available

2004-04-01

263

A Comparison of the Metabolic Fate of Fatty Acids of Different Chain Lengths in Developing Oilseeds  

UK PubMed Central (United Kingdom)

To determine if medium and long chain fatty acids can be appropriately metabolized by species that normally produce 16 and 18 carbon fatty acids, homogenates of developing Cuphea wrightii, Carthamus...Full Text Available

1989-07-01

264

30 CFR 75.211 - Roof testing and scaling.  

Science.gov (United States)

...d) A bar for taking down loose material shall be available in the working place or on all face equipment except haulage equipment. Bars provided for taking down loose material shall be of a length and design that will allow the removal of...

2010-07-01

265

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

266

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

267

Mathematical model of absorption of carbon dioxide by rescur breathing apparatus scrubber  

Energy Technology Data Exchange (ETDEWEB)

The author presents a mathematical model for analysis of the impact of scrubber bed length, porosity, and gas flow rate on the absorption of CO{sub 2} in a breathing apparatus. The model accounts for the decrease in available absorbent through chemical conversion. The predicted efflux of CO{sub 2} from a canister containing LiOH compared favorably with measured values reported elsewhere. It was determined from a computational study that the time for breakthrough of CO{sub 2} at a prescribed level is nearly directly proportional to bed length and inversely proportional to gas flow and porosity.

1987-01-01

268

Influence of oxygen precipitates on the measurement of minority carrier diffusion length in p-type silicon material using surface photovoltage technique  

Science.gov (United States)

Metallic contamination was monitored with Surface Photovoltage (SPV) technique in integrated circuit manufacturing facilities. Conventionally, Czochralski silicon bulk materials were used as monitor wafers. However, it has been observed that the diffusion length and the `Iron' concentration measured with SPV were inconsistent from run to run in one facility. The inconsistency is believed to be due to oxygen precipitate in silicon materials during the thermal cycle. By using low oxygen concentration or Float Zone wafers, metallic contaminants can be monitored more accurately and consistently.

1997-09-01

269

Gravitational Waves and the Sagnac Effect  

CERN Document Server

We consider light waves propagating clockwise and other light waves propagating counterclockwise around a closed path in a plane (theoretically with the help of stationary mirrors). The time difference between the two light propagating path orientations constitutes the Sagnac effect. The general relativistic expression for the Sagnac effect is discussed. It is shown that a gravitational wave incident to the light beams at an arbitrary angle will not induce a Sagnac effect so long as the wave length of the weak gravitational wave is long on the length scale of the closed light beam paths. The gravitational wave induced Sagnac effect is thereby null.

2003-01-01

270

Geometry changes transient transport in plasmas  

Energy Technology Data Exchange (ETDEWEB)

Role of ballooning effect in toroidal plasmas on the transient transport problems is investigated. Due to the mode localization along the magnetic field line, a meso scale appears in a radial correlation length of fluctuating fields. This scale length introduces the interference of the gradient and flux in different radial locations. For the fluctuation which gives the gyro-Bohm-like diffusion in a stationary state, this long radial correlation of the fluctuating field causes a fast propagation of response against a rapid transient perturbation. Upper bound of transient thermal diffusivity is derived. (author)

2001-06-01

271

Experimental Uncertainty for the Thermal Expansion of a Simulated Fuel  

Energy Technology Data Exchange (ETDEWEB)

Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.

2006-07-01

272

Asymptotic estimates for the number of solutions of the dualization problem and its generalizations  

British Library Electronic Table of Contents (United Kingdom)

Asymptotic estimates for the typical number of irreducible coverings and the typical length of an irreducible covering of a Boolean matrix are obtained in the case when the number of rows is no less than the number of columns. As a consequence, asymptotic estimates are obtained for the typical number of maximal conjunctions and the typical rank of a maximal conjunction of a monotone Boolean function of variables defined by a conjunctive normal form of clauses. Similar estimates are given for the number of irredundant coverings and the length of an irredundant covering of an integer matrix (for the number of maximal conjunctions and the rank of a maximal conjunction of a two-valued logical function defined by its zero set). Results obtained previously in this area are overviewed.

2011-01-01

273

The vasopressin mRNA poly(A) tract is unusually long and increases during stimulation of vasopressin gene expression in vivo  

Energy Technology Data Exchange (ETDEWEB)

The authors developed a method, termed an H-blot, by which the poly(A) tract of any specific mRNA may be detected by RNA filter hybridization after its removal from the body of the mRNA by a RNase H-catalyzed endonucleolytic cleavage in the 3' untranslated region. Using this method, they studied the modulation of the length of the poly(A) tract of rat vasopressin mRNA in vivo during changes in the levels of this mRNA resulting from a physiologic stimulus, osmotic stress. The poly(A) tract of hypothalamic vasopressin mRNA in hydrated rats was, quite remarkably, --250 nucleotides in length, in contrast to that of somatostatin mRNA, which was --30 nucleotides long. Vasopressin mRNA poly(A) tail length increased progressively from --250 to --400 nucleotides with the application of the hyperosmotic stimulus and declined to base line after its removal; somatostatin mRNA poly(A) tail length did not ...

1988-06-01

274

Testing and design of radon resisting membranes based on the experience from the Czech Republic  

International Nuclear Information System (INIS)

Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10"-"1"5 m"2/s to 10"-"8 m"2/s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is trying to show that controlling applicability of membranes by setting of the upper ...

275

uv photobiology: postreplication repair. [Escherichia coli, synchrotron radiation  

Science.gov (United States)

The following topics are discussed: insertion of incorrect bases in DNA; ability of DNA polymerase to copy uv-irradiated DNA; role of enzymes in repair of DNA; effects of uv radiation on molecular weight of DNA; photoreactivation; repair of DNA in Escherichia coli and xp cells following uv radiation; and synchrotron radiation studies on DNA repair. (HLW)

1978-01-01

278

Tumorigenic and tumoricidal actions of ionizing radiations  

Energy Technology Data Exchange (ETDEWEB)

The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.

1983-01-01

279

The influence of stray radiation on image quality  

International Nuclear Information System (INIS)

The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).

282

Surprising collectivity in neutron-rich iron isotopes  

International Nuclear Information System (INIS)

... VDPEAZ (Bonn 2010 issue) NUCLEAR PHYSICS AND RADIATION PHYSICS

2010-03-15

287

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

289

Solar Radiation Pressure Binning for the Geosynchronous Orbit  

Science.gov (United States)

Orbital maintenance parameters for individual satellites or groups of satellites have traditionally

2011-01-01

290

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

292

Radiological equipment for emergencies  

Energy Technology Data Exchange (ETDEWEB)

A brief guide to training and equipment needed to effectively manage victims of radiation accidents. (DT)

1985-01-01

296

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).

297

Radiation processing used in forestry in Thailand  

Energy Technology Data Exchange (ETDEWEB)

A summary is presented of research being carried out in Thailand on the preparation of irradiation-impregnated wood.

1981-01-01

298

Radiation effects on the shoot tip culture of chrysanthemum  

International Nuclear Information System (INIS)

Japanese (Mar 1974). Japan Mabuchi, Toshio Kuwada, Hikaru . Kagawa Univ.,

301

Radiation and fetal brain development  

International Nuclear Information System (INIS)

(4 Sep 1986). United Kingdom Zamenhof, Stephen . California Univ., Los

302

Radiation Protection of the Organism (Selected Chapters)  

Science.gov (United States)

... biologically important compounds is sharply lowered with passage of the solutions to the cell an organ, where their sensitivity ...

1970-12-11

303
305

Possibility of production of new superheavy nuclei in complete fusion reactions  

International Nuclear Information System (INIS)

... of Sciences (Poland) [5.48 Megabytes] NUCLEAR PHYSICS AND RADIATION

2008-09-01

306

Nuclear physics with a free electron laser  

International Nuclear Information System (INIS)

... radiation parity photonuclear reactions polarized beams resonance

308

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

309

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

311

Kinetics of low-temperature radiation hardening of metallic materials under irradiation  

British Library Electronic Table of Contents (United Kingdom)

A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.

2011-01-01

313

Infrared processes in the auroral zone  

International Nuclear Information System (INIS)

... aurorae carbon dioxide emission spectra infrared radiation nitrogen nitrogen

8432-01-01

315

Induced radiation during scattering of channeled electrons and positrons by point defects  

Energy Technology Data Exchange (ETDEWEB)

In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.

1984-12-01

319

ISR site  

CERN Document Server

A last look at the green field, in the triangular wedge of land stray radiation near the CERN accelerators.

1965-01-01

320

Free radicals in lysozyme reacted with peroxidizing methyl linoleate  

International Nuclear Information System (INIS)

... electron spin resonance gamma radiation lipids lyophilization lysozyme radicals

321

Four cases of bowel perforation following radiation therapy for cervical cancer  

Energy Technology Data Exchange (ETDEWEB)

External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.

1984-10-01

322

Experts' discussion on the possibility of quantification of the radiation hazard  

International Nuclear Information System (INIS)

Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).

1978-01-01

325

Effective dose equivalent in nuclear medicine investigations  

International Nuclear Information System (INIS)

... radiation hazards hazards health hazards MEDICINE. SOMATICALLY

1984-05-07

328

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

329

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

330

Cooperative spontaneous emission from two different atoms  

International Nuclear Information System (INIS)

The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).

1986-01-01

332

Comparing two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the hypofractionated treatment of high-risk prostate cancer  

UK PubMed Central (United Kingdom)

BackgroundTo compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated...Full Text Available

333

Cluster-loop structure influence on molybdenum radiation hardening  

International Nuclear Information System (INIS)

Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).

1990-05-22

339

About tachyons  

International Nuclear Information System (INIS)

... Part A: The electromagnetic radiation of a charged tachyon. Part B: Some

340

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

342

Theory of edge radiation  

CERN Document Server

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge ...

2008-01-01

343

Radiative corrections to the atomic levels in a periodic electromagnetic field  

Energy Technology Data Exchange (ETDEWEB)

The influence of a periodic electromagnetic field on the radiative corrections to the atomic energy levels is studied for the case of ''strong fields'' for which the interaction between the atom and field is of the order or greater than the radiative effects. The analysis is carried out on the basis of the Schwinger-Dirac equation for the propagation function of a bound electron in the field and on the basis of the density matrix in the Furry representation. It is shown that in the strong field approximation the radiative shifts and widths are manifest as radiative corrections to the quasi-energies. In super-high resolution experiments intensity effects in the radiative corrections to the atomic levels are obtained in the case of single-photon resonance. Some multiphoton processes are condidered by taking into account the effect of the field on ...

1982-12-01

344

Biological radiation effects  

International Nuclear Information System (INIS)

The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable alterations in tissues and ...

1976-01-01

345

A study on the real-time radiation dosimetry measurement system based on optically stimulated luminescence  

International Nuclear Information System (INIS)

The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...

2008-05-01

346

Radiological concepts in radiotherapy  

International Nuclear Information System (INIS)

The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...

347

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

348

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

349

Study of emission of Cerenkov radiation by tachyons  

International Nuclear Information System (INIS)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation. (author).

350

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

351

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

352

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

353

Radiation-stimulated diffusion of aerosols  

Energy Technology Data Exchange (ETDEWEB)

The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.

1984-04-01

354

Radiation-induced chemical modification of wood  

International Nuclear Information System (INIS)

The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.

1985-01-01

355

RADSOLVER: a computer program for calculating spectrally-dependent radiative heat transfer in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.

1981-09-01

356

Practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc

2004-05-01

357

New concepts in risk assessment for patients with radiological treatment  

International Nuclear Information System (INIS)

In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.

1986-01-01

358

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

359

Difference between delayed radiation-necroses of the cerebral hemispheres and midline: its bearing in radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.

1980-08-01

360

Decommissioning and dismantling. Examination of the radiation hardening of electronic components. Final report  

International Nuclear Information System (INIS)

Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).

361

Comparison and analysis of results of ? radiation level investigation around Daya Bay  

International Nuclear Information System (INIS)

Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)

2003-08-01

362

Biological Research for Radiation Protection  

International Nuclear Information System (INIS)

The work scope of 'Biological Research for the Radiation Protection' had contained the research about ornithine decarboxylase and its controlling proteins, thioredoxin, peroxiredoxin, S-adenosymethionine decarboxylase, and glutamate decarboxylase 67KD effect on the cell death triggered ionizing radiation and H_2O_2(toxic agents). In this study, to elucidate the role of these proteins in the ionizing radiation (or H_2O_2)-induced apoptotic cell death, we utilized sensesed (or antisensed) cells, which overexpress (or down-regulate) RNAs associated with these proteins biosynthesis, and investigated the effects of these genes on the cytotoxicity caused by ionizing radiation and H_2O_2(or paraquat). We also investigated whether genisteine(or thiamine) may enhance the cytotoxic efficacy of tumor cells caused by ionizing radiation (may enhance the preventing effect ...

363

Experimental studies of 4-inch pipe whip test under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous circumferential guillotine break of primary coolant piping in nuclear power plants. The present paper describes the results of the pipe whip tests using test pipes of 4 inch diameter, under the BWR LOCA conditions, which were performed from 1979 to 1981. The tests were carried out at an initial pressure of about 6.8 MPa and an initial temperature of about 285/sup 0/C. The test pipe was 114.3 mm (4 in) in diameter, 8.6 mm in thickness and 4500 mm in length. The four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and frabricated from Type 304 stainless steel. The experimental parameters were the clearance (30, 50 and 100 mm) and the overhang length (250, 400, 550 and 1000 mm). The main purpose of these tests is to investigate the effects of the clearance and the overhang ...

1983-10-01

364

Synchrotron radiation from electron beams in plasma-focusing channels.  

Science.gov (United States)

Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron distribution. This leads to a ...

2002-05-20

365

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and ...

1986-01-01

366

Radiation therapy in the treatment of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

The incidence of hilar cholangiocarcinoma is very rare worldwide. Radical resection is the only prognostic factor for long survival in patients with hilar cholangiocarcinoma. Postoperative radiation therapy can improve local control and survival rates for patients with palliative resection, but it remains controversial in patients with radical resection. Biliary drainage can effectively release bile duct obstruction for the majority of patients with locally advanced disease, and may even prolong survival when combined with radiation therapy. Radiation therapy includes extrernal beam therapy alone, external beam therapy with intraluminal brachytheapy and new radiation technique, such as three dimentional conformal therapy and intensity modulated radiation therapy. The propective randomized clinical study is needed for further investigation in the role of combined modality therapy ...

2007-10-01

367

Radiation receiver. Strahlungsempfaenger  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the invention is to improve a radiation receiver, consisting of a hollow body with an opening for the entry of radiation and a ceramic absorber situated in the hollow body, which absorbs the radiation energy entering through the opening, and emits it as thermal radiation to a heat medium, so that a higher efficiency can be achieved. According to the invention, the problem is solved by the fact that the absorber consists of ceramic material on the side towards the solar radiation, which has a low emission value and a high absorption value, and that the side of the absorber towards the heat medium has ceramic material of high emission value and low absorption value. This ensures that reradiation is prevented near the opening of the hollow body, and that the solar energy entering is largely absorbed in the hollow body.

1981-10-01

368

Radiation hardening of smart electronics  

International Nuclear Information System (INIS)

Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and ...

369

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

370

Ionizing radiation effect on sealant properties  

International Nuclear Information System (INIS)

Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.

371

Compare analysis of efficiency of using of digital and analog regimes of registration of radiation in radiometric systems of radiation thickness measuring  

International Nuclear Information System (INIS)

A consideration is given to the problem of selecting optimized methods of radionuclide radiation registration during the control of the objects with essential changes in thickness. Adequate model of information signal formation is developed and analyzed for the case of the existence of an inertial link of the system with the dead time of a noncontinued type. The boundary values of radiation thickness and radiation flux intensity that divide the priority of using either digital or analog registration modes are revealed. The method is found for the full correction of a systematic error of flux intensity measurement because of the dead time of the apparatus. To control the objects with essential variation of thickness the method of selective measurement of radiation intensity is proposed

372

Basic mechanisms of radiation effects in the natural space radiation environment  

Energy Technology Data Exchange (ETDEWEB)

Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)

1994-06-01

373

The quantum N-body problem with a minimal length  

CERN Document Server

The quantum $N$-body problem is studied in the context of nonrelativistic quantum mechanics with a one-dimensional deformed Heisenberg algebra of the form $[\\hat x,\\hat p]=i(1+\\beta \\hat p^2)$, leading to the existence of a minimal observable length $\\sqrt\\beta$. For a generic pairwise interaction potential, analytical formulas are obtained that allow to estimate the ground-state energy of the $N$-body system by finding the ground-state energy of a corresponding two-body problem. It is first shown that, in the harmonic oscillator case, the $\\beta$-dependent term grows faster with $N$ than the $\\beta$-independent one. Then, it is argued that such a behavior should be observed also with generic potentials and for $D$-dimensional systems. In consequence, quantum $N$-body bound states might be interesting places to look at nontrivial manifestations of a minimal length since, the more particles are present, the more the system deviates from ...

2010-01-01

374

Photoperiodic regulation of body mass and fat reserves in the meadow vole.  

Science.gov (United States)

Short photoperiods reduce both body mass and food intake of male meadow voles. To help determine whether the primary effect of short day lengths is on regulation of some component of body mass or on the control of food consumption, voles housed in a long photoperiod were provided rations equivalent to those consumed by animals in short day lengths. Animals were transferred to a short photoperiod and after either 3 or 6 weeks of food restriction were fed ad lib. Both groups of voles overate after termination of food restriction and achieved seasonally appropriate body masses that were influenced by the duration of short photoperiod treatment. We conclude that short photoperiods gradually alter the regulated level of one or more components of body mass. We tested and failed to support the hypothesis that the subcutaneous fat depot is selectively spared during seasonal weight loss and thereby increases surface insulation. Thus, the proportion of ...

1986-01-01

375

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). ...

2004-01-01

376

Natural climate variability as indicated by glaciers and implications for climate change: a modeling study  

Energy Technology Data Exchange (ETDEWEB)

Glacier fluctuations exclusively due to internal variations in the climate system are simulated using downscaled integrations of the ECHAM4/OPYC coupled general circulation model (GCM). A process-based modeling approach using a mass balance model of intermediate complexity and a dynamic ice flow model considering simple shearing flow and sliding are applied. Multi-millennia records of glacier length fluctuations for Nigardsbreen (Norway) and Rhonegletscher (Switzerland) are simulated using auto-regressive processes determined by statistically downscaled GCM experiments. Return periods and probabilities of specific glacier length changes using GCM integrations excluding external forcings such as solar irradiation changes, volcanic or anthropogenic effects are analyzed and compared to historical glacier length records. Preindustrial fluctuations of the glaciers as far as observed or reconstructed, including their advance ...

2001-08-01

377

High genetic diversity of HIV-1 was found in men who have sex with men in Shijiazhuang, China  

British Library Electronic Table of Contents (United Kingdom)

Men who have sex with men (MSM) have become one of the populations with severely HIV prevalence in China. However, very few genetic studies have been done on HIV-1 spreading in this population. In this study, the genetic characterization of HIV-1 strains prevalent in the MSM in Shijiazhuang, China, was analyzed basing on the HIV-1 full-length gag, pol, and partial env gene. 21 drug-naive HIV-1 sero-positive patients were enrolled into the study. Full length gag, pol, partial env genes and some near full length genomes were amplified with nest RT-PCR followed by sequencing. Multiple subtypes, including CRF01_AE (52.9%), subtype B (35.3%) and CRF07_BC (11.8%), were found in the population. Phylogenetic analysis showed close relationship between our strains with those from Beijing MSM but not...

2011-01-01

378

Final phase testing and evaluation of the 500 kW direct contact pilot plant at East Mesa  

Energy Technology Data Exchange (ETDEWEB)

The testing performed during the last phase of the geothermal direct contact heat exchanger program utilizing the 500 kW pilot plant provided more insight into the capabilities and limits of the direct contact approach and showed that more work needs to be done to understand the inner workings of a large direct contact heat exchanger if they are to be modeled analytically. Testing of the column demonstrated that the performance was excellent and that the sizing criteria is conservative. The system operated smoothly and was readily controlled over a wide range of operating conditions. Performance evaluation showed pinch differentials of 4/sup 0/F or less and better than predicted heat transfer capability. Testing during this final phase was directed towards establishing the limits of the column to transfer heat. The working column height was shortened progressively to approximately 16 feet from a design length of 28 feet. The short column performed as well as a full ...

1983-12-01

379

Fabrication and animal experiment of nanocomposites of hydroxyapatite collagen and polysaccharides  

Energy Technology Data Exchange (ETDEWEB)

Four species of nanocomposites organized by hydroxyapatite (HAp), hyaluronic acid (HyA), chondroitin sulfate (ChS) and type II collagen (Col), i.e. HAp/HyA, HAp/ChS, HAp/HyA/Col and HAp/ChS/Col composites, were synthesized by coprecipitation methods. The composites could retain lots of water: 40%, 32%, 42% and 58% for the HAp/HyA, HAp/ChS, HAp/HyA/Col and HAp/ChS/Col composites, respectively. Transmission electron microscopy observations revealed that the HAp/HyA and HAp/ChS composites consisted of island-like aggregations whose sizes were 300 nm in length and 30 nm in width, and 150 nm in length and 30 nm in width, respectively. In the aggregations, there were many HAp nanocrystals of 20 nm in length, and their c-axes were aligned along the respective polymer molecules through a self-organization process. Animal tests showed that chondrocyte-like cells penetrated into the HAp/ChS/Col composites 4 weeks after implantation. ...

2001-07-01

380

Ectopic expression of wild-type or a dominant-negative mutant of transcription factor NTF-1 disrupts normal Drosophila development.  

Science.gov (United States)

The Drosophila melanogaster tissue-specific transcription factor NTF-1 was originally identified in vitro as a protein that could bind to and activate transcription from the Dopa decarboxylase (Ddc) gene. A structure-function analysis of NTF-1 led to the identification of a discrete amino-terminal activation domain. Here, we report that an NTF-1 mutant lacking the activation domain acts as a trans-dominant inhibitor of NTF-1 activation in tissue culture cells by forming inactive heterodimers with the full-length protein. Ectopically expressing this dominant-negative protein or the full-length protein in developing Drosophila embryos leads to dire developmental consequences. Overexpressing the trans-dominant NTF-1 leads to lethality, while overexpressing full-length NTF-1 results in both lethality and morphogenetic defects. Our results suggest that both the activity and the regulation of NTF-1 are critical for viability and ...

1993-11-15

381

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present plain flat tube showed ...

2011-01-15

382

The effects of cosmic radiation on implantable medical devices  

Energy Technology Data Exchange (ETDEWEB)

Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main ...

1996-12-31

383

Packaging materials for use in radiation processing of foods  

International Nuclear Information System (INIS)

In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, ...

384

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder ...

2003-03-04

385

Torsional responses of double-walled carbon nanotubes via molecular dynamics simulations  

Energy Technology Data Exchange (ETDEWEB)

The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.

2008-11-12

386

The number of cycles of specified normalized length in permutations  

CERN Document Server

We compute the limiting distribution, as n approaches infinity, of the number of cycles of length between gamma n and delta n in a permutation of [n] chosen uniformly at random, for constants gamma, delta such that 1/(k+1) <= gamma < delta <= 1/k for some integer k. This distribution is supported on {0, 1, ... k} and has 0th, 1st, ..., kth moments equal to those of a Poisson distribution with parameter log (delta/gamma). For more general choices of gamma, delta we show that such a limiting distribution exists, which can be given explicitly in terms of certain integrals over intersections of hypercubes with half-spaces; these integrals are analytically intractable but a recurrence specifying them can be given. The results herein provide a basis of comparison for similar statistics on restricted classes of permutations.

2009-01-01

387

The new JET phased ICRH array: first experiments and modelling  

Energy Technology Data Exchange (ETDEWEB)

New ICRH antennas on JET were designed to couple to the new JET divertor plasma configurations and to improve the Fast Wave Current Drive (FWCD) capabilities. The A2 antenna consists of 4 straps whose currents can be phased at arbitrary angles. The real time automatic tuning acts on frequency, line length (line phase shifters) and stub length. Provision is made for the coupling resistance/plasma position feedback to accommodate the fast changes in antenna loading. The first coupling, tuning and heating results are reported in 0{pi}0{pi}, 0000 and 00{pi}{pi} phasing. A new antenna model is described, which was developed to simulate the measured antenna loading in terms of plasma parameters and to provide a starting point for the real time automatic tuning. 5 refs., 4 figs.

1994-07-01

388

The effects of curvature and surface heterogeneity on the adsorption of water in finite length carbon nanopores: a computer simulation study  

British Library Electronic Table of Contents (United Kingdom)

The effects of pore curvature and surface heterogeneity on the adsorption of water on a graphitic surface at 298 K were investigated using a Grand Canonical Monte Carlo (GCMC) simulation. Slit and cylindrical pores are used to study the curvature effects. To investigate the surface heterogeneity the functional group and the structural defect on the surface were specifically considered. The hydroxyl group (OH) is used as a model for the functional group and the water potential model proposed by Muller et al. is used to calculate the water interaction. For the homogeneous cylinder, the pore filling occurs at a pressure lower than the saturation pressure of the water model, while it is greater in the case of homogeneous slit pore. The size of hysteresis loop is more sensitive to the length of...

2008-01-01

389

The dependence of the temperature of crystal-liquid phase transition on the size and shape of simple nanocrystal  

British Library Electronic Table of Contents (United Kingdom)

The dependence of melting temperature T m on the size and shape of an n -dimensional nanocrystal of elementary single-component substance is studied. The nanocrystal has the form of an n-dimensional parallelepiped with a square base. The ratio of the length of side rib to the length of base rib (which is equal to f) defines the form of the system. It is demonstrated that, if the surface pressure is ignored, the value of T m decreases with isomorphic (f = const) decrease in the size of nanocrystal. In so doing, the more the value of form parameter f deviates from unity, the more appreciable the size dependence of T m will be. However, if the surface pressure (?Laplace pressure??) is taken into account in the case of decrease in size, the value of T m may vary significantly. In so doing, if ...

2009-01-01

390

The Bipolar Field-Effect Transistor: VIII. Longitudinal Gradient of Longitudinal Electric Field (Two-MOS-Gates on Pure-Base)  

International Nuclear Information System (INIS)

This paper evaluates the electric current terms from the longitudinal gradient of the longitudinal electric field in Bipolar Field-Effect-Transistors (BiFETs) with a pure base and two MOS gates operating in the unipolar (electron) current mode. These nMOS-BiFETs, known as nMOS-FinFETs, usually have electrically short channels compared with their intrinsic Debye length of about 25 #mu#m at room temperatures. These longitudinal electric current terms are important short-channel current components, which have been neglected in the computation of the long-channel electrical characteristics. This paper shows that the long-channel electrical characteristics are substantially modified by the longitudinal electrical current terms when the physical channel length is less than 100 nm.

2010-07-01

391

Sodium monocarboxylates as inhibitors of AZ31 alloy corrosion in a synthetic cooling water  

Energy Technology Data Exchange (ETDEWEB)

This research investigated the inhibiting effects that sodium salts of linear monocarboxylic acids displayed towards the corrosion process of AZ31 Mg alloy in ASTM D 1387 saline solution (a synthetic industrial cooling water). The length of the aliphatic chain of the acids ranged between 7 and 15 carbon atoms. The inhibiting action of these salts can be related to the precipitation of an insoluble magnesium salt, which mainly affected the anodic reaction. The aliphatic chain length controlled the anion solubility and the reaction rate of magnesium carboxylate formation. For all the salts, an optimum concentration was experienced: 10{sup -2} M for sodium decanoate (caprate), 10{sup -3} M for sodium dodecanoate (laurate), 10{sup -4} M for sodium tetradecanoate (myristate); when this concentration was exceeded, a diminution (even a disappearance) in the inhibiting action was found. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

2009-03-15

392

Proposal for a commercial interconnection among the Hawaiian islands based on the results of the Hawaii deep water cable program  

Energy Technology Data Exchange (ETDEWEB)

After the successful completion of the development program of the 2000 m water depth HVDC Hawaii Deep Water Self Contained Fluid Filled Cable, the interconnection between Hawaii island and Oahu island is examined. Thermal, electrical, mechanical, hydraulic, corrosion, length aspects are developed for both fluid filled and paper impregnated (SOLID) cables which are foreseen in different portions of the approximately 250 km length connection. Considerations are also presented for the requirements of the cable ship: 12 m sheave diameter, 7000 t capacity for the rotating platform. The feasibility of manufacturing, transporting and laying such cables within a practical schedule is discussed in this paper.

1992-10-01

393

Parametric study of pipe whip behavior  

International Nuclear Information System (INIS)

A pipe whip test is one of the main subjects of the pipe rupture tests performed in Japan Atomic Energy Research Institute. In 1979, the pipe whip test of 4B, sch-80 pipe will be done under the BWR condition. As the preliminary analysis of this test, the pipe whip analysis of 4B, sch-80 pipe was implemented in order to make clear of the influences of the physical parameters on the pipe whip behavior. The pipe whip analysis was treated as nonlinear dynamic analysis of pipe-restraint system by using the general purpose finite element program ADINA. Overhang length, clearance between pipe and restraint, restraint length and cross section area of restraint were taken as physical parameters. It was clarified through this analysis how restraint displacement, restraint strain and distribution of energy between pipe and restraint were influenced by these parameters. (author).

394

On the parameterization of the roughness length for the air-sea interface in free convection for the coastal site Tarapur, India  

International Nuclear Information System (INIS)

The roughness length at air-sea interface during free convection (Z0fc) is mainly related to the convective velocity (w) rather than the friction velocity (u). The parameterization of Z0fc with (w)2/g as proposed by Abdella and D'Alessio (2003) is evaluated. It is shown that the field measurements at MM Lab, Tarapur Maharashtra Site (TMS) coastal site using Metek GmbH, Ultra sonic anemometers are consistent with the proposed formula. In order to avoid self-correlation by using u, a new parameterization of w with ?u and ?v and gustiness parameter as given by Fairall et al. (1996) is used. The mean values of w and Z0fc estimated using new parameterization were observed to be 0.97 m/s and 2.3E-4 m respectively for the year 2009 at TMS. (author)

2010-05-13

395

Numerical simulation of conformational variability in biopolymer translocation through wide nanopores  

CERN Document Server

Numerical results on the translocation of long biopolymers through mid-sized and wide pores are presented. The simulations are based on a novel methodology which couples molecular motion to a mesoscopic fluid solvent. Thousands of events of long polymers (up to 8000 monomers) are monitored as they pass through nanopores. Comparison between the different pore sizes shows that wide pores can host a larger number of multiple biopolymer segments, as compared to smaller pores. The simulations provide clear evidence of folding quantization in the translocation process as the biopolymers undertake multi-folded configurations, characterized by a well-defined integer number of folds. Accordingly, the translocation time is no longer represented by a single-exponent power law dependence on the length, as it is the case for single-file translocation through narrow pores. The folding quantization increases with the biopolymer length, while the rate of ...

2009-01-01

396

Molecular structure of platinum(III) hydroxoacetates according to data from EXAFS spectra  

Energy Technology Data Exchange (ETDEWEB)

The EXAFS spectra of the platinum(III) complexes Pt/sub 4/(OAc)/sub 10/(OH)/sub 2/ (I) and Pt/sub 4/ (OAc)/sub 4/(OH)/sub 8/(H/sub 2/O)/sub 2/ (II) have been investigated. It has been found by a curve-fitting method and with the aid of Fourier transformations that the shortest Pt-Pt distances are 2.61 A in complex I and 2.36 and 2.6 A in II. The values of the bond lengths obtained are consistent with the molecular structures proposed for complexes I and II, which contain skeletons of four platinum atoms in the form of a square or a rectangle, as well as with the known literature data on the lengths of Pt-Pt bonds in Pt(III) complexes.

1986-04-01

397

Modelling the effects of measured anode triple-phase boundary densities on the performance of micro-tubular hollow fiber SOFCs  

British Library Electronic Table of Contents (United Kingdom)

The percolated or active triple phase boundary (TPB) length per unit volume of Ni-YSZ anode hollow fibers (HFs) containing 60wt.% initial NiO and a spatially varying microstructure were measured using a focused ion beam (FIB)-SEM technique. The measured values of contiguous TPB density were interfaced with a 2-D distributed finite element model of a hollow fiber solid oxide fuel cell. The model was applied to simultaneously solve the ionic and electronic charge balances in the electrodes, which were modelled as overlying continuum materials with effective electronic and ionic conductivities. The model was used to predict the effects of anode microstructure on the distribution of current density, and anode activation polarization. Active TPB lengths of 2.63-8.63 m^-^2 were measured for the ...

2011-01-01

398

Minimum Redundancy Coding for Uncertain Sources  

CERN Document Server

Consider the set of source distributions within a fixed maximum relative entropy with respect to a given nominal distribution. Lossless source coding over this relative entropy ball can be approached in more than one way. A problem previously considered is finding a minimax average length source code. The minimizing players are the codeword lengths --- real numbers for arithmetic codes, integers for prefix codes --- while the maximizing players are the uncertain source distributions. Another traditional minimizing objective is the first one considered here, maximum (average) redundancy. This problem reduces to an extension of an exponential Huffman objective treated in the literature but heretofore without direct practical application. In addition to these, this paper examines the related problem of maximal minimax pointwise redundancy and the problem considered by Gawrychowski and Gagie, which, for a sufficiently small relative entropy ball, ...

2011-01-01

399

Microcrystalline-Si thin-film transistors formed by using palladium silicided source/drain contact electrode  

British Library Electronic Table of Contents (United Kingdom)

Microcrystalline-Si thin-film transistors (?C-Si TFTs) formed by using the source/drain contact electrode of self-aligned palladium silicide have been investigated. Both the self-aligned palladium silicided scheme and the previous top-gate staggered structure employ two-mask process steps for fabricating ?C-Si TFTs. However, the self-aligned palladium silicided scheme would cause better device characteristics than the top-gate staggered structure, primarily due to more carrier tunneling. For a gate length of 2 ?m, as compared to the top-gate staggered scheme, this silicided scheme can result in a 40% improvement of on-state current. In addition, as the gate length is reduced to 1 ?m, considerable short-channel effect is caused for both the device schemes.

2010-01-01

400

Medical management of motility disorders in patients with intestinal failure: a focus on necrotizing enterocolitis, gastroschisis, and intestinal atresia  

British Library Electronic Table of Contents (United Kingdom)

Background: Intestinal failure (IF) is the dependence upon parenteral nutrition to maintain minimal energy requirements for growth and development. It may occur secondary to a loss of bowel length, disorders of motility, or both. Short bowel syndrome (SBS) is a malabsorptive state resulting from surgical resection, congenital defect, or diseases associated with loss of absorptive surface area. A particularly vexing problem is associated with whole bowel and/or segmental intestinal dysmotility. Motility disorders within the context of SBS and IF may relate to rapid intestinal transit secondary to loss of intestinal length, dysmotility associated with loss or poor antegrade peristalsis, or gastroparesis. Therapy may be classified into medical (prokinetic and antidiarrheal agents) and surgica...

2011-01-01

401

Measuring the scale of segregation in mixing data  

British Library Electronic Table of Contents (United Kingdom)

Abstract Four methods were used to extract length scales from mixing data: the maximum striation thickness, point-to-nearest-neighbour (PNN) distributions, the correlogram and the variogram. Four test data sets were analysed: blending in a micromixer; particle dispersion in a stirred tank; dispersion of a smoke plume and a pulse tracer test in a reactor. The maximum striation thickness captures the largest length scale. The PNN method quantifies differences between clustered, random and regular spatial distributions. The correlogram calculation cannot be consistently used for all types of mixing data and has therefore been rejected. The variogram reveals both large-scale segregation and periodicity. Sub-sampling is needed to isolate smaller structures. The variogram, PNN and transect metho...

2011-01-01

402

Longer exaggerated male genitalia confer defensive sperm-competitive benefits in an earwig  

British Library Electronic Table of Contents (United Kingdom)

As evidence mounts that male genitalia can affect relative fertilisation success, the role that sexual selection has played in the rapid and divergent evolution of genitalia is becoming increasingly recognized. Unfortunately, the limited functional understanding of these complex structures and their interactions with the female reproductive tract often limit interpretation regarding their evolution. Here, we address this issue using the earwig Euborellia brunneri, where both the male intromittent organ and the female spermatheca are highly exaggerated in length yet structurally simple. In a double mating design, we use the sterile male technique to study how sperm precedence patterns are affected by male genital length, male age, and the size of the male sperm storage organ, the seminal ve...

2011-01-01

403

Length-sorted semiconducting carbon nanotubes for high-mobility thin film transistors  

British Library Electronic Table of Contents (United Kingdom)

We have developed a process for chemical purification of carbon nanotubes for solution-processable thin-film transistors (TFTs) having high mobility. Films of the purified carbon nanotubes fabricated by simple drop coating showed carrier mobilities as high as 164 cm2V?1s?1, normalized transconductances of 0.78 Sm?1, and on/off current ratios of 106. Such high performance requires the preparation of a suspension of micrometer-long and highly purified semiconducting single-walled carbon nanotubes (SWCNTs). Our purification process includes length and electronic-type selective trapping of SWCNTs using recycling gel filtration with a mixture of surfactants. The results provide an important milestone toward printed high-speed and large-area electronics with roll-to-roll and ink-jet device fabri...

2011-01-01

404

Isolation of full-length putative rat lysophospholipase cDNA using improved methods for mRNA isolation and cDNA cloning  

Energy Technology Data Exchange (ETDEWEB)

The authors have cloned a full-length putative rat pancreatic lysophospholipase cDNA by an improved mRNA isolation method and cDNA cloning strategy using (/sup 32/P)-labelled nucleotides. These new methods allow the construction of a cDNA library from the adult rat pancreas in which the majority of recombinant clones contained complete sequences for the corresponding mRNAs. A previously recognized but unidentified long and relatively rare cDNA clone containing the entire sequence from the cap site at the 5' end to the poly(A) tail at the 3' end of the mRNA was isolated by single-step screening of the library. The size, amino acid composition, and the activity of the protein expressed in heterologous cells strongly suggest this mRNA codes for lysophospholipase.

1987-03-24

405

Influence of turbulence parameters, Reynolds number, and body shape on stagnation-region heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This experiment investigated the effects of free-stream turbulence intensity, length scale, Reynolds number, and leading-edge velocity gradient on stagnation-region heat transfer. Heat transfer was measured in the stagnation region of four models with elliptical leading edges downstream of five turbulence-generating grids. Stagnation-region heat transfer augmentation increased with decreasing length scale but an optimum scale was not found. A correlation was developed that fit heat transfer data for isotropic turbulence to within {+-}4 percent but did not predict data for anisotropic turbulence. Stagnation heat transfer augmentation caused by turbulence was unaffected by the velocity gradient. The data of other researchers compared well with the correlation. A method of predicting heat transfer downstream of the stagnation point was developed. 28 refs., 12 figs., 4 tabs.

1995-08-01

406

Influence of turbulence parameters, Reynolds number, and body shape on stagnation-region heat transfer  

International Nuclear Information System (INIS)

This experiment investigated the effects of free-stream turbulence intensity, length scale, Reynolds number, and leading-edge velocity gradient on stagnation-region heat transfer. Heat transfer was measured in the stagnation region of four models with elliptical leading edges downstream of five turbulence-generating grids. Stagnation-region heat transfer augmentation increased with decreasing length scale but an optimum scale was not found. A correlation was developed that fit heat transfer data for isotropic turbulence to within #+-#4 percent but did not predict data for anisotropic turbulence. Stagnation heat transfer augmentation caused by turbulence was unaffected by the velocity gradient. The data of other researchers compared well with the correlation. A method of predicting heat transfer downstream of the stagnation point was developed. 28 refs., 12 figs., 4 tabs.

1995-01-01

407

Impact of Tubing Length on Hemodynamics in a Simulated Neonatal Extracorporeal Life Support Circuit  

British Library Electronic Table of Contents (United Kingdom)

Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...

2010-01-01

408

Free-electron laser driven by the LBNL laser-plasma accelerator  

Energy Technology Data Exchange (ETDEWEB)

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

2008-08-04

409

Extremal behavior of a coupled continuous time random walk  

British Library Electronic Table of Contents (United Kingdom)

Coupled continuous time random walks (CTRWs) model normal and anomalous diffusion of random walkers by taking the sum of random jump lengths dependent on the random waiting times immediately preceding each jump. They are used to simulate diffusion-like processes in econophysics such as stock market fluctuations, where jumps represent financial market microstructure like log returns. In this and many other applications, the magnitude of the largest observations (e.g. a stock market crash) is of considerable importance in quantifying risk. We use a stochastic process called a coupled continuous time random maxima (CTRM) to determine the density governing the maximum jump length of a particle undergoing a CTRW. CTRM are similar to continuous time random walks but track maxima instead of sums....

2011-01-01

410

Experimental Investigation and RELAP5 Modeling of Two-Phase Flow in Horizontal Rectangular Channel  

British Library Electronic Table of Contents (United Kingdom)

The investigation of steam, water, and air flow characteristics in horizontal channel is a part of major investigations program at the Lithuanian Energy Institute. The objective of this program is to identify condensation effects on two-phase flow stability and to predict conditions when rapid condensation could be induced in two-phase condensable flow. This article presents investigation of steam-water and air multiphase flow in nearly horizontal rectangular channel. The experimental data for pressure drop and interfacial and wall shear stresses in the channel with uniform distribution of void fraction are presented in this paper. Overall channel dimensions are length = 1.2 m, width = 0.02 m, height = 0.1 m; however, the test section was about 0.84 m in length. Three different flow types ...

2011-01-01

411

Environmental quality assessment in estuarine ecosystems: Use of biometric measurements and fecundity of the ragworm Nereis diversicolor (Polychaeta, Nereididae)  

British Library Electronic Table of Contents (United Kingdom)

The ability to cope with environmental stress may be expensive in terms of energy and this cost of tolerance is suspected to have negative counterparts such as reduced growth and fecundity. To date, condition indices based on biometric measurements are currently used in bivalves or fish but do not exist in endobenthic worms, despite their interest as bioindicators for the sedimentary compartment in which the major part of pollutants is stored in aquatic environments. In the present work, several biometric variables (jaw and total body length, number of segments, the length of the first three segments L3, wet or dry weight) were measured in the ragworm Nereis diversicolor originating from clean (Authie) and polluted (Seine) estuaries (France) to study size-weight relationships. The producti...

2008-01-01

412

Effects of Tapered Betafunction in the LCLS Undulators  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) is an X-ray free-electron laser (FEL) project based on the SLAC linac [1]. With its nominal set of electron beam, focusing and undulator parameters, it is designed to achieve SASE saturation at an undulator length of about 100 m with an average power of 10 GW. In order to keep the electron beam focused in the undulators, a FODO lattice is integrated along the entire length of the undulators. Nominally, the quadrupole strengths are chosen to produce nearly constant betafunction and beam size along the undulator, optimized for the FEL interaction in the exponential growth regime. Since these quadrupoles are electromagnetic, it is possible to adjust the individual quadrupole strength to vary the betafunction and the beam size along the undulator, tailoring the FEL interaction in the start-up and the saturation regimes. In this paper, we present simulation studies of the tapered betafunction in the LCLS ...

2005-09-30

413

Correlations of /sup 195/Pt-/sup 31/P coupling constants with platinum-ligand and platinum-platinum bond lengths in platinum(I) dimers and in related platinum(II) complexes  

Energy Technology Data Exchange (ETDEWEB)

The availability of dimeric Pt(I) complexes with bridging bis(diphenylphosphino)methane ligands, (L--L')/sup n+/, presents an opportunity to study the physical properties and reactivity of metal-metal bonds as a function of the ligand trans to it with a minimum of competing variables. Several interesting trends of Pt-P coupling constants with the Pt-L and Pt-Pt bond lengths in Pt(I) dimers, (L--L')/sup n+/, and structurally related Pt(II) complexes are reported here. The data indicate that the Pt-P coupling constants continue to be sensitive indicators of not only the structure and stereochemistry of platinum phosphine complexes but also the electronic and steric influences of the ligand in such complexes, 23 references, 1 figure, 4 tables.

1986-03-12

414

Colour contrast in ballistic gelatine  

British Library Electronic Table of Contents (United Kingdom)

Gelatine is a reliable tissue simulant in wound ballistic experiments. The projectile penetrating the gelatine transfers energy and causes radial cracks according to the temporary cavity. Thus the crack length is a function of the energy spent in the medium. In practice the fissures are poorly contrasted for which reason an enhancement of contrast was searched. A series of six shoots with expanding bullets (9mmx19 Action-5, 9mmx19 Quick Defense 1, 5.56mmx45 Styx Action) was realized on 10% gelatine blocks at 4^oC temperature. Three blocks were marked with acryl paint on the front, three blocks were shot native. The blocks were cut in slices of 1cm thickness and optically scanned. The evaluation was performed according to Fackler's wound profile, the total crack length method and the polygo...

2010-01-01

415

Cloning and characteristics of Brn1 gene in Curvularia lunata causing leaf spot in maize  

British Library Electronic Table of Contents (United Kingdom)

The full length cDNA of the Brn1 was first cloned, and then expression of the Brn1 was analyzed and the function was identified by silencing technology. Results show that the full length cDNA of the C. lunata Brn1 gene contains 1001 base pairs and an 801?bp open reading frame encoding 267 amino acids. Semi-quantitative PCR analysis shows that the expression of Brn1 at 96?h is significantly higher than at 24 and 72?h (p?Brn1-silenced transformants were light brown in culture filtrate, and have significantly reduced toxin production relative to the wild-type. These results imply that Brn1 gene in C. lunata is not only involved in 1,8-dihydroxynaphthalene melanin synthesis, but is also relatively associated with toxin biosynthesis of the pathogen.

2011-01-01

416

Capturing recrystallization of metals with a multi-scale materials model  

Energy Technology Data Exchange (ETDEWEB)

The final report for a Laboratory Directed Research and Development project entitled, ``Capturing Recrystallization of Metals in a Multiscale Materials Model'' is presented. In this project, deformation and recrystallization processes have been followed experimentally and theoretically in order to incorporate essential mechanisms from the defect (dislocation) and grain size length scales. A nonlinear rotational gradient theory has been developed which enables the incorporation of microstructural parameters. The evolution of these parameters during deformation and recrystallization has been characterized qualitatively and quantitatively, applying various electron optic techniques ranging over several length scales. The theoretical and experimental framework developed is general. It has been exemplified by an application to recrystallization in single crystals and bicrystals of aluminum. The recrystallization process has been ...

2000-04-01

417

Calculation of 3-D free electron laser gain: Comparison with simulation and generalization to elliptical cross section  

Energy Technology Data Exchange (ETDEWEB)

In the previous paper, we have derived a dispersion relation for the free electron laser (FEL) gain in the exponential regime taking account the diffraction and electron`s betatron oscillation. Here, we compare the growth rates obtained by solving the dispersion relation with those obtained by simulation calculation for the waterbag and the Gaussian models for the electron`s transverse phase space distribution. The agreement is found to be good except for the limiting case where the Rayleigh length is much longer than the gain length (1-D limit). We also generalize the analysis to the case where the electron beam cross section is elliptical as is usually the case in storage rings, and derive the first-order dispersion relation.

1992-08-01

418

Application of a prognostic model validation system to real-time dispersion modeling  

Energy Technology Data Exchange (ETDEWEB)

The Atmospheric Release Advisory Capability (ARAC) at the Lawrence Livermore National Laboratory uses the U.S. Navy's Coupled Ocean/Atmosphere Mesoscale Prediction System (COAMPS) to supply high-resolution wind data for use in its real-time dispersion modeling system. ARAC has used COAMPS products to support several events and exercises, and COAMPS forecasts appear accurate, based on qualitative examination. Recently ARAC has developed a quantitative verification system which calculates COAMPS error and bias statistics, comparing COAMPS forecasts of various lengths with observational data. This paper shows how this system has been used to guide ARAC operators, who need an estimate of the likely behavior of COAMPS forecasts of various lengths in different regions, seasons, and weather patterns.

1999-10-18

419

Aerodynamic performance of thin wings at low Reynolds numbers  

British Library Electronic Table of Contents (United Kingdom)

Purpose - This study seeks to explore the aerodynamic performance of wings with different shapes at low Reynolds numbers. Design/methodology/approach - The airfoils of these wings are made from aluminum plates, and the maximum cord length and wingspan are 15?cm. Wings A to D are plates with 6 percent Gottingen camber but different wing planforms. The forward-half sections of wings E and F are dragonfly-like, whereas the rear-half sections of wings E and F are flat and positively cambered, respectively. The aspect ratios of these wings are close to one, and the ratios of plate thickness to the maximum cord length are 1.3 percent. Experimental results indicate that the wings with Gottingen camber have a superior lift and lift-to-drag ratio, whereas the wings with dragonfly-like airfoils perf...

2007-01-01

420

AWGN Channel Analysis of Terminated LDPC Convolutional Codes  

CERN Document Server

It has previously been shown that ensembles of terminated protograph-based low-density parity-check (LDPC) convolutional codes have a typical minimum distance that grows linearly with block length and that they are capable of achieving capacity approaching iterative decoding thresholds on the binary erasure channel (BEC). In this paper, we review a recent result that the dramatic threshold improvement obtained by terminating LDPC convolutional codes extends to the additive white Gaussian noise (AWGN) channel. Also, using a (3,6)-regular protograph-based LDPC convolutional code ensemble as an example, we perform an asymptotic trapping set analysis of terminated LDPC convolutional code ensembles. In addition to capacity approaching iterative decoding thresholds and linearly growing minimum distance, we find that the smallest non-empty trapping set of a terminated ensemble grows linearly with block length.

2011-01-01

421

A statistical evaluation of recent SSC conductors produced at IGC/ASI  

International Nuclear Information System (INIS)

One of the requirements for uniform field quality in the SSC dipole magnets is the consistency in the superconducting strand characteristics from start to finish to the production phase. As full scale production of strand and cable approaches, the consistency in performance of the early batches of conductor needs to be examined. A number of 300 mm billets have been manufactured at IGC with tight process controls. The performance of the final conductor in terms of piece lengths, current density, Cu/Sc ratio and wire diameter has been evaluated. The data are analyzed in order to understand the variations that are related to the conductor design and processing. In this paper the current density of the strand is examined over the length of the billet to determine inherent variability in the Nb/Ti alloy itself.

1990-09-24

422

A computational study of aluminum phosphide nanotubes  

British Library Electronic Table of Contents (United Kingdom)

Abstract Electronic structures of two representative zigzag and armchair models of aluminum phosphide nanotube (AlPNT) were investigated by density functional theory calculations. The structures were optimized and the bond lengths, tip diameters, band gaps, and dipole moments were calculated. Moreover, the quadrupole coupling constants (CQ) were calculated for the Al-27 atoms of the optimized structures. The same values of AlP bond lengths were calculated for both models. The larger value of band gap of armchair model than the zigzag model indicated the stronger dielectric property for the former model. The values of CQ(27Al) were the largest for the Al atoms placed at the tips of both zigzag and armchair AlPNT than other Al atoms, which could reveal dominant role of the Al atoms placed at...

2011-01-01

423

[Somatic radiation risk in conventional tomography of the skull and thorax].  

Science.gov (United States)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769

1982-10-01

424

[Malignant transformation of human fibroblasts by neutrons and by gamma radiation: Relationship to mutations induced  

Energy Technology Data Exchange (ETDEWEB)

A brief overview if provided of selected reports presented at the International Symposium on Molecular Mechanisms of Radiation- and Chemical Carcinogen-Induced Cell Transformation held at Mackinac Island, Michigan on September 19-23, 1993.

1993-12-31

425

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

426

What Parents Should Know about Medical Radiation Safety in Interventional Radiology  

Science.gov (United States)

... Amount Background Radiation Blood vessel central line, PICC (peripherally inserted central catheter) or port placement, simple 0.4 mSv ...

427

Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer  

UK PubMed Central (United Kingdom)

PurposeWe conducted a comparative study of Clinical Target Volume (CTV) definition of pelvic lymph nodes by multiple GU radiation oncologists looking at the levels...Full Text Available

2009-06-01

428

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

429

The relationship of time and space  

CERN Document Server

We show that, in addition to radiation travelling at the speed of light, QED theory predicts a second type of radiation with an infinite velocity. We also show that charge, as it appears in the Dirac equation, may have a triune nature.

2004-01-01

430

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

431

Targeted nanoparticles that deliver a sustained, specific release of paclitaxel to irradiated tumors  

UK PubMed Central (United Kingdom)

To capitalize on the response of tumor cells to ionizing radiation, we developed a controlled-release nanoparticle drug delivery system using a targeting peptide that recognizes a radiation-induced...Full Text Available

2010-06-01

432

Somatic radiation risk in conventional tomography of the skull and thorax  

Energy Technology Data Exchange (ETDEWEB)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.

1982-10-01

433

Somatic radiation risk in conventional tomography of the skull and thorax  

International Nuclear Information System (INIS)

The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).

1982-01-01

434

Simvastatin ameliorates radiation enteropathy development after localized, fractionated irradiation by a protein C-independent mechanism  

UK PubMed Central (United Kingdom)

BackgroundMicrovascular injury plays a key role in normal tissue radiation responses. Statins, in addition to their lipid-lowering effects, have vasculoprotective...Full Text Available

2007-08-01

435

Shield-verification survey of a large hot cell at the FFTF  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a radiation shield verification survey of a large hot cell at the Fast Flux Test Facility (FFTF). The following aspects of the shield test are discussed: description of the FFTF; description of the hot cell; the test procedures; radiation protection, and the test results.

1980-01-01

436

Radiative transfer in a solar absorbing particle laden flow  

Science.gov (United States)

A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength dependence of the optical ...

1985-11-01

437

Radiation, adriamycin, and skin reactions: effects of radiation and drug fractionation, hyperthermia, and tetracycline. [X rays  

Energy Technology Data Exchange (ETDEWEB)

The effect of adriamycin in combination with radiation on the skin reactions of mouse feet has been examined under a variety of experimental conditions including: (a) hyperthermic treatment of the foot immediately following adriamycin administration, with the former given either just before or just after x irradiation, and (b) fractionated treatments of drug and radiation in a variety of sequences over an 18-day period. In the case of the most severe hyperthermic treatment, no increased radiation reactions were observed in the presence of adriamycin. However, in the case of the less severe hyperthermic treatment a small but significant increase in skin reactions was observed. In the study of fractionated drug and radiation treatments, an enhancement of reaction in those animals receiving combined modality treatment over those receiving radiation alone was seen in those groups where ...

1981-06-01

438

Radiation risks for medical applications  

International Nuclear Information System (INIS)

The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).

1980-05-31

439

Radiation modification of vascular prostheses  

International Nuclear Information System (INIS)

The radiation method has been employed for the modification of the surface of vascular prostheses by means of acrylamide. As a result of the treatment, the tightness of the prosthesis walls was improved as well as an increase of surface hydrophilicity. Upon autoclaving, stable binding of polyacrylamide to prostheses is achieved. (author).

440

Radiation inactivation target size of rat adipocyte glucose transporters in the plasma membrane and intracellular pools  

Energy Technology Data Exchange (ETDEWEB)

The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and 109,000 daltons prior ...

1987-06-15

441

Radiation decontamination of dry food ingredients and processing aids  

International Nuclear Information System (INIS)

Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be ...

442

Prevention and treatment of functional and structural radiation injury in the rat heart by pentoxifylline and alpha-tocopherol  

UK PubMed Central (United Kingdom)

PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available

2008-09-01

443

Photosynthetic Response of Seagrasses to Ultraviolet-A Radiation and the Influence of Visible Light Intensity 1  

UK PubMed Central (United Kingdom)

Inhibition of photosynthesis by ultraviolet-A radiation (UV-A, 315-380 nanometers) was examined in three marine angiosperms: Halophila engelmannii Aschers, Halodule wrightii...Full Text Available

1982-02-01

444

Parallel Evolution of a Type IV Secretion System in Radiating Lineages of the Host-Restricted Bacterial Pathogen Bartonella  

UK PubMed Central (United Kingdom)

Adaptive radiation is the rapid origination of multiple species from a single ancestor as the result of concurrent adaptation to disparate environments. This fundamental evolutionary process is considered...Full Text Available

2011-02-01

445

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

446

Investigation of the radiological safety concerns and medical history of the late Joseph T. Harding, former employee of the Paducah Gaseous Diffusion Plant  

Energy Technology Data Exchange (ETDEWEB)

An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.

1981-03-01

447

Inhibited spontaneous emission by a Rydberg atom  

Science.gov (United States)

Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.

1985-11-11

448

Induction of tumors by screening mammography  

International Nuclear Information System (INIS)

Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.

1983-01-01

449

Image-based modeling of tumor shrinkage in head and neck radiation therapy1  

UK PubMed Central (United Kingdom)

Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available

2010-05-01

450

Further assessment of the effects of occupational radiation exposure in the United Kingdom Atomic Energy Authority mortality study.  

UK PubMed Central (United Kingdom)

The United Kingdom Atomic Energy Authority mortality study was designed to investigate the relation between exposure to ionising radiation and mortality among the authority's employees. The present...Full Text Available

1987-03-01

451

Fragment condensation of peptides on teflon with radiationally grafted polystyrene  

Energy Technology Data Exchange (ETDEWEB)

In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the ..beta.. chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.

1986-12-10

452

Fragment condensation of peptides on teflon with radiationally grafted polystyrene  

International Nuclear Information System (INIS)

In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the #beta# chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.

453

Flashlamp radiation recycling for enhanced pumping efficiency and reduced thermal load  

Energy Technology Data Exchange (ETDEWEB)

A method for recycling laser flashlamp radiation in selected wavelength ranges to decrease thermal loading of the solid state laser matrix while substantially maintaining the pumping efficiency of the flashlamp.

1989-01-01

454

Epidemiological survey of the effects of low level radiation dose: a comparative assessment  

Energy Technology Data Exchange (ETDEWEB)

This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

1993-10-01

455

Electron spin resonance studies of radiation effects in biological materials. An assessment of current and future research  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance spectroscopy can provide a powerful approach to the study of radiation effects in biological materials. This memorandum gives an overview of current and future research. (author).

1987-06-01

456

Effects of small doses of ionizing radiation on human health  

Energy Technology Data Exchange (ETDEWEB)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-12-01

457

Effects of small doses of ionizing radiation on human health  

International Nuclear Information System (INIS)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-01-01

458

EPR dosimetry in chemically treated fingernails  

UK PubMed Central (United Kingdom)

By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available

2007-08-01

459

Differential Gene Expression in Primary Human Skin Keratinocytes and Fibroblasts in Response to Ionizing Radiation  

UK PubMed Central (United Kingdom)

Although skin is usually exposed during human exposures to ionizing radiation, there have been no thorough examinations of the transcriptional response of skin fibroblasts and keratinocytes...Full Text Available

2009-07-01

460

Current Role and Future Perspectives of Magnetic Resonance Spectroscopy in Radiation Oncology for Prostate Cancer  

UK PubMed Central (United Kingdom)

Prostatic neoplasms are not uniformly distributed within the prostate volume. With recent developments in three-dimensional intensity-modulated and imageguided radiation therapy, it is possible to treat...Full Text Available

2007-06-01

461

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs and Single Arc  

UK PubMed Central (United Kingdom)

PurposeA dosimetric comparison between multiple static-field intensity-modulated radiation therapy (IMRT), multi-arc intensity-modulated arc therapy (IMAT) and single-arc...Full Text Available

2010-04-01

462

Cellular Senescence, Radiation Damage to Mitochondria, and the Compensatory Response in Ripening Pear Fruits 1  

UK PubMed Central (United Kingdom)

A compensatory response, viz. in vivo recovery from radiation damage to mitochondria, occurs in preclimacteric pear fruits (Pyrus communis L.) treated with ionizing...Full Text Available

1968-07-01

463

CRC handbook of management of radiation protection programs  

Energy Technology Data Exchange (ETDEWEB)

This guidebook organizes the profusion of rules and regulations surrounding radiation protection into a single-volume reference. Employee and public protection, accident prevention, and emergency preparedness are included in this comprehensive coverage. Whenever possible, information is presented in convenient checklists, tables, or outlines that enable you to locate information quickly.

1986-01-01

464

Annealing behavior of radiation damages in metal-silicides  

International Nuclear Information System (INIS)

The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).

465

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on sensitivity of flaw ...

1998-02-01

466

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

467

5 - NASA Technical Reports Server  

Science.gov (United States)

The mission includes a reflected solar instrument retrieving at-sensor .... incoming solar radiation. This direct aerosol radiative forcing (DARF) ... examining the behavior of geosynchronous rocket bodies and non-stabilized payloads as ...

468

20th century and radiation accidents; O seculo XX e os acidentes nucleares  

Energy Technology Data Exchange (ETDEWEB)

The chapter presents the nuclear energy development in 20th century and the most important radiation accidents happened from the point of view of technological risk and high impact consequences: Three Mile Island and Chernobyl.

2006-07-01

469

USSR Report, Electronics and Electrical Engineering.  

Science.gov (United States)

... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...

1985-04-30

471

Survey of radiation protection programmes for transport; Etude des programmes de radioprotection pour les transports de matieres radioactives  

Energy Technology Data Exchange (ETDEWEB)

The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)

2001-07-01

472

Spontaneous radiation of an electron beam in a free-electron laser with a quadrupole wiggler  

Energy Technology Data Exchange (ETDEWEB)

A calculation is presented of spontaneous radiation emitted by an electron beam passing through a continuously rotating quadrupole magnetic undulator. It is shown that radiation spectrum emitted in forward direction of beam propagation has four peaks, corresponding to four betatron frequencies. Utilizing the Madey theorem, a stimulated emission is calculated and presented as gain versus frequency curves, for different values of the quadrupole magnetic field. A free-electron laser operating at two or three radiation frequencies with a quadrupole magnetic wiggler is suggested.

1986-09-01

473

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

474

Relaxation oscillation of amplified spontaneous radiation pulse emitted from a single-mirror Cu/CuBr laser  

Energy Technology Data Exchange (ETDEWEB)

The relaxation oscillation of the amplified spontaneous radiation pulses emitted from a single-mirror Cu/CuBr laser has been observed for the first time and the experimental characteristics of the relaxation oscillation were obtained. In addition, the spatial and temporal distributions of the light pulse intensity of the amplified spontaneous radiation were also measured and found to be comparatively and uniform. The spatial coherence of the amplified spontaneous radiation was found to be better than that of the laser with the same lasant.

1985-10-01

475

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

476

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

478

Problems involved in developing an index of harm  

International Nuclear Information System (INIS)

Death as a criterion (age distribution of occupational death; mean loss of life years due to radiation deaths); accidents at work (incidence of accidents of certain degrees of severity); total loss of working days due to accidents; occupational diseases; somatic and genetic radiation effects; radiation effects during pregnancy (incidence of pregnancies, ristes before implantation, hazards to the embryo, hazards to the foetus, total additional risk due to radiation exposure during pregnancy); age and sex dependence of risk figures; attempted formulation of an index of harm. (HP/orig.).

1979-01-01

479

Power Beaming, Orbital Debris Removal, and Other Space ...  

Science.gov (United States)

... transition to couple the emitted spontaneous radiation with the ammonia molecules and thus provide more amplification [2]. ...

2010-03-01

480

Non-gravitational perturbations and satellite geodesy  

Energy Technology Data Exchange (ETDEWEB)

This book presents the basic ideas of the physics of non-gravitational perturbations and the mathematics required to compute their orbital effects. It conveys the relevance of the different problems that must be solved to achieve a given level of accuracy in orbit determination and in recovery of geophysically significant parameters. Selected Contents are: Orders of Magnitude of the Perturbing Forces, Tides and Apparent Forces, Tools from Celestial Mechanics, Solar Radiation Pressure-Direct Effects: Satellite-Solar Radiation Interaction, Long-Term Effects on Semi-Major Axis, Radiation Pressure-Indirect Effects: Earth-Reflected Radiation Pressure, Anisotropic Thermal Emission, Drag: Orbital Perturbations by a Drag-Like Force, and Charged Particle Drag.

1987-01-01

481

N86-28427  

Science.gov (United States)

SPONTANEOUS RADIATION EMITTED BY MOVING TETHERED SYSTEMS. M. Dobrowolny. Istituto Fislca Spazio Interplanetario, CNR Italy ...

482

Ionizing radiation hardening procedure of CCD's  

International Nuclear Information System (INIS)

The procedure of charge-coupled devices (CCD) are investigated by using MOS capacitors for enhancing their ionizing radiation tolerance. Authors have found that the gate oxidation temperature, thickness of SiO_2 gate insulator and high temperature processes after gate oxidation are crucial for determining the radiation tolerance of the devices, and proposed to decrease the thickness of gate insulator, perform gate oxidation at 1000 deg C by means of dry oxidation and minimize the number of high temperature procedure steps after gate oxidation. All stated above is a necessary preparation for priducing radiation hardened charge-coupled devices.

483

Intraband Absorptoin of Far-Infrared Light by Electrons in ...  

Science.gov (United States)

... significant change of spontaneous radiation intensity. It is very sensitive technique allowing the observation of small changes of light absorption. ...

1999-06-18

484

International trends in radiation protection  

International Nuclear Information System (INIS)

The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.

485

INTERACTIONS OF COHERENT OPTICAL RADIATION WITH ...  

Science.gov (United States)

... and flashtube. Unfortunately, we had insufficient laser intensity to use the harmonic from a KDP crystal as a monitor. This ...

1964-08-31

486

Helium atom doping of molybdenum and its influence on the radiation hardenings  

International Nuclear Information System (INIS)

Experimental results on study of helium concentration influence on degree of molybdenum radiation hardening for various method of cyclotron doping differing in degree and damage character are presented. It is established that accumulation of helium atoms in molybdenum for simultaneous formation of radiation defects caused by low energetic primary-knocked atoms leads to higher degree of hardening than for high energetic ion irradiation. It is shown that with increase of helium atom concentration the degree of radiation hardening for the same level of damage increases. 4 refs.; 3 figs. (author).

1990-05-22

487

Growth, Characterization and Device Development in ...  

Science.gov (United States)

... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...

1998-03-01

488

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

489

Emission of photons by electrons and positrons passing through a thin single crystal  

Energy Technology Data Exchange (ETDEWEB)

We consider the radiation of particles (electrons and positrons) undergoing planar channeling in a single crystal of small thickness L. We show that for Lapprox...pi..b/theta/sub L/, where b is the lattice constant and theta/sub L/ is the Lindhard angle, in addition to the principal maxima of spontaneous radiation of channeled particles in the spectrum there are additional interference maxima, and the positions of all maxima of the radiation intensity depend on L. We discuss the dependence of the intensity of radiation at various frequencies on the crystal thickness.

1984-07-01

491

Electroluminescence Study of Green Be-Contained II-VI ...  

Science.gov (United States)

... laser structure. However, still the greater part (60%) of emitted photons is a result of a spontaneous radiation process. In ...

2000-06-23

492

Effect of Radiation Exposure on the Retention of Commercial NAND Flash Memory  

Science.gov (United States)

We have compared the data retention of irradiated commercial NAND flash memories with that of

2011-01-01

493

Distributed-processing radiation management system for nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The importance of radiation management for nuclear facilities including nuclear power plants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear power plants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributed-processing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)

1999-06-01

496

222Rn exhalation rate from Egyptian building materials using active and passive methods  

International Nuclear Information System (INIS)

... Sciences, Research Center for Radiation Protection, Chiba (Japan) Hafez,

2009-03-01

497

"2"0"3Pb yields while irradiating thallium with protons and deuterons  

International Nuclear Information System (INIS)

... data deuteron beams energy dependence errors gamma radiation lead 203