Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiationdosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiationdosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation ...
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. ...
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data ...
The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.
The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are ...
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the ...
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been ...
The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available
A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement ...
This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.
BackgroundThe use of fractionated stereotactic radiotherapy (fsrt) has evolved with technical advances in noninvasive immobilization, radiation delivery, and image guidance....Full Text Available
The challenges of lung cancer radiotherapy are intra/inter-fraction tumor/organ anatomy/motion changes and the need to spare surrounding critical structures. Evolving radiotherapy technologies, such...Full Text Available
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...
Nov 8, 2010 ... Ihring Mission 11, the radiationdosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.
In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available
In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of ...
The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of ...
SummaryRadiotherapy is used commonly in the treatment of gynecologic malignancies. Many patients experience emotional distress prior to the initiation of radiotherapy, during...Full Text Available
Intensity modulated radiotherapy (IMRT) is widely used in clinical applications in developed countries, for the treatment of malignant and non-malignant diseases. This technique uses multiple radiation...Full Text Available
IntroductionRadiotherapy outcomes might be further improved by a greater understanding of the individual variations in normal tissue reactions that determine tolerance. Most published...Full Text Available
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
The purpose of this article is to review the literature for clinical presentation, treatment, outcome and complications of using radiotherapy for the treatment of orbital lymphoma. For this, MEDLINE,...Full Text Available
Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available
Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
The initial management of nonfunctioning pituitary macroadenomas (NFAs) is usually surgery; however, a significant proportion of NFAs may require further treatment. Radiotherapy is currently used in patients with residual tumour and achieves excellent long-term control, but there are concerns about potential late toxicity. Stereotactic radiotherapy, both in the form of radiosurgery or fractionated stereotactic radiotherapy, has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. A review of the literature suggests that new radiation techniques offer safe and effective treatment for recurrent or residual pituitary adenomas; how...
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.
PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available
Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.
This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, ...
This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical ...
Results of treatment of 30 children with Ewing's sarcoma irradiated in the First Radiotherapy Department, Cancer Center, Warsaw, in the period 1983-1992, are described. In 40% of patients NED survival from 1 till 10 years and in 70% the local control was obtained, and no serious radiations equelae were observed. (author).
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, ...
ObjectivesTo assess the influence of epigallocatechin-3-gallate (EGCG) on the efficacy of ionizing radiation on prostate cancer cells because of the increased use of dietary interventions, especially by patients with prostate cancer. Radiotherapy is used to treat localized prostate cancer. Some people consume green tea (EGCG) as a chemopreventive agent against prostate cancer. Green tea can act as an antioxidant and induce superoxide dismutase enzymes, which could scavenge the free oxygen radicals generated by radiotherapy. MethodsProstate cancer cell line DU145 cells were treated with EGCG or radiotherapy, or both. Cell death was assessed using trypan blue cell counting, and apoptosis was confirmed by assessing poly (adenosine phosphate ribose) polymerase cleavage. The antioxidant potenti...
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available
DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.
The document, based on European guidelines, was jointly developed by radiation oncologists, radiation physicists and radiation technologists. It contains the aims of the guidelines, professional profiles, roles and responsibilities, personnel and equipment requirements, procedures.
Passive dosimeters for personal and area radiation monitor in space have been developed mainly for dosimetry in low-earth-orbit (LEO) radiation environments of Space Shuttles and the International Space Station. The responses of several dosimeters have been evaluated by heavy ions and also its variation for individual dosimeter element. (author)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is ...
This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of DosimetryRadiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing ...
Purpose: We present an update analysis of the multiinstitutional Ewing's sarcoma study CESS 86. Methods and Materials: From January 1986 through June 1991, 177 patients with localized Ewing's sarcoma of bone, aged 25 years or less, were recruited. Chemotherapy consisted of four 9-week courses of vincristine, actinomycin D, cyclophosphamide, and adriamycin (VACA) in low-risk tumors (extremity tumors =# 100 cm"3). Local therapy was an individual decision in each patient and was either radical surgery (amputation, wide resection) or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy (45 Gy plus boost). Irradiated patients were randomized concerning the type of fractionation in either conventional fractionation (once daily 1.8-2.0 Gy, break of chemotherapy) or hyperfractionated split-course irradiation simultaneously with the VACA/VAIA chemotherapy (twice daily 1.6 Gy, break of 12 days after 22.4 Gy and 44.8 Gy, total dose and ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true ...
Background: The effective-dose method which was proposed by the ICRP (International Commission of Radiation Protection) for the estimation of risk to the general population from occupational or environmental, low-dose radiation exposure is not adequate for estimating the risk of cancer induction by radiotherapy of malignant or nonmalignant diseases. Methods:The risk of cancer induction by radiotherapy of benign diseases should be based on epidemiologic data directly derived from follow-up studies of patients who had been given radiotherapy for nonmalignant diseases in the past. Results: Risk factors were derived from epidemiologic studies of patients treated with irradiation for nonmalignant diseases to be used for selecting treatment options and optimizing treatment procedures. Conclusion: In most cases, cancer risks estimated by the effective-dose method may overestimate the true ...
The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any ...
Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: radiation-induced ...
The use of absorbable polyglactin 910 mesh (Vicryl) is described in a case of Ewing's sarcoma of the pelvis. An operation was performed to hold the small bowel and colon out of the pelvis for a temporary period during which radical radiotherapy was delivered. The mesh allowed the temporary displacement of bowel and obviated bowel radiation morbidity. (author).
Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event-free survival (EFS), and overall survival rates from multidisciplinary therapy in Ewing's sarcoma. Methods and Materials: Between 1983 and 1988, 184 children with Ewing's sarcoma were enrolled onto Pediatric Oncology Group 8346 (POG 8346). A total of 178 (97%) met eligibility criteria; 6 had pathology other than Ewing's sarcoma. Induction chemotherapy of cyclophosphamide/doxorubicin (adriamycin )(C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy and C/A, dactinomycin, and vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. Forty patients were randomized to receive SF, whole bone ...
Purpose: Treatment results and the pattern of relapse were evaluated in the multimodal treatment of Ewing's sarcomas of the chest wall. Methods and Materials: In a retrospective analysis, 114 patients with non-metastatic Ewing's sarcoma of the chest wall were evaluated. They were treated in the CESS 81, CESS 86, or EICESS 92 studies between January 1981 and December 1993. The treatment consisted of polychemotherapy (VACA, VAIA, or EVAIA) and local therapy, either surgery alone (14 patients), radiotherapy alone (28 patients) or a combination of both (71 patients). The median follow-up was 46.6 months (range 5-170). A relapse analysis for all patients with local or combined relapses was performed. Results: Overall survival was 60% after 5 years, event-free survival was 50%. Thirty-seven patients had a systemic relapse (32.4%), 11 patients had a local relapse alone (9.6%), and 3 patients had a combined local and systemic relapse (2.6%). The risk to relapse locally ...
A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.
Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure ...
A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse ...
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).
A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, ...
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
A Pulsed RadiationDosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic ...
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and ...
Two patients who developed large intracranial vessel occlusion after standard radiation therapy for brain tumor are described. This form of vascular occlusion is usually seen in patients who have previously been treated by radiotherapy for intracranial tumor who then develop a relatively acute change in neurologic status. Histology of the lesion mimics accelerated focal arteriosclerosis. The clinical and radiographic manifestations of one case were highly atypical. The vasculopathy became evident shortly after termination of radiation therapy for a fourth ventricular ependymoma, and the angiographic picture stimulated a diffuse arteritis. The second patient was more typical, with clinical symptoms developing 12 years after radiation therapy for an oligodendroglioma. Occlusion of a proximal vessel that had been included in the radiation port was demonstrated radiographically and ...
Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single cells irradiated at very low radiation ...
Electron beam therapy applied to a lymph node metastasis from a squamous cell carcinoma was followed by the development of histologically and immunologically typical bullous pemphigoid, the lesions being initially strictly confined to the irradiation area. This observation suggests that the bullous pemphigoid antigen may be altered or unmasked by electron beam radiotherapy, leading subsequently to the production of autoantibodies. The disease in this case effectively responded to the administration of tetracycline and niacinamide, a therapeutic regimen described recently.
An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).
Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved indications of ...
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be ...
Oral mucositis associated with head and neck radiotherapy can substantially hinder completion of cancer therapy. Alleviation of this often severe stomatitis can provide enhanced patient comfort and facilitate appropriate care. A double-blind format was used in a pilot project to measure, against a control rinse, the effectiveness of an oral rinse consisting of hydrocortisone, nystatin, tetracycline, and diphenhydramine in controlling radiation-related mucositis. A combination of clinical evaluation and patient responses to a questionnaire was used to judge the results of the topical medications. Patients using the experimental medication developed less mucositis than did patients in the control group.
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.
Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 ...
The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiationdosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of current interest in ...
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
Background and Purpose: In an earlier phase II study, irradiation together with razoxane was shown to improve local control in recurrent rectal cancer. Therefore, the Austrian Society of Radiooncology (OeGRO) initiated a randomized controlled trial in 1992 to compare this combined treatment versus radiation therapy alone. Patients and Methods: Between 1992 and 1999, 36 patients with localized recurrences of rectal cancer were randomized to receive radiotherapy without (group A) or with razoxane (group B). The prognostic variables of the two groups were similar except for a longer median latency period from initial surgery to local recurrence in group A. High-energy photons with daily fractions between 170 and 200 cGy were used. The median total radiation dose was 60 Gy in each group. The patients in group B received a median razoxane dose of 9.6 g (range, 5-12 g). Main outcome measures were local control, overall survival, ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. ...
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
A 38 year old male dentist developed an oligodendroglioma of the left medial temporal lobe and parasellar region 12 years after radiotherapy with 6600 rads for acromegaly. The 30 cases of radiation-induced gliomas reported in the English literature are reviewed and analysed. The criteria for defining radiation-induced tumours of the central nervous system are proposed as follows: the tumour has a long quiescent ''latency period'', a location in the previously irradiated field, a verified histological difference from a primary condition, and does not arise from a primary condition associated with a genetic syndrome such as neurofibromatosis or tuberous sclerosis. The reported case fulfilled these criteria but appears to be the only reported radiation-induced oligodendroglioma.
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may ...
The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months ...
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be ...
Seventy-one patients with intestinal injury secondary to pelvic irradiation had predominantly large bowel lesions. Seventeen cases were treated conservatively and 54 came to surgery, 28 patients having more than one operation. Following this essentially salvage surgery there were more ileal than colonic anastomotic leaks. Thirty-four patients died during the follow-up period (2-12 years), 19 from recurrent malignancy, and nine as a result of continuing radiation effects. Seventy per cent of the patients who had a radiation fistula died as a result of malignancy. Of 42000 cases of pelvic malignancy treated by irradiation over the decade 1972-1982, surgical referrals for complications constituted 1.7%, with an overall radiation-related mortality of 0.2%. It is our opinion that colostomy alone has little part to play in this condition, and a policy based on excisional surgery is suggested.
The treatment of locally advanced rectal cancer including timing and dosage of radiotherapy, degree of sphincter preservation with neoadjuvant radiotherapy, and short and long term effects of radiotherapy...Full Text Available
Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system ...
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies establishing a ...
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for ...
We encountered a case of Ewing's sarcoma. The patient was a 19 year-old girl, who visited a local physician because of pain in the left scapular region, and was referred to us. Roentgenograms of her left scapula revealed an irregular moth-eaten shadow which was suspected to be a malignant bone tumor. The histological diagnosis of Ewing's sarcoma was comfirmed by needle biopsy. The initial stage of treatment consisted of radiation therapy (6000 rads) and chemotherapy (VAC and ADR). At the end of the initial stage, the symptoms were improved, the size of the local lesion was reduced on the roentgenogram and there was no evidence of distant metastases. (author).
Purpose: To evaluate the results of radiotherapy in cholangiocarcinoma patients managed with various combinations of chemotherapy and surgical resection with selective liver transplantation. Methods and Materials: From January 1990 to December 1995, 61 patients with histologically confirmed biliary duct adenocarcinoma were seen in the Radiation Oncology Department of the University of Pittsburgh. Median follow-up was 22 months (1 to 91 months). The extent of surgery was complete resection in 23 patients (including 17 with orthotopic liver transplant), partial resection in 4, and biopsy in 34. All patients had radiotherapy; median dose was 49.5 Gy. Thirty patients received chemotherapy: 5-fluorouracil (5-FU)-leucovorin with interferon alpha (IFN#alpha#) in 27, and taxol in 3. Results: The median survival was 20 months (95% CI 15-25 months). The 5-year actuarial survival was 23.8 #+-# 6.8%. The only significant variable in ...
The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was ...
Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy of the mass at the time of referral. They were enrolled on ...
Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a patient and deposited in a phantom at a large ...
Ionizing radiation is a standard treatment for various human solid tumors. However, several clinical studies showed that a significant proportion of patients undergoing radiotherapy for hepatocellular carcinoma (HCC) develop intrahepatic and extrahepatic metastasis. Understanding of radiation-induced cancer cell invasiveness and behavior is essential and of great important for developing suitable treatment strategies to contain cancer spread. Therefore, in this study we evaluated the effectiveness of using swept source optical coherence tomography (SS-OCT) to monitor the enhancement of HCC cell invasiveness by radiation. SS-OCT images were acquired and recorded to obtain three-dimensional data sets per four hours in 48 hours after irradiating HepG2 cells with 7.5 Gy. The cell migration behavior in three-dimensional tissue models was quantified from images of radiation-induced and ...
Two cases of primary Ewing's sarcoma of the rib are reported, in which radiation therapy was quite effective. Case 1 was an 18-year-old female who had had an operation and radiation therapy for Ewing's sarcoma of the left 7th rib. She was referred to our hospital after a recurrent tumor was found. Radiation therapy (tumor dose 46.2 Gy) and chemotherapy were given. The tumor disappeared and there has been no relapse for 1 year and 3 months after the treatment. Case 2 was a 2-year-old-infant. Radiation therapy (tumor dose 74 Gy) was given for primary Ewing's sarcoma of the left 6th rib. The tumor became small and was successfully removed at operation. There has been no relapse or distant metastasis for 8 months following the operation. We emphasize the importance of multidisciplinary treatment in case 1 and the usefulness of preoperative radiotherapy in case 2. (author).
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...
Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD) (follicle-stimulating hormone (FSH), 10 +/- 15 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 ..beta..-estradiol (E/sub 2/) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developd persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 109 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E/sub ...
Ovarian function was evaluated in 11 women 16 to 43 years of age at treatment who received doxorubicin, cyclophosphamide, and high doses of methotrexate with or without radiotherapy in adjuvant therapy of soft tissue sarcoma. Five women (16-33 yr old) who received chemotherapy alone or combined with radiotherapy only at sites distant from the ovaries (chest wall, thigh, and leg) had minimal menstrual irregularities or temporary cessation of menses during therapy; cyclic menses returned promptly after therapy. Gonadotropin levels (expressed as means +/- SD (follicle-stimulating hormone (FSH), 10 +/- 5 mlU/ml; luteinizing hormone (LH), 10 +/- 4 mlU/ml) and 17 beta-estradiol (E2) levels (means +/- SD, 208 +/- 147 pg/ml) were normal. By contrast, 4 older women (ages 36-43 yr) who received similar treatment developed persistent amenorrhea with postmenopausal levels of gonadotropin (FSH, 108 +/- 29 mlU/ml; LH, 72 +/- 19 mlU/ml) and E2 (19 +/- 8 ...
Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum reaching statistical significance. A statistically significant ...
This study examines some radiation accidents occurred in the past. This information has been systematically assessed to get global lessons. The experience feedback shows that the most of accidents happened in certain conditions. These conditions can be distributed in four categories: 1- perception and vigilance in occupation: accidental exposure happened by lack of vigilance in details and lack of vigilance and perception; 2- procedures: accidental exposure happened following a lack of procedures or control that were not enough complete, not enough documented or not completely implemented; 3- training and understanding: accidental exposures happened because the personnel was not enough qualified and educated, did not get the general training nor the the necessary specialized training; 4- liabilities: accidental exposures happened following lacks and ambiguity in the definition of functions of the personnel and in the hierarchy liabilities. In these precise cases ...
The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, ...
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.
Radiotherapy has been reported to be of benefit in prolonging the survival of patients with cholangiocarcinoma. This study examined whether radiotherapy in addition to endoscopic stenting improved survival. The survival advantage of radiotherapy in those with a type II/III stricture is seen only in the first 10 months after diagnosis. The costs of radiotherapy and significantly increased time spent in hospital, however, raise doubts over its routine use in the management of non-resectable cholangiocarcinoma. (Author).
Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer ...
Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of health effect by ...
Radiation necrosis of normal CNS tissue represents one of the main risk factors of brain irradiation, occurring more frequently and earlier at higher total doses and higher doses per fraction. At present, it is believed that the necrosis results due to increasing capillary permeability caused by cytokine release leading to extracellular edema. This process is sustained by endothelial dysfunction, tissue hypoxia, and subsequent necrosis. Consequently, blocking the vascular endothelial growth factor (VEGF) at an early stage could be an option to reduce the development of radiation necrosis by decreasing the vascular permeability. This might help to reverse the pathological mechanisms, improve the symptoms and prevent further progression. A patient with radiation-induced necrosis was treated with an anti-VEGF antibody (bevacizumab), in whom neurologic signs and symptoms improved in accordance with a decrease in T1-weighted ...
Objective: Pretargeting is the concept that combines optimal delivery of the antibody and rapid capture and elimination of the radioactivity. In this study, we evaluated the potential of antibody pretargeting to enable the tumor-targeting {sup 212}Pb for in vivo generation of {sup 212}Bi for {alpha} particle radiotherapy. Methods: The {sup 212}Pb/{sup 212}Bi chelate of DOTA-biotin, as well as their {gamma}-emitting analogues, {sup 203}Pb and {sup 205}Bi, was prepared and characterized. The radiolabeled compounds were injected in animals for evaluation of tumor targeting and normal tissue uptake and retention. In the pretargeting protocol, injection of 400 {mu}g of NR-LU-10 antibody-streptavidin conjugate was given at t=0 h, then 100 {mu}g of N-acetyl-galatosamine-biotin clearing agent was injected at t=20-24 h; finally, 1 {mu}g of {sup 212}Pb/{sup 212}Bi-DOTA-biotin was injected 6 h later. Results: Both {sup 203}Pb and {sup 205}Bi-DOTA-biotin were stable for at ...
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the ...
Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The dependency appears to become weaker at higher concentrations, possibly due to the contribution ...
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available
PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting toxicity, except for Grade 3 anorexia or Grade 3 fatigue alone. RESULTS: A total of 20 patients were ...
Purpose Radiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of pentoxifylline (PTX) and a-tocopherol on cardiac injury in a rat model of RIHD. Methods and Materials Male Sprague-Dawley rats received fractionated local heart irradiation with a daily dose of 9 Gy for 5 days and were observed for 6 months after irradiation. Rats were treated with a combination of PTX, 100 mg/kg/day, and a-tocopherol (20 IU/kg/day) and received these compounds either from 1 week before until 6 months after irradiation or starting 3 months after irradiation, a time point at which histopathologic changes become apparent in our model of RIHD. Results Radiation-induced increases in left ventricular diastolic pressure (in mm Hg: 35 +- 6 after sham...
Experiments were carried out on mice and the subjects irradiated for cancer therapy to evaluate the protective efficacy of a Chinese medicinal herb-compound (CMHC). The lethality and the degree of leucopenia caused by radiation in mice medicated with CMHC were significantly less in comparison with control mice (p less than 0.01 and p less than 0.001, respectively). CMHC significantly improved the WBC and the thrombocytes in irradiated workers (p less than 0.01 and p less than 0.001, respectively). The WBC count of 40 patients under radiotherapy while treated with CMHC recovered from 3450 +/- 77/c.mm to 5425 +/- 264/c.mm (p less than 0.001); whereas, in the control group, without any medication, the WBC count dropped significantly (p less than 0.001). Our results revealed the applicabilities of CMHC in protection against radiation damage in spaceflight and in other fields.
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography showed complete ...
We report a patient who developed occlusion of the intracranial major arteries induced by radiation therapy for craniopharyngioma. The patient, a 9-year-old boy, presented with deterioration of vision, nausea and vomiting. He underwent a right ventriculo-peritoneal shunt operation, and the tumor was partially removed. Postoperatively, he received focal radiation therapy with total of 60 Gy. Preoperative cerebral angiography, cerebral vessels had no sigh of occlusive lesion or stenosis. One year after irradiation, he started to have repeated cerebral ischemic attacks. But no regrowth of the tumor was detected on CT scans. Two years and 8 months after irradiation, he suddenly had right hemiparesis. Cerebral angiography revealed severe stenosis of the right anterior cerebral artery (precommunicating segment), middle cerebral artery (horizontal portion) and terminal portion of the right carotid artery. Left carotid angiography showed complete ...
Purpose : To detect differentially expressed genes in the patients with uterine cervical cancer during the radiation therapy. Materials and Methods : In patients with biopsy proven uterine cervical cancer, we took a tumor tissue just before radiation therapy and at 40 minutes after external irradiation of 1.8 Gy. Total RNAs isolated from non-irradiated and irradiated tumor tissue samples were analyzed using the differential-display reverse transcription-polymerase chain reaction (DDRT-PCR). Complementary DNA (cDNA) fragments corresponding to differentially expressed messenger RNAs(mRNAs) were eluted, and cloned. The differential expression of the corresponding mRNAs was confirmed by reverse northern blot. Differentially expressed cDNA bands were sequenced. Nucleotide sequence data were analyzed in the Gene Bank and EMBL databases via the BLAST network server to identify homologies to known genes or cDNA fragments. Expression pattern of ...
Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these more aggressive tumors.
This study is for chemoradiotherapy of unresectable and recurrent cholangiocarcinoma (CCC). Between April 2005 and March 2007, 5 patients were evaluated for unresectable and recurrent CCC. All patients were performed percutaneous transhepatic biliary drainage (PTBD) and treated with chemoradiotherapy. The radiation method was an external beam radiotherapy (EBRT) and remote after loading system (RALS). The chemotherapy was 5-fluorouracil (FU) and gemcitabine by intravenous injection. Three patients had unresectable and 2 had recurrent CCC. As for the side effects, 4 patients had a slight neutropenia and 1 had an uncontrollable gastric bleeding. No patient had cholangitis. The mean survival time for unresectable and recurrent CCC was 13.7 months and 17 months, respectively. Our results indicated that chemoradiotherapy had been consistent with efficacy in patients with unresectable and recurrent CCC. (author)
Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is ...
The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure.
Background: Some former retrospective studies have suggested that patients with Ewing's sarcoma might have a very high risk for developing secondary sarcomas if treated with radiotherapy. We have evaluated the risk of second malignancies (SM) in patients treated in the German Cooperative Ewing's Sarcoma Studies CESS 81 and CESS 86. Materials and methods: From January 1981 through June 1991, a total number of 674 patients was registered in the two multicentric Ewing's sarcoma trials CESS 81 (1981 through 1985) and CESS 86 (1986 through June 1991). The systemic treatment consisted in both studies of a four-drug-chemotherapy (VACA= vincristine, actinomycin D, cyclophosphamide and adriamycin; or VAIA= vincristine, actinomycin D, ifosfamide and adriamycin) and a total number of four courses, each lasting nine weeks, was recommended by the protocol. Local therapy was either complete surgery or surgery plus postoperative radiotherapy with 36-46Gy or ...
Purpose: Patients with ataxia-telangiectasia (A-T) show greatly increased radiation sensitivity and cancer predisposition. Family studies imply that the otherwise clinically silent heterozygotes of this autosomal recessive disease run a 3.5 to 3.8 higher risk of developing cancer. In vitro studies suggest moderately increased cellular radiation sensitivity of A-T carriers. They may also show elevated clinical radiosensitivity. We retrospectively examined patients who presented with severe adverse reactions during or after standard radiation treatment for mutations in the gene responsible for A-T, ATM, considering a potential means of future identification of radiosensitive individuals prospectively to adjust dosage schedules. Material and Methods: We selected 20 cancer patients (breast, 11; rectum, 2; ENT, 2; bladder, 1; prostate, 1; anus, 1; astrocytoma, 1; Hodgkins lymphoma, 1) with Grade 3 to 4 (RTOG) acute and/or late ...
Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure ...
Alternatives for developing chronic exposure limits for noncancer effects of trichloroethylene (TCE) were evaluated. These alternatives were organized within a framework for dose-response assessment--exposure:dosimetry...Full Text Available
The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in ...
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like ...
Background and purpose: A diagnosis of malignancy and its treatment is a very stressful time for patients and their families. This study was conducted to determine the impact of more intensive written information on patients' anxiety levels. The secondary aim was to determine the impact of this information on patients' satisfaction levels. Materials and methods: This prospective randomized trial consisted of patients with a pathological diagnosis of cancer having radical radiotherapy (RT). Patients were randomized to receive the more intensive information (including written information and a telephone call from the research nurse) or not to receive the more intensive information at the time of their initial consultation with the radiation oncologist. Study questionnaires measuring anxiety (STAI form) were completed prior to their first consultation (baseline) at the time of simulation (pre-RT) and at the completion of ...
Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT ...
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, ...
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were suggested to minimize ...
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical procedures were suggested to minimize ...
Objective The aim of this study was to analyze the clinical results of our adaptive radiation therapy scheme of a two-step intensity-modulated radiotherapy (IMRT) method for nasopharyngeal cancer (NPC) at Kinki University Hospital. Methods Between 2000 and 2007, 35 patients with Stage I-IVB NPC treated by IMRT were included. For all patients, treatment-planning computed tomography was done twice before and during IMRT to a total dose of 60-70 Gy/28-35 fractions (median 68 Gy). Chemotherapy (cisplatin 80 mg/m2/3 weeks x 1-3 courses) was given concurrently with IMRT for 31 patients. Results The 3- and 5-year overall survival rates for the 31 patients treated with concurrent chemotherapy were 88% and 83%, respectively. The 3- and 5-year loco-regional control rates for the 31 patients were 93%...
The status of neutron activation cross sections for some threshold reactions important for reactor materials dosimetry is reviewed. An attempt is made to understand and explain discrepancies between integral and differential data, using recent available experimental results. The importance of standard and benchmark neutron fields for testing differential data for reactor dosimetry is emphasized and the Interlaboratory Reaction Rate (ILRR) program, as well as a similar program pursued by the IAEA, are briefly described.
Background and purpose: Local treatment for non-metastatic Ewing's sarcoma family tumors (ESFTs) is controversial. Results achieved in a single institution in patients with ESFT of the humerus are presented. Materials and methods: Patients treated between 1983 and 2000 for ESFT of the humerus were included. The impact of local treatment (surgery, radiotherapy or both) on outcome was assessed. Results: 55 patients: 34 males (62%); 21 females (38%); mean age: 17.9 (range: 3-40). Local treatment: surgery in 27 patients (49%), radiotherapy in 17 (31%) and surgery followed by radiotherapy in 11 (20%). After a mean follow-up of 15 years (range: 7-25 years), 27 patients (49%) remained continuously disease free, 27 (49%) relapsed and one died of chemotherapy toxicity. The local recurrence rate was 13% overall: 18% (3/17) after radiotherapy, 7% (2/27) after surgery and 19% (2/11) after surgery followed by ...
The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation for this difference is offered. For electron beam ...
The aim of this work is the evaluation of biodistribution and radiationdosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and arteriography as major imaging techniques in orbital ...
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiationdosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of approximately 1.5% (95% ...
The results of 144 previously untreated cases of primary Ewing's sarcoma of bone are reported with a minimum follow-up of 5 years. This series was treated between 1972 and 1982 at Istituto Ortopedico Rizzoli with a combined therapy. The local control of the disease consisted of amputation (ten cases), resection followed by radiation therapy (35-45 Gy) (48 cases) and radiation therapy alone (40-60 Gy) (86 cases). Adjuvant chemotherapy, rigorously standardized, was performed according two different protocols: the first (85 cases treated in the period 1972-1978) consisted of vincristine (VCR) Adriamycin (doxorubicin) (ADM), and cyclophosphamide (EDX); the second (59 cases treated in the period 1979-1982) of VCR, ADM, EDX and dactinomycin (DACT). At a follow-up of 5 to 16 years (median, 9), 59 patients (41%) are continuously disease-free (CDF), 81 (56%) developed metastatic disease and/or local recurrence, and four (3%) had a second malignancy. ...
From 1979 to 1986, 182 patients with biopsy proven diagnosis of Ewing's sarcoma of bone were observed. One hundred of the 182 patients (72 males, 28 females, median age 15.8 years) with localized disease and no previous treatment were treated with chemotherapy (VCR, ADM, CTX, D-ACT) for 15-18 months. Local treatment was radiotherapy (42 patients), surgery (31 patients), or a combination of both (27 pts). Radiation doses ranged from 45 to 64 Gy given with conventional fractionation. Median follow-up was 51.2 months (24-106). Overall and disease-free survival were, respectively, 58.7 and 42.6%. Resected patients tended to have a better local control (Surgery 93.6%, Surgery + Radiation therapy 92.6%, Radiation therapy 69.1%). Disease-free survival was significantly related to the volume of the primary tumor (bulky: 33.2%, not-bulky: 57.7%), to site (extremities 54.6%, central sites 16.6%, other sites ...
Gastrointestinal lymphomas are almost exclusively of a non Hodgkin's type. The Western form is characterized by a higher incidence of stomach location (50 %), a MALT type (mucosa associated lymphoid tissue) (40 %), a B-cell type (90 %), and a high grade (55 %). Chronic infection with Helicobacter pylori is an important risk factor. Mediterranean lymphomas form a particular clinical and pathological entity with diffuse involvement of the small bowel and are frequently being associated with a chronic malabsorption disorder. Eradication of Helicobacter pylori in early lymphomas, and the use of tetracyclines in early Mediterranean lymphomas, have been shown to induce durable remissions. For more advanced gastric lymphomas, treatment usually consists of anthracycline-based chemotherapy followed by involved field radiotherapy. Surgery is usually reserved for complications such as perforation or bleeding, or in some selected cases for salvage after failure of non-surgical ...
The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator tongue-and-groove. The ...
Combination of radiotherapy and chemotherapy (CRC) is actually one important way of research in oncology. Theoretical advantages are: (1) Spatial cooperation; (2) Additivity, which is only obtained if the toxicity of each modality are different; (3) Supra-additivity, which needs a rigorous in vitro definition; the only way to prove it is to make an isobologram analysis. This model has however, some limitations: qualitative variable could not be used, results could be different, depending on the cell line and isoeffect chosen...In fact, a supra-additivity was only demonstrated for cis platinum and etoposide. Interactions mechanisms were: (1) at the molecular level, creation of new lesions or inhibition of radiation lesions repair; (2) At the cellular level, either cytokinetic cooperation with S-phase dependent drugs, or synchronization for the drugs which blocked the cells in M-phase; (3) At the tissular level, reoxygenation, cycle ...
The serum levels of ferritin in 394 patients, including 339 patients with various malignant tumors and 23 with various non-malignant diseases, and 32 healthy subjects were determined. The normal levels of ferritin were 82.7 +- 42.3 ng/ml for males and 42.0 +- 36.9 ng/ml for females. The positive ratio of serum ferritin level was 28% in patients with malignant tumors and 22% in patients with non-malignant diseases. The usefulness of serum ferritin assay in screening for malignant tumors appeared to be limited. High serum levels of ferritin were found in patients with malignant lymphoma (positive ratio: 42%), pulmonary cancer (38%) and esophageal cancer (37%). According to the histological types, epidermoid cancer appeared to produce a higher serum level of ferritin than adenocarcinoma in patients with pulmonary cancer. It was interesting that malignant lymphoma had a high serum level of ferritin in spite of its low serum level of CEA. Carcinoma of the digestive tracts except for ...
According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the incorporation of (mostly airborne) pollution ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a ...
OBJECTIVE: To evaluate prospectively the efficacy of a single fraction of high-dose radiotherapy in patients with Kaposi's sarcoma. PATIENTS: Between 1994 and 2004, 47 patients with Kaposi's sarcoma...Full Text Available
The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area...Full Text Available
The offline adaptive radiotherapy (ART) has been used to effectively correct and compensate the prostate motion and reduce the required margin. The efficacy depends on the characteristics of...Full Text Available
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...
Forty cases of Ewing's sarcoma of various sites had attended the Department of Radiotherapy at the Wanless Hospital and the Miraj Medical Centre, attached to the Government Medical College, Miraj, Maharashtra, from January, 1970 through December, 1979. There were 28 male patients and 12 female patients in the series with a male to female ratio of 2.3:1. The youngest patient in the series was a female of 6 years of age with the tumour in the scapula and the oldest patient was a 32-year-old male with a lesion in the metacarpal bone. Sixty per cent of the cases were seen in the second decade. The average age of the patients was 13.5 years. The bones of the lower extremities were most commonly involved with the highest number (35 per cent) of the cases occurring in the femur. Involvement of the bones of the right side of the body was almost equal to that of the left side. Swelling over the site of the lesion and pain over the swelling were the most common complaints ...
135 patients with histologically proven Ewing's sarcoma, treated at the Institute Gustave Roussy between 1960-1974 were reviewed in order to establish the effectiveness and the complications associated with radiotherapy. In 133 patients, a dose of at least 60 Gy for long bones, 55 Gy for flat bones and 45 Gy for vertebrae was given. 26 major complications (of which more than one occured in certain patients) were observed: 12 cases of growth retardation, loss of joint function in 7 cases, 3 fractures, 2 osteonecroses, 2 cases of delayed healing, one massive soft tissue fibrosis, 1 abdominocutaneous fistula, 2 cases of symptomatic pulmonary fibrosis with associated infection, 2 cases of radiation enteropathy, 2 of mammary hypoplasia and 1 osteosarcoma developing in an irradiated zone. These complications necessitated 12 surgical interventions, including 4 disarticulations or amputations. The incidence of complications can be related to the age of ...
Eight patients, one male and seven females, with no pre-existing hypothalamic-pituitary disease, who developed symptoms of hypopituitarism following cranial irradiation for nasopharyngeal carcinoma were studied 5 years or more after radiotherapy. All were GH deficient. Four of the patients with no GH response during insulin tolerance tests (ITT) showed increased GH in response to synthetic human growth hormone releasing factor (GRF-44). Four patients had impaired cortisol responses to ITT, and gradual but diminished cortisol responses to ovine corticotrophin releasing factor (CRF-41). There was no significant difference between mean peak increments in response to ITT and those in response to CRF-41. TSH responses to TRH were delayed in five and absent in two patients; four of these had low free T4 index. Prolactin was raised in all seven women and increased further in response to TRH. Two patients had impaired gonadotrophin responses to LHRH. None of the patients ...
Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10"4 man Sv. (Namekawa, K.).
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable ...
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is also applicable to ...
Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...
Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both CEBR and IMRT ...
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission ...
Radiation-induced enteritis is a well-recognized sequel of therapeutic irradiation. Therefore we examined the radioprotective properties of Punica granatum peel extract (PPE) on the oxidative damage in the ileum. Rats were exposed to a single whole-body X-ray irradiation of 800 cGy. Irradiated rats were pretreated orally with saline or PPE (50 mg/kg/day) for 10 days before irradiation and the following 10 days, while control rats received saline or PPE but no irradiation. Then plasma and ileum samples were obtained. Irradiation caused a decrease in glutathione and total antioxidant capacity, which was accompanied by increases in malondialdehyde levels, myeloperoxidase activity, collagen content of the tissue with a concomitant increase 8-hydroxy-2'-deoxyguanosine (an index of oxidative DNA damage). Similarly, pro-inflammatory cytokines (TNF-?, IL-1? and IL-6) and lactate dehydrogenase were elevated in irradiated groups as compared to control. PPE treatment reversed ...
Little clinical evidence has been provided to show the minimization of radiation resistance of tumors using high linear energy transfer radiation. We therefore investigated the radiobiological and molecular pathological aspects of carbon beam therapy. A total of 27 patients with squamous cell carcinoma (SCC) of the cervix were treated using a carbon beam and 50 control patients with SCC of the cervix using a photon beam. The expression of Ki-67, p53, and p27 proteins before radiotherapy and 5 and 15 days after therapy initiation were investigated using immunohistochemistry. Similar changes were observed in Ki-67 labeling index (LI) and p53 LI during carbon and photon beam therapies. However, for carbon beam therapy, the mean p27 LI significantly decreased from 25.2% before treatment to 18.6% on the 5th day after treatment initiation, followed by a significant increase to 36.1% on the 15th day. In contrast, for photon beam ...
INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...
Dosimetry parameters such as deposition, clearance, retention, and translocation and dissolution of inhaled particles in and to different lung compartments may be important for the persistence of particles...Full Text Available
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...
Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of SNL/California`s Environmental Monitoring Program, an ...
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...
Reactor pressure vessel (RPV) steels are subjected to neutron irradiation at a temperature of about 290 deg C. This radiation exposure alters the mechanical properties, leading to a shift of the brittle-to-ductile transition temperature toward higher temperatures and to a diminution of the rupture energy as determined by Charpy V-notch tests. This radiation embrittlement is one of the important aging factors of nuclear power plants. U.S. NRC recommended the basic requirements for the determination of the pressure vessel fluence by regulatory guide DG-1025 in order to reduce the uncertainty in the determination of neutron fluence calculation and measurements. The determination of the pressure vessel fluence is based on both calculations and measurements. The fluence prediction is made with a calculation and the measurements are used to qualify the calculational methodology. Because of the importance and the difficulty of these calculations, the ...
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. Additionally in the 2nd series ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex ...
Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials and Methods: HT-29 ...
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. (2004), aimed to the Sc-Sp separation. This ...
Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event free (EFS) and overall survival rates from multi-disciplinary therapy in Ewing's Sarcoma (ES). Materials and Methods: Between 1983 and 1988, 184 children with ES were enrolled onto POG 8346. 178 (97%) met eligibility criteria; 6 had non-ES pathology. Induction treatment of Cyclophosphamide/Adriamycin (C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy (XRT) and C/A, Dactinomycin and Vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. 40 patients were randomized to receive SF, whole bone XRT to 39.6 Gy plus a 16.2 Gy boost (total 55.8 Gy) or IF to 55.8 Gy while 84 were assigned to IF XRT. Results: Of 179 ...
Studies begun during the first year of this project on biopsies from spontaneous tumors in dogs and from human patients undergoing radiotherapy treatment were continued. The results indicate that significant fractions of the spontaneous tumors in dogs and cervical carcinomas in patients undergoing radiotherapy have a DNA content higher than normal diploid cells. The higher DNA content in tumor cells permits distinguishing them from normal cells in the biopsy material with the aid of flow microfluorometric (FMF) instrumentation or multiangle light-scatter spectrometry.
Purpose: To conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer. Patients and Methods: Between March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data. Results: There was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences in the radiotherapy group (24 solitary), but there was no significant difference in distant recurrence-free ...
PurposeTo conduct a retrospective analysis within a large university teaching hospital, comparing outcomes between patients receiving either radical surgery or radiotherapy as curative treatment for bladder cancer.Patients and MethodsBetween March 1996 and December 2000, 169 patients were treated radically for muscle-invasive bladder cancer. Data were collected from patient notes. Statistical analyses were performed using Kaplan-Meier methods and Cox proportional hazards regression analysis to compare radiotherapy and surgical outcome data.ResultsThere was no difference in overall, cause-specific, and distant recurrence-free survival at 5 years between the two groups, despite the radiotherapy group being older (median age, 75.3 years vs. 68.2 years). There were 31 local bladder recurrences...
Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 #+-# 4.6 months, compared with 5.1 #+-# 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)
The objective of this project was to implement a centralised data base of internal quality control in radiotherapy according to the criteria of the decree of A.f.s.s.a.p.s. (French agency of sanitary safety of health products on 27 july 2007, about the internal quality control of external radiotherapy facilities. The software on one year meets the objectives: compliance by comparison with A.f.s.s.a.p.s. criteria but particularly optimization of the centralisation and analysis of the internal quality controls. (N.C.)
This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving ...
Iron is one of the main constituents of stainless steel which is used as a structural material in nuclear reactors. In fast and conceptual fusion and fusion-fission hybrid systems the primary energy range of neutron interaction lies between 1 and 20 MeV which opens up several reaction channels. The reaction cross-sections in this energy range are important for dosimetry, radiation damage, neutronics and safety studies of nuclear reactors. Keeping this in view Nuclear Data Section of the International Atomic Energy Agency has sponsored a Research Co-ordination Programme on Methods for the Calculation of Fast Neutron Nuclear Data for Structural Elements. Under this programme we propose to study (n,n'), (n,2n), (n,3n), (n,p), (n,np), (n,pn), (n,#alpha#), (n,n#alpha#), (n,#alpha#n) and (n,#gamma#) reaction cross-sections. Besides these, total, elastic and discrete level inelastic scattering cross-sections, angular distributions of neutron ...
Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a heterogeneous medium consisting of bone, soft tissue, lung, air ...
Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at Vindija Cave, a key archaeological site in central Europe that contains a 12 m-thick ...
Several short-lived, high-energy beta emitters are being proposed as the radionuclide components for molecular-targeted potential cancer therapeutic agents. The laboratory mice used to determine the efficacy of these new agents have organs that are relatively small compared to the ranges of these high-energy particles. The dosimetry model developed by Hui et al. was extended to provide realistic beta-dose estimates for organs in mice that received therapeutic radiopharmaceuticals containing 90Y, 188Re, 166Ho, 149Pm, 64Cu, and 177 Lu. Major organs in this model included the liver, spleen, kidneys, lungs, heart, stomach, small and large bowel, thyroid, pancreas, bone, marrow, carcass, and a 0.025-g tumor. The study as reported in this paper verifies their results for 90Y and extends them by using their organ geometry factors combined with newly calculated organ self-absorbed fractions from PEREGRINE and MCNP. PEREGRINE and MCNP agree to within 8% for the worst-case ...
By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO{sub 4}) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using {sup 60}Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the artificially irradiated sample and in both cases, ...
By the use of thermoluminescence (TL) technique we have investigated the effects of gamma irradiation on the TL response of pulverised natural zircon (ZrSiO_4) crystals from the Jos Plateau area of Nigeria. Samples of the mineral that have been previously annealed were artificially irradiated to moderate gamma doses ranging from 0.7 to 4.9 Gy using "6"0Co gamma-source of the CERD. The natural TL glow curve of the sample showed a broad peak around 250 deg. C, the peak was however, found to be completely erased following heat treatment for 2 h at 400 deg. C. The TL glow curves of the artificially irradiated samples showed two overlapping glow peaks at about 112 deg. C (peak I) and at 156 deg. C (peak II) within the dose range utilised. We note that the natural TL peak appears to be different from the two observed in the artificially irradiated sample. The TL response with dose was investigated for the two glow peaks found in the artificially irradiated sample and in both cases, in the ...
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total biological response rate is ...
Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using ...
Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software also allows the isodose visualization at the surface plan. The ...
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...
Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, dose-volume histograms (DVHs), the mean lung dose (MLD) and the ...
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a ...
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of ...
BackgroundThe purpose of this study was to analyze the radiotherapy (RT) quality assurance (QA) assessment in Japan Clinical Oncology Group (JCOG) 0202, which was the first trial...Full Text Available
Lysozyme chloride was administered to 84 patients of laryngeal cancer and the clinical effect was discussed. Lysozyme chloride delayed the appearance of swelling and white plaque while it accelerated that of inflammatory erythema in radiotherapy. No difference of the local inflammation was found between lysozyme administered groups and not administered groups when irradiation and chemotherapy were combined. Any side effect was not seen in blood picture of all cases by using lysozyme chloride.
The authors describe their experience of endocavitary radiotherapy of adenomas and carcinomas of the lower rectum. The method is an alternative for patients who cannot undergo standard surgical procedure or do no want a permanent colostomy. This method is cheap, fast and causes little discomfort to the patients, gives reasonable long-term results and has low morbidity. 11 refs., 4 figs., 2 tabs.
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. ...
In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be measured by a ...
Twenty-seven histologically confirmed cases of localised Ewing's sarcoma were treated by two different regimes. Radiotherapy alone was used in 13 cases and a combination of chemotherapy and radiotherapy in 14. Single agent chemotherapy (cyclophosphamide) was given sequentially in nine patients and cyclophosphamide and actinomycin-D in five. There is a significant difference in the response to these different regimes. Only 69.2% of patients treated by radiotherapy alone were disease-free, for a median period of 10.4 months and metastases were noticed in 53.8% of cases. The disease-free survival in patients treated by combination therapy (radiotherapy and chemotherapy) was 18.4 months and metastases were seen in only 42.9%. However, no metastases were seen in patients who received cyclophosphamide and actinomycin-D, during a period of 14 months and only one patient showed residual disease. It is concluded ...
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).
Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.
Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)
This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 17
Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available
There is increasing concern for the potential adverse health effects of human exposures to chemical mixtures. To better understand the complex interactions of chemicals within a mixture, it is essential...Full Text Available
To evaluate the predictive factors for treatment response and prognostic factors affecting survival outcomes after concurrent chemoradiotherapy (CCRT) for patients with anal squamous cell carcinoma. Medical records of forty two patients with histologically confirmed analsquamous cell carcinoma, who had complete CCRT between 1993 and 2008, were reviewed retrospectively. Median age was 61.5 years (39-89 years), and median radiotherapy (RT) dose was 50.4 Gy (30.0-64.0 Gy). A total of 36 patients had equal to or less than T2 stage (85.7%). Fourteen patients (33.3%) showed regional nodal metastasis, 36 patients (85.7%) were treated with 5-fluorouracil (5-FU) plus mitomycin, and the remaining patients were treated by 5-FU plus cisplatinum. The median follow--up time was 62 months (2-202 months).The 5-year overall survival, locoregional relapse-free survival, disease-free survival, and colostomy-free survival rates were 86.0%, 71.7%, 71.7%, 78.2%, respectively. Regarding ...
Purpose: To identify results and prognostic factors on long-term survival and local control following treatment of localized Ewing's sarcoma. Patients and Methods: Between 1979 and 2004, a total of 60 children and young adults with Ewing's sarcoma were treated. Patients with distant metastases at presentation (n = 6) and recurrent cases (n = 2) were excluded from this analysis. Patients were exclusively treated within ongoing national and international protocols CESS-81, CESS-86, EICESS-92, EURO-EWING-99. All patients received local irradiation with a total dose of 45-60 Gy; in addition, 41 (79%) of the patients had local surgical procedures, 27 (52%) of them with clear margins. Results: Overall survival rates at 5 and 10 years were 56% and 45%, respectively. Patients #<=# 14 years at diagnosis had overall survival rates of 66% and 61% at 5 and 10 years compared to older patients with corresponding survival rates of 47% and 31%, respectively (p = 0.05). Patients with tumors of lower ...
Optimal design of the hyperfractionated radiotherapy requires basic radiobiological data such as the critical dose per fraction, number of fractions per day and total equivalent dose, to name a few. As a prelude to in vivo hyperfractionated irradiation, the authors carried out experiments to determine quantitative changes in the proliferation and cell kinetic parameters of multicellular spheroids after hyperfractionated irradiation. Experiments were carried out with HeLa S-3 spheroid growing in MEM culture media. Hyperfractionated irradiation schedules were 1.5 Gy/f, 2f/day and 1.0 Gy/f, 3 f/day. At intervals after irradiation, cell numbers, growth delays and cell cycle distribution of spheroids were determined. The kinetic data were obtained by the use of flow cytometry. The most pronounced changes in cell kinetic parameters were early G/sub 2/M block, proportional to single radiation dose up to 4.0 Gy. There was a corresponding depletion of ...
Background and purpose: We evaluate the feasibility of concomitant and adjuvant docetaxel combined with three-dimensional conformal radiotherapy (3D-CRT) and androgen deprivation in high-risk prostate carcinomas. Methods: Fifty men with high-risk localized prostate cancer (16), locally advanced (28) or very high-risk prostate cancer (6) were included. Seventy Gy were delivered on prostate and seminal vesicles in 35 fractions, concurrently with weekly docetaxel (20 mg/m"2). Three weeks after the completion of 3D-CRT, docetaxel was given for 3 cycles (60 mg/m"2), every 3 weeks. Patients had to receive LHRH agonist during 3 years. Results: The intent to treat analysis shows that four patients out of 15 stopped prematurely the chemotherapy due to grade 3-4 acute toxicity. In the per protocol analysis, 46 patients completed a full-dose chemoradiation regimen representing 413 cycles: five patients experienced a grade 3 toxicity, and 15 patients experienced a grade 2 ...
A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex ...
Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).
The recent definition of a postulated thermal shock accident followed promptly by system repressurization, termed an overcooling or pressurized thermal shock accident, has set a large analysis and research effort into motion. The essential elements are concerned with defining the accident transients, evaluating the instrumentation and controls that cause the postulated accidents, and evaluating the metallurgical and structural mechanics aspects of the reactor vessel with respect to its failure potential. This paper poses the question faced by the Nuclear Regulatory Commission (NRC) for the vessel steel embrittlement, annealing, and surveillance dosimetry facets of this postulated accident and provides information on our plans for study of this problem as well as current status.
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular ...
Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.
The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. [Italian] L'integrazione delle immagini diagnostiche aventi diverso contenuto informativo anatomico-funzionale puo' essere utilizzata nella radioterapia per migliorare le procedure diagnostiche e ottimizzare la geometria dell'irraggiamento. I sistemi per l'elaborazione di piani di radioterapia oggi in uso sono direttamente interfacciati con gli apparecchi di Tomografia Computerizzata (TC) e ...
High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. ...
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
The evaluation of radiotherapy and surgery as exclusive local treatment in comparably selected subgroups of patients with Ewing's sarcoma on the basis of the CESS 86-data. In the German multicenter Ewing's sarcoma study CESS 86, treatment consisted for four 9-week-courses of VACA- or VAIA-chemotherapy plus local therapy. VACA (vincristine, actinomycin D, cyclophosphamide, adriamycin) was given in low-risk extremity tumors with a tumor volume below 100 cm"3. Highrisk patients with central lesions or a tumor volume >100 m"3 received VAIA (ifosfamide instead of cyclophosphamide). Local therapy started after one complete chemotherapy course in week 10. Based on an individual decision in each patient, local therapy was either radical surgery or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy. Because of poor results with radiotherapy in a preceeding study, it was intended to restrict ...
Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for reference fields and ...
Angiosarcoma (AS) is a rare and aggressive vascular neoplasm with very poor prognosis. Patients with extensive cutaneous AS who are not surgical candidates have very limited options since there is no...Full Text Available
This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available
The document reports the main issues discussed during the first course-debate on quality controls in radiotherapy, held in Rome in December 3-4, 1998 and May 3-5 1999 in collaboration between the Istituto Superiore di Sanita' and the Istituto Regina Elena. The points considered critical to the quality assurance in radiotherapy by the participants are presented in relation to the total radiotherapy procedure. [Italian] Questo documento e' dedicato al primo corso-dibattito sui controlli di qualita' in radioterapia svoltosi a Roma il 3-4 dicembre 1998 e il 3-5 maggio 1999 in collaborazione tra l'Istituto Superiore di Sanita' e l'Istituto Regina Elena. Esso presenta gli argomenti ritenuti critici per l'assicurazione di qualita' in radioterapia in relazione all'intera procedura radioterapica, in base alle esperienze dei partecipanti.
PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available
Background:The non-surgical management of non-melanoma skin cancers is an area requiring clinical investigation. Radiotherapy has a role in treatment for a defined subset...Full Text Available
Bone metastases at the thoracic and lumbar segment of the spine are usually presented with painful sensation and medullar compression. The treatment is based on the clinical and neurological conditions of the patient and the degree of tumor invasion. In the present study, 32 patients with spinal metastasis of thoracic and lumbar segment were prospectively analyzed. These patients were treated by decompression and internal stabilization followed by radiotherapy or irradiation with external immobilization. The election of the groups was in accordance with the tumor radiotherapy sensitivity, clinical conditions, spinal stability, medullar or nerve compression and patient's decision. The Frankel scale and pain visual test were applied at the moment of diagnosis and after 1 and 6 months. The surgical group had better results with preserving the ambulation longer and significant reduction of pain.(author)
The aim of this study is to develop an Automatic Post-processing Tool for four-dimensional (4D) treatment planning (APT4D) that enables the user to perform some necessary procedures related...Full Text Available
Between 1973 and 1978 combined radiotherapy and chemotherapy were given to 22 patients with histologically proven Ewing's sarcoma. The combined chemotherapy consisted of cyclophosphamide, vincristin, adriamycin, as well as dacarbazine in some cases. The neoplasm was a localized one at the beginning of treatment in 14 of the 22. These patients received high-voltage rediotherapy to the primary focus at a focal dose between 42 and 55 Gray (4200-5500 rad), followed by chemotherapy. After 6-8 treatment cycles, adriamycin was replaced by methotrexate. Nine of the 14 patients survived without recurrence for 12 to over 59 months. Eight patients had extensive metastases at the beginning of treatment: they at first received only chemotherapy, followed by radiotherapy or operation, as indicated. Full clinical remission was achieved in five of them: in three this remission has now lasted for more than 18, 40 and 44 months, respectively. These results ...
Hepatocellular carcinoma (HCC) is one of the most critical global health issues. With frequent association of viral liver disease, HCC is highly complex, harboring both cancer and chronic liver disease....Full Text Available
Rectum reference dose points have a direct impact on the morbidity seen in gynecological intracavitaty radiotherapy. The aim of this study is to obtain less morbidity by marking rectum with radio opaque solution. Fourteen patients with gynecological cancer who underwent external radiotherapy received 15 Gray (Gy) intracavitary radiotherapy. During the internal radiotherapy planning, radio opaque solution has been administered into the rectum to observe it on lateral radiogram. Thus rectum reference dose point and five points were marked at sites nearest to the sources. Nucletron Planning system was used for obtaining three-dimensional planning. After therapy patients were followed at every three months. Median follow-up was 18 months. Most frequently observed morbidities were grade 1-2 rectitis and cystitis in six patients. As a result, more accurate rectum dose values and less factors causing dose ...
Based on the assumption that an accelerated proliferation process prevails in tumour cell residues after surgery, the possibility that treatment acceleration would offer a therapeutic advantage in postoperative...Full Text Available
PurposeWe previously reported a randomized phase II clinical trial combining a poxvirus-based vaccine encoding PSA with radiotherapy in patients with localized prostate...Full Text Available
Aim: To systematically review the currently available high quality evidence evaluating treatments for moist desquamation in radiotherapy patients. Design: Systematic literature review. Methods: Electronic databases, websites, reference lists, key journals and conference proceedings were searched. Attempts were also made to uncover unpublished material. Relevant studies proceeded to data extraction and quality assessment. Results: Twenty studies were found; 10 were eligible for inclusion. Although many studies were small, none had unacceptably poor quality. No meta-analysis was undertaken as the studies were not homogenous in their interventions or methods. No convincing evidence for any intervention was found. Conclusion: Despite being recommended by many guidelines (College of Radiographers Summary of Intervention for Acute Radiotherapy Induced Skin Reactions in Cancer Patients (London, 2001); NHS Quality Improvement Scotland Best Practice ...
Combined treatment of 131 patients aged 3-16 with local form of Ewing's sarcoma is carried out. Survival rate per year was studied in patients without diagnosed metastases depending on chemiotherapy method. It is stated that improved results of treatment of children with Ewing's sarcoma may be achieved by combining radiotherapy with long-term systemic polychemotherapy. The most efficient and expedient method of radiotherapy of long bone sarcoma in children is dialy three-field irradiation with 2 Gy at SFD to the tumor 60 Gy, and adjacent tissues - 40 Gy.
A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)
Radiotherapy recent development in cancer treatment needs strong procedures and quality assessment to improve safety both for patients and professionals. In Ile de France territory, a coordinated action between ASN inspectors and medical doctors specialized in public health (MISP), working as civil servants in health administration, was initiated at the end of 2007. An inspection guideline was implemented in a workshop between ASN and Regional Hospital Agency (ARH). The MISP as health administrator has to verify if care organisation responds to treatment cancer regulatory framework: as a doctor he is authorized to access to patient records to know which treatment was chosen. He has to assure if the therapeutic guidelines are respected. His comprehensive approach is essentially patient-oriented. The MISP inspection coordinated with ASN inspectors is a very pertinent pluri-disciplinary approach, undeniably necessary in such a medical technic. The effectiveness of the ...
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose calculation and flexible cost functions derived ...
Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients for motion-adapted ...
One of the refinements of modern Nuclear Medicine is the capacity of providing dynamic and kinetics images of the administered radiopharmaceutical, reproducing its transport mechanism, action sites, receptor binding and excretion route. With the continues technological advances new radiopharmaceuticals have been developed in order to express higher specificity and with higher characters of affinity between receptor/complex. One radiopharmaceutical is formed by a reagent or bio molecule that has in its structure a radioisotope, that has the objectives of carrying it to the organs of affinity or to benign or malign tumoral process. Somatostatin inhibits the growing and proliferation of several tumoral cells. Somatostatin analogs bind to somatostatic receptors that are expressed in different kind of neoplasia DOTA-LANREOTIDE (DOTALAN) is an octapeptide analog to somatostatin. The interest of labeling the bio conjugate with gallium-67 in Nuclear Medicine comes from its physical, chemical ...
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
Purpose: To evaluate the importance of surgical margins for local and systemic control of Ewing's sarcoma family tumors (ESFT). Methods and Materials: Between 1979 and 1999, 512 patients with ESFTs entered 4 different adjuvant and neoadjuvant studies performed at a single institution. Of these patients, 335 were treated with surgery alone (196) or surgery followed by radiotherapy at doses of 44.8 Gy (139). We compared their outcome with that of the 177 patients who were locally treated by radiotherapy at 60 Gy. Results: Local control (88.8% vs. 80.2%, p < 0.009) and 5-year disease-free survival (63.8% vs. 47.6%, p < 0.0007) were significantly better in patients treated with surgery and, among them, in those with adequate surgical margins (96.6% vs. 71,7%, p < 0.0008, and 69.6% vs. 46.3%, p < 0.0002). Nonetheless, better results were observed only in extremity tumors. Conclusions: Surgery is better than ...
Background and purpose: To assess the effectiveness of radiotherapy in preventing tumour seeding after chest drain or pleural biopsy in patients with malignant mesothelioma and to determine, if tract metastases appear, whether they are tender or troublesome to patients. Patients and methods: Patients with a histological diagnosis of pleural mesothelioma and an invasive procedure within the preceding 21 days were stratified by age, performance status and treatment centre. Randomisation was performed between immediate drain site radiotherapy 21 Gy in three fractions (XRT arm) or best supportive care (BSC) with follow-up to 12 months. Patients were asked to complete questionnaires on treatment toxicity and on symptoms from any tract metastases detected. Results: Sixty-one patients were recruited from two centres between 1998 and 2004; 56 men, 5 women, median age 70. 31 were allocated to drain site radiotherapy. Seven patients ...
Fiber optic metrology developed at the CEA LIST laboratories involves fiber Bragg grating sensors, distributed Brillouin optical time domain reflectometry and optically stimulated luminescence dosimetry. Recent activities in optical fiber sensing are reviewed from laboratory experiments to field trials.
Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 Rad dose would still be ...
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
A short synopsis of each project is given covering the following main areas of research and development: Atmospheric sciences; Biotechnology; Chemical and instrumentation analysis; Computer and information science; Design and manufacture engineering; Ecological science; Electronics and sensors; Experimental technology; Health protection and dosimetry; Hydrologic and geologic science; Marine sciences; Materials science; Nuclear science and engineering; Process science and engineering; Sociotechnical systems analysis; Statistics and applied mathematics; and Thermal and energy systems.
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
Topics of this proceedings are: DNA damage and repair; Space research; Cell and tissue radiobiology; Treatment planning 1: The role of clinical RBEs; Treatment planning 2: Dose optimization and inverse planning; Dosimetry; Clinical results of particle therapy and new techniques; Status reports and future developments. Separate abstracts were prepared for 79 chapters. (orig./SR)
The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).
The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This preliminary results suggest that TCIR with I-131 ...
Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)
We present our initial experience with a new biodegradable (BD) esophageal stent in two patients, one for a therapy-resistant benign esophageal stricture, and the other as a temporary measure during curative radiotherapy for oesophageal carcinoma. The BD stents need to be loaded into a conventional pull-back delivery system but are then placed in a standard fashion. Pre-dilatation should be avoided to reduce the risk of migration, however if migration occurs the stents can be left to dissolve in the stomach. The stents are radiolucent but easily identified on CT with minimal artefact and thus might even aid with radiotherapy planning. BD stents offer an exciting new strategy for therapy-resistant benign strictures as well as a supportive measure for oesophageal cancer undergoing non-surgical treatment. (orig.)
During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose "kernels" partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even furt...
Local control of Ewing's sarcoma was analysed in a series of 67 patients treated by surgery and/or radiotherapy as well as combination chemotherapy. Radiotherapy was employed with or without surgery in 60 patients and produced an overall local control rate of 55%; complete excision of the primary lesion seemed to be beneficial. There was a marked variation in control rates depending on the site of the primary lesion: limb 85%, rib 53%, pelvis 31% and other sites 33%.Primary tumours greater than 10 cm in diameter were significantly less likely to be controlled. Using daily fractions of approximately 180 cGy, total doses in excess of 6000 cGy seem more likely to produce serious late morbidity amd may not increase the local control rate. No cases of second malignancy arising in irradiated tissue have been observed to date, but one patient developed acute lymphoblastic leukaemia. (author).
The behaviors of peripheral eosinophils during radiotherapy were examined in 200 cases of non-resected cervical cancer. Before irradiation, the mean absolute eosinophil count had been 170 +- 168/mm_3, and eosinophilia (more than 500/mm_3) had been observed in 11 cases (5.5%). Postirradiation eosinophilia occurred in 126 cases (63%). The mean period between institution of irradiation and the peak of the eosinophil count was 27.8 days. The mean highest eosinophil count was 691 +- 437/mm_3, and the mean bone marrow dose in this period was 906 rad. Comparisons of the eosinophil count according to the stage showed no significant differences. (Chiba, N.).
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).
This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...
Multiple myeloma is a highly radiosensitive skeletal malignancy, but bone-seeking radionuclides have not yet found their place in disease management. We previously reported that the proteasome inhibitor...Full Text Available
Hyperthermia (HT) is a strong adjuvant treatment with radiotherapy and chemotherapy because it causes tumor reoxygenation. However, the detailed molecular mechanisms of how HT enhances tumor oxygenation...Full Text Available
33 patients with advanced malignant melanoma were studied after intravenous administration of 131I-labeled Fab fragments specific for p97, an oncofetal glycoprotein of human melanoma. In all, 47 gamma...Full Text Available
The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to the Planning Target Volume (PTV, ICRU 50) ...
A review of main issues in diagnosing, complex treatment and prognosis of Ewing's sarcoma is presented. Current trend in chemotherapy, radiotherapy and surgery of the disease is discussed. Unfavourable prognosis is attributed to the systematic character of the disease, necessitating a complex therapeutic approach. Attempts to make an optimal combination of the three therapeutic methods in order to improve survival and reduce the rate of post-treatment complications are analyzed. 37 refs., 4 tabs. (author).
The purpose of this study was to investigate if interfraction and intrafraction motion in free-breathing and gated lung IMRT can lead to systematic dose differences between 3DCT and 4DCT. Dosimetric...Full Text Available
PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available
The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed doses n the range ...
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
The study had three objectives: to collect information that explain the impact of the Aube storage center (C.S.A.) on environment and allow to evaluate the consequences for man, secondly, to build a referential for any future inquiry or follow-up, thirdly, to allow to the local commission of information to elaborate an information towards the side residents and local actors that take into account their questions. Trees, waters, sediments, soils, grass, products of gardens and vineyards were the object of sampling, their dosimetry is given in this report. Other dosimetry measures were made along the nuclear site and the results are equally in this report. (N.C.)
Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
Nuclear forensics is the analysis of nuclear materials recovered from either the capture of unused materials, or from the radioactive debris following a nuclear explosion and can contribute significantly to the identification of the sources of the materials and the industrial processes used to obtain them. In the case of an explosion, nuclear forensics can also reconstruct key features of the nuclear device. Nuclear forensic analysis works best in conjunction with other law enforcement, radiological protection dosimetry, traditional forensics, and intelligence work to provide the basis for attributing the materials and/or nuclear device to its originators. Nuclear forensics is a piece of the overall attribution process, not a stand-alone activity
A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)
This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.
Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.
Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).
The rapid growth in the use of in vitro methods for nanoparticle toxicity assessment has proceeded with limited consideration of the unique kinetics of these materials in solution. Particles in general and nanoparticles specifically, diffuse, settle and agglomerate in cell culture media as a function of several systemic and particle factors: media density and viscosity, particle size, shape and density. Cellular dose then is also a function of these factors as they determine the rate of transport of nanoparticles to cells in culture. Here we develop and apply the principles of particokinetics and dosimetry in vitro and outline an approach for simulation of nanoparticle particokinetics in cell culture systems. We illustrate that where equal mass concentrations (?g/ml) imply equal doses for dissimilar materials, the corresponding particle number or surface area concentration doses differ by orders of magnitude. When rates of diffusional and gravitational particle ...
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...
... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...
This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new cold neutron source (CNS), the assessment of beam tube changes on the anticipated pressure vessel lifetime, ...
The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...
Automatic segmentation of anatomical structures in medical images is a valuable tool for efficient computer-aided radiotherapy and surgery planning and an enabling technology for dynamic adaptive radiotherapy. This paper presents the design, algorithms and validation of new software for the automatic segmentation of CT images used for radiotherapy treatment planning. A coarse to fine approach is followed that consists of presegmentation, anatomic orientation and structure segmentation. No user input or a priori information about the image content is required. In presegmentation, the body outline, the bones and lung equivalent tissue are detected. Anatomic orientation recognizes the patient's position, orientation and gender and creates an elastic mapping of the slice positions to a reference scale. Structure segmentation is divided into localization, outlining and refinement, performed by procedures with implicit ...
The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).
The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.
Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For malignant melanoma, 1000 rads at a time, ...
To define the prognostic factors after surgical resection and evaluate the effectiveness of Post Operative Radiotherapy (PORT) in cases with cholangiocarcinoma, 44 cases with proximal cholangiocarcinoma were examined. The mean observation period was 20.6 months, and the survival rates 1, 3 and 5 years after the resection were 79.9%, 59.8% and 39.3%, respectively. Univariate analysis revealed that the presence of lymph node metastasis and absence of PORT were significant poor prognostic factors. Multivariate analysis revealed that the absence of PORT was a significant poor prognostic factor. The survival rates for 1 and 3 years after the resection were 80.0% and 40.0% in the curable A/B and PORT (-) group, and 100% and 53.3% in curable C and PORT (+) group. There were no local reccurences in the pathologically classified hm2 and em2 patients who underwent PORT. Even when the surgical margin is positive for the carcinoma pathologically, it is possible to avoid local ...
The present study was undertaken in 27 children with localized Ewing's sarcoma treated at our hospital. In 9 cases the lesion was central and in 18 peripheral. Treatment consisted of: 1) Chemotherapy with 6 drugs (vincristine, cyclophosphamide, methotrexate, bleomycin, dactinomycin and doxorubicin) for one year in all patients; 2) Radiotherapy in 24 patients at a dose of 30-40 Gy in the entire bone with a booster dose of 10-15 Gy in the lesion. In 7 patients debulking surgery was performed followed by irradiation. Two cases with tumor in expendable bones and one with extensive destructive lesion in the tibia underwent radical surgery. One patient suffered local recurrence (femur) and 6 developed distant metastases. The remaining 20 (74%) patients were alive and tumor-free after follow-up periods of 17-80 months. Among the 12 patients with extremity lesions who were alive, 7 (58%) had minimal or mild treatment sequelae, 2 moderate, and 3 severe sequelae but no ...
From December 1981 to September 1986, 149 patients were treated at the Radiotherapy Department of the Hospital Clinico y Provincial of Barcelona by means of intracavity irradiation with 137 cesium high 1 sources and 2. To 112 of the total number of patients external radiotherapy to the whole of the pelvis using photons of 6 MeV was also administered. A total of 46 (30.7%) patients presented rectal complications. The rectitis observed was mild in 16 cases (10.7%), moderate in 15(10%) and severe in 15(10%). The 15 patients with severe rectitis had to be treated by unloading colostomy. In patients with severe complications, the maximum total rectal dose administered was between 5,855 and 9,490 cGy, and the maximum rectal dose administered via curietherapy was 1,055 to 7,320 cGy. Maximum total rectal dose administration greater than 4,000 cGy and maximum rectal dose administered via curietherapy greater than 5,800 cGy were statistically significant ...
In 1981, the German Society of Pediatric Oncology initiated a multi-institutional study for the treatment of Ewing's sarcoma. The protocol (Cooperative Ewing's Sarcoma Study, CESS 81) consisted of four courses of a four-drug-regimen (VACA), each course taking nine weeks. Local therapy (radical surgery or resection plus irradiation or radiotherapy alone) was performed after the second course. The results of CESS 81 can be summarized as follows: VACA-chemotherapy is effective in controlling systemic disease. Initial tumor mass and response to initial chemotherapy are of major prognostic value for local control and survival. Permanent local control is a problem, especially in irradiated patients. The high local failure rate in irradiated patients in CESS 81 could be attributable to the following reasons: Late start of local therapy (after 18 weeks of chemotherapy), uneven distribution of prognostic parameters: Large tumors were more often irradiated than operated, ...
From 1964 to 1973 at the Institute of Oncology and Radiobiology, Havana City, 18 clinical histories were studied, all of them from patients with Erwing's sarcoma, histologically diagnosticated by biopsy. Age, sex, race, traumatism background, hemogram disturbances, radiographic signs, primary tumor localization, and early treatment, were exposed. Early treatment in 14(83%) patients as radiotherapy. Local recurrence or metastasis was presented in 10(55,5%) patients during the two first years following attack treatment. Five (35,7%) patients was the survival rate within five years starting early treatemt. After five years, three (21,4%) patients were alive: for 18 and 14 year, and 64 month period; two patients died at 62 and 64 months. It is concluded that this survival may be increased by initial behaviour enclosed at the technologic therapeutic patterns of the the Institute of Oncology and Radiobiology, of Havana City. (author).
Over 300 cases of femoral neck fractures following radiotherapy for intrapelvic malignant tumor have been reported in various countries since Baensch reported this disease in 1927. In Japan, 40 cases or so have been reported, and cases of bilateral femoral neck fractures have not reached to ten cases. The authors experienced a case of 75 year-old female who received radiotherapy for cancer of the uterus, and suffered from right femoral neck fracture 3 months after and left femoral neck fracture one year and half after. As clinical symptoms, she had not previous history of trauma in bilateral femurs, but she complained of a pain in a hip joint and of gait disturbance. The pain in left femoral neck continued for about one month before fracture was recognized with roentgenogram. As histopathological findings, increase of fat marrow, decrease of bone trabeculae, and its marked degeneration were recognized. Proliferation of some blood vessels was ...
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
The radiotherapy is the prime treatment for the cavum cancer. It is also useful to treat the tumor recurrences, in this case the reirradiation stays the only efficient therapy option to give a correct local control. The reirradiation, exclusive or in association with other therapies can contribute to the local control of cavum cancer recurrences with a survival rate at five years of 36 to 58%. (N.C.)
It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.
A compact medical synchrotron is being developed which aims to promote the advanced radiotherapy based on the accelerator. As it is small-sized, a high field dipole magnet of 3 T at 200 kA is used. It is excited by the discharge current of the capacitor bank of which waveform is half sinusoidal. To provide with the flat field of 10 - 20 #mu#s duration for the multi-turn injection an additional power supply is developed. For the quadrupole magnet a 100 kHz switch-mode power supply is adopted as it requires the fine tuning and accurate field tracking to the dipole field. (author)
Three cases of primitive suprasellar germinomas are reported: the tumors show typical clinical signs (diabetes insipidus, disfunctions), but CT findings are not so specific. It is very important to reach a correct diagnosis based on clinical and radiological findings, because of very high radiosensibility of the tumor. The accuracy of preoparative diagnosis has been enhanced by CT in addition to conventional neuroradiological examinations. Due to the possible risk of meningeal spreading following biopsy, some authors prefer to avoid biopsy and to treat directly the patient by radiotherapy; a rapid reduction of the tumor size at the dose of 30 Gy suggest a possible germinoma.
A computer-assisted rotation and stationary conformation radiotherapy system with overrunning multileaf collimators has been developed. This system can produce any shape of target volume, including a number of target areas outside the axis of the rotation, regardless of the location of the axis at 360"0 rotation irradiation. In addition, by changing the dose rate and deleting a partial region within a field, multiple stationary irradiation can produce more homogeneous target volumes - thus avoiding excessive irradiation to critical organs - than the rotation technique. (orig.).
We report the case of a 22-year-old man with Ewing's sarcoma who attained a complete remission (CR) after combination radiotherapy and chemotherapy. Secondary acute lymphoblastic leukemia with multiple cytogenetic abnormalities involving chromosome 5 and 7 developed 16 years later. The patient underwent induction chemotherapy and entered a CR. Peripheral blood stem cell transplantation from a matched sibling was performed successfully and he is in complete remission of both ALL and Ewing's sarcoma. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...
A fast and accurate segmentation of organs at risk, such as the healthy colon, would be of benefit for planning of radiotherapy, in particular in an adaptive scenario. For the treatment of pelvic tumours, a great challenge is the segmentation of the most adjacent and sensitive parts of the gastrointestinal tract, the sigmoid and descending colon. We propose a semi-automated method to segment these bowel parts using the fast marching (FM) method. Standard 3D computed tomography (CT) image data obtained from routine radiotherapy planning were used. Our pre-processing steps distinguish the intestine, muscles and air from connective tissue. The core part of our method separates the sigmoid and descending colon from the muscles and other segments of the intestine. This is done by utilizing the ability of the FM method to compute a specified minimal energy functional integrated along a path, and thereby extracting the colon centre line between ...
Purpose: To evaluate the role of stereotactic radiosurgery (SRS) and whole-brain radiotherapy (WBRT) for the treatment of brain metastases in patients with renal cell cancer (RCC). Patients and methods: 88 patients were treated with either SRS (n = 51) or SRS + WBRT (n = 17) for one to three lesions, or with WBRT (n = 20) for more than three brain metastases. Overall survival (OS), intracerebral control (IC) and local control (LC) were retrospectively analyzed. Six potential prognostic factors were assessed: age, gender, number of brain metastases, extracerebral metastases, recursive partitioning analysis (RPA) class, and interval from tumor diagnosis to irradiation. Results: The median times for OS, IC, and LC from the time of diagnosis were 11, 9, and 10 months. The median OS times for SRS, SRS + WBRT, and WBRT were 12, 16, and 2 months. Addition of WBRT to the SRS improved IC (p = 0.032) but not OS (p = 0.703). On multivariate analyses, improved OS was ...
During the last few decades, accuracy in photon and electron radiotherapy has increased substantially. This is partly due to enhanced linear accelerator technology, providing more flexibility in field definition (e.g. the usage of computer-controlled dynamic multileaf collimators), which led to intensity modulated radiotherapy (IMRT). Important improvements have also been made in the treatment planning process, more specifically in the dose calculations. Originally, dose calculations relied heavily on analytic, semi-analytic and empirical algorithms. The more accurate convolution/superposition codes use pre-calculated Monte Carlo dose 'kernels' partly accounting for tissue density heterogeneities. It is generally recognized that the Monte Carlo method is able to increase accuracy even further. Since the second half of the 1990s, several Monte Carlo dose engines for radiotherapy treatment planning have been introduced. To ...
Purpose: Extrahepatic cholangiocarcinoma is a rare malignancy. Despite radical resection, survival remains poor, with high rates of local and distant failure. To clarify the role of radiotherapy with chemotherapy, we performed a retrospective analysis of resected patients who had undergone chemoradiotherapy. Methods and Materials: A total of 45 patients (13 with proximal and 32 with distal disease) underwent resection plus radiotherapy (median dose, 50.4 Gy). All but 1 patient received concurrent fluoropyrimidine-based chemotherapy. The median follow-up was 30 months for all patients and 40 months for survivors. Results: Of the 45 patients, 33 underwent adjuvant radiotherapy, and 12 were treated neoadjuvantly. The 5-year actuarial overall survival, disease-free survival, metastasis-free survival, and locoregional control rates were 33%, 37%, 42%, and 78%, respectively. The median survival was 34 months. No patient died ...
The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion radiotherapy has the advantage of dose distribution and biological ...
The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627
The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.
The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems
Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.
A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available
Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).
Analytical method of theoretical simulation of collective hydrodynamic instabilities of intensive flows of discrete radiators, interacting with each other only through the coherent fields of their spontaneous radiation in corresponding media was suggested...
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
The different radiation loads caused by natural and artificial radionuclides are compared in this paper. This examples will serve to illustrate that the problem of population exposure to radiation can only be solved in consideration of all components and to show which effects of the radiation from natural sources are of special importance in this connexion. (orig./AK).
The problem of optimizing a horn radiator of electromagnetic waves for the reflection coefficient and the coefficient of transformation of the fundamental mode into higher order modes is solved. Optimization is performed by means of selecting a combined shape of the radiator generatrices.
A meeting was held on October 15, 16, 17, 1990 to discuss the state of tritium safety and environmental effects. The meeting was organized with the help of the International Energy Agency planning committee consisting of K. Steinmetz, Y. Seki, G. Nardella, and G. Vivian. Representative of tritium production facilities and heavy water reactor power production were also involved. The meeting was organized to address seven topics in tritium safety that were thought to require further work. The topics were: (1) materials science, (2) environmental models, (3) environmental model validation, (4) tritiated organic compounds, (5) human dosimetry, (6) tritium sampling and measurement, and (7) long-term environmental databases.
Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.
The mission of the Health and Safety Research Division (HASRD) is to provide a sound scientific basis for the measurement and assessment of human health impacts of radiological and chemical substances. Our approach to fulfilling this mission is to conduct a broad program of experimental, theoretical, and field research based on a strong foundation of fundamental physical studies that blend into well-established programs in life sciences. Topics include biomedical screening techniques, biological and chemical sensors, risk assessment, health hazards, dosimetry, nuclear medicine, environmental pollution monitoring, electron-molecule interactions, interphase physics, surface physics, data base management, environmental mutagens, carcinogens, and tetratogens.
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...
Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)
An optical klystron is built in the 800 MeV electron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
By proposing the four-dimensional, reciprocity transformations the appropriate condition for superluminal electromagnetic Cerenkov radiation is obtained by introducing the hypothesis that tachyons possess vector energy and scalar momentum.
drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...
...References | Radiation Protection | US EPA This page provides links to the reference material on EPA's Radiation Protection Web site. U.S. EPA/...OAR/ORIA/Radiation Protection Division Jump to main content. Radiation Protection Contact Us Search: All EPA This Area You are here: EPA Home ... Radiation Protection References PageName Technical Users General Public Reporters Librarians Students/Teachers PROGRAMS TOPICS REFERENCES References The Reference Section provides general material that support the ...other sections of EPA's Radiation Protection Web site. You will find links within the information to related pages throughout the Radiation Protection , EPA ...
The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-{epsilon} model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to ...
Turbulent premixed methane-air combustion in a cylindrical chamber is numerically simulated considering radiation effect. Reaction rates are considered as minimum rates between Arrhenius rates and eddy break up rates. A five step reduced mechanism is used. Turbulent modeling is done via standard k-? model imposed by empirical inlet boundary conditions. Source terms of energy equation consist of reaction rates and radiation effects. The discrete ordinate method (DOM) is employed to solve the radiative transfer equation (RTE) and the weighted sum of gray gas model (WSGGM) is imposed to consider radiation effect of non-gray gases. The results indicate that in the case of turbulent combusting flows, the effect of radiation of gases can affect the temperature and species concentrations. The numerical results obtained considering radiation effect are closer to the ...
... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the ...
When energetic bunches of electrons traverse an undulator field, they can spontaneously emit radiation both coherently and incoherently. Although it has generally been assumed that undulator radiation is incoherent at wavelengths short compared to the longitudinal size of the electron bunch, several recent observations have proved this assumption false. Furthermore, the appearance of coherent radiation is often accompanied by a significant increase in radiated power. Here we report observations of strongly enhanced coherent spontaneous radiation together with direct measurements, using transition radiation techniques, of the electron distributions responsible for the coherent emission. We also report demonstrated enhancements in the predicted spontaneous radiated power by as much as 6x10"4 using electron bunch compression. copyright 1996 ...
... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...
... spontaneous radiation of amplifiers within a relatively w~de range of ... pulse widths are 20-30ns, while amplified spontaneous radiation pulse ...
Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around ...
The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
A formula is obtained which describes the kinetics of low-temperature radiation hardening caused by creation of dislocation loops of interstitial type during irradiation. The radiation hardening of aluminum and vanadium is estimated using this formula and results of experiments on studying processes of nucleation and growth of interstitial dislocation loops in these materials by transparent electron microscopy. It is shown that the proposed formula is valid for description of the kinetics of low-temperature radiation hardening.
In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.
External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.
Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).
The total radiation rate, angular distribution of the emitted energy and photon correlations of the cooperative spontaneous radiation from two atoms with different resonance frequencies and spontaneous decay rates are calculated. Contrary to the case of two identical atoms oscillations appear in the total radiation rate and the spatial distribution of the total number of emitted photons differs from the single-atom radiation pattern. The effect of the dipole-dipole near-field interaction on the time evolution of the atomic system is discussed. (author).
Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).