Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge
International Nuclear Information System (INIS)
Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of ...
Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses
Energy Technology Data Exchange (ETDEWEB)
Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.
2007-11-15
Radiation-annealing hardening of vanadium
International Nuclear Information System (INIS)
A study is made of the mechanical properties of vanadium irradiated with fast neutrons up to dose 8.6.10"-"4 dpa, as a function of the temperature of post-radiation annealing. The radiation-annealing hardening (RAH) effect is observed at 300"oC, in agreement with previous studies. It is established for the first time that RAH is accompanied by fall in ductility. A phenomenological model is described which explains the dependence of RAH on radiation dose and temperature, as well as on the content of chemically active alloying impurities. (author).
Ionizing radiation effect on sealant properties
International Nuclear Information System (INIS)
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not ...
Procedure for radiation dose control in irradiated tissues during electron-beam therapy
International Nuclear Information System (INIS)
The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron ...
1984-11-08
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
1988-02-23
The influence of scattered radiation on recording systems and quality-assurance test parameters
International Nuclear Information System (INIS)
Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).
British Library Electronic Table of Contents (United Kingdom)
There is proposed the nonlinear model of dose dependence saturation of the yield strength on the base of the vacancy and interstitial barrier interaction in this work. Processes of mutual recombination of vacancy and interstitial barriers and formation of vacancy and interstitial clusters are taken into consideration. In the framework of the model, the analytical equations corresponding to the evolution of the barrier densities and yield strength are obtained. It is shown that the yield strength of irradiated materials decreases with the increasing intensity of barrier recombination processes, the dependence being nonlinear. Also it is shown that the model is valid both for low doses and large doses on the stage of radiation hardening.
2009-01-01
Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).
1991-01-01
Radiation hardening characterization of a VDMOS developed at CAS institute of microelectronics
International Nuclear Information System (INIS)
Total dose irradiation effects on a VDMOS developed at Institute of Microelectronics, CAS were investigated, particularly the electric parameter changes under different bias conditions. It was found that the breakdown voltage degradation by the irradiation depended mainly on the drain bias, whereas the threshold voltage degradation depended mainly on the gate bias. Thus, an innovative and effective method to domestic VDMOS total dose ionization characterization is that threshold voltage radiation hardening characterization should be tested on gate bias condition, and the breakdown voltage radiation hardening characterization, be tested on the drain bias. (authors)
2008-08-01
Somatic and genetic effects of small doses of ionizing radiations in man
International Nuclear Information System (INIS)
Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high ...
1976-01-01
International Nuclear Information System (INIS)
We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to ...
2011-02-01
Radiation-annealing hardening of vanadium
International Nuclear Information System (INIS)
Mechanical properties of vanadium, irradiated with fast neutrons up to 8.6x10"-"4 dpa depending on postirradiation annealing temperature, are studied. It is shown that radiation-annealing hardening (RAH) is observed at 300 deg C, which agrees with earlier performed studies. It is first stated that RAH is accompanied by plasticity decrease. Phenomenological model permitting to explain RAH dependence on irradiation temperature and dose and also on content of chemically active alloying impurities is suggested.
International Nuclear Information System (INIS)
... organizations irradiation radiation doses radiation effects RADIATIONS.
1982-01-01
Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)
International Nuclear Information System (INIS)
The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. ...
1986-01-01
International Nuclear Information System (INIS)
The results of an investigation into tailed nuclei (TN) and features of dose dependence on frequency of the binuclear cells with TN in human lymphocyte cultures by cytogenetic block method upon X-ray radiation dose are presented. The frequencies of metaphases with dicentric and ring chromosomes are investigated concurrent with TN formed upon completion of first postradiation mitosis. Frequency of the appearance of binuclear cells with nuclei having outgrowth into the cytoplasmic space and arises after first mitosis in human lymphocyte culture is linear-square dependent on the X-irradiation at doses from 0.0 to 4.0 Gy. Positive correlation between frequency of cells with tailed nuclei and frequency of metaphases of first mitosis having dicentric and rings was established. Apparently, formation such TN is connected with dicentric and rings
Dose dependence of semiconductor material conductivity as a means of high fluence dosimetry
Energy Technology Data Exchange (ETDEWEB)
Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).
1996-12-31
Somatic radiation risk in different mammography techniques
International Nuclear Information System (INIS)
By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography ...
1981-01-01
Development of internal dose estimation software on radiation protection
International Nuclear Information System (INIS)
Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)
2008-10-01
The dependence of radiation hardening and embrittlement on irradiation temperature
International Nuclear Information System (INIS)
Assessments of the hardening and embrittlement of pressure vessel steels and welds as a function of neutron dose use trend curves derived from surveillance programs and accelerated irradiation data. A temperature dependent factor is incorporated for assessing vessel locations operating at different temperatures. As hardening and embrittlement arise from the sum of matrix damage and copper impurity precipitation, the influence of irradiation temperature on each process needs to be established. For irradiations performed below #approx# 300 C recent data shows that the dose-dependent growth of copper precipitates ceases at a mean diameter of about 2 nm that also corresponds to peak hardening and embrittlement by copper. For doses beyond this peak copper dose the property-dependence on irradiation temperature can be identified with that of matrix damage alone. An ...
1994-06-20
International Nuclear Information System (INIS)
From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).
1984-01-01
IRSL characteristics of NaCl and KCl relative to dosimeter
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is to determine and compare the dosimetric properties of NaCl and KCl samples using infrared-stimulated luminescence (IRSL) technique. For a material to be used as dosimeter, both the IRSL temperature dependence and the radiation dose response have critical importance. In this work the IRSL characteristics from NaCl and KCl samples were experimentally investigated as a function of temperature and laboratory radiation doses. Dosimetric properties of NaCl and KCl samples were found significantly different. The IRSL signals displayed by NaCl were found to be more stable, reliable and agreeable than those of KCl.
2007-01-15
Induction of sterility in adults of Earias vittella Fabricius through late pupal irradiation
International Nuclear Information System (INIS)
Studies on pupal irradiation of Earias vittella Fabricius, were undertaken to determine the optimum dose for sterile and competitive adults. Late pupae were irradiated with gamma radiation doses ranging from 150 to 300 Gy. Emerging adults were normal and without malformation. When males that emerged from irradiated pupae were crossed with normal female, fecundity as well as longevity was comparable to control, but there was drastic reduction in percent egg hatch in all the treatments. However, when females emerging from irradiated pupae were crossed with normal male, there was reduction in the fecundity as well as fertility and this effect was dose dependent. (author).
International Nuclear Information System (INIS)
... radiation effects human populations low dose irradiation neoplasms radiation
1980-01-01
International Nuclear Information System (INIS)
... pathological changes patients radiation protection radiotherapy diseases
1982-10-25
Study of somatic radiation effects in environment
International Nuclear Information System (INIS)
A survey is presented of the consequences of the irradiation of the population with ionizing radiation. There is an increased incidence of leukemia in irradiated population groups. Among the inhabitants of Hiroshima and Nagasaki maximum death of leukemia was observed in the years 1951 to 1952. The results are summed up of the observation of carcinoma of the breast, lungs and bronchi, bones, and carcinoma of the thyroid. The effect of radiation on experimental animals is described. It was found that the scatter of the dependence of the incidence of various types of cancer on the dose equivalent apparently reflects differences in the biological mechanism of this incidence and that a proportional relationship cannot be expected between the primary damage of cells during irradiation and the actual manifestation of the disease. (E.S.).
Retrospective individual dosimetry using luminescence and EPR after radiation accidents
International Nuclear Information System (INIS)
In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is ...
International Nuclear Information System (INIS)
An attempt was made for early quantitative assessment of the severety of an injury, using the nuclear acids (NA) content as a biochemical indicator. Sexually mature male rats with body mass 160-180 g were irradiated with doses 0.5, 1, 2, 4 and 8 Gy of "1"3"7Cs source. Uneven irradiation was achieved by shielding the abdominal-lumbar area with lead rings, measuring 2,5/50 mm. A 28-30% fall of the dose beneath the shielded zone was thus provided. Dose-dependent quantitative changes in Na content were determined on hours 24 and 72 within the range from 0.5 to 8 Gy and followed up until day 30 after irradiation with nonlethal (2 Gy) and lethal (8 Gy) doses. The total NA content in the leucocytes was determined by the method of Kritski and Aleksandrov. The uneven irradiation of rats within the 0,5-8 Gy range induced early dose-dependent changes in NA content. The nature of their ...
Alpha-particle dose distribution effects at the cellular level
International Nuclear Information System (INIS)
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
1985-02-01
Viscosity changes in hyaluronic acid: Irradiation and rheological studies
Energy Technology Data Exchange (ETDEWEB)
Hyaluronic acid (HA) is a significant component of the extracellular matrix (ECM), particular interest being shown herein in synovial fluid. The present study aims to investigate the degrading effects of X-ray radiation on HA at radiotherapy doses. Measurements of viscosity and shear stresses on HA solutions have been made at different shear rates using various types of viscometer for different concentrations in the range 0.01-1% w/v of HA. The HA has been subjected to doses of 6 MV photon radiation ranging from 0 to 20 Gy, the major emphasis being on doses below 5 Gy. It is found that there is a dose-dependent relationship between viscosity and shear rate, viscosity reducing with radiation dose, this being related to polymer scissions via the action of radiation-induced free radicals. The ...
2010-04-15
Animal Models for Radiation Injury, Protection and Therapy
... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
International Nuclear Information System (INIS)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence ...
2007-09-15
The effect of irradiation on packaging materials
International Nuclear Information System (INIS)
Ionizing radiation, mainly in the form of #gamma#-rays from the radioisotope cobalt 60, is being used increasingly for the inactivation of contaminants in cosmetic and toiletry preparations. The treatment is applied to the product in its final pack, and therefore, it is important to recognize that the properties of the packaging materials could be affected, particularly if high radiation doses are used. The stability of a wide range of materials is discussed. The nature and extent of chemical and physical changes in plastics very much depends on the presence of antioxidants and other additives, and on the environmental conditions during irradiation. Some useful information is available from research into the use of radiation for the preservation of food - many films and laminates have been cleared for use in the United States. The low radiation ...
Radiation dose in computerized tomography
International Nuclear Information System (INIS)
Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.
Complex radiation degradation behaviour of PVC materials under accelerated aging conditions
International Nuclear Information System (INIS)
The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the levelling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests. (author).
1982-10-01
Complex radiation degradation behavior of PVC materials under accelerated aging conditions
Energy Technology Data Exchange (ETDEWEB)
The radiation degradation behavior of three commercial polyvinyl chloride (PVC) materials has been investigated. All three exhibit an interesting reversal in the trend of the tensile strength part way through the aging experiment: the tensile strength first drops, then rises. The early drop is associated with oxidative scission; the rise is associated with crosslinking and is preceded by the material reaching the gel point. It was also found that the tensile elongation tended to level out in advanced stages of aging with the leveling-out values dependent on the dose rate. These phenomena pose complications for the design of accelerated aging tests.
1983-07-01
Effect of decrease of molybdenum radiation hardening at high energy proton irradiation
International Nuclear Information System (INIS)
By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.
1990-05-22
Energy Technology Data Exchange (ETDEWEB)
In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation ...
2007-07-01
Effective dose equivalent in nuclear medicine investigations
International Nuclear Information System (INIS)
... radiation hazards hazards health hazards MEDICINE. SOMATICALLY
1984-05-07
Bulgarian population exposure resulting from diagnostic nuclear-medicine applications
International Nuclear Information System (INIS)
... populations radiation doses RADIOACTIVE MATERIALS. SOMATICALLY
1980-10-26
On-site radiation exposure in severe reactor accidents: Scoping study
Energy Technology Data Exchange (ETDEWEB)
The results of a scoping study of onsite radiation exposures which could take place in each of three types of postulated reactor accidents are presented. The accident types are (1) a fuel handling accident at a Mark III BWR; an interfacing system LOCA or V sequence at a PWR; and and Anticipated Transient Without Scram (ATWS) at a Mark I BWR. Both external and internal dose pathways are considered. The results of the study indicate the prohibitively high radiation doses could be received in some plant areas if personnel were to remain there. However, times of the order of a few minutes to a few hours, depending on the type of accident, would be available before life-threatening doses would be accumulated assuming that the provided full face respiratory protection equipment were used promptly. Special attention was given radiation ...
1990-09-01
X-ray dose enhancement effects
International Nuclear Information System (INIS)
A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.
Effects of small doses of ionizing radiation on human health
Energy Technology Data Exchange (ETDEWEB)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-12-01
Effects of small doses of ionizing radiation on human health
International Nuclear Information System (INIS)
The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).
1997-01-01
Further means for reducing radiation dose during exposure of the pelvis in infants
International Nuclear Information System (INIS)
A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).
Assessment of dose-time-effect surfaces for somatic late effects after low dose irradiation
International Nuclear Information System (INIS)
Awaiting new data from RERF, an attempt was made to estimate the somatic risks of low doses of radiation for members of the German public. The new estimate follows closely the approach used in deriving the values published in the NIH Radioepidemiological Tables. The lifetime risk factors thus calculated are significantly larger than the estimates presented in ICRP Report 26 and are consistent with estimates recently made in the ongoing reactor safety study of NUREG. The increase in lifetime risks is mainly due to the introduction of a new time projection model which appears to be more consistent with the epidemiological data for many late effect end points than the constant absolute risk model previously employed. Results from a study in which epidemiological data were stochastically simulated with a computer indicate that the shapes of actual dose effect curves might be significantly more influenced by pure chance than by ...
1988-04-01
Radiation exposure of the population of the GDR by X-ray diagnostics
International Nuclear Information System (INIS)
The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.
1986-01-01
Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries
UK PubMed Central (United Kingdom)
Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available
2005-07-09
Energy Technology Data Exchange (ETDEWEB)
This report concerns investigations in the title conducted by 8 groups of National Institute of Radiological Sciences (NIRS) during the period of 1998-2000. The groups are for investigation of: Effects of p53 tumor suppressor gene in radiation-induced leukemia, Role of atm-gene in dose rate effect of ionizing radiation, Function of DNA-dependent protein kinase catalytic subunit (DNA-PK{sub cs}), Functional complementation of radiation-sensitive mutant M10 cell line by human XRCC4 cDNA expression, Role of radiation-induced apoptosis in digital defects in embryonic mice, Functional analysis of S-phase specific novel nuclear protein NP95 by gene targeting, Role of chemokine in T cell development and lymphomagenesis, and establishment of production techniques of gene-modified mice using embryonic stem cells for genetic analysis of ...
2002-03-01
International Nuclear Information System (INIS)
In its 1990 recommendations, the ICRP considered the radiation risks after exposure during prenatal development. This report is a critical review of new experimental animal data on biological effects and evaluations of human studies after prenatal radiation published since the 1990 recommendations. Thus, the report discusses the effects after radiation exposure during pre-implantation, organogenesis, and fetogenesis. The aetiology of long-term effects on brain development is discussed, as well as evidence from studies in man on the effects of in-utero radiation exposure on neurological and mental processes. Animal studies of carcinogenic risk from in-utero radiation and the epidemiology of childhood cancer are discussed, and the carcinogenic risk to man from in-utero radiation is assessed. Open questions and needs for future research are elaborated. The report ...
Method of describing dose distributions in computer design of teleradiotherapy
International Nuclear Information System (INIS)
Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.
Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...
1980-01-01
Radiation protection in the operating room
International Nuclear Information System (INIS)
On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.
Radiation risk in diagnostic radiology
International Nuclear Information System (INIS)
An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).
1984-01-01
International Nuclear Information System (INIS)
A study was made into microstructure and hardening in austenitic stainless steel 0Kh18N10T irradiated with neon ions (230 MeV) and neutrons (E_n > 0.1 MeV). The experiments were accomplished using an external beam of U-400 cyclotron (Dubna) and EWA reactor (Poland). The dependences of tensile properties, hardening index, microstructure, dislocation density on damaging dose were determined. An attempt is made to reveal the correlation between an yield strength increment and defect cluster accumulation. The interpretation of variations of mechanical properties and microstructure under irradiation is given.
Radiotherapeutic methods for Ewing's sarcoma of the long tubular bones in children
International Nuclear Information System (INIS)
Radiotherapeutic results of the Ewing sarcoma of the long tubular bones in 140 pediatric patients aged 3-16 are analyzed with the respect to different methods of irradiation. Three-field irradiation, the fields being located at 120 deg to one another with daily irradiation of all three fields at a focal dose of 2 Gy, was found superior in treatment of primary neoplasm. It is stressed that the disease termination mainly depends on the efficiency of primary neoplasm treatment, as the neoplasm reccurence generally is followed by metastases. Radiation load is calculated for maximal irradiation area of soft tissues in children.
The radon therapy - radon inhalatorium in Kowary
International Nuclear Information System (INIS)
In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)
Somatic radiation risk in X-ray diagnostics
Energy Technology Data Exchange (ETDEWEB)
The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.
1983-12-01
Somatic radiation risk in X-ray diagnostics
International Nuclear Information System (INIS)
The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).
1983-01-01
New concepts in risk assessment for patients with radiological treatment
International Nuclear Information System (INIS)
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
1986-01-01
Stereotactic body radiotherapy for unresectable cholangiocarcinoma
International Nuclear Information System (INIS)
Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum ...
2010-01-01
Characterization of an add-on multileaf collimator for electron beam therapy
Energy Technology Data Exchange (ETDEWEB)
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric ...
2008-02-21
Energy Technology Data Exchange (ETDEWEB)
Population residing in the northern part of the Chelyabinsk oblast and the south eastern part of the Sverdlovsk oblast of Russia affected to accidental exposure since 1957. The territory (East Ural Radioactive Trace - EURT) was contaminated after explosion of container with highly radioactive wastes at the Mayak Production Association. Studies of health effects of exposure in the southern, head part of EURT are conducted in the Ural Research and Practical Center of Radiation Medicine (U.R.P.R.M.). In the 1990's U.R.P.C.R.M. formed a cohort of EURT within Chelyabinsk oblast (14,500 cases and 19,400 external controls). The cohort was followed in 1957-1987 and the results of the study are discussed by Crestinina et al. First results of study on exposure late health effects among rural population in the northern part of the EURT are presented in this paper. Firstly, or the period 1958-2000 a statistically significant increase in cancer mortality associated ...
2006-07-01
Irradiation of polyethylene in the presence of antioxidants
International Nuclear Information System (INIS)
The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbed doses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).
The malignancy significant dose from external beam radiotherapy
International Nuclear Information System (INIS)
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
Langmuir-Blodgett (LB) preparations containing stacked monolayers of phospholipids or stearic acid were irradiated with UV light and the electric conductance perpendicular to the planes of the monolayers was measured. There was no observable change of conductance when LB preparations of stearic acid were irradiated. For LB preparations of phospholipids, a rise of conductance, dependent on dose rate, was observed, reaching an equilibrium level after a few hours. After irradiation the conductance fell with a temperature-dependent time constant, and eventually reached a final level a little above the initial value. A three-state model is proposed for the LB phospholipid preparations. This suggests that the absorption of one photon raises a molecule from the ground to an excited state; and the absorption of a second photon carries it into a damaged but repairable or metastable state. (author).
1992-12-01
The importance of radiation quality for optimisation in radiology
UK PubMed Central (United Kingdom)
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
International Nuclear Information System (INIS)
Purpose/Objective: The role of programmed cell death (apoptosis) as a cellular response to cancer therapy such as radiation or chemotherapy is the subject of much study, and manipulation of the apoptotic response in tumor cells may be valuable in the treatment of a variety of cancers. Both p53 dependent and independent apoptotic pathways have been identified; p53 is mutated in at least 50 % of human cancers and a majority of radiation resistant tumors contain p53 mutations. This study is designed to examine the induction of programmed cell death in a human colon carcinoma cell line that possesses two mutated p53 alleles. Ionizing radiation alone, or in combination with the chemotherapeutic drug 5-fluorouracil (5-FU), were used to elicit the apoptotic response. This study will focus on whether these treatments can induce a significant apoptotic response in cells that have mutated p53 alleles. Materials ...
1996-09-01
UK PubMed Central (United Kingdom)
For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available
2008-11-01
Radiation risks for medical applications
International Nuclear Information System (INIS)
The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).
1980-05-31
UK PubMed Central (United Kingdom)
BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available
Induction of tumors by screening mammography
International Nuclear Information System (INIS)
Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.
1983-01-01
Epidemiological survey of the effects of low level radiation dose: a comparative assessment
Energy Technology Data Exchange (ETDEWEB)
This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).
1993-10-01
UK PubMed Central (United Kingdom)
Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available
2009-03-21
UK PubMed Central (United Kingdom)
Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available
International Nuclear Information System (INIS)
Brachytherapy refers to short distance treatment of cancer with radiation from small, encapsulated radionuclide sources. This type of treatment is given by placing sources directly into or near the volume to be treated. The dose is then delivered continuously, either over a short period of time (temporary implants) or over the lifetime of the source to a complete decay (permanent implants). This technique is extensively used in the treatments of gynecological, breast, prostate, head and neck, and other soft tissue cancers. The clinical outcomes of this treatment depend on accurate dosimetry and dose delivery. The patient is generally considered to be water equivalent. So the treatment planning system software generally is based on measured or calculated dose distributions in homogenous water medium. In real situation, the treatment volume is not homogenous water medium, but it is a ...
2009-04-01
Water Concentration Dependent Photochemistry of Ketoprofen in Neutral Aqueous Solutions
International Nuclear Information System (INIS)
... v. 1267(1) RADIATION CHEMISTRY, RADIOCHEMISTRY AND NUCLEAR
2010-08-06
Survey of radiation doses to patients from the diagnostic use of X-rays
International Nuclear Information System (INIS)
The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).
1977-06-01
X-ray dosimetry of TlGaSe_2 single crystals
International Nuclear Information System (INIS)
TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# ...
Radiological characterization of the GRR-1 pool
International Nuclear Information System (INIS)
GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the present work is the ...
2007-11-05
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy ...
1993-10-13
Influence of the circadian rhythm in cell division on radiation-induced mitotic delay in vivo
Energy Technology Data Exchange (ETDEWEB)
Mitotic delay is described as a classical response to radiation; however, circadian rhythmicity in cell division in vivo has not been considered by many authors. The present study investigated the relation between fluctuations reported as mitotic delay and recovery in vivo and circadian oscillations in mitotic index in mouse corneal epithelium. One aspect involved single doses (approximately 600 rad) given to mice at different circadian stages. The normal circadian rhythm in cell division was never obliterated. Inhibition of mitosis was evident but unpredictable, ranging from 6 to 15 hr after irradiation. Recovery was evident only during the daily increase in mitotic index of controls. The classical interpretation of recovery from mitotic delay may be in an in vitro phenomenon not reflecting in vivo responses, which are apparently strongly circadian stage dependent. The second portion of the study demonstrated a ...
1982-01-01
Standard radiation monitoring at Sendai nuclear power station
International Nuclear Information System (INIS)
Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).
Energy Technology Data Exchange (ETDEWEB)
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...
2000-03-01
International Nuclear Information System (INIS)
The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation ...
2006-09-01
A study of neutron room scattering at RPCF
International Nuclear Information System (INIS)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...
1997-01-05
A study of neutron room scattering at RPCF
Energy Technology Data Exchange (ETDEWEB)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National ...
1996-09-01
Four cases of bowel perforation following radiation therapy for cervical cancer
Energy Technology Data Exchange (ETDEWEB)
External radiation dose exceeded 5,000 rad in three cases, and intravaginal radiation dose was 5,000 rad in one case. Radiation damage including perforation was seen in the end of ileus in one case, in the sigmoid and rectum in two cases, and in the end of ileus, sigmoid and rectum in the last case. Satisfactory results were obtained by the removal of the ileocecum in the case of the damage in the end of the ileus. However, only colostomy was performed for the damage in the sigmoid and rectum.
1984-10-01
Worker radiation doses in the United States at the dawn of the atomic era (1940--1960)
Energy Technology Data Exchange (ETDEWEB)
Radiation doses to workers at the Manhattan Engineer District (MED) and US Atomic Energy Commission (AEC) sites due to external irradiation during 1940--1960 are reviewed. Categorized radiation dose data were available from AEC annual reports for some years. Annual individual radiation dose data for ten MED/AEC sites for all years were available from the US Department of Energy`s (DOE) Comprehensive Epidemiologic Data Resource (CEDR). These data are combined to produce an estimate of external collective dose equivalent to 172,000 person-rems (1720 person-Sv) for 1940--1960. During this period there were 41 overexposures, 19 criticality incidents, and 3 deaths due to acute radiation syndrome among several hundred thousand workers.
1994-06-01
International Nuclear Information System (INIS)
The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for ...
1984-01-01
Radiation exposure to patients during hepatic interventional procedure
International Nuclear Information System (INIS)
Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)
2005-05-01
International Nuclear Information System (INIS)
Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing ...
2006-04-01
International Nuclear Information System (INIS)
The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant ...
1984-06-01
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for ...
Projection techniques in diagnostic radiography discussed with regard to required dose
International Nuclear Information System (INIS)
The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).
1990-09-01
Development of barcode system for internal dose monitoring
International Nuclear Information System (INIS)
In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal ...
2008-11-19
Radial dose distribution of 6.0 MeV/n #alpha#-particle in water
International Nuclear Information System (INIS)
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux is injected in the human body like radiotherapy using ...
2003-08-17
Acceleration of the development of benzopyrene-induced skin cancer in mice by microwave radiation
Energy Technology Data Exchange (ETDEWEB)
In the present study Balb/c mice were exposed to 3,4-benzopyrene, painted on the skin every 2nd day for a total of 6 months, and simultaneously irradiated with athermal (5 mW/cm/sup 2/) or subthermal (15 mW/cm/sup 2/) doses of 2,450 MHz microwaves. The other group of animals was preirradiated with microwaves at 10 mW/cm/sup 2/ power level for 1, 2, or 3 months and then treated with benzopyrene, as above. Control mice were exposed for 6 months to benzopyrene, resulting in the development of baso- or spinocellular skin carcinoma within approximately 9 months, and sham-irradiated with microwaves. The growth of the tumour was assessed according to a self-designed 7-range macroscopic scale, supported by microscopical examinations of skin sections. All protocols of microwave irradiations resulted in a significant acceleration of the development of benzopyrene-induced skin cancer and in shortening of life span of the tumour-bearing hosts. This effect seemed to be ...
1982-12-01
Induction and use of sex linked lethal mutations in the pink bollworm
International Nuclear Information System (INIS)
The sterile insect release technique can often be improved by removal of females before release. Rearing efficiencies can also be increased if removal of the females occurs at early developmental stages. In order to begin to develop genetic sexing strains for the pink bollworm, Pectinophora gossypiella (Saunders), it was necessary to determine the best dosage of radiation for induction of viable sex linked recessive lethal mutations and to see if stocks containing induced sex linked lethals could be maintained in culture. Sex linked recessive lethal mutations can be detected by distorted sex ratios in the progeny of treated adults. However, in the pink bollworm, highly distorted sex ratios are common even in the absence of induced mutations. Therefore, a visible sex linked trait, purple eye, was used as a marker for the untreated X-chromosomes in crosses. Thus, the presence of a recessive sex linked lethal mutation induced by the radiation ...
1987-11-16
Seasonal variation measurements of radon levels in caves using SSNTD method
Energy Technology Data Exchange (ETDEWEB)
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
2008-08-15
Seasonal variation measurements of radon levels in caves using SSNTD method
International Nuclear Information System (INIS)
The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.
2008-08-01
Experiments on determination of damage effect ions "2"2Ne (172 MeV) on UO_2 monocrystals
International Nuclear Information System (INIS)
Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
UK PubMed Central (United Kingdom)
IntroductionThe objective of this study was to examine age-, hormone-, and sex-dependent differences to the behavioral effects of nicotine using place-conditioning...Full Text Available
2009-10-01
Population exposure to external natural radiation background in the United States
Energy Technology Data Exchange (ETDEWEB)
This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.
1981-04-01
International Nuclear Information System (INIS)
Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum slanting ...
2004-08-23
Energy Technology Data Exchange (ETDEWEB)
The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)
2008-12-15
International Nuclear Information System (INIS)
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The balance of the ...
2003-06-01
International Nuclear Information System (INIS)
The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the ...
2007-05-01
Effects of antioxidants on lipid peroxide formation in irradiated synthetic diets
International Nuclear Information System (INIS)
The effects of the antioxidants, vitamin E, propyl gallate, 2-t-butyl-4-methoxy phenol (BHA), 2,6-di-t-butyl-4-methoxy phenol (BHT), nor-dihydroguaiaretic acid (NDGA) and diphenyl-p-phenylene diamine (DPPD) in concentrations ranging between 0.001 per cent and 0.1 per cent have been tested on lipid peroxide formation in synthetic diet mixtures containing herring oil (10 per cent) mixed with starch (90 per cent) irradiated with #gamma#-ray doses of 100 to 2000 krad. On a weight basis NDGA, DPPD, BHA and BHT were most effective and vitamin E and propyl gallate were least effective. An antioxidant concentration of 0.01 per cent normally protected against peroxide formation after a dose of 500 krad but if the dose was increased to 1000 or 2000 krad, much higher doses of antioxidant, up to 0.1 per cent, were required to give protection. Antioxidants prevented peroxide developing during post-irradiation ...
Concepts of radiotherapy treatment planning
International Nuclear Information System (INIS)
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...
2000-12-01
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the ...
1992-07-12
Potential Hazards from Neutrino Radiation at Muon Colliders
High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.
1999-01-01
Radiation doses in adults and children in standardized diagnostic radiology
International Nuclear Information System (INIS)
For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.
1987-01-01
Radiation doses and somatic risk to patients during cardiac radiological procedures
International Nuclear Information System (INIS)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
1986-01-01
International Nuclear Information System (INIS)
The decree refers to conditions of irradiation of food and its components for radappertization and radurization using gamma radiation from cobalt 60 or cesium 137, X radiation or electron beam up to maximum total medium absorbed dose 10 kGy.
2003-03-04
Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications
International Nuclear Information System (INIS)
A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.
1996-07-15
Energy Technology Data Exchange (ETDEWEB)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.
1980-10-01
International Nuclear Information System (INIS)
The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).
1980-01-01
Electrical conductivity of the ceramic AIN under irradiation
Energy Technology Data Exchange (ETDEWEB)
Aluminum nitride has been proposed as electrically insulating coating in connection with blankets made of vanadium alloys. Irradiations were performed with an applied DC electric field of 100 kV/m, using a 104 MeV {alpha}-particle beam. The dose achieved were 0.1 dpa at 300 C, 0.05 dpa at 400 C, and 0.06 dpa at 500 C. The out-of-beam conductivity {sigma}{sub 0} decreased at all temperatures employed during early stage of irradiation. Before 0.02 dpa had been reached, {sigma}{sub 0} dropped to low values of typically (2-4) x 10{sup -11} ({Omega} m){sup -1}. Although a moderate increase can be observed during further irradiation, {sigma}{sub 0} remained below the initial value of the unirradiated specimen for all temperatures. That is, there is no significant evidence for radiation induced electrical degradation. The in-beam conductivity {sigma}, measured continuously during irradiation, also decreased by at least one order of magnitude. Relevant ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
The linear/supralinear behaviour of the TL dose response in LiF:Mg,Ti (TLD-100) and its dependence on ionisation density is a fairly unique phenomenon which cannot be explained by conventional atomic 'conduction band/valence band' kinetic models. The Track Interaction Model (TIM) provides the microscopic framework which, when coupled with other appropriate physical mechanisms (spatial localisation of traps and recombination centres, competing centres, variations in the capture cross sections with temperature, etc.) can be used to describe all the dominant features of the TL supralinearity of LiF:Mg,Ti and similar TL systems. The unique feature of the TIM applied to alpha particles is that it is an integral approach with only one free parameter, the average charge carrier migration distance in the luminescence recombination stage. Although the TIM provides a comprehensive description of the mechanisms underlying supralinearity ...
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from ...
1990-10-01
Long-term effects of inhaled uranyl nitrate in rats
International Nuclear Information System (INIS)
Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.
1977-05-01
"2"0"3Pb yields while irradiating thallium with protons and deuterons
International Nuclear Information System (INIS)
... data deuteron beams energy dependence errors gamma radiation lead 203
Energy Technology Data Exchange (ETDEWEB)
Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).
1990-07-01
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22
A marine compartment model for collective dose assessment of liquid radioactive effluents
International Nuclear Information System (INIS)
A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).
1982-01-01
Dose planning and dose delivery in radiation therapy
International Nuclear Information System (INIS)
A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of ...
2008-08-01
Radiation doses from flying through nuclear-debris clouds. Final report, 2-10 January 1985
Energy Technology Data Exchange (ETDEWEB)
Taboada et al. have recently developed a computer model to predict gamma radiation doses to aircrews flying through nuclear-debris clouds. Although the model has the advantages of taking a large number of parameters into account and using the benchmark DELFIC code to model cloud dynamics, it takes up to 20 min for a single run on a mainframe computer. Results from a number of runs have been generalized into empirical formulae. From these results it is possible to estimate worst case gamma radiation doses for complex scenarios using a hand calculator.
1986-04-01
Influencing factors on ESR dose assessment in irradiated chicken legs
Energy Technology Data Exchange (ETDEWEB)
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
1996-12-31
Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV
Energy Technology Data Exchange (ETDEWEB)
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
1989-01-01
Effect of radiation dose on the properties of natural rubber nanocomposite
Energy Technology Data Exchange (ETDEWEB)
Effect of radiation dose and carbon nanotubes (CNT) on the mechanical properties of standard Malaysian rubber (SMR) was investigated in this study. SMR nanocomposites containing 1-7 phr CNT were prepared using the solvent casting method and the nanocomposites were radiated at doses of 50-200 kGy. The change in mechanical properties, especially, tensile strength (Ts), elongation at break (Eb), hardness and tensile modulus at 100% elongation (M{sub 100}) were studied as a function of radiation dose. The structure and morphology of reinforced natural rubber was investigated by FESEM, TEM and AFM in order to gain further evidence on the radiation-induced crosslinking. It was found that the Ts, M{sub 100} and the hardness of the SMR/CNT nanocomposites significantly increased with radiation dose; the ...
2010-12-15
Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions
Energy Technology Data Exchange (ETDEWEB)
Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).
1992-02-01
International Nuclear Information System (INIS)
After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...
1999-07-01
Radiation reduction of dicarboxylatoimidazole platinum(II) complexes in the water-methanol system
Energy Technology Data Exchange (ETDEWEB)
The radiation reduction of bis(1-ethylimidazole)tartratoplatinum(II) (EITPt(II)) complexes in methanol-water solution have been examined. The yields of Pt(I) depend on the presence of O{sub 2} in solutions as well as the dose applied. The rate constants of e{sub s}{sup -} scavenging by EITPt(II) and cis(diammine-1,1-cyclobutanedicarboxylato) platinum(II) (CBDCAPt(II)) have been determined by pulse radiolysis to be equal to 5.4 x 10{sup 9} and 6.4 x 10{sup 9} M{sup -1} s{sup -1}, respectively. The efficiencies of e{sub t}{sup -} scavenging by EITPt(II) and the rate of e{sub t}{sup -} photobleaching have also been determined in LiCl : H{sub 2}O : CH{sub 3}OH and MgCl{sub 2} : H{sub 2}O : CH{sub 3}OH glasses, respectively. (author).
1997-10-01
International Nuclear Information System (INIS)
Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).
Radiation oxidation of phenol in petrochemical waste water. II
International Nuclear Information System (INIS)
The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and ...
1981-01-01
Paediatric radiography - the avoidance of late radiation damage to the growing hip
Energy Technology Data Exchange (ETDEWEB)
Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).
1993-04-01
International Nuclear Information System (INIS)
... OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS
2006-10-09
Efficiency of a lead-containing tie for radiation protection of the thyroid gland
Energy Technology Data Exchange (ETDEWEB)
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. ...
1992-11-01
Efficiency of a lead-containing tie for radiation protection of the thyroid gland
International Nuclear Information System (INIS)
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
International Nuclear Information System (INIS)
... 3-89701-147-6 0949-2224 245 p. animal cells dna genetic radiation effects
1998-03-01
Adaptive Management of Liver Cancer Radiotherapy
UK PubMed Central (United Kingdom)
Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available
2010-04-01
Spectral energy effects in ESR bone dosimetry: photons and electrons
International Nuclear Information System (INIS)
The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation ...
International Nuclear Information System (INIS)
CBA/Ca mice were infected by either the intravenous or intraperitoneal route with Mycobacterium microti and the subsequent changes in local macrophage populations examined. Following infection, the number of macrophages increased and they showed greater expression of both MHC Class II molecules. This response was not dependent on viability of the mycobacteria, in contrast to reports with other microorganisms such as Listeria. Studies in sublethally irradiated mice indicated that persistent antigen could give rise to a response after a period of host recovery which was radiation dose dependent. This procedure also highlighted differences in the regulation of different murine class II antigens in vivo, as seen by delayed re-expression of I-E antigens. Macrophage accessory cell function, as assessed by an in vitro T cell proliferation assay, correlated with Ia expression after fixation, but not after ...
Range and modulation dependencies for proton beam dose per monitor unit calculations
UK PubMed Central (United Kingdom)
Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available
2009-02-01
UK PubMed Central (United Kingdom)
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
2010-01-01
[Somatic radiation risk in conventional tomography of the skull and thorax].
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other x-ray examinations, especially computerised tomography. PMID:7134769
1982-10-01
Somatic radiation risk in conventional tomography of the skull and thorax
Energy Technology Data Exchange (ETDEWEB)
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography.
1982-10-01
Somatic radiation risk in conventional tomography of the skull and thorax
International Nuclear Information System (INIS)
The somatically significant dose index can be considered as a measure for the somatic radiation risk to which the population is exposed. Figures are stated for conventional tomography of the skull and thorax. These are compared with the corresponding data for other X-ray examinations, especially computerised tomography. (orig.).
1982-01-01
EPR dosimetry in chemically treated fingernails
UK PubMed Central (United Kingdom)
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
Food-grade PVC and PVDC/PVC films containing 28.3% dioctyladipate (DOA) and 5.0% acetyltributylcitrate (ATBC) plasticizers, respectively, were brought into contact with olive oil and were irradiated with {gamma}-radiation [{sup 60}Co] at doses equal to 4 kGy and 9 kGy corresponding to `cold pasteurization`. Irradiation was carried out at 8-10 C and samples were subsequently stored at 4-5 C. Contaminated oil samples were analysed for DOA and ATBC at intervals between 7 h and 97 h of contact, using an indirect GC method. Identical non-irradiated (control) samples were also analysed for DOA and ATBC content. Results showed no statistically significant differences in migrated amounts of DOA and ATBC between irradiated and non-irradiated samples. Neither were differences observed between samples irradiated at 4 kGy and 9 kGy. This was supported by identical IR spectra recorded for irradiated and non-irradiated samples and leads to the conclusion ...
1995-12-31
International Nuclear Information System (INIS)
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...
2008-05-01
Inherited sterility progeny gamma irradiated male Spiny Bollworm Earias Insulana Boisd
International Nuclear Information System (INIS)
The present work studies the fecundity, egg batching and mating of normal females of Earias Insulana Boisd. crossed with males irradiated as 24 h adult moths with two doses (80 and 100 Gy.) of gamma radiation. The male progeny were out bred or inbred with untreated individuals for two successive generations F_1and F_2 and their progeny was observed for any inherited deleterious effects on reproduction. The female fecundity and egg hatch were significantly reduced among P1,F1 and F2 generations by increasing the dosages applied to P_1 males as compared with the untreated control. The percentage of mating of P_1 females was significantly reduced at the two doses as compared to the untreated control. The average number of spermatophores per mated female was reduced among P_1,F_1 and F_2 generations when parental males were irradiated with 100 Gy. The larval and pupal mortality a,o mg F_1, F_2 and F_3 generations was high and ...
2003-01-01
Risk assessment for radiation protection purposes
International Nuclear Information System (INIS)
In defining criteria for good protection against ionizing radiation, it is important to assess quantitatively the likely risk of any radiation exposure. The 'somatic' risks to the individual result mainly from induction of cancer in the organs irradiated, and these risks can now be estimated on the basis of numerous detailed epidemiological surveys of exposed human populations. Estimates of the risk of hereditary effects, from genetic changes induced in germ cells, are based largely on the frequency with which such effects are induced in other species. In both cases the risk at very low dose can be inferred using knowledge of the way in which radiation damage is caused in tissues. Coherent systems of radiation protection are based on a restriction of doses to the whole body and to individual organs, such that the induction of cancer and genetic harm is ...
1980-01-01
Health risks arising from ionizing radiation and chemical pollutants
International Nuclear Information System (INIS)
In quantifying health risks arising from radiation exposure and synergistic effects promoted by radiation the dose-effect relationship must be used as a basis. Special problems arise in the extrapolation of experimental results or in the treatment of data in the region of low doses administered over long periods of time. For radiation protection purposes, especially manifestations of cancer and genetic effects are significant. The International Commission on Radiation Protection has published binding guiding values on the basis of which to assess the risk of cancer. The cancer risk and genetic risks are estimated for relevant dose ranges and compared with other factors of civilization. For the most important chemical pollutants emitted into the environment the possibilities of impacts arising from synergistic effects are discussed on the ...
1979-10-03
Estimation of X-rays dose in the crystals of final thickness
International Nuclear Information System (INIS)
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Application of low dose radiation for preservation of sea foods
International Nuclear Information System (INIS)
Treatment of food with low doses of gamma radiation has been recognized to have two main advantages. These consist of: (1) improvement of food safety by elimination of pathogens and (2) reduction of microbial spoilage and extension of shelf life of perishable items by reducing the number of viable spoilage organisms. Studies during the last few decades have conclusively proved the beneficial effects of radiation with respect to fishery products. The three potential areas of application to fish products include: (i) radurization for shelf life extension (ii) radicidation to eliminate food borne pathogens in the products and (iii) radiation treatment to dried products to control insects.
1994-03-01
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the ...
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL ...
1991-06-01
Experts' discussion on the possibility of quantification of the radiation hazard
International Nuclear Information System (INIS)
Due to the intensity and vast number of subjects, this Bremen experts' discussion, too, could discuss only part of the problem of the possibilitiy to quantify the radiation hazard. One preliminary result is that there is no scientific proof of the harmlessness of radiation exposure during normal operation of a nuclear power plant, either within the plant or in its vicinity. Other results are that some important questions can not be answered yet, and that there are important hints on the dangers even of low radiation doses. (GL).
1978-01-01
The medical exposures to ionizing radiations, it is a world priority in radiation protection
International Nuclear Information System (INIS)
The document published under A/63:46 and titled report of the scientific committee of United Nations for the study of ionizing radiations effects, gives the situation of the fifty sixth session of the committee that stood at Vienna from the 10. to 18. july 2008. In the chapter 3 of this report the writers summarize the strategic planning and the working program of the scientific committee for the period 2009-2013. They note that the committee worry about the inadequate means, particularly in personnel. The priorities for the given period will be the medical exposure of patients, the radiation levels and the effects of energy production, the exposure to natural radiation sources and the improvement of the understanding of the effects of the low doses radiation exposure. (N.C.)
Energy Technology Data Exchange (ETDEWEB)
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...
2006-07-01
Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection
Energy Technology Data Exchange (ETDEWEB)
To determine if barbiturates would protect brain at high doses of radiation, survival rates in rats that received whole-brain x-irradiation during pentobarbital- or lidocaine-induced anesthesia were compared with those of control animals that received no medication and of animals anesthetized with ketamine. The animals were shielded so that respiratory and digestive tissues would not be damaged by the radiation. Survival rates in rats that received whole-brain irradiation as a single 7500-rad dose under pentobarbital- or lidocaine-induced anesthesia was increased from between from 0% and 20% to between 45% and 69% over the 40 days of observation compared with the other two groups (p less than 0.007). Ketamine anesthesia provided no protection. There were no notable differential effects upon non-neural tissues, suggesting that pentobarbital afforded protection through modulation of ambient neural ...
1990-05-01
Whole-body counting in the Marshall Islands
Energy Technology Data Exchange (ETDEWEB)
In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the ...
1991-01-01
The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose
International Nuclear Information System (INIS)
The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with ...
1991-11-01
CT-Expo - a novel program for dose evaluation in CT
International Nuclear Information System (INIS)
CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses ...
1993-05-01
International Nuclear Information System (INIS)
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses ...
1993-01-01
Some aspects of molecular mechanisms common to radiation and chemical carcinogenesis are discussed, particularly the DNA damage done by these agents. Emphasis is placed on epidemiological considerations and on dose-response models used in risk assessment to extrapolate from experimental data obtained at high doses to the effects from long-term, low-level exposures. 3 references, 6 figures. (ACR)
1984-01-01
Induced mutation in Lupinus mutabilis sweet in Peru
International Nuclear Information System (INIS)
Mutagenesis of Lupinus mutabilis was started at the UNA LM (Peru) to obtain mutants with low alkaloid content and early germination. Varieties SCG 25 and Lib 020 were irradiated with gamma radiation. The optimum dose for the SCG 25 variety was 15 Krad and for Lib 020 15 to 20 Krad. The relation between the plant height and radiation dose fits the quadratic polynomial model.
1984-04-01
Radiation hardening of smart electronics
International Nuclear Information System (INIS)
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to ...
Basic mechanisms of radiation effects in the natural space radiation environment
Energy Technology Data Exchange (ETDEWEB)
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
1994-06-01
Development of radiological emergency preparedness technology
Energy Technology Data Exchange (ETDEWEB)
Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological microanalytic methods for assessing the health effect by ...
2000-04-01
Occupational exposure information system in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)
2005-07-01
Mechanism of radiation induced carcinogenesis: does a threshold exist?
International Nuclear Information System (INIS)
Epidemiological studies will not solve the shape of the dose effect curve for stochastic effects in the low dose range. Unicellular processes are necessary for the primary processes so that no threshold dose exists. This is evident for somatic and genetic mutations. Not clearly solved is this question for the complex carcinogenesis. These processes develop with manifold interacting molecular and cellular steps. (orig.).
1996-10-23
Energy Technology Data Exchange (ETDEWEB)
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
1981-09-01
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
International Nuclear Information System (INIS)
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier ...
1987-01-01
Analysis of dose rate build-up in Tarapur Atomic Power Station unit-4
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made ...
2005-11-23
Radiation decontamination of dry food ingredients and processing aids
International Nuclear Information System (INIS)
Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial ...
Radiation induced synthesis of low molecular weight of PTFE and their crosslinking in acetone medium
International Nuclear Information System (INIS)
Polytetrafluoroethylene was obtained by radiation induced polymerization of tetrafluoroethylene in acetone at 195 K. An average diameter of the products was very small compared with commercial one; it was about 0.3 micro-meters. The yield was reached to 100% with a dose of 4 kGy. The crystallinity of the products is decreasing with increasing dose. The products become amorphous, for higher irradiation doses. It was found that PTFE obtained by irradiation of TFE in acetone at 195 K has branching structure. This was demonstrated by means of "1"9F MAS NMR. (Author)
2007-09-03
Radiation exposure of patients and operators during interventional radiology
International Nuclear Information System (INIS)
Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).
1986-01-01
Accumulation and distribution of "8"5Kr in rats exposed to "8"5Kr atmospheres
International Nuclear Information System (INIS)
Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.
1977-05-01
The importance and unique aspects of radiation protection in medicine
British Library Electronic Table of Contents (United Kingdom)
Radiation protection in medicine has unique aspects and is an essential element of medical practice. Medical uses of radiation occur throughout the world, from large cities to rural clinics. It has been estimated that the number of medical procedures using radiation grew from about 1.7 billion in 1980 to almost 4 billion in 2007. In spite of these large numbers, there are many parts of the world without adequate equipment, where the ability to perform additional medical procedures would likely result in a net benefit. Medicine accounts for more than 99.9% of the per caput effective dose from man-made sources. The goal in medical exposure is not to give the lowest dose, but to provide the correct dose to enable the practitioner to make the diagnosis or cure a tumour. Too little or too much ...
2010-01-01
International Nuclear Information System (INIS)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic consequences. (UK).
1993-05-01
Energy Technology Data Exchange (ETDEWEB)
Recent research findings of epidemiologist Alice Stewart suggest that nuclear workers may be at risk of contracting cancer even though their measured occupational doses fall within current safety standards. It is argued that these standards are inappropriate as they are based on extrapolations of studies on survivors of the Hiroshima and Nagasaki explosions. These individuals received single doses of radiation, whereas today's nuclear industry personnel are exposed to low-level ionizing radiation over the length of their working lives. Stewart's team linked low dose occupational exposure to ionizing radiation with an increased risk of cancer in respiratory, digestive and blood-forming tissues. The nuclear industry and United States government agencies hotly contest these assertion with their potentially damaging political and economic ...
1993-05-15
Radiation hazard control report
Energy Technology Data Exchange (ETDEWEB)
The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.
1982-12-01
Pulse source of electron and X-ray radiations of subnanosecond duration
International Nuclear Information System (INIS)
The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed
An integrating dosimeter for pulsed radiation
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
1983-12-01
A radiation monitoring system for nuclear fusion devices
International Nuclear Information System (INIS)
Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)
2005-12-01
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) ...
2003-07-01
Radiological concepts in radiotherapy
International Nuclear Information System (INIS)
The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and ...
Surface modification of PTFE sheet by synchrotron radiation in the soft X-ray region
International Nuclear Information System (INIS)
Full text: The surface properties of poly (tetrafluoroethylene) (PTFE) are changed by the exposure to synchrotron radiation (SR). We succeeded in controlling the wettability of the PTFE surface from hydrophobic to hydrophilic by varying the substrate temperature during the SR irradiation and found that the wettability was ascribable to microstructure and chemical composition of surface.In these previous works, oxygen atoms were found to inhabit on the hydrophobic surface of PTFE. In this study, we investigated the surface modification of PTFE from the SR exposure experiment under the O_2 gas atmosphere. The SR exposure to the PTFE sheet was carried out at beamline 6 (BL6) of the New- SUBARU. The PTFE sheet was irradiated to the white beam, ranging 50-1000 eV at BL6 at room temperature. The gas cell was mounted at the irradiation chamber. The O_2 gas pressure in the gas cell can be maintained at about 0.20 Pa during the SR exposure using 5mm #phi# hole window. The ...
2004-07-19
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two ...
1996-12-31
Donut-shaped high-dose configuration for proton beam radiation therapy
Energy Technology Data Exchange (ETDEWEB)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
Donut-shaped high-dose configuration for proton beam radiation therapy
International Nuclear Information System (INIS)
Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...
2005-01-01
An evaluation of low-dose single-slice helical CT in pulmonary CT scan
International Nuclear Information System (INIS)
Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...
2006-04-01
Concepts in radiation protection
International Nuclear Information System (INIS)
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the ...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
Molybdenum is an essential element for living organisms. Moreover its radionuclides may represent an incorporation risk for members of the public and/or radiation workers after a nuclear accident or a release of radioactive materials. However, only few reliable data on Mo biokinetics in humans were available. The results of recent tracer kinetic investigations with stable isotopes have shown several differences from the ICRP data with regard to the processes of intestinal absorption and of excretion. As a consequence, the dose coefficients calculated with a revised biokinetic model deviate from the ICRP estimates. By ingestion of {sup 99}Mo radionuclides with solid food, for example, the dose to the colon may be higher of a factor up to 1 order of magnitude, due to the fraction of non-absorbed material which traverses the gastro-intestinal tract. (orig.) [Deutsch] Molybdaen ist einerseits ein fuer Lebewesen essentielles ...
1998-12-31
International Nuclear Information System (INIS)
Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.
1980-08-01
On the effects of low radiation doses
International Nuclear Information System (INIS)
The prevailing hypothesis of linear extrapolation from high to low radiation doses without any threshold level is being questioned more and more strongly for radiobiological and epidemiological reasons and, consequently, also on socio-economic and ethical grounds. A cost-benefit analysis based on scientific facts and made plausible to the general public, concentrating on a comparison with demonstrable natural and manmade risks, most probably would result not only in the permissible limits being raised by a considerable margin, but also in billions of costs saved, and in greater acceptance of all peaceful uses of radiation, nuclear power included. (orig.)
1998-10-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
Energy Technology Data Exchange (ETDEWEB)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.
2001-05-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
International Nuclear Information System (INIS)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.
2001-05-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
International Nuclear Information System (INIS)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)
2002-01-01
Conformal radiation therapy: technical requirements and clinical applications
International Nuclear Information System (INIS)
Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
In cooperation with NRPB, the specifications of the mainframe COSYMA version 95/1 and the PC COSYMA version 2.0 were prepared and the corresponding modifications implemented. Important improvements are dose-rate dependent models for deterministic health effects, the time dependent efficiency of stable iodine tablets, the extension of data bases for the inclusion of activation products, and supplementary evaluation programs. PC COSYMA has been completed by an economics module, further options in the ingestion pathways, and a graphics package for presenting assessment results. COSYMA has been applied for probabilistic dose assessments within paramter studies and special investigations of EPR concepts. RODOS, the real-time on-line decision support system for nuclear emergency management, has been further developed with the aim of the first pilot version 2.0 for pre-operational application in the second ...
1995-08-01
Review of electron beam therapy physics
Energy Technology Data Exchange (ETDEWEB)
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
2006-07-07
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
Energy Technology Data Exchange (ETDEWEB)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-08-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
International Nuclear Information System (INIS)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-01-01
International Nuclear Information System (INIS)
In this project, measurement of x-ray radiation dose level during radiological examination in Jos university teaching hospital and Plateau State specialist hospital at different locations within the department were carried out using radiation survey meter. The results were converted from micro sievert per hour (#mu#Sv/hr) to milisievert per year (mSv/yr). The radiation levels from the two hospitals visited ranged from 1.3m Sv/yr to 8.4m Sv/yr. This implies that all the radiology departments visited are still operating within the safety limit having less than 20 mSv/yr which is the standard permissible radiation level recommended per year.
2008-10-15
Environmental Radiation Effects: A Need to Question Old Paradigms
Energy Technology Data Exchange (ETDEWEB)
A historical perspective is given of the current paradigm that does not explicitly protect the environment from radiation, but instead, relies on the concept that if dose limits are set to protect humans then the environment is automatically protected as well. We summarize recent international questioning of this paradigm and briefly present three different frameworks for protecting biota that are being considered by the U.S. DOE, the Canadian government and the International Commission on Radiological Protection. We emphasize that an enhanced collaboration is required between what has traditionally been separated disciplines of radiation biology and radiation ecology if we are going to properly address the current environmental radiation problems. We then summarize results generated from an EMSP grant that allowed us to develop a Low Dose Irradiation Facility ...
2003-03-27
Effect of radiation on certain animal viruses in liquid swine manure
International Nuclear Information System (INIS)
The virucidal effect of _6_0Co gamma radiation was studied in cell culture medium and in liquid swine manure involving the most important porcine viruses that can be spread by liquid manure. The radiation doses (20 kGy and 30 kGy) were determined in preliminary experiments employing a porcine enterovirus from the serogroup 1 (Teschen group). In the main experiment, the following viruses were employed: swine vesicular disease (SVD) virus, type C foot-and-mouth disease (FMD) virus, a field strain of Aujeszky's disease (AD) virus, transmissible gastroenteritis (TGE) virus, as well as bovine viral diarrhoea (BVD) virus. The latter strain served as a model for hog cholera virus. The results of the experiments indicate that safe disinfection of the virus infected liquid swine manure by ionizing radiation requires a radiation dose of 30 kGy. (author).
1983-01-01
Development of calibration facility for radiation protection monitoring instruments
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal ...
2008-11-19
Chain radiation-chemical cross-linking of polyethylene under high pressures. [Gamma radiation
Energy Technology Data Exchange (ETDEWEB)
Regularities in the radiation cross-linking of low-density polyethylene under various conditions of ..gamma..-irradiation were studied. It is shown that at the 0.5 GPa pressure and 450 K the gel formation is initiated at doses of about 1 kGy, i.e. at doses 10 times as low as compared to normal conditions. Abnormally high rate of radiation cross-linking at high temperature and high pressure is an evidence of changes in the mechanism of polyethylene, radiation cross-linking, i.e. of the process transition from nonchain to chain conditions. Decrease in the potential barriers of macroradical reactions with macromolecules is the most probable reason of change in the polymer cross-linking nature.
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the only major protection to astronauts from harmful exposure. Unlike low-linear energy transfer (LET) {gamma} or X-rays, the presence of shielding does not always reduce the radiation risks for energetic charged particle exposure, since the dose delivered by the charged particle increases sharply as the particle approaches the end of its range, a position known as the Bragg peak. The Bragg curve does not necessarily represent the biological damage along the particle traversal, and the 'biological Bragg curve' is dependent on the energy and the type of the primary particle, and may vary for different biological endpoints. Here we used a unique irradiation geometry to measure the biological response across the Bragg curve in human fibroblasts ...
2006-10-15
How to assess risk from combined exposures to radiation and other agents?
Energy Technology Data Exchange (ETDEWEB)
Efforts to assess and quantify deleterious effects from toxicants concentrate mainly on single agents whereas real world environmental and occupational exposures to natural and anthropogenic agents entail quite often the concomitant presence of several toxicants. For occupational important exposure situations, combined exposures to physical and chemical agents such as radon and smoking or asbestos and smoking, respectively, were shown to produce over-additive effects at exposure levels typical for earlier workplaces. Already the elucidation of possible health risks from a single agents, its dependence on exposure level, exposure rates, age at exposure and its expression in time is a complex endeavour. Therefore in the past and the present the main emphasis in radiation protection, toxicology, and public health is on the study and assessment of single toxicants. The existing data base on combined effect is rudimentary, mainly descriptive and ...
1997-03-01
Bomb "1"4C and human radiation burden
International Nuclear Information System (INIS)
Following the publication (Stenhouse and Baxter, Nature; 267:828 (1977)) of the levels of bomb "1"4C and the residence times of carbon in the human body, excess radiation burdens from this radioisotope are evaluated under the assumption that no radiation dose, however small, can be regarded as entirely harmless biologically. The estimated annual absorbed dose attributable to "1"4C both natural and man-made for 1953-1973 and similar predicted figures for 1975-2025 are shown graphically. The cumulated doses to gonads (over 30 yr) and to bone marrow and bone-lining cells (over 60 yr) and also estimates of the biological damage to reproductive cells from "1"4C #beta#-irradiation (30 yr accumulated dose) are presented. It is concluded from both genetic and somatic considerations, that the potential human radiation burden due to artificially ...
Radiation hazards from medical applications
International Nuclear Information System (INIS)
An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).
1980-05-31
Health hazards to children due to the Chernobyl accident?
International Nuclear Information System (INIS)
The article tries to assess the radiation effects as objectively as possible. In conclusion, some steps that should be taken in future are listed, as e.g.: continuous monitoring of the radioactivity levels in air and soil, and recording of data for complete information. Further, investigation and assessment of radiation exposure of children, especially in regions most heavily affected; radioactivity monitoring of the food and milk given to children, and scientific research into the problem by pediatrists, and determination of maximum acceptable radiation doses. (orig./HSCH).
British Library Electronic Table of Contents (United Kingdom)
Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...
2011-01-01
Acceptance testing in digital systems of mammography. Protocols applicability
International Nuclear Information System (INIS)
Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure ...
Preparation of polyester/gypsum/composite using gamma radiation, and its radiation stability
Energy Technology Data Exchange (ETDEWEB)
Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of oxygen. Increasing the irradiation ...
2005-06-01
Cluster-loop structure influence on molybdenum radiation hardening
International Nuclear Information System (INIS)
Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).
1990-05-22
Energy Technology Data Exchange (ETDEWEB)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the ...
2010-06-15
International Nuclear Information System (INIS)
Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance ...
2010-06-01
Applications or radiation polymerization hardening to composites
International Nuclear Information System (INIS)
Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at ...
1976-01-01
International Nuclear Information System (INIS)
Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have ...
2006-01-01
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical ...
2007-08-01
Emission of photons by electrons and positrons passing through a thin single crystal
Energy Technology Data Exchange (ETDEWEB)
We consider the radiation of particles (electrons and positrons) undergoing planar channeling in a single crystal of small thickness L. We show that for Lapprox...pi..b/theta/sub L/, where b is the lattice constant and theta/sub L/ is the Lindhard angle, in addition to the principal maxima of spontaneous radiation of channeled particles in the spectrum there are additional interference maxima, and the positions of all maxima of the radiation intensity depend on L. We discuss the dependence of the intensity of radiation at various frequencies on the crystal thickness.
1984-07-01
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for ...
1988-10-01
International Nuclear Information System (INIS)
Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...
2003-10-01
Principles of protection: a formal approach for evaluating dose distributions
International Nuclear Information System (INIS)
One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.
2006-03-01
Preparation of wood-polymer composites using radiation
International Nuclear Information System (INIS)
Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there was no improvement in the mechanical ...
1976-11-25
Effect of some chemicals on the radiation-induced lipid peroxidation
International Nuclear Information System (INIS)
The effect of exposure to gamma rays on LPO contents in liver, spleen and kidney of mice and the anti-lipid-peroxidation of preparations of chinonin, tannic acid and squalene were reported. All these preparations were given by intragastric perfusion. For LPO, a modified method of TBA spectrophotometry was used for determination. The results show that LPO contents in tissues increased 72 h after whole-body exposure of mice to gamma rays, that in range of 0-4 Gy, there was a linear relationship between radiation doses and LPO contents, and that all three preparations were effective in reduction of the LPO content in liver, spleen and kidney of mice, with chinonin (at dose of 0.35 mg/mouse#centre dot#day) being more effective than tannic acid (at dose of 15 mg/mouse#centre dot#day) and squalene (at dose of 0.6 mg/mouse#centre dot#day).
Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given ...
2005-01-01
The elevation of blood levels of zinc protoporphyrin in mice following whole body irradiation
Energy Technology Data Exchange (ETDEWEB)
Elevation of zinc protoporphyrin (ZPP) levels in the blood has served as an indicator of lead poisoning and iron deficiency anemia for many years. We have discovered that sublethal doses of whole body irradiation with x-rays also elevates ZPP 2-3-fold over normal levels. The ZPP level does not begin to increase until days 12-14 postirradiation and peaks between days 18 and 20 before returning to normal levels between days 28 and 35. Increasing the radiation dose delays the onset of the rise in ZPP, but does not affect the magnitude of the elevation. At lethal doses, ZPP elevation is not observed. Neither of the two previously described mechanisms that cause elevations of ZPP, namely iron deficiency and inhibition of ferrochelatase, are responsible for the radiation-induced elevation of ZPP. The elevation of ZPP appears to be correlated with the recovery of the hematopoietic system ...
1984-05-01
Energy Technology Data Exchange (ETDEWEB)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-05-01
International Nuclear Information System (INIS)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-01-01
Normalized noise power spectrum of full field digital mammography detector system
International Nuclear Information System (INIS)
Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)
Normalized Noise Power Spectrum of Full Field Digital Mammography System
International Nuclear Information System (INIS)
A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.
2010-01-05
Detection of irradiated chicken by ESR spectroscopy of bone
Energy Technology Data Exchange (ETDEWEB)
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
1995-10-01
Chemistry and technology of radiation processed composite materials
International Nuclear Information System (INIS)
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut ...
1984-10-01
Chemistry and technology of radiation processed composite materials
International Nuclear Information System (INIS)
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut ...
1984-10-01
Packaging materials for use in radiation processing of foods
International Nuclear Information System (INIS)
In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during ...
Medical irradiation and the use of the 'effective dose equivalent' concept
International Nuclear Information System (INIS)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also ...
1980-03-01
Radiation resistance of nylon. [Gamma radiation
Energy Technology Data Exchange (ETDEWEB)
Various nylons including nylon 6, nylon 66, nylon 610 and nylon 12 in the forms of fiber and film were irradiated with the gamma-ray from Co-60 at the dose rate of 0.12 Mrad/hr in the atmosphere of oxygen at 7 kg/cm/sup 2/ and at the room temperature. The irradiation in vacuum on the same specimens was performed at 0.5 Mrad/hr. The tensile properties and the gel fraction of the irradiated nylon samples were measured, and the radiation resistance of the nylons against the irradiation at low dose rate was estimated. From the experimental results, it became clear that in the case of irradiation in vacuum, all the nylons were durable to the irradiation of 250 Mrad or more, and nylon 6 was more durable than nylon 12, and in the case of irradiation in pressurized oxygen, the radiation resistance of the nylons decreased to one-tenth as compared with that in vacuum, and contrary to that in vacuum, nylon 12 was ...
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
The in situ assembly states of the glucose transport carrier protein in the plasma membrane and in the intracellular (microsomal) storage pool of rat adipocytes were assessed by studying radiation-induced inactivation of the D-glucose-sensitive cytochalasin B binding activities. High energy radiation inactivated the glucose-sensitive cytochalasin B binding of each of these membrane preparations by reducing the total number of the binding sites without affecting the dissociation constant. The reduction in total number of binding sites was analyzed as a function of radiation dose based on target theory, from which a radiation-sensitive mass (target size) was calculated. When the plasma membranes of insulin-treated adipocytes were used, a target size of approximately 58,000 daltons was obtained. For adipocyte microsomal membranes, we obtained target sizes of approximately 112,000 and ...
1987-06-15
Application of low-dose radiation protocols in survey CT scans
International Nuclear Information System (INIS)
Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized ...
2009-08-01
Exposure of Finnish population to solar UV radiation and consequent carcinogenic effects
Energy Technology Data Exchange (ETDEWEB)
Depletion of stratospheric ozone increases irradiance of terrestrial ultraviolet (UV) radiation at short wavelengths, which may be harmful to the human health. To understand quantitatively the risks caused by increasing UV radiation to the Finnish population, the actual UV exposure of the population has to be assessed. It was shown that the snow reflection increases the UV exposure to the face and eyes particularly in the northern Finland. In 1993 exceptionally low ozone levels persisted up to the end of May, which resulted in a theoretical increase in the annual UV dose ranging from 8 % to 13 % in Finland. The maximal increase in the measured erythemally effective dose rate was 34 % on 23 April, when compared with the theoretical normal value. During this study exposure models have been developed. The models have been combined them with Green`s radiation transfer model to estimate ...
1996-12-31
Assessing radiologic risk for population due to human activities
International Nuclear Information System (INIS)
The most important factor in assessing radiologic risk is ensuring scientific means for evaluation of the radioactive release impact upon humans and organisms. To evaluate quantitatively this impact not only knowledge of radioactivity distribution in these dynamical systems is necessary but also understanding the transfer mechanisms between ecosystem components is needed. Thus a complete radioecologic study appear to be very complex and needs defining the source term, dynamic description of radionuclides behavior in the ecosystem, estimation of radiation doses in the major components of the ecosystem and finally the effects of radiation doses upon different parts of the systems. A diagram of the steps implied in evaluation of the effects due to radioactive effluent release in the environment is presented and discussed. The following steps are described: - identification of radioactive sources, as well ...
2002-09-06
International Nuclear Information System (INIS)
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. ...
Equipment hardening and hardness assurance
International Nuclear Information System (INIS)
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to ...
Single event effects in the pixel readout chip for BTeV
Energy Technology Data Exchange (ETDEWEB)
In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.
2001-12-07
International trends in radiation protection
International Nuclear Information System (INIS)
The great uranium debate throughout the industrialised world has intensified awareness of the biological hazards from ionizing radiation. It is therefore appropriate to use this awareness to draw attention to medical X-Radiation which today represents the most significant risk to future generations. There is ample legislation to control proliferation of nuclear development but in diagnostic radiology proliferation is unlimited; most international surveys indicate an unchecked annual growth rate of 15%. The article looks at risk hypotheses, dose measurements and the responsibilities of practising radiographers, and also reviews the international situation as reported at the 1977 world congress of radiation protection.
Population doses from beam-therapy in Japan, 1978, 3
International Nuclear Information System (INIS)
As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three ...
1981-01-01
Estimations of population doses and risk estimates from occupational exposures in Japan, 1978, 2
International Nuclear Information System (INIS)
The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 ...
2006-07-01
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide ...
2003-01-01
Radiation therapy and Ewing's sarcoma in childhood
International Nuclear Information System (INIS)
Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.
Energy Technology Data Exchange (ETDEWEB)
Using the radiation chemical method it is possible to prepare wood-plastic composites using doses of 1 to 2.5 kGy. The impregnation mixture in the wood gelatinates and subsequent curing using chemical initiators takes place without outflow of the mixture from the wood and without formation of incrustations. The basic components of the impregnation mixtures used were unsaturated polyester resins; styrene or methyl methacrylate was used as the thinner. The proven initiator of polymerization was 2,2'-azobisisobutyronitrile. The technology is described of wood impregnation and radiation or chemical curing. The effects were monitored of viscosity, temperature, radiation dose and the concentrations of the individual components of the impregnation mixtures and initiators of polymerization on the process of the preparation of wood-plastic composites.
1983-06-01
Effect of ionizing radiation on the properties of PLA packaging materials
International Nuclear Information System (INIS)
Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)
Energy Technology Data Exchange (ETDEWEB)
Radiation protection programs for workers are based, in the United States, on a hierarchy of limitations stemming from Federal guidance approved by the President. This guidance, which consists of principles, policies, and numerical primary guides, is used by Federal agencies as the basis for developing and implementing their own regulatory standards. The primary guides are usually expressed in terms of limiting doses to workers. The protection of workers against taking radioactive materials into the body, however, is accomplished largely through the use of regulations based on derived guides expressed in terms of quantities or concentrations of radionuclides. The values of these derived guides are chosen so as to assure that workers in work environments that conform to them are unlikely to receive radiation doses that exceed the primary guides. The purpose of the present report is to set forth derived ...
1988-09-01
Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki
International Nuclear Information System (INIS)
For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air ...
1980-01-01
Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system
International Nuclear Information System (INIS)
The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin ...
2001-02-01
Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983
International Nuclear Information System (INIS)
Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be ...
1988-01-01
Salmonella radicidation of poultry carcasses
International Nuclear Information System (INIS)
This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were ...
2005-09-22
Radioactivity of Tobacco Leaves and Radiation Dose Induced from Smoking
UK PubMed Central (United Kingdom)
The radioactivity in tobacco leaves collected from 15 different regions of Greece and before cigarette production was studied in order to find out any association between the root uptake of radionuclides...Full Text Available
2009-02-01
Radiation grafting processes and properties of leathers modified with butyl acrylate
International Nuclear Information System (INIS)
Conditions for radiation induced grafting with butyl acrylate dispersed in water emulsion onto chrome-tanned pig skins have been worked out for #gamma#-rays and electron beam irradiations. The highest yield of grafting was observed at monomer concentration approximately 25% (w/w), dose equal to 25 kGy and dose rate not exceeding 10 MGy/h. At these conditions the yield of grafting attained a value approximately 25% and content of homopolymer in the leather amounted to 6%. The efficiency of monomer to polymer conversion decreases when the concentration of monomer in emulsion and dose rate increases. Yield of homopolymer is independent of the dose rate. An explanation of the observed relations has been proposed. The physical and used properties of grafted leathers were tested. Radiation processed leathers were found superior to samples finished by traditional ...
1982-01-01
Low dose effects - is the fear more dangerous than the radiation?
Energy Technology Data Exchange (ETDEWEB)
The use of hypothesis which assumes a dose / harmful effect relationship without a limit allows the calculation of risks attributable to doses too small to produce detectable, harmful biological effects. The daughter product of this hypothesis is ALARA concept which requires that the dose received is kept as low as reasonably achievable. This concept of prudent avoidance is generally accepted by international radiation protection organisations and universally applied by radiation health professionals. The acceptance of a hypothesis which assumes that a single nuclear event can cause carcinogenesis, has generated levels of anxiety which may have resulted in significant detriment to those possibly exposed to ionising radiation. The anxiety generated may have caused more detriment and a higher death rate than the worst case ` theoretical` value calculated using the ...
1996-01-01
Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses
UK PubMed Central (United Kingdom)
DNA double-strand breaks (DSBs) are generally accepted to be the most biologically significant lesion by which ionizing radiation causes cancer and hereditary disease. However, no information on the...Full Text Available
2003-04-29
Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...
1981-01-01
Elimination of organics chemicals in aqueous solutions by gamma radiation processing
International Nuclear Information System (INIS)
The objective this work was to evaluate the gamma radiation processing for elimination of organic contaminants on industrial wastewater. Standard samples with 17 hydrocarbons (acetophenone, anisole, benzene, chlorobenzene, cyclohexanone, N, N-dimethylaniline, phenol, naphtalene, 1-chloronaphtalene, n-octadecane, p-nitrotoluene, toluene, tetrachloroethane, tetramethylbenzene, n-undecane, m-xylene and o-xylene) was preparated in hexane with total concentration of 1 #mu# g/ #mu# l which was analyzed by gas chromatography. Other sample with the same concentration of these hydrocarbons in acetone was used to contaminate water samples, which were irradiated with gamma radiation from Co-60 between doses 5.0 to 20.0 KGy and dose rate of 1.162 KGy/h. The activity of source was 1470 Ci. Percents destruction of hydrocarbons were: 79.76 % to 5.0 KGy, 85.97 % to 7.5 KGy, 86.24 % to 10.0 KGy, 86.72 % to 12.5 KGy, ...
1992-08-16
UK PubMed Central (United Kingdom)
BackgroundTo compare the differences in dose-volume data among coplanar intensity modulated radiotherapy (IMRT), noncoplanar IMRT, and helical tomotherapy (HT) among patients with...Full Text Available
... Regine, Nader Hanna, Michael C. Garofalo, Austin Doyle, Susanne Arnold, Ritesh Kataria, Jacqueline Sims, Ming Tan, Mohammed Mohiuddin. ( ... ...
Clinical implementation of a convolution based algorithm for 3D treatment planning
International Nuclear Information System (INIS)
Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and ...
International Nuclear Information System (INIS)
With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems ...
2007-05-01
Radiation induced micrencephaly in guinea pigs
International Nuclear Information System (INIS)
A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays ...
2006-04-20
On the determination of the dose-area product during X-ray examinations
International Nuclear Information System (INIS)
Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability ...
Energy Technology Data Exchange (ETDEWEB)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin ...
2010-07-01
Estimation of dose in irradiated chicken bone by ESR method
Energy Technology Data Exchange (ETDEWEB)
The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was {gamma}-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated doses of chicken bones ...
1998-03-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the ...
2010-10-01
International Nuclear Information System (INIS)
Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in ...
2002-10-20
Study of total ionizing dose radiation effects on nitride/oxide stack gate MOS capacitor
International Nuclear Information System (INIS)
The aim of this paper is to investigate the total ionizing dose (TID) radiation effects on MOS capacitor with nitride/oxide stack gate. The stack gate MOS capacitors are fabricated with 20 nm oxide, 40 nm nitride or 110 nm nitride respectively. Through the analysis of CV curve of the irradiation capacitors, it is found that the degradation of the CV curve is due to a significant increase of interface traps and somewhat smaller oxide charge. It is also shown that the thicker of the nitride, more interface traps and oxide charge will be occurred. (authors)
2008-07-01
International Nuclear Information System (INIS)
Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.
1999-04-01
Estimated values of the genetic and somatic radiation exposure of the Bulgarian population in 1976
International Nuclear Information System (INIS)
The genetically and leukemia-significant doses (GSD and LSD) were calculated from the average gonad and bone marrow doses caused by the most frequently applied radiopharmaceuticals in Bulgaria in 1976. Because of the lack of information about the age groups of the patients examined assumptions have been made which led to estimated values of 0.97 mrad for GSD and 2.0 mrad for LSD which must be considered as the upper limit of the real GSD and LSD. The influence of the different radiopharmaceuticals on the average radiation exposure of the population is discussed. (author).
1976-01-01
Comparison of Atmospheric Dispersion Models Between PHWR and PWR
International Nuclear Information System (INIS)
The radiation dose and the atmospheric dispersion for Pressurized Heavy Water Reactors (PHWR) are based on the CAN/CSA N288.2-M91 standards: for Pressurized Water Reactor (PWR) on the NRC Regulatory Guide 1.145. There are some differences between in the methodologies used in the standards, including the atmospheric dispersion model, the release height, the temperature lapse rate, the cutoff condition. This paper reports on a comparison of standards for atmospheric dispersion models of PHWRs and PWRs in order to determine which one is the more conservative. The comparison between PHWR and PWR for atmospheric dispersion factors and radiation doses confirms that there are no big differences
2010-10-01
C-14 release and transport from a nuclear waste repository in an unsaturated medium
Energy Technology Data Exchange (ETDEWEB)
The release of {sup 14}C as {sup 14}CO{sub 2} from partly failed spent fuel containers has been analyzed by the flow of gases into and out of the containers. This flow of gases is driven by pressure differences, which are in turn caused by heating by the spent fuel. In this analysis, the timing and size of holes in the containers are assumed to be given. A better means of predicting the time distribution and sizes of penetrations in nuclear waste containers is needed. For the purposes of far-field transport calculations, we have adopted release rates that are shown to be bonding for the large range of hole sizes studied. The transport of released {sup 14}CO{sub 2} has been analyzed by transport in equivalent porous medium. The peak {sup 14}CO{sub 2} concentration in pore gas at 350 m above the repository does not depend on the time of hole occurrence, although the time of penetration obviously affects the arrival and duration of exposure to {sup 14}C. Nor does ...
1990-06-01
SSRM characterisation of FIB induced damage in silicon
International Nuclear Information System (INIS)
Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.
2008-03-01
Radiation hardening of final optics for an ICF reactor
International Nuclear Information System (INIS)
Radiation damage of the final optical components in an Inertial Confinement Fusion (ICF) reactor is a crucial issue for development of a laser-fusion reactor. To some extent, this problem will be encountered in the National Ignition Facility (NIF), but there, the integrated radiation dose will be considerably less than that encountered in a future reactor. This extremely harsh radiation environment necessitates shielding the ICF optics from direct neutron and x-ray bombardment. Several approaches have been suggested, such as the use of grazing incidence metal mirrors or fused silica wedge deflectors. While metal mirrors can withstand a larger radiation dose, their focusing qualities pose problems. Therefore wedge deflectors, originally suggested by Lawrence Livermore National Laboratory (LLNL) staff, represent a promising alternative. ...
1995-04-24
Effect of antioxidants on aging of nuclear plant cable insulation
International Nuclear Information System (INIS)
The effects of various antioxidants and antioxidant concentrations on the radiation and thermal stability of EPDM and XLPE polymers used for insulation of electric cable in nuclear power plants were measured. The objective was to determine if particular antioxidants could be identified as being especially effective for stabilization against radiation aging and combined thermal and radiation aging. Elongation to rupture was used as the measure of stability. Materials were irradiated to doses up to 2 MGy (200 Mrad) at a dose rate of 200 to 300 Gy/h in the Cobalt-60 Gamma Irradiation Facility at the University of Virginia. All of the antioxidants tested, which were known to provide excellent thermal stability, also provided good stability for radiation aging and combined thermal/radiation aging, although small differences between antioxidants ...
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous ...
2008-05-01
International Nuclear Information System (INIS)
The distribution of radiation dose commitments within the body that can result from the lung deposition of a number of transuranic radionuclides ("2"3"7Pu, "2"3"8Pu, "2"3"9Pu, "2"4"0Pu, "2"4"1Pu, "2"4"2Pu, "2"4"3Pu, "2"4"4Pu, "2"4"1Am, "2"4"2Am, "2"4"3Am, "2"4"4Am, "2"4"2Cm, "2"4"3Cm, "2"4"4Cm, and "2"4"6Cm) was calculated. The variables that influence these organ dose commitments include the mobility of the particle or its dissolution products within the body, the radiation characteristics of the inhaled radionuclides and their progeny, and the size of the particles inhaled. In the calculation of organ dose commitments for whole-body, lungs, liver, bone tissues, kidneys, and gastrointestinal tract from the inhalation of transuranium radionuclides, physical characteristics of importance are the dimensions of the particle, its aerodynamic properties, and its density. For particles ...
1975-11-17
Effect of rapid thermal annealing on radiation hardening of MOS devices
International Nuclear Information System (INIS)
The influence of RTA (Rapid Thermal Anneal) treatment on MOS radiation hardness is demonstrated and compared with classical furnace treatment. In the case of the RTA, the oxide trapped charge is found to depend on: (i) the anneal temperature as expected, data are in good agreement with a recently developed model of oxygen out-diffusion; (ii) the location across the wafer with a radial dependence, results could be related to stress induced by thermal gradient.
1995-07-17
Energy Technology Data Exchange (ETDEWEB)
Conference abstract book contains seven sections: Plenary-4 abstracts; Chemical-9 abstracts; Radiation-7 abstracts; Ultra Low Doses and Medicine-6 abstracts; Biomedical-11 abstracts; Risk Assessment-5 abstracts and Poster Sessions-25 abstracts. Each abstract was provided by the author/presenter participating in the conference.
2002-05-28
International Nuclear Information System (INIS)
1. It is not possible to give a threshold value for the dose - nor for genetic neither for somatic late effects. 2. The linear dose-effect exprapolation is not conservative in the sense of 'fying on the safe side'. 3. There has been found no relative reduction of the effects at chronic radiation exposure in man. 4 The numbers given by authorities and utilities for damage rates per rem received, that are called upper limits, are by far too low. (orig./HP).
1980-02-01
International Nuclear Information System (INIS)
The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.
The application of Geant4 simulation code for brachytherapy treatment
Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.
2000-01-01
International Nuclear Information System (INIS)
The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity ...
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
This study evaluates the effect of gamma radiation on the viability of fungi and actinomycetes that contaminate medicinal plants. The relationship between the total lipids of some fungi and actinomycetes and their sensitivity to gamma radiation is also investigated. The data reveal that the viable counts of these florae decrease approximately exponentially with the radiation dose, the effective dose for the elimination of these microorganisms being about 5 kGy for all the medicinal plants under study. Response of pure cultures of fungi and actinomycetes isolated from medicinal plants to increasing absorbed doses of gamma radiation indicate that an increase in radioresistance is in the following order: Streptomyces rimosus, Fusarium solani, Nocardia kuroishii. F. oxysporum, A. fumigatus, A. flavus, A. parasiticus and A. ochraceus. The total ...
1997-01-01
Acceleration of particles in pulsar magnetosphere and the X-ray radiation
The available data of single X-ray pulsars, their wind nebulae, and the SNRs which are connected to some of these sources are analysed. It is shown that electric field intensity of neutron stars tears off charged particles from the surface of neutron star and triggers the acceleration of particles. The charged particles are accelerated mainly in the field of magnetodipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magnetodipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
2004-01-01
Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
Energy Technology Data Exchange (ETDEWEB)
For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped ...
2006-02-07
Protein Targets of Reactive Metabolites of Thiobenzamide in Rat Liver In Vivo
UK PubMed Central (United Kingdom)
Thiobenzamide (TB) is a potent hepatotoxin in rats, causing dose-dependent hyperbilirubinemia, steatosis, and centrolobular necrosis. These effects arise subsequent to and appear to result from...Full Text Available
2008-07-01
UK PubMed Central (United Kingdom)
Neuropilin-1 (NRP1) acts as a co-receptor for class 3 semaphorins and vascular endothelial growth factor and is an attractive angiogenesis target for cancer therapy. In addition to the transmembrane...Full Text Available
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
In this experiments, we established long-termed culture methods of bone marrow stromal cells for proliferation and differentiation of stem cells. And we selected some extracts which support maximal proliferation of stromal cells with this method. We conformed the synergic effects of herbal mixture extracts for stromal cell growth. The proliferation of stromal cells was increased rather by the addition of mixture extracts than by addition of single strain extract. In the previous and cooperative experiments, we selected complex extracts (Him-I, Him-II) which increased the number of nonadherent mononuclear cells. Different cytokine expression patterns were observed stromal cells cultured in the presence or absence of mixture extracts which support differentiation of nonadherent cells. Some fractions of Him-I and Him-II increased the proliferation of bone marrow cells irradiated {gamma}-ray(4Gray). Stimulation of macrophage cell line with herval extracts with the treatments of recombinant ...
2000-04-01
International Nuclear Information System (INIS)
Thirty-seven patients with primary nonresectable intrahepatic cholangiocarcinoma (57% with prior treatment and/or metastasis) were prospectively treated with external radiation, chemotherapy, and "1"3"1I labelled anti-CEA. Therapy began in all trials with whole liver irradiation (21.0 Gy, 3.0 Gy/Fx, 4 days/week, 10 MV photons) with alternate treatment day chemotherapy (Adriamycin, 15 mg + 5-FU, 500 mg). One month after external beam therapy, chemotherapy was given (Adriamycin, 15 mg + 5-FU, 500 mg) followed the next day by the first administration of "1"3"1I anti-CEA. The treatment schedule used was 20 mCi day 0; 10 mCi day 5 as an outpatient. This schedule was derived from tumor dose estimates which indicated that 20 mCi (8-10 mCi/mg IgG) was sufficient to achieve tumor saturation with a tumor effective half-life of 3 to 5 days, depending upon the species of animal from which the antibody was obtained. The median tumor ...
Solar flux distribution in cavity receivers with parabolic dish collector
Energy Technology Data Exchange (ETDEWEB)
Thermal absorption with its combined thermal and mechanical loads in a solar receiver does depend significantly on the distribution of incident solar radiation. For a cavity receiver with paraboloid collectar a method is derived which enables the calculation of solar radiation distribution on the areas inside the receiver. The theoretical bases are presented first, and a subsequent example shows the influence of the most important geometric parameters on the distribution of solar radiation.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).
1990-01-01
International Nuclear Information System (INIS)
The influence of electron-beam irradiation on mechanical properties of commercial multilayer flexible packaging materials based on coextruded and laminated polypropylene (PP), low-density polyethylene (LDPE), ethylene vinyl alcohol copolymer (EVOH) and poly(ethylene terephthalate) (PET), irradiated with doses up to 120 kGy, was studied. The tensile strength and elongation at break of the irradiated PET/PP film increase, while the penetration and sealing resistance decreased. In addition, the irradiated PET/LDPE/EVOH/LDPE film presented increase in the tensile strength on some radiation doses and decrease of the penetration and sealing resistance, except for sealing resistance at radiation dose of 15 kGy that resulted in a slight increase of ca 4%.
2008-09-21
Radiation tolerant GaAs MESFET with a highly-doped thin active layer grown by OMVPE
International Nuclear Information System (INIS)
A new structure of GaAs MESFET with high radiation tolerance is proposed. Changes in electrical parameters of a GaAs MESFET as a function of total #gamma#-ray dose have been found to be caused mainly by a decrease in the effective carrier concentration in an active layer. The authors have designed a new structure from a simulation based on an empirical relationship between the changes of the effective carrier concentration and the total #gamma#-ray dose. It has been successfully demonstrated by utilizing a highly-doped thin active layer (4 x 10"1"8 cm"-"3, 100 Angstrom) grown by OMVPE. This MESFET can withstand a dose ten times higher [1 x 10"9 rads(GaAs)] than a conventional one can.
1990-07-16
Ramsar, a city in the northern Iran, has the highest level of natural background radiation in the world. It has been clearly shown that low doses of ionising radiation can induce resistance to subsequent higher exposures. This phenomenon is termed radioadaptive response. We have compared induction of cytogenetic radioadaptive response by High Natural Background Radiation (HNBR) in Ramsar and X-ray occupational exposure as conditioning doses in human peripheral blood lymphocytes. 30 healthy control individuals, living in Ramsar but in normal background radiation areas, 15 healthy individuals from Talesh Mahalleh, a region with extraordinary high level of background radiation, and 7 X-ray radiographers working in Ramsar hospital located in normal natural background ionising radiation area were evaluated. Peripheral blood ...
2003-01-01
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate ...
2008-10-01
International Nuclear Information System (INIS)
The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for dynamic compartment model (GACOM) is developed for the nuclide migration and the ...
1999-02-01
British Library Electronic Table of Contents (United Kingdom)
We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.
2011-01-01
UK PubMed Central (United Kingdom)
The titers of several preparations of kuru. Creutzfeldt-Jacob disease, and scrapie viruses were reduced by only 1/10th or less by high doses of gamma radiation of 50 kGy and by only 1/10th-1/1000th...Full Text Available
1978-12-01
Sources of X-rays in school; Zrodla promieniowania rentgenowskiego w szkole
Energy Technology Data Exchange (ETDEWEB)
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gas discharges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
1996-12-31
Serious radiation accidents and the radiological impact on agriculture
International Nuclear Information System (INIS)
The consumption of food products obtained in areas subjected to radioactive contamination as a consequence of a radiation accident appears to be the most significant source of irradiation for the population. At the same time, this route can be regulated very effectively. The regularities of contamination of agricultural production, peculiar features of internal dose formation in the population and the effectiveness of countermeasures in agriculture have been analysed using the experience of two major accidents in the former USSR - in the South Urals (Kyshtym accident) in 1957, and at the Chernobyl NPP in 1986. (Author).
Radiation hardening of a high voltage IC technology (BCDMOS)
International Nuclear Information System (INIS)
A program was undertaken to radiation harden an existing power integrated circuit technology (BCDMOS) to total dose, gamma dot, SEU, and neutrons. Efforts have centered around hardening and optimizing our CMOS, DMOS, and NPN devices. Initial results indicate a substantial improvement in hardness over our existing commercial technology.
1990-07-16
Biological effects and health risks following to the exposition to ionizing radiation
International Nuclear Information System (INIS)
Late somatic and genetic radiation effects are imperfectly understood, particularly in the human species. However the available information is sufficient to draw reasonably precise risk estimates in man for many types of damage by means of scientifically justifiable procedures and with the necessary caution. This overall absolute risk of major somatic and genetic damage may be set at around 10"-"4/rad of chronic whole-body doses.
1976-01-01
Assessment of internal contamination due to gamma emitters at nuclear power stations of Tarapur
International Nuclear Information System (INIS)
Personal monitoring and dose assessment of all radiation workers is an essential regulatory requirement as per radiation safety procedures of AERB and operating stations. The occupational workers of TAPS 1 and 2 and TAPS 3 and 4 are monitored for internal contamination due to high energy gamma emitters by whole body counting
2010-02-03
Advanced composite materials made by radiation processing
Energy Technology Data Exchange (ETDEWEB)
An industrial EB processing line is started to produce cement-bound /CB/ chipboard with radiation cured acrylic coating. The basic features of this line are presented here. The main technological parameters of coating such as: effect of oligomer- and monomer reactivity, monomer functionality, dose-rate and inerting atmosphere on the progress of curing have been discussed. The EB processed CB board is an advanced composite material for the modern lightweight architecture.
1988-01-01
International Nuclear Information System (INIS)
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose ...
PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting ...
2011-05-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients ...
2009-10-15
Prenatal exposure to ionizing radiation and subsequent development of seizures
International Nuclear Information System (INIS)
Seizures are a frequent sequela of impaired brain development and can be expected to affect more children with radiation-related brain damage than children without such damage. This report deals with the incidence and type of seizures among survivors prenatally exposed to the atomic bombing of Hiroshima and Nagasaki, and their association with specific stages of prenatal development at the time of irradiation. Fetal radiation dose was assumed to be equal to the dose to the maternal uterus. Seizures here include all references in the clinical record to seizure, epilepsy, or convulsion. Histories of seizures were obtained at biennial routine clinical examinations starting at about the age of 2 years. These clinical records were used to classify seizures as febrile or unprovoked (without precipitating cause). No seizures were ascertained among subjects exposed 0-7 weeks after fertilization at ...
Energy Technology Data Exchange (ETDEWEB)
Nineteen-day-old dwarf sunflower plants (Helianthus annuus, variety NK894) received a variable dose (0-40 Gy) from a cobalt-60 gamma source. A very sensitive stem monitoring device, developed at Battelle's Pacific Northwest Laboratories, Richland, Washington was used to measure real-time changes in stem diameter. Exposure of plants caused a significant reduction in stem growth and root biomass. Doses as low as 5 Gy resulted in a significant increase in leaf density, suggesting that nonreversible morphological growth changes could be induced by very low doses of radiation. Carbohydrate analysis of 40-Gy irradiated plants demonstrated significantly more starch content in leaves and significantly less starch content in stems 18 days after exposure than did control plants. In contrast, the carbohydrate content in roots of 40-Gy irradiated plants were not significantly different from unirradiated ...
1988-05-25
Adaptive response of the chicken embryo to low doses of x-irradiation
Energy Technology Data Exchange (ETDEWEB)
Chicken embryos were x-irradiated in ovo with 5-30 cGy (=priming dose) at the 13th-15th day of development. After 3-48 h, brain- and liver-cell suspensions were x-irradiated in vitro with (challenge) doses of 4-32 Gy. Significantly less radiation damage was observed when the radiation response was measured by scheduled DNA synthesis, nucleoid sedimentation and viscosity of alkaline cell lysates 12-36 h after the priming exposure. In vivo, pre-irradiation with 10 cGy enhanced regeneration as evidenced by the DNA content of chicken embryo brain and liver 24 h following a challenge dose of 4 Gy. From nucleoid sedimentation analyses in brain and liver cells immediately after irradiation with 16 Gy and after a 30-min repair period in the presence of aphidicolin, dideoxythymidine and 3-aminobenzamide or in the absence of these DNA repair inhibitors, it is concluded that a reduction of the ...
1995-08-01
International Nuclear Information System (INIS)
This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical ...
2003-06-01
International Nuclear Information System (INIS)
The synthetic process of polyethylene cation exchange capillary via radiation grafting polystyrene by simultaneous irradiation with "6"0Co #gamma#-ray source and sulfonation with concentrated H_2SO_4 was studied. The effects of dose, dose rate, monomer concentration, solvents, temperature and crosslinking agents on the graft copolymerization of styrene with polyethylene capillary were illustrated. The relationship between the radiation grafting conditions and the properties of ion-exchange capillary were examined. A polyethylene cation exchange capillary with I.D. 0.8 mm, length 20 m, exchange capacity 0.7 Meq/g 60% capacity in 10 s (flow rate 20 ml/min) was prepared. No significant loss of copacity was found from this ion-exchange capillary after 200 adsorption/regeneration cycles.
Radiation processed composite materials of wood and elastic polyester resins
International Nuclear Information System (INIS)
The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of ...
1982-09-19
International Nuclear Information System (INIS)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
Measurement of liquid nitrogen level by radiation
Energy Technology Data Exchange (ETDEWEB)
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
1995-07-01
International Nuclear Information System (INIS)
Efforts are being made to determine a gamma radiation dose for mortality of third-instar larvae of Anastrepha fraterculus which infest mangos of the Haden variety of 400 g weight. Four radiation treatments were tested: 0.4 kGy, 0.6 kGy, 0.8 kGy and 1.0 kGy. Using as a criterium for mortality the interruption of the biological cycle between larva and pupa, the following results were achieved: 49.61%, 63.33%, 74.86% and 90.72%. The percentages obtained have been corrected using the Abbot formula. When the criterium was based on no adult emergence, 100% mortality was achieved for the four treatments. (author)
1999-01-01
Assessment and control of fetal exposure
Energy Technology Data Exchange (ETDEWEB)
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose ...
1991-10-01
Study of radionuclide contributing to dose rates in 540 MWe plant environment
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat ...
2005-11-23
International Nuclear Information System (INIS)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including ...
Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy
International Nuclear Information System (INIS)
Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin ...
2010-08-18
The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)
International Nuclear Information System (INIS)
As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.
Radiation hardening of semiconductor parts
International Nuclear Information System (INIS)
This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.
Energy Technology Data Exchange (ETDEWEB)
Inactivation of aflatoxin B1 was studied by using gamma radiation and hydrogen peroxide. A 100-krad dose of gamma radiation was sufficient to inactivate 50 micrograms of aflatoxin B1 in the presence of 5% hydrogen peroxide, and 400 krad was required for total degradation of 100 micrograms of aflatoxin in the same system. Degradation of aflatoxin B1 was confirmed by high-pressure liquid chromatographic and thin-layer chromatographic analysis. Ames microsomal mutagenicity test showed loss of aflatoxin activity. This method of detoxification also reduces the toxin levels effectively in artificially contaminated groundnuts.
1989-02-01
Accelerated-aging tests for predicting radiation degradation of organic materials
Energy Technology Data Exchange (ETDEWEB)
Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.
1984-03-01
Accelerated-aging tests for predicting radiation degradation of organic materials
International Nuclear Information System (INIS)
Long-term aging of organic materials in reactor containment buildings has become a major issue within the nuclear community. In this article, the status of radiation-aging qualification test requirements in several countries is reviewed, and problems with the current aging methodologies are described. These problems include dose-rate and synergistic effects and environmental synergisms, which have been found for many different polymeric materials. A number of approaches to improved accelerated-radiation-aging tests for prediction of long-term aging behavior are discussed together with their limitations.
1984-01-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...
2011-01-01
International Nuclear Information System (INIS)
During the normal operation of a Nuclear Power Plant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear power plant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)
2005-11-23
Improvement of wood quality used in Syria by irradiation polymerization
International Nuclear Information System (INIS)
Wood plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, and with Okoume (aucoumea klaineana pierre) imported to Syria in large quantities. Three monomer systems; acrylamide, butylmethacrylate, and styrene were used. polymerization was induced at various radiation doses (10, 20, and 30 kGy) to study the role of radiation doses using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength or tensile strength of the obtained wood polymer composites (WPC) were studied. The effect of the additives, sulfuric acid (H"+), N-vinyl pyrrolidone (NVP), trimethyolpropane triacrylate (TMPTA), urea (U), lithium nitrate (LiNo_3), copper sulfate (CuSO_4) and co-additives on monomer system polymerization were also investigated. Methanol, water and water/methanol mixtures were used as the swelling agents. In ...
2010-04-01
Gene expression analysis after low dose ionising radiation exposure of the developing organism
International Nuclear Information System (INIS)
Measuring gene expression using microarrays is relevant to many areas of biology and medicine, such as follow up of developmental stages and diseases onset, and treatment study. Since there can be tens of thousands of distinct probes on an array, each micro array experiment can accomplish the equivalent number of genetic tests in parallel. Arrays have therefore dramatically accelerated many types of investigations. For example, microarrays can be used to identify stress response genes by comparing gene expression in challenged versus normal cells. In the Molecular and Cellular Biology lab (MCB), the micro array experiments are performed within the Genomic Platform, fully equipped to analyse either the behaviour of bacteria during long space flight, the effect of low dose ionising radiation on the developing organism in mice, or the human individual radiation sensitivity. For the low dose effect, two ...
2007-09-01
Problems involved in developing an index of harm
International Nuclear Information System (INIS)
Death as a criterion (age distribution of occupational death; mean loss of life years due to radiation deaths); accidents at work (incidence of accidents of certain degrees of severity); total loss of working days due to accidents; occupational diseases; somatic and genetic radiation effects; radiation effects during pregnancy (incidence of pregnancies, ristes before implantation, hazards to the embryo, hazards to the foetus, total additional risk due to radiation exposure during pregnancy); age and sex dependence of risk figures; attempted formulation of an index of harm. (HP/orig.).
1979-01-01
Modeling human risk: Cell & molecular biology in context
Energy Technology Data Exchange (ETDEWEB)
It is anticipated that early in the next century manned missions into outer space will occur, with a mission to Mars scheduled between 2015 and 2020. However, before such missions can be undertaken, a realistic estimation of the potential risks to the flight crews is required. One of the uncertainties remaining in this risk estimation is that posed by the effects of exposure to the radiation environment of outer space. Although the composition of this environment is fairly well understood, the biological effects arising from exposure to it are not. The reasons for this are three-fold: (1) A small but highly significant component of the radiation spectrum in outer space consists of highly charged, high energy (HZE) particles which are not routinely experienced on earth, and for which there are insufficient data on biological effects; (2) Most studies on the biological effects of radiation to date have been ...
1997-06-01
International Nuclear Information System (INIS)
A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was ...
2001-03-01
The preliminary success of ALARA implementation in Daya Bay NPP
International Nuclear Information System (INIS)
Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant procedures, ALARA coordination organization on plant level and for ...
2000-05-01
Tertiary-Butanol: A toxicological review
British Library Electronic Table of Contents (United Kingdom)
Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
ObjectiveTo study a method of chemical sterilization and its efficacy in adult male stray dogs.MethodsSterilization was performed 45 days after a single bilateral intratesticular injection of calcium chloride (CaCl2) at the doses of 5, 10, 15 or 20 mg per testis per kg body weight.ResultsHistomorphological measures of testes showed total necrosis of testicular tissue at 45 days after an injection of either 10 or 15 or 20 mg CaCl2 along with fibrosis and hyalinization in seminiferous tubules and interstitial spaces. Infiltration of leucocytes was also observed with the 10- or 15-mg dose. Disintegration of germ cell arrangement in seminiferous tubules and washing out of germ cells from the tubules were noted with the 5-mg dose. Relative organ weight, epididymal sperm count, plasma and intrat...
2007-01-01
Photoluminescence Decay of Irradiated Herbs
Energy Technology Data Exchange (ETDEWEB)
Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt){sup -P}. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)
1999-07-01
Photoluminescence Decay of Irradiated Herbs
International Nuclear Information System (INIS)
Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt)"-"P. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)
1998-07-05
Magnetospheric particle acceleration and X-ray emission of pulsars
The available data on isolated X-ray pulsars, their wind nebulae, and the supernova remnants which are connected to some of these sources are analyzed. It is shown that electric fields of neutron stars tear off charged particles from the surface of neutron star and trigger the acceleration of particles. The charged particles are accelerated mainly in the field of magneto-dipole radiation wave. Power and energy spectra of the charged particles depend on the strength of the magneto-dipole radiation. Therefore, the X-ray radiation is strongly dependent on the rate of rotational energy loss and weakly dependent on the electric field intensity. Coulomb interaction between the charged particles is the main factor for the energy loss and the X-ray spectra of the charged particles.
2007-01-01
International Nuclear Information System (INIS)
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover ...
2006-11-13
Pharmacokinetic and dosimetric characteristics of some thallium isotopes
International Nuclear Information System (INIS)
Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the ...
Design modifications in 540 MWe and its impact on the dose rates
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements ...
2005-11-23
British Library Electronic Table of Contents (United Kingdom)
A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...
2011-01-01
Vildagliptin is a potent and selective dipeptidyl peptidase IV inhibitor in development for the treatment of type 2 diabetes that improves glycemic control by enhancing alpha- and beta-cell responsiveness to glucose. Two open-label, single-dose, randomized, crossover studies in healthy subjects (ages 18-45 years) investigated the dose proportionality of vildagliptin pharmacokinetics (n = 20) and the effect of food (n = 24) on vildagliptin pharmacokinetics. There was a linear relationship (r(2) = 0.999) between vildagliptin doses of 25, 50, 100, and 200 mg and area under the plasma concentration-time curve from time zero to infinity (AUC(0-infinity)) and maximum plasma concentration (C(max)). Dose proportionality was assessed using a statistical power model [X = alpha x (dose)(beta)]. The 90% confidence intervals of the proportionality coefficient, beta, for AUC(0-infinity) ...
2007-07-26
International Nuclear Information System (INIS)
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs ...
2004-07-01
Age and carcinogenesis of "2"3"9Pu
International Nuclear Information System (INIS)
The late effects of "2"3"9Pu have been studied after its administration to perinatal, juvenile and adult rats. Adults and weanlings were injected intravenously, newborns intracardially and 19-day foetuses by intravenous injection of the dam. Dose levels were selected to deliver radiation doses of approximately 7, 23, or 70 rads to the femur of all ages during the first 10 days post injection; in general these values were achieved as shown by tissue analysis. Dose rates subsequently diverged, resulting in widely varying cumulative radiation doses for the four age groups. Survival times of rats exposed post-natally were progressively decreased by increasing dose. No decrement in survival was found for those exposed prenatally. Bone tumour incidence was increased by exposure to Pu in all age groups. The younger rats were less sensitive on an ...
1979-03-30
Radiation exposure to anesthesiologist and nurse in the orthopedic room
International Nuclear Information System (INIS)
We report the radiation exposure dose received by the anesthesiologist and nurse in the orthopaedic operating room, when a fluoroscopic image intensifier is in use. This study was done in 12 femoral neck fracture operations performed from January to May 1995. Radiation was monitored with the MYDOSE MINIX PDM 107 made by Aloka Co. which were attached in front and behind the nurse's lead apron, in front of the lead apron of the anesthesiologist. The average imaging time was 9.78 min. The average radiation dose in front of the anesthesiologist is lead apron was 2.08#mu#SV, and in front and behind the nurse's lead apron were 5.67#mu#SV, 0.08#mu#SV respectively. This study and review of the literature indicate that the operating room anesthesiologist and nurse receive a lower exposure than the orthopaedist. We can disregard the problem of radiation exposure to the ...
Environmental impact assessment around TRIGA research reactor
International Nuclear Information System (INIS)
Population distribution, atmospheric change, X/Q, characteristics of terrestrial ecosystem around Seoul site were surveyed. Environmental radiation and radioactivities such as gross#alpha#, gross#beta#, Cs-137, Sr-90 and H-3 of various environmental samples were analyzed. The values of environmental radiation dose tended to increase gradually in the light of the recent five years' results of environmental radiation monitoring around the nuclear power plants from 1980 to 1984, however, the changes were not significant. In addition, continuous assessment of environmental radiation monitoring on the roofs of main building and life science building at KAERI showed that the environmental radiation dose tended to increase a little during the night time. Judging from the above results, it is concluded that environmental contamination level by ...
1985-04-01
Effective radiation therapy on two cases of primary Ewing's sarcoma of the rib
International Nuclear Information System (INIS)
Two cases of primary Ewing's sarcoma of the rib are reported, in which radiation therapy was quite effective. Case 1 was an 18-year-old female who had had an operation and radiation therapy for Ewing's sarcoma of the left 7th rib. She was referred to our hospital after a recurrent tumor was found. Radiation therapy (tumor dose 46.2 Gy) and chemotherapy were given. The tumor disappeared and there has been no relapse for 1 year and 3 months after the treatment. Case 2 was a 2-year-old-infant. Radiation therapy (tumor dose 74 Gy) was given for primary Ewing's sarcoma of the left 6th rib. The tumor became small and was successfully removed at operation. There has been no relapse or distant metastasis for 8 months following the operation. We emphasize the importance of multidisciplinary treatment in case 1 and the usefulness of preoperative radiotherapy in case 2. ...
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was ...
2007-03-15
Experimental chemo- and radio-therapy on human cholangiocarcinoma transplanted to nude mice
International Nuclear Information System (INIS)
A human cholangiocarcinoma, Ch-1, serially transplanted to nude mice was used for experimental chemotherapy, radiotherapy, and conbination chemoradiotherapy. In the group of chemotherapy with single drug, Mitomycin C (MMC) revealed greater effectiveness than Adriamycin in terms of tumor regression, histological findings, and minor side effects. MMC and radiotherapy by Linac X-ray showed exponential linear dose response curve against tumor weight. Their effects were equivalent at doses of MMC 1 mg/kg and radiation 1,000 rads/mouse in the changes of tumor weight and of histological findings which were similar to each other. Combination chemoradiotherapy showed the synergistic action when the radiation (500 rads/mouse) was performed before MMC (0.5 mg/kg) administration, whereas only the additive effect was observed when the sequence was reversed. The cell kinetic analysis was performed by the impulse ...
Energy Technology Data Exchange (ETDEWEB)
The aetiology of childhood leukaemia remains generally unknown, although exposure to moderate and high levels of ionising radiation, such as was experienced during the atomic bombings of Japan or from radiotherapy, is an established cause. Risk models based primarily upon studies of the Japanese A-bomb survivors imply that low-level exposure to ionising radiation, including to ubiquitous natural background radiation, also raises the risk of childhood leukaemia. In a recent paper (Wakeford et al 2009 Leukaemia 23 770-6) we estimated the proportion of childhood leukaemia incidence in Great Britain attributable to natural background radiation to be about 20%. In this paper we employ the two sets of published leukaemia risk models used previously, but use recently published revised estimates of natural background radiation doses received by the red bone marrow of ...
2009-12-01
Energy Technology Data Exchange (ETDEWEB)
(001) CZ silicon wafers were implanted with arsenic (As{sup +}) at energies of 10--50 keV to doses of 2 {times} 10{sup 14} to 5 {times} 10{sup 15}/cm{sup 2}. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of ...
1997-11-01
International Nuclear Information System (INIS)
(001) CZ silicon wafers were implanted with arsenic (As"+) at energies of 10--50 keV to doses of 2 x 10"1"4 to 5 x 10"1"5/cm"2. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface ...
1996-12-02
Is uniform target dose possible in IMRT plans in the head and neck?
International Nuclear Information System (INIS)
Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...
2002-04-01
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
International Nuclear Information System (INIS)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the ...
2007-06-01
International Nuclear Information System (INIS)
Background and purpose: the recent RTOG guidelines for future clinical developments in gynecologic malignancies included the investigation of dose escalation in the paraaortic (PO) region which is, however, very difficult to target due to the presence of critical organs such as kidneys, liver, spinal cord, and digestive structures. The aim of this study was to investigate intensity-modulated radiotherapy's (IMRT) possibilities of either increasing, in a safe way, the dose to 50-60 Gy in case of macroscopic disease or decreasing the dose to organs at risk (OR) when treatment is given in an adjuvant setting. Material and methods: the dosimetric charts of 14 patients irradiated to the PO region at the department of radiation oncology, university hospital of Liege, Belgium, in 2000 were analyzed in order to compare six-field conformal external-beam radio-therapy (CEBR) and five-beam IMRT approaches. Both ...
2005-03-01
Effective dose estimation in whole-body multislice CT in paediatric trauma patients
Energy Technology Data Exchange (ETDEWEB)
The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean ...
2009-03-15
Radiation hardening of CMOS-based circuitry in SMART transmitters
International Nuclear Information System (INIS)
Process control transmitters that incorporate digital signal processing could be used advantageously in nuclear power plants; however, because such transmitters are too sensitive to radiation, they are not used. The Electric Power Research Institute sponsored work at Sandia National Laboratories under EPRI contract RP2614-58 to determine why SMART transmitters fail when exposed to radiation and to design and demonstrate SMART transmitter circuits that could tolerate radiation. The term ''SMART'' denotes transmitters that contain digital logic. Tests showed that transmitter failure was caused by failure of the complementary metal oxide semiconductors (CMOS)-integrated circuits which are used extensively in commercial transmitters. Radiation-hardened replacements were not available for the radiation-sensitive CMOS circuits. A conceptual design showed that a ...
Radiation effects on MOS devices and radiation-hard CMOS technologies
International Nuclear Information System (INIS)
Total-dose irradiation seriously damages MOS devices and their circuit performance. Threshold voltage shifts, transconductance degradation and increase in off-state leakage current are generally observed for irradiated devices. These instabilities are essentially due to positive and/or negative charge trapping in SiO_2 and interface trap generation at the SiO_2/Si interface. Radiation hardening of CMOS VLSIs is to eliminate these trapping effects, and for this purpose, special considerations for fabrication processes and layout design are necessary. In this paper, basic mechanisms for radiation-induced charge trapping and related effects on MOS devices are reviewed. Also discussed are radiation-hardening technologies from both fabrication-process and layout-design viewpoints. Using these technologies, 1 #mu#m radiation-hard CMOS gate arrays have been successfully developed. ...
Modulating factors in the expression of radiation-induced oncogenic transformation
Energy Technology Data Exchange (ETDEWEB)
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...
1990-08-01
Modulating factors in the expression of radiation-induced oncogenic transformation
International Nuclear Information System (INIS)
Many assays for oncogenic transformation have been developed ranging from those in established rodent cell lines where morphological alteration is scored, to those in human cells growing in nude mice where tumor invasiveness is scored. In general, systems that are most quantitaive are also the least relevant in terms of human carcinogenesis and human risk estimation. The development of cell culture systems has made it possible to assess at the cellular level the oncogenic potential of a variety of chemical, physical and viral agents. Cell culture systems afford the opportunity to identify factors and conditions that may prevent or enhance cellular transformation by radiation and chemicals. Permissive and protective factors in radiation-induced transformation include thyroid hormone and the tumor promoter TPA that increase the transformation incidence for a given dose of radiation, and retinoids, ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the ...
2006-02-24
International Nuclear Information System (INIS)
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...
2009-03-01
Detection of Free-Living Amoebae in Some Water Sources and its Control by Ultraviolet- Radiation
International Nuclear Information System (INIS)
Among the numerous free-living amoebae (FLA) of soil and water habitats, certain species belonging to two genera Acanthamoeba and Naegleria are facultative parasites of man.They cause disease called primary amoebic meningoencephalitis where history of contact with water was recorded in most of the cases especially with Naegleria species. The present work aimed to search for presence of free-living amoebae in the water and trials for its control by Ultraviolet-radiation (UV-radiation). Samples from different water sources were examined for the presence of free-living amoebae. These samples were cultured on non-nutrient agar streaked with bacteria. Amoebae were detected and identified by means of their morphological characters. Twelve positive cases of one hundred and twenty examined samples could be detected. The positive samples were exposed to different doses of UV-radiation for different times.
The effects of cosmic radiation on implantable medical devices
Energy Technology Data Exchange (ETDEWEB)
Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 G{gamma}) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset ...
1996-12-31
Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)
Energy Technology Data Exchange (ETDEWEB)
The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18{sup 0}C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4{sup 0}C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. Irradiation ...
1990-01-01
Ultrastructural effect of gamma radiation on grass shrimps (Penaeus monodon Fabricius)
International Nuclear Information System (INIS)
The effect of ionizing radiation (2, 5, and 10 KGy of gamma rays) on muscle ultrastructure of grass shrimps (Penaeus monodon Fabricius) tails at ambient or frozen (-18"0C) temperature was investigated by transmission electron microscopy (TEM). No significant change was found in muscle ultrastructure of shrimp meat irradiated at doses of 2 or 5 KGy and then stored at 4"0C for 0 and 8 days. However, in shrimps which were irradiated at ambient temperature at a dose of 10 KGy, the margin of A-band of the myofibrils in longitudinal sections exhibited an irregular zig-zag pattern. In cross section some myosin filaments in the A-band regions were missing. A possible interpretation of these results would be that 10 KGy gamma irradiation dose at ambient temperature depolymerized myosin in the A-band from the tail of thick filament. Actin damage was also observed in some cross sections. Irradiation damage of ...
Thermal expansion of gamma irradiated nylon 66 from 10 K to 340 K
Energy Technology Data Exchange (ETDEWEB)
Samples of nylon 66 rods were irradiated using a cobalt-60 gamma ray source at a dose rate of 0.25 Mrad h[sup -1] in air at room temperature to a maximum dose of 500 Mrad. The linear coefficient of thermal expansion ([alpha]) was measured using a three-terminal capacitance technique reported previously. The variation of [alpha] with temperature between 10 K and 340 K was investigated for an unirradiated sample and two samples irradiated to 300 Mrad and 500 Mrad. In the range 10K to 160K, [alpha] is almost invariant with radiation dose and there is little difference between the values for the unirradiated and the 300 Mrad irradiated samples above 160 K. The sample irradiated to 500 Mrad does show a 6% increase in [alpha] over the other samples in the higher temperature range. All samples show an increase overall in the value of [alpha] with temperature. The melting point of each sample was also ...
1994-08-15
Studies on radiation induced changes in bovine hemoglobin type A
International Nuclear Information System (INIS)
In this paper the structural and functional changes of gamma irradiated bovine hemoglobin are presented. Aqueous solutions/1%/of HbO_2 were irradiated in air with doses ranging from 1 to 4 Mrad. Isoelectric focusing indicated change of the charge of irradiated hemoglobin. The isoelectric point of hemoglobin was displaced towards more acid values with increasing doses, up from 1 Mrad. Fingerprint analysis and peptide column chromatography of irradiated hemoglobin demonstrated disturbances increasing with the dose. These changes were confirmed by amino acid analysis which showed that Cys, Met, Trp, His, Pro and Tyr residues were destroyed or modified following irradiation. At doses exceeding 1 Mrad the irradiated solutions of hemoglobin showed a decrease of heme-heme interaction and an increase of affinity for oxygen. Differences observed in oxygen-dissociation curves seem to be correlated with the ...
Energy Technology Data Exchange (ETDEWEB)
The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical ...
1982-04-01
International Nuclear Information System (INIS)
The preparation of wood-plastic combinations (WPC) using combined methods for curing intermediate products and final products is described. In the first step, impregnated wood was irradiated using doses of 1 to 10 kGy in the presence of chemical initiators of polymerization. Thereafter, curing of this partly cured impregnating mixture was accomplished in the wood at elevated temperatures with the aid of chemical initiators of polymerization. Impregnation mixtures based on unsaturated polyester resins and methyl methacrylate, and the wood species European Beech (Fagus silvatica) and Black Alder (Alnus glutinosa) were used. The results indicate that this method of preparing WPC allows substantially lower radiation doses to be used, i.e., doses in the range of 1 to 2.5 kGy. These doses gelatinate the impregnation mixture in the wood so that the subsequent curing by chemical ...
1982-01-01
Optimisation of imaging technique used in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. ...
2006-09-15
Optimisation of imaging technique used in direct digital radiography
International Nuclear Information System (INIS)
The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. ...
2006-09-01
Induction of apoptosis in chicken bursal B cells
Energy Technology Data Exchange (ETDEWEB)
Cell death in general can be a physiological process of cell number regulation in tissue, or it can be the result of exo or endogenous injuries, such a low-dose of radiation. Chicken B cell population in the bursa of Fabricius are very susceptible to PCD. Our present studies concern the development of radiation damage of chicken defence mechanisms. In 6 experiments pathogen free chicken were irradiated by gamma rays with the total doses of 0.25, 0.5, 1.0, 2.0 and 4.0 Gy. The induction of apoptosis was checked by Flow-cyto-meter 12 h after irradiation in bursa cell suspension. There is some increase in the number of induced apoptotic cells 12 h after irradiation at the dose 0.5-.4.0 Gy. There were no significant changes in the proportion of proliferating lymphocytes (G2 M), but cellularity decreased significantly at dose 2.0 and 4.0 Gy/12 h after irradiation. ...
1997-03-01
Energy Technology Data Exchange (ETDEWEB)
The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate ...
1992-07-01
Experience in using Fuji computed radiography (FCR), 1
Energy Technology Data Exchange (ETDEWEB)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR ...
1984-12-01
Experience in using Fuji computed radiography (FCR), 1
International Nuclear Information System (INIS)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR ...
1984-01-01
Effects of gamma and electron beam irradiation on the properties of calendered cord fabrics
Energy Technology Data Exchange (ETDEWEB)
The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that PET calendered fabric has higher resistance to ionizing radiation. Ny 6 and Ny 66 ...
2010-03-15
Computed radiography for major airway in pediatrics
International Nuclear Information System (INIS)
This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate ...
1986-01-01
Theoretical considerations for SRAM total-dose hardening
International Nuclear Information System (INIS)
The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented.
International Nuclear Information System (INIS)
A mixture of aminoacids was irradiated by a scattered proton beam, its energy varying from 4 to 6.6 MeV, by doses up to 5 x 10"1"1 proton/cm"2 for studying the potentiality of abiogenic synthesis of biologically important compounds in space. It was ascertained that increase in the radiation dose and reduction of proton energy involve increase in effectiveness both of destruction of the initial aminoacid (tryptophan, tyrosine, glycine) and synthesis of the relevant dipeptide. Essential influence of mineral substrate on abiogenic synthesis of natural nucleotides under the action of diverse energy sources was pointed out
2004-04-01
Mathematical child phantom for the calculation of dose to the organs at risk
Energy Technology Data Exchange (ETDEWEB)
In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.
1988-05-01
Gastrointestinal radiography using Fuji computed radiography (FCR)
International Nuclear Information System (INIS)
Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).
1985-01-01
International Nuclear Information System (INIS)
The utilization of the Ellis-formula for the determination of the tolerance of normal connective tissue is described. Beyond this, the formula is adapted to so-called critical organs. The individual suppositions implicated by the Ellis-formula are commented. Because of the verifyable congruency of the Ellis-formula with data obtained in clinical practice also by other authors, this conception is presented for the provisional determination of the limits of tolerance of normal tissue together with a computerized programme elaborated for use in different therapeutic techniques. (orig.).
1976-01-01
UV inactivation: Combined effects of UV radiation and xenobiotics in two strains of Saccharomyces
International Nuclear Information System (INIS)
The effects of eight chemicals on the inactivation rate of ultraviolet radiation on the colony building capabilities of two strains of Saccharomyces cervisae - a wild type strain and a mutant deficient in excision repair - were studied. The insecticide methoxychlor, the herbicide 2,4-dichlorophenoxyacetic acid, the fungicide pentachlorophenol and its metabolite tetrachlorohydroquinone, as well as the chemicals acrylonitrile and 2,3-dichloro-1-propene have no significant impact on the effects of UV radiation in Saccharomyces cerevisae. Depending on the concentration, trichloroethylene increases the sensitivity to UV radiation. The herbicide paraquat provides efficient protection against UV radiation at concentrations where a toxic effect cannot be observed even without UV. The results were rather similar for both strains. (orig.).
Specific features of radiation damage in titanium alpha-alloys
International Nuclear Information System (INIS)
Titanium base 'alpha'-alloys (Pt-7M, RK-20 and Ti-5Al-2Zr-1.5V) are considered for their behaviour under neutron irradiation. The role of alloying elements in radiation hardening is discussed depending of neutron fluence and irradiation temperature. For PK-20 alloy three stages of change in mechanical properties are revealed which are following: incubation period and weak hardening, intense radiation hardening, radiation hardening attenuation. Irradiation temperature rise results in an increase of incubation period and threshold neutron fluence. A special attention is paid to hydrogen absorption in #alpha#-titanium alloys under irradiation. It is concluded that titanium base 'alpha'-alloys are serviceable as structural materials in nuclear plants with allowance made for peculiar features of their radiation behaviour. 4 refs.; 7 figs.; 1 tab.
Behaviour Features of the Radiative Losses of the Torsatron U-3M Plasma
International Nuclear Information System (INIS)
The total bolometrically measured plasma radiation losses on the RF heating power were found. The results of measurements demonstrate a nonmonotonic dependence of radiation losses on RF power. Namely, at low RF power levels (80...170 kW) the total radiation losses raised with increasing the RF power. However, the total radiation losses decreased sharply when RF power exceeded 200 kW (down to ?20 kW at 240 kW of RF power). Simultaneously, the intensity of impurity lines fell down significantly, whereas the average electron temperature (found from ECE measurement) increased. The authors consider that screening properties of periphery plasma give reasons for above experimental facts.
2006-01-01
International Nuclear Information System (INIS)
Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with ...
1997-05-01
Effects of low-level radiation upon the hematopoietic steam cell: implications for leukemogenesis
Energy Technology Data Exchange (ETDEWEB)
These studies have addressed firstly the effect of single small doses of x-ray upon murine hematopoietic stem cells to obtain a better estimate of the D/sub q/. It is small, of the order of 20 rads. Secondly, a dose fractionation schedule tht does not kill or perturb the kinetics of hemopoietic cell proliferation was sought in order to investigate the leukemogenic potential of low level radiation upon an unperturbed hemopoietic system. The studies reported herein show tht 1.25 rads every other day decrease the CFU-S content of bone marrow by the time 40 rads are accumulated. Studies on the effect of 0.5, 1.0, 2.0, and 3.0 rads 3 times per week are under way. Two rads 3 times per week produced a modest decrease in CFU-S content of bone marrow after an accumulation of 68 rads. With 3.0 rads 3 times per week an accumulation of 102 rads produces a significant decrease in CFU-S content of bone marrow. Dose ...
1983-01-01
International Nuclear Information System (INIS)
7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x ...
1986-01-01
International Nuclear Information System (INIS)
The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...
1983-06-01
Energy Technology Data Exchange (ETDEWEB)
Rice plants at different seed-developing stages were exposed to HTO vapor in an exposure box for 1 h during daytime and nighttime to investigate the levels of tissue free water {sup 3}H (TFWT) and organically bound {sup 3}H (OBT) in different plant parts. In the daytime experiment, TFWT concentrations in leaves at the end of exposure (h{sub 0}) were around 100% of the 1 hour mean HTO concentrations in air moisture whereas in the nighttime experiment, they were as low as 30{approx}40% of the air concentration. TFWT concentrations in both experiments decreased very rapidly in the beginning but much more slowly later and those at harvest were hundreds to hundred thousands times lower than those at h{sub 0}. OBT concentrations varied with time in different manners depending on plant parts and exposure times and differed between at h{sub 0} and at harvest by factors of less than 10 on the whole. Even during nighttime exposures, OBT was produced at about a third the rate ...
2003-03-15
Search for the active components and studies on the mechanism of the hematopoiesis improvement foods
Energy Technology Data Exchange (ETDEWEB)
In this experiments, we established long-termed culture methods of bone marrow stromal cells for proliferation and differentiation of stem cells. And we selected some extracts which support maximal proliferation of stromal cells with this method. We conformed the synergic effects of herval mixture extracts for stromal cell growth. The proliferation of stromal cells was increased rather by the addition of mixture extracts than by addition of single strain extract. In the previous and cooperative experiments, we selected complex extracts which increased the number of nonadherent mononuclear cells. Different cytokine expression patterns were observed stromal cells cultured in the presence or absence of mixture extracts which support differentiation of nonadherent cells. Stimulation of macrophage cell line with herval extracts with the treatments of recombinant interferon-{gamma} resulted in increased nitric oxide synthesis in a dose-dependent manners. In addition, ...
1999-04-01
Radon emanation and soil moisture effects on airborne gamma-ray measurements
Energy Technology Data Exchange (ETDEWEB)
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay soils. The theoretical and experimental ...
1997-09-01
Radon emanation and soil moisture effects on airborne gamma-ray measurements
International Nuclear Information System (INIS)
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay soils. The theoretical and experimental ...
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
2007-11-15
International Nuclear Information System (INIS)
Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests that small tumors may be difficult to detect againist such an ...
Energy Technology Data Exchange (ETDEWEB)
To obtain Pinus wood-plastic composites, wood samples were impregnated with methyl methacrylate and polymerized by the use of gamma rays from a /sup 60/Co at different dose exposure and total dose. The best percentage of polymerization was obtained with the exposure of 2.0 MR of gamma radiation. It was found that the impregnation and polymerization, determined by the density values along the samples were uniform. The density became 2.6 times higher in relation to the control samples. The storage of the impregnated wood samples showed losses of the monomer, even when wrapped with aluminum or polyethylene film. It is recommended that the wood samples should be irradiated soon after impregnation.
1984-12-01
UK regulations for NORM [naturally occurring radioactive material
International Nuclear Information System (INIS)
The primary UK legislation relating to the use of radioactive materials are the Radioactive Substances Act 1993 (RSA, 1993) and the Ionising Radiations Regulations 1999 (IRR, 1999). These implement the European Union's Basic Safety Standards Directive (EUBSS) (EC, 1996). The Radioactive Substances Act 1993 (RSA93) regulates the accumulation, storage and disposal of radioactive waste, principally to control potential doses to members of the public. The Ionising Radiations Regulations 1999 (IRR, 1999) deal primarily with regulating the doses that people receive at work. Both of these pieces of legislation apply to the use of materials containing naturally occurring radionuclides. Historically UK regulations relating to radioactive materials have covered both artificial and natural radionuclides
2002-09-23
Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level
Energy Technology Data Exchange (ETDEWEB)
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
2003-07-01
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by Deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on Tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-3 and 4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2006-11-13
International Nuclear Information System (INIS)
Tarapur Atomic Power Station unit-4 is first 540 MWe pressurized heavy water reactor. Heavy water is used as the coolant and moderator. With reactor operation tritium is formed by absorption of neutron by deuterium atoms. Experience in the 220 MWe indicates that tritium is main contributor to the internal dose of radiation workers. Study on tritium build up in Primary Heat Transport (PHT) and Moderator (MOD) system was carried out at the initial stage of the operation of the unit-4. This paper brings out tritium activity buildup in the PHT and MOD systems and its comparison with 220 MWe reactors. This paper helps in estimation of the internal dose contribution to the radiation workers at TAPS 3 and 4. (author)
2005-11-23
Somatic effects in nuclear medicine and radiology
International Nuclear Information System (INIS)
Probable risks for the occurrence of somatic effects due to diagnostic radiology and nuclear medicine are summarised. The biological background of radiation carcinogenesis and epidemiological results are discussed. At the Leiden University Medical Centre the average effective dose per examination due to diagnostic radiology and nuclear medicine amount to 0.95 and 4.4 mSv, respectively. These values correspond well with the average values of 0.82 and 3.0 mSv reported for The Netherlands as a whole. Since radiological examinations are performed at a much larger frequency than nuclear medicine the relative collective dose for the first type of examinations is higher than the latter. Risk for occurency of malignancies are at least one order of magnitude lower than the hypothetical risk due to the background radiation typical of The Netherlands.
1999-01-01
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...
2007-01-01
Effect of gamma rays on grafting parameters and liquid retention property of cassava starch-g-PAN
International Nuclear Information System (INIS)
Radiation modification on liquid retention properties of native cassava starch, gelatinized at 85"0C, by graft copolymerization with acrylonitrile was carried out by mutual irradiation to #gamma#-rays. A thin aluminium foil was used to cover the inner wall of the reaction vessel so that the extent of homo polymer could be reduced to be less than 1.6% with a distilled water retention value of 665 g/g of the dry weight of the saponified grafted product. Confirmations of graft copolymerization and saponification reactions were made by the infrared spectrophotometric technique. The combined effect of radiation parameters in terms of an irradiation time and a dose rate to the same total dose on the extent of grafting reaction expressed in terms of grafting parameters which directly influenced liquid retention values was evaluated in conjunction with statistical analysis.
1992-10-20
International Nuclear Information System (INIS)
The effect of five doses of gamma radiation: 10, 100, 500, 1000 and 5000 Gy on chlorophylls content, net photosynthesis and respiration of chlorella pyrenoidosa has been studied. A decrease in chlorophylls levels is produced after irradiation at 500, 1000 and 5000 Gy, being, at first 'b' chlorophyll affected to a greater extent than 'a' chlorophyll. Net photosynthesis and respiration decline throughout the time of the observations after irradiation, this depressing effect being much more remarkable for the first one. Net photosynthesis inhibition levels of about 30% have got only five hours post irradiation at a dose of 5000 Gy. (author).
British Library Electronic Table of Contents (United Kingdom)
Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...
2009-01-01
Channeling studies of radiation damage in metal-silicides
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.
1978-01-01
Channeling studies of radiation damage in metal-silicides
International Nuclear Information System (INIS)
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.
Radiative transfer in a solar absorbing particle laden flow
A possible receiver configuration is a cavity in which a falling sheet of solid particles is directly irradiated by the concentrated solar flux passing through the aperture. Regardless of the particular geometry, the radiative transfer within the falling particle curtain must be studied in order to determine the net radiative heating rate for the particles. A discrete ordinate radiative transfer model has been developed to predict the radiative coupling within the falling particle curtain. The model determines how much energy is absorbed by the particles, how much is transmitted to the rear wall of the receiver, and determines the effects of particle scattering and thermal emission on the net radiation absorbed by the particles. The model accounts for the directional nature of the radiation field, particle scattering, and the wavelength ...
1985-11-01
The efficacy of low-dose radiation therapy and surgical resection for Ewing's sarcoma
International Nuclear Information System (INIS)
Purpose: To evaluate the effect of low-dose radiation therapy and surgery on local control in patients with Ewing's Sarcoma. Materials and Methods: Between 1979 and 1995 24 patients (ages 4-47) with Ewing's sarcoma were treated with combined modality therapy that included multi agent chemotherapy, surgical resection, and radiation therapy. Twelve patients had metastatic disease at the time of presentation (pleura = 3, lung = 5, bone 4). Tumor location was central in 16 and peripheral in 8. Multi agent chemotherapy consisted of vincristine/actinomycin D/cyclophosphamide/doxorubicin in 19. The same agents with the addition of ifosfamide and etoposide were given in 5. The extent of resection was considered to be radical in 14 and of the 16 patients who received preoperative chemotherapy, 5 were found to have a pathologic complete response. All patients with lung metastases at diagnosis received whole-lung irradiation to 1400 ...
1996-09-01
Second harmonic generation of copper-vapor pulsed laser radiation
Energy Technology Data Exchange (ETDEWEB)
An experimental study of second harmonic generation in a copper-vapor pulsed laser with an ADP crystal is presented. The ratio of the conversion into the second harmonic is found to depend on the average power of the exciting radiation. The maximum conversion ratio was 8.5%. Thermal self-defocusing is the main obstacle to obtaining high average powers at the double frequency.
1980-08-01
Radiation treatment of some poultry products
International Nuclear Information System (INIS)
Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.
1988-09-26
Dosimetric characteristics of backscattered electrons in lead
Energy Technology Data Exchange (ETDEWEB)
In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) wasdefined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence of the EBF on the beam energy incident on the scatterer has been studied for different nominal beam energies incident at the phantom's surface. The results show a trend of increase of EBF ...
2000-07-01
Radiation-related damage to the developing human brain
International Nuclear Information System (INIS)
The authors summarize the significant dose-related effects on brain development which have emerged largely within the last six years of study of prenatally exposed A-bomb survivors. The results are described primarily in terms of the DS86 estimates and differences between these and the older T65DR dose estimates are discussed. The severe mental retardation sample was based on 1598 individuals taken from the PE-86 sample, and the intelligence test scores considered from the same sample involved 1673 children. The authors also discuss some of the recent neurobiological developments that appear relevant to an understanding of the biological bases of dose-related events observed, and suggest future research that may contribute either to further delineation of exposure consequences or to the explanation of the cellular and molecular origins of observed effects. (UK).
Prevention of death from ingested ruthenium-106 by colectomy
International Nuclear Information System (INIS)
Two dogs were given 3.0 mCi/kg body weight of "1"0"6Ru-"1"0"6Rh and two were given 4.0 mCi/kg. At 5 days after treatment, one dog from each dose level was colectomized. The dog given the larger dose but not surgically treated was killed in extremis due to acute lower bowel injury at 18 days. The other dog, given 3.0 mCi/kg but not surgically treated, was killed in a moribund condition at 145 days after dosing. The rectum had perforated. The colectomized dogs recovered from intestinal injury and showed no radiation damage at the termination of the study.
1977-05-01
Measurement of induced radioactivity in materials found around a neutron generator
The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)
1974-01-01
Ewing's sarcoma of the vertebral column
International Nuclear Information System (INIS)
Twenty-two patients with vertebral primaries were registered in the Intergroup Ewing's Sarcoma Study between 1973 and 1977. The radiation doses to the primary tumors ranged between 3800 and 6200 rad. All patients received intensive combination chemotherapy. After a followup ranging between 14 and 62 months, 14 patients remained disease-free. All patients with primary tumor of the cervical and dorsal spine remained disease-free. Of eight patients with lesions in the distal spine, (sacrococcygeal region) six developed recurrence, in three a local recurrence was observed despite doses of 6000 rad or higher. Doses of 5000 rad or less (in addition to combination chemotherapy as used in the Intergroup Ewing's Study) appear adequate in controlling the primary tumors of the proximal segments of the spinal column.
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
Energy Technology Data Exchange (ETDEWEB)
Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.
1998-01-01
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...
2009-01-01
Adaptive Management of Liver Cancer Radiotherapy
British Library Electronic Table of Contents (United Kingdom)
Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...
2010-01-01
The wavelength dependence of ultraviolet enhanced reactivation in a mammalian cell-virus system
International Nuclear Information System (INIS)
The effect of UV radiation in the wavelength region 230 nm to 302 nm on the ability of an irradiated mammalian cell to reactivate UV-irradiated mammalian virus was tested. An action spectrum for radiation enhanced reactivation (RER) is presented. The shape of the action spectrum points to a combined nucleic acid-protein target for UV radiation effects on this cellular parameter. An analysis of the results of others involving the biochemical and photobiological events involved in RER does not allow us to distinguish which macromolecule is the major contributor to this effect. Studies involving an analogous phenomenon in bacteris (Weigle reactivation) imply that RER and WR amy involve similar mechanisms. (author).
The effect of temperature on the radiative performance of Ho-YAG thin film selective emitters
Energy Technology Data Exchange (ETDEWEB)
The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.
1995-01-01
International Nuclear Information System (INIS)
The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.
Energy Technology Data Exchange (ETDEWEB)
The report published in 2003 by the European committee on the risk of irradiation (C.E.R.I.) criticizes a part of the ICRP recommendations relative to the internal contaminations.Consequently, I.R.S.N. wishes to supply its own analysis. The present report points the questions linked to the internal contamination and to the difficulties inherent to the risk incurred after chronic exposure.Consequently it does not treat all the problems of the workers and populations radiation protection. (N.C.)
2005-07-01
International Nuclear Information System (INIS)
Dose measurements were performed in several body regions of patients suffering from inflammatory degenerative diseases (humeral epicondylitis, humeroscapular periarthritis, gonarthrosis, axillary hidradenitis, rheumatoid arthritis, coxarthrosis, parotitis). The problem of the radiation induction of neoplasms is predominant concerning somatic as well as genetic risk, discussed by example of the most frequently occurring organ cancer. Compared to the rate of breast cancer in the highly developed industrial states (5,000 to 6,000 cancers/100,000 women) the 'radiation induction' calculated according to a mathematical model of ICRP 26 (1.25 cases of death for breast cancers/100,000 women following for example irradiation of epicondylitis) is behind several powers of ten and not demonstrable. The genetic radiation exposure is also low. Derived from the measurements it is wrong to give up reliable and approved ...
1983-01-01
Is energy imparted a good measure of the radiation risk associated with CT examinations
International Nuclear Information System (INIS)
The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...
Energy Technology Data Exchange (ETDEWEB)
In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co{sup 60}). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to ...
2001-04-01
Bevacizumab as a treatment option for radiation-induced cerebral necrosis
International Nuclear Information System (INIS)
Radiation necrosis of normal CNS tissue represents one of the main risk factors of brain irradiation, occurring more frequently and earlier at higher total doses and higher doses per fraction. At present, it is believed that the necrosis results due to increasing capillary permeability caused by cytokine release leading to extracellular edema. This process is sustained by endothelial dysfunction, tissue hypoxia, and subsequent necrosis. Consequently, blocking the vascular endothelial growth factor (VEGF) at an early stage could be an option to reduce the development of radiation necrosis by decreasing the vascular permeability. This might help to reverse the pathological mechanisms, improve the symptoms and prevent further progression. A patient with radiation-induced necrosis was treated with an anti-VEGF antibody (bevacizumab), in whom neurologic signs and symptoms improved in ...
2011-02-01
Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant
International Nuclear Information System (INIS)
This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, ...
1987-01-01
Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, ...
1987-09-01
International Nuclear Information System (INIS)
The release of any potential radioactive pollutant to the environment during routine operation of a Nuclear Power Plant should be the subject of appropriate controls and assessments. It is impossible to monitor directly the dose contribution of normal releases because the environmental radioactivity levels are very small but source monitoring provides a means of assessing the radiation exposure of population groups, critical groups and individual members of the public. Derived emissions limits ( DELs ) are used to quantify the relationship between releases of radioactivity and doses to public - critical groups. CNE Cernavoda DELs are based on a pathway analysis conducted for Cernavoda site specific conditions and they were computed using a compartment transfer model. Annual air and water emissions for the most significant radionuclides between 1997 and 2008 are presented in terms of doses and can be ...
2009-10-12
INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS
International Nuclear Information System (INIS)
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic ...
2010-07-11
Dose assessment and behavior of tritium in environmental samples around Wolsong nuclear power plant.
For the estimation of the dispersion trend of tritium discharged from the Wolsung nuclear power plant, the present level of tritium in environmental samples in the vicinity of the Wolsong site has been studied. On the basis of tritium concentrations in environmental samples, the effective dose due to tritium has been estimated for an individual and population within a 16 km radius from the Wolsong site. The annual effective dose of tritium to an inhabitant around the Wolsong site ranged from 0.15 microSv y-1 to 1.3 microSv y-1. The dose level was negligible and much lower than some applicable standards, i.e. the limit on exposure from nuclear fuel cycle to the general public as recommended by ICRP (1 mSv y-1) or US EPA's limit (0.25 mSv y-1). The collective dose to the total population within a 16 km radius from the site, 1.2 x 10(-2) man.Sv y-1 was much lower than 1 man.Sv y-1, an applicable criterion ...
1999-04-01
Departure from ICRP-60 in Canadian radiation protection regulations
International Nuclear Information System (INIS)
The Atomic Energy Control Board (AECB), Canada's nuclear regulatory authority, is preparing new regulations based on ICRP-60. The proposed regulations have some features which are different from ICRP-60, e.g., the limit for pregnant workers was set at a higher level than that proposed in ICRP-60. The AECB, through its consultative process, received many responses from female staff in nuclear medicine. The concern was that it would be very difficult to prove compliance with such low doses, particularly for internal doses. There was an additional concern that hospital administrators would respond to the reduction of the current pregnant worker limit from 10 mSv to the ICRP-60 recommended value of 2 mSv by discriminating against hiring women. A new proposal for the dose limit for pregnant workers has been made which will limit the dose to the mother by means of a combining formula that will take both ...
A water calorimeter for high energy x-rays and electrons
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV ...
2000-01-01
Effects of epidermal growth factor on bone formation and resorption in vivo
Energy Technology Data Exchange (ETDEWEB)
The effects of mouse epidermal growth factor (EGF) on bone formation and resorption were examined in male mice. EGF administration (2-200 ng.g-1.day-1 ip for 7 days) induced a dose-dependent rise in plasma EGF levels that remained within physiological range. Histomorphometric analysis of caudal vertebrae showed that EGF (20 and 200 ng.g-1.day-1) reduced the endosteal matrix and mineral appositional rates after 5 days of treatment as measured by double (3H)proline labeling and double tetracycline labeling, respectively. This effect was transitory and was not observed after 7 days of EGF administration. EGF administered for 7 days induced a dose-dependent increase in the periosteal osteoblastic and tetracycline double-labeled surfaces. At high dosage (200 ng.g-1.day-1) EGF administration increased the osteoclastic surface and the number of acid phosphatase-stained osteoclasts, although plasma calcium remained normal. The results show that EGF ...
1990-02-01
Energy Technology Data Exchange (ETDEWEB)
Potential maximum radiation dose rates over a 1,000-year time horizon were calculated for exposure to the decontaminated concrete removed from the 183-H Solar Evaporation Basins at the Hanford Site, Richland, Washington. The RESRAD computer code, Version 5.62, which implements the methodology described in the US Department of Energy`s manual for developing residual radioactive material guidelines, was used in this evaluation. Currently, the concrete is not being used. Four potential exposure scenarios were developed for the land area where the decontaminated concrete will be stored. In Scenario A industrial use of the land is assumed; in Scenario B recreational use of the land is assumed; in Scenario C residential use of the land is assumed; and in Scenario D (a plausible but unlikely land-use scenario), the presence of a subsistence farmer in the immediate vicinity of the land is assumed. For Scenarios A and B, water used for drinking is ...
1997-01-01
Progress and challenges in the discovery of macrofilaricidal drugs
British Library Electronic Table of Contents (United Kingdom)
Control of human filarial infections currently depends on chemotherapeutic strategies predominantly directed at microfilariae. Doxycycline therapy in an extended daily dose regimen sterilizes and kills adult stages, but the utility of this drug for routine field use remains an issue of concern. No macrofilaricidal drugs with efficacy after one or two doses are available for use, delaying the achievement of the elimination or eradication of onchocerciasis and lymphatic filariasis. Moxidectin, a macrocyclic lactone, is currently in clinical trials for onchocerciasis. A few other drugs that have already been approved for use in veterinary practice or in human medicine for other indications are available for investigation. Early drug discovery pipelines are poorly populated and the process of ...
2011-01-01
Tritium bioassay and dosimetry at a CANDU reactors
Energy Technology Data Exchange (ETDEWEB)
Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.
1996-07-01
Secondary hazards of high power laser beam welding
International Nuclear Information System (INIS)
Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)
1996-01-01
International Nuclear Information System (INIS)
The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).
1986-01-01
Radiation hardness of plastic scintillating fiber
International Nuclear Information System (INIS)
We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
Preparation of wood-polymer composites by using ionizing radiation
International Nuclear Information System (INIS)
Radiation-initiated polymerization of styrene and acrylic acid in poplar wood were investigated for the preparation of wood-polymer composites. The direct irradiation method was applied to the monomer adsorbed poplar wood specimens. 8000 Ci "6"0Co source at a dose rate of about 0.4 Mrad/h was used. Furthermore the effects of carbon tetrachloride, methanol, dioxane and acrylonitrile on styrene polymerization were investigated and the reaction rates were calculated for each case. The influence of CCl_4 (10%) on acrylic acid polymerization in poplar wood was also determined. (author).
1982-05-01
Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note
Energy Technology Data Exchange (ETDEWEB)
The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.
1986-01-01
Basic radiation sterilization properties of packaging materials
International Nuclear Information System (INIS)
The foils of various materials were irradiated with "6"0Co with an activity of 11,538 TBq. The minimum radiation dose was 25 kGy. Changes in chemico-physical properties were evaluated by infrared spectroscopy and were not detected after irradiation with 25 kGy. Packing foils were subjected to the following tests: mechanical tests, tests of weld strength, tests of impact resistance, free fall tests, permeability tests for water vapour and microbiological tests. The results of all tests were tabulated. The tests showed that the foils are impermeable for microorganisms and provided the welds are airtight the packed products remain sterile. (J.P.).
1984-11-28
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of the 2003 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.
2001-02-01
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of the 2001 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct and scattered radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.
2002-02-01
Energy Technology Data Exchange (ETDEWEB)
Enzyme-linked Immunosorbent assay systems for the identification of irradiated egg, pork and chicken was developed. Eggs were irradiated in their shells to 0.5{approx}7kGy. Pork was irradiated to 0.5{approx}3kGy and chicken irradiated to 0.5kGy{approx}5kGy. The most sensitive proteins to irradiation were screened by SDS-PAGE and purified. Ovalbumin from egg, salt soluble protein(p) from pork, and salt soluble protein(c) from chicken showed the most sensitivity to irradiation. To investigate for a practical use in identifying of irradiated egg, pork and chicken, competitive ELISA was performed. The binding activity of ovalbumin to anti-ovalbumin IgG was reduced in a dose-dependent manner by irradiating up to 7kGy, and considerably lowered after irradiating at 7kGy. The concentration of 50% inhibition of ovalbumin to IgG was increased to 1.5(0.5kGy){approx}3.7(7kGy) times in an dose-dependent relationship. The binding activity of salt soluble ...
2002-04-01
Ultraviolet radiation in Finland
Energy Technology Data Exchange (ETDEWEB)
Solar ultraviolet radiation is damaging for living organisms due to its high energy pro each photon. The UV radiation is often separated into three regions according to the wavelength: UVC (200-280 nm), UVB (280-320 nm) and UVA (320-400 nm). The most hazardous part, UVC is absorbed completely in the upper atmosphere by molecular oxygen. UVB radiation is absorbed by atmospheric ozone partly, and it is reaching Earth`s surface, as UVA radiation. Besides atmospheric ozone, very important factors in determining the intensity of UVB radiation globally are the solar zenith angle and cloudiness. It may be calculated from global ozone changes that the clear-sky UVB doses may have enhanced by 10-15 % during spring and 5-10 % during summer at the latitudes of Finland, following the decrease of total ozone between 1979-90. The Finnish ozone and UV monitoring activities ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means ...
1989-01-01
International Nuclear Information System (INIS)
Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment planning and means ...
Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation
International Nuclear Information System (INIS)
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, ...
1992-10-25
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...
2007-05-10
British Library Electronic Table of Contents (United Kingdom)
Irradiation of EP-823 (16Cr12MoWsiVNbB) ferritic-martensitic steel with 7-MeV Ni++ ions and with 30- and 70-keV He+ ions at a temperature of 500?C was followed by an increase in the microhardness, which was due to both radiation point defects and changes in the phase composition and the dislocation structure of the steel. It was found that the dependence of the largest relative increase in the microhardness on the concentration of radiation-induced point defects in the near-surface region of the steel under irradiation with different ions correlated with an analogous dependence of the surface segregation of silicon and chromium.
2011-01-01
Production of secondary Deuterium in the atmosphere at various latitudes
Energy Technology Data Exchange (ETDEWEB)
Secondary deuterium in the atmosphere are produced in interactions by primary cosmic rays. The shape of their energy spectrum depends on the primary cosmic ray spectrum incident at the top of the atmosphere. At high energies, the spectral shape depends on the primary spectrum of helium and heavy nuclei. However, at very low energies, specially below the geomagnetic cut-off, the spectral shape depends on the evaporation and recoil processes and hence almost independent of the spectral shape of the primary radiation. It is undertaken a calculation of the secondary deuterium spectrum at small atmospheric depths at various latitudes and the results will be presented.
1995-09-01
International Nuclear Information System (INIS)
With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).
1985-10-22
Radiation therapy for Kasabach-Merritt syndrome. Analysis of unfavorable factors in 5 children
Energy Technology Data Exchange (ETDEWEB)
During the past 10 years, five infants with Kasabach-Merritt syndrome (K-M) receiving radiation therapy were reported. We investigated whether radiation therapy for K-M was useful and what the unfavorable factors of K-M were. During the past 10 years, we have treated five infants with K-M. The syndrome occurred at ages ranging from birth to 4 months. The incidence of female to male ratio was 3:2. Among 5 cases, the site of hemangioma was as follows; shoulder, anterior chest wall, lower abdominal wall, face and neck and inguinal site. All 5 cases received medication to control the coagulopathy including prednisone and blood transfusion at first. Because the platelet count and the bleeding tendency did not improve in any case, these cases received radiation therapy. Total dose ranged from 5 to 10 Gy and fraction-size ranged from 0.5 to 1.75 Gy. Irradiation session was 2 or 3 times per week. In 5 cases, 4 ...
1996-03-01
Measurement of skin dose in primary irradiation of maxillary sinus carcinoma
Energy Technology Data Exchange (ETDEWEB)
Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.
1991-03-01
British Library Electronic Table of Contents (United Kingdom)
Sulfur mustard (HD) is an alkylating and cytotoxic chemical warfare agent, which inflicts severe skin toxicity and an inflammatory response. Effective medical countermeasures against HD-caused skin toxicity are lacking due to limited knowledge of related mechanisms, which is mainly attributed to the requirement of more applicable and efficient animal skin toxicity models. Using a less toxic analog of HD, chloroethyl ethyl sulfide (CEES), we identified quantifiable inflammatory biomarkers of CEES-induced skin injury in dose- (0.05-2 mg) and time- (3-168 h) response experiments, and developed a CEES-induced skin toxicity SKH-1 hairless mouse model. Topical CEES treatment at high doses caused a significant dose-dependent increase in skin bi-fold thickness indicating edema. Histopathological e...
2009-01-01
Creation and filling of thermoluminescence traps during irradiation
Energy Technology Data Exchange (ETDEWEB)
A mathematical model has been constructed to describe the creation and filling of thermoluminescence traps during irradiation. Processes considered include trap filling, recombinations both between free charges and between free and trapped charges and thermal de-trapping. Also a simple trap creation term, linear with dose, has been included. A computer program has been written in order to solve the system of differential equations describing the various charge carrier flows during irradiation. The model and the program are described and the results of the application of the model to some simple energy-level schemes are discussed. Thermal de-trapping and band-to-band recombinations can introduce a dose rate dependence into the accumulation of trapped charge, whilst trap creation leads to the supralinear growth of charge trapped at certain defects with increasing dose.
1986-01-01
British Library Electronic Table of Contents (United Kingdom)
9-cis-UAB30 is a potential chemopreventative agent that has been shown to be effective on many different types of tumors. The safety and toxicity of 9-cis-UAB30 had not been previously established. These studies were conducted to evaluate the potential toxicity and pharmacokinetics in a rodent and a nonrodent species for the purpose of investigational new drug submission. Oral gavage administration of 9-cis-UAB30 at the doses 0, 3, 15, and 100 ?mg/kg/day to CD? rats for 28 days showed a dose-dependent (although not dose-proportional) increase in plasma drug levels in week 4. The liver was the target organ for toxicity of 9-cis-UAB30. Hepatomegaly along with increases in serum aspartate-aminotransferase and alkaline-phosphatase levels were seen in rats. Moderate hypoalbuminemia and hyperglo...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Experiments were designed to elucidate whether or not the irradiated bone marrow cells receive any stimulation for the self-replication and differentiation from normal 'stromal' cell colonies in the bone marrow cell culture in vitro. When irradiated or unirradiated bone marrow cells were overlaid on the normal adherent cell colonies, the proliferation of haemopoietic stem cells was supported, the degree of the stimulation depending on the starting cellular concentration. There was, however, no significant changes in the concentration of either CFUs or CFUc regardless of the dose of irradiation on the bone marrow cells overlaid. This was a great contrast to the dose-dependent decrease of CFUs or CFUc within the culture in which both the stem cells and stromal cells were simultaneously irradiated. These results suggest that the balance of self-replication and differentiation of the haemopoietic stem cells is ...
1981-09-01
Comparison of 6 MV and 18 MV photons for IMRT treatment of lung cancer
International Nuclear Information System (INIS)
Background and purpose: To compare 6 MV and 18 MV photon intensity modulated radiotherapy (IMRT) for non-small cell lung cancer. Materials and methods: Doses for a cohort of 10 patients, typical for our department, were computed with a commercially available convolution/superposition (CS) algorithm. Final dose computation was also performed with a dedicated IMRT Monte Carlo dose engine (MCDE). Results: CS plans showed higher D _9_5_% (Gy) for the GTV (68.13 vs 67.36, p = 0.004) and CTV (67.23 vs 66.87, p = 0.028) with 18 than with 6 MV photons. MCDE computations demonstrated higher doses with 6 MV than 18 MV in D _9_5_% for the PTV (64.62 vs 63.64, p = 0.009), PTV_o_p_t_i_m (65.48 vs 64.83, p = 0.014) and CTV (66.22 vs 65.64, p = 0.027). Dose inhomogeneity was lower with 18 than with 6 MV photons for GTV (0.08 vs 0.09, p = 0.007) and CTV (0.10 vs 0.11, p = 0.045) in CS but not MCDE ...
2007-01-01
The effect of a metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations
International Nuclear Information System (INIS)
Prostate and cervical cancer patients are often treated with external X-ray beams of bi-lateral incidence. Such treatment may incur some dose effect that cannot be predicted precisely in commercial treatment planning systems (TPS) for patients having undergone total hip replacement. This study performs a Monte Carlo (MC) simulation and an analytical calculation (convolution superposition algorithm which is implemented in ADAC TPS) of a 6 MV, 5x5 cm"2 X-ray beam incident into water with the existence of hip prosthesis, e.g. Ti6Al4V and CoCrMo alloy. The results indicate that ADAC TPS cannot precisely account for the scatter and backscatter radiation that a metal hip prosthesis causes. For percent depth dose (PDD) curves, the maximum underdosage of ADAC TPS up to 5 mm above the interface between dense material and water is 5%, 20% and 27% for PDD_B_o_n_e, PDD_T_i and PDD_C_o, respectively. The dose ...
2002-07-01
Use of gamma radiation for thermoplastics synthesis
International Nuclear Information System (INIS)
Samples of vynil-benzene and vinyl acetate were irradiated with gamma rays from a sup(60)Co source. Viscosity analysis performed by using the method of Stokes showed an increase in the viscosity of the materials up to the total solidification for increased doses of gamma rays. This result characterized the formation of macromolecules of two thermal plastics, the poly (vinyl-benzene) and the poly (vinyl acetate). (author).
1991-05-27
International Nuclear Information System (INIS)
The radiation decimal reduction dose (D_1_0) of toxigenic Vibrio cholerae O1 El Tor, Inaba was determined in vitro (0.13 kGy) and in inoculated fresh fillets of saurel (Trachurus picturatus murphyi) (0.12 kGy) and another Pacific fish species known in Peru as ''lisa'', Mugil cephalus (0.13 kGy), both of which are frequently consumed raw in ''ceviche''. The D_1_0 value was similarly determined in tails of the shrimp species Penaeus vannamei (0.13 kGy). In a second phase of the study, radiation doses in the range 1.0-4.0 kGy were evaluated for use in microbiological shelf-life extension of the selected seafood, and for adverse effects on various sensory attributes (appearance, odor, flavor, and texture). A dose of 1.0 kGy doubled the microbiological shelf-life of fish fillets during post-irradiation storage at 0-1 deg. C to approximately 30 days. This dose was ...
2001-04-01
Energy Technology Data Exchange (ETDEWEB)
Building materials contain low concentrations of natural radioactive materials, causing a radiation dose for occupants of houses. Governmental policies and regulations with respect to radon emission are or will be implemented. An overview is given of recent developments. 3 refs.
2000-03-01
Power MOSFET transistors hardening: way to proceed and characterization
International Nuclear Information System (INIS)
SGS-Thomson and CNES significantly hardened a power MOSFET transistor against heavy ions and cobalt 60 total dose. The influence of the major technological steps on the component radiation sensitivity has been analyzed. Then the optimization has been carried out, using booth computerized simulation and experimental data. (D.L.). 5 refs., 8 figs.
Late effects of inhaled Pu(NO_3)_4 in rats
International Nuclear Information System (INIS)
Rats that inhaled "2"3"9Pu(NO_3)_4 or "2"3"8Pu(NO_3)_4 developed lung tumors and bone tumors. Lung tumors were clearly associated with Pu inhalation (accumulated dose to lung, 1 rad to 5000 rads); bone tumors could not be unequivocally related to the radiation insult.
1977-05-01
In vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation
UK PubMed Central (United Kingdom)
BackgroundApoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV...Full Text Available
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
