WorldWideScience
1

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

3

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. ...

2001-01-01

4

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

5

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the ...

2003-08-17

6

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

7

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

9

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

10

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the ...

2003-03-04

11

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

12

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

13

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

14

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

15

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

16

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

17

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

18

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

19

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

20

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

21

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

22

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

23

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

24

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

25

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

26

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the ...

2007-01-01

27

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

28

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

29

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

30

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

31

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are ...

1996-01-01

32

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

33

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

34

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

35

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

36

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

37

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

38

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the ...

2007-01-01

39

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization ...

40

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

41

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

42

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

43

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation ...

1991-03-13

44

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

46

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For ...

2006-11-13

47

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton scattering sources and we ...

2009-09-01

48

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is ...

1980-01-01

49

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

50

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

51

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

52

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated ...

1992-10-25

53

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

54

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

55

Studies on formation and structures of ultrafine Cu precipitates in Fe-Cu model alloys for reactor pressure vessel steels using positron quantum dot confinement in the precipitates by their positron affinity. JAERI's nuclear research promotion program, H11-034 (Contract research)  

Energy Technology Data Exchange (ETDEWEB)

Positron annihilation experiments on Fe-Cu model dilute alloys of nuclear reactor pressure vessel (RPV) steels have been performed after neutron irradiation in JMTR. Nanovoids whose inner surfaces were covered by Cu atoms were clearly observed. The nanovoids transformed to ultrafine Cu precipitates by dissociating their vacancies after annealing at around 400degC. The nanovoids and the ultrafine Cu precipitates are strongly suggested to be responsible for irradiation-induced embrittlement of RPV steels. Effects of Ni, Mn and P addition on the nanovoid and Cu precipitate formations were also studied. The nanovoid formation was enhanced by Ni and P, but suppressed by Mn. The Cu precipitates after annealing around 400degC were almost free from these doping elements and hence were pure Cu in the chemical composition. Furthermore the Fermi surface of the 'embedded' Cu precipitates with a body centered cubic crystal structure was obtained from two ...

2003-03-01

56

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be ...

2009-07-23

57

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

58

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

59

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

60

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For ...

2005-11-23

61

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and ...

1995-11-01

62

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...

2007-06-11

63

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...

2007-08-21

64

Conceptual design of the ATLAS EM muon chamber support structures  

CERN Document Server

The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.

1998-01-01

65

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the non-destructive evaluation (NDE) of ...

2001-07-01

66

Facility for studying photon-neutron reactions under a beam of braking radiation  

International Nuclear Information System (INIS)

A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.

67

Cluster-loop structure influence on molybdenum radiation hardening  

International Nuclear Information System (INIS)

Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).

1990-05-22

68

The structure of the 4.743 MeV state in "8"8Sr  

International Nuclear Information System (INIS)

... states gamma radiation mev range 01-10 photonuclear reactions polarization

69

Electroluminescence Study of Green Be-Contained II-VI ...  

Science.gov (United States)

... laser structure. However, still the greater part (60%) of emitted photons is a result of a spontaneous radiation process. In ...

2000-06-23

70

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that ...

2003-09-15

71

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

72

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

73

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

74

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of ...

2009-11-02

75

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

76

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing ...

2004-12-21

77

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

78

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

79

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

80

Some considerations about future interferometric GW detectors  

International Nuclear Information System (INIS)

The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.

2004-03-07

81

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward ...

2004-01-01

82

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

83

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

84

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

85

Difference between delayed radiation-necroses of the cerebral hemispheres and midline: its bearing in radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Delayed cerebral necroses after irradiation are to be divided into hemispheric and midline lesions, as they differ from each other in several aspects. Apart from the symptoms, they are differing in the duration of latency, in the course and prognosis, and also with regard to morphology. Though there is no doubt that radiation tolerance of cerebral midline structures is relatively limited, on biological grounds, evidence of a difference between the tolerated doses could not be given from the existent inhomogeneous radiation data, with the help of the NSD-concept. Radiation planning for the region of the head, nevertheless, carefully should avoid in every case to involve the structures of the cerebral midline.

1980-08-01

86

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, ...

2004-10-13

87

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

88

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron ...

1997-07-01

89

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm ...

1995-10-01

90

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab ...

2005-08-01

91

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

92

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy ...

1993-10-13

93

Development of a computerized portal verification scheme for pelvic treatment fields  

International Nuclear Information System (INIS)

Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied ...

1996-09-01

94

Prevention and treatment of functional and structural radiation injury in the rat heart by pentoxifylline and alpha-tocopherol  

UK PubMed Central (United Kingdom)

PurposeRadiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of PTX and α-tocopherol on...Full Text Available

2008-09-01

95

Inhibited spontaneous emission by a Rydberg atom  

Science.gov (United States)

Spontaneous radiation by an atom in a Rydberg state is inhibited by use of parallel conducting planes to eliminate the vacuum modes at the transition frequency. Spontaneous radiation emission is observed to turn off abruptly at the cutoff frequency of the waveguidelike structure, and the natural lifetime is measured to increase by a factor of at least 20.

1985-11-11

96

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

97

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

98

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the ...

1999-07-01

99

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...

2006-02-15

100

Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films  

British Library Electronic Table of Contents (United Kingdom)

Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.

2008-01-01

101

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be ...

1983-08-26

102

LC-MS analysis in the e-beam and gamma radiolysis of metoprolol tartrate in aqueous solution: Structure elucidation and formation mechanism of radiolytic products  

British Library Electronic Table of Contents (United Kingdom)

E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.

2006-01-01

103

Forward Physics with the CMS experiment at the Large Hadron Collider  

CERN Document Server

multi-parton interactions and underlying event structure, $\\gamma$-mediated processes and luminosity determination, Monte Carlo tuning and even MSSM Higgs discovery in central exclusive production. In this article, the forward detector instrumentation around the CMS interaction point is described and the prospects for diffractive and forward physics using the CMS forward detectors are summarized. In addition, first observation of forward jets as well as early measurements of the forward energy flow in the pseudorapidity range $3.15

2010-01-01

104

Circuit design of PMT readout module for detector prototype of Daya Bay reactor neutrino experiment  

International Nuclear Information System (INIS)

This paper describes the design of PMT readout module for detector prototype of Daya Bay Reactor Neutrino Experiment. According to the design requirements of the readout module, the basic structure of the readout module is discussed. This paper also discusses how to realize the charge measurement and time measurement and data processing using a high performance FPGA. The DAQ system including three readout modules and one trigger module are well commissioned and doing data taking now. (authors)

2006-10-21

105

Quantum locking of mirrors in interferometric measurements  

International Nuclear Information System (INIS)

We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.

2004-03-07

106

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

107

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

108

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

109

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...

1983-06-01

110

Adaptive Radiation for Lung Cancer  

UK PubMed Central (United Kingdom)

The challenges of lung cancer radiotherapy are intra/inter-fraction tumor/organ anatomy/motion changes and the need to spare surrounding critical structures. Evolving radiotherapy technologies, such...Full Text Available

2011-01-01

111

Temperature dependence of the performance of ultraviolet detectors  

Energy Technology Data Exchange (ETDEWEB)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause ...

2003-08-21

112

Temperature dependence of the performance of ultraviolet detectors  

International Nuclear Information System (INIS)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause ...

2003-08-21

113

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron ...

2010-09-07

114

Radiative corrections to the atomic levels in a periodic electromagnetic field  

Energy Technology Data Exchange (ETDEWEB)

The influence of a periodic electromagnetic field on the radiative corrections to the atomic energy levels is studied for the case of ''strong fields'' for which the interaction between the atom and field is of the order or greater than the radiative effects. The analysis is carried out on the basis of the Schwinger-Dirac equation for the propagation function of a bound electron in the field and on the basis of the density matrix in the Furry representation. It is shown that in the strong field approximation the radiative shifts and widths are manifest as radiative corrections to the quasi-energies. In super-high resolution experiments intensity effects in the radiative corrections to the atomic levels are obtained in the case of single-photon resonance. Some multiphoton processes are condidered by taking into account the effect of the field on ...

1982-12-01

115

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

116

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

117

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and ...

2005-06-11

118

Photoconductive ultraviolet detectors based on ZnO films  

Energy Technology Data Exchange (ETDEWEB)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve ...

2006-12-15

119

Photoconductive ultraviolet detectors based on ZnO films  

International Nuclear Information System (INIS)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve ...

2006-12-15

120

Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces  

Science.gov (United States)

We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f ...

2006-07-01

121

SENSITIVITY STUDIES FOR AN IN-SITU PARTIAL DEFECT DETECTOR (PDET) IN SPENT FUEL USING MONTE CARLO TECHNIQUES  

Energy Technology Data Exchange (ETDEWEB)

This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.

2008-04-28

122

Quantification of thin film crystallographic orientation using X-ray diffraction with an area detector  

Energy Technology Data Exchange (ETDEWEB)

As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.

2010-02-19

123

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

124

Comparison of energy flows in deep inelastic scattering events with and without a large rapidity gap  

Energy Technology Data Exchange (ETDEWEB)

Energy flows in deep inelastic electron-proton scattering are investigated at a centre-of-mass energy of 296 GeV for the range Q{sup 2}{>=}10 GeV{sup 2} using the ZEUS detector. A comparison is made between events with and without a large rapidity gap between the hadronic system and the proton direction. The energy flows, corrected for detector acceptance and resolution, are shown for these two classes of events in both the HERA laboratory frame and the Breit frame. From the differences in the shapes of these energy flows we conclude that QCD radiation is suppressed in the large-rapidity-gap events compared to the events without a large rapidity gap. (orig.)

1994-07-01

125

The development and testing of emissivity enhancement coatings for thermophotovoltaic (TPV) radiator applications  

Energy Technology Data Exchange (ETDEWEB)

One requirement of a thermophotovoltaic (TPV) radiator is to efficiently emit photons at high temperatures to TPV cells for conversion to electric power. Because many candidate radiator materials with adequate structural properties display low emissivity, coatings or other surface modifications are required for enhancement of emissivity. Six plasma sprayed coatings and one textured surface demonstrated adequate thermal stability and emittance values of 0.8 or greater. Promising attributes of modified surfaces are identified.

1999-03-01

129

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

Energy Technology Data Exchange (ETDEWEB)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-15

130

Structure analysis of ferrite in deformed pearlitic steel by means of X-ray diffraction method with synchrotron radiation  

International Nuclear Information System (INIS)

Structure of ferrite in drawn pearlitic steel containing 0.9 mass% C was investigated with X-ray diffraction technique using synchrotron radiation. In the detailed analysis of diffraction peaks of ferrite during the drawing process, it was experimentally revealed that the transformation of ferrite from bcc to bct due to the supersaturation of carbon in ferrite of heavily drawn pearlitic steel.

2004-07-01

131

Radiation damage on amorphous metals. [Helium ion, neutron and gamma ray irradiation  

Energy Technology Data Exchange (ETDEWEB)

The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.

1982-04-01

132

A final report for: Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge ...

1999-04-01

133

A Radiation Laboratory Curriculum Development at Western Kentucky University  

Science.gov (United States)

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and ...

2009-03-10

134

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

135

Construction and Calibration of the Laser Alignment System for the CMS Tracker  

CERN Document Server

The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser ...

2006-01-01

136

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. ...

2004-03-09

137

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

138

Neutron scattering studies in the actinide region. Progress report, August 1, 1992--July 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Prompt fission neutron energy spectra for {sup 235}U and {sup 239}Pu; Two-parameter measurement of nuclear lifetimes; ``Black`` neutron detector; Data reduction techniques for neutron scattering experiments; Inelastic neutron scattering studies in {sup 197}Au; Elastic and inelastic scattering studies in {sup 239}Pu; and neutron induced defects in silicon dioxide MOS structures.

1993-09-01

139

High energy physics  

International Nuclear Information System (INIS)

The research of the CELLO collaboration is reviewed. After a description of the CELLO detector tests of QCD and hadronic final states by determination of the strong coupling constant and studies of inclusive production of electrons and muons in multihadronic events in e"+e"- annihilation are described. Then studies of deep inelastic e#gamma# scattering with lepton pair production and the study of the structure function of the photon are briefly described. Finally studies on QED processes are described together with tau decays. (HSI).

1983-11-01

140

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...

2010-10-01

141

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray ...

1987-05-13

142

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

143

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

144

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

145

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

146

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and increases in FWHM ...

1998-12-01

147

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

148

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

149

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

150

Artificial intelligence: the future in nuclear plant maintenance  

Energy Technology Data Exchange (ETDEWEB)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-12-01

151

Artificial intelligence: the future in nuclear plant maintenance  

International Nuclear Information System (INIS)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-09-23

152

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

153

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to measure the K shell fluorescence parameters such as ...

2003-11-01

154

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

155

Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign  

Energy Technology Data Exchange (ETDEWEB)

Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers ...

2007-08-01

156

Specific features of radiation damage in titanium alpha-alloys  

International Nuclear Information System (INIS)

Titanium base 'alpha'-alloys (Pt-7M, RK-20 and Ti-5Al-2Zr-1.5V) are considered for their behaviour under neutron irradiation. The role of alloying elements in radiation hardening is discussed depending of neutron fluence and irradiation temperature. For PK-20 alloy three stages of change in mechanical properties are revealed which are following: incubation period and weak hardening, intense radiation hardening, radiation hardening attenuation. Irradiation temperature rise results in an increase of incubation period and threshold neutron fluence. A special attention is paid to hydrogen absorption in #alpha#-titanium alloys under irradiation. It is concluded that titanium base 'alpha'-alloys are serviceable as structural materials in nuclear plants with allowance made for peculiar features of their radiation behaviour. 4 refs.; 7 figs.; 1 tab.

157

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

158

Research in heavy-ion nuclear physics. [Dept. of Physics and Astronomy, The Univ. of Kansas, Lawrence, Kansas  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to [sup 47]V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of [sup 28]Al through three different entrance channels. Angular distributions are shown for different mass channels of the [sup 29]Si+[sup 27]Al reaction at E[sub lab] = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the [sup 24]Mg+[sup 24]Mg reaction; cross sections for binary fragment emission are shown for E[sub lab] = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

159

Research in heavy-ion nuclear physics. Annual progress report, May 1, 1992--April 30, 1993  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to {sup 47}V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of {sup 28}Al through three different entrance channels. Angular distributions are shown for different mass channels of the {sup 29}Si+{sup 27}Al reaction at E{sub lab} = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the {sup 24}Mg+{sup 24}Mg reaction; cross sections for binary fragment emission are shown for E{sub lab} = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

160

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits ...

1997-12-31

161

Useful vacancies: Positron beam interrogation of fluorine-vacancy complexes in semiconductor device structures  

Energy Technology Data Exchange (ETDEWEB)

The formation, migration and agglomeration in silicon of fluorine-vacancy complexes have been monitored by single-detector Doppler broadening spectroscopy. After electronics engineers found that fluorine ion implantation effectively eliminated the transient-enhanced diffusion of dopants in the creation of ultra-shallow junctions, a vital step in the further miniaturization of device structures, positron beams have played a pivotal role in providing an insight into the mechanisms underlying this phenomenon, being able to detect FV complexes in implanted and annealed samples. Secondary Ion Mass Spectrometry has provided complementary information on fluorine concentrations so that the nature of the F{sub m}V{sub n} complexes can be further assessed. New results on Si and SiGe structures are presented.

2008-10-31

162

Evidence for a Narrow Near-Threshold Structure in the $J/\\psi\\phi$ Mass Spectrum in $B^+\\to J/\\psi\\phi K^+$ Decays  

Energy Technology Data Exchange (ETDEWEB)

Evidence is reported for a narrow structure near the J/{psi}{phi} threshold in exclusive B{sup +} {yields} J/{psi}{phi}K{sup +} decays produced in {bar p}p collisions at {radical}s = 1.96 TeV. A signal of 14 {+-} 5 events, with statistical significance in excess of 3.8 standard deviations, is observed in a data sample corresponding to an integrated luminosity of 2.7 fb{sup -1}, collected by the CDF II detector. The mass and natural width of the structure are measured to be 4143.0 {+-} 2.9(stat) {+-} 1.2(syst) MeV/c{sup 2} and 11.7{sub -5.0}{sup +8.3}(stat) {+-} 3.7(syst) MeV/c{sup 2}.

2009-03-01

163

AlxGa1-xN/GaN multi-quantum-well ultraviolet detector based on p-i-n heterostructures  

British Library Electronic Table of Contents (United Kingdom)

We report on characterization of a set of AlGaN/GaN multiple-quantum-well (MQW) photodetectors. The model structure used in the calculation is the p-i-n heterojunction with 20 AlGaN/GaN MQW structures in i-region. The MQW structures have 2nm GaN quantum well width and 15nm AlxGa1-xN barrier width. The cutoff wavelength of the MQW photodetectors can be tuned by adjusting the well width and barrier height. Including the polarization field effects, on increasing Al mole fraction, the transition energy decreases, the total noise increases, and the responsivity has a red shift, and so the detectivity decreases and has a red shift.

2009-01-01

164

Structural and functional aspects of radiation adrenalopathy  

Energy Technology Data Exchange (ETDEWEB)

As part of a combined study of the responses of the mouse adrenal gland and kidney to X-irradiation, the weight of adrenal glands, the relative volumes of the cortex and medulla and the aldosterone output were measured at predetermined times after irradiation of the left organs only.

1986-01-01

165

Some properties of low-mass stellar models with chemically inhomogeneous neutral-stability zones  

Energy Technology Data Exchange (ETDEWEB)

Several low-mass models with an inhomogeneous radiative core and a convective envelope are investigated, the entire core or its upper portion being treated as a zone of neutral stability. Mixing by convective overshoot will then give rise to unstable structure.

1983-03-01

166

Potential of cattails as an energy source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Research on the feasibility of growing cattails as an energy crop is described. The following topics are included: productivity in natural strands, germination requirements for seed, establishing stands by seeding, rhizome dormancy and development, harvesting and stand establishment, and analysis of canopy structure and radiation profiles in a natural community. (MHR)

1980-01-01

167

Identification of novel DNA repair proteins via primary sequence, secondary structure, and homology  

UK PubMed Central (United Kingdom)

BackgroundDNA repair is the general term for the collection of critical mechanisms which repair many forms of DNA damage such as methylation or ionizing radiation. DNA repair has...Full Text Available

168

Biology and Medicine Division annual report, 1978-1979  

Science.gov (United States)

Summaries of research projects conducted during 1978 and 1979 are presented. Subject areas include research medicine, cancer research, environmental physiology, radiation biophysics, and structural biophysics. (ACR)

1979-01-01

169

Biodiversity of Costa Rican salamanders: Implications of high levels of genetic differentiation and phylogeographic structure for species formation  

UK PubMed Central (United Kingdom)

Although salamanders are characteristic amphibians in Holarctic temperate habitats, in tropical regions they have diversified evolutionarily only in tropical America. An adaptive radiation centered...Full Text Available

2000-02-15

170

The radiative decays {phi}{yields}{gamma}a{sub 0}/f{sub 0} in the molecular model for the scalar mesons  

Energy Technology Data Exchange (ETDEWEB)

We investigate the radiative decays of the {phi}-meson to the scalar mesons a{sub 0}(980) and f{sub 0}(980). We demonstrate that, contrary to earlier claims, these decays should be of the same order of magnitude for a molecular state and for a compact state and, therefore, the available experimental information is consistent with both a molecular as well as a compact structure of the scalars. Thus, the radiative decays of the {phi}-meson into scalars establish a sizable K anti K component of the scalar mesons, but do not allow to discriminate between molecules and compact states. (orig.)

2005-06-01

171

Anomaliously high radiation hardening of iron-chromium alloys  

International Nuclear Information System (INIS)

Argon ions irradiation of 12% Cr steels and Fe/Cr alloys results in the hardening up to 10000 MPa. This value exceeds the hardening level even for martensitic transformation. Along with the increase of microhardness following irradiation the shape of X-ray graph of the affected materials changes considerable. Hardening value and behavior are determined by temperature radiation doze, preliminary ageing, extent of cold strain and alloying. The odserved phenomenon is supposed to be caused by irradiation-induced structural transformations. Reversibility of radiation hardening of the materials in question was observed.

172

Estimating extreme values of thermal gradients in concrete structures  

British Library Electronic Table of Contents (United Kingdom)

Temperature variations due to climate changes are a major cause of movements in a concrete structure, both in the longitudinal and transversal directions and between different parts of the structure. If these movements are restrained, stresses will be induced which may contribute to cracking. The movements are caused by complex interactions of several factors such as solar radiation, air temperature, long-wave heat radiation and wind speed. To predict the varying thermal conditions in a concrete structure a finite element model has been used. A validation of the model has been performed using field measurements in a concrete slab together with climate data from the Swedish Meteorological and Hydrological Institute to be able to use the model for simulations over long time periods and for s...

2011-01-01

173

Radiation effect on optical, electrophysical and surface properties of GaAlAs heterostructures  

Energy Technology Data Exchange (ETDEWEB)

A study was made on the effect of 3.5 MeV electron irradiation on the properties of light-emissive structure based on GaAlAs. It is shown that a considerable decrease in the emitted light intensity as a result of electron irradiation not accompanied by changes in recombination- and electric properties of the mentioned structures. It is established by the electron-microscopy and Auger-spectroscopy meazurements that electron irradiation causes the occurrence of regions of free aluminium clusters on the external surface of the structure n-layer. The number and the sizes of the regions depend on the electron doze. It was assumed that the mentioned regions can play a role of attenuation filter for the light emitted by the structure.

1984-07-01

174

Overview of US LMFBR Structural Materials Mechanical Properties Program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.

1983-01-01

175

Overview of U.S. LMFBR structural materials mechanical properties program  

International Nuclear Information System (INIS)

This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).

1983-10-10

176

Rayleigh scattering of Moessbauer radiation in hyaluronate oriented fibres  

Energy Technology Data Exchange (ETDEWEB)

The Rayleigh scattering of Moessbauer radiation has been measured on highly oriented fibres of Na-hyaluronate at different hydration levels. The elastic- and-inelastic-scattering intensities, measured as a function of the scattering vector Q, have provided information on the dynamic structuring of the water molecules to the polysaccharidic chains.

1996-02-01

177

Hardening process relating to the irradiation of active electronic components and large hardened components  

International Nuclear Information System (INIS)

A patent is claimed for the invention of a hardening (ionizing radiation resistance) process for MOS type components and CMOS or bipolar type components. The ionizing radiation effect on those systems is the electron-hole pair production, which induces interference phenomena. The MOS main structure is successively composed of a silicon substrate layer, a layer of an irradiation resistant material and a layer of partially monocrystalline silicon.

1988-12-09

178

Computer simulation and radiation hardening of power devices to protect against failures induced by heavy ions  

International Nuclear Information System (INIS)

Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).

179

Electronic structure of clusters of A-15 compounds with radiation induced defects  

Energy Technology Data Exchange (ETDEWEB)

The electronic structure of the clusters (V/sub 3/Si/sub 4/)/sup 12 -/, (Nb/sub 3/Sn/sub 4/)/sup 12 -/(Mo/sub 3/Ge/sub 4/)/sup 15 -/ in crystalline V/sub 3/Si, Nb/sub 3/Sn, Mo/sub 3/Ge compounds is calculated by the Extended Hueckel method. The influence of different types of radiation induced defects on the density of states at the Fermi level (the anti-site defects, the displacement of atoms in linear chains, the vacancy-interstitial type defects) is considered.

1981-05-01

180

Electronic structure of clusters of A-15 compounds with radiation induced defects  

International Nuclear Information System (INIS)

The electronic structure of the clusters [V_3Si_4]"1"2"-, [Nb_3Sn_4]"1"2"-[Mo_3Ge_4]"1"5"- in crystalline V_3Si, Nb_3Sn, Mo_3Ge compounds is calculated by the Extended Hueckel method. The influence of different types of radiation induced defects on the density of states at the Fermi level (the anti-site defects, the displacement of atoms in linear chains, the vacancy-interstitial type defects) is considered. (author).

181

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum ...

1998-03-01

182

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows ...

183

Effect of radiation dose on the properties of natural rubber nanocomposite  

Energy Technology Data Exchange (ETDEWEB)

Effect of radiation dose and carbon nanotubes (CNT) on the mechanical properties of standard Malaysian rubber (SMR) was investigated in this study. SMR nanocomposites containing 1-7 phr CNT were prepared using the solvent casting method and the nanocomposites were radiated at doses of 50-200 kGy. The change in mechanical properties, especially, tensile strength (Ts), elongation at break (Eb), hardness and tensile modulus at 100% elongation (M{sub 100}) were studied as a function of radiation dose. The structure and morphology of reinforced natural rubber was investigated by FESEM, TEM and AFM in order to gain further evidence on the radiation-induced crosslinking. It was found that the Ts, M{sub 100} and the hardness of the SMR/CNT nanocomposites significantly increased with radiation dose; the elongation at break exhibited an increase up to 100 kGy, and a ...

2010-12-15

184

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...

1996-12-01

185

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

186

Results of radon concentration measurements in some regions of Russia  

Energy Technology Data Exchange (ETDEWEB)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal ...

1996-01-01

187

Results of radon concentration measurements in some regions of Russia  

International Nuclear Information System (INIS)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for ...

188

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the ...

2007-01-01

189

Correction for loss of track density due to overlapping track on SSNTD  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This ...

1990-06-01

190

Identification of the #pi#g_9_/_2 band new levels in "1"2"1Cs  

International Nuclear Information System (INIS)

The #pi#g_9_/_2 band structure in "1"2"1Cs is obtained. The experiment was performed at the HI-13 MV tandem accelerator of China Institute of Atomic Energy. The excited states of "1"2"1Cs were populated via the reaction "1"1"2Sn("1"2C, p2n). The #gamma#-#gamma# coincidence data were taken with five BGO-AC HpGe detectors at beam energy of 60 Mev. The energy-level schemes of "1"2"1Cs is presented.

1992-01-01

191

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

192

Core localized toroidal Alfven eigenmodes destabilized by energetic ions in the CHS heliotron/torsatron  

Energy Technology Data Exchange (ETDEWEB)

Toroidal Alfven eigenmodes (TAE) destabilized by the pressure gradient of energetic alpha particles may expel the alpha particles before thermalization. TAE is important for tokamaks, and for helical systems (stellarators) as well. In CHS (compact helical system) TAE localized in the plasma core are destabilized when the plasma current is induced by co-injection of neutral beams. The observed TAE exhibits a ballooning nature. The internal structure of TAE was measured with a soft X-ray detector. The soft X-ray fluctuations level for TAE is too low to obtain the radial profiles of fluctuation intensities. (Tanaka, M.)

1999-09-01

193

Solar energy apparatus with apertured shield  

Energy Technology Data Exchange (ETDEWEB)

This paper describes in an apparatus for absorbing a beam of concentrated solar energy and which includes a cavity receiver with an inlet for transmission thereinto of solar radiation, a protective apertured shield means about the inlet. It comprises: rigid support means fixed to the periphery of the inlet and projecting radially inwardly therefrom to define a generally central aperture area through which the solar radiation can pass into the cavity receiver; and non-structural blanket means spread over the rigid support means between the periphery of the inlet and the aperture area, the material having a high temperature capability and providing for infra-red radiation insulation, while remaining relatively cool when subjected to solar radiation.

1989-07-25

194
199

Electronic structure of the Ru(0001) surface  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the electronic structure of ruthenium. Synchrotron radiation in the range from 15 to 45 eV and angle-resolved ultraviolet photoemission are used to map the energies of the electronic states. The Fermi surface of Ru is determined using angle-resolved ultraviolet photoemission spectroscopy. The experimental results are compared with calculated photoemission spectra obtained within the framework of the one-step model of photoemission. (author)

2000-03-13

200

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

201

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

202

Modulation of the intestinal response to ionizing radiation by anticoagulant and non-anticoagulant heparins.  

Science.gov (United States)

Endothelial dysfunction is involved in radiation responses in many normal tissues, including intestine. Endothelium-directed interventions ameliorate intestinal radiation injury (radiation enteropathy) in animal models, and anecdotal reports also suggest a beneficial effect of heparin. This study assessed low molecular weight heparin as an intestinal radiation response modifier. Rats underwent localized small bowel irradiation. Groups of rats were treated with saline, nadroparin (3 mg/kg/d), or a non-anticoagulant heparin (SR80258, 3 mg/kg/d), from 3 days before to 2 weeks after irradiation. The intestinal radiation response was assessed 2 weeks and 6 weeks after irradiation using quantitative histology; morphometry, and cellular and molecular end-points. Compared to vehicle-treated controls, nadroparin significantly exacerbated structural ...

2005-11-01

203

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 ...

2006-12-15

204

Decays of "1"0"1Mo and "1"0"1Tc  

International Nuclear Information System (INIS)

The activities "1"0"1Mo and "1"0"1Tc produced from neutron capture by natural Mo were chemically separated and studied using Ge(Li) #gamma#-ray detectors. Out of 185 transitions observed in the decay of "1"0"1Mo, 170 were assigned to 44 excited levels in "1"0"1Tc. For the decay of "1"0"1Tc, 26 of 27 transitions were placed among 10 excited levels in "1"0"1Ru. The interpretation of the "1"0"1Tc level scheme using the shell-model approach is not satisfactory even for a five-particle calculation. Systematics of odd-A level structures in the region of A=101 indicate that the level structure of "1"0"1Tc could be due partly to the onset of collective effects.

205

An evaluation of the embedment of a Radio Frequency Integrated Circuit with a temperature detector in building envelopes for energy conservation  

British Library Electronic Table of Contents (United Kingdom)

Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...

2011-01-01

206

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

207

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

208

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

209

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

210

Method for determining hydrogen mobility as a function of temperature in superconducting niobium cavities  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.

2008-03-11

211

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

212

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

213

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

214

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

215

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

216

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

217

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

218

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

219

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

220

Short-term inhibition of ADP-induced platelet aggregation by clopidogrel ameliorates radiation-induced toxicity in rat small intestine.  

Science.gov (United States)

Endothelial dysfunction and increased platelet aggregation may be involved in the pathogenesis of normal tissue radiation toxicity. This study assessed clopidogrel, an inhibitor of ADP-induced platelet aggregation, as a modulator of intestinal radiation injury (radiation enteropathy). Rat small intestine was exposed to 21 Gy X-radiation. Clopidogrel (20 mg/kg/day) or vehicle was administered from 2 days before to 10 days after irradiation. Structural radiation injury, neutrophil infiltration, smooth muscle cell proliferation, collagen content, and TGF-beta1 expression were assessed 2 weeks (early phase) and 26 weeks (delayed phase) after irradiation, using quantitative histology and immunohistochemistry, morphometry, and real-time fluorogenic probe RT-PCR. Irradiated intestine exhibited significant histopathologic injury, reduced mucosal surface area, vascular ...

2002-01-01

221

The pisa experiment: spallation products identified by bragg curve spectroscopy  

International Nuclear Information System (INIS)

In the framework of spallation neutron sources and accelerator-driven systems, the international PISA (Proton-induced Spallation) collaboration has initiated measurements of total- and double-differential cross-sections for products of spallation reactions in a wide range of target nuclei (GU) at the COSY proton accelerator in Julich (Germany). The purpose is to study secondary particle production created in structural, window and target materials via proton beams up to 2.5 GeV of incident kinetic energy. Residual nuclei [H, He up to intermediate mass fragment (IMF)] production cross-sections are of great importance for estimating the damage to target and structure materials involving the planned spallation neutron sources, given that the lifetime of window and target materials is directly associated to those cross-sections. The demand for reliable theoretical predictions on production cross-sections is by no means satisfied by the models and ...

2004-05-17

222

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, ...

1979-01-01

223

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

224

High order statistical signatures from source-driven measurements of subcritical fissile systems  

Energy Technology Data Exchange (ETDEWEB)

This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of significant utility ...

1998-04-01

225

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is ...

1988-10-01

226

Characterisation of polynuclear aromatic sulfur-heterocycles in a coal extract by GC/MS  

Energy Technology Data Exchange (ETDEWEB)

Polynuclear aromatic sulphur heterocycles (PASHs) were isolated from a coal extract by two-step separation method using silica gel column chromatography and ligand exchanges thin layer chromatography (PdCl{sub 2}/SiO{sub 2}). The subfraction was examined by capillary column gas chromatography with flame ionization detector and flame photometric detector and gas chromatography - mass spectrometry. Identification was accomplished by comparison of chromatographic retention indices and mass spectra of compounds with those reported in the literature. It was found that the principal structures of the sulphur-containing fraction of Guiding coal extract have 3-4 aromatic rings. Dibenzothiophene, C{sub 1} - C{sub 3} alkylated dibenzothiophenes, benzonaphthothiophene and its alkylated derivatives were the main compounds. Only a few other polynuclear sulfur heterocycles were detected. No benzothiophene and its derivatives were ...

1994-06-01

227

Study of the physical and mechanical changes in packaging materials used in radiation processing - measuring methods of physical and mechanical properties  

International Nuclear Information System (INIS)

The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline ...

228

The MiniBooNE detector technical design report  

Energy Technology Data Exchange (ETDEWEB)

The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation parameters as shown in ...

2003-04-18

229

Study of radiation chemistry in solids using solid hydrogen  

Energy Technology Data Exchange (ETDEWEB)

Having simple and highly symmetric structure, solid hydrogen is a useful matrix on the study of radiation-chemical processes in solid phase which have been less understood in previous studies. We have found three outstanding findings: resonance effects on the tunneling reaction H+H{sub 2} {yields} H{sub 2} + H, effects of pressure on the dissociation and recombination of H{sub 2} molecules in solid hydrogen, and high-resolution ESR spectroscopy using a solid parahydrogen matrix. (author)

2002-03-01

230

Radiolysis of neutron irradiated lithium solutions  

International Nuclear Information System (INIS)

In the Aqueous Self-Cooled Blanket (ASCB) concept, an aqueous "6Li solution in a metallic structure is used as a shielding-breeding blanket for fusion reactors. The experimental results of this study indicate that the radiolytic gas production in an ASCB will be proportional to the absorbed radiation energy. The observed radiation chemical yields allow the preliminary estimation of the radiolysis effects for a specific ASCB design. Contrary to the theoretical predictions, the use of hydrogen as a cover gas at up to 1 MPa had no measurable effect on the radiolytic gas production. Probably it will thus not be possible to suppress the radiolytic decomposition of a low-pressure ASCB by the addition of hydrogen. Catalytic recombination will be required. (orig.).

231

Radiation induced synthesis of low molecular weight of PTFE and their crosslinking in acetone medium  

International Nuclear Information System (INIS)

Polytetrafluoroethylene was obtained by radiation induced polymerization of tetrafluoroethylene in acetone at 195 K. An average diameter of the products was very small compared with commercial one; it was about 0.3 micro-meters. The yield was reached to 100% with a dose of 4 kGy. The crystallinity of the products is decreasing with increasing dose. The products become amorphous, for higher irradiation doses. It was found that PTFE obtained by irradiation of TFE in acetone at 195 K has branching structure. This was demonstrated by means of "1"9F MAS NMR. (Author)

2007-09-03

232

Free radicals and their transformations in irradiated proteins  

International Nuclear Information System (INIS)

Experimental investigation data are systematized of free radical states and processes in irradiated proteins. The investigation is performed by the radiospectral methods. Results are discussed in detail of the study of free radicals electronic structure of amino acids, peptides and proteins formed by the action of ionizing radiation. The specificity is stressed of the study of monocrystalls of these compounds by the method of electronic paramagnetic resonance. The nature is also studied of primary centres formed under the effect of radiation on biologically important compounds and their subsequent reactions in solid and liquid solutions. Ion-radical states of different functional groups of the protein molecule are studied. Prospects of the study and the role of anion-radicals in biological processes are discusses.

233

Application of multi-stage, multi-disk type downhole seismic source; Tadanshiki taso enbangata koseinai shingen no tekiyosei  

Energy Technology Data Exchange (ETDEWEB)

A multi-stage, multi-disk type seismic source was developed as a downhole seismic source. The seismic source is an improved version of the downhole seismic source of a system in which an elastic wave is generated by a weight accelerated by restitutive force of a spring striking the upper part of a laminated structure consisted of metal disks and elastic bodies installed in water in a well. Enhancing the vibration exciting efficiency requires impedance radiated from the disks to be increased. The multi-disk structure was adopted because of restrictions on the disk area under the limiting condition of being inside the well. Further limitation has still existed, which led to finally structuring the multi-disk type to a multi-stage construction to increase the radiated impedance. In order to increase average velocity on the radiation surface, mass relationship ...

1997-05-27

234

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from ...

2006-07-01

235

Radiation factors specifying safety in reactor compartments handling in the process of decommissioning nuclear-powered submarines  

International Nuclear Information System (INIS)

The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and ...

1996-03-10

236

Immobilization of stationary phases onto chromatographic supports by gamma radiation  

International Nuclear Information System (INIS)

Cobalt-60 gamma radiation has been found to be an effective means of immobilizing stationary phases onto gas and liquid chromatographic supports. The ability of a phase to crosslink was determined to be highly dependent on its chemical structure. Gamma radiation was employed to immobilize Se-30, a methylsilicone, and 216 PS onto Chromosorb WHP for packed column chromatography. The resultant columns exhibited increased thermal stability and a high degree of efficiency. Several blended phases containing varying ratios of Se-30:216 PS were also immobilized onto chromatographic packings. This work was further extended to the immobilization of Se-30 and 216 PS onto fused silica capillaries via gamma radiation. Columns exhibited excellent efficiency and improved thermal stability. An investigation into the role of immobilization of polymeric phases for HPLC was undertaken. Results indicate that gamma ...

237

Direct Stellar Radiation Pressure at the Dust Sublimation Front in Massive Star Formation: Effects of a Dust-free Disk  

Science.gov (United States)

In massive star formation (gsim 40 M sun) by core accretion, the direct stellar radiation pressure acting on the dust particles exceeds the gravitational force and interferes with mass accretion at the dust sublimation front, the first absorption site. Ram pressure generated by high accretion rates of 10-3 M sun yr-1 is thought to be required to overcome the direct stellar radiation pressure. We investigate the direct stellar irradiation on the dust sublimation front, including the inner accretion disk structure. We show that the ram pressure of the accretion disk is lower than the stellar radiation pressure at the dust sublimation front. Thus, another mechanism must overcome the direct stellar radiation pressure. We suggest that the inner hot dust-free region is optically thick, shielding the dust sublimation front from direct stellar irradiation. Thus, accretion would not halt at ...

2011-10-01

238

Surface segregation and radiation hardening of 16Cr12MoWSiVNbB steel after irradiation with Ni++ and He+ ions  

British Library Electronic Table of Contents (United Kingdom)

Irradiation of EP-823 (16Cr12MoWsiVNbB) ferritic-martensitic steel with 7-MeV Ni++ ions and with 30- and 70-keV He+ ions at a temperature of 500?C was followed by an increase in the microhardness, which was due to both radiation point defects and changes in the phase composition and the dislocation structure of the steel. It was found that the dependence of the largest relative increase in the microhardness on the concentration of radiation-induced point defects in the near-surface region of the steel under irradiation with different ions correlated with an analogous dependence of the surface segregation of silicon and chromium.

2011-01-01

239

Preparation and applications of wood-polyester composites  

International Nuclear Information System (INIS)

Optimum processing parameters were searched for the pilot-scale production of wood-polyester composites by irradiation of resin-impregnated wood material. The radiation initiation of the following systems were examined in wood and without wood matrix: methyl methacrylate, mixture of styrene and acrylonitryle, and their combination with unsaturated polyester. In the most cases the over-all rate of the complete polymerization process in wood matrix is proportional to the square root of the initiation rate. The parameters of the radiation technology of wood-polyester composites have been determined, using 260 TBq (7 kCi) "6"0Co radiation source. A pilot plant has been constructed using an underwater irradiation system of 1.85 PBq (50 kCi) "6"0Co. The successful production rate of 200 kg wood-polyester composite per day, as well as the application tests have demonstrated the technical feasibility of this new ...

1982-01-01

240

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

241

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...

1984-10-01

242

Chemistry and technology of radiation processed composite materials  

International Nuclear Information System (INIS)

Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for ...

1984-10-01

243

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

British Library Electronic Table of Contents (United Kingdom)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200?mm and 300?mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of ...

2008-01-01

244

Ammonium azide: a commented example of an Ab initio structure (Re-) determination from X-ray powder diffraction  

Energy Technology Data Exchange (ETDEWEB)

The structure of ammonium azide (NH{sub 4})N{sub 3} was (re-)determined ab initio from x-ray powder diffraction experiment using synchrotron radiation. We tried to detail and comment the different steps involved in the structure determination. The compound crystallize in the orthorhombic Pmna space group (no.53) with a = 8.937(1) A, b= 3.8070(5) A, c = 8.664(1) A, V = 294.79(7) A{sup 3}; Z= 4. It was possible to locate and refine the hydrogen coordinates, in two different approaches, and to establish the H-bonds. The final structural parameters are in good agreement with previous results based on three-dimensional neutron diffraction. (Author)

2002-07-01

245

Ammonium azide: a commented example of an Ab initio structure (Re-) determination from X-ray powder diffraction  

International Nuclear Information System (INIS)

The structure of ammonium azide (NH_4)N_3 was (re-)determined ab initio from x-ray powder diffraction experiment using synchrotron radiation. We tried to detail and comment the different steps involved in the structure determination. The compound crystallize in the orthorhombic Pmna space group (no.53) with a = 8.937(1) A, b= 3.8070(5) A, c = 8.664(1) A, V = 294.79(7) A"3; Z= 4. It was possible to locate and refine the hydrogen coordinates, in two different approaches, and to establish the H-bonds. The final structural parameters are in good agreement with previous results based on three-dimensional neutron diffraction. (Author)

246

Radiation tolerant GaAs MESFET with a highly-doped thin active layer grown by OMVPE  

International Nuclear Information System (INIS)

A new structure of GaAs MESFET with high radiation tolerance is proposed. Changes in electrical parameters of a GaAs MESFET as a function of total #gamma#-ray dose have been found to be caused mainly by a decrease in the effective carrier concentration in an active layer. The authors have designed a new structure from a simulation based on an empirical relationship between the changes of the effective carrier concentration and the total #gamma#-ray dose. It has been successfully demonstrated by utilizing a highly-doped thin active layer (4 x 10"1"8 cm"-"3, 100 Angstrom) grown by OMVPE. This MESFET can withstand a dose ten times higher [1 x 10"9 rads(GaAs)] than a conventional one can.

1990-07-16

247

Irradiation of polyethylene in the presence of antioxidants  

International Nuclear Information System (INIS)

The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbed doses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).

248

Degredation of superconductive properties in type A 15 compounds after irradiation  

International Nuclear Information System (INIS)

The influence of irradiation with 2.6 MeV H and He nuclei on the superconducting properties (critical temperature Tsub(c), critical current Isub(c)) of the intermetallic compound Nb_3Sn was studied. Irradiation led to a significant lowering of Tsub(c), while Isub(c) is increasing with the radiation dose. This is assumed to be due to the formation of active pinning centres in the lattice. There is a fast drop of Isub(c) after a peak value has been reached. Annealing of the samples (600-1,000"0C) led to an almost complete recovery of the initial value of Tsub(c). X-ray diffraction showed that irradiation causes considerable distortions of the lattice while the A15 crystal structure is retained. The causes of the radiation effects related to structural defects are discussed. (GSCH).

249

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

250

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

251

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport ...

2009-12-01

252

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...

253

Total interaction cross sections and effective atomic numbers of some biologically important compounds containing H, C, N and O in the energy range 6.4-136 keV  

International Nuclear Information System (INIS)

The total interaction cross sections (#sigma#_t) of some sugars and amino acids and five elements: lithium, carbon, oxygen, aluminium and calcium have been measured for 6.4 keV, 13.95 keV, 14.4 keV, 17.74 keV, 24.14 keV, 30.8 keV, 35 keV, 59.54 keV, 81 keV, 122 keV and 136 keV photons in a narrow beam good geometry set up, by using high resolution detectors such as a Si-PIN diode detector and a high purity germanium detector. The #sigma#_t values have been used in a matrix method to evaluate the effective atomic numbers Z_e_f_f of the samples from their effective atomic cross sections #sigma#_a. The effective atomic cross section of a sample #sigma#_a is the total interaction cross section divided by the total number of atoms of all types in it. Further, a quantity called the effective atomic weight A_e_f_f of a sample was defined as the ratio of the molecular weight A to the total number of atoms of all types in it. The ...

2007-09-28

254

Rocket borne solar eclipse experiment to measure the temperature structure of the solar corona via lyman-. cap alpha. line profile observations  

Energy Technology Data Exchange (ETDEWEB)

A rocket borne experiment to measure the temperature structure of the inner solar corona via the doppler broadening of the resonance hydrogen Lyman-..cap alpha.. (lambda1216A) radiation scattered by ambient neutral hydrogen atoms was attempted during the 16 Feb 1980 solar eclipse. Two Nike-Black Brant V sounding rockets carrying instrumented payloads were launched into the path of the advancing eclipse umbra from the San Marco satellite launch platform 3 miles off the east coast of Kenya.

1981-01-01

255

The kinematics of coronal mass ejections using multiscale methods  

CERN Document Server

The diffuse morphology and transient nature of coronal mass ejections (CMEs) make them difficult to identify and track using traditional image processing techniques. We apply multiscale methods to enhance the visibility of the faint CME front. This enables an ellipse characterisation to objectively study the changing morphology and kinematics of a sample of events imaged by the Large Angle Spectrometric Coronagraph (LASCO) onboard the Solar and Heliospheric Observatory (SOHO) and the Sun Earth Connection Coronal and Heliospheric Investigation (SECCHI) onboard the Solar Terrestrial Relations Observatory (STEREO). The accuracy of these methods allows us to test the CMEs for non-constant acceleration and expansion. We exploit the multiscale nature of CMEs to extract structure with a multiscale decomposition, akin to a Canny edge detector. Spatio-temporal filtering highlights the CME front as it propagates in time. We apply an ellipse ...

2009-01-01

256

Spin polarisation and anomalous Hall effect in NiMnSb films  

International Nuclear Information System (INIS)

NiMnSb has attracted a great deal of interest as a spin injector/detector in spintronic devices because it has a Curie temperature of 728 K and is predicted to be half-metallic (100% spin polarized). NiMnSb has been reported to have greatly reduced surface polarization, and to lose its half metallicity above 80 K. Here we report the investigation of the surface polarisation and electronic structure of NiMnSb by measurement of the transport spin polarization using point contact Andreev reflection spectroscopy, and anomalous Hall effect in thin films on Si(0 0 1). A comparison to bulk properties is made.

2004-05-01

257

Search for Z' ---> e+ e- using dielectron mass and angular distribution  

Energy Technology Data Exchange (ETDEWEB)

The authors search Z{prime} bosons in dielectron events produced in p{bar p} collisions at {radical}s = 1.96 TeV, using a 0.45 fb{sup -1} dataset accumulated with the CDF II detector at the Fermilab Tevatron. To identify the Z{prime} {yields} e{sup +}e{sup -} signal, both the dielectron invariant mass distribution and the angular distribution of the electron pair are used. No evidence of a signal is found, and 95% confidence level lower limits are set on the Z{prime} mass for several models. Limits are also placed on the mass and gauge coupling of a generic Z{prime}, as well as on the contact interaction mass scales for different helicity structure scenarios.

2006-02-01

258

Radon as a tracer of fluids motion in karstic aquifers; Le radon: traceur des circulations fluides dans les aquiferes karstiques  

Energy Technology Data Exchange (ETDEWEB)

Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.

1995-04-01

259

Method of feeding a coolant into a reactor  

International Nuclear Information System (INIS)

Object: To suppress a quantity of impurities in a coolant fed into a reactor vessel. Structure: The concentration of oxygen in a coolant flowing from a condensation desalting instrument into a feed and condensation piping is measured by an oxygen-concentration detector to feed its signal to an adjusting instrument. A degree of opening of an oxygen flow control valve to maintain the concentration of oxygen in the cooling water flowing within the pipe in the range from about 10 to about 200 ppb. Also, the concentration of oxygen in the cooling water fed to the desalting instrument is maintained at a level less than 2 ppb. Thereby, the total amount of iron flown into the vessel can be suppressed to a fine amount such as less than about 1 ppb. (Kawakami, Y.).

260

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

261

First observation of excited states in the T_z=1/2 nucleus "8"5Mo  

International Nuclear Information System (INIS)

Excited states in the T_z=(1/2) nucleus "8"5Mo have been observed for the first time with the reaction "5"8Ni("3"2S,#alpha#n#gamma#) at 105 MeV. #gamma#-ray transitions in this nucleus have been assigned unambiguously by combining the information from the GASP #gamma#-ray array, the ISIS silicon ball, and the n-Ring neutron detector. Two band structures have been observed in this nucleus; they continue the smooth evolution of the known bands from the lighter N=43 isotones and have been tentatively assigned spins and parity on this basis. After reaching a maximum of collectivity at "8"3Zr, the trend with increasing mass is reversed, showing a smaller collectivity at "8"5Mo. The rotational behavior of the observed bands is discussed on the basis of the projected shell model calculations.

2002-03-01

262

Decays of "8"8Kr and "8"8Rb  

International Nuclear Information System (INIS)

The #gamma# rays following the #beta# decays of "8"8Kr and "8"8Rb have been studied, using both large volume Ge(Li) detectors for singles and coincidence measurements and anti-Compton spectrometry for singles measurements. Level schemes for "8"8Rb and "8"8Sr were constructed from the data and 74 of 81 #gamma# rays observed in the decay of "8"8Kr were placed in the "8"8Rb level scheme with 23 excited states. For the decay of "8"8Rb, all of the observed 27 #gamma# rays have been placed in the (well known) level structure of "8"8Sr. Spin and parity assignments have been deduced from #beta#-decay logft values and #gamma#-ray transition patterns. Possible shell model interpretations are presented for the level schemes.

263

Crystallization and preliminary X-ray studies of a galactose-specific lectin from the seeds of Spatholobus parviflorus  

British Library Electronic Table of Contents (United Kingdom)

A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.

2011-01-01

264

Beam extraction studies at 900 GeV using a channeling crystal  

CERN Document Server

Luminosity-driven channeling extraction has been observed for the first time in a 900 GeV study at the Fermilab Tevatron. This experiment, Fermilab E853, demonstrated that useful TeV level beams can be extracted from a superconducting accelerator during high luminosity collider operations without unduly affecting the background at the collider detectors. Multi-turn extraction was found to increase significantly the efficiency of the process. The beam extraction efficiency was about 25%. Studies of time dependent effects found that the turn-to-turn structure was governed mainly by accelerator beam dynamics. An investigation of a pre-scatterer using the accelerator flying wire system showed that a fiber could produce a significant extracted flux, consistent with expectations. Based on these results, it is feasible to construct a parasitic 5-10 MHz proton beam from the Tevatron collider.

1999-01-01

265

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

266

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

267

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

268

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

269

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

270

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

271
272

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

273

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

274

Multi-channel algebraic scattering theory and the structure of exotic compound nuclei  

CERN Document Server

A Multi-Channel Algebraic Scattering (MCAS) theory is presented with which the properties of a compound nucleus are found from a coupled-channel problem. The method defines both the bound states and resonances of the compound nucleus, even if the compound nucleus is particle unstable. All resonances of the system are found no matter how weak and/or narrow. Spectra of mass-7 nuclei and of {}^{15}F, and MCAS results for a radiative capture cross section are presented.

2007-01-01

275

Electron linear accelerators for radiotherapy  

International Nuclear Information System (INIS)

Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.

1983-06-01

276

Calculation of atomic spontaneous emission rate in 1D finite photonic crystal with defects  

CERN Document Server

We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.

2009-01-01

277

Biophysical effect of microwave radiation. Biofizicheskoe deistvie SVCh-izluchenii  

Energy Technology Data Exchange (ETDEWEB)

The physical principals of the interaction between microwaves and matter are considered along with the physical-chemical mechanisms for the absorption of microwave energy by biological tissue. Consideration is given to results of studies of the effects of microwaves on cells, subcellular structures, and membranes. Medical applications of microwaves are discussed along with the development of health standards for the use of microwaves. 122 references.

1987-01-01

278

Study on laminar burning velocity of premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames; CH{sub 4}/O{sub 2}/CO{sub 2} yokongo kaen no soryu nensho sokudo ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

Experimental and numerical investigations were performed for the laminar burning velocity and the flame structure of laminar premixed CH{sub 4}/O{sub 2}/CO{sub 2} flames. Measurements of the laminar burning velocity were conducted by using a flame cone angle method for a circular nozzle burner. Numerical simulation was performed using one-dimensional plane flame code including radiation heat loss with an optically thin model. It was shown that the laminar burning velocity decrease with CO{sub 2} addition even though the adiabatic flame temperature is the same as that for CH{sub 4}/Air flames. The radiation heat loss is significant for the CH{sub 4}/O{sub 2}/CO{sub 2}, flames, and the flame temperature and laminar burning velocity decreases when the radiation heat loss is considered. Effects of thermal properties, radiation, and chemical reaction on the determination of the laminar ...

1999-07-25

279

Radiation hardening of diagnostics  

International Nuclear Information System (INIS)

The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for ...

280

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that allows to detect variations of porosity and grain size as well as cracks and voids when ...

1995-08-01

281

Gamma radiation (Co{sup 60}) effects on active substances and microbe burden of medicinal plants; Avaliacao dos efeitos da radiacao gama (Co{sup 60}) sobre principios ativos e carga microbiana de plantas medicinais  

Energy Technology Data Exchange (ETDEWEB)

In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co{sup 60}). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific ...

2001-04-01

282

Effect of irradiation on bone remodelling and the structural integrity of the vertebral column. Doctoral thesis  

Energy Technology Data Exchange (ETDEWEB)

The effects of therapeutic levels of radiation on the axial properties of the primate vertebral column were studied. Seven male rhesus monkeys (Macaca mulatta) were irradiated with a single does of 1300 cGy to the specific lumbar vertebrae of L2, L3, and L4. Three additional animals served as controls. Radiographs were taken before the radiation treatment and just prior to sacrifice to determine density changes in the bone. The animal subjects were sacrificed 105 days following the radiation exposure. Biomechanical testing was completed on lumbar levels 2 and 3 to identify changes in strength characteristics following radiation treatment. Histomorphometric analysis of lumbar vertebrae level 4 was completed to identify volume and surface density changes as well as cellular changes. Tetracycline, dicarbomethylaminomethyl fluorescein (DCAF), and xylenol orange were used as bone labeling agents to aid in ...

1990-01-01

283

Chromosomal study in lymphocytes from subjects living or working in buildings constructed with radioactively contaminated rebar  

Energy Technology Data Exchange (ETDEWEB)

It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or ...

1997-07-03

284

Chromosomal study in lymphocytes from subjects living or working in buildings constructed with radioactively contaminated rebar  

International Nuclear Information System (INIS)

It has recently been found that many buildings in Taiwan were constructed with radioactively contaminated rebar, which raised great concern among the residents as well as governmental officials. In order to investigate the possible cytogenetic damage to the residents of contaminated buildings, a G-banding method was carried out on the lymphocytes of 30 radiation-exposed individuals from four families and one office building, as well as 15 control individuals from laboratory personnel. The estimated cumulative radiation doses for the exposed people range from 19.63 to 280.50 mSv. Altogether, 13 females and 17 males belonging to the radiation-exposed group, and 7 females and 8 males in the control group, were included in this study. With the exception of one sample, at least 500 metaphase spreads were scored and analyzed for each individual. All the recognizable structural aberrations of chromosomes or ...

285

Structure analysis of cation selective Cr-goethite as protective rust of weathering steel  

International Nuclear Information System (INIS)

We have performed extended X-ray absorption fine structure (EXAFS) analysis for artificial Cr-goethite to elucidate the local structure around Cr in Cr-goethite. The spectra were obtained using synchrotron radiation X-rays at the Photon Factory in Tsukuba. The first shell contributions were isolated by Fourier filtering EXAFS data, and the inverse Fourier transformed single-shell data were analyzed using a curve fitting method. The results show that Cr is coordinated with (7#+-#1)O"2"- ions. The protective characteristics of the Cr-goethite protective rust layer on weathering steel can be interpreted in terms of the O"2"- coordination around Cr"3"+ resulting in the creation of negative fixed charge in the Cr-goethite particles. (author)

2005-02-01

286

Spatially resolved methane band photometry of Jupiter. III - Cloud vertical structures for several axisymmetric bands and the Great Red Spot  

Energy Technology Data Exchange (ETDEWEB)

The paper presents cloud structure models for Jupiter's Great Red Spot, Equatorial and North Tropical Zones, North and South Temperate Zones, and North and South Polar Regions. The models are based on images of Jupiter in three methane bands and nearby continuum radiative transfer calculations include multiple scattering and absorption from three aerosol layers. The model results include the transition in the upper-cloud altitude to 3 km lower altitude from the tropical zones to temperate zones and polar regions, a N/S asymmetry in cloud thickness in the tropical and temperature zones, and the presence of aerosols up to about 0.3 bar in the Great Red Spot and Equatorial Zone. It is concluded that polarization data are sensitive to aerosols in and above the upper cloud layer but insensitive to deeper cloud structure.

1980-02-01

287

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the present work is the evaluation of the gamma ...

2007-11-05

288

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations ...

1983-01-01

289

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using ...

1983-01-01

290

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a ...

1983-01-01

291

A search for. nu. sub e appearance from stopped. pi. sup + and. mu. sup + decay at LAMPF (Los Alamos Meson Physics Facility)  

Energy Technology Data Exchange (ETDEWEB)

We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the ...

1990-01-01

292

Observation of two charged bottomonium-like resonances  

CERN Document Server

We report the observation of two narrow structures at 10610MeV/c^2 and 10650MeV/c^2 in the pi^{\\pm}Upsilon(nS) (n=1,2,3) and pi^{\\pm}h_b(mP) (m=1,2) mass spectra that are produced in association with a single charged pion in Upsilon(5S) decays. The measured masses and widths of the two structures averaged over the five final states are M_1=10608.4\\pm2.0MeV/c^2, Gamma_1=15.6\\pm2.5MeV and M_2=10653.2\\pm1.5MeV/c^2, Gamma_2=14.4\\pm3.2MeV. Analysis favors quantum numbers of I^G(J^P)=1^+(1^+) for both states. The results are obtained with a 121.4fb^{-1} data sample collected with the Belle detector near the Upsilon(5S) resonance, at the KEKB asymmetric-energy e+e- collider.

2011-01-01

293

High resolution alpha-particle spectroscopy using CR-39 plastic track detector  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural decay energy and from alpha-particles ...

1984-06-15

294

Recent progress of the JAERI free electron laser driven by a compact superconducting RF linac  

International Nuclear Information System (INIS)

A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and distance measurement system has been newly developed, and successfully applied to ...

1997-02-28

295

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

296

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

297

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

298

Study of e{sup +}e{sup -}{yields}pp using initial state radiation with BABAR  

Science.gov (United States)

The e{sup +}e{sup -}{yields}pp cross section is determined over a range of pp masses, from threshold to 4.5 GeV/c{sup 2}, by studying the e{sup +}e{sup -}{yields}pp{gamma} process. The data set corresponds to an integrated luminosity of 232 fb{sup -1}, collected with the BABAR detector at the PEP-II storage ring, at an e{sup +}e{sup -} center-of-mass energy of 10.6 GeV. The mass dependence of the ratio of electric and magnetic form factors, G{sub E}/G{sub M}, is measured for pp masses below 3 GeV/c{sup 2}; its value is found to be significantly larger than 1 for masses up to 2.2 GeV/c{sup 2}. We also measure J/{psi}{yields}pp and {psi}(2S){yields}pp branching fractions and set an upper limit on Y(4260){yields}pp production and decay.

2006-01-01

299

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

300

Radiometric analysis of raw materials and end products in the Turkish ceramics industry  

International Nuclear Information System (INIS)

This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. The results suggest ...

2011-05-01

301

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...

2007-04-01

302

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

303

Muon trigger, flavour tagging and physics performance of the LHCb experiment; Trigger a muons, etiquetage de la saveur et performances physiques de l'experience LHCb  

Energy Technology Data Exchange (ETDEWEB)

The LHCb experiment that is being settled in CERN is dedicated to the study of CP violation and rare decays in the field of beauty hadrons. The phenomenological background necessary to an adequate understanding of the physics of flavor is presented in the first chapter, it is shown how the flavordynamics can open the way to new physics. The second chapter is dedicated to a brief presentation of the LHCb detector. Two aspects of the design of the muon trigger are more detailed: the radiation resistance of the opto-electronic transmitters and the simulated performances of the trigger. The third chapter reviews the tasks linked to the tagging of the savors of B mesons which will be an important step in all the experiments made at LHCb. The recent progress in heavy savor physics as well as the expected contribution of LHCb in this field are presented in the fourth chapter, especially the search for new physics in penguin diagrams b {yields} s.

2007-10-15

304

Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction  

International Nuclear Information System (INIS)

The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.

1981-07-01

305

Coated semiconductor devices for neutron detection  

Energy Technology Data Exchange (ETDEWEB)

A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and electrical settings, neutrons at specific ...

2002-01-01

306

An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...

1990-09-16

307

Acceptance testing in digital systems of mammography. Protocols applicability  

International Nuclear Information System (INIS)

Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure control compensation and ...

308

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...

2000-03-21

309

The crystal structure of the novel ternary silicide Sm_4Pd_4Si_3  

International Nuclear Information System (INIS)

The crystal structure of the compound Sm_4Pd_4Si_3 was determined by the single-crystal method (KM-4 automatic diffractometer, Mo K#alpha# radiation). Sm_4Pd_4Si_3 has the monoclinic Nd_4Rh_4Ge_3 type structure: space group C2/c, mC44 (No. 15), a=20.693(6), b=5.584(1), c=7.699(2) A, #beta#=109.48(3) , V=838 A"3, Z=4, #mu#=36.23 mm"-"1, R_F=0.0537, R_W=0.0435 for 1652 unique reflections. The coordination numbers of samarium atoms are 17 and 18. For palladium and silicon atoms icosahedra and trigonal prisms with additional atoms are typical as coordination polyhedra. The structure of Sm_4Pd_4Si_3 is composed of fragments of the YPd_2Si and Y_3Rh_2Si_2 structure in a ratio 1:1. (orig.).

310

Structural transformations in Sc/Si multilayers irradiated by EUVlasers  

Energy Technology Data Exchange (ETDEWEB)

Multilayer mirrors for the extreme ultraviolet (EUV) are keyelements for numerous applications of coherent EUV sources such as newtabletop lasers and free-electron lasers. However the field ofapplications is limited by the radiation and thermal stability of themultilayers. Taking into account the growing power of EUV sources thestability of the optics becomes crucial. To overcome this problem it isnecessary to study the degradation of multilayers and try to increasetheir temporal and thermal stability. In this paper we report the resultsof detailed study of structural changes in Sc/Simultilayers when exposedto intense EUV laser pulses. Various types of surface damage such asmelting, boiling, shockwave creation and ablation were observed asirradiation fluencies increase. Cross-sectional TEM study revealed thatthe layer structure was completely destroyed in the upper part ofmultilayer, but still survived below. The layers ...

2007-08-21

311

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

315

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

316

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

317

Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22[sup o]C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm[sup -1] (amide I), 1200-1300 cm[sup -1] (amide III) and 550-1030 cm[sup -1] (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm[sup -1] are tyrosines and cysteines. The radiation-induced changes in the secondary ...

1993-03-01

318

Ionizing radiation target groups of band 3 inserted into egg lecithin liposomes as determined by Raman spectroscopy  

International Nuclear Information System (INIS)

The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22"oC. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm"-"1 (amide I), 1200-1300 cm"-"1 (amide III) and 550-1030 cm"-"1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm"-"1 are tyrosines and cysteines. The radiation-induced changes in the secondary ...

319

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...

2011-02-01

320

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

321

Valence mixing in rare earth compounds  

International Nuclear Information System (INIS)

The concepts of ''fast'' and ''slow'' time scale valence measurements are emphasized by a comparison of L/sub III/ absorption and Mossbauer effect measurements on the temperature induced valence change in EuPd/sub 2/Si/sub 2/. Further the authors show how synchrotron radiation based L/sub III/ measurements of the Ce-valence state can be used to demonstrate electronic structure trends under wide changes in chemical environment. The purpose of this paper is to provide an introduction to researchers in the People's Republic of China to the field of mixed valent rate earth compounds. They hope to illustrate some of the basic concepts in this field, how the field is contributing to the overall insight into the chemical physics of solids and finally how synchrotron radiation measurements in particular are playing a key role in this field.

322

Laser-Cooling of Liquid Water by the Ar-Xe Laser Radiation  

CERN Document Server

An effect of laser-cooling of water was observed for the first time with a temperature decrease dT = -2.2 K after irradiation of liquid water surface by a powerful Ar-Xe pulse laser with a pulse energy of about 1 J and wavelength L = 1.73, 2.63 and 2.65 um. The discovered effect can apparently be ascribed to the optical excitation of vibrational states of H2O molecules followed by an endothermic consolidation of chemically active excited molecules into a quasi-stable cluster-like structure. The measured time dependences of the cooling effect show that a typical life time of the new state of water amounts to hours. It has also been shown that the life time of the excited vibrational molecular states due to a radiation trapping effect can be estimated to at least hundreds of seconds.

2010-01-01

323

Ion-radiation hardening of magnesium oxide crystals  

International Nuclear Information System (INIS)

Consideration is given to the data, demonstrating the effect of ion radiation on strength characteristics of ionic crystals, presented by magnesium oxide. Crystals, prepared in the form of plates, were irradiated by Si"+, Fe"+, C"+ ions by the dose of 10"1"6-10"1"7 ion/cm"2 at room temperature in vacuum. The following characteristics were investigated: dislocation density, microhardness, crack resistance. Investigation of dislocation structure showed, that dislocation density in irradiated sample was 2-3 times higher, as compared to nonirradiated one. Sufficient increase of fracture viscosity of MgO crystals was revealed. It can be conditioned by occurrence of compression stresses in the surface layer, decelerating crack formation and propagation.

324

Investigation of changes in hyperfine interaction and Debye-Waller-factor by #alpha#-radiation self damage in "2"4"1Am metal  

International Nuclear Information System (INIS)

The Moessbauer emission spectrum of "2"4"1Am metal was investigated for influences of radiation self damage. Samples were kept continuously for 230 h at 4.2 K and spectra were taken each 10 to 20 h. No change in f-factor was observed, while the linewidth increased monotonically and reached saturation after approximately 180 h. The original width could be reproduced by a brief warming to room temperature. The increase in width reflects the change in quadrupole interaction due to the creation of lattice defects. The constancy of the f-factor indicates that the basic crystalline structure is retained.

325

Formation of metal-polymer hybrid nanostructures during radiation-induced reduction of metal ions in poly(acrylic acid)-poly(ethylenimine) complexes  

British Library Electronic Table of Contents (United Kingdom)

The formation of nanoparticles during the radiation-induced chemical reduction of silver ions, copper ions, and nickel ions in films based on poly(acrylic acid)-poly(ethylenimine) complexes are studied via electron microscopy. This approach allows preparation of composites containing nanoparticles that are randomly distributed in the polymer matrix and materials with a regular spatial distribution of nanoparticles across the film thickness and in subsurface layers. The structure of metal-polymer hybrid materials is dependent on the irradiation conditions, the type of reduced metal ions, and their initial content in polymer matrices. The ratio between the rate of nucleation and the rate of growth of nanoparticles in the matrices of interpolyelectrolyte complexes depends on the intensity of ...

2011-01-01

326

Fast neutron irradiation induced changes in the optical and thermal properties of modified polyvinyl chloride  

International Nuclear Information System (INIS)

The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 x 10"9 n/cm"2. The optical energy gap E_o_p exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure C_p showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected. (author).

1994-11-01

327

Characteristics of radiation-induced neoplastic transformation in vitro  

Energy Technology Data Exchange (ETDEWEB)

Data are presented to support the hypothesis that the initial step in the morphologic transformation of irradiated rodent (BALB/3T3) cells is a frequent cellular event involving a large fraction of the irradiated population. This process appears to involve DNA damage, but not to represent a targeted mutation in specific structural gene(s). Morphologic transformation and immortalization appear to be distinct steps in the overall process of transformation. In contradistinction to rodent cells, immortalization is a very rare event in human diploid cells which is induced at extremely low frequencies. The hypothesis is presented that immortality develops among clones of cells bearing stable chromosomal rearrangements which emerge during the proliferation of a population of radiation damaged cells.

1986-01-01

328

Analysis of thermoluminescence glow curves of minerals sphene and epidote for radiation damage studies  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence (TL) properties of sphene and epidote are of interest in studies related to their radiation damage. Natural and artificially induced TL of these minerals has, therefore, been investigated. Both minerals exhibit complex glow curves with several overlapping peaks. The Tsub(m) -Tsub(STOP) thermal cleaning procedure has revealed three peaks in the ..gamma.. ray induced glow curve of each mineral. That these peaks obey second order kinetics was indicated by the continuously slanting structure of the Tsub(m)-Tsub(STOP) curve. The TL parameters E and s have been calculated using (i) the initial rise method, and (ii) the glow-peak shape method. In general, the values of E calculated by the first method are found to be higher than those from the second. The TL curve-fitting method is also applied in order to calculate these parameters and to serve as a cross-check on the results.

1986-01-01

329

ASFIT-VARI: A practical gamma-ray transport code for MS-DOS computers  

Energy Technology Data Exchange (ETDEWEB)

The ASFIT (Anisotropic Source-Flux Iteration Technique) code was first developed in India about 1970 to solve the radiation transport equation represented in the form of coupled integral equations separating the spatial and energy-angular transmissions. The ASFIT code uses a nodal structure in the wavelength [lambda] domain in Compton units (CU) rather than in the energy domain. The ASFIT-VARI code is the latest version available from the Radiation Shielding Information Center. It incorporates variable dimensioning and has been adapted for use on MS-DOS personal computers using the Ryan-McFarland or Microsoft Version 5.0 FORTRAN compilers. While earlier versions used point cross sections (well suited for gamma-ray transport), the present version also allows multigroup cross sections for neutron and coupled neutron-gamma-ray transport.

1990-01-01

330

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

331

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

332

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

333

The Herschel revolution: unveiling the morphology of the high mass star formation sites N44 and N63 in the LMC  

CERN Document Server

We study the structure of the medium surrounding sites of high-mass star formation to determine the interrelation between the HII regions and the environment from which they were formed. The density distribution of the surroundings is key in determining how the radiation of the newly formed stars interacts with the surrounds in a way that allows it to be used as a star formation tracer. We present new Herschel/SPIRE 250, 350 and 500 mum data of LHA 120-N44 and LHA 120-N63 in the LMC. We construct average spectral energy distributions (SEDs) for annuli centered on the IR bright part of the star formation sites. The annuli cover ~10-~100 pc. We use a phenomenological dust model to fit these SEDs to derive the dust column densities, characterise the incident radiation field and the abundance of polycyclic aromatic hydrocarbon molecules. We see a factor 5 decrease in the radiation field energy density as a ...

2010-01-01

334

Radiolytic stabilization of poly(methyl methacrylate) using commercial additives; Estabilizacao radiolitica do poli(metacrilato de metila) usando aditivos comerciais  

Energy Technology Data Exchange (ETDEWEB)

Poly(methyl methacrylate), PMMA, Acrigel, a Brazilian polymer, is used in the manufacture of medical supplies sterelizable by ionizing radiation. However, when PMMA is gamma-irradiated it undergoes main chain scissions, which promote molecular degradation causing reduction in its mechanical properties. Therefore, radiolytic of PMMA is important for it to become commercially radiosterizable. In this work some commercial additives, originally used in photo-and thermo-oxidate stabilization of polymers, were tested. Only two additives, type HALS (Hindered Amine Light Stabilizer), denoted Scavenger, showed a good protective quality. The investigation of radiation-induced main scissions was carried out by viscosimetric method. The most effective additive, added to the polymer system at 0.3 w/w%, promotes a great molecular radioprotection of 93%. That means a reduction of G-value (scissions/100 eV) from 0.611 to 0.053. In addition, the glassy ...

2000-04-01

335

Prevention and Treatment of Functional and Structural Radiation Injury in the Rat Heart by Pentoxifylline and Alpha-Tocopherol  

British Library Electronic Table of Contents (United Kingdom)

Purpose Radiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of pentoxifylline (PTX) and a-tocopherol on cardiac injury in a rat model of RIHD. Methods and Materials Male Sprague-Dawley rats received fractionated local heart irradiation with a daily dose of 9 Gy for 5 days and were observed for 6 months after irradiation. Rats were treated with a combination of PTX, 100 mg/kg/day, and a-tocopherol (20 IU/kg/day) and received these compounds either from 1 week before until 6 months after irradiation or starting 3 months after irradiation, a time point at which histopathologic changes become apparent in our model of RIHD. Results Radiation-induced increases in left ventricular diastolic pressure (in mm Hg: 35 +- 6 after sham...

2008-01-01

336

Effects of gamma and electron beam irradiation on the properties of calendered cord fabrics  

Energy Technology Data Exchange (ETDEWEB)

The effects of gamma and e-beam irradiation on mechanical and structural properties of nylon 66 (Ny 66), nylon 6 (Ny 6) and poly(ethylene terephthalate) (PET) fabrics used in tyres were investigated. The untreated (greige), treated cords and calendered fabrics were irradiated at different doses. It is found that the effects of high energy irradiation on greige, treated cords and calendered fabrics are similar. No protective effect of compounds used in calendering was observed against radiation-induced oxidative degradation. The deterioration effect of gamma irradiation on mechanical properties is much higher than that of e-beam irradiation for all types of samples. Limiting viscosity numbers of both gamma and e-beam irradiated nylon 6 and nylon 66 cords were found to decrease with increasing dose. It is concluded that PET calendered fabric has higher resistance to ionizing radiation. Ny 6 and Ny 66 calendered fabrics are ...

2010-03-15

337

Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki  

International Nuclear Information System (INIS)

For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic distribution for the survivors incide a Japanese house or other ...

1980-01-01

338

Additive effects common to radiation grafting and wood plastic composite formation  

Energy Technology Data Exchange (ETDEWEB)

A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium ...

1996-08-01

339

Jacobi stability of the vacuum in the static spherically symmetric brane world models  

International Nuclear Information System (INIS)

We analyze the stability of the structure equations of the vacuum in the brane world models, by using both the linear (Lyapunov) stability analysis, and the Jacobi stability analysis, the Kosambi-Cartan-Chern theory. In the brane world models the four-dimensional effective Einstein equations acquire extra terms, called dark radiation and dark pressure, respectively, which arise from the embedding of the three-brane in the bulk. Generally, the spherically symmetric vacuum solutions of the brane gravitational field equations have properties quite distinct as compared to the standard black hole solutions of general relativity. We close the structure equations by assuming a simple linear equation of state for the dark pressure. In this case the vacuum is Jacobi stable only for a small range of values of the proportionality constant relating the dark pressure and the dark radiation. The unstable trajectories ...

2008-05-15

340

Irradiation-effects considerations for the SP-100 space reactor  

International Nuclear Information System (INIS)

The Sp-100 reactor is a lithium-cooled high-temperature fast-spectrum reactor. The fuel is UN. The cladding is fabricated from PWC-11, a Nb alloy, as are all the primary structural components. A reactor lifetime of up to ten years with an operating temperature of 1370 K is required. The accumulated fluence is expected to be 6 x10"2"2 n/cm"2. The damage, which could result in swelling or embrittlement, anneals out as fast as it occurs for the majority of the structure. This has been confirmed by earlier radiation testing. A number of components, however, are exposed to lower temperatures and the reactor design and materials selection for these components must take this into consideration. Radiation effects must also be considered for the UN fuel, bearing materials, etc. To data an instrumented experiment, MOTO 1000A, has been conducted in the FFTF reactor and as uninstrumented experiment SPM-1 in the ...

1992-03-01

341

Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro  

Energy Technology Data Exchange (ETDEWEB)

Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels ...

1990-10-01

342

Gap-junctional communication of bone marrow stromal cells is resistant to irradiation in vitro  

International Nuclear Information System (INIS)

Bone marrow is one of the most radiosensitive organs. Irradiation causes a marked decrease in the total number of hematopoietic cells in the bone marrow. The reticular meshwork structure of marrow stromal cells, however, is relatively resistant to irradiation. Unimpaired stromal cell structure has been thought to be a prerequisite for the repopulation of hematopoietic cells during recovery from the effects of irradiation. The reticular framework is maintained by cell adhesion apparatuses such as gap junctions. The in vitro radiobiologic survival values of a cloned stromal cell line, H-1/A, were studied (n = 1.8, D0 = 138 cGy). Radiation doses of up to 4000 cGy had no detectable effects on the production of colony-stimulating factor 1. H-1/A cells communicate with each other via gap junctions as determined by the sensitive dye-transfer method. Gap-junctional communication between H-1/A cells was resistant to different levels ...

343

Experimental study of the premixed combustion within the nonhomogeneous porous ceramic media  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of premixed methane-air combustion within the one-dimensional porous ceramic burners for various burner configurations is presented. The burner is nonhomogeneous because of different pore size ceramic block used in different section of the burner. Therefore, the thermophysical and transport properties are nonuniform along the burner core length. The burners are constructed of partially stabilized zirconia. The CO and NO{sub x} emissions, flame speed, and flame stability are examined and compared at lean equivalence ratios for five different burner configurations. The sandwich-structured burner has very favorable flame stabilizing characteristic due to the radiation reflecting region. While the combustion proceeds at faster rate than other burner configurations, the radiation reflecting region and the exit surface have low temperature. Thus the NO{sub x} emission can be kept at the same low ...

1996-12-01

344

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

Energy Technology Data Exchange (ETDEWEB)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the {mu}m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride ...

2008-12-15

345

Depth-profiling of vertical sidewall nanolayers on structured wafers by grazing incidence X-ray flourescence  

International Nuclear Information System (INIS)

The Physikalisch-Technische Bundesanstalt (PTB), Germany's national metrology institute, developed an alignment strategy to specify elemental depth profiling in vertical sidewall layers on structured wafers. For this purpose, PTB's irradiation chamber for 200 mm and 300 mm silicon wafers was used to combine total-reflection X-ray fluorescence (TXRF) and grazing incidence XRF (GIXRF) techniques by employing monochromatized undulator radiation of the BESSY II electron storage ring. 3-D test structures were fabricated to develop an optimal alignment strategy allowing for depth profiling in such nanolayers. The test structures consisted of silicon bars with widths/spacings either in the ?m or in the nm range. In order to be able to differentiate the sidewalls more easily from the remainder of the structures, they were provided with an additional silicon nitride layer. Four ...

2008-12-01

346

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...

347

First Observation of Radiative B^0 -> \\phi K^0 \\gamma Decays and Measurements of Their Time-Dependent CP Violation  

CERN Document Server

We report the first observation of the radiative decay B^0 -> \\phi K^0 \\gamma using a data sample of 772 x 10^6 B B-bar pairs collected at the \\Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a signal of 37+/-8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is ${\\cal B}(B^0 -> \\phi K^0 \\gamma) = (2.74\\pm 0.60 \\pm 0.32) \\times 10^{-6}$, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP violation parameters: ${\\mathcal S}_{\\phi K_S^0 \\gamma} = +0.74^{+0.72}_{-1.05} (stat)^{+0.10}_{-0.24} (syst)$ and ${\\mathcal A}_{\\phi K_S^0 \\gamma} = +0.35 +/- 0.58 (stat)^{+0.23}_{-0.10} (syst)$. Furthermore, we measure ${\\mathcal B}(B^+ -> \\phi K^+ \\gamma) = (2.48 +/- 0.30 +/- 0.24) x 10^{-6}$, ${\\mathcal A}_{CP} = -0.03 +/- ...

2011-01-01

348

ppbar enhancement in B and J/Psi decay  

CERN Document Server

The near-threshold enhancement in the ppbar invariant mass spectrum from the B^+ -> K^+ ppbar decay reported recently by the BaBar Collaboration is studied within the J\\"ulich NNbar model. We illustrate that the invariant mass dependence of the ppbar spectrum close to the threshold can be reproduced by the final state interactions. This explanation is in line with our previous analysis of the ppbar invariant mass spectrum from the J/Psi -> gamma ppbar decay measured by the BES Collaboration. We also comment on a structure found recently in the pi^+ pi^- eta' mass spectrum of the radiative J/Psi decay by the BES Collaboration. In particular we argue that one should be rather cautions in bringing this structure in connection with the enhancement found in the ppbar invariant mass spectrum or with the existence of NNbar bound states.

2006-01-01

349

Experiments on determination of damage effect ions "2"2Ne (172 MeV) on UO_2 monocrystals  

International Nuclear Information System (INIS)

Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.

350

Electronic structure, Compton profiles and optical properties of TaC and TaN  

International Nuclear Information System (INIS)

Isotropic Compton profiles of TaC and TaN have been measured for the first time, at an intermediate resolution, using 662 keV #gamma#-radiation. Energy bands, density of states and Fermi surface topology of TaC and TaN have been computed using linear combination of atomic orbitals with density functional theory and full potential linearised augmented plane wave method. Both band structure calculations predict the metallic character of TaC and TaN. The electron momentum densities calculated using various approaches of density functional theory are compared with the present measurements. On the basis of Mulliken's population, it is also seen that TaC has more covalent bonding than TaN. The optical properties computed using full potential linearised augmented plane wave method are explained in terms of intraband transitions.

2010-11-01

351

Synthesis, crystal structure and nonlinear optical property of Rb3V5O14  

International Nuclear Information System (INIS)

The new nonlinear optical crystal Rb3V5O14 has been synthesized by solid state reaction and characterized by single-crystal X-ray diffraction, IR and thermogravimetric analysis. The crystal Rb3V5O14 crystallizes in the trigonal system with space P31m (No. 157), a=b=8.7134(12) A, c=5.2807(11) A and ?=90o, ?=90o, ?=120o, Z=1, ?=3.516 g/cm3. It is a layered structure that is very flat and strongly parallel to c. The V5O14 layer structure consists of corner-linked square and triangular pyramids. The layers are separated by Rb+ ions, which fit equally well on the V5O14 layer. The Kurtz powder SHG measurement, using 1064 nm radiation, showed that the second-harmonic generation efficiency of Rb3V5O14 is about two times that of KDP. -- Graphical abstract: The new nonlinear optical crystal Rb3V5O14 has been synthesized by solid state reaction and characterized by single-crystal X-ray diffraction, IR and thermogravimetric analysis. ...

2010-12-01

352

Indoor radon dose assessment for Osijek  

Energy Technology Data Exchange (ETDEWEB)

After ten years' investigation of radon's seasonal variation at three very different locations, as well as radon concentration measurements in kindergartens, schools, air-raid shelters and cellars, systematic indoor radon measurements were undertaken in dwellings (residential buildings) of Osijek (East Croatia, 130andpuncsp; omitted000 citizens). Indoor radon was measured by means of the LR-115 SSNT detector at 48 town locations that gave an arithmetic mean of 71.6 Bq/m{sup 3}, standard deviation of 44.0 Bq/m{sup 3} and geometric mean of 60.1 Bq/m{sup 3}, for the radon concentration range from 22.7 to 185.6 Bq/m{sup 3}. Radon measurements, performed by the silicon Radhome detector, did not differ significantly. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq/m{sup 3}, was in accordance with the theoretical log-normal distribution which was shown with the {chi}{sup 2}-test. The radon ...

1999-05-01

353

Thulium-doped vanadate crystals: Growth, spectroscopy and laser performance  

British Library Electronic Table of Contents (United Kingdom)

This work is concentrated on growth, spectroscopy and laser performance of thulium-doped vanadate crystals. At the beginning the growth techniques are analyzed and then the matrix of vanadates crystal, its structure and physicochemical properties are explained together with the rare earth activators influence. Detailed spectroscopy of the thulium-doped vanadate crystals then follows. On the background of this theoretical analysis and state of the art of the subject the description of thulium vanadate lasers (especially Tm:YVO"4, Tm:GdVO"4, and Tm:LuVO"4) together with their generated output radiation characteristics are presented.

2011-01-01

354

The application of Geant4 simulation code for brachytherapy treatment  

CERN Document Server

Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

2000-01-01

355

Summary of Uranium City, Saskatchewan remedial measures for radiation reduction with special attention to vent fan theory  

International Nuclear Information System (INIS)

Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.

1980-03-12

356

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

357

Photoacoustic response to X-ray absorption in copper and brass  

Energy Technology Data Exchange (ETDEWEB)

The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).

1990-09-01

358

Nuclear reactor with external structure cooling by natural convection  

International Nuclear Information System (INIS)

The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.

359

Nuclear fuel behavior at an atomic scale: the contributions of the ab initio calculations and the synchrotron radiation; Comportement du combustible nucleaire a l'echelle atomique: les apports des calculs ab initio et du rayonnement synchrotron  

Energy Technology Data Exchange (ETDEWEB)

This paper presents fundamental researches based on the electronic structure calculations and X absorption spectroscopy, allowing the knowledge on nuclear fuels at an atomic scale. They bring a better understanding of these material behavior to accurate the macroscopic simulation. The calculation methods, the experimental techniques of validation and the ab initio calculations results are detailed. (A.L.B.)

2000-07-01

360

Neutron irradiation effect on mechanical properties of metals after preliminary hardening  

International Nuclear Information System (INIS)

Some results on mechanical property study of copper and titanium subjected to impact load and next to neutron irradiation are presented. It was shown that shock wave influence involves a substantial shape change of the stress-strain diagram and of respective mechanical characteristics. Yield- and ultimate strength were substantially increased, as well as hardness with a considerable drop of plasticity. Also a heat stability of copper and titanium specimens was studied after being treated with shock-waves and neutron radiation. Results are given of electron microscope study of titanium structure sfter explosion hardening, which caused decomposition of hydride segregations in titanium and increased dislocation density.

361

Nanostructure of Si-Ge near-surface layers produced by ion implantation and laser annealing  

International Nuclear Information System (INIS)

An annealing with the nanosecond laser light pulse is applied for crystal lattice reconstruction of a disturbed near-surface layer, which was created in semiconductor material as a result of the implantation process. Radiation with energy density higher than the threshold value causes the melting of the surface layer and than the epitaxial recrystallization from the melt on a different substrate. Structural changes occurring in the Ge implanted Si crystals after annealing with different energy densities are investigated by means of the cross-section high-resolution transmission electron microscopy. (author)

2001-09-23

362

Influence of the humidity on leakage current under accelerated aging of polymer insulating materials  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the experimental results of accelerated aging tests conducted on three different types of polymer materials. Salt fog chamber tests were used to study the surface degradation modes for all materials. The work presented here was performed using a newly constructed fog chamber system that was able to control both chamber humidity and UV radiation. The changes in the surface morphology, material structure and leakage current were examined to study the influence of environmental humidity.

1996-12-31

363

EXAFS Study of Semimetal-Semiconductor Transition of Bismuth Clusters  

International Nuclear Information System (INIS)

Extended X-ray absorption fine structure (EXAFS) measurements of bismuth clusters in the temperature range of 23 -300 K have been performed using synchrotron radiation in order to investigate the size dependent phase transition. The inter-atomic distances around 3.0 A and 3.6 A are attributed to the nearest neighbors within the layer and between layers, respectively. EXAFS functions were analysed by the curve fitting method within a symmetric distribution approximation. The nearest neighbor distance of the 0.5 nm thick films is shorter than that of the 300 nm thick films at all the temperatures, which is related to the reduction of the inter-layer correlation.

2007-02-02

364

Dipyrone-induced changes in DNA repair and other cell membrane associated processes in Escherichia coli  

Energy Technology Data Exchange (ETDEWEB)

The analgesic, dipyrone (1,phenyl-2,3-dimethyl-5-pyrazolone-4-methylamino methane sulphonate sodium), at 20 mM concentration, inhibited the rejoining of single-strand scissions in DNA of Escherichia coli B/r cells induced by 20 krad gamma-radiation. The chemical altered the cell membrane structure as evidenced from the uptake of acriflavin, the efflux of potassium ions from the bacterial cells and the inhibition of alkaline phosphatase-a cell membrane associated enzyme. (author). 18 refs., 6 figures.

1982-09-01

365

Dipyrone-induced changes in DNA repair and other cell membrane associated processes in Escherichia coli  

International Nuclear Information System (INIS)

The analgesic, dipyrone (1,phenyl-2,3-dimethyl-5-pyrazolone-4-methylamino methane sulphonate sodium), at 20 mM concentration, inhibited the rejoining of single-strand scissions in DNA of Escherichia coli B/r cells induced by 20 krad gamma-radiation. The chemical altered the cell membrane structure as evidenced from the uptake of acriflavin, the efflux of potassium ions from the bacterial cells and the inhibition of alkaline phosphatase-a cell membrane associated enzyme. (author).

366

Development of superconducting cryo-electron microscope and its applications  

International Nuclear Information System (INIS)

Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.).

1988-01-01

367

Determination of the cell and mucous distribution in the airways of the lung  

International Nuclear Information System (INIS)

Models of the human airways have played a major role in evaluating the health effects of inhaled radionuclides. While models such as those of Weibel (1963) provide data necessary for characterizing deposition of aerosol, they have not characterized the cells at risks in the airspaces. Given the advancements in techniques and study of cell cultures exposed to ionizing radiation there is a need to extrapolate between the simple structures of cell culture systems and the complex architecture of the human airways. The preliminary data in this paper provide a complete characterization of the size and number of cells in the airways and represents a significant advance in our study of the health consequences of exposure to inhaled radionuclides. 26 refs., 2 figs., 4 tabs.

1991-01-01

368

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

370
371

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

372

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

373

Cellular Sources of Transforming Growth Factor-? Isoforms in Early and Chronic Radiation Enteropathy  

Science.gov (United States)

The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural ...

1998-11-01

374

Measurement of the charge asymmetry in top-antitop quark production with the CDF II experiment  

Energy Technology Data Exchange (ETDEWEB)

The Fermi National Laboratory (Fermilab) operates the Tevatron proton-antiproton collider at a center-of-mass energy of {radical}s = 1.96 TeV, the is therefore the only collider which is today able to produce the heaviest known particle, the top quark. The top quark was discovered at the Tevatron by the CDF and D0 collaborations in 1995. At the Tevatron, most top quarks are produced via the strong interaction, whereby quark-antiquark annihilation dominates with 85%, and gluon fusion contributes with 15%. Considering next-to-leading order (NLO) contributions in the cross section of top-antitop quark production, leads to a slight positive asymmetry in the differential distribution of the production angle {alpha} of the top quarks. This asymmetry is due to the interference of certain NLO contributions. The charge asymmetry A in the cosine of {alpha} is predicted [14] to amount to 4-6%. Information about the partonic rest frame, necessary for a measurement of A in the observable cos ...

2006-12-01

375

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone convolution ...

2007-05-01

376

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array  

Science.gov (United States)

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a ...

2009-03-10

377

Radon Mapping of the Osijek Town  

International Nuclear Information System (INIS)

After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m"-"3, standard deviation of 44.0 Bq m"-"3 and geometric mean of 60.1 Bq m"-"3, for the radon concentration range from 23 to 186 Bq m"-"3. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m"-"3, was in accordance with the theoretical log-normal distribution which was shown with #chi#"2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with ...

1998-11-11

378

On important matters (fire protection) related to No. 3 plant in the Hamaoka Nuclear Power Station, Chubu Electric Power Co., Inc., No. 2 plant in the Tsuruga Power Station, Japan Atomic Power Co., and No. 2 plant in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any ...

1985-01-01

379

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be ...

2004-01-01

380

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the ...

2010-01-01

381

Measurement of unpolarized semi-inclusive pi+ electroproduction off the proton  

Science.gov (United States)

Semi-inclusive pi+ electroproduction on protons has been measured with the CLAS detector at Jefferson Lab. The measurement was performed on a liquid-hydrogen target using a 5.75 GeV electron beam. The complete five-fold differential cross sections were measured over a wide kinematic range in Q2, x, z, and pT and over the complete range of azimuthal angles, phi, enabling us to separate the different structure functions, H2+eps*H1, H3 and H4. Our measurements of H2 at low-x were found to be in fairly good agreement with pQCD calculations, suggesting a precocious factorization of the process. Indeed, the conventional f(x)*D(z) term can account for almost all of the observed cross section, even at small z. The measured xF-distributions are in qualitative agreement with high energy data, which suggests a surprising numerical similarity between the spectator diquark fragmentation in the present reaction and the anti-quark fragmentation measured in ...

2008-01-01

382

Comparison of radon exposure assessment results: {sup 210}Po surface activity on glass objects vs. contemporary air radon concentration  

Energy Technology Data Exchange (ETDEWEB)

Radon exposure assessment in case-control studies on radon and lung cancer is generally based on contemporary radon concentration measurements, which can be affected by significant changes in the building structures or in living habits. Another method to estimate the radon exposure of the subjects is the recently developed retrospective dosimetry technique based on the {sup 210}Po surface activity from glass objects. In order to compare the results obtained by the two methods, a study has been carried out in a sample of 26 dwellings in Rome, with radon concentration values ranging from 28 to 623 Bq m{sup -3}. Retrospective detectors based on CR-39 and LR 115 were exposed on 50 glass objects in bedrooms and living rooms. The correlation factor between the two sets of data, after removing six extreme values, is 0.67, which is similar to results obtained in other validation studies of similar sample size. The correlation increases to 0.83 if the ...

2003-06-01

383

Carbon felt-based bioelectrocatalytic flow-through detectors: Highly sensitive amperometric determination of H2O2 based on a direct electrochemistry of covalently modified horseradish peroxidase using cyanuric chloride as a linking agent  

British Library Electronic Table of Contents (United Kingdom)

Horseradish peroxidase (HRP) was chemically modified using cyanuric chloride (CC) as a linking agent onto a carbon felt (CF), which is a microelectrode ensemble of micro carbon fiber (>7mm, diameter) with a random three-dimensional structure. The resulting HRP-modified CF (HRP-ccCF) exhibited well-defined redox waves based on the HRP heme Fe^I^I^I/Fe^I^I redox couple at -0.23V vs. Ag/AgCl (at pH 7.0), while the HRP-adsorbed CF (HRP-CF) showed no apparent redox couple in the same potential range, indicating that the chemical modification of HRP via CC facilitated the direct electron transfer (DET) between HRP and CF. The apparent heterogeneous electron transfer rate constant ks was estimated to be 35s^-^1. Cyclic voltammetry and electrochemical impedance spectroscopy revealed that the inter...

2011-01-01

384

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, three-dimensional computer-reconstructed neutron ...

1992-03-01

385

Symmetries in nuclei near the centre of the f{sub 7/2} shell  

Energy Technology Data Exchange (ETDEWEB)

High-spin states in the mirror pair nuclei {sup 49}Cr and {sup 49}Mn and their cross-conjugate partners, the mirror pair {sup 47}V and {sup 47}Cr have been investigated using experimental {gamma}-ray spectroscopic techniques. The combination of high-efficiency EUROBALL cluster Germanium detectors and clean exit-channel gating afforded by a 31-element silicon ball used in conjunction with a 15-detector neutron wall allowed a revision and extension to the energy level schemes of all four nuclei up to J{sup {pi}}=31{sup -}/2. The difference in excitation energy between states of equivalent spin in the parent nucleus and its analogue partner have thus been established for both mirror pairs up to the f{sub 7/2}-shell band terminating state for the first time. This difference is assumed to be due almost entirely to the Coulomb effect and is therefore called the Coulomb energy difference (CED). The variation in the CED with spin has been interpreted ...

1998-10-01

386

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

387

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

388

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

389

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

390

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

391

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

392

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

393

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

394

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

395

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

396

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

397

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

399

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

400

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

401

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

402

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

404

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

406

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

407

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

408

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

409

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

410

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

411

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

412

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

413

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

414

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

415

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

416

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

417

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

418

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...

2004-12-07

419

Radiation damage and hardening of molybdenum in 29 MeV alpha particle straggling zone  

International Nuclear Information System (INIS)

Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.

420

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which ...

2005-01-01

421

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is ...

2005-01-01

422

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

423

Comparative studies on titanium and tantalum oxides thin film structures for laser mirrors, deposited by ion assisted gun  

International Nuclear Information System (INIS)

For obtaining radiation less damagable laser mirrors, a preliminary optimization of film fabrication suitable for the analysis of laser damage mechanism has been done as the first step. Here, the optimization requires not only the stable fabrication process but also the ideal film structure i.e., the amorphous and smooth film structure simultaneously, eliminating latently unwanted secondary effects such as light scattering during laser damage test. For this purpose, we adopted the ion assisted deposition (IAD) method and modified the deposition conditions for titanium and tantalum oxide films, both of which compose typical high index layers, and where SiO_2 layers are also chosen as low index layers because of their amorphous and smooth nature, in alternative multilayer laser mirrors. Surface and cross sectional film structures and film crystallinity are compared and characterized, using a high ...

1996-10-07

424

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

425

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

426

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

427

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

428

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

429

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

430

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

1991-09-01

431

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

432

Electron-ion recombination of neutral iron  

Energy Technology Data Exchange (ETDEWEB)

The total and state-specific electron-ion recombination rate coefficients are obtained for FeI. The calculations are carried out using a new ab initio method that incorporates both the radiative and the dielectronic recombination processes in an unified and self-consistent manner. The computations employ the close coupling approximation and the R-matrix method from atomic collision theory. A 52 state close coupling eigenfunction expansion dominated by the states of the ground 3d{sup 6}4s and excited 3d{sup 7}, 3d{sup 6}4p, 3d{sup 5}4s{sup 2}, and 3d{sup 5}4s4p configurations of FeII are used in the present calculations. The important electron correlation and radiation damping effects are included via explicit coupling of autoionization and radiative channels. This is the first detailed atomic calculation for the recombination rates for FeI. The present rates are considerably higher than the radiative ...

1997-04-01

433

Determination of the distribution of incident solar radiation in cavity receivers with approximately real parabolic dish collectors  

Energy Technology Data Exchange (ETDEWEB)

The absorption of solar heat and the attendant thermal and mechanical loadings on the tubes of cavity receivers depend predominantly on the flux distribution of the incident solar radiation. For an axially symmetric cavity receiver with a parabolic dish collector, it is simple to determine the insolation pattern on the receiver internal surfaces if the system is ideal. In such a system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun's central ray impinges on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions cannot be achieved in practice, and therefore the feasible parabolic dish system is referred to as a real system although, in actual fact, it is only an approximation to any actual system. The purpose of this paper is to devise calculation principles which permit analysis of a receiver designed for ideal conditions to verify its structural ...

1990-11-01

434

Benchmarks and models for 1-D radiation transport in stochastic participating media  

Energy Technology Data Exchange (ETDEWEB)

Benchmark calculations for radiation transport coupled to a material temperature equation in a 1-D slab and 1-D spherical geometry binary random media are presented. The mixing statistics are taken to be homogeneous Markov statistics in the 1-D slab but only approximately Markov statistics in the 1-D sphere. The material chunk sizes are described by Poisson distribution functions. The material opacities are first taken to be constant and then allowed to vary as a strong function of material temperature. Benchmark values and variances for time evolution of the ensemble average of material temperature energy density and radiation transmission are computed via a Monte Carlo type method. These benchmarks are used as a basis for comparison with three other approximate methods of solution. One of these approximate methods is simple atomic mix. The second approximate model is an adaptation of what is commonly called the Levermore-Pomraning model and ...

2000-08-21

435

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

436

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

437

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

438

Visible light emitting vertical cavity surface emitting lasers  

Science.gov (United States)

A vertical cavity surface emitting laser that emits visible radiation is built upon a substrate, then having mirrors, the first mirror on top of the substrate; both sets of mirrors being a distributed Bragg reflector of either dielectrics or other materials which affect the resistivity or of semiconductors, such that the structure within the mirror comprises a plurality of sets, each having a thickness of {lambda}/2n where n is the index of refraction of each of the sets; each of the mirrors adjacent to spacers which are on either side of an optically active bulk or quantum well layer; and the spacers and the optically active layer are from one of the following material systems: In{sub z}(Al{sub y}Ga{sub 1{minus}y}){sub 1{minus}z}P, InAlGaAs, AlGaAs, InGaAs, or AlGaP/GaP, wherein the optically active region having a length equal to m {lambda}/2n{sub eff} where m is an integer and n{sub eff} is the effective index of refraction of the laser ...

1995-06-27

439

Studies on radiation induced changes in bovine hemoglobin type A  

International Nuclear Information System (INIS)

In this paper the structural and functional changes of gamma irradiated bovine hemoglobin are presented. Aqueous solutions/1%/of HbO_2 were irradiated in air with doses ranging from 1 to 4 Mrad. Isoelectric focusing indicated change of the charge of irradiated hemoglobin. The isoelectric point of hemoglobin was displaced towards more acid values with increasing doses, up from 1 Mrad. Fingerprint analysis and peptide column chromatography of irradiated hemoglobin demonstrated disturbances increasing with the dose. These changes were confirmed by amino acid analysis which showed that Cys, Met, Trp, His, Pro and Tyr residues were destroyed or modified following irradiation. At doses exceeding 1 Mrad the irradiated solutions of hemoglobin showed a decrease of heme-heme interaction and an increase of affinity for oxygen. Differences observed in oxygen-dissociation curves seem to be correlated with the radiation induced destruction of amino acid ...

440

Mechanisms controlling the composition influence on radiation hardening and embrittlement of iron-base alloys  

International Nuclear Information System (INIS)

Classification and ranking of the solid solution on their reaction to the irradiation is suggested on the basis of binary system structure controlled by mixing enthalpy sign, melting temperatures relation of components and solidus curves slope. Several combinations of these characteristics permit to pick out three groups of substitutional elements capable of forming the vacancy-solute atom complexes either low-mobile or fast-mobile ones as compared to monovacancies migration. The radiation hardening (and embrittlement) of binary alloys should be intensified respectively either due to heterogeneous point defect clusters nucleation on solute traps or due to solute atom clusters/ precipitate formation. A local cohesion decrease may also occur especially if low-melting elements (characterized by low surface energy) are segregating on internal sinks or grain boundaries. The predicted specifics of different alloy group under irradiation and during ...

1994-06-20

441

EB-curing of coatings on wood composite boards  

International Nuclear Information System (INIS)

The industrial radiation processing using low energy electron beam (EB) accelerators lower than 300 keV offers high speed, safe technologies for the chemical conversion of thin layer coatings. Because of the nonselective mode of initiating chain reaction polymerization involving free radicals in synthetic coating layers and suitable substrates, the EB curing of the coatings on woods and papers has particular advantage. Hungary decided to start an up-to-date EB line to process cement-bound (CB) wood chipboards with pigmented acrylic coatings. The CB wood chipboards contain more than 60 % of portland cement and up to 40 % of wood particles. They are produced as large boads of 6 - 16 mm thickness. In their fireproof character and other aspects, they are similar to asbestos-cement boards without containing carcinagenic asbestos, and are stable against moisture and atmospheric influences. EB-cured acrylate coating improved further those properties, and makes them ...

1988-10-01

442

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...

1987-12-01

443

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of simultaneous ...

1987-01-01

444

Advances in beam physics and technology: Colliders of the future  

International Nuclear Information System (INIS)

Beams may be viewed as directed and focussed flow of energy and information, carried by particles and electromagnetic radiation fields (ie, photons). Often, they interact with each other (eg, in high energy colliders) or with other forms of matter (eg, in fixed targets, sychrotron radiation, neutron scattering, laser chemistry/physics, medical therapy, etc.). The whole art and science of beams revolve around the fundamental quest for, and ultimate implementation of, mechanisms of production, storage, control and observation of beams -- always directed towards studies of the basic structures and processes of the natural world and various practical applications. Tremendous progress has been made in all aspects of beam physics and technology in the last decades -- nonlinear dynamics, superconducting magnets and rf cavities, beam instrumentation and control, novel concepts and collider praradigms, to name a few. We illustrate ...

1994-11-14

445

Structure and electronic studies of defects in amorphous silicon. Final report, March 1980-February 1981  

Science.gov (United States)

Basic research of the structure and electronic properties of a-Si:H is reported with particular emphasis on the role of defects. The main findings are as follows: (1) low defect density material can be deposited at a high rate using SiH/sub 4/ diluted in He or Ne. Using Ar or Kr results in a high defect density and columnar material; (2) an electrical bias during deposition modifies the band gap, hydrogen concentration and structure; (3) the clustering of hydrogen in the regions between the columns is confirmed; (4) hydrogen diffusion is observed by NMR; (5) the oxidation of an a-Si:H surface results in approx. 3 x 10/sup 11/ cm/sup -2/ dangling bonds at the interface; (6) auger recombination of photoexcited carriers is a significant non-radiative mechanism at low temperatures; (7) non-radiative recombination by diffusion and capture at dangling bonds is observed at temperatures above 50 to 100/sup 0/K; ...

1981-08-01

446

Micro area analysis and measurement of electronic device material (challenge to utmost limits). Characterization of interface elect`ron structure by photon-and electron-spectroscopies; Denshi debaisu yo zairyo no bisho ryoiki bunseki-keisoku (kyokugen eno chosen). Koshi-denshi bunkoho ni yoru kaimen denshi jotai hyoka  

Energy Technology Data Exchange (ETDEWEB)

A method for detecting electrons emitted as secondary particles by photon incidence to a specimen, as well as a method of using the photons emitted by electron incidence as detecting particles are explained. Pd-Si(100)2{times}1 system is adopted for a case study of using photo-electron spectroscopy where synchrotron emitted light in soft X-ray region is used as the incident light. Pd atoms are deposited little by little on clean Si surface to investigate the electron structure of the surface, and the interface electron structure after bonded formation of Pd(thin film)-Si(substrate) is estimated. Radiation soft X-ray spectroscopy is employed to observe the real state of the bonded interface of Pd(thin film)-Si(substrate) prepared by depositing Pd film in a short period of time. In the case of radiation soft X-ray spectroscopy with electron beam excitation, bonded system of thin film and substrate can be ...

1995-07-20

447

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, ...

2009-05-26

448

Reaction cross-section and reduced strong absorption radius measurements of neutron-rich nuclei in the vicinity of closed shells N=20 and N=28  

Energy Technology Data Exchange (ETDEWEB)

The energy-integrated reaction cross-sections of several neutron-rich nuclei ({sup 17-22}N, {sup 19-24}O, {sup 21-27}F, {sup 23-30}Ne, {sup 26-33}Na, {sup 28-35}Mg, {sup 31-38}Al, {sup 33-40}Si, {sup 36-42}P, {sup 39-44}S, {sup 42-45}Cl, {sup 45,46}Ar), measured at intermediate energy (30-65 A-bar MeV), via direct method, are presented. Silicon detectors have been used as the active target as well as for particles identification. The reduced strong absorption radii r{sub 0}{sup 2} are extracted and compared to the data available from the literature. New measurements for 19 nuclei ({sup 27}F, {sup 27,30}Ne, {sup 33}Na, {sup 28,34-35}Mg, {sup 36-38}Al, {sup 38-40}Si, {sup 41-42}P, {sup 42-44}S, {sup 45}Cl) are revealed. From the study of the isospin dependence of the reduced strong absorption radius, a new quadratic parameterisation of the nuclear radii in the closed shell regions N=8 and N=28, is proposed. According to this parameterisation, the proton/neutron rich ...

2006-12-11

449

Proton-neutron interaction in odd--odd indium nuclei  

International Nuclear Information System (INIS)

An experimental study was performed in order to study the nuclear structure in odd--odd In isotopes. Low lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7AG(#alpha#,n#gamma#)"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#--#gamma# coincidence excitation and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0 "1"1"2 "1"1"4In were assigned to the (#pi#"-"1/sub 9/2/, #nu#h/sub 11/2) configuration. For the "1"1"0 "1"1"2"1"1"4In energy level schemes a model calculation was performed using the ...

1977-01-01

450

Investigation by XRF and XRD of Zn and Fe in Fe{sub x} Zn{sub 1-x} thin films  

Energy Technology Data Exchange (ETDEWEB)

Fe{sub x}Zn{sub 1-x} alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K{beta}/K{alpha} x-ray intensity ratios of Zn and Fe in Fe{sub x}Zn{sub 1-x} thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi {sup 241}Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in Fe{sub x}Zn{sub 1-x} thin films for different values of x. ...

2008-12-15

451

Investigation by XRF and XRD of Zn and Fe in Fex Zn1-x thin films  

International Nuclear Information System (INIS)

FexZn1-x alloys were electrochemically deposited on aluminum substrates from a sulfate bath. The K?/K? x-ray intensity ratios of Zn and Fe in FexZn1-x thin films have been experimentally studied. The energy dispersive x-ray fluorescence (EDXRF) technique was used to measure K x-ray photons. Samples were excited by using 59.5 keV photons emitted by a 50 mCi 241Am radioactive source. The emitted K x-rays were detected by an Ultra-LEGe detector having a resolution of 150 eV at 5.9 keV. In addition, the effect of bath composition on the phase structure was investigated by x-ray diffraction (XRD) analysis. The composition of the thin films was analyzed by atomic absorption spectrometry analysis. Iron content was shown to strongly affect the structure of Zn-Fe alloys. It was found that the K-shell x-ray intensity ratio changed in FexZn1-x thin films for different values of x. The reason for this change may be that the ...

2008-12-01

452

Decay of "1"0"1Mo and band structures of its daughter nuclide "1"0"1Tc in the projected shell model  

International Nuclear Information System (INIS)

The decay of molybdenum-101 has been investigated using the three-parameter (#gamma#-#gamma#-t) coincidence system of HPGe-HPGe detectors. According to the off-line analysis, the decay scheme was modified. The positions of 221.80, 318.00, 377.90; 452.50, 515.42, 1011.05, and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95, and 774.15 keV gamma rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52, and 1431.68 keV transitions have been reconfirmed, and the 1508.01 keV gamma ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#"- intensities and the values of log ft of most levels were calculated. Combining with the high-spin states observed by the in-beam #gamma#-ray spectroscopy of previous decay works, the structure of the excited positive/negative-parity yrast states of "1"0"1Tc is discussed using a projected shell ...

2006-01-01

453

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

454

Studies of nuclear processes at the Triangle Universities Nuclear Laboratory. Progress report, 1 September 1995--31 August 1996  

Energy Technology Data Exchange (ETDEWEB)

The Triangle Universities Nuclear Laboratory (TUNL)--a collaboration of Duke University, North Carolina State University, and the University of North Carolina at Chapel Hill--has had a very productive year. This report covers parts of the second and third year of a three-year grant between the US Department of Energy and the three collaborating universities. The TUNL research program focuses on the following areas: precision test of parity-invariance violation in resonance neutron scattering at LANSCE/LANL; parity violation measurements using charged-particle resonances in A = 20--40 targets and the A = 4 system at TUNL; chaotic behavior in the nuclei {sup 30}P and {sup 34}Cl from studies of eigenvalue fluctuations in nuclear level schemes; search for anomalies in the level density (pairing phase transition) in 1f-2p shell nuclei using GEANIE at LANSCE/LANL; parity-conserving time-reversal noninvariance tests using {sup 166}Ho resonances at Geel, ORELA, or LANSCE/LANL; nuclear ...

1996-09-01

455

K/sub. beta. //K/sub. cap alpha. / transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

Energy Technology Data Exchange (ETDEWEB)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of ...

1987-01-01

456

K/sub #beta#//K/sub #alpha#/ transition probability ratios from the measurement of fluorescent X-ray intensities of some lanthanide compounds  

International Nuclear Information System (INIS)

The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of Scofield and ...

1987-01-01

457

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The 'spot scanning' ...

2007-07-01

458

An Assessment of the Detection of Highly Enriched Uranium and its Use in an Improvised Nuclear Device using the Monte Carlo Computer Code MCNP-5  

Science.gov (United States)

In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined via Monte Carlo ...

2007-04-01

459

Cloning, Expression, Crystallization and Preliminary Crystallographic Analysis of a Pentapeptide-repeat Protein (Rfr23) from the Bacterium Cyanothece 51142l  

International Nuclear Information System (INIS)

A unique feature of cyanobacteria genomes is the abundance of genes that code for hypothetical proteins containing tandem pentapeptide repeats approximately described by the consensus motif A(N/D)LXX. To date, the structures of two pentapeptide-repeat proteins (PRPs) have been determined, with the tandem pentapeptide-repeat sequences observed to adopt a novel type of right-handed quadrilateral ?-helix, or Rfr-fold, in both structures. One structure, Mycobacterium tuberculosis MfpA, is a 183-residue protein that contains 30 consecutive pentapeptide repeats and appears to offer antibiotic resistance by acting as a DNA mimic. The other structure, Cyanothece 51142 Rfr32, is a 167-residue protein that contains 21 consecutive pentapeptide repeats. The function of Rfr32, like the other 35 hypothetical PRPs identified in the genome of Cyanothece, is unknown. In an effort to understand the role of PRPs in ...

2006-01-01

460

The dependence of photovoltage of the system APhV-films photoresistor on the capacity of X-ray radiation dose  

International Nuclear Information System (INIS)

Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was ...

2004-08-23

461

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

463

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

464

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

465

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

466

The Formation of the Low-sized High Density Plasma Structures in the Self-maintained Plasma-beam Discharge  

International Nuclear Information System (INIS)

The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.

2006-01-01

467

Summing Radiative Corrections to the Effective Potential  

CERN Document Server

When one uses the Coleman-Weinberg renormalization condition, the effective potential $V$ in the massless $\\phi_4^4$ theory with O(N) symmetry is completely determined by the renormalization group functions. It has been shown how the $(p+1)$ order renormalization group function fix the N$^{p}$LL order contribution to $V$. We discuss here how, in addition to fixing the N$^{p}$LL contribution to $V$, the $(p+1)$ order renormalization group functions also can be used to determine portions of the N$^{p+n}$LL contributions to $V$. When these contributions are summed to all orders, the singularity structure of \\mcv is altered. An alternate approach to fixing \\mcv in terms of the renormalization group functions is shown to eliminate dependence on the background field if spontaneous symmetry breaking occurs.

2010-01-01

468

Studies on application of radiation and radioisotopes -The application of irradiation techniques for food preservation and process improvement-  

Energy Technology Data Exchange (ETDEWEB)

The project was designed to solve the infra structural problem required for commercialization of food irradiation. In improvement of physical properties of corn starch, gamma irradiation was effective for increasing glucose productivity and for substituting traditional modified starches (acid modified starch, oxidized starch). In immobilization of microorganisms, the mass production method of natural red pigment was developed by using immobilized mold pellets. In Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield. In evaluation of wholesomeness, gamma irradiated red ginseng could be safe on the genotoxic point of view. And also, six items of irradiated foods approved for human consumption from Korea ministry of health and welfare in May 19, 1995. 30 figs, 20 tabs, 54 refs. (Author).

1995-07-01

469

Silicate emission in Orion  

CERN Document Server

We present mid-infrared spectro-imagery and high-resolution spectroscopy ofthe Orion bar and of a region in the Orion nebula. These observations have beenobtained in the Guaranteed Time with the Circular Variable Filters of the ISOcamera (CAM-CVF) and with the Short Wavelength Spectrometer (SWS), on board theEuropean Infrared Space Observatory (ISO). Our data shows emission fromamorphous silicate grains from the entire HII region and around the isolatedO9.5V star Theta2 Ori A. The observed spectra can be reproduced by a mixture ofinterstellar silicate and carbon grains heated by the radiation of the hotstars present in the region. Crystalline silicates are also observed in theOrion nebula and suspected around Theta2 Ori A. They are probably ofinterstellar origin. The ionization structure and the distribution of thecarriers of the Aromatic Infrared Bands (AIBs) are briefly discussed on thebasis of the ISO observations.

2000-01-01

470

Recent observations on the evolution of secondary-phase particles in zircaloy-2 under irradiation in a BWR to high burn-up  

Energy Technology Data Exchange (ETDEWEB)

The influence of radiation on the corrosion of the fuel claddings in a Light Water Reactor (LWR) has been the subject of many investigations, and different aspects of the overall phenomena have been studied by different techniques. Analysis of the evolution of Secondary-Phase Particles (SPPs) for different periods of immersion of the cladding in the reactor enables the rate of corrosion to the structure of the material to be correlated. In the case of Zircaloy-2 in a Boiling Water Reactor (BWR), SPPs are dissolved under irradiation, and their dissolution affects the rate of oxidation and other correlated phenomena. In recent studies, the Zircaloy-2 in claddings loaded in the Leibstadt BWR are analysed after one, three and five cycles. Results are presented, and give an account of the changes which occurred in the materials under irradiation. (authors)

2000-07-01

471

Polynomial curve fitting method for refraction-angle extraction in diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)

2009-11-01

472

Is cold better ? - exploring the feasibility of liquid-helium-cooled optics.  

Energy Technology Data Exchange (ETDEWEB)

Both simulations and recent experiments conducted at the Advanced Photon Source showed that the performance of liquid-nitrogen-cooled single-silicon crystal monochromators can degrade in a very rapid nonlinear fashion as the power and for power density is increased. As a further step towards improving the performance of silicon optics, we propose cooling with liquid helium, which dramatically improves the thermal properties of silicon beyond that of liquid nitrogen and brings the performance of single silicon-crystal-based synchrotrons radiation optics up to the ultimate limit. The benefits of liquid helium cooling as well as some of the associated technical challenges will be discussed, and results of thermal and structural finite elements simulations comparing the performance of silicon monochromators cooled with liquid nitrogen and helium will be given.

1999-09-30

473

EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction studies, electron-ion interactions studies, retrap and ion ...

1996-10-01

474

Brane-world cosmology with black strings  

CERN Document Server

We consider the simplest scenario when black strings (cigars) penetrate the cosmological brane. As a result, the brane has a Swiss-cheese structure, with Schwarzschild black holes immersed in a Friedmann-Lema\\^{\\i}tre-Robertson-Walker brane. There is no dark radiation in the model, the cosmological regions of the brane are characterized by a cosmological constant $\\Lambda$ and flat spatial sections. Regardless of the value of $\\Lambda$, these brane-world universes forever expand and forever decelerate. The totality of source terms in the modified Einstein equation sum up to a dust, establishing a formal equivalence with the general relativistic Einstein-Straus model. However in this brane-world scenario with black strings the evolution of the cosmological fluid strongly depends on $\\Lambda$. For $\\Lambda$ less or equal to zero it has positive energy density $\\rho$ and negative pressure $p$ and at late times it behaves as in the ...

2006-01-01

475

A He-gas Cooled, Stationary Granular Target  

CERN Document Server

In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.

2003-01-01

476

THE RADIATION INDUCED OXIDATION AND REDUCTION REACTIONS OF IRON IN AQUEOUS SOLUTIONS. VII. THE DIRECT OBSERVATION OF REDOX PROCESSES IN THE IRRADIATED Fe-H$sub 2$SO$sub 4$-CARBOXYLIC ACIDS- H$sub 2$ -O$sub 2$ SYSTEM. THE EFFECTS OF THE STRUCTURE OF ACIDS  

Science.gov (United States)

The effects of the structure of a carboxylic acid on the processes of oxidation and reduction of iron ions in irradiated aqueous solutions were directly observed during irradiation. The solutions contained the mono- or dicarboxylic acid, H/sub 2/SO/sub 4/, Fe(NH/sub 4/)/sub 2/(SO/sub 4/)/sub 2/ and O/sub 2/. Th e ferrous oxidation was rather independent of the acid and its concentration, but the reduction of ferric was possible in the presence of formic, oxalic, or valeric acid only. The radical formed from the valeric acid acts similar to those formed from hydrocarbons. The G-values of oxidation and reduction of the iron ions were established. The molar extinction coefficients for oxalic and malonic complexes of ferric ions were determined. (auth)

1963-01-01

477

Structure and kinetics of Sn whisker growth on Pb-free solder finish  

Energy Technology Data Exchange (ETDEWEB)

Standard Leadframes used in surface mount technology are finished with a layer of eutectic SnPb for passivation and for enhancing solder wetting during reflow. When eutectic SnPb is replaced by Pb-free solder, especially the eutectic SnCu, a large number of Sn whiskers are found on the Pb-free finish. Some of the whiskers are long enough to become shorts between the neighboring legs of the leadframe. How to suppress their growth and how to perform accelerated test of Sn whisker growth are crucial reliability issues in the electronic packaging industry. In this paper, we report the study of spontaneous Sn whisker growth at room temperature on eutectic SnCu and pure Sn finishes. Both compressive stress and surface oxide on Sn are necessary conditions for whisker growth. Structure and stress analyses by using the micro-diffraction in synchrotron radiation are reported. Cross-sectional electron microscopy, with samples prepared by focused ion beam, ...

2002-07-11

478

Research and development program on solar thermal use in the high temperature range. Forschungs- und Entwicklungsprogramm zur solarthermischen Nutzung im Hochtemperaturbereich  

Energy Technology Data Exchange (ETDEWEB)

In the context of the research project, the physical basis of the direct decoupling of highly concentrated solar radiation in materials without the detour via absorbing heat exchanger walls was examined. Also, the first chemical processes suitable for the effective long-term storage of solar energy were analysed, relevant experiments were carried out and the necessary receiver techniques for high temperature applications were provided. The principle of direct coupling was examined on fluidized beds on the one hand and on cavity receivers, on the other hand. The contribution shows the results achieved in detail. It is recorded that first processes for storing solar energy in chemical reactions were able to be examined. Alkaline earth hydroxides accommodated in ceramic honeycomb structures seem to be possible as stores for medium temperature ranges around 500deg C. Investigations on receiver structure materials are also ...

1988-03-01

479

RCRA closure of the Building 3001 Storage Canal  

Energy Technology Data Exchange (ETDEWEB)

The 3001 Storage Canal is located under portions of Buildings 3001 and 3019 at Oak Ridge National Laboratory (ORNL) and has a capacity of approximately 62,000 gallons of water. The term canal has historically been used to identify this structure, however, the canal is an in-ground reinforced concrete structure satisfying the regulatory definition of a tank. From 1943 through 1963, the canal in Building 3001 was designed to be an integral part of the system for handling irradiated fuel from the Oak Ridge Graphite Reactor. Because one of the main initial purposes of the reactor was to produce plutonium for the chemical processing pilot plant in Building 3019, the canal was designed to be the connecting link between the reactor and the pilot plant. During the war years, natural uranium slugs were irradiated in the reactor and then pushed out of the graphite matrix into the system of diversion plates and chutes which directed the fuel into the deep ...

1992-09-01

480

Materials considerations for the National Spallation Neutron Source target  

Energy Technology Data Exchange (ETDEWEB)

The National Spallation Neutron Source (NSNS), in which neutrons are generated by bombarding a liquid mercury target with 1 GeV protons, will place extraordinary demands on materials performance. The target structural material will operate in an aggressive environment, subject to intense fluxes of high energy protons, neutrons, and other particles, while exposed to liquid mercury and to water. Components that require special consideration include the Hg liquid target container and protective shroud, beam windows, support structures, moderator containers, and beam tubes. In response to these demands a materials R and D program has been developed for the NSNS that includes: selection of materials; calculations of radiation damage; irradiations, post irradiation testing, and characterization; compatibility testing and characterization; design and implementation of a plan for monitoring of materials performance in service; and ...

1997-08-01

481

Highly ordered thin films of polyheterocycles: A synchrotron radiation study of polypyrrole and polythiophene Langmuir-Blodgett films  

Energy Technology Data Exchange (ETDEWEB)

Langmuir-Blodgett films have been made with 3-n-hexadecylpyrrole and 3-n-octadecylpyrrole monomers and copolymers with unsubstituted pyrrole made by chemical polymerization at the air-water interface on a subphase containing FeCl/sub 3/. Langmuir-Blodgett films consisting of mixtures of stearic acid and alkylsubstituted polythiophenes have also been made as bilayer films. The orientation of single and multilayer films on platinum substrates have been studied by Near Edge X-ray Absorption Fine Structure Spectroscopy which also gives information about charge transfer interactions between the aromatic groups and the metallic substrates. The alkylsubstituted pyrroles form highly ordered two-dimensional structures. FeCl/sub 3/ initiated copolymerization with unsubstituted pyrrole leads to a more disordered system. In the case of polythiophene-stearic acid bilayers, the stearic acid layers are highly ordered. The poly(alkyl thiophene) layers ...

1988-01-01

482

Grain boundary transport in x-ray irradiated polycrystalline diamond  

International Nuclear Information System (INIS)

The transport properties of a 'thin' polycrystalline diamond film are analyzed after the sample exposure to 8.06-keV x-ray radiation. Structure and morphology of the as-grown film have been evaluated by Raman, x-ray diffraction, and scanning electron microscopy techniques. The transport properties have been investigated by measuring dark current-voltage characteristics in the temperature range of 60 to 360 K. Ohmic transport has been evidenced on the as-grown film up to 1.16x10"5 V/cm. After irradiation, nonlinear contributions to the dark current have been evidenced and related to field-assisted thermal ionization of traps. Below 200 K, hopping mechanisms have been observed. Correlations have been found among x-ray irradiation, density of traps involved in the transport processes, and the nonhomogeneous nature of the sample. A simple model of the grain boundary structure is proposed to explain the observations.

2003-05-15

483

What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?  

International Nuclear Information System (INIS)

Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the least contrast media and had the least frequency of streak artifacts, but there were no significant differences in coronary artery attenuation, image ...

2010-08-01

484

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the ...

2006-07-01

487

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

494

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

497

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...

2006-07-01

498

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01