A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiationhardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiationhardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is ...
We report on measurements of radiationhardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiationhardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 ...
... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...
Hard Nano-Strutural Coatings Resistant to the Extreme Conditions of Chemical, Abrasive and High Energy Media for Thermonuclear Power, Oil and Gas and Chemical Industries
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...
We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...
A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between ...
Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).
This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ...
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiationhardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiationhardness specifications, dose rates, process control with respect to ...
An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.
Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.
The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiationhardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented.
High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.
Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much ...
Total-dose irradiation seriously damages MOS devices and their circuit performance. Threshold voltage shifts, transconductance degradation and increase in off-state leakage current are generally observed for irradiated devices. These instabilities are essentially due to positive and/or negative charge trapping in SiO_2 and interface trap generation at the SiO_2/Si interface. Radiation hardening of CMOS VLSIs is to eliminate these trapping effects, and for this purpose, special considerations for fabrication processes and layout design are necessary. In this paper, basic mechanisms for radiation-induced charge trapping and related effects on MOS devices are reviewed. Also discussed are radiation-hardening technologies from both fabrication-process and layout-design viewpoints. Using these technologies, 1 #mu#m radiation-hard CMOS gate arrays have been successfully developed. Experimental data taken for ...
Investigations of superdense compression touch on such problems as ultrahigh-frequency oscillations of matter in the generation of gravitational waves, the powerful pumping of hard coherent radiation, and the laboratory simulation of stellar interiors. This paper reviews the theory of supercompression and discusses some experiments involving multifoil collision supercompression.
The influence of additionally injected short-wavelength photobleaching light on the radiationhardness of Ge-doped graded index fibers working at 1,300 nm wavelength is investigated. Predictions are complicated by the fact that more efficient shortwave bleaching light experiences higher radiation-induced loss. Promising results are found for low fiber temperatures (approx-lt -50 C) and bleaching light of about 835 nm wavelength.
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiationhardness, gamma-ray background insensitivity, and large signal output.
Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...
The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiationhardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiationhardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...
X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).
Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Effect of radiation dose and carbon nanotubes (CNT) on the mechanical properties of standard Malaysian rubber (SMR) was investigated in this study. SMR nanocomposites containing 1-7 phr CNT were prepared using the solvent casting method and the nanocomposites were radiated at doses of 50-200 kGy. The change in mechanical properties, especially, tensile strength (Ts), elongation at break (Eb), hardness and tensile modulus at 100% elongation (M{sub 100}) were studied as a function of radiation dose. The structure and morphology of reinforced natural rubber was investigated by FESEM, TEM and AFM in order to gain further evidence on the radiation-induced crosslinking. It was found that the Ts, M{sub 100} and the hardness of the SMR/CNT nanocomposites significantly increased with radiation dose; the elongation at break exhibited an increase up to ...
A program was undertaken to radiation harden an existing power integrated circuit technology (BCDMOS) to total dose, gamma dot, SEU, and neutrons. Efforts have centered around hardening and optimizing our CMOS, DMOS, and NPN devices. Initial results indicate a substantial improvement in hardness over our existing commercial technology.
The influence of RTA (Rapid Thermal Anneal) treatment on MOS radiationhardness is demonstrated and compared with classical furnace treatment. In the case of the RTA, the oxide trapped charge is found to depend on: (i) the anneal temperature as expected, data are in good agreement with a recently developed model of oxygen out-diffusion; (ii) the location across the wafer with a radial dependence, results could be related to stress induced by thermal gradient.
Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after ...
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...
This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.
TNF-doped Mylar is a new radiation-hard dielectric that has recently been qualified as a viable substitute for Mylar in capacitors. The advantage of TNF-doped Mylar is that it satisfies both the nuclear safety and radiationhardness requirements of weapons. Mylar is not radiation-hard. Aging and compatibility studies were carried out to insure that (1) TNF does not diffuse from the film during fabrication of the capacitor or during storage; and (2) there are no compatibility problems with aluminum foil (the conductor) or Fluorinert (the secondary dielectric). Losses of TNF were barely detectable during the vacuum bakes used in fabricating capacitors or during accelerated aging tests carried out below T{sub g} (70C) over a two year period in air. In other accelerated tests, no compatibility problems were detected with aluminum or Fluorinert. TNF-doped Mylar is now being used in the MC-4109 capacitor that ...
Silicon sensors have about ten times improved radiationhardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in ...
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of polarized ...
On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.
Radiation induced polymerization of methylmethacrylate and copolymerization of styrene-acrylonitrile mixture in mamrase Carpinus betulus was carried out by means of #gamma#-ray, under different moisture levels and additives. Under all conditions the degree of polymerization was as high as 60%. No pronounced differences were observed in the kinetics of the polymerization of MMA either with moisture content of wood nor with kind and amount of additives. At high moisture (80% RH) content the dimensional stability of wood-PMMA was increased four fold as compared with untreated wood. The hardness increased about 100% for a weight conversion of monomer of about 30 to 40%. Hardness of this wood-polymer composite is comparable to that of the best noble woods in the world. (author).
Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of oxygen. Increasing the irradiation dose leads to an enhancement of the compression strength of the pure ...
The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of wood composite ...
The RD50 collaboration has been exploring the development of radiationhard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
The RD50 collaboration has been exploring the development of radiationhard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
This research report discusses the radiation hardening of a commercially available mobile robot, the REMOTEC ANDROS. This hardening effort is culminating in the availability of a megarad hardened mobile platform to access areas in nuclear facilities with extremely high levels of radiation (0.1 to 1 Mrad). These radiation levels may be encountered both during routine repair and monitoring activities and accident situations. The project has completed a phase-I U.S. Department of Energy Small Business Innovative Research contract and is now in a phase-II effort with completion scheduled in early 1995. The research involves the evaluation of the material and electrical components of an ANDROS robot to determine the anticipated radiationhardness of the current production version and evaluation of the components that must be replaced or modified to harden the system to higher ...
We monitored PSR B0329+54 for one year using the Nanshan 25-m radio telescope, the scintillation velocity V ISS shows evidence of systematic variation with the day of the year. States of interstellar medium (ISM) are discussed.
The properties of wood plastic composites (WPC) based on Pinus Radiata D. Don impregnated with methylmethacrylate and subsequently polymerized with gamma radiation were studied. Different systems of impregnation were utilized, in order to obtain partial and shell loads. The minimum irradiation dose uses was 16 kGy. The following tests were made to the material: static bending, compression strenght parallel to grain, hardness, sheer strength, toughness, water absorption, dimensional stability and flame propagation index. To evaluate the testing, the results of the samples were separated according final density in the ranges: R_1 = 429-483 kg/m3 (without treatment); R_2 = 500-650 kg/m3 and R3 = 651-850 kg/m3. In general, the best results were obtained for samples of high density. The most important results were achieved for dimensional stability, water absorption and hardness. (Author).
The first essential before embarking on the radiation-hardening of electrical insulation - mostly magnet coils - in any beam line application is to obtain a reliable estimate of the dose to the components. These are examples ( switchyards at SLAC and LAMPF) where the degree of hardness specified was much higher than was required. Although experience shows that the cost premium for substantial radiation - hardening is of the order of 10%, it has also become clear that well - designed beam line have negligible losses: hardening is required only in the vicinity of targets, collimators or other beam - intercepting devices. Where the beam is deliberately scraped, local shielding will minimize the associated radiation in the surroundings. Electron machines have their own special problems due to synchrotron radiation, so certainly coils and other electrical equipment should be kept away ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...
The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).
It has been prepared composites materials by means of monomer penetration in pores of wood samples and later curing by means of gamma irradiation. The studied species were Hura crepitans L. (catahua), Aniba puchury-minor (C. Martinez) (mohena amarilla), and Calycophyllum spruceanum (Benth.) (capirona). These new materials exhibit smaller water absorption and better mechanical properties in comparison with native wood. The test tubes of catahua treated with the styrene-polyester mixture absorb only up to 10% humidity compared to the native species whereas its hardness is increased in a 100%. (author).
Some results on mechanical property study of copper and titanium subjected to impact load and next to neutron irradiation are presented. It was shown that shock wave influence involves a substantial shape change of the stress-strain diagram and of respective mechanical characteristics. Yield- and ultimate strength were substantially increased, as well as hardness with a considerable drop of plasticity. Also a heat stability of copper and titanium specimens was studied after being treated with shock-waves and neutron radiation. Results are given of electron microscope study of titanium structure sfter explosion hardening, which caused decomposition of hydride segregations in titanium and increased dislocation density.
Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.
Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of irradiated specimens were studied using transmission electron microscopy (TEM) and a ...
Bent specimens of A533B steel (0.16wt% Cu) were irradiated at 290degreeC to 1dpa with 6.4MeV Fe3+ ions. Calculated tensile stresses at the irradiated surface were set to 0, 250, 500 and 750MPa. The specimens were subjected to hardness measurements, transmission electron microscopy (TEM) observations and three-dimensional atom probe (3DAP) analysis. The radiation-induced hardening decreased with increasing stress to 500MPa which was near the yield strength. TEM and 3DAP results showed that well-defined dislocation loops and solute clusters were formed. The diameter of dislocation loops increased and the number density decreased when the stress was applied, whereas the diameter and number density of solute clusters decreased. The hardening was mainly attributed to solute cluster formation. A...
A radiationhard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study.
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the ...
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons and gamma rays are resolved in both time ...
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...
Tritium occurs in nature in trace amounts, but its concentration is changing due to natural and artificial sources. Studies focusing on natural tritium have to take into account the effect of artificial sources. Also, the impact of tritium is an important issue in environmental protection, e.g. in connection with the emissions from nuclear power plants. The present work focuses on the rain washout of tritium emitted from the Paks nuclear power plant in Hungary. Rainwater collectors were placed around the plant and after a period of precipitation, rainwater was collected and analysed for tritium content. Samples were analysed using low-level liquid scintillation counting, with some also subject to the more accurate "3He ingrowth method. The results clearly show the trace of the tritium plume emitted from the plant; however, values are only about one order of magnitude higher than environmental background levels. A washout model was devised to estimate the ...
Post-irradiation annealing was used to help identify the role of radiation-induced segregation (RIS) in irradiation-assisted stress corrosion cracking (IASCC) by preferentially removing dislocation loop damage from proton-irradiated austenitic stainless steels while leaving the RIS of major and minor alloying elements largely unchanged. The goal of this study is to better understand the underlying mechanisms of IASCC. Simulations of post-irradiation annealing of RIS and dislocation loop microstructure predicted that dislocation loops would be removed preferentially over RIS due to both thermodynamic and kinetic considerations. To verify the simulation predictions, a series of post-irradiation annealing experiments were performed. Both a high purity 304L (HP-304L) and a commercial purity 304 (CP-304) stainless steel alloy were irradiated with 3.2 MeV protons at 360 deg. C to doses of 1.0 and 2.5 dpa. Following irradiation, post-irradiation anneals were performed at ...
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 A/cm"2 (R/min); the ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a ...
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes ...
We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p {yields} ne{sup +} ...
Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).
The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.
The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.
In the Peruvian natural forest there are several kind of woods, some of those are not of commercial interest, because have not resistance at termites and wet, are too soft, or can not be well finished, in the others. The present work is devoted to improvement of the physical properties of wood, such as hardness, traction, wet resistance, etc., by means of the generation of a composite wood-polymers cured by using gamma irradiation. The main objective is to establish the main parameters for the polymerization process (economic technical aspect) that decrease the amount of water absorption, in consequence the volumetric variation of Catahua, Mohena and Capirona woods. Gamma irradiation also provides good protection against the biological agents. In consequence, these woods increase its intrinsic and economic values. (author)
Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiationhardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.
We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.
The condition for obtaining a calorimetric response linear with energy for hadronic showers and an energy resolution that improves as the incident energy increases is the equalization of the electromagnetic (e) and the hadronic (#pi#) signal responses. This equalization is obtained by exploiting a local hardening effect realized through the insertion of low-Z thin plates between the high-Z absorbers and the active material in a hadronic calorimeter with silicon readout. This effect, which allows the reduction of the calorimeter response to the electromagnetic component of the incoming hadronic showers, has been investigated for different low-Z materials. The relevance of some aspects of this study to the radiationhardness of the calorimeters is also addressed. (orig.).
We consider the evolution of binary systems formed by a Supermassive Black Hole (SMBH) residing in the center of a galaxy or a globular cluster and a star in its immediate vicinity. The star is assumed to fill its Roche lobe, and the SMBH accretes primarily the matter of this star. The evolution of such a system is mainly determined by the same processes as for an ordinary binary. The main differences are that the donor star is irradiated by hardradiation emitted during accretion onto the SMBH; in a detached system, nearly all the donor wind is captured by the black hole, which strongly affects the evolution of the semi-major axis; it is not possible for companions of the most massive SMBHs to fill their Roche lobes, since the corresponding orbital separations are smaller than the radius ...
The determination of residual stress (RS) in case-hardened steel gear truck synchronisers coated with thermal sprayed molybdenum was carried out using neutron and synchrotron X-ray diffraction. Two samples with different coating thicknesses (about 120 ?m and 1.4 mm) and different steel substrates (16MnCr5 and SAE4140, respectively) were investigated. Microanalysis revealed substantial porosity in both samples and some debonding was observed between the thin coating and the substrate. The bulk hardness of the SAE 4140 proved to be much higher than the 16MnCr5 and the surface case-hardening increased it by a further 20%. The full three-dimensional stress depth-profile was determined by neutron diffraction (ND) in both the coatings and the substrates, while synchrotron radiation allowed a dep...
Effect of helium and hydrogen production on radiation-hardening of F82H irradiated by dual or triple beam condition were investigated. The specimens used were four types of ferritic martensitic steels of F82H-std (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) steels tempered at 750degC for 60 minutes, 20% cold worked F82H steel, F82H tempered for 10 minutes and non-tempered F82H steels. The irradiation was performed at 450degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The ratios of He (appm)/dpa and H(appm)/dpa were 15 nad 15 (or 150) for dual and triple ion beams. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. The hardness in these F82H steels irradiated at 450degC to 18 dpa under triple beam irradiation was harder than that under dual beam irradiation. Irradiation softening and hardening ...
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. ...
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined ...
Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency
A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.
To simulate radiation damage under a future Spallation Neutron Source (SNS) environment, irradiation experiments were conducted on a candidate 9Cr-2WVTa ferritic/martensitic steel using the Triple Ion Facility (TIF) at ORNL. Irradiation was conducted in single, dual, and triple ion beam modes using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} at 80, 200, and 350{degrees}C. These irradiations produced various defects comprising black dots, dislocation loops, line dislocations, and gas bubbles, which led to hardening. The largest increase in hardness, over 63 %, was observed after 50 dpa for triple beam irradiation conditions, revealing that both He and H are augmenting the hardening. Hardness increased less than 30 % after 30 dpa at 200{degrees}C by triple beams, compatible with neutron irradiation data from previous work which showed about a 30 % increase in yield strength after 27.2 dpa at 365{degrees}C. ...
We irradiated proton beams on the ears of rabbits and the Harding-Passey mouse melanoma and observed their morphological change. We used 52 MeV proton beams from the INS-FM cyclotron. We adjusted the energy of the proton beams to be at the plateau part of the Bragg curve, at the half-way point of the Bragg peak, and at the Bragg peak. The amount of radiation was 5000rad in each case. The Harding-Passey mouse melanoma was transplanted into the subcutan of a three week old mouse. In this experiment, we used tumors, the diameter of which grew up to 1.5-2cm in 2-3 weeks after the transplantation. Using the jroscope, we observed both lightly and severely damaged cells. Using proton irradiation with the Bragg peak located at depth of 1mm in the rabbit's ears, we studied the change in the tissue. Irradiated epidermis fell off and was eroded because of radiation damage, but the rear surface of the ...
The fatigue and fracture behavior of hard tissues are topics of considerable interest today. This special group of organic materials comprises the highly mineralized and load-bearing tissues...Full Text Available
Radiowave scintillation in the presence of ionospheric disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report describes development of a model characterizing the plasma density irregularities that produce scintillation in the naturally disturbed mid-latitude F layer. The model will be incorporated into Program WBMOD, which includes subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. Earlier versions of WBMOD, were based on extensive analysis of scintillation data collected in the auroral and equatorial zones in Wideband Satellite Mission. The model described herein is based on similarly extensive analysis of Wideband data from one mid latitude station and of data collected from HiLat satellite at another mid latitude station. The model describes irregularities at an effective ...
Lithium carbonate pellets are frequently used for estimation of tritium production rate in irradiated samples in fusion blanket neutronics experiment and the activity is measured by liquid scintillation counting technique. In this measurement, it is essential to solve the lithium carbonate pellet as much as possible and to mix the pellet solution into scintillation cocktail homogeneously at stable condition. For this purpose, a novel binary-acid method has been developed to solve lithium carbonate and to mix the pellet solution into scintillation cocktail. High solubility is attained by adopting two acids, HNO_3 and CH_3COOH, and a good compatibility of the pellet solution with scintillator is obtained by emulsion cocktail resulting in high counting efficiency. Defining a product of dissolved mass and counting efficiency as a Figure of Merit (FOM), the present method has higher FOM value than the ...
Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron energies were determined by time-of-flight techniques with ...
The Fermi National Laboratory (Fermilab) operates the Tevatron proton-antiproton collider at a center-of-mass energy of {radical}s = 1.96 TeV, the is therefore the only collider which is today able to produce the heaviest known particle, the top quark. The top quark was discovered at the Tevatron by the CDF and D0 collaborations in 1995. At the Tevatron, most top quarks are produced via the strong interaction, whereby quark-antiquark annihilation dominates with 85%, and gluon fusion contributes with 15%. Considering next-to-leading order (NLO) contributions in the cross section of top-antitop quark production, leads to a slight positive asymmetry in the differential distribution of the production angle {alpha} of the top quarks. This asymmetry is due to the interference of certain NLO contributions. The charge asymmetry A in the cosine of {alpha} is predicted [14] to amount to 4-6%. Information about the partonic rest frame, necessary for a measurement of A in the observable cos ...
For several decades most of the efforts to develop new scintillator materials have concentrated on high-light-yield inorganic single-crystals while polycrystalline ceramic scintillators, since their inception in the early 1980 s, have received relatively little attention. Nevertheless, transparent ceramics offer a promising approach to the fabrication of relatively inexpensive scintillators via a simple mechanical compaction and annealing process that eliminates single-crystal growth. Until recently, commonly accepted concepts restricted the polycrystalline ceramic approach to materials exhibiting a cubic crystal structure. Here, we report our results on the development of two novel ceramic scintillators based on the non-cubic crystalline materials: Lu SiO:Ce (LSO:Ce) and LaBr:Ce. While no evidence for texturing has been found in their ceramic microstructures, our LSO:Ce ceramics exhibit a surprisingly ...
An analysis was perfonned on the mid-latitude scintillation and coherence frequency bandwidth (Fcoh) using transionospheric VHF signal data. The data include 1062 events spanning from November 1997 to June 2002. Each event records FORTE satellite received VHF signals from LAPP located at Los Alamos, New Mexico. Fcohs were derived to study scintillation characteristics on diurnal and seasonal variations, as well as changes due to solar and geomagnetic activities. Comparisons to the VHFIUHF coherence frequency bandwidth studies previously reported at equatorial and mid-latitude regions are made using a 4th power frequency dependence relationship. Furthennore, a wideband ionospheric scintillation model, WBMOD, was used to estimate Fcohs and compared with our VHF Fcoh values. Our analysis indicates mid-latitude scintillation characteristics that are not previously revealed. At the VHF bottom frequency range ...
Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alpha source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...
Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alphy source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...
Methylation of RNA by methyltransferases is a phylogenetically ubiquitous post-transcriptional modification that occurs most extensively in transfer RNA (tRNA) and ribosomal RNA (rRNA). Biochemical...Full Text Available
The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).
In this paper, the wavefunction of the universe with a tunneling boundary condition is considered in the context of the Brans-Dicke-type scalar-tensor theory with matter. The matter may be interpreted as a D-particle (or D0-brane) in string theory when the Brans-Dicke parameter {omega} is -1. We study two simple examples. The first example, the {gamma}=0 (matter) case, has a scale factor duality even if the low energy string action is coupled to matter. The universe undergoes quantum transition from super-inflationary (pre-big-bang) to deflationary (post-big-bang) phase. We calculate the transition rate by solving the Wheeler-DeWitt equation and find that it is non-vanishing. The two phases are disconnected classically. The second example is the {gamma}=1/3(radiation) case. With the help of earlier work this matter can be identified with a D0-brane in string theory. In this case, due to the absence of the scale factor duality and the complicated relations between ...
In this work a comprehensive metallophysical study was carried out for two aluminosilicide slip coatings of the systems Al-Si and Al-Nb-Si and an electron-beam Co-Cr-Al-Y coating on alloy EP-539 (17...19% Cr, 4...6% Co, 2.5...4% W, 4.5...6.5% Mo, 2...3% Ti, 3...4% Al, 1.4...2% Nb, balance Ni) after high-temperature testing. The protective properties of the coatings were evaluated from the results of laboratory tests for heat resistance at 1000/sup 0/C in the combustion products of diesel fuel with added sulfur at 970, 1000, and 1060/sup 0/C for 100 h and after full-scale tests for 150, 250, 400, and 700 h. Metallographic, hardness, x-ray, and micro x-ray studies of the coating were carried out. Layer-by-layer phase composition and the lattice spacing of the main phases were determined. X-ray analysis was carried out in an a DRON-1 diffractometer in copper K/sub ..-->../-radiation, and x-ray microanalysis was carried out in a MS-46 Cameca ...
Continuous metallic glass ribbons were produced by mejans of liquid-quenching at rates >10/sup 50/C/s. The ribbons, typically 30 ..mu..m thick and 1 to 2 mm wide, were determined to be glassy by X-ray diffraction (XRD) employing CuK..cap alpha.. and MoK..cap alpha.. radiation. Mechanical properties of the as-quenched product were determined by measurements of hardness, tensile strength and Young's modulus. The Vicker's diamond pyramid microhardness (H/sub V/) was measured on epoxy mounted samples using a Lietz Miniload instrument with a 100 g load. Tensile tests were conducted in an Instron machine using specimens which were hand-polished to produce smooth, parallel sides. Young's modulus (E) is given by the relationship rho V/sub E/sup 2//. V/sub E/, the velocity of extensional mode waves, was measured by the pulse-echo technique using a Panametrics Intervalometer and glass density, rho, was obtained by the liquid ...
For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe{sup +}, 360 keV He{sup +}, and 180 keV H{sup +} simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ductility (>20% ...
For an assessment of the future US spallation neutron source (SNS) target performance, radiation induced hardening and microstructural evolution were investigated as a function of ion dose for EC316LN stainless steel. Irradiation was carried out using 3.5 MeV Fe"+, 360 keV He"+, and 180 keV H"+ simultaneous ion-beams at 200 deg. C to simulate the damage, He and H production in the SNS target vessel wall. At low dose (< 1 dpa), the predominant defects were black dots whose number density saturated rapidly within a few dpa. This was followed by the evolution of interstitial loops whose number density saturated below 15 dpa. Although He-bubbles were not visible, severely scalloped loops suggested that the implanted He/H atoms existed in the form of small clusters. Comparison with reported neutron irradiation data showed that hardening and ductility loss occurred mostly in the black dot regime (< 1 dpa), but that good ductility (>20% elongation) was maintained ...
Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a reconstruction procedure similar to that used for electron microscopy. The combination of diffraction ('topography') and ...
The fading of irradiated and natural blue-colored pearls was investigated in this experiment. Thirty natural blue-colored pearls and sixty irradiated blue-colored pearls were used. Some of them were placed at a light position of RT. Another pearls were placed at a dark position of 50/sup 0/C. The irradiated pearls placed at a light position of RT didn't show remarkable fading in their color in 294 days. But the natural blue-colored pearls showed a little recovery from 4% to 8% in reflection factors in 223 days at RT. The irradiated pearls placed at a dark position of 50/sup 0/C showed the recovery from 9% to 14% in 264 days independently of irradiation times. The natural blue-colored pearls also showed the bleaching from 5% to 10% in reflection factor in 86 days at 50/sup 0/C. Both irradiated and natural blue-colored pearls hardly showed their remarkable changes in their chromaticities independently of temperatures.
The molar of guinea pigs was irradiated with /sup 60/Co-..gamma.. ray for daily observations of the manifestation of disturbed tooth formation by microradiography and the time registration by tetracycline-labelling. Irradiation first injured young blast cells of the dentin in the growth phase, dental pulp cells, and cells of the enamel. The portion composed of injured cells formed a depressed ''constriction'' from the dental pulp side toward the border between the enamel and dentin. The cells of the enamel injured by irradiation in the growth phase later formed a very thin irregular stroma. In contrast, cells in the differentiation or subsequent phase at the time of irradiation and cells probably having started to grow after irradiation proceeded with formation of a normal stroma and calcification. No uniform relation was obtained between the histological staining of the organic stroma of normal or abnormal dentin and calcification. Labelling with ...
Full text of publication follows: Fission neutron irradiation to steels doped with isotope boron-10 is frequently conducted to study effects of the helium production on mechanical properties. The intrinsic mechanical properties of F82H steels could have been changed due to the boron doping. Recently, we reported that co-doping with boron and nitrogen to F82H (F82H+B+N) improved the mechanical properties of F82H doped only with boron. The mechanical properties of F82H+B+N are successfully comparable with the non-doped F82H before irradiation. In order to evaluate the effects of initial microstructure and helium production on radiation hardening, F82H and F82H+B+N were irradiate d Specimens used in this study were standard F82H martensitic steels, F82H steels doped with 60 mass ppm 10B and 200 ppm N (F82H+10B+N) and F82H steels doped with 60 mass ppm 11B and 200 ppm N (F82H+11B+N). Initial microstructures were changed by tempering conditions, and the tempering ...
Single crystals of GdCl_3 doped with different concentrations of Ce"3"+ have been grown using the Bridgman-Stockbarger technique and their luminescence and scintillation properties were investigated. The luminescence spectrum of GdCl_3:Ce"3"+ is complex and consists of two bands with maxima at 350 nm and 370 nm. The maximal light yield in GdCl_3:Ce"3"+ was observed at #approx#1 mol% of Ce"3"+ (more than 38 000 ph/MeV).
LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.
A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))
BackgroundThe hard clam, Mercenaria mercenaria, has been affected by severe mortality episodes associated with the protistan parasite QPX (Quahog Parasite Unknown)...Full Text Available
Sep 1, 2011 ... Title: Hardness, density, and shrinkage characteristics of silk-oak from Hawaii. Author: Youngs, R. L.. Date: 1964. Source: Research note FPL ...
This report covers the test methods and equipment for testing aircraft armor both hard and soft. The hard armor are the typical ceramic type while the soft armor are various types of layered composite materials. 10 figs. (JEF)
The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...
Simulation irradiation experiments were carried out to investigate the formation processes and contribution to hardening of radiation-induced features in low alloy steels. Medium Cu (0.12 and 0.16%) and low Cu (0.03%) A533B steels were irradiated with 3 MeV Ni ions and 5 MeV electrons, and in KUR at 290degC. Irradiated steels were examined by three-dimensional atom probe, positron annihilation, high-resolution transmission electron microscopy and hardness measurements. Electron irradiation caused almost the same hardening as KUR irradiation in medium Cu steels under almost the same dose rate and dose conditions, whereas the formation of larger, denser and more Cu enriched clusters and smaller accumulation of single vacancies were confirmed for KUR irradiation. This indicated that cascade damage provides additional cluster nucleation sites to compensate for lower free point defect production. High dose rate Ni ion irradiation produced Mn-Ni-Si ...
Radiowave scintillation in the presence of natural and/or high-altitude nuclear disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report develops a model characterizing the plasma-density irregularities that produce scintillation in the naturally disturbed equatorial F layer. The model is incorporated into Program WBMOD along with subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. The model is based on similarly extensive analysis of wideband data from two equatorial stations. It describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field and elongated by a factor of 50 along the field and whose one-dimensional spatial power spectrum obeys a single-regime power law with a (negative) spectral index of 1.5. The height-integrated spectral strength of the ...
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of ...
The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy spectrometry with ...
Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.
Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth`s ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can he used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the third year of this project, which includes completion of the new model for the high-latitude (auroral and polar cap) region of the WBMOD model.
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities are operated and ...
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or ...
{sup 14}C is a is a long-lived beta-emitting nuclide (T{sub 1/2} = 5730 years) produced naturally in the upper atmosphere as a result of reactions between neutrons and stable {sup 14}N({sup 14}N(n,p){sup 14}C). Although in a lesser extent, nuclear power plants produce {sup 14}C as well during their routine operation. Since it is converted in {sup 14}CO{sub 2} and mixed throughout the atmosphere, it is incorporated into plant tissues, via photosynthesis process, and hence in food chain. Because of the biological importance of {sup 14}C and long half-life, it is of interest to quantify the amounts released by nuclear industry. The Brazilian nuclear central named Nuclear Central Admiral Alvaro Alberto (CNAAA) has two nuclear reactors of PWR type in operation, Angra I (657 MWe) and Angra II (1350 MWe), and one under construction, Angra III (1309 MWe PWR). The aim of this study was to determine the strength of the sources and the {sup 14}C content in the environment through analyses of air, ...
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
Research and development activities are reported on absorption spectroscopy, calorimetry, electrolysis, emission spectroscopy, fluorimetry gas chromatography, infrared spectroscopy, liquid chromatography, liquid scintillation counting, mass spectroscopy, microscopy, radiometric analysis, and thermal analysis. A group of miscellaneous projects are also described.
A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
Lead tungstate crystals doped with small fractions of praesodynium or molybdenum have been tested in beams of high-energy electrons. The goal of these tests was to study the effects of such dopants on the capability to separate the signal components deriving from the Cherenkov and scintillation light generated by the beam particles. These studies were carried out in view of the possible application of such crystals in dual-readout calorimeters.
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
A search for tachyons, or other particles detectable by G-M counter tubes or liquid scintillators, arriving during the approximately 100#mu#s immediately preceding extensive air showers (primary energy approximately 10"1"5 eV) has provided no positive evidence for the existence of such particles. (orig.).
A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.
The major details of the inspection and replacement of the bearing journals on each of the four heat transport pumps (HTPs) at Wolsung nuclear generating station in Korea are presented in this paper. Investigation following fracture of one of the journals in 1985 revealed that it was excessively hard. The journal material (ASTM A296 CA 40) is considered to be prone to stress corrosion fatigue if the hardness exceeds Rc 40. In 1986 May, during a planned outage, the HTPs were disassembled, the journals were inspected, found to be excessively hard, and all were replaced. At the same time, the pump to motor couplings were all refurbished to ensure proper alignment.
Hardness of beta-sialon with four different composition index values of 0.25, 0.50, 0.75 and 1.0 in the system Ni/sub 3/N/sub 4/-AlN-Al/sub 2/O/sub 3/ with the addition of 6% Y/sub 2/O/sub 3/ as sintering aid has been reported. These composition were pressureless sintered for 90, 180 and 270 min in nitrogen atmospheres at temperatures ranging from 1650 to 1800 deg. C. Highest hardness was achieved when the composition index was 0.25 was sintered for 270 minutes at 1750 deg. C. (author).
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
Apricot fruits usually harvested relatively mature but hard enough to withstand-post harvest handling through the marketing chain. These fruits have considerably lower edible quality than tree-ripened fruit. Fruit quality can be improved by delaying harvest least until physiological maturation is completed on the tree (Bonghi et al. 1999) Apricots containing 11% soluble solids concentration, or higher are in high demand by consumers, as fruit have developed considerable taste, aroma and handling for long distance markets. (Kader, 1999). These fruit will be highly perishable, so rapid cold storage to the lowest safe temperature and supplementary treatments (Mc Donald et al, 1999) such as irradiation with the recommend doses (Sillano et al, 1994) or pre-storage heat treatments will be necessary to retard ripening (mainly softening) during 1-2 weeks post harvest life necessary for distribution to distant markets (Mc Donald et al 1999). Therefore, one can conclude that ...
The boundary-integral equation method is well suited for the calculation of the dynamic-stiffness matrix of foundations embedded in a layered visco-elastic halfspace (or a transmitting boundary of arbitrary shape), which represents an unbounded domain. It also allows pile groups to be analyzed, taking pile-soil-pile interaction into account. The discretization of this boundary-element method is restricted to the structure-soil interface. All trial functions satisfy exactly the field equations and the radiation condition at infinity. In the indirect boundary-element method distributed source loads of initially unknown intensities act on a source line located in the excavated part of the soil and are determined such that the prescribed boundary conditions on the structure-soil interface are satisfied in an average sense. In the two-dimensional case the variables are expanded in a Fourier integral in the wave number domain, while in three dimensions, Fourier series in ...
... of Hanoi or Missionaries and Cannibals, It is not immediately obvious what constitutes a "move"--that is, what actual manipulations of the physical ...
Monolithic SiAlON ceramics are hard and brittle with little possibility for property design, but multi-phase SiAlON ceramics offer great scope for controlling microstructural development and desired properties. The ceramics can also be reinforced by separate additions of other hard, refractory compounds. The toughness in all these SiAlON composites can be increased by several mechanisms, and the best effect is reached if they are combined. When glassy phase is present, crack paths are affected by the strains caused by different thermal expansion of the glassy phase and the crystals and also by the interface properties. The crystal shape influence toughness, especially pronounced is the effect of the elongated #beta#- grains. Different toughening mechanisms are achieved by separately added reinforcement phases. The hardness is raised by the presence of #alpha# SiAlON and other hard constituents, such as ...
Counter-current regeneration of 2-stage sodium zeolite softeners has been employed in reducing hardness leakage level of steamflooding water to less than 1 ppm when raw water contains as much as 5,000 ppm of the total dissolved solids. Hardness leakage is caused by sodium displacement of calcium and magnesium from the bottom of the exchanger bed. This study presents nomographs providing for rapid calculations to be made, for which a convenient operational mode does not already exist. The nomographs relate the hardness leakage as a function of salt quality and influent water quality and present solutions for predicting the leakage level, salt quality requirement or the treatability of raw water required for steamflooding projects.
... interacting systems in which common-envelope evolutionary effects make it hard to generalize the results to single-star evolution, although they ...
BackgroundThe ongoing epidemiological transition in Mexico minimizes the relative impact of neurocysticercosis (NC) on public health. However, hard data on the disease frequency...Full Text Available
Necrotizing sialometaplasia, is a benign inflammatory lesion primarily involving the minor salivary glands of the hard palate. The lesion often presents itself as a deep-seated palatal ulcer with clinical...Full Text Available
Oct 30, 2009... of Belgian sheepherding dogs that are popular with the police and military. ... "She was a hard-working K-9 and she will be missed." ...
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
The average angle of repose and the packing density of random planar heaps of hard disks falling ballistically onto a sticky base line, where the first layer of disks is quenched in random positions, are computed for heaps with a small fixed number of gaps in the base layer. The results we find appear to be almost independent of the size of the heap and they agree with those obtained from computer simulations of large systems.
The structure and properties of composite powder coatings on the base of titanium carbide are studied. It is shown the electron-beam welding deposition of powders on the base of nickel and titanium carbide allows to produce of high-quality wear-resistant coatings which superior in density and hardness compared with sputtered ones. Changes of hardening phase volume percentage as well as composition of metal matrix make possible to control coatings hardness
We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical ...
We explore the relationship between the hard X-ray photon index $\\Gamma$ and the Eddington ratio (\\xi=L_{X}(0.5-25 keV)/L_{Edd}) in six XRBs. We find that different XRBs follow different anti-correlations between $\\Gamma$ and $\\xi$ when $\\xi$ is less than a critical value, while they follow the same positive correlation when $\\xi$ is larger than the critical value. This anti-correlation and positive correlation are also found in LLAGNs and QSOs respectively, and the anti-correlation and positive correlation of different XRBs roughly converge to the same point ($\\log \\xi=-2.1, \\Gamma=1.5$), which may correspond to the accretion mode transition, since that the anti-correlation and positive correlation are consistent with the prediction of ADAFs and standard disk/corona system respectively. The traditional low/hard state are divided into two parts by the cross point $\\log \\xi\\sim-2.1$, i.e., faint-hard state in the ...
Micro-Vickers hardness measurement has been used to determine the composition of functionally graded materials (FGMs). Materials used in the present study are Al-SiC, Al-Shirasu and Al-Al{sub 3}Ni FGMs, which are fabricated by a centrifugal method. The micro-hardness of the aluminum matrix for Al-SiC FGM markedly increases as the volume fraction of SiC particles increases. However, the tendency is not so clear in the cases of Al-Shirasu and Al-Al{sub 3}Ni FGMs. Plastic strain energy due to thermal misfits between the matrix and dipersed particles is calculated based on an elasto-plastic analysis by applying a shell theory after Lee et al. The hardness is correlated theoretically with the composition gradient through the mean plastic strain energy (responsible for dislocation density). It is concluded that the composition gradient of metal-based FGMs can be determined from micro-hardness measurements. ...
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a power law (with a photon index of 1.8), ...
We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of ...
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to dynamical fluid motion of ...
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine ...
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The detector is ...
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, involving short distances ...
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...
Passage of neon gas through activated charcoal is planned to be the primary method of removing impurities from the liquid neon scintillator in the CLEAN experiment. In order to quantify this technique, the breakout curves for hydrogen, nitrogen, argon and krypton impurities in neon-saturated activated charcoal were measured. Adsorption coefficients and the number of theoretical stages were measured for hydrogen in the temperature range between 300 and 80 K, nitrogen between 300 and 200 K, and argon between 300 and 190 K. The adsorption coefficient for krypton was measured at 300 K.
The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.
The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).
The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.
Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.
In order to investigate the systematics of the loop expansion in high temperature gauge theories beyond the leading order hard thermal loop (HTL) approximation, we calculate the two-loop electron proper self-energy #SIGMA# in high temperature QED. The two-loop bubble diagram of #SIGMA# contains a linear infrared divergence. Even if regulated with a nonzero photon mass M of order of the Debye mass, this infrared sensitivity implies that the two-loop self-energy contributes terms to the fermion dispersion relation that are comparable to or even larger than the next-to-leading order (NLO) contributions of the one-loop #SIGMA#. Additional evidence for the necessity of a systematic restructuring of the loop expansion comes from the explicit gauge-parameter dependence of the fermion damping rate at both one and two loops. The leading terms in the high temperature expansion of the two-loop self-energy for all topologies arise from an explicit ...
The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate for this case is ...
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
In the paper, the effect of Ni content, WC grain size and Mo2C addition on WC-6.25wt%TiC-9.3wt%Ni cemented carbide were investigated to improve the properties of Ni-bonded cemented carbides. The results show that the decrease of Ni content will result in the decrease of transverse rupture strength and increase of hardness; with the decrease of WC particle size, hardness increases due to the refinement of WC grains, however, the transverse rupture strength decrease due to the decrease of Ni binder thickness; Mo2C proves to be an effective grain growth inhibitor. With the increase of Mo2C content, the WC grains are refined and the hardness and transverse rupture strength are improved. Generally, when the Ni content is decreased to 8.4wt%, 13.45mm WC is used and 1.2wt% Mo2C is added, a higher...
A series of SiAlON materials with a cordierite-based matrix were annealed for different lengths of time to cause crystallization of the glass phase. Their fracture toughness, hardness, and elastic modulus were measured from room temperature up to 1100"0C. The fracture toughness generally decreased with temperature. Short time annealing raised toughness at lower temperatures, while further annealing lowered it back to the value for as-hot pressed materials. At higher test temperatures annealing had no effect on toughness. This annealing behavior is significantly different from that previously reported in the system SaAlON-YAG. Hardness decreased monotonically with temperature for all samples. Both hardness and the elastic modulus were not affected by the annealing treatment. At elevated temperatures appreciable scatter of modulus results allowed only a rough trend of decrease with temperature to be observed.
Molecular dynamics simulations have been carried out of the radial distribution function of the hard sphere fluid for a range of densities in the equilibrium fluid and just into the metastable region. The first derivative of the hard-sphere radial distribution function at contact was computed and its density dependence fitted to a simple analytic form. Comparisons were made with semi-empirical formulae from the literature, and of these the formula proposed by Tao et al (1992 Phys. Rev. A 46 8007) was found to be in best agreement with the simulation data, although it slightly underestimates the derivative at the higher packing fractions in excess of about 0.45. Close to contact, within a few per cent of the particle diameter, the radial distribution function can be represented well by a second order polynomial. An exponential function, which has some useful analytic features, can also be applied in this region.
PurposeThe purpose of this study was to determine the relationship between the changes of soft and hard tissues after modified anterior segmental osteotomy on the maxilla and mandible and to evaluate unintended facial changes using cephalometric and photometric analyses.Materials and MethodsThe subjects included 29 women and 1 man (22 to 50 years of age) who were diagnosed as bialveolar or bimaxillary protrusion and underwent modified anterior segmental osteotomy on the maxilla and mandible. Lateral cephalograms and lateral and frontal photographs taken preoperatively and postoperatively were analyzed.ResultsThere was a significant change in all soft and hard tissue parameters except the labiomental angle. The ratio of upper lip to maxillary incisor retraction was 0.67:1 and the ratio of l...
Dense samples of #beta#-sialons (with z from 1 to 4) were pressuressly sintered for different time (15-240 minutes) and at relatively low temperature of 1600 C using single-phase #beta#-sialon powders synthesized by combustion nitridation. The samples were characterized using ultrasonic method for determination of elastic properties (E,G,#mu#). Also, hardness by Knoop and fracture toughness by Vickers indentation microfracture method was estimated. With increasing z number Young's modulus decreases from 293 to 179 GPa. Simultaneously Poisson ratio increases by about 30%. The highest values of hardness and fracture toughness were obtained for sialon with z equal to 1. (orig.).
Leptonic pair production on nuclei ad EMC-effect are discussed within the frames of the flucton model with scaling distortion. Cumulative production of direct photons and leptonic pairs as a test of the model of hard collisions is considered. The results of calculations of massive leptonic pair production cross sections on nucleus fluctons, caculations of the ratio of deuterium and iron structural functions, cross sections of direct photon production on sup(181)Ta nuclei at Esub(p)=400 GeV and cross section of #pi#-meson production in the model of hard collisions are presented. Experimental discovery of direct cumulative photons is concluded to be important for understanding the mechanism of parton hard scattering from nucleus fluctons.
Ceramic ball bearings of silicon nitride are used for hard disk drive (HDD) spindle motors, to increase seed, reliability and memory capacity of the HDDs. Silicon nitride ceramics have advantages of lightweight, high strength and hardness over the conventional steel for bearings, but is expensive. A new process of high cost performance has been developed for mass production of the small-size ceramic balls. The company plans to apply these bearings to higher devices, e.g., servers, for the time being, and to expand the applicable areas, e.g., common devices and other small-size motors. The ceramic bearings have been developed jointly with Koyo Seiko Co. Ltd. (translated by NEDO)
Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.
Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...
... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
A stiff skin forms on surface areas of a flat polydimethylsiloxane (PDMS) upon exposure to focused ion beam (FIB) leading to ordered surface wrinkles. By controlling the FIB fluence and area of exposure...Full Text Available
These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...
ObjectiveTo implement a role-reversal exercise to increase first-year pharmacy students' awareness of communication barriers in the health care setting, especially for deaf and hard-of-hearing...Full Text Available
ObjectivesPericardial tamponade after cardiac surgery is difficult to diagnose, thereby rendering timing of rethoracotomy hard. We aimed at identifying factors predicting the outcome...Full Text Available
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
Plasma nitriding in glow discharge is a process of modifying surface properties of a material by which surface hardness, corrosion resistance, fatigue strength etc. of a material can be improved
BackgroundIn Trinidad and Tobago, the law on the mandatory use of seat belts was passed in 1995, but this law is hardly enforced. The objective of this study was to determine the...Full Text Available
This report discusses the following topics on superconductivity: nonlinearities in hard superconductors such as surface impedance of a type II superconductimg half space and harmonic generation and intermodulation due to alternating transport currents; and nonlinearities in superconducting weak links such as harmonic generation by a long Josephson Junction in a superconducting slab.
Ultra fine tungsten carbide and cobalt powders were milled by high energy planetary ball mill at different ball to powder weight ratios (BPR) to produce particles of WC-10wt%Co hard metal in nanometer scale size. Microstructural characterizations by TEM show that the particle size of tungsten carbide was achieved to 32nm after milling at 15 BPR during 10h. In order to reduce the WC grain growth during the sintering process, tantalum carbide was added to the hard metal as a WC grain growth inhibitor. The nano hard metal powders were compacted at 200MPa pressure and sintered at 1370-1450degreeC temperatures in a high purity hydrogen atmosphere. The results show that the addition of 0.6wt% of TaC improves the hardness and fracture toughness from 1493 HV30 and 11.8MPam (for TaC free sample) to...
Excimer laser processing enables both thermally-driven transformations and the incorporation of solutes into the surface of materials through melting and diffusional mixing. We have examined the effect of excimer laser processing on the microstructure and surface mechanical properties of titanium alloys. Changes in the surface hardness due to laser processing were studied using a Nanoindenter [trademark]. Alloying experiments using both mixing of evaporated surface layers of boron and laser gas alloying in air and in nitrogen all result in changes in the surface hardness of the material. Alloying with boron results in an amorphous surface which is somewhat harder than the as polished surface. Laser processing in air and pure nitrogen results in incorporation of oxygen and nitrogen and the development of fine ([approximately] 50 nm) precipitates of TiO and TiN respectively. Substantial increases in surface hardness result ...
Constraint-based lexical models of language processing assume that readers resolve temporary ambiguities by relying on a variety of cues, including particular knowledge of how verbs combine...Full Text Available
The October 2000 terrorist attack on the guided-missile destroyer USS Cole (DDG 67) in the port of Aden, Yemen, is commonly viewed in the larger context of al-Qa'ida's September 11th campaign. Beyond the initial official investigations, the military force...
The methods of surface modification of Ti-Zr alloy by laser treatment are considered. Characteristics of laser modification without- and with surface melting and with melting in different gaseous environments and with nickel microalloying are presented. Maximum depth, hardness and corrosion resistance are observed under nickel laser alloying.
Pressureless-sintered AlN and hot-pressed, pressureless-sintered and reaction-bonded SiC were neutron irradiated at temperatures between 100 and 785degC up to a fluence of 5.2 x 10"2"4 n/m"2. The hardness was increased by up to 51% in AlN and 84% in SiC. The hardness decreased after annealing at temperatures around the irradiation temperature. At the same temperatures, the macroscopic length, which was increased by irradiation, also began to decrease. The hardness and length were almost recovered after 1,200 #approx# 1,400degC annealing. Thus, hardening in irradiated AlN and SiC is controlled by the number of point defects, or, more precisely, by the strain caused by small point defect clusters which pin down dislocation movement. Dislocation loops were still observed in some samples after 1,400degC annealing while the hardness was almost recovered to that in the unirradiated state. Thus, the existence ...
BackgroundA goal of human genetics is to discover genetic factors that influence individuals' susceptibility to common diseases. Most common diseases are thought to result from the...Full Text Available
Plant surfaces covered with crystalline epicuticular waxes are known to be anti-adhesive, hardly wettable and preventing insect attachment. But there are insects that are capable of gluing their eggs...Full Text Available
68 replaced carbon steel piping in secondary system of pressurized water reactor (PWR) has been investigated by visual examination for checking thinning conditions. It is well known that the flow-accelerated corrosion (FAC) was inhibited by traces of Cr in steel. Therefore, the chemical compositions of those steels have been measured. In addition, the micro structure and hardness of those steels have been investigated. And the relationship between those material variables and FAC rate was considered. As the results, (1) The Cr contents in those steels were below 0.1 wt% except one sample. Minute quantities of chromium increase the resistance against FAC. But the water velocity was thought to be the dominant factor rather than chemical composition in steel, at least such as below 0.1%Cr. (2) Hardness of all piping has been satisfied the specifications of each materials. The hardness of steels was not correlated with wall ...
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
The adhesive proteins secreted by marine mussels form a natural glue that cures rapidly to form strong and durable bonds in aqueous environments. These mussel adhesive proteins contain an unusual...Full Text Available
Deposition of hard coatings may influence the mechanical properties of the bulk material and its corrosion resistance. In this work we study the hardness of the coated and the back side of 100Cr6 steel plates. Electrochemical corrosion tests were performed in O{sub 2}-saturated acetate buffer of pH 5.6 at 25degC. Chromium nitride and titanium nitride coatings prepared by different physical vapour deposition processes, such as arc, thermionic arc evaporation, magnetron sputtering and ion-beam-assisted deposition (IBAD) were compared. The results show that, for sufficient corrosion protection, chromium nitride layers have to be thicker than 500 nm. An increased nitrogen partial pressure in the evaporation chamber of the IBAD process improves the corrosion resistance significantly. The hardness of the substrates was reduced in the case of thermoionic arc evaporation only, indicating a deposition temperature of more than ...
Laser surface alloying with gaseous nitrogen was utilized to improve the wear resistance of a Ti-6Al-4V alloy. Wear-resistant composite coatings reinforced by hard TiN dendrites were produced 'in-situ' on a substrate of a Ti-6Al-4V alloy. The hardness and wear resistance of the laser alloyed coating under two-body abrasive and block-on-ring full-sliding wear conditions were significantly enhanced. (orig.)
A flow field and particle trajectory in a HDD (Hard Disk Drive) between two rotating disks in axisymmetric enclosures is investigated using CFD code FLUENT/UNS. The RNG k-{epsilon} model is used as a turbulent model. In this study, the flow field between two disks are symmetric, and the flow field near the enclosure is very complex. Cross stream vectors are shown both for blowing and no blowing from the hub. The larger a particle, the more fast the particle deposits at the walls. In the case of blowing from the hub, the more fast the particle deposits at the walls. (author). 9 refs., 12 figs., 1 tab.
Wood-plastic combination (WPC) was produced by {gamma}-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).
Wood-plastic combination (WPC) was produced by #gamma#-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
Glow discharge plasma nitriding of AISI 304 austenitic stainless steel has been carried out for different processing time under optimum discharge conditions established by spectroscopic analysis. The treated samples were analysed by X-ray diffraction (XRD) to explore the changes induced in the crystallographic structure. The XRD pattern confirmed the formation of an expanded austenite phase (#gamma#_N) owing to incorporation of nitrogen as an interstitial solid solution in the iron lattice. A Vickers microhardness tester was used to evaluate the surface hardness as a function of indentation depth (#mu#m). The results showed clear evidence of surface changes with substantial increase in surface hardness.
The effects of variable hardness, pH, alkalinity, humics, and suspended clay on the chemical speciation of copper and its toxicity to fathead minnow larvae in Lake Superior water were investigated. Two proposed methods (toxicity factors and chemical speciation) for predicting LC50 values in specific natural waters from laboratory toxicity data and the average site specific values of general water quality parameters were evaluated. The accuracy of the cupric ion-selective electrode in determining CU/sup +2/ activities in ambient and chemically altered Lake Superior water was also determined.
The distributions of the effective numbers of 6q-fluctons in the energy, momentum and distance to the center of mass of nucleus are studied. Many characteristics of these distributions are shown to be universal, i.e. independent of the flucton size. The saturation of the flucton density in A > 80 nuclei and other peculiarities are found, which define different behavior of the effective numbers of fluctons and deuterons. This fact provides an explanation of the known underestimate by a factor of 1.5-6 of the cross sections of hard inclusive (p, p'd) process on nuclei calculated in the quasi-elastic approximation.
The world steel industry and market and the current status and prospects for the Japanese steel industry are discussed with particular reference to China, Europe, and the US. Trends in coking coal supply from Australia, Canada, and Mongolia and changes in demand for hard and semi-soft coking coals are considered. Canadian coal plays a significant role in the hard coking coal and PCI coal markets. This is expected to continue. Emerging concerns include the strong Canadian dollar and increases in fuel and materials costs. Canadian suppliers are asked to improve efficiencies, be competitive in the overall coal chain, and diversify their PCI coal reserves. 14 figs.
The efficiency of NbC on WC grain coarsening in a WC-10wt.%Co hardmetal alloy was demonstrated by hardness measurement and WC granulation observation. The heterogeneous and overall grain growth were controlled. A low temperature experimentally produced NbC was used and compared to the inhibition potential of a commercial NbC powder. The results were the same in terms of structural fineness and hardness. The dispersion of the experimental NbC was not a problem, in spite of its size. The experimental NbC has very large particles, formed by agglomerates of small crystallites. During milling these agglomerates could be broken down. (orig.)
The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...
The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the #alpha#-phase at the higher nitriding ...
The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).
The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.
This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...
The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the chemistry and ...
We have obtained optically clear samples of LuAP:Ce from the Institute of Physical Research, Ashtarak, Armenia, measuring up to 5x5x40 mm{sup 3}. The photo electron yield for a number of theses samples was measured with a Philips XP2020Q photomultiplier tube, and 556 photo electrons per MeV was obtained for the best samples. This is comparable to what is obtained from BGO crystals under the same condition, but a factor of 5 less than what is obtained with an LSO sample of similar dimensions. The light in LuAP:Ce increases with cerium concentration between 0.13 and 0.47%.
A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.
A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).
Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.
MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...
The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
Selenium 79 is a beta emitter produced from (235)U fission and is one of the long half-life radionuclides of interest in nuclear waste disposal problematic because of its potential migration capacity to the surface environment. Measurement of (79)Se is particularly difficult due to its low activity in waste matrices (about 10(-3)Bqg(-1)). A radiochemical procedure based on ion exchange separations was already described in a previous paper. This work presents different applications of the radiochemical separation to waste samples and an improvement of this procedure, including a selective extraction of selenium as diethylselenium in an organic solvent followed by a re-extraction in aqueous medium. This additional step allows the decontamination factor to be increased with the aim of counting (79)Se by liquid scintillation counting. PMID:19071740
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
The electronic structures of the set of molecular clusters of dielectric oxide crystals AWO4 (A = Pb, Cd, Zn), the sizes of which increase sequentially are ab-initio calculated by the Restricted Hartree-Fock (RHF) method. The results of calculations of molecular orbitals and energy dependences of partial densities of electronic states of different clusters are compared each to other and to experimental data. It is found that calculated electronic structures of the tungstate groups and cations which are surrounded in cluster by certain number of the nearest neighbor atoms of the crystals quite well represent the experimentally obtained value of the forbidden gap of corresponding AWO4 crystal. (authors)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
We have investigated the effect of plasma nitriding and plasma nitrocarburizing on the microstructure and properties of electroplated chromium. Plasma nitriding and plasma nitrocarburizing are applied to 15-100 [mu]m thick electroplated hard chromium coatings to increase both the wear and the corrosion resistance. The properties of the plasma-modified hard chromium layers are characterized by measuring the wear resistance with a Taber wear tester and the corrosion resistance with a salt spray fog test. Cyclic voltammetry is performed in a standard electrochemical cell using a 0.5 M H[sub 2]SO[sub 4] solution acidified to pH 0.3. The compound layer after plasma nitriding consists of CrN and Cr[sub 2]N with a maximum hardness of about 1100 HK[sub 0.01]. After plasma nitrocarburizing, Cr[sub 3]C[sub 2] and Cr[sub 7]C[sub 3] are formed. After plasma nitrocarburizing, the maximum hardness is increased up to ...
In the present thesis I discuss the hard spectator interaction amplitude in B {yields} {pi}{pi} at NLO i.e. at O({alpha}{sup 2}{sub s}). This special part of the amplitude, whose LO starts at O({alpha}{sub s}), is defined in the framework of QCD factorization. QCD factorization allows to separate the short- and the long-distance physics in leading power in an expansion in {lambda}{sub QCD}/m{sub b}, where the short-distance physics can be calculated in a perturbative expansion in {alpha}{sub s}. Compared to other parts of the amplitude hard spectator interactions are formally enhanced by the hard collinear scale {radical}({lambda}{sub QCD}m{sub b}), which occurs next to the mb-scale and leads to an enhancement of {alpha}{sub s}. From a technical point of view the main challenges of this calculation are due to the fact that we have to deal with Feynman integrals that come with up to five external legs and with three ...
Diamond-like carbon thin films for tribological applications were deposited by d.c.-magnetron sputtering of a graphite target in a pure argon atmosphere or in a reactive hydrogen or methane atmosphere at pressures between 0.1 and 1 Pa in a graded constitution to improve adhesion and reduce residual stress. The temperature of the metallic, carbon- and ceramic-like substrates was below 100 C. The mechanical, thermal, electronic and optical properties of the carbon thin films show a significant dependence on the ion energy. Below 220 eV, strongly adherent black conductive films with hardness values up to 2000 HV0.05 were obtained. Hard and superhard diamond-like carbon thin films were deposited in an energy range between 220 and 370 eV with hardness values up to 4000 HV0.05. They are insulating, optically transparent and show a high degree of hardness combined with high compressive stress in the order of 4 ...
Over the past 40 years, cavern storage of LPG's, petrochemicals, such as ethylene and propylene, and other petroleum products has increased dramatically. In 1991, the Gas Processors Association (GPA) lists the total U.S. underground storage capacity for LPG's and related products of approximately 519 million barrels (82.5 million cubic meters) in 1,122 separate caverns. Of this total, 70 are hard rock caverns and the remaining 1,052 are caverns in salt deposits. However, along the eastern seaboard of the U.S. and the Pacific northwest, salt deposits are not available and therefore, storage in hard rocks is required. Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and ...
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).
The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.
drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...
...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...
The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to ...
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the ...
... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...
When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...
... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...
Sintered glass-ceramics were produced from coal fly ashes, red mud from aluminum production and silica fume. The capabilities of Tuncbilek fly ash and a mixture of Orhaneli fly ash, red mud and silica fume to be vitrified and devitrified by sintering process were investigated by means of scanning electron microscopy and X-ray diffraction analysis. To determine the effect of binder in the sintering technique, glass powders were pressed without or with the addition of polyvinyl alcohol. Owing to microstructural observations, density and hardness measurements, it can be said that physical properties and the hardness of the produced samples strongly depended on the crystallization degree of the samples. Toxicity characteristic leaching procedure test results showed that glass-ceramic samples produced by using sintering technique could be considered as nonhazardous materials. Chemical durability of the sintered glass-ceramic samples was also good. ...
Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding the directivity of ...
A systematic study was made on MoSi{sub 2}-based nanolayer coatings. Alternating layers with thickness 1-20 nm were prepared by sputtering. Nitrided MoSi{sub 2} has a very high crystallization temperature, >1000 C, and MoSi{sub 2}Nx (x=3-4) can be used as a stable second phase reinforcement or diffusion barrier coatings. Mechanical properties depend strongly on phase and morphology of the layers: hardness and modulus is significantly increased in the crystallization. The nanolayers have much higher hardness but lower modulus (which project higher toughness in the nanolayers). Wear resistance is improved with decreasing layer thickness. Single phase MoSi{sub 2}Nx (x=0-4.2) has a wide range of hardness and modulus with varying N content and annealing, suggesting the possibility of engineering MoSi{sub 2}Nx to produce different material properties for different mechanical applications. Most of this paper is made up of ...
Direct current (DC) glow discharge plasma nitriding was carried out on three selected surface-roughened AISI 304 stainless steel samples at 833 K under 4 mbar pressures for 24 h in the presence of N{sub 2}:H{sub 2} gas mixtures of 50 : 50 ratios. After plasma nitriding, the phase formation, case depth, surface roughness, and microhardness of a plasma-nitrided layer were evaluated by glancing angle x-ray diffractogram, optical microscope, stylus profilometer, and Vickers microhardness tester techniques. The case depth, surface hardness, and phase formation variations were observed with a variation in initial surface roughness. The diffraction patterns of the plasma-nitrided samples showed the modified intensities of the {alpha} and {gamma} phases along with those of the CrN, Fe{sub 4}N, and Fe{sub 3}N phases. Hardness and case depth variations were observed with a variation in surface roughness. A maximum hardness of 1058 Hv ...
An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.
This paper presents the first results on formation and study of structure and properties of micro- and nanocomposite combined coatings. By means of modeling the deposition processes (deposition conditions, current density-discharge, plasma composition and density, voltage) we formed the three-layer nanocomposite coatings of Ti-Al-N/Ti-N/Al_2O_3. The coating composition, structure and properties were studied using physical and nuclear-physical methods. The Rutherford proton and helium ion backscattering, scanning electron microscopy with microanalysis, grazing incidence X-ray diffraction, as well as nanohardness tests (hardness) were used. Measurements of wear resistance and corrosion resistance in NaCl, HCl and H_2SO_4 solutions were also performed. For testing mechanical properties such characteristics of layered structures as hardness H, elastic modulus E: H"3/E"2 etc. were measured. It is demonstrated that the formed three-layer ...
The plastic displacements around Knoop indentations made in hard titanium/aluminum multilayered films on soft aluminum alloy substrates have been studied. Indentations were cross-sectioned and imaged using the focused-ion-beam (FIB) milling and high-resolution scanning electron microscopy (SEM), respectively. The FIB milling method has the advantage of removing material in a localized region without producing mechanical damage to the specimen. The micrographs of the cross-sectioned indentations indicate that most of the plastic deformation around the indentation is dominated by the soft aluminum substrate. There is a very small change in the multilayered film thickness around the indentation{emdash}less than 10{percent}. The plastic deformation of the thin film resembles a membrane being deflected by a localized pressure gradient across the membrane. Stress-induced voids are also observed in the multilayered film, especially in the area around the indentation apex. ...
Al{sub x}Ga{sub 1{minus}x}P layers (0 {le} x {le} 0.7), with thicknesses of {ge}1 {micro}m were grown on Si (100) wafers by metal-organic molecular beam epitaxy (MOMBE) at 450 C. Transmission electron micrographs of the single crystal films revealed that the microstructure contains stacking faults and microtwins especially near the interface as well as both threading and misfit dislocations. Hardness and elastic modulus were measured using a Nanotest 500 indenter, which can probe the film properties without influence from the substrate. The hardness H varies linearly according to (11.8 {minus} 2.3x) GPa. The absence of alloy hardening is due to the fact that there is no difference in atomic size of Al and Ga. The indentation modulus E/(1{minus}v{sup 2}) decreases monotonically from 136 GPa for GaP to 129 GPa for Al{sub 0.7}Ga{sub 0.3}P and bows only slightly (about 2%) below the straight line of linear interpolation.
The effects of key metallurgical variables on the low fluence hardening in a set of A533B model steels were evaluated over a wide range of irradiation temperatures. Above about 163 degrees C hardening increased with higher copper and nickel contents, as is typical of the pressure vessel operating regime around 290 degrees C. However, at 121 degrees C the hardening was generally lower and unaffected by copper and nickel variations. This observation of decreased hardening with lower temperature (e.g. an open-quotes invertedclose quotes temperature dependence) is tentatively attributed to a reduced contribution of copper precipitation. Tensile data for a set of commercial steels with a range of (uncontrolled) compositions also showed minimal sensitivity to copper variations at 121 degrees C. Unlike the hardness data no systematic reductions in the yield stress increases were observed between 163 and 121 degrees C. However, the ultimate tensile strength did decrease at ...
A wear-resistant nitrided layer was formed on a 304L austenitic stainless steel substrate by DC plasma nitriding. Effects of DC plasma nitriding parameters on the structural phases, micro-hardness and dry-sliding wear behavior of the nitrided layer were investigated by optical microscopy, X-ray diffraction, scanning electron microscopy, micro-hardness testing and ring-on-block wear testing. The results show that the highest surface hardness over a case depth of about 10 #mu#m is obtained after nitriding at 460 deg. C. XRD indicated a single expanded austenite phase and a single CrN nitride phase were formed at 350 deg. C and 480 deg. C, respectively. In addition, the S-phase layers formed on the samples provided the best dry-sliding wear resistance under the ring-on-block contact configuration test.
In this work, an attempt was made to develop a novel type of wear-resistant composite employing a TiNi alloy matrix reinforced by hard particles. Titanium carbide was chosen as the reinforcing phase because of its high hardness and TiNi alloy as the matrix due to its pseudoelasticity and good toughness. TiC particles may sustain external load, while the TiNi matrix may accommodate deformation, absorb impact energy and retain the hard particles. Such a combination is expected to lead to an enhanced wear resistance, compared to TiNi alloy. As a matter of fact, some efforts were previously made to develop TiNi-matrix composite reinforced by ceramic particles. However, the emphasis of those studies was put on effects of the reinforcing particles on the phase transformation behavior, shape memory effect and some mechanical properties of the composite; no attempt was made to explore the potential benefit of the material for wear ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross section is a well known standard one. The result of the {sup ...
The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10{sup -5} bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of {epsilon} and {gamma}' nitrides in the compound layer, with a preferential formation of {gamma}' at the expense of the {alpha}-phase at the ...
Thin films of new metastable materials from the system Ti-B-C-N were deposited on metallic substrates by d.c. magnetron sputtering in different Ar+N{sub 2} atmospheres. The multiphase compound targets used were based on various compositions on the TiC-TiB{sub 2} and TiB{sub 2}-C tie lines of the Ti-B-C phase diagram. The structure and chemical composition of the films were characterized by electron microprobe analysis, depth profiling Auger electron spectroscopy, X-ray diffraction and transmission electron microscopy. The hardness, critical load of failure and the tribological behavior of the coatings were investigated. Superhard single-phase crystalline metastable Ti-B-C-N layers with hardness values exceeding 5000 HV{sub 0.05} and extremely low sliding wear against 100Cr6 and Al{sub 2}O{sub 3} counterparts could be produced by reactive sputtering of various TiC-TiB{sub 2} targets in Ar+N{sub 2} atmospheres with low nitrogen flows. In the case ...
The influences of temperature and duration of tempering on hardness and microstructure were investigated at high-temperature martensitic and low-carbon steels with 9% chrome and the further alloying elements molybdenium, vanadium, niobium and partially tungsten. After austenitizing and subsequent air cooling the steels were tempered at temperatures below, at and above Ac{sub 1b} for different times and finally a hardness test was performed. Making use of the temperature dependence of the hardness tempering diagrams were constructed and the Hollomon-Jaffe-Parameter on the three steels was determined within its application limits. Micrographs of the structure shows the formation of the carbides and the martensite. At tempering temperatures below Ac{sub 1b} a decrease of hardness occurs, above Ac{sub 1b}, a hardness rise due to the partial austenitizing was obtained. While hardening ...
In a forthcoming paper we describe a new approach to rapidity gap survival (RGS) in the production of high-mass systems (H = dijet, Higgs, etc.) in exclusive double-gap diffractive pp scattering, pp -> p + H + p. It is based on the idea that hard and soft interactions are approximately independent (QCD factorization), and allows us to calculate the RGS probability in a model-independent way in terms of the gluon generalized parton distributions (GPDs) in the colliding protons and the pp elastic scattering amplitude. Here we focus on the transverse momentum dependence of the cross section. By measuring the ''diffraction pattern'', one can perform detailed tests of the interplay of hard and soft interactions, and even extract information about the gluon GPD in the proton from the data.
The NACE MR-01-75 standard imposes a restriction of 22HRC maximum for regions of a pipeline girth weld that are not in direct contact with H[sub 2]S containing environments. TWI have demonstrated in an earlier project for the Pipeline Research Committee (PRC) that it may be permissible to relax this maximum hardness requirement. Such a relaxation, which already exists in the BS4515: 1984 standard, offers potential benefits when applied to the capping pass and heat affected zone of a pipeline girth weld. This report presents additional data to supplement that obtained in a previous PRC project conducted at TWI. Further pipe materials with differing pipe wall thicknesses have been welded, exposed to an internal H[sub 2]S containing environment and examined for sulphide stress corrosion cracking.
A series of nine model ferritic alloys were ion irradiated at #propor to#300 C using 2.5 MeV He ions to a dose of 1.4 x 10"2"1 ion/m"2, which corresponds to #propor to#0.1 dpa at a depth of 2 #mu#m and #propor to#3.5 dpa at the peak damage region which occurs at about 4 #mu#m deep. The resultant changes in hardness as a function of depth were measured using a Nanoindenter "t"r"a"d"e"m"a"r"k. TEM was used to investigate the defect distributions. The effect of various solutes, Cu and N in particular, but Mn and Ti as well, on the change of hardness and the defect distribution due to the ion irradiation are discussed. (orig.).
The corrosion behavior of hard metals with VC and Cr3C2 grain growth inhibitors was investigated in alkaline solutions by electrochemical methods. The two inhibitors have opposite effects on the corrosion behavior: Cr3C2 significantly improves the corrosion behavior, whereas VC-containing alloys show a poor resistance. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and analytical transmission electron microscopy (TEM) analyses of the distributions of Cr and V in the composite material, as well as in the surface layers formed during corrosion were employed to clarify the influence of these elements on the corrosion behavior. The measurements showed that VC is precipitated mostly along the WC/binder interface after the liquid-phase sintering process, while Cr3C2 is almost homogene...
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
To clarify the mechanism of plasma nitriding, the authors examined the optical microstructure, the hardness, the precipitation, and the concentration of dissolved nitrogen in Fe-18Cr-9Ni nitrided using plasma in the range of 723-823 K. Compared with ammonia-gas nitriding, the features of plasma nitriding are the formation of small chromium-nitride precipitates (CrN), the absence of an externally nitrided layer, the high concentration of dissolved nitrogen, and the high hardness (HV = 1,200). The diffusion coefficient of nitrogen in the present alloy was determined using the growth rate of the internally nitrided layer, based on calculations used in internal oxidation. Plasma- and gas-nitriding were also compared with respect to the growth rate of the nitrided layer.
In the present investigation, the properties of plasma nitrided AISI 304 steel were studied by changing the presence of nitrogen in the gas mixture. The plasma nitriding was performed at temperature -560 deg C, pressure -4 mbar and duration 24 hours. The nitrided samples were characterized by evaluating the phase composition, micro hardness, and diffusion layer thickness. The phase analysis indicates the mixed phases of CrN and Fe_3N, Fe_3N and Fe_4N which has the highest intensity. The results show the glow discharge plasma nitriding in presence of N_2 (80 vol. %) and H_2 (rest) produced higher hardness as well as higher case depth. (author)
A polymer-based additive that permanently reduces hardness in wood electrical transmission poles treated with a chromated copper arsenate (CCA) preservative, has been developed by a team of IREQ researchers. A three-phase project is being funded by Hydro-Quebec to evaluate the additive's effect on full-size hydro poles subjected to actual climatic conditions. The evaluation project is designed to test the CCA and the additive's degree of retention by analyzing the hardness measurements against climbing tests, and the washing resistance of the chromium, copper and arsenate in the CCA/polymer-additive treatment. CCA-treated poles will be used for reference. Accelerated aging tests to characterize the polymer's resistance to UV rays will also be part of the validation program.
With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown that an increase of the mean energy of the ...
Modifications of the structure and mechanical properties in LiF crystals irradiated with MeV-energy Au ions have been studied using nanoindentation, atomic force microscopy and optical spectroscopy. The nanostructuring of crystals under a high-fluence irradiation (above 1013 ions/cm2)?was?observed. Nanoindentation tests show a strong ion-induced increase of hardness (up?to 150?200%), which is related to the high volume concentration of complex color centers, defect aggregates, dislocation loops and grain boundaries acting as strong barriers for dislocations. From the?depth profiling of the hardness and energy loss it follows that both nuclear and electronic stopping mechanisms of MeV Au ions contribute to the creation of damage and hardening. Whereas the electronic stopping is dominating i...
Given the important role of parent-youth communication in adolescent well-being and quality of life, we sought to examine the relationship between specific communication variables and youth perceived quality of life in general and as a deaf or hard-of-hearing (DHH) individual. A convenience sample of 230 youth (mean age = 14.1, standard deviation = 2.2; 24% used sign only, 40% speech only, and 36% sign + speech) was surveyed on communication-related issues, generic and DHH-specific quality of life, and depression symptoms. Higher youth perception of their ability to understand parents' communication was significantly correlated with perceived quality of life as well as lower reported depressive symptoms and lower perceived stigma. Youth who use speech as their single mode of communication ...
A Y-Mg-Si-Al-O-N glass was submitted to swift heavy-ion bombardment at GANIL (Caen, France) and the influence of irradiation on the mechanical properties was studied. The mechanical properties of the glass were characterized both before and after irradiation. Changes in hardness, elastic modulus and fracture toughness of the near-surface irradiated layer were determined using indentation techniques. SRIM calculations allowed to estimate the ions penetration range and the energy deposition relative to electronic and nuclear interactions, which can be correlated to the experimental damaged depth. Meyer's hardness and Young's modulus decrease by about 30 %, while fracture toughness is increased by more than 40 %. (authors)
Magnetic properties of Fe-Co-Mo-Cu-B alloy system with Co up to 26at.% were investigated. After proper thermal treatment, the nanocrystalline grain remains tiny, the density hardly increases, but the room-temperature saturation attains 1.5T mainly due to a high enough Curie temperature. The generally observed slant hysteresis loops point to ribbon surfaces, which stress the ribbon interior and induce a specific magnetoelastic contribution to hard-ribbon-axis magnetic anisotropy even after vacuum annealing. The effect does not come from cobalt but rather from the lack of silicon. Partial removal of the surfaces resulted in a decrease of the loop tilt.
The effect of various hydrogen concentrations on the crystal lattice period and the hardness of titanium alloy was examined, the alloy containing about 16 at.% Mo (27.5 wt. % Mo) and having #beta# structure. The peculiar features of the mechanism of plastic deformation of the alloy were studied after adding hydrogen to it. A dependence of the crystal lattice period on the concentration of hydrogen was obtained for TixMoxH_2 alloy. It has been established that the hardness of the Ti-Mo alloy does not change when hydrogen is added to it. The presence of hydrogen introduces changes into the mechanism of deformation of #beta#-titanium alloy. The configuration of the inverse pole figures after rolling proves that the transverse slip process in an alloy with hydrogen is hampered, and that the coplanar slip process is developing in it.
A test bench was designed and assembled to carry out impact tests on samples and components. The system allows simple and rapid adjustment of the test parameters, such as the shot size and air pressure, with good repeatability of the results. Tests on steel and light alloys were carried out under both as-produced condition and on thin hard-coated samples. Significant reductions in dimple dimensions were seen after coating. FE models simulating the experiments overestimated the dimple depths, although the parameter trend was satisfactorily captured. The residual stresses from coating and shot peening determined numerically are believed to have been proven effective against fatigue.
Ochratoxin A (OTA) was analyzed from 44 liquorice confectionery samples using immunoaffinity cleanup and liquid chromatography coupled with fluorescence detection. The presence of OTA was confirmed by methyl-ester derivatization. Liquorice confectionery samples were purchased from different retail outlets and supermarkets in Spain during 2007-2008, 16 of hard candies and 28 of soft candies. The incidence of OTA varied between 75% and 39% and mean ranged from 2.96 to 0.34mg/kg for hard and soft candies, respectively. Assuming a total mean value of 1.29mgOTA/kg sweet and a consumption of about 1.2g liquorice sweets per day, an OTA weekly uptake of 11ng was obtained, or, based on a total body weight of 30kg for a child consuming these sweets regularly, a weekly intake of 0.37ng/kg body weight...
Effect of oil palm empty fruit bunch (OPEFB) fiber and poly(methyl acrylate) grafted OPEFB on several mechanical properties of poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blends using HAKEE Rheomixer at the rotor speed of 50 rpm, mixing temperature 150degreeC, and mixing period of 20 min. The fiber loadings were varied from 0 to 30% and the effect of fiber content in the composites on their ultimate tensile strength (UTS), Youngs modulus, elongation at break, flexural modulus, hardness, and impact strength were determined. An increasing trend was observed in the Youngs modulus, flexural modulus, and hardness with the addition of grafted and ungrafted fiber to the PVC/ENR blends. However the i...
AISI 5140 steel was plasma nitrided at various gas mixtures of nitrogen, hydrogen, and argon to investigate the actions of hydrogen and argon on plasma nitriding. The structural and mechanical properties of ion-nitrided AISI 5140 steel have been assessed by evaluating composition of phases, surface hardness, compound layer thickness, and case depth by using X-ray diffraction (XRD), microhardness tests, and scanning electron microscopy (SEM). It was found that the growth of compound layer can be controlled and the diffusion improved when the gas mixture includes H_2 gas. Additionally, it was determined that the amount of Ar in dual gas mixture must be at 20% minimum to obtain distinctive surface hardness and compound layer thickness.
In this work AISI 1045 steel were duplex treated via plasma nitriding of chromized layer. Samples were pack chromized by using a powder mixture consisting of ferrochromium, ammonium chloride and alumina at 1273K for 5h. The samples were then plasma-nitrided for 5h at 803K and 823K, in a gas mixture of 75%N2+25%H2. The treated specimens were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) analysis and Vickers micro-hardness test. The thickness of chromized layer before nitriding was about 8mm and it was increased after plasma nitriding. According to XRD analysis, the chromized layer was composed of chromium and iron carbides. Plasma nitriding of chromized layer resulted in the formation of chromium and iron nitrides and carbides. The hardness of the duplex layer...
The energy, angular momentum, and distance (measured from the center of mass of the nucleus) distributions of the effective number of 6q-fluctons are investigated and it is shown that many of the characteristics of these distributions are universal, i.e., independent of the flucton size. ''Saturation'' of the flucton density in nuclei with mass A approx > 80 and certain other features that determine the difference between the behaviors of the effective numbers of fluctons and deuterons are reported. This is used to explain the well known underestimation (by a factor of 1.5--6) of the cross section for the hard inclusive (p, p'd) process on nuclei calculated in the quasielastic formalism. See S. G. Kadmenskii and V. I. Furman, Alpha decay and elated nuclear reactions (in Russian), Energoatomizdat, Moscow, 1985.
The energy, angular momentum, and distance (measured from the center of mass of the nucleus) distributions of the effective number of 6/ital q/-fluctons are investigated and it is shown that many of the characteristics of these distributions are universal, i.e., independent of the flucton size. ''Saturation'' of the flucton density in nuclei with mass /ital A//approx gt/80 and certain other features that determine the difference between the behaviors of the effective numbers of fluctons and deuterons are reported. This is used to explain the well known underestimation (by a factor of 1.5--6) of the cross section for the hard inclusive (/ital p/, /ital p/'/ital d/) process on nuclei calculated in the quasielastic formalism. See S. G. Kadmenskii and V. I. Furman, /ital Alpha/ /ital decay/ /ital and elated/ /ital nuclear/ /reactions/ (in Russian), Energoatomizdat, Moscow, 1985.
Microstructural observations of damage around indentations in Ti{sub 3}SiC{sub 2} are presented. The Vickers hardness decreased with increasing load and asymptotically approached 4 GPa at the highest loads. No indentation cracks were observed even at loads as high as 300 N. Preliminary strength versus indentation plots indicate that, at least for the large-grained material ({approx}100 {micro}m) studied here, Ti{sub 3}SiC{sub 2} is a damage-tolerant material able to contain the extent of microdamage to a small area around the indent. The following multiple energy-absorbing mechanisms have been identified from scanning electron micrographs of areas in the vicinity of the indentation: diffuse microcracking, delamination, crack deflection, grain push-out, grain pull-out, and the buckling of individual grains.
The combined processes of plasma nitriding and cathodic arc deposition of (Ti,Cr,Nb)CN coatings were applied to HSS substrates. The nitrided layers, obtained in a mixture of H2 (70%) and N2 (30%) at two different temperatures (480^oC and 510^oC), were examined for the microhardness depth profiles. Characterization of the duplex coatings was performed by investigating elemental and phase composition, texture, hardness, friction and wear. XRD and XPS analyses revealed the formation of a mixture of a carbonitride fcc solid solution, in a dominant proportion, and metallic chromium. The film hardness was measured to be ~34GPa. The duplex (Ti,Cr,Nb)CN coatings exhibited superior tribological behavior as compared to both nitrided layers and non-duplex coatings.
The following topics are discussed: insertion of incorrect bases in DNA; ability of DNA polymerase to copy uv-irradiated DNA; role of enzymes in repair of DNA; effects of uv radiation on molecular weight of DNA; photoreactivation; repair of DNA in Escherichia coli and xp cells following uv radiation; and synchrotron radiation studies on DNA repair. (HLW)
The book is divided into two approximately equal parts. The first four chapters are relatively lengthy and cover the basic principles of radiation biology, carcinogenesis and therapy, along with a brief introduction to radiological physics to orient the reader without background in this specialized related discipline. The remainder consists of twenty-four relatively brief chapters, each covering the radiation biology of a specific organ, tissue, or systems tissues, with emphasis on the tumorigenic and tumoricidal action of ionizing radiations.
The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.
In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.
External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.
Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).
BackgroundTo compare two strategies of dynamic intensity modulated radiation therapy (dIMRT) with 3-dimensional conformal radiation therapy (3DCRT) in the setting of hypofractionated...Full Text Available
Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).
We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge ...
The influence of a periodic electromagnetic field on the radiative corrections to the atomic energy levels is studied for the case of ''strong fields'' for which the interaction between the atom and field is of the order or greater than the radiative effects. The analysis is carried out on the basis of the Schwinger-Dirac equation for the propagation function of a bound electron in the field and on the basis of the density matrix in the Furry representation. It is shown that in the strong field approximation the radiative shifts and widths are manifest as radiative corrections to the quasi-energies. In super-high resolution experiments intensity effects in the radiative corrections to the atomic levels are obtained in the case of single-photon resonance. Some multiphoton processes are condidered by taking into account the effect of the field on ...
The stages of processes leading to radiation damage are studied, as well as, the direct and indirect mechanics of its production. The radiation effects on nucleic acid and protein macro moleculas are treated. The physical and chemical factors that modify radiosensibility are analysed, in particular the oxygen effects, the sensibilization by analogues of nitrogen bases, post-effects, chemical protection and inherent cell factors. Consideration is given to restoration processes by excision of injured fragments, the bloching of the excision restoration processes, the restoration of lesions caused by ionizing radiations and to the restoration by genetic recombination. Referring to somatic effects of radiation, the early ones and the acute syndrome of radiation are discussed. The difference of radiosensibility observed in mammalian cells and main observable alterations in tissues and ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...
The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation. (author).
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.
The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
Investigations were carried out of radiation level around Daya Bay for three times since the construction and operation Daya bay Nuclear Power Station and Lingao Nuclear Power Station in Guangdong province in the period of 1988 to 2000. As shown by the investigation, the radiation levels both in the field and indoors remains unchanged by and large but slightly higher than before on the roads. Also this paper gives the analysis of variations in radiation levels form site to site and from time to time. It was shown that, for environmental ? radiation levels measurements, typical measuring sites have significant impact on the meaning results. (authors)
Conventional plasma carburizing or nitriding for austenitic stainless steels results in a degradation of corrosion resistance. However, a low temperature plasma surface treatment can improve surface hardness without deteriorating the corrosion resistance. The 2-step low temperature plasma processes (the combined carburizing and post nitriding) offers the increase of both surface hardness and thickness of hardened layer and corrosion resistance than the individually processed low temperature nitriding and low temperature carburizing techniques. In the present paper, attempts have been made to investigate the influence of the introduction of Ar gas (0#approx#20%) in nitriding atmosphere during low temperature plasma nitriding at 370 .deg. C after low temperature plasma carburizing at 470 .deg. C. All treated specimens exhibited the increase of the surface hardness with increasing Ar level in the atmosphere and the surface ...
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
Olive oil mill wastewaters (OMW) cause disposal problems because they contain powerful pollutants such as phenolic compounds. Complete biodegradation or removal of these compounds is hardly achieved by a single treatment method. In this work, we investigated 2 integrated technologies for the treatment of the recalcitrant contaminants of OMW, allowing water recovery and reuse for agricultural purposes. (Author)
All over the world the implementation of energy efficient and clean technologies can be hardly considered without opening the way to competition and the involvement of private investment. If such terms are valid for reach countries there are even more adequate for economies in transition like Romania's, which inherited and obsolete productive equipment, can mobilize insufficient resources for development-modernization and exhibits a quasi-unanimous option of adhering at European Union. (author). 3 tabs., 11 refs.
In the year 2008, the high pressure partial turbine and two low pressure partial turbines in the hard coal power station Bergkamen (Federal Republic of Germany) were modernized. A three-dimensional blade design and innovative seals were used. This resulted into a distinct increase in efficiency among other things.
This study by CTES, L.C. meets two main objectives. First, evaluate the feasibility of using coiled tubing (CT) to drill 1.0 inches-2.5 inches diameter directional holes in hard rocks. Second, develop a conceptual design for a micro borehole drilling platform (MBDP) meeting specific size, weight, and performance requirements. The Statement of Work (SOW) in Appendix A contains detailed specifications for the feasibility study and conceptual design.
This statement summarizes Lawrence Livermore National Laboratory`s committment to making important scientific, technological, and business contributions to global sustainability. The quest has many aspects, some socio-political or economic and some technological, and some in which the soft and hard sciences become indistinguishable, as in visionary national strategies, like Holland`s, and futuristic regional and city development plans, like those of Kagoshima and Chattanooga.
The loosening equipment consists of a base machine and four-link suspension mechanism which is a cross frame with loosening gear connected to the base machine by universal hinges. In order to improve the reliability of the machine, the drive of transverse shifting in the cross frame is made of symmetrically arranged, shock-absorbing, hydraulic cylinders which are connected by additional universal hinges to the base machine and the lower pull rods. The design of the loosening machine guarantees its reliable operation on soil with significant quantity of hard inclusions.
With the frequent load changes to which a hard coal power station is subjected in the middle and peak load range, great demands are linked with the transient behaviour of the steam generator. Due to the serial connection of the crusher and boiler, the strongly delaying transient behaviour of the crusher compounds entirely with the transient behaviour of the steam generator. Therefore, a suggestion is to be made here as to the improvement of the dynamics of the crusher.
The competitiveness of a new nuclear plant vs. a new oil or gas fired combined cycle plant or a coal fired plant in East-Asia, is reviewed in the paper. Both the nuclear and the fossil fired plants are evaluated as either utility financed or independent power producer (IPP) financed. Two types of advanced light water reactors (ALWRs) are considered in this paper, namely evolutionary ALWRs (1200 MWe size) and passive ALWRs (600 MWe class). A range of capital and total generation costs for each plant type is reported here. The comparison centers on three elements of overall competitiveness: generation costs, hard currency requirements, and employment requirements. Each of these aspects is considered perspective. Year-by-Year generation cost history over the plant lifetime is shown in some cases. It is found here that a utility financed evolutionary and passive ALWRs are broadly competitive with an IPP financed gas fired combined cycle plant and are more economic than ...
Geological, geophysical, and engineering-geological research conducted at the 'Yeniseisky' site obtained data on climatic, geomorphologic, geological conditions, structure and properties of composing rock, and conditions of underground water recharge and discharge. These results provide sufficient information to make an estimate of the suitability of locating a radioactive waste (R W) underground isolation facility at the Nizhnekansky granitoid massif
The removal of tritiated water vapour was tested by use of a small burning apparatus and a clinoptilolite filter. It was found that decontamination factor of about 10"4 could be obtained by a clinoptilolite filter. The adsorption of HTO in the clinoptilolite is caused by the diffusion, so it is necessary that filtration velocity is maintained below 0.01 m/sec. Decontamination factor was not influence by the moisture content of a clinoptilolite and tritiated water vapour once adsorbed on a filter was hardly removed. (auth.).
A systematic study of structure-mechanical properties relation is reported for MoSi{sub 2}-SiC nanolayer composites. Alternating layers of MoSi{sub 2} and SiC were synthesized by DC magnetron and rf-diode sputtering, respectively. Cross-sectional transmission electron microscopy was used to examine three distinct reactions in the specimens when exposed to different annealing conditions: Crystallization and phase transformation of MoSi{sub 2}, crystallization of SiC, and spheroidization of the layer structures. Nanoindentation was employed to characterize the mechanical response as a function of structural changes. As-sputtered material exhibits amorphous structures in both types of layers and has a hardness of 11 GPa and a modulus of 217GPa. Subsequent heat treatment induces crystallization of MoSi{sub 2} to form the C40 structure at 500C and SiC to form the a structure at 700C. The crystallization process is directly responsible for hardness ...
The mechanisms underlying life machinery are still not completely understood. Something is known, something is ?probably? known, other things are still unknown. Scientists all over the world are working very hard to clarify the processes regulating the cell life cycle and bioinformaticians try to support them by developing specialized automated tools. Within the plethora of applications devoted to the study of life mechanisms, tools for the analysis and comparison of biological networks are catching the attention of many researchers. It is interesting to investigate why.
Platelet-rich plasma (PRP) is a platelet concentrate that has widely been used to accelerate the healing of soft and hard tissues. The preparation of PRP has been described by several authors. Preparation protocols vary from system to system, depending on the concentration of different integrating proteins. The objective of this article is to describe the principal use of PRP mixed with fat grafts in aesthetic plastic surgery.