WorldWideScience
1

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

2

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

3

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

5

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this ...

1996-01-01

6

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic ...

2001-01-01

7

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

8

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

9

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

10

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

11

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

12

Application of a finite element method to leak before break (LBB) of a heat exchanger  

International Nuclear Information System (INIS)

The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial ...

2003-08-17

14

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

15

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the ...

2003-03-04

16

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here ...

2009-11-02

17

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant ...

1995-10-01

18

Artificial intelligence: the future in nuclear plant maintenance  

Energy Technology Data Exchange (ETDEWEB)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-12-01

19

Artificial intelligence: the future in nuclear plant maintenance  

International Nuclear Information System (INIS)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-09-23

20

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

21

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

22

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These ...

2010-09-07

23

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

24

High order statistical signatures from source-driven measurements of subcritical fissile systems  

Energy Technology Data Exchange (ETDEWEB)

This research focuses on the development and application of high order statistical analyses applied to measurements performed with subcritical fissile systems driven by an introduced neutron source. The signatures presented are derived from counting statistics of the introduced source and radiation detectors that observe the response of the fissile system. It is demonstrated that successively higher order counting statistics possess progressively higher sensitivity to reactivity. Consequently, these signatures are more sensitive to changes in the composition, fissile mass, and configuration of the fissile assembly. Furthermore, it is shown that these techniques are capable of distinguishing the response of the fissile system to the introduced source from its response to any internal or inherent sources. This ability combined with the enhanced sensitivity of higher order signatures indicates that these techniques will be of ...

1998-04-01

25

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

26

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

27

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

28

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

29

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

30

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

31

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

32

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

33

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

34

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the ...

2007-01-01

35

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

36

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

37

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

38

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the ...

2007-01-01

39

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

40

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

41

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

42

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

43

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

44

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

45

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the ...

2007-01-01

46

A solution for solid state detector and preamplifier protection, during HV application and removal transition periods  

International Nuclear Information System (INIS)

Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).

47

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization ...

48

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

50

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

52

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

53

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

54

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation ...

1991-03-13

55

Acceptance testing in digital systems of mammography. Protocols applicability  

International Nuclear Information System (INIS)

Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure ...

56

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

57

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton scattering sources and we ...

2009-09-01

58

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For ...

2006-11-13

59

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

60

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

61

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is ...

1980-01-01

62

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

63

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

64

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated ...

1992-10-25

65

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from ...

2006-07-01

66

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

67

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum ...

2004-12-07

68

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

69

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background ...

2004-01-01

70

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

71

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

72

Single event effects in the pixel readout chip for BTeV  

Energy Technology Data Exchange (ETDEWEB)

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.

2001-12-07

73

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For ...

2005-11-23

74

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and ...

1995-11-01

75

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

76

A PDA-Based ECG Beat Detector for Home Cardiac Care.  

Science.gov (United States)

Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192

2005-01-01

77

Study of particles trapped by a magnetic field  

Science.gov (United States)

A new type of radiation which occurs when particles are accelerated in the field of a longitudinal wave and in a transverse magnetic field is studied. The characteristics of such spontaneous radiation are obtained, and the influence of collective effects on the radiation is analyzed. The application of the findings to the theory of free electron lasers is discussed. 8 references.

1986-01-01

78

Radiation exposure due to X-rays of the hip joint in babies  

International Nuclear Information System (INIS)

Exact anatomic knowledge about the location of the gonads and the application of corresponding measures of radiation protection are the preconditions for an efficient reduction of the danger of a possible genetic damage as a result of radiation exposition during X-ray examination of the hip joint of newborns. (VJ).

79

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...

2007-08-21

80

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the non-destructive evaluation (NDE) of ...

2001-07-01

81

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

82

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

83

Facility for studying photon-neutron reactions under a beam of braking radiation  

International Nuclear Information System (INIS)

A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.

84

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

85

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

86

Feynmann variance-to-mean method  

Energy Technology Data Exchange (ETDEWEB)

The Feynmann and other fluctuation techniques have been shown to be useful for determining the multiplication of subcritical systems. The moments of the counting distribution from neutron detectors is analyzed to yield the multiplication value. We present the methodology and some selected applications and results and comparisons with Monte Carlo calculations.

1985-01-01

87

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

88

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude ...

2000-01-01

89

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01

90

Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications  

CERN Document Server

Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.

2007-01-01

91

Application of proportional counters in Polish medicine and agriculture  

Energy Technology Data Exchange (ETDEWEB)

In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.

1996-12-31

92

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had ...

2002-01-01

93

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

94

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing ...

2004-12-21

95

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

96

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

97

Development of a computerized portal verification scheme for pelvic treatment fields  

International Nuclear Information System (INIS)

Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge ...

1996-09-01

98

Some considerations about future interferometric GW detectors  

International Nuclear Information System (INIS)

The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.

2004-03-07

99

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward ...

2004-01-01

100

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

101

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

102

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

103

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

104

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, ...

2004-10-13

105

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

106

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron ...

1997-07-01

107

The chemistry of UV and BE radiation curing  

International Nuclear Information System (INIS)

The application of photopolymerisation (UV) and electron beams (EB) technologies in radiation rapid cure (PRC) processing is discussed. The chemistry associated with such reactions and the mechanisms of the processes are treated. The occurrence of concurrent grafting to substrate with radiation curing of films is shown to be an advantage in enhancing the properties of certain finished products. The parameters influencing the optimum grafting yield in such PRC processes are discussed. In many applications, the chemistry of such processes combined with the machine, specially for EB is shown. (author).

1987-09-19

108

Radiation hazards from medical applications  

International Nuclear Information System (INIS)

An introduction is presented on the radiation hazards connected with biomedical radiography and nuclear medicine. The frequency of radiodiagnostic efforts was rather high in the Netherlands. This was reduced considerably by abolishing the thorax screening of the population. About diagnostic nuclear medicine less can be said because far fewer numerical data are available. An exposition of genetically and somatically significant doses and how to compute them is given. The drawing up of a profit versus risk evaluation for medical applications of ionizing radiations is recommended. (Auth.).

1980-05-31

109

Gamma-rays and neutrinos from the pulsar wind nebulae  

Energy Technology Data Exchange (ETDEWEB)

We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab ...

2005-08-01

110

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

111

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. ...

2001-01-01

112

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

113

Radiation risks for medical applications  

International Nuclear Information System (INIS)

The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).

1980-05-31

114

Measuring equipment for the monitoring of air pollution control - a market review  

Energy Technology Data Exchange (ETDEWEB)

The paper abstracted gives a tabular survey of the suppliers and applications of measuring equipment. Equipment is available for the following fields of application: Continuous measuring instruments for stationary operation, laboratory equipment for sampling and hand equipment for mobile measurement, sampling equipment for examining emissions and gases, detectors, storage and evaluation equipment and meteorological instruments. (PW).

1986-01-01

115

An integrating dosimeter for pulsed radiation  

Science.gov (United States)

A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.

1983-12-01

116

Application of low dose radiation for preservation of sea foods  

International Nuclear Information System (INIS)

Treatment of food with low doses of gamma radiation has been recognized to have two main advantages. These consist of: (1) improvement of food safety by elimination of pathogens and (2) reduction of microbial spoilage and extension of shelf life of perishable items by reducing the number of viable spoilage organisms. Studies during the last few decades have conclusively proved the beneficial effects of radiation with respect to fishery products. The three potential areas of application to fish products include: (i) radurization for shelf life extension (ii) radicidation to eliminate food borne pathogens in the products and (iii) radiation treatment to dried products to control insects.

1994-03-01

117

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is ...

1995-12-31

118

Nuclear radiation detectors on II-VI compounds  

International Nuclear Information System (INIS)

Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy ...

1993-10-13

119

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, ...

2003-01-01

120

NASA Technical Reports Server - Radionuclide X-ray fluorescence ...  

Science.gov (United States)

Aug 1, 1972 ... The principles of radionuclide excitation of X-ray fluorescence radiation and its application in analytic chemistry are discussed.

122

3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).

1983-12-01

123

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the ...

1999-07-01

124

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...

2006-02-15

125

Quantum locking of mirrors in interferometric measurements  

International Nuclear Information System (INIS)

We discuss the use of active control to reduce mirror position fluctuations at the quantum level. We have shown in a recent experiment that it is possible to reduce the thermal noise of a mirror by measuring and controlling its motion with an optomechanical sensor based on a high-finesse optical cavity. This approach can be extended to lock the mirror motion at the quantum level, and to suppress the quantum effects of radiation pressure in interferometric measurements such as gravitational-wave detectors. The sensitivity improvement is furthermore independent of losses in the interferometer.

2004-03-07

126

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

127

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

128

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

129

A combined real time wide range energy neutron dosimeter and survey meter for high neutron dose rates with Si surface barrier detectors  

International Nuclear Information System (INIS)

The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene ...

1983-06-01

130

National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards  

International Nuclear Information System (INIS)

As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible ...

2009-12-16

131

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The 'spot ...

2007-07-01

132

Possible applications of plasma lens in high energy physics  

Energy Technology Data Exchange (ETDEWEB)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition {ital k}{sub {ital p}}{sigma}{sub {ital x}}{approx_gt}1, and not {ital k}{sub {ital p}}{sigma}{sub {ital y}}{approx_gt}1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for {gamma}{gamma} colliders is discussed.{copyright}{ital American Institute of Physics.}

1996-01-01

133

Possible applications of plasma lens in high energy physics  

International Nuclear Information System (INIS)

The concept of the self-focusing plasma lens in various beam-plasma interaction regimes is reviewed. We found that in order for current neutralization to occur, it is only necessary to attain the condition k_p#sigma#_x approx-gt 1, and not k_p#sigma#_y approx-gt 1, for flat beams. This helps to substantially reduce the required plasma density for beamstrahlung suppression. We also report on a recent calculation on the detector backgrounds induced by a plasma lens. It is shown that these backgrounds are within the tolerance of all major components in a NLC-like detector. Finally, one other potential application of plasma lens for #gamma##gamma# colliders is discussed.copyright American Institute of Physics.

134

Photoresponsivity of ultraviolet detectors based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloys  

Energy Technology Data Exchange (ETDEWEB)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 {mu}m In{sub x}Al{sub y}Ga{sub 1-x-y}N alloy grown on 0.5-1.0 {mu}m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In{sub x}Al{sub y}Ga{sub 1-x-y}N detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low ...

2000-08-07

135

Photoresponsivity of ultraviolet detectors based on In_xAl_yGa_1_-_x_-_yN quaternary alloys  

International Nuclear Information System (INIS)

We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In_xAl_yGa_1_-_x_-_yN quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 #mu#m In_xAl_yGa_1_-_x_-_yN alloy grown on 0.5-1.0 #mu#m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In_xAl_yGa_1_-_x_-_yN detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In_xAl_yGa_1_-_x_-_yN quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to ...

2000-08-07

136

A large surface neutron and photon detector for civil security applications  

Energy Technology Data Exchange (ETDEWEB)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-21

137

A large surface neutron and photon detector for civil security applications  

International Nuclear Information System (INIS)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-11

138

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. ...

1992-03-16

139

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

140

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

141

The development and testing of emissivity enhancement coatings for thermophotovoltaic (TPV) radiator applications  

Energy Technology Data Exchange (ETDEWEB)

One requirement of a thermophotovoltaic (TPV) radiator is to efficiently emit photons at high temperatures to TPV cells for conversion to electric power. Because many candidate radiator materials with adequate structural properties display low emissivity, coatings or other surface modifications are required for enhancement of emissivity. Six plasma sprayed coatings and one textured surface demonstrated adequate thermal stability and emittance values of 0.8 or greater. Promising attributes of modified surfaces are identified.

1999-03-01

142

Effect of substrate on the results of measuring coating thickness according to radiation scattered by substrate  

International Nuclear Information System (INIS)

The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.

143

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

144

A final report for: Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode ...

1999-04-01

145

SENSITIVITY STUDIES FOR AN IN-SITU PARTIAL DEFECT DETECTOR (PDET) IN SPENT FUEL USING MONTE CARLO TECHNIQUES  

Energy Technology Data Exchange (ETDEWEB)

This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.

2008-04-28

146

Quantification of thin film crystallographic orientation using X-ray diffraction with an area detector  

Energy Technology Data Exchange (ETDEWEB)

As thin films become increasingly popular (for solar cells, LEDs, microelectronics, batteries), quantitative morphological information is needed to predict and optimize the film's electronic, optical and mechanical properties. This quantification can be obtained quickly and easily with X-ray diffraction using an area detector and synchrotron radiation in two simple geometries. In this paper, we describe a methodology for constructing complete pole figures for thin films with fiber texture (isotropic in-plane orientation). We demonstrate this technique on semicrystalline polymer films, self-assembled nanoparticle semiconductor films, and randomly-packed metallic nanoparticle films. This method can be immediately implemented to help understand the relationship between film processing and microstructure, enabling the development of better and less expensive electronic and optoelectronic devices.

2010-02-19

147

Programmable radionuclide X-ray fluorescence multi-channel spectrometric analyzer, type 123-1  

International Nuclear Information System (INIS)

The whole equipment consists of three separate portable parts: a detector case, a microprocessor and a graphic TV monitor. Magnetic tape memory and an x-y recorder can be connected for recording the measured spectra. The analyzer contains two built-in exchangeable excitation radionuclides. Fluorescence and scattered radiation is detected using a proportional detector. The detected pulses are analyzed by a 256-channel analyzer and the results are shown on the display. The device may be used in mining laboratories, coal and ore dressing plant control rooms or in mining fields of open cast mines for quick detection of the quality of mined or dressed raw materials. (E.S.). 1 fig.

1988-01-01

148

Comparison of energy flows in deep inelastic scattering events with and without a large rapidity gap  

Energy Technology Data Exchange (ETDEWEB)

Energy flows in deep inelastic electron-proton scattering are investigated at a centre-of-mass energy of 296 GeV for the range Q{sup 2}{>=}10 GeV{sup 2} using the ZEUS detector. A comparison is made between events with and without a large rapidity gap between the hadronic system and the proton direction. The energy flows, corrected for detector acceptance and resolution, are shown for these two classes of events in both the HERA laboratory frame and the Breit frame. From the differences in the shapes of these energy flows we conclude that QCD radiation is suppressed in the large-rapidity-gap events compared to the events without a large rapidity gap. (orig.)

1994-07-01

152

Survey of radiation protection programmes for transport; Etude des programmes de radioprotection pour les transports de matieres radioactives  

Energy Technology Data Exchange (ETDEWEB)

The survey of radiation protection programmes for transport has been jointly performed by three scientific organisations I.P.S.N. (France), G.R.S. ( Germany), and N.R.P.B. (United kingdom) on behalf of the European Commission and the pertaining documentation summarises the findings and conclusions of the work that was undertaken with the principal objectives to provide guidance on the establishment, implementation and application of radiation protection programmes for the transport of radioactive materials by operators and the assessment and evaluation of such programmes by the competent authority and to review currently existing radiation protection programmes for the transport of radioactive materials. (N.C.)

2001-07-01

153

Free electron radiation and the Beijing Free Electron Laser  

International Nuclear Information System (INIS)

Various particle-photon or beam-wave interactions are discussed. To be of use as intense radiation sources, it is necessary that these interactions produce coherent radiation. The free electron laser (FEL), developed on the basis of undulator radiation, is the result of many years of interaction between physics and technology. It has many features, such as continuous tunability over a wide wavelength range, excellent optical quality, high power and short pulse capability, and thus has many potential applications. FEL development in China and abroad are mentioned and the Beijing FEL presented to illustrate the physics and technology involved in an FEL project.

154

Synchrotron radiation from electron beams in plasma-focusing channels.  

Science.gov (United States)

Spontaneous radiation emitted from relativistic electrons undergoing betatron motion in a plasma-focusing channel is analyzed, and applications to plasma wake-field accelerator experiments and to the ion-channel laser (ICL) are discussed. Important similarities and differences between a free electron laser (FEL) and an ICL are delineated. It is shown that the frequency of spontaneous radiation is a strong function of the betatron strength parameter a(beta), which plays a role similar to that of the wiggler strength parameter in a conventional FEL. For a(beta) > or approximately 1, radiation is emitted in numerous harmonics. Furthermore, a(beta) is proportional to the amplitude of the betatron orbit, which varies for every electron in the beam. The radiation spectrum emitted from an electron beam is calculated by averaging the single-electron spectrum over the electron ...

2002-05-20

155

Radiation hardening of smart electronics  

International Nuclear Information System (INIS)

Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation ...

156

A Radiation Laboratory Curriculum Development at Western Kentucky University  

Science.gov (United States)

We present the latest developments for the radiation laboratory curriculum at the Department of Physics and Astronomy of Western Kentucky University. During the last decade, the Applied Physics Institute (API) at WKU accumulated various equipment for radiation experimentation. This includes various neutron sources (computer controlled d-t and d-d neutron generators, and isotopic 252 Cf and PuBe sources), the set of gamma sources with various intensities, gamma detectors with various energy resolutions (NaI, BGO, GSO, LaBr and HPGe) and the 2.5-MeV Van de Graaff particle accelerator. XRF and XRD apparatuses are also available for students and members at the API. This equipment is currently used in numerous scientific and teaching activities. Members of the API also developed a set of laboratory activities for undergraduate students taking classes from the physics curriculum (Nuclear Physics, Atomic Physics, and ...

2009-03-10

157

Secure direct communication using the 'polarization' entangled atomic ensembles  

Energy Technology Data Exchange (ETDEWEB)

We propose a scheme with potential experimental realization to generate 'polarization' entanglement between two atomic ensembles and show one of the applications - a novel secure communication allowing asymptotically key distribution and quasisecure direct communication. The scheme involves laser manipulation of atomic ensembles, adjustable quarter- and half-wave plates, beam splitters, polarizing beam splitters and single-photon detectors, and well fits the status of the current experimental technology.

2004-02-14

158

In-beam conversion electron spectroscopy using the SACRED array  

International Nuclear Information System (INIS)

Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.

159

Application of isotope-excitation x-ray fluorescence (XRF) analysis for aluminium production  

International Nuclear Information System (INIS)

An energy sensitive Si(Li) detector XRF analyzer built by ATOMKI, Hungary, has been applied for various analytical purposes in alumina production at the Almasfuezitoe Alumina Company, Hungary. Specifically, the CaO content in red mud was determined by the new XRF technique using isotope excitation sources. The analysis of other components is under way. (R.P.).

160

Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium  

Energy Technology Data Exchange (ETDEWEB)

We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. ...

2004-03-09

161

Effective per-capita dose as a yardstick for medical radiation exposure of the population - a supplement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the ...

1984-06-01

162

Electron accelerators, present and future applications  

International Nuclear Information System (INIS)

The development and occurrence of new electron accelerators and applications are according to the human society development law, as a whole. The period of economic standstill is generating an intense creative activity in the domain of science and engineering which also resulting in great achievements in the field of electron accelerators. This paper presents the basic principle of the electron beam applications and the accelerators required characteristics for their present and potential applications in the domains: radiation sources, diagnostics, radiation processing, energetics, environment, defense and basic sciences. All these are correlated to the new generation of accelerators which, for the acceleration process, may employ electromagnetic fields generated by standard sources, atomic lasers, free electron lasers, Cerenkov effect, Smith - Purcell effect, electron beams, plasma, ...

163

Radiation processing of wood-plastic composites  

International Nuclear Information System (INIS)

There are three main types of radiation-processed composite material derived from plastics and fibrous natural polymers. The first are the monomer-impregnated, radiation-treated wood-plastic composites (WPC). They became a commercial success in the early 1970s. More recently, work has focused on improving the WPCs by creating in them interpenetrating network (IPN) systems by the use of appropriate multifunctional oligomers and monomers. The main kinetic features of radiation-initiated chain polymerization remain applicable even in impregnated wood. The second type are the plastics filled or reinforced with dispersed wood fiber or other cellulosics (WFRP). In their case, radiation processing offers a new opportunity to apply radiation-reactive adhesion promoters between wood or cellulosic fibers and the thermoplastic matrices. The third type are the laminar ...

164

Production of plastified wood with stronger static bending strength means of polymerization induced by gamma radiation; Producao da madeira plastificada de elevada resistencia a flexao estatica mediante polimerizacao induzida por raios gama  

Energy Technology Data Exchange (ETDEWEB)

The use of gamma radiation to obtain wood-polymer composites is one of the applications of radiation that presents the most commercial interest. The process, denominated radiopolymerization, comprises the impregnation of monomers into the completely dried wood followed by exposure to gamma radiation to induce polymerization of the impregnated monomers. I this context, the present work aimed the application of this process to seven kinds of wood existing in the brazilian forests. The considered monomer is styrene and the gamma source is Cobalt-60. The obtained wood-polystyrene composites were found to have stronger static bending strength. (author)

1999-07-01

165

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such ...

2009-03-01

166

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...

2010-10-01

167

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray ...

1987-05-13

168

Implementation and modification of a three-dimensional radiation stress formulation for surf zone and rip-current applications  

British Library Electronic Table of Contents (United Kingdom)

Regional Ocean Modeling System (ROMS v 3.0), a three-dimensional numerical ocean model, was previously enhanced for shallow water applications by including wave-induced radiation stress forcing provided through coupling to wave propagation models (SWAN, REF/DIF). This enhancement made it suitable for surf zone applications as demonstrated using examples of obliquely incident waves on a planar beach and rip current formation in longshore bar trough morphology (Haas and Warner, 2009). In this contribution, we present an update to the coupled model which implements a wave roller model and also a modified method of the radiation stress term based on Mellor (2008, 2011a,b,in press) that includes a vertical distribution which better simulates non-conservative (i.e., wave breaking) processes and ...

2011-01-01

169

Gas sensor arrays (electronic noses) and their combination with trap techniques  

Energy Technology Data Exchange (ETDEWEB)

In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)

2001-07-01

170

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

171

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

172

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

173

Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).

1977-01-01

174

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and increases in FWHM ...

1998-12-01

175

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

176

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

177

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

178

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

179

Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium  

International Nuclear Information System (INIS)

Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to measure the K shell fluorescence parameters such as ...

2003-11-01

180

Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign  

Energy Technology Data Exchange (ETDEWEB)

Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers ...

2007-08-01

181

The effective per caput dose equivalent as a measure of medical radiation exposure of the population - a complement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population ...

1984-01-01

182

Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation. Report of the AAPM Radiation Therapy Committee Task Group 63  

International Nuclear Information System (INIS)

This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical ...

2003-06-01

183

Methods of selection in heavy ion collisions at Fermi energies and de-excitation modes with the INDRA multi-detector; Methodes de tri dans les collisions d'ions lourds aux energies de Fermi et modes de desexcitation avec le multidetecteur INDRA  

Energy Technology Data Exchange (ETDEWEB)

The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4{pi}, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)

2005-11-15

184

Interim cryo-cooler/detector report  

Energy Technology Data Exchange (ETDEWEB)

This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital ...

1995-04-19

185

Intensity modulated radiotherapy: advantages, limitations and future developments  

UK PubMed Central (United Kingdom)

Intensity modulated radiotherapy (IMRT) is widely used in clinical applications in developed countries, for the treatment of malignant and non-malignant diseases. This technique uses multiple radiation...Full Text Available

186

Emergency Reference Levels: Criteria for Limiting Doses to the Public in the Event of Accidental Exposure to Radiation.  

Science.gov (United States)

Recommended ERLs for whole body, thyroid, lung and other single organs are presented in tabular form, and related to the relevant counter measures such as evacuation, sheltering, distribution of stable iodine tablets, etc. Application of ERLs to local env...

1981-01-01

187

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

188

Treatment of cancer of the pancreas by intraoperative electron beam therapy: physical and biological aspects  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment ...

1989-01-01

189

Treatment of cancer of the pancreas by intraoperative electron beam therapy: physical and biological aspects  

International Nuclear Information System (INIS)

Radiation therapy has had a significant and an expanded role in the management of cancer of the pancreas during the last decade. In particular, for locally advanced disease, radiation therapy has improved the median survival of patients to 1 year. Intraoperative electron beam therapy has been applied to unresectable and resectable pancreatic cancer in an attempt to enhance local control of disease and to improve patient survival. This paper presents a survey of the role of radiation therapy in treatment of cancer of the pancreas, provides information on the radiobiological aspects of this treatment modality and details the physical and dosimetric characteristics of intraoperative radiation therapy with electrons. Presented are the design specifics of an applicator system, central axis beam data, applicator parameters, dose distribution data, shielding, treatment ...

190

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose ...

191

Reactivity surveillance experiments with the engineering mock-up core of the fast flux test facility reactor  

International Nuclear Information System (INIS)

An experiment was performed with a mock-up of the core of the Fast Flux Test Facility (FFTF) reactor to evaluate three reactivity measurement methods for application to liquid-metal fast breeder reactors (LMFBR): modified source multiplication measurements with the low-level flux monitor for refueling (35 dollars subcritical) of FFTF, noise analysis to 35 dollars subcritical, and inverse kinetics rod drop to 12 dollars subcritical. To investigate the spatial dependence of these measurement methods and to resolve discrepancies previously reported, detectors were placed in the core, reflector, and radial shield, and experimental data were collected with the reactivity at near delayed criticality to 35 dollars subcritical. Conclusions from this experiment are the following. Low-level flux monitors in the shield of the FFTF will be adequate for reactivity surveillance during refueling, using the modified source multiplication method calibrated near ...

192

Electronic system hardening methodology  

International Nuclear Information System (INIS)

The notion of hardened systems can be found in several applications (nuclear power plants, alarm systems, research installations..). Their development correspond to the functional necessity to take into account a specific radiative environment. The starting point of each hardening study is the definition of the radiative environmental constraints representative of the application. In addition to these external constraints, the specific functional characteristics of each system are considered: control or interface systems in nuclear industry, in-board control systems, remote handling systems, etc. This paper summarizes the methodology followed according to the experience gained in previous studies and anticipating the future needs. (J.S.). 6 refs., 5 figs.

193

The effect of temperature on the radiative performance of Ho-YAG thin film selective emitters  

Energy Technology Data Exchange (ETDEWEB)

The authors present the emitter efficiency results for the thin film 25 percent Ho YAG (Yttrium Aluminum Garnet, Y3Al5O12) selective emitter from 1000 to 1700 K with a platinum substrate. Spectral emittance and emissive power measurements were made (1.2 less than lambda less than 3.2 microns) and used to calculate the radiative efficiency. The radiative efficiency and power density of rare earth doped selective emitters are strongly dependent on temperature and experimental results indicate an optimum temperature (1650 K for Ho YAG) for thermophotovoltaic (TPV) applications.

1995-01-01

194

Sophisticated applications of radiation heat transfer  

International Nuclear Information System (INIS)

A large amount of energy has been consumed so far in so called matured industries such as iron and steel, oil refinery, petrochemical, ceramic, paper and pulp manufacturing and so forth. A successive stimulation on the preceding industries has to be enhanced from a technological viewpoint in order to maintain a further development based on novel and innovative technologies. In this regard, energy technology has become and will be increasingly important in a high temperature system so that the basic concept for heat transfer augmentation methods by thermal radiation is reviewed briefly in accord with the recent developments together with theoretical background and the prominent features. The heat transfer augmentation related to thermal radiation is summarized.

1987-01-01

195

Radiation safety in industrial applications  

International Nuclear Information System (INIS)

Oil and gas industry is the largest user of radioactive materials in Nigeria. They make use of radiation generators, sealed and unsealed radioactive sources.Some of these are potentially dangerous to human health and environment if not properly controlled. here is also the need to maintain control over occupational exposures to radiation, as well as to protect the public and the environment through proper management of wastes that may be radiologically hazardous. To minimize these, effective regulatory infrastructure is being put in place.For a smooth take-off of the nuclear power program, the National Nuclear Regulatory Authority and other stake holders in the nuclear industry need to start to put together licensing procedure for these.

2008-03-17

196

Radiation preservation of foods of plant origin. Part IV. Subtropical fruits: citrus, grapes, and avocados  

Energy Technology Data Exchange (ETDEWEB)

Current information on the use of ionizing radiation for improving the storage of subtropical fruits like citrus, grapes, and avocados is reviewed. The feasibility of applying radiation either alone or in combination with other physical or chemical treatments for the control of postharvest fungal diseases is considered. Irradiation effects on the physiology of the fruits as related to respiration, ethylene evolution, changes in major chemical constituents, and quality are discussed. The recent trends in the possible use of irradiation as an alternative treatment to chemical fumigants for disinfestation of citrus and avocados and the prospects for the future application of irradiation for preservation of some of these fruits are outlined. 128 references.

1986-01-01

197

Polyurethane - positioning aids in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

A simple and cheap method is described for the manufacturing of individual positioning aids made of foamed polyurethane. Some examples are given to demonstrate the applicability of these positioning aids for the irradiation of different body regions. The reproducibility of the radiation field in the head and neck area was investigated with and without positioning aid. It was proved that the field is adjusted more exactly when positioning aids are applied. The dosimetric investigations performed showed a negligible influence of foamed polyurethane on the radiation quality. So the positioning aids could be left within the radiation field when drawing the field borders.

1985-06-01

198

Stabilization of synchrotron radiation x-ray beam by MOSTAB  

International Nuclear Information System (INIS)

Monochromator stabilization (MOSTAB) is a feedback control system to stabilize an x-ray beam of synchrotron radiation. It applies a feedback voltage to a piezo electric transducer attached to a double-crystal monochromator. We developed MOSTAB modules and examined their performances using SPring-8 beamlines. The x-ray beam position stabilization using MOSTAB was realized simultaneously with the x-ray beam intensity stabilization. As an example of its application, we performed EXAFS measurement with MOSTAB. (author)

2003-05-01

199

Proton beam therapy for cancer in deep-seated organs  

Energy Technology Data Exchange (ETDEWEB)

Radiation therapy has shown definite technical improvement due to application of proton beam irradiation. Clinical results of proton beam therapy also suggested enlargement of indication ranges in radial treatment and decrease of post radiation damages of the treatment of cancers in deep-seated organs. Inprovement of result in cancer therapy could be expected by this treatment technique in the future.

1988-10-01

200

Instrument of millimetre wave radiation and its effect on malignant tumor in mice and its application in clinic  

Energy Technology Data Exchange (ETDEWEB)

An animated test is made for mice with malignant tumors irradiated by a self-made millimetre wave radiator for medical purpose. It is observed that S-180 sarcomas in mice after irradiation has been distinctly suppressed. And remarkable effects are shown through a lot of clinical practices on peptic ulcer, skin-deep ulcer, acute and chromic soft tissue injuries etc.

1995-12-31

201

Evaluation of radiation induced sesame mutants as affected by some micro nutrients  

International Nuclear Information System (INIS)

Tow experiments were carried out in 1981 and 1982 growth seasons at the greenhouse of the department of agriculture for soils and water researches, atomic energy authority, at inshas, to investigate the responses of two mutation derived lines of sesame and the local cultivar giza 25 to the application of micro nutrients. The possible effect of radiation on germination and growth of sesame seed was also studied in a separate experiment conducted in 1985 season, at inshas.

202

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

203

Reduction in radiation-induced brain injury by use of pentobarbital or lidocaine protection  

Energy Technology Data Exchange (ETDEWEB)

To determine if barbiturates would protect brain at high doses of radiation, survival rates in rats that received whole-brain x-irradiation during pentobarbital- or lidocaine-induced anesthesia were compared with those of control animals that received no medication and of animals anesthetized with ketamine. The animals were shielded so that respiratory and digestive tissues would not be damaged by the radiation. Survival rates in rats that received whole-brain irradiation as a single 7500-rad dose under pentobarbital- or lidocaine-induced anesthesia was increased from between from 0% and 20% to between 45% and 69% over the 40 days of observation compared with the other two groups (p less than 0.007). Ketamine anesthesia provided no protection. There were no notable differential effects upon non-neural tissues, suggesting that pentobarbital afforded protection through modulation of ambient neural activity during radiation ...

1990-05-01

204

Application of radiation in Bangladesh  

International Nuclear Information System (INIS)

Radiation technology offers a very wide scope for utilisation and commercial exploitation in various field. All over the world, this technology is being favourably considered for different applications like radiation sterilisation of medical products, preservation of food by controlling the physiological processes for extending shelf-life and eradication of microbial and insect pests, radiation processing of polymeric materials and treatment of sewage sludge. Bangladesh Atomic Energy Commission has taken radiation processing programmes in a big way right from its inception. This paper describes the studies carried out by various research groups in Bangladesh Atomic Energy Commission mainly using Cobalt-60 gamma radiation. The investigation covers medical sterilisation, food preservation and development and modification of polymeric materials by gamma ...

2001-03-01

205

Imaging properties of the Medipix2 system exploiting single and dual energy thresholds  

CERN Document Server

Low noise, high resolution and high dose efficiency are the common requirements for most X-ray imaging applications. Especially in medical applications the dose efficiency is a necessity for detector systems. We present the imaging performance of the Medipix2 readout chip bump bonded to a 300 mu m thick Si detector as a function of the detection threshold, a free parameter not available in conventional integrating imaging systems. Spatial resolution has been measured using the modulation transfer function (MTF) and it varies between 8.2 Ip/mm and 11.0 Ip/mm at 70%. An associated measurement of noise power spectrum (NPS) permits us to derive the detective quantum efficiency (DQE) which can be as a high as 25.5 % for a broadband incoming spectrum. The influence of charge diffusion in the sensor together with threshold variation in the readout chip is discussed. Although the Medipix2 system is used in ...

2006-01-01

206

Preparation and applications of wood-polyester composites  

International Nuclear Information System (INIS)

Optimum processing parameters were searched for the pilot-scale production of wood-polyester composites by irradiation of resin-impregnated wood material. The radiation initiation of the following systems were examined in wood and without wood matrix: methyl methacrylate, mixture of styrene and acrylonitryle, and their combination with unsaturated polyester. In the most cases the over-all rate of the complete polymerization process in wood matrix is proportional to the square root of the initiation rate. The parameters of the radiation technology of wood-polyester composites have been determined, using 260 TBq (7 kCi) "6"0Co radiation source. A pilot plant has been constructed using an underwater irradiation system of 1.85 PBq (50 kCi) "6"0Co. The successful production rate of 200 kg wood-polyester composite per day, as well as the application tests have demonstrated the technical feasibility of this ...

1982-01-01

207

Abstracts of 5. International conference 'Nuclear and Radiation Physics'  

International Nuclear Information System (INIS)

The 5-th International conference 'Nuclear and Radiation Physics' was held in Almaty (Kazakhstan) 26-29 September 2005. Besides basic problems of nuclear and solid state physics the conference paid considerable attention to applied topics important for industry and science in Kazakhstan; they include fuel and construction materials for nuclear power production, new technologies and materials for their production, materials for hydrogen power production, handling and utilization of radioactive waste, analytical methods for combating with illicit trafficking of nuclear and radioactive materials, technologies for reduction and assessment of environmental risk from radiation-hazardous materials and sites, production and application of isotopes, application of nuclear technologies in medicine and industry. On the conference more than 300 papers were presented by participants from 20 countries.

2005-09-26

208

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum ...

1998-03-01

209

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows ...

210

Simulation of Pulsed Neutron Activation using a CFD code  

International Nuclear Information System (INIS)

Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed

2008-09-14

211

On problems in trustworthy predictions of etched track parameters  

Energy Technology Data Exchange (ETDEWEB)

It is discussed here how trustworthy predictions of etched track parameters in nuclear track detection technique can be made? Problems involved in doing so are described along with discussion about their possible solutions. Arguments are presented using 5.2 MeV alpha particle track etching experiments with CR-39 detector and corresponding calculations using computer programs TRACK{sub V}ISION and TRACK{sub T}EST. Experimental and computational results in the present paper are useful for further basic research and technology applications of solid state nuclear track detection technique.

2008-10-15

212

Application of /sup 252/Cf-source driven noise analysis measurements for subcriticality of HFIR fuel elements  

Energy Technology Data Exchange (ETDEWEB)

The approach-to-critical measurements reported were for a plate-type fuel element where the height of the water moderator and side and top reflector were increased. Measurements were also performed with each of the two annuli of the fuel element to verify both the presence of boron in the fuel plates and the proper uranium loading prior to assembly of the two annuli for full submersion measurements. Measurements were also performed with detectors external to the reflector (> 15 cm of water on top, bottom, and side) for the assembled, submerged HFIR fuel element.

1983-01-01

213

Toughness of membranes applied in polymer electrolyte fuel cells  

Energy Technology Data Exchange (ETDEWEB)

Since several years we apply the radiation-grafting technique to prepare polymeric membranes for application in polymer electrolyte fuel cells (PEFCs). Our investigations presented here focus on changes in toughness of these materials after the various synthesis steps and the importance of membrane toughness for their application in PEFCs. (author) 2 figs., 4 refs.

1999-08-01

214

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

215

Characterization of wood polymer composites (WPC) as an engineering material  

International Nuclear Information System (INIS)

Radiation processed wood-polymer composites (WPC) can replace conventional wood in many industrial applications. However, for proper utilization of the composites, adequate testing and evaluation programmes are essential. The paper briefly describes the development of WPC at the Bhabha Atomic Research Centre, Bombay, and the evaluation of WPC for various applications in greater details. The various mechanical properties and their significance in overall performance of WPC are also discussed. (author).

1980-08-01

216

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

Energy Technology Data Exchange (ETDEWEB)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-15

217

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

International Nuclear Information System (INIS)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-01

218

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...

1996-12-01

219

Measurements of K-shell x-ray production cross sections and K to L and M-shell radiative vacancy transfer probabilities for Nd, Eu, Gd, Dy and Ho at excitation with 59.5 keV photons in an external magnetic field  

International Nuclear Information System (INIS)

The effect of the #+-# 0.75 T external magnetic field on the K_#alpha#_1, K_#alpha#_2, K_#beta#_'_1 and K_#beta#_'_2 x-ray production cross sections and radiative vacancy transfer probabilities from K-shell to L2 and L3 subshells and M-shell for ferromagnetic Nd, Gd and Dy and paramagnetic Eu and Ho have been investigated, using the 59.5 keV incident photons. K-shell fluorescence yields and K x-ray intensity ratios for these elements have been determined in the external magnetic field also. The K x-rays from different targets were detected using a high-resolution Si(Li) semiconductor detector. For B = 0, the present experimental results were compared with the experimental and theoretical data in the literature. The results show that K-shell fluorescence parameters such as photoionization cross section, fluorescence yield, radiation rates, vacancy transfer probabilities and spectral linewidth can change owing to the applied ...

2006-06-19

220

Applications or radiation polymerization hardening to composites  

International Nuclear Information System (INIS)

Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at high dose rate cannot ...

1976-01-01

221

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

222

Effect of ionizing radiation on the properties of PLA packaging materials  

International Nuclear Information System (INIS)

Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)

223

Intraoperative radiation therapy at the National Cancer Institute: technical innovations and dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.

1985-07-01

224

Results of radon concentration measurements in some regions of Russia  

Energy Technology Data Exchange (ETDEWEB)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal ...

1996-01-01

225

Results of radon concentration measurements in some regions of Russia  

International Nuclear Information System (INIS)

Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for ...

226

Correction for loss of track density due to overlapping track on SSNTD  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This ...

1990-06-01

227

Monte Carlo verification of point kinetics for safety analysis of nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

Monte Carlo neutron transport methods can be used to verify the applicability of point kinetics for safety analysis of nuclear reactors. KENO-NR was used to obtain the transfer function of the Advanced Neutron Source reactor and the time delay between the core power production and the external detectors, a parameter of interest to the safety systems design. The good agreement between the Monte Carlo generated transfer function and the point kinetics transfer function validates that the uncommon ANS geometry does not preclude the use of point kinetics in the frequency range that was investigated. Various features of the power spectral densities also demonstrated the applicability of point kinetics. The time delay was obtained from the cross-power spectral density (CPSD) and is {approximately}15 ms. These analyses show that frequency analysis can be used experimentally to investigate the validity of the use of point kinetics ...

1995-06-01

228
233

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the quantity of interest (the ratio of spectral ...

1980-01-01

234

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

235

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

236

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

237

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

238

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

239

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

240

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

241

Method for determining hydrogen mobility as a function of temperature in superconducting niobium cavities  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.

2008-03-11

242

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

243

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

244

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

245

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

246

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

247

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

248

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

249

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

250

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

251

Studies of the applicability of opto-electronic devices for instrumentation in high-energy physics. Progress report, June 1, 1981-May 31, 1982  

Energy Technology Data Exchange (ETDEWEB)

Instrumentation research to study the feasibility of using optical data processing techniques to solve real-time pattern recognition problems for high energy physics experiments is now in its second year. During the past year, a prototype optical processor for use in BNL Experiment 702 was conceived and designed, using test data from the experiment and simulating the optical processor in the computer. A number of technical studies have been made, mostly relating to the selection of the optical filter for the processor. Comparisons between natural and synthetic holograms, both bleached and unbleached, have been made. We conclude from these tests that the kinoform, a computer-generated phase hologram, is the optimal choice for this processor. A new method for producing the kinoform has been tried by this group with encouraging results. The optical design for the prototype processor is complete, and the required optical elements, sources, and the detector have all ...

1982-01-01

252

Quality Management for Neutron Transmutation Doping of Silicon Ingot in HANARO  

Energy Technology Data Exchange (ETDEWEB)

By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with a silicon ingot, and thus the SPND can be properly calibrated. Excellent ...

2007-10-15

253

Evaluation of performance and characteristics of neutron radiography and standardization  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the effective energy, the ...

1995-02-01

254

Cf-source-driven neutron-noise measurements of subcriticality for a 4. 95 wt% /sup 235/U-enriched uranyl fluoride solution cylinder  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of subcritical systems of fissile material, using neutron-noise power spectral density measurements in conjunction with a /sup 252/Cf source, has been tested in experiments with an aqueous solution containing uranium fluoride (4.95 wt% /sup 235/U). The kappasub(eff)-values obtained from the ratio of spectral densities G*/sub 12/G/sub 13//G/sub 11/G/sub 23/ agreed with those from break-frequency noise analysis and with bias-corrected transport theory calculations within the statistical uncertainty of the measurements. Corrections for the effects of spatial modes and source-detector locations appear to be well-understood, since measurements for a variety of source-detector positions resulted in essentially the same kappasub(eff)-values. Modal correction factors were such that ignoring them would result in higher values of kappasub(eff) than actually occur. The measurements have demonstrated the ...

1986-01-01

255

/sup 252/Cf-source-driven neutron noise analysis measurements for coupled uranium metal cylinders  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven neutron noise analysis method for obtaining the subcriticality of an assembly of fissile material from cross-power spectral densities (CPSDs) was developed to avoid some difficulties inherent in other measurement methods. This method requires measurement of frequency-dependent CPSD between a pair of detectors in or near the fissile assembly and CPSDs between these detectors and a source of correlated neutron noise from an ionization chamber containing /sup 252/Cf, also in or near the fissile assembly. Also, the auto-power spectral density of the source is required. The ratio of spectral densities is then formed and is related to the subcriticality. To date various measurements have been performed which demonstrate the usefulness of the method including measurements with single uranium metal cylinders. The experiments described here, which used coupled uranium (93.15 wt % /sup 235/U) metal cylinders separated by ...

1985-01-01

256

Radiation induced polymerization of vinyl monomers and their application for preparation of wood-polymer composites  

International Nuclear Information System (INIS)

Polymerizing effects of high energy radiation has been found suitable for preparation of wood-polymer composites. In the present work after evaluating polymer products that have been obtained by irradiation method, wood-polymer composites have been prepared by in situ polymerization of vinyl acetate, acrylic acid and acrylic acid/styrene mixture using two samples of Iranian hardwoods, Beech and Hornbeam. These woods and their composites have been tested for their physical and mechanical properties. The results have shown that chemical bonding between polymer and the cell wall component lead to better strength properties in the composites. (author).

1992-09-01

257

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

258

Integration of SPECT with CT to plan radiotherapy fields. n application to conformal irradiation for lung carcinoma  

International Nuclear Information System (INIS)

Single photon emission computed tomography (SPECT) of lung perfusions permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiations doses it used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung.

1999-04-01

259

Electrical conductivity of radiation-processed wood polymer composites  

International Nuclear Information System (INIS)

Two species of wood, viz. Haldu (Adina Cordifolia) and Jamun (Syzygium Cumini) were vacuum-impregnated with two styrene-based monomer systems and polymerized in situ with gamma radiation from a cobalt-60 source. The electrical conductivity of these specimens was determined at various polymer loadings under dry conditions, after wetting and after wet recovery as per ASTM standards. The water absorption characteristics are also presented. The results are discussed with special reference to the role of water. Potential applications are also discussed. 7 figures.

1978-01-01

260

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

261

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

262

Measuring instrument for radiometric monitoring of solids and heavy metals in water  

International Nuclear Information System (INIS)

A combination of measuring instruments, consisting of a Beta-Sedimeter and a radionuclide X-ray fluorescence instrument, is described. With the Beta-Sedimeter the C-14-radiation is measured. Through direct irradiation with photons of a Pu238-source in an ancillary irradiation chamber and energy dispersing measurement of the K- and L-radiation resp. of the excited heavy metals with the aid of a Si(Li)-semiconductor detector and a 4-channel analyzer the heavy metal concentrations of the heavy metals Zn, Cr, Ni and Pb are determined. For the determination of cadmium the indirect excitation with Am-241 and Dy-targets is described. The system produces records and operates fully automatically in a step-by-step mode with a testing cycle of 45 minutes. In connection with the process monitoring of the wastewater from a zinc plating plant during a period of 8 months the concentration of the solid material and of the metals Cr and Zn, ...

1979-01-01

263

Measurement of L X-ray fluorescence cross-sections for elements with 45 Z50 using synchrotron radiation at 8keV  

British Library Electronic Table of Contents (United Kingdom)

The L shell fluorescence cross-sections of the elements in range 45Z50 have been determined at 8keV using Synchrotron radiation. The individual L X-ray photons, Ll, La, LbI, LbII, LgI and LgII produced in the target were measured with high resolution Si(Li) detector. The experimental set-up provided a low background by using linearly polarized monoenergetic photon beam, improving the signal-to-noise ratio. The experimental cross-sections obtained in this work were compared with available experimental data from Scofield [1,2] Krause [3,4] and Scofield and Puri et al. [5,6]. These experimental values closely agree with the theoretical values calculated using Scofield and Krause data, except for the case of Lg, where values measured of this work are slighter higher.

2011-01-01

264

Assessment of the impact of the greenhouse gas emission and sink scenarios in Finland on radiative forcing and greenhouse effect  

Energy Technology Data Exchange (ETDEWEB)

The objective of this work is to study greenhouse gas emissions and sinks and their greenhouse impact as a function of time. The greenhouse impact is expressed in terms of global average radiative forcing, which measures the perturbation in the Earth`s radiation budget. Radiative forcing is calculated on the basis of the concentration changes of the greenhouse gases and the radiation absorption properties of the gases. It takes into account the relatively slow changes in the concentrations due to natural removal and transformation processes and also allows a comparison of the impact of various greenhouse gases and their possible control options as a function of time. In addition to the applications mentioned above, the anthropogenic greenhouse gas emission histories of Nordic countries have been estimated, and the radiative forcing caused by them has been ...

1996-12-31

265

Free electron laser inertial thermonuclear synthesis  

International Nuclear Information System (INIS)

The paper proposes a concept of power driver for industrial thermonuclear reactor based on inertial thermonuclear synthesis (ITS). The circuit is based on the application of free electron laser (FEL) as a energy source for thermonuclear target compression which becomes feasible due to the application of a radically new circuit of FEL-amplifier. In the project under consideration the FEL-based laser system operates on the wave length of 0.5 micrometer. The full energy of laser radiation equals 1 MJ. This energy is delivered to the target in the pulse whose length is controlled within the range of 0.1-2 ns. The laser system brightness is 4 x 10"2"2 W cm"-"2. The FEL operating pulse repetition frequency is 40 Hz, full efficiency of electricity conversion into the energy of optical radiation is 11%. 9 refs., 3 figs., 2 tabs.

266

Feasibility of optical sensing for robotics in highly radioactive environments  

International Nuclear Information System (INIS)

The application of robotics for repair, refurbishing or dismantling of nuclear installations implies eventually severe radiation resistance requirements on embarked components and subsystems. This is particularly critical when optical sensing is considered. Optoelectronic components and optical fibers are indeed quite sensitive to radiation, and without special design are rapidly out-of-operation in such an environment. This paper reports the results of a series of #gamma# irradiation experiments on such devices, and identify their behavior under radiation. Test results show that carefully selected optical fibers can keep their radiation induced attenuation lower than 0.3 dB/m even up to a total dose of 10 MGy. Temperature annealing can even lower this attenuation down to 0.1 dB/m. On the other hand, commercially available light emitting diodes and photodiodes present attenuations ...

1992-10-25

267

Native Synthetic Imaging of Smoothed Particle Hydrodynamics density fields using gridless Monte Carlo Radiative Transfer  

CERN Document Server

An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework could support a Radiative Equilibrium ...

2010-01-01

268

Fitness of equipment used for medical exposure to ionising radiation  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation ...

1992-05-01

269

Experimental and theoretical study of periodic intensity bursts in the start-up phase of a free-electron laser oscillator  

International Nuclear Information System (INIS)

In this paper experimental observations and a theoretical analysis of periodic radiation bursts and macropulse formation in the start-up phase of a free-electron laser (FEL) oscillator are presented. This microwave FEL uses a long pulse electron beam with a slowly decaying voltage. The output radiation consists of a superposition of bell-shaped macropulses, each of which is composed of a periodic sequence of short micropulses. The micropulses are separated by a cavity round-trip time. Each bell-shaped macropulse has a random start-up time and amplitude. The startup of the radiation macropulses is correlated with random current spikes on the continuous electron beam. The observed macropulse signal agrees with a theoretical calculation of the impulse response of the FEL oscillator when the shift in the FEL resonance frequency arising from the slow voltage drop of the electron beam is included in the analysis. Possible ...

270

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) elaboration of regulations concerning the ...

1988-01-01

271

Polymeric radioactive waste disposal containers: an investigation into the application of polymers vice metals to house low and intermediate level radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The research carried out in Canada in the design of containers for the disposal of radioactive waste has focussed on spent nuclear fuel, even though the quantities of other currently stored radioactive wastes are substantially greater. Research carried out at the Royal Military College of Canada on the effects of mixed fields of radiation on high polymer adhesives and composite materials has shown that some polymers are quite resistant to radiation and could well serve in the fabrication of radioactive waste disposal containers. The purpose of this research was to determine if thermoplastic polymers could be used as superior materials to replace metals in the application of low and intermediate level radioactive waste disposal containers. Polymers have the advantage that they do not corrode like metals. The experimental methods, used in this research, focused on the effects of radiation on the ...

2001-07-01

272

The year 2000 embedded systems problem to maintain the safety of nuclear installations  

International Nuclear Information System (INIS)

The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a valve, may control the flow of cooling system to reactor core. ...

1999-02-01

273

On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir  

Science.gov (United States)

Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the ...

1992-01-01

274

Non-thermal atmospheric pressure HF plasma source: generation of nitric oxide and ozone for bio-medical applications  

International Nuclear Information System (INIS)

A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the plasma source are measured using absorption spectroscopy and electro-chemical ...

2010-01-01

275

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few ...

2001-06-17

276

Synthesis of polyacrylonitrile (PAN) with different stereoregularity by urea radiation inclusion polymerization and its application to carbon fiber  

Energy Technology Data Exchange (ETDEWEB)

Application to carbon fiber started in this Year. In this paper, a spinning and calcination process are explained. Fiber was obtained by wet spinning of the PAN solution. Ten solvents were tested and the results proved that dimethyl sulfoxide (DMSO) was the best solvent. Glycerine was used as a coagulating bath. The thin fiber (10 to 50 denier) was produced under the conditions of about 20wt% concentration at about 110degC. Heat-treat temperature was about 270 to 275degC. The viscosity-tacticity relationship and T{sub sol} vs. inverse tacticity were shown in the paper. (S.Y.)

1998-01-01

277

Leachability of neutron irradiated fly ash  

Science.gov (United States)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-11-01

278

Leachability of neutron irradiated fly ash  

International Nuclear Information System (INIS)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-01-01

279

Laboratory robotics systems at the Savannah River Laboratory  

International Nuclear Information System (INIS)

Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given.

1983-11-16

280

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-01

281

INEEL Advanced Radiotherapy Research Program Annual Report 2001  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.

2002-04-30

282

Development of superconducting cryo-electron microscope and its applications  

International Nuclear Information System (INIS)

Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.).

1988-01-01

283

Depleted zinc: Properties, application, production  

Energy Technology Data Exchange (ETDEWEB)

The addition of ZnO, depleted in the Zn-64 isotope, to the water of boiling water nuclear reactors lessens the accumulation of Co-60 on the reactor interior surfaces, reduces radioactive wastes and increases the reactor service-life because of the inhibitory action of zinc on inter-granular stress corrosion cracking. To the same effect depleted zinc in the form of acetate dihydrate is used in pressurized water reactors. Gas centrifuge isotope separation method is applied for production of depleted zinc on the industrial scale. More than 20 years of depleted zinc application history demonstrates its benefits for reduction of NPP personnel radiation exposure and combating construction materials corrosion.

2009-07-15

284

Billion particle linac simulations for future light sources  

Energy Technology Data Exchange (ETDEWEB)

In this paper we report on multi-physics, multi-billion macroparticle simulation of beam transport in a free electron laser (FEL) linac for future light source applications. The simulation includes a self-consistent calculation of 3D space-charge effects, short-range geometry wakefields, longitudinal coherent synchrotron radiation (CSR) wakefields, and detailed modeling of RF acceleration and focusing. We discuss the need for and the challenges associated with such large-scale simulation. Applications to the study of the microbunching instability in an FEL linac are also presented.

2008-09-25

285

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

286

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

287

High-efficiency GaAs solar cells  

Energy Technology Data Exchange (ETDEWEB)

An updated review of the state of the art in the development of GaAs solar cells is provided, with emphasis on AlGaAs-GaAs cells suitable for space applications. A set of theoretically derived characteristics is given for this type of solar cell. Comparison of measured performance with theory shows excellent agreement. Data on the effects of radiation damage (high-energy electrons, protons, and neutrons) is also integrated into a form useful for evaluation purposes. Techniques for fabricating (AlGa)As-GaAs solar cells in quantities large enough for practical applications are discussed and are shown to have been demonstrated. The possibility of extending these techniques to the fabrication of very thin low-weight cells for space applications is also considered. Finally, the results obtained to date in the development of GaAs solar cells for applications requiring concentrated ...

1984-05-01

288

The application of the neutron time-of-flight technique for real-time diffraction studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

289

The application of the neutron time-of-flight technique for real-time diffraction studies  

International Nuclear Information System (INIS)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

290

Neutron cross-sections for next generation reactors: New data from n_TOF  

International Nuclear Information System (INIS)

In 2002, an innovative neutron time-of-flight facility started operation at CERN: n_TOF. The main characteristics that make the new facility unique are the high instantaneous neutron flux, high resolution and wide energy range. Combined with state-of-the-art detectors and data acquisition system, these features have allowed to collect high accuracy neutron cross-section data on a variety of isotopes, many of which radioactive, of interest for Nuclear Astrophysics and for applications to advanced reactor technologies. A review of the most important results on capture and fission reactions obtained so far at n_TOF is presented, together with plans for new measurements related to nuclear industry.

2008-06-22

291

Mining Knowledge in Astrophysical Massive Data Sets  

CERN Document Server

Modern scientific data mainly consist of huge datasets gathered by a very large number of techniques and stored in very diversified and often incompatible data repositories. More in general, in the e-science environment, it is considered as a critical and urgent requirement to integrate services across distributed, heterogeneous, dynamic "virtual organizations" formed by different resources within a single enterprise. In the last decade, Astronomy has become an immensely data rich field due to the evolution of detectors (plates to digital to mosaics), telescopes and space instruments. The Virtual Observatory approach consists into the federation under common standards of all astronomical archives available worldwide, as well as data analysis, data mining and data exploration applications. The main drive behind such effort being that once the infrastructure will be completed, it will allow a new type of multi-wavelength, multi-epoch science ...

2010-01-01

292

Demonstration of a Tunable-Bandwidth White Light Interferometer using Anomalous Dispersion in Atomic Vapor  

CERN Document Server

The concept of the 'white-light cavity' has recently generated considerable research interest in the context of gravitational wave detection. Cavity designs are proposed using negative (or anomalous) dispersion in an intracavity medium to make the cavity resonate over a large range of frequencies and still maintain a high cavity build-up. This paper presents the first experimental attempt and demonstration of white-light effect in a meter long ring cavity using an intracavity atomic medium. The medium's negative dispersion is caused by bi-frequency Raman gain in an atomic vapor cell. Although the white light condition was not perfectly achieved and improvements in experimental control are still desirable, significantly broad cavity response over bandwidth greater than 20 MHz has been observed. These devices will have potential applications in new generation laser interferometer gravitational wave detectors.

2006-01-01

293

Application of Vertically Integrated Electronics to Intelligent Trackers  

CERN Document Server

At Super-LHC luminosity it is expected that the standard suite of L1 triggers for CMS will saturate. Information from the tracker will be needed to reduce trigger rates to satisfy the L1 bandwidth. Tracking trigger modules which correlate information from closely-spaced sensor layers to form an on-detector momentum filter are being developed by several groups. We report on a trigger module design which utilizes three dimensional IC technology to incorporate chips which are connected both to the top and bottom sensor, providing the ability to filter information locally. A demonstration chip, the VICTR, has been submitted to the Chartered/Tezzaron two-tier 3D run coordinated by Fermilab. We report on the 3D design concept, the status of the VICTR chip and associated sensor integration utilizing oxide bonding.

2010-01-01

294

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray ...

295

Gamma and X-ray shielding compositions utilizing bauxite - Red Mud regional research laboratory (CSIR), Bhopal, India  

International Nuclear Information System (INIS)

Available in abstract form only. Full text of publication follows: The application spectrum of X-ray and Gamma radiation is increasing exponentially in the area of diagnostic, nuclear medicine, food preservation, nuclear power plants and strategic utilities. To prevent the harmful effects of these radiations, shielding materials based on lead metal and its compounds are being used historically, which are toxic in nature. To protect environment it has become necessary to develop non-toxic lead free shielding materials. The use of titanium metal and its compounds as synthetic rock i.e. SYNROC are reported to be very effective non-toxic shielding materials for various applications. Red mud waste generated in aluminum producing industries possesses a unique mineralogical compositions containing fairly high quantity of titanium oxide and iron oxide useful for making non toxic shielding compositions and ...

2007-09-02

296

Concept of malignant significant factor and its applicability for and occupational exposures  

International Nuclear Information System (INIS)

In the medical and occupational exposures, there is a tradition to use the genetically significant dose as an index of harm to the population although it only includes the genetical effects from ionizing radiations. A similar significant dose for somatic effects such as radiation leukemogenesis and carcinogenesis should be added to the genetically significant dose in order to approach an index of total harm to the population from medical and occupational exposures. For this purpose, leukemia and malignant significant factors were determined based on the induction of malignant diseases including leukemia for the atomic bombs in Hiroshima and Nagasaki and the life expectancy of individuals subject to medical examinations or treatments as well as radiation workers, taking account of the possibility of their deaths due to other diseases or accidents during a latent period of malignant diseases. The resultant significant factors ...

1980-01-01

297

Distributed radiation protection console system  

International Nuclear Information System (INIS)

Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area ...

2004-02-01

298

Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications  

International Nuclear Information System (INIS)

A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.

1996-07-15

299

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

300

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

301

Radionuclide X-ray fluorescence analysis of solid aerosol particles on Synpor 4 collection filters  

International Nuclear Information System (INIS)

The feasibility was studied of the application of radionuclide X-ray fluorescence analysis to the identification and determination of chemical elements in the air. A description of the method is presented, the main stages of the analysis are discussed (sample preparation and standards, selection of radioactive radiation sources, geometry of measurement and evaluation of results). The method is illustrated on the determination of elements Fe, Cu, Zn, Br, and Pb in air samples taken in the city of Prague. (author) 2 tabs., 2 figs., 14 refs.

1992-01-01

302

Radiation higienization possibility and perspectives  

International Nuclear Information System (INIS)

Food irradiation is the process of exposing food to an ionizing energy to kill harmful bacteria and other organisms and extend shelf-life. It is a safe process and has been approved by some 50 countries worldwide and applied commercially in the USA, Japan, China and several European countries for many years. Trends law regulations and new applications in Europe and another countries has been described. (author)

2005-09-07

303

High temperature heat transfer augmentation  

International Nuclear Information System (INIS)

The heat transfer augmentation is reviewed in view of high temperature heat exchangers illuminating the contribution of radiative heat transfer. A number of means and/or devices are presented as well as the sophisticated concept which will be promoted to the extended applications in matured industries such as iron and steel, oir refinery, petro-chemical. It should be emphasized that the more creative and innovatory technology has to be promoted in order to stimulate and refresh the foregoing industries, recognizing the increasing importance of the energy resources.

1985-08-01

304

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

305

Developing a regulatory performance assessment approach for geological disposal of spent nuclear fuel  

International Nuclear Information System (INIS)

To be able to carry out review functions regulatory authorities must be able to make critical evaluations of proponent's safety cases. In Sweden the Swedish Radiation Safety Authority aims to have in place its own suite of performance assessment tools. This paper looks at the role and application of a regulator's models to important features of current modelling in a proponent's performance assessment. (authors)

306

Decision Strategy Research: Policy Support  

Energy Technology Data Exchange (ETDEWEB)

The objective of SCK-CEN's R and D programme on decision strategy research are (1) to support and advise the Belgian authorities on specific problems concerning existing and potential hazards from exposure to ionising radiation, both in normal and emergency situations; (2) to perform research on relevant topics that might have an important impact on decision making related to nuclear applications, including social and economic sciences. Main achievements in this area in 1999 are described.

2000-07-01

307

Calculation of atomic spontaneous emission rate in 1D finite photonic crystal with defects  

CERN Document Server

We derive the expression for spontaneous emission rate in finite one-dimensional photonic crystal with arbitrary defects using the effective resonator model to describe electromagnetic field distributions in the structure. We obtain explicit formulas for contributions of different types of modes, i.e. radiation, substrate and guided modes. Formal calculations are illustrated with a few numerical examples, which demonstrate that the application of effective resonator model simplifies interpretation of results.

2009-01-01

308

Biophysical effect of microwave radiation. Biofizicheskoe deistvie SVCh-izluchenii  

Energy Technology Data Exchange (ETDEWEB)

The physical principals of the interaction between microwaves and matter are considered along with the physical-chemical mechanisms for the absorption of microwave energy by biological tissue. Consideration is given to results of studies of the effects of microwaves on cells, subcellular structures, and membranes. Medical applications of microwaves are discussed along with the development of health standards for the use of microwaves. 122 references.

1987-01-01

309

Atoms at work  

International Nuclear Information System (INIS)

This illustrated booklet describes the fission process; the use of uranium to produce power in nuclear power stations (and a brief explanation of the differences between the principal types of reactor); the formation of plutonium and fission products; radioactive wastes and their management; nuclear fusion and a conceptual fusion reactor; alpha, beta and gamma radiations; radioisotopes and their applications. (U.K.).

310

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the ...

1991-06-01

311

Application of multi-stage, multi-disk type downhole seismic source; Tadanshiki taso enbangata koseinai shingen no tekiyosei  

Energy Technology Data Exchange (ETDEWEB)

A multi-stage, multi-disk type seismic source was developed as a downhole seismic source. The seismic source is an improved version of the downhole seismic source of a system in which an elastic wave is generated by a weight accelerated by restitutive force of a spring striking the upper part of a laminated structure consisted of metal disks and elastic bodies installed in water in a well. Enhancing the vibration exciting efficiency requires impedance radiated from the disks to be increased. The multi-disk structure was adopted because of restrictions on the disk area under the limiting condition of being inside the well. Further limitation has still existed, which led to finally structuring the multi-disk type to a multi-stage construction to increase the radiated impedance. In order to increase average velocity on the radiation surface, mass relationship between the hammer and the anvil was sought so that the maximum ...

1997-05-27

312

Annual report 2005-2006  

International Nuclear Information System (INIS)

Research and development and other activities of the various constituent units of Department of Atomic Energy (DAE) and also of the institution aided by DAE for the year 2005-2006 are reported. The various constituents units of DAE consist of nuclear research centres, nuclear power stations, fuel reprocessing and heavy water plants, nuclear fuel fabrication facilities, electronic and instrumentation production organisations, atomic mineral processing units and other nuclear installations. The activities of DAE cover the whole gamut of nuclear fuel cycle, research and development in nuclear science and reactor technology, applications of radiation and radioisotopes, radiation protection, research and development in front line areas such as robotics, lasers, mathematics and computational sciences. International research collaborations like CERN-DAE collaboration were completed by BARC. These activities are described broadly ...

313

The NCRP wound model: development and application.  

Science.gov (United States)

The US National Council on Radiation Protection and Measurements, in collaboration with the International Commission on Radiological Protection, has been developing a biokinetic and dosimetric model for radionuclide-contaminated wounds. The finalised model is described briefly in this paper, together with the scientific basis and application. The multicompartment model uses first-order linear biokinetics to describe the retention and clearance of a radionuclide deposited in a wound site using seven default retention categories. Examples using plutonium nitrate in colloidal form and uranium in metal fragments show the behaviour of the less soluble forms of radionuclides in wounds, in which long-term retention is predicted. Using uranium as an example, the wound model is coupled to a uranium International Commission on Radiological Protection systemic model to predict urinary excretion patterns for different physicochemical forms of uranium. The ...

2007-08-31

314

Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report  

Energy Technology Data Exchange (ETDEWEB)

Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.

1987-01-01

315

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

316

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

317

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

318

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

319

Salmonella radicidation of poultry carcasses  

International Nuclear Information System (INIS)

This thesis reports investigations using gamma-radiation to decontaminate poultry carcasses. The application to foods of doses of ionizing radiation sufficient to reduce the number of viable specific non-sporeforming pathogenic microorganisms so that none is detectable in the treated food by any standard method is termed radicidation. The doses used in this study were at such a level that no undesirable or unfavourable side-effects occurred. The effects of these doses were studied on salmonellae and other microorganisms present in, or associated with poultry carcasses and in liquid and on solid culture media as well. Decimal reduction (D_1_0) values were estimated. These represent the dose (kGy) required to achieve a reduction in initial colony count from N_0 to 0.1 N_0. Together with the estimation of the numbers of Salmonella present per carcass the data were used to predict the effect of an ionizing ...

2005-09-22

320

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

321

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

322
323

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

324

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

325

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

326

US Photovoltaic Patents, 1988--1990  

Energy Technology Data Exchange (ETDEWEB)

This document contains US patents on terrestrial photovoltaic (PV) power applications, including systems, components, and materials, as well as manufacturing and support functions. The patent entries in this document were issued from 1988 through 1990. The entries were located by searching USPA, the data base of the US Patent Office. The final search retrieved all patents under the class Batteries, Thermoelectric and Photoelectric'' and the subclasses Photoelectric,'' Testing,'' and Applications.'' The search also located patents that contained the words photovoltaic(s)'' or solar cell(s)'' and their derivatives. A manual search of the patents in the Solar Energy Research Institute (SERI) patent file augmented the data base search. After the initial list was compiled, most of the patents on the following subjects were excluded: space ...

1991-12-01

327

US Photovoltaic Patents, 1988--1990  

Energy Technology Data Exchange (ETDEWEB)

This document contains US patents on terrestrial photovoltaic (PV) power applications, including systems, components, and materials, as well as manufacturing and support functions. The patent entries in this document were issued from 1988 through 1990. The entries were located by searching USPA, the data base of the US Patent Office. The final search retrieved all patents under the class ``Batteries, Thermoelectric and Photoelectric`` and the subclasses ``Photoelectric,`` ``Testing,`` and ``Applications.`` The search also located patents that contained the words ``photovoltaic(s)`` or ``solar cell(s)`` and their derivatives. A manual search of the patents in the Solar Energy Research Institute (SERI) patent file augmented the data base search. After the initial list was compiled, most of the patents on the following subjects were excluded: space photovoltaic technology, use of the photovoltaic effect for detectors and ...

1991-12-01

328

Triggered single-photon emission from electrically driven InP/(Al,Ga)InP quantum dots  

International Nuclear Information System (INIS)

Semiconductor quantum dots (QDs) are a promising approach to realize a single-photon source. To avoid bulky and expensive laser systems for future applications, electrical excitation is desirable. InP QDs are especially suited, as they emit in the red spectral range and therefore in the optimal range of commercial detectors. Additionally, they have been shown to be capable of emitting single photons up to 80 K. Thus, we embedded InP QDs in the intrinsic region of a p-i-n diode. To form single devices, 100 #mu#m mesas were etched and supplied with electrical contacts. We investigated the electroluminescence from single QDs and performed second-order auto correlation measurements to verify single-photon emission. To prevent expensive helium cooling and reach operation above 80 K, we investigated the influence of elevated temperature on the performance of our device. Since triggered single-photon emission is required for most ...

2010-03-21

329

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, three-dimensional computer-reconstructed neutron ...

1992-03-01

330

X-dosimetry of Tl(InS_2)_1_-_x(FeSe_2)_x single crystals  

International Nuclear Information System (INIS)

Tl(InS_2)_1_-_x(FeSe_2)_x single crystals (where x=0; 0.001; 0.005; 0.01 and 0.015) were grown by the Bridgman-Stockbarger method. Obtained single crystals were crystallized in monoclinic structure. The present paper deals with experimental results relative to X-ray dosimetric characteristics of the Tl(InS_2)_1_-_x(FeSe_2)_x solid solutions at 300 K. Installation URS-55a was the source of radiation. X-ray radiation dose (E) falling on the crystals is measured by the crystalline X-ray dosimeter DRGZ-02. The value of X-ray conductivity coefficient K_#sigma# characterising X-ray sensitivity is defined as K_#sigma#= (#sigma#_E-#sigma#_0)/E#sigma#_0. where #sigma#_E is conductivity under the effect of X-ray radiation by intensity E, #sigma#_0 is conductivity in the lack of radiation. Comparing X-ray dosimetric characteristics of TlInS_2 and Tl(InS_2)_1_-_x(FeSe_2)_x crystals notes that because of partial ...

2003-09-15

331

Radiological characterization of the GRR-1 pool  

International Nuclear Information System (INIS)

GRR-1 is a 5MW open pool type research reactor with MTR-type fuel elements cooled and moderated by light water with beryllium reflectors at the two opposing sides of the core. A graphite thermal neutron column is adjusted to one side of the core. Six radial horizontal beam tubes are available, of which three contain in-pile collimators for neutron scattering instruments. The reactor is currently out of operation for inspection and refurbishment purposes. The core has been dismantled and the fuel elements are stored in the used fuel storage tank. The GRR-1 inspection and refurbishment plan involves inspection and eventually replacement of the reactor's primary cooling circuit. The health physics procedures to be implemented during inspection of the main water outlet are divided in three stages: a) pool dose rate survey from pool top, b) pool drainage by decreasing water level in steps and c) inspection of the water main outlet. urpose of the present work is the evaluation of the gamma ...

2007-11-05

332

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations ...

1983-01-01

333

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using ...

1983-01-01

334

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a ...

1983-01-01

335

A search for. nu. sub e appearance from stopped. pi. sup + and. mu. sup + decay at LAMPF (Los Alamos Meson Physics Facility)  

Energy Technology Data Exchange (ETDEWEB)

We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the ...

1990-01-01

336

Development of fire simulation models for radiative heat transfer and probabilistic risk assessment  

Energy Technology Data Exchange (ETDEWEB)

An essential part of fire risk assessment is the analysis of fire hazards and fire propagation. In this work, models and tools for two different aspects of numerical fire simulation have been developed. The primary objectives have been firstly to investigate the possibility of exploiting state-of-the-art fire models within probabilistic fire risk assessments and secondly to develop a computationally efficient solver of thermal radiation for the Fire Dynamics Simulator (FDS) code. In the first part of the work, an engineering tool for probabilistic fire risk assessment has been developed. The tool can be used to perform Monte Carlo simulations of fires and is called the Probabilistic Fire Simulator (PFS). In Monte Carlo simulation, the simulations are repeated multiple times, covering the whole range of variability of the input parameters and thus resulting in a distribution of results covering what can be expected in reality. In practical ...

2008-07-01

337

Recent progress of the JAERI free electron laser driven by a compact superconducting RF linac  

International Nuclear Information System (INIS)

A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and distance measurement system has been newly developed, and successfully applied to ...

1997-02-28

338

Focused ion beam damage to MOS integrated circuits  

Energy Technology Data Exchange (ETDEWEB)

Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. Understanding the causes of this damage is ...

2000-05-10

339

Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was ...

1982-01-01

340

Nuclear Battery As An Alternative Source Of Direct Current Electricity  

International Nuclear Information System (INIS)

Nuclear battery produces electricity by converting radiation energy into electrical energy. Energy carried by particles emitted by a radioisotope nuclei is much higher than that released in chemical reaction. Reaction with nuclei can potentially produce electricity thousand to million times higher than that of chemical reaction. Unlike NPP that produces large scale alternating current using thermodynamic cycle such as Rankine or Brayton cycles, nuclear battery is designed like other battery or fuel cell, to produce direct current (DC). However, both battery utilize the energy or particles radiating from nuclei of a radioisotope. In this paper, several types of nuclear battery as an energy converter are discussed, including their working mechanisms and examples. Nuclear battery is potential to become a long-life power source for use in wide range of applications, including in medical areas and for instruments in remote areas ...

2000-11-01

341

Cumulative effect of X-ray radiation and inflammatory reaction on the circadian rhythm of tyrosine aminotransferase in the liver of mice  

International Nuclear Information System (INIS)

The activity of tyrosine aminotransferase (TAT) in the liver of mice subjected simultaneously to ionizing radiation and to local inflammatory process showed in the first 24 hours of the experiment statistically significant changes resulting from summation of the harmful effects of both factors. In the second 24-hour period an evident tendency was observed for return of a normal circadian rhythm of the enzyme. This points to presence of an endogenous mechanism of suppression of the manifestations of significant desynchronization of the circadian rhythm. The paper contains also a trial of mathematical analysis of changes in TAT activity in the circadian rhythm, a description and analysis or the suppression process, qualitative and quantitative determination of the phenomenon of cumulation of the effects of powerful stress factors acting on the animal organism. The obtained results were compared with the results of investigations of TAT activity changes obtained in ...

1980-01-01

342

Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women  

International Nuclear Information System (INIS)

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.

1987-01-01

343

Closed-form solutions for some metric perturbations from a closed Friedmann model and the distortion of the universe  

International Nuclear Information System (INIS)

We consider perturbations of a particular type (homogeneous of Bianchi type IX) from a closed Friedmann-Robertson-Walker model. By considering a perfect fluid, we obtain closed-form solutions for the perturbations in three interesting cases: stiff matter, radiation, and dust. As a cosmological application, we obtain an upper limit on the relative shear, (sigma/theta)_0 < b/sub 0exp/, if the microwave background radiation was last scattered at a mean red-shift element of [7,10"3] and the density parameter is #OMEGA# element of (1,10), where b/sub 0exp/ is the relative root-mean-square deviation of the temperature over the whole sky.

344

Application of microvascular free osteocutaneous flaps in the management of post-radiation recurrent oral cancer  

Energy Technology Data Exchange (ETDEWEB)

Fifty-nine patients underwent free flap osteocutaneous reconstruction that consisted of flaps of the dorsum of the foot in 26 patients and iliac crest flaps in 33 with a success rate of 92 percent and a mortality rate of 1.6 percent. These flaps, which require the expertise of microvascular surgeons, are time-consuming and complicate operating room and time management, but they represent a remarkable advance in reconstruction that can facilitate cosmetic and functional recovery of the patient. In particular, they promote healing in radiation-recurrent oral cancer and represent a definitive form of management for established radionecrosis of the mandible. The large volume of tissue available with iliac crest osteocutaneous grafts permits the management of patients with extensive cancer involving the skin, mucosa, and bone, but cancer control may still be disappointing and there is a need for improved adjuvant chemotherapy protocols. This technique appears to be a ...

1985-10-01

345

Anatomical Description of the Female Reproductive Organ and Radiation Induced Histological changes of Ovary of Melon fly, Bactrocera cucurbitae (Coq.) (Diptera: Tephritidae)  

International Nuclear Information System (INIS)

Application of gamma radiation as a physical method of disinfestations against melon flies was recognized as a potential quarantine treatment. At 50 Gy, oocytes showed degeneration one day after treatment whereas seven-day-old oocytes did not differ greatly in appearance from control groups. Abnormal enlargement of trophocyte cells and vacuolization of oocytes occurred predominantly following the treatment with 100 and 150 Gy. One day after treatment with 150 Gy trophocytes underwent hypertrophy and hyperplasia. Irradiation at 100 and 150 Gy reduced the fertility to almost zero percent in the female melon flies.(authors)

2006-06-01

346

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

347

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

348

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

349

Study of e{sup +}e{sup -}{yields}pp using initial state radiation with BABAR  

Science.gov (United States)

The e{sup +}e{sup -}{yields}pp cross section is determined over a range of pp masses, from threshold to 4.5 GeV/c{sup 2}, by studying the e{sup +}e{sup -}{yields}pp{gamma} process. The data set corresponds to an integrated luminosity of 232 fb{sup -1}, collected with the BABAR detector at the PEP-II storage ring, at an e{sup +}e{sup -} center-of-mass energy of 10.6 GeV. The mass dependence of the ratio of electric and magnetic form factors, G{sub E}/G{sub M}, is measured for pp masses below 3 GeV/c{sup 2}; its value is found to be significantly larger than 1 for masses up to 2.2 GeV/c{sup 2}. We also measure J/{psi}{yields}pp and {psi}(2S){yields}pp branching fractions and set an upper limit on Y(4260){yields}pp production and decay.

2006-01-01

350

Radon concentrations and absorbed dose measurements in a Pleistocenic cave  

International Nuclear Information System (INIS)

Radon concentration measurements were carried out using solid-state nuclear track-etch detectors (SSNTDs) type CA 80-15 cellulose nitrate films, in a Pleistocenic cave at Petralona, in Halkidiki, Northern Greece, at 55 km from the city of Thessaloniki. Radon levels as high as 88 kBqxm"-"3 (2.38 nCi x l"-"1) have been recorded inside the cave equivalent to 11.90 WL in terms of occupational exposure to radon and its decay products. Absorbed dose rates were performed using TL dosimeters, type TLD-200 (CaF_2-Dy) in a continuous monitoring program (integrated measurements). Dose rate levels as high as 110 nGy x h"-"1 were recorded inside the cave. In interpreting the high levels of radiation doses, radioactivity measurements regarding the naturally occurring "2"3"8U, "2"3"2Th and "4"0K radionuclides were carried out in various speleothems found at different sites in the cave. (author)

2003-10-01

351

Radiometric analysis of raw materials and end products in the Turkish ceramics industry  

International Nuclear Information System (INIS)

This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. The results suggest ...

2011-05-01

352

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...

2007-04-01

353

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

354

Muon trigger, flavour tagging and physics performance of the LHCb experiment; Trigger a muons, etiquetage de la saveur et performances physiques de l'experience LHCb  

Energy Technology Data Exchange (ETDEWEB)

The LHCb experiment that is being settled in CERN is dedicated to the study of CP violation and rare decays in the field of beauty hadrons. The phenomenological background necessary to an adequate understanding of the physics of flavor is presented in the first chapter, it is shown how the flavordynamics can open the way to new physics. The second chapter is dedicated to a brief presentation of the LHCb detector. Two aspects of the design of the muon trigger are more detailed: the radiation resistance of the opto-electronic transmitters and the simulated performances of the trigger. The third chapter reviews the tasks linked to the tagging of the savors of B mesons which will be an important step in all the experiments made at LHCb. The recent progress in heavy savor physics as well as the expected contribution of LHCb in this field are presented in the fourth chapter, especially the search for new physics in penguin diagrams b {yields} s.

2007-10-15

355

Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction  

International Nuclear Information System (INIS)

The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.

1981-07-01

356

Coated semiconductor devices for neutron detection  

Energy Technology Data Exchange (ETDEWEB)

A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and electrical settings, neutrons at specific ...

2002-01-01

357

An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...

1990-09-16

358

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger ...

2000-03-21

359

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

363

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

364

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

365

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...

2011-02-01

366

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

367

Radiation-hardening of magnet coils  

International Nuclear Information System (INIS)

The first essential before embarking on the radiation-hardening of electrical insulation - mostly magnet coils - in any beam line application is to obtain a reliable estimate of the dose to the components. These are examples ( switchyards at SLAC and LAMPF) where the degree of hardness specified was much higher than was required. Although experience shows that the cost premium for substantial radiation - hardening is of the order of 10%, it has also become clear that well - designed beam line have negligible losses: hardening is required only in the vicinity of targets, collimators or other beam - intercepting devices. Where the beam is deliberately scraped, local shielding will minimize the associated radiation in the surroundings. Electron machines have their own special problems due to synchrotron radiation, so certainly coils and other electrical equipment should be kept away ...

1989-03-01

368

Physics through the 1990s: scientific interfaces and technological applications  

Energy Technology Data Exchange (ETDEWEB)

The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics--biophysics, the brain, and theoretical biology; the physics-chemistry interface--instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics--tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics--complex systems and applications in basic research; mathematics--field theory and chaos; microelectronics--integrated circuits, miniaturization, future trends; optical information technologies--fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security--devices, weapons, and arms control; medical physics--radiology, ultrasonics, NMR, and photonics. An executive summary and ...

1986-01-01

369

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

370

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

371

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

372

Studies on application of radiation and radioisotopes -The application of irradiation techniques for food preservation and process improvement-  

Energy Technology Data Exchange (ETDEWEB)

The project was designed to solve the infra structural problem required for commercialization of food irradiation. In improvement of physical properties of corn starch, gamma irradiation was effective for increasing glucose productivity and for substituting traditional modified starches (acid modified starch, oxidized starch). In immobilization of microorganisms, the mass production method of natural red pigment was developed by using immobilized mold pellets. In Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield. In evaluation of wholesomeness, gamma irradiated red ginseng could be safe on the genotoxic point of view. And also, six items of irradiated foods approved for human consumption from Korea ministry of health and welfare in May 19, 1995. 30 figs, 20 tabs, 54 refs. (Author).

1995-07-01

373

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, ...

374

Geometric configuration factors for polygonal zones using Nusselt's unit sphere  

Energy Technology Data Exchange (ETDEWEB)

The Energy Laboratory of the University of Houston has developed a computer simulation program called CREAM (Cavity Radiation Exchange Analysis Model) for application to the solar central receiver system. CREAM contains a geometric configuration factor generator based on Nusselt's method. A formulation of Nusselt's method provides the basis for a FORTRAN subroutine NUSSELT. Numerical results from NUSSELT are compared to analytic values and values from Sparrow's method. Sparrow's method is based on a double contour integral and its reduction to a single integral which is a approximated by Gaussian methods. Nusselt's method is adequate for the intended engineering applications, but Sparrow's method is an order of magnitude more efficient in many situations.

1983-05-01

375

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of radiation. This justifies ...

1991-11-01

376

Laser eye protection. Interim report, July 1989-January 1990  

Energy Technology Data Exchange (ETDEWEB)

Laser applications have proliferated in recent years and, as to be expected, their presence is no longer confined to the laboratory or places where access to their radiation can be easily controlled. One obvious application where this is so is in military operations where various devices such as laser range finders, target designators, and secure communications equipment elevate the risk of exposure, specifically eye exposure, to unacceptable levels. Although the need for eye protection in the laboratory and other controlled areas has been appreciated since the invention of the laser, the use of lasers in circumstances where safety or the risk of temporary loss of vision, which can not always be ensured by administrative procedures, has made adequate eye protection essential. It is the critical nature of many military operations that has driven the search for eye protection against both nuclear and laser ...

1990-01-01

377

Using radiation: harder, tougher and more stable woods  

International Nuclear Information System (INIS)

The general characteristics of radiation processing and its main applications of interest in Chile are described, with particular reference to the production of wood-plastic composites (WPC). The process itself and the technical characteristics of the resulting product are explained for products that demand an aesthetic appearance, warmth, toughness and durability, as in the flooring industry. Certain domestic wood products could receive a boost in quality by using this process, making them more competitive in demanding export markets. These products could open new markets, serving as substitutes, for example, for carpets and tiles. This would be highly convenient for Chile, considering the big supply of wood for industrial consumption that the country will have in the coming decade. Because of this situation two Chilean technology institutes, the Chilean Nuclear Energy Commission and INTEC-CHILE, are jointly working on a project that aims to ...

1998-10-01

378

The combination therapy with hepatic arterial infusion chemotherapy and radiation therapy for unresected intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

The outcome was retrospectively examined and prognostic factors were discussed for arterial chemo-infusion therapy (ACT) through an implanted reservoir system and radiation therapy (RT) in patients with unresectable intrahepatic cholangiocarcinoma (CCC). ACT plus RT were conducted to 25 patients (mean age 61.7 y, M/F 12/13, stage III-IVB) during 10 years from 1996 to 2005 with various regimens of cisplatin (CDDP), 5- fluorouracil (FU), epirubicin (FARM), mitomycin C (MMC) plus 39-50 Gy of radiation in a fractionated manner partly involving internal RT (2 cases, 15 Gy) and RT for metastatic bone (1, 25 Gy). The survival rates at 1, 2 and 3 years after ACT+RT were respectively 52.5, 43.7 and 28.1%; total efficacy (PR) was 36% (9/25) at 6 months; and significantly good prognostic factors were found to be female and absence of metastasis remote and/or lymphatic around artery. Authors concluded that ACT+RT was a meaningful treatment for highly ...

2007-11-01

379

Sensorial effects of gamma radiation processing on cinnamon (Laurus cinnamomum) and nut meg (Myristica fragans)  

Energy Technology Data Exchange (ETDEWEB)

Food irradiation is the processing of food products by ionizing radiation in order, among other things, to control food borne pathogens, reduce microbial load and insect infestation, inhibit the germination of root crops, and extend the durable life of perishable products. Irradiation of dried food ingredients, particularly herbs and spices, has a great application potential, and has already been implemented in many countries. Spice irradiation is performed to increase the hygienic quality and used as decontamination processes instead of fumigation methods. European Community approves irradiation processing as an effective residue-free alternative. The present paper evaluates the effect of ionizing radiation on sensorial properties of cinnamon (Laurus cinnamomum) and nut meg (Myristica fragans). The samples have been irradiated in multipurpose irradiator of {sup 60}Co in the doses: 0, 5, 10, 15, 20 e 25 kGy. (author)

2007-07-01

380

Radiation methods in research of ancient monuments  

Energy Technology Data Exchange (ETDEWEB)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. ...

2000-11-15

381

Radiation methods in research of ancient monuments  

International Nuclear Information System (INIS)

A 'Laboratory of Quantitative Methods in Monument Research' is being built at the CTU Prague. Its primary orientation is the investigation of historic architecture, although other objects of art can also be investigated. In the first phase, two radiation methods are being established, but it is set up in such a way, that various other methods can readily be added in its future development. The radiation methods chosen for the initial development of the laboratory are: thermoluminescence dating and X-ray fluorescence analysis. The design of the automated TL-reader, built in our laboratories, is adjusted for the purpose of dating of historic brick architecture (which, of course, does not exclude applications for ceramics and other materials). The investigation of renaissance architecture in southern Bohemia and Moravia is under preparation as the first large campaign of this kind in the Czech Republic. Radionuclide X-ray ...

2000-11-15

382

Medicinal protection with Chinese herb-compound against radiation damage  

Energy Technology Data Exchange (ETDEWEB)

Experiments were carried out on mice and the subjects irradiated for cancer therapy to evaluate the protective efficacy of a Chinese medicinal herb-compound (CMHC). The lethality and the degree of leucopenia caused by radiation in mice medicated with CMHC were significantly less in comparison with control mice (p less than 0.01 and p less than 0.001, respectively). CMHC significantly improved the WBC and the thrombocytes in irradiated workers (p less than 0.01 and p less than 0.001, respectively). The WBC count of 40 patients under radiotherapy while treated with CMHC recovered from 3450 +/- 77/c.mm to 5425 +/- 264/c.mm (p less than 0.001); whereas, in the control group, without any medication, the WBC count dropped significantly (p less than 0.001). Our results revealed the applicabilities of CMHC in protection against radiation damage in spaceflight and in other fields.

1990-08-01

383

Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis  

International Nuclear Information System (INIS)

The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including ...

2003-06-01

384

Comparison Of Reionization Models: Radiative Transfer Simulations And Approximate, Semi-Numeric Models  

CERN Document Server

We compare the predictions of four different algorithms for the distribution of ionized gas during the Epoch of Reionization. These algorithms are all used to run a 100 Mpc/h simulation of reionization with the same initial conditions. Two of the algorithms are state-of-the-art ray-tracing radiative transfer codes that use disparate methods to calculate the ionization history. The other two algorithms are fast but more approximate schemes based on iterative application of a smoothing filter to the underlying source and density fields. We compare these algorithms' resulting ionization and 21 cm fields using several different statistical measures. The two radiative transfer schemes are in excellent agreement with each other (with the cross-correlation coefficient of the ionization fields >0.8 for k 0.6 for k < 1 h/Mpc). When used to predict the 21cm power spectrum at different times during reionization, all ionization ...

2010-01-01

385

A partitioned central solar receiver  

International Nuclear Information System (INIS)

Else of solar energy as substitute for conventional fuels at a competitive cost requires efficient conversion from solar radiation to usable forms of energy. In solar thermal or thermochemical applications, high efficiency usually re- quires high temperature and high concentration of incoming radiation. The main form of energy loss from high temperature solar central receivers is thermal emission ('re radiation'), at an effective temperature close to the maximum receiver temperature. This loss is reduced if the aperture is divided into segments, most of which are maintained at lower temperatures. A two-stage partitioned receiver demonstrating this concept is under construction at the Weizman Solar Tower. The high-temperature stage is the DIAPR (Directly Irradiated Annular Pressurized Receiver). The low-temperature stage is made of tubular cavity receivers of simpler design. Preliminary optical and ...

1996-05-01

386

The application of platinum-silicide anode layer to decrease the static and turn-off losses in high-power P-i-N diode  

Energy Technology Data Exchange (ETDEWEB)

The platinum-silicide layer was investigated as the anode contact of a high-power P-i-N diode. The thermal stability at 700 deg. C was found sufficient for the purpose of Pt in-diffusion from the platinum-silicide layer into the volume. The diffusion, which was controlled using the radiation defects resulting from the 10 MeV alpha particle irradiation, represents a new local lifetime control in the float zone silicon with very low-leakage current, while keeping the benefits of traditional approaches.

2003-06-02

387

The application of Geant4 simulation code for brachytherapy treatment  

CERN Document Server

Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

2000-01-01

388

Robotics and Automation Activities at the Savannah River Site: A Site Report for SUBWOG 39F  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site has successfully used robots, teleoperators, and remote video to reduce exposure to ionizing radiation, improve worker safety, and improve the quality of operations. Previous reports have described the use of mobile teleoperators in coping with a high level liquid waste spill, the removal of highly contaminated equipment, and the inspection of nuclear reactor vessels. This report will cover recent applications at the Savannah River, as well as systems which SRS has delivered to other DOE site customers.

1995-09-28

389

Radiological protection. Textbook for radiographers and reference book for radiological safety officers  

International Nuclear Information System (INIS)

The textbook is primarily intended for radiologic staff and radiologic safety officers and gives information on the current regulatory provisions of the German X-ray Ordinance, applications of X-rays, quality assurance, organisational aspects of film processing and quality requirements of X-rays. An annex lists the guidelines of the Bundesaerztekammer (German National Chamber of Physicians) relating to quality assurance aspects, and further useful information on commercially available film-screen systems, the various associations of physicians in Germany, and requirements and performance of radiation surveys. (vhe).

390

Overview of US LMFBR Structural Materials Mechanical Properties Program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the objective, scope, and status of the US Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented.

1983-01-01

391

Overview of U.S. LMFBR structural materials mechanical properties program  

International Nuclear Information System (INIS)

This paper presents the objective, scope, and status of the U.S. Department of Energy's Materials and Structures Program to develop a data base on mechanical properties of structural materials for out-of-core structures and components for LMFBRs. Information on the development of a reference data base on materials for the reactor system, reactor enclosure system, primary heat transport system, intermediate heat transport system, and steam generator system is included. In addition, the development of the data and analyses to account for the effects of temperature and stress, as well as water/steam, sodium, and radiation environments, is described. Plans for the development of alternative materials for future out-of-core applications are presented. (author).

1983-10-10

392

Nuclear reactor with external structure cooling by natural convection  

International Nuclear Information System (INIS)

The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.

393

New results for 5-point functions  

Energy Technology Data Exchange (ETDEWEB)

Bhabha scattering is one of the processes at the ILC where high precision data will be expected. The complete NNLO corrections include radiative loop corrections, with contributions from Feynman diagrams with five external legs. We take these diagrams as an example and discuss several features of the evaluation of pentagon diagrams. The tensor functions are usually reduced to simpler scalar functions. Here we study, as an alternative, the application of Mellin-Barnes representations to 5-point functions. There is no evidence for an improved numerical evaluation of their finite, physical parts. However, the approach gives interesting insights into the treatment of the IR- singularities. (orig.)

2007-12-15

394

Interplay between the ray and mode effects in electromagnetic behavior of small-size hemielliptic dielectric lenses  

CERN Document Server

Focusing and resonance properties of two-dimensional small-size hemielliptic lenses made of different materials are studied numerically in order to estimate the influence of internal reflections on the radiation characteristics of dielectric lens antennas. Accuracy of in-house made algorithms based on combination of geometrical and physical optics and FDTD in the analysis of optical and modal effects in the behavior of such lenses is tested by comparison with the exact solution obtained using the Muller boundary integral equations. The range of applicability for the approaches is discussed.

2010-01-01

395

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

396

Animal experiments on the biokinetics of astatide and astate-(I)-complex compounds  

International Nuclear Information System (INIS)

The radiation properties of the #alpha# emitter "2"1"1At are in favor of its application malignant tumor therapy. As a basis for further investigations the biokinetics of At"-, At x H_2O, At I_2"-, and [At(thio)_2]"+ were determined after i.v. injection into healthy and tumor-bearing mice. The estimation of the ion mobility of the carrier-free compounds allowed the use of uniquely characterized initial compounds. The organ distribution of all species examined was similar to the distribution of astatide. Accumulation was found in the thyroid and other inner organs. (author).

397

Application of the elemental contents in diet, organ or tissues and urine for Chinese adult men in radiation protection  

International Nuclear Information System (INIS)

Objective: To apply the obtained results from 3 stages of research in Chinese radiation protection field. Methods: Based on the identification of physical, chemical and biological qualities for element and its radionuclides under equilibrium condition, main application of these results in Chinese radiation protection field have been discussed by using reported methods in literature. Results: Based on developing elemental reference values of organs or tissues, whole body burdens and their distribution for Chinese Reference Man, discussed in the above 3 articles, current dietary elemental intakes of 42 elements have been updated, and related basis for certain important parameters of bio-kinetic model for use in radiation protection (for example, f_l, T_e and T_b) have been provided. The internal doses from primordial radionuclides and transfer coefficients of elements from environment into the critical ...

2007-08-01

398

The main activities and scientific collaboration possibilities at Ankara Nuclear research and training center  

International Nuclear Information System (INIS)

Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, ...

2004-10-01

399

Hydrogen analysis by p-p scattering in geological material  

International Nuclear Information System (INIS)

It has been concluded by geologists that a significant amount of hydrogen is stored as point defects in nominally anhydrous minerals. Determination of the amount of hydrogen bound in these minerals is a step towards determining the total water content of the earth mantle as well as comprehending its internal water cycle. The possibility to measure hydrogen in thin geological samples by elastic p-p scattering has been investigated at the Lund Nuclear Microprobe. In this work the development of the experimental procedure and standardisation of data analysis is described. Special emphasis has been put into doing the data analysis as simple as possible and at the same time applicable to all sorts of thin samples, even those of unknown nature. A special annular surface barrier detector composed of two insulated detector halves, which are read out simultaneously, is used to detect the recoiled proton and the scattered proton in ...

2004-06-01

400

Studies on formation and structures of ultrafine Cu precipitates in Fe-Cu model alloys for reactor pressure vessel steels using positron quantum dot confinement in the precipitates by their positron affinity. JAERI's nuclear research promotion program, H11-034 (Contract research)  

Energy Technology Data Exchange (ETDEWEB)

Positron annihilation experiments on Fe-Cu model dilute alloys of nuclear reactor pressure vessel (RPV) steels have been performed after neutron irradiation in JMTR. Nanovoids whose inner surfaces were covered by Cu atoms were clearly observed. The nanovoids transformed to ultrafine Cu precipitates by dissociating their vacancies after annealing at around 400degC. The nanovoids and the ultrafine Cu precipitates are strongly suggested to be responsible for irradiation-induced embrittlement of RPV steels. Effects of Ni, Mn and P addition on the nanovoid and Cu precipitate formations were also studied. The nanovoid formation was enhanced by Ni and P, but suppressed by Mn. The Cu precipitates after annealing around 400degC were almost free from these doping elements and hence were pure Cu in the chemical composition. Furthermore the Fermi surface of the 'embedded' Cu precipitates with a body centered cubic crystal structure was obtained from two dimensional angular ...

2003-03-01

401

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...

402

First Observation of Radiative B^0 -> \\phi K^0 \\gamma Decays and Measurements of Their Time-Dependent CP Violation  

CERN Document Server

We report the first observation of the radiative decay B^0 -> \\phi K^0 \\gamma using a data sample of 772 x 10^6 B B-bar pairs collected at the \\Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a signal of 37+/-8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is ${\\cal B}(B^0 -> \\phi K^0 \\gamma) = (2.74\\pm 0.60 \\pm 0.32) \\times 10^{-6}$, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP violation parameters: ${\\mathcal S}_{\\phi K_S^0 \\gamma} = +0.74^{+0.72}_{-1.05} (stat)^{+0.10}_{-0.24} (syst)$ and ${\\mathcal A}_{\\phi K_S^0 \\gamma} = +0.35 +/- 0.58 (stat)^{+0.23}_{-0.10} (syst)$. Furthermore, we measure ${\\mathcal B}(B^+ -> \\phi K^+ \\gamma) = (2.48 +/- 0.30 +/- 0.24) x 10^{-6}$, ${\\mathcal A}_{CP} = -0.03 +/- ...

2011-01-01

403

Protection provided by criminal law against hazards of nuclear energy and the harmful effects of ionizing radiation. Also a survey of the history of definition of offences against the atomic energy law and radiation protection law in the Federal Republic of Germany. Der strafrechtliche Schutz vor den Gefahren der Kernenergie und den schaedlichen Wirkungen ionisierender Strahlen. Zugleich eine Darstellung der historischen Entwicklung der Kernenergie- und Strahlendelikte in der Bundesrepublik Deutschland  

Energy Technology Data Exchange (ETDEWEB)

The subjects, principles and purpose of the atomic energy law and the radiation protection law are set out, and criminal offences under atomic energy law are outlined explaining the legal terminology applied. The peaceful uses of nuclear energy and radioactive materials are briefly discussed, primarily looking at the hazards involved and the protective role of criminal law principles that have been developed in connection with the atomic energy law and its application in practice. The draft version of the 16th criminal law amendment act - Act to combat environmental delinquency - is discussed, which aims at adoption of all criminal offences under atomic energy law by the Criminal Code. The book furthermore presents considerations about basic features of delinquency under atomic energy and radiation protection law, revealing elements and facts of offences defined, and particular problems resulting thereof. The question ...

1989-01-01

404

Use of a predictor for total body potassium content: application to nutrition and hypertension  

International Nuclear Information System (INIS)

Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close agreement with a predictor formula, provided higher estimates of lean body mass than did skin fold thickness, and showed no ...

405

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new set of transducers, microwave oscillators, ...

2009-09-14

406

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array  

Science.gov (United States)

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a ...

2009-03-10

407

Rotating magnetic tensor gradiometry and a superconducting implementation  

International Nuclear Information System (INIS)

This work describes the theoretical basis for a new concept rotating magnetic tensor gradiometer. The rotating gradiometer consists of an approximately axial or transverse gradiometer which is made to rotate about a perpendicular axis so that the direction of sensitivity is continually changing. It is demonstrated for the first time that the rotation separates gradient components of progressively higher-order in the frequency domain and enables absolute-value measurements of all components of the first-order magnetic gradient tensor, even if the magnetic sensors comprising the gradiometer are intrinsically incapable of absolute-value detection. In addition, the rotating gradiometer concept has a number of other advantages: the gradiometer imbalance is no longer directly determined by the engineering precision, the DC and low-frequency performance of the instrument is not limited by the performance of the detectors in these respects, rotation at frequencies above ...

2009-07-01

408

Proposal for a High Energy Nuclear Database  

Energy Technology Data Exchange (ETDEWEB)

The authors propose to develop a high-energy heavy-ion experimental database and make it accessible to the scientific community through an on-line interface. This database will be searchable and cross-indexed with relevant publications, including published detector descriptions. Since this database will be a community resource, it requires the high-energy nuclear physics community's financial and manpower support. This database should eventually contain all published data from Bevalac, AGS and SPS to RHIC and CERN-LHC energies, proton-proton to nucleus-nucleus collisions as well as other relevant systems, and all measured observables. Such a database would have tremendous scientific payoff as it makes systematic studies easier and allows simpler benchmarking of theoretical models to a broad range of old and new experiments. Furthermore, there is a growing need for compilations of high-energy nuclear data for applications including ...

2005-03-31

409

Effect of Infrared Pulsated Laser on the Dielectric Properties of Makrofol Polycarbonate  

International Nuclear Information System (INIS)

Makrofol-De 1-1 CC Polycarbonate is a class of polymeric solid state nuclear track detectors which has many applications in various industrial fields. A study of the modification possibility of the dielectric properties of Makrofol polymer using laser irradiation has been carried out. In tbe present work, Makrofol samples were irradiated using different fluences between 0.47 and 10.4 J/cm"2 of 5 watt infrared pulsated laser. The mollifications in the laser irradiated Makrofol samples have been studied as a function of fluence using dielectric constant #epsilon#', dielectric loss #epsilon#"and AC conductivity #sigma#_AC measurements. Tbe frequency dependencies (100 Hz-5 MHz) of #epsilon#', #epsilon#"and #sigma#_AC at 35 degree c were investigated. The dielectric constant #epsilon#', dielectric loss #epsilon#"and AC conductivity #sigma#_AC were found to increase at heating up to 100 degree C. This indicates that #epsilon#', #epsilon#"#sigma#_AC ...

410

Detection system characteristics using sup 252 Cf ionization chambers  

Energy Technology Data Exchange (ETDEWEB)

Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine ...

1990-01-01

411

Application of passive and active methods parallel to the measurements of local climatic parameters for the assessment of Rn-222 behaviour in selected Swiss dwellings  

International Nuclear Information System (INIS)

Sources of radon and pathways in which radon can reach dwelling-rooms are shortly discussed. In continuation of the previous measurements of radon in Swiss dwellings with track detectors and working level monitors, a complementary passive method for radon concentration measurements indoors and radon exhalation rate measurements from walls and soil surfaces is introduced. Radon decay products concentrations, air temperature gradients and wind velocities were measured continuously in four Swiss dwellings during several weeks in autumn and winter of 1985/86. The Rn-222 concentrations indoors ranged from about 10 Bq/m"3 in two houses in the Eastern Jura up to more than 23,000 Bq/m"3 in two houses situated in the Central Alps. Indoor equilibrium factors between 0.1 up to 0.5 with distinct dependences on floor-levels have been found. The influence of the temperature gradient between the oudoor and indoor air on the indoor radon daughter concentration has been determined. ...

412

Application of imaging plate technology for NDT; Imaging plate gijutsu to sono oyo  

Energy Technology Data Exchange (ETDEWEB)

This paper describes Fuji computed radiography (FCR) of Fuji Film for NDT (non-destructive testing). Imaging plate (IP) is a two-dimensional detector of X-ray, and shows higher photographic sensitivity than X-ray film. The output emission of IP provides a good linear relationship to X-ray intensity in a wide intensity range. When this emission can be digitized, the X-ray intensity can be also digitized. IP is applied to NDT as an inspection using X-ray. FCR provides higher photographic sensitivity than the conventional X-ray film method, which results in one-fifth to one-twentieth of irradiation time. Images with stable density can be obtained independent of the intensity. Since IP has a wide dynamic range, the variation of X-ray intensity of 1:500 can be expressed in a single image by single shot. High density record including 1000 images can be done using a 5.25 inch optical disk through the digital image processing and the electrical quantification. The ...

1998-10-01

413

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

415
416

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

417

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for ...

2009-08-01

418

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

419

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end ...

2007-08-21

420

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end ...

2007-08-21

421

Measurement of the charge asymmetry in top-antitop quark production with the CDF II experiment  

Energy Technology Data Exchange (ETDEWEB)

The Fermi National Laboratory (Fermilab) operates the Tevatron proton-antiproton collider at a center-of-mass energy of {radical}s = 1.96 TeV, the is therefore the only collider which is today able to produce the heaviest known particle, the top quark. The top quark was discovered at the Tevatron by the CDF and D0 collaborations in 1995. At the Tevatron, most top quarks are produced via the strong interaction, whereby quark-antiquark annihilation dominates with 85%, and gluon fusion contributes with 15%. Considering next-to-leading order (NLO) contributions in the cross section of top-antitop quark production, leads to a slight positive asymmetry in the differential distribution of the production angle {alpha} of the top quarks. This asymmetry is due to the interference of certain NLO contributions. The charge asymmetry A in the cosine of {alpha} is predicted [14] to amount to 4-6%. Information about the partonic rest frame, necessary for a measurement of A in the observable cos ...

2006-12-01

422

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone convolution ...

2007-05-01

423

Validation of the 3D finite element transport theory code EVENT for shielding applications  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the validation of the 3D deterministic neutral-particle transport theory code EVENT for shielding applications. The code is based on the finite element-spherical harmonics (FE-P{sub N}) method which has been extensively developed over the last decade. A general multi-group, anisotropic scattering formalism enables the code to address realistic steady state and time dependent, multi-dimensional coupled neutron/gamma radiation transport problems involving high scattering and deep penetration alike. The powerful geometrical flexibility and competitive computational effort makes the code an attractive tool for shielding applications. In recognition of this, EVENT is currently in the process of being adopted by the UK nuclear industry. The theory behind EVENT is described and its numerical implementation is outlined. Numerical results obtained by the code are compared with predictions of the Monte ...

2000-03-01

424

Validation and verification of the ORNL Monte Carlo codes for nuclear safety analysis  

International Nuclear Information System (INIS)

The process of ensuring the quality of computer codes can be very time consuming and expensive. The Oak Ridge National Laboratory (ORNL) Monte Carlo codes all predate the existence of quality assurance (QA) standards and configuration control. The number of person-years and the amount of money spent on code development make it impossible to adhere strictly to all the current requirements. At ORNL, the Nuclear Engineering Applications Section of the Computing Applications Division is responsible for the development, maintenance, and application of the Monte Carlo codes MORSE and KENO. The KENO code is used for doing criticality analyses; the MORSE code, which has two official versions, CGA and SGC, is used for radiation transport analyses. Because KENO and MORSE were very thoroughly checked out over the many years of extensive use both in the United States and in the international community, the existing ...

1993-11-14

425

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive ...

2002-12-01

426

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

427

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

428

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

429

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

430

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

431

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

432

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

433

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

434

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

435

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

436

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

437

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

439

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

440

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

441

Detection of high-frequency radiation sources during the 2004 Parkfield earthquake by a matched filter analysis  

Science.gov (United States)

Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and ...

2009-12-01

442

Effect of elevated temperatures on the performance of an InP cell illuminated by a selective emitter  

Energy Technology Data Exchange (ETDEWEB)

The thermophotovoltaic (TPV) option was not selected for further deep space mission technology development in NASA for several reasons. Chief among them was the large radiator required to keep the photovoltaic cells at a sufficiently low operating temperature. This led to significant integration problems with the spacecraft and limited sensor view angles. It is clear that the issue of cell temperature is crucial for space applications because of radiator size and system impact. Many efforts have focused on matching cell band gap to appropriate emitters in the 1 to 2 {mu}m range, resulting in band gaps in the 0.5 to 0.8 eV range. However, low band gaps lead to low open circuit voltages ({approximately}0.25 to 0.45 V) caused by high intrinsic carrier concentrations (n{sub i}{sup 2}). Thus, in order to obtain high performance. Photovoltaic cell temperatures must be kept near room temperature. This leads to the inevitable ...

1999-03-01

443

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

444

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

446

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

448

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

449

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

450

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

451

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

452

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

453

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

454

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

455

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

456

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

457

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

458

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

459

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...

2009-07-23

460

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

461

Joint Thesaurus. Part I (A-L) + Part II (M-Z)  

International Nuclear Information System (INIS)

This is the 1st revision of the INIS/ETDE Joint Thesaurus. It contains 20 953 valid descriptors and 8 600 forbidden terms. It was last updated in December 2003. The Joint Thesaurus contains the controlled terminology for indexing all information within the subject scope of both INIS (International Nuclear Information System) and ETDE (Energy Technology Data Exchange) information systems. The terminology is intended for use in subject description for input or retrieval of information in those systems. The thesaurus is a terminological control device used in translating from the natural language of documents, indexers or users into a more constrained system language It is also a controlled and dynamic vocabulary of semantically and generically related terms which covers a specific domain of knowledge. The domain of knowledge covered by this Thesaurus includes physics (in particular, plasma physics, atomic and molecular physics, and especially nuclear and high-energy physics), chemistry, ...

1998-05-01

462

Effective equivalent dose and radiation risk in radionuclide diagnostics estimated in patients of the Nuclear Medicine Department of the Medical Academy 'Carl Gustav Carus' Dresden  

International Nuclear Information System (INIS)

7,959 patients were examined by radionuclide in-vivo methods within one year, 1,228 of them by application of "1"3"1I-iodide (radioiodine test and scintigraphy of the thyroid gland). In compliance with the ICRP publications 26 and 27 the somatically effective equivalent dose H/sub s,eff/ was ascertained for several examining methods, derived from it the collective dose S/sub s,eff/ and considering a part of manifestation resulting from the age distribution of patients, the somatic risk regarding radiation-induced malignoma with fatal termination. For the patients examined by "1"3"1I-iodide the collective dose was 79.9 man x Sv and the mean somatic risk 30 x 10"-"5 with a part of manifestation of 0.39 accordig to 0.37 radiation-induced malignomas with fatal termination. For all patients examined by other radiopharmaceuticals the collective dose was 14.07 man x Sv, the mean somatic risk 1.7 x 10"-"5 according to 0.11 ...

1986-01-01

463

Geology, public policy, and the North Carolina low level radioactive waste (LLRW) disposal facility project  

Energy Technology Data Exchange (ETDEWEB)

North Carolina is in the process of siting a LLRW disposal facility as the next host state for the Southwest Compact. After two years of site characterization studies at two technically challenging sites, the LLRW Management Authority (the Authority), will submit a license application for the preferred site. One potential site is in unconsolidated Tertiary and Cretaceous deposits of the inner Coastal Plain, the other in fractured sedimentary rocks of the Triassic Deep River Basin. Involved since 1986, the North Carolina Geological Survey (NCGS) provides technical advice to the Division of radiation Protection, the state regulatory agency authorized to approve or deny a license. With the multi-million dollar project behind schedule, and millions of dollars over budget, in February 1992 the Southeast Compact Commission established three project milestones (1) submit license application by December 31, 1993; (2) approve ...

1994-03-01

464

General fundamentals of radiological diagnostics. Specific diagnostic radiology: Throat, mediastinum, diaphragm, mammary gland, infant thorax. 7. rev. ed.  

International Nuclear Information System (INIS)

The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR ...

465

Coherence and statistical properties of photon beams with application to the free-electron laser  

International Nuclear Information System (INIS)

The subject of quantum optics has undergone considerable development in the last twenty-five years. Spurred by the invention of the laser, the theoretical understanding of the coherence and statistical properties of optical beams has now attained a stage of maturity where it is possible to treat different kinds of light sources. Over approximately the latter half of this period of development in quantum optics, the free-electron laser (FEL) has been developed to the point where it is now regarded as a tunable light source of considerable versatility, with prospects of producing radiation over a wide range of wavelengths at large levels of power. Since the basic mechanism for radiation gain in an FEL can be understood in classical terms, much of the literature on the subject does not need to venture outside the domain of classical physics. However, it is natural that the coherence and statistical properties of photon beams produced by FEL's ...

466

Modern Formal Methods and Applications  

CERN Document Server

Modern Formal Methods and Applications

2006-01-01

467

Recycling of waste polymeric materials using ionizing radiation techniques for possible applications and practical uses  

International Nuclear Information System (INIS)

recycling of waste polypropylene (WPP) and waste rubber (WR) originated from rejected worn-out tires present very important problem due to their huge amount and their negative impact on environment. many communities in the world are struggling with this problem of how to manage waste disposal, in order to eliminate or reduce waste rubber from the environment and to reduce costs of some rubber and polypropylene articles. trials to reuse waste rubber and waste polypropylene, have encountered some difficulties.such two substrate polymers differ from each other in nature, since waste polypropylene is thermoplastic while waste rubber exists in thermosetting state. accordingly, the study and use of their mixtures should be very interesting.the aim of this work is to modify the physical and chemical properties of WR and WPP each in the form of powder (120,80 mech size), through a trial to graft some vinyl comonomers onto their surfaces using gamma radiation

2007-01-01

468

New neutron simulation capabilities provided by the Sandia Pulse Reactor (SPR-III) and the Upgraded Annular Core Pulse Reactor (ACPR)  

Science.gov (United States)

The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which enhances the neutron exposure capabilities over those of the former ACPR Facility.

1978-07-01

469

Microclimatic conditions at the external surface of building envelopes  

Energy Technology Data Exchange (ETDEWEB)

The project is described, the motivation for the research and the microclimate is defined in relation to both building physics research and applications. Air temperatur, air humidity, solar radiation and air velocity are briefly considered, whilst driving rain and long-wave radiation are described in more detail. Convective heat transfer and surface coefficients are discussed, although they are not microclimatic factors, merely resulting from combinations of such factors. They are included as they are important in relation to transfer of heat and moisture at the surface of the building envelope. Driving rain measurement is the main area of interest, including development of measurement equipment. Long-wave irradiation is measured and compared with empirical formulae from the literature. Window convection heat transfer is another main area of interest. Nocturnal convective heat transfer from a double pane glazing is studied ...

1998-12-31

470

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...

471

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

Energy Technology Data Exchange (ETDEWEB)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 [approx] 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both ...

1992-10-01

472

Life evaluation of insulating materials for electric cable by accelerated thermal-radiation combined aging  

International Nuclear Information System (INIS)

Radiation-and-thermal-combined degradation of ethylene-propylene rubber (EP rubber) and chlorosulfonated polyethylene (CSM) as cable insulating and jacketing materials were evaluated by accelerated aging tests and a method to assess the lifetime of these materials under practical application was studied. EP rubber and CSM of experimental formulation were degraded at accelerated rates, that are 50 #approx# 1000 times the degradation rate under a standard condition (1Gy/h, 50degC). The degradation was investigated by measuring the tensile properties. In the accelerated aging tests, rates of elongation decrease owing to degradation for both EP rubber and CSM were in proportion to increase in accelerated rate. Behaviors of elongation changes showed little difference with accelerated rate. EP rubber lifetime estimated from sequential aging test had a tendency to extend beyond that from simultaneous aging test, while CSM lifetime estimated from both ...

1992-01-01

473

Experimental study of the premixed combustion within the nonhomogeneous porous ceramic media  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation of premixed methane-air combustion within the one-dimensional porous ceramic burners for various burner configurations is presented. The burner is nonhomogeneous because of different pore size ceramic block used in different section of the burner. Therefore, the thermophysical and transport properties are nonuniform along the burner core length. The burners are constructed of partially stabilized zirconia. The CO and NO{sub x} emissions, flame speed, and flame stability are examined and compared at lean equivalence ratios for five different burner configurations. The sandwich-structured burner has very favorable flame stabilizing characteristic due to the radiation reflecting region. While the combustion proceeds at faster rate than other burner configurations, the radiation reflecting region and the exit surface have low temperature. Thus the NO{sub x} emission can be kept at the same low level as the other burner ...

1996-12-01

474

Broad-band stigmatic spectrograph for the soft x-ray range  

International Nuclear Information System (INIS)

We describe a panoramic stigmatic spectrograph comprising a grazing-incidence toroidal mirror and a large-aperture free-standing transmission diffraction grating (5000 lines mm-1 ). Two spectrograph versions were constructed, with grazing angles of 7.6 and 40 and the short-wavelength spectral limits near 4 and 1.5 nm. The spectrograph aberrations were studied by numerical ray tracing. The spectrograph was used to record line and quasi-continuous spectra (1.5 - 30 nm) of multiply charged ions in a plasma generated by the second-harmonic pulses of an yttrium aluminate laser (Q = 0.15 J, ? = 5 ns, ? = 0.54 ?m, repetition rate = 0.5 Hz). In combination with a laser-produced plasma radiation source, the arrangement was used to characterise soft x-ray optical components and to generate collimated beams of polarised radiation in the 14 - 20 nm range. (laser applications and other topics in quantum electronics)

1998-09-30

475

Advances in beam physics and technology: Colliders of the future  

International Nuclear Information System (INIS)

Beams may be viewed as directed and focussed flow of energy and information, carried by particles and electromagnetic radiation fields (ie, photons). Often, they interact with each other (eg, in high energy colliders) or with other forms of matter (eg, in fixed targets, sychrotron radiation, neutron scattering, laser chemistry/physics, medical therapy, etc.). The whole art and science of beams revolve around the fundamental quest for, and ultimate implementation of, mechanisms of production, storage, control and observation of beams -- always directed towards studies of the basic structures and processes of the natural world and various practical applications. Tremendous progress has been made in all aspects of beam physics and technology in the last decades -- nonlinear dynamics, superconducting magnets and rf cavities, beam instrumentation and control, novel concepts and collider praradigms, to name a few. We illustrate ...

1994-11-14

476

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation of the TOF mass spectrometer for the detection of highly ...

2006-12-21

477

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross section is a well known standard one. The ...

1997-07-01

478

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

479

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

480

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

481

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

482

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

483

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

484

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

1991-09-01

485

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

486

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

487

Application of passive type radon detectors to find fissures in banks caused by the southern Hyogo prefectural earthquake in Japan  

International Nuclear Information System (INIS)

Innumerable fissures were formed widely in Hanshin area in Japan by the former southern Hyogo prefectural earthquake occurred on Jan.17, 1995. In this study, as a preliminary investigation, we applied passive type radon detector Pico-Rad (U.S. Packard Instrument Co. Ltd.) with hemispheric plastic cover over them around the fissure along on the bank of two reservoirs to examine whether there is possibility to find fissures using the characteristics of "2"2"2Rn migration. One of the reservoir, Taniyamakami-ike, is located at the north of the Awaji-shima island at a distance of about 4 km from the seismic center of this earthquake. On the whole, "2"2"2Rn exhalation rates were high on a line of 2 m below the edge of the bank and got lower in proportion to the distance from this line. Those top of the bank had middle values among the lines. The mean "2"2"2Rn exhalation rate was 4.7 mBq m"-"2 s"-"1, and in these data we found some singularly high "2"2"2Rn points. The ...

488

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

489

The radon therapy - radon inhalatorium in Kowary  

International Nuclear Information System (INIS)

In this paper the measurements of radon-222 concentration in the air of Kowary Radon Inhalatorium in the vicinity of Jelenia Gora, Lower Silesia, Poland, performed by Radiation Protection and Radiobiology Department of National Institute of Hygiene in Warsaw, have been presented. For the measurements the integration method with the application of charcoal canisters have been used. The radon concentration was found within the very broad ranges from about 4 to 420 kBq m"-"3 depending of the season of the year. Basing on the radon concentration measurements during the inhalation therapy session and taking into account the equilibrium factor of 0.8 the doses to the bronchi of the patients in range from 1.2 to about 204 mSv (0.12-20.4 rem) have been assessed. The majority of patients (ca. 76%) received the doses between 115 and 204 mSv. (author)

490

The duke XUV FEL storage ring facility  

Energy Technology Data Exchange (ETDEWEB)

In this paper we present status and developments of the Duke storage ring facility. The Duke storage ring facility provides the unique combination of phase-locked light sources ranging from high power OK-4 XUV FEL to quasimonochromatic {gamma}-ray beam and IR/X-ray spontaneous radiation. The XUV OK-4 FEL, which is collaborative project with BlNP, Novosibirsk, is in operation since November, 1996. The OK-4 UV FEL is also used for production of nearly monochromatic {gamma}-ray s with tunable energy. We present the results of UV lasing with the OK4 FEL and selected results of its applications. We will discuss our future plans for extension of this source and status of the construction of dedicated used facility adjacent to the FEL building. (author)

1998-11-01

491

SRS conversion of XeCl laser radiation into shifted Stokes components  

International Nuclear Information System (INIS)

An experimental study and a theoretical simulation were made of stimulated Raman scattering (SRS) conversion into shifted components. It was found that there were optimal values of the pressure and focal distance for conversion into the first 'blue' satellite of the first Stokes component. A study was made of the spatial and temporal dynamics of SRS conversion, which took into account generation of the shifted components. It was demonstrated theoretically and experimentally that the satellite intensity could be enhanced significantly by additional electron-collision excitation of the vibrational levels in the conversion medium or by the application of pairs of pump pulses. The maximum efficiency of conversion to the first 'blue' satellite of the first Stokes component was 10% and the satellite intensity reached one-third of the intensity of the main Stokes line. (nonlinear optical phenomena and devices)

1998-01-31

492

Preliminary performance assessment for the Waste Isolation Pilot Plant, December 1992. Volume 1, Third comparison with 40 CFR 191, Subpart B  

Energy Technology Data Exchange (ETDEWEB)

Before disposing of transuranic radioactive wastes in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments of the WIPP for the DOE to provide interim guidance while preparing for final compliance evaluations. This volume contains an overview of WIPP performance assessment and a preliminary comparison with the long-term requirements of the Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B).

1992-12-01

493

Improvement on Liquid Radioactive Waste Treatment System of Nuclear Power Plant By Applying Ion Exchange Method  

International Nuclear Information System (INIS)

Liquid radioactive waste treatment method of using evaporator was widely used from Kori 1 to Uljin 3 and 4, but a liquid radioactive waste treatment equipment that uses an ion exchange method instead of an evaporator was adopted aiming to minimize amount of radioactive waste and radiation exposure. However, the same equipment was introduced and applied for the first time in Korea and had experienced difficulties in securing credibility for the equipment and handling of liquid radioactive waste with inadequate data about performance and experience in operation and maintenance. In this study, examination, application and effect analysis was performed on the optimization measure for handling liquid radioactive waste of Yonggwang Nuclear Power Unit 5 and 6(YGN 5 and 6) that applies an ion exchange method

2010-10-01

494

Environmental surveillance at Hanford for CY-1979  

Energy Technology Data Exchange (ETDEWEB)

Environmental data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, beef, eggs, poultry, and produce) and wildlife (deer, fish, and game birds), as well as soil and vegetation samples. In general, offsite levels of radionuclides attributable to Hanford operations during 1979 were indistinguishable from background levels. The data are summarized in the following highlights. Air quality measurements of NO/sub 2/ in the vicinity of the Hanford Site and releases of SO/sub 2/ onsite were well within the applicable federal and state standards. Particulate air concentrations exceed the standards primarily because of agricultural activities in the area. Discharges of waste water from Hanford facilities in the Columbia River under the National Pollution Discharge Elimination System (NPDES) permit were all within the parameter limits on the permit.

1980-04-01

495

Einstein's fluctuation formula. A historical overview  

CERN Document Server

A historical overview is given on the basic results which appeared by the year 1926 concerning Einstein's fluctuation formula of black-body radiation, in the context of light-quanta and wave-particle duality. On the basis of the original publications (from Planck's derivation of the black-body spectrum and Einstein's introduction of the photons up to the results of Born, Heisenberg and Jordan on the quantization of a continuum) a comparative study is presented on the first line of thoughts that led to the concept of quanta. The nature of the particle-like fluctuations and the wave-like fluctuations are analysed by using several approaches. With the help of the classical probability theory, it is shown that the infinite divisibility of the Bose distribution leads to the new concept of classical poissonian photo-multiplets or to the binary photo-multiplets of fermionic character. As an application, Einstein's fluctuation formula is derived as a ...

2006-01-01